{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:18372"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:18372","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Modular Multilevel Cascaded Flying Capacitor STATCOM for Balanced and Unbalanced Load Compensation","abstract":"Voltage and current unbalance are major problems in distribution networks, particularly with the integration of distributed generation systems. One way of mitigating these issues is by injecting negative sequence current into the distribution network using a Static Synchronous Compensator (STATCOM) which normally also regulates the voltage and power factor. The benefits of modularity and scalability offered by Modular Multilevel Cascaded Converters (MMCC) make them suitable for STATCOM application. A number of different types of MMCC may be used, classified according to the sub-module circuit topology used. Their performance features and operational ranges for unbalanced load compensation are evaluated and quantified in this research. This thesis investigates the use of both single star and single delta configured five-level Flying Capacitor (FC) converter MMCC based STATCOMs for unbalanced load compensation. A detailed study is carried out to compare this type of sub-module with several other types namely: half bridge, 3-L H-bridge and 3-L FC half bridge, and reveals the one best suited to STATCOM operation. With the choice of 5-L FC H-bridge as the sub-module for STATCOM operation, a detailed investigation is also performed to decide which pulse width modulation technique is the best. This was based on the assessment of total harmonic distortion, power loss, sub-module switch utilization and natural balancing of inner flying capacitors. Two new modulation techniques of swapped-carrier PWM (SC-PWM) along with phase disposed and phase shifted PWM (PS-PWM) are analyzed under these four performance metrics. A novel contribution of this research is the development of a new space vector modulation technique using an overlapping hexagon technique. This space vector strategy offers benefits of eliminating control complexity and improving waveform quality, unlike the case of multilevel space vector technique. The simulation and experimental results show that this method provides superior performance and is applicable for other MMCC sub-modules. Another contribution is the analysis and quantification of operating ranges of both single star and delta MMCCs in rating the cluster dc-link voltage (star) and current (delta) for unbalanced load compensation. A novel method of extending the operating capabilities of both configurations uses a third harmonic injection method. An experimental investigation validates the operating range extension compared to the pure sinusoidal zero sequence voltage and current injection. Also, the superiority of the single delta configured MMCC for unbalanced loading compensation is validated.","abstract_html":"Voltage and current unbalance are major problems in distribution networks, particularly with the integration of distributed generation systems. One way of mitigating these issues is by injecting negative sequence current into the distribution network using a Static Synchronous Compensator (STATCOM) which normally also regulates the voltage and power factor. The benefits of modularity and scalability offered by Modular Multilevel Cascaded Converters (MMCC) make them suitable for STATCOM application. A number of different types of MMCC may be used, classified according to the sub-module circuit topology used. Their performance features and operational ranges for unbalanced load compensation are evaluated and quantified in this research. This thesis investigates the use of both single star and single delta configured five-level Flying Capacitor (FC) converter MMCC based STATCOMs for unbalanced load compensation. A detailed study is carried out to compare this type of sub-module with several other types namely: half bridge, 3-L H-bridge and 3-L FC half bridge, and reveals the one best suited to STATCOM operation. With the choice of 5-L FC H-bridge as the sub-module for STATCOM operation, a detailed investigation is also performed to decide which pulse width modulation technique is the best. This was based on the assessment of total harmonic distortion, power loss, sub-module switch utilization and natural balancing of inner flying capacitors. Two new modulation techniques of swapped-carrier PWM (SC-PWM) along with phase disposed and phase shifted PWM (PS-PWM) are analyzed under these four performance metrics. A novel contribution of this research is the development of a new space vector modulation technique using an overlapping hexagon technique. This space vector strategy offers benefits of eliminating control complexity and improving waveform quality, unlike the case of multilevel space vector technique. The simulation and experimental results show that this method provides superior performance and is applicable for other MMCC sub-modules. Another contribution is the analysis and quantification of operating ranges of both single star and delta MMCCs in rating the cluster dc-link voltage (star) and current (delta) for unbalanced load compensation. A novel method of extending the operating capabilities of both configurations uses a third harmonic injection method. An experimental investigation validates the operating range extension compared to the pure sinusoidal zero sequence voltage and current injection. Also, the superiority of the single delta configured MMCC for unbalanced loading compensation is validated.","abstract_has_math":false,"creators":["Oghorada, Oghenewvogaga"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Zhang, Li"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-08","date_published":"2017-08","updated_at":"2026-11-18T22:23:50Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.727190"],"render_values":[{"text":"uk.bl.ethos.727190","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/18372/1/Oghorada%20Ogaga%20Electronic%20and%20Electrical%20Engineering_PhD_2017%20Final%20Version.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A18372","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhang, Li"]},{"key":"dc:creator","label":"Author","values":["Oghorada, Oghenewvogaga"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-08-17"]},{"key":"dc:date.issued","label":"Date","values":["2017-08"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Integrated Information Systems (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/18372/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] H. C. Chen, and P. T. Cheng, “A DC Bus Voltage Balancing Technique for the Cascaded H-Bridge STATCOM With Improved Reliability Under Grid Faults,” IEEE Transactions on Industry Applications, vol. 53, no. 2, pp. 1263-1270, 2017. [2] L. Wang, C. H. Chang, B. L. Kuan, and A. V. Prokhorov, “Stability Improvement of a Two-Area Power System Connected With an Integrated Onshore and Offshore Wind Farm Using a STATCOM,” IEEE Transactions on Industry Applications, vol. 53, no. 2, pp. 867-877, 2017. [3] X. Liu, J. Lv, C. Gao, Z. Chen, and S. Chen, “A Novel STATCOM Based on Diode-Clamped Modular Multilevel Converters,” IEEE Transactions on Power Electronics, vol. 32, no. 8, pp. 5964-5977, 2017. [4] M. Moghbel, M. A. S. Masoum, A. Fereidouni, and S. Deilami, “Optimal Sizing, Siting and Operation of Custom Power Devices with STATCOM and APLC Functions for Real-Time Reactive Power and Network Voltage Quality Control of Smart Grid,” IEEE Transactions on Smart Grid, vol. PP, no. 99, pp. 1-1, 2017. [5] R. K. Varma, and R. Salehi, “SSR Mitigation With a New Control of PV Solar Farm as STATCOM (PV-STATCOM),” IEEE Transactions on Sustainable Energy, vol. PP, no. 99, pp. 1-1, 2017. [6] D. Lu, J. Wang, J. Yao, S. Wang, J. Zhu, H. Hu, and L. Zhang, “Clustered Voltage Balancing Mechanism and its Control Strategy for Star-Connected Cascaded H-Bridge STATCOM,” IEEE Transactions on Industrial Electronics, vol. PP, no. 99, pp. 1-1, 2017. [7] B. Lei, and S. Fei, “control for STATCOM to improve voltage stability of power system,” Electronics Letters, vol. 53, no. 10, pp. 670-672, 2017. [8] M. B. Shadmand, M. Mosa, R. S. Balog, and H. Abu-Rub, “Model Predictive Control of a Capacitorless Matrix Converter-Based STATCOM,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 5, no. 2, pp. 796-808, 2017. [9] Z. He, F. Ma, Q. Xu, Y. Chen, C. Li, M. Li, J. M. Guerrero, and A. Luo, “Reactive Power Strategy of Cascaded Delta-Connected STATCOM Under Asymmetrical Voltage Conditions,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 5, no. 2, pp. 784-795, 2017. [10] G. Farivar, C. D. Townsend, B. Hredzak, J. Pou, and V. G. Agelidis, “Passive Reactor Compensated Cascaded H-Bridge Multilevel LC-StatCom,” IEEE Transactions on Power Electronics, vol. 32, no. 11, pp. 8338-8348, 2017. [11] J. Khodaparast, M. Khederzadeh, F. F. d. Silva, and C. L. Bak, “Variation of UPFC controllable parameters during power swing and their impacts on distance relay,” IET Generation, Transmission & Distribution, vol. 11, no. 7, pp. 1735-1744, 2017. [12] J. Khodaparast, M. Khederzadeh, F. F. d. Silva, and C. L. Bak, “Power Swing Detection in UPFC-Compensated Line by Phase Angle of Current,” IEEE Journal on Emerging and Selected Topics in Circuits and Systems, vol. PP, no. 99, pp. 1-10, 2017. [13] F. M. Albatsh, S. Mekhilef, S. Ahmad, and H. Mokhlis, “Fuzzy Logic Based UPFC and Laboratory Prototype Validation for Dynamic Power Flow Control in Transmission Lines,” IEEE Transactions on Industrial Electronics, vol. PP, no. 99, pp. 1-1, 2017. [14] P. Li, G. P. Adam, D. Holliday, S. J. Finney, and B. W. Williams, “Simulation study of FACTS devices based on AC&#8211;AC modular multilevel hexagonal chopper,” IET Power Electronics, vol. 10, no. 8, pp. 919-930, 2017. [15] M. Raza, E. Prieto-Araujo, and O. Gomis-Bellmunt, “Small Signal Stability Analysis of Offshore AC Network having Multiple VSC-HVDC System,” IEEE Transactions on Power Delivery, vol. PP, no. 99, pp. 1-1, 2017. [16] A. Raza, X. Dianguo, L. Yuchao, S. Xunwen, B. W. Williams, and C. Cecati, “Coordinated Operation and Control of VSC Based Multiterminal High Voltage DC Transmission Systems,” IEEE Transactions on Sustainable Energy, vol. 7, no. 1, pp. 364-373, 2016. [17] G. P. Adam, I. A. Gowaid, S. J. Finney, D. Holliday, and B. W. Williams, “Review of dc&#x2013;dc converters for multi-terminal HVDC transmission networks,” IET Power Electronics, vol. 9, no. 2, pp. 281-296, 2016. [18] G. P. Adam, and B. W. Williams, “Multi-pole voltage source converter HVDC transmission systems,” IET Generation, Transmission & Distribution, vol. 10, no. 2, pp. 496-507, 2016. [19] R. Li, L. Xu, L. Yao, and B. W. Williams, “Active Control of DC Fault Currents in DC Solid-State Transformers During Ride-Through Operation of Multi-Terminal HVDC Systems,” IEEE Transactions on Energy Conversion, vol. 31, no. 4, pp. 1336-1346, 2016. [20] R. Li, J. E. Fletcher, L. Xu, and B. W. Williams, “Enhanced Flat-Topped Modulation for MMC Control in HVDC Transmission Systems,” IEEE Transactions on Power Delivery, vol. 32, no. 1, pp. 152-161, 2017. [21] R. Li, J. E. Fletcher, and B. W. Williams, “Influence of third harmonic injection on modular multilevel converter -based high-voltage direct current transmission systems,” IET Generation, Transmission & Distribution, vol. 10, no. 11, pp. 2764-2770, 2016. [22] J. Wang, J. Liang, C. Wang, and X. Dong, “Circulating Current Suppression for MMC-HVDC under Unbalanced Grid Conditions,” IEEE Transactions on Industry Applications, vol. 53, no. 4, pp. 3250-3259, 2017. [23] H. Mahmoudi, M. Aleenejad, and R. Ahmadi, “Modulated Model Predictive Control of Modular Multilevel Converters in VSC-HVDC Systems,” IEEE Transactions on Power Delivery, vol. PP, no. 99, pp. 1-1, 2017. [24] S. M. Muyeen, and H. M. Hasanien, “Operation and control of HVDC stations using continuous mixed <italic>p</italic>-norm-based adaptive fuzzy technique,” IET Generation, Transmission & Distribution, vol. 11, no. 9, pp. 2275-2282, 2017. [25] X. Yang, Y. Xue, B. Chen, Z. Lin, T. Q. Zheng, and Y. Li, “Novel modular multilevel converter against DC faults for HVDC applications,” CSEE Journal of Power and Energy Systems, vol. 3, no. 2, pp. 140-149, 2017. [26] N. G. Hingorani, “High Power Electronics and flexible AC Transmission System,” IEEE Power Engineering Review, vol. 8, no. 7, pp. 3-4, 1988. [27] E. W. Kimbark, “Improvement of System Stability by Switched Series Capacitors,” IEEE Transactions on Power Apparatus and Systems, vol. PAS-85, no. 2, pp. 180-188, 1966. [28] A. Keri, “Improving transmission system performance using controlled series capacitors,” CIGRE, 1992. [29] ABB, “Available: http://new.abb.com/facts.” [30] Siemens, “Available: http://www.energy.siemens.com/hq/en/power-transmission/facts/.” [31] A. Edris, “Proposed terms and definitions for flexible AC transmission system (FACTS),” IEEE Transactions on Power Delivery, vol. 12, no. 4, pp. 1848-1853, 1997. [32] ABB, “A matter of FACTS - Deliver more high quality power,” 2015. [33] ALSTOM, “Flexible AC Transmission Systems: Solutions to Optimize Network Performance,” 2014. [34] A. SIEMENS, “Discover the World of FACTS Technology–Technical Compendium,” Power Transmission and Distribution, Erlangen, Germany, 2006. [35] C. J. Nwobu, “Control of a Modular Multilevel Flying Capacitor Based STATCOM for Distribution Systems,” University of Leeds, 2016. [36] F. J. Chivite-Zabalza, P. Izurza, G. Calvo, and M. A. Rodriguez, \"Laboratory tests of the voltage source converter for a 47 MVAR Series Static Synchronous Compensator for the Spanish high voltage transmission grid.\" pp. 1-6. [37] V. S. P. Cheung, H. S. H. Chung, K. W. Wang, and A. W. L. Lo, “Paralleling Multiple Static Synchronous Series Compensators Using Daisy-Chained Transformers,” IEEE Transactions on Power Electronics, vol. 29, no. 6, pp. 2764-2773, 2014. [38] M. Saradarzadeh, S. Farhangi, J. L. Schanen, P. O. Jeannin, and D. Frey, “Application of cascaded H-bridge distribution-static synchronous series compensator in electrical distribution system power flow control,” IET Power Electronics, vol. 5, no. 9, pp. 1660-1675, 2012. [39] C. Schauder, E. Stacey, M. Lund, L. Gyugyi, L. Kovalsky, A. Keri, A. Mehraban, and A. Edris, “AEP UPFC project: installation, commissioning and operation of the &plusmn;160 MVA STATCOM (phase I),” IEEE Transactions on Power Delivery, vol. 13, no. 4, pp. 1530-1535, 1998. [40] S. Y. Kim, J. S. Yoon, B. H. Chang, and D. H. Baek, \"The operation experience of KEPCO UPFC.\" pp. 2502-2505 Vol. 3. [41] Y. Sumi, Y. Harumoto, T. Hasegawa, M. Yano, K. Ikeda, and T. Matsuura, “New Static Var Control Using Force-Commutated Inverters,” IEEE Transactions on Power Apparatus and Systems, vol. PAS-100, no. 9, pp. 4216-4224, 1981. [42] K. Matsuno, I. Iyoda, and Y. Oue, \"An experience of FACTS development 1980s and 1990s.\" pp. 1378-1381 vol.2. [43] C. Schauder, M. Gernhardt, E. Stacey, T. Lemak, L. Gyugyi, T. W. Cease, and A. Edris, “Operation of &plusmn;100 MVAr TVA STATCON,” IEEE Transactions on Power Delivery, vol. 12, no. 4, pp. 1805-1811, 1997. [44] K. H. Sobtink, K. W. Renz, and H. Tyll, \"Operational experience and field tests of the SVG at Rejsby Hede.\" pp. 318-322 vol.1. [45] ABB, “Reference List,” 2015. [46] L. Gyugyi, “Dynamic compensation of AC transmission lines by solid-state synchronous voltage sources,” IEEE Transactions on Power Delivery, vol. 9, no. 2, pp. 904-911, 1994. [47] L. Gyugyi, “Unified power-flow control concept for flexible AC transmission systems,” IEE Proceedings C - Generation, Transmission and Distribution, vol. 139, no. 4, pp. 323-331, 1992. [48] L. Gyugyi, C. D. Schauder, and K. K. Sen, “Static Synchronous Series Compensator: A Solid-State Approach to the Series Compensation of Transmission Lines,” IEEE Power Engineering Review, vol. 17, no. 1, pp. 62-62, 1997. [49] S. Khomfoi, and L. M. Tolbert, “Multilevel power converters,” Power electronics handbook, pp. 451-482, 2007. [50] S. Kouro, M. Malinowski, K. Gopakumar, J. Pou, L. G. Franquelo, W. Bin, J. Rodriguez, M. A. Perez, and J. I. Leon, “Recent Advances and Industrial Applications of Multilevel Converters,” Industrial Electronics, IEEE Transactions on, vol. 57, no. 8, pp. 2553-2580, 2010. [51] L. Zhang, S. J. Watkins, and W. Shepherd, \"Analysis and control of a multi-level flying capacitor inverter.\" pp. 66-71. [52] L. Xu, and V. G. Agelidis, “Flying capacitor multilevel PWM converter based UPFC,” IEE Proceedings - Electric Power Applications, vol. 149, no. 4, pp. 304-310, 2002. [53] J. Rodriguez, L. Jih-Sheng, and P. Fang Zheng, “Multilevel inverters: a survey of topologies, controls, and applications,” IEEE Transactions on Industrial Electronics, vol. 49, no. 4, pp. 724-738, 2002. [54] T. Meynard, and H. Foch, \"Multi-level conversion: high voltage choppers and voltage-source inverters.\" pp. 397-403. [55] L. Jih-Sheng, and P. Fang Zheng, “Multilevel converters-a new breed of power converters,” IEEE Transactions on Industry Applications, vol. 32, no. 3, pp. 509-517, 1996. [56] M. L. Heldwein, S. A. Mussa, and I. Barbi, “Three-Phase Multilevel PWM Rectifiers Based on Conventional Bidirectional Converters,” IEEE Transactions on Power Electronics, vol. 25, no. 3, pp. 545-549, 2010. [57] L. Demas, T. A. Meynard, H. Foch, and G. Gateau, \"Comparative study of multilevel topologies: NPC, multicell inverter and SMC with IGBT.\" pp. 828-833 vol.1. [58] S. Bum-Seok, S. Gautam, M. D. Manjrekar, and T. A. Lipo, \"Multilevel Power Conversion - An Overview Of Topologies And Modulation Strategies.\" pp. AD-11-AD-24. [59] A. Nabae, I. Takahashi, and H. Akagi, “A New Neutral-Point-Clamped PWM Inverter,” Industry Applications, IEEE Transactions on, vol. IA-17, no. 5, pp. 518-523, 1981. [60] J. Rodriguez, S. Bernet, W. Bin, J. O. Pontt, and S. Kouro, “Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives,” Industrial Electronics, IEEE Transactions on, vol. 54, no. 6, pp. 2930-2945, 2007. [61] M. Fracchia, T. Ghiara, M. Marchesoni, and M. Mazzucchelli, \"Optimized modulation techniques for the generalized <e1>N</e1>-level converter.\" pp. 1205-1213 vol.2. [62] A. Damiano, M. Marchesoni, I. Marongiu, and A. Taffone, \"Optimization of harmonic performances in multilevel converter structures.\" pp. 341-346 vol.2. [63] Y. Xiaoming, and I. Barbi, “Fundamentals of a new diode clamping multilevel inverter,” IEEE Transactions on Power Electronics, vol. 15, no. 4, pp. 711-718, 2000. [64] S. Busquets-Monge, S. Alepuz, J. Bordonau, and J. Peracaula, “Voltage Balancing Control of Diode-Clamped Multilevel Converters With Passive Front-Ends,” IEEE Transactions on Power Electronics, vol. 23, no. 4, pp. 1751-1758, 2008. [65] J. Pou, R. Pindado, and D. Boroyevich, “Voltage-balance limits in four-level diode-clamped converters with passive front ends,” IEEE Transactions on Industrial Electronics, vol. 52, no. 1, pp. 190-196, 2005. [66] M. Marchesoni, and L. Vaccaro, \"Operating limits in multilevel MPC inverters with active front ends.\" pp. 192-197. [67] W. Mcmurray, \"Fast response stepped-wave switching power converter circuit,\" Google Patents, 1971. [68] P. W. Hammond, \"A new approach to enhance power quality for medium voltage drives.\" pp. 231-235. [69] A. Lesnicar, and R. Marquardt, \"An innovative modular multilevel converter topology suitable for a wide power range.\" p. 6 pp. Vol. 3. [70] R. Marquardt, and A. Lesnicar, \"A new modular voltage source inverter topology.\" pp. 0-50. [71] M. Hagiwara, R. Maeda, and H. Akagi, “Negative-sequence reactive-power control by a PWM STATCOM based on a modular multilevel cascade converter (MMCC-SDBC),” Industry Applications, IEEE Transactions on, vol. 48, no. 2, pp. 720-729, 2012. [72] J. I. Y. Ota, Y. Shibano, and H. Akagi, “A Phase-Shifted PWM D-STATCOM Using a Modular Multilevel Cascade Converter (SSBC)&#x2014;Part II: Zero-Voltage-Ride-Through Capability,” IEEE Transactions on Industry Applications, vol. 51, no. 1, pp. 289-296, 2015. [73] C. t. Lee, B. s. Wang, S. w. Chen, S. f. Chou, J. l. Huang, P. t. Cheng, H. Akagi, and P. Barbosa, “Average Power Balancing Control of a STATCOM Based on the Cascaded H-Bridge PWM Converter With Star Configuration,” IEEE Transactions on Industry Applications, vol. 50, no. 6, pp. 3893-3901, 2014. [74] L. Jih-Sheng, and P. Fang Zheng, \"Multilevel converters-a new breed of power converters.\" pp. 2348-2356 vol.3. [75] H. Akagi, “Classification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC),” Power Electronics, IEEE Transactions on, vol. 26, no. 11, pp. 3119-3130, 2011. [76] B. Gultekin, and M. Ermis, “Cascaded Multilevel Converter-Based Transmission STATCOM: System Design Methodology and Development of a 12 kV &#x00B1;12 MVAr Power Stage,” IEEE Transactions on Power Electronics, vol. 28, no. 11, pp. 4930-4950, 2013. [77] C. Nwobu, I. Efika, O. Oghorada, and L. Zhang, \"A modular multilevel flying capacitor converter-based STATCOM for reactive power control in distribution systems.\" pp. 1-9. [78] H. Akagi, S. Inoue, and T. Yoshii, “Control and performance of a transformerless cascade PWM STATCOM with star configuration,” Industry Applications, IEEE Transactions on, vol. 43, no. 4, pp. 1041-1049, 2007. [79] K. Sano, and M. Takasaki, “A Transformerless D-STATCOM Based on a Multivoltage Cascade Converter Requiring No DC Sources,” IEEE Transactions on Power Electronics, vol. 27, no. 6, pp. 2783-2795, 2012. [80] M. Hagiwara, R. Maeda, and H. Akagi, “Application of a Modular Multilevel Cascade Converter (MMCC-SDBC) to a STATCOM,” IEEJ Transactions on Industry Applications, vol. 131, pp. 1433-1441, 2011. [81] M. Karimi-Ghartemani, and M. R. Iravani, “A method for synchronization of power electronic converters in polluted and variable-frequency environments,” IEEE Transactions on Power Systems, vol. 19, no. 3, pp. 1263-1270, 2004. [82] A. Timbus, M. Liserre, R. Teodorescu, and F. Blaabjerg, \"Synchronization methods for three phase distributed power generation systems - An overview and evaluation.\" pp. 2474-2481. [83] J. Svensson, “Synchronisation methods for grid-connected voltage source converters,” IEE Proceedings - Generation, Transmission and Distribution, vol. 148, no. 3, pp. 229-235, 2001. [84] R. Cardoso, R. F. D. Camargo, H. Pinheiro, and H. A. Grundling, “Kalman filter based synchronisation methods,” IET Generation, Transmission & Distribution, vol. 2, no. 4, pp. 542-555, 2008. [85] V. M. Moreno, M. Liserre, A. Pigazo, and A. Dell'Aquila, “A Comparative Analysis of Real-Time Algorithms for Power Signal Decomposition in Multiple Synchronous Reference Frames,” IEEE Transactions on Power Electronics, vol. 22, no. 4, pp. 1280-1289, 2007. [86] M. S. Padua, S. M. Deckmann, G. S. Sperandio, F. P. Marafao, and D. Colon, \"Comparative analysis of Synchronization Algorithms based on PLL, RDFT and Kalman Filter.\" pp. 964-970. [87] A. A. Girgis, W. B. Chang, and E. B. Makram, “A digital recursive measurement scheme for online tracking of power system harmonics,” IEEE Transactions on Power Delivery, vol. 6, no. 3, pp. 1153-1160, 1991. [88] S. Hong-Seok, P. Hyun-Gyu, and N. Kwanghee, \"An instantaneous phase angle detection algorithm under unbalanced line voltage condition.\" pp. 533-537 vol.1. [89] J. Nwobu, A. Nakiganda, and L. Zhang, “Grid Voltage Synchronization for Unbalanced Voltages Using the Energy Operator,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. PP, no. 99, pp. 1-1, 2017. [90] F. Baradarani, M. R. D. Zadeh, and M. A. Zamani, “A Phase-Angle Estimation Method for Synchronization of Grid-Connected Power-Electronic Converters,” IEEE Transactions on Power Delivery, vol. 30, no. 2, pp. 827-835, 2015. [91] B. P. McGrath, D. G. Holmes, and J. J. H. Galloway, “Power converter line synchronization using a discrete Fourier transform (DFT) based on a variable sample rate,” IEEE Transactions on Power Electronics, vol. 20, no. 4, pp. 877-884, 2005. [92] T. Funaki, and S. Tanaka, \"Error estimation and correction of DFT in synchronized phasor measurement.\" pp. 448-453 vol.1. [93] T. Remus, L. Marco, and R. g. Pedro, \"Grid Synchronization in ThreePhase Power Converters,\" Grid Converters for Photovoltaic and Wind Power Systems, pp. 169-204: Wiley-IEEE Press, 2011. [94] G. Saccomando, and J. Svensson, \"Transient operation of grid-connected voltage source converter under unbalanced voltage conditions.\" pp. 2419-2424 vol.4. [95] A. Nicastri, and A. Nagliero, \"Comparison and evaluation of the PLL techniques for the design of the grid-connected inverter systems.\" pp. 3865-3870. [96] E. Robles, S. Ceballos, J. Pou, J. L. Martín, J. Zaragoza, and P. Ibañez, “Variable-Frequency Grid-Sequence Detector Based on a Quasi-Ideal Low-Pass Filter Stage and a Phase-Locked Loop,” IEEE Transactions on Power Electronics, vol. 25, no. 10, pp. 2552-2563, 2010. [97] E. Courbon, S. Poullain, and J. Thomas, \"Analysis and synthesis of a digital high dynamics robust PLL for VSC-HVDC robust control.\" [98] L. Shi, and M. L. Crow, \"A novel PLL system based on adaptive resonant filter.\" pp. 1-8. [99] S. Yongsug, and T. A. Lipo, “Control scheme in hybrid synchronous stationary frame for PWM AC/DC converter under generalized unbalanced operating conditions,” IEEE Transactions on Industry Applications, vol. 42, no. 3, pp. 825-835, 2006. [100] S. Yongsug, V. Tijeras, and T. A. Lipo, \"A control method in dq synchronous frame for PWM boost rectifier under generalized unbalanced operating conditions.\" pp. 1425-1430 vol.3. [101] S. Hong-Seok, and N. Kwanghee, “Dual current control scheme for PWM converter under unbalanced input voltage conditions,” IEEE Transactions on Industrial Electronics, vol. 46, no. 5, pp. 953-959, 1999. [102] A. V. Stankovic, and T. A. Lipo, “A novel control method for input output harmonic elimination of the PWM boost type rectifier under unbalanced operating conditions,” IEEE Transactions on Power Electronics, vol. 16, no. 5, pp. 603-611, 2001. [103] L. A. Serpa, S. Ponnaluri, P. M. Barbosa, and J. W. Kolar, “A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverters to the Grid Through LCL Filters,” IEEE Transactions on Industry Applications, vol. 43, no. 5, pp. 1388-1400, 2007. [104] P. CortÉs, J. RodrÍguez, P. Antoniewicz, and M. Kazmierkowski, “Direct Power Control of an AFE Using Predictive Control,” IEEE Transactions on Power Electronics, vol. 23, no. 5, pp. 2516-2523, 2008. [105] T. Remus, L. Marco, and R. g. Pedro, \"Control of Grid Converters under Grid Faults,\" Grid Converters for Photovoltaic and Wind Power Systems, pp. 237-287: Wiley-IEEE Press, 2011. [106] D. J. Hanson, C. Horwill, B. D. Gemmell, and D. R. Monkhouse, \"A STATCOM-based relocatable SVC project in the UK for National Grid.\" pp. 532-537 vol.1. [107] G. Reed, J. Paserba, T. Croasdaile, R. Westover, S. Jochi, N. Morishima, M. Takeda, T. Sugiyama, Y. Hamasaki, T. Snow, and A. Abed, \"SDG&E Talega STATCOM project-system analysis, design, and configuration.\" pp. 1393-1398 vol.2. [108] Y. Qingguang, L. Pei, L. Wenhua, and X. Xiaorong, \"Overview of STATCOM technologies.\" pp. 647-652 Vol.2. [109] ABB, “SVC Light Reference List - Examples of Projects.” [110] C. Junling, Y. Zhizhu, W. Ping, and L. Yaohua, \"Capacitor voltage balancing control of cascaded multilevel inverter for high-power active power filters.\" pp. 1683-1687. [111] P. Münch, D. Görges, M. Izák, and S. Liu, \"Integrated current control, energy control and energy balancing of modular multilevel converters.\" pp. 150-155. [112] D. Siemaszko, A. Antonopoulos, K. Ilves, M. Vasiladiotis, L. Angquist, and H.-P. Nee, \"Evaluation of control and modulation methods for modular multilevel converters.\" pp. 746-753. [113] A. Dekka, B. Wu, N. R. Zargari, and R. L. Fuentes, “Dynamic Voltage Balancing Algorithm for Modular Multilevel Converter: A Unique Solution,” IEEE Transactions on Power Electronics, vol. 31, no. 2, pp. 952-963, 2016. [114] X. She, A. Q. Huang, and G. Wang, “3-D Space Modulation With Voltage Balancing Capability for a Cascaded Seven-Level Converter in a Solid-State Transformer,” IEEE Transactions on Power Electronics, vol. 26, no. 12, pp. 3778-3789, 2011. [115] O. J. K. Oghorada, C. J. Nwobu, and L. Zhang, \"Control of a single-star flying capacitor converter modular multi-level cascaded converter (SSFCC-MMCC) STATCOM for unbalanced load compensation.\" pp. 1-6. [116] O. J. K. Oghorada, and L. Zhang, \"Control of a Modular Multi-level Converter STATCOM for low voltage ride-through condition.\" pp. 3691-3696. [117] R. E. Betz, T. Summers, and T. Furney, \"Symmetry Compensation using a H-Bridge Multilevel STATCOM with Zero Sequence Injection.\" pp. 1724-1731. [118] T. J. Summers, R. E. Betz, and G. Mirzaeva, \"Phase leg voltage balancing of a cascaded H-Bridge converter based STATCOM using zero sequence injection.\" pp. 1-10. [119] N. Hatano, and T. Ise, “Control Scheme of Cascaded H-Bridge STATCOM Using Zero-Sequence Voltage and Negative-Sequence Current,” Power Delivery, IEEE Transactions on, vol. 25, no. 2, pp. 543-550, 2010. [120] P. Sochor, and H. Akagi, “Theoretical Comparison in Energy-Balancing Capability Between Star- and Delta-Configured Modular Multilevel Cascade Inverters for Utility-Scale Photovoltaic Systems,” Power Electronics, IEEE Transactions on, vol. 31, no. 3, pp. 1980-1992, 2016. [121] Y. Yifan, G. Konstantinou, B. Hredzak, and V. G. Agelidis, “Power Balance Optimization of Cascaded H-Bridge Multilevel Converters for Large-Scale Photovoltaic Integration,” Power Electronics, IEEE Transactions on, vol. 31, no. 2, pp. 1108-1120, 2016. [122] Y. Yu, G. Konstantinou, B. Hredzak, and V. G. Agelidis, “Power balance of cascaded H-bridge multilevel converters for large-scale photovoltaic integration,” IEEE Transactions on Power Electronics, vol. 31, no. 1, pp. 292-303, 2016. [123] b. e, and M. Bongiorno, “Investigation of Negative-Sequence Injection Capability of Cascaded H-Bridge Converters in Star and Delta Configuration,” IEEE Transactions on Power Electronics, vol. PP, no. 99, pp. 1-1, 2016. [124] E. Solas, G. Abad, J. A. Barrena, S. Aurtenetxea, A. Cárcar, and L. Zając, “Modular Multilevel Converter With Different Submodule Concepts&#x2014;Part I: Capacitor Voltage Balancing Method,” IEEE Transactions on Industrial Electronics, vol. 60, no. 10, pp. 4525-4535, 2013. [125] E. Solas, G. Abad, J. A. Barrena, S. Aurtenetxea, A. Cárcar, and L. Zając, “Modular Multilevel Converter With Different Submodule Concepts&#x2014;Part II: Experimental Validation and Comparison for HVDC Application,” IEEE Transactions on Industrial Electronics, vol. 60, no. 10, pp. 4536-4545, 2013. [126] I. B. Efika, “A Multi-level Multi-Modular Flying Capacitor Voltage Source Converter for High Power Applications,” University of Leeds, 2015. [127] I. B. Efika, “A Multi-level Multi-Modular Flying Capacitor Voltage Source Converter for High Power Applications,” University of Leeds, 2015. [128] S. Bifaretti, P. Zanchetta, F. Yue, F. Iov, and J. Clare, \"Power flow control through a multi-level H-bridge based power converter for Universal and Flexible Power Management in future electrical grids.\" pp. 1771-1778. [129] L. Maharjan, S. Inoue, H. Akagi, and J. Asakura, “State-of-charge (SOC)-balancing control of a battery energy storage system based on a cascade PWM converter,” Power Electronics, IEEE Transactions on, vol. 24, no. 6, pp. 1628-1636, 2009. [130] L. Maharjan, S. Inoue, and H. Akagi, “A transformerless energy storage system based on a cascade multilevel PWM converter with star configuration,” Industry Applications, IEEE Transactions on, vol. 44, no. 5, pp. 1621-1630, 2008. [131] S. Rajasekar, and R. Gupta, \"Solar photovoltaic power conversion using modular multilevel converter.\" pp. 1-6. [132] R. Feldman, A. Watson, J. Clare, P. Wheeler, D. Trainer, and R. Crookes, “DC fault ride-through capability and STATCOM operation of a hybrid voltage source converter arrangement for HVDC power transmission and reactive power compensation,” 2012. [133] X. She, and A. Huang, \"Circulating current control of double-star chopper-cell modular multilevel converter for HVDC system.\" pp. 1234-1239. [134] X. She, A. Huang, X. Ni, and R. Burgos, \"AC circulating currents suppression in modular multilevel converter.\" pp. 191-196. [135] J. Soderstrom, It's time to connect-Technical description of HVDC Light technology, Ludvika, Sweden: ABB AB Grid Systems-HVDC, 2005. [136] T. Lüth, M. M. C. Merlin, T. C. Green, F. Hassan, and C. D. Barker, “High-Frequency Operation of a DC/AC/DC System for HVDC Applications,” IEEE Transactions on Power Electronics, vol. 29, no. 8, pp. 4107-4115, 2014. [137] T. Lüth, M. M. C. Merlin, T. C. Green, C. D. Barker, F. Hassan, R. W. Critchley, R. W. Crookes, D. Trainer, and K. Dyke, \"Choice of AC operating voltage in HV DC/AC/DC system.\" pp. 1-5. [138] T. Lüth, M. M. C. Merlin, T. C. Green, C. D. Barker, F. Hassan, R. W. Critchley, R. W. Crookes, and K. Dyke, \"Performance of a DC/AC/DC VSC system to interconnect HVDC systems.\" pp. 1-6. [139] E. M. Farr, R. Feldman, A. J. Watson, R. P. Burgos, J. C. Clare, P. W. Wheeler, and D. Boroyevich, \"Alternate Arm Converter (AAC) operation under faulted AC-grid conditions.\" pp. 1-6. [140] M. M. Merlin, T. C. Green, P. D. Mitcheson, D. R. Trainer, R. Critchley, W. Crookes, and F. Hassan, “The Alternate Arm Converter: A New Hybrid Multilevel Converter With DC-Fault Blocking Capability,” 2014. [141] F. J. Moreno, M. M. C. Merlin, D. R. Trainer, T. C. Green, and K. J. Dyke, \"Zero phase sequence voltage injection for the alternate arm converter.\" pp. 1-6. [142] E. Amankwah, A. Watson, R. Feldman, J. Clare, and P. Wheeler, \"Experimental validation of a parallel hybrid modular multilevel voltage source converter for HVDC transmission.\" pp. 1607-1614. [143] R. Feldman, M. Tomasini, J. C. Clare, P. Wheeler, D. R. Trainer, and R. S. Whitehouse, \"A hybrid voltage source converter arrangement for HVDC power transmission and reactive power compensation.\" pp. 1-6. [144] A. Grid, “HVDC-VSC transmission technology of the future,” Alstom Grid, vol. 1, pp. 13-17, 2011. [145] C. Barker, \"HVDC for Beginners and Beyond,\" AREVA T&D publication, 2009. [146] M. Davies, M. Dommaschk, J. Dorn, J. Lang, D. Retzmann, and D. Soerangr, \"HVDC PLUS–Basics and principle of operation.\" [147] C. B. C. Oates, and D. Trainer, “VSC HVDC Converter Operation,” vol. ed. PEMD 2014, April 2014. [148] N. MacLeod, C. Davidson, and N. Kirby, \"A multi-level topology for Voltage Source Converter (VSC) HVDC transmission projects.\" [149] C. Oates, and C. Davidson, \"A comparison of two methods of estimating losses in the Modular Multi-Level Converter.\" pp. 1-10. [150] S. S. Fazel, S. Bernet, D. Krug, and K. Jalili, “Design and comparison of 4-kV neutral-point-clamped, flying-capacitor, and series-connected H-bridge multilevel converters,” IEEE Transactions on Industry Applications, vol. 43, no. 4, pp. 1032-1040, 2007. [151] A. K. Sadigh, V. Dargahi, and K. A. Corzine, “Analytical determination of conduction and switching power losses in flying-capacitor-based active neutral-point-clamped multilevel converter,” IEEE Transactions on Power Electronics, vol. 31, no. 8, pp. 5473-5494, 2016. [152] J. Li, X. Zhao, Q. Song, H. Rao, S. Xu, and M. Chen, \"Loss calculation method and loss characteristic analysis of MMC based VSC-HVDC system.\" pp. 1-6. [153] P. S. Jones, and C. C. Davidson, \"Calculation of power losses for MMC-based VSC HVDC stations.\" pp. 1-10. [154] P. S. Jones, and C. Davidson, \"Calculation of power losses for MMC-based VSC HVDC stations.\" pp. 1-10. [155] O. J. K. Oghorada, and L. Zhang, \"Performance evaluation of pulse width modulation techniques for losses reduction in modular multilevel flying capacitor converter.\" pp. 1-6. [156] F. Krismer, and J. W. Kolar, “Closed form solution for minimum conduction loss modulation of DAB converters,” IEEE Transactions on Power Electronics, vol. 27, no. 1, pp. 174-188, 2012. [157] L. Schwager, A. Tuysuz, C. Zwyssig, and J. W. Kolar, “Modeling and comparison of machine and converter losses for PWM and PAM in high-speed drives,” IEEE Transactions on Industry Applications, vol. 50, no. 2, pp. 995-1006, 2014. [158] S. Rohner, S. Bernet, M. Hiller, and R. Sommer, “Modulation, losses, and semiconductor requirements of modular multilevel converters,” Industrial Electronics, IEEE Transactions on, vol. 57, no. 8, pp. 2633-2642, 2010. [159] Q. Tu, and Z. Xu, \"Power losses evaluation for modular multilevel converter with junction temperature feedback.\" pp. 1-7. [160] D. Andler, R. Alvarez, S. Bernet, and J. Rodriguez, “Switching loss analysis of 4.5-kV–5.5-kA IGCTs within a 3L-ANPC phase leg prototype,” IEEE Transactions on Industry Applications, vol. 50, no. 1, pp. 584-592, 2014. [161] M. Schweizer, and J. W. Kolar, “Design and implementation of a highly efficient three-level T-type converter for low-voltage applications,” IEEE Transactions on Power Electronics, vol. 28, no. 2, pp. 899-907, 2013. [162] M. Hartmann, H. Ertl, and J. W. Kolar, “Current control of three-phase rectifier systems using three independent current controllers,” IEEE Transactions on Power electronics, vol. 28, no. 8, pp. 3988-4000, 2013. [163] M. A. Boost, and P. D. Ziogas, “State-of-the-art carrier PWM techniques: A critical evaluation,” Industry Applications, IEEE Transactions on, vol. 24, no. 2, pp. 271-280, 1988. [164] B. Velaerts, P. Mathys, E. Tatakis, and G. Bingen, \"A novel approach to the generation and optimization of three-level PWM wave forms for induction motor inverters.\" pp. 1255-1262. [165] D. G. Holmes, and T. A. Lipo, Pulse width modulation for power converters: principles and practice: John Wiley & Sons, 2003. [166] A. Massoud, S. Finney, and B. Williams, \"Control techniques for multilevel voltage source inverters.\" pp. 171-176. [167] J. Zubek, A. Abbondanti, and C. J. Norby, “Pulsewidth modulated inverter motor drives with improved modulation,” Industry Applications, IEEE Transactions on, no. 6, pp. 695-703, 1975. [168] A. M. Massoud, S. J. Finney, and B. W. Williams, \"Conduction loss calculation for multilevel inverter: a generalized approach for carrier-based PWM technique.\" pp. 226-230 Vol.1. [169] A. Massoud, S. Finney, and B. Williams, “High-power, high-voltage IGBT applications: series connection of IGBTs or multilevel converters?,” International journal of electronics, vol. 90, no. 11-12, pp. 763-778, 2003. [170] V. R. Stefanovic, and S. N. Vukosavic, \"Space-vector PWM voltage control with optimized switching strategy.\" pp. 1025-1033. [171] D. Peng, F. C. Lee, and D. Boroyevich, \"A novel SVM algorithm for multilevel three-phase converters.\" pp. 509-513. [172] J. H. Seo, C. H. Choi, and D.-S. Hyun, “A new simplified space-vector PWM method for three-level inverters,” Power Electronics, IEEE Transactions on, vol. 16, no. 4, pp. 545-550, 2001. [173] G. Brando, A. Dannier, A. Del Pizzo, and D. Iannuzzi, \"A SVM technique with homopolar voltage control in m-level multi modular converters.\" pp. 1531-1537. [174] I. Ahmed, V. B. Borghate, A. Matsa, P. M. Meshram, H. M. Suryawanshi, and M. A. Chaudhari, “Simplified space vector modulation techniques for multilevel inverters,” IEEE Transactions on Power Electronics, vol. 31, no. 12, pp. 8483-8499, 2016. [175] S. J. Watkins, and L. Zhang, \"Multilevel space vector PWM control schemes for a flying-capacitor inverter.\" pp. 12-17 Vol.1. [176] Z. B. Ibrahim, M. L. Hossain, M. N. Talib, R. Mustafa, and N. M. N. Mahadi, \"A five level cascaded H-bridge inverter based on space vector pulse width modulation technique.\" pp. 293-297. [177] S. Watkins, and L. Zhang, \"Multilevel space vector pwm control schemes for a flying-capacitor inverter.\" pp. 12-17. [178] A. Trentin, P. Zanchetta, and P. Wheeler, \"A New Investigation on Space Vector Modulation Technique for Voltage Source Inverter in AC Drive.\" pp. 1627-1632. [179] A. Trentin, P. Zanchetta, P. Wheeler, J. Clare, R. Wood, and W. Typton, \"Performance Assessment of SVM Modulation Techniques for Losses Reduction in Induction Motor Drives.\" pp. 1031-1037. [180] S. T. Joshi, A. Haneesh, G. Narayanan, and V. Ranganathan, “A computationally efficient PWM algorithm for multilevel inverters,” 2003. [181] Y.-H. Lee, B.-S. Suh, and D.-S. Hyun, “A novel PWM scheme for a three-level voltage source inverter with GTO thyristors,” Industry Applications, IEEE Transactions on, vol. 32, no. 2, pp. 260-268, 1996. [182] Y. Deng, K. H. Teo, C. Duan, T. G. Habetler, and R. G. Harley, “A fast and generalized space vector modulation scheme for multilevel inverters,” IEEE Transactions on Power Electronics, vol. 29, no. 10, pp. 5204-5217, 2014. [183] I. B. Efika, L. Zhang, A. Watson, and J. Clare, \"An overlapping multi-hexagon space vector modulation scheme for modular multilevel cascade converters.\" pp. 1-11. [184] S. Digital, “eZdsp F28335 Technical Reference,” Spectrum Digital Incorporated, 2007. [185] R. Duma, P. Dobra, M. Abrudean, and M. Dobra, \"Rapid prototyping of control systems using embedded target for TI C2000 DSP.\" pp. 1-5. [186] “IEEE Application Guide for IEEE Std 1547(TM), IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems,” IEEE Std 1547.2-2008, pp. 1-217, 2009. [187] “IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems - Amendment 1,” IEEE Std 1547a-2014 (Amendment to IEEE Std 1547-2003), pp. 1-16, 2014. [188] J. Bjorn, K. Patrik, A. Gunnar, H. Lennart, J. Tomas, and A. Sweden, “VSC-HVDC transmission with cascaded two-level converters,” 2011. [189] J. Peralta, H. Saad, S. Dennetiere, J. Mahseredjian, and S. Nguefeu, “Detailed and Averaged Models for a 401-Level MMC&#x2013;HVDC System,” IEEE Transactions on Power Delivery, vol. 27, no. 3, pp. 1501-1508, 2012. [190] M. S. Suleiman, A. A.-S. Mohammad, I. O. Georgios, and H. Babar, \"DC-Link Capacitor Current and Sizing in NPC and CHB Inverters,\" Power Electronic Converters for Microgrids, p. 352: Wiley-IEEE Press, 2014. [191] C. D. Townsend, T. J. Summers, J. Vodden, A. J. Watson, R. E. Betz, and J. C. Clare, “Optimization of Switching Losses and Capacitor Voltage Ripple Using Model Predictive Control of a Cascaded H-Bridge Multilevel StatCom,” IEEE Transactions on Power Electronics, vol. 28, no. 7, pp. 3077-3087, 2013. [192] G. Farivar, B. Hredzak, and V. G. Agelidis, “Reduced-Capacitance Thin-Film H-Bridge Multilevel STATCOM Control Utilizing an Analytic Filtering Scheme,” IEEE Transactions on Industrial Electronics, vol. 62, no. 10, pp. 6457-6468, 2015. [193] C. D. Townsend, Y. Yu, G. Konstantinou, and V. G. Agelidis, “Cascaded H-Bridge Multilevel PV Topology for Alleviation of Per-Phase Power Imbalances and Reduction of Second Harmonic Voltage Ripple,” IEEE Transactions on Power Electronics, vol. 31, no. 8, pp. 5574-5586, 2016. [194] G. Farivar, C. Townsend, B. Hredzak, J. Pou, and V. Agelidis, “A Low Capacitance Cascaded H-Bridge Multi-Level StatCom.” [195] M. J. Waite, “Active power filter for unbalanced distribution networks using a flying-capacitor multi-level inverter,” University of Leeds, 2011. [196] “HFBR-0501 Series Datasheet,” ed: Avago Technologies. [197] “Voltage Transducer LV 25-P,” ed: LEM. [198] “Current Transducer LA 55-P,” ed: LEM. [199] H. Akagi, E. H. Watanabe, and M. Aredes, Instantaneous power theory and applications to power conditioning: John Wiley & Sons, 2007."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.727190"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/18372/1/Oghorada%20Ogaga%20Electronic%20and%20Electrical%20Engineering_PhD_2017%20Final%20Version.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Voltage and current unbalance are major problems in distribution networks, particularly with the integration of distributed generation systems. One way of mitigating these issues is by injecting negative sequence current into the distribution network using a Static Synchronous Compensator (STATCOM) which normally also regulates the voltage and power factor. The benefits of modularity and scalability offered by Modular Multilevel Cascaded Converters (MMCC) make them suitable for STATCOM application. A number of different types of MMCC may be used, classified according to the sub-module circuit topology used. Their performance features and operational ranges for unbalanced load compensation are evaluated and quantified in this research. This thesis investigates the use of both single star and single delta configured five-level Flying Capacitor (FC) converter MMCC based STATCOMs for unbalanced load compensation. A detailed study is carried out to compare this type of sub-module with several other types namely: half bridge, 3-L H-bridge and 3-L FC half bridge, and reveals the one best suited to STATCOM operation. With the choice of 5-L FC H-bridge as the sub-module for STATCOM operation, a detailed investigation is also performed to decide which pulse width modulation technique is the best. This was based on the assessment of total harmonic distortion, power loss, sub-module switch utilization and natural balancing of inner flying capacitors. Two new modulation techniques of swapped-carrier PWM (SC-PWM) along with phase disposed and phase shifted PWM (PS-PWM) are analyzed under these four performance metrics. A novel contribution of this research is the development of a new space vector modulation technique using an overlapping hexagon technique. This space vector strategy offers benefits of eliminating control complexity and improving waveform quality, unlike the case of multilevel space vector technique. The simulation and experimental results show that this method provides superior performance and is applicable for other MMCC sub-modules. Another contribution is the analysis and quantification of operating ranges of both single star and delta MMCCs in rating the cluster dc-link voltage (star) and current (delta) for unbalanced load compensation. A novel method of extending the operating capabilities of both configurations uses a third harmonic injection method. An experimental investigation validates the operating range extension compared to the pure sinusoidal zero sequence voltage and current injection. Also, the superiority of the single delta configured MMCC for unbalanced loading compensation is validated."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Modular Multilevel Cascaded Flying Capacitor STATCOM for Balanced and Unbalanced Load Compensation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhang, Li"],"dc:creator":["Oghorada, Oghenewvogaga"],"dc:date":["2017-08-17"],"dc:date.issued":["2017-08"],"dc:description.abstract":["Voltage and current unbalance are major problems in distribution networks, particularly with the integration of distributed generation systems. One way of mitigating these issues is by injecting negative sequence current into the distribution network using a Static Synchronous Compensator (STATCOM) which normally also regulates the voltage and power factor. The benefits of modularity and scalability offered by Modular Multilevel Cascaded Converters (MMCC) make them suitable for STATCOM application. A number of different types of MMCC may be used, classified according to the sub-module circuit topology used. Their performance features and operational ranges for unbalanced load compensation are evaluated and quantified in this research. This thesis investigates the use of both single star and single delta configured five-level Flying Capacitor (FC) converter MMCC based STATCOMs for unbalanced load compensation. A detailed study is carried out to compare this type of sub-module with several other types namely: half bridge, 3-L H-bridge and 3-L FC half bridge, and reveals the one best suited to STATCOM operation. With the choice of 5-L FC H-bridge as the sub-module for STATCOM operation, a detailed investigation is also performed to decide which pulse width modulation technique is the best. This was based on the assessment of total harmonic distortion, power loss, sub-module switch utilization and natural balancing of inner flying capacitors. Two new modulation techniques of swapped-carrier PWM (SC-PWM) along with phase disposed and phase shifted PWM (PS-PWM) are analyzed under these four performance metrics. A novel contribution of this research is the development of a new space vector modulation technique using an overlapping hexagon technique. This space vector strategy offers benefits of eliminating control complexity and improving waveform quality, unlike the case of multilevel space vector technique. The simulation and experimental results show that this method provides superior performance and is applicable for other MMCC sub-modules. Another contribution is the analysis and quantification of operating ranges of both single star and delta MMCCs in rating the cluster dc-link voltage (star) and current (delta) for unbalanced load compensation. A novel method of extending the operating capabilities of both configurations uses a third harmonic injection method. An experimental investigation validates the operating range extension compared to the pure sinusoidal zero sequence voltage and current injection. Also, the superiority of the single delta configured MMCC for unbalanced loading compensation is validated."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.727190"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/18372/1/Oghorada%20Ogaga%20Electronic%20and%20Electrical%20Engineering_PhD_2017%20Final%20Version.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Institute of Integrated Information Systems (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/18372/"],"dc:relation.references":["[1] H. C. Chen, and P. T. Cheng, “A DC Bus Voltage Balancing Technique for the Cascaded H-Bridge STATCOM With Improved Reliability Under Grid Faults,” IEEE Transactions on Industry Applications, vol. 53, no. 2, pp. 1263-1270, 2017. [2] L. Wang, C. H. Chang, B. L. Kuan, and A. V. Prokhorov, “Stability Improvement of a Two-Area Power System Connected With an Integrated Onshore and Offshore Wind Farm Using a STATCOM,” IEEE Transactions on Industry Applications, vol. 53, no. 2, pp. 867-877, 2017. [3] X. Liu, J. Lv, C. Gao, Z. Chen, and S. Chen, “A Novel STATCOM Based on Diode-Clamped Modular Multilevel Converters,” IEEE Transactions on Power Electronics, vol. 32, no. 8, pp. 5964-5977, 2017. [4] M. Moghbel, M. A. S. Masoum, A. Fereidouni, and S. Deilami, “Optimal Sizing, Siting and Operation of Custom Power Devices with STATCOM and APLC Functions for Real-Time Reactive Power and Network Voltage Quality Control of Smart Grid,” IEEE Transactions on Smart Grid, vol. PP, no. 99, pp. 1-1, 2017. [5] R. K. Varma, and R. Salehi, “SSR Mitigation With a New Control of PV Solar Farm as STATCOM (PV-STATCOM),” IEEE Transactions on Sustainable Energy, vol. PP, no. 99, pp. 1-1, 2017. [6] D. Lu, J. Wang, J. Yao, S. Wang, J. Zhu, H. Hu, and L. Zhang, “Clustered Voltage Balancing Mechanism and its Control Strategy for Star-Connected Cascaded H-Bridge STATCOM,” IEEE Transactions on Industrial Electronics, vol. PP, no. 99, pp. 1-1, 2017. [7] B. Lei, and S. Fei, “control for STATCOM to improve voltage stability of power system,” Electronics Letters, vol. 53, no. 10, pp. 670-672, 2017. [8] M. B. Shadmand, M. Mosa, R. S. Balog, and H. Abu-Rub, “Model Predictive Control of a Capacitorless Matrix Converter-Based STATCOM,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 5, no. 2, pp. 796-808, 2017. [9] Z. He, F. Ma, Q. Xu, Y. Chen, C. Li, M. Li, J. M. Guerrero, and A. Luo, “Reactive Power Strategy of Cascaded Delta-Connected STATCOM Under Asymmetrical Voltage Conditions,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. 5, no. 2, pp. 784-795, 2017. [10] G. Farivar, C. D. Townsend, B. Hredzak, J. Pou, and V. G. Agelidis, “Passive Reactor Compensated Cascaded H-Bridge Multilevel LC-StatCom,” IEEE Transactions on Power Electronics, vol. 32, no. 11, pp. 8338-8348, 2017. [11] J. Khodaparast, M. Khederzadeh, F. F. d. Silva, and C. L. Bak, “Variation of UPFC controllable parameters during power swing and their impacts on distance relay,” IET Generation, Transmission & Distribution, vol. 11, no. 7, pp. 1735-1744, 2017. [12] J. Khodaparast, M. Khederzadeh, F. F. d. Silva, and C. L. Bak, “Power Swing Detection in UPFC-Compensated Line by Phase Angle of Current,” IEEE Journal on Emerging and Selected Topics in Circuits and Systems, vol. PP, no. 99, pp. 1-10, 2017. [13] F. M. Albatsh, S. Mekhilef, S. Ahmad, and H. Mokhlis, “Fuzzy Logic Based UPFC and Laboratory Prototype Validation for Dynamic Power Flow Control in Transmission Lines,” IEEE Transactions on Industrial Electronics, vol. PP, no. 99, pp. 1-1, 2017. [14] P. Li, G. P. Adam, D. Holliday, S. J. Finney, and B. W. Williams, “Simulation study of FACTS devices based on AC&#8211;AC modular multilevel hexagonal chopper,” IET Power Electronics, vol. 10, no. 8, pp. 919-930, 2017. [15] M. Raza, E. Prieto-Araujo, and O. Gomis-Bellmunt, “Small Signal Stability Analysis of Offshore AC Network having Multiple VSC-HVDC System,” IEEE Transactions on Power Delivery, vol. PP, no. 99, pp. 1-1, 2017. [16] A. Raza, X. Dianguo, L. Yuchao, S. Xunwen, B. W. Williams, and C. Cecati, “Coordinated Operation and Control of VSC Based Multiterminal High Voltage DC Transmission Systems,” IEEE Transactions on Sustainable Energy, vol. 7, no. 1, pp. 364-373, 2016. [17] G. P. Adam, I. A. Gowaid, S. J. Finney, D. Holliday, and B. W. Williams, “Review of dc&#x2013;dc converters for multi-terminal HVDC transmission networks,” IET Power Electronics, vol. 9, no. 2, pp. 281-296, 2016. [18] G. P. Adam, and B. W. Williams, “Multi-pole voltage source converter HVDC transmission systems,” IET Generation, Transmission & Distribution, vol. 10, no. 2, pp. 496-507, 2016. [19] R. Li, L. Xu, L. Yao, and B. W. Williams, “Active Control of DC Fault Currents in DC Solid-State Transformers During Ride-Through Operation of Multi-Terminal HVDC Systems,” IEEE Transactions on Energy Conversion, vol. 31, no. 4, pp. 1336-1346, 2016. [20] R. Li, J. E. Fletcher, L. Xu, and B. W. Williams, “Enhanced Flat-Topped Modulation for MMC Control in HVDC Transmission Systems,” IEEE Transactions on Power Delivery, vol. 32, no. 1, pp. 152-161, 2017. [21] R. Li, J. E. Fletcher, and B. W. Williams, “Influence of third harmonic injection on modular multilevel converter -based high-voltage direct current transmission systems,” IET Generation, Transmission & Distribution, vol. 10, no. 11, pp. 2764-2770, 2016. [22] J. Wang, J. Liang, C. Wang, and X. Dong, “Circulating Current Suppression for MMC-HVDC under Unbalanced Grid Conditions,” IEEE Transactions on Industry Applications, vol. 53, no. 4, pp. 3250-3259, 2017. [23] H. Mahmoudi, M. Aleenejad, and R. Ahmadi, “Modulated Model Predictive Control of Modular Multilevel Converters in VSC-HVDC Systems,” IEEE Transactions on Power Delivery, vol. PP, no. 99, pp. 1-1, 2017. [24] S. M. Muyeen, and H. M. Hasanien, “Operation and control of HVDC stations using continuous mixed <italic>p</italic>-norm-based adaptive fuzzy technique,” IET Generation, Transmission & Distribution, vol. 11, no. 9, pp. 2275-2282, 2017. [25] X. Yang, Y. Xue, B. Chen, Z. Lin, T. Q. Zheng, and Y. Li, “Novel modular multilevel converter against DC faults for HVDC applications,” CSEE Journal of Power and Energy Systems, vol. 3, no. 2, pp. 140-149, 2017. [26] N. G. Hingorani, “High Power Electronics and flexible AC Transmission System,” IEEE Power Engineering Review, vol. 8, no. 7, pp. 3-4, 1988. [27] E. W. Kimbark, “Improvement of System Stability by Switched Series Capacitors,” IEEE Transactions on Power Apparatus and Systems, vol. PAS-85, no. 2, pp. 180-188, 1966. [28] A. Keri, “Improving transmission system performance using controlled series capacitors,” CIGRE, 1992. [29] ABB, “Available: http://new.abb.com/facts.” [30] Siemens, “Available: http://www.energy.siemens.com/hq/en/power-transmission/facts/.” [31] A. Edris, “Proposed terms and definitions for flexible AC transmission system (FACTS),” IEEE Transactions on Power Delivery, vol. 12, no. 4, pp. 1848-1853, 1997. [32] ABB, “A matter of FACTS - Deliver more high quality power,” 2015. [33] ALSTOM, “Flexible AC Transmission Systems: Solutions to Optimize Network Performance,” 2014. [34] A. SIEMENS, “Discover the World of FACTS Technology–Technical Compendium,” Power Transmission and Distribution, Erlangen, Germany, 2006. [35] C. J. Nwobu, “Control of a Modular Multilevel Flying Capacitor Based STATCOM for Distribution Systems,” University of Leeds, 2016. [36] F. J. Chivite-Zabalza, P. Izurza, G. Calvo, and M. A. Rodriguez, \"Laboratory tests of the voltage source converter for a 47 MVAR Series Static Synchronous Compensator for the Spanish high voltage transmission grid.\" pp. 1-6. [37] V. S. P. Cheung, H. S. H. Chung, K. W. Wang, and A. W. L. Lo, “Paralleling Multiple Static Synchronous Series Compensators Using Daisy-Chained Transformers,” IEEE Transactions on Power Electronics, vol. 29, no. 6, pp. 2764-2773, 2014. [38] M. Saradarzadeh, S. Farhangi, J. L. Schanen, P. O. Jeannin, and D. Frey, “Application of cascaded H-bridge distribution-static synchronous series compensator in electrical distribution system power flow control,” IET Power Electronics, vol. 5, no. 9, pp. 1660-1675, 2012. [39] C. Schauder, E. Stacey, M. Lund, L. Gyugyi, L. Kovalsky, A. Keri, A. Mehraban, and A. Edris, “AEP UPFC project: installation, commissioning and operation of the &plusmn;160 MVA STATCOM (phase I),” IEEE Transactions on Power Delivery, vol. 13, no. 4, pp. 1530-1535, 1998. [40] S. Y. Kim, J. S. Yoon, B. H. Chang, and D. H. Baek, \"The operation experience of KEPCO UPFC.\" pp. 2502-2505 Vol. 3. [41] Y. Sumi, Y. Harumoto, T. Hasegawa, M. Yano, K. Ikeda, and T. Matsuura, “New Static Var Control Using Force-Commutated Inverters,” IEEE Transactions on Power Apparatus and Systems, vol. PAS-100, no. 9, pp. 4216-4224, 1981. [42] K. Matsuno, I. Iyoda, and Y. Oue, \"An experience of FACTS development 1980s and 1990s.\" pp. 1378-1381 vol.2. [43] C. Schauder, M. Gernhardt, E. Stacey, T. Lemak, L. Gyugyi, T. W. Cease, and A. Edris, “Operation of &plusmn;100 MVAr TVA STATCON,” IEEE Transactions on Power Delivery, vol. 12, no. 4, pp. 1805-1811, 1997. [44] K. H. Sobtink, K. W. Renz, and H. Tyll, \"Operational experience and field tests of the SVG at Rejsby Hede.\" pp. 318-322 vol.1. [45] ABB, “Reference List,” 2015. [46] L. Gyugyi, “Dynamic compensation of AC transmission lines by solid-state synchronous voltage sources,” IEEE Transactions on Power Delivery, vol. 9, no. 2, pp. 904-911, 1994. [47] L. Gyugyi, “Unified power-flow control concept for flexible AC transmission systems,” IEE Proceedings C - Generation, Transmission and Distribution, vol. 139, no. 4, pp. 323-331, 1992. [48] L. Gyugyi, C. D. Schauder, and K. K. Sen, “Static Synchronous Series Compensator: A Solid-State Approach to the Series Compensation of Transmission Lines,” IEEE Power Engineering Review, vol. 17, no. 1, pp. 62-62, 1997. [49] S. Khomfoi, and L. M. Tolbert, “Multilevel power converters,” Power electronics handbook, pp. 451-482, 2007. [50] S. Kouro, M. Malinowski, K. Gopakumar, J. Pou, L. G. Franquelo, W. Bin, J. Rodriguez, M. A. Perez, and J. I. Leon, “Recent Advances and Industrial Applications of Multilevel Converters,” Industrial Electronics, IEEE Transactions on, vol. 57, no. 8, pp. 2553-2580, 2010. [51] L. Zhang, S. J. Watkins, and W. Shepherd, \"Analysis and control of a multi-level flying capacitor inverter.\" pp. 66-71. [52] L. Xu, and V. G. Agelidis, “Flying capacitor multilevel PWM converter based UPFC,” IEE Proceedings - Electric Power Applications, vol. 149, no. 4, pp. 304-310, 2002. [53] J. Rodriguez, L. Jih-Sheng, and P. Fang Zheng, “Multilevel inverters: a survey of topologies, controls, and applications,” IEEE Transactions on Industrial Electronics, vol. 49, no. 4, pp. 724-738, 2002. [54] T. Meynard, and H. Foch, \"Multi-level conversion: high voltage choppers and voltage-source inverters.\" pp. 397-403. [55] L. Jih-Sheng, and P. Fang Zheng, “Multilevel converters-a new breed of power converters,” IEEE Transactions on Industry Applications, vol. 32, no. 3, pp. 509-517, 1996. [56] M. L. Heldwein, S. A. Mussa, and I. Barbi, “Three-Phase Multilevel PWM Rectifiers Based on Conventional Bidirectional Converters,” IEEE Transactions on Power Electronics, vol. 25, no. 3, pp. 545-549, 2010. [57] L. Demas, T. A. Meynard, H. Foch, and G. Gateau, \"Comparative study of multilevel topologies: NPC, multicell inverter and SMC with IGBT.\" pp. 828-833 vol.1. [58] S. Bum-Seok, S. Gautam, M. D. Manjrekar, and T. A. Lipo, \"Multilevel Power Conversion - An Overview Of Topologies And Modulation Strategies.\" pp. AD-11-AD-24. [59] A. Nabae, I. Takahashi, and H. Akagi, “A New Neutral-Point-Clamped PWM Inverter,” Industry Applications, IEEE Transactions on, vol. IA-17, no. 5, pp. 518-523, 1981. [60] J. Rodriguez, S. Bernet, W. Bin, J. O. Pontt, and S. Kouro, “Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives,” Industrial Electronics, IEEE Transactions on, vol. 54, no. 6, pp. 2930-2945, 2007. [61] M. Fracchia, T. Ghiara, M. Marchesoni, and M. Mazzucchelli, \"Optimized modulation techniques for the generalized <e1>N</e1>-level converter.\" pp. 1205-1213 vol.2. [62] A. Damiano, M. Marchesoni, I. Marongiu, and A. Taffone, \"Optimization of harmonic performances in multilevel converter structures.\" pp. 341-346 vol.2. [63] Y. Xiaoming, and I. Barbi, “Fundamentals of a new diode clamping multilevel inverter,” IEEE Transactions on Power Electronics, vol. 15, no. 4, pp. 711-718, 2000. [64] S. Busquets-Monge, S. Alepuz, J. Bordonau, and J. Peracaula, “Voltage Balancing Control of Diode-Clamped Multilevel Converters With Passive Front-Ends,” IEEE Transactions on Power Electronics, vol. 23, no. 4, pp. 1751-1758, 2008. [65] J. Pou, R. Pindado, and D. Boroyevich, “Voltage-balance limits in four-level diode-clamped converters with passive front ends,” IEEE Transactions on Industrial Electronics, vol. 52, no. 1, pp. 190-196, 2005. [66] M. Marchesoni, and L. Vaccaro, \"Operating limits in multilevel MPC inverters with active front ends.\" pp. 192-197. [67] W. Mcmurray, \"Fast response stepped-wave switching power converter circuit,\" Google Patents, 1971. [68] P. W. Hammond, \"A new approach to enhance power quality for medium voltage drives.\" pp. 231-235. [69] A. Lesnicar, and R. Marquardt, \"An innovative modular multilevel converter topology suitable for a wide power range.\" p. 6 pp. Vol. 3. [70] R. Marquardt, and A. Lesnicar, \"A new modular voltage source inverter topology.\" pp. 0-50. [71] M. Hagiwara, R. Maeda, and H. Akagi, “Negative-sequence reactive-power control by a PWM STATCOM based on a modular multilevel cascade converter (MMCC-SDBC),” Industry Applications, IEEE Transactions on, vol. 48, no. 2, pp. 720-729, 2012. [72] J. I. Y. Ota, Y. Shibano, and H. Akagi, “A Phase-Shifted PWM D-STATCOM Using a Modular Multilevel Cascade Converter (SSBC)&#x2014;Part II: Zero-Voltage-Ride-Through Capability,” IEEE Transactions on Industry Applications, vol. 51, no. 1, pp. 289-296, 2015. [73] C. t. Lee, B. s. Wang, S. w. Chen, S. f. Chou, J. l. Huang, P. t. Cheng, H. Akagi, and P. Barbosa, “Average Power Balancing Control of a STATCOM Based on the Cascaded H-Bridge PWM Converter With Star Configuration,” IEEE Transactions on Industry Applications, vol. 50, no. 6, pp. 3893-3901, 2014. [74] L. Jih-Sheng, and P. Fang Zheng, \"Multilevel converters-a new breed of power converters.\" pp. 2348-2356 vol.3. [75] H. Akagi, “Classification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC),” Power Electronics, IEEE Transactions on, vol. 26, no. 11, pp. 3119-3130, 2011. [76] B. Gultekin, and M. Ermis, “Cascaded Multilevel Converter-Based Transmission STATCOM: System Design Methodology and Development of a 12 kV &#x00B1;12 MVAr Power Stage,” IEEE Transactions on Power Electronics, vol. 28, no. 11, pp. 4930-4950, 2013. [77] C. Nwobu, I. Efika, O. Oghorada, and L. Zhang, \"A modular multilevel flying capacitor converter-based STATCOM for reactive power control in distribution systems.\" pp. 1-9. [78] H. Akagi, S. Inoue, and T. Yoshii, “Control and performance of a transformerless cascade PWM STATCOM with star configuration,” Industry Applications, IEEE Transactions on, vol. 43, no. 4, pp. 1041-1049, 2007. [79] K. Sano, and M. Takasaki, “A Transformerless D-STATCOM Based on a Multivoltage Cascade Converter Requiring No DC Sources,” IEEE Transactions on Power Electronics, vol. 27, no. 6, pp. 2783-2795, 2012. [80] M. Hagiwara, R. Maeda, and H. Akagi, “Application of a Modular Multilevel Cascade Converter (MMCC-SDBC) to a STATCOM,” IEEJ Transactions on Industry Applications, vol. 131, pp. 1433-1441, 2011. [81] M. Karimi-Ghartemani, and M. R. Iravani, “A method for synchronization of power electronic converters in polluted and variable-frequency environments,” IEEE Transactions on Power Systems, vol. 19, no. 3, pp. 1263-1270, 2004. [82] A. Timbus, M. Liserre, R. Teodorescu, and F. Blaabjerg, \"Synchronization methods for three phase distributed power generation systems - An overview and evaluation.\" pp. 2474-2481. [83] J. Svensson, “Synchronisation methods for grid-connected voltage source converters,” IEE Proceedings - Generation, Transmission and Distribution, vol. 148, no. 3, pp. 229-235, 2001. [84] R. Cardoso, R. F. D. Camargo, H. Pinheiro, and H. A. Grundling, “Kalman filter based synchronisation methods,” IET Generation, Transmission & Distribution, vol. 2, no. 4, pp. 542-555, 2008. [85] V. M. Moreno, M. Liserre, A. Pigazo, and A. Dell'Aquila, “A Comparative Analysis of Real-Time Algorithms for Power Signal Decomposition in Multiple Synchronous Reference Frames,” IEEE Transactions on Power Electronics, vol. 22, no. 4, pp. 1280-1289, 2007. [86] M. S. Padua, S. M. Deckmann, G. S. Sperandio, F. P. Marafao, and D. Colon, \"Comparative analysis of Synchronization Algorithms based on PLL, RDFT and Kalman Filter.\" pp. 964-970. [87] A. A. Girgis, W. B. Chang, and E. B. Makram, “A digital recursive measurement scheme for online tracking of power system harmonics,” IEEE Transactions on Power Delivery, vol. 6, no. 3, pp. 1153-1160, 1991. [88] S. Hong-Seok, P. Hyun-Gyu, and N. Kwanghee, \"An instantaneous phase angle detection algorithm under unbalanced line voltage condition.\" pp. 533-537 vol.1. [89] J. Nwobu, A. Nakiganda, and L. Zhang, “Grid Voltage Synchronization for Unbalanced Voltages Using the Energy Operator,” IEEE Journal of Emerging and Selected Topics in Power Electronics, vol. PP, no. 99, pp. 1-1, 2017. [90] F. Baradarani, M. R. D. Zadeh, and M. A. Zamani, “A Phase-Angle Estimation Method for Synchronization of Grid-Connected Power-Electronic Converters,” IEEE Transactions on Power Delivery, vol. 30, no. 2, pp. 827-835, 2015. [91] B. P. McGrath, D. G. Holmes, and J. J. H. Galloway, “Power converter line synchronization using a discrete Fourier transform (DFT) based on a variable sample rate,” IEEE Transactions on Power Electronics, vol. 20, no. 4, pp. 877-884, 2005. [92] T. Funaki, and S. Tanaka, \"Error estimation and correction of DFT in synchronized phasor measurement.\" pp. 448-453 vol.1. [93] T. Remus, L. Marco, and R. g. Pedro, \"Grid Synchronization in ThreePhase Power Converters,\" Grid Converters for Photovoltaic and Wind Power Systems, pp. 169-204: Wiley-IEEE Press, 2011. [94] G. Saccomando, and J. Svensson, \"Transient operation of grid-connected voltage source converter under unbalanced voltage conditions.\" pp. 2419-2424 vol.4. [95] A. Nicastri, and A. Nagliero, \"Comparison and evaluation of the PLL techniques for the design of the grid-connected inverter systems.\" pp. 3865-3870. [96] E. Robles, S. Ceballos, J. Pou, J. L. Martín, J. Zaragoza, and P. Ibañez, “Variable-Frequency Grid-Sequence Detector Based on a Quasi-Ideal Low-Pass Filter Stage and a Phase-Locked Loop,” IEEE Transactions on Power Electronics, vol. 25, no. 10, pp. 2552-2563, 2010. [97] E. Courbon, S. Poullain, and J. Thomas, \"Analysis and synthesis of a digital high dynamics robust PLL for VSC-HVDC robust control.\" [98] L. Shi, and M. L. Crow, \"A novel PLL system based on adaptive resonant filter.\" pp. 1-8. [99] S. Yongsug, and T. A. Lipo, “Control scheme in hybrid synchronous stationary frame for PWM AC/DC converter under generalized unbalanced operating conditions,” IEEE Transactions on Industry Applications, vol. 42, no. 3, pp. 825-835, 2006. [100] S. Yongsug, V. Tijeras, and T. A. Lipo, \"A control method in dq synchronous frame for PWM boost rectifier under generalized unbalanced operating conditions.\" pp. 1425-1430 vol.3. [101] S. Hong-Seok, and N. Kwanghee, “Dual current control scheme for PWM converter under unbalanced input voltage conditions,” IEEE Transactions on Industrial Electronics, vol. 46, no. 5, pp. 953-959, 1999. [102] A. V. Stankovic, and T. A. Lipo, “A novel control method for input output harmonic elimination of the PWM boost type rectifier under unbalanced operating conditions,” IEEE Transactions on Power Electronics, vol. 16, no. 5, pp. 603-611, 2001. [103] L. A. Serpa, S. Ponnaluri, P. M. Barbosa, and J. W. Kolar, “A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverters to the Grid Through LCL Filters,” IEEE Transactions on Industry Applications, vol. 43, no. 5, pp. 1388-1400, 2007. [104] P. CortÉs, J. RodrÍguez, P. Antoniewicz, and M. Kazmierkowski, “Direct Power Control of an AFE Using Predictive Control,” IEEE Transactions on Power Electronics, vol. 23, no. 5, pp. 2516-2523, 2008. [105] T. Remus, L. Marco, and R. g. Pedro, \"Control of Grid Converters under Grid Faults,\" Grid Converters for Photovoltaic and Wind Power Systems, pp. 237-287: Wiley-IEEE Press, 2011. [106] D. J. Hanson, C. Horwill, B. D. Gemmell, and D. R. Monkhouse, \"A STATCOM-based relocatable SVC project in the UK for National Grid.\" pp. 532-537 vol.1. [107] G. Reed, J. Paserba, T. Croasdaile, R. Westover, S. Jochi, N. Morishima, M. Takeda, T. Sugiyama, Y. Hamasaki, T. Snow, and A. Abed, \"SDG&E Talega STATCOM project-system analysis, design, and configuration.\" pp. 1393-1398 vol.2. [108] Y. Qingguang, L. Pei, L. Wenhua, and X. Xiaorong, \"Overview of STATCOM technologies.\" pp. 647-652 Vol.2. [109] ABB, “SVC Light Reference List - Examples of Projects.” [110] C. Junling, Y. Zhizhu, W. Ping, and L. Yaohua, \"Capacitor voltage balancing control of cascaded multilevel inverter for high-power active power filters.\" pp. 1683-1687. [111] P. Münch, D. Görges, M. Izák, and S. Liu, \"Integrated current control, energy control and energy balancing of modular multilevel converters.\" pp. 150-155. [112] D. Siemaszko, A. Antonopoulos, K. Ilves, M. Vasiladiotis, L. Angquist, and H.-P. Nee, \"Evaluation of control and modulation methods for modular multilevel converters.\" pp. 746-753. [113] A. Dekka, B. Wu, N. R. Zargari, and R. L. Fuentes, “Dynamic Voltage Balancing Algorithm for Modular Multilevel Converter: A Unique Solution,” IEEE Transactions on Power Electronics, vol. 31, no. 2, pp. 952-963, 2016. [114] X. She, A. Q. Huang, and G. Wang, “3-D Space Modulation With Voltage Balancing Capability for a Cascaded Seven-Level Converter in a Solid-State Transformer,” IEEE Transactions on Power Electronics, vol. 26, no. 12, pp. 3778-3789, 2011. [115] O. J. K. Oghorada, C. J. Nwobu, and L. Zhang, \"Control of a single-star flying capacitor converter modular multi-level cascaded converter (SSFCC-MMCC) STATCOM for unbalanced load compensation.\" pp. 1-6. [116] O. J. K. Oghorada, and L. Zhang, \"Control of a Modular Multi-level Converter STATCOM for low voltage ride-through condition.\" pp. 3691-3696. [117] R. E. Betz, T. Summers, and T. Furney, \"Symmetry Compensation using a H-Bridge Multilevel STATCOM with Zero Sequence Injection.\" pp. 1724-1731. [118] T. J. Summers, R. E. Betz, and G. Mirzaeva, \"Phase leg voltage balancing of a cascaded H-Bridge converter based STATCOM using zero sequence injection.\" pp. 1-10. [119] N. Hatano, and T. Ise, “Control Scheme of Cascaded H-Bridge STATCOM Using Zero-Sequence Voltage and Negative-Sequence Current,” Power Delivery, IEEE Transactions on, vol. 25, no. 2, pp. 543-550, 2010. [120] P. Sochor, and H. Akagi, “Theoretical Comparison in Energy-Balancing Capability Between Star- and Delta-Configured Modular Multilevel Cascade Inverters for Utility-Scale Photovoltaic Systems,” Power Electronics, IEEE Transactions on, vol. 31, no. 3, pp. 1980-1992, 2016. [121] Y. Yifan, G. Konstantinou, B. Hredzak, and V. G. Agelidis, “Power Balance Optimization of Cascaded H-Bridge Multilevel Converters for Large-Scale Photovoltaic Integration,” Power Electronics, IEEE Transactions on, vol. 31, no. 2, pp. 1108-1120, 2016. [122] Y. Yu, G. Konstantinou, B. Hredzak, and V. G. Agelidis, “Power balance of cascaded H-bridge multilevel converters for large-scale photovoltaic integration,” IEEE Transactions on Power Electronics, vol. 31, no. 1, pp. 292-303, 2016. [123] b. e, and M. Bongiorno, “Investigation of Negative-Sequence Injection Capability of Cascaded H-Bridge Converters in Star and Delta Configuration,” IEEE Transactions on Power Electronics, vol. PP, no. 99, pp. 1-1, 2016. [124] E. Solas, G. Abad, J. A. Barrena, S. Aurtenetxea, A. Cárcar, and L. Zając, “Modular Multilevel Converter With Different Submodule Concepts&#x2014;Part I: Capacitor Voltage Balancing Method,” IEEE Transactions on Industrial Electronics, vol. 60, no. 10, pp. 4525-4535, 2013. [125] E. Solas, G. Abad, J. A. Barrena, S. Aurtenetxea, A. Cárcar, and L. Zając, “Modular Multilevel Converter With Different Submodule Concepts&#x2014;Part II: Experimental Validation and Comparison for HVDC Application,” IEEE Transactions on Industrial Electronics, vol. 60, no. 10, pp. 4536-4545, 2013. [126] I. B. Efika, “A Multi-level Multi-Modular Flying Capacitor Voltage Source Converter for High Power Applications,” University of Leeds, 2015. [127] I. B. Efika, “A Multi-level Multi-Modular Flying Capacitor Voltage Source Converter for High Power Applications,” University of Leeds, 2015. [128] S. Bifaretti, P. Zanchetta, F. Yue, F. Iov, and J. Clare, \"Power flow control through a multi-level H-bridge based power converter for Universal and Flexible Power Management in future electrical grids.\" pp. 1771-1778. [129] L. Maharjan, S. Inoue, H. Akagi, and J. Asakura, “State-of-charge (SOC)-balancing control of a battery energy storage system based on a cascade PWM converter,” Power Electronics, IEEE Transactions on, vol. 24, no. 6, pp. 1628-1636, 2009. [130] L. Maharjan, S. Inoue, and H. Akagi, “A transformerless energy storage system based on a cascade multilevel PWM converter with star configuration,” Industry Applications, IEEE Transactions on, vol. 44, no. 5, pp. 1621-1630, 2008. [131] S. Rajasekar, and R. Gupta, \"Solar photovoltaic power conversion using modular multilevel converter.\" pp. 1-6. [132] R. Feldman, A. Watson, J. Clare, P. Wheeler, D. Trainer, and R. Crookes, “DC fault ride-through capability and STATCOM operation of a hybrid voltage source converter arrangement for HVDC power transmission and reactive power compensation,” 2012. [133] X. She, and A. Huang, \"Circulating current control of double-star chopper-cell modular multilevel converter for HVDC system.\" pp. 1234-1239. [134] X. She, A. Huang, X. Ni, and R. Burgos, \"AC circulating currents suppression in modular multilevel converter.\" pp. 191-196. [135] J. Soderstrom, It's time to connect-Technical description of HVDC Light technology, Ludvika, Sweden: ABB AB Grid Systems-HVDC, 2005. [136] T. Lüth, M. M. C. Merlin, T. C. Green, F. Hassan, and C. D. Barker, “High-Frequency Operation of a DC/AC/DC System for HVDC Applications,” IEEE Transactions on Power Electronics, vol. 29, no. 8, pp. 4107-4115, 2014. [137] T. Lüth, M. M. C. Merlin, T. C. Green, C. D. Barker, F. Hassan, R. W. Critchley, R. W. Crookes, D. Trainer, and K. Dyke, \"Choice of AC operating voltage in HV DC/AC/DC system.\" pp. 1-5. [138] T. Lüth, M. M. C. Merlin, T. C. Green, C. D. Barker, F. Hassan, R. W. Critchley, R. W. Crookes, and K. Dyke, \"Performance of a DC/AC/DC VSC system to interconnect HVDC systems.\" pp. 1-6. [139] E. M. Farr, R. Feldman, A. J. Watson, R. P. Burgos, J. C. Clare, P. W. Wheeler, and D. Boroyevich, \"Alternate Arm Converter (AAC) operation under faulted AC-grid conditions.\" pp. 1-6. [140] M. M. Merlin, T. C. Green, P. D. Mitcheson, D. R. Trainer, R. Critchley, W. Crookes, and F. Hassan, “The Alternate Arm Converter: A New Hybrid Multilevel Converter With DC-Fault Blocking Capability,” 2014. [141] F. J. Moreno, M. M. C. Merlin, D. R. Trainer, T. C. Green, and K. J. Dyke, \"Zero phase sequence voltage injection for the alternate arm converter.\" pp. 1-6. [142] E. Amankwah, A. Watson, R. Feldman, J. Clare, and P. Wheeler, \"Experimental validation of a parallel hybrid modular multilevel voltage source converter for HVDC transmission.\" pp. 1607-1614. [143] R. Feldman, M. Tomasini, J. C. Clare, P. Wheeler, D. R. Trainer, and R. S. Whitehouse, \"A hybrid voltage source converter arrangement for HVDC power transmission and reactive power compensation.\" pp. 1-6. [144] A. Grid, “HVDC-VSC transmission technology of the future,” Alstom Grid, vol. 1, pp. 13-17, 2011. [145] C. Barker, \"HVDC for Beginners and Beyond,\" AREVA T&D publication, 2009. [146] M. Davies, M. Dommaschk, J. Dorn, J. Lang, D. Retzmann, and D. Soerangr, \"HVDC PLUS–Basics and principle of operation.\" [147] C. B. C. Oates, and D. Trainer, “VSC HVDC Converter Operation,” vol. ed. PEMD 2014, April 2014. [148] N. MacLeod, C. Davidson, and N. Kirby, \"A multi-level topology for Voltage Source Converter (VSC) HVDC transmission projects.\" [149] C. Oates, and C. Davidson, \"A comparison of two methods of estimating losses in the Modular Multi-Level Converter.\" pp. 1-10. [150] S. S. Fazel, S. Bernet, D. Krug, and K. Jalili, “Design and comparison of 4-kV neutral-point-clamped, flying-capacitor, and series-connected H-bridge multilevel converters,” IEEE Transactions on Industry Applications, vol. 43, no. 4, pp. 1032-1040, 2007. [151] A. K. Sadigh, V. Dargahi, and K. A. Corzine, “Analytical determination of conduction and switching power losses in flying-capacitor-based active neutral-point-clamped multilevel converter,” IEEE Transactions on Power Electronics, vol. 31, no. 8, pp. 5473-5494, 2016. [152] J. Li, X. Zhao, Q. Song, H. Rao, S. Xu, and M. Chen, \"Loss calculation method and loss characteristic analysis of MMC based VSC-HVDC system.\" pp. 1-6. [153] P. S. Jones, and C. C. Davidson, \"Calculation of power losses for MMC-based VSC HVDC stations.\" pp. 1-10. [154] P. S. Jones, and C. Davidson, \"Calculation of power losses for MMC-based VSC HVDC stations.\" pp. 1-10. [155] O. J. K. Oghorada, and L. Zhang, \"Performance evaluation of pulse width modulation techniques for losses reduction in modular multilevel flying capacitor converter.\" pp. 1-6. [156] F. Krismer, and J. W. Kolar, “Closed form solution for minimum conduction loss modulation of DAB converters,” IEEE Transactions on Power Electronics, vol. 27, no. 1, pp. 174-188, 2012. [157] L. Schwager, A. Tuysuz, C. Zwyssig, and J. W. Kolar, “Modeling and comparison of machine and converter losses for PWM and PAM in high-speed drives,” IEEE Transactions on Industry Applications, vol. 50, no. 2, pp. 995-1006, 2014. [158] S. Rohner, S. Bernet, M. Hiller, and R. Sommer, “Modulation, losses, and semiconductor requirements of modular multilevel converters,” Industrial Electronics, IEEE Transactions on, vol. 57, no. 8, pp. 2633-2642, 2010. [159] Q. Tu, and Z. Xu, \"Power losses evaluation for modular multilevel converter with junction temperature feedback.\" pp. 1-7. [160] D. Andler, R. Alvarez, S. Bernet, and J. Rodriguez, “Switching loss analysis of 4.5-kV–5.5-kA IGCTs within a 3L-ANPC phase leg prototype,” IEEE Transactions on Industry Applications, vol. 50, no. 1, pp. 584-592, 2014. [161] M. Schweizer, and J. W. Kolar, “Design and implementation of a highly efficient three-level T-type converter for low-voltage applications,” IEEE Transactions on Power Electronics, vol. 28, no. 2, pp. 899-907, 2013. [162] M. Hartmann, H. Ertl, and J. W. Kolar, “Current control of three-phase rectifier systems using three independent current controllers,” IEEE Transactions on Power electronics, vol. 28, no. 8, pp. 3988-4000, 2013. [163] M. A. Boost, and P. D. Ziogas, “State-of-the-art carrier PWM techniques: A critical evaluation,” Industry Applications, IEEE Transactions on, vol. 24, no. 2, pp. 271-280, 1988. [164] B. Velaerts, P. Mathys, E. Tatakis, and G. Bingen, \"A novel approach to the generation and optimization of three-level PWM wave forms for induction motor inverters.\" pp. 1255-1262. [165] D. G. Holmes, and T. A. Lipo, Pulse width modulation for power converters: principles and practice: John Wiley & Sons, 2003. [166] A. Massoud, S. Finney, and B. Williams, \"Control techniques for multilevel voltage source inverters.\" pp. 171-176. [167] J. Zubek, A. Abbondanti, and C. J. Norby, “Pulsewidth modulated inverter motor drives with improved modulation,” Industry Applications, IEEE Transactions on, no. 6, pp. 695-703, 1975. [168] A. M. Massoud, S. J. Finney, and B. W. Williams, \"Conduction loss calculation for multilevel inverter: a generalized approach for carrier-based PWM technique.\" pp. 226-230 Vol.1. [169] A. Massoud, S. Finney, and B. Williams, “High-power, high-voltage IGBT applications: series connection of IGBTs or multilevel converters?,” International journal of electronics, vol. 90, no. 11-12, pp. 763-778, 2003. [170] V. R. Stefanovic, and S. N. Vukosavic, \"Space-vector PWM voltage control with optimized switching strategy.\" pp. 1025-1033. [171] D. Peng, F. C. Lee, and D. Boroyevich, \"A novel SVM algorithm for multilevel three-phase converters.\" pp. 509-513. [172] J. H. Seo, C. H. Choi, and D.-S. Hyun, “A new simplified space-vector PWM method for three-level inverters,” Power Electronics, IEEE Transactions on, vol. 16, no. 4, pp. 545-550, 2001. [173] G. Brando, A. Dannier, A. Del Pizzo, and D. Iannuzzi, \"A SVM technique with homopolar voltage control in m-level multi modular converters.\" pp. 1531-1537. [174] I. Ahmed, V. B. Borghate, A. Matsa, P. M. Meshram, H. M. Suryawanshi, and M. A. Chaudhari, “Simplified space vector modulation techniques for multilevel inverters,” IEEE Transactions on Power Electronics, vol. 31, no. 12, pp. 8483-8499, 2016. [175] S. J. Watkins, and L. Zhang, \"Multilevel space vector PWM control schemes for a flying-capacitor inverter.\" pp. 12-17 Vol.1. [176] Z. B. Ibrahim, M. L. Hossain, M. N. Talib, R. Mustafa, and N. M. N. Mahadi, \"A five level cascaded H-bridge inverter based on space vector pulse width modulation technique.\" pp. 293-297. [177] S. Watkins, and L. Zhang, \"Multilevel space vector pwm control schemes for a flying-capacitor inverter.\" pp. 12-17. [178] A. Trentin, P. Zanchetta, and P. Wheeler, \"A New Investigation on Space Vector Modulation Technique for Voltage Source Inverter in AC Drive.\" pp. 1627-1632. [179] A. Trentin, P. Zanchetta, P. Wheeler, J. Clare, R. Wood, and W. Typton, \"Performance Assessment of SVM Modulation Techniques for Losses Reduction in Induction Motor Drives.\" pp. 1031-1037. [180] S. T. Joshi, A. Haneesh, G. Narayanan, and V. Ranganathan, “A computationally efficient PWM algorithm for multilevel inverters,” 2003. [181] Y.-H. Lee, B.-S. Suh, and D.-S. Hyun, “A novel PWM scheme for a three-level voltage source inverter with GTO thyristors,” Industry Applications, IEEE Transactions on, vol. 32, no. 2, pp. 260-268, 1996. [182] Y. Deng, K. H. Teo, C. Duan, T. G. Habetler, and R. G. Harley, “A fast and generalized space vector modulation scheme for multilevel inverters,” IEEE Transactions on Power Electronics, vol. 29, no. 10, pp. 5204-5217, 2014. [183] I. B. Efika, L. Zhang, A. Watson, and J. Clare, \"An overlapping multi-hexagon space vector modulation scheme for modular multilevel cascade converters.\" pp. 1-11. [184] S. Digital, “eZdsp F28335 Technical Reference,” Spectrum Digital Incorporated, 2007. [185] R. Duma, P. Dobra, M. Abrudean, and M. Dobra, \"Rapid prototyping of control systems using embedded target for TI C2000 DSP.\" pp. 1-5. [186] “IEEE Application Guide for IEEE Std 1547(TM), IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems,” IEEE Std 1547.2-2008, pp. 1-217, 2009. [187] “IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems - Amendment 1,” IEEE Std 1547a-2014 (Amendment to IEEE Std 1547-2003), pp. 1-16, 2014. [188] J. Bjorn, K. Patrik, A. Gunnar, H. Lennart, J. Tomas, and A. Sweden, “VSC-HVDC transmission with cascaded two-level converters,” 2011. [189] J. Peralta, H. Saad, S. Dennetiere, J. Mahseredjian, and S. Nguefeu, “Detailed and Averaged Models for a 401-Level MMC&#x2013;HVDC System,” IEEE Transactions on Power Delivery, vol. 27, no. 3, pp. 1501-1508, 2012. [190] M. S. Suleiman, A. A.-S. Mohammad, I. O. Georgios, and H. Babar, \"DC-Link Capacitor Current and Sizing in NPC and CHB Inverters,\" Power Electronic Converters for Microgrids, p. 352: Wiley-IEEE Press, 2014. [191] C. D. Townsend, T. J. Summers, J. Vodden, A. J. Watson, R. E. Betz, and J. C. Clare, “Optimization of Switching Losses and Capacitor Voltage Ripple Using Model Predictive Control of a Cascaded H-Bridge Multilevel StatCom,” IEEE Transactions on Power Electronics, vol. 28, no. 7, pp. 3077-3087, 2013. [192] G. Farivar, B. Hredzak, and V. G. Agelidis, “Reduced-Capacitance Thin-Film H-Bridge Multilevel STATCOM Control Utilizing an Analytic Filtering Scheme,” IEEE Transactions on Industrial Electronics, vol. 62, no. 10, pp. 6457-6468, 2015. [193] C. D. Townsend, Y. Yu, G. Konstantinou, and V. G. Agelidis, “Cascaded H-Bridge Multilevel PV Topology for Alleviation of Per-Phase Power Imbalances and Reduction of Second Harmonic Voltage Ripple,” IEEE Transactions on Power Electronics, vol. 31, no. 8, pp. 5574-5586, 2016. [194] G. Farivar, C. Townsend, B. Hredzak, J. Pou, and V. Agelidis, “A Low Capacitance Cascaded H-Bridge Multi-Level StatCom.” [195] M. J. Waite, “Active power filter for unbalanced distribution networks using a flying-capacitor multi-level inverter,” University of Leeds, 2011. [196] “HFBR-0501 Series Datasheet,” ed: Avago Technologies. [197] “Voltage Transducer LV 25-P,” ed: LEM. [198] “Current Transducer LA 55-P,” ed: LEM. [199] H. Akagi, E. H. Watanabe, and M. Aredes, Instantaneous power theory and applications to power conditioning: John Wiley & Sons, 2007."],"dcterms:accessrights":["public"],"dc:title":["Modular Multilevel Cascaded Flying Capacitor STATCOM for Balanced and Unbalanced Load Compensation"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:23:50Z"}