{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:16210"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:16210","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Next generation of atraumatic laparoscopic instruments through analysis of the instrument-tissue interface","abstract":"Mechanically induced (or iatrogenic) bowel injury from the use of laparoscopic instruments can result in devastating effects on patient outcomes both during and after surgery. The aim of this work was to investigate exactly how colonic tissue behaves both mechanically and structurally when it is subjected to a mechanical load. Analysis of force application in laparoscopic surgery is critical to understanding the nature of the instrument-tissue interaction. The development of a novel method of both histological analysis and mechanical analysis (by which the tool-tissue interaction can be characterised) has evolved through this thesis. Mechanical and histological analysis was undertaken to quantify the instrument-tissue interaction in laparoscopic surgery. This was done in both ex vivo and in vivo experiments, using an indentation method and laparoscopic instrument respectively, in porcine tissue. Mechanical stress was applied to the colon by indentation applied using the Modular Universal Surface Tester (MUST) (FalexTM Tribology USA) in ex vivo experiments to mechanically characterise the response of tissue to mechanical loading. Histological analysis was performed to examine the architecture of the tissue after loading. In vivo analysis of colon grasping was then performed to characterise grasper damage both mechanically and histologically. A mechanical measure of energy input into the tissue has been linked to consistent histological damage, above a 50 N grasping force and a loading input of 300 N.s This work has successfully identified specific loading conditions that result in tissue injury and is the first to make a link between the mechanical analyses of tissue manipulation with change to the architecture of the tissue.","abstract_html":"Mechanically induced (or iatrogenic) bowel injury from the use of laparoscopic instruments can result in devastating effects on patient outcomes both during and after surgery. The aim of this work was to investigate exactly how colonic tissue behaves both mechanically and structurally when it is subjected to a mechanical load. Analysis of force application in laparoscopic surgery is critical to understanding the nature of the instrument-tissue interaction. The development of a novel method of both histological analysis and mechanical analysis (by which the tool-tissue interaction can be characterised) has evolved through this thesis. Mechanical and histological analysis was undertaken to quantify the instrument-tissue interaction in laparoscopic surgery. This was done in both ex vivo and in vivo experiments, using an indentation method and laparoscopic instrument respectively, in porcine tissue. Mechanical stress was applied to the colon by indentation applied using the Modular Universal Surface Tester (MUST) (FalexTM Tribology USA) in ex vivo experiments to mechanically characterise the response of tissue to mechanical loading. Histological analysis was performed to examine the architecture of the tissue after loading. In vivo analysis of colon grasping was then performed to characterise grasper damage both mechanically and histologically. A mechanical measure of energy input into the tissue has been linked to consistent histological damage, above a 50 N grasping force and a loading input of 300 N.s This work has successfully identified specific loading conditions that result in tissue injury and is the first to make a link between the mechanical analyses of tissue manipulation with change to the architecture of the tissue.","abstract_has_math":false,"creators":["Barrie, Jenifer"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Neville, Anne","Calmer, Peter R.","Jayne, David G.","Pavitt, Sue"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-02","date_published":"2017-02","updated_at":"2026-11-18T22:19:32Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.703364"],"render_values":[{"text":"uk.bl.ethos.703364","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/16210/1/Corrected%20thesis_final.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A16210","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Neville, Anne","Calmer, Peter R.","Jayne, David G.","Pavitt, Sue"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Bowel Diseases Research Fund"]},{"key":"dc:creator","label":"Author","values":["Barrie, Jenifer"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-02-03"]},{"key":"dc:date.issued","label":"Date","values":["2017-02"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Engineering Thermofluids, Surfaces & Interfaces (iETSI) (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/16210/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. Burns E, Currie A, Bottle A, Aylin P, Darzi A, Faiz O. Minimal‐access colorectal surgery is associated with fewer adhesion related admissions than open surgery. British Journal of Surgery. 2013;100(1):152-9. 2. Yamada T, Okabayashi K, Hasegawa H, Tsuruta M, Yoo JH, Seishima R, et al. Meta‐analysis of the risk of small bowel obstruction following open or laparoscopic colorectal surgery. British Journal of Surgery. 2016. 3. Aquina CT, Probst CP, Becerra AZ, Iannuzzi JC, Hensley BJ, Noyes K, et al. Missed opportunity: laparoscopic colorectal resection is associated with lower incidence of small bowel obstruction compared to an open approach. Annals of Surgery. 2016;264(1):127-34. 4. Wang C-L, Qu G, Xu H-W. The short-and long-term outcomes of laparoscopic versus open surgery for colorectal cancer: a meta-analysis. International Journal of Colorectal Disease. 2014;29(3):309-20. 5. Smith A, Smith J, Jayne D. Telerobotics: Surgery for the 21st century. Surgery. 2006;24(2):74-8. 6. Lanfranco A, Castellanos A, Desai J, Meyers W. Robotic surgery:A current perspective. Annals of Surgery. 2004;239(1):14-21. 7. Turley RS, Barbas AS, Lidsky ME, Mantyh CR, Migaly J, Scarborough JE. Laparoscopic versus open Hartmann procedure for the emergency treatment of diverticulitis: a propensity-matched analysis. Diseases of the Colon & Rectum. 2013;56(1):72-82. 8. Ballian N, Weisensel N, Rajamanickam V, Foley EF, Heise CP, Harms BA, et al. Comparable postoperative morbidity and mortality after laparoscopic and open emergent restorative colectomy: outcomes from the ACS NSQIP. World J Surg. 2012;36(10):2488-96. 9. Tierris I, Mavrantonis C, Stratoulias C, Panousis G, Mpetsou A, Kalochristianakis N. Laparoscopy for acute small bowel obstruction: indication or contraindication? Surgical Endoscopy. 2011;25(2):531-5. 10. Bertleff MJ, Lange JF. Laparoscopic correction of perforated peptic ulcer: first choice? A review of literature. Surgical Endoscopy. 2010;24(6):1231-9. 11. Gash K, Chambers W, Ghosh A, Dixon A. The role of laparoscopic surgery for the management of acute large bowel obstruction. Colorectal Disease. 2011;13(3):263-6. 12. Royds J, O’Riordan J, Eguare E, O’Riordan D, Neary P. Laparoscopic surgery for complicated diverticular disease: a single‐centre experience. Colorectal Disease. 2012;14(10):1248-54. 13. Vettoretto N, Gazzola L, Giovanetti M. Emergency Laparoscopic Ileocecal Resection for Crohn's Acute Obstruction. JSLS: Journal of the Society of Laparoendoscopic Surgeons. 2013;17(3):499-502. 14. O’Connor DB, Winter DC. The role of laparoscopy in the management of acute small-bowel obstruction: a review of over 2,000 cases. Surgical Endoscopy. 2012;26(1):12-7. 15. Kyung MS, Choi JS, Lee JH, Jung US, Lee KW. Laparoscopic management of complications in gynecologic laparoscopic surgery: a 5-year experience in a single center. Journal of Minimally Invasive Gynecology. 2008;15(6):689-94. 16. Suter M, Zermatten P, Halkic N, Martinet O, Bettschart V. Laparoscopic management of mechanical small bowel obstruction. Surg Endosc. 2000;14(5):478-83. 17. Szomstein S, Menzo EL, Simpfendorfer C, Zundel N, Rosenthal RJ. Laparoscopic lysis of adhesions. World Journal of Surgery. 2006;30(4):535-40. 18. Forbes S, Eskicioglu C, McLeod R, Okrainec A. Meta analysis of randomized controlled trials comparing open and laparoscopic ventral and incisional hernia repair with mesh. British Journal of Surgery. 2009;96(8):851-8. 19. Makino T, Milsom JW, Lee SW. Feasibility and safety of single-incision laparoscopic colectomy: a systematic review. Annals of Surgery. 2012;255(4):667-76. 20. Fung AY, Aly E. Systematic review of single incision laparoscopic colonic surgery. British Journal of Surgery. 2012;99(10):1353-64. 21. Haber G-P, White MA, Autorino R, Escobar PF, Kroh MD, Chalikonda S, et al. Novel robotic da Vinci instruments for laparoendoscopic single-site surgery. Urology. 2010;76(6):1279-82. 22. Kennedy GD, Heise C, Rajamanickam V, Harms B, Foley EF. Laparoscopy decreases postoperative complication rates after abdominal colectomy: results from the national surgical quality improvement program. Annals of Surgery. 2009;249(4):596-601. 23. Barrie J, Jayne DG, Wright J, Murray CJC, Collinson FJ, Pavitt SH. Attaining Surgical Competency and Its Implications in Surgical Clinical Trial Design: A Systematic Review of the Learning Curve in Laparoscopic and Robot-Assisted Laparoscopic Colorectal Cancer Surgery. Annals of Surgical Oncology. 2014;21(3): 829-840. 24. Van der Voort M, Heijnsdijk E, Gouma D. Bowel injury as a complication of laparoscopy. British Journal of Surgery. 2004;91(10):1253-8. 25. Sammour T, Kahokehr A, Srinivasa S, Bissett IP, Hill AG. Laparoscopic colorectal surgery is associated with a higher intraoperative complication rate than open surgery. Annals of Surgery. 2011;253(1):35-43. 26. Tang BB, Hanna GB, Joice PP, Cuschieri AA. Identification and categorization of technical errors by observational clinical human reliability assessment (ochra) during laparoscopic cholecystectomy. Archives of Surgery. 2004;139(11):1215-20. 27. Levy B, De Guara J, Willson P, Soon Y, Kent A, Rockall T. Bladder injuries in emergency/expedited laparoscopic surgery in the absence of previous surgery: a case series. Annals of the Royal College of Surgeons of England. 2012;94(3):e118-20. 28. Tian Y-F, Lin Y-S, Lu C-L, Chia C-C, Huang K-F, Shih T-Y, et al. Major complications of operative gynecologic laparoscopy in southern Taiwan: a follow-up study. Journal of Minimally Invasive Gynecology. 2007;14(3):284-92. 29. Chung BI, Desai MM, Gill IS. Management of intraoperative splenic injury during laparoscopic urological surgery. BJU International. 2011;108(4):572-6. 30. Nagtegaal I, Cornelis J, van der Velde E, van der Worp E, Kapiteijn E, Quirke P, et al. Macroscopic evaluation of rectal cancer resection specimen: clinical significance of the pathologist in quality control. Journal of Clinical Oncology 2002;20(7):1729-34 31. West N, Hohenberger W, Weber K, Perrakis A, Finan P, P. Q. Complete mesocolic excision with central vascular ligation produces an oncologically superior specimen compared with standard surgery for carcinoma of the colon. Journal of Clinical Oncology 2010;28(2):272-8. 32. West N, Morris E, Rotimi O, Cairns A, Finan P, Quirke P. Pathology grading of colon cancer surgical resection and its association with survival: a retrospective observational study. Lancet Oncology. 2008;9(9):857-65. 33. Guillonneau B, Gupta R, El Fettouh H, Cathelineau X, Baumert H, Vallancien G. Laparoscopic management of rectal injury during laparoscopic radical prostatectomy. The Journal of Urology. 2003;169(5):1694-6. 34. Permpongkosol S, Link RE, Su L-M, Romero FR, Bagga HS, Pavlovich CP, et al. Complications of 2,775 urological laparoscopic procedures: 1993 to 2005. The Journal of Urology. 2007;177(2):580-5. 35. Kumakiri J, Kikuchi I, Kitade M, Kuroda K, Matsuoka S, Tokita S, et al. Incidence of complications during gynecologic laparoscopic surgery in patients after previous laparotomy. Journal of Minimally Invasive Gynecology. 2010;17(4):480-6. 36. Navez B, Tassetti V, Scohy J, Mutter D, Guiot P, Evrard S, et al. Laparoscopic management of acute peritonitis. British Journal of Surgery. 1998;85(1):32-6. 37. Chosidow D, Johanet H, Montariol T, Kielt R, Manceau C, Marmuse J, et al. Laparoscopy for acute small-bowel obstruction secondary to adhesions. Journal of Laparoendoscopic & Advanced Surgical Techniques. 2000;10(3):155-9. 38. Sato Y, Ido K, Kumagai M, Isoda N, Hozumi M, Nagamine N, et al. Laparoscopic adhesiolysis for recurrent small bowel obstruction: Long-term follow-up. Gastrointestinal Endoscopy. 2001;54(4):476-9. 39. Bonrath EM, Zevin B, Dedy NJ, Grantcharov TP. Error rating tool to identify and analyse technical errors and events in laparoscopic surgery. British Journal of Surgery. 2013;100(8):1080-8. 40. Westebring-van der Putten EC, Van den Dobbelsteen J, Goossens RHM, Jakimowicz JJ, Dankelman J. Force feedback requirements for efficient laparoscopic grasp control. Ergonomics. 2009;52(9):1055–66. 41. Berguer R. Surgical technology and the ergonomics of laparoscopic instruments. Surgical Endoscopy. 1998;12(5):458-62. 42. Berguer R, Gerber S, Kilpatrick G, Beckley D. An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparoscopic grasper. Surgical Endoscopy. 1998;12(6):805-8. 43. Matern U, Waller P. Instruments for minimally invasive surgery. Surgical Endoscopy. 1999;13(2):174-82. 44. Culmer P, Barrie J, Hewson R, Levesley M, Mon‐Williams M, Jayne D, et al. Reviewing the technological challenges associated with the development of a laparoscopic palpation device. The International Journal of Medical Robotics and Computer Assisted Surgery. 2012;8(2):146-59. 45. Russell L. The Design and Development of an Intelligent Atraumatic Laparoscopic Grasper: University of Leeds; 2015. 46. Reyda CJ. Design of a pressure sensing laparoscopic grasper: Massachusetts Institute of Technology; 2011. 47. Heijnsdijk EAM, Dankelman J, Gouma DJ. Effectiveness of grasping and duration of clamping using laparoscopic graspers. Surgical Endoscopy And Other Interventional Techniques. 2002;16(9):1329-31. 48. De Visser H. Grasping safely: Instruments for bowel manipulation investigated. Delft: Delft University; 2003. 49. Heijnsdijk E, Kragten G, Mugge W, Dankelman J, Gouma D. Fenestrations in the jaws of laparoscopic graspers. Minimally Invasive Therapy & Allied Technologies. 2005;14(1):45-8. 50. Bondakar A, Dargahi J, Bhat R. Investigations on the grasping contact analysis of biological tissues with applications in minimally invasive surgery. American Journal of Applied Sciences. 2007;4(12):1016-23. 51. Marucci D CA, Walsh W and Martin C. Patterns of Failure at the Instrument Tissue Interface. Journal of Surgical Research. 2000;93:16-20. 52. Marucci DD, Cartmill JA, Martin CJ, Walsh WR. A compliant tip reduces the peak pressure of laparoscopic graspers. ANZ Journal of Surgery. 2002;72(7):476-8. 53. Shakeshaft A, Cartmill J, Walsh W, Martin C. A curved edge moderates high pressure generated by a laparoscopic grasper. Surgical Endoscopy. 2001(15):1232-4. 54. Brown A, Brown S, McLean D, Wang Z, Cuschieri A. Impact of fenestrations and surface profiling on the holding of tissue by parallel occlusion laparoscopic graspers. Surgical Endoscopy. 2014;28(4):1277-83. 55. Goyzueta A, Nelson C, Woodin B, Gu L. Experimental Analysis of Jaw-Tissue Interaction Forces Using a Compliant Surgical Grasper. Journal of Medical Devices. 2013;7(2):020917. 56. Susmitha WK, Mathew G, Devasahayam SR, Perakath B, Velusamy SK. Factors influencing forces during laparoscopic pinching: Towards the design of virtual simulator. International Journal of Surgery. 2015;18:211-5. 57. Richards C, Rosen J, Hannaford B, Pellegrini C, Sinanan M. Skills evaluation in minimally invasive surgery using force/torque signatures. Surgical Endoscopy. 2000;14(9):791-8. 58. Rosen J, Hannaford B, Richards CG, Sinanan MN. Markov modeling of minimally invasive surgery based on tool/tissue interaction and force/torque signatures for evaluating surgical skills. Biomedical Engineering, IEEE Transactions on. 2001;48(5):579-91. 59. Valdastri P, Tognarelli S, Menciassi A, Dario P. A scalable platform for biomechanical studies of tissue cutting forces. Measurement Science and Technology. 2009;20(4):045801. 60. Brown JD, Rosen J. Computer-Controlled Motorized Endoscopic Grasper for In Vivo Measurement of Soft Tissue. Medicine Meets Virtual Reality 02/10: Digital Upgrades, Applying Moore's Law to Health. 2002;85:71. 61. Gan LS, Zareinia K, Lama S, Maddahi Y, Yang FW, Sutherland GR. Quantification of Forces During a Neurosurgical Procedure: A Pilot Study. World Neurosurgery. 2015;84(2):537-48. 62. Bergin M, Sheedy M, Ross P, Wylie G, Bird P. Measuring the forces of middle ear surgery; evaluating a novel force-detection instrument. Otology & Neurotology. 2014;35(2):e77-e83. 63. Sunshine S, Balicki M, He X, Olds K, Kang JU, Gehlbach P, et al. A force-sensing microsurgical instrument that detects forces below human tactile sensation. Retina (Philadelphia, Pa). 2013;33(1). 64. Berkelman PJ, Whitcomb LL, Taylor RH, Jensen P. A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation. Robotics and Automation, IEEE Transactions on. 2003;19(5):917-21. 65. Marucci D, Shakeshaft A, Cartmill A, Cox M, Adams S, Martin C. Grasper Trauma During Laparoscopic Cholecystectomy. Aust NZ J Surg. 2000(70):578-81. 66. Morris D, Tan HZ, Barbagli F, Chang T, Salisbury K, editors. Haptic feedback enhances force skill learning. WHC; 2007. 67. Panait L, Akkary E, Bell RL, Roberts KE, Dudrick SJ, Duffy AJ. The role of haptic feedback in laparoscopic simulation training. Journal of Surgical Research. 2009;156(2):312-6. 68. Reiley CE, Akinbiyi T, Burschka D, Chang DC, Okamura AM, Yuh DD. Effects of visual force feedback on robot-assisted surgical task performance. The Journal of Thoracic and Cardiovascular Surgery. 2008;135(1):196-202. 69. van der Meijden OAJ, Schijven MP. The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review. Surgical Endoscopy. 2009;23(6):1180-90. 70. Våpenstad C, Hofstad E, Langø T, Mårvik R, Chmarra M. Perceiving haptic feedback in virtual reality simulators. Surgical Endoscopy. 2013;27(7):2391-7. 71. Kattavenos N, Lawrenson B, Frank T, Pridham M, Keatch R, Cuschieri A. Force sensitive tactile sensor for minimal access surgery. Minimally Invasive Therapy & Allied Technologies. 2004;13(1):42-6. 72. Perri MT, Trejos AL, Naish MD, Patel RV, Malthaner RA. Initial evaluation of a tactile/kinesthetic force feedback system for minimally invasive tumor localization. Mechatronics, IEEE/ASME Transactions on. 2010;15(6):925-31. 73. Tholey G, Desai JP, Castellanos AE. Force feedback plays a significant role in minimally invasive surgery: results and analysis. Annals of Surgery. 2005;241(1):102. 74. Wagner CR, Howe RD, Stylopoulos N, editors. The role of force feedback in surgery: analysis of blunt dissection. Haptic Interfaces for Virtual Environment and Teleoperator Systems, International Symposium on; 2002: IEEE Computer Society. 75. Peirs J, Clijnen J, Reynaerts D, Van Brussel H, Herijgers P, Corteville B, et al. A micro optical force sensor for force feedback during minimally invasive robotic surgery. Sensors and Actuators A: Physical. 2004;115(2):447-55. 76. Mirbagheri A, Farahmand F. A triple jaw actuated and sensorized instrument for grasping large organs during minimally invasive robotic surgery. The International Journal of Medical Robotics and Computer Assisted Surgery. 2013;9(1):83-93. 77. Rosen J, Hannaford B, MacFarlane M, Sinanan M. Force controlled and teleoperated endoscopic grasper for minimally invasive surgery-experimental performance evaluation. IEEE Transactions on Biomedical Engineering 1999;46(10):1212-21. 78. Brown JD, Rosen J, Chang L, Sinanan MN, Hannaford B. Quantifying surgeon grasping mechanics in laparoscopy using the Blue Dragon System. Studies in Health Technology and Informatics. 2004;98:34-6. 79. Hanna G, Drew T, Arnold G, Fakhry M, Cuschieri A. Development of force measurement system for clinical use in minimal access surgery. Surgical Endoscopy. 2008;22(2):467-71. 80. Moradi Dalvand M, Shirinzadeh B, Shamdani AH, Smith J, Zhong Y. An actuated force feedback-enabled laparoscopic instrument for robotic-assisted surgery. The International Journal of Medical Robotics and Computer Assisted Surgery. 2013;10(1):11-21. 81. Horeman T, Rodrigues S, Jansen F-W, Dankelman J, Dobbelsteen J. Force measurement platform for training and assessment of laparoscopic skills. Surgical Endoscopy. 2010;24(12):3102-8. 82. Tholey G, Desai JP. A compact and modular laparoscopic grasper with tridirectional force measurement capability. Journal of Medical Devices. 2008;2(3):031001. 83. De S. The Grasper-tissue interface in minimally invasive surgery:stress and acute indication of injury. Washington: The University of Washington, USA; 2008. 84. Heijnsdijk EAM, van der Voort M, de Visser H, Dankelman J, Gouma DJ. Inter- and intraindividual variabilities of perforation forces of human and pig bowel tissue. Surgical Endoscopy. 2003;17(12):1923-6. 85. Famaey N, Verbeken E, Vinckier S, Willaert B, Herijgers P, Sloten JV. In vivo soft tissue damage assessment for applications in surgery. Medical Engineering & Physics. 2010;32(5):437-43. 86. Brown J, Rosen J, Sinanan M, Hannaford B. In Vivo and Postmortem Compressive Properties of Porcine Abdominal Organs. In: Peters REEaTM, editor. Medical Image Computing and Computer-Assisted Intervention - MICCAI 2003. Lecture Notes in Computer Science. 2878: Springer Berlin / Heidelberg; 2003. p. 238-45. 87. Vonck D, Goossens RHM, Eijk DJ, Hingh IHJT, Jakimowicz JJ. Vacuum grasping as a manipulation technique for minimally invasive surgery. Surgical Endoscopy. 2010;24(10):2418-23. 88. Miyasaka E, Okawada M, Utter B, Mustafa-Maria H, Luntz J, Brei D, et al. Application of Distractive Forces to the Small Intestine: Defining Safe Limits. Journal of Surgical Research. 2010;163(2):169-75. 89. Famaey N, Vander Sloten J, Kuhl E. A three-constituent damage model for arterial clamping in computer-assisted surgery. Biomechanics and Modeling in Mechanobiology. 2013;12(1):123-36. 90. Li W, Jia ZG, Wang J, Shi L, Zhou ZR. Friction behavior at minimally invasive grasper/liver tissue interface. Tribology International. 2015;81:190-8. 91. Mehta N, Haluck R, Frecker M, Snyder A. Sequence and task analysis of instrument use in common laparoscopic procedures. Surgical Endoscopy And Other Interventional Techniques. 2002;16(2):280-5. 92. Sjoerdsma W, Meijer D, Jansen A, Den Boer K, Grimbergen C. Comparison of efficiencies of three techniques for colon surgery. Journal of Laparoendoscopic & Advanced Surgical Techniques. 2000;10(1):47-53. 93. O'Hanley H, Rosario M, Chen Y, Maertens A, Walton J, Rosen J. Design and testing of a three fingered flexural laparoscopic grasper. Transactions of the ASME-W-Journal of Medical Devices. 2011;5(2):027508. 94. Rosen JE, Size A, Yang Y, Sharon A, Sauer-Budge A. Artificial hand for minimally invasive surgery: design and testing of initial prototype. Surgical Endoscopy. 2015;29(1):61-7. 95. Frecker MI, Schadler J, Haluck RS, Culkar K, Dziedzic R. Laparoscopic multifunctional instruments: design and testing of initial prototypes. Journal of the Society of Laparoendscopic Surgeons. 2005;9(1):105-12. 96. Low J-H, Delgado-Martinez I, Yeow C-H. Customizable Soft Pneumatic Chamber–Gripper Devices for Delicate Surgical Manipulation. Journal of Medical Devices. 2014;8(4):044504. 97. Roan PR, Wright AS, Lendvay TS, Sinanan MN, Hannaford B. An instrumented minimally invasive surgical tool: design and calibration. Applied Bionics and Biomechanics. 2011;8(2):173-90. 98. Fischer GS, Akinbiyi T, Saha S, Zand J, Talamini M, Marohn M, et al., editors. Ischemia and force sensing surgical instruments for augmenting available surgeon information. The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. BioRob; 2006: IEEE. 99. Trencheva K, Morrissey KP, Wells M, Mancuso CA, Lee SW, Sonoda T, et al. Identifying important predictors for anastomotic leak after colon and rectal resection: prospective study on 616 patients. Annals of Surgery. 2013;257(1):108-13. 100. Lanir Y. A structural theory for the homogeneous biaxial stress-strain relationships in flat collagenous tissues. Journal of Biomechanics. 1979;12(6):423-36. 101. Kim J-S, Sung I-H, Kim Y-T, Kwon E-Y, Kim D-E, Jang YH. Experimental investigation of frictional and viscoelastic properties of intestine for microendoscope application. Tribology Letters. 2006;22(2):143-9. 102. Bellini C, Glass P, Sitti M, Di Martino ES. Biaxial mechanical modeling of the small intestine. Journal of the Mechanical Behavior of Biomedical Materials. 2011;4(8):1727-40. 103. Phipps S, Yang THJ, Habib FK, Reuben RL, McNeill SA. Measurement of tissue mechanical characteristics to distinguish between benign and malignant prostatic disease. Urology. 2005;66(2):447-50. 104. Davies PJ, Carter FJ, Cuschieri A. Mathematical modelling for keyhole surgery simulations: a biomechanical model for spleen tissue. IMA Journal of Applied Mathematics. 2002;67(1):41-67. 105. Fung Y. Elasticity of soft tissues in simple elongation. American Journal of Physiology 1967;213(6):1532-44. 106. Fung YC, Skalak R. Biomechanics: Mechanical Properties of Living Tissues. Journal of Biomechanical Engineering. 1981;103(4):231-98. 107. Fung F, editor. Biomechanics: Mechanical properties of living tissues. 2nd ed. New York: Springer Verlag; 1993. 108. Yoo L, Kim H, Gupta V, Demer JL. Quasilinear Viscoelastic Behavior of Bovine Extraocular Muscle Tissue. Investigative Ophthalmology & Visual Science. 2009;50(8):3721-8. 109. Taylor DC, Dalton JD, Seaber AV, Garrett WE. Viscoelastic properties of muscle-tendon units. The American Journal of Sports Medicine. 1990;18(3):300-9. 110. Roylance D. Engineering Viscoelasticity 2001 [cited 2010 01/12]. Available from: http://web.mit.edu/course/3/3.11/www/modules/visco.pdf. 111. Brown JD. In-Vivo and Postmortem Biomechanics of Abdominal Organs Under Compressive Loads: Experimental Approach in a Laparoscopic Surgery Set-up. Washington: The University of Washington; 2003. 112. Meidav T. Viscoelastic properties of the standard linear solid. Geophysical Prospecting. 1964;12(1):80-99. 113. Humphrey JD. Vascular mechanics, mechanobiology and remodelling. Journal of Mechanics in Medicine and Biology. 2009;9(2):243-57. 114. Rosen J, Brown JD, De S, Sinanan M, Hannaford B. Biomechanical properties of abdominal organs in vivo and postmortem under compression loads. Journal of Biomechanical Engineering. 2008;130(2):021020. 115. Bilston LE. The Effect of Perfusion on Soft Tissue Mechanical Properties: A Computational Model. Computer Methods in Biomechanics and Biomedical Engineering. 2002;5(4):283 - 90. 116. Kerdok AE, Ottensmeyer MP, Howe RD. Effects of perfusion on the viscoelastic characteristics of liver. Journal of Biomechanics. 2006;39(12):2221-31. 117. Carter FJ, Frank TG, Davies PJ, McLean D, Cuschieri A. Measurements and modelling of the compliance of human and porcine organs. Medical Image Analysis. 2001;5(4):231-6. 118. Lu X, Yang J, Zhao JB, Gregersen H, Kassab GS. Shear modulus of porcine coronary artery: contributions of media and adventitia. American Journal of Physiology - Heart and Circulatory Physiology. 2003;285(5):1966-75. 119. Liao D, Fan Y, Zeng Y, Gregersen H. Stress distribution in the layered wall of the rat oesophagus. Medical Engineering & Physics. 2003;25(9):731-8. 120. Zhao J, Liao D, Chen P, Kunwald P, Gregersen H. Stomach stress and strain depend on location, direction and the layered structure. Journal of Biomechanics. 2008;41(16):3441-7. 121. Brown JD, Rosen J, Kim YS, Chang L, Sinanan M, Hannaford B. In vivo and In situ compressive properties of porcine abdominal soft tissues. In: Westwood JD, Hoffman HM, Mogel G, Phillips R, Robb RA, Stredney D, editors. Medicine Meets Virtual Reality 11, Studies in Health Technology and Informatics: IOS Press; 2003. p. 26-32. 122. Emelianov S, Rubin J, Lubinski M, Skovoroda A, O'Donnell M, editors. Elasticity imaging of the liver: is a hemangioma hard or soft? Ultrasonics Symposium Proceedings IEEE; 1998. 123. Yeh W, Li P, Jeng Y, Hsu H, Kuo P, Li M, et al. Elastic modulus measurements of human liver and correlation with pathology. Ultrasound in Medicine & Biology. 2002;28(4):467-74. 124. Huwart L, Peeters F, Sinkus R, Annet L, Salameh N, ter Beek LC, et al. Liver fibrosis: non-invasive assessment with MR elastography. NMR in Biomedicine. 2006;19(2):173-9. 125. Mazza E, Nava A, Hahnloser D, Jochum W, Bajka M. The mechanical response of human liver and its relation to histology: An in vivo study. Medical Image Analysis. 2007;11(6):663-72. 126. Nava A, Mazza E, Furrer M, Villiger P, Reinhart WH. In vivo mechanical characterization of human liver. Medical Image Analysis. 2008;12(2):203-16. 127. Varghese T, Zagzebski JA, Lee FT. Elastographic imaging of thermal lesions in the liver in vivo following radiofrequency ablation: preliminary results. Ultrasound in Medicine & Biology. 2002;28(11-12):1467-73. 128. Garra BS. Imaging and Estimation of Tissue Elasticity by Ultrasound. Ultrasound Quarterly. 2007;23(4):255-68 129. Carniel EL, Gramigna V, Fontanella CG, Frigo A, Stefanini C, Rubini A, et al. Characterization of the anisotropic mechanical behaviour of colonic tissues: experimental activity and constitutive formulation. Experimental physiology. 2014;99(5):759-71. 130. Christensen MB, Oberg K, Wolchok JC. Tensile properties of the rectal and sigmoid colon: a comparative analysis of human and porcine tissue. SpringerPlus. 2015;4(1):1-10. 131. Hasson H. A modified instrument and method for laparoscopy. American Journal of Obstetrics and Gynecology. 1971;110(6):886-7. 132. Ellis H. Anatomy of the small intestine (jejunum and ileum). Surgery - Oxford International Edition.29(8):355-7. 133. Mahadevan V. Anatomy of the small intestine. Surgery (Oxford). 2014;32(8):391-5. 134. Ellis H. Anatomy of the caecum, appendix and colon. Surgery (Oxford). 2011;29(1):1-4. 135. Turner JR. Intestinal mucosal barrier function in health and disease. Nat Rev Immunol. 2009;9(11):799-809. 136. Haber HP, Stern M. Intestinal ultrasonography in children and young adults: bowel wall thickness is age dependent. Journal of ultrasound in medicine. 2000;19(5):315-21. 137. Lamb. Detailed structure of the bowel wall 2016 [cited 2016 06/09/2016]. Available from: http://www.123rf.com/photo_14192057_drawing-to-show-the-detailed-structure-of-the-bowel-wall-showing-the-arteries-veins-nerves-muscle-la.html. 138. Surgical innovations product range 2012 [cited 2015 01/07/2015]. Available from: http://www.surginno.com/logic-range#products. 139. Swindle M, Makin A, Herron A, Clubb F, Frazier K. Swine as models in biomedical research and toxicology testing. Veterinary Pathology Online. 2012;49(2):344-56. 140. University of Leeds Healthcare Waste Disposal Protocol 2015 [cited 2015]. Available from: http://www.leeds.ac.uk/safety/healthcare/index.htm. 141. Higa M, Luo Y, Okuyama T, Takagi T, Shiraishi Y, Yambe T. Passive mechanical properties of large intestine under in vivo and in vitro compression. Medical Engineering & Physics. 2007;29(8):840-4. 142. Egorov VI, Schastlivtsev IV, Prut EV, Baranov AO, Turusov RA. Mechanical properties of the human gastrointestinal tract. Journal of Biomechanics. 2002;35(10):1417-25. 143. Lawrence I, Lin K. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989:255-68. 144. Barnhart HX, Haber M, Song J. Overall concordance correlation coefficient for evaluating agreement among multiple observers. Biometrics. 2002;58(4):1020-7. 145. Van Der Krabben A, Dijkstra F, Nieuwenhuijzen M, Reijnen M, Schaapveld M, Van Goor H. Morbidity and mortality of inadvertent enterotomy during adhesiotomy. British Journal of surgery. 2000;87(4):467-71. 146. Abdelrahman MA, Marston G, Hull MA, Markham AF, Jones PF, Evans JA, et al. High-frequency ultrasound for in vivo measurement of colon wall thickness in mice. Ultrasound in Medicine & Biology. 2012;38(3):432-42. 147. Barrie J, Jayne DG, Neville A, Hunter L, Hood AJ, Culmer PR. Real-Time Measurement of the Tool-Tissue Interaction in Minimally Invasive Abdominal Surgery The First Step to Developing the Next Generation of Smart Laparoscopic Instruments. Surgical Innovation. 2016 Oct;23(5):463-8. 148. Frank T, Willetts GJ, Carter F, Cuschieri A. Clamping the Small Intestine During Surgery: Predicted and Measured Sealing Forces. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 1995;209(2):111-5. 149. Wullstein C, Gross E. Laparoscopic compared with conventional treatment of acute adhesive small bowel obstruction. British Journal of Surgery. 2003;90(9):1147-51. 150. Suh SW, Park JM, Lee SE, Choi YS. Accidental gallbladder perforation during laparoscopic cholecystectomy: does it have an effect on the clinical outcomes? Journal of Laparoendoscopic & Advanced Surgical Techniques. 2012;22(1):40-5. 151. Demirbas BT, Gulluoglu BM, Aktan AO. Retained Abdominal Gallstones After Laparoscopic Cholecystectomy: A Systematic Review. Surgical Laparoscopy, Endoscopy & Percutaneous Techniques. 2015;25(2):97-9. 152. De S, Rosen J, Dagan A, Hannaford B, Swanson P, Sinanan M. Assessment of Tissue Damage due to Mechanical Stresses. The International Journal of Robotics Research. 2007;26(11-12):1159-71. 153. Venkatasubramanian RT, Grassl ED, Barocas VH, Lafontaine D, Bischof JC. Effects of freezing and cryopreservation on the mechanical properties of arteries. Annals of Biomedical Engineering. 2006;34. 154. Frøkjær JB, Andersen SD, Drewes AM, Gregersen H. Ultrasound-determined geometric and biomechanical properties of the human duodenum. Digestive Diseases and Sciences. 2006;51(9):1662-9. 155. Gao C, Gregersen H. Biomechanical and morphological properties in rat large intestine. Journal of Biomechanics. 2000;33(9):1089-97. 156. Abboudi H, Ahmed K, Royle J, Khan MS, Dasgupta P, N'Dow J. Ureteric injury: a challenging condition to diagnose and manage. Nature Reviews Urology. 2013;10(2):108-15. 157. Briggs J, Wing L, Macdonald A, Tapping C. Suspected iatrogenic ureteric injury: An approach to diagnostic imaging. Clinical radiology. 2014;69(11):454-61. 158. Whiteway J, Morson B. Elastosis in diverticular disease of the sigmoid colon. Gut. 1985;26(3):258-66. 159. Demore CE. Design of ultrasound transducer arrays for medical imaging2007. 160. Lockwood G, Turnball D, Christopher D, Foster F. Beyond 30 MHz [applications of high-frequency ultrasound imaging]. IEEE Engineering in Medicine and Biology Magazine. 1996;15(6):60-71. 161. Adhi M, Duker JS. Optical coherence tomography–current and future applications. Current Opinion in Ophthalmology. 2013;24(3):213. 162. Vakoc BJ, Fukumura D, Jain RK, Bouma BE. Cancer imaging by optical coherence tomography: preclinical progress and clinical potential. Nature Reviews Cancer. 2012;12(5):363-8. 163. Jafari MD, Lee KH, Halabi WJ, Mills SD, Carmichael JC, Stamos MJ, et al. The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery. Surgical Endoscopy. 2013;27(8):3003-8. 164. Taylor GW, Neville A, Jayne DG, Roshan R, Liskiewicz T, Morina A, et al. Wet adhesion for a miniature mobile intra-abdominal device based on biomimetic principles. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science. 2010;224(7):1473-85."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.703364"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/16210/1/Corrected%20thesis_final.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Mechanically induced (or iatrogenic) bowel injury from the use of laparoscopic instruments can result in devastating effects on patient outcomes both during and after surgery. The aim of this work was to investigate exactly how colonic tissue behaves both mechanically and structurally when it is subjected to a mechanical load. Analysis of force application in laparoscopic surgery is critical to understanding the nature of the instrument-tissue interaction. The development of a novel method of both histological analysis and mechanical analysis (by which the tool-tissue interaction can be characterised) has evolved through this thesis. Mechanical and histological analysis was undertaken to quantify the instrument-tissue interaction in laparoscopic surgery. This was done in both ex vivo and in vivo experiments, using an indentation method and laparoscopic instrument respectively, in porcine tissue. Mechanical stress was applied to the colon by indentation applied using the Modular Universal Surface Tester (MUST) (FalexTM Tribology USA) in ex vivo experiments to mechanically characterise the response of tissue to mechanical loading. Histological analysis was performed to examine the architecture of the tissue after loading. In vivo analysis of colon grasping was then performed to characterise grasper damage both mechanically and histologically. A mechanical measure of energy input into the tissue has been linked to consistent histological damage, above a 50 N grasping force and a loading input of 300 N.s This work has successfully identified specific loading conditions that result in tissue injury and is the first to make a link between the mechanical analyses of tissue manipulation with change to the architecture of the tissue."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Next generation of atraumatic laparoscopic instruments through analysis of the instrument-tissue interface"]}]}],"canonical_facts":{"dc:contributor.advisor":["Neville, Anne","Calmer, Peter R.","Jayne, David G.","Pavitt, Sue"],"dc:contributor.sponsor":["Bowel Diseases Research Fund"],"dc:creator":["Barrie, Jenifer"],"dc:date":["2017-02-03"],"dc:date.issued":["2017-02"],"dc:description.abstract":["Mechanically induced (or iatrogenic) bowel injury from the use of laparoscopic instruments can result in devastating effects on patient outcomes both during and after surgery. The aim of this work was to investigate exactly how colonic tissue behaves both mechanically and structurally when it is subjected to a mechanical load. Analysis of force application in laparoscopic surgery is critical to understanding the nature of the instrument-tissue interaction. The development of a novel method of both histological analysis and mechanical analysis (by which the tool-tissue interaction can be characterised) has evolved through this thesis. Mechanical and histological analysis was undertaken to quantify the instrument-tissue interaction in laparoscopic surgery. This was done in both ex vivo and in vivo experiments, using an indentation method and laparoscopic instrument respectively, in porcine tissue. Mechanical stress was applied to the colon by indentation applied using the Modular Universal Surface Tester (MUST) (FalexTM Tribology USA) in ex vivo experiments to mechanically characterise the response of tissue to mechanical loading. Histological analysis was performed to examine the architecture of the tissue after loading. In vivo analysis of colon grasping was then performed to characterise grasper damage both mechanically and histologically. A mechanical measure of energy input into the tissue has been linked to consistent histological damage, above a 50 N grasping force and a loading input of 300 N.s This work has successfully identified specific loading conditions that result in tissue injury and is the first to make a link between the mechanical analyses of tissue manipulation with change to the architecture of the tissue."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.703364"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/16210/1/Corrected%20thesis_final.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Institute of Engineering Thermofluids, Surfaces & Interfaces (iETSI) (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/16210/"],"dc:relation.references":["1. Burns E, Currie A, Bottle A, Aylin P, Darzi A, Faiz O. Minimal‐access colorectal surgery is associated with fewer adhesion related admissions than open surgery. British Journal of Surgery. 2013;100(1):152-9. 2. Yamada T, Okabayashi K, Hasegawa H, Tsuruta M, Yoo JH, Seishima R, et al. Meta‐analysis of the risk of small bowel obstruction following open or laparoscopic colorectal surgery. British Journal of Surgery. 2016. 3. Aquina CT, Probst CP, Becerra AZ, Iannuzzi JC, Hensley BJ, Noyes K, et al. Missed opportunity: laparoscopic colorectal resection is associated with lower incidence of small bowel obstruction compared to an open approach. Annals of Surgery. 2016;264(1):127-34. 4. Wang C-L, Qu G, Xu H-W. The short-and long-term outcomes of laparoscopic versus open surgery for colorectal cancer: a meta-analysis. International Journal of Colorectal Disease. 2014;29(3):309-20. 5. Smith A, Smith J, Jayne D. Telerobotics: Surgery for the 21st century. Surgery. 2006;24(2):74-8. 6. Lanfranco A, Castellanos A, Desai J, Meyers W. Robotic surgery:A current perspective. Annals of Surgery. 2004;239(1):14-21. 7. Turley RS, Barbas AS, Lidsky ME, Mantyh CR, Migaly J, Scarborough JE. Laparoscopic versus open Hartmann procedure for the emergency treatment of diverticulitis: a propensity-matched analysis. Diseases of the Colon & Rectum. 2013;56(1):72-82. 8. Ballian N, Weisensel N, Rajamanickam V, Foley EF, Heise CP, Harms BA, et al. Comparable postoperative morbidity and mortality after laparoscopic and open emergent restorative colectomy: outcomes from the ACS NSQIP. World J Surg. 2012;36(10):2488-96. 9. Tierris I, Mavrantonis C, Stratoulias C, Panousis G, Mpetsou A, Kalochristianakis N. Laparoscopy for acute small bowel obstruction: indication or contraindication? Surgical Endoscopy. 2011;25(2):531-5. 10. Bertleff MJ, Lange JF. Laparoscopic correction of perforated peptic ulcer: first choice? A review of literature. Surgical Endoscopy. 2010;24(6):1231-9. 11. Gash K, Chambers W, Ghosh A, Dixon A. The role of laparoscopic surgery for the management of acute large bowel obstruction. Colorectal Disease. 2011;13(3):263-6. 12. Royds J, O’Riordan J, Eguare E, O’Riordan D, Neary P. Laparoscopic surgery for complicated diverticular disease: a single‐centre experience. Colorectal Disease. 2012;14(10):1248-54. 13. Vettoretto N, Gazzola L, Giovanetti M. Emergency Laparoscopic Ileocecal Resection for Crohn's Acute Obstruction. JSLS: Journal of the Society of Laparoendoscopic Surgeons. 2013;17(3):499-502. 14. O’Connor DB, Winter DC. The role of laparoscopy in the management of acute small-bowel obstruction: a review of over 2,000 cases. Surgical Endoscopy. 2012;26(1):12-7. 15. Kyung MS, Choi JS, Lee JH, Jung US, Lee KW. Laparoscopic management of complications in gynecologic laparoscopic surgery: a 5-year experience in a single center. Journal of Minimally Invasive Gynecology. 2008;15(6):689-94. 16. Suter M, Zermatten P, Halkic N, Martinet O, Bettschart V. Laparoscopic management of mechanical small bowel obstruction. Surg Endosc. 2000;14(5):478-83. 17. Szomstein S, Menzo EL, Simpfendorfer C, Zundel N, Rosenthal RJ. Laparoscopic lysis of adhesions. World Journal of Surgery. 2006;30(4):535-40. 18. Forbes S, Eskicioglu C, McLeod R, Okrainec A. Meta analysis of randomized controlled trials comparing open and laparoscopic ventral and incisional hernia repair with mesh. British Journal of Surgery. 2009;96(8):851-8. 19. Makino T, Milsom JW, Lee SW. Feasibility and safety of single-incision laparoscopic colectomy: a systematic review. Annals of Surgery. 2012;255(4):667-76. 20. Fung AY, Aly E. Systematic review of single incision laparoscopic colonic surgery. British Journal of Surgery. 2012;99(10):1353-64. 21. Haber G-P, White MA, Autorino R, Escobar PF, Kroh MD, Chalikonda S, et al. Novel robotic da Vinci instruments for laparoendoscopic single-site surgery. Urology. 2010;76(6):1279-82. 22. Kennedy GD, Heise C, Rajamanickam V, Harms B, Foley EF. Laparoscopy decreases postoperative complication rates after abdominal colectomy: results from the national surgical quality improvement program. Annals of Surgery. 2009;249(4):596-601. 23. Barrie J, Jayne DG, Wright J, Murray CJC, Collinson FJ, Pavitt SH. Attaining Surgical Competency and Its Implications in Surgical Clinical Trial Design: A Systematic Review of the Learning Curve in Laparoscopic and Robot-Assisted Laparoscopic Colorectal Cancer Surgery. Annals of Surgical Oncology. 2014;21(3): 829-840. 24. Van der Voort M, Heijnsdijk E, Gouma D. Bowel injury as a complication of laparoscopy. British Journal of Surgery. 2004;91(10):1253-8. 25. Sammour T, Kahokehr A, Srinivasa S, Bissett IP, Hill AG. Laparoscopic colorectal surgery is associated with a higher intraoperative complication rate than open surgery. Annals of Surgery. 2011;253(1):35-43. 26. Tang BB, Hanna GB, Joice PP, Cuschieri AA. Identification and categorization of technical errors by observational clinical human reliability assessment (ochra) during laparoscopic cholecystectomy. Archives of Surgery. 2004;139(11):1215-20. 27. Levy B, De Guara J, Willson P, Soon Y, Kent A, Rockall T. Bladder injuries in emergency/expedited laparoscopic surgery in the absence of previous surgery: a case series. Annals of the Royal College of Surgeons of England. 2012;94(3):e118-20. 28. Tian Y-F, Lin Y-S, Lu C-L, Chia C-C, Huang K-F, Shih T-Y, et al. Major complications of operative gynecologic laparoscopy in southern Taiwan: a follow-up study. Journal of Minimally Invasive Gynecology. 2007;14(3):284-92. 29. Chung BI, Desai MM, Gill IS. Management of intraoperative splenic injury during laparoscopic urological surgery. BJU International. 2011;108(4):572-6. 30. Nagtegaal I, Cornelis J, van der Velde E, van der Worp E, Kapiteijn E, Quirke P, et al. Macroscopic evaluation of rectal cancer resection specimen: clinical significance of the pathologist in quality control. Journal of Clinical Oncology 2002;20(7):1729-34 31. West N, Hohenberger W, Weber K, Perrakis A, Finan P, P. Q. Complete mesocolic excision with central vascular ligation produces an oncologically superior specimen compared with standard surgery for carcinoma of the colon. Journal of Clinical Oncology 2010;28(2):272-8. 32. West N, Morris E, Rotimi O, Cairns A, Finan P, Quirke P. Pathology grading of colon cancer surgical resection and its association with survival: a retrospective observational study. Lancet Oncology. 2008;9(9):857-65. 33. Guillonneau B, Gupta R, El Fettouh H, Cathelineau X, Baumert H, Vallancien G. Laparoscopic management of rectal injury during laparoscopic radical prostatectomy. The Journal of Urology. 2003;169(5):1694-6. 34. Permpongkosol S, Link RE, Su L-M, Romero FR, Bagga HS, Pavlovich CP, et al. Complications of 2,775 urological laparoscopic procedures: 1993 to 2005. The Journal of Urology. 2007;177(2):580-5. 35. Kumakiri J, Kikuchi I, Kitade M, Kuroda K, Matsuoka S, Tokita S, et al. Incidence of complications during gynecologic laparoscopic surgery in patients after previous laparotomy. Journal of Minimally Invasive Gynecology. 2010;17(4):480-6. 36. Navez B, Tassetti V, Scohy J, Mutter D, Guiot P, Evrard S, et al. Laparoscopic management of acute peritonitis. British Journal of Surgery. 1998;85(1):32-6. 37. Chosidow D, Johanet H, Montariol T, Kielt R, Manceau C, Marmuse J, et al. Laparoscopy for acute small-bowel obstruction secondary to adhesions. Journal of Laparoendoscopic & Advanced Surgical Techniques. 2000;10(3):155-9. 38. Sato Y, Ido K, Kumagai M, Isoda N, Hozumi M, Nagamine N, et al. Laparoscopic adhesiolysis for recurrent small bowel obstruction: Long-term follow-up. Gastrointestinal Endoscopy. 2001;54(4):476-9. 39. Bonrath EM, Zevin B, Dedy NJ, Grantcharov TP. Error rating tool to identify and analyse technical errors and events in laparoscopic surgery. British Journal of Surgery. 2013;100(8):1080-8. 40. Westebring-van der Putten EC, Van den Dobbelsteen J, Goossens RHM, Jakimowicz JJ, Dankelman J. Force feedback requirements for efficient laparoscopic grasp control. Ergonomics. 2009;52(9):1055–66. 41. Berguer R. Surgical technology and the ergonomics of laparoscopic instruments. Surgical Endoscopy. 1998;12(5):458-62. 42. Berguer R, Gerber S, Kilpatrick G, Beckley D. An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparoscopic grasper. Surgical Endoscopy. 1998;12(6):805-8. 43. Matern U, Waller P. Instruments for minimally invasive surgery. Surgical Endoscopy. 1999;13(2):174-82. 44. Culmer P, Barrie J, Hewson R, Levesley M, Mon‐Williams M, Jayne D, et al. Reviewing the technological challenges associated with the development of a laparoscopic palpation device. The International Journal of Medical Robotics and Computer Assisted Surgery. 2012;8(2):146-59. 45. Russell L. The Design and Development of an Intelligent Atraumatic Laparoscopic Grasper: University of Leeds; 2015. 46. Reyda CJ. Design of a pressure sensing laparoscopic grasper: Massachusetts Institute of Technology; 2011. 47. Heijnsdijk EAM, Dankelman J, Gouma DJ. Effectiveness of grasping and duration of clamping using laparoscopic graspers. Surgical Endoscopy And Other Interventional Techniques. 2002;16(9):1329-31. 48. De Visser H. Grasping safely: Instruments for bowel manipulation investigated. Delft: Delft University; 2003. 49. Heijnsdijk E, Kragten G, Mugge W, Dankelman J, Gouma D. Fenestrations in the jaws of laparoscopic graspers. Minimally Invasive Therapy & Allied Technologies. 2005;14(1):45-8. 50. Bondakar A, Dargahi J, Bhat R. Investigations on the grasping contact analysis of biological tissues with applications in minimally invasive surgery. American Journal of Applied Sciences. 2007;4(12):1016-23. 51. Marucci D CA, Walsh W and Martin C. Patterns of Failure at the Instrument Tissue Interface. Journal of Surgical Research. 2000;93:16-20. 52. Marucci DD, Cartmill JA, Martin CJ, Walsh WR. A compliant tip reduces the peak pressure of laparoscopic graspers. ANZ Journal of Surgery. 2002;72(7):476-8. 53. Shakeshaft A, Cartmill J, Walsh W, Martin C. A curved edge moderates high pressure generated by a laparoscopic grasper. Surgical Endoscopy. 2001(15):1232-4. 54. Brown A, Brown S, McLean D, Wang Z, Cuschieri A. Impact of fenestrations and surface profiling on the holding of tissue by parallel occlusion laparoscopic graspers. Surgical Endoscopy. 2014;28(4):1277-83. 55. Goyzueta A, Nelson C, Woodin B, Gu L. Experimental Analysis of Jaw-Tissue Interaction Forces Using a Compliant Surgical Grasper. Journal of Medical Devices. 2013;7(2):020917. 56. Susmitha WK, Mathew G, Devasahayam SR, Perakath B, Velusamy SK. Factors influencing forces during laparoscopic pinching: Towards the design of virtual simulator. International Journal of Surgery. 2015;18:211-5. 57. Richards C, Rosen J, Hannaford B, Pellegrini C, Sinanan M. Skills evaluation in minimally invasive surgery using force/torque signatures. Surgical Endoscopy. 2000;14(9):791-8. 58. Rosen J, Hannaford B, Richards CG, Sinanan MN. Markov modeling of minimally invasive surgery based on tool/tissue interaction and force/torque signatures for evaluating surgical skills. Biomedical Engineering, IEEE Transactions on. 2001;48(5):579-91. 59. Valdastri P, Tognarelli S, Menciassi A, Dario P. A scalable platform for biomechanical studies of tissue cutting forces. Measurement Science and Technology. 2009;20(4):045801. 60. Brown JD, Rosen J. Computer-Controlled Motorized Endoscopic Grasper for In Vivo Measurement of Soft Tissue. Medicine Meets Virtual Reality 02/10: Digital Upgrades, Applying Moore's Law to Health. 2002;85:71. 61. Gan LS, Zareinia K, Lama S, Maddahi Y, Yang FW, Sutherland GR. Quantification of Forces During a Neurosurgical Procedure: A Pilot Study. World Neurosurgery. 2015;84(2):537-48. 62. Bergin M, Sheedy M, Ross P, Wylie G, Bird P. Measuring the forces of middle ear surgery; evaluating a novel force-detection instrument. Otology & Neurotology. 2014;35(2):e77-e83. 63. Sunshine S, Balicki M, He X, Olds K, Kang JU, Gehlbach P, et al. A force-sensing microsurgical instrument that detects forces below human tactile sensation. Retina (Philadelphia, Pa). 2013;33(1). 64. Berkelman PJ, Whitcomb LL, Taylor RH, Jensen P. A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation. Robotics and Automation, IEEE Transactions on. 2003;19(5):917-21. 65. Marucci D, Shakeshaft A, Cartmill A, Cox M, Adams S, Martin C. Grasper Trauma During Laparoscopic Cholecystectomy. Aust NZ J Surg. 2000(70):578-81. 66. Morris D, Tan HZ, Barbagli F, Chang T, Salisbury K, editors. Haptic feedback enhances force skill learning. WHC; 2007. 67. Panait L, Akkary E, Bell RL, Roberts KE, Dudrick SJ, Duffy AJ. The role of haptic feedback in laparoscopic simulation training. Journal of Surgical Research. 2009;156(2):312-6. 68. Reiley CE, Akinbiyi T, Burschka D, Chang DC, Okamura AM, Yuh DD. Effects of visual force feedback on robot-assisted surgical task performance. The Journal of Thoracic and Cardiovascular Surgery. 2008;135(1):196-202. 69. van der Meijden OAJ, Schijven MP. The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review. Surgical Endoscopy. 2009;23(6):1180-90. 70. Våpenstad C, Hofstad E, Langø T, Mårvik R, Chmarra M. Perceiving haptic feedback in virtual reality simulators. Surgical Endoscopy. 2013;27(7):2391-7. 71. Kattavenos N, Lawrenson B, Frank T, Pridham M, Keatch R, Cuschieri A. Force sensitive tactile sensor for minimal access surgery. Minimally Invasive Therapy & Allied Technologies. 2004;13(1):42-6. 72. Perri MT, Trejos AL, Naish MD, Patel RV, Malthaner RA. Initial evaluation of a tactile/kinesthetic force feedback system for minimally invasive tumor localization. Mechatronics, IEEE/ASME Transactions on. 2010;15(6):925-31. 73. Tholey G, Desai JP, Castellanos AE. Force feedback plays a significant role in minimally invasive surgery: results and analysis. Annals of Surgery. 2005;241(1):102. 74. Wagner CR, Howe RD, Stylopoulos N, editors. The role of force feedback in surgery: analysis of blunt dissection. Haptic Interfaces for Virtual Environment and Teleoperator Systems, International Symposium on; 2002: IEEE Computer Society. 75. Peirs J, Clijnen J, Reynaerts D, Van Brussel H, Herijgers P, Corteville B, et al. A micro optical force sensor for force feedback during minimally invasive robotic surgery. Sensors and Actuators A: Physical. 2004;115(2):447-55. 76. Mirbagheri A, Farahmand F. A triple jaw actuated and sensorized instrument for grasping large organs during minimally invasive robotic surgery. The International Journal of Medical Robotics and Computer Assisted Surgery. 2013;9(1):83-93. 77. Rosen J, Hannaford B, MacFarlane M, Sinanan M. Force controlled and teleoperated endoscopic grasper for minimally invasive surgery-experimental performance evaluation. IEEE Transactions on Biomedical Engineering 1999;46(10):1212-21. 78. Brown JD, Rosen J, Chang L, Sinanan MN, Hannaford B. Quantifying surgeon grasping mechanics in laparoscopy using the Blue Dragon System. Studies in Health Technology and Informatics. 2004;98:34-6. 79. Hanna G, Drew T, Arnold G, Fakhry M, Cuschieri A. Development of force measurement system for clinical use in minimal access surgery. Surgical Endoscopy. 2008;22(2):467-71. 80. Moradi Dalvand M, Shirinzadeh B, Shamdani AH, Smith J, Zhong Y. An actuated force feedback-enabled laparoscopic instrument for robotic-assisted surgery. The International Journal of Medical Robotics and Computer Assisted Surgery. 2013;10(1):11-21. 81. Horeman T, Rodrigues S, Jansen F-W, Dankelman J, Dobbelsteen J. Force measurement platform for training and assessment of laparoscopic skills. Surgical Endoscopy. 2010;24(12):3102-8. 82. Tholey G, Desai JP. A compact and modular laparoscopic grasper with tridirectional force measurement capability. Journal of Medical Devices. 2008;2(3):031001. 83. De S. The Grasper-tissue interface in minimally invasive surgery:stress and acute indication of injury. Washington: The University of Washington, USA; 2008. 84. Heijnsdijk EAM, van der Voort M, de Visser H, Dankelman J, Gouma DJ. Inter- and intraindividual variabilities of perforation forces of human and pig bowel tissue. Surgical Endoscopy. 2003;17(12):1923-6. 85. Famaey N, Verbeken E, Vinckier S, Willaert B, Herijgers P, Sloten JV. In vivo soft tissue damage assessment for applications in surgery. Medical Engineering & Physics. 2010;32(5):437-43. 86. Brown J, Rosen J, Sinanan M, Hannaford B. In Vivo and Postmortem Compressive Properties of Porcine Abdominal Organs. In: Peters REEaTM, editor. Medical Image Computing and Computer-Assisted Intervention - MICCAI 2003. Lecture Notes in Computer Science. 2878: Springer Berlin / Heidelberg; 2003. p. 238-45. 87. Vonck D, Goossens RHM, Eijk DJ, Hingh IHJT, Jakimowicz JJ. Vacuum grasping as a manipulation technique for minimally invasive surgery. Surgical Endoscopy. 2010;24(10):2418-23. 88. Miyasaka E, Okawada M, Utter B, Mustafa-Maria H, Luntz J, Brei D, et al. Application of Distractive Forces to the Small Intestine: Defining Safe Limits. Journal of Surgical Research. 2010;163(2):169-75. 89. Famaey N, Vander Sloten J, Kuhl E. A three-constituent damage model for arterial clamping in computer-assisted surgery. Biomechanics and Modeling in Mechanobiology. 2013;12(1):123-36. 90. Li W, Jia ZG, Wang J, Shi L, Zhou ZR. Friction behavior at minimally invasive grasper/liver tissue interface. Tribology International. 2015;81:190-8. 91. Mehta N, Haluck R, Frecker M, Snyder A. Sequence and task analysis of instrument use in common laparoscopic procedures. Surgical Endoscopy And Other Interventional Techniques. 2002;16(2):280-5. 92. Sjoerdsma W, Meijer D, Jansen A, Den Boer K, Grimbergen C. Comparison of efficiencies of three techniques for colon surgery. Journal of Laparoendoscopic & Advanced Surgical Techniques. 2000;10(1):47-53. 93. O'Hanley H, Rosario M, Chen Y, Maertens A, Walton J, Rosen J. Design and testing of a three fingered flexural laparoscopic grasper. Transactions of the ASME-W-Journal of Medical Devices. 2011;5(2):027508. 94. Rosen JE, Size A, Yang Y, Sharon A, Sauer-Budge A. Artificial hand for minimally invasive surgery: design and testing of initial prototype. Surgical Endoscopy. 2015;29(1):61-7. 95. Frecker MI, Schadler J, Haluck RS, Culkar K, Dziedzic R. Laparoscopic multifunctional instruments: design and testing of initial prototypes. Journal of the Society of Laparoendscopic Surgeons. 2005;9(1):105-12. 96. Low J-H, Delgado-Martinez I, Yeow C-H. Customizable Soft Pneumatic Chamber–Gripper Devices for Delicate Surgical Manipulation. Journal of Medical Devices. 2014;8(4):044504. 97. Roan PR, Wright AS, Lendvay TS, Sinanan MN, Hannaford B. An instrumented minimally invasive surgical tool: design and calibration. Applied Bionics and Biomechanics. 2011;8(2):173-90. 98. Fischer GS, Akinbiyi T, Saha S, Zand J, Talamini M, Marohn M, et al., editors. Ischemia and force sensing surgical instruments for augmenting available surgeon information. The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. BioRob; 2006: IEEE. 99. Trencheva K, Morrissey KP, Wells M, Mancuso CA, Lee SW, Sonoda T, et al. Identifying important predictors for anastomotic leak after colon and rectal resection: prospective study on 616 patients. Annals of Surgery. 2013;257(1):108-13. 100. Lanir Y. A structural theory for the homogeneous biaxial stress-strain relationships in flat collagenous tissues. Journal of Biomechanics. 1979;12(6):423-36. 101. Kim J-S, Sung I-H, Kim Y-T, Kwon E-Y, Kim D-E, Jang YH. Experimental investigation of frictional and viscoelastic properties of intestine for microendoscope application. Tribology Letters. 2006;22(2):143-9. 102. Bellini C, Glass P, Sitti M, Di Martino ES. Biaxial mechanical modeling of the small intestine. Journal of the Mechanical Behavior of Biomedical Materials. 2011;4(8):1727-40. 103. Phipps S, Yang THJ, Habib FK, Reuben RL, McNeill SA. Measurement of tissue mechanical characteristics to distinguish between benign and malignant prostatic disease. Urology. 2005;66(2):447-50. 104. Davies PJ, Carter FJ, Cuschieri A. Mathematical modelling for keyhole surgery simulations: a biomechanical model for spleen tissue. IMA Journal of Applied Mathematics. 2002;67(1):41-67. 105. Fung Y. Elasticity of soft tissues in simple elongation. American Journal of Physiology 1967;213(6):1532-44. 106. Fung YC, Skalak R. Biomechanics: Mechanical Properties of Living Tissues. Journal of Biomechanical Engineering. 1981;103(4):231-98. 107. Fung F, editor. Biomechanics: Mechanical properties of living tissues. 2nd ed. New York: Springer Verlag; 1993. 108. Yoo L, Kim H, Gupta V, Demer JL. Quasilinear Viscoelastic Behavior of Bovine Extraocular Muscle Tissue. Investigative Ophthalmology & Visual Science. 2009;50(8):3721-8. 109. Taylor DC, Dalton JD, Seaber AV, Garrett WE. Viscoelastic properties of muscle-tendon units. The American Journal of Sports Medicine. 1990;18(3):300-9. 110. Roylance D. Engineering Viscoelasticity 2001 [cited 2010 01/12]. Available from: http://web.mit.edu/course/3/3.11/www/modules/visco.pdf. 111. Brown JD. In-Vivo and Postmortem Biomechanics of Abdominal Organs Under Compressive Loads: Experimental Approach in a Laparoscopic Surgery Set-up. Washington: The University of Washington; 2003. 112. Meidav T. Viscoelastic properties of the standard linear solid. Geophysical Prospecting. 1964;12(1):80-99. 113. Humphrey JD. Vascular mechanics, mechanobiology and remodelling. Journal of Mechanics in Medicine and Biology. 2009;9(2):243-57. 114. Rosen J, Brown JD, De S, Sinanan M, Hannaford B. Biomechanical properties of abdominal organs in vivo and postmortem under compression loads. Journal of Biomechanical Engineering. 2008;130(2):021020. 115. Bilston LE. The Effect of Perfusion on Soft Tissue Mechanical Properties: A Computational Model. Computer Methods in Biomechanics and Biomedical Engineering. 2002;5(4):283 - 90. 116. Kerdok AE, Ottensmeyer MP, Howe RD. Effects of perfusion on the viscoelastic characteristics of liver. Journal of Biomechanics. 2006;39(12):2221-31. 117. Carter FJ, Frank TG, Davies PJ, McLean D, Cuschieri A. Measurements and modelling of the compliance of human and porcine organs. Medical Image Analysis. 2001;5(4):231-6. 118. Lu X, Yang J, Zhao JB, Gregersen H, Kassab GS. Shear modulus of porcine coronary artery: contributions of media and adventitia. American Journal of Physiology - Heart and Circulatory Physiology. 2003;285(5):1966-75. 119. Liao D, Fan Y, Zeng Y, Gregersen H. Stress distribution in the layered wall of the rat oesophagus. Medical Engineering & Physics. 2003;25(9):731-8. 120. Zhao J, Liao D, Chen P, Kunwald P, Gregersen H. Stomach stress and strain depend on location, direction and the layered structure. Journal of Biomechanics. 2008;41(16):3441-7. 121. Brown JD, Rosen J, Kim YS, Chang L, Sinanan M, Hannaford B. In vivo and In situ compressive properties of porcine abdominal soft tissues. In: Westwood JD, Hoffman HM, Mogel G, Phillips R, Robb RA, Stredney D, editors. Medicine Meets Virtual Reality 11, Studies in Health Technology and Informatics: IOS Press; 2003. p. 26-32. 122. Emelianov S, Rubin J, Lubinski M, Skovoroda A, O'Donnell M, editors. Elasticity imaging of the liver: is a hemangioma hard or soft? Ultrasonics Symposium Proceedings IEEE; 1998. 123. Yeh W, Li P, Jeng Y, Hsu H, Kuo P, Li M, et al. Elastic modulus measurements of human liver and correlation with pathology. Ultrasound in Medicine & Biology. 2002;28(4):467-74. 124. Huwart L, Peeters F, Sinkus R, Annet L, Salameh N, ter Beek LC, et al. Liver fibrosis: non-invasive assessment with MR elastography. NMR in Biomedicine. 2006;19(2):173-9. 125. Mazza E, Nava A, Hahnloser D, Jochum W, Bajka M. The mechanical response of human liver and its relation to histology: An in vivo study. Medical Image Analysis. 2007;11(6):663-72. 126. Nava A, Mazza E, Furrer M, Villiger P, Reinhart WH. In vivo mechanical characterization of human liver. Medical Image Analysis. 2008;12(2):203-16. 127. Varghese T, Zagzebski JA, Lee FT. Elastographic imaging of thermal lesions in the liver in vivo following radiofrequency ablation: preliminary results. Ultrasound in Medicine & Biology. 2002;28(11-12):1467-73. 128. Garra BS. Imaging and Estimation of Tissue Elasticity by Ultrasound. Ultrasound Quarterly. 2007;23(4):255-68 129. Carniel EL, Gramigna V, Fontanella CG, Frigo A, Stefanini C, Rubini A, et al. Characterization of the anisotropic mechanical behaviour of colonic tissues: experimental activity and constitutive formulation. Experimental physiology. 2014;99(5):759-71. 130. Christensen MB, Oberg K, Wolchok JC. Tensile properties of the rectal and sigmoid colon: a comparative analysis of human and porcine tissue. SpringerPlus. 2015;4(1):1-10. 131. Hasson H. A modified instrument and method for laparoscopy. American Journal of Obstetrics and Gynecology. 1971;110(6):886-7. 132. Ellis H. Anatomy of the small intestine (jejunum and ileum). Surgery - Oxford International Edition.29(8):355-7. 133. Mahadevan V. Anatomy of the small intestine. Surgery (Oxford). 2014;32(8):391-5. 134. Ellis H. Anatomy of the caecum, appendix and colon. Surgery (Oxford). 2011;29(1):1-4. 135. Turner JR. Intestinal mucosal barrier function in health and disease. Nat Rev Immunol. 2009;9(11):799-809. 136. Haber HP, Stern M. Intestinal ultrasonography in children and young adults: bowel wall thickness is age dependent. Journal of ultrasound in medicine. 2000;19(5):315-21. 137. Lamb. Detailed structure of the bowel wall 2016 [cited 2016 06/09/2016]. Available from: http://www.123rf.com/photo_14192057_drawing-to-show-the-detailed-structure-of-the-bowel-wall-showing-the-arteries-veins-nerves-muscle-la.html. 138. Surgical innovations product range 2012 [cited 2015 01/07/2015]. Available from: http://www.surginno.com/logic-range#products. 139. Swindle M, Makin A, Herron A, Clubb F, Frazier K. Swine as models in biomedical research and toxicology testing. Veterinary Pathology Online. 2012;49(2):344-56. 140. University of Leeds Healthcare Waste Disposal Protocol 2015 [cited 2015]. Available from: http://www.leeds.ac.uk/safety/healthcare/index.htm. 141. Higa M, Luo Y, Okuyama T, Takagi T, Shiraishi Y, Yambe T. Passive mechanical properties of large intestine under in vivo and in vitro compression. Medical Engineering & Physics. 2007;29(8):840-4. 142. Egorov VI, Schastlivtsev IV, Prut EV, Baranov AO, Turusov RA. Mechanical properties of the human gastrointestinal tract. Journal of Biomechanics. 2002;35(10):1417-25. 143. Lawrence I, Lin K. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989:255-68. 144. Barnhart HX, Haber M, Song J. Overall concordance correlation coefficient for evaluating agreement among multiple observers. Biometrics. 2002;58(4):1020-7. 145. Van Der Krabben A, Dijkstra F, Nieuwenhuijzen M, Reijnen M, Schaapveld M, Van Goor H. Morbidity and mortality of inadvertent enterotomy during adhesiotomy. British Journal of surgery. 2000;87(4):467-71. 146. Abdelrahman MA, Marston G, Hull MA, Markham AF, Jones PF, Evans JA, et al. High-frequency ultrasound for in vivo measurement of colon wall thickness in mice. Ultrasound in Medicine & Biology. 2012;38(3):432-42. 147. Barrie J, Jayne DG, Neville A, Hunter L, Hood AJ, Culmer PR. Real-Time Measurement of the Tool-Tissue Interaction in Minimally Invasive Abdominal Surgery The First Step to Developing the Next Generation of Smart Laparoscopic Instruments. Surgical Innovation. 2016 Oct;23(5):463-8. 148. Frank T, Willetts GJ, Carter F, Cuschieri A. Clamping the Small Intestine During Surgery: Predicted and Measured Sealing Forces. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 1995;209(2):111-5. 149. Wullstein C, Gross E. Laparoscopic compared with conventional treatment of acute adhesive small bowel obstruction. British Journal of Surgery. 2003;90(9):1147-51. 150. Suh SW, Park JM, Lee SE, Choi YS. Accidental gallbladder perforation during laparoscopic cholecystectomy: does it have an effect on the clinical outcomes? Journal of Laparoendoscopic & Advanced Surgical Techniques. 2012;22(1):40-5. 151. Demirbas BT, Gulluoglu BM, Aktan AO. Retained Abdominal Gallstones After Laparoscopic Cholecystectomy: A Systematic Review. Surgical Laparoscopy, Endoscopy & Percutaneous Techniques. 2015;25(2):97-9. 152. De S, Rosen J, Dagan A, Hannaford B, Swanson P, Sinanan M. Assessment of Tissue Damage due to Mechanical Stresses. The International Journal of Robotics Research. 2007;26(11-12):1159-71. 153. Venkatasubramanian RT, Grassl ED, Barocas VH, Lafontaine D, Bischof JC. Effects of freezing and cryopreservation on the mechanical properties of arteries. Annals of Biomedical Engineering. 2006;34. 154. Frøkjær JB, Andersen SD, Drewes AM, Gregersen H. Ultrasound-determined geometric and biomechanical properties of the human duodenum. Digestive Diseases and Sciences. 2006;51(9):1662-9. 155. Gao C, Gregersen H. Biomechanical and morphological properties in rat large intestine. Journal of Biomechanics. 2000;33(9):1089-97. 156. Abboudi H, Ahmed K, Royle J, Khan MS, Dasgupta P, N'Dow J. Ureteric injury: a challenging condition to diagnose and manage. Nature Reviews Urology. 2013;10(2):108-15. 157. Briggs J, Wing L, Macdonald A, Tapping C. Suspected iatrogenic ureteric injury: An approach to diagnostic imaging. Clinical radiology. 2014;69(11):454-61. 158. Whiteway J, Morson B. Elastosis in diverticular disease of the sigmoid colon. Gut. 1985;26(3):258-66. 159. Demore CE. Design of ultrasound transducer arrays for medical imaging2007. 160. Lockwood G, Turnball D, Christopher D, Foster F. Beyond 30 MHz [applications of high-frequency ultrasound imaging]. IEEE Engineering in Medicine and Biology Magazine. 1996;15(6):60-71. 161. Adhi M, Duker JS. Optical coherence tomography–current and future applications. Current Opinion in Ophthalmology. 2013;24(3):213. 162. Vakoc BJ, Fukumura D, Jain RK, Bouma BE. Cancer imaging by optical coherence tomography: preclinical progress and clinical potential. Nature Reviews Cancer. 2012;12(5):363-8. 163. Jafari MD, Lee KH, Halabi WJ, Mills SD, Carmichael JC, Stamos MJ, et al. The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery. Surgical Endoscopy. 2013;27(8):3003-8. 164. Taylor GW, Neville A, Jayne DG, Roshan R, Liskiewicz T, Morina A, et al. Wet adhesion for a miniature mobile intra-abdominal device based on biomimetic principles. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science. 2010;224(7):1473-85."],"dcterms:accessrights":["public"],"dc:title":["Next generation of atraumatic laparoscopic instruments through analysis of the instrument-tissue interface"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:19:32Z"}