{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:15238"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:15238","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Transcatheter and Surgical Aortic Valve Replacement for Severe Aortic Stenosis: Insights from Cardiovascular Magnetic Resonance Imaging","abstract":"Background: Surgical aortic valve replacement (SAVR) remains first-line treatment for symptomatic severe aortic stenosis, whereas transcatheter aortic valve implantation (TAVI) is indicated in patients who are inoperable or considered too high-risk for surgery. Current focus is centred on differences in the impact of valve replacement upon cardiovascular function to guide patient selection and the development of novel prosthetic valves to improve outcomes. Cardiovascular Magnetic Resonance (CMR) imaging is the investigative modality of choice for such a purpose. Objectives: To compare the impact of SAVR and TAVI upon aortic stiffness, right ventricular function and myocardial strain, and to compare two vendor designs in the quantity of post-TAVI aortic regurgitation and reverse remodelling. Methods: A prospective study of patients with severe aortic stenosis under surveillance and subsequently requiring SAVR or TAVI, recruited between September 2009 and December 2015. A 1.5 Tesla CMR study was performed pre and 6 months post SAVR, and pre, immediately and 6 months post implantation of Medtronic CoreValve and Boston Lotus TAVI. Aortic distensibility (AD), pulse wave velocity (PWV), right ventricular (RV) volumes, myocardial strain and aortic regurgitation (AR) were quantified. Results: At 6 months, SAVR was associated with a significant worsening in PWV (6.38±4.47 vs. 11.01±5.75ms-1, p=0.001) and ascending AD (1.95±1.15 vs. 1.57±0.68x10-3mmHg-1, p=0.044), whereas no change was seen following TAVI. A significant reduction in RV ejection fraction (58±8 vs. 53±8%, p=0.005) was seen flowing SAVR, with no change following TAVI. A significant and comparable decline in LV torsion and twist was observed. Baseline circumferential strain was significantly associated with all-cause mortality (hazard ratio, 1.03; 1.01–1.05; p=0.009). Significantly less AR was seen immediately following Lotus than CoreValve TAVI (4.3±3.4 vs.11.7±8.4%, p=0.001) with equivalent degrees of reverse remodelling observed at 6 months. Conclusion: Compared with TAVI, SAVR is more detrimental upon aortic stiffness and right ventricular function at 6 months. CMR derived circumferential strain is associated with survival following SAVR and TAVI.","abstract_html":"Background: Surgical aortic valve replacement (SAVR) remains first-line treatment for symptomatic severe aortic stenosis, whereas transcatheter aortic valve implantation (TAVI) is indicated in patients who are inoperable or considered too high-risk for surgery. Current focus is centred on differences in the impact of valve replacement upon cardiovascular function to guide patient selection and the development of novel prosthetic valves to improve outcomes. Cardiovascular Magnetic Resonance (CMR) imaging is the investigative modality of choice for such a purpose. Objectives: To compare the impact of SAVR and TAVI upon aortic stiffness, right ventricular function and myocardial strain, and to compare two vendor designs in the quantity of post-TAVI aortic regurgitation and reverse remodelling. Methods: A prospective study of patients with severe aortic stenosis under surveillance and subsequently requiring SAVR or TAVI, recruited between September 2009 and December 2015. A 1.5 Tesla CMR study was performed pre and 6 months post SAVR, and pre, immediately and 6 months post implantation of Medtronic CoreValve and Boston Lotus TAVI. Aortic distensibility (AD), pulse wave velocity (PWV), right ventricular (RV) volumes, myocardial strain and aortic regurgitation (AR) were quantified. Results: At 6 months, SAVR was associated with a significant worsening in PWV (6.38±4.47 vs. 11.01±5.75ms-1, p=0.001) and ascending AD (1.95±1.15 vs. 1.57±0.68x10-3mmHg-1, p=0.044), whereas no change was seen following TAVI. A significant reduction in RV ejection fraction (58±8 vs. 53±8%, p=0.005) was seen flowing SAVR, with no change following TAVI. A significant and comparable decline in LV torsion and twist was observed. Baseline circumferential strain was significantly associated with all-cause mortality (hazard ratio, 1.03; 1.01–1.05; p=0.009). Significantly less AR was seen immediately following Lotus than CoreValve TAVI (4.3±3.4 vs.11.7±8.4%, p=0.001) with equivalent degrees of reverse remodelling observed at 6 months. Conclusion: Compared with TAVI, SAVR is more detrimental upon aortic stiffness and right ventricular function at 6 months. CMR derived circumferential strain is associated with survival following SAVR and TAVI.","abstract_has_math":false,"creators":["Musa, Tarique Al"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Greenwood, John P","Plein, Sven"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-05","date_published":"2016-05","updated_at":"2026-11-18T22:17:45Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.695953"],"render_values":[{"text":"uk.bl.ethos.695953","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["PG/11/126/29321"],"render_values":[{"text":"PG/11/126/29321","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/15238/1/TAM_PhD_Thesis_FINAL_POST_MINOR_REVISIONS.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A15238","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Greenwood, John P","Plein, Sven"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["British Heart Foundation"]},{"key":"dc:creator","label":"Author","values":["Musa, Tarique Al"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-05"]},{"key":"dc:date.issued","label":"Date","values":["2016-05"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Academic Unit of Cardiovascular Medicine (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/15238/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["2010. Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: 'establishing normal and reference values'. Eur Heart J, 31, 2338-50. ABDEL-WAHAB, M., MEHILLI, J., FRERKER, C., NEUMANN, F. J., KURZ, T., TOLG, R., ZACHOW, D., GUERRA, E., MASSBERG, S., SCHAFER, U., EL-MAWARDY, M., RICHARDT, G. & INVESTIGATORS, C. 2014. Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA, 311, 1503-14. ADAMS, D. H., POPMA, J. J., REARDON, M. J., YAKUBOV, S. J., COSELLI, J. S., DEEB, G. M., GLEASON, T. G., BUCHBINDER, M., HERMILLER, J., JR., KLEIMAN, N. S., CHETCUTI, S., HEISER, J., MERHI, W., ZORN, G., TADROS, P., ROBINSON, N., PETROSSIAN, G., HUGHES, G. C., HARRISON, J. K., CONTE, J., MAINI, B., MUMTAZ, M., CHENOWETH, S. & OH, J. K. 2014. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med, 370, 1790-8. ALI, A., PATEL, A., ALI, Z., ABU-OMAR, Y., SAEED, A., ATHANASIOU, T. & PEPPER, J. 2011. Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival. J Thorac Cardiovasc Surg, 142, 285-91. ALTIOK, E., FRICK, M., MEYER, C. G., AL ATEAH, G., NAPP, A., KIRSCHFINK, A., ALMALLA, M., LOTFI, S., BECKER, M., HERICH, L., LEHMACHER, W. & HOFFMANN, R. 2014. Comparison of two- and three-dimensional transthoracic echocardiography to cardiac magnetic resonance imaging for assessment of paravalvular regurgitation after transcatheter aortic valve implantation. Am J Cardiol, 113, 1859-66. AMBALE-VENKATESH, B. & LIMA, J. A. 2015. Cardiac MRI: a central prognostic tool in myocardial fibrosis. Nat Rev Cardiol, 12, 18-29. ANGOURAS, D., SOKOLIS, D. P., DOSIOS, T., KOSTOMITSOPOULOS, N., BOUDOULAS, H., SKALKEAS, G. & KARAYANNACOS, P. E. 2000. Effect of impaired vasa vasorum flow on the structure and mechanics of the thoracic aorta: implications for the pathogenesis of aortic dissection. Eur J Cardiothorac Surg, 17, 468-73. ASIMAKOPOULOS, G., EDWARDS, M. B. & TAYLOR, K. M. 1997. Aortic valve replacement in patients 80 years of age and older: survival and cause of death based on 1100 cases: collective results from the UK Heart Valve Registry. Circulation, 96, 3403-8. ASMAR, R., BENETOS, A., LONDON, G., HUGUE, C., WEISS, Y., TOPOUCHIAN, J., LALOUX, B. & SAFAR, M. 1995. Aortic distensibility in normotensive, untreated and treated hypertensive patients. Blood Press, 4, 48-54. ASMAR, R. G., PANNIER, B., SANTONI, J. P., LAURENT, S., LONDON, G. M., LEVY, B. I. & SAFAR, M. E. 1988. Reversion of cardiac hypertrophy and reduced arterial compliance after converting enzyme inhibition in essential hypertension. Circulation, 78, 941-50. ATHAPPAN, G., PATVARDHAN, E., TUZCU, E. M., SVENSSON, L. G., LEMOS, P. A., FRACCARO, C., TARANTINI, G., SINNING, J. M., NICKENIG, G., CAPODANNO, D., TAMBURINO, C., LATIB, A., COLOMBO, A. & KAPADIA, S. R. 2013. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol, 61, 1585-95. ATTIAS, D., MACRON, L., DREYFUS, J., MONIN, J. L., BROCHET, E., LEPAGE, L., HEKIMIAN, G., IUNG, B., VAHANIAN, A. & MESSIKA-ZEITOUN, D. 2013. Relationship between longitudinal strain and symptomatic status in aortic stenosis. J Am Soc Echocardiogr, 26, 868-74. AYHAN, H., DURMAZ, T., KELES, T., SARI, C., ASLAN, A. N., KASAPKARA, H. A. & BOZKURT, E. 2014. Improvement of right ventricular function with transcatheter aortic valve implantation. Scand Cardiovasc J, 48, 184-8. AZEVEDO, C. F., NIGRI, M., HIGUCHI, M. L., POMERANTZEFF, P. M., SPINA, G. S., SAMPAIO, R. O., TARASOUTCHI, F., GRINBERG, M. & ROCHITTE, C. E. 2010. Prognostic significance of myocardial fibrosis quantification by histopathology and magnetic resonance imaging in patients with severe aortic valve disease. J Am Coll Cardiol, 56, 278-87. BARBETSEAS, J., ALEXOPOULOS, N., BRILI, S., AGGELI, C., MARINAKIS, N., VLACHOPOULOS, C., VYSSOULIS, G. & STEFANADIS, C. 2006. Changes in aortic root function after valve replacement in patients with aortic stenosis. Int J Cardiol, 110, 74-9. BARONE-ROCHETTE, G., PIERARD, S., DE MEESTER DE RAVENSTEIN, C., SELDRUM, S., MELCHIOR, J., MAES, F., POULEUR, A. C., VANCRAEYNEST, D., PASQUET, A., VANOVERSCHELDE, J. L. & GERBER, B. L. 2014. Prognostic significance of LGE by CMR in aortic stenosis patients undergoing valve replacement. J Am Coll Cardiol, 64, 144-54. BAUER, F., LEMERCIER, M., ZAJARIAS, A., TRON, C., ELTCHANINOFF, H. & CRIBIER, A. 2010. Immediate and long-term echocardiographic findings after transcatheter aortic valve implantation for the treatment of aortic stenosis: the Cribier-Edwards/Edwards-Sapien valve experience. J Am Soc Echocardiogr, 23, 370-6. BAUMGARTNER, H., HUNG, J., BERMEJO, J., CHAMBERS, J. B., EVANGELISTA, A., GRIFFIN, B. P., IUNG, B., OTTO, C. M., PELLIKKA, P. A. & QUINONES, M. 2009. Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. Eur J Echocardiogr, 10, 1-25. BEACH, J. M., MIHALJEVIC, T., RAJESWARAN, J., MARWICK, T., EDWARDS, S. T., NOWICKI, E. R., THOMAS, J., SVENSSON, L. G., GRIFFIN, B., GILLINOV, A. M. & BLACKSTONE, E. H. 2014. Ventricular hypertrophy and left atrial dilatation persist and are associated with reduced survival after valve replacement for aortic stenosis. J Thorac Cardiovasc Surg, 147, 362-369 e8. BECKER, M., KRAMANN, R., DOHMEN, G., LUCKHOFF, A., AUTSCHBACH, R., KELM, M. & HOFFMANN, R. 2007. Impact of left ventricular loading conditions on myocardial deformation parameters: analysis of early and late changes of myocardial deformation parameters after aortic valve replacement. J Am Soc Echocardiogr, 20, 681-9. BELLENGER, N. G., BURGESS, M. I., RAY, S. G., LAHIRI, A., COATS, A. J., CLELAND, J. G. & PENNELL, D. J. 2000a. Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J, 21, 1387-96. BELLENGER, N. G., DAVIES, L. C., FRANCIS, J. M., COATS, A. J. & PENNELL, D. J. 2000b. Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Magn Reson, 2, 271-8. BERRY, C., LLOYD, S. M., WANG, Y., MACDONALD, A. & FORD, I. 2013. The changing course of aortic valve disease in Scotland: temporal trends in hospitalizations and mortality and prognostic importance of aortic stenosis. Eur Heart J, 34, 1538-47. BIEDERMAN, R. W., DOYLE, M., YAMROZIK, J., WILLIAMS, R. B., RATHI, V. K., VIDO, D., CARUPPANNAN, K., OSMAN, N., BRESS, V., RAYARAO, G., BIEDERMAN, C. M., MANKAD, S., MAGOVERN, J. A. & REICHEK, N. 2005. Physiologic compensation is supranormal in compensated aortic stenosis: does it return to normal after aortic valve replacement or is it blunted by coexistent coronary artery disease? An intramyocardial magnetic resonance imaging study. Circulation, 112, I429-36. BINDER, R. K. & WEBB, J. G. 2012. TAVI: from home-made prosthesis to global interventional phenomenon. Heart, 98 Suppl 4, iv30-6. BITEKER, M., OZDEN, T., DAYAN, A., TEKKESIN, A. I. & MISIRLI, C. H. 2015. Aortic stiffness and plasma brain natriuretic peptide predicts mortality in acute ischemic stroke. Int J Stroke, 10, 679-85. BLUMENSTEIN, J., LIEBETRAU, C., VAN LINDEN, A., MOELLMANN, H., WALTHER, T. & KEMPFERT, J. 2013. Recent advances in transcatheter aortic valve implantation: novel devices and potential shortcomings. Curr Cardiol Rev, 9, 274-80. BOCK, J., FRYDRYCHOWICZ, A., LORENZ, R., HIRTLER, D., BARKER, A. J., JOHNSON, K. M., ARNOLD, R., BURKHARDT, H., HENNIG, J. & MARKL, M. 2011. In vivo noninvasive 4D pressure difference mapping in the human aorta: phantom comparison and application in healthy volunteers and patients. Magn Reson Med, 66, 1079-88. BRIAND, M., DUMESNIL, J. G., KADEM, L., TONGUE, A. G., RIEU, R., GARCIA, D. & PIBAROT, P. 2005. Reduced systemic arterial compliance impacts significantly on left ventricular afterload and function in aortic stenosis: implications for diagnosis and treatment. J Am Coll Cardiol, 46, 291-8. CARASSO, S., COHEN, O., MUTLAK, D., ADLER, Z., LESSICK, J., ARONSON, D., REISNER, S. A., RAKOWSKI, H., BOLOTIN, G. & AGMON, Y. 2011. Relation of myocardial mechanics in severe aortic stenosis to left ventricular ejection fraction and response to aortic valve replacement. Am J Cardiol, 107, 1052-7. CARASSO, S., COHEN, O., MUTLAK, D., ADLER, Z., LESSICK, J., REISNER, S. A., RAKOWSKI, H., BOLOTIN, G. & AGMON, Y. 2009. Differential effects of afterload on left ventricular long- and short-axis function: insights from a clinical model of patients with aortic valve stenosis undergoing aortic valve replacement. Am Heart J, 158, 540-5. CARASSO, S., MUTLAK, D., LESSICK, J., REISNER, S. A., RAKOWSKI, H. & AGMON, Y. 2015. Symptoms in severe aortic stenosis are associated with decreased compensatory circumferential myocardial mechanics. J Am Soc Echocardiogr, 28, 218-25. CARR-WHITE, G. S., KON, M., KOH, T. W., GLENNAN, S., FERDINAND, F. D., DE SOUZA, A. C., PEPPER, J. R., PENNELL, D. J., GIBSON, D. G. & YACOUB, M. H. 1999. Right ventricular function after pulmonary autograft replacement of the aortic valve. Circulation, 100, II36-41. CAVALCANTE, J. L., LIMA, J. A., REDHEUIL, A. & AL-MALLAH, M. H. 2011. Aortic stiffness: current understanding and future directions. J Am Coll Cardiol, 57, 1511-22. CAWLEY, P. J., HAMILTON-CRAIG, C., OWENS, D. S., KRIEGER, E. V., STRUGNELL, W. E., MITSUMORI, L., D'JANG, C. L., SCHWAEGLER, R. G., NGUYEN, K. Q., NGUYEN, B., MAKI, J. H. & OTTO, C. M. 2013. Prospective comparison of valve regurgitation quantitation by cardiac magnetic resonance imaging and transthoracic echocardiography. Circ Cardiovasc Imaging, 6, 48-57. CHALMERS, J., PULLAN, M., MEDIRATTA, N. & POULLIS, M. 2014. A need for speed? Bypass time and outcomes after isolated aortic valve replacement surgery. Interact Cardiovasc Thorac Surg, 19, 21-6. CHILDS, H., MA, L., MA, M., CLARKE, J., COCKER, M., GREEN, J., STROHM, O. & FRIEDRICH, M. G. 2011. Comparison of long and short axis quantification of left ventricular volume parameters by cardiovascular magnetic resonance, with ex-vivo validation. J Cardiovasc Magn Reson, 13, 40. CHIN, C. W., PAWADE, T. A., NEWBY, D. E. & DWECK, M. R. 2015. Risk Stratification in Patients With Aortic Stenosis Using Novel Imaging Approaches. Circ Cardiovasc Imaging, 8, e003421. CHIN, C. W., SHAH, A. S., MCALLISTER, D. A., JOANNA COWELL, S., ALAM, S., LANGRISH, J. P., STRACHAN, F. E., HUNTER, A. L., MARIA CHOY, A., LANG, C. C., WALKER, S., BOON, N. A., NEWBY, D. E., MILLS, N. L. & DWECK, M. R. 2014a. High-sensitivity troponin I concentrations are a marker of an advanced hypertrophic response and adverse outcomes in patients with aortic stenosis. Eur Heart J, 35, 2312-21. CHIN, C. W., VASSILIOU, V., JENKINS, W. S., PRASAD, S. K., NEWBY, D. E. & DWECK, M. R. 2014b. Markers of left ventricular decompensation in aortic stenosis. Expert Rev Cardiovasc Ther, 12, 901-12. CLAVEL, M. A., WEBB, J. G., RODES-CABAU, J., MASSON, J. B., DUMONT, E., DE LAROCHELLIERE, R., DOYLE, D., BERGERON, S., BAUMGARTNER, H., BURWASH, I. G., DUMESNIL, J. G., MUNDIGLER, G., MOSS, R., KEMPNY, A., BAGUR, R., BERGLER-KLEIN, J., GURVITCH, R., MATHIEU, P. & PIBAROT, P. 2010. Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction. Circulation, 122, 1928-36. CLAYTON, B., MORGAN-HUGHES, G. & ROOBOTTOM, C. 2014. Transcatheter aortic valve insertion (TAVI): a review. Br J Radiol, 87, 20130595. COSTOPOULOS, C., NAGANUMA, T., LATIB, A. & COLOMBO, A. 2013. Aortic regurgitation after transcatheter aortic valve implantation. Expert Rev Cardiovasc Ther, 11, 1089-92. COSTOPOULOS, C., SUTARIA, N., ARIFF, B., FERTLEMAN, M., MALIK, I. & MIKHAIL, G. W. 2015. Balloon aortic valvuloplasty as a treatment option in the era of transcatheter aortic valve implantation. Expert Rev Cardiovasc Ther, 13, 457-60. CREAN, A. M., MAREDIA, N., BALLARD, G., MENEZES, R., WHARTON, G., FORSTER, J., GREENWOOD, J. P. & THOMSON, J. D. 2011. 3D Echo systematically underestimates right ventricular volumes compared to cardiovascular magnetic resonance in adult congenital heart disease patients with moderate or severe RV dilatation. J Cardiovasc Magn Reson, 13, 78. CRIBIER, A., ELTCHANINOFF, H., BASH, A., BORENSTEIN, N., TRON, C., BAUER, F., DERUMEAUX, G., ANSELME, F., LABORDE, F. & LEON, M. B. 2002. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation, 106, 3006-8. CROUCH, G., BENNETTS, J., SINHAL, A., TULLY, P. J., LEONG, D. P., BRADBROOK, C., PENHALL, A. L., DE PASQUALE, C. G., CHAKRABARTY, A., BAKER, R. A. & SELVANAYAGAM, J. B. 2015a. Early effects of transcatheter aortic valve implantation and aortic valve replacement on myocardial function and aortic valve hemodynamics: insights from cardiovascular magnetic resonance imaging. J Thorac Cardiovasc Surg, 149, 462-70. CROUCH, G., TULLY, P. J., BENNETTS, J., SINHAL, A., BRADBROOK, C., PENHALL, A. L., DE PASQUALE, C. G., BAKER, R. A. & SELVANAYAGAM, J. B. 2015b. Quantitative assessment of paravalvular regurgitation following transcatheter aortic valve replacement. J Cardiovasc Magn Reson, 17, 32. D'ONOFRIO, A., FACCHIN, M., BESOLA, L., MANZAN, E., TESSARI, C., BIZZOTTO, E., BIANCO, R., TARANTINI, G., NAPODANO, M., FRACCARO, C., BUJA, P., COVOLO, E., YZEIRAJ, E., PITTARELLO, D., ISABELLA, G., ILICETO, S. & GEROSA, G. 2015. Intermediate Clinical and Hemodynamic Outcomes After Transcatheter Aortic Valve Implantation. Ann Thorac Surg. DAHL, J. S., VIDEBAEK, L., POULSEN, M. K., RUDBAEK, T. R., PELLIKKA, P. A. & MOLLER, J. E. 2012. Global strain in severe aortic valve stenosis: relation to clinical outcome after aortic valve replacement. Circ Cardiovasc Imaging, 5, 613-20. DEBL, K., DJAVIDANI, B., BUCHNER, S., LIPKE, C., NITZ, W., FEUERBACH, S., RIEGGER, G. & LUCHNER, A. 2006. Delayed hyperenhancement in magnetic resonance imaging of left ventricular hypertrophy caused by aortic stenosis and hypertrophic cardiomyopathy: visualisation of focal fibrosis. Heart, 92, 1447-51. DELGADO, V., TOPS, L. F., VAN BOMMEL, R. J., VAN DER KLEY, F., MARSAN, N. A., KLAUTZ, R. J., VERSTEEGH, M. I., HOLMAN, E. R., SCHALIJ, M. J. & BAX, J. J. 2009. Strain analysis in patients with severe aortic stenosis and preserved left ventricular ejection fraction undergoing surgical valve replacement. Eur Heart J, 30, 3037-47. DEVOS, D. G., RIETZSCHEL, E., HEYSE, C., VANDEMAELE, P., VAN BORTEL, L., BABIN, D., SEGERS, P., WESTENBERG, J. M. & ACHTEN, R. 2015. MR pulse wave velocity increases with age faster in the thoracic aorta than in the abdominal aorta. J Magn Reson Imaging, 41, 765-72. DOBSON, L. E., FAIRBAIRN, T. A., PLEIN, S. & GREENWOOD, J. P. 2015. Sex Differences in Aortic Stenosis and Outcome Following Surgical and Transcatheter Aortic Valve Replacement. J Womens Health (Larchmt), 24, 986-95. DOGUI, A., KACHENOURA, N., FROUIN, F., LEFORT, M., DE CESARE, A., MOUSSEAUX, E. & HERMENT, A. 2011. Consistency of aortic distensibility and pulse wave velocity estimates with respect to the Bramwell-Hill theoretical model: a cardiovascular magnetic resonance study. J Cardiovasc Magn Reson, 13, 11. DWECK, M. R., JOSHI, S., MURIGU, T., ALPENDURADA, F., JABBOUR, A., MELINA, G., BANYA, W., GULATI, A., ROUSSIN, I., RAZA, S., PRASAD, N. A., WAGE, R., QUARTO, C., ANGELONI, E., REFICE, S., SHEPPARD, M., COOK, S. A., KILNER, P. J., PENNELL, D. J., NEWBY, D. E., MOHIADDIN, R. H., PEPPER, J. & PRASAD, S. K. 2011. Midwall fibrosis is an independent predictor of mortality in patients with aortic stenosis. J Am Coll Cardiol, 58, 1271-9. DYVERFELDT, P., BISSELL, M., BARKER, A. J., BOLGER, A. F., CARLHALL, C. J., EBBERS, T., FRANCIOS, C. J., FRYDRYCHOWICZ, A., GEIGER, J., GIESE, D., HOPE, M. D., KILNER, P. J., KOZERKE, S., MYERSON, S., NEUBAUER, S., WIEBEN, O. & MARKL, M. 2015. 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson, 17, 72. DYVERFELDT, P., GARDHAGEN, R., SIGFRIDSSON, A., KARLSSON, M. & EBBERS, T. 2009. On MRI turbulence quantification. Magn Reson Imaging, 27, 913-22. EVANGELISTA, A., FLACHSKAMPF, F. A., ERBEL, R., ANTONINI-CANTERIN, F., VLACHOPOULOS, C., ROCCHI, G., SICARI, R., NIHOYANNOPOULOS, P., ZAMORANO, J., PEPI, M., BREITHARDT, O. A. & PLONSKA-GOSCINIAK, E. 2010. Echocardiography in aortic diseases: EAE recommendations for clinical practice. Eur J Echocardiogr, 11, 645-58. EVEBORN, G. W., SCHIRMER, H., HEGGELUND, G., LUNDE, P. & RASMUSSEN, K. 2013. The evolving epidemiology of valvular aortic stenosis. the Tromso study. Heart, 99, 396-400. EWE, S. H., MURATORI, M., VAN DER KLEY, F., PEPI, M., DELGADO, V., TAMBORINI, G., FUSINI, L., DE WEGER, A., GRIPARI, P., BARTORELLI, A., BAX, J. J. & MARSAN, N. A. 2015. Effect of aortic regurgitation following transcatheter aortic valve implantation on outcomes. Am J Cardiol, 115, 664-9. FAIRBAIRN, T. A., MEADS, D. M., HULME, C., MATHER, A. N., PLEIN, S., BLACKMAN, D. J. & GREENWOOD, J. P. 2013a. The cost-effectiveness of transcatheter aortic valve implantation versus surgical aortic valve replacement in patients with severe aortic stenosis at high operative risk. Heart, 99, 914-20. FAIRBAIRN, T. A., MEADS, D. M., MATHER, A. N., MOTWANI, M., PAVITT, S., PLEIN, S., BLACKMAN, D. J. & GREENWOOD, J. P. 2012. Serial change in health-related quality of life over 1 year after transcatheter aortic valve implantation: predictors of health outcomes. J Am Coll Cardiol, 59, 1672-80. FAIRBAIRN, T. A., STEADMAN, C. D., MATHER, A. N., MOTWANI, M., BLACKMAN, D. J., PLEIN, S., MCCANN, G. P. & GREENWOOD, J. P. 2013b. Assessment of valve haemodynamics, reverse ventricular remodelling and myocardial fibrosis following transcatheter aortic valve implantation compared to surgical aortic valve replacement: a cardiovascular magnetic resonance study. Heart, 99, 1185-91. FLETT, A. S., HASLETON, J., COOK, C., HAUSENLOY, D., QUARTA, G., ARITI, C., MUTHURANGU, V. & MOON, J. C. 2011. Evaluation of techniques for the quantification of myocardial scar of differing etiology using cardiac magnetic resonance. JACC Cardiovasc Imaging, 4, 150-6. FLETT, A. S., HAYWARD, M. P., ASHWORTH, M. T., HANSEN, M. S., TAYLOR, A. M., ELLIOTT, P. M., MCGREGOR, C. & MOON, J. C. 2010. Equilibrium contrast cardiovascular magnetic resonance for the measurement of diffuse myocardial fibrosis: preliminary validation in humans. Circulation, 122, 138-44. FORSBERG, L. M., TAMAS, E., VANKY, F., NIELSEN, N. E., ENGVALL, J. & NYLANDER, E. 2011. Left and right ventricular function in aortic stenosis patients 8 weeks post-transcatheter aortic valve implantation or surgical aortic valve replacement. Eur J Echocardiogr, 12, 603-11. GAASCH, W. H. & ZILE, M. R. 2011. Left ventricular structural remodeling in health and disease: with special emphasis on volume, mass, and geometry. J Am Coll Cardiol, 58, 1733-40. GALLI, E., LANCELLOTTI, P., SENGUPTA, P. P. & DONAL, E. 2014. LV mechanics in mitral and aortic valve diseases: value of functional assessment beyond ejection fraction. JACC Cardiovasc Imaging, 7, 1151-66. GARCIA, D., CAMICI, P. G., DURAND, L. G., RAJAPPAN, K., GAILLARD, E., RIMOLDI, O. E. & PIBAROT, P. 2009. Impairment of coronary flow reserve in aortic stenosis. J Appl Physiol (1985), 106, 113-21. GATEHOUSE, P. D., KEEGAN, J., CROWE, L. A., MASOOD, S., MOHIADDIN, R. H., KREITNER, K. F. & FIRMIN, D. N. 2005. Applications of phase-contrast flow and velocity imaging in cardiovascular MRI. Eur Radiol, 15, 2172-84. GELFAND, E. V., HUGHES, S., HAUSER, T. H., YEON, S. B., GOEPFERT, L., KISSINGER, K. V., ROFSKY, N. M. & MANNING, W. J. 2006. Severity of mitral and aortic regurgitation as assessed by cardiovascular magnetic resonance: optimizing correlation with Doppler echocardiography. J Cardiovasc Magn Reson, 8, 503-7. GIBBONS, R. J., VALETI, U. S., ARAOZ, P. A. & JAFFE, A. S. 2004. The quantification of infarct size. J Am Coll Cardiol, 44, 1533-42. GOLDBERG, I. J., TRENT, C. M. & SCHULZE, P. C. 2012. Lipid metabolism and toxicity in the heart. Cell Metab, 15, 805-12. GOLDSTEIN, J. A., TWEDDELL, J. S., BARZILAI, B., YAGI, Y., JAFFE, A. S. & COX, J. L. 1991. Right atrial ischemia exacerbates hemodynamic compromise associated with experimental right ventricular dysfunction. J Am Coll Cardiol, 18, 1564-72. GOOLEY, R., LOCKWOOD, S., ANTONIS, P. & MEREDITH, I. T. 2013. The SADRA Lotus Valve System: a fully repositionable, retrievable prosthesis. Minerva Cardioangiol, 61, 45-52. GOOLEY, R. P., TALMAN, A. H., CAMERON, J. D., LOCKWOOD, S. M. & MEREDITH, I. T. 2015. Comparison of Self-Expanding and Mechanically Expanded Transcatheter Aortic Valve Prostheses. JACC Cardiovasc Interv, 8, 962-71. GRABSKAYA, E., BECKER, M., ALTIOK, E., DOHMEN, G., BREHMER, K., HAMADA-LANGER, S., KENNES, L., MARX, N. & HOFFMANN, R. 2011. Impact of transcutaneous aortic valve implantation on myocardial deformation. Echocardiography, 28, 397-401. GROTENHUIS, H. B., OTTENKAMP, J., WESTENBERG, J. J., BAX, J. J., KROFT, L. J. & DE ROOS, A. 2007. Reduced aortic elasticity and dilatation are associated with aortic regurgitation and left ventricular hypertrophy in nonstenotic bicuspid aortic valve patients. J Am Coll Cardiol, 49, 1660-5. GROTHUES, F., MOON, J. C., BELLENGER, N. G., SMITH, G. S., KLEIN, H. U. & PENNELL, D. J. 2004. Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance. Am Heart J, 147, 218-23. GROTHUES, F., SMITH, G. C., MOON, J. C., BELLENGER, N. G., COLLINS, P., KLEIN, H. U. & PENNELL, D. J. 2002. Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol, 90, 29-34. GULATI, A., ISMAIL, T. F., JABBOUR, A., ISMAIL, N. A., MORARJI, K., ALI, A., RAZA, S., KHWAJA, J., BROWN, T. D., LIODAKIS, E., BAKSI, A. J., SHAKUR, R., GUHA, K., ROUGHTON, M., WAGE, R., COOK, S. A., ALPENDURADA, F., ASSOMULL, R. G., MOHIADDIN, R. H., COWIE, M. R., PENNELL, D. J. & PRASAD, S. K. 2013. Clinical utility and prognostic value of left atrial volume assessment by cardiovascular magnetic resonance in non-ischaemic dilated cardiomyopathy. Eur J Heart Fail, 15, 660-70. HACHICHA, Z., DUMESNIL, J. G., BOGATY, P. & PIBAROT, P. 2007. Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival. Circulation, 115, 2856-64. HACHICHA, Z., DUMESNIL, J. G. & PIBAROT, P. 2009. Usefulness of the valvuloarterial impedance to predict adverse outcome in asymptomatic aortic stenosis. J Am Coll Cardiol, 54, 1003-11. HAMM, C. W., ARSALAN, M. & MACK, M. J. 2016. The future of transcatheter aortic valve implantation. Eur Heart J, 37, 803-10. HARTLAGE, G. R., BABALIAROS, V. C., THOURANI, V. H., HAYEK, S., CHRYSOHOOU, C., GHASEMZADEH, N., STILLMAN, A. E., CLEMENTS, S. D., OSHINSKI, J. N. & LERAKIS, S. 2014. The role of cardiovascular magnetic resonance in stratifying paravalvular leak severity after transcatheter aortic valve replacement: an observational outcome study. J Cardiovasc Magn Reson, 16, 93. HEIN, S., ARNON, E., KOSTIN, S., SCHONBURG, M., ELSASSER, A., POLYAKOVA, V., BAUER, E. P., KLOVEKORN, W. P. & SCHAPER, J. 2003. Progression from compensated hypertrophy to failure in the pressure-overloaded human heart: structural deterioration and compensatory mechanisms. Circulation, 107, 984-91. HONKONEN, E. L., KAUKINEN, L., PEHKONEN, E. J. & KAUKINEN, S. 1997. Myocardial cooling and right ventricular function in patients with right coronary artery disease: antegrade vs. retrograde cardioplegia. Acta Anaesthesiol Scand, 41, 287-96. HUBER, A., SOURBRON, S., KLAUSS, V., SCHAEFER, J., BAUNER, K. U., SCHWEYER, M., REISER, M., RUMMENY, E. & RIEBER, J. 2012. Magnetic resonance perfusion of the myocardium: semiquantitative and quantitative evaluation in comparison with coronary angiography and fractional flow reserve. Invest Radiol, 47, 332-8. HUFNAGEL, C. A. & HARVEY, W. P. 1953. The surgical correction of aortic regurgitation preliminary report. Bull Georgetown Univ Med Cent, 6, 60-1. IBRAHIM EL, S. H., JOHNSON, K. R., MILLER, A. B., SHAFFER, J. M. & WHITE, R. D. 2010. Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques. J Cardiovasc Magn Reson, 12, 26. IUNG, B., BARON, G., TORNOS, P., GOHLKE-BARWOLF, C., BUTCHART, E. G. & VAHANIAN, A. 2007. Valvular heart disease in the community: a European experience. Curr Probl Cardiol, 32, 609-61. IUNG, B., CACHIER, A., BARON, G., MESSIKA-ZEITOUN, D., DELAHAYE, F., TORNOS, P., GOHLKE-BARWOLF, C., BOERSMA, E., RAVAUD, P. & VAHANIAN, A. 2005. Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J, 26, 2714-20. IUNG, B. & VAHANIAN, A. 2012. Degenerative calcific aortic stenosis: a natural history. Heart, 98 Suppl 4, iv7-13. IUNG, B. & VAHANIAN, A. 2014. Epidemiology of acquired valvular heart disease. Can J Cardiol, 30, 962-70. IWAHASHI, N., NAKATANI, S., KANZAKI, H., HASEGAWA, T., ABE, H. & KITAKAZE, M. 2006. Acute improvement in myocardial function assessed by myocardial strain and strain rate after aortic valve replacement for aortic stenosis. J Am Soc Echocardiogr, 19, 1238-44. JOINT TASK FORCE ON THE MANAGEMENT OF VALVULAR HEART DISEASE OF THE EUROPEAN SOCIETY OF, C., EUROPEAN ASSOCIATION FOR CARDIO-THORACIC, S., VAHANIAN, A., ALFIERI, O., ANDREOTTI, F., ANTUNES, M. J., BARON-ESQUIVIAS, G., BAUMGARTNER, H., BORGER, M. A., CARREL, T. P., DE BONIS, M., EVANGELISTA, A., FALK, V., IUNG, B., LANCELLOTTI, P., PIERARD, L., PRICE, S., SCHAFERS, H. J., SCHULER, G., STEPINSKA, J., SWEDBERG, K., TAKKENBERG, J., VON OPPELL, U. O., WINDECKER, S., ZAMORANO, J. L. & ZEMBALA, M. 2012. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J, 33, 2451-96. JULIUS, B. K., SPILLMANN, M., VASSALLI, G., VILLARI, B., EBERLI, F. R. & HESS, O. M. 1997. Angina pectoris in patients with aortic stenosis and normal coronary arteries. Mechanisms and pathophysiological concepts. Circulation, 95, 892-8. KADEN, J. J., DEMPFLE, C. E., GROBHOLZ, R., TRAN, H. T., KILIC, R., SARIKOC, A., BRUECKMANN, M., VAHL, C., HAGL, S., HAASE, K. K. & BORGGREFE, M. 2003. Interleukin-1 beta promotes matrix metalloproteinase expression and cell proliferation in calcific aortic valve stenosis. Atherosclerosis, 170, 205-11. KAHLERT, P., PAROHL, N., ALBERT, J., SCHAFER, L., REINHARDT, R., KAISER, G. M., MCDOUGALL, I., DECKER, B., PLICHT, B., ERBEL, R., EGGEBRECHT, H., LADD, M. E. & QUICK, H. H. 2012. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine. J Cardiovasc Magn Reson, 14, 21. KAKU, K., TAKEUCHI, M., TSANG, W., TAKIGIKU, K., YASUKOCHI, S., PATEL, A. R., MOR-AVI, V., LANG, R. M. & OTSUJI, Y. 2014. Age-related normal range of left ventricular strain and torsion using three-dimensional speckle-tracking echocardiography. J Am Soc Echocardiogr, 27, 55-64. KAMMERLANDER, A. A., MARZLUF, B. A., GRAF, A., BACHMANN, A., KOCHER, A., BONDERMAN, D. & MASCHERBAUER, J. 2014. Right ventricular dysfunction, but not tricuspid regurgitation, is associated with outcome late after left heart valve procedure. J Am Coll Cardiol, 64, 2633-42. KAPADIA, S. R., LEON, M. B., MAKKAR, R. R., TUZCU, E. M., SVENSSON, L. G., KODALI, S., WEBB, J. G., MACK, M. J., DOUGLAS, P. S., THOURANI, V. H., BABALIAROS, V. C., HERRMANN, H. C., SZETO, W. Y., PICHARD, A. D., WILLIAMS, M. R., FONTANA, G. P., MILLER, D. C., ANDERSON, W. N., AKIN, J. J., DAVIDSON, M. J. & SMITH, C. R. 2015. 5-year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial. Lancet, 385, 2485-91. KAPPETEIN, A. P., HEAD, S. J., GENEREUX, P., PIAZZA, N., VAN MIEGHEM, N. M., BLACKSTONE, E. H., BROTT, T. G., COHEN, D. J., CUTLIP, D. E., VAN ES, G. A., HAHN, R. T., KIRTANE, A. J., KRUCOFF, M. W., KODALI, S., MACK, M. J., MEHRAN, R., RODES-CABAU, J., VRANCKX, P., WEBB, J. G., WINDECKER, S., SERRUYS, P. W. & LEON, M. B. 2013. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Thorac Cardiovasc Surg, 145, 6-23. KEMPNY, A., DILLER, G. P., KALESCHKE, G., ORWAT, S., FUNKE, A., SCHMIDT, R., KERCKHOFF, G., GHEZELBASH, F., RUKOSUJEW, A., REINECKE, H., SCHELD, H. H. & BAUMGARTNER, H. 2012. Impact of transcatheter aortic valve implantation or surgical aortic valve replacement on right ventricular function. Heart, 98, 1299-304. KEYL, C., SCHNEIDER, J., BEYERSDORF, F., RUILE, P., SIEPE, M., PIOCH, K., SCHNEIDER, R. & JANDER, N. 2015. Right ventricular function after aortic valve replacement: a pilot study comparing surgical and transcatheter procedures using 3D echocardiography. Eur J Cardiothorac Surg. KIM, W. K., ROLF, A., LIEBETRAU, C., VAN LINDEN, A., BLUMENSTEIN, J., KEMPFERT, J., BACHMANN, G., NEF, H., HAMM, C., WALTHER, T. & MOLLMANN, H. 2014. Detection of myocardial injury by CMR after transcatheter aortic valve replacement. J Am Coll Cardiol, 64, 349-57. KOCH, J. A., POLL, L. W., GODEHARDT, E., KORBMACHER, B. & MODDER, U. 2000. Right and left ventricular volume measurements in an animal heart model in vitro: first experiences with cardiac MRI at 1.0 T. Eur Radiol, 10, 455-8. KODALI, S., PIBAROT, P., DOUGLAS, P. S., WILLIAMS, M., XU, K., THOURANI, V., RIHAL, C. S., ZAJARIAS, A., DOSHI, D., DAVIDSON, M., TUZCU, E. M., STEWART, W., WEISSMAN, N. J., SVENSSON, L., GREASON, K., MANIAR, H., MACK, M., ANWARUDDIN, S., LEON, M. B. & HAHN, R. T. 2015. Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes. Eur Heart J, 36, 449-56. KODALI, S. K., WILLIAMS, M. R., SMITH, C. R., SVENSSON, L. G., WEBB, J. G., MAKKAR, R. R., FONTANA, G. P., DEWEY, T. M., THOURANI, V. H., PICHARD, A. D., FISCHBEIN, M., SZETO, W. Y., LIM, S., GREASON, K. L., TEIRSTEIN, P. S., MALAISRIE, S. C., DOUGLAS, P. S., HAHN, R. T., WHISENANT, B., ZAJARIAS, A., WANG, D., AKIN, J. J., ANDERSON, W. N., LEON, M. B. & INVESTIGATORS, P. T. 2012. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med, 366, 1686-95. KOUCHOUKOS, N. T., LELL, W. A., KARP, R. B. & SAMUELSON, P. N. 1979. Hemodynamic effects of aortic clamping and decompression with a temporary shunt for resection of the descending thoracic aorta. Surgery, 85, 25-30. KRAYENBUEHL, H. P., HESS, O. M., MONRAD, E. S., SCHNEIDER, J., MALL, G. & TURINA, M. 1989. Left ventricular myocardial structure in aortic valve disease before, intermediate, and late after aortic valve replacement. Circulation, 79, 744-55. KUSUNOSE, K., GOODMAN, A., PARIKH, R., BARR, T., AGARWAL, S., POPOVIC, Z. B., GRIMM, R. A., GRIFFIN, B. P. & DESAI, M. Y. 2014. Incremental prognostic value of left ventricular global longitudinal strain in patients with aortic stenosis and preserved ejection fraction. Circ Cardiovasc Imaging, 7, 938-45. KWAK, Y. L., OH, Y. J., JUNG, S. M., YOO, K. J., LEE, J. H. & HONG, Y. W. 2004. Change in right ventricular function during off-pump coronary artery bypass graft surgery. Eur J Cardiothorac Surg, 25, 572-7. LA MANNA, A., SANFILIPPO, A., CAPODANNO, D., SALEMI, A., CADONI, A., CASCONE, I., POLIZZI, G., FIGUERA, M., PITTALA, R., PRIVITERA, C. & TAMBURINO, C. 2013. Left ventricular reverse remodeling after transcatheter aortic valve implantation: a cardiovascular magnetic resonance study. J Cardiovasc Magn Reson, 15, 39. LANCELLOTTI, P., DONAL, E., MAGNE, J., O'CONNOR, K., MOONEN, M. L., COSYNS, B. & PIERARD, L. A. 2010. Impact of global left ventricular afterload on left ventricular function in asymptomatic severe aortic stenosis: a two-dimensional speckle-tracking study. Eur J Echocardiogr, 11, 537-43. LEON, M. B., PIAZZA, N., NIKOLSKY, E., BLACKSTONE, E. H., CUTLIP, D. E., KAPPETEIN, A. P., KRUCOFF, M. W., MACK, M., MEHRAN, R., MILLER, C., MOREL, M. A., PETERSEN, J., POPMA, J. J., TAKKENBERG, J. J., VAHANIAN, A., VAN ES, G. A., VRANCKX, P., WEBB, J. G., WINDECKER, S. & SERRUYS, P. W. 2011. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium. Eur Heart J, 32, 205-17. LEON, M. B., SMITH, C. R., MACK, M., MILLER, D. C., MOSES, J. W., SVENSSON, L. G., TUZCU, E. M., WEBB, J. G., FONTANA, G. P., MAKKAR, R. R., BROWN, D. L., BLOCK, P. C., GUYTON, R. A., PICHARD, A. D., BAVARIA, J. E., HERRMANN, H. C., DOUGLAS, P. S., PETERSEN, J. L., AKIN, J. J., ANDERSON, W. N., WANG, D., POCOCK, S. & INVESTIGATORS, P. T. 2010. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med, 363, 1597-607. LEON, M. B., SMITH, C. R., MACK, M. J., MAKKAR, R. R., SVENSSON, L. G., KODALI, S. K., THOURANI, V. H., TUZCU, E. M., MILLER, D. C., HERRMANN, H. C., DOSHI, D., COHEN, D. J., PICHARD, A. D., KAPADIA, S., DEWEY, T., BABALIAROS, V., SZETO, W. Y., WILLIAMS, M. R., KEREIAKES, D., ZAJARIAS, A., GREASON, K. L., WHISENANT, B. K., HODSON, R. W., MOSES, J. W., TRENTO, A., BROWN, D. L., FEARON, W. F., PIBAROT, P., HAHN, R. T., JABER, W. A., ANDERSON, W. N., ALU, M. C. & WEBB, J. G. 2016. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. LERAKIS, S., HAYEK, S. S. & DOUGLAS, P. S. 2013. Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge. Circulation, 127, 397-407. LIAKOPOULOS, O. J., KUHN, E. W., CHOI, Y. H., CHANG, W., WITTWER, T., MADERSHAHIAN, N., WASSMER, G. & WAHLERS, T. 2010. Myocardial protection in cardiac surgery patients requiring prolonged aortic cross-clamp times: a single-center evaluation of clinical outcomes comparing two blood cardioplegic strategies. J Cardiovasc Surg (Torino), 51, 895-905. LINDMAN, B. R., STEWART, W. J., PIBAROT, P., HAHN, R. T., OTTO, C. M., XU, K., DEVEREUX, R. B., WEISSMAN, N. J., ENRIQUEZ-SARANO, M., SZETO, W. Y., MAKKAR, R., MILLER, D. C., LERAKIS, S., KAPADIA, S., BOWERS, B., GREASON, K. L., MCANDREW, T. C., LEI, Y., LEON, M. B. & DOUGLAS, P. S. 2014. Early regression of severe left ventricular hypertrophy after transcatheter aortic valve replacement is associated with decreased hospitalizations. JACC Cardiovasc Interv, 7, 662-73. LINDQVIST, P., ZHAO, Y., BAJRAKTARI, G., HOLMGREN, A. & HENEIN, M. Y. 2011. Aortic valve replacement normalizes left ventricular twist function. Interact Cardiovasc Thorac Surg, 12, 701-6. LINKE, A., WENAWESER, P., GERCKENS, U., TAMBURINO, C., BOSMANS, J., BLEIZIFFER, S., BLACKMAN, D., SCHAFER, U., MULLER, R., SIEVERT, H., SONDERGAARD, L., KLUGMANN, S., HOFFMANN, R., TCHETCHE, D., COLOMBO, A., LEGRAND, V. M., BEDOGNI, F., LEPRINCE, P., SCHULER, G., MAZZITELLI, D., EFTYCHIOU, C., FRERKER, C., BOEKSTEGERS, P., WINDECKER, S., MOHR, F. W., WOITEK, F., LANGE, R., BAUERNSCHMITT, R., BRECKER, S. & INVESTIGATORS, A. S. 2014. Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study. Eur Heart J, 35, 2672-84. LOPEZ-MATTEI, J. C. & SHAH, D. J. 2013. The role of cardiac magnetic resonance in valvular heart disease. Methodist Debakey Cardiovasc J, 9, 142-8. MACK, M. J., LEON, M. B., SMITH, C. R., MILLER, D. C., MOSES, J. W., TUZCU, E. M., WEBB, J. G., DOUGLAS, P. S., ANDERSON, W. N., BLACKSTONE, E. H., KODALI, S. K., MAKKAR, R. R., FONTANA, G. P., KAPADIA, S., BAVARIA, J., HAHN, R. T., THOURANI, V. H., BABALIAROS, V., PICHARD, A., HERRMANN, H. C., BROWN, D. L., WILLIAMS, M., AKIN, J., DAVIDSON, M. J. & SVENSSON, L. G. 2015. 5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial. Lancet, 385, 2477-84. MAHADEVIA, R., BARKER, A. J., SCHNELL, S., ENTEZARI, P., KANSAL, P., FEDAK, P. W., MALAISRIE, S. C., MCCARTHY, P., COLLINS, J., CARR, J. & MARKL, M. 2014. Bicuspid aortic cusp fusion morphology alters aortic three-dimensional outflow patterns, wall shear stress, and expression of aortopathy. Circulation, 129, 673-82. MAHMOD, M., BULL, S., SUTTIE, J. J., PAL, N., HOLLOWAY, C., DASS, S., MYERSON, S. G., SCHNEIDER, J. E., DE SILVA, R., PETROU, M., SAYEED, R., WESTABY, S., CLELLAND, C., FRANCIS, J. M., ASHRAFIAN, H., KARAMITSOS, T. D. & NEUBAUER, S. 2013. Myocardial steatosis and left ventricular contractile dysfunction in patients with severe aortic stenosis. Circ Cardiovasc Imaging, 6, 808-16. MAHRHOLDT, H., WAGNER, A., JUDD, R. M., SECHTEM, U. & KIM, R. J. 2005. Delayed enhancement cardiovascular magnetic resonance assessment of non-ischaemic cardiomyopathies. Eur Heart J, 26, 1461-74. MARKL, M., CHAN, F. P., ALLEY, M. T., WEDDING, K. L., DRANEY, M. T., ELKINS, C. J., PARKER, D. W., WICKER, R., TAYLOR, C. A., HERFKENS, R. J. & PELC, N. J. 2003. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging, 17, 499-506. MARKL, M., WALLIS, W. & HARLOFF, A. 2011. Reproducibility of flow and wall shear stress analysis using flow-sensitive four-dimensional MRI. J Magn Reson Imaging, 33, 988-94. MAROULES, C. D., KHERA, A., AYERS, C., GOEL, A., PESHOCK, R. M., ABBARA, S. & KING, K. S. 2014. Cardiovascular outcome associations among cardiovascular magnetic resonance measures of arterial stiffness: the Dallas heart study. J Cardiovasc Magn Reson, 16, 33. MCGAVOCK, J. M., VICTOR, R. G., UNGER, R. H., SZCZEPANIAK, L. S., AMERICAN COLLEGE OF, P. & THE AMERICAN PHYSIOLOGICAL, S. 2006. Adiposity of the heart, revisited. Ann Intern Med, 144, 517-24. MEIMOUN, P., ELMKIES, F., BENALI, T., BOULANGER, J., ZEMIR, H., CLERC, J. & LUYCX-BORE, A. 2011. [Assessment of left ventricular twist mechanics by two-dimensional strain in severe aortic stenosis with preserved ejection fraction]. Ann Cardiol Angeiol (Paris), 60, 259-66. MELINA, G., RAJAPPAN, K., AMRANI, M., KHAGHANI, A., PENNELL, D. J. & YACOUB, M. H. 2002. Aortic distensibility after aortic root replacement assessed with cardiovascular magnetic resonance. J Heart Valve Dis, 11, 67-74; discussion 74. MEREDITH AM, I. T., WALTERS, D. L., DUMONTEIL, N., WORTHLEY, S. G., TCHETCHE, D., MANOHARAN, G., BLACKMAN, D. J., RIOUFOL, G., HILDICK-SMITH, D., WHITBOURN, R. J., LEFEVRE, T., LANGE, R., MULLER, R., REDWOOD, S., ALLOCCO, D. J. & DAWKINS, K. D. 2014. Transcatheter aortic valve replacement for severe symptomatic aortic stenosis using a repositionable valve system: 30-day primary endpoint results from the REPRISE II study. J Am Coll Cardiol, 64, 1339-48. MEREDITH, I. T., HOOD, K. L., HARATANI, N., ALLOCCO, D. J. & DAWKINS, K. D. 2012. Boston Scientific Lotus valve. EuroIntervention, 8 Suppl Q, Q70-4. MEREDITH, I. T., WORTHLEY, S. G., WHITBOURN, R. J., ANTONIS, P., MONTARELLO, J. K., NEWCOMB, A. E., LOCKWOOD, S., HARATANI, N., ALLOCCO, D. J. & DAWKINS, K. D. 2014. Transfemoral aortic valve replacement with the repositionable Lotus Valve System in high surgical risk patients: the REPRISE I study. EuroIntervention, 9, 1264-70. MERTEN, C., BEURICH, H. W., ZACHOW, D., MOSTAFA, A. E., GEIST, V., TOELG, R., RICHARDT, G. & ABDEL-WAHAB, M. 2013. Aortic regurgitation and left ventricular remodeling after transcatheter aortic valve implantation: a serial cardiac magnetic resonance imaging study. Circ Cardiovasc Interv, 6, 476-83. METAFRATZI, Z. M., EFREMIDIS, S. C., SKOPELITOU, A. S. & DE ROOS, A. 2002. The clinical significance of aortic compliance and its assessment with magnetic resonance imaging. J Cardiovasc Magn Reson, 4, 481-91. MEWTON, N., LIU, C. Y., CROISILLE, P., BLUEMKE, D. & LIMA, J. A. 2011. Assessment of myocardial fibrosis with cardiovascular magnetic resonance. J Am Coll Cardiol, 57, 891-903. MEYER, C. G., FRICK, M., LOTFI, S., ALTIOK, E., KOOS, R., KIRSCHFINK, A., LEHRKE, M., AUTSCHBACH, R. & HOFFMANN, R. 2014. Regional left ventricular function after transapical vs. transfemoral transcatheter aortic valve implantation analysed by cardiac magnetic resonance feature tracking. Eur Heart J Cardiovasc Imaging, 15, 1168-76. MILANO, A. D., FAGGIAN, G., DODONOV, M., GOLIA, G., TOMEZZOLI, A., BORTOLOTTI, U. & MAZZUCCO, A. 2012. Prognostic value of myocardial fibrosis in patients with severe aortic valve stenosis. J Thorac Cardiovasc Surg, 144, 830-7. MILLER, J. G., LI, M., MAZILU, D., HUNT, T. & HORVATH, K. A. 2015. Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement. J Thorac Cardiovasc Surg. MOAT, N. E., LUDMAN, P., DE BELDER, M. A., BRIDGEWATER, B., CUNNINGHAM, A. D., YOUNG, C. P., THOMAS, M., KOVAC, J., SPYT, T., MACCARTHY, P. A., WENDLER, O., HILDICK-SMITH, D., DAVIES, S. W., TRIVEDI, U., BLACKMAN, D. J., LEVY, R. D., BRECKER, S. J., BAUMBACH, A., DANIEL, T., GRAY, H. & MULLEN, M. J. 2011. Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry. J Am Coll Cardiol, 58, 2130-8. MONIN, J. L., QUERE, J. P., MONCHI, M., PETIT, H., BALEYNAUD, S., CHAUVEL, C., POP, C., OHLMANN, P., LELGUEN, C., DEHANT, P., TRIBOUILLOY, C. & GUERET, P. 2003. Low-gradient aortic stenosis: operative risk stratification and predictors for long-term outcome: a multicenter study using dobutamine stress hemodynamics. Circulation, 108, 319-24. MURRAY, G. 1956. Homologous aortic-valve-segment transplants as surgical treatment for aortic and mitral insufficiency. Angiology, 7, 466-71. MYERSON, S. G. 2012. Heart valve disease: investigation by cardiovascular magnetic resonance. J Cardiovasc Magn Reson, 14, 7. MYERSON, S. G., BELLENGER, N. G. & PENNELL, D. J. 2002a. Assessment of left ventricular mass by cardiovascular magnetic resonance. Hypertension, 39, 750-5. MYERSON, S. G., MONTGOMERY, H. E., WORLD, M. J. & PENNELL, D. J. 2002b. Left ventricular mass: reliability of M-mode and 2-dimensional echocardiographic formulas. Hypertension, 40, 673-8. NAGEL, E., STUBER, M., BURKHARD, B., FISCHER, S. E., SCHEIDEGGER, M. B., BOESIGER, P. & HESS, O. M. 2000. Cardiac rotation and relaxation in patients with aortic valve stenosis. Eur Heart J, 21, 582-9. NELSON, A. J., WORTHLEY, S. G., CAMERON, J. D., WILLOUGHBY, S. R., PIANTADOSI, C., CARBONE, A., DUNDON, B. K., LEUNG, M. C., HOPE, S. A., MEREDITH, I. T. & WORTHLEY, M. I. 2009. Cardiovascular magnetic resonance-derived aortic distensibility: validation and observed regional differences in the elderly. J Hypertens, 27, 535-42. NEMES, A., GALEMA, T. W., GELEIJNSE, M. L., SOLIMAN, O. I., YAP, S. C., ANWAR, A. M. & TEN CATE, F. J. 2007. Aortic valve replacement for aortic stenosis is associated with improved aortic distensibility at long-term follow-up. Am Heart J, 153, 147-51. NEMES, A., GALEMA, T. W., SOLIMAN, O. I., BOGERS, A. J., TEN CATE, F. J. & GELEIJNSE, M. L. 2009. Improved aortic distensibility after aortic homograft root replacement at long-term follow-up. Int J Cardiol, 136, 216-9. NEWTON, J. D., REDWOOD, S. & PRENDERGAST, B. D. 2015. Transcatheter aortic valve implantation: a durable treatment option in aortic stenosis? Heart, 101, 913-4. NG, A. C., DELGADO, V., BERTINI, M., VAN DER MEER, R. W., RIJZEWIJK, L. J., HOOI EWE, S., SIEBELINK, H. M., SMIT, J. W., DIAMANT, M., ROMIJN, J. A., DE ROOS, A., LEUNG, D. Y., LAMB, H. J. & BAX, J. J. 2010. Myocardial steatosis and biventricular strain and strain rate imaging in patients with type 2 diabetes mellitus. Circulation, 122, 2538-44. NIGRI, M., AZEVEDO, C. F., ROCHITTE, C. E., SCHRAIBMAN, V., TARASOUTCHI, F., POMMERANTZEFF, P. M., BRANDAO, C. M., SAMPAIO, R. O., PARGA, J. R., AVILA, L. F., SPINA, G. S. & GRINBERG, M. 2009. Contrast-enhanced magnetic resonance imaging identifies focal regions of intramyocardial fibrosis in patients with severe aortic valve disease: Correlation with quantitative histopathology. Am Heart J, 157, 361-8. NIJVELDT, R., GERMANS, T., MCCANN, G. P., BEEK, A. M. & VAN ROSSUM, A. C. 2008. Semi-quantitative assessment of right ventricular function in comparison to a 3D volumetric approach: a cardiovascular magnetic resonance study. Eur Radiol, 18, 2399-405. NISHIMURA, R. A., OTTO, C. M., BONOW, R. O., CARABELLO, B. A., ERWIN, J. P., 3RD, GUYTON, R. A., O'GARA, P. T., RUIZ, C. E., SKUBAS, N. J., SORAJJA, P., SUNDT, T. M., 3RD & THOMAS, J. D. 2014a. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol, 63, 2438-88. NISHIMURA, R. A., OTTO, C. M., BONOW, R. O., CARABELLO, B. A., ERWIN, J. P., 3RD, GUYTON, R. A., O'GARA, P. T., RUIZ, C. E., SKUBAS, N. J., SORAJJA, P., SUNDT, T. M., 3RD, THOMAS, J. D. & AMERICAN COLLEGE OF CARDIOLOGY/AMERICAN HEART ASSOCIATION TASK FORCE ON PRACTICE, G. 2014b. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol, 63, 2438-88. NKOMO, V. T., GARDIN, J. M., SKELTON, T. N., GOTTDIENER, J. S., SCOTT, C. G. & ENRIQUEZ-SARANO, M. 2006. Burden of valvular heart diseases: a population-based study. Lancet, 368, 1005-11. NWAEJIKE, N., MILLS, K., STABLES, R. & FIELD, M. 2015. Balloon aortic valvuloplasty as a bridge to aortic valve surgery for severe aortic stenosis. Interact Cardiovasc Thorac Surg, 20, 429-35. O'BRIEN, K. R., COWAN, B. R., JAIN, M., STEWART, R. A., KERR, A. J. & YOUNG, A. A. 2008. MRI phase contrast velocity and flow errors in turbulent stenotic jets. J Magn Reson Imaging, 28, 210-8. OH, J. K., LITTLE, S. H., ABDELMONEIM, S. S., REARDON, M. J., KLEIMAN, N. S., LIN, G., BACH, D., GILLAM, L., KAR, B., COSELLI, J., SENGUPTA, P. P., GREWAL, K., CHANG, J., CHANG, Y., BOULWARE, M., ADAMS, D. H., POPMA, J. J. & COREVALVE, U. S. P. T. C. I. 2015. Regression of Paravalvular Aortic Regurgitation and Remodeling of Self-Expanding Transcatheter Aortic Valve: An Observation From the CoreValve U.S. Pivotal Trial. JACC Cardiovasc Imaging, 8, 1364-75. OKADA, D. R., RAHMOUNI, H. W., HERRMANN, H. C., BAVARIA, J. E., FORFIA, P. R. & HAN, Y. 2014. Assessment of right ventricular function by transthoracic echocardiography following aortic valve replacement. Echocardiography, 31, 552-7. OLIVER, J. J. & WEBB, D. J. 2003. Noninvasive assessment of arterial stiffness and risk of atherosclerotic events. Arterioscler Thromb Vasc Biol, 23, 554-66. OZKAN, A., KAPADIA, S., TUZCU, M. & MARWICK, T. H. 2011. Assessment of left ventricular function in aortic stenosis. Nat Rev Cardiol, 8, 494-501. PAELINCK, B. P., VAN HERCK, P. L., RODRIGUS, I., CLAEYS, M. J., LABORDE, J. C., PARIZEL, P. M., VRINTS, C. J. & BOSMANS, J. M. 2011. Comparison of magnetic resonance imaging of aortic valve stenosis and aortic root to multimodality imaging for selection of transcatheter aortic valve implantation candidates. Am J Cardiol, 108, 92-8. PEGG, T. J., SELVANAYAGAM, J. B., KARAMITSOS, T. D., ARNOLD, R. J., FRANCIS, J. M., NEUBAUER, S. & TAGGART, D. P. 2008. Effects of off-pump versus on-pump coronary artery bypass grafting on early and late right ventricular function. Circulation, 117, 2202-10. PIAZZA, N., GRUBE, E., GERCKENS, U., DEN HEIJER, P., LINKE, A., LUHA, O., RAMONDO, A., USSIA, G., WENAWESER, P., WINDECKER, S., LABORDE, J. C., DE JAEGERE, P. & SERRUYS, P. W. 2008. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention, 4, 242-9. PIBAROT, P. & DUMESNIL, J. G. 2010. Longitudinal myocardial shortening in aortic stenosis: ready for prime time after 30 years of research? Heart, 96, 95-6. PIBAROT, P., HAHN, R. T., WEISSMAN, N. J. & MONAGHAN, M. J. 2015. Assessment of paravalvular regurgitation following TAVR: a proposal of unifying grading scheme. JACC Cardiovasc Imaging, 8, 340-60. PINZANI, A., DE GEVIGNEY, G., PINZANI, V., NINET, J., MILON, H. & DELAHAYE, J. P. 1993. [Pre- and postoperative right cardiac insufficiency in patients with mitral or mitral-aortic valve diseases]. Arch Mal Coeur Vaiss, 86, 27-34. POPMA, J. J., ADAMS, D. H., REARDON, M. J., YAKUBOV, S. J., KLEIMAN, N. S., HEIMANSOHN, D., HERMILLER, J., JR., HUGHES, G. C., HARRISON, J. K., COSELLI, J., DIEZ, J., KAFI, A., SCHREIBER, T., GLEASON, T. G., CONTE, J., BUCHBINDER, M., DEEB, G. M., CARABELLO, B., SERRUYS, P. W., CHENOWETH, S. & OH, J. 2014. Transcatheter Aortic Valve Replacement Using A Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis at Extreme Risk for Surgery. J Am Coll Cardiol. POULIN, F., CARASSO, S., HORLICK, E. M., RAKOWSKI, H., LIM, K. D., FINN, H., FEINDEL, C. M., GREUTMANN, M., OSTEN, M. D., CUSIMANO, R. J. & WOO, A. 2014. Recovery of left ventricular mechanics after transcatheter aortic valve implantation: effects of baseline ventricular function and postprocedural aortic regurgitation. J Am Soc Echocardiogr, 27, 1133-42. PUENTES, M., MESA, D., RUIZ ORTIZ, M., DELGADO, M., MAZUELOS, F. & SUAREZ DE LEZO, J. 2012. Changes in right ventricular systolic function after transcatheter aortic valve implantation assessed by two-dimensional speckle tracking echocardiography. Rev Esp Cardiol (Engl Ed), 65, 964-5. QUARTO, C., DWECK, M. R., MURIGU, T., JOSHI, S., MELINA, G., ANGELONI, E., PRASAD, S. K. & PEPPER, J. R. 2012. Late gadolinium enhancement as a potential marker of increased perioperative risk in aortic valve replacement. Interact Cardiovasc Thorac Surg, 15, 45-50. QUICK, S., SPEISER, U., PFLUECKE, C., YOUSSEF, A., SVERIC, K., STRASSER, R. & IBRAHIM, K. 2013. Aortic stenosis: right and left ventricular function in the early postprocedural phase. Comparison between transcatheter and surgical aortic valve implantation. Acta Cardiol, 68, 583-9. RADER, F., SACHDEV, E., ARSANJANI, R. & SIEGEL, R. J. 2015. Left ventricular hypertrophy in valvular aortic stenosis: mechanisms and clinical implications. Am J Med, 128, 344-52. RAJAMANNAN, N. M., EVANS, F. J., AIKAWA, E., GRANDE-ALLEN, K. J., DEMER, L. L., HEISTAD, D. D., SIMMONS, C. A., MASTERS, K. S., MATHIEU, P., O'BRIEN, K. D., SCHOEN, F. J., TOWLER, D. A., YOGANATHAN, A. P. & OTTO, C. M. 2011. Calcific aortic valve disease: not simply a degenerative process: A review and agenda for research from the National Heart and Lung and Blood Institute Aortic Stenosis Working Group. Executive summary: Calcific aortic valve disease-2011 update. Circulation, 124, 1783-91. RAJAPPAN, K., RIMOLDI, O. E., CAMICI, P. G., BELLENGER, N. G., PENNELL, D. J. & SHERIDAN, D. J. 2003. Functional changes in coronary microcirculation after valve replacement in patients with aortic stenosis. Circulation, 107, 3170-5. REARDON, M. J., ADAMS, D. H., KLEIMAN, N. S., YAKUBOV, S. J., COSELLI, J. S., DEEB, G. M., GLEASON, T. G., LEE, J. S., HERMILLER, J. B., JR., CHETCUTI, S., HEISER, J., MERHI, W., ZORN, G. L., 3RD, TADROS, P., ROBINSON, N., PETROSSIAN, G., HUGHES, G. C., HARRISON, J. K., MAINI, B., MUMTAZ, M., CONTE, J. V., RESAR, J. R., AHARONIAN, V., PFEFFER, T., OH, J. K., QIAO, H. & POPMA, J. J. 2015. 2-Year Outcomes in Patients Undergoing Surgical or Self-Expanding Transcatheter Aortic Valve Replacement. J Am Coll Cardiol, 66, 113-21. RIBEIRO, H. B., LE VEN, F., LAROSE, E., DAHOU, A., NOMBELA-FRANCO, L., URENA, M., ALLENDE, R., AMAT-SANTOS, I., RICAPITO MDE, L., THEBAULT, C., CLAVEL, M. A., DELAROCHELLIERE, R., DOYLE, D., DUMONT, E., DUMESNIL, J. G., PIBAROT, P. & RODES-CABAU, J. 2014. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation. Heart, 100, 1924-32. RIPLEY, D. P., MOTWANI, M., PLEIN, S. & GREENWOOD, J. P. 2014. Established and emerging cardiovascular magnetic resonance techniques for the assessment of stable coronary heart disease and acute coronary syndromes. Quant Imaging Med Surg, 4, 330-44. RIPLEY, D. P., NEGROU, K., OLIVER, J. J., WORTHY, G., STRUTHERS, A. D., PLEIN, S. & GREENWOOD, J. P. 2015. Aortic remodelling following the treatment and regression of hypertensive left ventricular hypertrophy: a cardiovascular magnetic resonance study. Clin Exp Hypertens, 37, 308-16. RODES-CABAU, J., WEBB, J. G., CHEUNG, A., YE, J., DUMONT, E., FEINDEL, C. M., OSTEN, M., NATARAJAN, M. K., VELIANOU, J. L., MARTUCCI, G., DEVARENNES, B., CHISHOLM, R., PETERSON, M. D., LICHTENSTEIN, S. V., NIETLISPACH, F., DOYLE, D., DELAROCHELLIERE, R., TEOH, K., CHU, V., DANCEA, A., LACHAPELLE, K., CHEEMA, A., LATTER, D. & HORLICK, E. 2010. Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. J Am Coll Cardiol, 55, 1080-90. ROSS, D. N. 1962. Homograft replacement of the aortic valve. Lancet, 2, 487. ROSS, J., JR. 1976. Afterload mismatch and preload reserve: a conceptual framework for the analysis of ventricular function. Prog Cardiovasc Dis, 18, 255-64. ROSS, J., JR. & BRAUNWALD, E. 1968. Aortic stenosis. Circulation, 38, 61-7. ROST, C., KORDER, S., WASMEIER, G., WU, M., KLINGHAMMER, L., FLACHSKAMPF, F. A., DANIEL, W. G. & VOIGT, J. U. 2010. Sequential changes in myocardial function after valve replacement for aortic stenosis by speckle tracking echocardiography. Eur J Echocardiogr, 11, 584-9. RUPARELIA, N. & PRENDERGAST, B. D. 2015. TAVI in 2015: who, where and how? Heart, 101, 1422-31. SALAUN, E., JACQUIER, A., THERON, A., GIORGI, R., LAMBERT, M., JAUSSAUD, N., HUBERT, S., COLLART, F., BONNET, J. L., HABIB, G., CUISSET, T. & GRISOLI, D. 2015. Value of CMR in quantification of paravalvular aortic regurgitation after TAVI. Eur Heart J Cardiovasc Imaging. SALIS, S., MAZZANTI, V. V., MERLI, G., SALVI, L., TEDESCO, C. C., VEGLIA, F. & SISILLO, E. 2008. Cardiopulmonary bypass duration is an independent predictor of morbidity and mortality after cardiac surgery. J Cardiothorac Vasc Anesth, 22, 814-22. SANDSTEDE, J. J., JOHNSON, T., HARRE, K., BEER, M., HOFMANN, S., PABST, T., KENN, W., VOELKER, W., NEUBAUER, S. & HAHN, D. 2002. Cardiac systolic rotation and contraction before and after valve replacement for aortic stenosis: a myocardial tagging study using MR imaging. AJR Am J Roentgenol, 178, 953-8. SANNINO, A., GARGIULO, G., SCHIATTARELLA, G. G., BREVETTI, L., PERRINO, C., STABILE, E., LOSI, M. A., TOSCANO, E., GIUGLIANO, G., SCUDIERO, F., CHIACCHIO, E., TRIMARCO, B. & ESPOSITO, G. 2014. Increased mortality after transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and low ejection fraction: a meta-analysis of 6898 patients. Int J Cardiol, 176, 32-9. SANZ, J. & DANGAS, G. 2014. Myocardial damage after TAVR assessed with CMR: a new piece in a puzzle? J Am Coll Cardiol, 64, 358-60. SCHMIDTKE, C., BECHTEL, J., HUEPPE, M., NOETZOLD, A. & SIEVERS, H. H. 2000. Size and distensibility of the aortic root and aortic valve function after different techniques of the ross procedure. J Thorac Cardiovasc Surg, 119, 990-7. SCHULZ-MENGER, J., BLUEMKE, D. A., BREMERICH, J., FLAMM, S. D., FOGEL, M. A., FRIEDRICH, M. G., KIM, R. J., VON KNOBELSDORFF-BRENKENHOFF, F., KRAMER, C. M., PENNELL, D. J., PLEIN, S. & NAGEL, E. 2013. Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) board of trustees task force on standardized post processing. J Cardiovasc Magn Reson, 15, 35. SENGUPTA, P. P., TAJIK, A. J., CHANDRASEKARAN, K. & KHANDHERIA, B. K. 2008. Twist mechanics of the left ventricle: principles and application. JACC Cardiovasc Imaging, 1, 366-76. SHAH, A. S., CHIN, C. W., VASSILIOU, V., COWELL, S. J., DORIS, M., KWOK, T. C., SEMPLE, S., ZAMVAR, V., WHITE, A. C., MCKILLOP, G., BOON, N. A., PRASAD, S. K., MILLS, N. L., NEWBY, D. E. & DWECK, M. R. 2014. Left ventricular hypertrophy with strain and aortic stenosis. Circulation, 130, 1607-16. SHERIF, M. A., ABDEL-WAHAB, M., BEURICH, H. W., STOCKER, B., ZACHOW, D., GEIST, V., TOLG, R. & RICHARDT, G. 2011. Haemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using cardiovascular magnetic resonance. EuroIntervention, 7, 57-63. SINGH, A., FORD, I., GREENWOOD, J. P., KHAN, J. N., UDDIN, A., BERRY, C., NEUBAUER, S., PRENDERGAST, B., JEROSCH-HEROLD, M., WILLIAMS, B., SAMANI, N. J. & MCCANN, G. P. 2013. Rationale and design of the PRognostic Importance of MIcrovascular Dysfunction in asymptomatic patients with Aortic Stenosis (PRIMID-AS): a multicentre observational study with blinded investigations. BMJ Open, 3, e004348. SINGH, A., STEADMAN, C. D., KHAN, J. N., HORSFIELD, M. A., BEKELE, S., NAZIR, S. A., KANAGALA, P., MASCA, N. G., CLARYSSE, P. & MCCANN, G. P. 2015. Intertechnique agreement and interstudy reproducibility of strain and diastolic strain rate at 1.5 and 3 Tesla: a comparison of feature-tracking and tagging in patients with aortic stenosis. J Magn Reson Imaging, 41, 1129-37. SINGH, A., STEADMAN, C. D. & MCCANN, G. P. 2014. Advances in the understanding of the pathophysiology and management of aortic stenosis: role of novel imaging techniques. Can J Cardiol, 30, 994-1003. SINNING, J. M., HAMMERSTINGL, C., VASA-NICOTERA, M., ADENAUER, V., LEMA CACHIGUANGO, S. J., SCHEER, A. C., HAUSEN, S., SEDAGHAT, A., GHANEM, A., MULLER, C., GRUBE, E., NICKENIG, G. & WERNER, N. 2012. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. J Am Coll Cardiol, 59, 1134-41. SINNING, J. M., VASA-NICOTERA, M., CHIN, D., HAMMERSTINGL, C., GHANEM, A., BENCE, J., KOVAC, J., GRUBE, E., NICKENIG, G. & WERNER, N. 2013. Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement. J Am Coll Cardiol, 62, 11-20. SMITH, C. R., LEON, M. B., MACK, M. J., MILLER, D. C., MOSES, J. W., SVENSSON, L. G., TUZCU, E. M., WEBB, J. G., FONTANA, G. P., MAKKAR, R. R., WILLIAMS, M., DEWEY, T., KAPADIA, S., BABALIAROS, V., THOURANI, V. H., CORSO, P., PICHARD, A. D., BAVARIA, J. E., HERRMANN, H. C., AKIN, J. J., ANDERSON, W. N., WANG, D., POCOCK, S. J. & INVESTIGATORS, P. T. 2011. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med, 364, 2187-98. SORAJJA, P. & PEDERSEN, W. 2014. Next-generation transcatheter aortic valve replacement: evolution of a revolution. J Am Coll Cardiol, 64, 1349-51. SPETHMANN, S., DREGER, H., SCHATTKE, S., BALDENHOFER, G., SAGHABALYAN, D., STANGL, V., LAULE, M., BAUMANN, G., STANGL, K. & KNEBEL, F. 2012. Doppler haemodynamics and effective orifice areas of Edwards SAPIEN and CoreValve transcatheter aortic valves. Eur Heart J Cardiovasc Imaging, 13, 690-6. STAHLI, B. E., MAIER, W., CORTI, R., LUSCHER, T. F., JENNI, R. & TANNER, F. C. 2013. Aortic regurgitation after transcatheter aortic valve implantation: mechanisms and implications. Cardiovasc Diagn Ther, 3, 15-22. STANKOVIC, Z., ALLEN, B. D., GARCIA, J., JARVIS, K. B. & MARKL, M. 2014. 4D flow imaging with MRI. Cardiovasc Diagn Ther, 4, 173-92. STEADMAN, C. D., JEROSCH-HEROLD, M., GRUNDY, B., RAFELT, S., NG, L. L., SQUIRE, I. B., SAMANI, N. J. & MCCANN, G. P. 2012. Determinants and functional significance of myocardial perfusion reserve in severe aortic stenosis. JACC Cardiovasc Imaging, 5, 182-9. STEFANADIS, C., VLACHOPOULOS, C., KARAYANNACOS, P., BOUDOULAS, H., STRATOS, C., FILIPPIDES, T., AGAPITOS, M. & TOUTOUZAS, P. 1995. Effect of vasa vasorum flow on structure and function of the aorta in experimental animals. Circulation, 91, 2669-78. STOKLAND, O., MILLER, M. M., ILEBEKK, A. & KIIL, F. 1980. Mechanism of hemodynamic responses to occlusion of the descending thoracic aorta. Am J Physiol, 238, H423-9. STUBER, M., SCHEIDEGGER, M. B., FISCHER, S. E., NAGEL, E., STEINEMANN, F., HESS, O. M. & BOESIGER, P. 1999. Alterations in the local myocardial motion pattern in patients suffering from pressure overload due to aortic stenosis. Circulation, 100, 361-8. SWOBODA, P. P., LARGHAT, A., ZAMAN, A., FAIRBAIRN, T. A., MOTWANI, M., GREENWOOD, J. P. & PLEIN, S. 2014. Reproducibility of myocardial strain and left ventricular twist measured using complementary spatial modulation of magnetization. J Magn Reson Imaging, 39, 887-94. TAMBORINI, G., MURATORI, M., BRUSONI, D., CELESTE, F., MAFFESSANTI, F., CAIANI, E. G., ALAMANNI, F. & PEPI, M. 2009. Is right ventricular systolic function reduced after cardiac surgery? A two- and three-dimensional echocardiographic study. Eur J Echocardiogr, 10, 630-4. TAMBURINO, C., CAPODANNO, D., RAMONDO, A., PETRONIO, A. S., ETTORI, F., SANTORO, G., KLUGMANN, S., BEDOGNI, F., MAISANO, F., MARZOCCHI, A., POLI, A., ANTONIUCCI, D., NAPODANO, M., DE CARLO, M., FIORINA, C. & USSIA, G. P. 2011. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation, 123, 299-308. THADEN, J. J., NKOMO, V. T. & ENRIQUEZ-SARANO, M. 2014. The global burden of aortic stenosis. Prog Cardiovasc Dis, 56, 565-71. TRAUZEDDEL, R. F., LOBE, U., BARKER, A. J., GELSINGER, C., BUTTER, C., MARKL, M., SCHULZ-MENGER, J. & VON KNOBELSDORFF-BRENKENHOFF, F. 2015. Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement. Int J Cardiovasc Imaging. UDDIN, A., FAIRBAIRN, T. A., DJOUKHADER, I. K., IGRA, M., KIDAMBI, A., MOTWANI, M., HERZOG, B., RIPLEY, D. P., MUSA, T. A., GODDARD, A. J., BLACKMAN, D. J., PLEIN, S. & GREENWOOD, J. P. 2015. Consequence of cerebral embolism after transcatheter aortic valve implantation compared with contemporary surgical aortic valve replacement: effect on health-related quality of life. Circ Cardiovasc Interv, 8, e001913. UNSWORTH, B., CASULA, R. P., YADAV, H., BARUAH, R., HUGHES, A. D., MAYET, J. & FRANCIS, D. P. 2013. Contrasting effect of different cardiothoracic operations on echocardiographic right ventricular long axis velocities, and implications for interpretation of post-operative values. Int J Cardiol, 165, 151-60. UNSWORTH, B., FRANCIS, D. P. & MAYET, J. 2014. RE: impact of transcatheter aortic valve implantation or surgical aortic valve replacement on right ventricular function. Heart, 100, 180. USSIA, G. P., BARBANTI, M., PETRONIO, A. S., TARANTINI, G., ETTORI, F., COLOMBO, A., VIOLINI, R., RAMONDO, A., SANTORO, G., KLUGMANN, S., BEDOGNI, F., MAISANO, F., MARZOCCHI, A., POLI, A., DE CARLO, M., NAPODANO, M., FIORINA, C., DE MARCO, F., ANTONIUCCI, D., DE CILLIS, E., CAPODANNO, D. & TAMBURINO, C. 2012. Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis. Eur Heart J, 33, 969-76. VAHANIAN, A., ALFIERI, O., AL-ATTAR, N., ANTUNES, M., BAX, J., CORMIER, B., CRIBIER, A., DE JAEGERE, P., FOURNIAL, G., KAPPETEIN, A. P., KOVAC, J., LUDGATE, S., MAISANO, F., MOAT, N., MOHR, F., NATAF, P., PIERARD, L., POMAR, J. L., SCHOFER, J., TORNOS, P., TUZCU, M., VAN HOUT, B., VON SEGESSER, L. K. & WALTHER, T. 2008. Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J, 29, 1463-70. VAHANIAN, A., ALFIERI, O., ANDREOTTI, F., ANTUNES, M. J., BARON-ESQUIVIAS, G., BAUMGARTNER, H., BORGER, M. A., CARREL, T. P., DE BONIS, M., EVANGELISTA, A., FALK, V., LUNG, B., LANCELLOTTI, P., PIERARD, L., PRICE, S., SCHAFERS, H. J., SCHULER, G., STEPINSKA, J., SWEDBERG, K., TAKKENBERG, J., VON OPPELL, U. O., WINDECKER, S., ZAMORANO, J. L., ZEMBALA, M., GUIDELINES, E. S. C. C. F. P., JOINT TASK FORCE ON THE MANAGEMENT OF VALVULAR HEART DISEASE OF THE EUROPEAN SOCIETY OF, C. & EUROPEAN ASSOCIATION FOR CARDIO-THORACIC, S. 2012. Guidelines on the management of valvular heart disease (version 2012): the Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg, 42, S1-44. VAQUETTE, B., CORBINEAU, H., LAURENT, M., LELONG, B., LANGANAY, T., DE PLACE, C., FROGER-BOMPAS, C., LECLERCQ, C., DAUBERT, C. & LEGUERRIER, A. 2005. Valve replacement in patients with critical aortic stenosis and depressed left ventricular function: predictors of operative risk, left ventricular function recovery, and long term outcome. Heart, 91, 1324-9. VAVURANAKIS, M., VRACHATIS, D. A., BOUDOULAS, H., PAPAIOANNOU, T. G., MOLDOVAN, C., KARIORI, M. G., KALOGERAS, K. I., PIETRI, P. G., TENTOLOURIS, C. & STEFANADIS, C. 2012. Effect of transcatheter aortic valve implantation on the ascending aorta's elasticity. Clin Res Cardiol, 101, 895-9. VIZZARDI, E., D'ALOIA, A., FIORINA, C., BUGATTI, S., PARRINELLO, G., DE CARLO, M., GIANNINI, C., DI BELLO, V., PETRONIO, A. S., CURELLO, S., ETTORI, F. & DEI CAS, L. 2012. Early regression of left ventricular mass associated with diastolic improvement after transcatheter aortic valve implantation. J Am Soc Echocardiogr, 25, 1091-8. VLACHOPOULOS, C., AZNAOURIDIS, K. & STEFANADIS, C. 2010. Prediction of cardiovascular events and all-cause mortality with arterial stiffness: a systematic review and meta-analysis. J Am Coll Cardiol, 55, 1318-27. VON KNOBELSDORFF-BRENKENHOFF, F., TRAUZEDDEL, R. F., BARKER, A. J., GRUETTNER, H., MARKL, M. & SCHULZ-MENGER, J. 2014. Blood flow characteristics in the ascending aorta after aortic valve replacement--a pilot study using 4D-flow MRI. Int J Cardiol, 170, 426-33. WALTHER, T., BLUMENSTEIN, J., VAN LINDEN, A. & KEMPFERT, J. 2012. Contemporary management of aortic stenosis: surgical aortic valve replacement remains the gold standard. Heart, 98 Suppl 4, iv23-9. WANG, B., CHEN, H., SHU, X., HONG, T., LAI, H., WANG, C. & CHENG, L. 2013. Emerging role of echocardiographic strain/strain rate imaging and twist in systolic function evaluation and operative procedure in patients with aortic stenosis. Interact Cardiovasc Thorac Surg, 17, 384-91. WEBB, J. G., CHANDAVIMOL, M., THOMPSON, C. R., RICCI, D. R., CARERE, R. G., MUNT, B. I., BULLER, C. E., PASUPATI, S. & LICHTENSTEIN, S. 2006. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation, 113, 842-50. WEBB, J. G. & WOOD, D. A. 2012. Current status of transcatheter aortic valve replacement. J Am Coll Cardiol, 60, 483-92. WEIDEMANN, F., HERRMANN, S., STORK, S., NIEMANN, M., FRANTZ, S., LANGE, V., BEER, M., GATTENLOHNER, S., VOELKER, W., ERTL, G. & STROTMANN, J. M. 2009. Impact of myocardial fibrosis in patients with symptomatic severe aortic stenosis. Circulation, 120, 577-84. WENAWESER, P. & O'SULLIVAN, C. J. 2012. Aortic stenosis and the right heart at risk: is transcatheter aortic valve implantation the better option? Heart, 98, 1265-6. YOUNG, A. A. & COWAN, B. R. 2012. Evaluation of left ventricular torsion by cardiovascular magnetic resonance. J Cardiovasc Magn Reson, 14, 49. ZHAO, Y., LINDQVIST, P., NILSSON, J., HOLMGREN, A., NASLUND, U. & HENEIN, M. Y. 2011. Trans-catheter aortic valve implantation--early recovery of left and preservation of right ventricular function. Interact Cardiovasc Thorac Surg, 12, 35-9."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.695953"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["PG/11/126/29321"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/15238/1/TAM_PhD_Thesis_FINAL_POST_MINOR_REVISIONS.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Background: Surgical aortic valve replacement (SAVR) remains first-line treatment for symptomatic severe aortic stenosis, whereas transcatheter aortic valve implantation (TAVI) is indicated in patients who are inoperable or considered too high-risk for surgery. Current focus is centred on differences in the impact of valve replacement upon cardiovascular function to guide patient selection and the development of novel prosthetic valves to improve outcomes. Cardiovascular Magnetic Resonance (CMR) imaging is the investigative modality of choice for such a purpose. Objectives: To compare the impact of SAVR and TAVI upon aortic stiffness, right ventricular function and myocardial strain, and to compare two vendor designs in the quantity of post-TAVI aortic regurgitation and reverse remodelling. Methods: A prospective study of patients with severe aortic stenosis under surveillance and subsequently requiring SAVR or TAVI, recruited between September 2009 and December 2015. A 1.5 Tesla CMR study was performed pre and 6 months post SAVR, and pre, immediately and 6 months post implantation of Medtronic CoreValve and Boston Lotus TAVI. Aortic distensibility (AD), pulse wave velocity (PWV), right ventricular (RV) volumes, myocardial strain and aortic regurgitation (AR) were quantified. Results: At 6 months, SAVR was associated with a significant worsening in PWV (6.38±4.47 vs. 11.01±5.75ms-1, p=0.001) and ascending AD (1.95±1.15 vs. 1.57±0.68x10-3mmHg-1, p=0.044), whereas no change was seen following TAVI. A significant reduction in RV ejection fraction (58±8 vs. 53±8%, p=0.005) was seen flowing SAVR, with no change following TAVI. A significant and comparable decline in LV torsion and twist was observed. Baseline circumferential strain was significantly associated with all-cause mortality (hazard ratio, 1.03; 1.01–1.05; p=0.009). Significantly less AR was seen immediately following Lotus than CoreValve TAVI (4.3±3.4 vs.11.7±8.4%, p=0.001) with equivalent degrees of reverse remodelling observed at 6 months. Conclusion: Compared with TAVI, SAVR is more detrimental upon aortic stiffness and right ventricular function at 6 months. CMR derived circumferential strain is associated with survival following SAVR and TAVI."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Transcatheter and Surgical Aortic Valve Replacement for Severe Aortic Stenosis: Insights from Cardiovascular Magnetic Resonance Imaging"]}]}],"canonical_facts":{"dc:contributor.advisor":["Greenwood, John P","Plein, Sven"],"dc:contributor.sponsor":["British Heart Foundation"],"dc:creator":["Musa, Tarique Al"],"dc:date":["2016-05"],"dc:date.issued":["2016-05"],"dc:description.abstract":["Background: Surgical aortic valve replacement (SAVR) remains first-line treatment for symptomatic severe aortic stenosis, whereas transcatheter aortic valve implantation (TAVI) is indicated in patients who are inoperable or considered too high-risk for surgery. Current focus is centred on differences in the impact of valve replacement upon cardiovascular function to guide patient selection and the development of novel prosthetic valves to improve outcomes. Cardiovascular Magnetic Resonance (CMR) imaging is the investigative modality of choice for such a purpose. Objectives: To compare the impact of SAVR and TAVI upon aortic stiffness, right ventricular function and myocardial strain, and to compare two vendor designs in the quantity of post-TAVI aortic regurgitation and reverse remodelling. Methods: A prospective study of patients with severe aortic stenosis under surveillance and subsequently requiring SAVR or TAVI, recruited between September 2009 and December 2015. A 1.5 Tesla CMR study was performed pre and 6 months post SAVR, and pre, immediately and 6 months post implantation of Medtronic CoreValve and Boston Lotus TAVI. Aortic distensibility (AD), pulse wave velocity (PWV), right ventricular (RV) volumes, myocardial strain and aortic regurgitation (AR) were quantified. Results: At 6 months, SAVR was associated with a significant worsening in PWV (6.38±4.47 vs. 11.01±5.75ms-1, p=0.001) and ascending AD (1.95±1.15 vs. 1.57±0.68x10-3mmHg-1, p=0.044), whereas no change was seen following TAVI. A significant reduction in RV ejection fraction (58±8 vs. 53±8%, p=0.005) was seen flowing SAVR, with no change following TAVI. A significant and comparable decline in LV torsion and twist was observed. Baseline circumferential strain was significantly associated with all-cause mortality (hazard ratio, 1.03; 1.01–1.05; p=0.009). Significantly less AR was seen immediately following Lotus than CoreValve TAVI (4.3±3.4 vs.11.7±8.4%, p=0.001) with equivalent degrees of reverse remodelling observed at 6 months. Conclusion: Compared with TAVI, SAVR is more detrimental upon aortic stiffness and right ventricular function at 6 months. CMR derived circumferential strain is associated with survival following SAVR and TAVI."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.695953"],"dc:identifier.grantnumber":["PG/11/126/29321"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/15238/1/TAM_PhD_Thesis_FINAL_POST_MINOR_REVISIONS.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Academic Unit of Cardiovascular Medicine (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/15238/"],"dc:relation.references":["2010. Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: 'establishing normal and reference values'. Eur Heart J, 31, 2338-50. ABDEL-WAHAB, M., MEHILLI, J., FRERKER, C., NEUMANN, F. J., KURZ, T., TOLG, R., ZACHOW, D., GUERRA, E., MASSBERG, S., SCHAFER, U., EL-MAWARDY, M., RICHARDT, G. & INVESTIGATORS, C. 2014. Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA, 311, 1503-14. ADAMS, D. H., POPMA, J. J., REARDON, M. J., YAKUBOV, S. J., COSELLI, J. S., DEEB, G. M., GLEASON, T. G., BUCHBINDER, M., HERMILLER, J., JR., KLEIMAN, N. S., CHETCUTI, S., HEISER, J., MERHI, W., ZORN, G., TADROS, P., ROBINSON, N., PETROSSIAN, G., HUGHES, G. C., HARRISON, J. K., CONTE, J., MAINI, B., MUMTAZ, M., CHENOWETH, S. & OH, J. K. 2014. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med, 370, 1790-8. ALI, A., PATEL, A., ALI, Z., ABU-OMAR, Y., SAEED, A., ATHANASIOU, T. & PEPPER, J. 2011. Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival. J Thorac Cardiovasc Surg, 142, 285-91. ALTIOK, E., FRICK, M., MEYER, C. G., AL ATEAH, G., NAPP, A., KIRSCHFINK, A., ALMALLA, M., LOTFI, S., BECKER, M., HERICH, L., LEHMACHER, W. & HOFFMANN, R. 2014. Comparison of two- and three-dimensional transthoracic echocardiography to cardiac magnetic resonance imaging for assessment of paravalvular regurgitation after transcatheter aortic valve implantation. Am J Cardiol, 113, 1859-66. AMBALE-VENKATESH, B. & LIMA, J. A. 2015. Cardiac MRI: a central prognostic tool in myocardial fibrosis. Nat Rev Cardiol, 12, 18-29. ANGOURAS, D., SOKOLIS, D. P., DOSIOS, T., KOSTOMITSOPOULOS, N., BOUDOULAS, H., SKALKEAS, G. & KARAYANNACOS, P. E. 2000. Effect of impaired vasa vasorum flow on the structure and mechanics of the thoracic aorta: implications for the pathogenesis of aortic dissection. Eur J Cardiothorac Surg, 17, 468-73. ASIMAKOPOULOS, G., EDWARDS, M. B. & TAYLOR, K. M. 1997. Aortic valve replacement in patients 80 years of age and older: survival and cause of death based on 1100 cases: collective results from the UK Heart Valve Registry. Circulation, 96, 3403-8. ASMAR, R., BENETOS, A., LONDON, G., HUGUE, C., WEISS, Y., TOPOUCHIAN, J., LALOUX, B. & SAFAR, M. 1995. Aortic distensibility in normotensive, untreated and treated hypertensive patients. Blood Press, 4, 48-54. ASMAR, R. G., PANNIER, B., SANTONI, J. P., LAURENT, S., LONDON, G. M., LEVY, B. I. & SAFAR, M. E. 1988. Reversion of cardiac hypertrophy and reduced arterial compliance after converting enzyme inhibition in essential hypertension. Circulation, 78, 941-50. ATHAPPAN, G., PATVARDHAN, E., TUZCU, E. M., SVENSSON, L. G., LEMOS, P. A., FRACCARO, C., TARANTINI, G., SINNING, J. M., NICKENIG, G., CAPODANNO, D., TAMBURINO, C., LATIB, A., COLOMBO, A. & KAPADIA, S. R. 2013. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol, 61, 1585-95. ATTIAS, D., MACRON, L., DREYFUS, J., MONIN, J. L., BROCHET, E., LEPAGE, L., HEKIMIAN, G., IUNG, B., VAHANIAN, A. & MESSIKA-ZEITOUN, D. 2013. Relationship between longitudinal strain and symptomatic status in aortic stenosis. J Am Soc Echocardiogr, 26, 868-74. AYHAN, H., DURMAZ, T., KELES, T., SARI, C., ASLAN, A. N., KASAPKARA, H. A. & BOZKURT, E. 2014. Improvement of right ventricular function with transcatheter aortic valve implantation. Scand Cardiovasc J, 48, 184-8. AZEVEDO, C. F., NIGRI, M., HIGUCHI, M. L., POMERANTZEFF, P. M., SPINA, G. S., SAMPAIO, R. O., TARASOUTCHI, F., GRINBERG, M. & ROCHITTE, C. E. 2010. Prognostic significance of myocardial fibrosis quantification by histopathology and magnetic resonance imaging in patients with severe aortic valve disease. J Am Coll Cardiol, 56, 278-87. BARBETSEAS, J., ALEXOPOULOS, N., BRILI, S., AGGELI, C., MARINAKIS, N., VLACHOPOULOS, C., VYSSOULIS, G. & STEFANADIS, C. 2006. Changes in aortic root function after valve replacement in patients with aortic stenosis. Int J Cardiol, 110, 74-9. BARONE-ROCHETTE, G., PIERARD, S., DE MEESTER DE RAVENSTEIN, C., SELDRUM, S., MELCHIOR, J., MAES, F., POULEUR, A. C., VANCRAEYNEST, D., PASQUET, A., VANOVERSCHELDE, J. L. & GERBER, B. L. 2014. Prognostic significance of LGE by CMR in aortic stenosis patients undergoing valve replacement. J Am Coll Cardiol, 64, 144-54. BAUER, F., LEMERCIER, M., ZAJARIAS, A., TRON, C., ELTCHANINOFF, H. & CRIBIER, A. 2010. Immediate and long-term echocardiographic findings after transcatheter aortic valve implantation for the treatment of aortic stenosis: the Cribier-Edwards/Edwards-Sapien valve experience. J Am Soc Echocardiogr, 23, 370-6. BAUMGARTNER, H., HUNG, J., BERMEJO, J., CHAMBERS, J. B., EVANGELISTA, A., GRIFFIN, B. P., IUNG, B., OTTO, C. M., PELLIKKA, P. A. & QUINONES, M. 2009. Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. Eur J Echocardiogr, 10, 1-25. BEACH, J. M., MIHALJEVIC, T., RAJESWARAN, J., MARWICK, T., EDWARDS, S. T., NOWICKI, E. R., THOMAS, J., SVENSSON, L. G., GRIFFIN, B., GILLINOV, A. M. & BLACKSTONE, E. H. 2014. Ventricular hypertrophy and left atrial dilatation persist and are associated with reduced survival after valve replacement for aortic stenosis. J Thorac Cardiovasc Surg, 147, 362-369 e8. BECKER, M., KRAMANN, R., DOHMEN, G., LUCKHOFF, A., AUTSCHBACH, R., KELM, M. & HOFFMANN, R. 2007. Impact of left ventricular loading conditions on myocardial deformation parameters: analysis of early and late changes of myocardial deformation parameters after aortic valve replacement. J Am Soc Echocardiogr, 20, 681-9. BELLENGER, N. G., BURGESS, M. I., RAY, S. G., LAHIRI, A., COATS, A. J., CLELAND, J. G. & PENNELL, D. J. 2000a. Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J, 21, 1387-96. BELLENGER, N. G., DAVIES, L. C., FRANCIS, J. M., COATS, A. J. & PENNELL, D. J. 2000b. Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Magn Reson, 2, 271-8. BERRY, C., LLOYD, S. M., WANG, Y., MACDONALD, A. & FORD, I. 2013. The changing course of aortic valve disease in Scotland: temporal trends in hospitalizations and mortality and prognostic importance of aortic stenosis. Eur Heart J, 34, 1538-47. BIEDERMAN, R. W., DOYLE, M., YAMROZIK, J., WILLIAMS, R. B., RATHI, V. K., VIDO, D., CARUPPANNAN, K., OSMAN, N., BRESS, V., RAYARAO, G., BIEDERMAN, C. M., MANKAD, S., MAGOVERN, J. A. & REICHEK, N. 2005. Physiologic compensation is supranormal in compensated aortic stenosis: does it return to normal after aortic valve replacement or is it blunted by coexistent coronary artery disease? An intramyocardial magnetic resonance imaging study. Circulation, 112, I429-36. BINDER, R. K. & WEBB, J. G. 2012. TAVI: from home-made prosthesis to global interventional phenomenon. Heart, 98 Suppl 4, iv30-6. BITEKER, M., OZDEN, T., DAYAN, A., TEKKESIN, A. I. & MISIRLI, C. H. 2015. Aortic stiffness and plasma brain natriuretic peptide predicts mortality in acute ischemic stroke. Int J Stroke, 10, 679-85. BLUMENSTEIN, J., LIEBETRAU, C., VAN LINDEN, A., MOELLMANN, H., WALTHER, T. & KEMPFERT, J. 2013. Recent advances in transcatheter aortic valve implantation: novel devices and potential shortcomings. Curr Cardiol Rev, 9, 274-80. BOCK, J., FRYDRYCHOWICZ, A., LORENZ, R., HIRTLER, D., BARKER, A. J., JOHNSON, K. M., ARNOLD, R., BURKHARDT, H., HENNIG, J. & MARKL, M. 2011. In vivo noninvasive 4D pressure difference mapping in the human aorta: phantom comparison and application in healthy volunteers and patients. Magn Reson Med, 66, 1079-88. BRIAND, M., DUMESNIL, J. G., KADEM, L., TONGUE, A. G., RIEU, R., GARCIA, D. & PIBAROT, P. 2005. Reduced systemic arterial compliance impacts significantly on left ventricular afterload and function in aortic stenosis: implications for diagnosis and treatment. J Am Coll Cardiol, 46, 291-8. CARASSO, S., COHEN, O., MUTLAK, D., ADLER, Z., LESSICK, J., ARONSON, D., REISNER, S. A., RAKOWSKI, H., BOLOTIN, G. & AGMON, Y. 2011. Relation of myocardial mechanics in severe aortic stenosis to left ventricular ejection fraction and response to aortic valve replacement. Am J Cardiol, 107, 1052-7. CARASSO, S., COHEN, O., MUTLAK, D., ADLER, Z., LESSICK, J., REISNER, S. A., RAKOWSKI, H., BOLOTIN, G. & AGMON, Y. 2009. Differential effects of afterload on left ventricular long- and short-axis function: insights from a clinical model of patients with aortic valve stenosis undergoing aortic valve replacement. Am Heart J, 158, 540-5. CARASSO, S., MUTLAK, D., LESSICK, J., REISNER, S. A., RAKOWSKI, H. & AGMON, Y. 2015. Symptoms in severe aortic stenosis are associated with decreased compensatory circumferential myocardial mechanics. J Am Soc Echocardiogr, 28, 218-25. CARR-WHITE, G. S., KON, M., KOH, T. W., GLENNAN, S., FERDINAND, F. D., DE SOUZA, A. C., PEPPER, J. R., PENNELL, D. J., GIBSON, D. G. & YACOUB, M. H. 1999. Right ventricular function after pulmonary autograft replacement of the aortic valve. Circulation, 100, II36-41. CAVALCANTE, J. L., LIMA, J. A., REDHEUIL, A. & AL-MALLAH, M. H. 2011. Aortic stiffness: current understanding and future directions. J Am Coll Cardiol, 57, 1511-22. CAWLEY, P. J., HAMILTON-CRAIG, C., OWENS, D. S., KRIEGER, E. V., STRUGNELL, W. E., MITSUMORI, L., D'JANG, C. L., SCHWAEGLER, R. G., NGUYEN, K. Q., NGUYEN, B., MAKI, J. H. & OTTO, C. M. 2013. Prospective comparison of valve regurgitation quantitation by cardiac magnetic resonance imaging and transthoracic echocardiography. Circ Cardiovasc Imaging, 6, 48-57. CHALMERS, J., PULLAN, M., MEDIRATTA, N. & POULLIS, M. 2014. A need for speed? Bypass time and outcomes after isolated aortic valve replacement surgery. Interact Cardiovasc Thorac Surg, 19, 21-6. CHILDS, H., MA, L., MA, M., CLARKE, J., COCKER, M., GREEN, J., STROHM, O. & FRIEDRICH, M. G. 2011. Comparison of long and short axis quantification of left ventricular volume parameters by cardiovascular magnetic resonance, with ex-vivo validation. J Cardiovasc Magn Reson, 13, 40. CHIN, C. W., PAWADE, T. A., NEWBY, D. E. & DWECK, M. R. 2015. Risk Stratification in Patients With Aortic Stenosis Using Novel Imaging Approaches. Circ Cardiovasc Imaging, 8, e003421. CHIN, C. W., SHAH, A. S., MCALLISTER, D. A., JOANNA COWELL, S., ALAM, S., LANGRISH, J. P., STRACHAN, F. E., HUNTER, A. L., MARIA CHOY, A., LANG, C. C., WALKER, S., BOON, N. A., NEWBY, D. E., MILLS, N. L. & DWECK, M. R. 2014a. High-sensitivity troponin I concentrations are a marker of an advanced hypertrophic response and adverse outcomes in patients with aortic stenosis. Eur Heart J, 35, 2312-21. CHIN, C. W., VASSILIOU, V., JENKINS, W. S., PRASAD, S. K., NEWBY, D. E. & DWECK, M. R. 2014b. Markers of left ventricular decompensation in aortic stenosis. Expert Rev Cardiovasc Ther, 12, 901-12. CLAVEL, M. A., WEBB, J. G., RODES-CABAU, J., MASSON, J. B., DUMONT, E., DE LAROCHELLIERE, R., DOYLE, D., BERGERON, S., BAUMGARTNER, H., BURWASH, I. G., DUMESNIL, J. G., MUNDIGLER, G., MOSS, R., KEMPNY, A., BAGUR, R., BERGLER-KLEIN, J., GURVITCH, R., MATHIEU, P. & PIBAROT, P. 2010. Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction. Circulation, 122, 1928-36. CLAYTON, B., MORGAN-HUGHES, G. & ROOBOTTOM, C. 2014. Transcatheter aortic valve insertion (TAVI): a review. Br J Radiol, 87, 20130595. COSTOPOULOS, C., NAGANUMA, T., LATIB, A. & COLOMBO, A. 2013. Aortic regurgitation after transcatheter aortic valve implantation. Expert Rev Cardiovasc Ther, 11, 1089-92. COSTOPOULOS, C., SUTARIA, N., ARIFF, B., FERTLEMAN, M., MALIK, I. & MIKHAIL, G. W. 2015. Balloon aortic valvuloplasty as a treatment option in the era of transcatheter aortic valve implantation. Expert Rev Cardiovasc Ther, 13, 457-60. CREAN, A. M., MAREDIA, N., BALLARD, G., MENEZES, R., WHARTON, G., FORSTER, J., GREENWOOD, J. P. & THOMSON, J. D. 2011. 3D Echo systematically underestimates right ventricular volumes compared to cardiovascular magnetic resonance in adult congenital heart disease patients with moderate or severe RV dilatation. J Cardiovasc Magn Reson, 13, 78. CRIBIER, A., ELTCHANINOFF, H., BASH, A., BORENSTEIN, N., TRON, C., BAUER, F., DERUMEAUX, G., ANSELME, F., LABORDE, F. & LEON, M. B. 2002. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation, 106, 3006-8. CROUCH, G., BENNETTS, J., SINHAL, A., TULLY, P. J., LEONG, D. P., BRADBROOK, C., PENHALL, A. L., DE PASQUALE, C. G., CHAKRABARTY, A., BAKER, R. A. & SELVANAYAGAM, J. B. 2015a. Early effects of transcatheter aortic valve implantation and aortic valve replacement on myocardial function and aortic valve hemodynamics: insights from cardiovascular magnetic resonance imaging. J Thorac Cardiovasc Surg, 149, 462-70. CROUCH, G., TULLY, P. J., BENNETTS, J., SINHAL, A., BRADBROOK, C., PENHALL, A. L., DE PASQUALE, C. G., BAKER, R. A. & SELVANAYAGAM, J. B. 2015b. Quantitative assessment of paravalvular regurgitation following transcatheter aortic valve replacement. J Cardiovasc Magn Reson, 17, 32. D'ONOFRIO, A., FACCHIN, M., BESOLA, L., MANZAN, E., TESSARI, C., BIZZOTTO, E., BIANCO, R., TARANTINI, G., NAPODANO, M., FRACCARO, C., BUJA, P., COVOLO, E., YZEIRAJ, E., PITTARELLO, D., ISABELLA, G., ILICETO, S. & GEROSA, G. 2015. Intermediate Clinical and Hemodynamic Outcomes After Transcatheter Aortic Valve Implantation. Ann Thorac Surg. DAHL, J. S., VIDEBAEK, L., POULSEN, M. K., RUDBAEK, T. R., PELLIKKA, P. A. & MOLLER, J. E. 2012. Global strain in severe aortic valve stenosis: relation to clinical outcome after aortic valve replacement. Circ Cardiovasc Imaging, 5, 613-20. DEBL, K., DJAVIDANI, B., BUCHNER, S., LIPKE, C., NITZ, W., FEUERBACH, S., RIEGGER, G. & LUCHNER, A. 2006. Delayed hyperenhancement in magnetic resonance imaging of left ventricular hypertrophy caused by aortic stenosis and hypertrophic cardiomyopathy: visualisation of focal fibrosis. Heart, 92, 1447-51. DELGADO, V., TOPS, L. F., VAN BOMMEL, R. J., VAN DER KLEY, F., MARSAN, N. A., KLAUTZ, R. J., VERSTEEGH, M. I., HOLMAN, E. R., SCHALIJ, M. J. & BAX, J. J. 2009. Strain analysis in patients with severe aortic stenosis and preserved left ventricular ejection fraction undergoing surgical valve replacement. Eur Heart J, 30, 3037-47. DEVOS, D. G., RIETZSCHEL, E., HEYSE, C., VANDEMAELE, P., VAN BORTEL, L., BABIN, D., SEGERS, P., WESTENBERG, J. M. & ACHTEN, R. 2015. MR pulse wave velocity increases with age faster in the thoracic aorta than in the abdominal aorta. J Magn Reson Imaging, 41, 765-72. DOBSON, L. E., FAIRBAIRN, T. A., PLEIN, S. & GREENWOOD, J. P. 2015. Sex Differences in Aortic Stenosis and Outcome Following Surgical and Transcatheter Aortic Valve Replacement. J Womens Health (Larchmt), 24, 986-95. DOGUI, A., KACHENOURA, N., FROUIN, F., LEFORT, M., DE CESARE, A., MOUSSEAUX, E. & HERMENT, A. 2011. Consistency of aortic distensibility and pulse wave velocity estimates with respect to the Bramwell-Hill theoretical model: a cardiovascular magnetic resonance study. J Cardiovasc Magn Reson, 13, 11. DWECK, M. R., JOSHI, S., MURIGU, T., ALPENDURADA, F., JABBOUR, A., MELINA, G., BANYA, W., GULATI, A., ROUSSIN, I., RAZA, S., PRASAD, N. A., WAGE, R., QUARTO, C., ANGELONI, E., REFICE, S., SHEPPARD, M., COOK, S. A., KILNER, P. J., PENNELL, D. J., NEWBY, D. E., MOHIADDIN, R. H., PEPPER, J. & PRASAD, S. K. 2011. Midwall fibrosis is an independent predictor of mortality in patients with aortic stenosis. J Am Coll Cardiol, 58, 1271-9. DYVERFELDT, P., BISSELL, M., BARKER, A. J., BOLGER, A. F., CARLHALL, C. J., EBBERS, T., FRANCIOS, C. J., FRYDRYCHOWICZ, A., GEIGER, J., GIESE, D., HOPE, M. D., KILNER, P. J., KOZERKE, S., MYERSON, S., NEUBAUER, S., WIEBEN, O. & MARKL, M. 2015. 4D flow cardiovascular magnetic resonance consensus statement. J Cardiovasc Magn Reson, 17, 72. DYVERFELDT, P., GARDHAGEN, R., SIGFRIDSSON, A., KARLSSON, M. & EBBERS, T. 2009. On MRI turbulence quantification. Magn Reson Imaging, 27, 913-22. EVANGELISTA, A., FLACHSKAMPF, F. A., ERBEL, R., ANTONINI-CANTERIN, F., VLACHOPOULOS, C., ROCCHI, G., SICARI, R., NIHOYANNOPOULOS, P., ZAMORANO, J., PEPI, M., BREITHARDT, O. A. & PLONSKA-GOSCINIAK, E. 2010. Echocardiography in aortic diseases: EAE recommendations for clinical practice. Eur J Echocardiogr, 11, 645-58. EVEBORN, G. W., SCHIRMER, H., HEGGELUND, G., LUNDE, P. & RASMUSSEN, K. 2013. The evolving epidemiology of valvular aortic stenosis. the Tromso study. Heart, 99, 396-400. EWE, S. H., MURATORI, M., VAN DER KLEY, F., PEPI, M., DELGADO, V., TAMBORINI, G., FUSINI, L., DE WEGER, A., GRIPARI, P., BARTORELLI, A., BAX, J. J. & MARSAN, N. A. 2015. Effect of aortic regurgitation following transcatheter aortic valve implantation on outcomes. Am J Cardiol, 115, 664-9. FAIRBAIRN, T. A., MEADS, D. M., HULME, C., MATHER, A. N., PLEIN, S., BLACKMAN, D. J. & GREENWOOD, J. P. 2013a. The cost-effectiveness of transcatheter aortic valve implantation versus surgical aortic valve replacement in patients with severe aortic stenosis at high operative risk. Heart, 99, 914-20. FAIRBAIRN, T. A., MEADS, D. M., MATHER, A. N., MOTWANI, M., PAVITT, S., PLEIN, S., BLACKMAN, D. J. & GREENWOOD, J. P. 2012. Serial change in health-related quality of life over 1 year after transcatheter aortic valve implantation: predictors of health outcomes. J Am Coll Cardiol, 59, 1672-80. FAIRBAIRN, T. A., STEADMAN, C. D., MATHER, A. N., MOTWANI, M., BLACKMAN, D. J., PLEIN, S., MCCANN, G. P. & GREENWOOD, J. P. 2013b. Assessment of valve haemodynamics, reverse ventricular remodelling and myocardial fibrosis following transcatheter aortic valve implantation compared to surgical aortic valve replacement: a cardiovascular magnetic resonance study. Heart, 99, 1185-91. FLETT, A. S., HASLETON, J., COOK, C., HAUSENLOY, D., QUARTA, G., ARITI, C., MUTHURANGU, V. & MOON, J. C. 2011. Evaluation of techniques for the quantification of myocardial scar of differing etiology using cardiac magnetic resonance. JACC Cardiovasc Imaging, 4, 150-6. FLETT, A. S., HAYWARD, M. P., ASHWORTH, M. T., HANSEN, M. S., TAYLOR, A. M., ELLIOTT, P. M., MCGREGOR, C. & MOON, J. C. 2010. Equilibrium contrast cardiovascular magnetic resonance for the measurement of diffuse myocardial fibrosis: preliminary validation in humans. Circulation, 122, 138-44. FORSBERG, L. M., TAMAS, E., VANKY, F., NIELSEN, N. E., ENGVALL, J. & NYLANDER, E. 2011. Left and right ventricular function in aortic stenosis patients 8 weeks post-transcatheter aortic valve implantation or surgical aortic valve replacement. Eur J Echocardiogr, 12, 603-11. GAASCH, W. H. & ZILE, M. R. 2011. Left ventricular structural remodeling in health and disease: with special emphasis on volume, mass, and geometry. J Am Coll Cardiol, 58, 1733-40. GALLI, E., LANCELLOTTI, P., SENGUPTA, P. P. & DONAL, E. 2014. LV mechanics in mitral and aortic valve diseases: value of functional assessment beyond ejection fraction. JACC Cardiovasc Imaging, 7, 1151-66. GARCIA, D., CAMICI, P. G., DURAND, L. G., RAJAPPAN, K., GAILLARD, E., RIMOLDI, O. E. & PIBAROT, P. 2009. Impairment of coronary flow reserve in aortic stenosis. J Appl Physiol (1985), 106, 113-21. GATEHOUSE, P. D., KEEGAN, J., CROWE, L. A., MASOOD, S., MOHIADDIN, R. H., KREITNER, K. F. & FIRMIN, D. N. 2005. Applications of phase-contrast flow and velocity imaging in cardiovascular MRI. Eur Radiol, 15, 2172-84. GELFAND, E. V., HUGHES, S., HAUSER, T. H., YEON, S. B., GOEPFERT, L., KISSINGER, K. V., ROFSKY, N. M. & MANNING, W. J. 2006. Severity of mitral and aortic regurgitation as assessed by cardiovascular magnetic resonance: optimizing correlation with Doppler echocardiography. J Cardiovasc Magn Reson, 8, 503-7. GIBBONS, R. J., VALETI, U. S., ARAOZ, P. A. & JAFFE, A. S. 2004. The quantification of infarct size. J Am Coll Cardiol, 44, 1533-42. GOLDBERG, I. J., TRENT, C. M. & SCHULZE, P. C. 2012. Lipid metabolism and toxicity in the heart. Cell Metab, 15, 805-12. GOLDSTEIN, J. A., TWEDDELL, J. S., BARZILAI, B., YAGI, Y., JAFFE, A. S. & COX, J. L. 1991. Right atrial ischemia exacerbates hemodynamic compromise associated with experimental right ventricular dysfunction. J Am Coll Cardiol, 18, 1564-72. GOOLEY, R., LOCKWOOD, S., ANTONIS, P. & MEREDITH, I. T. 2013. The SADRA Lotus Valve System: a fully repositionable, retrievable prosthesis. Minerva Cardioangiol, 61, 45-52. GOOLEY, R. P., TALMAN, A. H., CAMERON, J. D., LOCKWOOD, S. M. & MEREDITH, I. T. 2015. Comparison of Self-Expanding and Mechanically Expanded Transcatheter Aortic Valve Prostheses. JACC Cardiovasc Interv, 8, 962-71. GRABSKAYA, E., BECKER, M., ALTIOK, E., DOHMEN, G., BREHMER, K., HAMADA-LANGER, S., KENNES, L., MARX, N. & HOFFMANN, R. 2011. Impact of transcutaneous aortic valve implantation on myocardial deformation. Echocardiography, 28, 397-401. GROTENHUIS, H. B., OTTENKAMP, J., WESTENBERG, J. J., BAX, J. J., KROFT, L. J. & DE ROOS, A. 2007. Reduced aortic elasticity and dilatation are associated with aortic regurgitation and left ventricular hypertrophy in nonstenotic bicuspid aortic valve patients. J Am Coll Cardiol, 49, 1660-5. GROTHUES, F., MOON, J. C., BELLENGER, N. G., SMITH, G. S., KLEIN, H. U. & PENNELL, D. J. 2004. Interstudy reproducibility of right ventricular volumes, function, and mass with cardiovascular magnetic resonance. Am Heart J, 147, 218-23. GROTHUES, F., SMITH, G. C., MOON, J. C., BELLENGER, N. G., COLLINS, P., KLEIN, H. U. & PENNELL, D. J. 2002. Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol, 90, 29-34. GULATI, A., ISMAIL, T. F., JABBOUR, A., ISMAIL, N. A., MORARJI, K., ALI, A., RAZA, S., KHWAJA, J., BROWN, T. D., LIODAKIS, E., BAKSI, A. J., SHAKUR, R., GUHA, K., ROUGHTON, M., WAGE, R., COOK, S. A., ALPENDURADA, F., ASSOMULL, R. G., MOHIADDIN, R. H., COWIE, M. R., PENNELL, D. J. & PRASAD, S. K. 2013. Clinical utility and prognostic value of left atrial volume assessment by cardiovascular magnetic resonance in non-ischaemic dilated cardiomyopathy. Eur J Heart Fail, 15, 660-70. HACHICHA, Z., DUMESNIL, J. G., BOGATY, P. & PIBAROT, P. 2007. Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with higher afterload and reduced survival. Circulation, 115, 2856-64. HACHICHA, Z., DUMESNIL, J. G. & PIBAROT, P. 2009. Usefulness of the valvuloarterial impedance to predict adverse outcome in asymptomatic aortic stenosis. J Am Coll Cardiol, 54, 1003-11. HAMM, C. W., ARSALAN, M. & MACK, M. J. 2016. The future of transcatheter aortic valve implantation. Eur Heart J, 37, 803-10. HARTLAGE, G. R., BABALIAROS, V. C., THOURANI, V. H., HAYEK, S., CHRYSOHOOU, C., GHASEMZADEH, N., STILLMAN, A. E., CLEMENTS, S. D., OSHINSKI, J. N. & LERAKIS, S. 2014. The role of cardiovascular magnetic resonance in stratifying paravalvular leak severity after transcatheter aortic valve replacement: an observational outcome study. J Cardiovasc Magn Reson, 16, 93. HEIN, S., ARNON, E., KOSTIN, S., SCHONBURG, M., ELSASSER, A., POLYAKOVA, V., BAUER, E. P., KLOVEKORN, W. P. & SCHAPER, J. 2003. Progression from compensated hypertrophy to failure in the pressure-overloaded human heart: structural deterioration and compensatory mechanisms. Circulation, 107, 984-91. HONKONEN, E. L., KAUKINEN, L., PEHKONEN, E. J. & KAUKINEN, S. 1997. Myocardial cooling and right ventricular function in patients with right coronary artery disease: antegrade vs. retrograde cardioplegia. Acta Anaesthesiol Scand, 41, 287-96. HUBER, A., SOURBRON, S., KLAUSS, V., SCHAEFER, J., BAUNER, K. U., SCHWEYER, M., REISER, M., RUMMENY, E. & RIEBER, J. 2012. Magnetic resonance perfusion of the myocardium: semiquantitative and quantitative evaluation in comparison with coronary angiography and fractional flow reserve. Invest Radiol, 47, 332-8. HUFNAGEL, C. A. & HARVEY, W. P. 1953. The surgical correction of aortic regurgitation preliminary report. Bull Georgetown Univ Med Cent, 6, 60-1. IBRAHIM EL, S. H., JOHNSON, K. R., MILLER, A. B., SHAFFER, J. M. & WHITE, R. D. 2010. Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques. J Cardiovasc Magn Reson, 12, 26. IUNG, B., BARON, G., TORNOS, P., GOHLKE-BARWOLF, C., BUTCHART, E. G. & VAHANIAN, A. 2007. Valvular heart disease in the community: a European experience. Curr Probl Cardiol, 32, 609-61. IUNG, B., CACHIER, A., BARON, G., MESSIKA-ZEITOUN, D., DELAHAYE, F., TORNOS, P., GOHLKE-BARWOLF, C., BOERSMA, E., RAVAUD, P. & VAHANIAN, A. 2005. Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? Eur Heart J, 26, 2714-20. IUNG, B. & VAHANIAN, A. 2012. Degenerative calcific aortic stenosis: a natural history. Heart, 98 Suppl 4, iv7-13. IUNG, B. & VAHANIAN, A. 2014. Epidemiology of acquired valvular heart disease. Can J Cardiol, 30, 962-70. IWAHASHI, N., NAKATANI, S., KANZAKI, H., HASEGAWA, T., ABE, H. & KITAKAZE, M. 2006. Acute improvement in myocardial function assessed by myocardial strain and strain rate after aortic valve replacement for aortic stenosis. J Am Soc Echocardiogr, 19, 1238-44. JOINT TASK FORCE ON THE MANAGEMENT OF VALVULAR HEART DISEASE OF THE EUROPEAN SOCIETY OF, C., EUROPEAN ASSOCIATION FOR CARDIO-THORACIC, S., VAHANIAN, A., ALFIERI, O., ANDREOTTI, F., ANTUNES, M. J., BARON-ESQUIVIAS, G., BAUMGARTNER, H., BORGER, M. A., CARREL, T. P., DE BONIS, M., EVANGELISTA, A., FALK, V., IUNG, B., LANCELLOTTI, P., PIERARD, L., PRICE, S., SCHAFERS, H. J., SCHULER, G., STEPINSKA, J., SWEDBERG, K., TAKKENBERG, J., VON OPPELL, U. O., WINDECKER, S., ZAMORANO, J. L. & ZEMBALA, M. 2012. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J, 33, 2451-96. JULIUS, B. K., SPILLMANN, M., VASSALLI, G., VILLARI, B., EBERLI, F. R. & HESS, O. M. 1997. Angina pectoris in patients with aortic stenosis and normal coronary arteries. Mechanisms and pathophysiological concepts. Circulation, 95, 892-8. KADEN, J. J., DEMPFLE, C. E., GROBHOLZ, R., TRAN, H. T., KILIC, R., SARIKOC, A., BRUECKMANN, M., VAHL, C., HAGL, S., HAASE, K. K. & BORGGREFE, M. 2003. Interleukin-1 beta promotes matrix metalloproteinase expression and cell proliferation in calcific aortic valve stenosis. Atherosclerosis, 170, 205-11. KAHLERT, P., PAROHL, N., ALBERT, J., SCHAFER, L., REINHARDT, R., KAISER, G. M., MCDOUGALL, I., DECKER, B., PLICHT, B., ERBEL, R., EGGEBRECHT, H., LADD, M. E. & QUICK, H. H. 2012. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine. J Cardiovasc Magn Reson, 14, 21. KAKU, K., TAKEUCHI, M., TSANG, W., TAKIGIKU, K., YASUKOCHI, S., PATEL, A. R., MOR-AVI, V., LANG, R. M. & OTSUJI, Y. 2014. Age-related normal range of left ventricular strain and torsion using three-dimensional speckle-tracking echocardiography. J Am Soc Echocardiogr, 27, 55-64. KAMMERLANDER, A. A., MARZLUF, B. A., GRAF, A., BACHMANN, A., KOCHER, A., BONDERMAN, D. & MASCHERBAUER, J. 2014. Right ventricular dysfunction, but not tricuspid regurgitation, is associated with outcome late after left heart valve procedure. J Am Coll Cardiol, 64, 2633-42. KAPADIA, S. R., LEON, M. B., MAKKAR, R. R., TUZCU, E. M., SVENSSON, L. G., KODALI, S., WEBB, J. G., MACK, M. J., DOUGLAS, P. S., THOURANI, V. H., BABALIAROS, V. C., HERRMANN, H. C., SZETO, W. Y., PICHARD, A. D., WILLIAMS, M. R., FONTANA, G. P., MILLER, D. C., ANDERSON, W. N., AKIN, J. J., DAVIDSON, M. J. & SMITH, C. R. 2015. 5-year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial. Lancet, 385, 2485-91. KAPPETEIN, A. P., HEAD, S. J., GENEREUX, P., PIAZZA, N., VAN MIEGHEM, N. M., BLACKSTONE, E. H., BROTT, T. G., COHEN, D. J., CUTLIP, D. E., VAN ES, G. A., HAHN, R. T., KIRTANE, A. J., KRUCOFF, M. W., KODALI, S., MACK, M. J., MEHRAN, R., RODES-CABAU, J., VRANCKX, P., WEBB, J. G., WINDECKER, S., SERRUYS, P. W. & LEON, M. B. 2013. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Thorac Cardiovasc Surg, 145, 6-23. KEMPNY, A., DILLER, G. P., KALESCHKE, G., ORWAT, S., FUNKE, A., SCHMIDT, R., KERCKHOFF, G., GHEZELBASH, F., RUKOSUJEW, A., REINECKE, H., SCHELD, H. H. & BAUMGARTNER, H. 2012. Impact of transcatheter aortic valve implantation or surgical aortic valve replacement on right ventricular function. Heart, 98, 1299-304. KEYL, C., SCHNEIDER, J., BEYERSDORF, F., RUILE, P., SIEPE, M., PIOCH, K., SCHNEIDER, R. & JANDER, N. 2015. Right ventricular function after aortic valve replacement: a pilot study comparing surgical and transcatheter procedures using 3D echocardiography. Eur J Cardiothorac Surg. KIM, W. K., ROLF, A., LIEBETRAU, C., VAN LINDEN, A., BLUMENSTEIN, J., KEMPFERT, J., BACHMANN, G., NEF, H., HAMM, C., WALTHER, T. & MOLLMANN, H. 2014. Detection of myocardial injury by CMR after transcatheter aortic valve replacement. J Am Coll Cardiol, 64, 349-57. KOCH, J. A., POLL, L. W., GODEHARDT, E., KORBMACHER, B. & MODDER, U. 2000. Right and left ventricular volume measurements in an animal heart model in vitro: first experiences with cardiac MRI at 1.0 T. Eur Radiol, 10, 455-8. KODALI, S., PIBAROT, P., DOUGLAS, P. S., WILLIAMS, M., XU, K., THOURANI, V., RIHAL, C. S., ZAJARIAS, A., DOSHI, D., DAVIDSON, M., TUZCU, E. M., STEWART, W., WEISSMAN, N. J., SVENSSON, L., GREASON, K., MANIAR, H., MACK, M., ANWARUDDIN, S., LEON, M. B. & HAHN, R. T. 2015. Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes. Eur Heart J, 36, 449-56. KODALI, S. K., WILLIAMS, M. R., SMITH, C. R., SVENSSON, L. G., WEBB, J. G., MAKKAR, R. R., FONTANA, G. P., DEWEY, T. M., THOURANI, V. H., PICHARD, A. D., FISCHBEIN, M., SZETO, W. Y., LIM, S., GREASON, K. L., TEIRSTEIN, P. S., MALAISRIE, S. C., DOUGLAS, P. S., HAHN, R. T., WHISENANT, B., ZAJARIAS, A., WANG, D., AKIN, J. J., ANDERSON, W. N., LEON, M. B. & INVESTIGATORS, P. T. 2012. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Engl J Med, 366, 1686-95. KOUCHOUKOS, N. T., LELL, W. A., KARP, R. B. & SAMUELSON, P. N. 1979. Hemodynamic effects of aortic clamping and decompression with a temporary shunt for resection of the descending thoracic aorta. Surgery, 85, 25-30. KRAYENBUEHL, H. P., HESS, O. M., MONRAD, E. S., SCHNEIDER, J., MALL, G. & TURINA, M. 1989. Left ventricular myocardial structure in aortic valve disease before, intermediate, and late after aortic valve replacement. Circulation, 79, 744-55. KUSUNOSE, K., GOODMAN, A., PARIKH, R., BARR, T., AGARWAL, S., POPOVIC, Z. B., GRIMM, R. A., GRIFFIN, B. P. & DESAI, M. Y. 2014. Incremental prognostic value of left ventricular global longitudinal strain in patients with aortic stenosis and preserved ejection fraction. Circ Cardiovasc Imaging, 7, 938-45. KWAK, Y. L., OH, Y. J., JUNG, S. M., YOO, K. J., LEE, J. H. & HONG, Y. W. 2004. Change in right ventricular function during off-pump coronary artery bypass graft surgery. Eur J Cardiothorac Surg, 25, 572-7. LA MANNA, A., SANFILIPPO, A., CAPODANNO, D., SALEMI, A., CADONI, A., CASCONE, I., POLIZZI, G., FIGUERA, M., PITTALA, R., PRIVITERA, C. & TAMBURINO, C. 2013. Left ventricular reverse remodeling after transcatheter aortic valve implantation: a cardiovascular magnetic resonance study. J Cardiovasc Magn Reson, 15, 39. LANCELLOTTI, P., DONAL, E., MAGNE, J., O'CONNOR, K., MOONEN, M. L., COSYNS, B. & PIERARD, L. A. 2010. Impact of global left ventricular afterload on left ventricular function in asymptomatic severe aortic stenosis: a two-dimensional speckle-tracking study. Eur J Echocardiogr, 11, 537-43. LEON, M. B., PIAZZA, N., NIKOLSKY, E., BLACKSTONE, E. H., CUTLIP, D. E., KAPPETEIN, A. P., KRUCOFF, M. W., MACK, M., MEHRAN, R., MILLER, C., MOREL, M. A., PETERSEN, J., POPMA, J. J., TAKKENBERG, J. J., VAHANIAN, A., VAN ES, G. A., VRANCKX, P., WEBB, J. G., WINDECKER, S. & SERRUYS, P. W. 2011. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium. Eur Heart J, 32, 205-17. LEON, M. B., SMITH, C. R., MACK, M., MILLER, D. C., MOSES, J. W., SVENSSON, L. G., TUZCU, E. M., WEBB, J. G., FONTANA, G. P., MAKKAR, R. R., BROWN, D. L., BLOCK, P. C., GUYTON, R. A., PICHARD, A. D., BAVARIA, J. E., HERRMANN, H. C., DOUGLAS, P. S., PETERSEN, J. L., AKIN, J. J., ANDERSON, W. N., WANG, D., POCOCK, S. & INVESTIGATORS, P. T. 2010. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med, 363, 1597-607. LEON, M. B., SMITH, C. R., MACK, M. J., MAKKAR, R. R., SVENSSON, L. G., KODALI, S. K., THOURANI, V. H., TUZCU, E. M., MILLER, D. C., HERRMANN, H. C., DOSHI, D., COHEN, D. J., PICHARD, A. D., KAPADIA, S., DEWEY, T., BABALIAROS, V., SZETO, W. Y., WILLIAMS, M. R., KEREIAKES, D., ZAJARIAS, A., GREASON, K. L., WHISENANT, B. K., HODSON, R. W., MOSES, J. W., TRENTO, A., BROWN, D. L., FEARON, W. F., PIBAROT, P., HAHN, R. T., JABER, W. A., ANDERSON, W. N., ALU, M. C. & WEBB, J. G. 2016. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. LERAKIS, S., HAYEK, S. S. & DOUGLAS, P. S. 2013. Paravalvular aortic leak after transcatheter aortic valve replacement: current knowledge. Circulation, 127, 397-407. LIAKOPOULOS, O. J., KUHN, E. W., CHOI, Y. H., CHANG, W., WITTWER, T., MADERSHAHIAN, N., WASSMER, G. & WAHLERS, T. 2010. Myocardial protection in cardiac surgery patients requiring prolonged aortic cross-clamp times: a single-center evaluation of clinical outcomes comparing two blood cardioplegic strategies. J Cardiovasc Surg (Torino), 51, 895-905. LINDMAN, B. R., STEWART, W. J., PIBAROT, P., HAHN, R. T., OTTO, C. M., XU, K., DEVEREUX, R. B., WEISSMAN, N. J., ENRIQUEZ-SARANO, M., SZETO, W. Y., MAKKAR, R., MILLER, D. C., LERAKIS, S., KAPADIA, S., BOWERS, B., GREASON, K. L., MCANDREW, T. C., LEI, Y., LEON, M. B. & DOUGLAS, P. S. 2014. Early regression of severe left ventricular hypertrophy after transcatheter aortic valve replacement is associated with decreased hospitalizations. JACC Cardiovasc Interv, 7, 662-73. LINDQVIST, P., ZHAO, Y., BAJRAKTARI, G., HOLMGREN, A. & HENEIN, M. Y. 2011. Aortic valve replacement normalizes left ventricular twist function. Interact Cardiovasc Thorac Surg, 12, 701-6. LINKE, A., WENAWESER, P., GERCKENS, U., TAMBURINO, C., BOSMANS, J., BLEIZIFFER, S., BLACKMAN, D., SCHAFER, U., MULLER, R., SIEVERT, H., SONDERGAARD, L., KLUGMANN, S., HOFFMANN, R., TCHETCHE, D., COLOMBO, A., LEGRAND, V. M., BEDOGNI, F., LEPRINCE, P., SCHULER, G., MAZZITELLI, D., EFTYCHIOU, C., FRERKER, C., BOEKSTEGERS, P., WINDECKER, S., MOHR, F. W., WOITEK, F., LANGE, R., BAUERNSCHMITT, R., BRECKER, S. & INVESTIGATORS, A. S. 2014. Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study. Eur Heart J, 35, 2672-84. LOPEZ-MATTEI, J. C. & SHAH, D. J. 2013. The role of cardiac magnetic resonance in valvular heart disease. Methodist Debakey Cardiovasc J, 9, 142-8. MACK, M. J., LEON, M. B., SMITH, C. R., MILLER, D. C., MOSES, J. W., TUZCU, E. M., WEBB, J. G., DOUGLAS, P. S., ANDERSON, W. N., BLACKSTONE, E. H., KODALI, S. K., MAKKAR, R. R., FONTANA, G. P., KAPADIA, S., BAVARIA, J., HAHN, R. T., THOURANI, V. H., BABALIAROS, V., PICHARD, A., HERRMANN, H. C., BROWN, D. L., WILLIAMS, M., AKIN, J., DAVIDSON, M. J. & SVENSSON, L. G. 2015. 5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial. Lancet, 385, 2477-84. MAHADEVIA, R., BARKER, A. J., SCHNELL, S., ENTEZARI, P., KANSAL, P., FEDAK, P. W., MALAISRIE, S. C., MCCARTHY, P., COLLINS, J., CARR, J. & MARKL, M. 2014. Bicuspid aortic cusp fusion morphology alters aortic three-dimensional outflow patterns, wall shear stress, and expression of aortopathy. Circulation, 129, 673-82. MAHMOD, M., BULL, S., SUTTIE, J. J., PAL, N., HOLLOWAY, C., DASS, S., MYERSON, S. G., SCHNEIDER, J. E., DE SILVA, R., PETROU, M., SAYEED, R., WESTABY, S., CLELLAND, C., FRANCIS, J. M., ASHRAFIAN, H., KARAMITSOS, T. D. & NEUBAUER, S. 2013. Myocardial steatosis and left ventricular contractile dysfunction in patients with severe aortic stenosis. Circ Cardiovasc Imaging, 6, 808-16. MAHRHOLDT, H., WAGNER, A., JUDD, R. M., SECHTEM, U. & KIM, R. J. 2005. Delayed enhancement cardiovascular magnetic resonance assessment of non-ischaemic cardiomyopathies. Eur Heart J, 26, 1461-74. MARKL, M., CHAN, F. P., ALLEY, M. T., WEDDING, K. L., DRANEY, M. T., ELKINS, C. J., PARKER, D. W., WICKER, R., TAYLOR, C. A., HERFKENS, R. J. & PELC, N. J. 2003. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging, 17, 499-506. MARKL, M., WALLIS, W. & HARLOFF, A. 2011. Reproducibility of flow and wall shear stress analysis using flow-sensitive four-dimensional MRI. J Magn Reson Imaging, 33, 988-94. MAROULES, C. D., KHERA, A., AYERS, C., GOEL, A., PESHOCK, R. M., ABBARA, S. & KING, K. S. 2014. Cardiovascular outcome associations among cardiovascular magnetic resonance measures of arterial stiffness: the Dallas heart study. J Cardiovasc Magn Reson, 16, 33. MCGAVOCK, J. M., VICTOR, R. G., UNGER, R. H., SZCZEPANIAK, L. S., AMERICAN COLLEGE OF, P. & THE AMERICAN PHYSIOLOGICAL, S. 2006. Adiposity of the heart, revisited. Ann Intern Med, 144, 517-24. MEIMOUN, P., ELMKIES, F., BENALI, T., BOULANGER, J., ZEMIR, H., CLERC, J. & LUYCX-BORE, A. 2011. [Assessment of left ventricular twist mechanics by two-dimensional strain in severe aortic stenosis with preserved ejection fraction]. Ann Cardiol Angeiol (Paris), 60, 259-66. MELINA, G., RAJAPPAN, K., AMRANI, M., KHAGHANI, A., PENNELL, D. J. & YACOUB, M. H. 2002. Aortic distensibility after aortic root replacement assessed with cardiovascular magnetic resonance. J Heart Valve Dis, 11, 67-74; discussion 74. MEREDITH AM, I. T., WALTERS, D. L., DUMONTEIL, N., WORTHLEY, S. G., TCHETCHE, D., MANOHARAN, G., BLACKMAN, D. J., RIOUFOL, G., HILDICK-SMITH, D., WHITBOURN, R. J., LEFEVRE, T., LANGE, R., MULLER, R., REDWOOD, S., ALLOCCO, D. J. & DAWKINS, K. D. 2014. Transcatheter aortic valve replacement for severe symptomatic aortic stenosis using a repositionable valve system: 30-day primary endpoint results from the REPRISE II study. J Am Coll Cardiol, 64, 1339-48. MEREDITH, I. T., HOOD, K. L., HARATANI, N., ALLOCCO, D. J. & DAWKINS, K. D. 2012. Boston Scientific Lotus valve. EuroIntervention, 8 Suppl Q, Q70-4. MEREDITH, I. T., WORTHLEY, S. G., WHITBOURN, R. J., ANTONIS, P., MONTARELLO, J. K., NEWCOMB, A. E., LOCKWOOD, S., HARATANI, N., ALLOCCO, D. J. & DAWKINS, K. D. 2014. Transfemoral aortic valve replacement with the repositionable Lotus Valve System in high surgical risk patients: the REPRISE I study. EuroIntervention, 9, 1264-70. MERTEN, C., BEURICH, H. W., ZACHOW, D., MOSTAFA, A. E., GEIST, V., TOELG, R., RICHARDT, G. & ABDEL-WAHAB, M. 2013. Aortic regurgitation and left ventricular remodeling after transcatheter aortic valve implantation: a serial cardiac magnetic resonance imaging study. Circ Cardiovasc Interv, 6, 476-83. METAFRATZI, Z. M., EFREMIDIS, S. C., SKOPELITOU, A. S. & DE ROOS, A. 2002. The clinical significance of aortic compliance and its assessment with magnetic resonance imaging. J Cardiovasc Magn Reson, 4, 481-91. MEWTON, N., LIU, C. Y., CROISILLE, P., BLUEMKE, D. & LIMA, J. A. 2011. Assessment of myocardial fibrosis with cardiovascular magnetic resonance. J Am Coll Cardiol, 57, 891-903. MEYER, C. G., FRICK, M., LOTFI, S., ALTIOK, E., KOOS, R., KIRSCHFINK, A., LEHRKE, M., AUTSCHBACH, R. & HOFFMANN, R. 2014. Regional left ventricular function after transapical vs. transfemoral transcatheter aortic valve implantation analysed by cardiac magnetic resonance feature tracking. Eur Heart J Cardiovasc Imaging, 15, 1168-76. MILANO, A. D., FAGGIAN, G., DODONOV, M., GOLIA, G., TOMEZZOLI, A., BORTOLOTTI, U. & MAZZUCCO, A. 2012. Prognostic value of myocardial fibrosis in patients with severe aortic valve stenosis. J Thorac Cardiovasc Surg, 144, 830-7. MILLER, J. G., LI, M., MAZILU, D., HUNT, T. & HORVATH, K. A. 2015. Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement. J Thorac Cardiovasc Surg. MOAT, N. E., LUDMAN, P., DE BELDER, M. A., BRIDGEWATER, B., CUNNINGHAM, A. D., YOUNG, C. P., THOMAS, M., KOVAC, J., SPYT, T., MACCARTHY, P. A., WENDLER, O., HILDICK-SMITH, D., DAVIES, S. W., TRIVEDI, U., BLACKMAN, D. J., LEVY, R. D., BRECKER, S. J., BAUMBACH, A., DANIEL, T., GRAY, H. & MULLEN, M. J. 2011. Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry. J Am Coll Cardiol, 58, 2130-8. MONIN, J. L., QUERE, J. P., MONCHI, M., PETIT, H., BALEYNAUD, S., CHAUVEL, C., POP, C., OHLMANN, P., LELGUEN, C., DEHANT, P., TRIBOUILLOY, C. & GUERET, P. 2003. Low-gradient aortic stenosis: operative risk stratification and predictors for long-term outcome: a multicenter study using dobutamine stress hemodynamics. Circulation, 108, 319-24. MURRAY, G. 1956. Homologous aortic-valve-segment transplants as surgical treatment for aortic and mitral insufficiency. Angiology, 7, 466-71. MYERSON, S. G. 2012. Heart valve disease: investigation by cardiovascular magnetic resonance. J Cardiovasc Magn Reson, 14, 7. MYERSON, S. G., BELLENGER, N. G. & PENNELL, D. J. 2002a. Assessment of left ventricular mass by cardiovascular magnetic resonance. Hypertension, 39, 750-5. MYERSON, S. G., MONTGOMERY, H. E., WORLD, M. J. & PENNELL, D. J. 2002b. Left ventricular mass: reliability of M-mode and 2-dimensional echocardiographic formulas. Hypertension, 40, 673-8. NAGEL, E., STUBER, M., BURKHARD, B., FISCHER, S. E., SCHEIDEGGER, M. B., BOESIGER, P. & HESS, O. M. 2000. Cardiac rotation and relaxation in patients with aortic valve stenosis. Eur Heart J, 21, 582-9. NELSON, A. J., WORTHLEY, S. G., CAMERON, J. D., WILLOUGHBY, S. R., PIANTADOSI, C., CARBONE, A., DUNDON, B. K., LEUNG, M. C., HOPE, S. A., MEREDITH, I. T. & WORTHLEY, M. I. 2009. Cardiovascular magnetic resonance-derived aortic distensibility: validation and observed regional differences in the elderly. J Hypertens, 27, 535-42. NEMES, A., GALEMA, T. W., GELEIJNSE, M. L., SOLIMAN, O. I., YAP, S. C., ANWAR, A. M. & TEN CATE, F. J. 2007. Aortic valve replacement for aortic stenosis is associated with improved aortic distensibility at long-term follow-up. Am Heart J, 153, 147-51. NEMES, A., GALEMA, T. W., SOLIMAN, O. I., BOGERS, A. J., TEN CATE, F. J. & GELEIJNSE, M. L. 2009. Improved aortic distensibility after aortic homograft root replacement at long-term follow-up. Int J Cardiol, 136, 216-9. NEWTON, J. D., REDWOOD, S. & PRENDERGAST, B. D. 2015. Transcatheter aortic valve implantation: a durable treatment option in aortic stenosis? Heart, 101, 913-4. NG, A. C., DELGADO, V., BERTINI, M., VAN DER MEER, R. W., RIJZEWIJK, L. J., HOOI EWE, S., SIEBELINK, H. M., SMIT, J. W., DIAMANT, M., ROMIJN, J. A., DE ROOS, A., LEUNG, D. Y., LAMB, H. J. & BAX, J. J. 2010. Myocardial steatosis and biventricular strain and strain rate imaging in patients with type 2 diabetes mellitus. Circulation, 122, 2538-44. NIGRI, M., AZEVEDO, C. F., ROCHITTE, C. E., SCHRAIBMAN, V., TARASOUTCHI, F., POMMERANTZEFF, P. M., BRANDAO, C. M., SAMPAIO, R. O., PARGA, J. R., AVILA, L. F., SPINA, G. S. & GRINBERG, M. 2009. Contrast-enhanced magnetic resonance imaging identifies focal regions of intramyocardial fibrosis in patients with severe aortic valve disease: Correlation with quantitative histopathology. Am Heart J, 157, 361-8. NIJVELDT, R., GERMANS, T., MCCANN, G. P., BEEK, A. M. & VAN ROSSUM, A. C. 2008. Semi-quantitative assessment of right ventricular function in comparison to a 3D volumetric approach: a cardiovascular magnetic resonance study. Eur Radiol, 18, 2399-405. NISHIMURA, R. A., OTTO, C. M., BONOW, R. O., CARABELLO, B. A., ERWIN, J. P., 3RD, GUYTON, R. A., O'GARA, P. T., RUIZ, C. E., SKUBAS, N. J., SORAJJA, P., SUNDT, T. M., 3RD & THOMAS, J. D. 2014a. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol, 63, 2438-88. NISHIMURA, R. A., OTTO, C. M., BONOW, R. O., CARABELLO, B. A., ERWIN, J. P., 3RD, GUYTON, R. A., O'GARA, P. T., RUIZ, C. E., SKUBAS, N. J., SORAJJA, P., SUNDT, T. M., 3RD, THOMAS, J. D. & AMERICAN COLLEGE OF CARDIOLOGY/AMERICAN HEART ASSOCIATION TASK FORCE ON PRACTICE, G. 2014b. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol, 63, 2438-88. NKOMO, V. T., GARDIN, J. M., SKELTON, T. N., GOTTDIENER, J. S., SCOTT, C. G. & ENRIQUEZ-SARANO, M. 2006. Burden of valvular heart diseases: a population-based study. Lancet, 368, 1005-11. NWAEJIKE, N., MILLS, K., STABLES, R. & FIELD, M. 2015. Balloon aortic valvuloplasty as a bridge to aortic valve surgery for severe aortic stenosis. Interact Cardiovasc Thorac Surg, 20, 429-35. O'BRIEN, K. R., COWAN, B. R., JAIN, M., STEWART, R. A., KERR, A. J. & YOUNG, A. A. 2008. MRI phase contrast velocity and flow errors in turbulent stenotic jets. J Magn Reson Imaging, 28, 210-8. OH, J. K., LITTLE, S. H., ABDELMONEIM, S. S., REARDON, M. J., KLEIMAN, N. S., LIN, G., BACH, D., GILLAM, L., KAR, B., COSELLI, J., SENGUPTA, P. P., GREWAL, K., CHANG, J., CHANG, Y., BOULWARE, M., ADAMS, D. H., POPMA, J. J. & COREVALVE, U. S. P. T. C. I. 2015. Regression of Paravalvular Aortic Regurgitation and Remodeling of Self-Expanding Transcatheter Aortic Valve: An Observation From the CoreValve U.S. Pivotal Trial. JACC Cardiovasc Imaging, 8, 1364-75. OKADA, D. R., RAHMOUNI, H. W., HERRMANN, H. C., BAVARIA, J. E., FORFIA, P. R. & HAN, Y. 2014. Assessment of right ventricular function by transthoracic echocardiography following aortic valve replacement. Echocardiography, 31, 552-7. OLIVER, J. J. & WEBB, D. J. 2003. Noninvasive assessment of arterial stiffness and risk of atherosclerotic events. Arterioscler Thromb Vasc Biol, 23, 554-66. OZKAN, A., KAPADIA, S., TUZCU, M. & MARWICK, T. H. 2011. Assessment of left ventricular function in aortic stenosis. Nat Rev Cardiol, 8, 494-501. PAELINCK, B. P., VAN HERCK, P. L., RODRIGUS, I., CLAEYS, M. J., LABORDE, J. C., PARIZEL, P. M., VRINTS, C. J. & BOSMANS, J. M. 2011. Comparison of magnetic resonance imaging of aortic valve stenosis and aortic root to multimodality imaging for selection of transcatheter aortic valve implantation candidates. Am J Cardiol, 108, 92-8. PEGG, T. J., SELVANAYAGAM, J. B., KARAMITSOS, T. D., ARNOLD, R. J., FRANCIS, J. M., NEUBAUER, S. & TAGGART, D. P. 2008. Effects of off-pump versus on-pump coronary artery bypass grafting on early and late right ventricular function. Circulation, 117, 2202-10. PIAZZA, N., GRUBE, E., GERCKENS, U., DEN HEIJER, P., LINKE, A., LUHA, O., RAMONDO, A., USSIA, G., WENAWESER, P., WINDECKER, S., LABORDE, J. C., DE JAEGERE, P. & SERRUYS, P. W. 2008. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention, 4, 242-9. PIBAROT, P. & DUMESNIL, J. G. 2010. Longitudinal myocardial shortening in aortic stenosis: ready for prime time after 30 years of research? Heart, 96, 95-6. PIBAROT, P., HAHN, R. T., WEISSMAN, N. J. & MONAGHAN, M. J. 2015. Assessment of paravalvular regurgitation following TAVR: a proposal of unifying grading scheme. JACC Cardiovasc Imaging, 8, 340-60. PINZANI, A., DE GEVIGNEY, G., PINZANI, V., NINET, J., MILON, H. & DELAHAYE, J. P. 1993. [Pre- and postoperative right cardiac insufficiency in patients with mitral or mitral-aortic valve diseases]. Arch Mal Coeur Vaiss, 86, 27-34. POPMA, J. J., ADAMS, D. H., REARDON, M. J., YAKUBOV, S. J., KLEIMAN, N. S., HEIMANSOHN, D., HERMILLER, J., JR., HUGHES, G. C., HARRISON, J. K., COSELLI, J., DIEZ, J., KAFI, A., SCHREIBER, T., GLEASON, T. G., CONTE, J., BUCHBINDER, M., DEEB, G. M., CARABELLO, B., SERRUYS, P. W., CHENOWETH, S. & OH, J. 2014. Transcatheter Aortic Valve Replacement Using A Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis at Extreme Risk for Surgery. J Am Coll Cardiol. POULIN, F., CARASSO, S., HORLICK, E. M., RAKOWSKI, H., LIM, K. D., FINN, H., FEINDEL, C. M., GREUTMANN, M., OSTEN, M. D., CUSIMANO, R. J. & WOO, A. 2014. Recovery of left ventricular mechanics after transcatheter aortic valve implantation: effects of baseline ventricular function and postprocedural aortic regurgitation. J Am Soc Echocardiogr, 27, 1133-42. PUENTES, M., MESA, D., RUIZ ORTIZ, M., DELGADO, M., MAZUELOS, F. & SUAREZ DE LEZO, J. 2012. Changes in right ventricular systolic function after transcatheter aortic valve implantation assessed by two-dimensional speckle tracking echocardiography. Rev Esp Cardiol (Engl Ed), 65, 964-5. QUARTO, C., DWECK, M. R., MURIGU, T., JOSHI, S., MELINA, G., ANGELONI, E., PRASAD, S. K. & PEPPER, J. R. 2012. Late gadolinium enhancement as a potential marker of increased perioperative risk in aortic valve replacement. Interact Cardiovasc Thorac Surg, 15, 45-50. QUICK, S., SPEISER, U., PFLUECKE, C., YOUSSEF, A., SVERIC, K., STRASSER, R. & IBRAHIM, K. 2013. Aortic stenosis: right and left ventricular function in the early postprocedural phase. Comparison between transcatheter and surgical aortic valve implantation. Acta Cardiol, 68, 583-9. RADER, F., SACHDEV, E., ARSANJANI, R. & SIEGEL, R. J. 2015. Left ventricular hypertrophy in valvular aortic stenosis: mechanisms and clinical implications. Am J Med, 128, 344-52. RAJAMANNAN, N. M., EVANS, F. J., AIKAWA, E., GRANDE-ALLEN, K. J., DEMER, L. L., HEISTAD, D. D., SIMMONS, C. A., MASTERS, K. S., MATHIEU, P., O'BRIEN, K. D., SCHOEN, F. J., TOWLER, D. A., YOGANATHAN, A. P. & OTTO, C. M. 2011. Calcific aortic valve disease: not simply a degenerative process: A review and agenda for research from the National Heart and Lung and Blood Institute Aortic Stenosis Working Group. Executive summary: Calcific aortic valve disease-2011 update. Circulation, 124, 1783-91. RAJAPPAN, K., RIMOLDI, O. E., CAMICI, P. G., BELLENGER, N. G., PENNELL, D. J. & SHERIDAN, D. J. 2003. Functional changes in coronary microcirculation after valve replacement in patients with aortic stenosis. Circulation, 107, 3170-5. REARDON, M. J., ADAMS, D. H., KLEIMAN, N. S., YAKUBOV, S. J., COSELLI, J. S., DEEB, G. M., GLEASON, T. G., LEE, J. S., HERMILLER, J. B., JR., CHETCUTI, S., HEISER, J., MERHI, W., ZORN, G. L., 3RD, TADROS, P., ROBINSON, N., PETROSSIAN, G., HUGHES, G. C., HARRISON, J. K., MAINI, B., MUMTAZ, M., CONTE, J. V., RESAR, J. R., AHARONIAN, V., PFEFFER, T., OH, J. K., QIAO, H. & POPMA, J. J. 2015. 2-Year Outcomes in Patients Undergoing Surgical or Self-Expanding Transcatheter Aortic Valve Replacement. J Am Coll Cardiol, 66, 113-21. RIBEIRO, H. B., LE VEN, F., LAROSE, E., DAHOU, A., NOMBELA-FRANCO, L., URENA, M., ALLENDE, R., AMAT-SANTOS, I., RICAPITO MDE, L., THEBAULT, C., CLAVEL, M. A., DELAROCHELLIERE, R., DOYLE, D., DUMONT, E., DUMESNIL, J. G., PIBAROT, P. & RODES-CABAU, J. 2014. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation. Heart, 100, 1924-32. RIPLEY, D. P., MOTWANI, M., PLEIN, S. & GREENWOOD, J. P. 2014. Established and emerging cardiovascular magnetic resonance techniques for the assessment of stable coronary heart disease and acute coronary syndromes. Quant Imaging Med Surg, 4, 330-44. RIPLEY, D. P., NEGROU, K., OLIVER, J. J., WORTHY, G., STRUTHERS, A. D., PLEIN, S. & GREENWOOD, J. P. 2015. Aortic remodelling following the treatment and regression of hypertensive left ventricular hypertrophy: a cardiovascular magnetic resonance study. Clin Exp Hypertens, 37, 308-16. RODES-CABAU, J., WEBB, J. G., CHEUNG, A., YE, J., DUMONT, E., FEINDEL, C. M., OSTEN, M., NATARAJAN, M. K., VELIANOU, J. L., MARTUCCI, G., DEVARENNES, B., CHISHOLM, R., PETERSON, M. D., LICHTENSTEIN, S. V., NIETLISPACH, F., DOYLE, D., DELAROCHELLIERE, R., TEOH, K., CHU, V., DANCEA, A., LACHAPELLE, K., CHEEMA, A., LATTER, D. & HORLICK, E. 2010. Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. J Am Coll Cardiol, 55, 1080-90. ROSS, D. N. 1962. Homograft replacement of the aortic valve. Lancet, 2, 487. ROSS, J., JR. 1976. Afterload mismatch and preload reserve: a conceptual framework for the analysis of ventricular function. Prog Cardiovasc Dis, 18, 255-64. ROSS, J., JR. & BRAUNWALD, E. 1968. Aortic stenosis. Circulation, 38, 61-7. ROST, C., KORDER, S., WASMEIER, G., WU, M., KLINGHAMMER, L., FLACHSKAMPF, F. A., DANIEL, W. G. & VOIGT, J. U. 2010. Sequential changes in myocardial function after valve replacement for aortic stenosis by speckle tracking echocardiography. Eur J Echocardiogr, 11, 584-9. RUPARELIA, N. & PRENDERGAST, B. D. 2015. TAVI in 2015: who, where and how? Heart, 101, 1422-31. SALAUN, E., JACQUIER, A., THERON, A., GIORGI, R., LAMBERT, M., JAUSSAUD, N., HUBERT, S., COLLART, F., BONNET, J. L., HABIB, G., CUISSET, T. & GRISOLI, D. 2015. Value of CMR in quantification of paravalvular aortic regurgitation after TAVI. Eur Heart J Cardiovasc Imaging. SALIS, S., MAZZANTI, V. V., MERLI, G., SALVI, L., TEDESCO, C. C., VEGLIA, F. & SISILLO, E. 2008. Cardiopulmonary bypass duration is an independent predictor of morbidity and mortality after cardiac surgery. J Cardiothorac Vasc Anesth, 22, 814-22. SANDSTEDE, J. J., JOHNSON, T., HARRE, K., BEER, M., HOFMANN, S., PABST, T., KENN, W., VOELKER, W., NEUBAUER, S. & HAHN, D. 2002. Cardiac systolic rotation and contraction before and after valve replacement for aortic stenosis: a myocardial tagging study using MR imaging. AJR Am J Roentgenol, 178, 953-8. SANNINO, A., GARGIULO, G., SCHIATTARELLA, G. G., BREVETTI, L., PERRINO, C., STABILE, E., LOSI, M. A., TOSCANO, E., GIUGLIANO, G., SCUDIERO, F., CHIACCHIO, E., TRIMARCO, B. & ESPOSITO, G. 2014. Increased mortality after transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and low ejection fraction: a meta-analysis of 6898 patients. Int J Cardiol, 176, 32-9. SANZ, J. & DANGAS, G. 2014. Myocardial damage after TAVR assessed with CMR: a new piece in a puzzle? J Am Coll Cardiol, 64, 358-60. SCHMIDTKE, C., BECHTEL, J., HUEPPE, M., NOETZOLD, A. & SIEVERS, H. H. 2000. Size and distensibility of the aortic root and aortic valve function after different techniques of the ross procedure. J Thorac Cardiovasc Surg, 119, 990-7. SCHULZ-MENGER, J., BLUEMKE, D. A., BREMERICH, J., FLAMM, S. D., FOGEL, M. A., FRIEDRICH, M. G., KIM, R. J., VON KNOBELSDORFF-BRENKENHOFF, F., KRAMER, C. M., PENNELL, D. J., PLEIN, S. & NAGEL, E. 2013. Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) board of trustees task force on standardized post processing. J Cardiovasc Magn Reson, 15, 35. SENGUPTA, P. P., TAJIK, A. J., CHANDRASEKARAN, K. & KHANDHERIA, B. K. 2008. Twist mechanics of the left ventricle: principles and application. JACC Cardiovasc Imaging, 1, 366-76. SHAH, A. S., CHIN, C. W., VASSILIOU, V., COWELL, S. J., DORIS, M., KWOK, T. C., SEMPLE, S., ZAMVAR, V., WHITE, A. C., MCKILLOP, G., BOON, N. A., PRASAD, S. K., MILLS, N. L., NEWBY, D. E. & DWECK, M. R. 2014. Left ventricular hypertrophy with strain and aortic stenosis. Circulation, 130, 1607-16. SHERIF, M. A., ABDEL-WAHAB, M., BEURICH, H. W., STOCKER, B., ZACHOW, D., GEIST, V., TOLG, R. & RICHARDT, G. 2011. Haemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using cardiovascular magnetic resonance. EuroIntervention, 7, 57-63. SINGH, A., FORD, I., GREENWOOD, J. P., KHAN, J. N., UDDIN, A., BERRY, C., NEUBAUER, S., PRENDERGAST, B., JEROSCH-HEROLD, M., WILLIAMS, B., SAMANI, N. J. & MCCANN, G. P. 2013. Rationale and design of the PRognostic Importance of MIcrovascular Dysfunction in asymptomatic patients with Aortic Stenosis (PRIMID-AS): a multicentre observational study with blinded investigations. BMJ Open, 3, e004348. SINGH, A., STEADMAN, C. D., KHAN, J. N., HORSFIELD, M. A., BEKELE, S., NAZIR, S. A., KANAGALA, P., MASCA, N. G., CLARYSSE, P. & MCCANN, G. P. 2015. Intertechnique agreement and interstudy reproducibility of strain and diastolic strain rate at 1.5 and 3 Tesla: a comparison of feature-tracking and tagging in patients with aortic stenosis. J Magn Reson Imaging, 41, 1129-37. SINGH, A., STEADMAN, C. D. & MCCANN, G. P. 2014. Advances in the understanding of the pathophysiology and management of aortic stenosis: role of novel imaging techniques. Can J Cardiol, 30, 994-1003. SINNING, J. M., HAMMERSTINGL, C., VASA-NICOTERA, M., ADENAUER, V., LEMA CACHIGUANGO, S. J., SCHEER, A. C., HAUSEN, S., SEDAGHAT, A., GHANEM, A., MULLER, C., GRUBE, E., NICKENIG, G. & WERNER, N. 2012. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. J Am Coll Cardiol, 59, 1134-41. SINNING, J. M., VASA-NICOTERA, M., CHIN, D., HAMMERSTINGL, C., GHANEM, A., BENCE, J., KOVAC, J., GRUBE, E., NICKENIG, G. & WERNER, N. 2013. Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement. J Am Coll Cardiol, 62, 11-20. SMITH, C. R., LEON, M. B., MACK, M. J., MILLER, D. C., MOSES, J. W., SVENSSON, L. G., TUZCU, E. M., WEBB, J. G., FONTANA, G. P., MAKKAR, R. R., WILLIAMS, M., DEWEY, T., KAPADIA, S., BABALIAROS, V., THOURANI, V. H., CORSO, P., PICHARD, A. D., BAVARIA, J. E., HERRMANN, H. C., AKIN, J. J., ANDERSON, W. N., WANG, D., POCOCK, S. J. & INVESTIGATORS, P. T. 2011. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med, 364, 2187-98. SORAJJA, P. & PEDERSEN, W. 2014. Next-generation transcatheter aortic valve replacement: evolution of a revolution. J Am Coll Cardiol, 64, 1349-51. SPETHMANN, S., DREGER, H., SCHATTKE, S., BALDENHOFER, G., SAGHABALYAN, D., STANGL, V., LAULE, M., BAUMANN, G., STANGL, K. & KNEBEL, F. 2012. Doppler haemodynamics and effective orifice areas of Edwards SAPIEN and CoreValve transcatheter aortic valves. Eur Heart J Cardiovasc Imaging, 13, 690-6. STAHLI, B. E., MAIER, W., CORTI, R., LUSCHER, T. F., JENNI, R. & TANNER, F. C. 2013. Aortic regurgitation after transcatheter aortic valve implantation: mechanisms and implications. Cardiovasc Diagn Ther, 3, 15-22. STANKOVIC, Z., ALLEN, B. D., GARCIA, J., JARVIS, K. B. & MARKL, M. 2014. 4D flow imaging with MRI. Cardiovasc Diagn Ther, 4, 173-92. STEADMAN, C. D., JEROSCH-HEROLD, M., GRUNDY, B., RAFELT, S., NG, L. L., SQUIRE, I. B., SAMANI, N. J. & MCCANN, G. P. 2012. Determinants and functional significance of myocardial perfusion reserve in severe aortic stenosis. JACC Cardiovasc Imaging, 5, 182-9. STEFANADIS, C., VLACHOPOULOS, C., KARAYANNACOS, P., BOUDOULAS, H., STRATOS, C., FILIPPIDES, T., AGAPITOS, M. & TOUTOUZAS, P. 1995. Effect of vasa vasorum flow on structure and function of the aorta in experimental animals. Circulation, 91, 2669-78. STOKLAND, O., MILLER, M. M., ILEBEKK, A. & KIIL, F. 1980. Mechanism of hemodynamic responses to occlusion of the descending thoracic aorta. Am J Physiol, 238, H423-9. STUBER, M., SCHEIDEGGER, M. B., FISCHER, S. E., NAGEL, E., STEINEMANN, F., HESS, O. M. & BOESIGER, P. 1999. Alterations in the local myocardial motion pattern in patients suffering from pressure overload due to aortic stenosis. Circulation, 100, 361-8. SWOBODA, P. P., LARGHAT, A., ZAMAN, A., FAIRBAIRN, T. A., MOTWANI, M., GREENWOOD, J. P. & PLEIN, S. 2014. Reproducibility of myocardial strain and left ventricular twist measured using complementary spatial modulation of magnetization. J Magn Reson Imaging, 39, 887-94. TAMBORINI, G., MURATORI, M., BRUSONI, D., CELESTE, F., MAFFESSANTI, F., CAIANI, E. G., ALAMANNI, F. & PEPI, M. 2009. Is right ventricular systolic function reduced after cardiac surgery? A two- and three-dimensional echocardiographic study. Eur J Echocardiogr, 10, 630-4. TAMBURINO, C., CAPODANNO, D., RAMONDO, A., PETRONIO, A. S., ETTORI, F., SANTORO, G., KLUGMANN, S., BEDOGNI, F., MAISANO, F., MARZOCCHI, A., POLI, A., ANTONIUCCI, D., NAPODANO, M., DE CARLO, M., FIORINA, C. & USSIA, G. P. 2011. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation, 123, 299-308. THADEN, J. J., NKOMO, V. T. & ENRIQUEZ-SARANO, M. 2014. The global burden of aortic stenosis. Prog Cardiovasc Dis, 56, 565-71. TRAUZEDDEL, R. F., LOBE, U., BARKER, A. J., GELSINGER, C., BUTTER, C., MARKL, M., SCHULZ-MENGER, J. & VON KNOBELSDORFF-BRENKENHOFF, F. 2015. Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement. Int J Cardiovasc Imaging. UDDIN, A., FAIRBAIRN, T. A., DJOUKHADER, I. K., IGRA, M., KIDAMBI, A., MOTWANI, M., HERZOG, B., RIPLEY, D. P., MUSA, T. A., GODDARD, A. J., BLACKMAN, D. J., PLEIN, S. & GREENWOOD, J. P. 2015. Consequence of cerebral embolism after transcatheter aortic valve implantation compared with contemporary surgical aortic valve replacement: effect on health-related quality of life. Circ Cardiovasc Interv, 8, e001913. UNSWORTH, B., CASULA, R. P., YADAV, H., BARUAH, R., HUGHES, A. D., MAYET, J. & FRANCIS, D. P. 2013. Contrasting effect of different cardiothoracic operations on echocardiographic right ventricular long axis velocities, and implications for interpretation of post-operative values. Int J Cardiol, 165, 151-60. UNSWORTH, B., FRANCIS, D. P. & MAYET, J. 2014. RE: impact of transcatheter aortic valve implantation or surgical aortic valve replacement on right ventricular function. Heart, 100, 180. USSIA, G. P., BARBANTI, M., PETRONIO, A. S., TARANTINI, G., ETTORI, F., COLOMBO, A., VIOLINI, R., RAMONDO, A., SANTORO, G., KLUGMANN, S., BEDOGNI, F., MAISANO, F., MARZOCCHI, A., POLI, A., DE CARLO, M., NAPODANO, M., FIORINA, C., DE MARCO, F., ANTONIUCCI, D., DE CILLIS, E., CAPODANNO, D. & TAMBURINO, C. 2012. Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis. Eur Heart J, 33, 969-76. VAHANIAN, A., ALFIERI, O., AL-ATTAR, N., ANTUNES, M., BAX, J., CORMIER, B., CRIBIER, A., DE JAEGERE, P., FOURNIAL, G., KAPPETEIN, A. P., KOVAC, J., LUDGATE, S., MAISANO, F., MOAT, N., MOHR, F., NATAF, P., PIERARD, L., POMAR, J. L., SCHOFER, J., TORNOS, P., TUZCU, M., VAN HOUT, B., VON SEGESSER, L. K. & WALTHER, T. 2008. Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J, 29, 1463-70. VAHANIAN, A., ALFIERI, O., ANDREOTTI, F., ANTUNES, M. J., BARON-ESQUIVIAS, G., BAUMGARTNER, H., BORGER, M. A., CARREL, T. P., DE BONIS, M., EVANGELISTA, A., FALK, V., LUNG, B., LANCELLOTTI, P., PIERARD, L., PRICE, S., SCHAFERS, H. J., SCHULER, G., STEPINSKA, J., SWEDBERG, K., TAKKENBERG, J., VON OPPELL, U. O., WINDECKER, S., ZAMORANO, J. L., ZEMBALA, M., GUIDELINES, E. S. C. C. F. P., JOINT TASK FORCE ON THE MANAGEMENT OF VALVULAR HEART DISEASE OF THE EUROPEAN SOCIETY OF, C. & EUROPEAN ASSOCIATION FOR CARDIO-THORACIC, S. 2012. Guidelines on the management of valvular heart disease (version 2012): the Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg, 42, S1-44. VAQUETTE, B., CORBINEAU, H., LAURENT, M., LELONG, B., LANGANAY, T., DE PLACE, C., FROGER-BOMPAS, C., LECLERCQ, C., DAUBERT, C. & LEGUERRIER, A. 2005. Valve replacement in patients with critical aortic stenosis and depressed left ventricular function: predictors of operative risk, left ventricular function recovery, and long term outcome. Heart, 91, 1324-9. VAVURANAKIS, M., VRACHATIS, D. A., BOUDOULAS, H., PAPAIOANNOU, T. G., MOLDOVAN, C., KARIORI, M. G., KALOGERAS, K. I., PIETRI, P. G., TENTOLOURIS, C. & STEFANADIS, C. 2012. Effect of transcatheter aortic valve implantation on the ascending aorta's elasticity. Clin Res Cardiol, 101, 895-9. VIZZARDI, E., D'ALOIA, A., FIORINA, C., BUGATTI, S., PARRINELLO, G., DE CARLO, M., GIANNINI, C., DI BELLO, V., PETRONIO, A. S., CURELLO, S., ETTORI, F. & DEI CAS, L. 2012. Early regression of left ventricular mass associated with diastolic improvement after transcatheter aortic valve implantation. J Am Soc Echocardiogr, 25, 1091-8. VLACHOPOULOS, C., AZNAOURIDIS, K. & STEFANADIS, C. 2010. Prediction of cardiovascular events and all-cause mortality with arterial stiffness: a systematic review and meta-analysis. J Am Coll Cardiol, 55, 1318-27. VON KNOBELSDORFF-BRENKENHOFF, F., TRAUZEDDEL, R. F., BARKER, A. J., GRUETTNER, H., MARKL, M. & SCHULZ-MENGER, J. 2014. Blood flow characteristics in the ascending aorta after aortic valve replacement--a pilot study using 4D-flow MRI. Int J Cardiol, 170, 426-33. WALTHER, T., BLUMENSTEIN, J., VAN LINDEN, A. & KEMPFERT, J. 2012. Contemporary management of aortic stenosis: surgical aortic valve replacement remains the gold standard. Heart, 98 Suppl 4, iv23-9. WANG, B., CHEN, H., SHU, X., HONG, T., LAI, H., WANG, C. & CHENG, L. 2013. Emerging role of echocardiographic strain/strain rate imaging and twist in systolic function evaluation and operative procedure in patients with aortic stenosis. Interact Cardiovasc Thorac Surg, 17, 384-91. WEBB, J. G., CHANDAVIMOL, M., THOMPSON, C. R., RICCI, D. R., CARERE, R. G., MUNT, B. I., BULLER, C. E., PASUPATI, S. & LICHTENSTEIN, S. 2006. Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation, 113, 842-50. WEBB, J. G. & WOOD, D. A. 2012. Current status of transcatheter aortic valve replacement. J Am Coll Cardiol, 60, 483-92. WEIDEMANN, F., HERRMANN, S., STORK, S., NIEMANN, M., FRANTZ, S., LANGE, V., BEER, M., GATTENLOHNER, S., VOELKER, W., ERTL, G. & STROTMANN, J. M. 2009. Impact of myocardial fibrosis in patients with symptomatic severe aortic stenosis. Circulation, 120, 577-84. WENAWESER, P. & O'SULLIVAN, C. J. 2012. Aortic stenosis and the right heart at risk: is transcatheter aortic valve implantation the better option? Heart, 98, 1265-6. YOUNG, A. A. & COWAN, B. R. 2012. Evaluation of left ventricular torsion by cardiovascular magnetic resonance. J Cardiovasc Magn Reson, 14, 49. ZHAO, Y., LINDQVIST, P., NILSSON, J., HOLMGREN, A., NASLUND, U. & HENEIN, M. Y. 2011. Trans-catheter aortic valve implantation--early recovery of left and preservation of right ventricular function. Interact Cardiovasc Thorac Surg, 12, 35-9."],"dcterms:accessrights":["public"],"dc:title":["Transcatheter and Surgical Aortic Valve Replacement for Severe Aortic Stenosis: Insights from Cardiovascular Magnetic Resonance Imaging"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:17:45Z"}