{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:13344"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:13344","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Determination of the Transverse Horizontal Axis and Interocclusal Registration Using a Novel Optical Technique","abstract":"Motivation: Dental treatments sometimes require the recording and reproduction of the patient’s transverse horizontal axis (THA). This is the axis about which the mandible will rotate, when the condyles are fully seated in their glenoid fossae. However, methods for recording this axis are rarely used in general practice, due to expense and perceived lack of efficacy. Problem Statement: A simplified method for accurately recording the THA, and interocclusal records (IORs), is needed for general dentistry. Approach: An optical 3D scanning method is proposed to kinematically record the THA. A simulation determines the required hardware specifications to build the scanner at minimal cost. The ability to record the hinge axis of a dental articulator is explored. High quality interocclusal optical records are essential, and these are investigated in subsequent experiments. Areas for improvements are identified and efforts are made to enhance the system speed and calibration. Results: Simulation results indicated that all 6 upper and lower anterior teeth, including 2mm of gingivae should be captured, with an accuracy of 50µm. The THA on a dental articulator could be located with a radial accuracy of 2.65±1.01mm. The repeatability (precision) of IORs showed a standard deviation of 22µm anteriorly, and a mean of 43µm posteriorly in vitro. The accuracy (trueness and precision) of the IORs was -15±22µm anteriorly, and up to -93±121µm posteriorly in vitro. A faster scanning protocol enabled in vivo testing. 29 IORs of a single subject took <2s to perform. The registrations showed a repeatability of 31µm anteriorly and 70µm posteriorly. A novel calibration process produced significantly reduced stereo reprojection errors compared to traditional methods (0.22 vs 0.27 pixels), offering a potential future system enhancement. Conclusions: The proposed method shows potential to improve the speed, accuracy and simplicity with which the THA, and interocclusal registration, can be recorded. Further developments have been suggested prior to embarking on clinical trials.","abstract_html":"Motivation: Dental treatments sometimes require the recording and reproduction of the patient’s transverse horizontal axis (THA). This is the axis about which the mandible will rotate, when the condyles are fully seated in their glenoid fossae. However, methods for recording this axis are rarely used in general practice, due to expense and perceived lack of efficacy. Problem Statement: A simplified method for accurately recording the THA, and interocclusal records (IORs), is needed for general dentistry. Approach: An optical 3D scanning method is proposed to kinematically record the THA. A simulation determines the required hardware specifications to build the scanner at minimal cost. The ability to record the hinge axis of a dental articulator is explored. High quality interocclusal optical records are essential, and these are investigated in subsequent experiments. Areas for improvements are identified and efforts are made to enhance the system speed and calibration. Results: Simulation results indicated that all 6 upper and lower anterior teeth, including 2mm of gingivae should be captured, with an accuracy of 50µm. The THA on a dental articulator could be located with a radial accuracy of 2.65±1.01mm. The repeatability (precision) of IORs showed a standard deviation of 22µm anteriorly, and a mean of 43µm posteriorly in vitro. The accuracy (trueness and precision) of the IORs was -15±22µm anteriorly, and up to -93±121µm posteriorly in vitro. A faster scanning protocol enabled in vivo testing. 29 IORs of a single subject took &lt;2s to perform. The registrations showed a repeatability of 31µm anteriorly and 70µm posteriorly. A novel calibration process produced significantly reduced stereo reprojection errors compared to traditional methods (0.22 vs 0.27 pixels), offering a potential future system enhancement. Conclusions: The proposed method shows potential to improve the speed, accuracy and simplicity with which the THA, and interocclusal registration, can be recorded. Further developments have been suggested prior to embarking on clinical trials.","abstract_has_math":false,"creators":["Keeling, Andrew James"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Wood, David","Brunton, Paul","Holt, Raymond","Franklin, Paul"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-02","date_published":"2016-02","updated_at":"2026-11-18T21:42:00Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.687241"],"render_values":[{"text":"uk.bl.ethos.687241","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/13344/1/Keeling_AJ_Dentistry_PhD_2016.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A13344","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wood, David","Brunton, Paul","Holt, Raymond","Franklin, Paul"]},{"key":"dc:creator","label":"Author","values":["Keeling, Andrew James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-02"]},{"key":"dc:date.issued","label":"Date","values":["2016-02"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Restorative Dentistry (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/13344/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Academy of Denture Prosthetics, 2005. The glossary of prosthodontic terms. Journal of Prosthetic Dentistry, 94(1), pp.10–92. Adrien, P. & Schouver, J., 1997. Methods for minimizing the errors in mandibular model mounting on an articulator. Journal of Oral Rehabilitation, 24, pp.929–935. Aissaoui, A. et al., 2012. Fast stereo matching method based on optimized correlation algorithm for face depth estimation. In Proceedings of the International Conference on Computer Vision Theory and Applications (VISIGRAPP 2012). pp. 377–380. Bader, J.D., Martin, J.A. & Shugars, D.A., 2001. Incidence rates for complete cusp fracture. Community Dentistry and Oral Epidemiology, 29(5), pp.346–53. Balch, J.H., 2012. Verification of the accuracy of electronic mandibular movement recording devices: an in vitro investigation. Masters thesis, The University of Tennessee Health Science Center, USA. Balkwill, F.H., 1866. On the best form and arrangement of artificial teeth for mastication. Transactions of Great Britain Odontological Society, 5, p.133. Beard, C.C. & Clayton, J.A., 1981. Studies on the validity of the terminal hinge axis. Journal of Prosthetic Dentistry, 46(2), pp.185–191. Bennett, N., 1908. A contribution to the study of the movements of the mandible. Proceedings of the Royal Society of Medicine, Section of Odontology, April 27, pp.79–95. Bergstra, J. et al., 2010. Theano: a CPU and GPU math expression compiler. In Proceedings of the Python for Scientific Computing Conference (SciPy). Austin, TX, pp. 1–7. Bergstrom, G., 1950. On the reproduction of dental articulation by means of articulators. Acta Odontologica Scandinavica. Supplementum, 9(Suppl. 4), pp.3–149. Besl, P. & McKay, N., 1992. A method for registration of 3-D shapes. IEEE Transactions on Pattern Analysis and Machine Intelligence, 14(2), pp.239–256. De Boever, J.A., Carlsson, G.E. & Klineberg, I.J., 2000. Need for occlusal therapy and prosthodontic treatment in the management of temporomandibular disorders. Part II: tooth loss and prosthodontic treatment. Journal of Oral Rehabilitation, 27(8), pp.647–659. Bonwill, W.G.A., 1864. Articulation and articulators. Transactions of the American Dental Association, 26, pp.76–79. Bonwill, W.G.A., 1885. Geometrical and mechanical laws of articulation. Transactions of Pennsylvania Odontological Society, p.119. Bonwill, W.G.A., 1896. What has dentistry to demonstrate against the hypothesis of organic evolution ? In Transactions of the Worlds Columbian Dental Congress. Chicago, pp. 226–240. Brusco, N. et al., 2007. Metrological validation for 3D modeling of dental plaster casts. Medical Engineering & Physics, 29(9), pp.954–66. Campos, A.A., Nathanson, D. & Rose, L., 1996. Reproducibility and condylar position of a physiologic maxillomandibular centric relation in upright and supine body position. Journal of Orthodontics, 76(3), pp.282–287. Carlsson, G.E., 2010. Some dogmas related to prosthodontics, temporomandibular disorders and occlusion. Acta Odontologica Scandinavica, 68(6), pp.313–322. Celenza, F. V, 1973. The centric position: replacement and character. Journal of Prosthetic Dentistry, 30(4), pp.591–598. Chasles, M., 1830. Note sur les proprietes generales du systeme de deux corps semblables entr’eux. Bulletin de Sciences Mathematiques, Astronomiques Physiques et Chimiques, Baron de Ferussac, Paris, pp.321–326. Chen, D.C. et al., 2000. Contributing factors of mandibular deformation during mouth opening. Journal of Dentistry, 28(8), pp.583–588. Chen, X., 1998. The instantaneous center of rotation during human jaw opening and its significance in interpreting the functional meaning of condylar translation. American Journal of Physical Anthropology, 106(1), pp.35–46. Choi, D.G. et al., 1999. Reliability of an ear-bow arbitrary face-bow transfer instrument. Journal of Prosthetic Dentistry, 82(2), pp.150–156. Cioffi, I. et al., 2015. Short-term sensorimotor effects of experimental occlusal interferences on the wake-time masseter muscle activity of females with masticatory muscle pain. Journal of Oral & Facial Pain and Headache, 29(4), pp.331–339. Clark, D.M., Oyen, O.J. & Feil, P., 2001. The use of specific dental school-taught restorative techniques by practicing clinicians. Journal of Dental Education, 65(8), pp.760–5. Clark, J.R. & Evans, R.D., 2001. Functional occlusion: I. A review. Journal of Orthodontics, 28(1), pp.76–81. Davies, S. & Gray, R.M., 2001. What is occlusion? British Dental Journal, 191(5), pp.235–238, 241–245. Davies, S.J., Gray, R.M. & Smith, P.W., 2001. Good occlusal practice in simple restorative dentistry. British Dental Journal, 191(7), pp.365–381. Dawson, P., 1989. Evaluation, diagnosis and treatment of occlusal problems. 2nd ed., St Louis: Elsevier. DeLong, R. et al., 2007. Accuracy of contacts calculated from 3D images of occlusal surfaces. Journal of Dentistry, 35(6), pp.528–534. Delong, R. et al., 2002. Comparing maximum intercuspal contacts of virtual dental patients and mounted dental casts. Journal of Prosthetic Dentistry, 88(6), pp.622–630. DeLong, R. et al., 2002. Helical axis errors affect computer-generated occlusal contacts. Journal of Dental Research, 81(5), pp.338–343. Donovan, T.E. & Chee, W.W.L., 2004. A review of contemporary impression materials and techniques. Dental Clinics of North America, 48, pp.445–70. Ender, A., Attin, T. & Mehl, A., 2016. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. Journal of Prosthetic Dentistry, 115(3), pp.313–320. Ender, A. & Mehl, A., 2013. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. Journal of Prosthetic Dentistry, 109(2), pp.121–128. Ender, A. & Mehl, A., 2011. Full arch scans : conventional versus digital impressions – an in-vitro study. International Journal of Computerized Dentistry, 14, pp.11–21. Eriksson, A. et al., 2002. Clinical factors and clinical variation influencing the reproducibility of interocclusal recording methods. British Dental Journal, 192(7), pp.395–400. Fang, J.-J. & Kuo, T.-H., 2008. Modelling of mandibular movement. Computers in Biology and Medicine, 38(11-12), pp.1152–62. Fenlon, M.R. & Woelfel, J.B., 1993. Condylar position recorded using leaf gauges and specific closure forces. International Journal of Prosthodontics, 6(4), pp.402–8. Fennis, W.M.M. et al., 2002. A survey of cusp fractures in a population of general dental practices. International Journal of Prosthodontics, 15(6), pp.559–563. Ferrario, V.F. et al., 1996. Open-close movements in the human temporomandibular joint: does a pure rotation around the intercondylar hinge axis e? Journal of Oral Rehabilitation, 23, pp.401–408. Ferrario, V.F. et al., 2005. Quantification of translational and gliding components in human temporomandibular joint during mouth opening. Archives of Oral Biology, 50(5), pp.507–15. Fox, S.S., 1967. The significance of errors in hinge axis location. Journal of the American Dental Association, 74(6), pp.1268–1272. Gal, J. a et al., 2004. Analysis of human mandibular mechanics based on screw theory and in vivo data. Journal of Biomechanics, 37(9), pp.1405–12. Gallo, L.M. et al., 1997. Description of mandibular finite helical axis pathways in asymptomatic subjects. Journal of Dental Research, 76(2), pp.704–713. Gallo, L.M. et al., 2006. Relevance of mandibular helical axis analysis in functional and dysfunctional TMJs. Journal of Biomechanics, 39(9), pp.1716–25. Gámez, J.C., Dib, A.K. & Espinosa de S, I.A., 2013. Face bows in the development of michigan occlusal splints. Revista Facultad de Odontología Universidad de Antioquia, 25, pp.117–131. Geiger, A., Lenz, P. & Urtasun, R., 2012. Are we ready for autonomous driving? The KITTI vision benchmark suite. In IEEE Conference on Computer Vision and Pattern Recognition. Providence, RI, pp. 3354 – 3361. Geng, J., 2011. Structured-light 3D surface imaging: a tutorial. Advances in Optics and Photonics, 3(2), p.128. Gordon, S.R., Stoffer, W.M. & Connor, S.A., 1984. Location of the terminal hinge axis and its effect on the second molar cusp position. Journal of Prosthetic Dentistry, 52(1), pp.99–105. Grant, P.G., 1973. Biomechanical significance of the instantaneous center of rotation :tThe human temporomandibular joint. Journal of Biomechanics, 6, pp.109–113. Güney, F. & Geiger, A., 2015. Displets: resolving stereo ambiguities using object knowledge. In IEEE Conference on Computer Vision and Pattern Recognition. Boston, MA, pp. 4165 – 4175. Hall-Holt, O. & Rusinkiewicz, S., 2001. Stripe boundary codes for real-time structured-light range scanning of moving objects. In Eighth IEEE International Conference on Computer Vision. Vancouver, BC, pp. 359–366. Hartley, R.I. & Zisserman, A., 2004. Multiple View Geometry in Computer Vision Second., Cambridge, UK: Cambridge University Press. Hatzi, P., Millstein, P. & Maya, A., 2001. Determining the accuracy of articulator interchangeability and hinge axis reproducibility. Journal of Prosthetic Dentistry, 85(3), pp.236–45. Hellmann, D. et al., 2013. Accuracy of transfer of bite recording to simulated prosthetic reconstructions. Clinical Oral Investigations, 17(1), pp.259–267. Hindle, J.R. & Craddock, H.L., 2006. The use of articulators in UK dental schools. European Journal of Dental Education, 10(4), pp.197–203. Hoang, T. et al., 2010. Generic gamma correction for accuracy enhancement in fringe-projection profilometry. Optics Letters, 35(12), pp.1992–1994. Iwaki, Y., Wakabayashi, N. & Igarashi, Y., 2013. Dimensional accuracy of optical bite registration in single and multiple unit restorations. Operative Dentistry, 38(3), pp.309–15. Jankelson, B., 1969. Electronic control of muscle contraction--a new clinical era in occlusion and prosthodontics. Scientific and Educational Bulletin, 2(1), pp.29–31. Jaschouz, S. & Mehl, A., 2014. Reproducibility of habitual intercuspation in vivo. Journal of Dentistry, 42(2), pp.210–218. Jeon, J.H. et al., 2015. Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners. Journal of Prosthetic Dentistry, 114(4), pp.549–553. Jinbao, W., Xiaoming, X. & Jingen, S., 1988. Analysis of the open-closing movement of the human temporomandibular joint. Acta Anatomica, 133(3), pp.213–216. Karl, P.J. & Foley, T.F., 1999. The use of a deprogramming appliance to obtain centric relation records. Angle Orthodontist, 69(2), pp.117–125. Keshvad, A. & Winstanley, R.B., 2001. An appraisal of the literature on centric relation. Part III. Journal of Oral Rehabilitation, 28, pp.55–63. Keshvad, A. & Winstanley, R.B., 2000. Review An appraisal of the literature on centric relation . Part I : Centric relation. Journal of Oral Rehabilitation, 27, pp.823–833. Kois, J.C., Kois, D.E. & Chaiyabutr, Y., 2013. Occlusal errors generated at the maxillary incisal edge position related to discrepancies in the arbitrary horizontal axis location and to the thickness of the interocclusal record. Journal of Prosthetic Dentistry, 110(5), pp.414–419. Konolige, K., 2010. Projected texture stereo. In IEEE International Conference on Robotics and Automation (ICRA). Anchorage, AK, pp. 148–155. Koralakunte, P.R. & Aljanakh, M., 2014. The role of virtual articulator in prosthetic and restorative dentistry. Journal of Clinical and Diagnostic Research, 8(7), pp.ZE25–ZE28. Lau, D.L., Liu, K. & Hassebrook, L.G., 2010. Real-time three-dimensional shape measurement of moving objects without edge errors by time-synchronized structured illumination. Optics Letters, 35(14), pp.2487–2489. Lauritzen, A.G. & Bodner, G.H., 1961. Variations in location of arbitrary and true hinge axis points. Journal of Prosthetic Dentistry, 11, pp.224–229. Lauritzen, A.G. & Wolford, L., 1961. Hinge axis location on an experimental basis. Journal of Prosthetic Dentistry, 11, pp.1059–1067. Lazic, B. et al., 2006. Intercondylar distances of the human temporomandibular joints. Collegium Antropologicum, 30(1), pp.37–41. Li, Z. & Li, Y., 2011. Gamma-distorted fringe image modeling and accurate gamma correction for fast phase measuring profilometry. Optics Letters, 36(2), pp.154–156. Lindauer, S.J. et al., 1995. Condylar movement and mandibular rotation during jaw opening. American Journal of Orthodontics and Dentofacial Orthopedics, 107(6), pp.573–577. Liu, K. et al., 2010a. Dual-frequency pattern scheme for high-speed 3-D shape measurement. Optics Express, 18(5), pp.5229–5244. Liu, K. et al., 2010b. Gamma model and its analysis for phase measuring profilometry. Journal of the Optical Society of America., 27(3), pp.553–562. Lohot, P.M. & Sonawane, B.M., 2015. A new approach for stereo matching algorithm with dynamic programming. International Journal on Recent and Innovation Trends in Computing and Communication, 3(2), pp.691–696. Long, J.H., 1973. Locating centric relation with a leaf gauge. Journal of Prosthetic Dentistry, 29(6), pp.608–610. Long, J.H., 1970. Location of the terminal hinge axis by intraoral means. Journal of Prosthetic Dentistry, 23(1), pp.11–24. Lucia, V.O., 1960. Centric relation — theory and practice. Journal of Prosthetic Dentistry, 10(5), pp.849–856. Lucia, V.O., 1964. Technique for recording centric relation. Journal of Prosthetic Dentistry, 14, p.492. Lumley, T. et al., 2002. The importance of the normality assumption in large public health data sets. Annual Reviews of Public Health, 23, pp.151–169. Lux, L.H. et al., 2015. Comparison of the Kois Dento-Facial Analyzer System with an earbow for mounting a maxillary cast. Journal of Prosthetic Dentistry, 114(3), pp.432–439. Maestre-ferrín, L. et al., 2012. Virtual articulator for the analysis of dental occlusion: An update. Medicina Oral, Patología Oral y Cirugía Bucal, 17(1), pp.e160–e163. Magne, P., Gallucci, G.O. & Belser, U.C., 2016. Anatomic crown width/length ratios of unworn and worn maxillary teeth in white subjects. Journal of Prosthetic Dentistry, 89(5), pp.453–461. Magnusson, M., 2009. The three-dimensional normal-distributions transform — an efficient representation for registration, surface analysis, and loop detection. PhD thesis, Orebro University, Sweden. Mandilaris, C.B., Beard, C.C. & Clayton, J.A., 1992. Comparison of the intercondylar distance and the interfacial width as used with the electronic pantograph. Journal of Prosthetic Dentistry, 67(3), pp.331–334. McCollum, B.B. & Stuart, C.E., 1955. A research report. A basic text for post graduate courses in gnathology, Ventura, Ca.: Chas. E. Stuart. Available at: http://catalog.hathitrust.org/Record/000300228 [Accessed May 2, 2016]. McKee, J.R., 1997. Comparing condylar position repeatability for standardized versus nonstandardized methods of achieving centric relation. Journal of Prosthetic Dentistry, 77(3), pp.280–4. McKee, J.R., 2005. Comparing condylar positions achieved through bimanual manipulation to condylar positions achieved through masticatory muscle contraction against an anterior deprogrammer: a pilot study. Journal of Prosthetic Dentistry, 94(4), pp.389–93. McMillan, A.S., McMillan, D.R. & Darvell, B.W., 1989. Centers of rotation during jaw movements. Acta Odontologica Scandinavica, 47(5), pp.323–328. McMillan, D.R. & McMillan, A.S., 1986. A comparison of habitual jaw movements and articulator function. Acta Odontologica Scandinavica, 44(5), pp.291–299. McNamara, J.A., 1973. The independent functions of the two heads of the lateral pterygoid muscle. American Journal of Anatomy, 138, pp.197–205. Millet, C. et al., 2003. Report on the determination of occlusal vertical dimension and centric relation using swallowing in edentulous patients. Journal of Oral Rehabilitation, 30(11), pp.1118–1122. Mohan, D. & Ram, A.R., 2015. A review on depth estimation for computer vision applications. International Journal on Recent and Innovation Trends in Computing and Communication, 4(11), pp.235–239. Moreno, D., Son, K. & Taubin, G., 2015. Embedded phase shifting: robust phase shifting with embedded signals. In IEEE Conference on Computer Vision and Pattern Recognition (CVPR). Boston, MA, pp. 2301–2309. Morneburg, T.R. & Pröschel, P.A., 2011. Impact of arbitrary and mean transfer of dental casts to the articulator on centric occlusal errors. Clinical Oral Investigations, 15(3), pp.427–434. Morneburg, T.R. & Pröschel, P.A., 2002. Predicted incidence of occlusal errors in centric closing around arbitrary axes. International Journal of Prosthodontics, 15(4), pp.358–64. Müller, H.C., 2010. Registration of occlusion by buccal scan in Cerec software version 3.80. International Journal of Computerized Dentistry, 13(3), pp.265–273. Nagy, W.W., Smithy, T.J. & Wirth, C.G., 2002. Accuracy of a predetermined transverse horizontal mandibular axis point. Journal of Prosthetic Dentistry, 87(4), pp.387–394. Ohm, E. & Silness, J., 1982. The size of the Balkwill angle and the height of the Bonwill triangle. Journal of Oral Rehabilitation, 9(4), pp.301–306. Parfitt, G.J., 1960. Measurement of the physiological mobility of individual teeth in an axial direction. Journal of Dental Research, 39, pp.608–618. Park, N. et al., 1989. Comparison of centric relation recording methods. Journal of Dental Research, 68(4), p.693. Parker, M.H. et al., 1997. Comparison of occlusal contacts in maximum intercuspation for two impression techniques. Journal of Prosthetic Dentistry, 78(3), pp.255–259. Piehslinger, E., Bauer, W. & Schmiedmayer, H.B., 1995. Computer simulation of occlusal discrepancies resulting from different mounting techniques. Journal of Prosthetic Dentistry, 74(3), pp.279–283. Posselt, U., 1956. Hinge opening axis of the mandible. Acta Odontologica Scandinavica, 14(1), pp.49–63. Posselt, U., 1952. Studies in the mobility of the human mandible. Acta Odontologica Scandinavica, 10(Suppl 10), pp.19–160. Pröschel, P.A. et al., 2002. Articulator-related registration--a simple concept for minimizing eccentric occlusal errors in the articulator. International Journal of Prosthodontics, 15(3), pp.289–294. Pröschel, P.A., Maul, T. & Morneburg, T., 2000. Predicted incidence of excursive occlusal errors in common modes of articulator adjustment. International Journal of Prosthodontics, 13(4), pp.303–10. Quoob, A., Ruge, S. & Kordab, B., 2011. GEDAS II – new possibilities in digital contact point analysis. International Journal of Computerized Dentistry, 14, pp.105–109. Ramfjord, S. & Ash, M.M., 1983. Occlusion 3rd ed., Philadelphia: WB Saunders. Razek, M.K.A., 1981. Clinical evaluation of methods used in locating the mandibular hinge axis. Journal of Prosthetic Dentistry, 46(4), pp.369–373. Reeh, E.S., Messer, H.H. & Douglas, W.H., 1989. Reduction in tooth stiffness as a result of endodontic and restorative procedures. Journal of Endodontics, 15(11), pp.512–516. Regli, C.P. & Kelly, E.K., 1967. The phenomenon of decreased mandibular arch width in opening movements. Journal of Prosthetic Dentistry, 17(1), pp.49–53. Reveredo, A.M. et al., 2013. Evaluation of active tactile perception of single tooth implant prosthesis. International Journal of Oral Implantology and Clinical Research, 4(1), pp.1–6. Roth, R. & Rolfs, D., 1981. Functional occlusion for the orthodontist, part 2. Journal of Clinical Orthodontics, 15(2), pp.100–123. Scharstein, D. et al., 2014. High-resolution stereo datasets with subpixel-accurate ground truth. In German Conference on Pattern Recognition (GCPR). Munster, DE, pp. 31–42. Schmalz, C., Forster, F. & Angelopoulou, E., 2011. Camera calibration: active versus passive targets. Optical Engineering, 50(11), p.113601. Shafagh, I., Yoder, J.L. & Thayer, K.E., 1975. Diurnal variance of centric relation position. Journal of Prosthetic Dentistry, 34(5), pp.574–582. Shodadai, S.P. et al., 2001. Is there a benefit of using an arbitrary facebow for the fabrication of a stabilization appliance? International Journal of Prosthodontics, 14(6), pp.517–522. Solaberrieta, E. et al., 2015. Comparison of a conventional and virtual occlusal record. Journal of Prosthetic Dentistry, 114(1), pp.92–97. Solaberrieta, E. et al., 2016. Determining the requirements , section quantity , and dimension of the virtual occlusal record. Journal of Prosthetic Dentistry, 115(1), pp.1–5. Sprickerhof, J. & Nüchter, A., 2011. A heuristic loop closing technique for large-scale 6d slam. Automatika, 52(3), pp.199–222. Steele, J. & O’Sullivan, I., 2011. Adult Dental Health Survey 2009, Available at: http://www.hscic.gov.uk/pubs/dentalsurveyfullreport09 [Accessed May 2, 2016]. Storey, D. & Coward, T.J., 2014. The quality of impressions for crowns and bridges: an assessment of the work received at three commercial dental laboratories. assessing qualities of impressions that may lead to occlusal discrepancies with indirect restorations. European Journal of Prosthodontics and Restorative Dentistry, 22(1), pp.11–18. Storey, D. & Coward, T.J., 2013. The quality of impressions for crowns and bridges: an assessment of the work received at three commercial dental laboratories. assessing the quality of the impressions of prepared teeth. European Journal of Prosthodontics and Restorative Dentistry, 21(2), pp.53–57. Straga, R.W., 2009. Comparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment method. MSc thesis, University of British Columbia, Vancouver, CA. Tanaka, Y. & Hattori, Y., 2012. Dimensional and occlusal accuracy of a novel three-dimensional digital model of articulated dental arches. International Journal of Prosthodontics, 26(3), pp.282–7. Taylor, M. & Prendergast, P.J., 2015. Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities? Journal of Biomechanics, 48(5), pp.767–78. Tokiwa, H. et al., 2010. Anatomical location of various condylar points for jaw movement analysis in Japanese women. Journal of Oral Rehabilitation, 37(4), pp.235–241. Tsai, R., 1987. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE Journal on Robotics and Automation, 3(4), pp.323–344. Tuppy, F. et al., 1994. The reproducibility of condylar hinge axis positions in patients, by different operators, using the electronic mandibular position indicator. Journal of Orofacial Pain, 8(3), pp.315–320. Türp, J.C., Greene, C.S. & Strub, J.R., 2008. Dental occlusion: a critical reflection on past, present and future concepts. Journal of Oral Rehabilitation, 35(6), pp.446–453. Ueda, Y. et al., 2014. Evaluation of occlusal relationship reproducibility with CAD / CAM techniques. Asian Pacific Journal of Dentistry, 14, pp.35–40. Utz, K.H. et al., 2002. Accuracy of check-bite registration and centric condylar position. Journal of Oral Rehabilitation, 29(5), pp.458–466. Van’t Spijker, A. et al., 2009. Prevalence of tooth wear in adults. International Journal of Prosthodontics, 22(1), pp.35–42. Walker, P., 1980. Discrepancies between arbitrary and true hinge axes. Journal of Prosthetic Dentistry, 43, pp.279–285. Walls, A.W., Wassell, R.W. & Steele, J.G., 1991. A comparison of two methods for locating the intercuspal position (ICP) whilst mounting casts on an articulator. Journal of Oral Rehabilitation, 18(1), pp.43–48. Wang, Y. et al., 2010. Maximum SNR pattern strategy for phase shifting methods in structured light illumination. Journal of the Optical Society of America., 27(9), pp.1962–1971. Weinberg, L.A., 1972. Correlation of temporomandibular dysfunction with radiographic findings. Journal of Prosthetic Dentistry, 28(5), pp.519–539. Weinberg, L.A., 1959. The transverse hinge axis: real or imaginary. Journal of Prosthetic Dentistry, 9(5), pp.775–787. Wilson, P.H.R. & Banerjee, A., 2004. Recording the retruded contact position: a review of clinical techniques. British Dental Journal, 196(7), pp.395–402. Winstanley, R.B., Carrotte, P. V & Johnson, A., 1997. The quality of impressions for crowns and bridges received at commercial dental laboratories. British Dental Journal, 183(6), pp.209–213. Woelfel, J.B., 1986. New device for accurately recording centric relation. Journal of Prosthetic Dentistry, 56(6), pp.716–727. Wood, D.P. & Elliott, R.W., 1994. Reproducibility of the centric relation bite registration technique. Angle Orthodontist, 64(3), pp.211–220. Zatsiorsky, V., 1998. Kinematics of Human Motion, Champaign, Illinios: Human Kinetics."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.687241"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/13344/1/Keeling_AJ_Dentistry_PhD_2016.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Motivation: Dental treatments sometimes require the recording and reproduction of the patient’s transverse horizontal axis (THA). This is the axis about which the mandible will rotate, when the condyles are fully seated in their glenoid fossae. However, methods for recording this axis are rarely used in general practice, due to expense and perceived lack of efficacy. Problem Statement: A simplified method for accurately recording the THA, and interocclusal records (IORs), is needed for general dentistry. Approach: An optical 3D scanning method is proposed to kinematically record the THA. A simulation determines the required hardware specifications to build the scanner at minimal cost. The ability to record the hinge axis of a dental articulator is explored. High quality interocclusal optical records are essential, and these are investigated in subsequent experiments. Areas for improvements are identified and efforts are made to enhance the system speed and calibration. Results: Simulation results indicated that all 6 upper and lower anterior teeth, including 2mm of gingivae should be captured, with an accuracy of 50µm. The THA on a dental articulator could be located with a radial accuracy of 2.65±1.01mm. The repeatability (precision) of IORs showed a standard deviation of 22µm anteriorly, and a mean of 43µm posteriorly in vitro. The accuracy (trueness and precision) of the IORs was -15±22µm anteriorly, and up to -93±121µm posteriorly in vitro. A faster scanning protocol enabled in vivo testing. 29 IORs of a single subject took <2s to perform. The registrations showed a repeatability of 31µm anteriorly and 70µm posteriorly. A novel calibration process produced significantly reduced stereo reprojection errors compared to traditional methods (0.22 vs 0.27 pixels), offering a potential future system enhancement. Conclusions: The proposed method shows potential to improve the speed, accuracy and simplicity with which the THA, and interocclusal registration, can be recorded. Further developments have been suggested prior to embarking on clinical trials."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Determination of the Transverse Horizontal Axis and Interocclusal Registration Using a Novel Optical Technique"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wood, David","Brunton, Paul","Holt, Raymond","Franklin, Paul"],"dc:creator":["Keeling, Andrew James"],"dc:date":["2016-02"],"dc:date.issued":["2016-02"],"dc:description.abstract":["Motivation: Dental treatments sometimes require the recording and reproduction of the patient’s transverse horizontal axis (THA). This is the axis about which the mandible will rotate, when the condyles are fully seated in their glenoid fossae. However, methods for recording this axis are rarely used in general practice, due to expense and perceived lack of efficacy. Problem Statement: A simplified method for accurately recording the THA, and interocclusal records (IORs), is needed for general dentistry. Approach: An optical 3D scanning method is proposed to kinematically record the THA. A simulation determines the required hardware specifications to build the scanner at minimal cost. The ability to record the hinge axis of a dental articulator is explored. High quality interocclusal optical records are essential, and these are investigated in subsequent experiments. Areas for improvements are identified and efforts are made to enhance the system speed and calibration. Results: Simulation results indicated that all 6 upper and lower anterior teeth, including 2mm of gingivae should be captured, with an accuracy of 50µm. The THA on a dental articulator could be located with a radial accuracy of 2.65±1.01mm. The repeatability (precision) of IORs showed a standard deviation of 22µm anteriorly, and a mean of 43µm posteriorly in vitro. The accuracy (trueness and precision) of the IORs was -15±22µm anteriorly, and up to -93±121µm posteriorly in vitro. A faster scanning protocol enabled in vivo testing. 29 IORs of a single subject took <2s to perform. The registrations showed a repeatability of 31µm anteriorly and 70µm posteriorly. A novel calibration process produced significantly reduced stereo reprojection errors compared to traditional methods (0.22 vs 0.27 pixels), offering a potential future system enhancement. Conclusions: The proposed method shows potential to improve the speed, accuracy and simplicity with which the THA, and interocclusal registration, can be recorded. Further developments have been suggested prior to embarking on clinical trials."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.687241"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/13344/1/Keeling_AJ_Dentistry_PhD_2016.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Restorative Dentistry (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/13344/"],"dc:relation.references":["Academy of Denture Prosthetics, 2005. The glossary of prosthodontic terms. Journal of Prosthetic Dentistry, 94(1), pp.10–92. Adrien, P. & Schouver, J., 1997. Methods for minimizing the errors in mandibular model mounting on an articulator. Journal of Oral Rehabilitation, 24, pp.929–935. Aissaoui, A. et al., 2012. Fast stereo matching method based on optimized correlation algorithm for face depth estimation. In Proceedings of the International Conference on Computer Vision Theory and Applications (VISIGRAPP 2012). pp. 377–380. Bader, J.D., Martin, J.A. & Shugars, D.A., 2001. Incidence rates for complete cusp fracture. Community Dentistry and Oral Epidemiology, 29(5), pp.346–53. Balch, J.H., 2012. Verification of the accuracy of electronic mandibular movement recording devices: an in vitro investigation. Masters thesis, The University of Tennessee Health Science Center, USA. Balkwill, F.H., 1866. On the best form and arrangement of artificial teeth for mastication. Transactions of Great Britain Odontological Society, 5, p.133. Beard, C.C. & Clayton, J.A., 1981. Studies on the validity of the terminal hinge axis. Journal of Prosthetic Dentistry, 46(2), pp.185–191. Bennett, N., 1908. A contribution to the study of the movements of the mandible. Proceedings of the Royal Society of Medicine, Section of Odontology, April 27, pp.79–95. Bergstra, J. et al., 2010. Theano: a CPU and GPU math expression compiler. In Proceedings of the Python for Scientific Computing Conference (SciPy). Austin, TX, pp. 1–7. Bergstrom, G., 1950. On the reproduction of dental articulation by means of articulators. Acta Odontologica Scandinavica. Supplementum, 9(Suppl. 4), pp.3–149. Besl, P. & McKay, N., 1992. A method for registration of 3-D shapes. IEEE Transactions on Pattern Analysis and Machine Intelligence, 14(2), pp.239–256. De Boever, J.A., Carlsson, G.E. & Klineberg, I.J., 2000. Need for occlusal therapy and prosthodontic treatment in the management of temporomandibular disorders. Part II: tooth loss and prosthodontic treatment. Journal of Oral Rehabilitation, 27(8), pp.647–659. Bonwill, W.G.A., 1864. Articulation and articulators. Transactions of the American Dental Association, 26, pp.76–79. Bonwill, W.G.A., 1885. Geometrical and mechanical laws of articulation. Transactions of Pennsylvania Odontological Society, p.119. Bonwill, W.G.A., 1896. What has dentistry to demonstrate against the hypothesis of organic evolution ? In Transactions of the Worlds Columbian Dental Congress. Chicago, pp. 226–240. Brusco, N. et al., 2007. Metrological validation for 3D modeling of dental plaster casts. Medical Engineering & Physics, 29(9), pp.954–66. Campos, A.A., Nathanson, D. & Rose, L., 1996. Reproducibility and condylar position of a physiologic maxillomandibular centric relation in upright and supine body position. Journal of Orthodontics, 76(3), pp.282–287. Carlsson, G.E., 2010. Some dogmas related to prosthodontics, temporomandibular disorders and occlusion. Acta Odontologica Scandinavica, 68(6), pp.313–322. Celenza, F. V, 1973. The centric position: replacement and character. Journal of Prosthetic Dentistry, 30(4), pp.591–598. Chasles, M., 1830. Note sur les proprietes generales du systeme de deux corps semblables entr’eux. Bulletin de Sciences Mathematiques, Astronomiques Physiques et Chimiques, Baron de Ferussac, Paris, pp.321–326. Chen, D.C. et al., 2000. Contributing factors of mandibular deformation during mouth opening. Journal of Dentistry, 28(8), pp.583–588. Chen, X., 1998. The instantaneous center of rotation during human jaw opening and its significance in interpreting the functional meaning of condylar translation. American Journal of Physical Anthropology, 106(1), pp.35–46. Choi, D.G. et al., 1999. Reliability of an ear-bow arbitrary face-bow transfer instrument. Journal of Prosthetic Dentistry, 82(2), pp.150–156. Cioffi, I. et al., 2015. Short-term sensorimotor effects of experimental occlusal interferences on the wake-time masseter muscle activity of females with masticatory muscle pain. Journal of Oral & Facial Pain and Headache, 29(4), pp.331–339. Clark, D.M., Oyen, O.J. & Feil, P., 2001. The use of specific dental school-taught restorative techniques by practicing clinicians. Journal of Dental Education, 65(8), pp.760–5. Clark, J.R. & Evans, R.D., 2001. Functional occlusion: I. A review. Journal of Orthodontics, 28(1), pp.76–81. Davies, S. & Gray, R.M., 2001. What is occlusion? British Dental Journal, 191(5), pp.235–238, 241–245. Davies, S.J., Gray, R.M. & Smith, P.W., 2001. Good occlusal practice in simple restorative dentistry. British Dental Journal, 191(7), pp.365–381. Dawson, P., 1989. Evaluation, diagnosis and treatment of occlusal problems. 2nd ed., St Louis: Elsevier. DeLong, R. et al., 2007. Accuracy of contacts calculated from 3D images of occlusal surfaces. Journal of Dentistry, 35(6), pp.528–534. Delong, R. et al., 2002. Comparing maximum intercuspal contacts of virtual dental patients and mounted dental casts. Journal of Prosthetic Dentistry, 88(6), pp.622–630. DeLong, R. et al., 2002. Helical axis errors affect computer-generated occlusal contacts. Journal of Dental Research, 81(5), pp.338–343. Donovan, T.E. & Chee, W.W.L., 2004. A review of contemporary impression materials and techniques. Dental Clinics of North America, 48, pp.445–70. Ender, A., Attin, T. & Mehl, A., 2016. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. Journal of Prosthetic Dentistry, 115(3), pp.313–320. Ender, A. & Mehl, A., 2013. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. Journal of Prosthetic Dentistry, 109(2), pp.121–128. Ender, A. & Mehl, A., 2011. Full arch scans : conventional versus digital impressions – an in-vitro study. International Journal of Computerized Dentistry, 14, pp.11–21. Eriksson, A. et al., 2002. Clinical factors and clinical variation influencing the reproducibility of interocclusal recording methods. British Dental Journal, 192(7), pp.395–400. Fang, J.-J. & Kuo, T.-H., 2008. Modelling of mandibular movement. Computers in Biology and Medicine, 38(11-12), pp.1152–62. Fenlon, M.R. & Woelfel, J.B., 1993. Condylar position recorded using leaf gauges and specific closure forces. International Journal of Prosthodontics, 6(4), pp.402–8. Fennis, W.M.M. et al., 2002. A survey of cusp fractures in a population of general dental practices. International Journal of Prosthodontics, 15(6), pp.559–563. Ferrario, V.F. et al., 1996. Open-close movements in the human temporomandibular joint: does a pure rotation around the intercondylar hinge axis e? Journal of Oral Rehabilitation, 23, pp.401–408. Ferrario, V.F. et al., 2005. Quantification of translational and gliding components in human temporomandibular joint during mouth opening. Archives of Oral Biology, 50(5), pp.507–15. Fox, S.S., 1967. The significance of errors in hinge axis location. Journal of the American Dental Association, 74(6), pp.1268–1272. Gal, J. a et al., 2004. Analysis of human mandibular mechanics based on screw theory and in vivo data. Journal of Biomechanics, 37(9), pp.1405–12. Gallo, L.M. et al., 1997. Description of mandibular finite helical axis pathways in asymptomatic subjects. Journal of Dental Research, 76(2), pp.704–713. Gallo, L.M. et al., 2006. Relevance of mandibular helical axis analysis in functional and dysfunctional TMJs. Journal of Biomechanics, 39(9), pp.1716–25. Gámez, J.C., Dib, A.K. & Espinosa de S, I.A., 2013. Face bows in the development of michigan occlusal splints. Revista Facultad de Odontología Universidad de Antioquia, 25, pp.117–131. Geiger, A., Lenz, P. & Urtasun, R., 2012. Are we ready for autonomous driving? The KITTI vision benchmark suite. In IEEE Conference on Computer Vision and Pattern Recognition. Providence, RI, pp. 3354 – 3361. Geng, J., 2011. Structured-light 3D surface imaging: a tutorial. Advances in Optics and Photonics, 3(2), p.128. Gordon, S.R., Stoffer, W.M. & Connor, S.A., 1984. Location of the terminal hinge axis and its effect on the second molar cusp position. Journal of Prosthetic Dentistry, 52(1), pp.99–105. Grant, P.G., 1973. Biomechanical significance of the instantaneous center of rotation :tThe human temporomandibular joint. Journal of Biomechanics, 6, pp.109–113. Güney, F. & Geiger, A., 2015. Displets: resolving stereo ambiguities using object knowledge. In IEEE Conference on Computer Vision and Pattern Recognition. Boston, MA, pp. 4165 – 4175. Hall-Holt, O. & Rusinkiewicz, S., 2001. Stripe boundary codes for real-time structured-light range scanning of moving objects. In Eighth IEEE International Conference on Computer Vision. Vancouver, BC, pp. 359–366. Hartley, R.I. & Zisserman, A., 2004. Multiple View Geometry in Computer Vision Second., Cambridge, UK: Cambridge University Press. Hatzi, P., Millstein, P. & Maya, A., 2001. Determining the accuracy of articulator interchangeability and hinge axis reproducibility. Journal of Prosthetic Dentistry, 85(3), pp.236–45. Hellmann, D. et al., 2013. Accuracy of transfer of bite recording to simulated prosthetic reconstructions. Clinical Oral Investigations, 17(1), pp.259–267. Hindle, J.R. & Craddock, H.L., 2006. The use of articulators in UK dental schools. European Journal of Dental Education, 10(4), pp.197–203. Hoang, T. et al., 2010. Generic gamma correction for accuracy enhancement in fringe-projection profilometry. Optics Letters, 35(12), pp.1992–1994. Iwaki, Y., Wakabayashi, N. & Igarashi, Y., 2013. Dimensional accuracy of optical bite registration in single and multiple unit restorations. Operative Dentistry, 38(3), pp.309–15. Jankelson, B., 1969. Electronic control of muscle contraction--a new clinical era in occlusion and prosthodontics. Scientific and Educational Bulletin, 2(1), pp.29–31. Jaschouz, S. & Mehl, A., 2014. Reproducibility of habitual intercuspation in vivo. Journal of Dentistry, 42(2), pp.210–218. Jeon, J.H. et al., 2015. Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners. Journal of Prosthetic Dentistry, 114(4), pp.549–553. Jinbao, W., Xiaoming, X. & Jingen, S., 1988. Analysis of the open-closing movement of the human temporomandibular joint. Acta Anatomica, 133(3), pp.213–216. Karl, P.J. & Foley, T.F., 1999. The use of a deprogramming appliance to obtain centric relation records. Angle Orthodontist, 69(2), pp.117–125. Keshvad, A. & Winstanley, R.B., 2001. An appraisal of the literature on centric relation. Part III. Journal of Oral Rehabilitation, 28, pp.55–63. Keshvad, A. & Winstanley, R.B., 2000. Review An appraisal of the literature on centric relation . Part I : Centric relation. Journal of Oral Rehabilitation, 27, pp.823–833. Kois, J.C., Kois, D.E. & Chaiyabutr, Y., 2013. Occlusal errors generated at the maxillary incisal edge position related to discrepancies in the arbitrary horizontal axis location and to the thickness of the interocclusal record. Journal of Prosthetic Dentistry, 110(5), pp.414–419. Konolige, K., 2010. Projected texture stereo. In IEEE International Conference on Robotics and Automation (ICRA). Anchorage, AK, pp. 148–155. Koralakunte, P.R. & Aljanakh, M., 2014. The role of virtual articulator in prosthetic and restorative dentistry. Journal of Clinical and Diagnostic Research, 8(7), pp.ZE25–ZE28. Lau, D.L., Liu, K. & Hassebrook, L.G., 2010. Real-time three-dimensional shape measurement of moving objects without edge errors by time-synchronized structured illumination. Optics Letters, 35(14), pp.2487–2489. Lauritzen, A.G. & Bodner, G.H., 1961. Variations in location of arbitrary and true hinge axis points. Journal of Prosthetic Dentistry, 11, pp.224–229. Lauritzen, A.G. & Wolford, L., 1961. Hinge axis location on an experimental basis. Journal of Prosthetic Dentistry, 11, pp.1059–1067. Lazic, B. et al., 2006. Intercondylar distances of the human temporomandibular joints. Collegium Antropologicum, 30(1), pp.37–41. Li, Z. & Li, Y., 2011. Gamma-distorted fringe image modeling and accurate gamma correction for fast phase measuring profilometry. Optics Letters, 36(2), pp.154–156. Lindauer, S.J. et al., 1995. Condylar movement and mandibular rotation during jaw opening. American Journal of Orthodontics and Dentofacial Orthopedics, 107(6), pp.573–577. Liu, K. et al., 2010a. Dual-frequency pattern scheme for high-speed 3-D shape measurement. Optics Express, 18(5), pp.5229–5244. Liu, K. et al., 2010b. Gamma model and its analysis for phase measuring profilometry. Journal of the Optical Society of America., 27(3), pp.553–562. Lohot, P.M. & Sonawane, B.M., 2015. A new approach for stereo matching algorithm with dynamic programming. International Journal on Recent and Innovation Trends in Computing and Communication, 3(2), pp.691–696. Long, J.H., 1973. Locating centric relation with a leaf gauge. Journal of Prosthetic Dentistry, 29(6), pp.608–610. Long, J.H., 1970. Location of the terminal hinge axis by intraoral means. Journal of Prosthetic Dentistry, 23(1), pp.11–24. Lucia, V.O., 1960. Centric relation — theory and practice. Journal of Prosthetic Dentistry, 10(5), pp.849–856. Lucia, V.O., 1964. Technique for recording centric relation. Journal of Prosthetic Dentistry, 14, p.492. Lumley, T. et al., 2002. The importance of the normality assumption in large public health data sets. Annual Reviews of Public Health, 23, pp.151–169. Lux, L.H. et al., 2015. Comparison of the Kois Dento-Facial Analyzer System with an earbow for mounting a maxillary cast. Journal of Prosthetic Dentistry, 114(3), pp.432–439. Maestre-ferrín, L. et al., 2012. Virtual articulator for the analysis of dental occlusion: An update. Medicina Oral, Patología Oral y Cirugía Bucal, 17(1), pp.e160–e163. Magne, P., Gallucci, G.O. & Belser, U.C., 2016. Anatomic crown width/length ratios of unworn and worn maxillary teeth in white subjects. Journal of Prosthetic Dentistry, 89(5), pp.453–461. Magnusson, M., 2009. The three-dimensional normal-distributions transform — an efficient representation for registration, surface analysis, and loop detection. PhD thesis, Orebro University, Sweden. Mandilaris, C.B., Beard, C.C. & Clayton, J.A., 1992. Comparison of the intercondylar distance and the interfacial width as used with the electronic pantograph. Journal of Prosthetic Dentistry, 67(3), pp.331–334. McCollum, B.B. & Stuart, C.E., 1955. A research report. A basic text for post graduate courses in gnathology, Ventura, Ca.: Chas. E. Stuart. Available at: http://catalog.hathitrust.org/Record/000300228 [Accessed May 2, 2016]. McKee, J.R., 1997. Comparing condylar position repeatability for standardized versus nonstandardized methods of achieving centric relation. Journal of Prosthetic Dentistry, 77(3), pp.280–4. McKee, J.R., 2005. Comparing condylar positions achieved through bimanual manipulation to condylar positions achieved through masticatory muscle contraction against an anterior deprogrammer: a pilot study. Journal of Prosthetic Dentistry, 94(4), pp.389–93. McMillan, A.S., McMillan, D.R. & Darvell, B.W., 1989. Centers of rotation during jaw movements. Acta Odontologica Scandinavica, 47(5), pp.323–328. McMillan, D.R. & McMillan, A.S., 1986. A comparison of habitual jaw movements and articulator function. Acta Odontologica Scandinavica, 44(5), pp.291–299. McNamara, J.A., 1973. The independent functions of the two heads of the lateral pterygoid muscle. American Journal of Anatomy, 138, pp.197–205. Millet, C. et al., 2003. Report on the determination of occlusal vertical dimension and centric relation using swallowing in edentulous patients. Journal of Oral Rehabilitation, 30(11), pp.1118–1122. Mohan, D. & Ram, A.R., 2015. A review on depth estimation for computer vision applications. International Journal on Recent and Innovation Trends in Computing and Communication, 4(11), pp.235–239. Moreno, D., Son, K. & Taubin, G., 2015. Embedded phase shifting: robust phase shifting with embedded signals. In IEEE Conference on Computer Vision and Pattern Recognition (CVPR). Boston, MA, pp. 2301–2309. Morneburg, T.R. & Pröschel, P.A., 2011. Impact of arbitrary and mean transfer of dental casts to the articulator on centric occlusal errors. Clinical Oral Investigations, 15(3), pp.427–434. Morneburg, T.R. & Pröschel, P.A., 2002. Predicted incidence of occlusal errors in centric closing around arbitrary axes. International Journal of Prosthodontics, 15(4), pp.358–64. Müller, H.C., 2010. Registration of occlusion by buccal scan in Cerec software version 3.80. International Journal of Computerized Dentistry, 13(3), pp.265–273. Nagy, W.W., Smithy, T.J. & Wirth, C.G., 2002. Accuracy of a predetermined transverse horizontal mandibular axis point. Journal of Prosthetic Dentistry, 87(4), pp.387–394. Ohm, E. & Silness, J., 1982. The size of the Balkwill angle and the height of the Bonwill triangle. Journal of Oral Rehabilitation, 9(4), pp.301–306. Parfitt, G.J., 1960. Measurement of the physiological mobility of individual teeth in an axial direction. Journal of Dental Research, 39, pp.608–618. Park, N. et al., 1989. Comparison of centric relation recording methods. Journal of Dental Research, 68(4), p.693. Parker, M.H. et al., 1997. Comparison of occlusal contacts in maximum intercuspation for two impression techniques. Journal of Prosthetic Dentistry, 78(3), pp.255–259. Piehslinger, E., Bauer, W. & Schmiedmayer, H.B., 1995. Computer simulation of occlusal discrepancies resulting from different mounting techniques. Journal of Prosthetic Dentistry, 74(3), pp.279–283. Posselt, U., 1956. Hinge opening axis of the mandible. Acta Odontologica Scandinavica, 14(1), pp.49–63. Posselt, U., 1952. Studies in the mobility of the human mandible. Acta Odontologica Scandinavica, 10(Suppl 10), pp.19–160. Pröschel, P.A. et al., 2002. Articulator-related registration--a simple concept for minimizing eccentric occlusal errors in the articulator. International Journal of Prosthodontics, 15(3), pp.289–294. Pröschel, P.A., Maul, T. & Morneburg, T., 2000. Predicted incidence of excursive occlusal errors in common modes of articulator adjustment. International Journal of Prosthodontics, 13(4), pp.303–10. Quoob, A., Ruge, S. & Kordab, B., 2011. GEDAS II – new possibilities in digital contact point analysis. International Journal of Computerized Dentistry, 14, pp.105–109. Ramfjord, S. & Ash, M.M., 1983. Occlusion 3rd ed., Philadelphia: WB Saunders. Razek, M.K.A., 1981. Clinical evaluation of methods used in locating the mandibular hinge axis. Journal of Prosthetic Dentistry, 46(4), pp.369–373. Reeh, E.S., Messer, H.H. & Douglas, W.H., 1989. Reduction in tooth stiffness as a result of endodontic and restorative procedures. Journal of Endodontics, 15(11), pp.512–516. Regli, C.P. & Kelly, E.K., 1967. The phenomenon of decreased mandibular arch width in opening movements. Journal of Prosthetic Dentistry, 17(1), pp.49–53. Reveredo, A.M. et al., 2013. Evaluation of active tactile perception of single tooth implant prosthesis. International Journal of Oral Implantology and Clinical Research, 4(1), pp.1–6. Roth, R. & Rolfs, D., 1981. Functional occlusion for the orthodontist, part 2. Journal of Clinical Orthodontics, 15(2), pp.100–123. Scharstein, D. et al., 2014. High-resolution stereo datasets with subpixel-accurate ground truth. In German Conference on Pattern Recognition (GCPR). Munster, DE, pp. 31–42. Schmalz, C., Forster, F. & Angelopoulou, E., 2011. Camera calibration: active versus passive targets. Optical Engineering, 50(11), p.113601. Shafagh, I., Yoder, J.L. & Thayer, K.E., 1975. Diurnal variance of centric relation position. Journal of Prosthetic Dentistry, 34(5), pp.574–582. Shodadai, S.P. et al., 2001. Is there a benefit of using an arbitrary facebow for the fabrication of a stabilization appliance? International Journal of Prosthodontics, 14(6), pp.517–522. Solaberrieta, E. et al., 2015. Comparison of a conventional and virtual occlusal record. Journal of Prosthetic Dentistry, 114(1), pp.92–97. Solaberrieta, E. et al., 2016. Determining the requirements , section quantity , and dimension of the virtual occlusal record. Journal of Prosthetic Dentistry, 115(1), pp.1–5. Sprickerhof, J. & Nüchter, A., 2011. A heuristic loop closing technique for large-scale 6d slam. Automatika, 52(3), pp.199–222. Steele, J. & O’Sullivan, I., 2011. Adult Dental Health Survey 2009, Available at: http://www.hscic.gov.uk/pubs/dentalsurveyfullreport09 [Accessed May 2, 2016]. Storey, D. & Coward, T.J., 2014. The quality of impressions for crowns and bridges: an assessment of the work received at three commercial dental laboratories. assessing qualities of impressions that may lead to occlusal discrepancies with indirect restorations. European Journal of Prosthodontics and Restorative Dentistry, 22(1), pp.11–18. Storey, D. & Coward, T.J., 2013. The quality of impressions for crowns and bridges: an assessment of the work received at three commercial dental laboratories. assessing the quality of the impressions of prepared teeth. European Journal of Prosthodontics and Restorative Dentistry, 21(2), pp.53–57. Straga, R.W., 2009. Comparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment method. MSc thesis, University of British Columbia, Vancouver, CA. Tanaka, Y. & Hattori, Y., 2012. Dimensional and occlusal accuracy of a novel three-dimensional digital model of articulated dental arches. International Journal of Prosthodontics, 26(3), pp.282–7. Taylor, M. & Prendergast, P.J., 2015. Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities? Journal of Biomechanics, 48(5), pp.767–78. Tokiwa, H. et al., 2010. Anatomical location of various condylar points for jaw movement analysis in Japanese women. Journal of Oral Rehabilitation, 37(4), pp.235–241. Tsai, R., 1987. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE Journal on Robotics and Automation, 3(4), pp.323–344. Tuppy, F. et al., 1994. The reproducibility of condylar hinge axis positions in patients, by different operators, using the electronic mandibular position indicator. Journal of Orofacial Pain, 8(3), pp.315–320. Türp, J.C., Greene, C.S. & Strub, J.R., 2008. Dental occlusion: a critical reflection on past, present and future concepts. Journal of Oral Rehabilitation, 35(6), pp.446–453. Ueda, Y. et al., 2014. Evaluation of occlusal relationship reproducibility with CAD / CAM techniques. Asian Pacific Journal of Dentistry, 14, pp.35–40. Utz, K.H. et al., 2002. Accuracy of check-bite registration and centric condylar position. Journal of Oral Rehabilitation, 29(5), pp.458–466. Van’t Spijker, A. et al., 2009. Prevalence of tooth wear in adults. International Journal of Prosthodontics, 22(1), pp.35–42. Walker, P., 1980. Discrepancies between arbitrary and true hinge axes. Journal of Prosthetic Dentistry, 43, pp.279–285. Walls, A.W., Wassell, R.W. & Steele, J.G., 1991. A comparison of two methods for locating the intercuspal position (ICP) whilst mounting casts on an articulator. Journal of Oral Rehabilitation, 18(1), pp.43–48. Wang, Y. et al., 2010. Maximum SNR pattern strategy for phase shifting methods in structured light illumination. Journal of the Optical Society of America., 27(9), pp.1962–1971. Weinberg, L.A., 1972. Correlation of temporomandibular dysfunction with radiographic findings. Journal of Prosthetic Dentistry, 28(5), pp.519–539. Weinberg, L.A., 1959. The transverse hinge axis: real or imaginary. Journal of Prosthetic Dentistry, 9(5), pp.775–787. Wilson, P.H.R. & Banerjee, A., 2004. Recording the retruded contact position: a review of clinical techniques. British Dental Journal, 196(7), pp.395–402. Winstanley, R.B., Carrotte, P. V & Johnson, A., 1997. The quality of impressions for crowns and bridges received at commercial dental laboratories. British Dental Journal, 183(6), pp.209–213. Woelfel, J.B., 1986. New device for accurately recording centric relation. Journal of Prosthetic Dentistry, 56(6), pp.716–727. Wood, D.P. & Elliott, R.W., 1994. Reproducibility of the centric relation bite registration technique. Angle Orthodontist, 64(3), pp.211–220. Zatsiorsky, V., 1998. Kinematics of Human Motion, Champaign, Illinios: Human Kinetics."],"dcterms:accessrights":["public"],"dc:title":["Determination of the Transverse Horizontal Axis and Interocclusal Registration Using a Novel Optical Technique"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T21:42:00Z"}