{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:19145"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:19145","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Ultrafast pulsed laser plasma fabrication of erbium doped thin film sensors","abstract":"Erbium (Er3+) ions have been extensively used in the field of integrated photonics due to it's characteristic fluorescence properties which can be used to amplify the optical signal in fibre based optical communication systems. In this study, novel materials were developed by doping Er3+ ions in glass polymer (GP) superlattice coated on a silicon substrate to investigate its application as an infrared (IR) sensor. The conventional IR detectors are classified as thermal detector and photonic detectors. The conventional photonic detector has better sensing capabilities however, they are required to be cooled down to 77 K for sensing IR radiations. Thus the current requirement is to develop uncooled IR detector which can sense minute changes in the temperature. The initial studies show that GP superlattice coated tipless cantilevers are able to sense changes in temperature with a resolution of 2 mK per nm deflection of the cantilever. The second part of the study was to dope Er3+ ions with or without Ytterbium (Yb3+) ions as a co-dopant in fused silica for glucose sensing. The fabrication was done using the pulsed laser deposition method which is a well-established technique for manufacturing nanoengineered thin films. The parameters for fabrication of optical glucose sensor were altered to assess the impact of different parameters such as chamber oxygen pressure, deposition time, Er3+ and Yb3+ ions concentrations on structural and fluorescence characteristics of thin films. The spectroscopic characterisation revealed that the low doping (0.25 mol %) concentration of Er3+ ions in the thin films results in longer fluorescence lifetime of up to 12.4 ms while the doping of Er3+ ion in fused silica has been achieved to 2.4 micron depth. The fabricated thin films were also characterized using techniques such as absorption spectroscopy, fluorescence spectroscopy, prism coupling, energy dispersive x-ray mapping using transmission electron microscopy. The thin films with longer fluorescence lifetime were selected for glucose monitoring device development. Poor management of diabetes mellitus can result in various complications such as cardiovascular disease, retinopathy, neuropathy and limb amputations. Diabetes control and complication trial highlighted that, with better glycaemic control resulted in reduced complications due to diabetes. The current techniques available to measure glucose levels are invasive in nature. Presently there is a desperate need for non-invasive sensing technology which is considered as holy grail for glycaemic control. The glucose sensing capabilities of the Er3+ ions doped fused silica was tested using in-vitro glucose measurement in aqueous solutions, blood samples, and intralipids solution. A laboratory bench prototype was developed for a pilot clinical study on people with type 1 diabetes. The change in fluorescence lifetime due to change in glucose concentrations was analysed. The calibrated values were then correlated with the actual glucose reading from finger prick handheld glucose meter and invasive continuous glucose monitor (ICGM). The results were analysed using clarke error grid (CEG) analysis which is a standard statistical analysis tool to assess the accuracy of the device. The next stage of the development includes fabricating a new batch of the photonics chips which has shown the glucose sensing capabilities and thereafter carrying out in-vitro testing as well as carry out the second stage of clinical trials.","abstract_html":"Erbium (Er3+) ions have been extensively used in the field of integrated photonics due to it&#x27;s characteristic fluorescence properties which can be used to amplify the optical signal in fibre based optical communication systems. In this study, novel materials were developed by doping Er3+ ions in glass polymer (GP) superlattice coated on a silicon substrate to investigate its application as an infrared (IR) sensor. The conventional IR detectors are classified as thermal detector and photonic detectors. The conventional photonic detector has better sensing capabilities however, they are required to be cooled down to 77 K for sensing IR radiations. Thus the current requirement is to develop uncooled IR detector which can sense minute changes in the temperature. The initial studies show that GP superlattice coated tipless cantilevers are able to sense changes in temperature with a resolution of 2 mK per nm deflection of the cantilever. The second part of the study was to dope Er3+ ions with or without Ytterbium (Yb3+) ions as a co-dopant in fused silica for glucose sensing. The fabrication was done using the pulsed laser deposition method which is a well-established technique for manufacturing nanoengineered thin films. The parameters for fabrication of optical glucose sensor were altered to assess the impact of different parameters such as chamber oxygen pressure, deposition time, Er3+ and Yb3+ ions concentrations on structural and fluorescence characteristics of thin films. The spectroscopic characterisation revealed that the low doping (0.25 mol %) concentration of Er3+ ions in the thin films results in longer fluorescence lifetime of up to 12.4 ms while the doping of Er3+ ion in fused silica has been achieved to 2.4 micron depth. The fabricated thin films were also characterized using techniques such as absorption spectroscopy, fluorescence spectroscopy, prism coupling, energy dispersive x-ray mapping using transmission electron microscopy. The thin films with longer fluorescence lifetime were selected for glucose monitoring device development. Poor management of diabetes mellitus can result in various complications such as cardiovascular disease, retinopathy, neuropathy and limb amputations. Diabetes control and complication trial highlighted that, with better glycaemic control resulted in reduced complications due to diabetes. The current techniques available to measure glucose levels are invasive in nature. Presently there is a desperate need for non-invasive sensing technology which is considered as holy grail for glycaemic control. The glucose sensing capabilities of the Er3+ ions doped fused silica was tested using in-vitro glucose measurement in aqueous solutions, blood samples, and intralipids solution. A laboratory bench prototype was developed for a pilot clinical study on people with type 1 diabetes. The change in fluorescence lifetime due to change in glucose concentrations was analysed. The calibrated values were then correlated with the actual glucose reading from finger prick handheld glucose meter and invasive continuous glucose monitor (ICGM). The results were analysed using clarke error grid (CEG) analysis which is a standard statistical analysis tool to assess the accuracy of the device. The next stage of the development includes fabricating a new batch of the photonics chips which has shown the glucose sensing capabilities and thereafter carrying out in-vitro testing as well as carry out the second stage of clinical trials.","abstract_has_math":false,"creators":["Kakkar, Tarun"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Jose, Gin","Saha, Sikha","Grant, Peter","Ajjan, Ramzi"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-09","date_published":"2017-09","updated_at":"2026-11-18T22:24:54Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.733565"],"render_values":[{"text":"uk.bl.ethos.733565","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["Seamatics","Non invasive sensor","MAST STC"],"render_values":[{"text":"Seamatics","href":null,"code":true},{"text":"Non invasive sensor","href":null,"code":true},{"text":"MAST STC","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/19145/1/thesis.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A19145","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jose, Gin","Saha, Sikha","Grant, Peter","Ajjan, Ramzi"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC","Glucosense diagnostics","NIHR i4i","DSTL"]},{"key":"dc:creator","label":"Author","values":["Kakkar, Tarun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-09"]},{"key":"dc:date.issued","label":"Date","values":["2017-09"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Faculty of Medicine and Health (Leeds)","Leeds Institute of Genetics, Health and Therapeutics (LIGHT)","School of Chemical and Process Engineering (Leeds)","Institute for Materials Research (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/19145/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["References Abcam (2017). Counting cells using a hemocytometer | abcam. http: //www.abcam.com/protocols/counting-cells-using-a-haemocytometer, (Accessed on 12/08/2017). 145 Adams, A., Schinke, D. & Capio, C. (1979). An evaluation of the prism coupler for measuring the thickness and refractive index of dielectric �lms on silicon substrates. Journal of The Electrochemical Society, 126, 1539{1543. 67 Adler, A.I., Stratton, I.M., Neil, H.A.W., Yudkin, J.S., Matthews, D.R., Cull, C.A., Wright, A.D., Turner, R.C. & Holman, R.R. (2000). Association of systolic blood pressure with macrovascular and microvascular complications of type 2 diabetes (ukpds 36): prospective observational study. Bmj, 321, 412{419. 24 Ainslie, B.J. (1991). A review of the fabrication and properties of erbium-doped �bers for optical ampli�ers. Journal of Lightwave Technology, 9, 220{227. 93 Albani, J.R. (2008). Principles and applications of uorescence spectroscopy. John Wiley & Sons. xv, xxvii, 15, 16, 17, 18, 19 Alexeeva, N.V. (2011). Characterization of skin tissue heterogeneity with near- infrared microspectroscopy and its e�ects on noninvasive measurements of glu- cose. The University of Iowa. 26 201 REFERENCES Allen, R. & David, G. (1969). The zeiss-nomarski di�erential interference equipment for transmitted-light microscopy. Zeitschrift fur wissenschaftliche Mikroskopie und mikroskopische Technik, 69, 193{221. 61 Amerov, A.K., Chen, J. & Arnold, M.A. (2004). Molar absorptivities of glucose and other biological molecules in aqueous solutions over the �rst overtone and combination regions of the near-infrared spectrum. Applied spec- troscopy, 58, 1195{1204. xvi, 28, 30, 31, 159, 161, 162 Anderson, J.M. & Shive, M.S. (2012). Biodegradation and biocompatibility of pla and plga microspheres. Advanced drug delivery reviews, 64, 72{82. 136 Anderson, R.R. & Parrish, J.A. (1981). The optics of human skin. Journal of investigative dermatology, 77, 13{19. xvi, 30, 32 Astles, J.R., Sedor, F.A. & Toffaletti, J.G. (1996). Evaluation of the ysi 2300 glucose analyzer: algorithm-corrected results are accurate and speci�c. Clinical biochemistry, 29, 27{31. 24 Ba, L.A., D�oring, M., Jamier, V. & Jacob, C. (2010). Tellurium: an element with great biological potency and potential. Organic & biomolecular chemistry, 8, 4203{4216. 154 Babich, H. & Borenfreund, E. (1990). Applications of the neutral red cytotoxicity assay to in vitro toxicology. Alternatives to laboratory animals: ATLA. 150 Balling, P. & Schou, J. (2013). Femtosecond-laser ablation dynamics of dielectrics: basics and applications for thin �lms. Reports on Progress in Physics, 76, 036502. 84 Banks, P., Dinh, L., Stuart, B., Feit, M., Komashko, A., Rubenchik, A., Perry, M. & McLean, W. (1999). Short-pulse laser deposition of diamond-like carbon thin �lms. Applied Physics A, 69, S347{S353. 38 202 REFERENCES Beletic, J.W., Blank, R., Gulbransen, D., Lee, D., Loose, M., Piquette, E.C., Sprafke, T., Tennant, W.E., Zandian, M. & Zino, J. (2008). Teledyne imaging sensors: Infrared imaging technologies for astronomy & civil space. In Proc. SPIE, vol. 7021. 9 Berezin, M.Y. & Achilefu, S. (2010). Fluorescence lifetime measurements and biological imaging. Chemical reviews, 110, 2641{2684. 160 Berneschi, S., Nunzi Conti, G., B�any�asz, I., Watterich, A., Khanh, N., Fried, M., P�aszti, F., Brenci, M., Pelli, S. & Righini, G. (2007). Ion beam irradiated channel waveguides in er 3+-doped tellurite glass. Applied physics letters, 90, 121136. 47 Bharate, J.B., Batarseh, Y.S., Wani, A., Sharma, S., Vishwakarma, R.A., Kaddoumi, A., Kumar, A. & Bharate, S.B. (2015). Synthesis and p-glycoprotein induction activity of colupulone analogs. Organic & biomolecu- lar chemistry, 13, 5488{5496. 153 Bistrian, B.R. (2001). Hyperglycemia and infection: which is the chicken and which is the egg? Journal of Parenteral and Enteral Nutrition, 25, 180{181. 20 Bland, J.M. & Altman, D.G. (2007). Agreement between methods of measurement with multiple observations per individual. Journal of biopharmaceu- tical statistics, 17, 571{582. 187 Bloomfield, P. (2004). Fourier analysis of time series: an introduction. John Wiley & Sons. 88 Borenfreund, E. & Puerner, J.A. (1985). A simple quantitative procedure using monolayer cultures for cytotoxicity assays (htd/nr-90). Methods in Cell Science, 9, 7{9. 150 Bradley, J.D. (2017). Rare earth doped light emitting thin �lm materials for silicon photonics. In Meeting Abstracts, 17, 1013{1013, The Electrochemical Society. 5 203 REFERENCES Briscoe, V.J. & Davis, S.N. (2006). Hypoglycemia in type 1 and type 2 diabetes: physiology, pathophysiology, and management. Clinical Diabetes, 24, 115{121. 20 Br�uckner, R. (1970). Properties and structure of vitreous silica. i. Journal of non-crystalline solids, 5, 123{175. 13 Bulgakova, N., Stoian, R., Rosenfeld, A., Hertel, I. & Campbell, E. (2004). Electronic transport and consequences for material removal in ultrafast pulsed laser ablation of materials. Physical Review B, 69, 054102. 44 Cao, H. & Sheehan, S.W. (2013). Applied physics: A cascade laser's random walk. Nature, 503, 200{201. 159 Carey, J. (2002). Structure of multi-oxygen-related defects in erbium-implanted silicon. Journal of Physics: Condensed Matter, 14, 8537. 83 Chandrappan, J., Murray, M., Kakkar, T., Petrik, P., Agocs, E., Zolnai, Z., Steenson, D., Jha, A. & Jose, G. (2015). Target dependent femtosecond laser plasma implantation dynamics in enabling silica for high density erbium doping. Scienti�c reports, 5, 14037. 82, 94, 112 Chen, C.Y. & Chi, S. (1993). Attenuation and uorescence characteristics of optical signals propagating in an erbium-doped �ber. IEEE photonics technol- ogy letters, 5, 1020{1022. 161 Cheney, B. (2007). Introduction to scanning electron microscopy. Materials Engineering department San Jose State University. 65 Chrisey, D.B. & Hubler, G.K. (1994). Pulsed laser deposition of thin �lms. 12, 36 Ciminelli, C., Campanella, C.M., Dell'Olio, F., Campanella, C.E. & Armenise, M.N. (2013). Label-free optical resonant sensors for biochemical applications. Progress in Quantum Electronics, 37, 51{107. 7 204 REFERENCES Clark, L.C. & Lyons, C. (1962). Electrode systems for continuous monitoring in cardiovascular surgery. Annals of the New York Academy of sciences, 102, 29{45. 6 Clarke, W.L. (2005). The original clarke error grid analysis (ega). Diabetes technology & therapeutics, 7, 776{779. 185 Clarke, W.L., Cox, D., Gonder-Frederick, L.A., Carter, W. & Pohl, S.L. (1987). Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes care, 10, 622{628. 185 Claxton, N.S., Fellers, T.J. & Davidson, M.W. (2006). Laser scanning confocal microscopy. Department of Optical Microscopy and Digital Imaging, Florida State University, Tallahassee, http://www. olympusconfocal. com/theory/LSCMIntro. pdf . 62 Clothier, R. (1990). The frame modi�ed neutral red uptake cytotoxicity test. Invittox protocol . 150 Cohen, M.L. (1977). Measurement of the thermal properties of human skin. a review. Journal of investigative dermatology, 69, 333{338. 159 Corporation, M. (2017a). Model 2010/m overview. 69 Corporation, N. (2017b). Shear amount in di�erential interference. xvi, 61 Corsi, C. (2010). History highlights and future trends of infrared sensors. Jour- nal of modern optics, 57, 1663{1686. 9 Couairon, A., Sudrie, L., Franco, M., Prade, B. & Mysyrowicz, A. (2005). Filamentation and damage in fused silica induced by tightly focused femtosecond laser pulses. Physical Review B, 71, 125435. 80 Craciun, V., Amirhaghi, S., Craciun, D., Elders, J., Gardeniers, J.G. & Boyd, I.W. (1995). E�ects of laser wavelength and uence on the growth of zno thin �lms by pulsed laser deposition. Applied surface science, 86, 99{106. 116 205 REFERENCES Cryer, P.E., Davis, S.N. & Shamoon, H. (2003). Hypoglycemia in diabetes. Diabetes care, 26, 1902{1912. 20 Cueff, S., Labb�e, C., Jambois, O., Garrido, B., Portier, X. & Rizk, R. (2011). Thickness-dependent optimization of er3+ light emission from siliconrich silicon oxide thin �lms. Nanoscale research letters, 6, 395. 76 Damiano, E.R., El-Khatib, F.H., Zheng, H., Nathan, D.M. & Russell, S.J. (2013). A comparative e�ectiveness analysis of three continuous glucose monitors. Diabetes Care, 36, 251{259. xxviii, 194 Davis, K., Agarwal, A., Tomozawa, M. & Hirao, K. (1996). Quantitative infrared spectroscopic measurement of hydroxyl concentrations in silica glass. Journal of non-crystalline solids, 203, 27{36. 13 DeFronzo, R.A. (1988). The triumvirate: �-cell, muscle, liver. a collusion responsible for niddm. Diabetes, 37, 667{687. 20 DeFronzo, R.A. (1997). Pathogenesis of type2 daiabetes: metabolic and molecular implications for identhfying diabetes genes. Diabetes reviews, 5, 177{269. 20, 23 Diego, S. (2017). Hemocytometer cell counting protocol. 141 Directive, C. (1993). 93/42/eec of 14 june 1993 concerning medical devices. 136 Directive, I.V.D. (1998). 98/79/ec. Vitro Diagnostic Medical Device Directive. 136 Douglas, A. & Teaney, D. (1988). Hand-held glucose monitor and recorder. In Engineering in Medicine and Biology Society, 1988. Proceedings of the An- nual International Conference of the IEEE, 747{748, IEEE. 24 Du, D., Liu, X., Korn, G., Squier, J. & Mourou, G. (1994). Laser-induced breakdown by impact ionization in sio2 with pulse widths from 7 ns to 150 fs. Applied physics letters, 64, 3071{3073. 44 206 REFERENCES Eason, R. (2007). Pulsed laser deposition of thin �lms: applications-led growth of functional materials. John Wiley & Sons. 12, 36, 37, 46, 116 Egerton, R.F. (2005). Physical principles of electron microscopy. Springer. 67 El Hamzaoui, H., Bigot, L., Bouwmans, G., Razdobreev, I., Bouazaoui, M. & Capoen, B. (2011). From molecular precursors in solution to microstructured optical �ber: a sol-gel polymeric route. Optical Materials Ex- press, 1, 234{242. 108 El-Mallawany, R. (1999). Tellurite glasses: Part 2. anelastic, phase separation, debye temperature and thermal properties. Materials chemistry and physics, 60, 103{131. xxvii, 116, 118 Estevez, M.C., Otte, M.A., Sepulveda, B. & Lechuga, L.M. (2014). Trends and challenges of refractometric nanoplasmonic biosensors: a review. Analytica chimica acta, 806, 55{73. 7 Fan, X., White, I.M., Shopova, S.I., Zhu, H., Suter, J.D. & Sun, Y. (2008). Sensitive optical biosensors for unlabeled targets: A review. analytica chimica acta, 620, 8{26. xv, 7, 8 Faust, C.B. (1992). Modern chemical techniques. Royal Soc. of Chemistry, Educ. Divn. xvii, 71, 72 Favennec, P., l'Haridon, H., Moutonnet, D., Salvi, M. & Gauneau, M. (1990). Optical activation of er3+ implanted in silicon by oxygen impurities. Japanese Journal of Applied Physics, 29, L524. 83 Feng, X., Tanabe, S. & Hanada, T. (2001). Hydroxyl groups in erbiumdoped germanotellurite glasses. Journal of non-crystalline solids, 281, 48{54. 91 Fischer-Hirchert, U.H. (2015). Photonic Packaging Sourcebook: Fiber-Chip Coupling for Optical Components, Basic Calculations, Modules. Springer. 86, 88, 93 Fox, S.I. (2009). Fundamentals of human physiology. McGraw-Hill. xv, 21 207 REFERENCES Gadelmawla, E., Koura, M., Maksoud, T., Elewa, I. & Soliman, H. (2002). Roughness parameters. Journal of materials processing technology, 123, 133{145. xvi, xvii, 63, 64, 65 Gal, A., Harman-Boehm, I., Naidis, E., Mayzel, Y. & Trieman, L. (2011). Validity of glucotrack R , a non-invasive glucose monitor, for variety of diabetics. Age, 1, 61. xxviii, 194 Gamaly, E.G., Rode, A.V. & Luther-Davies, B. (1999). Ultrafast ablation with high-pulse-rate lasers. part i: Theoretical considerations. Journal of Applied Physics, 85, 4213{4221. 37 Gamaly, E.G., Rode, A.V., Luther-Davies, B. & Tikhonchuk, V.T. (2002). Ablation of solids by femtosecond lasers: Ablation mechanism and ablation thresholds for metals and dielectrics. Physics of Plasmas (1994-present), 9, 949{957. 12, 36, 37 Gamaly, E.G., Rode, A.V., Uteza, O., Kolev, V., Luther-Davies, B., Bauer, T., Koch, J., Korte, F. & Chichkov, B. (2004). Control over a phase state of the laser plume ablated by femtosecond laser: Spatial pulse shaping. Journal of Applied Physics, 95, 2250{2257. 37 Gehrz, R., Becklin, E., De Pater, I., Lester, D., Roellig, T. & Woodward, C. (2009). A new window on the cosmos: The stratospheric observatory for infrared astronomy (so�a). Advances in Space Research, 44, 413{432. 9 Gepts, W. (1965). Pathologic anatomy of the pancreas in juvenile diabetes mellitus. Diabetes, 14, 619{633. 22 Giannuzzi, L.A. et al. (2006). Introduction to focused ion beams: instrumen- tation, theory, techniques and practice. Springer Science & Business Media. 66 208 REFERENCES Gierak, J., Mailly, D., Faini, G., Pelouard, J., Denk, P., Pardo, F., Marzin, J., Septier, A., Schmid, G., Ferr�e, J. et al. (2001). Nanofabrication with focused ion beams. Microelectronic Engineering, 57, 865{875. 66 Girard, S., Ouerdane, Y., Tortech, B., Marcandella, C., Robin, T., Cadier, B., Baggio, J., Paillet, P., Ferlet-Cavrois, V., Boukenter, A. et al. (2009). Radiation e�ects on ytterbium-and ytterbium/erbiumdoped double-clad optical �bers. IEEE Transactions on Nuclear Science, 56, 3293{3299. 93, 99, 112 Gonen, B., Rochman, H., Rubenstein, A., Tanega, S. & Horwitz, D. (1977). Haemoglobin a1: an indicator of the metabolic control of diabetic patients. The Lancet, 310, 734{737. 20 Grew, R.S., Ebendorff-Heidepriem, H., Veitch, P.J. & Monro, T.M. (2006). Concentration e�ects in erbium doped tellurite glass. In Optoelectronic and Microelectronic Materials and Devices, 2006 Conference on, 196{199, IEEE. 108 Griscom, D.L. (1991). Optical properties and structure of defects in silica glass. Journal of the Ceramic Society of Japan, 99, 923{942. 91 Group, D.R.S.R. et al. (1978). Photocoagulation treatment of proliferative diabetic retinopathy: the second report of diabetic retinopathy study �ndings. Ophthalmology, 85, 82{106. 23 Group, U.P.D.S. et al. (1988). Prospective diabetes study iv. characteristics of newly presenting type 2 diabetic patients: male preponderance and obesity at di�erent ages. multicenter study. Diabetic Medicine, 5, 154{159. 24 Guo, J., Keathley, P.D. & Hastings, J. (2008). Dual-mode surfaceplasmon- resonance sensors using angular interrogation. Optics letters, 33, 512{ 514. 8 Haglund, R.F., Miller, J.C., Lucatorto, T. & De Graef, M. (1997). Laser Ablation and Desorption, vol. 30. Academic Press. 12 209 REFERENCES Harman-Boehm, I., Gal, A., Raykhman, A.M., Zahn, J.D., Naidis, E. & Mayzel, Y. (2009). Noninvasive glucose monitoring: a novel approach. 26 Hart, G. (1927). The nomenclature of silica. American Mineralogist , 12, 383{ 395. 12 Harvey, J.E. (1976). Light-scattering characteristics of optical surfaces. 80 Hayashi, H., Sugimoto, N., Tanabe, S. & Ohara, S. (2006). E�ect of hydroxyl groups on erbium-doped bismuth-oxide-based glasses for �ber ampli�ers. Journal of applied physics, 99, 093105. 91 Hayashi, S. (1990). Di�erential interference microscope. US Patent 4,964,707. 61 Hetherington, G., Jack, K. & Ramsay, M. (1965). High-temperature electrolysis of vitreous silica. i. oxidation ultra-violet induced uorescence and irradiation colour. Physics and Chemistry of Glasses, 6, 6{+. 13 Hillier, T.A., Abbott, R.D. & Barrett, E.J. (1999). Hyponatremia: evaluating the correction factor for hyperglycemia. The American journal of medicine, 106, 399{403. 28 Hnizdo, E. & Vallyathan, V. (2003). Chronic obstructive pulmonary disease due to occupational exposure to silica dust: a review of epidemiological and pathological evidence. Occupational and Environmental Medicine, 60, 237{243. 136 Holman, R. & Turner, R. (1979). Maintenance of basal plasma glucose and insulin concentrations in maturity-onset diabetes. Diabetes, 28, 227{230. 20 Homola, J. (2008). Surface plasmon resonance sensors for detection of chemical and biological species. Chemical reviews, 108, 462{493. 7 Huang, M. (2003). Stress e�ects on the performance of optical waveguides. International Journal of Solids and Structures, 40, 1615{1632. 62, 74, 80 210 REFERENCES Ibrahim, M.H., Kassim, N.M., Mohammad, A.B. & Gang, S.Y. (2004a). Modelling of rib optical waveguide structure using e�ective index method. Ju- rnal Elektrika, 6, 43{49. 69 Ibrahim, M.H., Kassim, N.M., Mohammad, A.B. & Chin, M.K. (2006). Prism coupling measurement of benzocyclobutene (bcb 4024-40) polymer for optical devices application. Elektrika Journal of Electrical Engineering, 8, 13{ 16. xvii, 68, 69 Ibrahim, Y.M., Alsharaeh, E.H. & El-Shall, M.S. (2004b). Evidence for penning ionization in the generation of electronically excited states of transition metal cations by laser vaporization. The Journal of Physical Chemistry B, 108, 3959{3962. 88 ISO, E. (2008). 10993-12: 2008{biological evaluation of medical devices{part 12: Sample preparation and reference materials (iso 10993-12: 2007). German version: DIN EN ISO, 10993{10912. 136, 147, 151 ISO, I. (2009). 10993{5: 2009 biological evaluation of medical devices{part 5: Tests for in vitro cytotoxicity. International Organization for Standardization, Geneva. 136, 147, 149, 150, 152, 153 Jeng, J.H., Hsieh, C., Lan, W., Chang, M., Lin, S., Hahn, L. & Kuo, M. (1998). Cytotoxicity of sodium uoride on human oral mucosal �broblasts and its mechanisms. Cell biology and toxicology, 14, 383{389. 155 Jorgenson, R. & Yee, S. (1993). A �ber-optic chemical sensor based on surface plasmon resonance. Sensors and Actuators B: Chemical , 12, 213{220. 8 Karim, A. & Andersson, J.Y. (2013). Infrared detectors: Advances, challenges and new technologies. In IOP Conference Series: Materials Science and Engineering, vol. 51, 012001, IOP Publishing. 9, 10 Keiser, G. (2003). Optical �ber communications. Wiley Online Library. 13 Kersten, R.T. (1975). A new method for measuring refractive index and thickness of liquid and deposited solid thin �lms. Optics Communications, 13, 327{ 329. 67 211 REFERENCES Kholodkov, A. & Golant, K. (2005). Er 3+ ions luminescence in non-fused silicate glasses fabricated by spcvd. Optical materials, 27, 1178{1186. 108 Kik, P.G. (2001). Energy transfer in erbium doped optical waveguides based on silicon. Ph.D. thesis. 12, 15 Kim, I.Y., Joachim, E., Choi, H. & Kim, K. (2015). Toxicity of silica nanoparticles depends on size, dose, and cell type. Nanomedicine: Nanotech- nology, Biology and Medicine, 11, 1407{1416. 136 Kitamura, R., Pilon, L. & Jonasz, M. (2007). Optical constants of silica glass from extreme ultraviolet to far infrared at near room temperature. Applied optics, 46, 8118{8133. 12 Klarh�ofer, M., Csapo, B., Balassy, C., Szeles, J. & Moser, E. (2001). High-resolution blood ow velocity measurements in the human �nger. Mag- netic resonance in medicine, 45, 716{719. 170 Klocke, D., Schmitz, A., Soltner, H., Bousack, H. & Schmitz, H. (2011). Infrared receptors in pyrophilous (\\�re loving\") insects as model for new un-cooled infrared sensors. Beilstein journal of nanotechnology, 2, 186. 126 Koughia, C. & Kasap, S.O. (2008). Excitation di�usion in gegase and gegas glasses heavily doped with er 3+. Optics express, 16, 7709{7714. 106 Kovatchev, B., Anderson, S., Heinemann, L. & Clarke, W. (2008). Comparison of the numerical and clinical accuracy of four continuous glucose monitors. Diabetes care, 31, 1160{1164. xxviii, 194 Landau, L.D., Bell, J., Kearsley, M., Pitaevskii, L., Lifshitz, E. & Sykes, J. (2013). Electrodynamics of continuous media, vol. 8. elsevier. 41 Lang, W. (1982). Nomarski di�erential interference-contrast microscopy. Oberkochen, Carl Zeiss. 61 Latif, A. (2000). Nanofabrication using focused ion beam. Ph.D. thesis, University of Cambridge. 66 212 REFERENCES Lawson, W., Nielsen, S., Putley, E. & Young, A. (1959). Preparation and properties of hgte and mixed crystals of hgte-cdte. Journal of Physics and Chemistry of Solids, 9, 325{329. 9 LeMieux, M.C., McConney, M.E., Lin, Y.H., Singamaneni, S., Jiang, H., Bunning, T.J. & Tsukruk, V.V. (2006). Polymeric nanolayers as actuators for ultrasensitive thermal bimorphs. Nano letters, 6, 730{734. 132 Liedberg, B., Nylander, C. & Lunstr�om, I. (1983). Surface plasmon resonance for gas detection and biosensing. Sensors and actuators, 4, 299{304. 8 Liu, Y., L�u, C., Li, M., Zhang, L. & Yang, B. (2008). High refractive index organic{inorganic hybrid coatings with tio 2 nanocrystals. Colloids and Surfaces A: Physicochemical and Engineering Aspects, 328, 67{72. 67 Lorazo, P., Lewis, L.J. & Meunier, M. (2003). Short-pulse laser ablation of solids: from phase explosion to fragmentation. Physical review letters, 91, 225502. 40 Lourenc�o, M., Milo�sevi�c, M., Gorin, A., Gwilliam, R. & Homewood, K. (2016). Super-enhancement of 1.54 �m emission from erbium codoped with oxygen in silicon-on-insulator. Scienti�c reports, 5. 83 Luther-Davies, B. & Gamali�� (????). Matter in ultrastrong laser �elds. 41 Ma, H., Shieh, K.J., Qiao, T.X. & Cherng, S. (2006). Transmission electron microscopy (tem) and scanning electron microscopy (sem). Nature and Science, 14. 67 Maciel, E., Bolzan, R., Braga, A. & Rocha, J. (2000). Diphenyl diselenide and diphenyl ditelluride di�erentially a�ect �-aminolevulinate dehydratase from liver, kidney, and brain of mice. Journal of Biochemical and Molecular Toxicology, 14, 310{319. 154 213 REFERENCES Maier, J.S., Walker, S.A., Fantini, S., Franceschini, M.A. & Gratton, E. (1994). Possible correlation between blood glucose concentration and the reduced scattering coe�cient of tissues in the near infrared. Optics letters, 19, 2062{2064. 29, 33, 159 Mailis, S., Zergioti, I., Koundourakis, G., Ikiades, A., Patentalaki, A., Papakonstantinou, P., Vainos, N.A. & Fotakis, C. (1999). Etching and printing of di�ractive optical microstructures by a femtosecond excimer laser. Applied optics, 38, 2301{2308. 38 Maine, P., Strickland, D., Bado, P., Pessot, M. & Mourou, G. (1988). Generation of ultrahigh peak power pulses by chirped pulse ampli�cation. IEEE Journal of Quantum electronics, 24, 398{403. 49 Matsuoka, M. & Tohno, S.i. (1995). 1.54 �m photoluminescence of in situ erbium-oxygen co-doped silicon �lms grown by ion-beam epitaxy. Journal of applied physics, 78, 2751{2757. 83 Mattarelli, M., Montagna, M., Zampedri, L., Chiasera, A., Ferrari, M., Righini, G., Fortes, L., Gonc�alves, M., Santos, L. & Almeida, R. (2005). Self-absorption and radiation trapping in er3+-doped teo2-based glasses. EPL (Europhysics Letters), 71, 394. 106 McAulay, V., Deary, I. & Frier, B. (2001). Symptoms of hypoglycaemia in people with diabetes. Diabetic Medicine, 18, 690{705. 20 McCance, D.R., Ritchie, C.M. & Kennedy, L. (1988). Is hba1 measurement super uous in niddm? Diabetes Care, 11, 512{514. 20 McCowen, K.C., Malhotra, A. & Bistrian, B.R. (2001). Stress-induced hyperglycemia. Critical care clinics, 17, 107{124. 20 McMahon, M.M. & Bistrian, B.R. (1995). Host defenses and susceptibility to infection in patients with diabetes mellitus. Infectious disease clinics of North America, 9, 1{9. 20 214 REFERENCES Mendes, R., Ramos, M. & Stoneham, A. (1998). Mesoscopic modelling of laser ablation. Thermophysics & Aeromechanics, 5, 223{223. 42 Miller, J.C. (1998). Laser ablation and desorption. Academic Press. 36 Miller, S.E. (1969). Integrated optics: An introduction. Bell Labs Technical Journal, 48, 2059{2069. 10 Millon, E., Perri�ere, J., Defourneau, R., Defourneau, D., Albert, O. & Etchepare, J. (2003). Femtosecond pulsed-laser deposition of batio3. Applied Physics A, 77, 73{80. 38 Mohamed Kamari, H., Azlan, M. & Shafinas, S. (2015). Optical properties of erbium doped borotellurite glass system. In Advanced Materials Re- search, vol. 1112, 7{10, Trans Tech Publ. 90 Mohan, H. (2005). The Skin, Textbook of pathology. Jaypee brothers medical publishers New Delhi. xvi, 30, 31 M�uller, U., Mertes, B., Fischbacher, C., Jageman, K. & Danzer, K. (1997). Non-invasive blood glucose monitoring by means of near infrared spectroscopy: methods for improving the reliability of the calibration models. The International journal of arti�cial organs, 20, 285{290. 25 Murray, M. (2013). Femtosecond pulsed laser deposition as a novel route for nanocomposite photonic materials on silicon. University of Leeds. xvii, 65, 73 Nathan, D.M. (1993). Long-term complications of diabetes mellitus. New Eng- land Journal of Medicine, 328, 1676{1685. 23 Nemes, Z., Dietz, R., L�uth, J., Gomba, S., Hackenthal, E. & Gross, F. (1979). The pharmacological relevance of vital staining with neutral red. Experientia, 35, 1475{1476. 151 Neuman, M.R., Buck, R.P., Cosofret, V.V., Lindner, E. & Liu, C. (1994). Fabricating biomedical sensors with thin-�lm technology. IEEE Engi- neering in Medicine and Biology Magazine, 13, 409{419. 9 215 REFERENCES Newman, J.D. & Turner, A.P. (2005). Home blood glucose biosensors: a commercial perspective. Biosensors and Bioelectronics, 20, 2435{2453. 25 Nguyen, T.B. (2004). Determining rare earth dopant concentrations in optical �bres and waveguides. Ph.D. thesis, Victoria University of Technology. 106 Nolan, C.J., Damm, P. & Prentki, M. (2011). Type 2 diabetes across generations: from pathophysiology to prevention and management. The Lancet, 378, 169{181. 19 Obermaier, K., Schmelzeisen-Redeker, G., Schoemaker, M., Kl�otzer, H.M., Kirchsteiger, H., Eikmeier, H. & del Re, L. (2013). Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment. 188 Ojeda-GP, A., Schneider, C.W., D�obeli, M., Lippert, T. & Wokaun, A. (2017). Plasma plume dynamics, rebound, and recoating of the ablation target in pulsed laser deposition. Journal of Applied Physics, 121, 135306. 88 Okoshi, M., Higashikawa, K. & Hanabusa, M. (2000). Pulsed laser deposition of zno thin �lms using a femtosecond laser. Applied Surface Science, 154, 424{427. 38 Olszak, A. (2000). Lateral scanning white-light interferometer. Applied optics, 39, 3906{3913. 126 Pasqua, L., Cundari, S., Ceresa, C. & Cavaletti, G. (2009). Recent development, applications, and perspectives of mesoporous silica particles in medicine and biotechnology. Current medicinal chemistry, 16, 3054{3063. 136 Pawley, J.B. (2006). Fundamental limits in confocal microscopy. In Handbook of biological confocal microscopy, 20{42, Springer. 62 Perriere, J., Millon, E., Seiler, W., Boulmer-Leborgne, C., Craciun, V., Albert, O., Loulergue, J. & Etchepare, J. (2002). Comparison between zno �lms grown by femtosecond and nanosecond laser ablation. Journal of Applied Physics, 91, 690{696. 38 216 REFERENCES Perry, M., Stuart, B., Banks, P., Feit, M., Yanovsky, V. & Rubenchik, A. (1999). Ultrashort-pulse laser machining of dielectric materials. Journal of applied physics, 85, 6803{6810. 12, 37, 39 phe-culture collections (2011). Culture collections. https://www. phe-culturecollections.org.uk/technical/ccp/cellcounting.aspx, (Accessed on 12/08/2017). xxiii, xxiv, 142, 143, 144 Phipps, C. (2007). Laser ablation and its applications, vol. 129. Springer. 38 Pickup, J.C. & Williams, G. (1997). Textbook of diabetes. Vol. 2 . Blackwell Science. 22, 23 Piliarik, M., Homola, J., Man�kov�a, Z. & �Ctyrok�y, J. (2003). Surface plasmon resonance sensor based on a single-mode polarization-maintaining optical �ber. Sensors and Actuators B: Chemical , 90, 236{242. 8 Potts, R.O., A Tamada, J. & J Tierney, M. (2002). Glucose monitoring by reverse iontophoresis. Diabetes/metabolism research and reviews, 18. 27 Prasad, P.N. (2004). Introduction to biophotonics. John Wiley & Sons. 5 Pronko, P. & Pan, X. (2001). Ultrafast-laser ablation creates new thin �lms. Laser focus world, 37, 103{105. 38 Pronko, P., VanRompay, P., Horvath, C., Loesel, F., Juhasz, T., Liu, X. & Mourou, G. (1998). Avalanche ionization and dielectric breakdown in silicon with ultrafast laser pulses. Physical Review B, 58, 2387. 44 Pronko, P., VanRompay, P., Zhang, Z. & Nees, J. (1999). Isotope enrichment in laser-ablation plumes and commensurately deposited thin �lms. Physical review letters, 83, 2596. 38 Quarzglas, H. (2009). Base materials. 83 Ramaswami, R., Sivarajan, K. & Sasaki, G. (2004). Optical networks: a practical perspective. Academic press, San Diego. 86 217 REFERENCES Razavi, M. & Shapiro, J.H. (2003). Wireless optical communications via diversity reception and optical preampli�cation. In Communications, 2003. ICC'03. IEEE International Conference on, vol. 3, 2262{2266, IEEE. xv, 14 Repetto, G. & Sanz, P. (1993). Neutral red uptake, cellular growth and lysosomal function: in vitro e�ects of 24 metals. Alternatives to laboratory animals: ATLA. 150 Repetto, G., Del Peso, A. & Zurita, J.L. (2008). Neutral red uptake assay for the estimation of cell viability/cytotoxicity. Nature protocols, 3, 1125. 151 Righini, G.C. & Chiappini, A. (2014). Glass optical waveguides: a review of fabrication techniques. Optical Engineering, 53, 071819{071819. xv, 10, 11, 94 Righini, G.C. & Ferrari, M. (2005). Photoluminescence of rare-earth-doped glasses. Rivista del Nuovo Cimento, 28, 1{53. 93, 99, 106, 108 Rim, K.T., Koo, K.H. & Park, J.S. (2013). Toxicological evaluations of rare earths and their health impacts to workers: a literature review. Safety and health at work, 4, 12{26. 155 Ristoscu, C., Mihailescu, I.N., Velegrakis, M., Massaouti, M., Klini, A. & Fotakis, C. (2003). Optical emission spectroscopy and time-of- ight investigations of plasmas generated from aln targets in cases of pulsed laser deposition with sub-ps and ns ultraviolet laser pulses. Journal of applied physics, 93, 2244{2250. 38 Rivera, V., Rodriguez, E., Chillcce, E., Cesar, C. & Barbosa, L. (2007). Waveguide produced by �ber on glass method using er 3+-doped tellurite glass. Journal of non-crystalline solids, 353, 339{343. 47 Rode, A.V., Luther-Davies, B. & Gamaly, E.G. (1999). Ultrafast ablation with high-pulse-rate lasers. part ii: Experiments on laser deposition of amorphous carbon �lms. Journal of Applied Physics, 85, 4222{4230. 12, 37 Rosmawati, S., Sidek, H., Zainal, A. & Zobir, H.M. (2007). Ir and uv spectral studies of zinc tellurite glasses. Journal of Applied Sciences, 7, 3051{ 3056. 90 218 REFERENCES Rozmus, W. & Tikhonchuk, V. (1990). Skin e�ect and interaction of short laser pulses with dense plasmas. Physical Review A, 42, 7401. 41 Saha, S., Arya, S.K., Singh, S., Sreenivas, K., Malhotra, B. & Gupta, V. (2009). Nanoporous cerium oxide thin �lm for glucose biosensor. Biosensors and Bioelectronics, 24, 2040{2045. 38 Sakota, D. & Takatani, S. (2012). Quantitative analysis of optical properties of owing blood using a photon-cell interactive monte carlo code: e�ects of red blood cells' orientation on light scattering. Journal of biomedical optics, 17, 0570071{05700712. 176 Sapriel, J. (1979). Acousto-optics. Wiley New York. 75 Sato, T., Funamori, N. & Yagi, T. (2011). Helium penetrates into silica glass and reduces its compressibility. Nature communications, 2, 345. 54 Sauer, M., Hofkens, J. et al. (2010). Handbook of uorescence spectroscopy and imaging: from ensemble to single molecules. John Wiley & Sons. xv, 16 Savelii, I., El Hamzaoui, H., Bigot, L., Bouwmans, G., Fsaifes, I., Capoen, B. & Bouazaoui, M. (2016). Nanostructuring an erbium local environment inside sol{gel silica glasses: toward e�cient erbium optical �ber lasers. Laser Physics Letters, 13, 025108. 93, 112 Scheen, A. (2003). Pathophysiology of type 2 diabetes. Acta Clinica Belgica, 58, 335{341. 22 Scheen, A. & Lefebvre, P. (1992). Assessment of insulin resistance in vivo: application to the study of type 2 diabetes. Hormone Research in Paediatrics, 38, 19{27. 22 Schmitz, H., Norkus, V., Hess, N. & Bousack, H. (2009). The infrared sensilla in the beetle melanophila acuminata as model for new infrared sensors. In Proc. SPIE, Bioeng. Bioinspired Syst. IV , vol. 7365, 73650A{73650A. 126 219 REFERENCES Scudiero, D.A., Shoemaker, R.H., Paull, K.D., Monks, A., Tierney, S., Nofziger, T.H., Currens, M.J., Seniff, D. & Boyd, M.R. (1988). Evaluation of a soluble tetrazolium/formazan assay for cell growth and drug sensitivity in culture using human and other tumor cell lines. Cancer research, 48, 4827{4833. 152 Senior, J.M. & Jamro, M.Y. (2009). Optical �ber communications: principles and practice. Pearson Education. 13 Seshan, K. (2012). Handbook of thin �lm deposition. William Andrew. 116 Shaw, L., Cole, B., Thielen, P., Sanghera, J. & Aggarwal, I. (2001). Mid-wave ir and long-wave ir laser potential of rare-earth doped chalcogenide glass �ber. IEEE Journal of Quantum Electronics, 37, 1127{1137. 197 Shen, S., Richards, B. & Jha, A. (2006). Enhancement in pump inversion e�ciency at 980 nm in er3+, er3+/eu3+ and er3+/ce3+ doped tellurite glass �bers. Opt. Express, 14, 5050{5054. 47 Shim, M., Shi Kam, N.W., Chen, R.J., Li, Y. & Dai, H. (2002). Functionalization of carbon nanotubes for biocompatibility and biomolecular recognition. Nano Letters, 2, 285{288. 136 Shukla, R., Bansal, V., Chaudhary, M., Basu, A., Bhonde, R.R. & Sastry, M. (2005). Biocompatibility of gold nanoparticles and their endocytotic fate inside the cellular compartment: a microscopic overview. Langmuir, 21, 10644{10654. 136 Sidek, H., Rosmawati, S., Talib, Z., Halimah, M. & Daud, W. (2009). Synthesis and optical properties of zno-teo 2 glass system. American Journal of Applied Sciences, 6, 1489. 90 Sokolowski-Tinten, K., Bialkowski, J., Cavalleri, A., von der Linde, D., Oparin, A., Meyer-ter Vehn, J. & Anisimov, S. (1998). Transient states of matter during short pulse laser ablation. Physical Review Letters, 81, 224. 40 220 REFERENCES Solehmainen, K., Kapulainen, M., Heimala, P. & Polamo, K. (2004). Erbium-doped waveguides fabricated with atomic layer deposition method. IEEE Photonics Technology Letters, 16, 194{196. 62 Song, W., Zhang, J., Guo, J., Zhang, J., Ding, F., Li, L. & Sun, Z. (2010). Role of the dissolved zinc ion and reactive oxygen species in cytotoxicity of zno nanoparticles. Toxicology letters, 199, 389{397. 155 Sosman, R.B. (1965). Phases of silica. 12 Stelzer, E.H. (2000). Practical limits to resolution in uorescence light microscopy. In Imaging Neurons, CSH Laboratory Press, New York. 62 Strickler, S. & Berg, R.A. (1962). Relationship between absorption intensity and uorescence lifetime of molecules. The Journal of chemical physics, 37, 814{822. 29 Stuart, B.C., Feit, M.D., Herman, S., Rubenchik, A., Shore, B. & Perry, M. (1996). Nanosecond-to-femtosecond laser-induced breakdown in dielectrics. Physical review B, 53, 1749. 43 Sudrie, L., Couairon, A., Franco, M., Lamouroux, B., Prade, B., Tzortzakis, S. & Mysyrowicz, A. (2002). Femtosecond laser-induced damage and �lamentary propagation in fused silica. Physical Review Letters, 89, 186601. 80 Thyagarajan, K. (2002). Linear and nonlinear propagation e�ects in optical �bers. In Optical Solitons, 33{70, Springer. 161 Tien, P. (1971). Light waves in thin �lms and integrated optics. Applied optics, 10, 2395{2413. 69 Tierney, M.J., Tamada, J.A., Potts, R.O., Eastman, R.C., Pitzer, K., Ackerman, N.R. & Fermi, S.J. (2000). The glucowatch R biographer: a frequent, automatic and noninvasive glucose monitor. 28 Tong, X.C. (2014). Characterization methodologies of optical waveguides. In Advanced Materials for Integrated Optical Waveguides, 53{102, Springer. 86 221 REFERENCES Troy, T.L. & Thennadil, S.N. (2001). Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm. Journal of biomedical optics, 6, 167{176. 163 Turner, A.P. (2013). Biosensors: sense and sensibility. Chemical Society Re- views, 42, 3184{3196. 6 Ulrich, R. & Torge, R. (1973). Measurement of thin �lm parameters with a prism coupler. Applied Optics, 12, 2901{2908. 69 Van Grieken, R. & Markowicz, A. (2001). Handbook of X-ray Spectrometry. CRC Press. 67 van Meerloo, J., Kaspers, G.J. & Cloos, J. (2011). Cell sensitivity assays: the mtt assay. Cancer cell culture: methods and protocols, 237{245. 149 Vashist, S.K. (2012). Non-invasive glucose monitoring technology in diabetes management: A review. Analytica chimica acta, 750, 16{27. 26, 27 Vernon-Parry, K. (2000). Scanning electron microscopy: an introduction. III- Vs Review, 13, 40 { 44. 65 Vidhya, K., Sudhir, R. & Mohan, V. (2004). Continuous glucose monitoring system{useful but expensive tool in management of diabetes. The Journal of the Association of Physicians of India, 52, 587{90. 24 Von der Linde, D. & Sch�uler, H. (1996). Breakdown threshold and plasma formation in femtosecond laser{solid interaction. JOSA B, 13, 216{222. 40 Von der Linde, D. & Sokolowski-Tinten, K. (2000). The physical mechanisms of short-pulse laser ablation. Applied Surface Science, 154, 1{10. 38 Waldron-Lynch, F. & Herold, K.C. (2011). Immunomodulatory therapy to preserve pancreatic �-cell function in type 1 diabetes. Nature reviews Drug discovery, 10, 439{452. xv, 22 Wan, J., Ling, Y., Sun, Q. & Wang, X. (1998). Role of codopant oxygen in erbium-doped silicon. Physical Review B, 58, 10415. 83 222 REFERENCES Wang, J. (2008). Electrochemical glucose biosensors. Chemical reviews, 108, 814{825. 25 Waters, P. (2008). Stress analysis and mechanical characterization of thin �lms for microelectronics and MEMS applications. University of South Florida. xxiii, 127, 128 Wentholt, I., Hoekstra, J., Zwart, A. & DeVries, J. (2005). Pendra goes dutch: lessons for the ce mark in europe. Diabetologia, 48, 1055{1058. 28 Wiederhorn, S.M. (1969). Fracture surface energy of glass. Journal of the American Ceramic Society, 52, 99{105. xxvii, 116, 118 Wiersma, D.S. (2008). The physics and applications of random lasers. Nature physics, 4, 359. 159 Winckler, J. (1974). Vital staining of lysosomes and other cell organelles of the rat with neutral red (author's transl). Progress in histochemistry and cyto- chemistry, 6, 1. 151 Wu, R., Myers, J.D., Myers, M.J. & Rapp, C. (2003). Fluorescence lifetime and 980 nm pump energy transfer dynamics in erbium and ytterbium co-doped phosphate laser glasses. In Proceedings of SPIE, vol. 4968, 11{17. xxvii, 58, 107 Xu, J. & Stroud, R. (1992). Acousto-optic devices: principles, design, and applications, vol. 12. Wiley-Interscience. 75 Yan, Y., Faber, A.J. & De Waal, H. (1995). Luminescence quenching by oh groups in highly er-doped phosphate glasses. Journal of Non-Crystalline Solids, 181, 283{290. 97 Yin, L., Ning, H., Turkdogan, S., Liu, Z., Nichols, P.L. & Ning, C. (2012). Long lifetime, high density single-crystal erbium compound nanowires as a high optical gain material. Applied Physics Letters, 100, 241905. 104 Yki-J�arvinen, H. (1994). Pathogenesis of non-insulin-dependent diabetes mellitus. The Lancet, 343, 91{95. 20 223 REFERENCES Yu, T., Malugin, A. & Ghandehari, H. (2011). Impact of silica nanoparticle design on cellular toxicity and hemolytic activity. ACS nano, 5, 5717{5728. 136 Zammitt, N.N. & Frier, B.M. (2005). Hypoglycemia in type 2 diabetes. Diabetes care, 28, 2948{2961. 20 Zergioti, I., Mailis, S., Vainos, N., Ikiades, A., Grigoropoulos, C. & Fotakis, C. (1999). Microprinting and microetching of di�ractive structures using ultrashort laser pulses. Applied surface science, 138, 82{86. 38 Zergioti, I., Papazoglou, D., Karaiskou, A., Fotakis, C., Gamaly, E. & Rode, A. (2003). A comparative schlieren imaging study between ns and sub-ps laser forward transfer of cr. Applied Surface Science, 208, 177{180. 38 Zhang, Z., Grattan, K., Palmer, A., Meggitt, B. & Sun, T. (1997). Fluorescence decay-time characteristics of erbium-doped optical �ber at elevated temperatures. Review of scienti�c instruments, 68, 2764{2766. 106, 108 Zhang, Z., VanRompay, P., Nees, J., Clarke, R., Pan, X. & Pronko, P. (2000). Nitride �lm deposition by femtosecond and nanosecond laser ablation in low-pressure nitrogen discharge gas. Applied surface science, 154, 165{171. 38 Zhao, Z. (2012). Pulsed laser deposition and characterisation of rare earth doped glass-polymer optical materials. University of Leeds. xxviii, 119, 120 Zhao, Z., Jose, G., Steenson, P., Bamiedakis, N., Penty, R.V., White, I.H. & Jha, A. (2011). Tellurite glass thin �lms on silica and polymer using uv (193 nm) pulsed laser ablation. Journal of Physics D: Applied Physics, 44, 095501. 47 Zhao, Z., Jose, G., Fernandez, T.T., Comyn, T.P., Irannejad, M., Steenson, P., Harrington, J.P., Ward, M., Bamiedakis, N., Penty, R.V. et al. (2012). Active glass{polymer superlattice structure for photonic integration. Nanotechnology, 23, 225302. xxii, xxviii, 116, 119, 120, 121, 122, 123, 125 224 REFERENCES Zhong, N., Zhu, X., Liao, Q., Wang, Y., Chen, R. & Sun, Y. (2013). E�ects of surface roughness on optical properties and sensitivity of �ber-optic evanescent wave sensors. Applied optics, 52, 3937{3945. 80"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.733565"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["Seamatics","Non invasive sensor","MAST STC"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/19145/1/thesis.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Erbium (Er3+) ions have been extensively used in the field of integrated photonics due to it's characteristic fluorescence properties which can be used to amplify the optical signal in fibre based optical communication systems. In this study, novel materials were developed by doping Er3+ ions in glass polymer (GP) superlattice coated on a silicon substrate to investigate its application as an infrared (IR) sensor. The conventional IR detectors are classified as thermal detector and photonic detectors. The conventional photonic detector has better sensing capabilities however, they are required to be cooled down to 77 K for sensing IR radiations. Thus the current requirement is to develop uncooled IR detector which can sense minute changes in the temperature. The initial studies show that GP superlattice coated tipless cantilevers are able to sense changes in temperature with a resolution of 2 mK per nm deflection of the cantilever. The second part of the study was to dope Er3+ ions with or without Ytterbium (Yb3+) ions as a co-dopant in fused silica for glucose sensing. The fabrication was done using the pulsed laser deposition method which is a well-established technique for manufacturing nanoengineered thin films. The parameters for fabrication of optical glucose sensor were altered to assess the impact of different parameters such as chamber oxygen pressure, deposition time, Er3+ and Yb3+ ions concentrations on structural and fluorescence characteristics of thin films. The spectroscopic characterisation revealed that the low doping (0.25 mol %) concentration of Er3+ ions in the thin films results in longer fluorescence lifetime of up to 12.4 ms while the doping of Er3+ ion in fused silica has been achieved to 2.4 micron depth. The fabricated thin films were also characterized using techniques such as absorption spectroscopy, fluorescence spectroscopy, prism coupling, energy dispersive x-ray mapping using transmission electron microscopy. The thin films with longer fluorescence lifetime were selected for glucose monitoring device development. Poor management of diabetes mellitus can result in various complications such as cardiovascular disease, retinopathy, neuropathy and limb amputations. Diabetes control and complication trial highlighted that, with better glycaemic control resulted in reduced complications due to diabetes. The current techniques available to measure glucose levels are invasive in nature. Presently there is a desperate need for non-invasive sensing technology which is considered as holy grail for glycaemic control. The glucose sensing capabilities of the Er3+ ions doped fused silica was tested using in-vitro glucose measurement in aqueous solutions, blood samples, and intralipids solution. A laboratory bench prototype was developed for a pilot clinical study on people with type 1 diabetes. The change in fluorescence lifetime due to change in glucose concentrations was analysed. The calibrated values were then correlated with the actual glucose reading from finger prick handheld glucose meter and invasive continuous glucose monitor (ICGM). The results were analysed using clarke error grid (CEG) analysis which is a standard statistical analysis tool to assess the accuracy of the device. The next stage of the development includes fabricating a new batch of the photonics chips which has shown the glucose sensing capabilities and thereafter carrying out in-vitro testing as well as carry out the second stage of clinical trials."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Ultrafast pulsed laser plasma fabrication of erbium doped thin film sensors"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jose, Gin","Saha, Sikha","Grant, Peter","Ajjan, Ramzi"],"dc:contributor.sponsor":["EPSRC","Glucosense diagnostics","NIHR i4i","DSTL"],"dc:creator":["Kakkar, Tarun"],"dc:date":["2017-09"],"dc:date.issued":["2017-09"],"dc:description.abstract":["Erbium (Er3+) ions have been extensively used in the field of integrated photonics due to it's characteristic fluorescence properties which can be used to amplify the optical signal in fibre based optical communication systems. In this study, novel materials were developed by doping Er3+ ions in glass polymer (GP) superlattice coated on a silicon substrate to investigate its application as an infrared (IR) sensor. The conventional IR detectors are classified as thermal detector and photonic detectors. The conventional photonic detector has better sensing capabilities however, they are required to be cooled down to 77 K for sensing IR radiations. Thus the current requirement is to develop uncooled IR detector which can sense minute changes in the temperature. The initial studies show that GP superlattice coated tipless cantilevers are able to sense changes in temperature with a resolution of 2 mK per nm deflection of the cantilever. The second part of the study was to dope Er3+ ions with or without Ytterbium (Yb3+) ions as a co-dopant in fused silica for glucose sensing. The fabrication was done using the pulsed laser deposition method which is a well-established technique for manufacturing nanoengineered thin films. The parameters for fabrication of optical glucose sensor were altered to assess the impact of different parameters such as chamber oxygen pressure, deposition time, Er3+ and Yb3+ ions concentrations on structural and fluorescence characteristics of thin films. The spectroscopic characterisation revealed that the low doping (0.25 mol %) concentration of Er3+ ions in the thin films results in longer fluorescence lifetime of up to 12.4 ms while the doping of Er3+ ion in fused silica has been achieved to 2.4 micron depth. The fabricated thin films were also characterized using techniques such as absorption spectroscopy, fluorescence spectroscopy, prism coupling, energy dispersive x-ray mapping using transmission electron microscopy. The thin films with longer fluorescence lifetime were selected for glucose monitoring device development. Poor management of diabetes mellitus can result in various complications such as cardiovascular disease, retinopathy, neuropathy and limb amputations. Diabetes control and complication trial highlighted that, with better glycaemic control resulted in reduced complications due to diabetes. The current techniques available to measure glucose levels are invasive in nature. Presently there is a desperate need for non-invasive sensing technology which is considered as holy grail for glycaemic control. The glucose sensing capabilities of the Er3+ ions doped fused silica was tested using in-vitro glucose measurement in aqueous solutions, blood samples, and intralipids solution. A laboratory bench prototype was developed for a pilot clinical study on people with type 1 diabetes. The change in fluorescence lifetime due to change in glucose concentrations was analysed. The calibrated values were then correlated with the actual glucose reading from finger prick handheld glucose meter and invasive continuous glucose monitor (ICGM). The results were analysed using clarke error grid (CEG) analysis which is a standard statistical analysis tool to assess the accuracy of the device. The next stage of the development includes fabricating a new batch of the photonics chips which has shown the glucose sensing capabilities and thereafter carrying out in-vitro testing as well as carry out the second stage of clinical trials."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.733565"],"dc:identifier.grantnumber":["Seamatics","Non invasive sensor","MAST STC"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/19145/1/thesis.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Faculty of Medicine and Health (Leeds)","Leeds Institute of Genetics, Health and Therapeutics (LIGHT)","School of Chemical and Process Engineering (Leeds)","Institute for Materials Research (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/19145/"],"dc:relation.references":["References Abcam (2017). Counting cells using a hemocytometer | abcam. http: //www.abcam.com/protocols/counting-cells-using-a-haemocytometer, (Accessed on 12/08/2017). 145 Adams, A., Schinke, D. & Capio, C. (1979). An evaluation of the prism coupler for measuring the thickness and refractive index of dielectric �lms on silicon substrates. Journal of The Electrochemical Society, 126, 1539{1543. 67 Adler, A.I., Stratton, I.M., Neil, H.A.W., Yudkin, J.S., Matthews, D.R., Cull, C.A., Wright, A.D., Turner, R.C. & Holman, R.R. (2000). Association of systolic blood pressure with macrovascular and microvascular complications of type 2 diabetes (ukpds 36): prospective observational study. Bmj, 321, 412{419. 24 Ainslie, B.J. (1991). A review of the fabrication and properties of erbium-doped �bers for optical ampli�ers. Journal of Lightwave Technology, 9, 220{227. 93 Albani, J.R. (2008). Principles and applications of uorescence spectroscopy. John Wiley & Sons. xv, xxvii, 15, 16, 17, 18, 19 Alexeeva, N.V. (2011). Characterization of skin tissue heterogeneity with near- infrared microspectroscopy and its e�ects on noninvasive measurements of glu- cose. The University of Iowa. 26 201 REFERENCES Allen, R. & David, G. (1969). The zeiss-nomarski di�erential interference equipment for transmitted-light microscopy. Zeitschrift fur wissenschaftliche Mikroskopie und mikroskopische Technik, 69, 193{221. 61 Amerov, A.K., Chen, J. & Arnold, M.A. (2004). Molar absorptivities of glucose and other biological molecules in aqueous solutions over the �rst overtone and combination regions of the near-infrared spectrum. Applied spec- troscopy, 58, 1195{1204. xvi, 28, 30, 31, 159, 161, 162 Anderson, J.M. & Shive, M.S. (2012). Biodegradation and biocompatibility of pla and plga microspheres. Advanced drug delivery reviews, 64, 72{82. 136 Anderson, R.R. & Parrish, J.A. (1981). The optics of human skin. Journal of investigative dermatology, 77, 13{19. xvi, 30, 32 Astles, J.R., Sedor, F.A. & Toffaletti, J.G. (1996). Evaluation of the ysi 2300 glucose analyzer: algorithm-corrected results are accurate and speci�c. Clinical biochemistry, 29, 27{31. 24 Ba, L.A., D�oring, M., Jamier, V. & Jacob, C. (2010). Tellurium: an element with great biological potency and potential. Organic & biomolecular chemistry, 8, 4203{4216. 154 Babich, H. & Borenfreund, E. (1990). Applications of the neutral red cytotoxicity assay to in vitro toxicology. Alternatives to laboratory animals: ATLA. 150 Balling, P. & Schou, J. (2013). Femtosecond-laser ablation dynamics of dielectrics: basics and applications for thin �lms. Reports on Progress in Physics, 76, 036502. 84 Banks, P., Dinh, L., Stuart, B., Feit, M., Komashko, A., Rubenchik, A., Perry, M. & McLean, W. (1999). Short-pulse laser deposition of diamond-like carbon thin �lms. Applied Physics A, 69, S347{S353. 38 202 REFERENCES Beletic, J.W., Blank, R., Gulbransen, D., Lee, D., Loose, M., Piquette, E.C., Sprafke, T., Tennant, W.E., Zandian, M. & Zino, J. (2008). Teledyne imaging sensors: Infrared imaging technologies for astronomy & civil space. In Proc. SPIE, vol. 7021. 9 Berezin, M.Y. & Achilefu, S. (2010). Fluorescence lifetime measurements and biological imaging. Chemical reviews, 110, 2641{2684. 160 Berneschi, S., Nunzi Conti, G., B�any�asz, I., Watterich, A., Khanh, N., Fried, M., P�aszti, F., Brenci, M., Pelli, S. & Righini, G. (2007). Ion beam irradiated channel waveguides in er 3+-doped tellurite glass. Applied physics letters, 90, 121136. 47 Bharate, J.B., Batarseh, Y.S., Wani, A., Sharma, S., Vishwakarma, R.A., Kaddoumi, A., Kumar, A. & Bharate, S.B. (2015). Synthesis and p-glycoprotein induction activity of colupulone analogs. Organic & biomolecu- lar chemistry, 13, 5488{5496. 153 Bistrian, B.R. (2001). Hyperglycemia and infection: which is the chicken and which is the egg? Journal of Parenteral and Enteral Nutrition, 25, 180{181. 20 Bland, J.M. & Altman, D.G. (2007). Agreement between methods of measurement with multiple observations per individual. Journal of biopharmaceu- tical statistics, 17, 571{582. 187 Bloomfield, P. (2004). Fourier analysis of time series: an introduction. John Wiley & Sons. 88 Borenfreund, E. & Puerner, J.A. (1985). A simple quantitative procedure using monolayer cultures for cytotoxicity assays (htd/nr-90). Methods in Cell Science, 9, 7{9. 150 Bradley, J.D. (2017). Rare earth doped light emitting thin �lm materials for silicon photonics. In Meeting Abstracts, 17, 1013{1013, The Electrochemical Society. 5 203 REFERENCES Briscoe, V.J. & Davis, S.N. (2006). Hypoglycemia in type 1 and type 2 diabetes: physiology, pathophysiology, and management. Clinical Diabetes, 24, 115{121. 20 Br�uckner, R. (1970). Properties and structure of vitreous silica. i. Journal of non-crystalline solids, 5, 123{175. 13 Bulgakova, N., Stoian, R., Rosenfeld, A., Hertel, I. & Campbell, E. (2004). Electronic transport and consequences for material removal in ultrafast pulsed laser ablation of materials. Physical Review B, 69, 054102. 44 Cao, H. & Sheehan, S.W. (2013). Applied physics: A cascade laser's random walk. Nature, 503, 200{201. 159 Carey, J. (2002). Structure of multi-oxygen-related defects in erbium-implanted silicon. Journal of Physics: Condensed Matter, 14, 8537. 83 Chandrappan, J., Murray, M., Kakkar, T., Petrik, P., Agocs, E., Zolnai, Z., Steenson, D., Jha, A. & Jose, G. (2015). Target dependent femtosecond laser plasma implantation dynamics in enabling silica for high density erbium doping. Scienti�c reports, 5, 14037. 82, 94, 112 Chen, C.Y. & Chi, S. (1993). Attenuation and uorescence characteristics of optical signals propagating in an erbium-doped �ber. IEEE photonics technol- ogy letters, 5, 1020{1022. 161 Cheney, B. (2007). Introduction to scanning electron microscopy. Materials Engineering department San Jose State University. 65 Chrisey, D.B. & Hubler, G.K. (1994). Pulsed laser deposition of thin �lms. 12, 36 Ciminelli, C., Campanella, C.M., Dell'Olio, F., Campanella, C.E. & Armenise, M.N. (2013). Label-free optical resonant sensors for biochemical applications. Progress in Quantum Electronics, 37, 51{107. 7 204 REFERENCES Clark, L.C. & Lyons, C. (1962). Electrode systems for continuous monitoring in cardiovascular surgery. Annals of the New York Academy of sciences, 102, 29{45. 6 Clarke, W.L. (2005). The original clarke error grid analysis (ega). Diabetes technology & therapeutics, 7, 776{779. 185 Clarke, W.L., Cox, D., Gonder-Frederick, L.A., Carter, W. & Pohl, S.L. (1987). Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes care, 10, 622{628. 185 Claxton, N.S., Fellers, T.J. & Davidson, M.W. (2006). Laser scanning confocal microscopy. Department of Optical Microscopy and Digital Imaging, Florida State University, Tallahassee, http://www. olympusconfocal. com/theory/LSCMIntro. pdf . 62 Clothier, R. (1990). The frame modi�ed neutral red uptake cytotoxicity test. Invittox protocol . 150 Cohen, M.L. (1977). Measurement of the thermal properties of human skin. a review. Journal of investigative dermatology, 69, 333{338. 159 Corporation, M. (2017a). Model 2010/m overview. 69 Corporation, N. (2017b). Shear amount in di�erential interference. xvi, 61 Corsi, C. (2010). History highlights and future trends of infrared sensors. Jour- nal of modern optics, 57, 1663{1686. 9 Couairon, A., Sudrie, L., Franco, M., Prade, B. & Mysyrowicz, A. (2005). Filamentation and damage in fused silica induced by tightly focused femtosecond laser pulses. Physical Review B, 71, 125435. 80 Craciun, V., Amirhaghi, S., Craciun, D., Elders, J., Gardeniers, J.G. & Boyd, I.W. (1995). E�ects of laser wavelength and uence on the growth of zno thin �lms by pulsed laser deposition. Applied surface science, 86, 99{106. 116 205 REFERENCES Cryer, P.E., Davis, S.N. & Shamoon, H. (2003). Hypoglycemia in diabetes. Diabetes care, 26, 1902{1912. 20 Cueff, S., Labb�e, C., Jambois, O., Garrido, B., Portier, X. & Rizk, R. (2011). Thickness-dependent optimization of er3+ light emission from siliconrich silicon oxide thin �lms. Nanoscale research letters, 6, 395. 76 Damiano, E.R., El-Khatib, F.H., Zheng, H., Nathan, D.M. & Russell, S.J. (2013). A comparative e�ectiveness analysis of three continuous glucose monitors. Diabetes Care, 36, 251{259. xxviii, 194 Davis, K., Agarwal, A., Tomozawa, M. & Hirao, K. (1996). Quantitative infrared spectroscopic measurement of hydroxyl concentrations in silica glass. Journal of non-crystalline solids, 203, 27{36. 13 DeFronzo, R.A. (1988). The triumvirate: �-cell, muscle, liver. a collusion responsible for niddm. Diabetes, 37, 667{687. 20 DeFronzo, R.A. (1997). Pathogenesis of type2 daiabetes: metabolic and molecular implications for identhfying diabetes genes. Diabetes reviews, 5, 177{269. 20, 23 Diego, S. (2017). Hemocytometer cell counting protocol. 141 Directive, C. (1993). 93/42/eec of 14 june 1993 concerning medical devices. 136 Directive, I.V.D. (1998). 98/79/ec. Vitro Diagnostic Medical Device Directive. 136 Douglas, A. & Teaney, D. (1988). Hand-held glucose monitor and recorder. In Engineering in Medicine and Biology Society, 1988. Proceedings of the An- nual International Conference of the IEEE, 747{748, IEEE. 24 Du, D., Liu, X., Korn, G., Squier, J. & Mourou, G. (1994). Laser-induced breakdown by impact ionization in sio2 with pulse widths from 7 ns to 150 fs. Applied physics letters, 64, 3071{3073. 44 206 REFERENCES Eason, R. (2007). Pulsed laser deposition of thin �lms: applications-led growth of functional materials. John Wiley & Sons. 12, 36, 37, 46, 116 Egerton, R.F. (2005). Physical principles of electron microscopy. Springer. 67 El Hamzaoui, H., Bigot, L., Bouwmans, G., Razdobreev, I., Bouazaoui, M. & Capoen, B. (2011). From molecular precursors in solution to microstructured optical �ber: a sol-gel polymeric route. Optical Materials Ex- press, 1, 234{242. 108 El-Mallawany, R. (1999). Tellurite glasses: Part 2. anelastic, phase separation, debye temperature and thermal properties. Materials chemistry and physics, 60, 103{131. xxvii, 116, 118 Estevez, M.C., Otte, M.A., Sepulveda, B. & Lechuga, L.M. (2014). Trends and challenges of refractometric nanoplasmonic biosensors: a review. Analytica chimica acta, 806, 55{73. 7 Fan, X., White, I.M., Shopova, S.I., Zhu, H., Suter, J.D. & Sun, Y. (2008). Sensitive optical biosensors for unlabeled targets: A review. analytica chimica acta, 620, 8{26. xv, 7, 8 Faust, C.B. (1992). Modern chemical techniques. Royal Soc. of Chemistry, Educ. Divn. xvii, 71, 72 Favennec, P., l'Haridon, H., Moutonnet, D., Salvi, M. & Gauneau, M. (1990). Optical activation of er3+ implanted in silicon by oxygen impurities. Japanese Journal of Applied Physics, 29, L524. 83 Feng, X., Tanabe, S. & Hanada, T. (2001). Hydroxyl groups in erbiumdoped germanotellurite glasses. Journal of non-crystalline solids, 281, 48{54. 91 Fischer-Hirchert, U.H. (2015). Photonic Packaging Sourcebook: Fiber-Chip Coupling for Optical Components, Basic Calculations, Modules. Springer. 86, 88, 93 Fox, S.I. (2009). Fundamentals of human physiology. McGraw-Hill. xv, 21 207 REFERENCES Gadelmawla, E., Koura, M., Maksoud, T., Elewa, I. & Soliman, H. (2002). Roughness parameters. Journal of materials processing technology, 123, 133{145. xvi, xvii, 63, 64, 65 Gal, A., Harman-Boehm, I., Naidis, E., Mayzel, Y. & Trieman, L. (2011). Validity of glucotrack R , a non-invasive glucose monitor, for variety of diabetics. Age, 1, 61. xxviii, 194 Gamaly, E.G., Rode, A.V. & Luther-Davies, B. (1999). Ultrafast ablation with high-pulse-rate lasers. part i: Theoretical considerations. Journal of Applied Physics, 85, 4213{4221. 37 Gamaly, E.G., Rode, A.V., Luther-Davies, B. & Tikhonchuk, V.T. (2002). Ablation of solids by femtosecond lasers: Ablation mechanism and ablation thresholds for metals and dielectrics. Physics of Plasmas (1994-present), 9, 949{957. 12, 36, 37 Gamaly, E.G., Rode, A.V., Uteza, O., Kolev, V., Luther-Davies, B., Bauer, T., Koch, J., Korte, F. & Chichkov, B. (2004). Control over a phase state of the laser plume ablated by femtosecond laser: Spatial pulse shaping. Journal of Applied Physics, 95, 2250{2257. 37 Gehrz, R., Becklin, E., De Pater, I., Lester, D., Roellig, T. & Woodward, C. (2009). A new window on the cosmos: The stratospheric observatory for infrared astronomy (so�a). Advances in Space Research, 44, 413{432. 9 Gepts, W. (1965). Pathologic anatomy of the pancreas in juvenile diabetes mellitus. Diabetes, 14, 619{633. 22 Giannuzzi, L.A. et al. (2006). Introduction to focused ion beams: instrumen- tation, theory, techniques and practice. Springer Science & Business Media. 66 208 REFERENCES Gierak, J., Mailly, D., Faini, G., Pelouard, J., Denk, P., Pardo, F., Marzin, J., Septier, A., Schmid, G., Ferr�e, J. et al. (2001). Nanofabrication with focused ion beams. Microelectronic Engineering, 57, 865{875. 66 Girard, S., Ouerdane, Y., Tortech, B., Marcandella, C., Robin, T., Cadier, B., Baggio, J., Paillet, P., Ferlet-Cavrois, V., Boukenter, A. et al. (2009). Radiation e�ects on ytterbium-and ytterbium/erbiumdoped double-clad optical �bers. IEEE Transactions on Nuclear Science, 56, 3293{3299. 93, 99, 112 Gonen, B., Rochman, H., Rubenstein, A., Tanega, S. & Horwitz, D. (1977). Haemoglobin a1: an indicator of the metabolic control of diabetic patients. The Lancet, 310, 734{737. 20 Grew, R.S., Ebendorff-Heidepriem, H., Veitch, P.J. & Monro, T.M. (2006). Concentration e�ects in erbium doped tellurite glass. In Optoelectronic and Microelectronic Materials and Devices, 2006 Conference on, 196{199, IEEE. 108 Griscom, D.L. (1991). Optical properties and structure of defects in silica glass. Journal of the Ceramic Society of Japan, 99, 923{942. 91 Group, D.R.S.R. et al. (1978). Photocoagulation treatment of proliferative diabetic retinopathy: the second report of diabetic retinopathy study �ndings. Ophthalmology, 85, 82{106. 23 Group, U.P.D.S. et al. (1988). Prospective diabetes study iv. characteristics of newly presenting type 2 diabetic patients: male preponderance and obesity at di�erent ages. multicenter study. Diabetic Medicine, 5, 154{159. 24 Guo, J., Keathley, P.D. & Hastings, J. (2008). Dual-mode surfaceplasmon- resonance sensors using angular interrogation. Optics letters, 33, 512{ 514. 8 Haglund, R.F., Miller, J.C., Lucatorto, T. & De Graef, M. (1997). Laser Ablation and Desorption, vol. 30. Academic Press. 12 209 REFERENCES Harman-Boehm, I., Gal, A., Raykhman, A.M., Zahn, J.D., Naidis, E. & Mayzel, Y. (2009). Noninvasive glucose monitoring: a novel approach. 26 Hart, G. (1927). The nomenclature of silica. American Mineralogist , 12, 383{ 395. 12 Harvey, J.E. (1976). Light-scattering characteristics of optical surfaces. 80 Hayashi, H., Sugimoto, N., Tanabe, S. & Ohara, S. (2006). E�ect of hydroxyl groups on erbium-doped bismuth-oxide-based glasses for �ber ampli�ers. Journal of applied physics, 99, 093105. 91 Hayashi, S. (1990). Di�erential interference microscope. US Patent 4,964,707. 61 Hetherington, G., Jack, K. & Ramsay, M. (1965). High-temperature electrolysis of vitreous silica. i. oxidation ultra-violet induced uorescence and irradiation colour. Physics and Chemistry of Glasses, 6, 6{+. 13 Hillier, T.A., Abbott, R.D. & Barrett, E.J. (1999). Hyponatremia: evaluating the correction factor for hyperglycemia. The American journal of medicine, 106, 399{403. 28 Hnizdo, E. & Vallyathan, V. (2003). Chronic obstructive pulmonary disease due to occupational exposure to silica dust: a review of epidemiological and pathological evidence. Occupational and Environmental Medicine, 60, 237{243. 136 Holman, R. & Turner, R. (1979). Maintenance of basal plasma glucose and insulin concentrations in maturity-onset diabetes. Diabetes, 28, 227{230. 20 Homola, J. (2008). Surface plasmon resonance sensors for detection of chemical and biological species. Chemical reviews, 108, 462{493. 7 Huang, M. (2003). Stress e�ects on the performance of optical waveguides. International Journal of Solids and Structures, 40, 1615{1632. 62, 74, 80 210 REFERENCES Ibrahim, M.H., Kassim, N.M., Mohammad, A.B. & Gang, S.Y. (2004a). Modelling of rib optical waveguide structure using e�ective index method. Ju- rnal Elektrika, 6, 43{49. 69 Ibrahim, M.H., Kassim, N.M., Mohammad, A.B. & Chin, M.K. (2006). Prism coupling measurement of benzocyclobutene (bcb 4024-40) polymer for optical devices application. Elektrika Journal of Electrical Engineering, 8, 13{ 16. xvii, 68, 69 Ibrahim, Y.M., Alsharaeh, E.H. & El-Shall, M.S. (2004b). Evidence for penning ionization in the generation of electronically excited states of transition metal cations by laser vaporization. The Journal of Physical Chemistry B, 108, 3959{3962. 88 ISO, E. (2008). 10993-12: 2008{biological evaluation of medical devices{part 12: Sample preparation and reference materials (iso 10993-12: 2007). German version: DIN EN ISO, 10993{10912. 136, 147, 151 ISO, I. (2009). 10993{5: 2009 biological evaluation of medical devices{part 5: Tests for in vitro cytotoxicity. International Organization for Standardization, Geneva. 136, 147, 149, 150, 152, 153 Jeng, J.H., Hsieh, C., Lan, W., Chang, M., Lin, S., Hahn, L. & Kuo, M. (1998). Cytotoxicity of sodium uoride on human oral mucosal �broblasts and its mechanisms. Cell biology and toxicology, 14, 383{389. 155 Jorgenson, R. & Yee, S. (1993). A �ber-optic chemical sensor based on surface plasmon resonance. Sensors and Actuators B: Chemical , 12, 213{220. 8 Karim, A. & Andersson, J.Y. (2013). Infrared detectors: Advances, challenges and new technologies. In IOP Conference Series: Materials Science and Engineering, vol. 51, 012001, IOP Publishing. 9, 10 Keiser, G. (2003). Optical �ber communications. Wiley Online Library. 13 Kersten, R.T. (1975). A new method for measuring refractive index and thickness of liquid and deposited solid thin �lms. Optics Communications, 13, 327{ 329. 67 211 REFERENCES Kholodkov, A. & Golant, K. (2005). Er 3+ ions luminescence in non-fused silicate glasses fabricated by spcvd. Optical materials, 27, 1178{1186. 108 Kik, P.G. (2001). Energy transfer in erbium doped optical waveguides based on silicon. Ph.D. thesis. 12, 15 Kim, I.Y., Joachim, E., Choi, H. & Kim, K. (2015). Toxicity of silica nanoparticles depends on size, dose, and cell type. Nanomedicine: Nanotech- nology, Biology and Medicine, 11, 1407{1416. 136 Kitamura, R., Pilon, L. & Jonasz, M. (2007). Optical constants of silica glass from extreme ultraviolet to far infrared at near room temperature. Applied optics, 46, 8118{8133. 12 Klarh�ofer, M., Csapo, B., Balassy, C., Szeles, J. & Moser, E. (2001). High-resolution blood ow velocity measurements in the human �nger. Mag- netic resonance in medicine, 45, 716{719. 170 Klocke, D., Schmitz, A., Soltner, H., Bousack, H. & Schmitz, H. (2011). Infrared receptors in pyrophilous (\\�re loving\") insects as model for new un-cooled infrared sensors. Beilstein journal of nanotechnology, 2, 186. 126 Koughia, C. & Kasap, S.O. (2008). Excitation di�usion in gegase and gegas glasses heavily doped with er 3+. Optics express, 16, 7709{7714. 106 Kovatchev, B., Anderson, S., Heinemann, L. & Clarke, W. (2008). Comparison of the numerical and clinical accuracy of four continuous glucose monitors. Diabetes care, 31, 1160{1164. xxviii, 194 Landau, L.D., Bell, J., Kearsley, M., Pitaevskii, L., Lifshitz, E. & Sykes, J. (2013). Electrodynamics of continuous media, vol. 8. elsevier. 41 Lang, W. (1982). Nomarski di�erential interference-contrast microscopy. Oberkochen, Carl Zeiss. 61 Latif, A. (2000). Nanofabrication using focused ion beam. Ph.D. thesis, University of Cambridge. 66 212 REFERENCES Lawson, W., Nielsen, S., Putley, E. & Young, A. (1959). Preparation and properties of hgte and mixed crystals of hgte-cdte. Journal of Physics and Chemistry of Solids, 9, 325{329. 9 LeMieux, M.C., McConney, M.E., Lin, Y.H., Singamaneni, S., Jiang, H., Bunning, T.J. & Tsukruk, V.V. (2006). Polymeric nanolayers as actuators for ultrasensitive thermal bimorphs. Nano letters, 6, 730{734. 132 Liedberg, B., Nylander, C. & Lunstr�om, I. (1983). Surface plasmon resonance for gas detection and biosensing. Sensors and actuators, 4, 299{304. 8 Liu, Y., L�u, C., Li, M., Zhang, L. & Yang, B. (2008). High refractive index organic{inorganic hybrid coatings with tio 2 nanocrystals. Colloids and Surfaces A: Physicochemical and Engineering Aspects, 328, 67{72. 67 Lorazo, P., Lewis, L.J. & Meunier, M. (2003). Short-pulse laser ablation of solids: from phase explosion to fragmentation. Physical review letters, 91, 225502. 40 Lourenc�o, M., Milo�sevi�c, M., Gorin, A., Gwilliam, R. & Homewood, K. (2016). Super-enhancement of 1.54 �m emission from erbium codoped with oxygen in silicon-on-insulator. Scienti�c reports, 5. 83 Luther-Davies, B. & Gamali�� (????). Matter in ultrastrong laser �elds. 41 Ma, H., Shieh, K.J., Qiao, T.X. & Cherng, S. (2006). Transmission electron microscopy (tem) and scanning electron microscopy (sem). Nature and Science, 14. 67 Maciel, E., Bolzan, R., Braga, A. & Rocha, J. (2000). Diphenyl diselenide and diphenyl ditelluride di�erentially a�ect �-aminolevulinate dehydratase from liver, kidney, and brain of mice. Journal of Biochemical and Molecular Toxicology, 14, 310{319. 154 213 REFERENCES Maier, J.S., Walker, S.A., Fantini, S., Franceschini, M.A. & Gratton, E. (1994). Possible correlation between blood glucose concentration and the reduced scattering coe�cient of tissues in the near infrared. Optics letters, 19, 2062{2064. 29, 33, 159 Mailis, S., Zergioti, I., Koundourakis, G., Ikiades, A., Patentalaki, A., Papakonstantinou, P., Vainos, N.A. & Fotakis, C. (1999). Etching and printing of di�ractive optical microstructures by a femtosecond excimer laser. Applied optics, 38, 2301{2308. 38 Maine, P., Strickland, D., Bado, P., Pessot, M. & Mourou, G. (1988). Generation of ultrahigh peak power pulses by chirped pulse ampli�cation. IEEE Journal of Quantum electronics, 24, 398{403. 49 Matsuoka, M. & Tohno, S.i. (1995). 1.54 �m photoluminescence of in situ erbium-oxygen co-doped silicon �lms grown by ion-beam epitaxy. Journal of applied physics, 78, 2751{2757. 83 Mattarelli, M., Montagna, M., Zampedri, L., Chiasera, A., Ferrari, M., Righini, G., Fortes, L., Gonc�alves, M., Santos, L. & Almeida, R. (2005). Self-absorption and radiation trapping in er3+-doped teo2-based glasses. EPL (Europhysics Letters), 71, 394. 106 McAulay, V., Deary, I. & Frier, B. (2001). Symptoms of hypoglycaemia in people with diabetes. Diabetic Medicine, 18, 690{705. 20 McCance, D.R., Ritchie, C.M. & Kennedy, L. (1988). Is hba1 measurement super uous in niddm? Diabetes Care, 11, 512{514. 20 McCowen, K.C., Malhotra, A. & Bistrian, B.R. (2001). Stress-induced hyperglycemia. Critical care clinics, 17, 107{124. 20 McMahon, M.M. & Bistrian, B.R. (1995). Host defenses and susceptibility to infection in patients with diabetes mellitus. Infectious disease clinics of North America, 9, 1{9. 20 214 REFERENCES Mendes, R., Ramos, M. & Stoneham, A. (1998). Mesoscopic modelling of laser ablation. Thermophysics & Aeromechanics, 5, 223{223. 42 Miller, J.C. (1998). Laser ablation and desorption. Academic Press. 36 Miller, S.E. (1969). Integrated optics: An introduction. Bell Labs Technical Journal, 48, 2059{2069. 10 Millon, E., Perri�ere, J., Defourneau, R., Defourneau, D., Albert, O. & Etchepare, J. (2003). Femtosecond pulsed-laser deposition of batio3. Applied Physics A, 77, 73{80. 38 Mohamed Kamari, H., Azlan, M. & Shafinas, S. (2015). Optical properties of erbium doped borotellurite glass system. In Advanced Materials Re- search, vol. 1112, 7{10, Trans Tech Publ. 90 Mohan, H. (2005). The Skin, Textbook of pathology. Jaypee brothers medical publishers New Delhi. xvi, 30, 31 M�uller, U., Mertes, B., Fischbacher, C., Jageman, K. & Danzer, K. (1997). Non-invasive blood glucose monitoring by means of near infrared spectroscopy: methods for improving the reliability of the calibration models. The International journal of arti�cial organs, 20, 285{290. 25 Murray, M. (2013). Femtosecond pulsed laser deposition as a novel route for nanocomposite photonic materials on silicon. University of Leeds. xvii, 65, 73 Nathan, D.M. (1993). Long-term complications of diabetes mellitus. New Eng- land Journal of Medicine, 328, 1676{1685. 23 Nemes, Z., Dietz, R., L�uth, J., Gomba, S., Hackenthal, E. & Gross, F. (1979). The pharmacological relevance of vital staining with neutral red. Experientia, 35, 1475{1476. 151 Neuman, M.R., Buck, R.P., Cosofret, V.V., Lindner, E. & Liu, C. (1994). Fabricating biomedical sensors with thin-�lm technology. IEEE Engi- neering in Medicine and Biology Magazine, 13, 409{419. 9 215 REFERENCES Newman, J.D. & Turner, A.P. (2005). Home blood glucose biosensors: a commercial perspective. Biosensors and Bioelectronics, 20, 2435{2453. 25 Nguyen, T.B. (2004). Determining rare earth dopant concentrations in optical �bres and waveguides. Ph.D. thesis, Victoria University of Technology. 106 Nolan, C.J., Damm, P. & Prentki, M. (2011). Type 2 diabetes across generations: from pathophysiology to prevention and management. The Lancet, 378, 169{181. 19 Obermaier, K., Schmelzeisen-Redeker, G., Schoemaker, M., Kl�otzer, H.M., Kirchsteiger, H., Eikmeier, H. & del Re, L. (2013). Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment. 188 Ojeda-GP, A., Schneider, C.W., D�obeli, M., Lippert, T. & Wokaun, A. (2017). Plasma plume dynamics, rebound, and recoating of the ablation target in pulsed laser deposition. Journal of Applied Physics, 121, 135306. 88 Okoshi, M., Higashikawa, K. & Hanabusa, M. (2000). Pulsed laser deposition of zno thin �lms using a femtosecond laser. Applied Surface Science, 154, 424{427. 38 Olszak, A. (2000). Lateral scanning white-light interferometer. Applied optics, 39, 3906{3913. 126 Pasqua, L., Cundari, S., Ceresa, C. & Cavaletti, G. (2009). Recent development, applications, and perspectives of mesoporous silica particles in medicine and biotechnology. Current medicinal chemistry, 16, 3054{3063. 136 Pawley, J.B. (2006). Fundamental limits in confocal microscopy. In Handbook of biological confocal microscopy, 20{42, Springer. 62 Perriere, J., Millon, E., Seiler, W., Boulmer-Leborgne, C., Craciun, V., Albert, O., Loulergue, J. & Etchepare, J. (2002). Comparison between zno �lms grown by femtosecond and nanosecond laser ablation. Journal of Applied Physics, 91, 690{696. 38 216 REFERENCES Perry, M., Stuart, B., Banks, P., Feit, M., Yanovsky, V. & Rubenchik, A. (1999). Ultrashort-pulse laser machining of dielectric materials. Journal of applied physics, 85, 6803{6810. 12, 37, 39 phe-culture collections (2011). Culture collections. https://www. phe-culturecollections.org.uk/technical/ccp/cellcounting.aspx, (Accessed on 12/08/2017). xxiii, xxiv, 142, 143, 144 Phipps, C. (2007). Laser ablation and its applications, vol. 129. Springer. 38 Pickup, J.C. & Williams, G. (1997). Textbook of diabetes. Vol. 2 . Blackwell Science. 22, 23 Piliarik, M., Homola, J., Man�kov�a, Z. & �Ctyrok�y, J. (2003). Surface plasmon resonance sensor based on a single-mode polarization-maintaining optical �ber. Sensors and Actuators B: Chemical , 90, 236{242. 8 Potts, R.O., A Tamada, J. & J Tierney, M. (2002). Glucose monitoring by reverse iontophoresis. Diabetes/metabolism research and reviews, 18. 27 Prasad, P.N. (2004). Introduction to biophotonics. John Wiley & Sons. 5 Pronko, P. & Pan, X. (2001). Ultrafast-laser ablation creates new thin �lms. Laser focus world, 37, 103{105. 38 Pronko, P., VanRompay, P., Horvath, C., Loesel, F., Juhasz, T., Liu, X. & Mourou, G. (1998). Avalanche ionization and dielectric breakdown in silicon with ultrafast laser pulses. Physical Review B, 58, 2387. 44 Pronko, P., VanRompay, P., Zhang, Z. & Nees, J. (1999). Isotope enrichment in laser-ablation plumes and commensurately deposited thin �lms. Physical review letters, 83, 2596. 38 Quarzglas, H. (2009). Base materials. 83 Ramaswami, R., Sivarajan, K. & Sasaki, G. (2004). Optical networks: a practical perspective. Academic press, San Diego. 86 217 REFERENCES Razavi, M. & Shapiro, J.H. (2003). Wireless optical communications via diversity reception and optical preampli�cation. In Communications, 2003. ICC'03. IEEE International Conference on, vol. 3, 2262{2266, IEEE. xv, 14 Repetto, G. & Sanz, P. (1993). Neutral red uptake, cellular growth and lysosomal function: in vitro e�ects of 24 metals. Alternatives to laboratory animals: ATLA. 150 Repetto, G., Del Peso, A. & Zurita, J.L. (2008). Neutral red uptake assay for the estimation of cell viability/cytotoxicity. Nature protocols, 3, 1125. 151 Righini, G.C. & Chiappini, A. (2014). Glass optical waveguides: a review of fabrication techniques. Optical Engineering, 53, 071819{071819. xv, 10, 11, 94 Righini, G.C. & Ferrari, M. (2005). Photoluminescence of rare-earth-doped glasses. Rivista del Nuovo Cimento, 28, 1{53. 93, 99, 106, 108 Rim, K.T., Koo, K.H. & Park, J.S. (2013). Toxicological evaluations of rare earths and their health impacts to workers: a literature review. Safety and health at work, 4, 12{26. 155 Ristoscu, C., Mihailescu, I.N., Velegrakis, M., Massaouti, M., Klini, A. & Fotakis, C. (2003). Optical emission spectroscopy and time-of- ight investigations of plasmas generated from aln targets in cases of pulsed laser deposition with sub-ps and ns ultraviolet laser pulses. Journal of applied physics, 93, 2244{2250. 38 Rivera, V., Rodriguez, E., Chillcce, E., Cesar, C. & Barbosa, L. (2007). Waveguide produced by �ber on glass method using er 3+-doped tellurite glass. Journal of non-crystalline solids, 353, 339{343. 47 Rode, A.V., Luther-Davies, B. & Gamaly, E.G. (1999). Ultrafast ablation with high-pulse-rate lasers. part ii: Experiments on laser deposition of amorphous carbon �lms. Journal of Applied Physics, 85, 4222{4230. 12, 37 Rosmawati, S., Sidek, H., Zainal, A. & Zobir, H.M. (2007). Ir and uv spectral studies of zinc tellurite glasses. Journal of Applied Sciences, 7, 3051{ 3056. 90 218 REFERENCES Rozmus, W. & Tikhonchuk, V. (1990). Skin e�ect and interaction of short laser pulses with dense plasmas. Physical Review A, 42, 7401. 41 Saha, S., Arya, S.K., Singh, S., Sreenivas, K., Malhotra, B. & Gupta, V. (2009). Nanoporous cerium oxide thin �lm for glucose biosensor. Biosensors and Bioelectronics, 24, 2040{2045. 38 Sakota, D. & Takatani, S. (2012). Quantitative analysis of optical properties of owing blood using a photon-cell interactive monte carlo code: e�ects of red blood cells' orientation on light scattering. Journal of biomedical optics, 17, 0570071{05700712. 176 Sapriel, J. (1979). Acousto-optics. Wiley New York. 75 Sato, T., Funamori, N. & Yagi, T. (2011). Helium penetrates into silica glass and reduces its compressibility. Nature communications, 2, 345. 54 Sauer, M., Hofkens, J. et al. (2010). Handbook of uorescence spectroscopy and imaging: from ensemble to single molecules. John Wiley & Sons. xv, 16 Savelii, I., El Hamzaoui, H., Bigot, L., Bouwmans, G., Fsaifes, I., Capoen, B. & Bouazaoui, M. (2016). Nanostructuring an erbium local environment inside sol{gel silica glasses: toward e�cient erbium optical �ber lasers. Laser Physics Letters, 13, 025108. 93, 112 Scheen, A. (2003). Pathophysiology of type 2 diabetes. Acta Clinica Belgica, 58, 335{341. 22 Scheen, A. & Lefebvre, P. (1992). Assessment of insulin resistance in vivo: application to the study of type 2 diabetes. Hormone Research in Paediatrics, 38, 19{27. 22 Schmitz, H., Norkus, V., Hess, N. & Bousack, H. (2009). The infrared sensilla in the beetle melanophila acuminata as model for new infrared sensors. In Proc. SPIE, Bioeng. Bioinspired Syst. IV , vol. 7365, 73650A{73650A. 126 219 REFERENCES Scudiero, D.A., Shoemaker, R.H., Paull, K.D., Monks, A., Tierney, S., Nofziger, T.H., Currens, M.J., Seniff, D. & Boyd, M.R. (1988). Evaluation of a soluble tetrazolium/formazan assay for cell growth and drug sensitivity in culture using human and other tumor cell lines. Cancer research, 48, 4827{4833. 152 Senior, J.M. & Jamro, M.Y. (2009). Optical �ber communications: principles and practice. Pearson Education. 13 Seshan, K. (2012). Handbook of thin �lm deposition. William Andrew. 116 Shaw, L., Cole, B., Thielen, P., Sanghera, J. & Aggarwal, I. (2001). Mid-wave ir and long-wave ir laser potential of rare-earth doped chalcogenide glass �ber. IEEE Journal of Quantum Electronics, 37, 1127{1137. 197 Shen, S., Richards, B. & Jha, A. (2006). Enhancement in pump inversion e�ciency at 980 nm in er3+, er3+/eu3+ and er3+/ce3+ doped tellurite glass �bers. Opt. Express, 14, 5050{5054. 47 Shim, M., Shi Kam, N.W., Chen, R.J., Li, Y. & Dai, H. (2002). Functionalization of carbon nanotubes for biocompatibility and biomolecular recognition. Nano Letters, 2, 285{288. 136 Shukla, R., Bansal, V., Chaudhary, M., Basu, A., Bhonde, R.R. & Sastry, M. (2005). Biocompatibility of gold nanoparticles and their endocytotic fate inside the cellular compartment: a microscopic overview. Langmuir, 21, 10644{10654. 136 Sidek, H., Rosmawati, S., Talib, Z., Halimah, M. & Daud, W. (2009). Synthesis and optical properties of zno-teo 2 glass system. American Journal of Applied Sciences, 6, 1489. 90 Sokolowski-Tinten, K., Bialkowski, J., Cavalleri, A., von der Linde, D., Oparin, A., Meyer-ter Vehn, J. & Anisimov, S. (1998). Transient states of matter during short pulse laser ablation. Physical Review Letters, 81, 224. 40 220 REFERENCES Solehmainen, K., Kapulainen, M., Heimala, P. & Polamo, K. (2004). Erbium-doped waveguides fabricated with atomic layer deposition method. IEEE Photonics Technology Letters, 16, 194{196. 62 Song, W., Zhang, J., Guo, J., Zhang, J., Ding, F., Li, L. & Sun, Z. (2010). Role of the dissolved zinc ion and reactive oxygen species in cytotoxicity of zno nanoparticles. Toxicology letters, 199, 389{397. 155 Sosman, R.B. (1965). Phases of silica. 12 Stelzer, E.H. (2000). Practical limits to resolution in uorescence light microscopy. In Imaging Neurons, CSH Laboratory Press, New York. 62 Strickler, S. & Berg, R.A. (1962). Relationship between absorption intensity and uorescence lifetime of molecules. The Journal of chemical physics, 37, 814{822. 29 Stuart, B.C., Feit, M.D., Herman, S., Rubenchik, A., Shore, B. & Perry, M. (1996). Nanosecond-to-femtosecond laser-induced breakdown in dielectrics. Physical review B, 53, 1749. 43 Sudrie, L., Couairon, A., Franco, M., Lamouroux, B., Prade, B., Tzortzakis, S. & Mysyrowicz, A. (2002). Femtosecond laser-induced damage and �lamentary propagation in fused silica. Physical Review Letters, 89, 186601. 80 Thyagarajan, K. (2002). Linear and nonlinear propagation e�ects in optical �bers. In Optical Solitons, 33{70, Springer. 161 Tien, P. (1971). Light waves in thin �lms and integrated optics. Applied optics, 10, 2395{2413. 69 Tierney, M.J., Tamada, J.A., Potts, R.O., Eastman, R.C., Pitzer, K., Ackerman, N.R. & Fermi, S.J. (2000). The glucowatch R biographer: a frequent, automatic and noninvasive glucose monitor. 28 Tong, X.C. (2014). Characterization methodologies of optical waveguides. In Advanced Materials for Integrated Optical Waveguides, 53{102, Springer. 86 221 REFERENCES Troy, T.L. & Thennadil, S.N. (2001). Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm. Journal of biomedical optics, 6, 167{176. 163 Turner, A.P. (2013). Biosensors: sense and sensibility. Chemical Society Re- views, 42, 3184{3196. 6 Ulrich, R. & Torge, R. (1973). Measurement of thin �lm parameters with a prism coupler. Applied Optics, 12, 2901{2908. 69 Van Grieken, R. & Markowicz, A. (2001). Handbook of X-ray Spectrometry. CRC Press. 67 van Meerloo, J., Kaspers, G.J. & Cloos, J. (2011). Cell sensitivity assays: the mtt assay. Cancer cell culture: methods and protocols, 237{245. 149 Vashist, S.K. (2012). Non-invasive glucose monitoring technology in diabetes management: A review. Analytica chimica acta, 750, 16{27. 26, 27 Vernon-Parry, K. (2000). Scanning electron microscopy: an introduction. III- Vs Review, 13, 40 { 44. 65 Vidhya, K., Sudhir, R. & Mohan, V. (2004). Continuous glucose monitoring system{useful but expensive tool in management of diabetes. The Journal of the Association of Physicians of India, 52, 587{90. 24 Von der Linde, D. & Sch�uler, H. (1996). Breakdown threshold and plasma formation in femtosecond laser{solid interaction. JOSA B, 13, 216{222. 40 Von der Linde, D. & Sokolowski-Tinten, K. (2000). The physical mechanisms of short-pulse laser ablation. Applied Surface Science, 154, 1{10. 38 Waldron-Lynch, F. & Herold, K.C. (2011). Immunomodulatory therapy to preserve pancreatic �-cell function in type 1 diabetes. Nature reviews Drug discovery, 10, 439{452. xv, 22 Wan, J., Ling, Y., Sun, Q. & Wang, X. (1998). Role of codopant oxygen in erbium-doped silicon. Physical Review B, 58, 10415. 83 222 REFERENCES Wang, J. (2008). Electrochemical glucose biosensors. Chemical reviews, 108, 814{825. 25 Waters, P. (2008). Stress analysis and mechanical characterization of thin �lms for microelectronics and MEMS applications. University of South Florida. xxiii, 127, 128 Wentholt, I., Hoekstra, J., Zwart, A. & DeVries, J. (2005). Pendra goes dutch: lessons for the ce mark in europe. Diabetologia, 48, 1055{1058. 28 Wiederhorn, S.M. (1969). Fracture surface energy of glass. Journal of the American Ceramic Society, 52, 99{105. xxvii, 116, 118 Wiersma, D.S. (2008). The physics and applications of random lasers. Nature physics, 4, 359. 159 Winckler, J. (1974). Vital staining of lysosomes and other cell organelles of the rat with neutral red (author's transl). Progress in histochemistry and cyto- chemistry, 6, 1. 151 Wu, R., Myers, J.D., Myers, M.J. & Rapp, C. (2003). Fluorescence lifetime and 980 nm pump energy transfer dynamics in erbium and ytterbium co-doped phosphate laser glasses. In Proceedings of SPIE, vol. 4968, 11{17. xxvii, 58, 107 Xu, J. & Stroud, R. (1992). Acousto-optic devices: principles, design, and applications, vol. 12. Wiley-Interscience. 75 Yan, Y., Faber, A.J. & De Waal, H. (1995). Luminescence quenching by oh groups in highly er-doped phosphate glasses. Journal of Non-Crystalline Solids, 181, 283{290. 97 Yin, L., Ning, H., Turkdogan, S., Liu, Z., Nichols, P.L. & Ning, C. (2012). Long lifetime, high density single-crystal erbium compound nanowires as a high optical gain material. Applied Physics Letters, 100, 241905. 104 Yki-J�arvinen, H. (1994). Pathogenesis of non-insulin-dependent diabetes mellitus. The Lancet, 343, 91{95. 20 223 REFERENCES Yu, T., Malugin, A. & Ghandehari, H. (2011). Impact of silica nanoparticle design on cellular toxicity and hemolytic activity. ACS nano, 5, 5717{5728. 136 Zammitt, N.N. & Frier, B.M. (2005). Hypoglycemia in type 2 diabetes. Diabetes care, 28, 2948{2961. 20 Zergioti, I., Mailis, S., Vainos, N., Ikiades, A., Grigoropoulos, C. & Fotakis, C. (1999). Microprinting and microetching of di�ractive structures using ultrashort laser pulses. Applied surface science, 138, 82{86. 38 Zergioti, I., Papazoglou, D., Karaiskou, A., Fotakis, C., Gamaly, E. & Rode, A. (2003). A comparative schlieren imaging study between ns and sub-ps laser forward transfer of cr. Applied Surface Science, 208, 177{180. 38 Zhang, Z., Grattan, K., Palmer, A., Meggitt, B. & Sun, T. (1997). Fluorescence decay-time characteristics of erbium-doped optical �ber at elevated temperatures. Review of scienti�c instruments, 68, 2764{2766. 106, 108 Zhang, Z., VanRompay, P., Nees, J., Clarke, R., Pan, X. & Pronko, P. (2000). Nitride �lm deposition by femtosecond and nanosecond laser ablation in low-pressure nitrogen discharge gas. Applied surface science, 154, 165{171. 38 Zhao, Z. (2012). Pulsed laser deposition and characterisation of rare earth doped glass-polymer optical materials. University of Leeds. xxviii, 119, 120 Zhao, Z., Jose, G., Steenson, P., Bamiedakis, N., Penty, R.V., White, I.H. & Jha, A. (2011). Tellurite glass thin �lms on silica and polymer using uv (193 nm) pulsed laser ablation. Journal of Physics D: Applied Physics, 44, 095501. 47 Zhao, Z., Jose, G., Fernandez, T.T., Comyn, T.P., Irannejad, M., Steenson, P., Harrington, J.P., Ward, M., Bamiedakis, N., Penty, R.V. et al. (2012). Active glass{polymer superlattice structure for photonic integration. Nanotechnology, 23, 225302. xxii, xxviii, 116, 119, 120, 121, 122, 123, 125 224 REFERENCES Zhong, N., Zhu, X., Liao, Q., Wang, Y., Chen, R. & Sun, Y. (2013). E�ects of surface roughness on optical properties and sensitivity of �ber-optic evanescent wave sensors. Applied optics, 52, 3937{3945. 80"],"dcterms:accessrights":["public"],"dc:title":["Ultrafast pulsed laser plasma fabrication of erbium doped thin film sensors"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:24:54Z"}