{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:12434"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:12434","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Direct current electrical resistance measurement techniques for assessment of colorectal cancer during laparoscopic surgery","abstract":"The next generation of surgical tools will employ intraoperative sensing technologies to provide real-time information to the surgeon. Sensing in this way may facilitate personalised tissue resections during cancer surgery, thereby reducing radicality and improving outcomes for the patient. This thesis details the development and testing of electrochemical based sensing techniques aimed at integration into the next generation of laparoscopic surgical tools. Literature reviewed as part of the work highlights the broad nature of surgically appropriate sensing technologies. Based on the features of simplicity and scalability, the biogalvanic tissue characterisation technique was explored as the most practically suitable candidate. Development and systematic testing of a biogalvanic measurement system with porcine tissues showed variation that is not explained using the current system model. Correlation with electrochemical measurements verified this unaccounted system complexity. Electrode polarisation and diffusion controlled reduction at the cathode limit the tissue specificity of the output metrics. An improved analytic model fitting technique was developed to reduce the influence of the electrodes. Through collaborative development of a numerical model of the system, the practical limitations of the biogalvanic techniques as a surgical sensor were realised. To mitigate these limitations, a novel galvanostatic technique for improved resistance characterisation was developed. Testing was conducted on ex vivo tissues, showing stability for relevant parametric variation. Surgical applicability was found from a practical perspective, with results showing low sensitivity to switching rate, current range and tissue contact conditions. Testing was also conducted on a number of freshly excised cancerous human colon samples. Measurements were centralised on each tumour and compared to a corresponding healthy region. Every case showed a highly significant difference between tissue types with cancerous tissues having a consistently lower resistance. These findings suggest that the proposed technique of multi-reference galvanostatic resistance characterisation may be a suitable candidate for integration into surgical tools for colorectal cancer surgery.","abstract_html":"The next generation of surgical tools will employ intraoperative sensing technologies to provide real-time information to the surgeon. Sensing in this way may facilitate personalised tissue resections during cancer surgery, thereby reducing radicality and improving outcomes for the patient. This thesis details the development and testing of electrochemical based sensing techniques aimed at integration into the next generation of laparoscopic surgical tools. Literature reviewed as part of the work highlights the broad nature of surgically appropriate sensing technologies. Based on the features of simplicity and scalability, the biogalvanic tissue characterisation technique was explored as the most practically suitable candidate. Development and systematic testing of a biogalvanic measurement system with porcine tissues showed variation that is not explained using the current system model. Correlation with electrochemical measurements verified this unaccounted system complexity. Electrode polarisation and diffusion controlled reduction at the cathode limit the tissue specificity of the output metrics. An improved analytic model fitting technique was developed to reduce the influence of the electrodes. Through collaborative development of a numerical model of the system, the practical limitations of the biogalvanic techniques as a surgical sensor were realised. To mitigate these limitations, a novel galvanostatic technique for improved resistance characterisation was developed. Testing was conducted on ex vivo tissues, showing stability for relevant parametric variation. Surgical applicability was found from a practical perspective, with results showing low sensitivity to switching rate, current range and tissue contact conditions. Testing was also conducted on a number of freshly excised cancerous human colon samples. Measurements were centralised on each tumour and compared to a corresponding healthy region. Every case showed a highly significant difference between tissue types with cancerous tissues having a consistently lower resistance. These findings suggest that the proposed technique of multi-reference galvanostatic resistance characterisation may be a suitable candidate for integration into surgical tools for colorectal cancer surgery.","abstract_has_math":false,"creators":["Chandler, James Henry"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Culmer, P.R.","Neville, A.","Jayne, D.G."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09","date_published":"2015-09","updated_at":"2026-11-18T21:40:56Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.682268"],"render_values":[{"text":"uk.bl.ethos.682268","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["483355"],"render_values":[{"text":"483355","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/12434/1/Final%20e-thesis.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A12434","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Culmer, P.R.","Neville, A.","Jayne, D.G."]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["CRUK"]},{"key":"dc:creator","label":"Author","values":["Chandler, James Henry"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09"]},{"key":"dc:date.issued","label":"Date","values":["2015-09"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Mechanical Engineering (Leeds)","Institute of Engineering Systems and Design (iESD)(Leeds)","Institute of Engineering Thermofluids, Surfaces & Interfaces (iETSI) (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/12434/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] Ferlay, J., H.R. Shin, F. Bray, D. Forman, C. Mathers and D.M. Parkin, GLOBOCAN 2008 v1.2, Cancer Incidence and Mortality Worldwide: IARC CancerBase No. 10. 2010. [2] CRUK, Data Table: Cancer incidence and mortality rates in the UK. [cited September 2015]; Available from: publications.cancerresearchuk.org. [3] Tufano, R.P. and E. Kandil, Considerations for personalized surgery in patients with papillary thyroid cancer. Thyroid, 2010. 20(7): p. 771-6. [4] Tiernan, J.P., I. Ansari, N.A. Hirst, P.A. Millner, T.A. Hughes and D.G. Jayne, Intra-operative tumour detection and staging in colorectal cancer surgery. Colorectal Disease, 2012. 14(9): p. e510-e20. [5] Stummer, W., U. Pichlmeier, T. Meinel, O.D. Wiestler, F. Zanella and H.-J. Reulen, Fluorescence-guided surgery with 5-aminolevulinic acid for resection of malignant glioma: a randomised controlled multicentre phase III trial. The Lancet Oncology, 2006. 7(5): p. 392-401. [6] van Dam, G.M., G. Themelis, L.M.A. Crane, N.J. Harlaar, R.G. Pleijhuis, W. Kelder, et al., Intraoperative tumor-specific fluorescence imaging in ovarian cancer by folate receptor-a targeting: first in-human results. Nat Med, 2011. 17(10): p. 1315-9. [7] Săftoiu, A., P. Vilmann, T. Ciurea, G.L. Popescu, A. Iordache, H. Hassan, et al., Dynamic analysis of EUS used for the differentiation of benign and malignant lymph nodes. Gastrointestinal Endoscopy, 2007. 66(2): p. 291-300. [8] Halter, R.J., A. Schned, J. Heaney, A. Hartov and K.D. Paulsen, Electrical Properties of Prostatic Tissues: I. Single Frequency Admittivity Properties. The Journal of Urology, 2009. 182(4): p. 1600-7. [9] CRUK, Types of Surgery for Bowel Cancer. [cited September 2015]; Available from: cancerresearchuk.org/about-cancer/type/bowel-cancer/treatment/surgery/which-surgery-for-bowel-cancer. [10] CRUK, All cancers combined Key Stats. 2015. [11] National Cancer Institute, Types of Treatment. [cited August 2014]; Available from: cancer.gov/about-cancer/treatment/types/stem-cell-transplant. [12] Smith, M.E. and D.G. Morton, The Digestive System: Systems of the Body Series: Elsevier Health Sciences UK. 2011. [13] Krstic, R.V., Human Microscopic Anatomy: An Atlas for Students of Medicine and Biology: Springer Berlin Heidelberg. 2013. [14] Fleming, M., S. Ravula, S.F. Tatishchev and H.L. Wang, Colorectal carcinoma: Pathologic aspects. Journal of Gastrointestinal Oncology, 2012. 3(3): p. 153-73. [15] About Cancer, Colon nodes. [Image cited March 2015]; Available from: aboutcancer.com/colon_nodes_grays.gif. [16] Cunningham, D., W. Atkin, H.-J. Lenz, H.T. Lynch, B. Minsky, B. Nordlinger, et al., Colorectal cancer. The Lancet, 2014. 375(9719): p. 1030-47. [17] Sobin, L.H., M.K. Gospodarowicz and C. Wittekind, TNM Classification of Malignant Tumours: Wiley. 2011. [18] CRUK, Diagram showing T stages of bowel cancer CRUK 276. [Image cited March 2015]; Available from: tinyurl.com/pf2r3v2. [19] About Cancer, Colon Stage. [Image cited April 2015]; Available from: aboutcancer.com/colon_stage.htm. [20] Beart, R.W., G.D. Steele, H.R. Menck, J.S. Chmiel, K.E. Ocwieja and D.P. Winchester, Management and survival of patients with adenocarcinoma of the colon and rectum: a national survey of the Commission on Cancer. Journal of the American College of Surgeons, 1995. 181(3): p. 225-36. [21] Poston, G.J., D. Beauchamp and T. Ruers, Textbook of Surgical Oncology: Taylor & Francis. 2007. [22] CRUK, Cancer Reseach UK's Research Strategy. 2008. p. 48. [23] Emmanuelm, Colon cancer 2. [Image cited 22 April 2014]; Available from: upload.wikimedia.org/wikipedia/commons/c/cc/Colon_cancer_2.jpg. [24] University of Utah, Adenocarcinoma arising in villous adenoma. [Image cited 22 April 2015]; Available from: pathologyoutlines.com/topic/colontumorvillousadenoma.html. [25] Junqueira, L.C.U. and J. Carneiro, Basic Histology: Text & Atlas: McGraw-Hill. 2005. [26] The, C.c.L.o.O.R.S.G., Laparoscopic surgery versus open surgery for colon cancer: short-term outcomes of a randomised trial. The Lancet Oncology, 2005. 6(7): p. 477-84. [27] Harrell, A.G. and B.T. Heniford, Minimally invasive abdominal surgery: lux et veritas past, present, and future. The American Journal of Surgery, 2005. 190(2): p. 239-43. [28] Medicare, D., Laparoscopic sureries. [Image cited 23 November 2014]; Available from: divjoninursinghome.com/laparoscopic_surgery.php. [29] Jacobson, B. and A. Murray, Medical Devices: Use and Safety: Churchill Livingstone. 2007. [30] MD, L., Laparoscopic Trocars. [cited 29/07/15 2015]; Available from: laparoscopic.md/instruments/trocar. [31] Mishra, R.K. and R. Mishra, Textbook of Practical Laparoscopic Surgery: Jaypee Brothers, Medical Publishers Pvt. Limited. 2013. [32] Jamieson, E.S., J.H. Chandler, P.R. Culmer, M. Manogue, M. Mon-Williams and R. Wilkie, Can Virtual Reality Trainers Improve the Compliance Discrimination Abilities of Trainee Surgeons? in Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, 2015: Milan, Italy [33] Remzi, F.H., H.T. Kirat, J.H. Kaouk and D.P. Geisler, Single-port laparoscopy in colorectal surgery. Colorectal Disease, 2008. 10(8): p. 823-6. [34] Wedmid, A., E. Llukani and D.I. Lee, Future perspectives in robotic surgery. BJU International, 2011. 108(6b): p. 1028-36. [35] Faust, R.A., Robotics in Surgery: History, Current and Future Applications: Nova Science Publishers. 2007. [36] Freschi, C., V. Ferrari, F. Melfi, M. Ferrari, F. Mosca and A. Cuschieri, Technical review of the da Vinci surgical telemanipulator. The International Journal of Medical Robotics and Computer Assisted Surgery, 2013. 9(4): p. 396-406. [37] Tholey, G., J.P. Desai and A.E. Castellanos, Force Feedback Plays a Significant Role in Minimally Invasive Surgery: Results and Analysis. Annals of Surgery, 2005. 241(1): p. 102-9. [38] Mayer, H., I. Nagy, A. Knoll, E. Braun, R. Bauernschmitt and R. Lange, Haptic Feedback in a Telepresence System for Endoscopic Heart Surgery. Presence, 2007. 16(5): p. 459-70. [39] Rao, P.P., P.P. Rao and S. Bhagwat, Single-incision laparoscopic surgery - current status and controversies. Journal of Minimal Access Surgery, 2011. 7(1): p. 6-16. [40] Autorino, R., R. Yakoubi, W.M. White, M. Gettman, M. De Sio, C. Quattrone, et al., Natural orifice transluminal endoscopic surgery (NOTES): where are we going? A bibliometric assessment. BJU International, 2013. 111(1): p. 11-6. [41] Nordlinger, C., The Internet of Things and the Operating Room of the Future. 2015. [42] Kopelman, Y., R.J. Lanzafame and D. Kopelman, Trends in Evolving Technologies in the Operating Room of the Future. JSLS : Journal of the Society of Laparoendoscopic Surgeons, 2013. 17(2): p. 171-3. [43] Moustris, G.P., S.C. Hiridis, K.M. Deliparaschos and K.M. Konstantinidis, Evolution of autonomous and semi-autonomous robotic surgical systems: a review of the literature. The International Journal of Medical Robotics and Computer Assisted Surgery, 2011. 7(4): p. 375-92. [44] Balog, J., L. Sasi-Szabó, J. Kinross, M.R. Lewis, L.J. Muirhead, K. Veselkov, et al., Intraoperative Tissue Identification Using Rapid Evaporative Ionization Mass Spectrometry. Science Translational Medicine, 2013. 5(194): p. 194ra93. [45] Fung, Y.C., Biomechanics: Mechanical Properties of Living Tissues: Springer New York. 2013. [46] Hayashi, K. Mechanical Properties of Soft Tissues and Arterial Walls. In: Holzapfel GA, Ogden RW, editors. Biomechanics of Soft Tissue in Cardiovascular Systems: Springer Vienna. 2014. p. 15-54. [47] Hoyt, K., B. Castaneda, M. Zhang, P. Nigwekar, P.A. di Sant'agnese, J.V. Joseph, et al., Tissue elasticity properties as biomarkers for prostate cancer. Cancer Biomark, 2008. 4(4-5): p. 213-25. [48] Krouskop, T.A., T.M. Wheeler, F. Kallel, B.S. Garra and T. Hall, Elastic Moduli of Breast and Prostate Tissues under Compression. Ultrasonic Imaging, 1998. 20(4): p. 260-74. [49] Phipps, S., T.H.J. Yang, F.K. Habib, R.L. Reuben and S.A. McNeill, Measurement of tissue mechanical characteristics to distinguish between benign and malignant prostatic disease. Urology, 2005. 66(2): p. 447-50. [50] Blanks, R.G., S.M. Moss, C.E. McGahan, M.J. Quinn and P.J. Babb, Effect of NHS breast screening programme on mortality from breast cancer in England and Wales, 1990-8: comparison of observed with predicted mortality2000. [51] Barton, M.B., R. Harris and S.W. Fletcher, Does this patient have breast cancer?: The screening clinical breast examination: should it be done? how? JAMA, 1999. 282(13): p. 1270-80. [52] Maxwell, J., White, J.R., David, P, O'Brien, III. Prostate Examination. In: Walker KH, Hall, W.D., Hurst, J.W, editor. Clinical Methods: The History, Physical, and Laboratory Examinations. 3rd ed. Boston: Butterworths. 1990. [53] Lai, W.M., D. Rubin and E. Krempl, Introduction to Continuum Mechanics: Butterworth-Heinemann/Elsevier. 2009. [54] Landau, L.D., L.P. Pitaevskii, A.M. Kosevich and E.M. Lifshitz, Theory of Elasticity: Elsevier Science. 2012. [55] Flügge, W., Viscoelasticity: Springer Berlin Heidelberg. 2013. [56] Mow, V.C. and W.M. Lai, Recent Developments in Synovial Joint Biomechanics. SIAM Review, 1980. 22(3): p. 275-317. [57] Tholey, G., A. Pillarisetti, W. Green and J. Desai. Design, Development, and Testing of an Automated Laparoscopic Grasper with 3-D Force Measurement Capability Medical Simulation. In: Cotin S, Metaxas D, editors.: Springer Berlin / Heidelberg. 2004. p. 38-48. [58] Zbyszewski, D., P. Polygerinos, L.D. Seneviratne and K. Althoefer, A novel MRI compatible air-cushion tactile sensor for Minimally Invasive Surgery. IEEE/RSJ International Conference on Intelligent Robots and Systems, 2009 (IROS) St. Louis, USA2009. p. 2647-52. [59] Zbyszewski, D., B. Challacombe, J. Li, L. Seneviratne, K. Althoefer, P. Dasgupta, et al., A comparative study between an improved novel air-cushion sensor and a wheeled probe for minimally invasive surgery. Journal of endourology / Endourological Society, 2010. 24(7): p. 1155-9. [60] Phipps, S., T.H.J. Yang, F.K. Habib, R.L. Reuben and S.A. McNeill, Measurement of the mechanical characteristics of benign prostatic tissue: A Novel method for assessing benign prostatic disease. Urology, 2005. 65(5): p. 1024-8. [61] Yang, T.H., S. Leung Sk Fau - Phipps, R.L. Phipps S Fau - Reuben, S.A. Reuben Rl Fau - McNeill, F.K. McNeill Sa Fau - Habib, A. Habib Fk Fau - Schnieder, et al., In-vitro dynamic micro-probing and the mechanical properties of human prostate tissues. (0928-7329 (Print)): p. [62] Hein, M., T.H. Yang, R.L. Reuben and E. R.W., Dynamic measurement of intraocular pressure using a mechanical model of the human eye. Medicine Meets Engineering, 2008. 133: p. 112-22. [63] Hien, M.R. and R.L. Reuben. Dynamic palpation device to evaluate IOP; simulation on a mechanical eyeball system. In: Dössel O, Schlegel W, editors. World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany: Springer Berlin Heidelberg. 2009. p. 339-42. [64] Scanlan, P., S.J. Hammer, D.W. Good, S. Phipps, G.D. Stewart, S.A. McNeill, et al., Development of a novel actuator for the dynamic palpation of soft tissue for use in the assessment of prostate tissue quality. Sensors and Actuators A: Physical, (0): p. [65] Kersaudy-Kerhoas, M., F. Amalou, A. Che, J. Kelly, Y. Liu, M.P.Y. Desmulliez, et al., Validation of a fully integrated platform and disposable microfluidic chips enabling parallel purification of genome segments for assembly. Biotechnology and Bioengineering, 2014. 111(8): p. 1627-37. [66] Gunn, C., Digital and Radiographic Imaging: A Practical Approach: Elsevier Health Sciences. 2008. [67] Szabo, T.L., Diagnostic Ultrasound Imaging: Inside Out: Elsevier Academic Press. 2004. [68] Taylor, L.S., B.C. Porter, D.J. Rubens and K.J. Parker, Three-dimensional sonoelastography: principles and practices. Physics in Medicine and Biology, 2000. 45(6): p. 1477-94. [69] Parker, K.J., M.M. Doyley and D.J. Rubens, Imaging the elastic properties of tissue: the 20 year perspective Physics in Medicine and Biology, 2011. 56: p. R1-R29. [70] Krouskop, T.A., D.R. Dougherty and F.S. Vinson, A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue. Journal of rehabilitation research and development, 1987. 24(2): p. 1-8. [71] Lerner, R.M., S.R. Huang and K.J. Parker, “Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissues. Ultrasound in Medicine & Biology, 1990. 16(3): p. 231-9. [72] Parker, K.J., S.R. Huang, R.A. Musulin and R.M. Lerner, Tissue response to mechanical vibrations for “sonoelasticity imaging”. Ultrasound in Medicine & Biology, 1990. 16(3): p. 241-6. [73] Ophir, J., I. Céspedes, H. Ponnekanti, Y. Yazdi and X. Li, Elastography: A quantitative method for imaging the elasticity of biological tissues. Ultrasonic Imaging, 1991. 13(2): p. 111-34. [74] Garra, B.S., E.I. Cespedes, J. Ophir, S.R. Spratt, R.A. Zuurbier, C.M. Magnant, et al., Elastography of breast lesions: initial clinical results. Radiology, 1997. 202(1): p. 79-86. [75] de Korte, C.L., E.I. Cespedes, A.F.W. van der Steen, G. Pasterkamp and N. Bom, Intravascular ultrasound elastography: assessment and imaging of elastic properties of diseased arteries and vulnerable plaque. European Journal of Ultrasound, 1998. 7(3): p. 219-24. [76] Ophir, J., S.K. Alam, B. Garra, F. Kallel, E. Konofagou, T. Krouskop, et al., Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1999. 213(3): p. 203-33. [77] Lindop, J.E., 2D and 3D Elastic Imaging Using Freehand Ultrasound. Pembroke College: Univerity of Cambridge; 2008. [78] Tanter, M., J. Bercoff, A. Athanasiou, T. Deffieux, J.-L. Gennisson, G. Montaldo, et al., Quantitative Assessment of Breast Lesion Viscoelasticity: Initial Clinical Results Using Supersonic Shear Imaging. Ultrasound in Medicine & Biology, 2008. 34(9): p. 1373-86. [79] Hoyt, K., K.J. Parker and D.J. Rubens, Real-Time Shear Velocity Imaging Using Sonoelastographic Techniques. Ultrasound in Medicine & Biology, 2007. 33(7): p. 1086-97. [80] Bhatia, K.S.S., C.C.M. Cho, Y.-H. Yuen, D.D. Rasalkar, A.D. King and A.T. Ahuja, Real-Time Qualitative Ultrasound Elastography of Cervical Lymph Nodes in Routine Clinical Practice: Interobserver Agreement and Correlation with Malignancy. Ultrasound in Medicine & Biology, 2010. 36(12): p. 1990-7. [81] Yoneda, M., K. Suzuki, S. Kato, K. Fujita, Y. Nozaki, K. Hosono, et al., Nonalcoholic Fatty Liver Disease: US-based Acoustic Radiation Force Impulse Elastography 1. Radiology, 2010. p. [82] Miklavčič, D., N. Pavšelj and F.X. Hart. Electric Properties of Tissues. Wiley Encyclopedia of Biomedical Engineering: John Wiley & Sons, Inc. 2006. [83] Gileadi, E., Physical Electrochemistry: Wiley. 2011. [84] Bard, A.J. and L.R. Faulkner, Electrochemical Methods: Fundamentals and Applications. New York: Wiley. 1980. [85] Schauble, M.K., H.D. Gullick and M.B. Habal, Variations in tissue electropotentials and their possible significance. Journal of Surgical Research, 1972. 12(5): p. 325-9. [86] Schauble, M.K. and M.B. Habal, Electropotentials of normal tissue. Journal of Surgical Research, 1969. 9(9): p. 513-5. [87] Gensler, W., Tissue Electropotentials in Kalanchoë blossfeldiana During Wound Healing. American Journal of Botany, 1978. 65(2): p. 152-7. [88] Burr, H.S., G.M. Smith and L.C. Strong, Bio-Electric Properties of Cancer-Resistant and Cancer-Susceptible Mice. The American Journal of Cancer, 1938. 32(2): p. 240-8. [89] Morris, D.M. Detection of Surface Electropotentials of Human Breast Lesions. In: Saha S, editor. Biomedical Engineering: I Recent Developments: Proceedings of the First Southern Biomedical Engineering Conference: Elsevier Science. 2013. p. 125-9. [90] Miklavcic, D., G. Sersa, S. Novaković and S. Rebersek, Tumor Bioelectric Potential and its Possible Exploitation for Tumor Growth Retardation. Electromagnetic Biology and Medicine, 1990. 9(2): p. 133-49. [91] Michaelis, L. and W. Davidoff, Methodisches und Sachliches zur elektrometrischen Bestimmung der Blutalkalescenz. . Zschr., 46:131. Biochem, 1912. 46: p. 131-50. [92] Michaelis, L. and A. Kramsztyk, Die Wasserstoffionenkonzentration der Gewebssafte. Biochem, 1914. 62: p. 180-5. [93] Buerk, D.G., Biosensors: Theory and Applications: Taylor & Francis. 1995. [94] Turner, A., I. Karube and G.S. Wilson, Biosensors: fundamentals and applications. 1987. p. [95] Shukla, P., Biosensors. 2014. [96] DropSens, Screen printed electrodes. [Image cited Available from: dropsens.com/en/screen_printed_electrodes_pag.html#modified_carbon_spes. [97] Chen, C., Q. Xie, D. Yang, H. Xiao, Y. Fu, Y. Tan, et al., Recent advances in electrochemical glucose biosensors: a review. RSC Advances, 2013. 3(14): p. 4473-91. [98] Li, J., S. Li and C.F. Yang, Electrochemical Biosensors for Cancer Biomarker Detection. Electroanalysis, 2012. 24(12): p. 2213-29. [99] Biomarkers Definitions Working, G., Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework. Clinical Pharmacology & Therapeutics, 2001. 69(3): p. 89-95. [100] Brenner, D.E. and D.P. Normolle, Biomarkers for Cancer Risk, Early Detection, and Prognosis: The Validation Conundrum. Cancer Epidemiology Biomarkers & Prevention, 2007. 16(10): p. 1918-20. [101] Vaupel, P., F. Kallinowski and P. Okunieff, Blood Flow, Oxygen and Nutrient Supply, and Metabolic Microenvironment of Human Tumors: A Review. Cancer Research, 1989. 49(23): p. 6449-65. [102] Kieninger, J., A. Dannenberg, K. Aravindalochanan, G. Jobst, E.O. Pettersen and G.A. Urban, Amperometric Oxygen Sensor Array with Novel Chronoamperometric Protocols for Hypoxic Tumor Cell Cultures. Solid-State Sensors, Actuators and Microsystems Conference, 2007 Transducers 2007 International2007. p. 1907-10. [103] Kotanen, C.N., F.G. Moussy, S. Carrara and A. Guiseppi-Elie, Implantable enzyme amperometric biosensors. Biosensors and Bioelectronics, 2012. 35(1): p. 14-26. [104] Grimnes, S. and O.G. Martinsen, Bioimpedance and Bioelectricity Basics: Academic Press. 2008. [105] Chen, J.H. and S.A. Adelman, Macroscopic model for solvated ion dynamics. The Journal of Chemical Physics, 1980. 72(4): p. 2819-31. [106] Nakahara, M. and K. Ibuki, Is the Walden product useful? The Journal of Physical Chemistry, 1986. 90(13): p. 3026-30. [107] Zwanzig, R., Dielectric Friction on a Moving Ion. II. Revised Theory. The Journal of Chemical Physics, 1970. 52(7): p. 3625-8. [108] Martinsen, O.G. and S. Grimnes, Bioimpedance and Bioelectricity Basics: Academic Press. 2000. [109] Burger, H.C. and R.v. Dongen, Specific Electric Resistance of Body Tissues. Physics in Medicine and Biology, 1961. 5(4): p. 431. [110] Kalvøy, H., G.K. Johnsen, O.G. Martinsen and S. Grimnes, New method for separation of electrode polarization impedance from measured tissue impedance. Open Biomed Eng J, 2011. 5: p. 6. [111] Faes, T.J., H.A. van der Meij, J.C. de Munck and R.M. Heethaar, The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. Physiological measurement, 1999. 20(4): p. R1-10. [112] Zanello, P. and R.S.o. Chemistry, Inorganic Electrochemistry: Theory, Practice and Applications: Royal Society of Chemistry. 2003. [113] Galvani, L., R.M. Green and G. Aldini, De Viribus Electricitatis in Motu Musculari Commentarius: A Translation of Luigi Galvani's de Viribus Electricitatisin Motu Musculari Commentarius: Licht. 1953. [114] Rao, J.R. and G. Richter, Implantable bio-electrochemical power sources. Naturwissenschaften, 1974. 61(5): p. 200-6. [115] Golberg, A., H.D. Rabinowitch and B. Rubinsky, Galvanic apparent internal impedance: An intrinsic tissue property. Biochemical and Biophysical Research Communications, 2009. 389(1): p. 168-71. [116] Golberg, A., S. Laufer, H.D. Rabinowitch and B. Rubinsky, In vivo non-thermal irreversible electroporation impact on rat liver galvanic apparent internal resistance. Physics in Medicine and Biology, 2011. 56(4): p. 951-63. [117] Golberg, A., S. Laufer, H.D. Rabinowitch and B. Rubinsky, In vivo non-thermal irreversible electroporation impact on rat liver galvanic apparent internal resistance. Physics in Medicine and Biology, 2011. 56(4): p. 951-63. [118] Spottorno, J., M. Multigner, G. Rivero, L. Álvarez, J.d.l. Venta and M. Santos, Time dependence of electrical bioimpedance on porcine liver and kidney under a 50 Hz ac current. Physics in Medicine and Biology, 2008. 53(6): p. 1701. [119] Technologies, A., Agilent Impedance Measurement Handbook. A guide to measurement technology and techniques. 4th ed. literature.agilent.com2014. [120] Schwan, H.P., Electric Characteristics of Tissues. Radiation and Environmental Biophysics, 1963. 1(3): p. 198-208. [121] Gabriel, C., S. Gabriel and E. Corthout, The dielectric properties of biological tissues: I. Literature survey. Physics in Medicine and Biology, 1996. 41(11): p. 2231. [122] Gabriel, S., R.W. Lau and C. Gabriel, The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Physics in Medicine and Biology, 1996b. 41(11): p. 2251. [123] Laufer, S., A. Ivorra, V.E. Reuter, B. Rubinsky and S.B. Solomon, Electrical impedance characterization of normal and cancerous human hepatic tissue. Physiological measurement, 2010. 31: p. 995-1009. [124] Chauveau, N., L. Hamzaoui, P. Rochaix, B. Rigaud, J.J. Voigt and J.P. Morucci, Ex vivo discrimination between normal and pathological tissues in human breast surgical biopsies using bioimpedance spectroscopy. Annals of the New York Academy of Sciences, 1999. 873: p. 42-50. [125] Jossinet, J., The impedivity of freshly excised human breast tissue. Physiological measurement, 1998. 19(1): p. 61. [126] Åberg, P., I. Nicander, U. Holmgren, P. Geladi and S. Ollmar, Assessment of skin lesions and skin cancer using simple electrical impedance indices. Skin Research and Technology, 2003. 9(3): p. 257-61. [127] Aberg, P., P. Geladi, I. Nicander, J. Hansson, U. Holmgren and S. Ollmar, Non-invasive and microinvasive electrical impedance spectra of skin cancer - a comparison between two techniques. Skin Research and Technology, 2005. 11(4): p. 281-6. [128] Dua, R., D.G. Beetner, W.V. Stoecker and D.C. Wunsch, II, Detection of basal cell carcinoma using electrical impedance and neural networks. Biomedical Engineering, IEEE Transactions on, 2004. 51(1): p. 66-71. [129] B. Blad, P.W., M. Jonsson, K. Lindstrom, An electrical impedance index to distinguish between normal and cancerous tissues. Journal of Medical Engineering & Technology, 1999. 23(2): p. 57-62. [130] Mongra, A.C., Commercial Biosensors: An outlook. Journal of Academic and Industrial Research, 2012. 1(6): p. 3. [131] TearLab, TearLab. [cited January 2015]; Available from: tearlab.com. [132] Zeev, M.S.-B., D.D. Miller and R. Latkany, Diagnosis of dry eye disease and emerging technologies. Clinical Ophthalmology (Auckland, NZ), 2014. 8: p. 581-90. [133] Zilico, What is ZedScan. [cited August 2015]; Available from: zilico.co.uk/zedscan/zedscan. [134] Brown, B.H., R.H. Smallwood, K.J. Boston, A.D. Blackett and J.A. Tidy, Electrical impedance measuring method for differentiating tissue types. In: Organization WIP, editor. G01N 33/487, 33/483, A61B 5/05 ed2001. [135] Abdul, S., B.H. Brown, P. Milnes and J.A. Tidy, The use of electrical impedance spectroscopy in the detection of cervical intraepithelial neoplasia. International Journal of Gynecological Cancer, 2006. 16(5): p. 1823-32. [136] Taruttis, A. and V. Ntziachristos, Translational Optical Imaging. American Journal of Roentgenology, 2012. 199(2): p. 263-71. [137] Bu, L., B. Shen and Z. Cheng, Fluorescent imaging of cancerous tissues for targeted surgery. Advanced Drug Delivery Reviews, 2014. 76: p. 21-38. [138] Sajja, H.K., M.P. East, H. Mao, Y.A. Wang, S. Nie and L. Yang, Development of multifunctional nanoparticles for targeted drug delivery and noninvasive imaging of therapeutic effect. Curr Drug Discov Technol, 2009. 6(1): p. 43-51. [139] Alander, J.T., I. Kaartinen, A. Laakso, T. P, #228, til, et al., A review of indocyanine green fluorescent imaging in surgery. Journal of Biomedical Imaging, 2012. 2012: p. 7-. [140] Recendt, Principle of photoacoustic imaging. [Image cited March 2015]; Available from: recendt.at/528_ENG_HTML.php. [141] Schaafsma, B.E., J.S.D. Mieog, M. Hutteman, J.R. van der Vorst, P.J.K. Kuppen, C.W.G.M. Löwik, et al., The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery. Journal of Surgical Oncology, 2011. 104(3): p. 323-32. [142] Kondo, Y., Y. Murayama, H. Konishi, R. Morimura, S. Komatsu, A. Shiozaki, et al., Fluorescent detection of peritoneal metastasis in human colorectal cancer using 5-aminolevulinic acid. International Journal of Oncology, 2014. p. [143] Filonenko, E.V., A.D. Kaprin, A.A. Raszhivina, A.N. Urlova and A.M. Nechipai, Fluorescence Diagnostics of Colon Malignant and Premalignant Lesions Using 5-Aminolevulinic Acid. International Journal of Photoenergy, 2014. 2014: p. 4. [144] Mehrmohammadi, M., S.J. Yoon, D. Yeager and S.Y. Emelianov, Photoacoustic Imaging for Cancer Detection and Staging. Current molecular imaging, 2013. 2(1): p. 89-105. [145] Zackrisson, S., S.M.W.Y. van de Ven and S.S. Gambhir, Light In and Sound Out: Emerging Translational Strategies for Photoacoustic Imaging. Cancer Research, 2014. 74(4): p. 979-1004. [146] Palmeri, M.L. and N.K. R.. What challenges must be overcome before ultrasound elasticity imaging is ready for the clinic? Imaging Med, 2011. 3(4): p. 11. [147] Curiel, L., R. Souchon, O. Rouvière, A. Gelet and J.Y. Chapelon, Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: Initial comparison with MRI. Ultrasound in Medicine & Biology, 2005. 31(11): p. 1461-8. [148] Clark, L.C., Monitor and control of blood and tissue oxygen tensions. Transactions of the American society for Articial Internal Organs 1956. 2: p. 8. [149] Golberg, A., H.D. Rabinowitch and B. Rubinsky, Zn/Cu- vegetative batteries, bioelectrical characterizations and primary cost analyses. J. Renewable and Sustainable Energy. Journal of Renewable and Sustainable Energy, 2010. 2(3): p. 11. [150] Li, G. and P. Miao. Theoretical Background of Electrochemical Analysis. Electrochemical Analysis of Proteins and Cells: Springer Berlin Heidelberg. 2013. p. 5-18. [151] Instruments, N., Specifications NI myDAQ. 2014. [152] Metrohm, Basic overview of the working principle of a potentiostat/galvanostat (PGSTAT) - Electrochemical cell setup. Autolab Application Note EC08. 2016. [153] Technologies, I., CompactStat: Hardware specifications. [cited Available from: ivium.nl/CompactStat%20Hardware%20specifications. [154] Schwarzenbach, J., Essentials of Control: Longman. 1996. [155] Moré, J. The Levenberg-Marquardt algorithm: Implementation and theory. In: Watson GA, editor. Numerical Analysis. New York: Springer-Verlag. 1977. p. 105-16. [156] Chandler, J.H., A. Hood, P.R. Culmer, D. Jayne and A. Neville, Technological assessment of the biogalvanic method for tissue characterization. Physiological Measurement, 2014. 35(2): p. 297. [157] Lal, H. and H.R. Thirsk, The anodic behaviour of copper in neutral and alkaline chloride solutions. J Chem Soc, 1953. (0): p. 2638-44. [158] Miklavčič, D., N. Pavšelj and F.X. Hart. Electric Properties of Tissues. In: Akay M, editor. Wiley Encyclopedia of Biomedical Engineering. New York: John Wiley & Sons, Inc. 2006. p. 3578-89. [159] Bard, A.J. and L.R. Faulkner, Electrochemical Methods: Fundamentals and Applications 2nd ed. 2nd ed. New York: Wiley. 2001. [160] Thomas, S., N. Birbilis, M.S. Venkatraman and I.S. Cole, Corrosion of Zinc as a Function of pH. Corrosion, 2012. 68(1): p. 015009-1--9. [161] García-Antón, J., A. Igual-Muñoz, J.L. Guiñón, V. Pérez-Herranz and J. Pertusa-Grau, Online Visualization of Corrosion Processes of Zinc and a Cu/Zn Galvanic Pair in Lithium Bromide Solutions. Corrosion, 2003. 59(2): p. 172-80. [162] Kear, G.A., C. Ponce de Leon Albarran and F.C. Walsh, Reduction of dissolved oxygen at a copper rotating disc electrode. Chemical Engineering Education, 2005. 39: p. 14-21. [163] Igual-Muñoz, A., J. García-Antón, J.L. Guiñón and V. Pérez-Herranz, Galvanic Study of Zinc and Copper in Lithium Bromide Solutions at Different Temperatures. Corrosion, 2001. 57(6): p. 516-22. [164] Grimnes, S. and O.G. Martinsen, Bioimpedance and Bioelectricity Basics. New York: Academic Press. 2000. [165] Halter, R.J., A. Hartov, K.D. Paulsen, A. Schned and J. Heaney, Genetic and least squares algorithms for estimating spectral EIS parameters of prostatic tissues. Physiol Meas, 2008. 29(6): p. S111-S23. [166] Gilányi, M., C. Ikrényi, J. Fekete, K. Ikrényi and A.G. Kovách, Ion concentrations in subcutaneous interstitial fluid: measured versus expected values. Am J Physiol, 1988. 255(3 Pt 2): p. 513-9. [167] de Silva, C.W., Mechatronics: An Integrated Approach: Taylor & Francis. 2004. [168] Carreau, A., B.E. Hafny-Rahbi, A. Matejuk, C. Grillon and C. Kieda, Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia. J Cell Mol Med, 2011. 15(6): p. 1239-53. [169] Sherwood, J.E., F. Stagnitti, M.J. Kokkinn and W.D. Williams, A standard table for predicting equilibrium dissolved oxygen concentrations in Salt Lakes dominated by sodium chloride. Int J Salt Lake Res, 1992. 1(1): p. 1-6. [170] Parthasarathy, A., S. Srinivasan, A.J. Appleby and C.R. Martin, Temperature Dependence of the Electrode Kinetics of Oxygen Reduction at the Platinum/Nafion® Interface—A Microelectrode Investigation. Journal of The Electrochemical Society, 1992. 139(9): p. 2530-7. [171] Vukmirovic, M.B., N. Vasiljevic, N. Dimitrov and K. Sieradzki, Diffusion-Limited Current Density of Oxygen Reduction on Copper. Journal of The Electrochemical Society, 2003. 150(1): p. B10-B5. [172] Tobias, C.W., M. Eisenberg and C.R. Wilke, Fiftieth Anniversary: Diffusion and Convection in Electrolysis—A Theoretical Review. Journal of The Electrochemical Society, 1952. 99(12): p. 359C-65C. [173] Chandler, J.H., P.R. Culmer, D.G. Jayne and A. Neville, Assessment of electrochemical properties of a biogalvanic system for tissue characterisation. Bioelectrochemistry, 2015. 101: p. 138-45. [174] Moisel, M., M.A.F.L. de Mele and W.D. Müller, Biomaterial Interface Investigated by Electrochemical Impedance Spectroscopy. Advanced Engineering Materials, 2008. 10(10): p. B33-B46. [175] Walter, G.W., Critical analysis of some electrochemical techniques including polarization resistance, for the study of zinc coating performance in near neutral chloride solutions. Corrosion Science, 1975. 15(1): p. 47-56. [176] Chandler, J.H., P.R. Culmer, D.G. Jayne and A. Neville, Assessment of electrochemical properties of a biogalvanic system for tissue characterisation. Bioelectrochemistry, 2015. 101(0): p. 138-45. [177] Press, W.H., Numerical Recipes 3rd Edition: The Art of Scientific Computing: Cambridge University Press. 2007. [178] Doig, P. and P.E.J. Flewitt, A Finite Difference Numerical Analysis of Galvanic Corrosion for Semi‐Infinite Linear Coplanar Electrodes. Journal of The Electrochemical Society, 1979. 126(12): p. 2057-63. [179] Munn, R.S. and O.F. Devereux, Numerical Modeling and Solution of Galvanic Corrosion Systems: Part I. Governing Differential Equation and Electrodic Boundary Conditions. Corrosion, 1991. 47(8): p. 612-8. [180] Saad, Y. and M.H. Schultz, GMRES: a generalized minimal residual algorithm for solving nonsymmetric linear systems. SIAM J Sci Stat Comput, 1986. 7(3): p. 856-69. [181] Hamann, C.H., A. Hamnett and W. Vielstich, Electrochemistry: Wiley. 2007. [182] Faes, T.J.C., H.A.v.d. Meij, J.C.d. Munck and R.M. Heethaar, The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. Physiol Meas, 1999. 20(4): p. R1. [183] Faes, T.J., H.A. van der Meij, J.C. de Munck and R.M. Heethaar, The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. Physiol Meas, 1999. 20(4): p. R1-10. [184] Wang, J., Electrochemical glucose biosensors. Chemical reviews, 2008. 108(2): p. 814-25. [185] Soper, S.A., K. Brown, A. Ellington, B. Frazier, G. Garcia-Manero, V. Gau, et al., Point-of-care biosensor systems for cancer diagnostics/prognostics. Biosensors and Bioelectronics, 2006. 21(10): p. 1932-42. [186] Brown, B.H., J.A. Tidy, K. Boston, A.D. Blackett, R.H. Smallwood and F. Sharp, Relation between tissue structure and imposed electrical current flow in cervical neoplasia. The Lancet, 2000. 355(9207): p. 892-5. [187] Tidy, J.A., B.H. Brown, T.J. Healey, S. Daayana, M. Martin, W. Prendiville, et al., Accuracy of detection of high-grade cervical intraepithelial neoplasia using electrical impedance spectroscopy with colposcopy. BJOG: An International Journal of Obstetrics & Gynaecology, 2013. 120(4): p. 400-11. [188] Scribner, L.L. and S.R. Taylor, The Measurement and Correction of Electrolyte Resistance in Electrochemical Tests. Baltimore: ASTM. 1990. [189] Hack, H.P., P.J. Moran and J.R. Scully. Influence of Electrolyte Resistance on Electrochemical Measurements and Proceedures to Minimize or Compensate for Resistance Errors. In: 1056 AS, Scribner LL, Taylor SR, editors. The Measurement and Correction of Electrolyte Resistance in Electrochemical Tests. Philadelphia: American Society for Testing and Materials. 1990. p. 5-26. [190] Britz, D., iR elimination in electrochemical cells. Journal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1978. 88(3): p. 309-52. [191] Barnartt, S., Primary Current Distribution Around Capillary Tips Used in the Measurement of Electrolytic Polarization. Journal of The Electrochemical Society, 1952. 99(12): p. 549-53. [192] Barnartt, S., Magnitude of IR‐Drop Corrections in Electrode Polarization Measurements Made with a Luggin‐Haber Capillary. Journal of The Electrochemical Society, 1961. 108(1): p. 102-4. [193] Hong, S.H., C. Kraiya, M.W. Lehmann and D.H. Evans, Evaluation of uncompensated solution resistance for electrodes with spherical-cap geometry. Anal Chem, 2000. 72(3): p. 454-8. [194] McIntyre, J.D.E. and W.F. Peck, An Interrupter Technique for Measuring the Uncompensated Resistance of Electrode Reactions under Potentiostatic Control. Journal of The Electrochemical Society, 1970. 117(6): p. 747-51. [195] Williams, L.F.G. and R.J. Taylor, iR correction: Part I. A computerised interrupt method. Journal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1980. 108(3): p. 293-303. [196] Herrmann, C.C., G.G. Perrault and A.A. Pilla, Dual reference electrode for electrochemical pulse studies. Analytical Chemistry, 1968. 40(7): p. 1173-4. [197] Pallás-Areny, R. and J.G. Webster. Signal Conditioning for Resistive Sensors. Sensors and Signal Conditioning, Second Edition: John Wiley & Sons, Limited. 2006. p. 133-206. [198] Jha, C. and A. Sanchez. Microprocessor Temperature Sensing and Thermal Management. Thermal Sensors: Principles and Applications for Semiconductor Industries: Springer New York. 2015. [199] Haglund, W.D. and M.H. Sorg. Postmortem changes in soft tissues. Forensic Taphonomy: The Postmortem Fate of Human Remains: Taylor & Francis. 1996. p. 151-64. [200] Haemmerich, D., O.R. Ozkan, J.Z. Tsai, S.T. Staelin, S. Tungjitkusolmun, D.M. Mahvi, et al., Changes in electrical resistivity of swine liver after occlusion and postmortem. Medical and Biological Engineering and Computing, 2002. 40(1): p. 29-33. [201] Mortimer, J.T., D. Kaufman and U. Roessmann, Intramuscular electrical stimulation: Tissue damage. Annals of Biomedical Engineering, 1980. 8(3): p. 235-44. [202] Chandler, J.H., A. Hood, P.R. Culmer, D. Jayne and A. Neville, A bio-galvanic approach to tissue characterisation: technological considerations. in Hamlyn Symposium on Medical Robotics, 2013: London, UK [203] Chandler, J.H., D.G. Jayne, A. Neville and P.R. Culmer, A novel multiple electrode direct current technique for characterisation of tissue resistance during surgery. in Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, 2015: Milan, Italy [204] Chandler, J.H., P.R. Culmer, D.G. Jayne and A. Neville, A time-dependent model for improved biogalvanic tissue characterisation. Medical Engineering & Physics: p. [205] Rutherford, D.E., Vector Methods Applied to Differential Geometry, Mechanics, and Potential Theory: Dover Publications. 2004."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.682268"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["483355"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/12434/1/Final%20e-thesis.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The next generation of surgical tools will employ intraoperative sensing technologies to provide real-time information to the surgeon. Sensing in this way may facilitate personalised tissue resections during cancer surgery, thereby reducing radicality and improving outcomes for the patient. This thesis details the development and testing of electrochemical based sensing techniques aimed at integration into the next generation of laparoscopic surgical tools. Literature reviewed as part of the work highlights the broad nature of surgically appropriate sensing technologies. Based on the features of simplicity and scalability, the biogalvanic tissue characterisation technique was explored as the most practically suitable candidate. Development and systematic testing of a biogalvanic measurement system with porcine tissues showed variation that is not explained using the current system model. Correlation with electrochemical measurements verified this unaccounted system complexity. Electrode polarisation and diffusion controlled reduction at the cathode limit the tissue specificity of the output metrics. An improved analytic model fitting technique was developed to reduce the influence of the electrodes. Through collaborative development of a numerical model of the system, the practical limitations of the biogalvanic techniques as a surgical sensor were realised. To mitigate these limitations, a novel galvanostatic technique for improved resistance characterisation was developed. Testing was conducted on ex vivo tissues, showing stability for relevant parametric variation. Surgical applicability was found from a practical perspective, with results showing low sensitivity to switching rate, current range and tissue contact conditions. Testing was also conducted on a number of freshly excised cancerous human colon samples. Measurements were centralised on each tumour and compared to a corresponding healthy region. Every case showed a highly significant difference between tissue types with cancerous tissues having a consistently lower resistance. These findings suggest that the proposed technique of multi-reference galvanostatic resistance characterisation may be a suitable candidate for integration into surgical tools for colorectal cancer surgery."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Direct current electrical resistance measurement techniques for assessment of colorectal cancer during laparoscopic surgery"]}]}],"canonical_facts":{"dc:contributor.advisor":["Culmer, P.R.","Neville, A.","Jayne, D.G."],"dc:contributor.sponsor":["CRUK"],"dc:creator":["Chandler, James Henry"],"dc:date":["2015-09"],"dc:date.issued":["2015-09"],"dc:description.abstract":["The next generation of surgical tools will employ intraoperative sensing technologies to provide real-time information to the surgeon. Sensing in this way may facilitate personalised tissue resections during cancer surgery, thereby reducing radicality and improving outcomes for the patient. This thesis details the development and testing of electrochemical based sensing techniques aimed at integration into the next generation of laparoscopic surgical tools. Literature reviewed as part of the work highlights the broad nature of surgically appropriate sensing technologies. Based on the features of simplicity and scalability, the biogalvanic tissue characterisation technique was explored as the most practically suitable candidate. Development and systematic testing of a biogalvanic measurement system with porcine tissues showed variation that is not explained using the current system model. Correlation with electrochemical measurements verified this unaccounted system complexity. Electrode polarisation and diffusion controlled reduction at the cathode limit the tissue specificity of the output metrics. An improved analytic model fitting technique was developed to reduce the influence of the electrodes. Through collaborative development of a numerical model of the system, the practical limitations of the biogalvanic techniques as a surgical sensor were realised. To mitigate these limitations, a novel galvanostatic technique for improved resistance characterisation was developed. Testing was conducted on ex vivo tissues, showing stability for relevant parametric variation. Surgical applicability was found from a practical perspective, with results showing low sensitivity to switching rate, current range and tissue contact conditions. Testing was also conducted on a number of freshly excised cancerous human colon samples. Measurements were centralised on each tumour and compared to a corresponding healthy region. Every case showed a highly significant difference between tissue types with cancerous tissues having a consistently lower resistance. These findings suggest that the proposed technique of multi-reference galvanostatic resistance characterisation may be a suitable candidate for integration into surgical tools for colorectal cancer surgery."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.682268"],"dc:identifier.grantnumber":["483355"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/12434/1/Final%20e-thesis.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["School of Mechanical Engineering (Leeds)","Institute of Engineering Systems and Design (iESD)(Leeds)","Institute of Engineering Thermofluids, Surfaces & Interfaces (iETSI) (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/12434/"],"dc:relation.references":["[1] Ferlay, J., H.R. Shin, F. Bray, D. Forman, C. Mathers and D.M. Parkin, GLOBOCAN 2008 v1.2, Cancer Incidence and Mortality Worldwide: IARC CancerBase No. 10. 2010. [2] CRUK, Data Table: Cancer incidence and mortality rates in the UK. [cited September 2015]; Available from: publications.cancerresearchuk.org. [3] Tufano, R.P. and E. Kandil, Considerations for personalized surgery in patients with papillary thyroid cancer. Thyroid, 2010. 20(7): p. 771-6. [4] Tiernan, J.P., I. Ansari, N.A. Hirst, P.A. Millner, T.A. Hughes and D.G. Jayne, Intra-operative tumour detection and staging in colorectal cancer surgery. Colorectal Disease, 2012. 14(9): p. e510-e20. [5] Stummer, W., U. Pichlmeier, T. Meinel, O.D. Wiestler, F. Zanella and H.-J. Reulen, Fluorescence-guided surgery with 5-aminolevulinic acid for resection of malignant glioma: a randomised controlled multicentre phase III trial. The Lancet Oncology, 2006. 7(5): p. 392-401. [6] van Dam, G.M., G. Themelis, L.M.A. Crane, N.J. Harlaar, R.G. Pleijhuis, W. Kelder, et al., Intraoperative tumor-specific fluorescence imaging in ovarian cancer by folate receptor-a targeting: first in-human results. Nat Med, 2011. 17(10): p. 1315-9. [7] Săftoiu, A., P. Vilmann, T. Ciurea, G.L. Popescu, A. Iordache, H. Hassan, et al., Dynamic analysis of EUS used for the differentiation of benign and malignant lymph nodes. Gastrointestinal Endoscopy, 2007. 66(2): p. 291-300. [8] Halter, R.J., A. Schned, J. Heaney, A. Hartov and K.D. Paulsen, Electrical Properties of Prostatic Tissues: I. Single Frequency Admittivity Properties. The Journal of Urology, 2009. 182(4): p. 1600-7. [9] CRUK, Types of Surgery for Bowel Cancer. [cited September 2015]; Available from: cancerresearchuk.org/about-cancer/type/bowel-cancer/treatment/surgery/which-surgery-for-bowel-cancer. [10] CRUK, All cancers combined Key Stats. 2015. [11] National Cancer Institute, Types of Treatment. [cited August 2014]; Available from: cancer.gov/about-cancer/treatment/types/stem-cell-transplant. [12] Smith, M.E. and D.G. Morton, The Digestive System: Systems of the Body Series: Elsevier Health Sciences UK. 2011. [13] Krstic, R.V., Human Microscopic Anatomy: An Atlas for Students of Medicine and Biology: Springer Berlin Heidelberg. 2013. [14] Fleming, M., S. Ravula, S.F. Tatishchev and H.L. Wang, Colorectal carcinoma: Pathologic aspects. Journal of Gastrointestinal Oncology, 2012. 3(3): p. 153-73. [15] About Cancer, Colon nodes. [Image cited March 2015]; Available from: aboutcancer.com/colon_nodes_grays.gif. [16] Cunningham, D., W. Atkin, H.-J. Lenz, H.T. Lynch, B. Minsky, B. Nordlinger, et al., Colorectal cancer. The Lancet, 2014. 375(9719): p. 1030-47. [17] Sobin, L.H., M.K. Gospodarowicz and C. Wittekind, TNM Classification of Malignant Tumours: Wiley. 2011. [18] CRUK, Diagram showing T stages of bowel cancer CRUK 276. [Image cited March 2015]; Available from: tinyurl.com/pf2r3v2. [19] About Cancer, Colon Stage. [Image cited April 2015]; Available from: aboutcancer.com/colon_stage.htm. [20] Beart, R.W., G.D. Steele, H.R. Menck, J.S. Chmiel, K.E. Ocwieja and D.P. Winchester, Management and survival of patients with adenocarcinoma of the colon and rectum: a national survey of the Commission on Cancer. Journal of the American College of Surgeons, 1995. 181(3): p. 225-36. [21] Poston, G.J., D. Beauchamp and T. Ruers, Textbook of Surgical Oncology: Taylor & Francis. 2007. [22] CRUK, Cancer Reseach UK's Research Strategy. 2008. p. 48. [23] Emmanuelm, Colon cancer 2. [Image cited 22 April 2014]; Available from: upload.wikimedia.org/wikipedia/commons/c/cc/Colon_cancer_2.jpg. [24] University of Utah, Adenocarcinoma arising in villous adenoma. [Image cited 22 April 2015]; Available from: pathologyoutlines.com/topic/colontumorvillousadenoma.html. [25] Junqueira, L.C.U. and J. Carneiro, Basic Histology: Text & Atlas: McGraw-Hill. 2005. [26] The, C.c.L.o.O.R.S.G., Laparoscopic surgery versus open surgery for colon cancer: short-term outcomes of a randomised trial. The Lancet Oncology, 2005. 6(7): p. 477-84. [27] Harrell, A.G. and B.T. Heniford, Minimally invasive abdominal surgery: lux et veritas past, present, and future. The American Journal of Surgery, 2005. 190(2): p. 239-43. [28] Medicare, D., Laparoscopic sureries. [Image cited 23 November 2014]; Available from: divjoninursinghome.com/laparoscopic_surgery.php. [29] Jacobson, B. and A. Murray, Medical Devices: Use and Safety: Churchill Livingstone. 2007. [30] MD, L., Laparoscopic Trocars. [cited 29/07/15 2015]; Available from: laparoscopic.md/instruments/trocar. [31] Mishra, R.K. and R. Mishra, Textbook of Practical Laparoscopic Surgery: Jaypee Brothers, Medical Publishers Pvt. Limited. 2013. [32] Jamieson, E.S., J.H. Chandler, P.R. Culmer, M. Manogue, M. Mon-Williams and R. Wilkie, Can Virtual Reality Trainers Improve the Compliance Discrimination Abilities of Trainee Surgeons? in Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, 2015: Milan, Italy [33] Remzi, F.H., H.T. Kirat, J.H. Kaouk and D.P. Geisler, Single-port laparoscopy in colorectal surgery. Colorectal Disease, 2008. 10(8): p. 823-6. [34] Wedmid, A., E. Llukani and D.I. Lee, Future perspectives in robotic surgery. BJU International, 2011. 108(6b): p. 1028-36. [35] Faust, R.A., Robotics in Surgery: History, Current and Future Applications: Nova Science Publishers. 2007. [36] Freschi, C., V. Ferrari, F. Melfi, M. Ferrari, F. Mosca and A. Cuschieri, Technical review of the da Vinci surgical telemanipulator. The International Journal of Medical Robotics and Computer Assisted Surgery, 2013. 9(4): p. 396-406. [37] Tholey, G., J.P. Desai and A.E. Castellanos, Force Feedback Plays a Significant Role in Minimally Invasive Surgery: Results and Analysis. Annals of Surgery, 2005. 241(1): p. 102-9. [38] Mayer, H., I. Nagy, A. Knoll, E. Braun, R. Bauernschmitt and R. Lange, Haptic Feedback in a Telepresence System for Endoscopic Heart Surgery. Presence, 2007. 16(5): p. 459-70. [39] Rao, P.P., P.P. Rao and S. Bhagwat, Single-incision laparoscopic surgery - current status and controversies. Journal of Minimal Access Surgery, 2011. 7(1): p. 6-16. [40] Autorino, R., R. Yakoubi, W.M. White, M. Gettman, M. De Sio, C. Quattrone, et al., Natural orifice transluminal endoscopic surgery (NOTES): where are we going? A bibliometric assessment. BJU International, 2013. 111(1): p. 11-6. [41] Nordlinger, C., The Internet of Things and the Operating Room of the Future. 2015. [42] Kopelman, Y., R.J. Lanzafame and D. Kopelman, Trends in Evolving Technologies in the Operating Room of the Future. JSLS : Journal of the Society of Laparoendoscopic Surgeons, 2013. 17(2): p. 171-3. [43] Moustris, G.P., S.C. Hiridis, K.M. Deliparaschos and K.M. Konstantinidis, Evolution of autonomous and semi-autonomous robotic surgical systems: a review of the literature. The International Journal of Medical Robotics and Computer Assisted Surgery, 2011. 7(4): p. 375-92. [44] Balog, J., L. Sasi-Szabó, J. Kinross, M.R. Lewis, L.J. Muirhead, K. Veselkov, et al., Intraoperative Tissue Identification Using Rapid Evaporative Ionization Mass Spectrometry. Science Translational Medicine, 2013. 5(194): p. 194ra93. [45] Fung, Y.C., Biomechanics: Mechanical Properties of Living Tissues: Springer New York. 2013. [46] Hayashi, K. Mechanical Properties of Soft Tissues and Arterial Walls. In: Holzapfel GA, Ogden RW, editors. Biomechanics of Soft Tissue in Cardiovascular Systems: Springer Vienna. 2014. p. 15-54. [47] Hoyt, K., B. Castaneda, M. Zhang, P. Nigwekar, P.A. di Sant'agnese, J.V. Joseph, et al., Tissue elasticity properties as biomarkers for prostate cancer. Cancer Biomark, 2008. 4(4-5): p. 213-25. [48] Krouskop, T.A., T.M. Wheeler, F. Kallel, B.S. Garra and T. Hall, Elastic Moduli of Breast and Prostate Tissues under Compression. Ultrasonic Imaging, 1998. 20(4): p. 260-74. [49] Phipps, S., T.H.J. Yang, F.K. Habib, R.L. Reuben and S.A. McNeill, Measurement of tissue mechanical characteristics to distinguish between benign and malignant prostatic disease. Urology, 2005. 66(2): p. 447-50. [50] Blanks, R.G., S.M. Moss, C.E. McGahan, M.J. Quinn and P.J. Babb, Effect of NHS breast screening programme on mortality from breast cancer in England and Wales, 1990-8: comparison of observed with predicted mortality2000. [51] Barton, M.B., R. Harris and S.W. Fletcher, Does this patient have breast cancer?: The screening clinical breast examination: should it be done? how? JAMA, 1999. 282(13): p. 1270-80. [52] Maxwell, J., White, J.R., David, P, O'Brien, III. Prostate Examination. In: Walker KH, Hall, W.D., Hurst, J.W, editor. Clinical Methods: The History, Physical, and Laboratory Examinations. 3rd ed. Boston: Butterworths. 1990. [53] Lai, W.M., D. Rubin and E. Krempl, Introduction to Continuum Mechanics: Butterworth-Heinemann/Elsevier. 2009. [54] Landau, L.D., L.P. Pitaevskii, A.M. Kosevich and E.M. Lifshitz, Theory of Elasticity: Elsevier Science. 2012. [55] Flügge, W., Viscoelasticity: Springer Berlin Heidelberg. 2013. [56] Mow, V.C. and W.M. Lai, Recent Developments in Synovial Joint Biomechanics. SIAM Review, 1980. 22(3): p. 275-317. [57] Tholey, G., A. Pillarisetti, W. Green and J. Desai. Design, Development, and Testing of an Automated Laparoscopic Grasper with 3-D Force Measurement Capability Medical Simulation. In: Cotin S, Metaxas D, editors.: Springer Berlin / Heidelberg. 2004. p. 38-48. [58] Zbyszewski, D., P. Polygerinos, L.D. Seneviratne and K. Althoefer, A novel MRI compatible air-cushion tactile sensor for Minimally Invasive Surgery. IEEE/RSJ International Conference on Intelligent Robots and Systems, 2009 (IROS) St. Louis, USA2009. p. 2647-52. [59] Zbyszewski, D., B. Challacombe, J. Li, L. Seneviratne, K. Althoefer, P. Dasgupta, et al., A comparative study between an improved novel air-cushion sensor and a wheeled probe for minimally invasive surgery. Journal of endourology / Endourological Society, 2010. 24(7): p. 1155-9. [60] Phipps, S., T.H.J. Yang, F.K. Habib, R.L. Reuben and S.A. McNeill, Measurement of the mechanical characteristics of benign prostatic tissue: A Novel method for assessing benign prostatic disease. Urology, 2005. 65(5): p. 1024-8. [61] Yang, T.H., S. Leung Sk Fau - Phipps, R.L. Phipps S Fau - Reuben, S.A. Reuben Rl Fau - McNeill, F.K. McNeill Sa Fau - Habib, A. Habib Fk Fau - Schnieder, et al., In-vitro dynamic micro-probing and the mechanical properties of human prostate tissues. (0928-7329 (Print)): p. [62] Hein, M., T.H. Yang, R.L. Reuben and E. R.W., Dynamic measurement of intraocular pressure using a mechanical model of the human eye. Medicine Meets Engineering, 2008. 133: p. 112-22. [63] Hien, M.R. and R.L. Reuben. Dynamic palpation device to evaluate IOP; simulation on a mechanical eyeball system. In: Dössel O, Schlegel W, editors. World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany: Springer Berlin Heidelberg. 2009. p. 339-42. [64] Scanlan, P., S.J. Hammer, D.W. Good, S. Phipps, G.D. Stewart, S.A. McNeill, et al., Development of a novel actuator for the dynamic palpation of soft tissue for use in the assessment of prostate tissue quality. Sensors and Actuators A: Physical, (0): p. [65] Kersaudy-Kerhoas, M., F. Amalou, A. Che, J. Kelly, Y. Liu, M.P.Y. Desmulliez, et al., Validation of a fully integrated platform and disposable microfluidic chips enabling parallel purification of genome segments for assembly. Biotechnology and Bioengineering, 2014. 111(8): p. 1627-37. [66] Gunn, C., Digital and Radiographic Imaging: A Practical Approach: Elsevier Health Sciences. 2008. [67] Szabo, T.L., Diagnostic Ultrasound Imaging: Inside Out: Elsevier Academic Press. 2004. [68] Taylor, L.S., B.C. Porter, D.J. Rubens and K.J. Parker, Three-dimensional sonoelastography: principles and practices. Physics in Medicine and Biology, 2000. 45(6): p. 1477-94. [69] Parker, K.J., M.M. Doyley and D.J. Rubens, Imaging the elastic properties of tissue: the 20 year perspective Physics in Medicine and Biology, 2011. 56: p. R1-R29. [70] Krouskop, T.A., D.R. Dougherty and F.S. Vinson, A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue. Journal of rehabilitation research and development, 1987. 24(2): p. 1-8. [71] Lerner, R.M., S.R. Huang and K.J. Parker, “Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissues. Ultrasound in Medicine & Biology, 1990. 16(3): p. 231-9. [72] Parker, K.J., S.R. Huang, R.A. Musulin and R.M. Lerner, Tissue response to mechanical vibrations for “sonoelasticity imaging”. Ultrasound in Medicine & Biology, 1990. 16(3): p. 241-6. [73] Ophir, J., I. Céspedes, H. Ponnekanti, Y. Yazdi and X. Li, Elastography: A quantitative method for imaging the elasticity of biological tissues. Ultrasonic Imaging, 1991. 13(2): p. 111-34. [74] Garra, B.S., E.I. Cespedes, J. Ophir, S.R. Spratt, R.A. Zuurbier, C.M. Magnant, et al., Elastography of breast lesions: initial clinical results. Radiology, 1997. 202(1): p. 79-86. [75] de Korte, C.L., E.I. Cespedes, A.F.W. van der Steen, G. Pasterkamp and N. Bom, Intravascular ultrasound elastography: assessment and imaging of elastic properties of diseased arteries and vulnerable plaque. European Journal of Ultrasound, 1998. 7(3): p. 219-24. [76] Ophir, J., S.K. Alam, B. Garra, F. Kallel, E. Konofagou, T. Krouskop, et al., Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1999. 213(3): p. 203-33. [77] Lindop, J.E., 2D and 3D Elastic Imaging Using Freehand Ultrasound. Pembroke College: Univerity of Cambridge; 2008. [78] Tanter, M., J. Bercoff, A. Athanasiou, T. Deffieux, J.-L. Gennisson, G. Montaldo, et al., Quantitative Assessment of Breast Lesion Viscoelasticity: Initial Clinical Results Using Supersonic Shear Imaging. Ultrasound in Medicine & Biology, 2008. 34(9): p. 1373-86. [79] Hoyt, K., K.J. Parker and D.J. Rubens, Real-Time Shear Velocity Imaging Using Sonoelastographic Techniques. Ultrasound in Medicine & Biology, 2007. 33(7): p. 1086-97. [80] Bhatia, K.S.S., C.C.M. Cho, Y.-H. Yuen, D.D. Rasalkar, A.D. King and A.T. Ahuja, Real-Time Qualitative Ultrasound Elastography of Cervical Lymph Nodes in Routine Clinical Practice: Interobserver Agreement and Correlation with Malignancy. Ultrasound in Medicine & Biology, 2010. 36(12): p. 1990-7. [81] Yoneda, M., K. Suzuki, S. Kato, K. Fujita, Y. Nozaki, K. Hosono, et al., Nonalcoholic Fatty Liver Disease: US-based Acoustic Radiation Force Impulse Elastography 1. Radiology, 2010. p. [82] Miklavčič, D., N. Pavšelj and F.X. Hart. Electric Properties of Tissues. Wiley Encyclopedia of Biomedical Engineering: John Wiley & Sons, Inc. 2006. [83] Gileadi, E., Physical Electrochemistry: Wiley. 2011. [84] Bard, A.J. and L.R. Faulkner, Electrochemical Methods: Fundamentals and Applications. New York: Wiley. 1980. [85] Schauble, M.K., H.D. Gullick and M.B. Habal, Variations in tissue electropotentials and their possible significance. Journal of Surgical Research, 1972. 12(5): p. 325-9. [86] Schauble, M.K. and M.B. Habal, Electropotentials of normal tissue. Journal of Surgical Research, 1969. 9(9): p. 513-5. [87] Gensler, W., Tissue Electropotentials in Kalanchoë blossfeldiana During Wound Healing. American Journal of Botany, 1978. 65(2): p. 152-7. [88] Burr, H.S., G.M. Smith and L.C. Strong, Bio-Electric Properties of Cancer-Resistant and Cancer-Susceptible Mice. The American Journal of Cancer, 1938. 32(2): p. 240-8. [89] Morris, D.M. Detection of Surface Electropotentials of Human Breast Lesions. In: Saha S, editor. Biomedical Engineering: I Recent Developments: Proceedings of the First Southern Biomedical Engineering Conference: Elsevier Science. 2013. p. 125-9. [90] Miklavcic, D., G. Sersa, S. Novaković and S. Rebersek, Tumor Bioelectric Potential and its Possible Exploitation for Tumor Growth Retardation. Electromagnetic Biology and Medicine, 1990. 9(2): p. 133-49. [91] Michaelis, L. and W. Davidoff, Methodisches und Sachliches zur elektrometrischen Bestimmung der Blutalkalescenz. . Zschr., 46:131. Biochem, 1912. 46: p. 131-50. [92] Michaelis, L. and A. Kramsztyk, Die Wasserstoffionenkonzentration der Gewebssafte. Biochem, 1914. 62: p. 180-5. [93] Buerk, D.G., Biosensors: Theory and Applications: Taylor & Francis. 1995. [94] Turner, A., I. Karube and G.S. Wilson, Biosensors: fundamentals and applications. 1987. p. [95] Shukla, P., Biosensors. 2014. [96] DropSens, Screen printed electrodes. [Image cited Available from: dropsens.com/en/screen_printed_electrodes_pag.html#modified_carbon_spes. [97] Chen, C., Q. Xie, D. Yang, H. Xiao, Y. Fu, Y. Tan, et al., Recent advances in electrochemical glucose biosensors: a review. RSC Advances, 2013. 3(14): p. 4473-91. [98] Li, J., S. Li and C.F. Yang, Electrochemical Biosensors for Cancer Biomarker Detection. Electroanalysis, 2012. 24(12): p. 2213-29. [99] Biomarkers Definitions Working, G., Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework. Clinical Pharmacology & Therapeutics, 2001. 69(3): p. 89-95. [100] Brenner, D.E. and D.P. Normolle, Biomarkers for Cancer Risk, Early Detection, and Prognosis: The Validation Conundrum. Cancer Epidemiology Biomarkers & Prevention, 2007. 16(10): p. 1918-20. [101] Vaupel, P., F. Kallinowski and P. Okunieff, Blood Flow, Oxygen and Nutrient Supply, and Metabolic Microenvironment of Human Tumors: A Review. Cancer Research, 1989. 49(23): p. 6449-65. [102] Kieninger, J., A. Dannenberg, K. Aravindalochanan, G. Jobst, E.O. Pettersen and G.A. Urban, Amperometric Oxygen Sensor Array with Novel Chronoamperometric Protocols for Hypoxic Tumor Cell Cultures. Solid-State Sensors, Actuators and Microsystems Conference, 2007 Transducers 2007 International2007. p. 1907-10. [103] Kotanen, C.N., F.G. Moussy, S. Carrara and A. Guiseppi-Elie, Implantable enzyme amperometric biosensors. Biosensors and Bioelectronics, 2012. 35(1): p. 14-26. [104] Grimnes, S. and O.G. Martinsen, Bioimpedance and Bioelectricity Basics: Academic Press. 2008. [105] Chen, J.H. and S.A. Adelman, Macroscopic model for solvated ion dynamics. The Journal of Chemical Physics, 1980. 72(4): p. 2819-31. [106] Nakahara, M. and K. Ibuki, Is the Walden product useful? The Journal of Physical Chemistry, 1986. 90(13): p. 3026-30. [107] Zwanzig, R., Dielectric Friction on a Moving Ion. II. Revised Theory. The Journal of Chemical Physics, 1970. 52(7): p. 3625-8. [108] Martinsen, O.G. and S. Grimnes, Bioimpedance and Bioelectricity Basics: Academic Press. 2000. [109] Burger, H.C. and R.v. Dongen, Specific Electric Resistance of Body Tissues. Physics in Medicine and Biology, 1961. 5(4): p. 431. [110] Kalvøy, H., G.K. Johnsen, O.G. Martinsen and S. Grimnes, New method for separation of electrode polarization impedance from measured tissue impedance. Open Biomed Eng J, 2011. 5: p. 6. [111] Faes, T.J., H.A. van der Meij, J.C. de Munck and R.M. Heethaar, The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. Physiological measurement, 1999. 20(4): p. R1-10. [112] Zanello, P. and R.S.o. Chemistry, Inorganic Electrochemistry: Theory, Practice and Applications: Royal Society of Chemistry. 2003. [113] Galvani, L., R.M. Green and G. Aldini, De Viribus Electricitatis in Motu Musculari Commentarius: A Translation of Luigi Galvani's de Viribus Electricitatisin Motu Musculari Commentarius: Licht. 1953. [114] Rao, J.R. and G. Richter, Implantable bio-electrochemical power sources. Naturwissenschaften, 1974. 61(5): p. 200-6. [115] Golberg, A., H.D. Rabinowitch and B. Rubinsky, Galvanic apparent internal impedance: An intrinsic tissue property. Biochemical and Biophysical Research Communications, 2009. 389(1): p. 168-71. [116] Golberg, A., S. Laufer, H.D. Rabinowitch and B. Rubinsky, In vivo non-thermal irreversible electroporation impact on rat liver galvanic apparent internal resistance. Physics in Medicine and Biology, 2011. 56(4): p. 951-63. [117] Golberg, A., S. Laufer, H.D. Rabinowitch and B. Rubinsky, In vivo non-thermal irreversible electroporation impact on rat liver galvanic apparent internal resistance. Physics in Medicine and Biology, 2011. 56(4): p. 951-63. [118] Spottorno, J., M. Multigner, G. Rivero, L. Álvarez, J.d.l. Venta and M. Santos, Time dependence of electrical bioimpedance on porcine liver and kidney under a 50 Hz ac current. Physics in Medicine and Biology, 2008. 53(6): p. 1701. [119] Technologies, A., Agilent Impedance Measurement Handbook. A guide to measurement technology and techniques. 4th ed. literature.agilent.com2014. [120] Schwan, H.P., Electric Characteristics of Tissues. Radiation and Environmental Biophysics, 1963. 1(3): p. 198-208. [121] Gabriel, C., S. Gabriel and E. Corthout, The dielectric properties of biological tissues: I. Literature survey. Physics in Medicine and Biology, 1996. 41(11): p. 2231. [122] Gabriel, S., R.W. Lau and C. Gabriel, The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Physics in Medicine and Biology, 1996b. 41(11): p. 2251. [123] Laufer, S., A. Ivorra, V.E. Reuter, B. Rubinsky and S.B. Solomon, Electrical impedance characterization of normal and cancerous human hepatic tissue. Physiological measurement, 2010. 31: p. 995-1009. [124] Chauveau, N., L. Hamzaoui, P. Rochaix, B. Rigaud, J.J. Voigt and J.P. Morucci, Ex vivo discrimination between normal and pathological tissues in human breast surgical biopsies using bioimpedance spectroscopy. Annals of the New York Academy of Sciences, 1999. 873: p. 42-50. [125] Jossinet, J., The impedivity of freshly excised human breast tissue. Physiological measurement, 1998. 19(1): p. 61. [126] Åberg, P., I. Nicander, U. Holmgren, P. Geladi and S. Ollmar, Assessment of skin lesions and skin cancer using simple electrical impedance indices. Skin Research and Technology, 2003. 9(3): p. 257-61. [127] Aberg, P., P. Geladi, I. Nicander, J. Hansson, U. Holmgren and S. Ollmar, Non-invasive and microinvasive electrical impedance spectra of skin cancer - a comparison between two techniques. Skin Research and Technology, 2005. 11(4): p. 281-6. [128] Dua, R., D.G. Beetner, W.V. Stoecker and D.C. Wunsch, II, Detection of basal cell carcinoma using electrical impedance and neural networks. Biomedical Engineering, IEEE Transactions on, 2004. 51(1): p. 66-71. [129] B. Blad, P.W., M. Jonsson, K. Lindstrom, An electrical impedance index to distinguish between normal and cancerous tissues. Journal of Medical Engineering & Technology, 1999. 23(2): p. 57-62. [130] Mongra, A.C., Commercial Biosensors: An outlook. Journal of Academic and Industrial Research, 2012. 1(6): p. 3. [131] TearLab, TearLab. [cited January 2015]; Available from: tearlab.com. [132] Zeev, M.S.-B., D.D. Miller and R. Latkany, Diagnosis of dry eye disease and emerging technologies. Clinical Ophthalmology (Auckland, NZ), 2014. 8: p. 581-90. [133] Zilico, What is ZedScan. [cited August 2015]; Available from: zilico.co.uk/zedscan/zedscan. [134] Brown, B.H., R.H. Smallwood, K.J. Boston, A.D. Blackett and J.A. Tidy, Electrical impedance measuring method for differentiating tissue types. In: Organization WIP, editor. G01N 33/487, 33/483, A61B 5/05 ed2001. [135] Abdul, S., B.H. Brown, P. Milnes and J.A. Tidy, The use of electrical impedance spectroscopy in the detection of cervical intraepithelial neoplasia. International Journal of Gynecological Cancer, 2006. 16(5): p. 1823-32. [136] Taruttis, A. and V. Ntziachristos, Translational Optical Imaging. American Journal of Roentgenology, 2012. 199(2): p. 263-71. [137] Bu, L., B. Shen and Z. Cheng, Fluorescent imaging of cancerous tissues for targeted surgery. Advanced Drug Delivery Reviews, 2014. 76: p. 21-38. [138] Sajja, H.K., M.P. East, H. Mao, Y.A. Wang, S. Nie and L. Yang, Development of multifunctional nanoparticles for targeted drug delivery and noninvasive imaging of therapeutic effect. Curr Drug Discov Technol, 2009. 6(1): p. 43-51. [139] Alander, J.T., I. Kaartinen, A. Laakso, T. P, #228, til, et al., A review of indocyanine green fluorescent imaging in surgery. Journal of Biomedical Imaging, 2012. 2012: p. 7-. [140] Recendt, Principle of photoacoustic imaging. [Image cited March 2015]; Available from: recendt.at/528_ENG_HTML.php. [141] Schaafsma, B.E., J.S.D. Mieog, M. Hutteman, J.R. van der Vorst, P.J.K. Kuppen, C.W.G.M. Löwik, et al., The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery. Journal of Surgical Oncology, 2011. 104(3): p. 323-32. [142] Kondo, Y., Y. Murayama, H. Konishi, R. Morimura, S. Komatsu, A. Shiozaki, et al., Fluorescent detection of peritoneal metastasis in human colorectal cancer using 5-aminolevulinic acid. International Journal of Oncology, 2014. p. [143] Filonenko, E.V., A.D. Kaprin, A.A. Raszhivina, A.N. Urlova and A.M. Nechipai, Fluorescence Diagnostics of Colon Malignant and Premalignant Lesions Using 5-Aminolevulinic Acid. International Journal of Photoenergy, 2014. 2014: p. 4. [144] Mehrmohammadi, M., S.J. Yoon, D. Yeager and S.Y. Emelianov, Photoacoustic Imaging for Cancer Detection and Staging. Current molecular imaging, 2013. 2(1): p. 89-105. [145] Zackrisson, S., S.M.W.Y. van de Ven and S.S. Gambhir, Light In and Sound Out: Emerging Translational Strategies for Photoacoustic Imaging. Cancer Research, 2014. 74(4): p. 979-1004. [146] Palmeri, M.L. and N.K. R.. What challenges must be overcome before ultrasound elasticity imaging is ready for the clinic? Imaging Med, 2011. 3(4): p. 11. [147] Curiel, L., R. Souchon, O. Rouvière, A. Gelet and J.Y. Chapelon, Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: Initial comparison with MRI. Ultrasound in Medicine & Biology, 2005. 31(11): p. 1461-8. [148] Clark, L.C., Monitor and control of blood and tissue oxygen tensions. Transactions of the American society for Articial Internal Organs 1956. 2: p. 8. [149] Golberg, A., H.D. Rabinowitch and B. Rubinsky, Zn/Cu- vegetative batteries, bioelectrical characterizations and primary cost analyses. J. Renewable and Sustainable Energy. Journal of Renewable and Sustainable Energy, 2010. 2(3): p. 11. [150] Li, G. and P. Miao. Theoretical Background of Electrochemical Analysis. Electrochemical Analysis of Proteins and Cells: Springer Berlin Heidelberg. 2013. p. 5-18. [151] Instruments, N., Specifications NI myDAQ. 2014. [152] Metrohm, Basic overview of the working principle of a potentiostat/galvanostat (PGSTAT) - Electrochemical cell setup. Autolab Application Note EC08. 2016. [153] Technologies, I., CompactStat: Hardware specifications. [cited Available from: ivium.nl/CompactStat%20Hardware%20specifications. [154] Schwarzenbach, J., Essentials of Control: Longman. 1996. [155] Moré, J. The Levenberg-Marquardt algorithm: Implementation and theory. In: Watson GA, editor. Numerical Analysis. New York: Springer-Verlag. 1977. p. 105-16. [156] Chandler, J.H., A. Hood, P.R. Culmer, D. Jayne and A. Neville, Technological assessment of the biogalvanic method for tissue characterization. Physiological Measurement, 2014. 35(2): p. 297. [157] Lal, H. and H.R. Thirsk, The anodic behaviour of copper in neutral and alkaline chloride solutions. J Chem Soc, 1953. (0): p. 2638-44. [158] Miklavčič, D., N. Pavšelj and F.X. Hart. Electric Properties of Tissues. In: Akay M, editor. Wiley Encyclopedia of Biomedical Engineering. New York: John Wiley & Sons, Inc. 2006. p. 3578-89. [159] Bard, A.J. and L.R. Faulkner, Electrochemical Methods: Fundamentals and Applications 2nd ed. 2nd ed. New York: Wiley. 2001. [160] Thomas, S., N. Birbilis, M.S. Venkatraman and I.S. Cole, Corrosion of Zinc as a Function of pH. Corrosion, 2012. 68(1): p. 015009-1--9. [161] García-Antón, J., A. Igual-Muñoz, J.L. Guiñón, V. Pérez-Herranz and J. Pertusa-Grau, Online Visualization of Corrosion Processes of Zinc and a Cu/Zn Galvanic Pair in Lithium Bromide Solutions. Corrosion, 2003. 59(2): p. 172-80. [162] Kear, G.A., C. Ponce de Leon Albarran and F.C. Walsh, Reduction of dissolved oxygen at a copper rotating disc electrode. Chemical Engineering Education, 2005. 39: p. 14-21. [163] Igual-Muñoz, A., J. García-Antón, J.L. Guiñón and V. Pérez-Herranz, Galvanic Study of Zinc and Copper in Lithium Bromide Solutions at Different Temperatures. Corrosion, 2001. 57(6): p. 516-22. [164] Grimnes, S. and O.G. Martinsen, Bioimpedance and Bioelectricity Basics. New York: Academic Press. 2000. [165] Halter, R.J., A. Hartov, K.D. Paulsen, A. Schned and J. Heaney, Genetic and least squares algorithms for estimating spectral EIS parameters of prostatic tissues. Physiol Meas, 2008. 29(6): p. S111-S23. [166] Gilányi, M., C. Ikrényi, J. Fekete, K. Ikrényi and A.G. Kovách, Ion concentrations in subcutaneous interstitial fluid: measured versus expected values. Am J Physiol, 1988. 255(3 Pt 2): p. 513-9. [167] de Silva, C.W., Mechatronics: An Integrated Approach: Taylor & Francis. 2004. [168] Carreau, A., B.E. Hafny-Rahbi, A. Matejuk, C. Grillon and C. Kieda, Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia. J Cell Mol Med, 2011. 15(6): p. 1239-53. [169] Sherwood, J.E., F. Stagnitti, M.J. Kokkinn and W.D. Williams, A standard table for predicting equilibrium dissolved oxygen concentrations in Salt Lakes dominated by sodium chloride. Int J Salt Lake Res, 1992. 1(1): p. 1-6. [170] Parthasarathy, A., S. Srinivasan, A.J. Appleby and C.R. Martin, Temperature Dependence of the Electrode Kinetics of Oxygen Reduction at the Platinum/Nafion® Interface—A Microelectrode Investigation. Journal of The Electrochemical Society, 1992. 139(9): p. 2530-7. [171] Vukmirovic, M.B., N. Vasiljevic, N. Dimitrov and K. Sieradzki, Diffusion-Limited Current Density of Oxygen Reduction on Copper. Journal of The Electrochemical Society, 2003. 150(1): p. B10-B5. [172] Tobias, C.W., M. Eisenberg and C.R. Wilke, Fiftieth Anniversary: Diffusion and Convection in Electrolysis—A Theoretical Review. Journal of The Electrochemical Society, 1952. 99(12): p. 359C-65C. [173] Chandler, J.H., P.R. Culmer, D.G. Jayne and A. Neville, Assessment of electrochemical properties of a biogalvanic system for tissue characterisation. Bioelectrochemistry, 2015. 101: p. 138-45. [174] Moisel, M., M.A.F.L. de Mele and W.D. Müller, Biomaterial Interface Investigated by Electrochemical Impedance Spectroscopy. Advanced Engineering Materials, 2008. 10(10): p. B33-B46. [175] Walter, G.W., Critical analysis of some electrochemical techniques including polarization resistance, for the study of zinc coating performance in near neutral chloride solutions. Corrosion Science, 1975. 15(1): p. 47-56. [176] Chandler, J.H., P.R. Culmer, D.G. Jayne and A. Neville, Assessment of electrochemical properties of a biogalvanic system for tissue characterisation. Bioelectrochemistry, 2015. 101(0): p. 138-45. [177] Press, W.H., Numerical Recipes 3rd Edition: The Art of Scientific Computing: Cambridge University Press. 2007. [178] Doig, P. and P.E.J. Flewitt, A Finite Difference Numerical Analysis of Galvanic Corrosion for Semi‐Infinite Linear Coplanar Electrodes. Journal of The Electrochemical Society, 1979. 126(12): p. 2057-63. [179] Munn, R.S. and O.F. Devereux, Numerical Modeling and Solution of Galvanic Corrosion Systems: Part I. Governing Differential Equation and Electrodic Boundary Conditions. Corrosion, 1991. 47(8): p. 612-8. [180] Saad, Y. and M.H. Schultz, GMRES: a generalized minimal residual algorithm for solving nonsymmetric linear systems. SIAM J Sci Stat Comput, 1986. 7(3): p. 856-69. [181] Hamann, C.H., A. Hamnett and W. Vielstich, Electrochemistry: Wiley. 2007. [182] Faes, T.J.C., H.A.v.d. Meij, J.C.d. Munck and R.M. Heethaar, The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. Physiol Meas, 1999. 20(4): p. R1. [183] Faes, T.J., H.A. van der Meij, J.C. de Munck and R.M. Heethaar, The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. Physiol Meas, 1999. 20(4): p. R1-10. [184] Wang, J., Electrochemical glucose biosensors. Chemical reviews, 2008. 108(2): p. 814-25. [185] Soper, S.A., K. Brown, A. Ellington, B. Frazier, G. Garcia-Manero, V. Gau, et al., Point-of-care biosensor systems for cancer diagnostics/prognostics. Biosensors and Bioelectronics, 2006. 21(10): p. 1932-42. [186] Brown, B.H., J.A. Tidy, K. Boston, A.D. Blackett, R.H. Smallwood and F. Sharp, Relation between tissue structure and imposed electrical current flow in cervical neoplasia. The Lancet, 2000. 355(9207): p. 892-5. [187] Tidy, J.A., B.H. Brown, T.J. Healey, S. Daayana, M. Martin, W. Prendiville, et al., Accuracy of detection of high-grade cervical intraepithelial neoplasia using electrical impedance spectroscopy with colposcopy. BJOG: An International Journal of Obstetrics & Gynaecology, 2013. 120(4): p. 400-11. [188] Scribner, L.L. and S.R. Taylor, The Measurement and Correction of Electrolyte Resistance in Electrochemical Tests. Baltimore: ASTM. 1990. [189] Hack, H.P., P.J. Moran and J.R. Scully. Influence of Electrolyte Resistance on Electrochemical Measurements and Proceedures to Minimize or Compensate for Resistance Errors. In: 1056 AS, Scribner LL, Taylor SR, editors. The Measurement and Correction of Electrolyte Resistance in Electrochemical Tests. Philadelphia: American Society for Testing and Materials. 1990. p. 5-26. [190] Britz, D., iR elimination in electrochemical cells. Journal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1978. 88(3): p. 309-52. [191] Barnartt, S., Primary Current Distribution Around Capillary Tips Used in the Measurement of Electrolytic Polarization. Journal of The Electrochemical Society, 1952. 99(12): p. 549-53. [192] Barnartt, S., Magnitude of IR‐Drop Corrections in Electrode Polarization Measurements Made with a Luggin‐Haber Capillary. Journal of The Electrochemical Society, 1961. 108(1): p. 102-4. [193] Hong, S.H., C. Kraiya, M.W. Lehmann and D.H. Evans, Evaluation of uncompensated solution resistance for electrodes with spherical-cap geometry. Anal Chem, 2000. 72(3): p. 454-8. [194] McIntyre, J.D.E. and W.F. Peck, An Interrupter Technique for Measuring the Uncompensated Resistance of Electrode Reactions under Potentiostatic Control. Journal of The Electrochemical Society, 1970. 117(6): p. 747-51. [195] Williams, L.F.G. and R.J. Taylor, iR correction: Part I. A computerised interrupt method. Journal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1980. 108(3): p. 293-303. [196] Herrmann, C.C., G.G. Perrault and A.A. Pilla, Dual reference electrode for electrochemical pulse studies. Analytical Chemistry, 1968. 40(7): p. 1173-4. [197] Pallás-Areny, R. and J.G. Webster. Signal Conditioning for Resistive Sensors. Sensors and Signal Conditioning, Second Edition: John Wiley & Sons, Limited. 2006. p. 133-206. [198] Jha, C. and A. Sanchez. Microprocessor Temperature Sensing and Thermal Management. Thermal Sensors: Principles and Applications for Semiconductor Industries: Springer New York. 2015. [199] Haglund, W.D. and M.H. Sorg. Postmortem changes in soft tissues. Forensic Taphonomy: The Postmortem Fate of Human Remains: Taylor & Francis. 1996. p. 151-64. [200] Haemmerich, D., O.R. Ozkan, J.Z. Tsai, S.T. Staelin, S. Tungjitkusolmun, D.M. Mahvi, et al., Changes in electrical resistivity of swine liver after occlusion and postmortem. Medical and Biological Engineering and Computing, 2002. 40(1): p. 29-33. [201] Mortimer, J.T., D. Kaufman and U. Roessmann, Intramuscular electrical stimulation: Tissue damage. Annals of Biomedical Engineering, 1980. 8(3): p. 235-44. [202] Chandler, J.H., A. Hood, P.R. Culmer, D. Jayne and A. Neville, A bio-galvanic approach to tissue characterisation: technological considerations. in Hamlyn Symposium on Medical Robotics, 2013: London, UK [203] Chandler, J.H., D.G. Jayne, A. Neville and P.R. Culmer, A novel multiple electrode direct current technique for characterisation of tissue resistance during surgery. in Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, 2015: Milan, Italy [204] Chandler, J.H., P.R. Culmer, D.G. Jayne and A. Neville, A time-dependent model for improved biogalvanic tissue characterisation. Medical Engineering & Physics: p. [205] Rutherford, D.E., Vector Methods Applied to Differential Geometry, Mechanics, and Potential Theory: Dover Publications. 2004."],"dcterms:accessrights":["public"],"dc:title":["Direct current electrical resistance measurement techniques for assessment of colorectal cancer during laparoscopic surgery"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T21:40:56Z"}