{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:12037"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:12037","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Development of Methods for Assessment of the Effects of Sterilisation on Acellular Vascular Grafts","abstract":"Cardiovascular disease is the highest cause of morbidity worldwide, encompassing blood vessel disorders such as coronary artery and peripheral arterial disease. For small diameter applications (less than 6 mm) a tissue engineered commercial product is yet to be produced. Previously, a process for the production of acellular porcine carotid arteries was developed which showed excellent potential for clinical translation as vascular bypass grafts. Medical products, however, need to be sterilised to a sterility assurance level of 10-6 before they can be used clinically. The aim of this thesis was firstly to produce acellular vascular grafts from porcine carotid arteries using previously developed decellularisation technology. Secondly, to develop robust methods capable of evaluating the effects of different sterilisation methods on the biological and mechanical characteristics of acellular vascular grafts and finally to determine the compatibility of the main stream industrially available sterilisation processes (Gamma and E-Beam irradiation and ethylene oxide treatment) with acellular vascular grafts. Decellularisation of porcine carotid arteries was evaluated by determination of DNA content and histology. Biocompatibility was assessed using contact cytotoxicity. Acellular arteries were then subjected to 30 kGy (25 kGy min) E-Beam or Gamma irradiation or ethylene oxide treatment. The effects of sterilisation were determined using histology, immunohistochemistry, second harmonic generation multiphoton imaging, differential scanning calorimetry, denatured collagen content and determination of mechanical properties compared to non-sterilised acellular arteries. Mechanical properties were assessed using uniaxial tensile testing at a low strain rate to failure and burst pressure and compliance testing Histologically, the architecture of the arteries was retained post decellularisation and DNA content was reduced by greater than 95 %. The arteries were not cytotoxic. Stress strain mechanics were also retained but compliance testing showed a significant reduction. Post sterilisation with both Gamma irradiation and E-beam irradiation, there was a significantly increased stiffness of the elastin and collagen modulus of the acellular arteries. Ethylene oxide treatment significantly increased the elastin and collagen modulus. E-Beam irradiation and ethylene oxide treatment reduced compliance excessively. Histology showed the architecture of gamma and E-beam sterilised arteries to be consistent with acellular arteries and that ethylene oxide treated arteries exhibited some layer separation. Multiphoton imaging showed damage to all sterilised samples with Gamma sterilised acellular arteries the least affected. There were no significant differences in denaturation temperature. These results were in partial agreement with previously reported data on the effects of Gamma and E-beam sterilisation on tendons. Gamma, E-beam [30 kGy] irradiation and ethylene oxide treatment caused detrimental effects to the mechanical properties of acellular porcine carotid arteries. E-beam irradiation and ethylene oxide treatment caused severe reduction in the compliance of acellular porcine carotid arteries. Compliance mismatch is a known failure mechanism of vascular grafts, therefore E-Beam irradiation and ethylene oxide treatment were not compatible with acellular vascular grafts. Gamma irradiation caused the least damaging effects and is the most likely candidate of the three that could potentially be optimised for sterilising acellular vascular grafts.","abstract_html":"Cardiovascular disease is the highest cause of morbidity worldwide, encompassing blood vessel disorders such as coronary artery and peripheral arterial disease. For small diameter applications (less than 6 mm) a tissue engineered commercial product is yet to be produced. Previously, a process for the production of acellular porcine carotid arteries was developed which showed excellent potential for clinical translation as vascular bypass grafts. Medical products, however, need to be sterilised to a sterility assurance level of 10-6 before they can be used clinically. The aim of this thesis was firstly to produce acellular vascular grafts from porcine carotid arteries using previously developed decellularisation technology. Secondly, to develop robust methods capable of evaluating the effects of different sterilisation methods on the biological and mechanical characteristics of acellular vascular grafts and finally to determine the compatibility of the main stream industrially available sterilisation processes (Gamma and E-Beam irradiation and ethylene oxide treatment) with acellular vascular grafts. Decellularisation of porcine carotid arteries was evaluated by determination of DNA content and histology. Biocompatibility was assessed using contact cytotoxicity. Acellular arteries were then subjected to 30 kGy (25 kGy min) E-Beam or Gamma irradiation or ethylene oxide treatment. The effects of sterilisation were determined using histology, immunohistochemistry, second harmonic generation multiphoton imaging, differential scanning calorimetry, denatured collagen content and determination of mechanical properties compared to non-sterilised acellular arteries. Mechanical properties were assessed using uniaxial tensile testing at a low strain rate to failure and burst pressure and compliance testing Histologically, the architecture of the arteries was retained post decellularisation and DNA content was reduced by greater than 95 %. The arteries were not cytotoxic. Stress strain mechanics were also retained but compliance testing showed a significant reduction. Post sterilisation with both Gamma irradiation and E-beam irradiation, there was a significantly increased stiffness of the elastin and collagen modulus of the acellular arteries. Ethylene oxide treatment significantly increased the elastin and collagen modulus. E-Beam irradiation and ethylene oxide treatment reduced compliance excessively. Histology showed the architecture of gamma and E-beam sterilised arteries to be consistent with acellular arteries and that ethylene oxide treated arteries exhibited some layer separation. Multiphoton imaging showed damage to all sterilised samples with Gamma sterilised acellular arteries the least affected. There were no significant differences in denaturation temperature. These results were in partial agreement with previously reported data on the effects of Gamma and E-beam sterilisation on tendons. Gamma, E-beam [30 kGy] irradiation and ethylene oxide treatment caused detrimental effects to the mechanical properties of acellular porcine carotid arteries. E-beam irradiation and ethylene oxide treatment caused severe reduction in the compliance of acellular porcine carotid arteries. Compliance mismatch is a known failure mechanism of vascular grafts, therefore E-Beam irradiation and ethylene oxide treatment were not compatible with acellular vascular grafts. Gamma irradiation caused the least damaging effects and is the most likely candidate of the three that could potentially be optimised for sterilising acellular vascular grafts.","abstract_has_math":false,"creators":["Milton-Barker, Jake Christopher"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Ingham, Eileen","Fisher, John","Stacy-Paul, Wilshaw"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09","date_published":"2015-09","updated_at":"2026-11-18T21:40:26Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.680542"],"render_values":[{"text":"uk.bl.ethos.680542","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/12037/1/Milton-Barker_JMB_MechanicalEngineering_PhD_2015.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A12037","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ingham, Eileen","Fisher, John","Stacy-Paul, Wilshaw"]},{"key":"dc:creator","label":"Author","values":["Milton-Barker, Jake Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09"]},{"key":"dc:date.issued","label":"Date","values":["2015-09"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/12037/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["ABBOTT, W. M., J. MEGERMAN, J. E. HASSON, G. L'ITALIEN and D. F. WARNOCK. 1987. Effect of compliance mismatch on vascular graft patency. Journal of Vascular Surgery, 5(2), pp.376-382. ANDROS, G., R. W. HARRIS, S. X. SALLES-CUNHA, L. B. DULAWA, R. W. OBLATH and R. L. APYAN. 1986. Arm veins for arterial revascularization of the leg: Arteriographic and clinical observations. Journal of Vascular Surgery, 4(5), pp.416-427. ANSI. 2011. ANSI/AAMI ST67 Sterilization of health care products Requirements and guidance for selecting a sterility assurance level (SAL) for products labeled 'sterile'. American National Standards Institute. ARIZONO, T., Y. IWAMOTO, K. OKUYAMA and Y. SUGIOKA. 1994. Ethylene oxide sterilization of bone grafts. Residual gas concentration and fibroblast toxicity. Acta Orthop Scand, 65(6), pp.640-2. BADYLAK, S. F., D. O. FREYTES and T. W. GILBERT. 2009. Extracellular matrix as a biological scaffold material: Structure and function. Acta Biomater, 5(1), pp.1-13. BALLESTRA, P. and J.-L. CUQ. 1998. Influence of Pressurized Carbon Dioxide on the Thermal Inactivation of Bacterial and Fungal Spores. LWT - Food Science and Technology, 31(1), pp.84-88. BALLYK, P. D., C. WALSH, J. BUTANY and M. OJHA. 1998. Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses. J Biomech, 31(3), pp.229-37. BARNES, C. P., S. A. SELL, E. D. BOLAND, D. G. SIMPSON and G. L. BOWLIN. 2007. Nanofiber technology: designing the next generation of tissue engineering scaffolds. Adv Drug Deliv Rev, 59(14), pp.1413-33. BASSIOUNY, H. S., S. WHITE, S. GLAGOV, E. CHOI, D. P. GIDDENS and C. K. ZARINS. 1992. Anastomotic intimal hyperplasia: Mechanical injury or flow induced. Journal of Vascular Surgery, 15(4), pp.708-717. BAULMANN, W. L. 1985. ELECTRON BEAM CURING OF UNSATURATED COATING MATERIALS. Patent number: BECHTOLD, J. E., D. T. EASTLUND, M. K. BUTTS, D. F. LAGERBORG and R. F. KYLE. 1994. The effects of freeze-drying and ethylene oxide sterilization on the mechanical properties of human patellar tendon. Am J Sports Med, 22(4), pp.562-6. BERGER, K., L. R. SAUVAGE, A. M. RAO and S. J. WOOD. 1972. Healing of arterial prostheses in man: its incompleteness. Ann Surg, 175(1), pp.118-27. BERGLUND, J. D., M. M. MOHSENI, R. M. NEREM and A. SAMBANIS. 2003. A biological hybrid model for collagen-based tissue engineered vascular constructs. Biomaterials, 24(7), pp.1241-1254. BOLLAND, F., S. KOROSSIS, S.-P. WILSHAW, E. INGHAM, J. FISHER, J. N. KEARNEY and J. SOUTHGATE. 2007. Development and characterisation of a full-thickness acellular porcine bladder matrix for tissue engineering. Biomaterials, 28(6), pp.1061-1070. BOOTH, C., S. A. KOROSSIS, H. E. WILCOX, K. G. WATTERSON, J. N. KEARNEY, J. FISHER and E. INGHAM. 2002. Tissue engineering of cardiac valve prostheses I: development and histological characterization of an acellular porcine scaffold. J Heart Valve Dis, 11(4), pp.457-62. BOU-GHARIOS, G., M. PONTICOS, V. RAJKUMAR and D. ABRAHAM. 2004. Extra-cellular matrix in vascular networks. Cell Proliferation, 37(3), pp.207-220. BOURASSA, M. G. 1994. Long-term vein graft patency. Current Opinion in Cardiology, 9(6), pp.685-691. BROCKBANK, K. M., W. R. MACLELLAN, J. XIE, S. HAMM-ALVAREZ, Z. CHEN and K. SCHENKE-LAYLAND. 2008. Quantitative second harmonic generation imaging of cartilage damage. Cell and Tissue Banking, 9(4), pp.299-307. BROTHERS, T. E., J. C. STANLEY, W. E. BURKEL and L. M. GRAHAM. 1990. Small-caliber polyurethane and polytetrafluoroethylene grafts: A comparative study in a canine aortoiliac model. J Biomed Mater Res, 24(6), pp.761-771. BRUCE ALBERTS, DENNIS BRAY, ALEXANDER JOHNSON, JULIAN LEWIS, MARTIN RAFF, KEITH ROBERTS and AND PETER WALTER. 2004. Essential Cell Biology. Garland Science CAMPBELL, D. G. and P. LI. 1999. Sterilization of HIV with irradiation: relevance to infected bone allografts. Aust N Z J Surg, 69(7), pp.517-21. CARLSON, B. E., J. C. ARCIERO and T. W. SECOMB. 2008. Theoretical model of blood flow autoregulation: roles of myogenic, shear-dependent, and metabolic responses. American Journal of Physiology - Heart and Circulatory Physiology, 295(4), pp.H1572-H1579. CHAKRABARTY, K. H., R. A. DAWSON, P. HARRIS, C. LAYTON, M. BABU, L. GOULD, J. PHILLIPS, I. LEIGH, C. GREEN, E. FREEDLANDER and S. MAC NEIL. 1999. Development of autologous human dermal-epidermal composites based on sterilized human allodermis for clinical use. Br J Dermatol, 141(5), pp.811-23. CHEUNG, D. T., N. PERELMAN, D. TONG and M. E. NIMNI. 1990. The effect of gamma-irradiation on collagen molecules, isolated alpha-chains, and crosslinked native fibers. J Biomed Mater Res, 24(5), pp.581-9. CHLUPÁC, J., E. FILOVÁ and L. BACÁKOVÁ. 2009. Blood vessel replacement: 50 years of development and tissue engineering paradigms in vascular surgery. Physiological research / Academia Scientiarum Bohemoslovaca, 58 Suppl 2, pp.S119-S139. COLLINS, R. G., R. VELJI, N. V. GUEVARA, M. J. HICKS, L. CHAN and A. L. BEAUDET. 2000. P-Selectin or Intercellular Adhesion Molecule (Icam)-1 Deficiency Substantially Protects against Atherosclerosis in Apolipoprotein E–Deficient Mice. The Journal of Experimental Medicine, 191(1), pp.189-194. COOPER, G. M. 2000. The Cell: A Molecular Approach. Sunderland (MA): Sinauer Associates. COURTMAN, D. W., C. A. PEREIRA, V. KASHEF, D. MCCOMB, J. M. LEE and G. J. WILSON. 1994. Development of a pericardial acellular matrix biomaterial: biochemical and mechanical effects of cell extraction. J Biomed Mater Res, 28(6), pp.655-66. CRAPO, P. M., T. W. GILBERT and S. F. BADYLAK. 2011. An overview of tissue and whole organ decellularization processes. Biomaterials, 32(12), pp.3233-3243. CYRUS, T., J. L. WITZTUM, D. J. RADER, R. TANGIRALA, S. FAZIO, M. F. LINTON and C. D. FUNK. 1999. Disruption of the 12/15-lipoxygenase gene diminishes atherosclerosis in apo E–deficient mice. The Journal of Clinical Investigation, 103(11), pp.1597-1604. DARDIK, H., N. MILLER, A. DARDIK, I. IBRAHIM, B. SUSSMAN, S. M. BERRY, F. WOLODIGER, M. KAHN and I. DARDIK. 1988. A decade of experience with the glutaraldehyde-tanned human umbilical cord vein graft for revascularization of the lower limb. J Vasc Surg, 7(2), pp.336-46. DARDIK, H., K. WENGERTER, F. QIN, A. PANGILINAN, F. SILVESTRI, F. WOLODIGER, M. KAHN, B. SUSSMAN and I. M. IBRAHIM. 2002. Comparative decades of experience with glutaraldehyde-tanned human umbilical cord vein graft for lower limb revascularization: an analysis of 1275 cases. J Vasc Surg, 35(1), pp.64-71. DAS, N., M. J. BRATBY, V. SHRIVASTAVA, A. J. CORNALL, C. R. DARBY, P. BOARDMAN, S. ANTHONY and R. UBEROI. 2011. Results of a seven-year, single-centre experience of the long-term outcomes of bovine ureter grafts used as novel conduits for haemodialysis fistulas. Cardiovasc Intervent Radiol, 34(5), pp.958-63. DAVIS, E. C. 1993. Endothelial cell connecting filaments anchor endothelial cells to the subjacent elastic lamina in the developing aortic intima of the mouse. Cell and Tissue Research, 272(2), pp.211-219. DEBELLE, L. and A. M. TAMBURRO. 1999. Elastin: molecular description and function. The International Journal of Biochemistry & Cell Biology, 31(2), pp.261-272. DERHAM, C., H. YOW, J. INGRAM, J. FISHER, E. INGHAM, S. A. KORROSIS and S. HOMER-VANNIASINKAM. 2008. Tissue engineering small-diameter vascular grafts: preparation of a biocompatible porcine ureteric scaffold. Tissue Eng Part A, 14(11), pp.1871-82. DESAI, M., A. M. SEIFALIAN and G. HAMILTON. 2011. Role of prosthetic conduits in coronary artery bypass grafting. European Journal of Cardio-thoracic Surgery, 40(2), pp.394-398. DEVIREDDY, R. V., M. R. NEIDERT, J. C. BISCHOF and R. T. TRANQUILLO. 2003. Cryopreservation of collagen-based tissue equivalents. I. Effect of freezing in the absence of cryoprotective agents. Tissue Eng, 9(6), pp.1089-100. DEWEESE, J. A., H. B. BARNER, E. B. MAHONEY and C. G. ROB. 1966. Autogenous venous bypass grafts and thromboendarterectomies for atherosclerotic lesions of the femoropopliteal arteries. Ann Surg, 163(2), pp.205-14. DINGEMANS, K. P., P. TEELING, J. H. LAGENDIJK and A. E. BECKER. 2000. Extracellular matrix of the human aortic media: An ultrastructural histochemical and immunohistochemical study of the adult aortic media. The Anatomical Record, 258(1), pp.1-14. DONG, Z. M., S. M. CHAPMAN, A. A. BROWN, P. S. FRENETTE, R. O. HYNES and D. D. WAGNER. 1998. The combined role of P- and E-selectins in atherosclerosis. The Journal of Clinical Investigation, 102(1), pp.145-152. EMA. 1996. Note for Guidance on Virus Validation Studies: The Design, Contribution and Interpretation of Studies Validating the Inactivation and Removal of Viruses. European Medicines Agency: Committee for Human Medicinal Products (CHMP) and the Biotechnology Working Party (BWP). EUROPE, C. 2004. European Pharmacopoeia 5.0: Vol-2. Council of Europe. EYRE, D. R., M. A. PAZ and P. M. GALLOP. 1984. Cross-linking in collagen and elastin. Annu Rev Biochem, 53, pp.717-48. F.D.A. 2007. Guidance for Industry and FDA Staff - Biological Indicator. Center for Devices and Radiological Health FEBBRAIO, M., E. A. PODREZ, J. D. SMITH, D. P. HAJJAR, S. L. HAZEN, H. F. HOFF, K. SHARMA and R. L. SILVERSTEIN. 2000. Targeted disruption of the class B scavenger receptor CD36 protects against atherosclerotic lesion development in mice. The Journal of Clinical Investigation, 105(8), pp.1049-1056. FIDELER, B. M., C. T. VANGSNESS, JR., T. MOORE, Z. LI and S. RASHEED. 1994. Effects of gamma irradiation on the human immunodeficiency virus. A study in frozen human bone-patellar ligament-bone grafts obtained from infected cadavera. J Bone Joint Surg Am, 76(7), pp.1032-5. FINEGOLD, J. A., P. ASARIA and D. P. FRANCIS. 2013. Mortality from ischaemic heart disease by country, region, and age: Statistics from World Health Organisation and United Nations. International Journal of Cardiology, 168(2), pp.934-945. FISHER, J., C. BOOTH and E. INGHAM. 2001. Decellularisation of matrices. Google Patents. FREYTES, D. O., R. M. STONER and S. F. BADYLAK. 2008. Uniaxial and biaxial properties of terminally sterilized porcine urinary bladder matrix scaffolds. J Biomed Mater Res B Appl Biomater, 84(2), pp.408-14. FUNG, Y. C. 1993. Biomechanics: mechanical properties of living tissues. 2nd ed. FUSSENEGGER, M., J. MEINHART, W. HOBLING, W. KULLICH, S. FUNK and G. BERNATZKY. 2003. Stabilized autologous fibrin-chondrocyte constructs for cartilage repair in vivo. Ann Plast Surg, 51(5), pp.493-8. GAGE, A. A. and J. BAUST. 1998. Mechanisms of tissue injury in cryosurgery. Cryobiology, 37(3), pp.171-86. GALILI, U. and K. SWANSON. 1991. Gene sequences suggest inactivation of alpha-1,3-galactosyltransferase in catarrhines after the divergence of apes from monkeys. Proc Natl Acad Sci U S A, 88(16), pp.7401-4. GEHRING, J. 1995. The influence of ionising radiation (Beta/gamma) on various polymers based on the result of the cytotoxicity test. Radiation Physics and Chemistry, 46(4–6, Part 1), pp.617-622. GERBI, B. J., J. A. ANTOLAK, F. C. DEIBEL, D. S. FOLLOWILL, M. G. HERMAN, P. D. HIGGINS, M. S. HUQ, D. N. MIHAILIDIS, E. D. YORKE, K. R. HOGSTROM and F. M. KHAN. 2009. Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25. Med Phys, 36(7), pp.3239-79. GILBERT, T. W., T. L. SELLARO and S. F. BADYLAK. 2006. Decellularization of tissues and organs. Biomaterials, 27(19), pp.3675-3683. GOISSIS, G., S. SUZIGAN, D. R. PARREIRA, J. V. MANIGLIA, D. M. BRAILE and S. RAYMUNDO. 2000. Preparation and Characterization of Collagen-Elastin Matrices From Blood Vessels Intended as Small Diameter Vascular Grafts. Artificial Organs, 24(3), pp.217-223. GOLDMAN, S., K. ZADINA, T. MORITZ, T. OVITT, G. SETHI, J. G. COPELAND, L. THOTTAPURATHU, B. KRASNICKA, N. ELLIS, R. J. ANDERSON, W. HENDERSON and V. A. C. S. GROUP. 2004. Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery: results from a Department of Veterans Affairs Cooperative Study. J Am Coll Cardiol, 44(11), pp.2149-56. GORHAM, S. D., S. SRIVASTAVA, D. A. FRENCH and R. SCOTT. 1993. The effect of gamma-ray and ethylene oxide sterilization on collagen-based wound-repair materials. Journal of Materials Science: Materials in Medicine, 4(1), pp.40-49. GOUK, S. S., T. M. LIM, S. H. TEOH and W. Q. SUN. 2008. Alterations of human acellular tissue matrix by gamma irradiation: histology, biomechanical property, stability, in vitro cell repopulation, and remodeling. J Biomed Mater Res B Appl Biomater, 84(1), pp.205-17. GRAINGER, D. J., P. R. KEMP, A. C. LIU, R. M. LAWN and J. C. METCALFE. 1994. Activation of transforming growth factor-[beta] is inhibited in transgenic apolipoprotein(a) mice. Nature, 370(6489), pp.460-462. GRASSL, E. D., T. R. OEGEMA and R. T. TRANQUILLO. 2002. Fibrin as an alternative biopolymer to type-I collagen for the fabrication of a media equivalent. J Biomed Mater Res, 60(4), pp.607-12. GRAY, H., C. M. GOSS and D. M. ALVARADO. 1973. Anatomy of the human body. Lea & Febiger Philadelphia. GREENWALD, S. E. and C. L. BERRY. 2000. Improving vascular grafts: the importance of mechanical and haemodynamic properties. The Journal of Pathology, 190(3), pp.292-299. GREISLER, H. P., E. D. ENDEAN, J. J. KLOSAK, J. ELLINGER, J. W. DENNIS, K. BUTTLE and D. U. KIM. 1988. Polyglactin 910/polydioxanone bicomponent totally resorbable vascular prostheses. Journal of vascular surgery : official publication, the Society for Vascular Surgery [and] International Society for Cardiovascular Surgery, North American Chapter, 7(5), pp.697-705. GREISLER, H. P., C. W. TATTERSALL, J. J. KLOSAK, E. A. CABUSAO, J. D. GARFIELD and D. U. KIM. 1991. Partially bioresorbable vascular grafts in dogs. Surgery, 110(4), pp.645-54; discussion 654-5. GRIEB, T. A., R. Y. FORNG, S. BOGDANSKY, C. RONHOLDT, B. PARKS, W. N. DROHAN, W. H. BURGESS and J. LIN. 2006. High-dose gamma irradiation for soft tissue allografts: High margin of safety with biomechanical integrity. J Orthop Res, 24(5), pp.1011-8. GRIMES, M., J. T. PEMBROKE and T. MCGLOUGHLIN. 2005. The effect of choice of sterilisation method on the biocompatibility and biodegradability of SIS (small intestinal submucosa). Biomed Mater Eng, 15(1-2), pp.65-71. GUILLIATT RS, DAVIES RPW, WILSHAW SP, AGGELI A. and INGHAM E. 2011. Peptide β-sheet self-assembly for the modification of acellular vascular grafts. European Cells and Materials,, 22, p57. H.S.C.I.C. 2011. Hospital episode statistics: Total procedures and interventions. HAMILTON, G., J. MEGERMAN, G. J. L'ITALIEN, D. F. WARNOCK, T. SCHMITZ-RIXEN, D. C. BREWSTER and W. M. ABBOTT. 1988. Prediction of aneurysm formation in vascular grafts of biologic origin. J Vasc Surg, 7(3), pp.400-8. HEGYI, L., J. N. SKEPPER, N. R. B. CARY and M. J. MITCHINSON. 1996. Foam cell apoptosis and the development of the lipid core of human atherosclerosis. The Journal of Pathology, 180(4), pp.423-429. HERTZER, N. R., E. G. BEVEN, J. R. YOUNG, P. J. O'HARA, W. F. RUSCHHAUPT, 3RD, R. A. GRAOR, V. G. DEWOLFE and L. C. MALJOVEC. 1984. Coronary artery disease in peripheral vascular patients. A classification of 1000 coronary angiograms and results of surgical management. Ann Surg, 199(2), pp.223-33. HIEMSTRA, H., M. TERSMETTE, A. H. VOS, J. OVER, M. P. VAN BERKEL and H. DE BREE. 1991. Inactivation of human immunodeficiency virus by gamma radiation and its effect on plasma and coagulation factors. Transfusion, 31(1), pp.32-9. HMS.HARVARD.EDU. 2011. Diseased Aorta. Television advertisement, hms.harvard.edu. Screened HOBURG, A., S. KESHLAF, T. SCHMIDT, M. SMITH, U. GOHS, C. PERKA, A. PRUSS and S. SCHEFFLER. 2011. Fractionation of high-dose electron beam irradiation of BPTB grafts provides significantly improved viscoelastic and structural properties compared to standard gamma irradiation. Knee Surg Sports Traumatol Arthrosc, 19(11), pp.1955-61. HOBURG, A., S. KESHLAF, T. SCHMIDT, M. SMITH, U. GOHS, C. PERKA, A. PRUSS and S. SCHEFFLER. 2015. High-dose electron beam sterilization of soft-tissue grafts maintains significantly improved biomechanical properties compared to standard gamma treatment. Cell and Tissue Banking, 16(2), pp.219-226. HOBURG, A. T., S. KESHLAF, T. SCHMIDT, M. SMITH, U. GOHS, C. PERKA, A. PRUSS and S. SCHEFFLER. 2010. Effect of electron beam irradiation on biomechanical properties of patellar tendon allografts in anterior cruciate ligament reconstruction. Am J Sports Med, 38(6), pp.1134-40. HODDE, J. and M. HILES. 2002. Virus safety of a porcine-derived medical device: evaluation of a viral inactivation method. Biotechnol Bioeng, 79(2), pp.211-6. HOENIG, M. R., G. R. CAMPBELL, B. E. ROLFE and J. H. CAMPBELL. 2005. Tissue-Engineered Blood Vessels: Alternative to Autologous Grafts? Arterioscler Thromb Vasc Biol, 25(6), pp.1128-1134. HOGSTROM, K. R. and P. R. ALMOND. 2006. Review of electron beam therapy physics. Phys Med Biol, 51(13), pp.R455-89. HOLMES, R. V. 2013. Assessing microbial proliferation and its prevention in the preparation of decellularised human dermis grafts. Submitted in accordance with the requirements for the degree of MSc by Research thesis, The University of Leeds HU, Y., Z. ZHANG, E. TORSNEY, A. R. AFZAL, F. DAVISON, B. METZLER and Q. XU. 2004. Abundant progenitor cells in the adventitia contribute to atherosclerosis of vein grafts in ApoE-deficient mice. The Journal of Clinical Investigation, 113(9), pp.1258-1265. HUMPHREY, J. D. and C. A. TAYLOR. 2008. Intracranial and Abdominal Aortic Aneurysms: Similarities, Differences, and Need for a New Class of Computational Models. Annual Review of Biomedical Engineering, 10(1), pp.221-246. HUYNH, T., G. ABRAHAM, J. MURRAY, K. BROCKBANK, P. O. HAGEN and S. SULLIVAN. 1999. Remodeling of an acellular collagen graft into a physiologically responsive neovessel. Nat Biotechnol, 17(11), pp.1083-6. ICH. 1997. Q5A(R1) Viral Safety Evaluation of Biotechnology Products Derived From Cell Lines of Human or Animal Origin. International Conference on Harmonisation. IJIRI, S., T. YAMAMURO, T. NAKAMURA, S. KOTANI and K. NOTOYA. 1994. Effect of sterilization on bone morphogenetic protein. J Orthop Res, 12(5), pp.628-36. INGHAM, E., J. FISHER and S. P. WILSHAW. 2010. Acellular vascular products. Patent number: WO/2012/042250. INTERNATIONAL STANDARD ISO/DIS 7198. 1998. Cardiovascular implants -- Tubular vascular prostheses. ISHIKAWA, H., M. SHIMODA, K. TAMAYA, A. YONEKURA, T. KAWANO and Y. OSAJIMA. 1997. Inactivation of Bacillus spores by the supercritical carbon dioxide micro-bubble method. Biosci Biotechnol Biochem, 61(6), pp.1022-3. ISO. 11135:2014 Sterilization of health-care products -- Ethylene oxide -- Requirements for the development, validation and routine control of a sterilization process for medical devices. ISO. 11137-2:2012. Sterilization of health care products — Radiation. Part 2: Establishing the sterilization dose. ISO. 22442-3:2007. Medical devices utilizing animal tissues and their derivatives. Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents. International Organization for Standardization. ISO. 10993-7:2008 ISO. Biological evaluation of medical devices. Ethylene oxide sterilization residuals. International Organization for Standardization. JACKSON, D. W., G. E. WINDLER and T. M. SIMON. 1990. Intraarticular reaction associated with the use of freeze-dried, ethylene oxide-sterilized bone-patella tendon-bone allografts in the reconstruction of the anterior cruciate ligament. Am J Sports Med, 18(1), pp.1-10; discussion 10-1. JAN, K.-M. 2010. Physiology : Hemodynamics [online]. [Accessed 2011]. Available from: http://www.columbia.edu/~kj3/Chapter2.htm. JESCHKE, M. G., V. HERMANUTZ, S. E. WOLF and G. B. KOVEKER. 1999. Polyurethane vascular prostheses decreases neointimal formation compared with expanded polytetrafluoroethylene. J Vasc Surg, 29(1), pp.168-76. JIANG, B., Z. WU, H. ZHAO, F. TANG, J. LU, Q. WEI and X. ZHANG. 2006. Electron beam irradiation modification of collagen membrane. Biomaterials, 27(1), pp.15-23. JOHNSON, C. P., T. HOW, M. SCRAGGS, C. R. WEST and J. BURNS. 2000. A biomechanical study of the human vertebral artery with implications for fatal arterial injury. Forensic Sci Int, 109(3), pp.169-82. JOHNSON, L. R. and J. H. BYRNE. 1998. Essential medical physiology. Lippincott-Raven. JORDY, A., R. HOFF-JORGENSEN, A. FLAGSTAD and E. LUND. 1975. Virus inactivation by ethylene oxide containing gases. Acta Vet Scand, 16(3), pp.379-87. KAKIUCHI, M., K. ONO, A. NISHIMURA and H. SHIOKAWA. 1996. Preparation of bank bone using defatting, freeze-drying and sterilisation with ethylene oxide gas. International Orthopaedics, 20(3), pp.142-146. KAKU, N., H. TSUMURA, M. KATAOKA, H. TAIRA and T. TORISU. 2002. Influence of aeration, storage, and rinsing conditions on residual ethylene oxide in freeze-dried bone allograft. J Orthop Sci, 7(2), pp.238-42. KAMIHIRA, M., M. TANIGUCHI and T. KOBAYASHI. 1987. Sterilization of Microorganisms with Supercritical Carbon Dioxide(Food & Nutrition). Agricultural and biological chemistry, 51(2), pp.407-412. KANNAN, R. Y., H. J. SALACINSKI, P. E. BUTLER, G. HAMILTON and A. M. SEIFALIAN. 2005. Current status of prosthetic bypass grafts: a review. J Biomed Mater Res B Appl Biomater, 74(1), pp.570-81. KAULITZKI, S. 2011. Cardiovascular System. Television advertisement, www.dreamstime.com. Screened KEARNEY, J. N., R. BOJAR and K. T. HOLLAND. 1993. Ethylene oxide sterilisation of allogenic bone implants. Clin Mater, 12(3), pp.129-35. KEARNEY, J. N., U. C. FRANKLIN, V. AGUIRREGOICOA and K. T. HOLLAND. 1989. Evaluation of ethylene oxide sterilization of tissue implants. J Hosp Infect, 13(1), pp.71-80. KENNEALEY, P. T., N. ELIAS, M. HERTL, D. S. KO, R. F. SAIDI, J. F. MARKMANN, E. E. SMOOT, D. A. SCHOENFELD and T. KAWAI. 2011. A prospective, randomized comparison of bovine carotid artery and expanded polytetrafluoroethylene for permanent hemodialysis vascular access. J Vasc Surg, 53(6), pp.1640-8. KER, R. F. 1981. Dynamic tensile properties of the plantaris tendon of sheep (Ovis aries). J Exp Biol, 93, pp.283-302. KHAIRA, H. S. and H. VOHRA. 2002. True aneurysm in a femoro-popliteal dacron graft - A case report and literature review. Cardiovascular Surgery, 10(6), pp.644-646. KLABUNDE, R. E. 2005. Cardiovascular Physiology Concepts. Lippincott Williams & Wilkins. KLINKERT, P., P. N. POST, P. J. BRESLAU and J. H. VAN BOCKEL. 2004. Saphenous vein versus PTFE for above-knee femoropopliteal bypass. A review of the literature. Eur J Vasc Endovasc Surg, 27(4), pp.357-62. KLOSE, B. Z. E., D-34431 MARSBERG, DE), GOHS, UWE (WEINBERGSTRASSE 68 F, D-01129 DRESDEN, DE), BARTEL, RAINER (STANGE STRASSE 2, 01324 DRESDEN, DE). 2007. A PROCESS FOR THE PREPARATION OF A PACKAGE COMPRISING A STERILISED BULK OF A DRUG SUBSTANCE, AND A PACKAGE COMPRISING A STERILISED BULK OF A PENICILLIN. Patent number: KNIGHT, R. L., C. BOOTH, H. E. WILCOX, J. FISHER and E. INGHAM. 2005. Tissue engineering of cardiac valves: re-seeding of acellular porcine aortic valve matrices with human mesenchymal progenitor cells. J Heart Valve Dis, 14(6), pp.806-13. KOCH, S., T. C. FLANAGAN, J. S. SACHWEH, F. TANIOS, H. SCHNOERING, T. DEICHMANN, V. ELLA, M. KELLOMAKI, N. GRONLOH, T. GRIES, R. TOLBA, T. SCHMITZ-RODE and S. JOCKENHOEVEL. 2010. Fibrin-polylactide-based tissue-engineered vascular graft in the arterial circulation. Biomaterials, 31(17), pp.4731-9. KONIG, G., T. N. MCALLISTER, N. DUSSERRE, S. A. GARRIDO, C. IYICAN, A. MARINI, A. FIORILLO, H. AVILA, W. WYSTRYCHOWSKI, K. ZAGALSKI, M. MARUSZEWSKI, A. L. JONES, L. CIERPKA, L. M. DE LA FUENTE and N. L'HEUREUX. 2009. Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery. Biomaterials, 30(8), pp.1542-1550. KOROSSIS, S. A., C. BOOTH, H. E. WILCOX, K. G. WATTERSON, J. N. KEARNEY, J. FISHER and E. INGHAM. 2002. Tissue engineering of cardiac valve prostheses II: biomechanical characterization of decellularized porcine aortic heart valves. J Heart Valve Dis, 11(4), pp.463-71. L'HEUREUX, N., N. DUSSERRE, A. MARINI, S. GARRIDO, L. DE LA FUENTE and T. MCALLISTER. 2007a. Technology insight: the evolution of tissue-engineered vascular grafts--from research to clinical practice. Nat Clin Pract Cardiovasc Med, 4(7), pp.389-95. L'HEUREUX, N., L. GERMAIN, R. LABBE and F. A. AUGER. 1993. In vitro construction of a human blood vessel from cultured vascular cells: a morphologic study. J Vasc Surg, 17(3), pp.499-509. L'HEUREUX, N., T. N. MCALLISTER and L. M. DE LA FUENTE. 2007b. Tissue-Engineered Blood Vessel for Adult Arterial Revascularization. New England Journal of Medicine, 357(14), pp.1451-1453. LAING, S. T. and D. D. MCPHERSON. 2009. Cardiovascular therapeutic uses of targeted ultrasound contrast agents. Cardiovasc Res, 83(4), pp.626-35. LANTZ, G. C., S. F. BADYLAK, A. C. COFFEY, L. A. GEDDES and W. E. BLEVINS. 1990. Small intestinal submucosa as a small-diameter arterial graft in the dog. J Invest Surg, 3(3), pp.217-27. LANTZ, G. C., S. F. BADYLAK, M. C. HILES, A. C. COFFEY, L. A. GEDDES, K. KOKINI, G. E. SANDUSKY and R. J. MORFF. 1993. Small intestinal submucosa as a vascular graft: a review. J Invest Surg, 6(3), pp.297-310. LEE, Y. and K. B. SONG. 2002. Effect of gamma-irradiation on the molecular properties of myoglobin. J Biochem Mol Biol, 35(6), pp.590-4. LEROUGE, S. and A. SIMMONS. 2012. Sterilisation of Biomaterials and Medical Devices. Elsevier Science. LI, A. C. A. C. and C. K. C. K. GLASS. 2002. The macrophage foam cell as a target for therapeutic intervention. Nature medicine, 8(11), pp.1235-1242. LIN, M.-G., T.-L. YANG, C.-T. CHIANG, H.-C. KAO, J.-N. LEE, W. LO, S.-H. JEE, Y.-F. CHEN, C.-Y. DONG and S.-J. LIN. 2006. Evaluation of dermal thermal damage by multiphoton autofluorescence and second-harmonic-generation microscopy. Journal of Biomedical Optics, 11(6), pp.064006-064006-6. LIU, M. and J. YANG. 2009. Electrokinetic effect of the endothelial glycocalyx layer on two-phase blood flow in small blood vessels. Microvascular Research, 78(1), pp.14-19. LOMAS, R. J., H. L. GILLAN, J. B. MATTHEWS, E. INGHAM and J. N. KEARNEY. 2001. An evaluation of the capacity of differently prepared demineralised bone matrices (DBM) and toxic residuals of ethylene oxide (EtOx) to provoke an inflammatory response in vitro. Biomaterials, 22(9), pp.913-21. LUCAS, A. D., K. MERRITT, V. M. HITCHINS, T. O. WOODS, S. G. MCNAMEE, D. B. LYLE and S. A. BROWN. 2003. Residual ethylene oxide in medical devices and device material. J Biomed Mater Res B Appl Biomater, 66(2), pp.548-52. LUSIS, A. J. 2000. Atherosclerosis. Nature, 407(6801), pp.233-241. MADDEN, R., G. LIPKOWITZ, B. BENEDETTO, A. KURBANOV, M. MILLER and L. BOW. 2002. Decellularized cadaver vein allografts used for hemodialysis access do not cause allosensitization or preclude kidney transplantation. Am J Kidney Dis, 40(6), pp.1240-3. MADDEN, R. L., G. S. LIPKOWITZ, B. J. BROWNE and A. KURBANOV. 2005. A comparison of cryopreserved vein allografts and prosthetic grafts for hemodialysis access. Ann Vasc Surg, 19(5), pp.686-91. MARANTO, A. R. and F. J. SCHOEN. 1988. Phosphatase enzyme activity is retained in glutaraldehyde treated bioprosthetic heart valves. ASAIO Trans, 34(3), pp.827-30. MARRECO, P. R., P. D. L. MOREIRA, S. C. GENARI and Â. M. MORAES. 2004. Effects of different sterilization methods on the morphology, mechanical properties, and cytotoxicity of chitosan membranes used as wound dressings. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 71B(2), pp.268-277. MARTIN, R. S., 3RD, W. H. EDWARDS, J. L. MULHERIN, JR., W. H. EDWARDS, JR., J. M. JENKINS and S. J. HOFF. 1994. Cryopreserved saphenous vein allografts for below-knee lower extremity revascularization. Ann Surg, 219(6), pp.664-70; discussion 670-2. MCALLISTER, T. N., M. MARUSZEWSKI, S. A. GARRIDO, W. WYSTRYCHOWSKI, N. DUSSERRE, A. MARINI, K. ZAGALSKI, A. FIORILLO, H. AVILA, X. MANGLANO, J. ANTONELLI, A. KOCHER, M. ZEMBALA, L. CIERPKA, L. M. DE LA FUENTE and N. L'HEUREUX. 2009. Effectiveness of haemodialysis access with an autologous tissue-engineered vascular graft: a multicentre cohort study. The Lancet, 373(9673), pp.1440-1446. MCDONNELL, G. E. 2007. Antisepsis, Disinfection, and Sterilization: Types, Action, and Resistance. ASM Press. MCPHERSON, T. B., H. LIANG, R. D. RECORD and S. F. BADYLAK. 2000. Galalpha(1,3)Gal epitope in porcine small intestinal submucosa. Tissue Eng, 6(3), pp.233-9. MERYMAN, H. T. 1960. General principles of freezing and freezing injury in cellular materials. Ann N Y Acad Sci, 85, pp.503-9. MESTAS, J. and K. LEY. 2008. Monocyte-Endothelial Cell Interactions in the Development of Atherosclerosis. Trends in Cardiovascular Medicine, 18(6), pp.228-232. MEYERS, M. A., P.-Y. CHEN, A. Y.-M. LIN and Y. SEKI. 2008. Biological materials: Structure and mechanical properties. Progress in Materials Science, 53(1), pp.1-206. MILLS, N. L. and C. T. EVERSON. 1989. Rigt gastroepiploic artery: A third arterial conduit for coronary artery bypass. The Annals of Thoracic Surgery, 47(5), pp.706-711. MIRSADRAEE, S., H. E. WILCOX, S. A. KOROSSIS, J. N. KEARNEY, K. G. WATTERSON, J. FISHER and E. INGHAM. 2006. Development and characterization of an acellular human pericardial matrix for tissue engineering. Tissue Eng, 12(4), pp.763-73. MITRA, A. K., D. M. GANGAHAR and D. K. AGRAWAL. 2006. Cellular, molecular and immunological mechanisms in the pathophysiology of vein graft intimal hyperplasia. Immunol Cell Biol, 84(2), pp.115-24. MOORE, T. M., E. GENDLER and E. GENDLER. 2004. Viruses adsorbed on musculoskeletal allografts are inactivated by terminal ethylene oxide disinfection. J Orthop Res, 22(6), pp.1358-61. MORINAGA, K., K. OKADOME, M. KUROKI, T. MIYAZAKI, Y. MUTO and K. INOKUCHI. 1985. Effect of wall shear stress on intimal thickening of arterially transplanted autogenous veins in dogs. Journal of Vascular Surgery, 2(3), pp.430-433. NAKAGAWA, Y., K. OTA, Y. SATO, S. TERAOKA and T. AGISHI. 1995. Clinical trial of new polyurethane vascular grafts for hemodialysis: compared with expanded polytetrafluoroethylene grafts. Artif Organs, 19(12), pp.1227-32. NATHER, A., N. YUSOF and N. HILMY. 2007. Radiation in Tissue Banking: Basic Science and Clinical Applications of Irradiated Tissue Allografts. World Scientific Publishing Company. NEVEN, E. and P. C. D'HAESE. 2011. Vascular Calcification in Chronic Renal Failure: What Have We Learned From Animal Studies? Circulation Research, 108(2), pp.249-264. NEWBY, A. C. and A. B. ZALTSMAN. 2000. Molecular mechanisms in intimal hyperplasia. The Journal of Pathology, 190(3), pp.300-309. NIKLASON, L. E., W. ABBOTT, J. GAO, B. KLAGGES, K. K. HIRSCHI, K. ULUBAYRAM, N. CONROY, R. JONES, A. VASANAWALA, S. SANZGIRI and R. LANGER. 2001. Morphologic and mechanical characteristics of engineered bovine arteries. J Vasc Surg, 33(3), pp.628-38. OKUHN, S. P., D. P. CONNELLY, N. CALAKOS, L. FERRELL, P. MAN-XIANG and J. GOLDSTONE. 1989. Does compliance mismatch alone cause neointimal hyperplasia? Journal of Vascular Surgery, 9(1), pp.35-45. OLDE DAMINK, L. H., P. J. DIJKSTRA, M. J. VAN LUYN, P. B. VAN WACHEM, P. NIEUWENHUIS and J. FEIJEN. 1995. Influence of ethylene oxide gas treatment on the in vitro degradation behavior of dermal sheep collagen. J Biomed Mater Res, 29(2), pp.149-55. OWEN, K., S. P. WILSHAW, S. HOMER-VANNIASINKAM, R. A. BOJAR, H. BERRY and E. INGHAM. 2012. Assessment of the antimicrobial activity of acellular vascular grafts. Eur J Vasc Endovasc Surg, 43(5), pp.573-81. PANKAJAKSHAN, D. and D. K. AGRAWAL. 2010. Scaffolds in tissue engineering of blood vessels. Canadian Journal of Physiology and Pharmacology, 88(9), pp.855-873. PARISI, A. and A. D. ANTOINE. 1974. Increased radiation resistance of vegetative Bacillus pumilus. Appl Microbiol, 28(1), pp.41-6. PARK, I. S., S.-H. KIM, Y. H. KIM, I. H. KIM and S. H. KIM. 2009. A Collagen/Smooth Muscle Cell-Incorporated Elastic Scaffold for Tissue-Engineered Vascular Grafts. Journal of Biomaterials Science, Polymer Edition, 20(11), pp.1645-1660. PARKER, W., S. SAADI, S. S. LIN, Z. E. HOLZKNECHT, M. BUSTOS and J. L. PLATT. 1996. Transplantation of discordant xenografts: a challenge revisited. Immunol Today, 17(8), pp.373-8. PHILLIPS, C. R. and S. KAYE. 1949. The sterilizing action of gaseous ethylene oxide; a review. Am J Hyg, 50(3), pp.270-9. PONTICELLI, C. 2012. The mechanisms of acute transplant rejection revisited. J Nephrol, 25(2), pp.150-8. PREVENTING-A-HEART-ATTACK.COM. 2011. Anatomy of the heart. Television advertisement. Screened PROLO, D. J., P. W. PEDROTTI and D. H. WHITE. 1980. Ethylene Oxide Sterilization of Bone, Dura Mater, and Fascia Lata for Human Transplantation. Neurosurgery, 6(5), pp.529-539. QIU, Q. Q., P. LEAMY, J. BRITTINGHAM, J. POMERLEAU, N. KABARIA and J. CONNOR. 2009. Inactivation of bacterial spores and viruses in biological material using supercritical carbon dioxide with sterilant. J Biomed Mater Res B Appl Biomater, 91(2), pp.572-8. RADER, D. J. and A. DAUGHERTY. 2008. Translating molecular discoveries into new therapies for atherosclerosis. Nature, 451(7181), pp.904-913. RANDON, C., B. JACOBS, F. DE RYCK, H. BEELE and F. VERMASSEN. 2010. Fifteen years of infrapopliteal arterial reconstructions with cryopreserved venous allografts for limb salvage. J Vasc Surg, 51(4), pp.869-77. ROLL, S., J. MULLER-NORDHORN, T. KEIL, H. SCHOLZ, D. EIDT, W. GREINER and S. N. WILLICH. 2008. Dacron vs. PTFE as bypass materials in peripheral vascular surgery--systematic review and meta-analysis. BMC Surg, 8, p22. ROTHSCHILD, M. F., A. RUVINSKY and C. A. B. INTERNATIONAL. 2011. The Genetics of the Pig. CABI. SAGOO, P., G. LOMBARDI and R. I. LECHLER. 2012. Relevance of Regulatory T cell Promotion of Donor-specific Tolerance in Solid Organ Transplantation. Frontiers in Immunology, 3. SAHA, P., B. MODARAI, J. HUMPHRIES, K. MATTOCK, M. WALTHAM, K. G. BURNAND and A. SMITH. 2009. The monocyte/macrophage as a therapeutic target in atherosclerosis. Current Opinion in Pharmacology, 9(2), pp.109-118. SALACINSKI, H. J., S. GOLDNER, A. GIUDICEANDREA, G. HAMILTON, A. M. SEIFALIAN, A. EDWARDS and R. J. CARSON. 2001. The Mechanical Behavior of Vascular Grafts: A Review. Journal of Biomaterials Applications, 15(3), pp.241-278. SARAZIN, P., X. ROY and B. D. FAVIS. 2004. Controlled preparation and properties of porous poly(-lactide) obtained from a co-continuous blend of two biodegradable polymers. Biomaterials, 25(28), pp.5965-5978. SARKAR, S., H. J. SALACINSKI, G. HAMILTON and A. M. SEIFALIAN. 2006. The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency. Eur J Vasc Endovasc Surg, 31(6), pp.627-36. SAUVAGE, L. R., K. E. BERGER, S. J. WOOD, S. G. YATES, II, J. C. SMITH and P. B. MANSFIELD. 1974. Interspecies healing of porous arterial prostheses: Observations, 1960 to 1974. Archives of Surgery, 109(5), pp.698-705. SCHANER, P. J., N. D. MARTIN, T. N. TULENKO, I. M. SHAPIRO, N. A. TAROLA, R. F. LEICHTER, R. A. CARABASI and P. J. DIMUZIO. 2004. Decellularized vein as a potential scaffold for vascular tissue engineering. Journal of Vascular Surgery, 40(1), pp.146-153. SCHENKE-LAYLAND, K. 2008. Non-invasive multiphoton imaging of extracellular matrix structures. Journal of Biophotonics, 1(6), pp.451-462. SCHERZER, T. and A. BECKERT. 1997. Electron beam curing of methacrylated gelatin studied by EPR and FT-Raman spectroscopy. Macromolecular Symposia, 119(1), pp.299-307. SCHMITZ-RIXEN, T., S. LEPIDI and G. HAMILTON. 1993. [Compliance: a fundamental biomechanical property in the maintenance of an arterial reconstruction?]. Ann Ital Chir, 64(1), pp.15-27. SCHOEN, F. J. 1987. Cardiac valve prostheses: pathological and bioengineering considerations. J Card Surg, 2(1), pp.65-108. SCHULZE-BAUER, C. A. J., P. REGITNIG and G. A. HOLZAPFEL. 2002. Mechanics of the human femoral adventitia including the high-pressure response. American Journal of Physiology - Heart and Circulatory Physiology, 282(6), pp.H2427-H2440. SCHWARTZ, H. E., M. J. MATAVA, F. S. PROCH, C. A. BUTLER, A. RATCLIFFE, M. LEVY and D. L. BUTLER. 2006. The Effect of Gamma Irradiation on Anterior Cruciate Ligament Allograft Biomechanical and Biochemical Properties in the Caprine Model at Time Zero and at 6 Months After Surgery. The American Journal of Sports Medicine, 34(11), pp.1747-1755. SEIFERT, K. B., D. ALBO, JR., H. KNOWLTON and D. J. LYMAN. 1979. Effect of elasticity of prosthetic wall on patency of small-diameter arterial prostheses. Surg Forum, 30, pp.206-8. SETO, A., C. J. GATT, JR. and M. G. DUNN. 2009. Improved tendon radioprotection by combined cross-linking and free radical scavenging. Clin Orthop Relat Res, 467(11), pp.2994-3001. SHANAHAN, C. M. 2013. Mechanisms of vascular calcification in CKD[mdash]evidence for premature ageing? Nat Rev Nephrol, 9(11), pp.661-670. SHEKHONIN, B. V., S. P. DOMOGATSKY, V. R. MUZYKANTOV, G. L. IDELSON and V. S. RUKOSUEV. 1985. Distribution of Type I, III, IV and V Collagen in Normal and Atherosclerotic Human Arterial Wall: Immunomorphological Characteristics. Collagen and Related Research, 5(4), pp.355-368. SIMON, P., M. T. KASIMIR, G. SEEBACHER, G. WEIGEL, R. ULLRICH, U. SALZER-MUHAR, E. RIEDER and E. WOLNER. 2003. Early failure of the tissue engineered porcine heart valve SYNERGRAFT™ in pediatric patients. European Journal of Cardio-thoracic Surgery, 23(6), pp.1002-1006. SMITH, C. W., I. S. YOUNG and J. N. KEARNEY. 1996. Mechanical properties of tendons: changes with sterilization and preservation. J Biomech Eng, 118(1), pp.56-61. SMITH, J. D., E. TROGAN, M. GINSBERG, C. GRIGAUX, J. TIAN and M. MIYATA. 1995. Decreased atherosclerosis in mice deficient in both macrophage colony-stimulating factor (op) and apolipoprotein E. Proceedings of the National Academy of Sciences, 92(18), pp.8264-8268. SOKAL, R. R. and F. J. ROHLF. 1981. Biometry: The Principles and Practice of Statistics in Biological Research. W. H. Freeman. SOLDANI, G., P. LOSI, M. BERNABEI, S. BURCHIELLI, D. CHIAPPINO, S. KULL, E. BRIGANTI and D. SPILLER. 2010. Long term performance of small-diameter vascular grafts made of a poly(ether)urethane-polydimethylsiloxane semi-interpenetrating polymeric network. Biomaterials, 31(9), pp.2592-605. SOTTIURAI, V. S., J. S. YAO, R. C. BATSON, S. L. SUE, R. JONES and Y. A. NAKAMURA. 1989. Distal anastomotic intimal hyperplasia: histopathologic character and biogenesis. Ann Vasc Surg, 3(1), pp.26-33. SPARK, J. I., S. YELURI, C. DERHAM, Y. T. WONG and D. LEITCH. 2008. Incomplete cellular depopulation may explain the high failure rate of bovine ureteric grafts. Br J Surg, 95(5), pp.582-5. SPILIMBERGO, S. and A. BERTUCCO. 2003. Non-thermal bacterial inactivation with dense CO(2). Biotechnol Bioeng, 84(6), pp.627-38. SPIRE, B., D. DORMONT, F. BARRE-SINOUSSI, L. MONTAGNIER and J. C. CHERMANN. 1985. Inactivation of lymphadenopathy-associated virus by heat, gamma rays, and ultraviolet light. Lancet, 1(8422), pp.188-9. STENMARK, K. R., E. NOZIK-GRAYCK, E. GERASIMOVSKAYA, A. ANWAR, M. LI, S. RIDDLE and M. FRID. 2006. The Adventitia: Essential Role in Pulmonary Vascular Remodeling. Comprehensive Physiology. John Wiley & Sons, Inc. SULLIVAN, R., A. C. FASSOLITIS, E. P. LARKIN, R. B. READ, JR. and J. T. PEELER. 1971. Inactivation of thirty viruses by gamma radiation. Appl Microbiol, 22(1), pp.61-5. SUMPIO, B. E., J. TIMOTHY RILEY and A. DARDIK. 2002. Cells in focus: endothelial cell. The International Journal of Biochemistry & Cell Biology, 34(12), pp.1508-1512. SUN, W. Q. and P. LEUNG. 2008. Calorimetric study of extracellular tissue matrix degradation and instability after gamma irradiation. Acta Biomater, 4(4), pp.817-26. SUZUKI, H. H., Y. Y. KURIHARA, M. M. TAKEYA, N. N. KAMADA, M. M. KATAOKA, K. K. JISHAGE, O. O. UEDA, H. H. SAKAGUCHI, T. T. HIGASHI, T. T. SUZUKI, Y. Y. TAKASHIMA, Y. Y. KAWABE, O. O. CYNSHI, Y. Y. WADA, M. M. HONDA, H. H. KURIHARA, H. H. ABURATANI, T. T. DOI, A. A. MATSUMOTO, S. S. AZUMA, T. T. NODA, Y. Y. TOYODA, H. H. ITAKURA, Y. Y. YAZAKI and T. T. KODAMA. 1997. A role for macrophage scavenger receptors in atherosclerosis and susceptibility to infection. Nature, 386(6622), pp.292-296. SWARTZ, D. D., J. A. RUSSELL and S. T. ANDREADIS. 2005. Engineering of fibrin-based functional and implantable small-diameter blood vessels. Am J Physiol Heart Circ Physiol, 288(3), pp.H1451-60. TATTERTON, M., S. P. WILSHAW, E. INGHAM and S. HOMER-VANNIASINKAM. 2012. The use of antithrombotic therapies in reducing synthetic small-diameter vascular graft thrombosis. Vasc Endovascular Surg, 46(3), pp.212-22. TEEBKEN, O. E. and A. HAVERICH. 2002. Tissue Engineering of Small Diameter Vascular Grafts. European Journal of Vascular and Endovascular Surgery, 23(6), pp.475-485. THEODOSSIOU, T. A., C. THRASIVOULOU, C. EKWOBI and D. L. BECKER. 2006. Second Harmonic Generation Confocal Microscopy of Collagen Type I from Rat Tendon Cryosections. Biophysical Journal, 91(12), pp.4665-4677. TILANUS, H. W., H. OBERTOP and H. VAN URK. 1985. Saphenous vein or PTFE for femoropopliteal bypass. A prospective randomized trial. Ann Surg, 202(6), pp.780-2. TILLMAN, B. W., S. K. YAZDANI, S. J. LEE, R. L. GEARY, A. ATALA and J. J. YOO. 2009. The in vivo stability of electrospun polycaprolactone-collagen scaffolds in vascular reconstruction. Biomaterials, 30(4), pp.583-8. TIMPL, R. 1996. Macromolecular organization of basement membranes. Current Opinion in Cell Biology, 8(5), pp.618-624. TIWARI, A., K. S. CHENG, H. SALACINSKI, G. HAMILTON and A. M. SEIFALIAN. 2003. Improving the Patency of Vascular Bypass Grafts: the Role of Suture Materials and Surgical Techniques on Reducing Anastomotic Compliance Mismatch. European Journal of Vascular and Endovascular Surgery, 25(4), pp.287-295. TIWARI, A., H. SALACINSKI, A. M. SEIFALIAN and G. HAMILTON. 2002. New prostheses for use in bypass grafts with special emphasis on polyurethanes. Cardiovascular Surgery, 10(3), pp.191-197. TRANQUILLO, R. T., T. S. GIRTON, B. A. BROMBEREK, T. G. TRIEBES and D. L. MOORADIAN. 1996. Magnetically orientated tissue-equivalent tubes: application to a circumferentially orientated media-equivalent. Biomaterials, 17(3), pp.349-57. TRUBEL, W., A. MORITZ, H. SCHIMA, F. RADERER, R. SCHERER, R. ULLRICH, U. LOSERT and P. POLTERAUER. 1994. Compliance and formation of distal anastomotic intimal hyperplasia in Dacron mesh tube constricted veins used as arterial bypass grafts. ASAIO Journal, 40(3), pp.M273-M278. TSCHOEKE, B., T. C. FLANAGAN, S. KOCH, M. S. HARWOKO, T. DEICHMANN, V. ELLA, J. S. SACHWEH, M. KELLOMAKI, T. GRIES, T. SCHMITZ-RODE and S. JOCKENHOEVEL. 2009. Tissue-engineered small-caliber vascular graft based on a novel biodegradable composite fibrin-polylactide scaffold. Tissue Eng Part A, 15(8), pp.1909-18. VALENTE, M., U. BORTOLOTTI and G. THIENE. 1985. Ultrastructural substrates of dystrophic calcification in porcine bioprosthetic valve failure. Am J Pathol, 119(1), pp.12-21. VAN DAMME, H., M. DEPREZ, E. CREEMERS and R. LIMET. 2005. Intrinsic structural failure of polyester (Dacron) vascular grafts. A general review. Acta Chirurgica Belgica, 105(3), pp.249-255. VAN DET, R. J., B. H. VRIENS, J. VAN DER PALEN and R. H. GEELKERKEN. 2009. Dacron or ePTFE for femoro-popliteal above-knee bypass grafting: short- and long-term results of a multicentre randomised trial. Eur J Vasc Endovasc Surg, 37(4), pp.457-63. VANGSNESS, C. T., JR., I. A. GARCIA, C. R. MILLS, M. A. KAINER, M. R. ROBERTS and T. M. MOORE. 2003. Allograft transplantation in the knee: tissue regulation, procurement, processing, and sterilization. Am J Sports Med, 31(3), pp.474-81. VEITH, F. J., C. M. MOSS, S. SPRAYREGEN and C. MONTEFUSCO. 1979. Preoperative saphenous venography in arterial reconstructive surgery of the lower extremity. Surgery, 85(3), pp.253-6. VESELY, I., R. NOSEWORTHY and G. PRINGLE. 1995. The hybrid xenograft/autograft bioprosthetic heart valve: In vivo evaluation of tissue extraction. The Annals of Thoracic Surgery, 60, Supplement 2(0), pp.S359-S364. W.H.O. 2011. World Health Organisation: Global Health Observatory - Number of deaths : World by cause (2000-2011). WAGENSEIL, J. E. and R. P. MECHAM. 2009. Vascular Extracellular Matrix and Arterial Mechanics. Physiol Rev, 89(3), pp.957-989. WALDEN, R., G. J. L'ITALIEN, J. MEGERMAN and W. M. ABBOTT. 1980. Matched elastic properties and successful arterial grafting. Archives of surgery (Chicago, Ill. : 1960), 115(10), pp.1166-1169. WEINBERG, C. B. and E. BELL. 1986. A blood vessel model constructed from collagen and cultured vascular cells. Science, 231(4736), pp.397-400. WESTERHOF, N., N. STERGIOPULOS, M. I. M. NOBLE and N. STERGIOPULOS. 2010. Law of Laplace. Snapshots of Hemodynamics. Springer US, pp.45-48. WHITE, A., D. BURNS and T. W. CHRISTENSEN. 2006. Effective terminal sterilization using supercritical carbon dioxide. Journal of Biotechnology, 123(4), pp.504-515. WIGHT, T. 1989. Cell biology of arterial proteoglycans. Arterioscler Thromb Vasc Biol, 9(1), pp.1-20. WILCOX, H. E., S. A. KOROSSIS, C. BOOTH, K. G. WATTERSON, J. N. KEARNEY, J. FISHER and E. INGHAM. 2005. Biocompatibility and recellularization potential of an acellular porcine heart valve matrix. J Heart Valve Dis, 14(2), pp.228-36; discussion 236-7. WILLIAMS, R. M., W. R. ZIPFEL and W. W. WEBB. 2005. Interpreting Second-Harmonic Generation Images of Collagen I Fibrils. Biophysical Journal, 88(2), pp.1377-1386. WILSHAW S., LUO J., FISHER J., HOMER-VANNIASINKAM S and INGHAM E. 2014. Regenerative Potential of An Acellular Xenogeneic Small Diameter Artery In Vivo. In: TERMIS NA (Americas), Washington D.C. , 13th - 15th December. WILSHAW, S. P., J. N. KEARNEY, J. FISHER and E. INGHAM. 2006. Production of an acellular amniotic membrane matrix for use in tissue engineering. Tissue Eng, 12(8), pp.2117-29. WILSHAW, S. P., P. ROONEY, H. BERRY, J. N. KEARNEY, S. HOMER-VANNIASINKAM, J. FISHER and E. INGHAM. 2012. Development and characterization of acellular allogeneic arterial matrices. Tissue Eng Part A, 18(5-6), pp.471-83. WU, H. C., T. W. WANG, P. L. KANG, Y. H. TSUANG, J. S. SUN and F. H. LIN. 2007. Coculture of endothelial and smooth muscle cells on a collagen membrane in the development of a small-diameter vascular graft. Biomaterials, 28(7), pp.1385-92. WWW.COLUMBIA.EDU. 2011. Pressure volume relationship of artries and veins. Television advertisement, www.columbia.edu-. Screened WWW.INTECHOPEN.COM. 2011. arteriovenous graft in forearm Television advertisement, www.intechopen.com. Screened WWW.MAYFIELDCLINIC.COM. 2011. Stenotic Artery. Television advertisement, www.mayfieldclinic.com. Screened WWW.NHS.UK. 2011. CABG Suregry. Television advertisement, www.nhs.uk. Screened WWW.SHINONGLOBAL.COM. 2011. Femeropopliteal Bypass Graft. Television advertisement, www.shinonglobal.com. Screened WWW.VASCULARCONCEPTS.COM. 2011. artery layers. Television advertisement, www.vascularconcepts.com. Screened WWW.VEININFO.CO.UK. 2011. Thrombosis. Television advertisement. Screened WWW.VWMIN.ORG. 2011. Artherosclerrosis. Television advertisement, www.vwmin.org-. Screened WYSTRYCHOWSKI, W., T. N. MCALLISTER, K. ZAGALSKI, N. DUSSERRE, L. CIERPKA and N. L'HEUREUX. 2014. First human use of an allogeneic tissue-engineered vascular graft for hemodialysis access. Journal of Vascular Surgery, (0). ZARINS, C., D. GIDDENS, B. BHARADVAJ, V. SOTTIURAI, R. MABON and S. GLAGOV. 1983. Carotid bifurcation atherosclerosis. Quantitative correlation of plaque localization with flow velocity profiles and wall shear stress. Circ Res, 53(4), pp.502-514. ZHANG, J., S. BURROWS, C. GLEASON, M. A. MATTHEWS, M. J. DREWS, M. LABERGE and Y. H. AN. 2006a. Sterilizing Bacillus pumilus spores using supercritical carbon dioxide. Journal of Microbiological Methods, 66(3), pp.479-485. ZHANG, J., N. DALAL, C. GLEASON, M. A. MATTHEWS, L. N. WALLER, K. F. FOX, A. FOX, M. J. DREWS, M. LABERGE and Y. H. AN. 2006b. On the mechanisms of deactivation of Bacillus atrophaeus spores using supercritical carbon dioxide. The Journal of Supercritical Fluids, 38(2), pp.268-273. ZHANG, W. J., W. LIU, L. CUI and Y. CAO. 2007. Tissue engineering of blood vessel. J Cell Mol Med, 11(5), pp.945-57. ZHANG, Y., X. ZHANG, L. XU, S. WEI and M. ZHAI. 2014. Radiation cross-linked collagen/dextran dermal scaffolds: effects of dextran on cross-linking and degradation. Journal of Biomaterials Science, Polymer Edition, 26(3), pp.162-180. ZHAO, Y., S. ZHANG, J. ZHOU, J. WANG, M. ZHEN, Y. LIU, J. CHEN and Z. QI. 2010. The development of a tissue-engineered artery using decellularized scaffold and autologous ovine mesenchymal stem cells. Biomaterials, 31(2), pp.296-307. ZILLA, P. and H. P. GREISLER. 1999. Tissue engineering of vascular prosthetic grafts. R.G. Landes Co."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.680542"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/12037/1/Milton-Barker_JMB_MechanicalEngineering_PhD_2015.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cardiovascular disease is the highest cause of morbidity worldwide, encompassing blood vessel disorders such as coronary artery and peripheral arterial disease. For small diameter applications (less than 6 mm) a tissue engineered commercial product is yet to be produced. Previously, a process for the production of acellular porcine carotid arteries was developed which showed excellent potential for clinical translation as vascular bypass grafts. Medical products, however, need to be sterilised to a sterility assurance level of 10-6 before they can be used clinically. The aim of this thesis was firstly to produce acellular vascular grafts from porcine carotid arteries using previously developed decellularisation technology. Secondly, to develop robust methods capable of evaluating the effects of different sterilisation methods on the biological and mechanical characteristics of acellular vascular grafts and finally to determine the compatibility of the main stream industrially available sterilisation processes (Gamma and E-Beam irradiation and ethylene oxide treatment) with acellular vascular grafts. Decellularisation of porcine carotid arteries was evaluated by determination of DNA content and histology. Biocompatibility was assessed using contact cytotoxicity. Acellular arteries were then subjected to 30 kGy (25 kGy min) E-Beam or Gamma irradiation or ethylene oxide treatment. The effects of sterilisation were determined using histology, immunohistochemistry, second harmonic generation multiphoton imaging, differential scanning calorimetry, denatured collagen content and determination of mechanical properties compared to non-sterilised acellular arteries. Mechanical properties were assessed using uniaxial tensile testing at a low strain rate to failure and burst pressure and compliance testing Histologically, the architecture of the arteries was retained post decellularisation and DNA content was reduced by greater than 95 %. The arteries were not cytotoxic. Stress strain mechanics were also retained but compliance testing showed a significant reduction. Post sterilisation with both Gamma irradiation and E-beam irradiation, there was a significantly increased stiffness of the elastin and collagen modulus of the acellular arteries. Ethylene oxide treatment significantly increased the elastin and collagen modulus. E-Beam irradiation and ethylene oxide treatment reduced compliance excessively. Histology showed the architecture of gamma and E-beam sterilised arteries to be consistent with acellular arteries and that ethylene oxide treated arteries exhibited some layer separation. Multiphoton imaging showed damage to all sterilised samples with Gamma sterilised acellular arteries the least affected. There were no significant differences in denaturation temperature. These results were in partial agreement with previously reported data on the effects of Gamma and E-beam sterilisation on tendons. Gamma, E-beam [30 kGy] irradiation and ethylene oxide treatment caused detrimental effects to the mechanical properties of acellular porcine carotid arteries. E-beam irradiation and ethylene oxide treatment caused severe reduction in the compliance of acellular porcine carotid arteries. Compliance mismatch is a known failure mechanism of vascular grafts, therefore E-Beam irradiation and ethylene oxide treatment were not compatible with acellular vascular grafts. Gamma irradiation caused the least damaging effects and is the most likely candidate of the three that could potentially be optimised for sterilising acellular vascular grafts."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of Methods for Assessment of the Effects of Sterilisation on Acellular Vascular Grafts"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ingham, Eileen","Fisher, John","Stacy-Paul, Wilshaw"],"dc:creator":["Milton-Barker, Jake Christopher"],"dc:date":["2015-09"],"dc:date.issued":["2015-09"],"dc:description.abstract":["Cardiovascular disease is the highest cause of morbidity worldwide, encompassing blood vessel disorders such as coronary artery and peripheral arterial disease. For small diameter applications (less than 6 mm) a tissue engineered commercial product is yet to be produced. Previously, a process for the production of acellular porcine carotid arteries was developed which showed excellent potential for clinical translation as vascular bypass grafts. Medical products, however, need to be sterilised to a sterility assurance level of 10-6 before they can be used clinically. The aim of this thesis was firstly to produce acellular vascular grafts from porcine carotid arteries using previously developed decellularisation technology. Secondly, to develop robust methods capable of evaluating the effects of different sterilisation methods on the biological and mechanical characteristics of acellular vascular grafts and finally to determine the compatibility of the main stream industrially available sterilisation processes (Gamma and E-Beam irradiation and ethylene oxide treatment) with acellular vascular grafts. Decellularisation of porcine carotid arteries was evaluated by determination of DNA content and histology. Biocompatibility was assessed using contact cytotoxicity. Acellular arteries were then subjected to 30 kGy (25 kGy min) E-Beam or Gamma irradiation or ethylene oxide treatment. The effects of sterilisation were determined using histology, immunohistochemistry, second harmonic generation multiphoton imaging, differential scanning calorimetry, denatured collagen content and determination of mechanical properties compared to non-sterilised acellular arteries. Mechanical properties were assessed using uniaxial tensile testing at a low strain rate to failure and burst pressure and compliance testing Histologically, the architecture of the arteries was retained post decellularisation and DNA content was reduced by greater than 95 %. The arteries were not cytotoxic. Stress strain mechanics were also retained but compliance testing showed a significant reduction. Post sterilisation with both Gamma irradiation and E-beam irradiation, there was a significantly increased stiffness of the elastin and collagen modulus of the acellular arteries. Ethylene oxide treatment significantly increased the elastin and collagen modulus. E-Beam irradiation and ethylene oxide treatment reduced compliance excessively. Histology showed the architecture of gamma and E-beam sterilised arteries to be consistent with acellular arteries and that ethylene oxide treated arteries exhibited some layer separation. Multiphoton imaging showed damage to all sterilised samples with Gamma sterilised acellular arteries the least affected. There were no significant differences in denaturation temperature. These results were in partial agreement with previously reported data on the effects of Gamma and E-beam sterilisation on tendons. Gamma, E-beam [30 kGy] irradiation and ethylene oxide treatment caused detrimental effects to the mechanical properties of acellular porcine carotid arteries. E-beam irradiation and ethylene oxide treatment caused severe reduction in the compliance of acellular porcine carotid arteries. Compliance mismatch is a known failure mechanism of vascular grafts, therefore E-Beam irradiation and ethylene oxide treatment were not compatible with acellular vascular grafts. Gamma irradiation caused the least damaging effects and is the most likely candidate of the three that could potentially be optimised for sterilising acellular vascular grafts."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.680542"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/12037/1/Milton-Barker_JMB_MechanicalEngineering_PhD_2015.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/12037/"],"dc:relation.references":["ABBOTT, W. M., J. MEGERMAN, J. E. HASSON, G. L'ITALIEN and D. F. WARNOCK. 1987. Effect of compliance mismatch on vascular graft patency. Journal of Vascular Surgery, 5(2), pp.376-382. ANDROS, G., R. W. HARRIS, S. X. SALLES-CUNHA, L. B. DULAWA, R. W. OBLATH and R. L. APYAN. 1986. Arm veins for arterial revascularization of the leg: Arteriographic and clinical observations. Journal of Vascular Surgery, 4(5), pp.416-427. ANSI. 2011. ANSI/AAMI ST67 Sterilization of health care products Requirements and guidance for selecting a sterility assurance level (SAL) for products labeled 'sterile'. American National Standards Institute. ARIZONO, T., Y. IWAMOTO, K. OKUYAMA and Y. SUGIOKA. 1994. Ethylene oxide sterilization of bone grafts. Residual gas concentration and fibroblast toxicity. Acta Orthop Scand, 65(6), pp.640-2. BADYLAK, S. F., D. O. FREYTES and T. W. GILBERT. 2009. Extracellular matrix as a biological scaffold material: Structure and function. Acta Biomater, 5(1), pp.1-13. BALLESTRA, P. and J.-L. CUQ. 1998. Influence of Pressurized Carbon Dioxide on the Thermal Inactivation of Bacterial and Fungal Spores. LWT - Food Science and Technology, 31(1), pp.84-88. BALLYK, P. D., C. WALSH, J. BUTANY and M. OJHA. 1998. Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses. J Biomech, 31(3), pp.229-37. BARNES, C. P., S. A. SELL, E. D. BOLAND, D. G. SIMPSON and G. L. BOWLIN. 2007. Nanofiber technology: designing the next generation of tissue engineering scaffolds. Adv Drug Deliv Rev, 59(14), pp.1413-33. BASSIOUNY, H. S., S. WHITE, S. GLAGOV, E. CHOI, D. P. GIDDENS and C. K. ZARINS. 1992. Anastomotic intimal hyperplasia: Mechanical injury or flow induced. Journal of Vascular Surgery, 15(4), pp.708-717. BAULMANN, W. L. 1985. ELECTRON BEAM CURING OF UNSATURATED COATING MATERIALS. Patent number: BECHTOLD, J. E., D. T. EASTLUND, M. K. BUTTS, D. F. LAGERBORG and R. F. KYLE. 1994. The effects of freeze-drying and ethylene oxide sterilization on the mechanical properties of human patellar tendon. Am J Sports Med, 22(4), pp.562-6. BERGER, K., L. R. SAUVAGE, A. M. RAO and S. J. WOOD. 1972. Healing of arterial prostheses in man: its incompleteness. Ann Surg, 175(1), pp.118-27. BERGLUND, J. D., M. M. MOHSENI, R. M. NEREM and A. SAMBANIS. 2003. A biological hybrid model for collagen-based tissue engineered vascular constructs. Biomaterials, 24(7), pp.1241-1254. BOLLAND, F., S. KOROSSIS, S.-P. WILSHAW, E. INGHAM, J. FISHER, J. N. KEARNEY and J. SOUTHGATE. 2007. Development and characterisation of a full-thickness acellular porcine bladder matrix for tissue engineering. Biomaterials, 28(6), pp.1061-1070. BOOTH, C., S. A. KOROSSIS, H. E. WILCOX, K. G. WATTERSON, J. N. KEARNEY, J. FISHER and E. INGHAM. 2002. Tissue engineering of cardiac valve prostheses I: development and histological characterization of an acellular porcine scaffold. J Heart Valve Dis, 11(4), pp.457-62. BOU-GHARIOS, G., M. PONTICOS, V. RAJKUMAR and D. ABRAHAM. 2004. Extra-cellular matrix in vascular networks. Cell Proliferation, 37(3), pp.207-220. BOURASSA, M. G. 1994. Long-term vein graft patency. Current Opinion in Cardiology, 9(6), pp.685-691. BROCKBANK, K. M., W. R. MACLELLAN, J. XIE, S. HAMM-ALVAREZ, Z. CHEN and K. SCHENKE-LAYLAND. 2008. Quantitative second harmonic generation imaging of cartilage damage. Cell and Tissue Banking, 9(4), pp.299-307. BROTHERS, T. E., J. C. STANLEY, W. E. BURKEL and L. M. GRAHAM. 1990. Small-caliber polyurethane and polytetrafluoroethylene grafts: A comparative study in a canine aortoiliac model. J Biomed Mater Res, 24(6), pp.761-771. BRUCE ALBERTS, DENNIS BRAY, ALEXANDER JOHNSON, JULIAN LEWIS, MARTIN RAFF, KEITH ROBERTS and AND PETER WALTER. 2004. Essential Cell Biology. Garland Science CAMPBELL, D. G. and P. LI. 1999. Sterilization of HIV with irradiation: relevance to infected bone allografts. Aust N Z J Surg, 69(7), pp.517-21. CARLSON, B. E., J. C. ARCIERO and T. W. SECOMB. 2008. Theoretical model of blood flow autoregulation: roles of myogenic, shear-dependent, and metabolic responses. American Journal of Physiology - Heart and Circulatory Physiology, 295(4), pp.H1572-H1579. CHAKRABARTY, K. H., R. A. DAWSON, P. HARRIS, C. LAYTON, M. BABU, L. GOULD, J. PHILLIPS, I. LEIGH, C. GREEN, E. FREEDLANDER and S. MAC NEIL. 1999. Development of autologous human dermal-epidermal composites based on sterilized human allodermis for clinical use. Br J Dermatol, 141(5), pp.811-23. CHEUNG, D. T., N. PERELMAN, D. TONG and M. E. NIMNI. 1990. The effect of gamma-irradiation on collagen molecules, isolated alpha-chains, and crosslinked native fibers. J Biomed Mater Res, 24(5), pp.581-9. CHLUPÁC, J., E. FILOVÁ and L. BACÁKOVÁ. 2009. Blood vessel replacement: 50 years of development and tissue engineering paradigms in vascular surgery. Physiological research / Academia Scientiarum Bohemoslovaca, 58 Suppl 2, pp.S119-S139. COLLINS, R. G., R. VELJI, N. V. GUEVARA, M. J. HICKS, L. CHAN and A. L. BEAUDET. 2000. P-Selectin or Intercellular Adhesion Molecule (Icam)-1 Deficiency Substantially Protects against Atherosclerosis in Apolipoprotein E–Deficient Mice. The Journal of Experimental Medicine, 191(1), pp.189-194. COOPER, G. M. 2000. The Cell: A Molecular Approach. Sunderland (MA): Sinauer Associates. COURTMAN, D. W., C. A. PEREIRA, V. KASHEF, D. MCCOMB, J. M. LEE and G. J. WILSON. 1994. Development of a pericardial acellular matrix biomaterial: biochemical and mechanical effects of cell extraction. J Biomed Mater Res, 28(6), pp.655-66. CRAPO, P. M., T. W. GILBERT and S. F. BADYLAK. 2011. An overview of tissue and whole organ decellularization processes. Biomaterials, 32(12), pp.3233-3243. CYRUS, T., J. L. WITZTUM, D. J. RADER, R. TANGIRALA, S. FAZIO, M. F. LINTON and C. D. FUNK. 1999. Disruption of the 12/15-lipoxygenase gene diminishes atherosclerosis in apo E–deficient mice. The Journal of Clinical Investigation, 103(11), pp.1597-1604. DARDIK, H., N. MILLER, A. DARDIK, I. IBRAHIM, B. SUSSMAN, S. M. BERRY, F. WOLODIGER, M. KAHN and I. DARDIK. 1988. A decade of experience with the glutaraldehyde-tanned human umbilical cord vein graft for revascularization of the lower limb. J Vasc Surg, 7(2), pp.336-46. DARDIK, H., K. WENGERTER, F. QIN, A. PANGILINAN, F. SILVESTRI, F. WOLODIGER, M. KAHN, B. SUSSMAN and I. M. IBRAHIM. 2002. Comparative decades of experience with glutaraldehyde-tanned human umbilical cord vein graft for lower limb revascularization: an analysis of 1275 cases. J Vasc Surg, 35(1), pp.64-71. DAS, N., M. J. BRATBY, V. SHRIVASTAVA, A. J. CORNALL, C. R. DARBY, P. BOARDMAN, S. ANTHONY and R. UBEROI. 2011. Results of a seven-year, single-centre experience of the long-term outcomes of bovine ureter grafts used as novel conduits for haemodialysis fistulas. Cardiovasc Intervent Radiol, 34(5), pp.958-63. DAVIS, E. C. 1993. Endothelial cell connecting filaments anchor endothelial cells to the subjacent elastic lamina in the developing aortic intima of the mouse. Cell and Tissue Research, 272(2), pp.211-219. DEBELLE, L. and A. M. TAMBURRO. 1999. Elastin: molecular description and function. The International Journal of Biochemistry & Cell Biology, 31(2), pp.261-272. DERHAM, C., H. YOW, J. INGRAM, J. FISHER, E. INGHAM, S. A. KORROSIS and S. HOMER-VANNIASINKAM. 2008. Tissue engineering small-diameter vascular grafts: preparation of a biocompatible porcine ureteric scaffold. Tissue Eng Part A, 14(11), pp.1871-82. DESAI, M., A. M. SEIFALIAN and G. HAMILTON. 2011. Role of prosthetic conduits in coronary artery bypass grafting. European Journal of Cardio-thoracic Surgery, 40(2), pp.394-398. DEVIREDDY, R. V., M. R. NEIDERT, J. C. BISCHOF and R. T. TRANQUILLO. 2003. Cryopreservation of collagen-based tissue equivalents. I. Effect of freezing in the absence of cryoprotective agents. Tissue Eng, 9(6), pp.1089-100. DEWEESE, J. A., H. B. BARNER, E. B. MAHONEY and C. G. ROB. 1966. Autogenous venous bypass grafts and thromboendarterectomies for atherosclerotic lesions of the femoropopliteal arteries. Ann Surg, 163(2), pp.205-14. DINGEMANS, K. P., P. TEELING, J. H. LAGENDIJK and A. E. BECKER. 2000. Extracellular matrix of the human aortic media: An ultrastructural histochemical and immunohistochemical study of the adult aortic media. The Anatomical Record, 258(1), pp.1-14. DONG, Z. M., S. M. CHAPMAN, A. A. BROWN, P. S. FRENETTE, R. O. HYNES and D. D. WAGNER. 1998. The combined role of P- and E-selectins in atherosclerosis. The Journal of Clinical Investigation, 102(1), pp.145-152. EMA. 1996. Note for Guidance on Virus Validation Studies: The Design, Contribution and Interpretation of Studies Validating the Inactivation and Removal of Viruses. European Medicines Agency: Committee for Human Medicinal Products (CHMP) and the Biotechnology Working Party (BWP). EUROPE, C. 2004. European Pharmacopoeia 5.0: Vol-2. Council of Europe. EYRE, D. R., M. A. PAZ and P. M. GALLOP. 1984. Cross-linking in collagen and elastin. Annu Rev Biochem, 53, pp.717-48. F.D.A. 2007. Guidance for Industry and FDA Staff - Biological Indicator. Center for Devices and Radiological Health FEBBRAIO, M., E. A. PODREZ, J. D. SMITH, D. P. HAJJAR, S. L. HAZEN, H. F. HOFF, K. SHARMA and R. L. SILVERSTEIN. 2000. Targeted disruption of the class B scavenger receptor CD36 protects against atherosclerotic lesion development in mice. The Journal of Clinical Investigation, 105(8), pp.1049-1056. FIDELER, B. M., C. T. VANGSNESS, JR., T. MOORE, Z. LI and S. RASHEED. 1994. Effects of gamma irradiation on the human immunodeficiency virus. A study in frozen human bone-patellar ligament-bone grafts obtained from infected cadavera. J Bone Joint Surg Am, 76(7), pp.1032-5. FINEGOLD, J. A., P. ASARIA and D. P. FRANCIS. 2013. Mortality from ischaemic heart disease by country, region, and age: Statistics from World Health Organisation and United Nations. International Journal of Cardiology, 168(2), pp.934-945. FISHER, J., C. BOOTH and E. INGHAM. 2001. Decellularisation of matrices. Google Patents. FREYTES, D. O., R. M. STONER and S. F. BADYLAK. 2008. Uniaxial and biaxial properties of terminally sterilized porcine urinary bladder matrix scaffolds. J Biomed Mater Res B Appl Biomater, 84(2), pp.408-14. FUNG, Y. C. 1993. Biomechanics: mechanical properties of living tissues. 2nd ed. FUSSENEGGER, M., J. MEINHART, W. HOBLING, W. KULLICH, S. FUNK and G. BERNATZKY. 2003. Stabilized autologous fibrin-chondrocyte constructs for cartilage repair in vivo. Ann Plast Surg, 51(5), pp.493-8. GAGE, A. A. and J. BAUST. 1998. Mechanisms of tissue injury in cryosurgery. Cryobiology, 37(3), pp.171-86. GALILI, U. and K. SWANSON. 1991. Gene sequences suggest inactivation of alpha-1,3-galactosyltransferase in catarrhines after the divergence of apes from monkeys. Proc Natl Acad Sci U S A, 88(16), pp.7401-4. GEHRING, J. 1995. The influence of ionising radiation (Beta/gamma) on various polymers based on the result of the cytotoxicity test. Radiation Physics and Chemistry, 46(4–6, Part 1), pp.617-622. GERBI, B. J., J. A. ANTOLAK, F. C. DEIBEL, D. S. FOLLOWILL, M. G. HERMAN, P. D. HIGGINS, M. S. HUQ, D. N. MIHAILIDIS, E. D. YORKE, K. R. HOGSTROM and F. M. KHAN. 2009. Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25. Med Phys, 36(7), pp.3239-79. GILBERT, T. W., T. L. SELLARO and S. F. BADYLAK. 2006. Decellularization of tissues and organs. Biomaterials, 27(19), pp.3675-3683. GOISSIS, G., S. SUZIGAN, D. R. PARREIRA, J. V. MANIGLIA, D. M. BRAILE and S. RAYMUNDO. 2000. Preparation and Characterization of Collagen-Elastin Matrices From Blood Vessels Intended as Small Diameter Vascular Grafts. Artificial Organs, 24(3), pp.217-223. GOLDMAN, S., K. ZADINA, T. MORITZ, T. OVITT, G. SETHI, J. G. COPELAND, L. THOTTAPURATHU, B. KRASNICKA, N. ELLIS, R. J. ANDERSON, W. HENDERSON and V. A. C. S. GROUP. 2004. Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery: results from a Department of Veterans Affairs Cooperative Study. J Am Coll Cardiol, 44(11), pp.2149-56. GORHAM, S. D., S. SRIVASTAVA, D. A. FRENCH and R. SCOTT. 1993. The effect of gamma-ray and ethylene oxide sterilization on collagen-based wound-repair materials. Journal of Materials Science: Materials in Medicine, 4(1), pp.40-49. GOUK, S. S., T. M. LIM, S. H. TEOH and W. Q. SUN. 2008. Alterations of human acellular tissue matrix by gamma irradiation: histology, biomechanical property, stability, in vitro cell repopulation, and remodeling. J Biomed Mater Res B Appl Biomater, 84(1), pp.205-17. GRAINGER, D. J., P. R. KEMP, A. C. LIU, R. M. LAWN and J. C. METCALFE. 1994. Activation of transforming growth factor-[beta] is inhibited in transgenic apolipoprotein(a) mice. Nature, 370(6489), pp.460-462. GRASSL, E. D., T. R. OEGEMA and R. T. TRANQUILLO. 2002. Fibrin as an alternative biopolymer to type-I collagen for the fabrication of a media equivalent. J Biomed Mater Res, 60(4), pp.607-12. GRAY, H., C. M. GOSS and D. M. ALVARADO. 1973. Anatomy of the human body. Lea & Febiger Philadelphia. GREENWALD, S. E. and C. L. BERRY. 2000. Improving vascular grafts: the importance of mechanical and haemodynamic properties. The Journal of Pathology, 190(3), pp.292-299. GREISLER, H. P., E. D. ENDEAN, J. J. KLOSAK, J. ELLINGER, J. W. DENNIS, K. BUTTLE and D. U. KIM. 1988. Polyglactin 910/polydioxanone bicomponent totally resorbable vascular prostheses. Journal of vascular surgery : official publication, the Society for Vascular Surgery [and] International Society for Cardiovascular Surgery, North American Chapter, 7(5), pp.697-705. GREISLER, H. P., C. W. TATTERSALL, J. J. KLOSAK, E. A. CABUSAO, J. D. GARFIELD and D. U. KIM. 1991. Partially bioresorbable vascular grafts in dogs. Surgery, 110(4), pp.645-54; discussion 654-5. GRIEB, T. A., R. Y. FORNG, S. BOGDANSKY, C. RONHOLDT, B. PARKS, W. N. DROHAN, W. H. BURGESS and J. LIN. 2006. High-dose gamma irradiation for soft tissue allografts: High margin of safety with biomechanical integrity. J Orthop Res, 24(5), pp.1011-8. GRIMES, M., J. T. PEMBROKE and T. MCGLOUGHLIN. 2005. The effect of choice of sterilisation method on the biocompatibility and biodegradability of SIS (small intestinal submucosa). Biomed Mater Eng, 15(1-2), pp.65-71. GUILLIATT RS, DAVIES RPW, WILSHAW SP, AGGELI A. and INGHAM E. 2011. Peptide β-sheet self-assembly for the modification of acellular vascular grafts. European Cells and Materials,, 22, p57. H.S.C.I.C. 2011. Hospital episode statistics: Total procedures and interventions. HAMILTON, G., J. MEGERMAN, G. J. L'ITALIEN, D. F. WARNOCK, T. SCHMITZ-RIXEN, D. C. BREWSTER and W. M. ABBOTT. 1988. Prediction of aneurysm formation in vascular grafts of biologic origin. J Vasc Surg, 7(3), pp.400-8. HEGYI, L., J. N. SKEPPER, N. R. B. CARY and M. J. MITCHINSON. 1996. Foam cell apoptosis and the development of the lipid core of human atherosclerosis. The Journal of Pathology, 180(4), pp.423-429. HERTZER, N. R., E. G. BEVEN, J. R. YOUNG, P. J. O'HARA, W. F. RUSCHHAUPT, 3RD, R. A. GRAOR, V. G. DEWOLFE and L. C. MALJOVEC. 1984. Coronary artery disease in peripheral vascular patients. A classification of 1000 coronary angiograms and results of surgical management. Ann Surg, 199(2), pp.223-33. HIEMSTRA, H., M. TERSMETTE, A. H. VOS, J. OVER, M. P. VAN BERKEL and H. DE BREE. 1991. Inactivation of human immunodeficiency virus by gamma radiation and its effect on plasma and coagulation factors. Transfusion, 31(1), pp.32-9. HMS.HARVARD.EDU. 2011. Diseased Aorta. Television advertisement, hms.harvard.edu. Screened HOBURG, A., S. KESHLAF, T. SCHMIDT, M. SMITH, U. GOHS, C. PERKA, A. PRUSS and S. SCHEFFLER. 2011. Fractionation of high-dose electron beam irradiation of BPTB grafts provides significantly improved viscoelastic and structural properties compared to standard gamma irradiation. Knee Surg Sports Traumatol Arthrosc, 19(11), pp.1955-61. HOBURG, A., S. KESHLAF, T. SCHMIDT, M. SMITH, U. GOHS, C. PERKA, A. PRUSS and S. SCHEFFLER. 2015. High-dose electron beam sterilization of soft-tissue grafts maintains significantly improved biomechanical properties compared to standard gamma treatment. Cell and Tissue Banking, 16(2), pp.219-226. HOBURG, A. T., S. KESHLAF, T. SCHMIDT, M. SMITH, U. GOHS, C. PERKA, A. PRUSS and S. SCHEFFLER. 2010. Effect of electron beam irradiation on biomechanical properties of patellar tendon allografts in anterior cruciate ligament reconstruction. Am J Sports Med, 38(6), pp.1134-40. HODDE, J. and M. HILES. 2002. Virus safety of a porcine-derived medical device: evaluation of a viral inactivation method. Biotechnol Bioeng, 79(2), pp.211-6. HOENIG, M. R., G. R. CAMPBELL, B. E. ROLFE and J. H. CAMPBELL. 2005. Tissue-Engineered Blood Vessels: Alternative to Autologous Grafts? Arterioscler Thromb Vasc Biol, 25(6), pp.1128-1134. HOGSTROM, K. R. and P. R. ALMOND. 2006. Review of electron beam therapy physics. Phys Med Biol, 51(13), pp.R455-89. HOLMES, R. V. 2013. Assessing microbial proliferation and its prevention in the preparation of decellularised human dermis grafts. Submitted in accordance with the requirements for the degree of MSc by Research thesis, The University of Leeds HU, Y., Z. ZHANG, E. TORSNEY, A. R. AFZAL, F. DAVISON, B. METZLER and Q. XU. 2004. Abundant progenitor cells in the adventitia contribute to atherosclerosis of vein grafts in ApoE-deficient mice. The Journal of Clinical Investigation, 113(9), pp.1258-1265. HUMPHREY, J. D. and C. A. TAYLOR. 2008. Intracranial and Abdominal Aortic Aneurysms: Similarities, Differences, and Need for a New Class of Computational Models. Annual Review of Biomedical Engineering, 10(1), pp.221-246. HUYNH, T., G. ABRAHAM, J. MURRAY, K. BROCKBANK, P. O. HAGEN and S. SULLIVAN. 1999. Remodeling of an acellular collagen graft into a physiologically responsive neovessel. Nat Biotechnol, 17(11), pp.1083-6. ICH. 1997. Q5A(R1) Viral Safety Evaluation of Biotechnology Products Derived From Cell Lines of Human or Animal Origin. International Conference on Harmonisation. IJIRI, S., T. YAMAMURO, T. NAKAMURA, S. KOTANI and K. NOTOYA. 1994. Effect of sterilization on bone morphogenetic protein. J Orthop Res, 12(5), pp.628-36. INGHAM, E., J. FISHER and S. P. WILSHAW. 2010. Acellular vascular products. Patent number: WO/2012/042250. INTERNATIONAL STANDARD ISO/DIS 7198. 1998. Cardiovascular implants -- Tubular vascular prostheses. ISHIKAWA, H., M. SHIMODA, K. TAMAYA, A. YONEKURA, T. KAWANO and Y. OSAJIMA. 1997. Inactivation of Bacillus spores by the supercritical carbon dioxide micro-bubble method. Biosci Biotechnol Biochem, 61(6), pp.1022-3. ISO. 11135:2014 Sterilization of health-care products -- Ethylene oxide -- Requirements for the development, validation and routine control of a sterilization process for medical devices. ISO. 11137-2:2012. Sterilization of health care products — Radiation. Part 2: Establishing the sterilization dose. ISO. 22442-3:2007. Medical devices utilizing animal tissues and their derivatives. Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents. International Organization for Standardization. ISO. 10993-7:2008 ISO. Biological evaluation of medical devices. Ethylene oxide sterilization residuals. International Organization for Standardization. JACKSON, D. W., G. E. WINDLER and T. M. SIMON. 1990. Intraarticular reaction associated with the use of freeze-dried, ethylene oxide-sterilized bone-patella tendon-bone allografts in the reconstruction of the anterior cruciate ligament. Am J Sports Med, 18(1), pp.1-10; discussion 10-1. JAN, K.-M. 2010. Physiology : Hemodynamics [online]. [Accessed 2011]. Available from: http://www.columbia.edu/~kj3/Chapter2.htm. JESCHKE, M. G., V. HERMANUTZ, S. E. WOLF and G. B. KOVEKER. 1999. Polyurethane vascular prostheses decreases neointimal formation compared with expanded polytetrafluoroethylene. J Vasc Surg, 29(1), pp.168-76. JIANG, B., Z. WU, H. ZHAO, F. TANG, J. LU, Q. WEI and X. ZHANG. 2006. Electron beam irradiation modification of collagen membrane. Biomaterials, 27(1), pp.15-23. JOHNSON, C. P., T. HOW, M. SCRAGGS, C. R. WEST and J. BURNS. 2000. A biomechanical study of the human vertebral artery with implications for fatal arterial injury. Forensic Sci Int, 109(3), pp.169-82. JOHNSON, L. R. and J. H. BYRNE. 1998. Essential medical physiology. Lippincott-Raven. JORDY, A., R. HOFF-JORGENSEN, A. FLAGSTAD and E. LUND. 1975. Virus inactivation by ethylene oxide containing gases. Acta Vet Scand, 16(3), pp.379-87. KAKIUCHI, M., K. ONO, A. NISHIMURA and H. SHIOKAWA. 1996. Preparation of bank bone using defatting, freeze-drying and sterilisation with ethylene oxide gas. International Orthopaedics, 20(3), pp.142-146. KAKU, N., H. TSUMURA, M. KATAOKA, H. TAIRA and T. TORISU. 2002. Influence of aeration, storage, and rinsing conditions on residual ethylene oxide in freeze-dried bone allograft. J Orthop Sci, 7(2), pp.238-42. KAMIHIRA, M., M. TANIGUCHI and T. KOBAYASHI. 1987. Sterilization of Microorganisms with Supercritical Carbon Dioxide(Food & Nutrition). Agricultural and biological chemistry, 51(2), pp.407-412. KANNAN, R. Y., H. J. SALACINSKI, P. E. BUTLER, G. HAMILTON and A. M. SEIFALIAN. 2005. Current status of prosthetic bypass grafts: a review. J Biomed Mater Res B Appl Biomater, 74(1), pp.570-81. KAULITZKI, S. 2011. Cardiovascular System. Television advertisement, www.dreamstime.com. Screened KEARNEY, J. N., R. BOJAR and K. T. HOLLAND. 1993. Ethylene oxide sterilisation of allogenic bone implants. Clin Mater, 12(3), pp.129-35. KEARNEY, J. N., U. C. FRANKLIN, V. AGUIRREGOICOA and K. T. HOLLAND. 1989. Evaluation of ethylene oxide sterilization of tissue implants. J Hosp Infect, 13(1), pp.71-80. KENNEALEY, P. T., N. ELIAS, M. HERTL, D. S. KO, R. F. SAIDI, J. F. MARKMANN, E. E. SMOOT, D. A. SCHOENFELD and T. KAWAI. 2011. A prospective, randomized comparison of bovine carotid artery and expanded polytetrafluoroethylene for permanent hemodialysis vascular access. J Vasc Surg, 53(6), pp.1640-8. KER, R. F. 1981. Dynamic tensile properties of the plantaris tendon of sheep (Ovis aries). J Exp Biol, 93, pp.283-302. KHAIRA, H. S. and H. VOHRA. 2002. True aneurysm in a femoro-popliteal dacron graft - A case report and literature review. Cardiovascular Surgery, 10(6), pp.644-646. KLABUNDE, R. E. 2005. Cardiovascular Physiology Concepts. Lippincott Williams & Wilkins. KLINKERT, P., P. N. POST, P. J. BRESLAU and J. H. VAN BOCKEL. 2004. Saphenous vein versus PTFE for above-knee femoropopliteal bypass. A review of the literature. Eur J Vasc Endovasc Surg, 27(4), pp.357-62. KLOSE, B. Z. E., D-34431 MARSBERG, DE), GOHS, UWE (WEINBERGSTRASSE 68 F, D-01129 DRESDEN, DE), BARTEL, RAINER (STANGE STRASSE 2, 01324 DRESDEN, DE). 2007. A PROCESS FOR THE PREPARATION OF A PACKAGE COMPRISING A STERILISED BULK OF A DRUG SUBSTANCE, AND A PACKAGE COMPRISING A STERILISED BULK OF A PENICILLIN. Patent number: KNIGHT, R. L., C. BOOTH, H. E. WILCOX, J. FISHER and E. INGHAM. 2005. Tissue engineering of cardiac valves: re-seeding of acellular porcine aortic valve matrices with human mesenchymal progenitor cells. J Heart Valve Dis, 14(6), pp.806-13. KOCH, S., T. C. FLANAGAN, J. S. SACHWEH, F. TANIOS, H. SCHNOERING, T. DEICHMANN, V. ELLA, M. KELLOMAKI, N. GRONLOH, T. GRIES, R. TOLBA, T. SCHMITZ-RODE and S. JOCKENHOEVEL. 2010. Fibrin-polylactide-based tissue-engineered vascular graft in the arterial circulation. Biomaterials, 31(17), pp.4731-9. KONIG, G., T. N. MCALLISTER, N. DUSSERRE, S. A. GARRIDO, C. IYICAN, A. MARINI, A. FIORILLO, H. AVILA, W. WYSTRYCHOWSKI, K. ZAGALSKI, M. MARUSZEWSKI, A. L. JONES, L. CIERPKA, L. M. DE LA FUENTE and N. L'HEUREUX. 2009. Mechanical properties of completely autologous human tissue engineered blood vessels compared to human saphenous vein and mammary artery. Biomaterials, 30(8), pp.1542-1550. KOROSSIS, S. A., C. BOOTH, H. E. WILCOX, K. G. WATTERSON, J. N. KEARNEY, J. FISHER and E. INGHAM. 2002. Tissue engineering of cardiac valve prostheses II: biomechanical characterization of decellularized porcine aortic heart valves. J Heart Valve Dis, 11(4), pp.463-71. L'HEUREUX, N., N. DUSSERRE, A. MARINI, S. GARRIDO, L. DE LA FUENTE and T. MCALLISTER. 2007a. Technology insight: the evolution of tissue-engineered vascular grafts--from research to clinical practice. Nat Clin Pract Cardiovasc Med, 4(7), pp.389-95. L'HEUREUX, N., L. GERMAIN, R. LABBE and F. A. AUGER. 1993. In vitro construction of a human blood vessel from cultured vascular cells: a morphologic study. J Vasc Surg, 17(3), pp.499-509. L'HEUREUX, N., T. N. MCALLISTER and L. M. DE LA FUENTE. 2007b. Tissue-Engineered Blood Vessel for Adult Arterial Revascularization. New England Journal of Medicine, 357(14), pp.1451-1453. LAING, S. T. and D. D. MCPHERSON. 2009. Cardiovascular therapeutic uses of targeted ultrasound contrast agents. Cardiovasc Res, 83(4), pp.626-35. LANTZ, G. C., S. F. BADYLAK, A. C. COFFEY, L. A. GEDDES and W. E. BLEVINS. 1990. Small intestinal submucosa as a small-diameter arterial graft in the dog. J Invest Surg, 3(3), pp.217-27. LANTZ, G. C., S. F. BADYLAK, M. C. HILES, A. C. COFFEY, L. A. GEDDES, K. KOKINI, G. E. SANDUSKY and R. J. MORFF. 1993. Small intestinal submucosa as a vascular graft: a review. J Invest Surg, 6(3), pp.297-310. LEE, Y. and K. B. SONG. 2002. Effect of gamma-irradiation on the molecular properties of myoglobin. J Biochem Mol Biol, 35(6), pp.590-4. LEROUGE, S. and A. SIMMONS. 2012. Sterilisation of Biomaterials and Medical Devices. Elsevier Science. LI, A. C. A. C. and C. K. C. K. GLASS. 2002. The macrophage foam cell as a target for therapeutic intervention. Nature medicine, 8(11), pp.1235-1242. LIN, M.-G., T.-L. YANG, C.-T. CHIANG, H.-C. KAO, J.-N. LEE, W. LO, S.-H. JEE, Y.-F. CHEN, C.-Y. DONG and S.-J. LIN. 2006. Evaluation of dermal thermal damage by multiphoton autofluorescence and second-harmonic-generation microscopy. Journal of Biomedical Optics, 11(6), pp.064006-064006-6. LIU, M. and J. YANG. 2009. Electrokinetic effect of the endothelial glycocalyx layer on two-phase blood flow in small blood vessels. Microvascular Research, 78(1), pp.14-19. LOMAS, R. J., H. L. GILLAN, J. B. MATTHEWS, E. INGHAM and J. N. KEARNEY. 2001. An evaluation of the capacity of differently prepared demineralised bone matrices (DBM) and toxic residuals of ethylene oxide (EtOx) to provoke an inflammatory response in vitro. Biomaterials, 22(9), pp.913-21. LUCAS, A. D., K. MERRITT, V. M. HITCHINS, T. O. WOODS, S. G. MCNAMEE, D. B. LYLE and S. A. BROWN. 2003. Residual ethylene oxide in medical devices and device material. J Biomed Mater Res B Appl Biomater, 66(2), pp.548-52. LUSIS, A. J. 2000. Atherosclerosis. Nature, 407(6801), pp.233-241. MADDEN, R., G. LIPKOWITZ, B. BENEDETTO, A. KURBANOV, M. MILLER and L. BOW. 2002. Decellularized cadaver vein allografts used for hemodialysis access do not cause allosensitization or preclude kidney transplantation. Am J Kidney Dis, 40(6), pp.1240-3. MADDEN, R. L., G. S. LIPKOWITZ, B. J. BROWNE and A. KURBANOV. 2005. A comparison of cryopreserved vein allografts and prosthetic grafts for hemodialysis access. Ann Vasc Surg, 19(5), pp.686-91. MARANTO, A. R. and F. J. SCHOEN. 1988. Phosphatase enzyme activity is retained in glutaraldehyde treated bioprosthetic heart valves. ASAIO Trans, 34(3), pp.827-30. MARRECO, P. R., P. D. L. MOREIRA, S. C. GENARI and Â. M. MORAES. 2004. Effects of different sterilization methods on the morphology, mechanical properties, and cytotoxicity of chitosan membranes used as wound dressings. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 71B(2), pp.268-277. MARTIN, R. S., 3RD, W. H. EDWARDS, J. L. MULHERIN, JR., W. H. EDWARDS, JR., J. M. JENKINS and S. J. HOFF. 1994. Cryopreserved saphenous vein allografts for below-knee lower extremity revascularization. Ann Surg, 219(6), pp.664-70; discussion 670-2. MCALLISTER, T. N., M. MARUSZEWSKI, S. A. GARRIDO, W. WYSTRYCHOWSKI, N. DUSSERRE, A. MARINI, K. ZAGALSKI, A. FIORILLO, H. AVILA, X. MANGLANO, J. ANTONELLI, A. KOCHER, M. ZEMBALA, L. CIERPKA, L. M. DE LA FUENTE and N. L'HEUREUX. 2009. Effectiveness of haemodialysis access with an autologous tissue-engineered vascular graft: a multicentre cohort study. The Lancet, 373(9673), pp.1440-1446. MCDONNELL, G. E. 2007. Antisepsis, Disinfection, and Sterilization: Types, Action, and Resistance. ASM Press. MCPHERSON, T. B., H. LIANG, R. D. RECORD and S. F. BADYLAK. 2000. Galalpha(1,3)Gal epitope in porcine small intestinal submucosa. Tissue Eng, 6(3), pp.233-9. MERYMAN, H. T. 1960. General principles of freezing and freezing injury in cellular materials. Ann N Y Acad Sci, 85, pp.503-9. MESTAS, J. and K. LEY. 2008. Monocyte-Endothelial Cell Interactions in the Development of Atherosclerosis. Trends in Cardiovascular Medicine, 18(6), pp.228-232. MEYERS, M. A., P.-Y. CHEN, A. Y.-M. LIN and Y. SEKI. 2008. Biological materials: Structure and mechanical properties. Progress in Materials Science, 53(1), pp.1-206. MILLS, N. L. and C. T. EVERSON. 1989. Rigt gastroepiploic artery: A third arterial conduit for coronary artery bypass. The Annals of Thoracic Surgery, 47(5), pp.706-711. MIRSADRAEE, S., H. E. WILCOX, S. A. KOROSSIS, J. N. KEARNEY, K. G. WATTERSON, J. FISHER and E. INGHAM. 2006. Development and characterization of an acellular human pericardial matrix for tissue engineering. Tissue Eng, 12(4), pp.763-73. MITRA, A. K., D. M. GANGAHAR and D. K. AGRAWAL. 2006. Cellular, molecular and immunological mechanisms in the pathophysiology of vein graft intimal hyperplasia. Immunol Cell Biol, 84(2), pp.115-24. MOORE, T. M., E. GENDLER and E. GENDLER. 2004. Viruses adsorbed on musculoskeletal allografts are inactivated by terminal ethylene oxide disinfection. J Orthop Res, 22(6), pp.1358-61. MORINAGA, K., K. OKADOME, M. KUROKI, T. MIYAZAKI, Y. MUTO and K. INOKUCHI. 1985. Effect of wall shear stress on intimal thickening of arterially transplanted autogenous veins in dogs. Journal of Vascular Surgery, 2(3), pp.430-433. NAKAGAWA, Y., K. OTA, Y. SATO, S. TERAOKA and T. AGISHI. 1995. Clinical trial of new polyurethane vascular grafts for hemodialysis: compared with expanded polytetrafluoroethylene grafts. Artif Organs, 19(12), pp.1227-32. NATHER, A., N. YUSOF and N. HILMY. 2007. Radiation in Tissue Banking: Basic Science and Clinical Applications of Irradiated Tissue Allografts. World Scientific Publishing Company. NEVEN, E. and P. C. D'HAESE. 2011. Vascular Calcification in Chronic Renal Failure: What Have We Learned From Animal Studies? Circulation Research, 108(2), pp.249-264. NEWBY, A. C. and A. B. ZALTSMAN. 2000. Molecular mechanisms in intimal hyperplasia. The Journal of Pathology, 190(3), pp.300-309. NIKLASON, L. E., W. ABBOTT, J. GAO, B. KLAGGES, K. K. HIRSCHI, K. ULUBAYRAM, N. CONROY, R. JONES, A. VASANAWALA, S. SANZGIRI and R. LANGER. 2001. Morphologic and mechanical characteristics of engineered bovine arteries. J Vasc Surg, 33(3), pp.628-38. OKUHN, S. P., D. P. CONNELLY, N. CALAKOS, L. FERRELL, P. MAN-XIANG and J. GOLDSTONE. 1989. Does compliance mismatch alone cause neointimal hyperplasia? Journal of Vascular Surgery, 9(1), pp.35-45. OLDE DAMINK, L. H., P. J. DIJKSTRA, M. J. VAN LUYN, P. B. VAN WACHEM, P. NIEUWENHUIS and J. FEIJEN. 1995. Influence of ethylene oxide gas treatment on the in vitro degradation behavior of dermal sheep collagen. J Biomed Mater Res, 29(2), pp.149-55. OWEN, K., S. P. WILSHAW, S. HOMER-VANNIASINKAM, R. A. BOJAR, H. BERRY and E. INGHAM. 2012. Assessment of the antimicrobial activity of acellular vascular grafts. Eur J Vasc Endovasc Surg, 43(5), pp.573-81. PANKAJAKSHAN, D. and D. K. AGRAWAL. 2010. Scaffolds in tissue engineering of blood vessels. Canadian Journal of Physiology and Pharmacology, 88(9), pp.855-873. PARISI, A. and A. D. ANTOINE. 1974. Increased radiation resistance of vegetative Bacillus pumilus. Appl Microbiol, 28(1), pp.41-6. PARK, I. S., S.-H. KIM, Y. H. KIM, I. H. KIM and S. H. KIM. 2009. A Collagen/Smooth Muscle Cell-Incorporated Elastic Scaffold for Tissue-Engineered Vascular Grafts. Journal of Biomaterials Science, Polymer Edition, 20(11), pp.1645-1660. PARKER, W., S. SAADI, S. S. LIN, Z. E. HOLZKNECHT, M. BUSTOS and J. L. PLATT. 1996. Transplantation of discordant xenografts: a challenge revisited. Immunol Today, 17(8), pp.373-8. PHILLIPS, C. R. and S. KAYE. 1949. The sterilizing action of gaseous ethylene oxide; a review. Am J Hyg, 50(3), pp.270-9. PONTICELLI, C. 2012. The mechanisms of acute transplant rejection revisited. J Nephrol, 25(2), pp.150-8. PREVENTING-A-HEART-ATTACK.COM. 2011. Anatomy of the heart. Television advertisement. Screened PROLO, D. J., P. W. PEDROTTI and D. H. WHITE. 1980. Ethylene Oxide Sterilization of Bone, Dura Mater, and Fascia Lata for Human Transplantation. Neurosurgery, 6(5), pp.529-539. QIU, Q. Q., P. LEAMY, J. BRITTINGHAM, J. POMERLEAU, N. KABARIA and J. CONNOR. 2009. Inactivation of bacterial spores and viruses in biological material using supercritical carbon dioxide with sterilant. J Biomed Mater Res B Appl Biomater, 91(2), pp.572-8. RADER, D. J. and A. DAUGHERTY. 2008. Translating molecular discoveries into new therapies for atherosclerosis. Nature, 451(7181), pp.904-913. RANDON, C., B. JACOBS, F. DE RYCK, H. BEELE and F. VERMASSEN. 2010. Fifteen years of infrapopliteal arterial reconstructions with cryopreserved venous allografts for limb salvage. J Vasc Surg, 51(4), pp.869-77. ROLL, S., J. MULLER-NORDHORN, T. KEIL, H. SCHOLZ, D. EIDT, W. GREINER and S. N. WILLICH. 2008. Dacron vs. PTFE as bypass materials in peripheral vascular surgery--systematic review and meta-analysis. BMC Surg, 8, p22. ROTHSCHILD, M. F., A. RUVINSKY and C. A. B. INTERNATIONAL. 2011. The Genetics of the Pig. CABI. SAGOO, P., G. LOMBARDI and R. I. LECHLER. 2012. Relevance of Regulatory T cell Promotion of Donor-specific Tolerance in Solid Organ Transplantation. Frontiers in Immunology, 3. SAHA, P., B. MODARAI, J. HUMPHRIES, K. MATTOCK, M. WALTHAM, K. G. BURNAND and A. SMITH. 2009. The monocyte/macrophage as a therapeutic target in atherosclerosis. Current Opinion in Pharmacology, 9(2), pp.109-118. SALACINSKI, H. J., S. GOLDNER, A. GIUDICEANDREA, G. HAMILTON, A. M. SEIFALIAN, A. EDWARDS and R. J. CARSON. 2001. The Mechanical Behavior of Vascular Grafts: A Review. Journal of Biomaterials Applications, 15(3), pp.241-278. SARAZIN, P., X. ROY and B. D. FAVIS. 2004. Controlled preparation and properties of porous poly(-lactide) obtained from a co-continuous blend of two biodegradable polymers. Biomaterials, 25(28), pp.5965-5978. SARKAR, S., H. J. SALACINSKI, G. HAMILTON and A. M. SEIFALIAN. 2006. The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency. Eur J Vasc Endovasc Surg, 31(6), pp.627-36. SAUVAGE, L. R., K. E. BERGER, S. J. WOOD, S. G. YATES, II, J. C. SMITH and P. B. MANSFIELD. 1974. Interspecies healing of porous arterial prostheses: Observations, 1960 to 1974. Archives of Surgery, 109(5), pp.698-705. SCHANER, P. J., N. D. MARTIN, T. N. TULENKO, I. M. SHAPIRO, N. A. TAROLA, R. F. LEICHTER, R. A. CARABASI and P. J. DIMUZIO. 2004. Decellularized vein as a potential scaffold for vascular tissue engineering. Journal of Vascular Surgery, 40(1), pp.146-153. SCHENKE-LAYLAND, K. 2008. Non-invasive multiphoton imaging of extracellular matrix structures. Journal of Biophotonics, 1(6), pp.451-462. SCHERZER, T. and A. BECKERT. 1997. Electron beam curing of methacrylated gelatin studied by EPR and FT-Raman spectroscopy. Macromolecular Symposia, 119(1), pp.299-307. SCHMITZ-RIXEN, T., S. LEPIDI and G. HAMILTON. 1993. [Compliance: a fundamental biomechanical property in the maintenance of an arterial reconstruction?]. Ann Ital Chir, 64(1), pp.15-27. SCHOEN, F. J. 1987. Cardiac valve prostheses: pathological and bioengineering considerations. J Card Surg, 2(1), pp.65-108. SCHULZE-BAUER, C. A. J., P. REGITNIG and G. A. HOLZAPFEL. 2002. Mechanics of the human femoral adventitia including the high-pressure response. American Journal of Physiology - Heart and Circulatory Physiology, 282(6), pp.H2427-H2440. SCHWARTZ, H. E., M. J. MATAVA, F. S. PROCH, C. A. BUTLER, A. RATCLIFFE, M. LEVY and D. L. BUTLER. 2006. The Effect of Gamma Irradiation on Anterior Cruciate Ligament Allograft Biomechanical and Biochemical Properties in the Caprine Model at Time Zero and at 6 Months After Surgery. The American Journal of Sports Medicine, 34(11), pp.1747-1755. SEIFERT, K. B., D. ALBO, JR., H. KNOWLTON and D. J. LYMAN. 1979. Effect of elasticity of prosthetic wall on patency of small-diameter arterial prostheses. Surg Forum, 30, pp.206-8. SETO, A., C. J. GATT, JR. and M. G. DUNN. 2009. Improved tendon radioprotection by combined cross-linking and free radical scavenging. Clin Orthop Relat Res, 467(11), pp.2994-3001. SHANAHAN, C. M. 2013. Mechanisms of vascular calcification in CKD[mdash]evidence for premature ageing? Nat Rev Nephrol, 9(11), pp.661-670. SHEKHONIN, B. V., S. P. DOMOGATSKY, V. R. MUZYKANTOV, G. L. IDELSON and V. S. RUKOSUEV. 1985. Distribution of Type I, III, IV and V Collagen in Normal and Atherosclerotic Human Arterial Wall: Immunomorphological Characteristics. Collagen and Related Research, 5(4), pp.355-368. SIMON, P., M. T. KASIMIR, G. SEEBACHER, G. WEIGEL, R. ULLRICH, U. SALZER-MUHAR, E. RIEDER and E. WOLNER. 2003. Early failure of the tissue engineered porcine heart valve SYNERGRAFT™ in pediatric patients. European Journal of Cardio-thoracic Surgery, 23(6), pp.1002-1006. SMITH, C. W., I. S. YOUNG and J. N. KEARNEY. 1996. Mechanical properties of tendons: changes with sterilization and preservation. J Biomech Eng, 118(1), pp.56-61. SMITH, J. D., E. TROGAN, M. GINSBERG, C. GRIGAUX, J. TIAN and M. MIYATA. 1995. Decreased atherosclerosis in mice deficient in both macrophage colony-stimulating factor (op) and apolipoprotein E. Proceedings of the National Academy of Sciences, 92(18), pp.8264-8268. SOKAL, R. R. and F. J. ROHLF. 1981. Biometry: The Principles and Practice of Statistics in Biological Research. W. H. Freeman. SOLDANI, G., P. LOSI, M. BERNABEI, S. BURCHIELLI, D. CHIAPPINO, S. KULL, E. BRIGANTI and D. SPILLER. 2010. Long term performance of small-diameter vascular grafts made of a poly(ether)urethane-polydimethylsiloxane semi-interpenetrating polymeric network. Biomaterials, 31(9), pp.2592-605. SOTTIURAI, V. S., J. S. YAO, R. C. BATSON, S. L. SUE, R. JONES and Y. A. NAKAMURA. 1989. Distal anastomotic intimal hyperplasia: histopathologic character and biogenesis. Ann Vasc Surg, 3(1), pp.26-33. SPARK, J. I., S. YELURI, C. DERHAM, Y. T. WONG and D. LEITCH. 2008. Incomplete cellular depopulation may explain the high failure rate of bovine ureteric grafts. Br J Surg, 95(5), pp.582-5. SPILIMBERGO, S. and A. BERTUCCO. 2003. Non-thermal bacterial inactivation with dense CO(2). Biotechnol Bioeng, 84(6), pp.627-38. SPIRE, B., D. DORMONT, F. BARRE-SINOUSSI, L. MONTAGNIER and J. C. CHERMANN. 1985. Inactivation of lymphadenopathy-associated virus by heat, gamma rays, and ultraviolet light. Lancet, 1(8422), pp.188-9. STENMARK, K. R., E. NOZIK-GRAYCK, E. GERASIMOVSKAYA, A. ANWAR, M. LI, S. RIDDLE and M. FRID. 2006. The Adventitia: Essential Role in Pulmonary Vascular Remodeling. Comprehensive Physiology. John Wiley & Sons, Inc. SULLIVAN, R., A. C. FASSOLITIS, E. P. LARKIN, R. B. READ, JR. and J. T. PEELER. 1971. Inactivation of thirty viruses by gamma radiation. Appl Microbiol, 22(1), pp.61-5. SUMPIO, B. E., J. TIMOTHY RILEY and A. DARDIK. 2002. Cells in focus: endothelial cell. The International Journal of Biochemistry & Cell Biology, 34(12), pp.1508-1512. SUN, W. Q. and P. LEUNG. 2008. Calorimetric study of extracellular tissue matrix degradation and instability after gamma irradiation. Acta Biomater, 4(4), pp.817-26. SUZUKI, H. H., Y. Y. KURIHARA, M. M. TAKEYA, N. N. KAMADA, M. M. KATAOKA, K. K. JISHAGE, O. O. UEDA, H. H. SAKAGUCHI, T. T. HIGASHI, T. T. SUZUKI, Y. Y. TAKASHIMA, Y. Y. KAWABE, O. O. CYNSHI, Y. Y. WADA, M. M. HONDA, H. H. KURIHARA, H. H. ABURATANI, T. T. DOI, A. A. MATSUMOTO, S. S. AZUMA, T. T. NODA, Y. Y. TOYODA, H. H. ITAKURA, Y. Y. YAZAKI and T. T. KODAMA. 1997. A role for macrophage scavenger receptors in atherosclerosis and susceptibility to infection. Nature, 386(6622), pp.292-296. SWARTZ, D. D., J. A. RUSSELL and S. T. ANDREADIS. 2005. Engineering of fibrin-based functional and implantable small-diameter blood vessels. Am J Physiol Heart Circ Physiol, 288(3), pp.H1451-60. TATTERTON, M., S. P. WILSHAW, E. INGHAM and S. HOMER-VANNIASINKAM. 2012. The use of antithrombotic therapies in reducing synthetic small-diameter vascular graft thrombosis. Vasc Endovascular Surg, 46(3), pp.212-22. TEEBKEN, O. E. and A. HAVERICH. 2002. Tissue Engineering of Small Diameter Vascular Grafts. European Journal of Vascular and Endovascular Surgery, 23(6), pp.475-485. THEODOSSIOU, T. A., C. THRASIVOULOU, C. EKWOBI and D. L. BECKER. 2006. Second Harmonic Generation Confocal Microscopy of Collagen Type I from Rat Tendon Cryosections. Biophysical Journal, 91(12), pp.4665-4677. TILANUS, H. W., H. OBERTOP and H. VAN URK. 1985. Saphenous vein or PTFE for femoropopliteal bypass. A prospective randomized trial. Ann Surg, 202(6), pp.780-2. TILLMAN, B. W., S. K. YAZDANI, S. J. LEE, R. L. GEARY, A. ATALA and J. J. YOO. 2009. The in vivo stability of electrospun polycaprolactone-collagen scaffolds in vascular reconstruction. Biomaterials, 30(4), pp.583-8. TIMPL, R. 1996. Macromolecular organization of basement membranes. Current Opinion in Cell Biology, 8(5), pp.618-624. TIWARI, A., K. S. CHENG, H. SALACINSKI, G. HAMILTON and A. M. SEIFALIAN. 2003. Improving the Patency of Vascular Bypass Grafts: the Role of Suture Materials and Surgical Techniques on Reducing Anastomotic Compliance Mismatch. European Journal of Vascular and Endovascular Surgery, 25(4), pp.287-295. TIWARI, A., H. SALACINSKI, A. M. SEIFALIAN and G. HAMILTON. 2002. New prostheses for use in bypass grafts with special emphasis on polyurethanes. Cardiovascular Surgery, 10(3), pp.191-197. TRANQUILLO, R. T., T. S. GIRTON, B. A. BROMBEREK, T. G. TRIEBES and D. L. MOORADIAN. 1996. Magnetically orientated tissue-equivalent tubes: application to a circumferentially orientated media-equivalent. Biomaterials, 17(3), pp.349-57. TRUBEL, W., A. MORITZ, H. SCHIMA, F. RADERER, R. SCHERER, R. ULLRICH, U. LOSERT and P. POLTERAUER. 1994. Compliance and formation of distal anastomotic intimal hyperplasia in Dacron mesh tube constricted veins used as arterial bypass grafts. ASAIO Journal, 40(3), pp.M273-M278. TSCHOEKE, B., T. C. FLANAGAN, S. KOCH, M. S. HARWOKO, T. DEICHMANN, V. ELLA, J. S. SACHWEH, M. KELLOMAKI, T. GRIES, T. SCHMITZ-RODE and S. JOCKENHOEVEL. 2009. Tissue-engineered small-caliber vascular graft based on a novel biodegradable composite fibrin-polylactide scaffold. Tissue Eng Part A, 15(8), pp.1909-18. VALENTE, M., U. BORTOLOTTI and G. THIENE. 1985. Ultrastructural substrates of dystrophic calcification in porcine bioprosthetic valve failure. Am J Pathol, 119(1), pp.12-21. VAN DAMME, H., M. DEPREZ, E. CREEMERS and R. LIMET. 2005. Intrinsic structural failure of polyester (Dacron) vascular grafts. A general review. Acta Chirurgica Belgica, 105(3), pp.249-255. VAN DET, R. J., B. H. VRIENS, J. VAN DER PALEN and R. H. GEELKERKEN. 2009. Dacron or ePTFE for femoro-popliteal above-knee bypass grafting: short- and long-term results of a multicentre randomised trial. Eur J Vasc Endovasc Surg, 37(4), pp.457-63. VANGSNESS, C. T., JR., I. A. GARCIA, C. R. MILLS, M. A. KAINER, M. R. ROBERTS and T. M. MOORE. 2003. Allograft transplantation in the knee: tissue regulation, procurement, processing, and sterilization. Am J Sports Med, 31(3), pp.474-81. VEITH, F. J., C. M. MOSS, S. SPRAYREGEN and C. MONTEFUSCO. 1979. Preoperative saphenous venography in arterial reconstructive surgery of the lower extremity. Surgery, 85(3), pp.253-6. VESELY, I., R. NOSEWORTHY and G. PRINGLE. 1995. The hybrid xenograft/autograft bioprosthetic heart valve: In vivo evaluation of tissue extraction. The Annals of Thoracic Surgery, 60, Supplement 2(0), pp.S359-S364. W.H.O. 2011. World Health Organisation: Global Health Observatory - Number of deaths : World by cause (2000-2011). WAGENSEIL, J. E. and R. P. MECHAM. 2009. Vascular Extracellular Matrix and Arterial Mechanics. Physiol Rev, 89(3), pp.957-989. WALDEN, R., G. J. L'ITALIEN, J. MEGERMAN and W. M. ABBOTT. 1980. Matched elastic properties and successful arterial grafting. Archives of surgery (Chicago, Ill. : 1960), 115(10), pp.1166-1169. WEINBERG, C. B. and E. BELL. 1986. A blood vessel model constructed from collagen and cultured vascular cells. Science, 231(4736), pp.397-400. WESTERHOF, N., N. STERGIOPULOS, M. I. M. NOBLE and N. STERGIOPULOS. 2010. Law of Laplace. Snapshots of Hemodynamics. Springer US, pp.45-48. WHITE, A., D. BURNS and T. W. CHRISTENSEN. 2006. Effective terminal sterilization using supercritical carbon dioxide. Journal of Biotechnology, 123(4), pp.504-515. WIGHT, T. 1989. Cell biology of arterial proteoglycans. Arterioscler Thromb Vasc Biol, 9(1), pp.1-20. WILCOX, H. E., S. A. KOROSSIS, C. BOOTH, K. G. WATTERSON, J. N. KEARNEY, J. FISHER and E. INGHAM. 2005. Biocompatibility and recellularization potential of an acellular porcine heart valve matrix. J Heart Valve Dis, 14(2), pp.228-36; discussion 236-7. WILLIAMS, R. M., W. R. ZIPFEL and W. W. WEBB. 2005. Interpreting Second-Harmonic Generation Images of Collagen I Fibrils. Biophysical Journal, 88(2), pp.1377-1386. WILSHAW S., LUO J., FISHER J., HOMER-VANNIASINKAM S and INGHAM E. 2014. Regenerative Potential of An Acellular Xenogeneic Small Diameter Artery In Vivo. In: TERMIS NA (Americas), Washington D.C. , 13th - 15th December. WILSHAW, S. P., J. N. KEARNEY, J. FISHER and E. INGHAM. 2006. Production of an acellular amniotic membrane matrix for use in tissue engineering. Tissue Eng, 12(8), pp.2117-29. WILSHAW, S. P., P. ROONEY, H. BERRY, J. N. KEARNEY, S. HOMER-VANNIASINKAM, J. FISHER and E. INGHAM. 2012. Development and characterization of acellular allogeneic arterial matrices. Tissue Eng Part A, 18(5-6), pp.471-83. WU, H. C., T. W. WANG, P. L. KANG, Y. H. TSUANG, J. S. SUN and F. H. LIN. 2007. Coculture of endothelial and smooth muscle cells on a collagen membrane in the development of a small-diameter vascular graft. Biomaterials, 28(7), pp.1385-92. WWW.COLUMBIA.EDU. 2011. Pressure volume relationship of artries and veins. Television advertisement, www.columbia.edu-. Screened WWW.INTECHOPEN.COM. 2011. arteriovenous graft in forearm Television advertisement, www.intechopen.com. Screened WWW.MAYFIELDCLINIC.COM. 2011. Stenotic Artery. Television advertisement, www.mayfieldclinic.com. Screened WWW.NHS.UK. 2011. CABG Suregry. Television advertisement, www.nhs.uk. Screened WWW.SHINONGLOBAL.COM. 2011. Femeropopliteal Bypass Graft. Television advertisement, www.shinonglobal.com. Screened WWW.VASCULARCONCEPTS.COM. 2011. artery layers. Television advertisement, www.vascularconcepts.com. Screened WWW.VEININFO.CO.UK. 2011. Thrombosis. Television advertisement. Screened WWW.VWMIN.ORG. 2011. Artherosclerrosis. Television advertisement, www.vwmin.org-. Screened WYSTRYCHOWSKI, W., T. N. MCALLISTER, K. ZAGALSKI, N. DUSSERRE, L. CIERPKA and N. L'HEUREUX. 2014. First human use of an allogeneic tissue-engineered vascular graft for hemodialysis access. Journal of Vascular Surgery, (0). ZARINS, C., D. GIDDENS, B. BHARADVAJ, V. SOTTIURAI, R. MABON and S. GLAGOV. 1983. Carotid bifurcation atherosclerosis. Quantitative correlation of plaque localization with flow velocity profiles and wall shear stress. Circ Res, 53(4), pp.502-514. ZHANG, J., S. BURROWS, C. GLEASON, M. A. MATTHEWS, M. J. DREWS, M. LABERGE and Y. H. AN. 2006a. Sterilizing Bacillus pumilus spores using supercritical carbon dioxide. Journal of Microbiological Methods, 66(3), pp.479-485. ZHANG, J., N. DALAL, C. GLEASON, M. A. MATTHEWS, L. N. WALLER, K. F. FOX, A. FOX, M. J. DREWS, M. LABERGE and Y. H. AN. 2006b. On the mechanisms of deactivation of Bacillus atrophaeus spores using supercritical carbon dioxide. The Journal of Supercritical Fluids, 38(2), pp.268-273. ZHANG, W. J., W. LIU, L. CUI and Y. CAO. 2007. Tissue engineering of blood vessel. J Cell Mol Med, 11(5), pp.945-57. ZHANG, Y., X. ZHANG, L. XU, S. WEI and M. ZHAI. 2014. Radiation cross-linked collagen/dextran dermal scaffolds: effects of dextran on cross-linking and degradation. Journal of Biomaterials Science, Polymer Edition, 26(3), pp.162-180. ZHAO, Y., S. ZHANG, J. ZHOU, J. WANG, M. ZHEN, Y. LIU, J. CHEN and Z. QI. 2010. The development of a tissue-engineered artery using decellularized scaffold and autologous ovine mesenchymal stem cells. Biomaterials, 31(2), pp.296-307. ZILLA, P. and H. P. GREISLER. 1999. Tissue engineering of vascular prosthetic grafts. R.G. Landes Co."],"dcterms:accessrights":["public"],"dc:title":["Development of Methods for Assessment of the Effects of Sterilisation on Acellular Vascular Grafts"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T21:40:26Z"}