{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:16667"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:16667","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Quantitative Dynamic Contrast Enhanced Magnetic Resonance Imaging for Evaluation of the Myocardium in Ischaemic Heart Disease","abstract":"Background: Use of contrast enhanced cardiac magnetic resonance imaging (MRI) for identification of focal pathology (perfusion deficit and scar) is widespread. Quantitative analysis of dynamic contrast enhanced (DCE) MRI data may allow objective assessment of focal and diffuse disease. However it is a complex process and not widely adopted outside the research domain. For accurate quantification temporal variation in relative contrast agent concentration in the myocardium and feeding blood supply must be measured. While MRI signal intensity can be used as a probe of contrast agent concentration its response is non-linear. Aims: In this thesis non-linearity correction methods for quantitative myocardial DCE-MRI are compared, the feasibility of a novel bookend T1 based correction is tested and the method is used in clinical studies to assess myocardial characteristics in health and ischaemic disease. Methods: Signal non-linearity correction methods were compared using simulation, phantom experiments and a volunteer study. Methods compared were independent sampling strategies (dual-bolus and dual-sequence), previously proposed model based correction (native T1 or proton density weighted image based) and bookend T1 based correction which is proposed as a method to account for imperfect magnetisation preparation. The feasibility of the bookend T1 method was tested and characteristics of heathy and diseased myocardium were assessed in clinical studies of ischaemia and infarction. Conclusions: Native T1 based correction has been found to be highly sensitive to imperfect magnetisation preparation, and is thus recommended against. Model based correction using proton density weighted images or bookend T1 data have been found to be more accurate and precise than dual-sampling methods. The clinical studies have demonstrated the feasibility of the bookend T1 based method and have yielded insights into myocardial characteristics in a range of conditions.","abstract_html":"Background: Use of contrast enhanced cardiac magnetic resonance imaging (MRI) for identification of focal pathology (perfusion deficit and scar) is widespread. Quantitative analysis of dynamic contrast enhanced (DCE) MRI data may allow objective assessment of focal and diffuse disease. However it is a complex process and not widely adopted outside the research domain. For accurate quantification temporal variation in relative contrast agent concentration in the myocardium and feeding blood supply must be measured. While MRI signal intensity can be used as a probe of contrast agent concentration its response is non-linear. Aims: In this thesis non-linearity correction methods for quantitative myocardial DCE-MRI are compared, the feasibility of a novel bookend T1 based correction is tested and the method is used in clinical studies to assess myocardial characteristics in health and ischaemic disease. Methods: Signal non-linearity correction methods were compared using simulation, phantom experiments and a volunteer study. Methods compared were independent sampling strategies (dual-bolus and dual-sequence), previously proposed model based correction (native T1 or proton density weighted image based) and bookend T1 based correction which is proposed as a method to account for imperfect magnetisation preparation. The feasibility of the bookend T1 method was tested and characteristics of heathy and diseased myocardium were assessed in clinical studies of ischaemia and infarction. Conclusions: Native T1 based correction has been found to be highly sensitive to imperfect magnetisation preparation, and is thus recommended against. Model based correction using proton density weighted images or bookend T1 data have been found to be more accurate and precise than dual-sampling methods. The clinical studies have demonstrated the feasibility of the bookend T1 based method and have yielded insights into myocardial characteristics in a range of conditions.","abstract_has_math":false,"creators":["Broadbent, David Andrew"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Buckley, David L","Plein, Sven"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-10","date_published":"2015-10","updated_at":"2026-11-18T22:20:20Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.707029"],"render_values":[{"text":"uk.bl.ethos.707029","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["DRF-2012-05-155"],"render_values":[{"text":"DRF-2012-05-155","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000258924762"],"render_values":[{"text":"0000-0002-5892-4762","href":"https://orcid.org/0000-0002-5892-4762","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/16667/1/Broadbent_DA_Medicine_PhD_2015.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A16667","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Buckley, David L","Plein, Sven"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["National Institute for Health Research"]},{"key":"dc:creator","label":"Author","values":["Broadbent, David Andrew"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000258924762"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-10"]},{"key":"dc:date.issued","label":"Date","values":["2015-10"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Academic Unit of Medical Physics (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/16667/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. Broadbent D, Biglands J, Larghat A, Sourbron S, Radjenovic A, Greenwood J, Plein S, Buckley D: Myocardial blood flow at rest and stress measured with dynamic contrast-enhanced MRI: Comparison of a distributed parameter model with a fermi function model. Magn Reson Med 2013, 70:1591-1597. 2. Pennell D, Sechtem U, Higgins C, Manning W, Pohost G, Rademakers F, van Rossum A, Shaw L, Yucel K: Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report. Eur Heart J 2004, 25:1940-1965. 3. Wilke N, Jerosch-Herold M, Stillman AE, Kroll K, Tsekos N, Merkle H, Parrish T, Hu X, Wang Y, Bassingthwaighte J: Concepts of myocardial perfusion imaging in magnetic resonance imaging. Magn Reson Q 1994, 10:249-286. 4. Wilke N, Kroll K, Merkle H, Wang Y, Ishibashi Y, Xu Y, Zhang J, Jerosch-Herold M, Muhler A, Stillman A, et al: Regional myocardial blood volume and flow: First-pass MR imaging with polylysine-Gd-DTPA. Journal of magnetic resonance imaging : JMRI 1995, 5:227-237. 5. Kim R, Chen E-L, Lima Jo, Judd R: Myocardial Gd-DTPA Kinetics Determine MRI Contrast Enhancement and Reflect the Extent and Severity of Myocardial Injury After Acute Reperfused Infarction. Circulation 1996, 94:3318-3326. 6. Kim RJ, Fieno DS, Parrish TB, Harris K, Chen EL, Simonetti O, Bundy J, Finn JP, Klocke FJ, Judd RM: Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function. Circulation 1999, 100:1992-2002. 7. Messroghli D, Radjenovic A, Kozerke S, Higgins D, Sivananthan M, Ridgway J: Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magn Reson Med 2004, 52:141-146. 8. McDiarmid A, Swoboda P, Erhayiem B, Ripley D, Kidambi A, Broadbent D, Higgins D, Greenwood J, Plein S: Single bolus versus split dose gadolinium administration in extra-cellular volume calculation at 3 Tesla. Journal of Cardiovascular Magnetic Resonance 2015, 17:6. 9. McDiarmid A, Higgins D, Broadbent D, Ripley D, Swoboda P, Kidambi A, Erhayiem B, Musa T, Dobson L, Garg P, et al: Split dose versus single bolus gadolinium administration in ecv calculation at 3 Tesla CMR. Journal of Cardiovascular Magnetic Resonance 2015, 17:P257. 10. McDiarmid A, Broadbent D, Higgins D, Swoboda P, Kidambi A, Ripley D, Erhayiem B, Al Musa T, Dobson L, Greenwood J, Plein S: The effect of changes to MOLLI scheme on T1 mapping and extra cellular volume calculation in healthy volunteers with 3 tesla cardiovascular magnetic resonance imaging. Quantitative imaging in medicine and surgery 2015, 5:503-510. 11. McDiarmid A, Swoboda P, Erhayiem B, Lancaster R, Lyall G, Broadbent D, Dobson L, Musa T, Ripley D, Garg P, et al: Athletic Cardiac Adaptation in Males Is a Consequence of Elevated Myocyte Mass. Circulation: Cardiovascular Imaging 2016, 9:e003579. 12. Biglands J, Ripley D, Broadbent D, Higgins D, Swoboda P, McDiarmid A, Garg P, Plein S, Buckley D: A comparison of dual-bolus and dual-sequence quantitative myocardial perfusion techniques. Journal of Cardiovascular Magnetic Resonance 2015, 17:P50. 13. Broadbent D, Higgins D, Ferreira V, Liu A, Marini C, Kramer C, Plein S, Neubauer S, Piechnik S: Pilot Data on Inter-Centre and Inter-Vendor Comparison of MOLLI and ShMOLLI T1 Mapping Variants at 3T. In Joint Annual Meeting ISMRM-ESMRMB; Milan, Italy. 2014: 2449. 14. Dabir D, Child N, Kalra A, Rogers T, Gebker R, Jabbour A, Plein S, Yu C, Otton J, Kidambi A, et al: Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study. Journal of Cardiovascular Magnetic Resonance 2014, 16:69. 15. Kidambi A, Biglands J, Higgins D, Ripley D, Zaman A, Broadbent D, McDiarmid A, Swoboda P, Musa T, Erhayiem B, et al: Susceptibility-weighted cardiovascular magnetic resonance in comparison to T2 and T2 star imaging for detection of intramyocardial hemorrhage following acute myocardial infarction at 3 Tesla. Journal of Cardiovascular Magnetic Resonance 2014, 16:86. 16. Kidambi A, Biglands J, Higgins D, Ripley D, Zaman A, Broadbent D, McDiarmid A, Swoboda P, Musa T, Erhayiem B, et al: Clinical validation of susceptibility-weighted cardiovascular magnetic resonance in comparison to T2 and T2* imaging for detection of intramyocardial hemorrhage following acute myocardial infarction. Journal of Cardiovascular Magnetic Resonance 2015, 17:P117. 17. Kidambi A, Motwani M, Uddin A, Ripley D, McDiarmid A, Swoboda P, Broadbent D, Musa T, Erhayiem B, Leader J, et al: Myocardial extracellular volume estimation by CMR predicts functional recovery following acute myocardial infarction. Journal of Cardiovascular Magnetic Resonance 2015, 17:Q63. 18. Kidambi A, Motwani M, Uddin A, Ripley D, McDiarmid A, Swoboda P, Broadbent D, Musa T, Erhayiem B, Leader J, et al: 125 Myocardial Extracellular Volume Estimation by Cardiovascular Magnetic Resonance Predicts Functional Recovery Following Acute Myocardial Infarction. Heart 2015, 101:A72-A72. 19. Broadbent D, Kidambi A, Biglands J: Cardiovascular Magnetic Resonance Physics for Clinicians. In CMR Pocket Guides (Herzog B, Greenwood J, Plein S eds.): EACVI (CMR Section); 2015. 20. Greenbaum RA, Ho SY, Gibson DG, Becker AE, Anderson RH: Left ventricular fibre architecture in man. Br Heart J 1981, 45:248-263. 21. Bassingthwaighte JB, Yipintsoi T, Harvey RB: Microvasculature of the dog left ventricular myocardium. Microvasc Res 1974, 7:229-249. 22. Roberts J, Wearn J: Quantitative changes in the capillary-muscle relationship in human hearts during normal growth and hypertrophy. Am Heart J 1941, 21:617-633. 23. Archie J: Myocardial oxygen transport. The interrelationship of coronary blood flow, oxygen diffusion and capillary recruitment. J Surg Res 1978, 25:200-210. 24. Botvinick E: Current Methods of Pharmacologic Stress Testing and the Potential Advantages of New Agents. J Nucl Med Technol 2009, 37:14-25. 25. Nesto R, Kowalchuk G: The ischemic cascade: Temporal sequence of hemodynamic, electrocardiographic and symptomatic expressions of ischemia. The American journal of cardiology 1987, 59:C23-C30. 26. Mewton N, Liu CY, Croisille P, Bluemke D, Lima J: Assessment of myocardial fibrosis with cardiovascular magnetic resonance. J Am Coll Cardiol 2011, 57:891-903. 27. Klug G, Mayr A, Schenk S, Esterhammer R, Schocke M, Nocker M, Jaschke W, Pachinger O, Metzler B: Prognostic value at 5 years of microvascular obstruction after acute myocardial infarction assessed by cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance 2012, 14. 28. Bekkers S, Yazdani S, Virmani R, Waltenberger J: Microvascular Obstruction. J Am Coll Cardiol 2010, 55:1649-1660. 29. Braunwald E, Kloner RA: Myocardial reperfusion: a double-edged sword? J Clin Invest 1985, 76:1713-1719. 30. de Waha S, Desch S, Eitel I, Fuernau G, Zachrau J, Leuschner A, Gutberlet M, Schuler G, Thiele H: Impact of early vs. late microvascular obstruction assessed by magnetic resonance imaging on long-term outcome after ST-elevation myocardial infarction: a comparison with traditional prognostic markers. Eur Heart J 2010, 31:2660-2668. 31. Choi KM, Kim RJ, Gubernikoff G, Vargas JD, Parker M, Judd RM: Transmural extent of acute myocardial infarction predicts long-term improvement in contractile function. Circulation 2001, 104:1101-1107. 32. Mahrholdt H, Wagner A, Parker M, Regenfus M, Fieno D, Bonow R, Kim R, Judd R: Relationship of contractile function to transmural extent of infarction in patients with chronic coronary artery disease. J Am Coll Cardiol 2003, 42:505-512. 33. Schuijf JD, Shaw LJ, Wijns W, Lamb HJ, Poldermans D, de Roos A, van der Wall EE, Bax JJ: Cardiac imaging in coronary artery disease: differing modalities. Heart (British Cardiac Society) 2005, 91:1110-1117. 34. Hashemi RH, Bradley WG, Lisanti CK: MRI: The Basics. Updated Third Edition edn: Lippincott Williams & Wilkins; 2012. 35. McRobbie DW, Moore EA, Graves MJ, Prince MR: MRI from Picture to Proton. 2nd edn: Cambridge University Press; 2007. 36. Ridgway J: Cardiovascular magnetic resonance physics for clinicians: part I. Journal of Cardiovascular Magnetic Resonance 2010, 12:71. 37. Garpebring A, Wirestam R, Östlund N, Karlsson M: Effects of inflow and radiofrequency spoiling on the arterial input function in dynamic contrast-enhanced MRI: A combined phantom and simulation study. Magn Reson Med 2011, 65:1670-1679. 38. Preibisch C, Deichmann R: Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles. Magn Reson Med 2009, 61:125-135. 39. Yarnykh V: Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady-state techniques. Magn Reson Med 2010, 63:1610-1626. 40. Donahue K, Burstein D, Manning W, Gray M: Studies of Gd-DTPA relaxivity and proton exchange rates in tissue. Magn Reson Med 1994, 32:66-76. 41. Donahue KM, Weisskoff RM, Burstein D: Water diffusion and exchange as they influence contrast enhancement. J Magn Reson Imaging 1997, 7:102-110. 42. Donahue KM, Weisskoff RM, Chesler DA, Kwong KK, Bogdanov AA, Mandeville JB, Rosen BR: Improving MR quantification of regional blood volume with intravascular T1 contrast agents: accuracy, precision, and water exchange. Magn Reson Med 1996, 36:858-867. 43. Coelho-Filho O, Mongeon F-P, Mitchell R, Moreno H, Nadruz W, Kwong R, Jerosch-Herold M: Role of transcytolemmal water-exchange in magnetic resonance measurements of diffuse myocardial fibrosis in hypertensive heart disease. Circulation Cardiovascular imaging 2013, 6:134-141. 44. Larsson H, Fritz-Hansen T, Rostrup E, Søndergaard L, Ring P, Henriksen O: Myocardial perfusion modeling using MRI. Magn Reson Med 1996, 35:716-726. 45. Kershaw L: Measuring microvascular physiology using quantitative magnetic resonance imaging. University of Manchester, School of Medicine; 2008. 46. Weinmann HJ, Brasch RC, Press WR, Wesbey GE: Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent. Am J Roentgenol 1984, 142:619-624. 47. Koenig S, Spiller M, Brown R, Wolf G: Relaxation of water protons in the intra- and extracellular regions of blood containing Gd(DTPA). Magn Reson Med 1986, 3:791-795. 48. Boudreau RJ, Burbidge S, Sirr S, Loken MK: Comparison of the biodistribution of manganese-54 DTPA and gadolinium-153 DTPA in dogs. Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1987, 28:349-353. 49. Prato F, Wisenberg G, Marshall T, Uksik P, Zabel P: Comparison of the Biodistribution of Gadolinium-153 DTPA and Technetium-99m DTPA in Rats. J Nucl Med 1988, 29:1683-1687. 50. Coelho-Filho O, Shah R, Mitchell R, Neilan T, Moreno H, Simonson B, Kwong R, Rosenzweig A, Das S, Jerosch-Herold M: Quantification of Cardiomyocyte Hypertrophy by Cardiac Magnetic Resonance. Circulation 2013, 128:1225-1233. 51. Sourbron SP, Buckley DL: Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability. Phys Med Biol 2012, 57:R1. 52. Parker G, Roberts C, Macdonald A, Buonaccorsi G, Cheung S, Buckley D, Jackson A, Watson Y, Davies K, Jayson G: Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med 2006, 56:993-1000. 53. Gerber B, Raman S, Nayak K, Epstein F, Ferreira P, Axel L, Kraitchman D: Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art. Journal of Cardiovascular Magnetic Resonance 2008, 10:18. 54. Jerosch-Herold M: Quantification of myocardial perfusion by cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance 2010, 12:57. 55. Garpebring A, Ostlund N, Karlsson M: A novel estimation method for physiological parameters in dynamic contrast-enhanced MRI: application of a distributed parameter model using Fourier-domain calculations. IEEE Trans Med Imaging 2009, 28:1375-1383. 56. Jerosch-Herold M, Wilke N, Stillman AE: Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution. Med Phys 1998, 25:73-84. 57. Kershaw L, Buckley D: Precision in measurements of perfusion and microvascular permeability with T1-weighted dynamic contrast-enhanced MRI. Magn Reson Med 2006, 56:986-992. 58. Cheong LH, Koh TS, Hou Z: An automatic approach for estimating bolus arrival time in dynamic contrast MRI using piecewise continuous regression models. Phys Med Biol 2003, 48:N83. 59. Natsume T, Ishida M, Kitagawa K, Nagata M, Sakuma H, Ichihara T: Theoretical considerations in measurement of time discrepancies between input and myocardial time–signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI. Magn Reson Imaging 2015, 33:1059-1065. 60. Al Jaroudi W, Iskandrian A: Regadenoson: A New Myocardial Stress Agent. J Am Coll Cardiol 2009, 54:1123-1130. 61. Messroghli D, Bainbridge G, Alfakih K, Jones T, Plein S, Ridgway J, Sivananthan M: Assessment of regional left ventricular function: accuracy and reproducibility of positioning standard short-axis sections in cardiac MR imaging. Radiology 2005, 235:229-236. 62. Kramer C, Barkhausen J, Flamm S, Kim R, Nagel E: Standardized cardiovascular magnetic resonance (CMR) protocols 2013 update. Journal of Cardiovascular Magnetic Resonance 2013, 15:91. 63. Motwani M, Maredia N, Fairbairn T, Kozerke S, Greenwood J, Plein S: Assessment of ischaemic burden in angiographic three-vessel coronary artery disease with high-resolution myocardial perfusion cardiovascular magnetic resonance imaging. European heart journal cardiovascular Imaging 2014, 15:701-708. 64. Johnston D, Liu P, Lauffer R, Newell J, Wedeen V, Rosen B, Brady T, Okada R: Use of Gadolinium-DTPA as a Myocardial Perfusion Agent: Potential Applications and Limitations for Magnetic Resonance Imaging. J Nucl Med 1987, 28:871-877. 65. de Roos A, Doornbos J, van der Wall EE, van Voorthuisen AE: MR imaging of acute myocardial infarction: value of Gd-DTPA. Am J Roentgenol 1988, 150:531-534. 66. Biglands J, Radjenovic A, Ridgway J: Cardiovascular magnetic resonance physics for clinicians: part II. Journal of Cardiovascular Magnetic Resonance 2012, 14:66. 67. Flett A, Hayward M, Ashworth M, Hansen M, Taylor A, Elliott P, McGregor C, Moon J: Equilibrium contrast cardiovascular magnetic resonance for the measurement of diffuse myocardial fibrosis: preliminary validation in humans. Circulation 2010, 122:138-144. 68. Fedele F, Montesano T, Ferro-Luzzi M, Di Cesare E, Di Renzi P, Scopinaro F, Agati L, Penco M, Serri F, Vitarelli A, Dagianti A: Identification of viable myocardium in patients with chronic coronary artery disease and left ventricular dysfunction: Role of magnetic resonance imaging. Am Heart J 1994, 128:484-489. 69. Finn P, Nael K, Deshpande V, Ratib O, Laub G: Cardiac MR imaging: state of the technology. Radiology 2006, 241:338-354. 70. Ordovás K, Reddy G, Higgins C: MRI in nonischemic acquired heart disease. Journal of magnetic resonance imaging : JMRI 2008, 27:1195-1213. 71. Ordovas K, Higgins C: Delayed contrast enhancement on MR images of myocardium: past, present, future. Radiology 2011, 261:358-374. 72. Karamitsos T, Francis J, Myerson S, Selvanayagam J, Neubauer S: The role of cardiovascular magnetic resonance imaging in heart failure. J Am Coll Cardiol 2009, 54:1407-1424. 73. Pennell D: Cardiovascular Magnetic Resonance. Circulation 2010, 121:692-705. 74. Jellis C, Martin J, Narula J, Marwick T: Assessment of nonischemic myocardial fibrosis. J Am Coll Cardiol 2010, 56:89-97. 75. Kellman P, Arai A: Cardiac imaging techniques for physicians: Late enhancement. Journal of magnetic resonance imaging : JMRI 2012, 36:529-542. 76. Kim R, Wu E, Rafael A, Chen E-L, Parker M, Simonetti O, Klocke F, Bonow R, Judd R: The Use of Contrast-Enhanced Magnetic Resonance Imaging to Identify Reversible Myocardial Dysfunction. N Engl J Med 2000, 343:1445-1453. 77. Peel S, Morton G, Chiribiri A, Schuster A, Nagel E, Botnar R: Dual Inversion-Recovery MR Imaging Sequence for Reduced Blood Signal on Late Gadolinium-enhanced Images of Myocardial Scar. Radiology 2012, 264:242-249. 78. Stirrat J, Joncas S, Salerno M, Drangova M, White J: Influence of phase correction of late gadolinium enhancement images on scar signal quantification in patients with ischemic and non-ischemic cardiomyopathy. Journal of Cardiovascular Magnetic Resonance 2015, 17:66. 79. Diesbourg L, Prato F, Wisenberg G, Drost D, Marshall T, Carroll E, O'Neill B: Quantification of myocardial blood flow and extracellular volumes using a bolus injection of Gd-DTPA: Kinetic modeling in canine ischemic disease. Magn Reson Med 1992, 23:239-253. 80. Kety S: The theory and applications of the exchange of inert gas at the lungs and tissues. Pharmacol Rev 1951, 3:1-41. 81. Kellman P, Arai A: Imaging sequences for first pass perfusion --a review. Journal of Cardiovascular Magnetic Resonance 2007, 9:525-537. 82. Larsson H, Stubgaard M, Søndergaard L, Henriksen O: In vivo quantification of the unidirectional influx constant for Gd-DTPA diffusion across the myocardial capillaries with MR imaging. Journal of magnetic resonance imaging : JMRI 1994, 4:433-440. 83. Tong C, Prato F, Wisenberg G, Lee T, Carroll E, Sandler D, Wills J: Techniques for the measurement of the local myocardial extraction efficiency for inert diffusible contrast agents such as gadopentate dimeglumine. Magn Reson Med 1993, 30:332-336. 84. Tong C, Prato F, Wisenberg G, Lee T, Carroll E, Sandler D, Wills J, Drost D: Measurement of the extraction efficiency and distribution volume for Gd-DTPA in normal and diseased canine myocardium. Magn Reson Med 1993, 30:337-346. 85. Burstein D, Taratuta E, Manning W: Factors in myocardial “Perfusion” imaging with ultrafast MRI and Gd-DTPA administration. Magn Reson Med 1991, 20:299-305. 86. Atkinson DJ, Burstein D, Edelman RR: First-pass cardiac perfusion: evaluation with ultrafast MR imaging. Radiology 1990, 174:757-762. 87. Larsson HB, Fritz-Hansen T, Rostrup E, Søndergaard L, Ring P, Henriksen O: Myocardial perfusion modeling using MRI. Magn Reson Med 1996, 35:716-726. 88. Vallée JP, Sostman HD, MacFall JR, Wheeler T, Hedlund LW, Spritzer CE, Coleman RE: MRI quantitative myocardial perfusion with compartmental analysis: a rest and stress study. Magn Reson Med 1997, 38:981-989. 89. Tofts PS, Brix G, Buckley DL, Evelhoch JL, Henderson E, Knopp MV, Larsson HB, Lee TY, Mayr NA, Parker GJ, et al: Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. Journal of magnetic resonance imaging : JMRI 1999, 10:223-232. 90. Vallée JP, Lazeyras F, Kasuboski L, Chatelain P, Howarth N, Righetti A, Didier D: Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac function. Journal of magnetic resonance imaging : JMRI 1999, 9:197-203. 91. Nielsen G, Fritz-Hansen T, Dirks C, Jensen G, Larsson H: Evaluation of heart perfusion in patients with acute myocardial infarction using dynamic contrast-enhanced magnetic resonance imaging. Journal of magnetic resonance imaging : JMRI 2004, 20:403-410. 92. Flacke S, Fischer S, Lorenz C: Measurement of the Gadopentetate Dimeglumine Partition Coefficient in Human Myocardium in Vivo: Normal Distribution and Elevation in Acute and Chronic Infarction. Radiology 2001, 218:703-710. 93. Pereira R, Prato F, Sykes J, Wisenberg G: Assessment of myocardial viability using MRI during a constant infusion of Gd-DTPA: Further studies at early and late periods of reperfusion. Magn Reson Med 1999, 42:60-68. 94. Pack N, Dibella E, Wilson B, McGann C: Quantitative myocardial distribution volume from dynamic contrast-enhanced MRI. Magn Reson Imaging 2008, 26:532-542. 95. Jerosch-Herold M, Swingen C, Seethamraju RT: Myocardial blood flow quantification with MRI by model-independent deconvolution. Med Phys 2002, 29:886-897. 96. Jerosch-Herold M, Hershberger RE, Broberg C: Estimation of the Myocardial Extracellular Volume Fraction from Dynamic Contrast-Enhancement Measurements and Comparison with Partition Coefficient Measurements. In Proceedings of the 17th Scientific Meeting & Exhibition ISMRM; Hawaii, USA. 2009: 1743. 97. Pack N, DiBella E: Comparison of myocardial perfusion estimates from dynamic contrast-enhanced magnetic resonance imaging with four quantitative analysis methods. Magn Reson Med 2010, 64:125-137. 98. Hsu B: PET tracers and techniques for measuring myocardial blood flow in patients with coronary artery disease. Journal of biomedical research 2013, 27:452-459. 99. Handayani A, Triadyaksa P, Dijkstra H, Pelgrim GJ, van Ooijen P, Prakken N, Schoepf J, Oudkerk M, Vliegenthart R, Sijens P: Intermodel agreement of myocardial blood flow estimation from stress-rest myocardial perfusion magnetic resonance imaging in patients with coronary artery disease. Invest Radiol 2015, 50:275-282. 100. Biglands J, Magee D, Sourbron S, Plein S, Greenwood J, Radjenovic A: Comparison of the Diagnostic Performance of Four Quantitative Myocardial Perfusion Estimation Methods Used in Cardiac MR Imaging: CE-MARC Substudy. Radiology 2014. 101. Biglands J, Magee D, Boyle R, Larghat A, Plein S, Radjenović A: Evaluation of the effect of myocardial segmentation errors on myocardial blood flow estimates from DCE-MRI. Phys Med Biol 2011, 56:2423-2443. 102. Cernicanu A, Axel L: Theory-based signal calibration with single-point T1 measurements for first-pass quantitative perfusion MRI studies. Acad Radiol 2006, 13:686-693. 103. Christian T, Rettmann D, Aletras A, Liao S, Taylor J, Balaban R, Arai A: Absolute Myocardial Perfusion in Canines Measured by Using Dual-Bolus First-Pass MR Imaging. Radiology 2004, 232:677-684. 104. Hsu L-Y, Rhoads K, Holly J, Kellman P, Aletras A, Arai A: Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans. J Magn Reson Imaging 2006, 23:315-322. 105. Köstler H, Ritter C, Lipp M, Beer M, Hahn D, Sandstede J: Prebolus quantitative MR heart perfusion imaging. Magn Reson Med 2004, 52:296-299. 106. Groothuis J, Kremers F, Beek A, Brinckman S, Tuinenburg A, Jerosch-Herold M, van Rossum A, Hofman M: Comparison of dual to single contrast bolus magnetic resonance myocardial perfusion imaging for detection of significant coronary artery disease. Journal of magnetic resonance imaging : JMRI 2010, 32:88-93. 107. Hsu L-Y, Kellman P, Arai A: Nonlinear myocardial signal intensity correction improves quantification of contrast-enhanced first-pass MR perfusion in humans. J Magn Reson Imaging 2008, 27:793-801. 108. Gatehouse P, Elkington A, Ablitt N, Yang G-Z, Pennell D, Firmin D: Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance. J Magn Reson Imaging 2004, 20:39-45. 109. Sánchez-González J, Fernandez-Jiménez R, Nothnagel N, López-Martín G, Fuster V, Ibañez B: Optimization of dual-saturation single bolus acquisition for quantitative cardiac perfusion and myocardial blood flow maps. Journal of Cardiovascular Magnetic Resonance 2015, 17:21. 110. Kim D, Axel L: Multislice, dual-imaging sequence for increasing the dynamic range of the contrast-enhanced blood signal and CNR of myocardial enhancement at 3T. Journal of magnetic resonance imaging : JMRI 2006, 23:81-86. 111. Kholmovski E, DiBella E: Perfusion MRI with radial acquisition for arterial input function assessment. Magn Reson Med 2007, 57:821-827. 112. Chen D, Sharif B, Dharmakumar R, Thomson L, Bairey Merz N, Berman D, Li D: Improved quantification of myocardial blood flow using highly constrained back projection reconstruction. Magn Reson Med 2014, 72:749-755. 113. Ge L, Kino A, Griswold M, Mistretta C, Carr J, Li D: Myocardial perfusion MRI with sliding-window conjugate-gradient HYPR. Magn Reson Med 2009, 62:835-839. 114. Arheden H, Saeed M, Higgins C, Gao D-W, Bremerich J, Wyttenbach R, Dae M, Wendland M: Measurement of the Distribution Volume of Gadopentetate Dimeglumine at Echo-planar MR Imaging to Quantify Myocardial Infarction: Comparison with 99mTc-DTPA Autoradiography in Rats1. Radiology 1999, 211:698-708. 115. Thornhill R, Prato F, Wisenberg G, White J, Nowell J, Sauer A: Feasibility of the single-bolus strategy for measuring the partition coefficient of Gd-DTPA in patients with myocardial infarction: independence of image delay time and maturity of scar. Magn Reson Med 2006, 55:780-789. 116. Schelbert E, Testa S, Meier C, Ceyrolles W, Levenson J, Blair A, Kellman P, Jones B, Ludwig D, Schwartzman D, et al: Myocardial extravascular extracellular volume fraction measurement by gadolinium cardiovascular magnetic resonance in humans: slow infusion versus bolus. Journal of Cardiovascular Magnetic Resonance 2011, 13:16. 117. Salerno M, Janardhanan R, Jiji R, Brooks J, Adenaw N, Mehta B, Yang Y, Antkowiak P, Kramer C, Epstein F: Comparison of methods for determining the partition coefficient of gadolinium in the myocardium using T1 mapping. Journal of magnetic resonance imaging : JMRI 2012, 38:217-224. 118. Kawel N, Nacif M, Zavodni A, Jones J, Liu S, Sibley C, Bluemke D: T1 mapping of the myocardium: intra-individual assessment of post-contrast T1 time evolution and extracellular volume fraction at 3T for Gd-DTPA and Gd-BOPTA. Journal of Cardiovascular Magnetic Resonance 2012, 14:26. 119. Milanesi M, Barison A, Positano V, Masci P, De Marchi D, Marinelli L, Hardy C, Foo T, Landini L, Lombardi M: Modified cine inversion recovery pulse sequence for the quantification of myocardial T1 and gadolinium partition coefficient. Journal of magnetic resonance imaging : JMRI 2013, 37:109-118. 120. Kawel N, Nacif M, Zavodni A, Jones J, Liu S, Sibley C, Bluemke D: T1 mapping of the myocardium: Intra-individual assessment of the effect of field strength, cardiac cycle and variation by myocardial region. Journal of Cardiovascular Magnetic Resonance 2012, 14:27. 121. Judd R, Atalay M, Rottman G, Zerhouni E: Effects of Myocardial Water Exchange on T1 Enhancement during Bolus Administration of MR Contrast Agents. Magn Reson Med 1995, 33:215-223. 122. Judd R, Reeder S, May-Newman K: Effects of water exchange on the measurement of myocardial perfusion using paramagnetic contrast agents. Magn Reson Med 1999, 41:334-342. 123. Wacker CM, Bock M, Hartlep AW, Beck G, van Kaick G, Ertl G, Bauer WR, Schad LR: Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T*2 and T1 measurements. Magn Reson Med 1999, 41:686-695. 124. Higgins D, Ridgway J, Radjenovic A, Sivananthan M, Smith M: T1 measurement using a short acquisition period for quantitative cardiac applications. Med Phys 2005, 32:1738-1746. 125. Look DC, Locker DR: Time Saving in Measurement of NMR and EPR Relaxation Times. Rev Sci Instrum 1970, 41:250-251. 126. Freeman AJ, Gowland PA, Mansfield P: Optimization of the ultrafast Look-Locker echo-planar imaging T1 mapping sequence. Magn Reson Imaging 1998, 16:765-772. 127. Deichmann R, Haase A: Quantification of T1 values by SNAPSHOT-FLASH NMR imaging. Journal of Magnetic Resonance (1969) 1992, 96:608-612. 128. Scheffler K, Hennig J: T1 quantification with inversion recovery TrueFISP. Magn Reson Med 2001, 45:720-723. 129. Messroghli D, Plein S, Higgins D, Walters K, Jones T, Ridgway J, Sivananthan M: Human myocardium: single-breath-hold MR T1 mapping with high spatial resolution--reproducibility study. Radiology 2006, 238:1004-1012. 130. Messroghli D, Greiser A, Fröhlich M, Dietz R, Schulz-Menger J: Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart. Journal of magnetic resonance imaging : JMRI 2007, 26:1081-1086. 131. Nacif M, Turkbey E, Gai N, Nazarian S, van der Geest R, Noureldin R, Sibley C, Ugander M, Liu S, Arai A, et al: Myocardial T1 mapping with MRI: Comparison of look-locker and MOLLI sequences. Journal of magnetic resonance imaging : JMRI 2011, 34:1367-1373. 132. Shao J, Rapacchi S, Kim-Lien N, Hu P: Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm: FLASH-MOLLI with BLESSPC T1 Mapping. J Magn Reson Imaging 2016, 43:414-425. 133. Marks B, Mitchell DG, Simelaro JP: Breath-holding in healthy and pulmonary-compromised populations: effects of hyperventilation and oxygen inspiration. Journal of magnetic resonance imaging : JMRI 1997, 7:595-597. 134. Lee J, Liu S, Nacif M, Ugander M, Han J, Kawel N, Sibley C, Kellman P, Arai A, Bluemke D: Myocardial T1 and extracellular volume fraction mapping at 3 tesla. Journal of Cardiovascular Magnetic Resonance 2011, 13:75. 135. Kellman P, Arai A, Xue H: T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision. Journal of Cardiovascular Magnetic Resonance 2013, 15:56. 136. Piechnik S, Ferreira V, Dall'Armellina E, Cochlin L, Greiser A, Neubauer S, Robson M: Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. Journal of cardiovascular magnetic resonance 2010, 12. 137. Piechnik S, Ferreira V, Lewandowski A, Ntusi N, Banerjee R, Holloway C, Hofman M, Sado D, Maestrini V, White S, et al: Normal variation of magnetic resonance T1 relaxation times in the human population at 1.5T using ShMOLLI. Journal of Cardiovascular Magnetic Resonance 2013, 15:13. 138. Fontana M, White S, Banypersad S, Sado D, Maestrini V, Flett A, Piechnik S, Neubauer S, Roberts N, Moon J: Comparison of T1 mapping techniques for ECV quantification. Histological validation and reproducibility of ShMOLLI versus multibreath-hold T1 quantification equilibrium contrast CMR. Journal of Cardiovascular Magnetic Resonance 2012, 14:88. 139. Song T, Stainsby J, Ho V, Hood M, Slavin G: Flexible cardiac T1 mapping using a modified look–locker acquisition with saturation recovery. Magn Reson Med 2012, 67:622-627. 140. Xue H, Greiser A, Zuehlsdorff S, Jolly M-P, Guehring J, Arai A, Kellman P: Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting. Magn Reson Med 2013, 69:1408-1420. 141. Chow K, Flewitt J, Green J, Pagano J, Friedrich M, Thompson R: Saturation recovery single-shot acquisition (SASHA) for myocardial T 1 mapping : SASHA for T 1 Mapping. Magn Reson Med 2014, 71:2082-2095. 142. Roujol S, Weingärtner S, Foppa M, Chow K, Kawaji K, Ngo L, Kellman P, Manning W, Thompson R, Nezafat R: Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE. Radiology 2014, 272:683-689. 143. Weingärtner S, Akçakaya M, Basha T, Kissinger K, Goddu B, Berg S, Manning W, Nezafat R: Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability: Improved Imaging of Scar/Fibrosis. Magn Reson Med 2014, 71:1024-1034. 144. Fitts M, Breton E, Kholmovski E, Dosdall D, Vijayakumar S, Hong K, Ranjan R, Marrouche N, Axel L, Kim D: Arrhythmia insensitive rapid cardiac T1 mapping pulse sequence. Magn Reson Med 2013, 70:1274-1282. 145. Stanisz G, Odrobina E, Pun J, Escaravage M, Graham S, Bronskill M, Henkelman M: T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 2005, 54:507-512. 146. Goldfarb J, Mathew S, Reichek N: Quantitative breath-hold monitoring of myocardial gadolinium enhancement using inversion recovery TrueFISP. Magn Reson Med 2005, 53:367-371. 147. Reiter U, Reiter G, Dorr K, Greiser A, Maderthaner R, Fuchsjäger M: Normal diastolic and systolic myocardial T1 values at 1.5-T MR imaging: correlations and blood normalization. Radiology 2014, 271:365-372. 148. Pereira R, Prato F, Wisenberg G, Sykes J: The determination of myocardial viability using Gd-DTPA in a canine model of acute myocardial ischemia and reperfusion. Magn Reson Med 1996, 36:684-693. 149. Pereira R, Prato F, Lekx K, Sykes J, Wisenberg G: Contrast-enhanced MRI for the assessment of myocardial viability after permanent coronary artery occlusion. Magn Reson Med 2000, 44:309-316. 150. Karamitsos T, Neubauer S: The prognostic value of late gadolinium enhancement CMR in nonischemic cardiomyopathies. Current Cardiology Reports 2013, 15. 151. Kuruvilla S, Adenaw N, Katwal A, Lipinski M, Kramer C, Salerno M: Late gadolinium enhancement on cardiac magnetic resonance predicts adverse cardiovascular outcomes in nonischemic cardiomyopathy: a systematic review and meta-analysis. Circulation Cardiovascular imaging 2014, 7:250-258. 152. Klein C, Nekolla S, Balbach T, Schnackenburg B, Nagel E, Fleck E, Schwaiger M: The influence of myocardial blood flow and volume of distribution on late Gd-DTPA kinetics in ischemic heart failure. Journal of magnetic resonance imaging : JMRI 2004, 20:588-594. 153. Selvanayagam J, Jerosch-Herold M, Porto I, Sheridan D, Cheng A, Petersen S, Searle N, Channon K, Banning A, Neubauer S: Resting Myocardial Blood Flow Is Impaired in Hibernating Myocardium. Circulation 2005, 112:3289-3296. 154. Hopp E, Bjørnerud A, Lunde K, Solheim S, Aakhus S, Arnesen H, Forfang K, Edvardsen T, Smith H: Perfusion MRI at rest in subacute and chronic myocardial infarct. Acta Radiol 2013, 54:401-411. 155. Jerosch-Herold M, Sheridan D, Kushner J, Nauman D, Burgess D, Dutton D, Alharethi R, Li D, Hershberger R: Cardiac magnetic resonance imaging of myocardial contrast uptake and blood flow in patients affected with idiopathic or familial dilated cardiomyopathy. American journal of physiology Heart and circulatory physiology 2008, 295. 156. Jacquier A, Kallifatidis A, Guibert N, Giorgi R, Falque C, Thuny F, Croisille P, Clarysse P, Maurel B, Flavian A, et al: Assessment of myocardial partition coefficient of gadolinium (λ) in dilated cardiomyopathy and its impact on segmental and global systolic function. Journal of magnetic resonance imaging : JMRI 2014, 40:1336-1341. 157. Treibel T, White S, Sado D, Hasleton J, Flett A, Herrey A, Hausenloy D, Moon J: Not all LGE is the same. Scar contrast volume of distribution is lower in HCM than in infarction. Journal of Cardiovascular Magnetic Resonance 2012, 14:O95. 158. Ellims A, Iles L, Ling L, Hare J, Kaye D, Taylor A: Diffuse myocardial fibrosis in hypertrophic cardiomyopathy can be identified by cardiovascular magnetic resonance, and is associated with left ventricular diastolic dysfunction. Journal of Cardiovascular Magnetic Resonance 2012, 14:76. 159. Ho C, Abbasi S, Neilan T, Shah R, Chen Y, Heydari B, Cirino A, Lakdawala N, Orav J, González A, et al: T1 Measurements Identify Extracellular Volume Expansion in Hypertrophic Cardiomyopathy Sarcomere Mutation Carriers With and Without Left Ventricular Hypertrophy. Circulation: Cardiovascular Imaging 2013, 6:415-422. 160. Brouwer W, Baars E, Germans T, de Boer K, Beek A, van der Velden J, van Rossum A, Hofman M: In-vivo T1 cardiovascular magnetic resonance study of diffuse myocardial fibrosis in hypertrophic cardiomyopathy. Journal of Cardiovascular Magnetic Resonance 2014, 16:28. 161. Broberg C, Chugh S, Conklin C, Sahn D, Jerosch-Herold M: Quantification of diffuse myocardial fibrosis and its association with myocardial dysfunction in congenital heart disease. Circulation Cardiovascular imaging 2010, 3:727-734. 162. Flett A, Sado D, Quarta G, Mirabel M, Pellerin D, Herrey A, Hausenloy D, Ariti C, Yap J, Kolvekar S, et al: Diffuse myocardial fibrosis in severe aortic stenosis: an equilibrium contrast cardiovascular magnetic resonance study. European Heart Journal – Cardiovascular Imaging 2012, 13:819-826. 163. Neilan T, Coelho-Filho O, Shah R, Feng J, Pena-Herrera D, Mandry D, Pierre-Mongeon F, Heydari B, Francis S, Moslehi J, et al: Myocardial Extracellular Volume by Cardiac Magnetic Resonance Imaging in Patients Treated With Anthracycline-Based Chemotherapy. The American journal of cardiology 2013, 111:717-722. 164. Tham E, Haykowsky M, Chow K, Spavor M, Kaneko S, Khoo N, Pagano J, Mackie A, Thompson R: Diffuse myocardial fibrosis by T1-mapping in children with subclinical anthracycline cardiotoxicity: relationship to exercise capacity, cumulative dose and remodeling. Journal of Cardiovascular Magnetic Resonance 2013, 15:48. 165. Rao A, Shah R, Garg R, Abbasi S, Neilan T, Perlstein T, Di Carli M, Jerosch-Herold M, Kwong R, Adler G: Aldosterone and myocardial extracellular matrix expansion in type 2 diabetes mellitus. The American journal of cardiology 2013, 112:73-78. 166. Khan JN, Wilmot EG, Leggate M, Singh A, Yates T, Nimmo M, Khunti K, Horsfield M, Biglands J, Clarysse P, et al: Subclinical diastolic dysfunction in young adults with Type 2 diabetes mellitus: a multiparametric contrast-enhanced cardiovascular magnetic resonance pilot study assessing potential mechanisms. European heart journal cardiovascular Imaging 2014. 167. Coelho-Filho O, Shah R, Neilan T, Mattos Souza J, Jose C, Carlos F, Lindemberg da Mota S-F, Martins de Oliveira P, Severino E, Jerosch-Herold M, Petrucci O: Characterization of both myocardial extracellular volume expansion and myocyte hypertrophy by CMR in heart transplantation recipients without active rejection: implications for early cardiac remodeling. Journal of Cardiovascular Magnetic Resonance 2015, 17:O75. 168. Parnham S, Gleadle J, Leong D, Grover S, Bradbrook C, Woodman R, De Pasquale C, Selvanayagam J: Myocardial perfusion is impaired in asymptomatic renal and liver transplant recipients: a cardiovascular magnetic resonance study. Journal of Cardiovascular Magnetic Resonance 2015, 17:56. 169. Banypersad S, Sado D, Flett A, Gibbs S, Pinney J, Maestrini V, Cox A, Fontana M, Whelan C, Wechalekar A, et al: Quantification of myocardial extracellular volume fraction in systemic AL amyloidosis: an equilibrium contrast cardiovascular magnetic resonance study. Circulation Cardiovascular imaging 2013, 6:34-39. 170. Thuny F, Lovric D, Schnell F, Bergerot C, Ernande L, Cottin V, Derumeaux G, Croisille P: Quantification of Myocardial Extracellular Volume Fraction with Cardiac MR Imaging for Early Detection of Left Ventricle Involvement in Systemic Sclerosis. Radiology 2014, 271:373-380. 171. Edwards N, Moody W, Yuan M, Hayer M, Ferro C, Townend J, Steeds R: Diffuse interstitial fibrosis and myocardial dysfunction in early chronic kidney disease. The American journal of cardiology 2015, 115:1311-1317. 172. Liu C-Y, Liu Y-C, Wu C, Armstrong A, Volpe G, van der Geest R, Liu Y, Hundley W, Gomes A, Liu S, et al: Evaluation of Age-Related Interstitial Myocardial Fibrosis With Cardiac Magnetic Resonance Contrast-Enhanced T1 Mapping. J Am Coll Cardiol 2013, 62:1280-1287. 173. Neilan T, Coelho-Filho O, Shah R, Abbasi S, Heydari B, Watanabe E, Chen Y, Mandry D, Pierre-Mongeon F, Blankstein R, et al: Myocardial extracellular volume fraction from T1 measurements in healthy volunteers and mice: relationship to aging and cardiac dimensions. JACC Cardiovascular imaging 2013, 6:672-683. 174. Miller C, Naish J, Bishop P, Coutts G, Clark D, Zhao S, Ray S, Yonan N, Williams S, Flett A, et al: Comprehensive Validation of Cardiovascular Magnetic Resonance Techniques for the Assessment of Myocardial Extracellular Volume. Circulation: Cardiovascular Imaging 2013. 175. Christophe de Meester de R, Bouzin C, Lazam S, Boulif J, Amzulescu M, Melchior J, Pasquet As, Vancraeynest D, Pouleur A-C, Vanoverschelde J-L, Gerber B: Histological Validation of measurement of diffuse interstitial myocardial fibrosis by myocardial extravascular volume fraction from Modified Look-Locker imaging (MOLLI) T1 mapping at 3T. Journal of Cardiovascular Magnetic Resonance 2015, 17:48. 176. Kellman P, Hansen M: T1-mapping in the heart: accuracy and precision. Journal of Cardiovascular Magnetic Resonance 2014, 16:2. 177. Broadbent DA, Biglands JD, Ripley DP, Higgins DM, Greenwood JP, Plein S, Buckley DL: Sensitivity of quantitative myocardial dynamic contrast-enhanced MRI to saturation pulse efficiency, noise and t1 measurement error: Comparison of nonlinearity correction methods. Magn Reson Med 2016, 75:1290-1300. 178. Broadbent D, Biglands J, Ripley D, Plein S, Buckley D: Comparison of non-linearity correction methods for quantitative myocardial perfusion MRI. Journal of Cardiovascular Magnetic Resonance 2015, 17:P45. 179. Utz W, Niendorf T, Wassmuth R, Messroghli D, Dietz R, Schulz-Menger J: Contrast-dose relation in first-pass myocardial MR perfusion imaging. J Magn Reson Imaging 2007, 25:1131-1135. 180. Kim D, Gonen O, Oesingmann N, Axel L: Comparison of the effectiveness of saturation pulses in the heart at 3T. Magn Reson Med 2008, 59:209-215. 181. Kim D, Oesingmann N, McGorty K: Hybrid adiabatic-rectangular pulse train for effective saturation of magnetization within the whole heart at 3 T. Magn Reson Med 2009, 62:1368-1378. 182. Kim D, Cernicanu A, Axel L: B0 and B1-insensitive uniform T1-weighting for quantitative, first-pass myocardial perfusion magnetic resonance imaging. Magn Reson Med 2005, 54:1423-1429. 183. Chow K, Kellman P, Spottiswoode B, Nielles-Vallespin S, Arai A, Salerno M, Thompson R: Saturation pulse design for quantitative myocardial T 1 mapping. Journal of Cardiovascular Magnetic Resonance 2015, 17:84. 184. Cron GO, Santyr G, Kelcz F: Accurate and rapid quantitative dynamic contrast-enhanced breast MR imaging using spoiled gradient-recalled echoes and bookend T(1) measurements. Magn Reson Med 1999, 42:746-753. 185. Cron G, Kelcz F, Santyr G: Improvement in breast lesion characterization with dynamic contrast-enhanced MRI using pharmacokinetic modeling and bookend T1 measurements. Magn Reson Med 2004, 51:1066-1070. 186. Pintaske J, Martirosian P, Graf H, Erb G, Lodemann K-P, Claussen C, Schick F: Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla. Invest Radiol 2006, 41:213-221. 187. Pintaske J, Martirosian P, Graf H, Erb G, Lodemann K-P, Claussen C, Schick F: Erratum - Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla. Invest Radiol 2006, 41:869-869. 188. Mehta A, Hoffbrand V: Haematology at a glance. 4th edn. Sussex, UK: Wiley Blackwell; 2014. 189. Kellman P, Wilson J, Xue H, Bandettini W, Shanbhag S, Druey K, Ugander M, Arai A: Extracellular volume fraction mapping in the myocardium, part 2: initial clinical experience. Journal of Cardiovascular Magnetic Resonance 2012, 14:64. 190. Fritz-Hansen T, Rostrup E, Larsson H, Søndergaard L, Ring P, Henriksen O: Measurement of the arterial concentration of Gd-DTPA using MRI: A step toward quantitative perfusion imaging. Magn Reson Med 1996, 36:225-231. 191. Fritz-Hansen T, Hove J, Kofoed K, Kelbaek H, Larsson H: Quantification of MRI measured myocardial perfusion reserve in healthy humans: A comparison with positron emission tomography. J Magn Reson Imaging 2008, 27:818-824. 192. Husso M, Sipola P, Kuittinen T, Manninen H, Vainio P, Hartikainen J, Saarakkala S, Töyräs J, Kuikka J: Assessment of myocardial perfusion with MRI using a modified dual bolus method. Physiol Meas 2014, 35:533-547. 193. Su M-Y, Lee B-C, Wu Y-W, Yu H-Y, Chu W-C, Tseng W-Y: Perfusion of residual viable myocardium in nontransmural infarct zone after intervention: MR quantitative myocardial blood flow measurement. Radiology 2008, 249:820-828. 194. Cheng A, Pegg T, Karamitsos T, Searle N, Jerosch-Herold M, Choudhury R, Banning A, Neubauer S, Robson M, Selvanayagam J: Cardiovascular Magnetic Resonance Perfusion Imaging at 3-Tesla for the Detection of Coronary Artery Disease. J Am Coll Cardiol 2007, 49:2440-2449. 195. Lerski RA, de Certaines JD: Performance assessment and quality control in MRI by Eurospin test objects and protocols. Magn Reson Imaging 1993, 11:817-833. 196. Gudbjartsson H, Patz S: The rician distribution of noisy mri data. Magn Reson Med 1995, 34:910-914. 197. Ripley D, McDiarmid A, Kidambi A, Uddin A, Swoboda P, Musa T, Erhayiem B, Bainbridge G, Greenwood J, Plein S, Higgins D: Patient adaptive maximal resolution magnetic resonance myocardial stress perfusion imaging. Journal of magnetic resonance imaging : JMRI 2015. 198. Kellman P, Aletras A, Hsu L-Y, McVeigh E, Arai A: T2* measurement during first-pass contrast-enhanced cardiac perfusion imaging. Magn Reson Med 2006, 56:1132-1134. 199. Karamitsos T, Ntusi N, Francis J, Holloway C, Myerson S, Neubauer S: Feasibility and safety of high-dose adenosine perfusion cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance 2010, 12:66. 200. Ogg RJ, Kingsley RB, Taylor JS: WET, a T1- and B1-Insensitive Water-Suppression Method for in Vivo Localized 1H NMR Spectroscopy. Journal of Magnetic Resonance, Series B 1994, 104:1-10. 201. Broadbent D, Kidambi A, Plein S, Buckley D: Quantitative Dynamic Contrast Enhanced MRI in Acute ST-Elevated Myocardial Infarction: Blood Flow, Microvascular Permeability and Interstitial Volume in Infarct and Peri-Infarct Edema. In Proceedings of the 23rd Scientific Meeting & Exhibition ISMRM; Toronto, Canada. 2015: 517. 202. Handayani A, Triadyaksa P, Dijkstra H, Gert J, van Ooijen P, Prakken N, Schoepf J, Oudkerk M, Vliegenthart R, Sijens P: Intermodel agreement of myocardial blood flow estimation from stress-rest myocardial perfusion magnetic resonance imaging in patients with coronary artery disease. Invest Radiol 2015, 50:275-282. 203. Papanastasiou G, Williams M, Kershaw L, Dweck M, Alam S, Mirsadraee S, Connell M, Gray C, MacGillivray T, Newby D, Semple S: Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus. Journal of Cardiovascular Magnetic Resonance 2015, 17:17. 204. St. John Sutton M, Sharpe N: Left Ventricular Remodeling After Myocardial Infarction. Circulation 2000, 101:2981-2988. 205. Chan W, Duffy S, White D, Gao X-M, Du X-J, Ellims A, Dart A, Taylor A: Acute Left Ventricular Remodeling Following Myocardial Infarction. JACC: Cardiovascular Imaging 2012, 5:884-893. 206. Messroghli D, Walters K, Plein S, Sparrow P, Friedrich M, Ridgway J, Sivananthan M: Myocardial T1 mapping: application to patients with acute and chronic myocardial infarction. Magn Reson Med 2007, 58:34-40. 207. Ugander M, Oki A, Hsu L-Y, Kellman P, Greiser A, Aletras A, Sibley C, Chen M, Bandettini P, Arai A: Extracellular volume imaging by magnetic resonance imaging provides insights into overt and sub-clinical myocardial pathology. Eur Heart J 2012. 208. Cabello J, Burls A, Emparanza J, Bayliss S, Quinn T: Oxygen therapy for acute myocardial infarction. The Cochrane database of systematic reviews 2013, 8. 209. American Heart Association Writing Group on Myocardial S, Registration for Cardiac I, Cerqueira M, Weissman N, Dilsizian V, Jacobs A, Kaul S, Laskey W, Pennell D, Rumberger J, et al: Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart. Circulation 2002, 105:539-542. 210. Papanastasiou G, Williams M, Alam S, Dweck M, Mirsadraee S, Gray C, Connell M, MacGillivray T, Newby D, Semple S: Assessing the reliability of DP and Fermi estimates in single and dual bolus cardiac MR perfusion imaging. Journal of Cardiovascular Magnetic Resonance 2014, 16:P347. 211. Fluckiger J, Benefield B, Harris K, Lee D: Absolute quantification of myocardial blood flow with constrained estimation of the arterial input function: Quantification of MBF With Constrained Estimation. J Magn Reson Imaging 2013, 38:603-609. 212. Fluckiger J, Schabel M, Dibella E: Model-based blind estimation of kinetic parameters in dynamic contrast enhanced (DCE)-MRI. Magn Reson Med 2009, 62:1477-1486. 213. Schabel M, Fluckiger J, DiBella E: A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations. Phys Med Biol 2010, 55:4783. 214. Kratochvíla J, Jiřík R, Bartoš M, Standara M, Starčuk Z, Taxt T: Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI. Magn Reson Med 2016, 75:1355-1365."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.707029"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["DRF-2012-05-155"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/16667/1/Broadbent_DA_Medicine_PhD_2015.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Background: Use of contrast enhanced cardiac magnetic resonance imaging (MRI) for identification of focal pathology (perfusion deficit and scar) is widespread. Quantitative analysis of dynamic contrast enhanced (DCE) MRI data may allow objective assessment of focal and diffuse disease. However it is a complex process and not widely adopted outside the research domain. For accurate quantification temporal variation in relative contrast agent concentration in the myocardium and feeding blood supply must be measured. While MRI signal intensity can be used as a probe of contrast agent concentration its response is non-linear. Aims: In this thesis non-linearity correction methods for quantitative myocardial DCE-MRI are compared, the feasibility of a novel bookend T1 based correction is tested and the method is used in clinical studies to assess myocardial characteristics in health and ischaemic disease. Methods: Signal non-linearity correction methods were compared using simulation, phantom experiments and a volunteer study. Methods compared were independent sampling strategies (dual-bolus and dual-sequence), previously proposed model based correction (native T1 or proton density weighted image based) and bookend T1 based correction which is proposed as a method to account for imperfect magnetisation preparation. The feasibility of the bookend T1 method was tested and characteristics of heathy and diseased myocardium were assessed in clinical studies of ischaemia and infarction. Conclusions: Native T1 based correction has been found to be highly sensitive to imperfect magnetisation preparation, and is thus recommended against. Model based correction using proton density weighted images or bookend T1 data have been found to be more accurate and precise than dual-sampling methods. The clinical studies have demonstrated the feasibility of the bookend T1 based method and have yielded insights into myocardial characteristics in a range of conditions."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Quantitative Dynamic Contrast Enhanced Magnetic Resonance Imaging for Evaluation of the Myocardium in Ischaemic Heart Disease"]}]}],"canonical_facts":{"dc:contributor.advisor":["Buckley, David L","Plein, Sven"],"dc:contributor.sponsor":["National Institute for Health Research"],"dc:creator":["Broadbent, David Andrew"],"dc:date":["2015-10"],"dc:date.issued":["2015-10"],"dc:description.abstract":["Background: Use of contrast enhanced cardiac magnetic resonance imaging (MRI) for identification of focal pathology (perfusion deficit and scar) is widespread. Quantitative analysis of dynamic contrast enhanced (DCE) MRI data may allow objective assessment of focal and diffuse disease. However it is a complex process and not widely adopted outside the research domain. For accurate quantification temporal variation in relative contrast agent concentration in the myocardium and feeding blood supply must be measured. While MRI signal intensity can be used as a probe of contrast agent concentration its response is non-linear. Aims: In this thesis non-linearity correction methods for quantitative myocardial DCE-MRI are compared, the feasibility of a novel bookend T1 based correction is tested and the method is used in clinical studies to assess myocardial characteristics in health and ischaemic disease. Methods: Signal non-linearity correction methods were compared using simulation, phantom experiments and a volunteer study. Methods compared were independent sampling strategies (dual-bolus and dual-sequence), previously proposed model based correction (native T1 or proton density weighted image based) and bookend T1 based correction which is proposed as a method to account for imperfect magnetisation preparation. The feasibility of the bookend T1 method was tested and characteristics of heathy and diseased myocardium were assessed in clinical studies of ischaemia and infarction. Conclusions: Native T1 based correction has been found to be highly sensitive to imperfect magnetisation preparation, and is thus recommended against. Model based correction using proton density weighted images or bookend T1 data have been found to be more accurate and precise than dual-sampling methods. The clinical studies have demonstrated the feasibility of the bookend T1 based method and have yielded insights into myocardial characteristics in a range of conditions."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.707029"],"dc:identifier.grantnumber":["DRF-2012-05-155"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/16667/1/Broadbent_DA_Medicine_PhD_2015.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Academic Unit of Medical Physics (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/16667/"],"dc:relation.references":["1. Broadbent D, Biglands J, Larghat A, Sourbron S, Radjenovic A, Greenwood J, Plein S, Buckley D: Myocardial blood flow at rest and stress measured with dynamic contrast-enhanced MRI: Comparison of a distributed parameter model with a fermi function model. Magn Reson Med 2013, 70:1591-1597. 2. Pennell D, Sechtem U, Higgins C, Manning W, Pohost G, Rademakers F, van Rossum A, Shaw L, Yucel K: Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report. Eur Heart J 2004, 25:1940-1965. 3. Wilke N, Jerosch-Herold M, Stillman AE, Kroll K, Tsekos N, Merkle H, Parrish T, Hu X, Wang Y, Bassingthwaighte J: Concepts of myocardial perfusion imaging in magnetic resonance imaging. Magn Reson Q 1994, 10:249-286. 4. Wilke N, Kroll K, Merkle H, Wang Y, Ishibashi Y, Xu Y, Zhang J, Jerosch-Herold M, Muhler A, Stillman A, et al: Regional myocardial blood volume and flow: First-pass MR imaging with polylysine-Gd-DTPA. Journal of magnetic resonance imaging : JMRI 1995, 5:227-237. 5. Kim R, Chen E-L, Lima Jo, Judd R: Myocardial Gd-DTPA Kinetics Determine MRI Contrast Enhancement and Reflect the Extent and Severity of Myocardial Injury After Acute Reperfused Infarction. Circulation 1996, 94:3318-3326. 6. Kim RJ, Fieno DS, Parrish TB, Harris K, Chen EL, Simonetti O, Bundy J, Finn JP, Klocke FJ, Judd RM: Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function. Circulation 1999, 100:1992-2002. 7. Messroghli D, Radjenovic A, Kozerke S, Higgins D, Sivananthan M, Ridgway J: Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magn Reson Med 2004, 52:141-146. 8. McDiarmid A, Swoboda P, Erhayiem B, Ripley D, Kidambi A, Broadbent D, Higgins D, Greenwood J, Plein S: Single bolus versus split dose gadolinium administration in extra-cellular volume calculation at 3 Tesla. Journal of Cardiovascular Magnetic Resonance 2015, 17:6. 9. McDiarmid A, Higgins D, Broadbent D, Ripley D, Swoboda P, Kidambi A, Erhayiem B, Musa T, Dobson L, Garg P, et al: Split dose versus single bolus gadolinium administration in ecv calculation at 3 Tesla CMR. Journal of Cardiovascular Magnetic Resonance 2015, 17:P257. 10. McDiarmid A, Broadbent D, Higgins D, Swoboda P, Kidambi A, Ripley D, Erhayiem B, Al Musa T, Dobson L, Greenwood J, Plein S: The effect of changes to MOLLI scheme on T1 mapping and extra cellular volume calculation in healthy volunteers with 3 tesla cardiovascular magnetic resonance imaging. Quantitative imaging in medicine and surgery 2015, 5:503-510. 11. McDiarmid A, Swoboda P, Erhayiem B, Lancaster R, Lyall G, Broadbent D, Dobson L, Musa T, Ripley D, Garg P, et al: Athletic Cardiac Adaptation in Males Is a Consequence of Elevated Myocyte Mass. Circulation: Cardiovascular Imaging 2016, 9:e003579. 12. Biglands J, Ripley D, Broadbent D, Higgins D, Swoboda P, McDiarmid A, Garg P, Plein S, Buckley D: A comparison of dual-bolus and dual-sequence quantitative myocardial perfusion techniques. Journal of Cardiovascular Magnetic Resonance 2015, 17:P50. 13. Broadbent D, Higgins D, Ferreira V, Liu A, Marini C, Kramer C, Plein S, Neubauer S, Piechnik S: Pilot Data on Inter-Centre and Inter-Vendor Comparison of MOLLI and ShMOLLI T1 Mapping Variants at 3T. In Joint Annual Meeting ISMRM-ESMRMB; Milan, Italy. 2014: 2449. 14. Dabir D, Child N, Kalra A, Rogers T, Gebker R, Jabbour A, Plein S, Yu C, Otton J, Kidambi A, et al: Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study. Journal of Cardiovascular Magnetic Resonance 2014, 16:69. 15. Kidambi A, Biglands J, Higgins D, Ripley D, Zaman A, Broadbent D, McDiarmid A, Swoboda P, Musa T, Erhayiem B, et al: Susceptibility-weighted cardiovascular magnetic resonance in comparison to T2 and T2 star imaging for detection of intramyocardial hemorrhage following acute myocardial infarction at 3 Tesla. Journal of Cardiovascular Magnetic Resonance 2014, 16:86. 16. Kidambi A, Biglands J, Higgins D, Ripley D, Zaman A, Broadbent D, McDiarmid A, Swoboda P, Musa T, Erhayiem B, et al: Clinical validation of susceptibility-weighted cardiovascular magnetic resonance in comparison to T2 and T2* imaging for detection of intramyocardial hemorrhage following acute myocardial infarction. Journal of Cardiovascular Magnetic Resonance 2015, 17:P117. 17. Kidambi A, Motwani M, Uddin A, Ripley D, McDiarmid A, Swoboda P, Broadbent D, Musa T, Erhayiem B, Leader J, et al: Myocardial extracellular volume estimation by CMR predicts functional recovery following acute myocardial infarction. Journal of Cardiovascular Magnetic Resonance 2015, 17:Q63. 18. Kidambi A, Motwani M, Uddin A, Ripley D, McDiarmid A, Swoboda P, Broadbent D, Musa T, Erhayiem B, Leader J, et al: 125 Myocardial Extracellular Volume Estimation by Cardiovascular Magnetic Resonance Predicts Functional Recovery Following Acute Myocardial Infarction. Heart 2015, 101:A72-A72. 19. Broadbent D, Kidambi A, Biglands J: Cardiovascular Magnetic Resonance Physics for Clinicians. In CMR Pocket Guides (Herzog B, Greenwood J, Plein S eds.): EACVI (CMR Section); 2015. 20. Greenbaum RA, Ho SY, Gibson DG, Becker AE, Anderson RH: Left ventricular fibre architecture in man. Br Heart J 1981, 45:248-263. 21. Bassingthwaighte JB, Yipintsoi T, Harvey RB: Microvasculature of the dog left ventricular myocardium. Microvasc Res 1974, 7:229-249. 22. Roberts J, Wearn J: Quantitative changes in the capillary-muscle relationship in human hearts during normal growth and hypertrophy. Am Heart J 1941, 21:617-633. 23. Archie J: Myocardial oxygen transport. The interrelationship of coronary blood flow, oxygen diffusion and capillary recruitment. J Surg Res 1978, 25:200-210. 24. Botvinick E: Current Methods of Pharmacologic Stress Testing and the Potential Advantages of New Agents. J Nucl Med Technol 2009, 37:14-25. 25. Nesto R, Kowalchuk G: The ischemic cascade: Temporal sequence of hemodynamic, electrocardiographic and symptomatic expressions of ischemia. The American journal of cardiology 1987, 59:C23-C30. 26. Mewton N, Liu CY, Croisille P, Bluemke D, Lima J: Assessment of myocardial fibrosis with cardiovascular magnetic resonance. J Am Coll Cardiol 2011, 57:891-903. 27. Klug G, Mayr A, Schenk S, Esterhammer R, Schocke M, Nocker M, Jaschke W, Pachinger O, Metzler B: Prognostic value at 5 years of microvascular obstruction after acute myocardial infarction assessed by cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance 2012, 14. 28. Bekkers S, Yazdani S, Virmani R, Waltenberger J: Microvascular Obstruction. J Am Coll Cardiol 2010, 55:1649-1660. 29. Braunwald E, Kloner RA: Myocardial reperfusion: a double-edged sword? J Clin Invest 1985, 76:1713-1719. 30. de Waha S, Desch S, Eitel I, Fuernau G, Zachrau J, Leuschner A, Gutberlet M, Schuler G, Thiele H: Impact of early vs. late microvascular obstruction assessed by magnetic resonance imaging on long-term outcome after ST-elevation myocardial infarction: a comparison with traditional prognostic markers. Eur Heart J 2010, 31:2660-2668. 31. Choi KM, Kim RJ, Gubernikoff G, Vargas JD, Parker M, Judd RM: Transmural extent of acute myocardial infarction predicts long-term improvement in contractile function. Circulation 2001, 104:1101-1107. 32. Mahrholdt H, Wagner A, Parker M, Regenfus M, Fieno D, Bonow R, Kim R, Judd R: Relationship of contractile function to transmural extent of infarction in patients with chronic coronary artery disease. J Am Coll Cardiol 2003, 42:505-512. 33. Schuijf JD, Shaw LJ, Wijns W, Lamb HJ, Poldermans D, de Roos A, van der Wall EE, Bax JJ: Cardiac imaging in coronary artery disease: differing modalities. Heart (British Cardiac Society) 2005, 91:1110-1117. 34. Hashemi RH, Bradley WG, Lisanti CK: MRI: The Basics. Updated Third Edition edn: Lippincott Williams & Wilkins; 2012. 35. McRobbie DW, Moore EA, Graves MJ, Prince MR: MRI from Picture to Proton. 2nd edn: Cambridge University Press; 2007. 36. Ridgway J: Cardiovascular magnetic resonance physics for clinicians: part I. Journal of Cardiovascular Magnetic Resonance 2010, 12:71. 37. Garpebring A, Wirestam R, Östlund N, Karlsson M: Effects of inflow and radiofrequency spoiling on the arterial input function in dynamic contrast-enhanced MRI: A combined phantom and simulation study. Magn Reson Med 2011, 65:1670-1679. 38. Preibisch C, Deichmann R: Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles. Magn Reson Med 2009, 61:125-135. 39. Yarnykh V: Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady-state techniques. Magn Reson Med 2010, 63:1610-1626. 40. Donahue K, Burstein D, Manning W, Gray M: Studies of Gd-DTPA relaxivity and proton exchange rates in tissue. Magn Reson Med 1994, 32:66-76. 41. Donahue KM, Weisskoff RM, Burstein D: Water diffusion and exchange as they influence contrast enhancement. J Magn Reson Imaging 1997, 7:102-110. 42. Donahue KM, Weisskoff RM, Chesler DA, Kwong KK, Bogdanov AA, Mandeville JB, Rosen BR: Improving MR quantification of regional blood volume with intravascular T1 contrast agents: accuracy, precision, and water exchange. Magn Reson Med 1996, 36:858-867. 43. Coelho-Filho O, Mongeon F-P, Mitchell R, Moreno H, Nadruz W, Kwong R, Jerosch-Herold M: Role of transcytolemmal water-exchange in magnetic resonance measurements of diffuse myocardial fibrosis in hypertensive heart disease. Circulation Cardiovascular imaging 2013, 6:134-141. 44. Larsson H, Fritz-Hansen T, Rostrup E, Søndergaard L, Ring P, Henriksen O: Myocardial perfusion modeling using MRI. Magn Reson Med 1996, 35:716-726. 45. Kershaw L: Measuring microvascular physiology using quantitative magnetic resonance imaging. University of Manchester, School of Medicine; 2008. 46. Weinmann HJ, Brasch RC, Press WR, Wesbey GE: Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent. Am J Roentgenol 1984, 142:619-624. 47. Koenig S, Spiller M, Brown R, Wolf G: Relaxation of water protons in the intra- and extracellular regions of blood containing Gd(DTPA). Magn Reson Med 1986, 3:791-795. 48. Boudreau RJ, Burbidge S, Sirr S, Loken MK: Comparison of the biodistribution of manganese-54 DTPA and gadolinium-153 DTPA in dogs. Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1987, 28:349-353. 49. Prato F, Wisenberg G, Marshall T, Uksik P, Zabel P: Comparison of the Biodistribution of Gadolinium-153 DTPA and Technetium-99m DTPA in Rats. J Nucl Med 1988, 29:1683-1687. 50. Coelho-Filho O, Shah R, Mitchell R, Neilan T, Moreno H, Simonson B, Kwong R, Rosenzweig A, Das S, Jerosch-Herold M: Quantification of Cardiomyocyte Hypertrophy by Cardiac Magnetic Resonance. Circulation 2013, 128:1225-1233. 51. Sourbron SP, Buckley DL: Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability. Phys Med Biol 2012, 57:R1. 52. Parker G, Roberts C, Macdonald A, Buonaccorsi G, Cheung S, Buckley D, Jackson A, Watson Y, Davies K, Jayson G: Experimentally-derived functional form for a population-averaged high-temporal-resolution arterial input function for dynamic contrast-enhanced MRI. Magn Reson Med 2006, 56:993-1000. 53. Gerber B, Raman S, Nayak K, Epstein F, Ferreira P, Axel L, Kraitchman D: Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art. Journal of Cardiovascular Magnetic Resonance 2008, 10:18. 54. Jerosch-Herold M: Quantification of myocardial perfusion by cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance 2010, 12:57. 55. Garpebring A, Ostlund N, Karlsson M: A novel estimation method for physiological parameters in dynamic contrast-enhanced MRI: application of a distributed parameter model using Fourier-domain calculations. IEEE Trans Med Imaging 2009, 28:1375-1383. 56. Jerosch-Herold M, Wilke N, Stillman AE: Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution. Med Phys 1998, 25:73-84. 57. Kershaw L, Buckley D: Precision in measurements of perfusion and microvascular permeability with T1-weighted dynamic contrast-enhanced MRI. Magn Reson Med 2006, 56:986-992. 58. Cheong LH, Koh TS, Hou Z: An automatic approach for estimating bolus arrival time in dynamic contrast MRI using piecewise continuous regression models. Phys Med Biol 2003, 48:N83. 59. Natsume T, Ishida M, Kitagawa K, Nagata M, Sakuma H, Ichihara T: Theoretical considerations in measurement of time discrepancies between input and myocardial time–signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI. Magn Reson Imaging 2015, 33:1059-1065. 60. Al Jaroudi W, Iskandrian A: Regadenoson: A New Myocardial Stress Agent. J Am Coll Cardiol 2009, 54:1123-1130. 61. Messroghli D, Bainbridge G, Alfakih K, Jones T, Plein S, Ridgway J, Sivananthan M: Assessment of regional left ventricular function: accuracy and reproducibility of positioning standard short-axis sections in cardiac MR imaging. Radiology 2005, 235:229-236. 62. Kramer C, Barkhausen J, Flamm S, Kim R, Nagel E: Standardized cardiovascular magnetic resonance (CMR) protocols 2013 update. Journal of Cardiovascular Magnetic Resonance 2013, 15:91. 63. Motwani M, Maredia N, Fairbairn T, Kozerke S, Greenwood J, Plein S: Assessment of ischaemic burden in angiographic three-vessel coronary artery disease with high-resolution myocardial perfusion cardiovascular magnetic resonance imaging. European heart journal cardiovascular Imaging 2014, 15:701-708. 64. Johnston D, Liu P, Lauffer R, Newell J, Wedeen V, Rosen B, Brady T, Okada R: Use of Gadolinium-DTPA as a Myocardial Perfusion Agent: Potential Applications and Limitations for Magnetic Resonance Imaging. J Nucl Med 1987, 28:871-877. 65. de Roos A, Doornbos J, van der Wall EE, van Voorthuisen AE: MR imaging of acute myocardial infarction: value of Gd-DTPA. Am J Roentgenol 1988, 150:531-534. 66. Biglands J, Radjenovic A, Ridgway J: Cardiovascular magnetic resonance physics for clinicians: part II. Journal of Cardiovascular Magnetic Resonance 2012, 14:66. 67. Flett A, Hayward M, Ashworth M, Hansen M, Taylor A, Elliott P, McGregor C, Moon J: Equilibrium contrast cardiovascular magnetic resonance for the measurement of diffuse myocardial fibrosis: preliminary validation in humans. Circulation 2010, 122:138-144. 68. Fedele F, Montesano T, Ferro-Luzzi M, Di Cesare E, Di Renzi P, Scopinaro F, Agati L, Penco M, Serri F, Vitarelli A, Dagianti A: Identification of viable myocardium in patients with chronic coronary artery disease and left ventricular dysfunction: Role of magnetic resonance imaging. Am Heart J 1994, 128:484-489. 69. Finn P, Nael K, Deshpande V, Ratib O, Laub G: Cardiac MR imaging: state of the technology. Radiology 2006, 241:338-354. 70. Ordovás K, Reddy G, Higgins C: MRI in nonischemic acquired heart disease. Journal of magnetic resonance imaging : JMRI 2008, 27:1195-1213. 71. Ordovas K, Higgins C: Delayed contrast enhancement on MR images of myocardium: past, present, future. Radiology 2011, 261:358-374. 72. Karamitsos T, Francis J, Myerson S, Selvanayagam J, Neubauer S: The role of cardiovascular magnetic resonance imaging in heart failure. J Am Coll Cardiol 2009, 54:1407-1424. 73. Pennell D: Cardiovascular Magnetic Resonance. Circulation 2010, 121:692-705. 74. Jellis C, Martin J, Narula J, Marwick T: Assessment of nonischemic myocardial fibrosis. J Am Coll Cardiol 2010, 56:89-97. 75. Kellman P, Arai A: Cardiac imaging techniques for physicians: Late enhancement. Journal of magnetic resonance imaging : JMRI 2012, 36:529-542. 76. Kim R, Wu E, Rafael A, Chen E-L, Parker M, Simonetti O, Klocke F, Bonow R, Judd R: The Use of Contrast-Enhanced Magnetic Resonance Imaging to Identify Reversible Myocardial Dysfunction. N Engl J Med 2000, 343:1445-1453. 77. Peel S, Morton G, Chiribiri A, Schuster A, Nagel E, Botnar R: Dual Inversion-Recovery MR Imaging Sequence for Reduced Blood Signal on Late Gadolinium-enhanced Images of Myocardial Scar. Radiology 2012, 264:242-249. 78. Stirrat J, Joncas S, Salerno M, Drangova M, White J: Influence of phase correction of late gadolinium enhancement images on scar signal quantification in patients with ischemic and non-ischemic cardiomyopathy. Journal of Cardiovascular Magnetic Resonance 2015, 17:66. 79. Diesbourg L, Prato F, Wisenberg G, Drost D, Marshall T, Carroll E, O'Neill B: Quantification of myocardial blood flow and extracellular volumes using a bolus injection of Gd-DTPA: Kinetic modeling in canine ischemic disease. Magn Reson Med 1992, 23:239-253. 80. Kety S: The theory and applications of the exchange of inert gas at the lungs and tissues. Pharmacol Rev 1951, 3:1-41. 81. Kellman P, Arai A: Imaging sequences for first pass perfusion --a review. Journal of Cardiovascular Magnetic Resonance 2007, 9:525-537. 82. Larsson H, Stubgaard M, Søndergaard L, Henriksen O: In vivo quantification of the unidirectional influx constant for Gd-DTPA diffusion across the myocardial capillaries with MR imaging. Journal of magnetic resonance imaging : JMRI 1994, 4:433-440. 83. Tong C, Prato F, Wisenberg G, Lee T, Carroll E, Sandler D, Wills J: Techniques for the measurement of the local myocardial extraction efficiency for inert diffusible contrast agents such as gadopentate dimeglumine. Magn Reson Med 1993, 30:332-336. 84. Tong C, Prato F, Wisenberg G, Lee T, Carroll E, Sandler D, Wills J, Drost D: Measurement of the extraction efficiency and distribution volume for Gd-DTPA in normal and diseased canine myocardium. Magn Reson Med 1993, 30:337-346. 85. Burstein D, Taratuta E, Manning W: Factors in myocardial “Perfusion” imaging with ultrafast MRI and Gd-DTPA administration. Magn Reson Med 1991, 20:299-305. 86. Atkinson DJ, Burstein D, Edelman RR: First-pass cardiac perfusion: evaluation with ultrafast MR imaging. Radiology 1990, 174:757-762. 87. Larsson HB, Fritz-Hansen T, Rostrup E, Søndergaard L, Ring P, Henriksen O: Myocardial perfusion modeling using MRI. Magn Reson Med 1996, 35:716-726. 88. Vallée JP, Sostman HD, MacFall JR, Wheeler T, Hedlund LW, Spritzer CE, Coleman RE: MRI quantitative myocardial perfusion with compartmental analysis: a rest and stress study. Magn Reson Med 1997, 38:981-989. 89. Tofts PS, Brix G, Buckley DL, Evelhoch JL, Henderson E, Knopp MV, Larsson HB, Lee TY, Mayr NA, Parker GJ, et al: Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. Journal of magnetic resonance imaging : JMRI 1999, 10:223-232. 90. Vallée JP, Lazeyras F, Kasuboski L, Chatelain P, Howarth N, Righetti A, Didier D: Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac function. Journal of magnetic resonance imaging : JMRI 1999, 9:197-203. 91. Nielsen G, Fritz-Hansen T, Dirks C, Jensen G, Larsson H: Evaluation of heart perfusion in patients with acute myocardial infarction using dynamic contrast-enhanced magnetic resonance imaging. Journal of magnetic resonance imaging : JMRI 2004, 20:403-410. 92. Flacke S, Fischer S, Lorenz C: Measurement of the Gadopentetate Dimeglumine Partition Coefficient in Human Myocardium in Vivo: Normal Distribution and Elevation in Acute and Chronic Infarction. Radiology 2001, 218:703-710. 93. Pereira R, Prato F, Sykes J, Wisenberg G: Assessment of myocardial viability using MRI during a constant infusion of Gd-DTPA: Further studies at early and late periods of reperfusion. Magn Reson Med 1999, 42:60-68. 94. Pack N, Dibella E, Wilson B, McGann C: Quantitative myocardial distribution volume from dynamic contrast-enhanced MRI. Magn Reson Imaging 2008, 26:532-542. 95. Jerosch-Herold M, Swingen C, Seethamraju RT: Myocardial blood flow quantification with MRI by model-independent deconvolution. Med Phys 2002, 29:886-897. 96. Jerosch-Herold M, Hershberger RE, Broberg C: Estimation of the Myocardial Extracellular Volume Fraction from Dynamic Contrast-Enhancement Measurements and Comparison with Partition Coefficient Measurements. In Proceedings of the 17th Scientific Meeting & Exhibition ISMRM; Hawaii, USA. 2009: 1743. 97. Pack N, DiBella E: Comparison of myocardial perfusion estimates from dynamic contrast-enhanced magnetic resonance imaging with four quantitative analysis methods. Magn Reson Med 2010, 64:125-137. 98. Hsu B: PET tracers and techniques for measuring myocardial blood flow in patients with coronary artery disease. Journal of biomedical research 2013, 27:452-459. 99. Handayani A, Triadyaksa P, Dijkstra H, Pelgrim GJ, van Ooijen P, Prakken N, Schoepf J, Oudkerk M, Vliegenthart R, Sijens P: Intermodel agreement of myocardial blood flow estimation from stress-rest myocardial perfusion magnetic resonance imaging in patients with coronary artery disease. Invest Radiol 2015, 50:275-282. 100. Biglands J, Magee D, Sourbron S, Plein S, Greenwood J, Radjenovic A: Comparison of the Diagnostic Performance of Four Quantitative Myocardial Perfusion Estimation Methods Used in Cardiac MR Imaging: CE-MARC Substudy. Radiology 2014. 101. Biglands J, Magee D, Boyle R, Larghat A, Plein S, Radjenović A: Evaluation of the effect of myocardial segmentation errors on myocardial blood flow estimates from DCE-MRI. Phys Med Biol 2011, 56:2423-2443. 102. Cernicanu A, Axel L: Theory-based signal calibration with single-point T1 measurements for first-pass quantitative perfusion MRI studies. Acad Radiol 2006, 13:686-693. 103. Christian T, Rettmann D, Aletras A, Liao S, Taylor J, Balaban R, Arai A: Absolute Myocardial Perfusion in Canines Measured by Using Dual-Bolus First-Pass MR Imaging. Radiology 2004, 232:677-684. 104. Hsu L-Y, Rhoads K, Holly J, Kellman P, Aletras A, Arai A: Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans. J Magn Reson Imaging 2006, 23:315-322. 105. Köstler H, Ritter C, Lipp M, Beer M, Hahn D, Sandstede J: Prebolus quantitative MR heart perfusion imaging. Magn Reson Med 2004, 52:296-299. 106. Groothuis J, Kremers F, Beek A, Brinckman S, Tuinenburg A, Jerosch-Herold M, van Rossum A, Hofman M: Comparison of dual to single contrast bolus magnetic resonance myocardial perfusion imaging for detection of significant coronary artery disease. Journal of magnetic resonance imaging : JMRI 2010, 32:88-93. 107. Hsu L-Y, Kellman P, Arai A: Nonlinear myocardial signal intensity correction improves quantification of contrast-enhanced first-pass MR perfusion in humans. J Magn Reson Imaging 2008, 27:793-801. 108. Gatehouse P, Elkington A, Ablitt N, Yang G-Z, Pennell D, Firmin D: Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance. J Magn Reson Imaging 2004, 20:39-45. 109. Sánchez-González J, Fernandez-Jiménez R, Nothnagel N, López-Martín G, Fuster V, Ibañez B: Optimization of dual-saturation single bolus acquisition for quantitative cardiac perfusion and myocardial blood flow maps. Journal of Cardiovascular Magnetic Resonance 2015, 17:21. 110. Kim D, Axel L: Multislice, dual-imaging sequence for increasing the dynamic range of the contrast-enhanced blood signal and CNR of myocardial enhancement at 3T. Journal of magnetic resonance imaging : JMRI 2006, 23:81-86. 111. Kholmovski E, DiBella E: Perfusion MRI with radial acquisition for arterial input function assessment. Magn Reson Med 2007, 57:821-827. 112. Chen D, Sharif B, Dharmakumar R, Thomson L, Bairey Merz N, Berman D, Li D: Improved quantification of myocardial blood flow using highly constrained back projection reconstruction. Magn Reson Med 2014, 72:749-755. 113. Ge L, Kino A, Griswold M, Mistretta C, Carr J, Li D: Myocardial perfusion MRI with sliding-window conjugate-gradient HYPR. Magn Reson Med 2009, 62:835-839. 114. Arheden H, Saeed M, Higgins C, Gao D-W, Bremerich J, Wyttenbach R, Dae M, Wendland M: Measurement of the Distribution Volume of Gadopentetate Dimeglumine at Echo-planar MR Imaging to Quantify Myocardial Infarction: Comparison with 99mTc-DTPA Autoradiography in Rats1. Radiology 1999, 211:698-708. 115. Thornhill R, Prato F, Wisenberg G, White J, Nowell J, Sauer A: Feasibility of the single-bolus strategy for measuring the partition coefficient of Gd-DTPA in patients with myocardial infarction: independence of image delay time and maturity of scar. Magn Reson Med 2006, 55:780-789. 116. Schelbert E, Testa S, Meier C, Ceyrolles W, Levenson J, Blair A, Kellman P, Jones B, Ludwig D, Schwartzman D, et al: Myocardial extravascular extracellular volume fraction measurement by gadolinium cardiovascular magnetic resonance in humans: slow infusion versus bolus. Journal of Cardiovascular Magnetic Resonance 2011, 13:16. 117. Salerno M, Janardhanan R, Jiji R, Brooks J, Adenaw N, Mehta B, Yang Y, Antkowiak P, Kramer C, Epstein F: Comparison of methods for determining the partition coefficient of gadolinium in the myocardium using T1 mapping. Journal of magnetic resonance imaging : JMRI 2012, 38:217-224. 118. Kawel N, Nacif M, Zavodni A, Jones J, Liu S, Sibley C, Bluemke D: T1 mapping of the myocardium: intra-individual assessment of post-contrast T1 time evolution and extracellular volume fraction at 3T for Gd-DTPA and Gd-BOPTA. Journal of Cardiovascular Magnetic Resonance 2012, 14:26. 119. Milanesi M, Barison A, Positano V, Masci P, De Marchi D, Marinelli L, Hardy C, Foo T, Landini L, Lombardi M: Modified cine inversion recovery pulse sequence for the quantification of myocardial T1 and gadolinium partition coefficient. Journal of magnetic resonance imaging : JMRI 2013, 37:109-118. 120. Kawel N, Nacif M, Zavodni A, Jones J, Liu S, Sibley C, Bluemke D: T1 mapping of the myocardium: Intra-individual assessment of the effect of field strength, cardiac cycle and variation by myocardial region. Journal of Cardiovascular Magnetic Resonance 2012, 14:27. 121. Judd R, Atalay M, Rottman G, Zerhouni E: Effects of Myocardial Water Exchange on T1 Enhancement during Bolus Administration of MR Contrast Agents. Magn Reson Med 1995, 33:215-223. 122. Judd R, Reeder S, May-Newman K: Effects of water exchange on the measurement of myocardial perfusion using paramagnetic contrast agents. Magn Reson Med 1999, 41:334-342. 123. Wacker CM, Bock M, Hartlep AW, Beck G, van Kaick G, Ertl G, Bauer WR, Schad LR: Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T*2 and T1 measurements. Magn Reson Med 1999, 41:686-695. 124. Higgins D, Ridgway J, Radjenovic A, Sivananthan M, Smith M: T1 measurement using a short acquisition period for quantitative cardiac applications. Med Phys 2005, 32:1738-1746. 125. Look DC, Locker DR: Time Saving in Measurement of NMR and EPR Relaxation Times. Rev Sci Instrum 1970, 41:250-251. 126. Freeman AJ, Gowland PA, Mansfield P: Optimization of the ultrafast Look-Locker echo-planar imaging T1 mapping sequence. Magn Reson Imaging 1998, 16:765-772. 127. Deichmann R, Haase A: Quantification of T1 values by SNAPSHOT-FLASH NMR imaging. Journal of Magnetic Resonance (1969) 1992, 96:608-612. 128. Scheffler K, Hennig J: T1 quantification with inversion recovery TrueFISP. Magn Reson Med 2001, 45:720-723. 129. Messroghli D, Plein S, Higgins D, Walters K, Jones T, Ridgway J, Sivananthan M: Human myocardium: single-breath-hold MR T1 mapping with high spatial resolution--reproducibility study. Radiology 2006, 238:1004-1012. 130. Messroghli D, Greiser A, Fröhlich M, Dietz R, Schulz-Menger J: Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart. Journal of magnetic resonance imaging : JMRI 2007, 26:1081-1086. 131. Nacif M, Turkbey E, Gai N, Nazarian S, van der Geest R, Noureldin R, Sibley C, Ugander M, Liu S, Arai A, et al: Myocardial T1 mapping with MRI: Comparison of look-locker and MOLLI sequences. Journal of magnetic resonance imaging : JMRI 2011, 34:1367-1373. 132. Shao J, Rapacchi S, Kim-Lien N, Hu P: Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm: FLASH-MOLLI with BLESSPC T1 Mapping. J Magn Reson Imaging 2016, 43:414-425. 133. Marks B, Mitchell DG, Simelaro JP: Breath-holding in healthy and pulmonary-compromised populations: effects of hyperventilation and oxygen inspiration. Journal of magnetic resonance imaging : JMRI 1997, 7:595-597. 134. Lee J, Liu S, Nacif M, Ugander M, Han J, Kawel N, Sibley C, Kellman P, Arai A, Bluemke D: Myocardial T1 and extracellular volume fraction mapping at 3 tesla. Journal of Cardiovascular Magnetic Resonance 2011, 13:75. 135. Kellman P, Arai A, Xue H: T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision. Journal of Cardiovascular Magnetic Resonance 2013, 15:56. 136. Piechnik S, Ferreira V, Dall'Armellina E, Cochlin L, Greiser A, Neubauer S, Robson M: Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. Journal of cardiovascular magnetic resonance 2010, 12. 137. Piechnik S, Ferreira V, Lewandowski A, Ntusi N, Banerjee R, Holloway C, Hofman M, Sado D, Maestrini V, White S, et al: Normal variation of magnetic resonance T1 relaxation times in the human population at 1.5T using ShMOLLI. Journal of Cardiovascular Magnetic Resonance 2013, 15:13. 138. Fontana M, White S, Banypersad S, Sado D, Maestrini V, Flett A, Piechnik S, Neubauer S, Roberts N, Moon J: Comparison of T1 mapping techniques for ECV quantification. Histological validation and reproducibility of ShMOLLI versus multibreath-hold T1 quantification equilibrium contrast CMR. Journal of Cardiovascular Magnetic Resonance 2012, 14:88. 139. Song T, Stainsby J, Ho V, Hood M, Slavin G: Flexible cardiac T1 mapping using a modified look–locker acquisition with saturation recovery. Magn Reson Med 2012, 67:622-627. 140. Xue H, Greiser A, Zuehlsdorff S, Jolly M-P, Guehring J, Arai A, Kellman P: Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting. Magn Reson Med 2013, 69:1408-1420. 141. Chow K, Flewitt J, Green J, Pagano J, Friedrich M, Thompson R: Saturation recovery single-shot acquisition (SASHA) for myocardial T 1 mapping : SASHA for T 1 Mapping. Magn Reson Med 2014, 71:2082-2095. 142. Roujol S, Weingärtner S, Foppa M, Chow K, Kawaji K, Ngo L, Kellman P, Manning W, Thompson R, Nezafat R: Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE. Radiology 2014, 272:683-689. 143. Weingärtner S, Akçakaya M, Basha T, Kissinger K, Goddu B, Berg S, Manning W, Nezafat R: Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability: Improved Imaging of Scar/Fibrosis. Magn Reson Med 2014, 71:1024-1034. 144. Fitts M, Breton E, Kholmovski E, Dosdall D, Vijayakumar S, Hong K, Ranjan R, Marrouche N, Axel L, Kim D: Arrhythmia insensitive rapid cardiac T1 mapping pulse sequence. Magn Reson Med 2013, 70:1274-1282. 145. Stanisz G, Odrobina E, Pun J, Escaravage M, Graham S, Bronskill M, Henkelman M: T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 2005, 54:507-512. 146. Goldfarb J, Mathew S, Reichek N: Quantitative breath-hold monitoring of myocardial gadolinium enhancement using inversion recovery TrueFISP. Magn Reson Med 2005, 53:367-371. 147. Reiter U, Reiter G, Dorr K, Greiser A, Maderthaner R, Fuchsjäger M: Normal diastolic and systolic myocardial T1 values at 1.5-T MR imaging: correlations and blood normalization. Radiology 2014, 271:365-372. 148. Pereira R, Prato F, Wisenberg G, Sykes J: The determination of myocardial viability using Gd-DTPA in a canine model of acute myocardial ischemia and reperfusion. Magn Reson Med 1996, 36:684-693. 149. Pereira R, Prato F, Lekx K, Sykes J, Wisenberg G: Contrast-enhanced MRI for the assessment of myocardial viability after permanent coronary artery occlusion. Magn Reson Med 2000, 44:309-316. 150. Karamitsos T, Neubauer S: The prognostic value of late gadolinium enhancement CMR in nonischemic cardiomyopathies. Current Cardiology Reports 2013, 15. 151. Kuruvilla S, Adenaw N, Katwal A, Lipinski M, Kramer C, Salerno M: Late gadolinium enhancement on cardiac magnetic resonance predicts adverse cardiovascular outcomes in nonischemic cardiomyopathy: a systematic review and meta-analysis. Circulation Cardiovascular imaging 2014, 7:250-258. 152. Klein C, Nekolla S, Balbach T, Schnackenburg B, Nagel E, Fleck E, Schwaiger M: The influence of myocardial blood flow and volume of distribution on late Gd-DTPA kinetics in ischemic heart failure. Journal of magnetic resonance imaging : JMRI 2004, 20:588-594. 153. Selvanayagam J, Jerosch-Herold M, Porto I, Sheridan D, Cheng A, Petersen S, Searle N, Channon K, Banning A, Neubauer S: Resting Myocardial Blood Flow Is Impaired in Hibernating Myocardium. Circulation 2005, 112:3289-3296. 154. Hopp E, Bjørnerud A, Lunde K, Solheim S, Aakhus S, Arnesen H, Forfang K, Edvardsen T, Smith H: Perfusion MRI at rest in subacute and chronic myocardial infarct. Acta Radiol 2013, 54:401-411. 155. Jerosch-Herold M, Sheridan D, Kushner J, Nauman D, Burgess D, Dutton D, Alharethi R, Li D, Hershberger R: Cardiac magnetic resonance imaging of myocardial contrast uptake and blood flow in patients affected with idiopathic or familial dilated cardiomyopathy. American journal of physiology Heart and circulatory physiology 2008, 295. 156. Jacquier A, Kallifatidis A, Guibert N, Giorgi R, Falque C, Thuny F, Croisille P, Clarysse P, Maurel B, Flavian A, et al: Assessment of myocardial partition coefficient of gadolinium (λ) in dilated cardiomyopathy and its impact on segmental and global systolic function. Journal of magnetic resonance imaging : JMRI 2014, 40:1336-1341. 157. Treibel T, White S, Sado D, Hasleton J, Flett A, Herrey A, Hausenloy D, Moon J: Not all LGE is the same. Scar contrast volume of distribution is lower in HCM than in infarction. Journal of Cardiovascular Magnetic Resonance 2012, 14:O95. 158. Ellims A, Iles L, Ling L, Hare J, Kaye D, Taylor A: Diffuse myocardial fibrosis in hypertrophic cardiomyopathy can be identified by cardiovascular magnetic resonance, and is associated with left ventricular diastolic dysfunction. Journal of Cardiovascular Magnetic Resonance 2012, 14:76. 159. Ho C, Abbasi S, Neilan T, Shah R, Chen Y, Heydari B, Cirino A, Lakdawala N, Orav J, González A, et al: T1 Measurements Identify Extracellular Volume Expansion in Hypertrophic Cardiomyopathy Sarcomere Mutation Carriers With and Without Left Ventricular Hypertrophy. Circulation: Cardiovascular Imaging 2013, 6:415-422. 160. Brouwer W, Baars E, Germans T, de Boer K, Beek A, van der Velden J, van Rossum A, Hofman M: In-vivo T1 cardiovascular magnetic resonance study of diffuse myocardial fibrosis in hypertrophic cardiomyopathy. Journal of Cardiovascular Magnetic Resonance 2014, 16:28. 161. Broberg C, Chugh S, Conklin C, Sahn D, Jerosch-Herold M: Quantification of diffuse myocardial fibrosis and its association with myocardial dysfunction in congenital heart disease. Circulation Cardiovascular imaging 2010, 3:727-734. 162. Flett A, Sado D, Quarta G, Mirabel M, Pellerin D, Herrey A, Hausenloy D, Ariti C, Yap J, Kolvekar S, et al: Diffuse myocardial fibrosis in severe aortic stenosis: an equilibrium contrast cardiovascular magnetic resonance study. European Heart Journal – Cardiovascular Imaging 2012, 13:819-826. 163. Neilan T, Coelho-Filho O, Shah R, Feng J, Pena-Herrera D, Mandry D, Pierre-Mongeon F, Heydari B, Francis S, Moslehi J, et al: Myocardial Extracellular Volume by Cardiac Magnetic Resonance Imaging in Patients Treated With Anthracycline-Based Chemotherapy. The American journal of cardiology 2013, 111:717-722. 164. Tham E, Haykowsky M, Chow K, Spavor M, Kaneko S, Khoo N, Pagano J, Mackie A, Thompson R: Diffuse myocardial fibrosis by T1-mapping in children with subclinical anthracycline cardiotoxicity: relationship to exercise capacity, cumulative dose and remodeling. Journal of Cardiovascular Magnetic Resonance 2013, 15:48. 165. Rao A, Shah R, Garg R, Abbasi S, Neilan T, Perlstein T, Di Carli M, Jerosch-Herold M, Kwong R, Adler G: Aldosterone and myocardial extracellular matrix expansion in type 2 diabetes mellitus. The American journal of cardiology 2013, 112:73-78. 166. Khan JN, Wilmot EG, Leggate M, Singh A, Yates T, Nimmo M, Khunti K, Horsfield M, Biglands J, Clarysse P, et al: Subclinical diastolic dysfunction in young adults with Type 2 diabetes mellitus: a multiparametric contrast-enhanced cardiovascular magnetic resonance pilot study assessing potential mechanisms. European heart journal cardiovascular Imaging 2014. 167. Coelho-Filho O, Shah R, Neilan T, Mattos Souza J, Jose C, Carlos F, Lindemberg da Mota S-F, Martins de Oliveira P, Severino E, Jerosch-Herold M, Petrucci O: Characterization of both myocardial extracellular volume expansion and myocyte hypertrophy by CMR in heart transplantation recipients without active rejection: implications for early cardiac remodeling. Journal of Cardiovascular Magnetic Resonance 2015, 17:O75. 168. Parnham S, Gleadle J, Leong D, Grover S, Bradbrook C, Woodman R, De Pasquale C, Selvanayagam J: Myocardial perfusion is impaired in asymptomatic renal and liver transplant recipients: a cardiovascular magnetic resonance study. Journal of Cardiovascular Magnetic Resonance 2015, 17:56. 169. Banypersad S, Sado D, Flett A, Gibbs S, Pinney J, Maestrini V, Cox A, Fontana M, Whelan C, Wechalekar A, et al: Quantification of myocardial extracellular volume fraction in systemic AL amyloidosis: an equilibrium contrast cardiovascular magnetic resonance study. Circulation Cardiovascular imaging 2013, 6:34-39. 170. Thuny F, Lovric D, Schnell F, Bergerot C, Ernande L, Cottin V, Derumeaux G, Croisille P: Quantification of Myocardial Extracellular Volume Fraction with Cardiac MR Imaging for Early Detection of Left Ventricle Involvement in Systemic Sclerosis. Radiology 2014, 271:373-380. 171. Edwards N, Moody W, Yuan M, Hayer M, Ferro C, Townend J, Steeds R: Diffuse interstitial fibrosis and myocardial dysfunction in early chronic kidney disease. The American journal of cardiology 2015, 115:1311-1317. 172. Liu C-Y, Liu Y-C, Wu C, Armstrong A, Volpe G, van der Geest R, Liu Y, Hundley W, Gomes A, Liu S, et al: Evaluation of Age-Related Interstitial Myocardial Fibrosis With Cardiac Magnetic Resonance Contrast-Enhanced T1 Mapping. J Am Coll Cardiol 2013, 62:1280-1287. 173. Neilan T, Coelho-Filho O, Shah R, Abbasi S, Heydari B, Watanabe E, Chen Y, Mandry D, Pierre-Mongeon F, Blankstein R, et al: Myocardial extracellular volume fraction from T1 measurements in healthy volunteers and mice: relationship to aging and cardiac dimensions. JACC Cardiovascular imaging 2013, 6:672-683. 174. Miller C, Naish J, Bishop P, Coutts G, Clark D, Zhao S, Ray S, Yonan N, Williams S, Flett A, et al: Comprehensive Validation of Cardiovascular Magnetic Resonance Techniques for the Assessment of Myocardial Extracellular Volume. Circulation: Cardiovascular Imaging 2013. 175. Christophe de Meester de R, Bouzin C, Lazam S, Boulif J, Amzulescu M, Melchior J, Pasquet As, Vancraeynest D, Pouleur A-C, Vanoverschelde J-L, Gerber B: Histological Validation of measurement of diffuse interstitial myocardial fibrosis by myocardial extravascular volume fraction from Modified Look-Locker imaging (MOLLI) T1 mapping at 3T. Journal of Cardiovascular Magnetic Resonance 2015, 17:48. 176. Kellman P, Hansen M: T1-mapping in the heart: accuracy and precision. Journal of Cardiovascular Magnetic Resonance 2014, 16:2. 177. Broadbent DA, Biglands JD, Ripley DP, Higgins DM, Greenwood JP, Plein S, Buckley DL: Sensitivity of quantitative myocardial dynamic contrast-enhanced MRI to saturation pulse efficiency, noise and t1 measurement error: Comparison of nonlinearity correction methods. Magn Reson Med 2016, 75:1290-1300. 178. Broadbent D, Biglands J, Ripley D, Plein S, Buckley D: Comparison of non-linearity correction methods for quantitative myocardial perfusion MRI. Journal of Cardiovascular Magnetic Resonance 2015, 17:P45. 179. Utz W, Niendorf T, Wassmuth R, Messroghli D, Dietz R, Schulz-Menger J: Contrast-dose relation in first-pass myocardial MR perfusion imaging. J Magn Reson Imaging 2007, 25:1131-1135. 180. Kim D, Gonen O, Oesingmann N, Axel L: Comparison of the effectiveness of saturation pulses in the heart at 3T. Magn Reson Med 2008, 59:209-215. 181. Kim D, Oesingmann N, McGorty K: Hybrid adiabatic-rectangular pulse train for effective saturation of magnetization within the whole heart at 3 T. Magn Reson Med 2009, 62:1368-1378. 182. Kim D, Cernicanu A, Axel L: B0 and B1-insensitive uniform T1-weighting for quantitative, first-pass myocardial perfusion magnetic resonance imaging. Magn Reson Med 2005, 54:1423-1429. 183. Chow K, Kellman P, Spottiswoode B, Nielles-Vallespin S, Arai A, Salerno M, Thompson R: Saturation pulse design for quantitative myocardial T 1 mapping. Journal of Cardiovascular Magnetic Resonance 2015, 17:84. 184. Cron GO, Santyr G, Kelcz F: Accurate and rapid quantitative dynamic contrast-enhanced breast MR imaging using spoiled gradient-recalled echoes and bookend T(1) measurements. Magn Reson Med 1999, 42:746-753. 185. Cron G, Kelcz F, Santyr G: Improvement in breast lesion characterization with dynamic contrast-enhanced MRI using pharmacokinetic modeling and bookend T1 measurements. Magn Reson Med 2004, 51:1066-1070. 186. Pintaske J, Martirosian P, Graf H, Erb G, Lodemann K-P, Claussen C, Schick F: Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla. Invest Radiol 2006, 41:213-221. 187. Pintaske J, Martirosian P, Graf H, Erb G, Lodemann K-P, Claussen C, Schick F: Erratum - Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla. Invest Radiol 2006, 41:869-869. 188. Mehta A, Hoffbrand V: Haematology at a glance. 4th edn. Sussex, UK: Wiley Blackwell; 2014. 189. Kellman P, Wilson J, Xue H, Bandettini W, Shanbhag S, Druey K, Ugander M, Arai A: Extracellular volume fraction mapping in the myocardium, part 2: initial clinical experience. Journal of Cardiovascular Magnetic Resonance 2012, 14:64. 190. Fritz-Hansen T, Rostrup E, Larsson H, Søndergaard L, Ring P, Henriksen O: Measurement of the arterial concentration of Gd-DTPA using MRI: A step toward quantitative perfusion imaging. Magn Reson Med 1996, 36:225-231. 191. Fritz-Hansen T, Hove J, Kofoed K, Kelbaek H, Larsson H: Quantification of MRI measured myocardial perfusion reserve in healthy humans: A comparison with positron emission tomography. J Magn Reson Imaging 2008, 27:818-824. 192. Husso M, Sipola P, Kuittinen T, Manninen H, Vainio P, Hartikainen J, Saarakkala S, Töyräs J, Kuikka J: Assessment of myocardial perfusion with MRI using a modified dual bolus method. Physiol Meas 2014, 35:533-547. 193. Su M-Y, Lee B-C, Wu Y-W, Yu H-Y, Chu W-C, Tseng W-Y: Perfusion of residual viable myocardium in nontransmural infarct zone after intervention: MR quantitative myocardial blood flow measurement. Radiology 2008, 249:820-828. 194. Cheng A, Pegg T, Karamitsos T, Searle N, Jerosch-Herold M, Choudhury R, Banning A, Neubauer S, Robson M, Selvanayagam J: Cardiovascular Magnetic Resonance Perfusion Imaging at 3-Tesla for the Detection of Coronary Artery Disease. J Am Coll Cardiol 2007, 49:2440-2449. 195. Lerski RA, de Certaines JD: Performance assessment and quality control in MRI by Eurospin test objects and protocols. Magn Reson Imaging 1993, 11:817-833. 196. Gudbjartsson H, Patz S: The rician distribution of noisy mri data. Magn Reson Med 1995, 34:910-914. 197. Ripley D, McDiarmid A, Kidambi A, Uddin A, Swoboda P, Musa T, Erhayiem B, Bainbridge G, Greenwood J, Plein S, Higgins D: Patient adaptive maximal resolution magnetic resonance myocardial stress perfusion imaging. Journal of magnetic resonance imaging : JMRI 2015. 198. Kellman P, Aletras A, Hsu L-Y, McVeigh E, Arai A: T2* measurement during first-pass contrast-enhanced cardiac perfusion imaging. Magn Reson Med 2006, 56:1132-1134. 199. Karamitsos T, Ntusi N, Francis J, Holloway C, Myerson S, Neubauer S: Feasibility and safety of high-dose adenosine perfusion cardiovascular magnetic resonance. Journal of Cardiovascular Magnetic Resonance 2010, 12:66. 200. Ogg RJ, Kingsley RB, Taylor JS: WET, a T1- and B1-Insensitive Water-Suppression Method for in Vivo Localized 1H NMR Spectroscopy. Journal of Magnetic Resonance, Series B 1994, 104:1-10. 201. Broadbent D, Kidambi A, Plein S, Buckley D: Quantitative Dynamic Contrast Enhanced MRI in Acute ST-Elevated Myocardial Infarction: Blood Flow, Microvascular Permeability and Interstitial Volume in Infarct and Peri-Infarct Edema. In Proceedings of the 23rd Scientific Meeting & Exhibition ISMRM; Toronto, Canada. 2015: 517. 202. Handayani A, Triadyaksa P, Dijkstra H, Gert J, van Ooijen P, Prakken N, Schoepf J, Oudkerk M, Vliegenthart R, Sijens P: Intermodel agreement of myocardial blood flow estimation from stress-rest myocardial perfusion magnetic resonance imaging in patients with coronary artery disease. Invest Radiol 2015, 50:275-282. 203. Papanastasiou G, Williams M, Kershaw L, Dweck M, Alam S, Mirsadraee S, Connell M, Gray C, MacGillivray T, Newby D, Semple S: Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus. Journal of Cardiovascular Magnetic Resonance 2015, 17:17. 204. St. John Sutton M, Sharpe N: Left Ventricular Remodeling After Myocardial Infarction. Circulation 2000, 101:2981-2988. 205. Chan W, Duffy S, White D, Gao X-M, Du X-J, Ellims A, Dart A, Taylor A: Acute Left Ventricular Remodeling Following Myocardial Infarction. JACC: Cardiovascular Imaging 2012, 5:884-893. 206. Messroghli D, Walters K, Plein S, Sparrow P, Friedrich M, Ridgway J, Sivananthan M: Myocardial T1 mapping: application to patients with acute and chronic myocardial infarction. Magn Reson Med 2007, 58:34-40. 207. Ugander M, Oki A, Hsu L-Y, Kellman P, Greiser A, Aletras A, Sibley C, Chen M, Bandettini P, Arai A: Extracellular volume imaging by magnetic resonance imaging provides insights into overt and sub-clinical myocardial pathology. Eur Heart J 2012. 208. Cabello J, Burls A, Emparanza J, Bayliss S, Quinn T: Oxygen therapy for acute myocardial infarction. The Cochrane database of systematic reviews 2013, 8. 209. American Heart Association Writing Group on Myocardial S, Registration for Cardiac I, Cerqueira M, Weissman N, Dilsizian V, Jacobs A, Kaul S, Laskey W, Pennell D, Rumberger J, et al: Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart. Circulation 2002, 105:539-542. 210. Papanastasiou G, Williams M, Alam S, Dweck M, Mirsadraee S, Gray C, Connell M, MacGillivray T, Newby D, Semple S: Assessing the reliability of DP and Fermi estimates in single and dual bolus cardiac MR perfusion imaging. Journal of Cardiovascular Magnetic Resonance 2014, 16:P347. 211. Fluckiger J, Benefield B, Harris K, Lee D: Absolute quantification of myocardial blood flow with constrained estimation of the arterial input function: Quantification of MBF With Constrained Estimation. J Magn Reson Imaging 2013, 38:603-609. 212. Fluckiger J, Schabel M, Dibella E: Model-based blind estimation of kinetic parameters in dynamic contrast enhanced (DCE)-MRI. Magn Reson Med 2009, 62:1477-1486. 213. Schabel M, Fluckiger J, DiBella E: A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations. Phys Med Biol 2010, 55:4783. 214. Kratochvíla J, Jiřík R, Bartoš M, Standara M, Starčuk Z, Taxt T: Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI. Magn Reson Med 2016, 75:1355-1365."],"dcterms:accessrights":["public"],"dc:title":["Quantitative Dynamic Contrast Enhanced Magnetic Resonance Imaging for Evaluation of the Myocardium in Ischaemic Heart Disease"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000258924762"]},"updated_at":"2026-11-18T22:20:20Z"}