{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:16399"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:16399","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"The Design and Development of a Mobile Colonoscopy Robot","abstract":"The conventional colonoscopy is a common procedure used to access the colon. Despite it being considered the Gold Standard procedure for colorectal cancer diagnosis and treatment, it has a number of major drawbacks, including high patient discomfort, infrequent but serious complications and high skill required to perform the procedure. There are a number of potential alternatives to the conventional colonoscopy, from augmenting the colonoscope to using Computed Tomography Colonography (CTC) - a completely non-invasive method. However, a truly effective, all-round alternative has yet to be found. This thesis explores the design and development of a novel solution: a fully mobile colonoscopy robot called “RollerBall”. Unlike current passive diagnostic capsules, such as PillCam, this device uses wheels at the end of adjustable arms to provide locomotion through the colon, while providing a stable platform for the use of diagnostic and therapeutic tools. The work begins by reviewing relevant literature to better understand the problem and potential solutions. RollerBall is then introduced and its design described in detail. A robust prototype was then successfully fabricated using a 3D printing technique and its performance assessed in a series of benchtop experiments. These showed that the mechanisms functioned as intended and encouraged the further development of the concept. Next, the fundamental requirement of gaining traction on the colon was shown to be possible using hexagonal shaped, macro-scale tread patterns. A friction coefficient ranging between 0.29 and 0.55 was achieved with little trauma to the tissue substrate. The electronics hardware and control were then developed and evaluated in a series of tests in silicone tubes. An open-loop strategy was first used to establish the control algorithm to map the user inputs to motor outputs (wheel speeds). These tests showed the efficacy of the locomotion technique and the control algorithm used, but they highlighted the need for autonomy. To address this, feedback was included to automate the adjusting of the arm angle and amount of force applied by the device; a forward facing camera was also used to automate the orientation control by tracking a user-defined target. Force and orientation control were then combined to show that semi-autonomous control was possible and as a result, it was concluded that clinical use may be feasible in future developments.","abstract_html":"The conventional colonoscopy is a common procedure used to access the colon. Despite it being considered the Gold Standard procedure for colorectal cancer diagnosis and treatment, it has a number of major drawbacks, including high patient discomfort, infrequent but serious complications and high skill required to perform the procedure. There are a number of potential alternatives to the conventional colonoscopy, from augmenting the colonoscope to using Computed Tomography Colonography (CTC) - a completely non-invasive method. However, a truly effective, all-round alternative has yet to be found. This thesis explores the design and development of a novel solution: a fully mobile colonoscopy robot called “RollerBall”. Unlike current passive diagnostic capsules, such as PillCam, this device uses wheels at the end of adjustable arms to provide locomotion through the colon, while providing a stable platform for the use of diagnostic and therapeutic tools. The work begins by reviewing relevant literature to better understand the problem and potential solutions. RollerBall is then introduced and its design described in detail. A robust prototype was then successfully fabricated using a 3D printing technique and its performance assessed in a series of benchtop experiments. These showed that the mechanisms functioned as intended and encouraged the further development of the concept. Next, the fundamental requirement of gaining traction on the colon was shown to be possible using hexagonal shaped, macro-scale tread patterns. A friction coefficient ranging between 0.29 and 0.55 was achieved with little trauma to the tissue substrate. The electronics hardware and control were then developed and evaluated in a series of tests in silicone tubes. An open-loop strategy was first used to establish the control algorithm to map the user inputs to motor outputs (wheel speeds). These tests showed the efficacy of the locomotion technique and the control algorithm used, but they highlighted the need for autonomy. To address this, feedback was included to automate the adjusting of the arm angle and amount of force applied by the device; a forward facing camera was also used to automate the orientation control by tracking a user-defined target. Force and orientation control were then combined to show that semi-autonomous control was possible and as a result, it was concluded that clinical use may be feasible in future developments.","abstract_has_math":false,"creators":["Norton, Joseph Christopher"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Neville, Anne","Culmer, Pete","Boyle, Jordan","Alazmani , Ali"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-01","date_published":"2017-01","updated_at":"2026-11-18T22:19:48Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.706010"],"render_values":[{"text":"uk.bl.ethos.706010","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["CoDIR (268519)"],"render_values":[{"text":"CoDIR (268519)","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000199815936"],"render_values":[{"text":"0000-0001-9981-5936","href":"https://orcid.org/0000-0001-9981-5936","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/16399/1/Norton_JC_Mechanical_Engineering_PhD_2017.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A16399","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Neville, Anne","Culmer, Pete","Boyle, Jordan","Alazmani , Ali"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["European Research Council"]},{"key":"dc:creator","label":"Author","values":["Norton, Joseph Christopher"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000199815936"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-01"]},{"key":"dc:date.issued","label":"Date","values":["2017-01"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Mechanical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/16399/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. Kaplan, G.G., The global burden of IBD: from 2015 to 2025. Nat Rev Gastroenterol Hepatol, 2015. 12(12): p. 720-727. 2. Luengo-Fernandez, R., et al., Economic burden of cancer across the European Union: a population-based cost analysis. The lancet oncology, 2013. 14(12): p. 1165-1174. 3. Liu, X., et al., Automated measurement of quality of mucosa inspection for colonoscopy. Procedia Computer Science, 2010. 1(1): p. 951-960. 4. Siegel, R., C. Desantis, and A. Jemal, Colorectal cancer statistics, 2014. CA Cancer J Clin, 2014. 64(2): p. 104-17. 5. CRUK. Bowel Cancer Statistics. 2016 December 2016]; Available from: http://www.cancerresearchuk.org/health-professional/cancer-statistics/statistics-by-cancer-type/bowel-cancer. 6. Gavin, D.R., et al., The national colonoscopy audit: a nationwide assessment of the quality and safety of colonoscopy in the UK. Gut, 2013. 62(2): p. 242-9. 7. Olympus. Colonoscope. [cited 2017; Available from: http://www.olympusamerica.com/presspass/press_pass_cut/images/msg/GIF-H180lg.jpg. 8. Alazmani, A., et al., Quantitative assessment of colorectal morphology: Implications for robotic colonoscopy. Medical Engineering & Physics, 2016. 38(2): p. 148-154. 9. Mitchell, R.M., et al., Successful colonoscopy; completion rates and reasons for incompletion. Ulster Med J, 2002. 71(1): p. 34-7. 10. Taylor, D.P., et al., Comparison of compliance for colorectal cancer screening and surveillance by colonoscopy based on risk. Genet Med, 2011. 13(8): p. 737-43. 11. Eickhoff, A., et al., Colon anatomy based on CT colonography and fluoroscopy: Impact on looping, straightening and ancillary manoeuvres in colonoscopy. Digestive and Liver Disease, 2010. 42(4): p. 291-296. 12. Sadahiro, S., et al., Analysis of Length and Surface-Area of Each Segment of the Large-Intestine According to Age, Sex and Physique. Surgical and Radiologic Anatomy, 1992. 14(3): p. 251-257. 13. Tytgat, G., Gastroenterological Endoscopy. 2010: Georg Thieme Verlag. 14. Paparo, F., et al., Computed tomography of the bowel: A prospective comparison study between four techniques. European Journal of Radiology, 2013. 82(1): p. E1-E10. 15. Strodel, W.E., et al., Therapeutic and Diagnostic Colonoscopy in Nonobstructive Colonic Dilatation. Annals of Surgery, 1983. 197(4): p. 416-421. 16. Marchesini, R., et al., Ex-Vivo Optical-Properties of Human Colon Tissue. Lasers in Surgery and Medicine, 1994. 15(4): p. 351-357. 17. Wang, K.D. and G.Z. Yan, Research on measurement and modeling of the gastro intestine's frictional characteristics. Measurement Science and Technology, 2009. 20(1): p. 015803. 18. Online, E.B., Large intestine: mucosa and musculature in humans. 2013: Encyclopædia Britannica. 19. Cunningham, D., et al., Colorectal cancer. The Lancet. 375(9719): p. 1030-1047. 20. Logan, R.F.A., et al., Outcomes of the Bowel Cancer Screening Programme (BCSP) in England after the first 1 million tests. Gut, 2012. 61(10): p. 1439-1446. 21. Martín-López, J.E., et al., Efficacy of CT colonography versus colonoscopy in screening for colorectal cancer. Radiología (English Edition), 2011. 53(4): p. 355-363. 22. Howard, K., et al., Preferences for CT colonography and colonoscopy as diagnostic tests for colorectal cancer: a discrete choice experiment. Value Health, 2011. 14(8): p. 1146-52. 192 23. van Gils, P., et al., A literature review of assumptions on test characteristics and adherence in economic evaluations of colonoscopy and CT-colonography screening. Eur J Cancer, 2009. 45(9): p. 1554-9. 24. Osama, A., H.H. Solieman, and H.A. Zaytoun, Role of CT virtual colonoscopy versus conventional colonoscopy in the evaluation of colonic polyps. The Egyptian Journal of Radiology and Nuclear Medicine, 2013. 44(3): p. 425-432. 25. Tapia-Siles, S.C., S. Coleman, and A. Cuschieri, Current state of micro-robots/devices as substitutes for screening colonoscopy: assessment based on technology readiness levels. Surgical Endoscopy, 2016. 30(2): p. 404-413. 26. Hafner, M., Conventional colonoscopy: Technique, indications, limits. European Journal of Radiology, 2007. 61(3): p. 409-414. 27. Seeff, L.C., et al., How many endoscopies are performed for colorectal cancer screening? Results from CDC's survey of endoscopic capacity. Gastroenterology, 2004. 127(6): p. 1670-1677. 28. Hopkins, J. Colonoscope in colon. [cited 2017; Available from: http://www.hopkinsmedicine.org/gastroenterology_hepatology/clinical_services/basic_endoscopy/colonoscopy.html. 29. Sedlack, R.E., Training to competency in colonoscopy: assessing and defining competency standards. Gastrointestinal Endoscopy, 2011. 74(2): p. 355-U259. 30. Britannica. Colonoscopy examination. [cited 2017; Available from: https://www.britannica.com/science/colonoscopy. 31. Sages. Colonoscope looping. [cited 2017; Available from: https://www.sages.org/image-category/fundamentals-diagnostic-colonoscopy/. 32. Barclay, R.L., et al., Colonoscopic withdrawal times and adenoma detection during screening colonoscopy. New England Journal of Medicine, 2006. 355(24): p. 2533-2541. 33. Harris, J.K., et al., Factors associated with the technical performance of colonoscopy: An EPAGE Study. Dig Liver Dis, 2007. 39(7): p. 678-89. 34. van Rijn, J.C., et al., Polyp miss rate determined by tandem colonoscopy: a systematic review. Am J Gastroenterol, 2006. 101(2): p. 343-50. 35. Gurudu, S.R. and F.C. Ramirez, Quality measurement and improvement in colonoscopy. Techniques in Gastrointestinal Endoscopy, 2012. 14(1): p. 21-28. 36. Singh, H., et al., Colonoscopy and its complications across a Canadian regional health authority. Gastrointest Endosc, 2009. 69(3 Pt 2): p. 665-71. 37. Rex, D.K., et al., Quality indicators for colonoscopy. Gastrointest Endosc, 2006. 63(4 Suppl): p. S16-28. 38. Bowles, C.J.A., et al., A prospective study of colonoscopy practice in the UK today: are we adequately prepared for national colorectal cancer screening tomorrow? Gut, 2004. 53(2): p. 277-283. 39. Liberman, A.S., I. Shrier, and P.H. Gordon, Injuries sustained by colorectal surgeons performing colonoscopy. Surg Endosc, 2005. 19(12): p. 1606-9. 40. Chung, Y.W., et al., Patient factors predictive of pain and difficulty during sedation-free colonoscopy: a prospective study in Korea. Dig Liver Dis, 2007. 39(9): p. 872-6. 41. Committee, A.S.o.P., et al., Complications of colonoscopy. Gastrointest Endosc, 2011. 74(4): p. 745-52. 42. Denis, B., et al., Harms of colonoscopy in a colorectal cancer screening programme with faecal occult blood test: a population-based cohort study. Dig Liver Dis, 2013. 45(6): p. 474-80. 43. Navaneethan, U., et al., Prevalence and risk factors for colonic perforation during colonoscopy in hospitalized inflammatory bowel disease patients. J Crohns Colitis, 2011. 5(3): p. 189-95. 193 44. Korman, L.Y., et al., Characterization of forces applied by endoscopists during colonoscopy by using a wireless colonoscopy force monitor. Gastrointest Endosc, 2010. 71(2): p. 327-34. 45. Leung, F.W., et al., A proof-of-principle, prospective, randomized, controlled trial demonstrating improved outcomes in scheduled unsedated colonoscopy by the water method. Gastrointest Endosc, 2010. 72(4): p. 693-700. 46. Pohl, J., et al., Water infusion for cecal intubation increases patient tolerance, but does not improve intubation of unsedated colonoscopies. Clin Gastroenterol Hepatol, 2011. 9(12): p. 1039-43 e1. 47. Leung, F.W., et al., Water-aided colonoscopy: a systematic review. Gastrointest Endosc, 2012. 76(3): p. 657-66. 48. Ransibrahmanakul, K., et al., Comparative Effectiveness of Water vs. Air Methods in Minimal Sedation Colonoscopy Performed by Supervised Trainees in the US - Randomized Controlled Trial. American Journal of Clinical Medicine, 2010. 7(3): p. 113-118. 49. Leung, J., et al., A randomized, controlled trial to confirm the beneficial effects of the water method on U.S. veterans undergoing colonoscopy with the option of on-demand sedation. Gastrointest Endosc, 2011. 73(1): p. 103-10. 50. Friedland, S., T. Kaltenbach, and R. Soetikno, Use of The Double Balloon Enteroscope System to Complete Incomplete Colonoscopy. Techniques in Gastrointestinal Endoscopy, 2008. 10(3): p. 124-127. 51. Lee, D.W., et al., Use of a variable-stiffness colonoscope decreases the dose of patient-controlled sedation during colonoscopy: a randomized comparison of 3 colonoscopes. Gastrointest Endosc, 2007. 65(3): p. 424-9. 52. Hewett, D.G. and D.K. Rex, Cap-fitted colonoscopy: a randomized, tandem colonoscopy study of adenoma miss rates. Gastrointest Endosc, 2010. 72(4): p. 775-81. 53. DeMarco, D.C., et al., Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group. Gastrointest Endosc, 2010. 71(3): p. 542-50. 54. Ng, W.S., et al., Development of a Robotic Colonoscope. Digestive Endoscopy, 2000. 12: p. 131 - 135. 55. Kim, B., et al., Inchworm-like colonoscopic robot with hollow body and steering device. Jsme International Journal Series C-Mechanical Systems Machine Elements and Manufacturing, 2006. 49(1): p. 205-212. 56. Vucelic, B., et al., The aer-o-scope: proof of concept of a pneumatic, skill-independent, self-propelling, self-navigating colonoscope. Gastroenterology, 2006. 130(3): p. 672-7. 57. Groth, S., et al., High cecal intubation rates with a new computer-assisted colonoscope: a feasibility study. Am J Gastroenterol, 2011. 106(6): p. 1075-80. 58. Hawes, R.H., Endoscopic innovations. Gastrointest Endosc, 2013. 78(3): p. 410-3. 59. Menciassi, A., M. Quirini, and P. Dario, Microrobotics for future gastrointestinal endoscopy. Minim Invasive Ther Allied Technol, 2007. 16(2): p. 91-100. 60. Van Gossum, A., et al., Capsule Endoscopy versus Colonoscopy for the Detection of Polyps and Cancer. New England Journal of Medicine, 2009. 361(3): p. 264-270. 61. Ciuti, G., A. Menciassi, and P. Dario, Capsule Endoscopy: From Current Achievements to Open Challenges. Biomedical Engineering, IEEE Reviews in, 2011. 4: p. 59-72. 62. Arezzo, A., et al., Experimental assessment of a novel robotically-driven endoscopic capsule compared to traditional colonoscopy. Dig Liver Dis, 2013. 45(8): p. 657-62. 63. Kassim, I., et al., Locomotion techniques for robotic colonoscopy. Ieee Engineering in Medicine and Biology Magazine, 2006. 25(3): p. 49-56. 194 64. Carta, R., et al., Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection. Biosens Bioelectron, 2009. 25(4): p. 845-51. 65. Kennedy, G.C. and J.K. Holt. Developing a high efficiency means of propulsion for underwater vehicles. in Southcon/95. Conference Record. 1995. 66. Holt, J.K. and D.G. White. High efficiency, counter-rotating ring thruster for underwater vehicles. in Autonomous Underwater Vehicle Technology, 1994. AUV '94., Proceedings of the 1994 Symposium on. 1994. 67. Chen, B., et al., Research on the Kinematic Properties of a Sperm-Like Swimming Micro Robot. Journal of Bionic Engineering, 2010. 7: p. S123-S129. 68. Ha, N.S. and N.S. Goo, Propulsion Modeling and Analysis of a Biomimetic Swimmer. Journal of Bionic Engineering, 2010. 7(3): p. 259-266. 69. Mazumdar, A., et al. A compact, maneuverable, underwater robot for direct inspection of nuclear power piping systems. in Robotics and Automation (ICRA), 2012 IEEE International Conference on. 2012. 70. Korde, U.A., Study of a jet-propulsion method for an underwater vehicle. Ocean Engineering, 2004. 31(10): p. 1205-1218. 71. Mohseni, K., Pulsatile vortex generators for low-speed maneuvering of small underwater vehicles. Ocean Engineering, 2006. 33(16): p. 2209-2223. 72. Polsenberg-Thomas, A.M., J. Burdick, and K. Mohseni. An experimental study of voice-coil driven synthetic jet propulsion for underwater vehicles. in OCEANS, 2005. Proceedings of MTS/IEEE. 2005. 73. Shuxiang, G., et al. Underwater Swimming Micro Robot Using IPMC Actuator. in Mechatronics and Automation, Proceedings of the 2006 IEEE International Conference on. 2006. 74. Wang, Z., et al., A micro-robot fish with embedded SMA wire actuated flexible biomimetic fin. Sensors and Actuators A: Physical, 2008. 144(2): p. 354-360. 75. Takagi, K., et al. Development of a Rajiform Swimming Robot using Ionic Polymer Artificial Muscles. in Intelligent Robots and Systems, 2006 IEEE/RSJ International Conference on. 2006. 76. Kosa, G., M. Shoham, and M. Zaaroor. Analysis of a Swimming Micro Robot. in Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on. 2006. 77. Carta, R., et al., A multi-coil inductive powering system for an endoscopic capsule with vibratory actuation. Sensors and Actuators A: Physical, 2011. 172(1): p. 253-258. 78. Hong, D.W., M. Ingram, and D. Lahr, Whole Skin Locomotion Inspired by Amoeboid Motility Mechanisms. Journal of Mechanisms and Robotics, 2009. 1(1): p. 011015. 79. Sliker, L.J., et al., Surgical evaluation of a novel tethered robotic capsule endoscope using micro-patterned treads. Surg Endosc, 2012. 26(10): p. 2862-9. 80. Young-Sik, K., et al. Design and motion planning of a two-moduled indoor pipeline inspection robot. in Robotics and Automation, 2008. ICRA 2008. IEEE International Conference on. 2008. 81. Jungwan, P., K. Taehyun, and Y. Hyunseok. Development of an actively adaptable in-pipe robot. in Mechatronics, 2009. ICM 2009. IEEE International Conference on. 2009. 82. Liu, Q., T. Ren, and Y. Chen, Characteristic analysis of a novel in-pipe driving robot. Mechatronics, 2013. 23(4): p. 419-428. 83. Lambrecht, B.G.A., A.D. Horchler, and R.D. Quinn. A Small, Insect-Inspired Robot that Runs and Jumps. in Robotics and Automation, 2005. ICRA 2005. Proceedings of the 2005 IEEE International Conference on. 2005. 84. Kim, Y.T. and D.E. Kim, Novel Propelling Mechanisms Based on Frictional Interaction for Endoscope Robot. Tribology Transactions, 2010. 53(2): p. 203-211. 195 85. Crespi, A. and A.J. Ijspeert, Online Optimization of Swimming and Crawling in an Amphibious Snake Robot. Robotics, IEEE Transactions on, 2008. 24(1): p. 75-87. 86. Dario, P., et al., Modeling and Experimental Validation of the Locomotion of Endoscopic Robots in the Colon. The International Journal of Robotics Research, 2004. 23(4): p. 549-556. 87. Phee, L., et al., Analysis and development of locomotion devices for the gastrointestinal tract. Biomedical Engineering, IEEE Transactions on, 2002. 49(6): p. 613-616. 88. Kundong, W., et al. Squirm robot with full bellow skin for colonoscopy. in Robotics and Biomimetics (ROBIO), 2010 IEEE International Conference on. 2010. 89. Karagozler, M.E., et al. Miniature Endoscopic Capsule Robot using Biomimetic Micro-Patterned Adhesives. in Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on. 2006. 90. Stefanini, C., Modeling and Experiments on a Legged Microrobot Locomoting in a Tubular, Compliant and Slippery Environment. The International Journal of Robotics Research, 2006. 25(5-6): p. 551-560. 91. Weida, L., et al. A Novel Locomotion Principle for Endoscopic Robot. in Mechatronics and Automation, Proceedings of the 2006 IEEE International Conference on. 2006. 92. Quirini, M., et al. Design of a Pill-Sized 12-legged Endoscopic Capsule Robot. in Robotics and Automation, 2007 IEEE International Conference on. 2007. 93. Kim, H.M., et al., Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos). Gastrointest Endosc, 2010. 72(2): p. 381-7. 94. Heijnsdijk, E.A., et al., Inter- and intraindividual variabilities of perforation forces of human and pig bowel tissue. Surg Endosc, 2003. 17(12): p. 1923-6. 95. Moshkowitz, M., et al., A novel device for rapid cleaning of poorly prepared colons. Endoscopy, 2010. 42(10): p. 834-6. 96. Lee, S.H., et al., An optimal micropatterned end-effecter for enhancing frictional force on large intestinal surface. ACS Appl Mater Interfaces, 2010. 2(5): p. 1308-16. 97. Paparo, F., et al., Computed tomography of the bowel: a prospective comparison study between four techniques. Eur J Radiol, 2013. 82(1): p. e1-e10. 98. Gao, P., et al., Microgroove cushion of robotic endoscope for active locomotion in the gastrointestinal tract. Int J Med Robot, 2012. 8(4): p. 398-406. 99. Buselli, E., et al., Evaluation of friction enhancement through soft polymer micro-patterns in active capsule endoscopy. Measurement Science and Technology, 2010. 21(10): p. 105802. 100. Dodou, D., P. Breedveld, and P.A. Wieringa, Mucoadhesives in the gastrointestinal tract: revisiting the literature for novel applications. Eur J Pharm Biopharm, 2005. 60(1): p. 1-16. 101. Smart, J.D., The basics and underlying mechanisms of mucoadhesion. Adv Drug Deliv Rev, 2005. 57(11): p. 1556-68. 102. Dodou, D., et al., Mucoadhesive films inside the colonic tube: performance in a three-dimensional world. J R Soc Interface, 2008. 5(28): p. 1353-62. 103. Dodou, D., P. Breedveld, and P.A. Wieringa, Stick, unstick, restick sticky films in the colon. Minim Invasive Ther Allied Technol, 2006. 15(5): p. 286-95. 104. Dodou, D., P. Breedveld, and P.A. Wieringa, Friction manipulation for intestinal locomotion. Minim Invasive Ther Allied Technol, 2005. 14(3): p. 188-97. 105. Tramacere, F., et al., The morphology and adhesion mechanism of Octopus vulgaris suckers. PLoS One, 2013. 8(6): p. e65074. 106. Ge, D., et al., Quantitative study on the attachment and detachment of a passive suction cup. Vacuum, 2015. 116: p. 13-20. 196 107. Patronik, N.A., et al. Improved Traction for a Mobile Robot Traveling on the Heart. in 2006 International Conference of the IEEE Engineering in Medicine and Biology Society. 2006. 108. Lyle, A.B., J.T. Luftig, and M.E. Rentschler, A tribological investigation of the small bowel lumen surface. Tribology International, 2013. 62: p. 171-176. 109. Egorov, V.I., et al., Mechanical properties of the human gastrointestinal tract. Journal of Biomechanics, 2002. 35(10): p. 1417-1425. 110. Christensen, M.B., K. Oberg, and J.C. Wolchok, Tensile properties of the rectal and sigmoid colon: a comparative analysis of human and porcine tissue. Springerplus, 2015. 4: p. 142. 111. Higa, M., et al., Passive mechanical properties of large intestine under in vivo and in vitro compression. Med Eng Phys, 2007. 29(8): p. 840-4. 112. Shamsuddin, A.M., P.C. Phelps, and B.F. Trump, Human Large Intestinal Epithelium - Light-Microscopy, Histochemistry, and Ultrastructure. Human Pathology, 1982. 13(9): p. 790-803. 113. Cone, R.A., Barrier properties of mucus. Adv Drug Deliv Rev, 2009. 61(2): p. 75-85. 114. Gustafsson, J.K., et al., An ex vivo method for studying mucus formation, properties, and thickness in human colonic biopsies and mouse small and large intestinal explants. Am J Physiol Gastrointest Liver Physiol, 2012. 302(4): p. G430-8. 115. Lai, S.K., et al., Micro- and macrorheology of mucus. Adv Drug Deliv Rev, 2009. 61(2): p. 86-100. 116. Finkelstone, L., E. Wolf, and M.W. Stein, Etiology of small bowel thickening on computed tomography. Canadian Journal of Gastroenterology, 2012. 26(12): p. 897-901. 117. Kim, D.E. and Y.T. Kim, Biotribological investigation of a multi-tube foot for traction generation in a medical microrobot. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2009. 223(6): p. 677-686. 118. Atuma, C., et al., The adherent gastrointestinal mucus gel layer: thickness and physical state in vivo. American Journal of Physiology-Gastrointestinal and Liver Physiology, 2001. 280(5): p. G922-G929. 119. Kim, J.S., et al., Experimental investigation of frictional and viscoelastic properties of intestine for microendoscope application. Tribology Letters, 2006. 22(2): p. 143-149. 120. Lyle, A.B., et al., Preliminary Friction Force Measurements on Small Bowel Lumen When Eliminating Sled Edge Effects. Tribology Letters, 2013. 51(3): p. 377-383. 121. Zhang, C., et al., Modeling of Velocity-dependent Frictional Resistance of a Capsule Robot Inside an Intestine. Tribology Letters, 2012. 47(2): p. 295-301. 122. Accoto, D., et al. Measurements of the frictional properties of the gastrointestinal tract. in World Tribology Congress. 2001. 123. Chen, H., et al., Bioinspired Surface for Surgical Graspers Based on the Strong Wet Friction of Tree Frog Toe Pads. ACS Appl Mater Interfaces, 2015. 7(25): p. 13987-95. 124. Barnes, W.J., et al., Elastic modulus of tree frog adhesive toe pads. J Comp Physiol A Neuroethol Sens Neural Behav Physiol, 2011. 197(10): p. 969-78. 125. Varenberg, M. and S.N. Gorb, Hexagonal Surface Micropattern for Dry and Wet Friction. Advanced Materials, 2009. 21(4): p. 483-486. 126. Drotlef, D.M., et al., Morphological studies of the toe pads of the rock frog, Staurois parvus (family: Ranidae) and their relevance to the development of new biomimetically inspired reversible adhesives. Interface Focus, 2015. 5(1): p. 20140036. 127. Drotlef, D.-M., et al., Insights into the Adhesive Mechanisms of Tree Frogs using Artificial Mimics. Advanced Functional Materials, 2013. 23(9): p. 1137-1146. 128. Iturri, J., et al., Torrent Frog-Inspired Adhesives: Attachment to Flooded Surfaces. Advanced Functional Materials, 2015. 25(10): p. 1499-1505. 197 129. Murarash, B., Y. Itovich, and M. Varenberg, Tuning elastomer friction by hexagonal surface patterning. Soft Matter, 2011. 7(12): p. 5553. 130. Persson, B.N.J., Wet adhesion with application to tree frog adhesive toe pads and tires. Journal of Physics: Condensed Matter, 2007. 19(37): p. 376110. 131. Cho, J.R., et al., Numerical investigation of hydroplaning characteristics of three-dimensional patterned tire. European Journal of Mechanics - A/Solids, 2006. 25(6): p. 914-926. 132. Fwa, T., et al., Effectiveness of Tire-Tread Patterns in Reducing the Risk of Hydroplaning. Transportation Research Record: Journal of the Transportation Research Board, 2009. 2094: p. 91-102. 133. Persson, B.N.J., et al., Rubber friction on wet and dry road surfaces: The sealing effect. Physical Review B, 2005. 71(3). 134. Gupta, R. and J. Frechette, Measurement and scaling of hydrodynamic interactions in the presence of draining channels. Langmuir, 2012. 28(41): p. 14703-12. 135. Glass, P., E. Cheung, and M. Sitti, A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives. IEEE Trans Biomed Eng, 2008. 55(12): p. 2759-67. 136. Majidi, C., Soft robotics: a perspective—current trends and prospects for the future. Soft Robotics, 2014. 1(1): p. 5-11. 137. Yoshida, H., Y. Morita, and K. Ikeuchi, Biological lubrication of hydrated surface layer in small intestine. Tribol. Interface Eng. Ser.: Tribol. Res. Des. Eng. Syst, 2003. 41: p. 425-428. 138. Gong, J.P., Friction and lubrication of hydrogels—its richness and complexity. Soft Matter, 2006. 2(7): p. 544-552. 139. Kararli, T.T., Comparison of the gastrointestinal anatomy, physiology, and biochemistry of humans and commonly used laboratory animals. Biopharmaceutics & Drug Disposition, 1995. 16(5): p. 351-380. 140. Olakanmi, E.O., R.F. Cochrane, and K.W. Dalgarno, A review on selective laser sintering/melting (SLS/SLM) of aluminium alloy powders: Processing, microstructure, and properties. Progress in Materials Science, 2015. 74: p. 401-477. 141. Rentschler, M.E., S.M. Farritor, and K.D. Iagnemma, Mechanical Design of Robotic In Vivo Wheeled Mobility. Journal of Mechanical Design, 2007. 129(10): p. 1037. 142. Heijnsdijk, E.A.M., et al., Slip and damage properties of jaws of laparoscopic graspers. Surgical Endoscopy and Other Interventional Techniques, 2004. 18(6): p. 974-979. 143. Tur, J.M.M. and W. Garthwaite, Robotic devices for water main in‐pipe inspection: A survey. Journal of Field Robotics, 2010. 27(4): p. 491-508. 144. Majidi, C., Soft Robotics: A Perspective—Current Trends and Prospects for the Future. Soft Robotics, 2013. 1(P): p. 5-11. 145. Kim, S., C. Laschi, and B. Trimmer, Soft robotics: a bioinspired evolution in robotics. Trends Biotechnol, 2013. 31(5): p. 287-94. 146. Pfeifer, R., M. Lungarella, and F. Iida, The challenges ahead for bio-inspired 'soft' robotics. Communications of the ACM, 2012. 55(11): p. 76. 147. Lin, H.T., G.G. Leisk, and B. Trimmer, GoQBot: a caterpillar-inspired soft-bodied rolling robot. Bioinspir Biomim, 2011. 6(2): p. 026007. 148. Shepherd, R.F., et al., Multigait soft robot. Proceedings of the National Academy of Sciences, 2011. 108(51): p. 20400-20403. 149. Ying, S., et al., Variable Stiffness Structures Utilizing Fluidic Flexible Matrix Composites. Journal of Intelligent Material Systems and Structures, 2008. 20(4): p. 443-456. 198 150. Jiang, A., et al. Design of a variable stiffness flexible manipulator with composite granular jamming and membrane coupling. in Intelligent Robots and Systems (IROS), 2012 IEEE/RSJ International Conference on. 2012. 151. Yong-Jae, K., et al., A Novel Layer Jamming Mechanism With Tunable Stiffness Capability for Minimally Invasive Surgery. Robotics, IEEE Transactions on, 2013. 29(4): p. 1031-1042. 152. Wagner, N.J. and J.F. Brady, Shear thickening in colloidal dispersions. Physics Today, 2009. 62(10): p. 27-32. 153. Kuder, I.K., et al., Variable stiffness material and structural concepts for morphing applications. Progress in Aerospace Sciences, 2013. 63: p. 33-55. 154. Stokes, A.A., et al., A Hybrid Combining Hard and Soft Robots. Soft Robotics, 2014. 1(1): p. 70-74. 155. Laschi, C., et al., Soft Robot Arm Inspired by the Octopus. Advanced Robotics, 2012. 26(7): p. 709-727."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.706010"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["CoDIR (268519)"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/16399/1/Norton_JC_Mechanical_Engineering_PhD_2017.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The conventional colonoscopy is a common procedure used to access the colon. Despite it being considered the Gold Standard procedure for colorectal cancer diagnosis and treatment, it has a number of major drawbacks, including high patient discomfort, infrequent but serious complications and high skill required to perform the procedure. There are a number of potential alternatives to the conventional colonoscopy, from augmenting the colonoscope to using Computed Tomography Colonography (CTC) - a completely non-invasive method. However, a truly effective, all-round alternative has yet to be found. This thesis explores the design and development of a novel solution: a fully mobile colonoscopy robot called “RollerBall”. Unlike current passive diagnostic capsules, such as PillCam, this device uses wheels at the end of adjustable arms to provide locomotion through the colon, while providing a stable platform for the use of diagnostic and therapeutic tools. The work begins by reviewing relevant literature to better understand the problem and potential solutions. RollerBall is then introduced and its design described in detail. A robust prototype was then successfully fabricated using a 3D printing technique and its performance assessed in a series of benchtop experiments. These showed that the mechanisms functioned as intended and encouraged the further development of the concept. Next, the fundamental requirement of gaining traction on the colon was shown to be possible using hexagonal shaped, macro-scale tread patterns. A friction coefficient ranging between 0.29 and 0.55 was achieved with little trauma to the tissue substrate. The electronics hardware and control were then developed and evaluated in a series of tests in silicone tubes. An open-loop strategy was first used to establish the control algorithm to map the user inputs to motor outputs (wheel speeds). These tests showed the efficacy of the locomotion technique and the control algorithm used, but they highlighted the need for autonomy. To address this, feedback was included to automate the adjusting of the arm angle and amount of force applied by the device; a forward facing camera was also used to automate the orientation control by tracking a user-defined target. Force and orientation control were then combined to show that semi-autonomous control was possible and as a result, it was concluded that clinical use may be feasible in future developments."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["The Design and Development of a Mobile Colonoscopy Robot"]}]}],"canonical_facts":{"dc:contributor.advisor":["Neville, Anne","Culmer, Pete","Boyle, Jordan","Alazmani , Ali"],"dc:contributor.sponsor":["European Research Council"],"dc:creator":["Norton, Joseph Christopher"],"dc:date":["2017-01"],"dc:date.issued":["2017-01"],"dc:description.abstract":["The conventional colonoscopy is a common procedure used to access the colon. Despite it being considered the Gold Standard procedure for colorectal cancer diagnosis and treatment, it has a number of major drawbacks, including high patient discomfort, infrequent but serious complications and high skill required to perform the procedure. There are a number of potential alternatives to the conventional colonoscopy, from augmenting the colonoscope to using Computed Tomography Colonography (CTC) - a completely non-invasive method. However, a truly effective, all-round alternative has yet to be found. This thesis explores the design and development of a novel solution: a fully mobile colonoscopy robot called “RollerBall”. Unlike current passive diagnostic capsules, such as PillCam, this device uses wheels at the end of adjustable arms to provide locomotion through the colon, while providing a stable platform for the use of diagnostic and therapeutic tools. The work begins by reviewing relevant literature to better understand the problem and potential solutions. RollerBall is then introduced and its design described in detail. A robust prototype was then successfully fabricated using a 3D printing technique and its performance assessed in a series of benchtop experiments. These showed that the mechanisms functioned as intended and encouraged the further development of the concept. Next, the fundamental requirement of gaining traction on the colon was shown to be possible using hexagonal shaped, macro-scale tread patterns. A friction coefficient ranging between 0.29 and 0.55 was achieved with little trauma to the tissue substrate. The electronics hardware and control were then developed and evaluated in a series of tests in silicone tubes. An open-loop strategy was first used to establish the control algorithm to map the user inputs to motor outputs (wheel speeds). These tests showed the efficacy of the locomotion technique and the control algorithm used, but they highlighted the need for autonomy. To address this, feedback was included to automate the adjusting of the arm angle and amount of force applied by the device; a forward facing camera was also used to automate the orientation control by tracking a user-defined target. Force and orientation control were then combined to show that semi-autonomous control was possible and as a result, it was concluded that clinical use may be feasible in future developments."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.706010"],"dc:identifier.grantnumber":["CoDIR (268519)"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/16399/1/Norton_JC_Mechanical_Engineering_PhD_2017.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["School of Mechanical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/16399/"],"dc:relation.references":["1. Kaplan, G.G., The global burden of IBD: from 2015 to 2025. Nat Rev Gastroenterol Hepatol, 2015. 12(12): p. 720-727. 2. Luengo-Fernandez, R., et al., Economic burden of cancer across the European Union: a population-based cost analysis. The lancet oncology, 2013. 14(12): p. 1165-1174. 3. Liu, X., et al., Automated measurement of quality of mucosa inspection for colonoscopy. Procedia Computer Science, 2010. 1(1): p. 951-960. 4. Siegel, R., C. Desantis, and A. Jemal, Colorectal cancer statistics, 2014. CA Cancer J Clin, 2014. 64(2): p. 104-17. 5. CRUK. Bowel Cancer Statistics. 2016 December 2016]; Available from: http://www.cancerresearchuk.org/health-professional/cancer-statistics/statistics-by-cancer-type/bowel-cancer. 6. Gavin, D.R., et al., The national colonoscopy audit: a nationwide assessment of the quality and safety of colonoscopy in the UK. Gut, 2013. 62(2): p. 242-9. 7. Olympus. Colonoscope. [cited 2017; Available from: http://www.olympusamerica.com/presspass/press_pass_cut/images/msg/GIF-H180lg.jpg. 8. Alazmani, A., et al., Quantitative assessment of colorectal morphology: Implications for robotic colonoscopy. Medical Engineering & Physics, 2016. 38(2): p. 148-154. 9. Mitchell, R.M., et al., Successful colonoscopy; completion rates and reasons for incompletion. Ulster Med J, 2002. 71(1): p. 34-7. 10. Taylor, D.P., et al., Comparison of compliance for colorectal cancer screening and surveillance by colonoscopy based on risk. Genet Med, 2011. 13(8): p. 737-43. 11. Eickhoff, A., et al., Colon anatomy based on CT colonography and fluoroscopy: Impact on looping, straightening and ancillary manoeuvres in colonoscopy. Digestive and Liver Disease, 2010. 42(4): p. 291-296. 12. Sadahiro, S., et al., Analysis of Length and Surface-Area of Each Segment of the Large-Intestine According to Age, Sex and Physique. Surgical and Radiologic Anatomy, 1992. 14(3): p. 251-257. 13. Tytgat, G., Gastroenterological Endoscopy. 2010: Georg Thieme Verlag. 14. Paparo, F., et al., Computed tomography of the bowel: A prospective comparison study between four techniques. European Journal of Radiology, 2013. 82(1): p. E1-E10. 15. Strodel, W.E., et al., Therapeutic and Diagnostic Colonoscopy in Nonobstructive Colonic Dilatation. Annals of Surgery, 1983. 197(4): p. 416-421. 16. Marchesini, R., et al., Ex-Vivo Optical-Properties of Human Colon Tissue. Lasers in Surgery and Medicine, 1994. 15(4): p. 351-357. 17. Wang, K.D. and G.Z. Yan, Research on measurement and modeling of the gastro intestine's frictional characteristics. Measurement Science and Technology, 2009. 20(1): p. 015803. 18. Online, E.B., Large intestine: mucosa and musculature in humans. 2013: Encyclopædia Britannica. 19. Cunningham, D., et al., Colorectal cancer. The Lancet. 375(9719): p. 1030-1047. 20. Logan, R.F.A., et al., Outcomes of the Bowel Cancer Screening Programme (BCSP) in England after the first 1 million tests. Gut, 2012. 61(10): p. 1439-1446. 21. Martín-López, J.E., et al., Efficacy of CT colonography versus colonoscopy in screening for colorectal cancer. Radiología (English Edition), 2011. 53(4): p. 355-363. 22. Howard, K., et al., Preferences for CT colonography and colonoscopy as diagnostic tests for colorectal cancer: a discrete choice experiment. Value Health, 2011. 14(8): p. 1146-52. 192 23. van Gils, P., et al., A literature review of assumptions on test characteristics and adherence in economic evaluations of colonoscopy and CT-colonography screening. Eur J Cancer, 2009. 45(9): p. 1554-9. 24. Osama, A., H.H. Solieman, and H.A. Zaytoun, Role of CT virtual colonoscopy versus conventional colonoscopy in the evaluation of colonic polyps. The Egyptian Journal of Radiology and Nuclear Medicine, 2013. 44(3): p. 425-432. 25. Tapia-Siles, S.C., S. Coleman, and A. Cuschieri, Current state of micro-robots/devices as substitutes for screening colonoscopy: assessment based on technology readiness levels. Surgical Endoscopy, 2016. 30(2): p. 404-413. 26. Hafner, M., Conventional colonoscopy: Technique, indications, limits. European Journal of Radiology, 2007. 61(3): p. 409-414. 27. Seeff, L.C., et al., How many endoscopies are performed for colorectal cancer screening? Results from CDC's survey of endoscopic capacity. Gastroenterology, 2004. 127(6): p. 1670-1677. 28. Hopkins, J. Colonoscope in colon. [cited 2017; Available from: http://www.hopkinsmedicine.org/gastroenterology_hepatology/clinical_services/basic_endoscopy/colonoscopy.html. 29. Sedlack, R.E., Training to competency in colonoscopy: assessing and defining competency standards. Gastrointestinal Endoscopy, 2011. 74(2): p. 355-U259. 30. Britannica. Colonoscopy examination. [cited 2017; Available from: https://www.britannica.com/science/colonoscopy. 31. Sages. Colonoscope looping. [cited 2017; Available from: https://www.sages.org/image-category/fundamentals-diagnostic-colonoscopy/. 32. Barclay, R.L., et al., Colonoscopic withdrawal times and adenoma detection during screening colonoscopy. New England Journal of Medicine, 2006. 355(24): p. 2533-2541. 33. Harris, J.K., et al., Factors associated with the technical performance of colonoscopy: An EPAGE Study. Dig Liver Dis, 2007. 39(7): p. 678-89. 34. van Rijn, J.C., et al., Polyp miss rate determined by tandem colonoscopy: a systematic review. Am J Gastroenterol, 2006. 101(2): p. 343-50. 35. Gurudu, S.R. and F.C. Ramirez, Quality measurement and improvement in colonoscopy. Techniques in Gastrointestinal Endoscopy, 2012. 14(1): p. 21-28. 36. Singh, H., et al., Colonoscopy and its complications across a Canadian regional health authority. Gastrointest Endosc, 2009. 69(3 Pt 2): p. 665-71. 37. Rex, D.K., et al., Quality indicators for colonoscopy. Gastrointest Endosc, 2006. 63(4 Suppl): p. S16-28. 38. Bowles, C.J.A., et al., A prospective study of colonoscopy practice in the UK today: are we adequately prepared for national colorectal cancer screening tomorrow? Gut, 2004. 53(2): p. 277-283. 39. Liberman, A.S., I. Shrier, and P.H. Gordon, Injuries sustained by colorectal surgeons performing colonoscopy. Surg Endosc, 2005. 19(12): p. 1606-9. 40. Chung, Y.W., et al., Patient factors predictive of pain and difficulty during sedation-free colonoscopy: a prospective study in Korea. Dig Liver Dis, 2007. 39(9): p. 872-6. 41. Committee, A.S.o.P., et al., Complications of colonoscopy. Gastrointest Endosc, 2011. 74(4): p. 745-52. 42. Denis, B., et al., Harms of colonoscopy in a colorectal cancer screening programme with faecal occult blood test: a population-based cohort study. Dig Liver Dis, 2013. 45(6): p. 474-80. 43. Navaneethan, U., et al., Prevalence and risk factors for colonic perforation during colonoscopy in hospitalized inflammatory bowel disease patients. J Crohns Colitis, 2011. 5(3): p. 189-95. 193 44. Korman, L.Y., et al., Characterization of forces applied by endoscopists during colonoscopy by using a wireless colonoscopy force monitor. Gastrointest Endosc, 2010. 71(2): p. 327-34. 45. Leung, F.W., et al., A proof-of-principle, prospective, randomized, controlled trial demonstrating improved outcomes in scheduled unsedated colonoscopy by the water method. Gastrointest Endosc, 2010. 72(4): p. 693-700. 46. Pohl, J., et al., Water infusion for cecal intubation increases patient tolerance, but does not improve intubation of unsedated colonoscopies. Clin Gastroenterol Hepatol, 2011. 9(12): p. 1039-43 e1. 47. Leung, F.W., et al., Water-aided colonoscopy: a systematic review. Gastrointest Endosc, 2012. 76(3): p. 657-66. 48. Ransibrahmanakul, K., et al., Comparative Effectiveness of Water vs. Air Methods in Minimal Sedation Colonoscopy Performed by Supervised Trainees in the US - Randomized Controlled Trial. American Journal of Clinical Medicine, 2010. 7(3): p. 113-118. 49. Leung, J., et al., A randomized, controlled trial to confirm the beneficial effects of the water method on U.S. veterans undergoing colonoscopy with the option of on-demand sedation. Gastrointest Endosc, 2011. 73(1): p. 103-10. 50. Friedland, S., T. Kaltenbach, and R. Soetikno, Use of The Double Balloon Enteroscope System to Complete Incomplete Colonoscopy. Techniques in Gastrointestinal Endoscopy, 2008. 10(3): p. 124-127. 51. Lee, D.W., et al., Use of a variable-stiffness colonoscope decreases the dose of patient-controlled sedation during colonoscopy: a randomized comparison of 3 colonoscopes. Gastrointest Endosc, 2007. 65(3): p. 424-9. 52. Hewett, D.G. and D.K. Rex, Cap-fitted colonoscopy: a randomized, tandem colonoscopy study of adenoma miss rates. Gastrointest Endosc, 2010. 72(4): p. 775-81. 53. DeMarco, D.C., et al., Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group. Gastrointest Endosc, 2010. 71(3): p. 542-50. 54. Ng, W.S., et al., Development of a Robotic Colonoscope. Digestive Endoscopy, 2000. 12: p. 131 - 135. 55. Kim, B., et al., Inchworm-like colonoscopic robot with hollow body and steering device. Jsme International Journal Series C-Mechanical Systems Machine Elements and Manufacturing, 2006. 49(1): p. 205-212. 56. Vucelic, B., et al., The aer-o-scope: proof of concept of a pneumatic, skill-independent, self-propelling, self-navigating colonoscope. Gastroenterology, 2006. 130(3): p. 672-7. 57. Groth, S., et al., High cecal intubation rates with a new computer-assisted colonoscope: a feasibility study. Am J Gastroenterol, 2011. 106(6): p. 1075-80. 58. Hawes, R.H., Endoscopic innovations. Gastrointest Endosc, 2013. 78(3): p. 410-3. 59. Menciassi, A., M. Quirini, and P. Dario, Microrobotics for future gastrointestinal endoscopy. Minim Invasive Ther Allied Technol, 2007. 16(2): p. 91-100. 60. Van Gossum, A., et al., Capsule Endoscopy versus Colonoscopy for the Detection of Polyps and Cancer. New England Journal of Medicine, 2009. 361(3): p. 264-270. 61. Ciuti, G., A. Menciassi, and P. Dario, Capsule Endoscopy: From Current Achievements to Open Challenges. Biomedical Engineering, IEEE Reviews in, 2011. 4: p. 59-72. 62. Arezzo, A., et al., Experimental assessment of a novel robotically-driven endoscopic capsule compared to traditional colonoscopy. Dig Liver Dis, 2013. 45(8): p. 657-62. 63. Kassim, I., et al., Locomotion techniques for robotic colonoscopy. Ieee Engineering in Medicine and Biology Magazine, 2006. 25(3): p. 49-56. 194 64. Carta, R., et al., Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection. Biosens Bioelectron, 2009. 25(4): p. 845-51. 65. Kennedy, G.C. and J.K. Holt. Developing a high efficiency means of propulsion for underwater vehicles. in Southcon/95. Conference Record. 1995. 66. Holt, J.K. and D.G. White. High efficiency, counter-rotating ring thruster for underwater vehicles. in Autonomous Underwater Vehicle Technology, 1994. AUV '94., Proceedings of the 1994 Symposium on. 1994. 67. Chen, B., et al., Research on the Kinematic Properties of a Sperm-Like Swimming Micro Robot. Journal of Bionic Engineering, 2010. 7: p. S123-S129. 68. Ha, N.S. and N.S. Goo, Propulsion Modeling and Analysis of a Biomimetic Swimmer. Journal of Bionic Engineering, 2010. 7(3): p. 259-266. 69. Mazumdar, A., et al. A compact, maneuverable, underwater robot for direct inspection of nuclear power piping systems. in Robotics and Automation (ICRA), 2012 IEEE International Conference on. 2012. 70. Korde, U.A., Study of a jet-propulsion method for an underwater vehicle. Ocean Engineering, 2004. 31(10): p. 1205-1218. 71. Mohseni, K., Pulsatile vortex generators for low-speed maneuvering of small underwater vehicles. Ocean Engineering, 2006. 33(16): p. 2209-2223. 72. Polsenberg-Thomas, A.M., J. Burdick, and K. Mohseni. An experimental study of voice-coil driven synthetic jet propulsion for underwater vehicles. in OCEANS, 2005. Proceedings of MTS/IEEE. 2005. 73. Shuxiang, G., et al. Underwater Swimming Micro Robot Using IPMC Actuator. in Mechatronics and Automation, Proceedings of the 2006 IEEE International Conference on. 2006. 74. Wang, Z., et al., A micro-robot fish with embedded SMA wire actuated flexible biomimetic fin. Sensors and Actuators A: Physical, 2008. 144(2): p. 354-360. 75. Takagi, K., et al. Development of a Rajiform Swimming Robot using Ionic Polymer Artificial Muscles. in Intelligent Robots and Systems, 2006 IEEE/RSJ International Conference on. 2006. 76. Kosa, G., M. Shoham, and M. Zaaroor. Analysis of a Swimming Micro Robot. in Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on. 2006. 77. Carta, R., et al., A multi-coil inductive powering system for an endoscopic capsule with vibratory actuation. Sensors and Actuators A: Physical, 2011. 172(1): p. 253-258. 78. Hong, D.W., M. Ingram, and D. Lahr, Whole Skin Locomotion Inspired by Amoeboid Motility Mechanisms. Journal of Mechanisms and Robotics, 2009. 1(1): p. 011015. 79. Sliker, L.J., et al., Surgical evaluation of a novel tethered robotic capsule endoscope using micro-patterned treads. Surg Endosc, 2012. 26(10): p. 2862-9. 80. Young-Sik, K., et al. Design and motion planning of a two-moduled indoor pipeline inspection robot. in Robotics and Automation, 2008. ICRA 2008. IEEE International Conference on. 2008. 81. Jungwan, P., K. Taehyun, and Y. Hyunseok. Development of an actively adaptable in-pipe robot. in Mechatronics, 2009. ICM 2009. IEEE International Conference on. 2009. 82. Liu, Q., T. Ren, and Y. Chen, Characteristic analysis of a novel in-pipe driving robot. Mechatronics, 2013. 23(4): p. 419-428. 83. Lambrecht, B.G.A., A.D. Horchler, and R.D. Quinn. A Small, Insect-Inspired Robot that Runs and Jumps. in Robotics and Automation, 2005. ICRA 2005. Proceedings of the 2005 IEEE International Conference on. 2005. 84. Kim, Y.T. and D.E. Kim, Novel Propelling Mechanisms Based on Frictional Interaction for Endoscope Robot. Tribology Transactions, 2010. 53(2): p. 203-211. 195 85. Crespi, A. and A.J. Ijspeert, Online Optimization of Swimming and Crawling in an Amphibious Snake Robot. Robotics, IEEE Transactions on, 2008. 24(1): p. 75-87. 86. Dario, P., et al., Modeling and Experimental Validation of the Locomotion of Endoscopic Robots in the Colon. The International Journal of Robotics Research, 2004. 23(4): p. 549-556. 87. Phee, L., et al., Analysis and development of locomotion devices for the gastrointestinal tract. Biomedical Engineering, IEEE Transactions on, 2002. 49(6): p. 613-616. 88. Kundong, W., et al. Squirm robot with full bellow skin for colonoscopy. in Robotics and Biomimetics (ROBIO), 2010 IEEE International Conference on. 2010. 89. Karagozler, M.E., et al. Miniature Endoscopic Capsule Robot using Biomimetic Micro-Patterned Adhesives. in Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on. 2006. 90. Stefanini, C., Modeling and Experiments on a Legged Microrobot Locomoting in a Tubular, Compliant and Slippery Environment. The International Journal of Robotics Research, 2006. 25(5-6): p. 551-560. 91. Weida, L., et al. A Novel Locomotion Principle for Endoscopic Robot. in Mechatronics and Automation, Proceedings of the 2006 IEEE International Conference on. 2006. 92. Quirini, M., et al. Design of a Pill-Sized 12-legged Endoscopic Capsule Robot. in Robotics and Automation, 2007 IEEE International Conference on. 2007. 93. Kim, H.M., et al., Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos). Gastrointest Endosc, 2010. 72(2): p. 381-7. 94. Heijnsdijk, E.A., et al., Inter- and intraindividual variabilities of perforation forces of human and pig bowel tissue. Surg Endosc, 2003. 17(12): p. 1923-6. 95. Moshkowitz, M., et al., A novel device for rapid cleaning of poorly prepared colons. Endoscopy, 2010. 42(10): p. 834-6. 96. Lee, S.H., et al., An optimal micropatterned end-effecter for enhancing frictional force on large intestinal surface. ACS Appl Mater Interfaces, 2010. 2(5): p. 1308-16. 97. Paparo, F., et al., Computed tomography of the bowel: a prospective comparison study between four techniques. Eur J Radiol, 2013. 82(1): p. e1-e10. 98. Gao, P., et al., Microgroove cushion of robotic endoscope for active locomotion in the gastrointestinal tract. Int J Med Robot, 2012. 8(4): p. 398-406. 99. Buselli, E., et al., Evaluation of friction enhancement through soft polymer micro-patterns in active capsule endoscopy. Measurement Science and Technology, 2010. 21(10): p. 105802. 100. Dodou, D., P. Breedveld, and P.A. Wieringa, Mucoadhesives in the gastrointestinal tract: revisiting the literature for novel applications. Eur J Pharm Biopharm, 2005. 60(1): p. 1-16. 101. Smart, J.D., The basics and underlying mechanisms of mucoadhesion. Adv Drug Deliv Rev, 2005. 57(11): p. 1556-68. 102. Dodou, D., et al., Mucoadhesive films inside the colonic tube: performance in a three-dimensional world. J R Soc Interface, 2008. 5(28): p. 1353-62. 103. Dodou, D., P. Breedveld, and P.A. Wieringa, Stick, unstick, restick sticky films in the colon. Minim Invasive Ther Allied Technol, 2006. 15(5): p. 286-95. 104. Dodou, D., P. Breedveld, and P.A. Wieringa, Friction manipulation for intestinal locomotion. Minim Invasive Ther Allied Technol, 2005. 14(3): p. 188-97. 105. Tramacere, F., et al., The morphology and adhesion mechanism of Octopus vulgaris suckers. PLoS One, 2013. 8(6): p. e65074. 106. Ge, D., et al., Quantitative study on the attachment and detachment of a passive suction cup. Vacuum, 2015. 116: p. 13-20. 196 107. Patronik, N.A., et al. Improved Traction for a Mobile Robot Traveling on the Heart. in 2006 International Conference of the IEEE Engineering in Medicine and Biology Society. 2006. 108. Lyle, A.B., J.T. Luftig, and M.E. Rentschler, A tribological investigation of the small bowel lumen surface. Tribology International, 2013. 62: p. 171-176. 109. Egorov, V.I., et al., Mechanical properties of the human gastrointestinal tract. Journal of Biomechanics, 2002. 35(10): p. 1417-1425. 110. Christensen, M.B., K. Oberg, and J.C. Wolchok, Tensile properties of the rectal and sigmoid colon: a comparative analysis of human and porcine tissue. Springerplus, 2015. 4: p. 142. 111. Higa, M., et al., Passive mechanical properties of large intestine under in vivo and in vitro compression. Med Eng Phys, 2007. 29(8): p. 840-4. 112. Shamsuddin, A.M., P.C. Phelps, and B.F. Trump, Human Large Intestinal Epithelium - Light-Microscopy, Histochemistry, and Ultrastructure. Human Pathology, 1982. 13(9): p. 790-803. 113. Cone, R.A., Barrier properties of mucus. Adv Drug Deliv Rev, 2009. 61(2): p. 75-85. 114. Gustafsson, J.K., et al., An ex vivo method for studying mucus formation, properties, and thickness in human colonic biopsies and mouse small and large intestinal explants. Am J Physiol Gastrointest Liver Physiol, 2012. 302(4): p. G430-8. 115. Lai, S.K., et al., Micro- and macrorheology of mucus. Adv Drug Deliv Rev, 2009. 61(2): p. 86-100. 116. Finkelstone, L., E. Wolf, and M.W. Stein, Etiology of small bowel thickening on computed tomography. Canadian Journal of Gastroenterology, 2012. 26(12): p. 897-901. 117. Kim, D.E. and Y.T. Kim, Biotribological investigation of a multi-tube foot for traction generation in a medical microrobot. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2009. 223(6): p. 677-686. 118. Atuma, C., et al., The adherent gastrointestinal mucus gel layer: thickness and physical state in vivo. American Journal of Physiology-Gastrointestinal and Liver Physiology, 2001. 280(5): p. G922-G929. 119. Kim, J.S., et al., Experimental investigation of frictional and viscoelastic properties of intestine for microendoscope application. Tribology Letters, 2006. 22(2): p. 143-149. 120. Lyle, A.B., et al., Preliminary Friction Force Measurements on Small Bowel Lumen When Eliminating Sled Edge Effects. Tribology Letters, 2013. 51(3): p. 377-383. 121. Zhang, C., et al., Modeling of Velocity-dependent Frictional Resistance of a Capsule Robot Inside an Intestine. Tribology Letters, 2012. 47(2): p. 295-301. 122. Accoto, D., et al. Measurements of the frictional properties of the gastrointestinal tract. in World Tribology Congress. 2001. 123. Chen, H., et al., Bioinspired Surface for Surgical Graspers Based on the Strong Wet Friction of Tree Frog Toe Pads. ACS Appl Mater Interfaces, 2015. 7(25): p. 13987-95. 124. Barnes, W.J., et al., Elastic modulus of tree frog adhesive toe pads. J Comp Physiol A Neuroethol Sens Neural Behav Physiol, 2011. 197(10): p. 969-78. 125. Varenberg, M. and S.N. Gorb, Hexagonal Surface Micropattern for Dry and Wet Friction. Advanced Materials, 2009. 21(4): p. 483-486. 126. Drotlef, D.M., et al., Morphological studies of the toe pads of the rock frog, Staurois parvus (family: Ranidae) and their relevance to the development of new biomimetically inspired reversible adhesives. Interface Focus, 2015. 5(1): p. 20140036. 127. Drotlef, D.-M., et al., Insights into the Adhesive Mechanisms of Tree Frogs using Artificial Mimics. Advanced Functional Materials, 2013. 23(9): p. 1137-1146. 128. Iturri, J., et al., Torrent Frog-Inspired Adhesives: Attachment to Flooded Surfaces. Advanced Functional Materials, 2015. 25(10): p. 1499-1505. 197 129. Murarash, B., Y. Itovich, and M. Varenberg, Tuning elastomer friction by hexagonal surface patterning. Soft Matter, 2011. 7(12): p. 5553. 130. Persson, B.N.J., Wet adhesion with application to tree frog adhesive toe pads and tires. Journal of Physics: Condensed Matter, 2007. 19(37): p. 376110. 131. Cho, J.R., et al., Numerical investigation of hydroplaning characteristics of three-dimensional patterned tire. European Journal of Mechanics - A/Solids, 2006. 25(6): p. 914-926. 132. Fwa, T., et al., Effectiveness of Tire-Tread Patterns in Reducing the Risk of Hydroplaning. Transportation Research Record: Journal of the Transportation Research Board, 2009. 2094: p. 91-102. 133. Persson, B.N.J., et al., Rubber friction on wet and dry road surfaces: The sealing effect. Physical Review B, 2005. 71(3). 134. Gupta, R. and J. Frechette, Measurement and scaling of hydrodynamic interactions in the presence of draining channels. Langmuir, 2012. 28(41): p. 14703-12. 135. Glass, P., E. Cheung, and M. Sitti, A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives. IEEE Trans Biomed Eng, 2008. 55(12): p. 2759-67. 136. Majidi, C., Soft robotics: a perspective—current trends and prospects for the future. Soft Robotics, 2014. 1(1): p. 5-11. 137. Yoshida, H., Y. Morita, and K. Ikeuchi, Biological lubrication of hydrated surface layer in small intestine. Tribol. Interface Eng. Ser.: Tribol. Res. Des. Eng. Syst, 2003. 41: p. 425-428. 138. Gong, J.P., Friction and lubrication of hydrogels—its richness and complexity. Soft Matter, 2006. 2(7): p. 544-552. 139. Kararli, T.T., Comparison of the gastrointestinal anatomy, physiology, and biochemistry of humans and commonly used laboratory animals. Biopharmaceutics & Drug Disposition, 1995. 16(5): p. 351-380. 140. Olakanmi, E.O., R.F. Cochrane, and K.W. Dalgarno, A review on selective laser sintering/melting (SLS/SLM) of aluminium alloy powders: Processing, microstructure, and properties. Progress in Materials Science, 2015. 74: p. 401-477. 141. Rentschler, M.E., S.M. Farritor, and K.D. Iagnemma, Mechanical Design of Robotic In Vivo Wheeled Mobility. Journal of Mechanical Design, 2007. 129(10): p. 1037. 142. Heijnsdijk, E.A.M., et al., Slip and damage properties of jaws of laparoscopic graspers. Surgical Endoscopy and Other Interventional Techniques, 2004. 18(6): p. 974-979. 143. Tur, J.M.M. and W. Garthwaite, Robotic devices for water main in‐pipe inspection: A survey. Journal of Field Robotics, 2010. 27(4): p. 491-508. 144. Majidi, C., Soft Robotics: A Perspective—Current Trends and Prospects for the Future. Soft Robotics, 2013. 1(P): p. 5-11. 145. Kim, S., C. Laschi, and B. Trimmer, Soft robotics: a bioinspired evolution in robotics. Trends Biotechnol, 2013. 31(5): p. 287-94. 146. Pfeifer, R., M. Lungarella, and F. Iida, The challenges ahead for bio-inspired 'soft' robotics. Communications of the ACM, 2012. 55(11): p. 76. 147. Lin, H.T., G.G. Leisk, and B. Trimmer, GoQBot: a caterpillar-inspired soft-bodied rolling robot. Bioinspir Biomim, 2011. 6(2): p. 026007. 148. Shepherd, R.F., et al., Multigait soft robot. Proceedings of the National Academy of Sciences, 2011. 108(51): p. 20400-20403. 149. Ying, S., et al., Variable Stiffness Structures Utilizing Fluidic Flexible Matrix Composites. Journal of Intelligent Material Systems and Structures, 2008. 20(4): p. 443-456. 198 150. Jiang, A., et al. Design of a variable stiffness flexible manipulator with composite granular jamming and membrane coupling. in Intelligent Robots and Systems (IROS), 2012 IEEE/RSJ International Conference on. 2012. 151. Yong-Jae, K., et al., A Novel Layer Jamming Mechanism With Tunable Stiffness Capability for Minimally Invasive Surgery. Robotics, IEEE Transactions on, 2013. 29(4): p. 1031-1042. 152. Wagner, N.J. and J.F. Brady, Shear thickening in colloidal dispersions. Physics Today, 2009. 62(10): p. 27-32. 153. Kuder, I.K., et al., Variable stiffness material and structural concepts for morphing applications. Progress in Aerospace Sciences, 2013. 63: p. 33-55. 154. Stokes, A.A., et al., A Hybrid Combining Hard and Soft Robots. Soft Robotics, 2014. 1(1): p. 70-74. 155. Laschi, C., et al., Soft Robot Arm Inspired by the Octopus. Advanced Robotics, 2012. 26(7): p. 709-727."],"dcterms:accessrights":["public"],"dc:title":["The Design and Development of a Mobile Colonoscopy Robot"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000199815936"]},"updated_at":"2026-11-18T22:19:48Z"}