{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:19486"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:19486","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Ceramic coatings for Cervical Total Disc Replacement","abstract":"Surgical interventions for the treatment of chronic neck pain, which affects 330 million people globally, include fusion and cervical total disc replacement (CTDR). Most of the currently clinically available CTDRs designs include a metal-on-polymer (MoP) bearing. Numerous studies suggest that MoP CTDRs are associated with issues similar to those affecting other MoP joint replacement devices, including excessive wear and wear particle-related inflammation and osteolysis. The aim of this study was to investigate the biotribology of a novel metal-on-metal (MoM) design of cervical total disc replacement device in its pristine form and coated with chromium nitride or silicon nitride, in order to understand the influence of loading conditions upon the tribological performance of the implant, and to investigate biological effects of the wear debris produced by the implants. To achieve this, a series of studies were carried out. Chromium nitride and silicon nitride coatings have been characterised for their mechanical properties, chemical composition and surface finish. Whilst some of the experiments showed minor differences between the mechanical properties and adhesion of the coatings, there was no indication of significant differences between the chromium nitride and silicon nitride coated samples. Functional testing in the six-station spine wear simulator showed that MoM CTDRs produced wear volumes significantly lower than those of the commercially available MoP devices. The wear volumes were reduced further by three-fold, following testing under altered ISO-18192-1:2011 kinematics, whereby, reduced ranges of motions were applied. Whilst the silicon nitride coated CTDRs failed catastrophically early in the test, chromium nitride coated CTDRs produced an eight-fold reduction in wear volumes, when compared to the pristine devices tested under the same conditions. Investigation of potential biological effects of the particles generated in wear testing showed that that high concentrations (5-50µm3 per cell) of CoCrMo particles resulted in significant reduction of cell viability of the L929 fibroblast cells, but not the dural fibroblasts, which were used in this study. No ceramic coating particles, at any concentrations, caused significant reduction of cell viability. In summary, results presented in this thesis showed that whilst the MoM CTDR device exhibited significantly lower wear rates than those of the commercially available MoP devices, the cytotoxic wear particles could potentially lead to adverse biological reactions, particularly in patients with metal hypersensitivity, and lead to devastating consequences similar to those of failed MoM THRs. Currently, the consequences of similar failure, leading to metalosis or pseudotumour formation in the vicinity of the spinal cord are unknown. During the investigation of the ceramic coatings, it was also found that chromium nitride ceramic coating could not only lower wear rates further, but it also has the potential to reduce the cytotoxic potential of the wear particles.","abstract_html":"Surgical interventions for the treatment of chronic neck pain, which affects 330 million people globally, include fusion and cervical total disc replacement (CTDR). Most of the currently clinically available CTDRs designs include a metal-on-polymer (MoP) bearing. Numerous studies suggest that MoP CTDRs are associated with issues similar to those affecting other MoP joint replacement devices, including excessive wear and wear particle-related inflammation and osteolysis. The aim of this study was to investigate the biotribology of a novel metal-on-metal (MoM) design of cervical total disc replacement device in its pristine form and coated with chromium nitride or silicon nitride, in order to understand the influence of loading conditions upon the tribological performance of the implant, and to investigate biological effects of the wear debris produced by the implants. To achieve this, a series of studies were carried out. Chromium nitride and silicon nitride coatings have been characterised for their mechanical properties, chemical composition and surface finish. Whilst some of the experiments showed minor differences between the mechanical properties and adhesion of the coatings, there was no indication of significant differences between the chromium nitride and silicon nitride coated samples. Functional testing in the six-station spine wear simulator showed that MoM CTDRs produced wear volumes significantly lower than those of the commercially available MoP devices. The wear volumes were reduced further by three-fold, following testing under altered ISO-18192-1:2011 kinematics, whereby, reduced ranges of motions were applied. Whilst the silicon nitride coated CTDRs failed catastrophically early in the test, chromium nitride coated CTDRs produced an eight-fold reduction in wear volumes, when compared to the pristine devices tested under the same conditions. Investigation of potential biological effects of the particles generated in wear testing showed that that high concentrations (5-50µm3 per cell) of CoCrMo particles resulted in significant reduction of cell viability of the L929 fibroblast cells, but not the dural fibroblasts, which were used in this study. No ceramic coating particles, at any concentrations, caused significant reduction of cell viability. In summary, results presented in this thesis showed that whilst the MoM CTDR device exhibited significantly lower wear rates than those of the commercially available MoP devices, the cytotoxic wear particles could potentially lead to adverse biological reactions, particularly in patients with metal hypersensitivity, and lead to devastating consequences similar to those of failed MoM THRs. Currently, the consequences of similar failure, leading to metalosis or pseudotumour formation in the vicinity of the spinal cord are unknown. During the investigation of the ceramic coatings, it was also found that chromium nitride ceramic coating could not only lower wear rates further, but it also has the potential to reduce the cytotoxic potential of the wear particles.","abstract_has_math":false,"creators":["Pasko, Kinga Marta"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Tipper, Joanne L.","Hall, Richard M.","Neville, Anne"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-08","date_published":"2017-08","updated_at":"2026-11-18T22:25:23Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.736477"],"render_values":[{"text":"uk.bl.ethos.736477","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/19486/1/KM_Pasko_Thesis_2017_Final.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A19486","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tipper, Joanne L.","Hall, Richard M.","Neville, Anne"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC"]},{"key":"dc:creator","label":"Author","values":["Pasko, Kinga Marta"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-08"]},{"key":"dc:date.issued","label":"Date","values":["2017-08"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/19486/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] R. Fejer, K.O. Kyvik, J. Hartvigsen, The prevalence of neck pain in the world population: a systematic critical review of the literature, Eur. Spine J. 15 (2006) 834–848. doi:DOI 10.1007/s00586-004-0864-4. [2] T. Vos, A.D. Flaxman, M. Naghavi, M.A. AlMazroa, Z.A. Memish, Years lived with disability (YLDs) for 1160 sequelae of 289 diseases and injuries 1990-2010: a systematic analysis for the Global Burden of Disease Study 2010 (vol 380, pg 2163, 2012), Lancet. 381 (2013) 628. [3] D.G. Hoy, M. Protani, R. De, R. Buchbinder, The epidemiology of neck pain, Best Pract. Res. Clin. Rheumatol. 24 (2010) 783–792. doi:DOI 10.1016/j.berh.2011.01.019. [4] L.J. Carroll, S. Hogg-Johnson, G. van der Velde, S. Haldeman, L.W. Holm, E.J. Carragee, E.L. Hurwitz, P. Cote, M. Nordin, P.M. Peloso, J. Guzman, J.D. Cassidy, Course and prognostic factors for neck pain in the general population - Results of the bone and joint decade 2000-2010 task force on neck pain and its associated disorders, J Manip. Physiol Ther. 32 (2008) S75–S82. doi:DOI 10.1016/j.jmpt.2008.11.013. [5] J. Hill, M. Lewis, A.C. Papageorgiou, K. Dziedzic, P. Croft, Predicting persistent neck pain - A 1-year follow-up of a population cohort, Spine (Phila Pa 1976). 29 (2004) 1648–1654. doi:Doi 10.1097/01.Brs.0000132307.06321.3c. [6] P. Cote, G. van der Velde, J.D. Cassidy, L.J. Carroll, S. Hogg-Johnson, L.W. Holm, E.J. Carragee, S. Haldeman, M. Nordin, E.L. Hurwitz, J. Guzman, P.M. Peloso, The burden and determinants of neck pain in workers - Results of the bone and joint decade 2000-2010 task force on neck pain and its associated disorders, J Manip. Physiol Ther. 32 (2008) S60–S74. doi:DOI 10.1016/j.jmpt.2008.11.012. [7] S.D.M. Bot, J.M. van der Waal, C.B. Terwee, D.A.W.M. van der Windt, F.G. Schellevis, L.M. Bouter, J. Dekker, Incidence and prevalence of complaints of the neck and upper extremity in general practice, Ann Rheum Dis. 64 (2005) 118–123. doi:DOI 10.1136/ard.2003.019349. [8] P. Cote, J.D. Cassidy, L.J. Carroll, V. Kristman, The annual incidence and course of neck pain in the general population: a population-based cohort study, Pain. 112 (2004) 267–273. doi:DOI 10.1016/j.pain.2004.09.004. [9] S.D.M. Bot, J.M. van der Waal, C.B. Terwee, D.A.W.M. van der Windt, R.J.P.M. Scholten, L.M. Bouter, J. Dekker, Predictors of outcome in neck and shoulder symptoms - A cohort study in general practice, Spine (Phila Pa 1976). 30 (2005) E459–E470. doi:DOI 10.1097/01.brs.0000174279.44855.02. [10] A. Berglund, L. Alfredsson, I. Jensen, J.D. Cassidy, A. Nygren, The association between exposure to a rear-end collision and future health complaints, J Clin Epidemiol. 54 (2001) 851–856. doi:Doi 10.1016/S0895-4356(00)00369-3. [11] E.L. Hurwitz, M.S. Goldstein, H. Morgenstern, L.M. Chiang, The impact of psychosocial factors on neck pain and disability outcomes among primary care patients: Results from the UCLA Neck Pain Study, Disabil Rehabil. 28 (2006) 1319–1329. doi:Doi 10.1080/09638280600641509. [12] J.L. Kelsey, P.B. Githens, S.D. Walter, W.O. Southwick, U. Weil, T.R. Holford, A.M. Ostfeld, J.A. Calogero, T. Oconnor, A.A. White, An Epidemiological-Study of Acute Prolapsed Cervical Intervertebral-Disk, J. Bone Jt. Surgery-American Vol. 66A (1984) 907–914. [13] K.T. Palmer, K. Walker-Bone, M.J. Griffin, H. Syddall, B. Pannett, D. Coggon, C. Cooper, Prevalence and occupational associations of neck pain in the British population, Scand J Work Env. Heal. 27 (2001) 49–56. http://www.ncbi.nlm.nih.gov/pubmed/11266146. [14] J. Guzman, E.L. Hurwitz, L.J. Carroll, S. Haldeman, P. Cote, E.J. Carragee, P.M. Peloso, G. van der Velde, L.W. Holm, S. Hogg-Johnson, M. Nordin, J.D. Cassidy, A new conceptual model of neck pain - Linking onset, course, and care: The bone and joint decade 2000-2010 task force on neck pain and its associated disorders, Spine (Phila Pa 1976). 33 (2008) S14–S23. [15] L. Manchikanti, V. Singh, S. Datta, S.P. Cohen, J.A. Hirsch, Comprehensive Review of Epidemiology, Scope, and Impact of Spinal Pain, Pain Physician. 12 (2009) E35–E70. [16] B.I. Martin, R.A. Deyo, S.K. Mirza, J.A. Turner, B.A. Comstock, W. Hollingworth, S.D. Sullivan, Expenditures and health status among adults with back and neck problems, JAMA. 299 (2008) 656–664. doi:10.1001/jama.299.6.656. [17] S. Haldeman, L.J. Carroll, J.D. Cassidy, The empowerment of people with neck pain: Introduction - The bone and joint decade 2000-2010 task force on neck pain and its associated disorders, Spine (Phila Pa 1976). 33 (2008) S8–S13. [18] AAOS, Burden of Musculoskeletal Diseases in the United States: Prevalence, Societal and Economic Cost, American Academy of Orthopaedic Surgeons, 2008. http://books.google.co.uk/books?id=Mp0TAQAAMAAJ. [19] A. Wright, T.G. Mayer, R.J. Gatchel, Outcomes of disabling cervical spine disorders in compensation injuries - A prospective comparison to tertiary rehabilitation response for chronic lumbar spinal disorders, Spine (Phila Pa 1976). 24 (1999) 178–183. doi:Doi 10.1097/00007632-199901150-00020. [20] W.L. Eckalbar, R.E. Fisher, A. Rawls, K. Kusumi, Scoliosis and segmentation defects of the vertebrae, Wiley Interdiscip. Rev. Dev. Biol. 1 (2012) 401–423. doi:10.1002/wdev.34. [21] M. Nordin, V.H. Frankel, D. Leger, Basic biomechanics of the musculoskeletal system, 4th ed., Lippincott Williams & Wilkins, Baltimore, MD ; London, 2012. [22] O.A. Onan, M.H. Heggeness, J.A. Hipp, A motion analysis of the cervical facet joint, Spine (Phila Pa 1976). 23 (1998) 430–439. [23] C.R. Clark, T.B. Ducker, Cervical Spine Research Society. Editorial Committee., The cervical spine, 3rd ed., Lippincott-Raven, Philadelphia, 1998. [24] J.D. Bartleson, H.G. Deen, Spine disorders : medical and surgical management, Cambridge University Press, Cambridge, 2009. [25] V.K. Goel, A. Faizan, V. Palepu, S. Bhattacharya, Parameters that effect spine biomechanics following cervical disc replacement, Eur. Spine J. 21 Suppl 5 (2012) S688-99. doi:10.1007/s00586-011-1816-4. [26] G.V.K. Faizan A Krishna M, Friesem T, Effects of removal of uncinate process in the cervical disc replacement model: a finite element study, in: 53rd Annu. Meet. Orthop. Res. Soc., San Diego, CA, 2007. [27] J.T. Snyder, M.N. Tzermiadianos, A.J. Ghanayem, L.I. Voronov, A. Rinella, A. Dooris, G. Carandang, S.M. Renner, R.M. Havey, A.G. Patwardhan, Effect of uncovertebral joint excision on the motion response of the cervical spine after total disc replacement, Spine (Phila Pa 1976). 32 (2007) 2965–2969. doi:10.1097/BRS.0b013e31815cd482. [28] N. Bogduk, S. Mercer, Biomechanics of the cervical spine. I: Normal kinematics, Clin Biomech (Bristol, Avon). 15 (2000) 633–648. http://www.ncbi.nlm.nih.gov/pubmed/10946096. [29] M. Muller-Gerbl, S. Weisser, U. Linsenmeier, The distribution of mineral density in the cervical vertebral endplates, Eur. Spine J. 17 (2008) 432–438. doi:10.1007/s00586-008-0601-5. [30] E.C. Benzel, The cervical spine, 5th ed., Lippincott Williams & Wilkins, Philadelphia, PA, USA, 2012. [31] P.C. Ivancic, M.P. Coe, A.B. Ndu, Y. Tominaga, E.J. Carlson, W. Rubin, F.H. Dipl-Ing, M.M. Panjabi, Dynamic mechanical properties of intact human cervical spine ligaments, Spine J. 7 (2007) 659–665. doi:http://dx.doi.org/10.1016/j.spinee.2006.10.014. [32] H.C. Elliott, Cross-sectional diameters and areas of the human spinal cord, Anat Rec. 93 (1945) 287–293. http://www.ncbi.nlm.nih.gov/pubmed/21008200. [33] A.A. White, M.M. Panjabi, Clinical biomechanics of the spine, 2nd ed., Lippincott, Philadelphia, 1990. [34] L.T. Twomey, J.R. Taylor, Age-Changes in Lumbar Vertebrae and Intervertebral Disks, Clin. Orthop. Relat. Res. (1987) 97–104. [35] H.S. An, P.A. Anderson, V.M. Haughton, J.C. Iatridis, J.D. Kang, J.C. Lotz, R.N. Natarajan, T.R. Oegema Jr., P. Roughley, L.A. Setton, J.P. Urban, T. Videman, G.B. Andersson, J.N. Weinstein, Introduction: disc degeneration: summary, Spine (Phila Pa 1976). 29 (2004) 2677–2678. http://www.ncbi.nlm.nih.gov/pubmed/15564916. [36] J. Yu, P.C. Winlove, S. Roberts, J.P. Urban, Elastic fibre organization in the intervertebral discs of the bovine tail, J Anat. 201 (2002) 465–475. http://www.ncbi.nlm.nih.gov/pubmed/12489758. [37] J.P.G. Urban, A. Maroudas, M.T. Bayliss, J. Dillon, Swelling Pressures of Proteoglycans at the Concentrations Found in Cartilaginous Tissues, Biorheology. 16 (1979) 447–464. [38] F. Galbusera, M. van Rijsbergen, K. Ito, J.M. Huyghe, M. Brayda-Bruno, H.-J. Wilke, Ageing and degenerative changes of the intervertebral disc and their impact on spinal flexibility, Eur. Spine J. 23 (2014) 324–332. doi:10.1007/s00586-014-3203-4. [39] N.A. Ebraheim, A. Hassan, M. Lee, R. Xu, Functional anatomy of the lumbar spine, Semin. Pain Med. 2 (2004) 131–137. doi:http://dx.doi.org/10.1016/j.spmd.2004.08.004. [40] J. Schroder, M. Herbort, P. Rustemeyer, V. Vieth, H. Wassmann, Mechanical response of cervical vertebral endplates to axial loading, Zentralbl Neurochir. 67 (2006) 188–192. doi:10.1055/s-2006-942279. [41] T.G. Lowe, S. Hashim, L.A. Wilson, M.F. O’Brien, D.A. Smith, M.J. Diekmann, J. Trommeter, A biomechanical study of regional endplate strength and cage morphology as it relates to structural interbody support, Spine (Phila Pa 1976). 29 (2004) 2389–2394. [42] R.S. Ochia, A.F. Tencer, R.P. Ching, Effect of loading rate on endplate and vertebral body strength in human lumbar vertebrae, J Biomech. 36 (2003) 1875–1881. doi:http://dx.doi.org/10.1016/S0021-9290(03)00211-2. [43] S. Roberts, S.M. Eisenstein, J. Menage, E.H. Evans, I.K. Ashton, Mechanoreceptors in intervertebral discs - Morphology, distribution, and neuropeptides, Spine (Phila Pa 1976). 20 (1995) 2645–2651. doi:Doi 10.1097/00007632-199512150-00005. [44] S.P. Moroney, A.B. Schultz, J.A. Miller, Analysis and measurement of neck loads, J Orthop Res. 6 (1988) 713–720. doi:10.1002/jor.1100060514. [45] D.A. Winter, Anthropometry, in: Biomech. Mot. Control Hum. Mov., John Wiley & Sons, Inc., 2009: pp. 82–106. doi:10.1002/9780470549148.ch4. [46] M.M. Panjabi, J. Cholewicki, K. Nibu, J. Grauer, L.B. Babat, J. Dvorak, Critical load of the human cervical spine: an in vitro experimental study, Clin Biomech (Bristol, Avon). 13 (1998) 11–17. http://www.ncbi.nlm.nih.gov/pubmed/11415766. [47] J.A. Buckwalter, Aging and degeneration of the human intervertebral disc, Spine (Phila Pa 1976). 20 (1995) 1307–1314. http://www.ncbi.nlm.nih.gov/pubmed/7660243. [48] C. Lansade, S. Laporte, P. Thoreux, M.A. Rousseau, W. Skalli, F. Lavaste, Three-dimensional analysis of the cervical spine kinematics: effect of age and gender in healthy subjects, Spine (Phila Pa 1976). 34 (2009) 2900–2906. doi:10.1097/BRS.0b013e3181b4f667. [49] D.. H. Cobian B.; Daehn, N.; Anderson, P.A, Comparison of Daily Motion of the Cervical and Lumbar Spine to ASTM F2423-11 and ISO 18192-1.2011 Standard Testing, Static Dyn. Spinal Implant. Are We Eval. Them Appropriately? 1535 (2012) 14. doi:10.1520/JAI103522. [50] S.E. Bennett, R.J. Schenk, E.D. Simmons, Active range of motion utilized in the cervical spine to perform daily functional tasks, J Spinal Disord Tech. 15 (2002) 307–311. [51] E. Lysell, Motion in the cervical spine. An experimental study on autopsy specimens, Acta Orthop Scand. (1969) Suppl 123:1+. http://www.ncbi.nlm.nih.gov/pubmed/4907116. [52] M. Panjabi, J. Dvorak, J. Crisco 3rd, T. Oda, A. Hilibrand, D. Grob, Flexion, extension, and lateral bending of the upper cervical spine in response to alar ligament transections, J Spinal Disord. 4 (1991) 157–167. http://www.ncbi.nlm.nih.gov/pubmed/1806080. [53] M.P. Steinmetz, T.E. Mroz, E.C. Benzel, Craniovertebral junction: biomechanical considerations, Neurosurgery. 66 (2010) 7–12. doi:10.1227/01.NEU.0000366109.85796.42. [54] V.K. Goel, C.R. Clark, D. McGowan, S. Goyal, An in-vitro study of the kinematics of the normal, injured and stabilized cervical spine, J Biomech. 17 (1984) 363–376. http://www.ncbi.nlm.nih.gov/pubmed/6736071. [55] S.P. Cohen, Epidemiology, Diagnosis, and Treatment of Neck Pain, Mayo Clin. Proc. 90 (2015) 284–299. doi:10.1016/j.mayocp.2014.09.008. [56] K. Fujiwara, M. Fujimoto, H. Owaki, J. Kono, T. Nakase, K. Yonenobu, T. Ochi, Cervical lesions related to the systemic progression in rheumatoid arthritis, Spine (Phila Pa 1976). 23 (1998) 2052–2056. http://www.ncbi.nlm.nih.gov/pubmed/9794048. [57] W.O. Spitzer, M.L. Skovron, L.R. Salmi, J.D. Cassidy, J. Duranceau, S. Suissa, E. Zeiss, M.L. Skooron, L.R. Salmi, J.D. Cassidy, J. Duranceau, S. Suissa, E. Zeiss, Scientific Monograph of the Quebec Task-Force on Whiplash-Associated Disorders - Redefining Whiplash and Its Management, Spine (Phila Pa 1976). 20 (1995) 2372. [58] R. Ferrari, Prevention of chronic pain after whiplash, Emerg Med J. 19 (2002) 526–530. http://www.ncbi.nlm.nih.gov/pubmed/12421777. [59] H.H. Bohlman, S.E. Emery, D.B. Goodfellow, P.K. Jones, Robinson anterior cervical discectomy and arthrodesis for cervical radiculopathy. Long-term follow-up of one hundred and twenty-two patients, J Bone Jt. Surg Am. 75 (1993) 1298–1307. http://www.ncbi.nlm.nih.gov/pubmed/8408151. [60] T. Adamson, S.S. Godil, M. Mehrlich, S. Mendenhall, A.L. Asher, M.J. McGirt, Anterior cervical discectomy and fusion in the outpatient ambulatory surgery setting compared with the inpatient hospital setting: analysis of 1000 consecutive cases, J. Neurosurg. Spine. 24 (2016) 878–884. doi:10.3171/2015.8.SPINE14284. [61] P.S. Saphier, M.S. Arginteanu, F.M. Moore, A.A. Steinberger, M.B. Camins, Stress-shielding compared with load-sharing anterior cervical plate fixation: a clinical and radiographic prospective analysis of 50 patients, J Neurosurg Spine. 6 (2007) 391–397. doi:10.3171/spi.2007.6.5.391. [62] U.K. Chang, D.H. Kim, M.C. Lee, R. Willenberg, S.H. Kim, J. Lim, Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion, J Neurosurg Spine. 7 (2007) 33–39. doi:10.3171/SPI-07/07/033. [63] M.P. Kelly, J.M. Mok, R.F. Frisch, B.K. Tay, Adjacent segment motion after anterior cervical discectomy and fusion versus Prodisc-c cervical total disk arthroplasty: analysis from a randomized, controlled trial, Spine (Phila Pa 1976). 36 (2011) 1171–1179. doi:10.1097/BRS.0b013e3181ec5c7d. [64] J. Goffin, E. Geusens, N. Vantomme, E. Quintens, Y. Waerzeggers, B. Depreitere, F. Van Calenbergh, J. van Loon, Long-term follow-up after interbody fusion of the cervical spine, J Spinal Disord Tech. 17 (2004) 79–85. http://www.ncbi.nlm.nih.gov/pubmed/15260088. [65] A.S. Hilibrand, G.D. Carlson, M.A. Palumbo, P.K. Jones, H.H. Bohlman, Radiculopathy and myelopathy at segments adjacent to the site of a previous anterior cervical arthrodesis, J. Bone Jt. Surgery-American Vol. 81A (1999) 519–528. [66] D.-H. Lee, J.H. Cho, C.J. Hwang, C.S. Lee, S.K. Cho, C. Kim, J.-K. Ha, What is the Fate of Pseudarthrosis Detected 1 Year After Anterior Cervical Discectomy and Fusion?, Spine (Phila. Pa. 1976). (2017) 1. doi:10.1097/BRS.0000000000002077. [67] B. Moatz, P.J. Tortolani, Cervical disc arthroplasty: Pros and cons, Surg Neurol Int. 3 (2012) S216-24. doi:10.4103/2152-7806.98582. [68] M. Thaler, S. Hartmann, M. Gstottner, R. Lechner, M. Gabl, C. Bach, Footprint mismatch in total cervical disc arthroplasty, Eur. Spine J. 22 (2013) 759–765. doi:10.1007/s00586-012-2594-3. [69] M. Gstoettner, D. Heider, M. Liebensteiner, C.M. Bach, Footprint mismatch in lumbar total disc arthroplasty, Eur. Spine J. 17 (2008) 1470–1475. doi:10.1007/s00586-008-0780-0. [70] B.M. Wroblewski, P.D. Siney, P.A. Fleming, The principle of low frictional torque in the Charnley total hip replacement, J Bone Jt. Surg Br. 91 (2009) 855–858. doi:10.1302/0301-620X.91B7.22027. [71] A. Shaheen, D.E. Shepherd, Lubrication regimes in lumbar total disc arthroplasty, Proc Inst Mech Eng H. 221 (2007) 621–627. http://www.ncbi.nlm.nih.gov/pubmed/17937201. [72] H. Yao, W.Y. Gu, Physical signals and solute transport in human intervertebral disc during compressive stress relaxation: 3D finite element analysis, Biorheology. 43 (2006) 323–335. http://www.ncbi.nlm.nih.gov/pubmed/16912405. [73] W. V Dowson. D, Bio-tribology, in: D. T.C (Ed.), Rheol. Lubr., Science Publishers, Barking, 1973: pp. 81–88. [74] E. Ingham, J. Fisher, Biological reactions to wear debris in total joint replacement, Proc Inst Mech Eng H. 214 (2000) 21–37. http://www.ncbi.nlm.nih.gov/pubmed/10718048. [75] D.J. Langton, T.J. Joyce, S.S. Jameson, J. Lord, M. Van Orsouw, J.P. Holland, A. V Nargol, K.A. De Smet, Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear, J Bone Jt. Surg Br. 93 (2011) 164–171. doi:10.1302/0301-620X.93B2.25099. [76] Dowson. D, Biotribology of natural and replacement joints, in: V.C. Mow (Ed.), Biomech. Diarthrodial Joints, Springer Verlag, New York, 1990: pp. 303–345. [77] A. Bennett, Higginso.Gr, Hydrodynamic Lubrication of Soft Solids, J. Mech. Eng. Sci. 12 (1970) 218-. [78] J.S. Hou, V.C. Mow, W.M. Lai, M.H. Holmes, An analysis of the squeeze-film lubrication mechanism for articular cartilage, J Biomech. 25 (1992) 247–259. http://www.ncbi.nlm.nih.gov/pubmed/1564060. [79] M. Jagatia, D. Jalali-Vahid, Z.M. Jin, Elastohydrodynamic lubrication analysis of ultra-high molecular weight polyethylene hip joint replacements under squeeze-film motion, Proc Inst Mech Eng H. 215 (2001) 141–152. [80] P.S. Walker, D. Dowson, M.D. Longfield, V. Wright, “Boosted lubrication” in synovial joints by fluid entrapment and enrichment, Ann Rheum Dis. 27 (1968) 512–520. http://www.ncbi.nlm.nih.gov/pubmed/5728097. [81] P.R. Lewis, C.W. McCutchen, Experimental evidence for weeping lubrication in mammalian joints, Nature. 184 (1959) 1285. [82] J.F. Archard, Contact and Rubbing of Flat Surfaces, J. Appl. Phys. 24 (1953) 981–988. doi:10.1063/1.1721448. [83] R.G. Bayer, Mechanical Wear Fundamentals and Testing, Revised and Expanded, Taylor & Francis, 2004. http://books.google.co.uk/books?id=Q64Kq2HlyucC. [84] H.C. Amstutz, P. Campbell, N. Kossovsky, I.C. Clarke, Mechanism and clinical significance of wear debris-induced osteolysis, Clin Orthop Relat Res. (1992) 7–18. http://www.ncbi.nlm.nih.gov/pubmed/1537177. [85] S.B. Goodman, T. Wright, 2007 AAOS/NIH osteolysis and implant wear: biological, biomedical engineering, and surgical principles. Introduction, J Am Acad Orthop Surg. 16 Suppl 1 (2008) x–xi. doi:16/suppl_1/x [pii]. [86] S.M. Kurtz, A. van Ooij, R. Ross, J. de Waal Malefijt, J. Peloza, L. Ciccarelli, M.L. Villarraga, Polyethylene wear and rim fracture in total disc arthroplasty, Spine J. 7 (2007) 12–21. doi:http://dx.doi.org/10.1016/j.spinee.2006.05.012. [87] Y. Yan, A. Neville, D. Dowson, Biotribocorrosion—an appraisal of the time dependence of wear and corrosion interactions: II. Surface analysis, J. Phys. D. Appl. Phys. 39 (2006) 3206. http://stacks.iop.org/0022-3727/39/i=15/a=S11. [88] Y. Yan, A. Neville, D. Dowson, Biotribocorrosion - an appraisal of the time dependence of wear and corrosion interactions: I. The role of corrosion, J. Phys. D. Appl. Phys. 39 (2006) 3200–3205. doi:10.1088/0022-3727/39/15/S10. [89] S.M. Kurtz, The UHMWPE Handbook: Ultra-High Molecular Weight Polyethylene in Total Joint Replacement, Elsevier Science, 2004. http://books.google.co.uk/books?id=bkuFjppEdMcC. [90] R. Narayan, Biomedical Materials, Springer Science & Business Media, New York, 2009. http://books.google.co.uk/books?id=wyFYTCus8OgC. [91] Substech.com, Abrasive wear, (2012). http://www.substech.com/dokuwiki/doku.php?id=mechanisms_of_wear. [92] B.H. Cummins, J.T. Robertson, S.S. Gill, Surgical experience with an implanted artificial cervical joint, J Neurosurg. 88 (1998) 943–948. doi:10.3171/jns.1998.88.6.0943. [93] N. Hallab, H.D. Link, P.C. McAfee, Biomaterial optimization in total disc arthroplasty, Spine (Phila Pa 1976). 28 (2003) S139-52. doi:10.1097/01.BRS.0000092214.87225.80. [94] I. GOTMAN, Characteristics of Metals Used in Implants, J. Endourol. 11 (1997) 383–389. doi:10.1089/end.1997.11.383. [95] P.F. Doorn, J.M. Mirra, P.A. Campbell, H.C. Amstutz, Tissue reaction to metal on metal total hip prostheses, Clin Orthop Relat Res. (1996) S187-205. http://www.ncbi.nlm.nih.gov/pubmed/8769334. [96] D. Bitar, J. Parvizi, Biological response to prosthetic debris., World J. Orthop. 6 (2015) 172–89. doi:10.5312/wjo.v6.i2.172. [97] J.P. Lemaire, H. Carrier, H. Sariali el, W. Skalli, F. Lavaste, Clinical and radiological outcomes with the Charite artificial disc: a 10-year minimum follow-up, J Spinal Disord Tech. 18 (2005) 353–359. http://www.ncbi.nlm.nih.gov/pubmed/16021017. [98] R.C. Huang, F.P. Girardi, F.P. Cammisa Jr., T.M. Wright, The implications of constraint in lumbar total disc replacement, J Spinal Disord Tech. 16 (2003) 412–417. http://www.ncbi.nlm.nih.gov/pubmed/12902958. [99] P. V Mummaneni, J.K. Burkus, R.W. Haid, V.C. Traynelis, T.A. Zdeblick, Clinical and radiographic analysis of cervical disc arthroplasty compared with allograft fusion: a randomized controlled clinical trial, J Neurosurg Spine. 6 (2007) 198–209. doi:10.3171/spi.2007.6.3.198. [100] J.K. Burkus, R.W. Haid, V.C. Traynelis, P. V Mummaneni, Long-term clinical and radiographic outcomes of cervical disc replacement with the Prestige disc: results from a prospective randomized controlled clinical trial, J Neurosurg Spine. 13 (2010) 308–318. doi:10.3171/2010.3.SPINE09513. [101] J.K. Burkus, V.C. Traynelis, R.W. Haid, P. V. Mummaneni, Clinical and radiographic analysis of an artificial cervical disc: 7-year follow-up from the Prestige prospective randomized controlled clinical trial, J. Neurosurg. Spine. 21 (2014) 516–528. doi:10.3171/2014.6.SPINE13996. [102] F. Porchet, N.H. Metcalf, Clinical outcomes with the Prestige II cervical disc: preliminary results from a prospective randomized clinical trial, Neurosurg Focus. 17 (2004) E6. http://www.ncbi.nlm.nih.gov/pubmed/15636562. [103] D. Murrey, M. Janssen, R. Delamarter, J. Goldstein, J. Zigler, B. Tay, B. Darden, Results of the prospective, randomized, controlled multicenter Food and Drug Administration investigational device exemption study of the ProDisc-C total disc replacement versus anterior discectomy and fusion for the treatment of 1-level symptomatic cervi, Spine J. 9 (2009) 275–286. doi:10.1016/j.spinee.2008.05.006. [104] R.B. Delamarter, D. Murrey, M.E. Janssen, J.A. Goldstein, J. Zigler, B.K.B. Tay, B. Darden Ii, Results at 24 months from the prospective, randomized, multicenter Investigational Device Exemption trial of ProDisc-C versus anterior cervical discectomy and fusion with 4-year follow-up and continued access patients, SAS J. 4 (2010) 122–128. doi:http://dx.doi.org/10.1016/j.esas.2010.09.001. [105] J.E. Zigler, R. Delamarter, D. Murrey, J. Spivak, M. Janssen, ProDisc-C and Anterior Cervical Discectomy and Fusion as Surgical Treatment for Single-Level Cervical Symptomatic Degenerative Disc Disease Five-Year Results of a Food and Drug Administration Study, Spine (Phila Pa 1976). 38 (2013) 203–209. doi:Doi 10.1097/Brs.0b013e318278eb38. [106] R.C. Sasso, P.A. Anderson, K.D. Riew, J.G. Heller, Results of cervical arthroplasty compared with anterior discectomy and fusion: four-year clinical outcomes in a prospective, randomized controlled trial, Orthopedics. 34 (2011) 889. doi:10.3928/01477447-20110922-24. [107] R.C. Sasso, J.D. Smucker, R.J. Hacker, J.G. Heller, Clinical outcomes of BRYAN cervical disc arthroplasty: a prospective, randomized, controlled, multicenter trial with 24-month follow-up, J Spinal Disord Tech. 20 (2007) 481–491. doi:10.1097/BSD.0b013e3180310534. [108] J. Marzluff, J. McConnell, C. Tomaras, W. Peppelman, I. Volcan, K. Baker, 2-Year Multicenter Follow-up in a Prospective Randomized Clinical Trial: Comparison of a Cervical Artificial Disc to an ACDF Treatment, Spine J. 10 (2010) S135–S136. doi:http://dx.doi.org/10.1016/j.spinee.2010.07.349. [109] A. Vaccaro, W. Beutler, W. Peppelman, J.M. Marzluff, J. Highsmith, A. Mugglin, G. DeMuth, M. Gudipally, K.J. Baker, Clinical Outcomes With Selectively Constrained SECURE-C Cervical Disc Arthroplasty, Spine (Phila. Pa. 1976). 38 (2013) 2227–2239. doi:10.1097/BRS.0000000000000031. [110] F.M. Phillips, J.Y.B. Lee, F.H. Geisler, A. Cappuccino, C.D. Chaput, J.G. DeVine, C. Reah, K.M. Gilder, K.M. Howell, P.C. McAfee, A Prospective, Randomized, Controlled Clinical Investigation Comparing PCM Cervical Disc Arthroplasty With Anterior Cervical Discectomy and Fusion, Spine (Phila. Pa. 1976). 38 (2013) E907–E918. doi:10.1097/BRS.0b013e318296232f. [111] F.M. Phillips, F.H. Geisler, K.M. Gilder, C. Reah, K.M. Howell, P.C. McAfee, Long-term Outcomes of the US FDA IDE Prospective, Randomized Controlled Clinical Trial Comparing PCM Cervical Disc Arthroplasty With Anterior Cervical Discectomy and Fusion, Spine (Phila. Pa. 1976). 40 (2015) 674–683. doi:10.1097/BRS.0000000000000869. [112] M. Hisey, H. Bae, R. Davis, S. Gaede, G. Hoffman, K. Kim, P. Nunley, D. Peterson, R. Rashbaum, J. Stokes, Multi-center, Prospective, Randomized, Controlled Investigational Device Exemption Clinical Trial Comparing Mobi?C Cervical Artificial Disc to Anterior Discectomy and Fusion in the Treatment of Symptomatic Degenerative Disc Disease in the Cervical Spine, Int. J. Spine Surg. 8 (2014) 7–7. doi:10.14444/1007. [113] M.S. Hisey, H.W. Bae, R.J. Davis, S. Gaede, G. Hoffman, K.D. Kim, P.D. Nunley, D. Peterson, R.F. Rashbaum, J. Stokes, D.D. Ohnmeiss, Prospective, Randomized Comparison of Cervical Total Disk Replacement Versus Anterior Cervical Fusion, J. Spinal Disord. Tech. 28 (2015) E237–E243. doi:10.1097/BSD.0000000000000185. [114] M.S. Hisey, J.E. Zigler, R. Jackson, P.D. Nunley, H.W. Bae, K.D. Kim, D.D. Ohnmeiss, Prospective, Randomized Comparison of One-level Mobi-C Cervical Total Disc Replacement vs. Anterior Cervical Discectomy and Fusion: Results at 5-year Follow-up., Int. J. Spine Surg. 10 (2016) 10. doi:10.14444/3010. [115] M.F. Gornet, J.K. Burkus, M.E. Shaffrey, P.J. Argires, H. Nian, F.E. Harrell, Cervical disc arthroplasty with PRESTIGE LP disc versus anterior cervical discectomy and fusion: a prospective, multicenter investigational device exemption study, J. Neurosurg. Spine. 23 (2015) 558–573. doi:10.3171/2015.1.SPINE14589. [116] M. Gornet, J.K. Burkus, M. Shaffrey, H. Nian, F. Harrell, Cervical Disc Arthroplasty with Prestige LP Disc Versus Anterior Cervical Discectomy and Fusion: Seven-Year Outcomes, Int. J. Spine Surg. 10 (2016) 24. doi:10.14444/3024. [117] J.G. Heller, R.C. Sasso, S.M. Papadopoulos, P.A. Anderson, R.G. Fessler, R.J. Hacker, D. Coric, J.C. Cauthen, D.K. Riew, Comparison of BRYAN Cervical Disc Arthroplasty With Anterior Cervical Decompression and Fusion, Spine (Phila. Pa. 1976). 34 (2009) 101–107. doi:10.1097/BRS.0b013e31818ee263. [118] J. Fisher, J. Bell, P.S. Barbour, J.L. Tipper, J.B. Matthews, A.A. Besong, M.H. Stone, E. Ingham, A novel method for the prediction of functional biological activity of polyethylene wear debris, Proc Inst Mech Eng H. 215 (2001) 127–132. http://www.ncbi.nlm.nih.gov/pubmed/11382071. [119] S.M. Kurtz, J.M. Toth, R. Siskey, L. Ciccarelli, D. MacDonald, J. Isaza, T. Lanman, I. Punt, M. Steinbeck, J. Goffin, A. van Ooij, The Latest Lessons Learned from Retrieval Analyses of Ultra-High Molecular Weight Polyethylene, Metal-on-Metal, and Alternative Bearing Total Disc Replacements, Semin. Spine Surg. 24 (2012) 57–70. doi:http://dx.doi.org/10.1053/j.semss.2011.11.011. [120] M.A. Wimmer, A. Fischer, R. Buscher, R. Pourzal, C. Sprecher, R. Hauert, J.J. Jacobs, Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers, J Orthop Res. 28 (2010) 436–443. doi:10.1002/jor.21020. [121] P.A. Anderson, J.P. Rouleau, J.M. Toth, K.D. Riew, A comparison of simulator-tested and -retrieved cervical disc prostheses. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004, J Neurosurg Spine. 1 (2004) 202–210. doi:10.3171/spi.2004.1.2.0202. [122] D. Lebl, F. Cammisa, F. Girardi, T. Wright, C. Abjornson, Analysis of Wear, Surface Properties, and Fixation of Explanted Cervical Total Disc Replacements, Spine J. 11 (2011) S45. doi:http://dx.doi.org/10.1016/j.spinee.2011.08.119. [123] D.R. Lebl, F.P. Cammisa Jr., F.P. Girardi, T. Wright, C. Abjornson, The mechanical performance of cervical total disc replacements in vivo: prospective retrieval analysis of prodisc-C devices, Spine (Phila Pa 1976). 37 (2012) 2151–2160. doi:10.1097/BRS.0b013e31826b3f61. [124] L.M. Tumialan, W.M. Gluf, Progressive vertebral body osteolysis after cervical disc arthroplasty, Spine (Phila Pa 1976). 36 (2011) E973-8. doi:10.1097/BRS.0b013e3181fd863b. [125] C.J. Devin, T.G. Myers, J.D. Kang, Chronic failure of a lumbar total disc replacement with osteolysis. Report of a case with nineteen-year follow-up, J Bone Jt. Surg Am. 90 (2008) 2230–2234. doi:10.2106/JBJS.G.01712. [126] A. van Ooij, S.M. Kurtz, F. Stessels, H. Noten, L. van Rhijn, Polyethylene wear debris and long-term clinical failure of the Charite disc prosthesis: a study of 4 patients, Spine (Phila Pa 1976). 32 (2007) 223–229. doi:10.1097/01.brs.0000251370.56327.c6. [127] B.W. Cunningham, C.M. Orbegoso, A.E. Dmitriev, N.J. Hallab, J.C. Sefter, P. Asdourian, P.C. McAfee, The effect of spinal instrumentation particulate wear debris. an in vivo rabbit model and applied clinical study of retrieved instrumentation cases, Spine J. 3 (2003) 19–32. http://www.ncbi.nlm.nih.gov/pubmed/14589241. [128] R.D. Guyer, J. Shellock, B. MacLennan, D. Hanscom, R.Q. Knight, P. McCombe, J.J. Jacobs, R.M. Urban, D. Bradford, D.D. Ohnmeiss, Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases, Spine (Phila Pa 1976). 36 (2011) E492-7. doi:10.1097/BRS.0b013e31820ea9a2. [129] D.A. Cavanaugh, P.D. Nunley, E.J. Kerr 3rd, D.J. Werner, A. Jawahar, Delayed hyper-reactivity to metal ions after cervical disc arthroplasty: a case report and literature review, Spine (Phila Pa 1976). 34 (2009) E262-5. doi:10.1097/BRS.0b013e318195dd60. [130] M. Lagier, M. Briere, H. Giorgi, S. Fuentes, B. Blondel, P. Tropiano, Delayed hypersensitivity reaction after cervical disc replacement: A case report, Orthop. Traumatol. Surg. Res. 101 (2015) 643–645. doi:10.1016/j.otsr.2015.05.005. [131] M.R. Berry, B.G. Peterson, D.H. Alander, A granulomatous mass surrounding a Maverick total disc replacement causing iliac vein occlusion and spinal stenosis: a case report, J Bone Jt. Surg Am. 92 (2010) 1242–1245. doi:10.2106/JBJS.H.01625. [132] J. Francois, R. Coessens, P. Lauweryns, Early removal of a Maverick disc prosthesis: surgical findings and morphological changes, Acta Orthop Belg. 73 (2007) 122–127. http://www.ncbi.nlm.nih.gov/pubmed/17441671. [133] T.R. Green, J. Fisher, M. Stone, B.M. Wroblewski, E. Ingham, Polyethylene particles of a “critical size” are necessary for the induction of cytokines by macrophages in vitro, Biomaterials. 19 (1998) 2297–2302. http://www.ncbi.nlm.nih.gov/pubmed/9884043. [134] C. Brown, J. Fisher, E. Ingham, Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses, Proc Inst Mech Eng H. 220 (2006) 355–369. http://www.ncbi.nlm.nih.gov/pubmed/16669401. [135] International Organization for Standardization, BS ISO-18192-1:2011 - Implants for surgery - Wear of total intervertebral spinal disc prostheses - Part 1: Loading and displacement parameters for wear testing and corresponding environmental conditions for test, (2011). [136] ASTM, ASTM Standard F2423-11, Stand. Guid. Funct. Kinematic, Wear Assess. Total Disc Prostheses. (2011). doi:10.1520/F2423-11. [137] P.E. Pare, F.W. Chan, S. Bhattacharya, V.K. Goel, Surface slide track mapping of implants for total disc arthroplasty, J Biomech. 42 (2009) 131–139. doi:10.1016/j.jbiomech.2008.10.025. [138] S.M. Kurtz, L. Ciccarelli, M.L. Harper, R. Siskey, J. Shorez, F.W. Chan, Comparison of in vivo and simulator-retrieved metal-on-metal cervical disc replacements, Int. J. Spine Surg. 6 (2012) 145–156. doi:http://dx.doi.org/10.1016/j.ijsp.2012.03.002. [139] S.M.C.F.W. Kurtz Pare P.E, et al., Correlation of in vivo- and simulator-retrieved metal-on-metal cervical disc replacements, 7th Annu. Meet. Spine Arthroplast. Soc. (2007). [140] R.L.. K. Siskey S.M.; Shah, P.; Ciccarelli, L.; Harper, M.; Chan, F.; White, S., Validation of ISO-Standard Wear Testing with Retrieved Metal-on-Metal Cervical Disc Replacements, 54th Annu. Meet. Orthop. Res. Soc. (2008). [141] C.J. Kelly N Wright T, Retrieval analysis of ProDisc total disc replacements, 54th Annu. Meet. Orthop. Res. Soc. (2008). [142] W. Nechtow, M. Bushelow, M. Hintner, A. Ochs, C. Kaddick, Cervical Disc Prosthesis Polyethylene Wear Following The ISO Cervical Test Poster No . 1926 • 54th Annual Meeting of the Orthopaedic Research Society, 1 (2002) 18192. http://www.ors.org/Transactions/54/1926.pdf (accessed April 8, 2017). [143] M. Bushelow, W. Nechtow, M. Hinter, H. Dressel, C. Kaddick, M.E. Gmbh, W. Chester, Wear Testing of a Cervical Total Disc Replacement : Effect of Motion and Load Parameters on Wear Rate and Particle Morphology 1 EndoLab Materials and Methods : All testing was performed at EndoLab Mechanical Engineering GmbH ( Rosenheim , GR ). Testing wa, 29 (2006) 2006. http://www.ors.org/Transactions/54/1925.pdf (accessed April 8, 2017). [144] P.J. Hyde, J. Tipper, J. Fisher, R.M. Hall, Wear and biological effects of a semi-constrained total disc replacement subject to modified ISO standard test conditions, J. Mech. Behav. Biomed. Mater. 44 (2015) 43–52. doi:10.1016/j.jmbbm.2014.12.001. [145] J.L. Tipper, A.L. Galvin, S. Williams, H.M. McEwen, M.H. Stone, E. Ingham, J. Fisher, Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators, J Biomed Mater Res A. 78 (2006) 473–480. doi:10.1002/jbm.a.30824. [146] T.R. Green, J. Fisher, J.B. Matthews, M.H. Stone, E. Ingham, Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles, J Biomed Mater Res. 53 (2000) 490–497. [147] K.M. Holmberg A.`, Coatings Tribology: Properties, Mechanisms, Techniques and Applications in Surface Engineering, 2nd ed., Elsevier, Oxford, 2009. [148] A. Matthews, Advanced surface coatings: a handbook of surface engineering, Blackie, Glasgow, UK, 1991. [149] C. Christou, Z.H. Barber, Ionization of sputtered material in a planar magnetron discharge, J. Vac. Sci. Technol. A Vacuum, Surfaces Film. 18 (2000) 2897–2907. http://www.scopus.com/inward/record.url?eid=2-s2.0-0034318373&partnerID=40&md5=9bf0568125a1666aa8d200f616960e64. [150] T. Shimizu, H. Komiya, T. Watanabe, Y. Teranishi, H. Nagasaka, K. Morikawa, M. Yang, HIPIMS deposition of TiAlN films on inner wall of micro-dies and its applicability in micro-sheet metal forming, Surf. Coatings Technol. 250 (2014) 44–51. doi:http://dx.doi.org/10.1016/j.surfcoat.2014.02.008. [151] V. Kouznetsov, K. MacÁk, J.M. Schneider, U. Helmersson, I. Petrov, A novel pulsed magnetron sputter technique utilizing very high target power densities, Surf. Coatings Technol. 122 (1999) 290–293. http://www.scopus.com/inward/record.url?eid=2-s2.0-0000975178&partnerID=40&md5=997858bd1298305f27622ef858a5185d. [152] K. Sarakinos, J. Alami, S. Konstantinidis, High power pulsed magnetron sputtering: A review on scientific and engineering state of the art, Surf. Coatings Technol. 204 (2010) 1661–1684. doi:http://dx.doi.org/10.1016/j.surfcoat.2009.11.013. [153] D.J. Berry, W.S. Harmsen, M.E. Cabanela, B.F. Morrey, Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components, J Bone Jt. Surg Am. 84–A (2002) 171–177. http://www.ncbi.nlm.nih.gov/pubmed/11861721. [154] P.F. Sharkey, W.J. Hozack, R.H. Rothman, S. Shastri, S.M. Jacoby, Insall Award paper. Why are total knee arthroplasties failing today?, Clin Orthop Relat Res. (2002) 7–13. http://www.ncbi.nlm.nih.gov/pubmed/12439231. [155] S.R.P. Silva, G.A.J. Amaratunga, Doping of rf plasma deposited diamond-like carbon films, Thin Solid Films. 270 (1995) 194–199. http://www.scopus.com/inward/record.url?eid=2-s2.0-0029516498&partnerID=40&md5=0003e753fa6bf960803a73cd8b64c7be. [156] A.A. Evtukh, V.G. Litovchenko, Y.M. Litvin, D. V Fedin, O.S. Dzyan, Y.N. Pedchenko, A.G. Chakhovskoi, T.E. Felter, Silicon doped diamond-like carbon films as a coating for improvement of electron field emission, J. Vac. Sci. Technol. B Microelectron. Nanom. Struct. 21 (2003) 627–630. http://www.scopus.com/inward/record.url?eid=2-s2.0-0037207783&partnerID=40&md5=86bc0f67a96f8795a579b1f4c2576398. [157] T. Wehlus, G. Thorwarth, F. Schwarz, M.F. Schneider, B. Saldamli, B. Stritzker, Biocompatible DLC coatings by PBII: Effects of doping and surface roughness, Phys. Status Solidi Curr. Top. Solid State Phys. 5 (2008) 952–955. http://www.scopus.com/inward/record.url?eid=2-s2.0-77951161128&partnerID=40&md5=4665a22f1d9f2fba0aed0eda204cdd86. [158] R. Hauert, A review of modified DLC coatings for biological applications, Diam. Relat. Mater. 12 (2003) 583–589. http://www.scopus.com/inward/record.url?eid=2-s2.0-0037852937&partnerID=40&md5=92c76a7aa72c017d3e2596873471df95. [159] C. Donnet, Recent progress on the tribology of doped diamond-like and carbon alloy coatings: A review, Surf. Coatings Technol. 100–101 (1998) 180–186. http://www.scopus.com/inward/record.url?eid=2-s2.0-0032026026&partnerID=40&md5=bef4c288e95a27ceb810057aa3792425. [160] L.A. Thomson, F.C. Law, N. Rushton, J. Franks, Biocompatibility of diamond-like carbon coating, Biomaterials. 12 (1991) 37–40. http://www.ncbi.nlm.nih.gov/pubmed/2009344. [161] F.Z. Cui, D.J. Li, A review of investigations on biocompatibility of diamond-like carbon and carbon nitride films, Surf. Coatings Technol. 131 (2000) 481–487. http://www.scopus.com/inward/record.url?eid=2-s2.0-0034532526&partnerID=40&md5=aec0c81c6581d564f930f76ed5f3a155. [162] R.K. Roy, K.R. Lee, Biomedical applications of diamond-like carbon coatings: A review, J. Biomed. Mater. Res. - Part B Appl. Biomater. 83 (2007) 72–84. http://www.scopus.com/inward/record.url?eid=2-s2.0-34648824850&partnerID=40&md5=11bbc5e097fd398dc80cc682ab6f2f01. [163] C.A. Love, R.B. Cook, T.J. Harvey, P.A. Dearnley, R.J.K. Wood, Diamond like carbon coatings for potential application in biological implants—a review, Tribol. Int. 63 (2013) 141–150. doi:http://dx.doi.org/10.1016/j.triboint.2012.09.006. [164] R. Lappalainen, M. Selenius, A. Anttila, Y.T. Konttinen, S.S. Santavirta, Reduction of wear in total hip replacement prostheses by amorphous diamond coatings, J Biomed Mater Res B Appl Biomater. 66 (2003) 410–413. doi:10.1002/jbm.b.10026. [165] S. Affatato, M. Frigo, A. Toni, An in vitro investigation of diamond-like carbon as a femoral head coating, J Biomed Mater Res. 53 (2000) 221–226. [166] J.I. Oñate, M. Comin, I. Braceras, A. Garcia, J.L. Viviente, M. Brizuela, N. Garagorri, J.L. Peris, J.I. Alava, Wear reduction effect on ultra-high-molecular-weight polyethylene by application of hard coatings and ion implantation on cobalt chromium alloy, as measured in a knee wear simulation machine, Surf. Coatings Technol. 142–144 (2001) 1056–1062. doi:http://dx.doi.org/10.1016/S0257-8972(01)01074-X. [167] R. Lappalainen, S.S. Santavirta, Potential of coatings in total hip replacement, Clin. Orthop. Relat. Res. (2005) 72–79. http://www.scopus.com/inward/record.url?eid=2-s2.0-11844275898&partnerID=40&md5=96578c9c52e14919bccd0b8f5727cf56. [168] G Maestretti, D Noriega, P Otten, P.V. R Srour, BAGUERA® C – A New Cervical Disc Replacement Device, 2008. [169] M. Benmekhbi, J. Mortada, G. Lungu, D. Eichler, R. Srour, J.M. Vital, Baguera cervical disc prosthesis, Interact. Surg. 3 (2008) 201–204. doi:10.1007/s11610-008-0086-2. [170] G. Taeger, L.E. Podleska, B. Schmidt, M. Ziegler, D. Nast-Kolb, Comparison of Diamond-Like-Carbon and Alumina-Oxide articulating with Polyethylene in Total Hip Arthroplasty, Materwiss. Werksttech. 34 (2003) 1094–1100. http://www.scopus.com/inward/record.url?eid=2-s2.0-1642488161&partnerID=40&md5=8aa28ada83ec31c9aff7cccdf8a5c7b5. [171] T.J. Joyce, Examination of failed ex vivo metal-on-metal metatarsophalangeal prosthesis and comparison with theoretically determined lubrication regimes, Wear. 263 (2007) 1050–1054. http://www.scopus.com/inward/record.url?eid=2-s2.0-34548061162&partnerID=40&md5=94df9ad38bd20e554d7c21cd39b3ffb0. [172] R. Hauert, C. V Falub, G. Thorwarth, K. Thorwarth, C. Affolter, M. Stiefel, L.E. Podleska, G. Taeger, Retrospective lifetime estimation of failed and explanted diamond-like carbon coated hip joint balls, Acta Biomater. 8 (2012) 3170–3176. doi:10.1016/j.actbio.2012.04.016. [173] R. Hauert, G. Thorwarth, U. Müller, M. Stiefel, C. V Falub, K. Thorwarth, T.J. Joyce, Analysis of the in-vivo failure of the adhesive interlayer for a DLC coated articulating metatarsophalangeal joint, Diam. Relat. Mater. 25 (2012) 34–39. doi:http://dx.doi.org/10.1016/j.diamond.2012.02.001. [174] M.J. Pappas, G. Makris, F.F. Buechel, Titanium nitride ceramic film against polyethylene. A 48 million cycle wear test, Clin Orthop Relat Res. (1995) 64–70. [175] M.T. Raimondi, R. Pietrabissa, The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating, Biomaterials. 21 (2000) 907–913. [176] M.K. Harman, S.A. Banks, W.A. Hodge, Wear analysis of a retrieved hip implant with titanium nitride coating, J Arthroplast. 12 (1997) 938–945. [177] S.N. Massoud, J.B. Hunter, B.J. Holdsworth, W.A. Wallace, R. Juliusson, EARLY FEMORAL LOOSENING IN ONE DESIGN OF CEMENTED HIP REPLACEMENT, Bone Joint J. 79–B (1997). http://bjj.boneandjoint.org.uk/content/79-B/4/603.short (accessed August 26, 2017). [178] G.G. Fuentes, R. Rodriguez, J.C. Avelar-Batista, J. Housden, F. Montalá, L.J. Carreras, A.B. Cristóbal, J.J. Damborenea, T.J. Tate, Recent advances in the chromium nitride PVD process for forming and machining surface protection, J. Mater. Process. Technol. 167 (2005) 415–421. doi:10.1016/j.jmatprotec.2005.06.011. [179] J. Fisher, X.Q. Hu, J.L. Tipper, T.D. Stewart, S. Williams, M.H. Stone, C. Davies, P. Hatto, J. Bolton, M. Riley, C. Hardaker, G.H. Isaac, G. Berry, E. Ingham, An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads, Proc Inst Mech Eng H. 216 (2002) 219–230. [180] S. Williams, G. Isaac, P. Hatto, M.H. Stone, E. Ingham, J. Fisher, Comparative wear under different conditions of surface-engineered metal-on-metal bearings for total hip arthroplasty, J. Arthroplasty. 19 (2004) 112–117. doi:10.1016/j.arth.2004.09.014. [181] W. Österle, D. Klaffke, M. Griepentrog, U. Gross, I. Kranz, C. Knabe, Potential of wear resistant coatings on Ti–6Al–4V for artificial hip joint bearing surfaces, Wear. 264 (2008) 505–517. doi:http://dx.doi.org/10.1016/j.wear.2007.04.001. [182] R. Thorkildsen, O. Reigstad, M. R?kkum, Chrome nitride coating reduces wear of small, spherical CrCoMo metal-on-metal articulations in a joint simulator, J. Hand Surg. (European Vol. 42 (2017) 310–315. doi:10.1177/1753193416674161. [183] I. Leslie, S. Williams, G. Isaac, P. Hatto, E. Ingham, J. Fisher, Wear of surface-engineered metal-on-metal bearings for hip prostheses under adverse conditions with the head loading on the rim of the cup, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 227 (2013) 345–349. doi:10.1177/0954411912468542. [184] I.J. Leslie, Surface Engineering of Metal-on-Metal Hip Surface Replacements, University of Leeds, 2008. [185] D. de Villiers, A. Traynor, S.N. Collins, S. Banfield, J. Housden, J.C. Shelton, Chromium nitride coating for large diameter metal-on-polyethylene hip bearings under extreme adverse hip simulator conditions, Wear. 328 (2015) 363–368. doi:10.1016/j.wear.2015.02.060. [186] M. Mazzocchi, D. Gardini, P.L. Traverso, M.G. Faga, A. Bellosi, On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part II: chemical stability and wear resistance in body environment, J Mater Sci Mater Med. 19 (2008) 2889–2901. doi:10.1007/s10856-008-3437-y. [187] M. Mazzocchi, A. Bellosi, On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part I: processing, microstructure, mechanical properties, cytotoxicity, J. Mater. Sci. Mater. Med. 19 (2008) 2881–2887. doi:10.1007/s10856-008-3417-2. [188] J. Olofsson, M. Pettersson, N. Teuscher, A. Heilmann, K. Larsson, K. Grandfield, C. Persson, S. Jacobson, H. Engqvist, Fabrication and evaluation of SixNy coatings for total joint replacements, J Mater Sci Mater Med. 23 (2012) 1879–1889. doi:10.1007/s10856-012-4625-3. [189] M. Pettersson, T. Berlind, S. Schmidt, S. Jacobson, L. Hultman, C. Persson, H. Engqvist, Structure and composition of silicon nitride and silicon carbon nitride coatings for joint replacements, Surf. Coatings Technol. 235 (2013) 827–834. doi:http://dx.doi.org/10.1016/j.surfcoat.2013.09.008. [190] M. Pettersson, S. Tkachenko, S. Schmidt, T. Berlind, S. Jacobson, L. Hultman, H. Engqvist, C. Persson, Mechanical and tribological behavior of silicon nitride and silicon carbon nitride coatings for total joint replacements, J Mech Behav Biomed Mater. 25 (2013) 41–47. doi:10.1016/j.jmbbm.2013.05.002. [191] E. Laarz, B. V Zhmud, L. Bergström, Dissolution and Deagglomeration of Silicon Nitride in Aqueous Medium, J. Am. Ceram. Soc. 83 (2000) 2394–2400. doi:10.1111/j.1151-2916.2000.tb01567.x. [192] B. V Zhmud, L. Bergström, Dissolution Kinetics of Silicon Nitride in Aqueous Suspension, J. Colloid Interface Sci. 218 (1999) 582–584. doi:http://dx.doi.org/10.1006/jcis.1999.6425. [193] M. Pettersson, M. Bryant, S. Schmidt, H. Engqvist, R.M. Hall, A. Neville, C. Persson, Dissolution behaviour of silicon nitride coatings for joint replacements, Mater. Sci. Eng. C. (2016). doi:10.1016/j.msec.2016.01.049. [194] N. V Boskitskaya, T.S. Bartnitskaya, G.N. Makarenko, V.A. Lavrenko, N.M. Danilenko, N.P. Tel’nikova, Chemical stability of silicon nitride powders in biochemical media, Powder Metall. Met. Ceram. 35 (1996) 497–500. doi:10.1007/BF01355964. [195] R.M. Taylor, J.P. Bernero, A.A. Patel, D.S. Brodke, A.C. Khandkar, SILICON NITRIDE: A NEW MATERIAL FOR SPINAL IMPLANTS, J. Bone Jt. Surgery, Br. Vol. 92–B (2010) 133. http://www.bjjprocs.boneandjoint.org.uk/content/92-B/SUPP_I/133.1.abstract. [196] B.S. Bal, A. Khandkar, R. Lakshminarayanan, I. Clarke, A.A. Hoffman, M.N. Rahaman, Testing of silicon nitride ceramic bearings for total hip arthroplasty, J. Biomed. Mater. Res. Part B Appl. Biomater. 87B (2008) 447–454. doi:10.1002/jbm.b.31123. [197] A. Neumann, C. Unkel, C. Werry, C.U. Herborn, H.R. Maier, C. Ragoss, K. Jahnke, Prototype of a silicon nitride ceramic-based miniplate osteofixation system for the midface, Otolaryngol Head Neck Surg. 134 (2006) 923–930. doi:10.1016/j.otohns.2006.01.022. [198] T.G. Ma S.B., Biological Effects of Wear Debris from Joint Arthroplasties, in: P. Ducheyne (Ed.), Compr. Biomater., Elsevier, Oxford, 2011. [199] M. Navarro, A. Michiardi, O. Castaño, J.A. Planell, Biomaterials in orthopaedics., J. R. Soc. Interface. 5 (2008) 1137–58. doi:10.1098/rsif.2008.0151. [200] J. Fisher, X.Q. Hu, T.D. Stewart, S. Williams, J.L. Tipper, E. Ingham, M.H. Stone, C. Davies, P. Hatto, J. Bolton, M. Riley, C. Hardaker, G.H. Isaac, G. Berry, Wear of surface engineered metal-on-metal hip prostheses, J. Mater. Sci. Mater. Med. 15 (2004) 225–235. doi:10.1023/B:JMSM.0000015482.24542.76. [201] C.Y. Lin, H. Kang, J.P. Rouleau, S.J. Hollister, F.L. Marca, Stress analysis of the interface between cervical vertebrae end plates and the Bryan, Prestige LP, and ProDisc-C cervical disc prostheses: an in vivo image-based finite element study, Spine (Phila Pa 1976). 34 (2009) 1554–1560. doi:10.1097/BRS.0b013e3181aa643b. [202] International Organization for Standardization, ISO-7206-2:2011 - Implants for surgery -- Partial and total hip joint prostheses -- Part 2: Articulating surfaces made of metallic, ceramic and plastics materials, (2011). [203] S.A. Wenzel, D.E. Shepherd, Contact stresses in lumbar total disc arthroplasty, Biomed Mater Eng. 17 (2007) 169–173. [204] J.P. Clewlow, T. Pylios, D.E.T. Shepherd, Soft layer bearing joints for spine arthroplasty, Mater. Des. 29 (2008) 1981–1985. doi:http://dx.doi.org/10.1016/j.matdes.2008.04.008. [205] I.J. Udofia, Z.M. Jin, Elastohydrodynamic lubrication analysis of metal-on-metal hip-resurfacing prostheses, J Biomech. 36 (2003) 537–544. [206] T. Pylios, D.E. Shepherd, Soft layered concept in the design of metacarpophalangeal joint replacement implants, Biomed Mater Eng. 18 (2008) 73–82. [207] ASTM, ASTM Standard F1537-11, Stand. Specif. Wrought Cobalt-28Chromium-6Molybdenum Alloy. Surg. Implant. (UNS R31537, UNS R31538, UNS R31539). (2011). doi:10.1520/F1537-11. [208] A. Khan, J. Philip, P. Hess, Young’s modulus of silicon nitride used in scanning force microscope cantilevers, (n.d.). doi:10.1063/1.1638886͔. [209] J. Jagielski, A.S. Khanna, J. Kucinski, D.S. Mishra, P. Racolta, P. Sioshansi, E. Tobin, J. Thereska, V. Uglov, T. Vilaithong, J. Viviente, S.-Z. Yang, A. Zalar, Effect of chromium nitride coating on the corrosion and wear resistance of stainless steel, (n.d.). [210] L. Mattei, F. Di Puccio, B. Piccigallo, E. Ciulli, Lubrication and wear modelling of artificial hip joints: A review, Tribol. Int. 44 (2011) 532–549. doi:http://dx.doi.org/10.1016/j.triboint.2010.06.010. [211] S. Williams, D. Jalali-Vahid, C. Brockett, Z. Jin, M.H. Stone, E. Ingham, J. Fisher, Effect of swing phase load on metal-on-metal hip lubrication, friction and wear, J. Biomech. 39 (2006) 2274–2281. doi:10.1016/j.jbiomech.2005.07.011. [212] J.Q. Yao, M.P. Laurent, T.S. Johnson, C.R. Blanchard, R.D. Crowninshield, The influences of lubricant and material on polymer/CoCr sliding friction, Wear. 255 (2003) 780–784. doi:10.1016/S0043-1648(03)00180-7. [213] I.G. Goryacheva, Contact Mechanics in Tribology, Springer Netherlands, 2013. https://books.google.co.uk/books?id=G2zuCAAAQBAJ. [214] G.R. Johnson, 1 - Biomechanics of joints, in: P.A. Revell (Ed.), Jt. Replace. Technol., Woodhead Publishing, 2008: pp. 3–30. doi:http://dx.doi.org/10.1533/9781845694807.1.3. [215] B.J. Hamrock, D. Dowson, Elastohydrodynamic Lubrication of Elliptical Contacts for Materials of Low Elastic Modulus I—Fully Flooded Conjunction, J. Lubr. Technol. 100 (1978) 236–245. doi:10.1115/1.3453152. [216] H. Xin, D. Shepherd, K. Dearn, PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis, Open Biomed Eng J. 6 (2012) 73–79. doi:10.2174/1874230001206010073. [217] Arcam, ASTM F75 CoCr Alloy, 2015 (n.d.). http://www.arcam.com/wp-content/uploads/Arcam-ASTM-F75-Cobalt-Chrome.pdf. [218] M.Y.P. Costa, M.L.R. Venditti, M.O.H. Cioffi, H.J.C. Voorwald, V.A. Guimarães, R. Ruas, Fatigue behavior of PVD coated Ti–6Al–4V alloy, Int. J. Fatigue. 33 (2011) 759–765. doi:10.1016/j.ijfatigue.2010.11.007. [219] K. Ando, M.C. Chu, F. Yao, S. Sato, Fatigue strength of crack-healed Si3N4/SiC composite ceramics, Fatigue <html_ent Glyph=“@amp;” ascii=“&”/> Fract. Eng. Mater. Struct. 22 (1999) 897–903. doi:10.1046/j.1460-2695.1999.00210.x. [220] M. Bushelow, W. Nechtow, J. Walker, P8. Metal-on-Metal Lumbar TDR Design: A Theoretical Analysis of the Affect of Diameter Clearance and Surface Finish on Lubrication, Spine J. 8 (2008) 105S. doi:10.1016/j.spinee.2008.06.650. [221] Z.M. Jin, D. Dowson, A full numerical analysis of hydrodynamic lubrication in artificial hip joint replacements constructed from hard materials, Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 213 (1999) 355–370. doi:10.1243/0954406991522310. [222] D. Dowson, C.M. McNie, A.A.J. Goldsmith, Direct experimental evidence of lubrication in a metal-on-metal total hip replacement tested in a joint simulator, Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 214 (2000) 75–86. doi:10.1243/0954406001522822. [223] Z.M. Jin, D. Dowson, J. Fisher, Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus, Proc Inst Mech Eng H. 211 (1997) 247–256. [224] D. Dowson, Basic Tribology, in: D.W. Dowson V (Ed.), An Introd. to Biomech. Joints Jt. Replace., Mechl Eng Publications Limited, London, 1981: pp. 49–60. [225] R. Sonntag, J. Reinders, J.S. Rieger, D.W.W. Heitzmann, J.P. Kretzer, Hard-on-Hard Lubrication in the Artificial Hip under Dynamic Loading Conditions, PLoS One. 8 (2013) e71622. doi:10.1371/journal.pone.0071622. [226] Z.M. Jin, J. Fisher, E. Ingham, Biotribology: Material Design, Lubrication and Wear in Artificial Hip Joints, in: Handb. Lubr. Tribol. Vol. I Appl. Maint., CRC Press, Boca Raton, FL, 2006. [227] D. Dowson, Tribological principles in metal-on-metal hip joint design, Proc Inst Mech Eng H. 220 (2006) 161–171. [228] S.C. Scholes, A. Unsworth, Comparison of friction and lubrication of different hip prostheses, Proc Inst Mech Eng H. 214 (2000) 49–57. [229] S. Zhang, F. Awaja, N. James, D.R. McKenzie, A.J. Ruys, Autohesion of plasma treated semi-crystalline PEEK: Comparative study of argon, nitrogen and oxygen treatments, Colloids Surfaces A Physicochem. Eng. Asp. 374 (2011) 88–95. doi:10.1016/j.colsurfa.2010.11.013. [230] C.-C. Sun, S.-C. Lee, W.-C. Hwang, J.-S. Hwang, I.-T. Tang, Y.-S. Fu, Surface Free Energy of Alloy Nitride Coatings Deposited Using Closed Field Unbalanced Magnetron Sputter Ion Plating, Mater. Trans. 47 (2006) 2533–2539. doi:10.2320/matertrans.47.2533. [231] K. Midtbø, K. Schjølberg-Henriksen, M.M. V Taklo, A. Rønnekleiv, Surface Energy of Fusion Bonded Silicon Nitride to Silicon, (n.d.). http://ma.ecsdl.org/content/MA2005-01/11/519.full.pdf (accessed July 12, 2017). [232] Y. Yan, H. Yang, Y. Su, L. Qiao, Albumin adsorption on CoCrMo alloy surfaces., Sci. Rep. 5 (2015) 18403. doi:10.1038/srep18403. [233] M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, J.J. Jacobs, Tribochemical Reactions in Metal-on-Metal Hip Joints Influence Wear and Corrosion, (2012) 1–18. doi:10.1520/STP156020120050. [234] H. Dong, Y. Nagamatsu, K.-K. Chen, K. Tajima, H. Kakigawa, S. Shi, Y. Kozono, Corrosion behavior of dental alloys in various types of electrolyzed water., Dent. Mater. J. 22 (2003) 482–93. http://www.ncbi.nlm.nih.gov/pubmed/15005226 (accessed February 20, 2017). [235] M.T. Clarke, P.T.H. Lee, A. Arora, R.N. Villar, Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty, Bone Joint J. 85–B (2003). [236] H.P. Sieber, C.B. Rieker, P. Kottig, Analysis of 118 second-generation metal-on-metal retrieved hip implants, J Bone Jt. Surg Br. 81 (1999) 46–50. [237] J.L. Gilbert, C.A. Buckley, J.J. Jacobs, In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling, J. Biomed. Mater. Res. 27 (1993) 1533–1544. doi:10.1002/jbm.820271210. [238] G. Manivasagam, D. Dhinasekaran, A. Rajamanickam, Biomedical Implants: Corrosion and its Prevention -A Review, Recent Patents Corros. Sci. 2 (2010) 40–54. [239] H. Matusiewicz, Potential release of in vivo trace metals from metallic medical implants in the human body: From ions to nanoparticles – A systematic analytical review, Acta Biomater. 10 (2014) 2379–2403. doi:10.1016/j.actbio.2014.02.027. [240] D. Ladon, A. Doherty, R. Newson, J. Turner, M. Bhamra, C.P. Case, Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty, J Arthroplast. 19 (2004) 78–83. [241] H. Pandit, S. Glyn-Jones, P. McLardy-Smith, R. Gundle, D. Whitwell, C.L. Gibbons, S. Ostlere, N. Athanasou, H.S. Gill, D.W. Murray, Pseudotumours associated with metal-on-metal hip resurfacings, J Bone Jt. Surg Br. 90 (2008) 847–851. doi:10.1302/0301-620X.90B7.20213. [242] J. Gallo, S.B. Goodman, Y.T. Konttinen, M. Raska, Particle disease: biologic mechanisms of periprosthetic osteolysis in total hip arthroplasty., Innate Immun. 19 (2013) 213–24. doi:10.1177/1753425912451779. [243] N. Taki, J.M. Tatro, J.L. Nalepka, D. Togawa, V.M. Goldberg, C.M. Rimnac, E.M. Greenfield, Polyethylene and titanium particles induce osteolysis by similar, lymphocyte-independent, mechanisms, J. Orthop. Res. 23 (2005) 376–383. doi:10.1016/j.orthres.2004.08.023. [244] R.P. Van Hove, I.N. Sierevelt, B.J. Van Royen, P.A. Nolte, Titanium-Nitride Coating of Orthopaedic Implants: A Review of the Literature, Biomed Res. Int. 2015 (2015) 1–9. doi:10.1155/2015/485975. [245] J. Olofsson, T.M. Grehk, T. Berlind, C. Persson, S. Jacobson, H. Engqvist, Evaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement, Biomatter. 2 (2012) 94–102. doi:10.4161/biom.20710. [246] B.S. Bal, M.N. Rahaman, Orthopedic applications of silicon nitride ceramics, Acta Biomater. 8 (2012) 2889–2898. doi:http://dx.doi.org/10.1016/j.actbio.2012.04.031. [247] A. Neumann, C. Unkel, C. Werry, C.U. Herborn, H.R. Maier, C. Ragoss, K. Jahnke, [Osteosynthesis in facial bones: silicon nitride ceramic as material], HNO. 54 (2006) 937–942. doi:10.1007/s00106-006-1397-4. [248] A. Corp, First Silicon Nitride Total Hip Replacement, 2013 (2011). http://www.amedicacorp.com/press_releases/amedica_us_spine_enters_the_reconstructive_surgery_market. [249] International Organization for Standardization, ISO-4288:1996 - Geometrical Product Specifications (GPS) -- Surface texture: Profile method -- Rules and procedures for the assessment of surface texture, (1996). [250] International Organization for Standardization, BS EN ISO-3274:1998 - Geometric product specifications (GPS). Surface texture. Profile method. Nominal characteristics of contact (stylus) instruments, (1998). [251] International Organization for Standardization, BS EN ISO-26423:2016 - Fine ceramics (advanced ceramics, advanced technical ceramics). Determination of coating thickness by crater-grinding method, (n.d.). http://shop.bsigroup.com/ProductDetail/?pid=000000000030327990 (accessed February 25, 2017). [252] I.N. Sneddon, The relation between load and penetration in the axisymmetric boussinesq problem for a punch of arbitrary profile, Int. J. Eng. Sci. 3 (1965) 47–57. doi:10.1016/0020-7225(65)90019-4. [253] W.C. Oliver, G.M. Pharr, An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments, J. Mater. Res. 7 (1992) 1564–1583. doi:doi:10.1557/JMR.1992.1564. [254] Heavens, O.S., Some factors influencing the adhesion of films produced by vacuum evaporation, J. Phys. Radium. 11 (1950) 355–360. doi:10.1051/jphysrad:01950001107035500. [255] P. Benjamin, C. Weaver, Measurement of Adhesion of Thin Films, Proc. R. Soc. London. Ser. A. Math. Phys. Sci. 254 (1960) 163 LP-176. http://rspa.royalsocietypublishing.org/content/254/1277/163.abstract. [256] International Organization for Standardization, BS EN 1071-2:2002 - Advanced technical ceramics. Methods of test for ceramic coatings. Determination of coating thickness by the crater grinding method, (n.d.). http://shop.bsigroup.com/ProductDetail/?pid=000000000030115576 (accessed February 25, 2017). [257] H.A. Ching, D. Choudhury, M.J. Nine, N.A. Abu Osman, Effects of surface coating on reducing friction and wear of orthopaedic implants, Sci. Technol. Adv. Mater. 15 (2014) 14402. doi:10.1088/1468-6996/15/1/014402. [258] A.. Ehiasarian, W.-D. Münz, L. Hultman, U. Helmersson, I. Petrov, High power pulsed magnetron sputtered CrNx films, Surf. Coatings Technol. 163–164 (2003) 267–272. doi:10.1016/S0257-8972(02)00479-6. [259] A.. Ehiasarian, P.E. Hovsepian, L. Hultman, U. Helmersson, Comparison of microstructure and mechanical properties of chromium nitride-based coatings deposited by high power impulse magnetron sputtering and by the combined steered cathodic arc/unbalanced magnetron technique, Thin Solid Films. 457 (2004) 270–277. doi:10.1016/j.tsf.2003.11.113. [260] A. Anders, Tutorial: Reactive high power impulse magnetron sputtering (R-HiPIMS), J. Appl. Phys. 121 (2017) 171101. doi:10.1063/1.4978350. [261] P. Hones, R. Sanjines, F. Levy, Characterization of sputter-deposited chromium nitride thin films for hard coatings, Surf. Coatings Technol. 94–95 (1997) 398–402. doi:10.1016/S0257-8972(97)00443-X. [262] E. Broszeit, C. Friedrich, G. Berg, Deposition, properties and applications of PVD CrxN coatings, Surf. Coatings Technol. 115 (1999) 9–16. doi:10.1016/S0257-8972(99)00021-3. [263] A. Lippitz, T. Hübert, XPS investigations of chromium nitride thin films, Surf. Coatings Technol. 200 (2005) 250–253. doi:http://dx.doi.org/10.1016/j.surfcoat.2005.02.091. [264] L. Diéguez, D. Caballero, J. Calderer, M. Moreno, E. Martínez, J. Samitier, Optical Gratings Coated with Thin Si3N4 Layer for Efficient Immunosensing by Optical Waveguide Lightmode Spectroscopy., Biosensors. 2 (2012) 114–26. doi:10.3390/bios2020114. [265] I.O. for Standarisation, Partial and total hip joint prostheses -- Part 2: Articulating surfaces made of metallic, ceramic and plastics materials, Implant. Surg. 7206–2:201 (2011). [266] M. Pettersson, Silicon nitride for total hip replacements, 2015. https://uu.diva-portal.org/smash/get/diva2:797505/FULLTEXT01.pdf (accessed June 4, 2017). [267] F. Zhou, K. Adachi, K. Kato, Influence of deposition parameters on surface roughness and mechanical properties of boron carbon nitride coatings synthesized by ion beam assisted deposition, Thin Solid Films. 497 (2006) 210–217. doi:10.1016/j.tsf.2005.10.070. [268] D.M. Mattox, Handbook of physical vapor deposition (PVD) processing, Noyes Publications, Westwood, New Jersey, USA, 2010. https://books.google.co.uk/books?id=BZUtFQNuNgMC&pg=PA157&lpg=PA157&dq=physical+vapour+deposition+process+position+in+the+chamber&source=bl&ots=PHFirQn4S5&sig=uM693uVER0aLXTYJR-sqZTCoeW4&hl=en&sa=X&ved=0ahUKEwi1mPf0kqTUAhXsJcAKHZMMCTsQ6AEIYDAJ#v=onepage&q (accessed June 4, 2017). [269] C. Fabry, C. Zietz, A. Baumann, R. Bader, Wear Performance of Sequentially Cross-Linked Polyethylene Inserts against Ion-Treated CoCr, TiNbN-Coated CoCr and Al2O3 Ceramic Femoral Heads for Total Hip Replacement, Lubricants. 3 (2015) 14–26. doi:10.3390/lubricants3010014. [270] Aesculap Orthopaedics Columbus ® AS Knee System, (2009). https://www.aesculapimplantsystems.com/assets/base/doc/doc832-askneebrochure.pdf (accessed June 4, 2017). [271] T. Halim, I.C. Clarke, M.D. Burgett-Moreno, T.K. Donaldson, C. Savisaar, J.G. Bowsher, A simulator study of adverse wear with metal and cement debris contamination in metal-on-metal hip bearings., Bone Joint Res. 4 (2014) 29–37. doi:10.1302/2046-3758.43.2000332. [272] C.R. Bragdon, M. Jasty, O.K. Muratoglu, W.H. Harris, Third-Body Wear Testing of a Highly Cross-Linked Acetabular Liner, J. Arthroplasty. 20 (2005) 379–385. doi:10.1016/j.arth.2004.09.035. [273] S.G. Ghalme, A. Mankar, Y. Bhalerao, Biomaterials in Hip Joint Replacement, Int. J. Mater. Sci. Eng. 4 (2016). doi:10.17706/ijmse.2016.4.2.113-125. [274] J. Lackner, W. Waldhauser, L. Major, M. Kot, Tribology and Micromechanics of Chromium Nitride Based Multilayer Coatings on Soft and Hard Substrates, Coatings. 4 (2014) 121–138. doi:10.3390/coatings4010121. [275] L. Cunha, M. Andritschky, K. Pischow, Z. Wang, A. Zarychta, A.S. Miranda, A.M. Cunha, Performance of chromium nitride based coatings under plastic processing conditions, Surf. Coatings Technol. 133 (2000) 61–67. doi:10.1016/S0257-8972(00)00875-6. [276] A. Leyland, A. Matthews, On the significance of the H/E ratio in wear control: a nanocomposite coating approach to optimised tribological behaviour, Wear. 246 (2000) 1–11. doi:10.1016/S0043-1648(00)00488-9. [277] A.A.C. Recco, I.C. Oliveira, M. Massi, H.S. Maciel, A.P. Tschiptschin, Adhesion of reactive magnetron sputtered TINx and TICy coatings to AISI H13 tool steel, Surf. Coatings Technol. 202 (2007) 1078–1083. doi:10.1016/j.surfcoat.2007.07.073. [278] H. Haider, J.N. Weisenburger, F. Namavar, K.L. Garvin, Why We Need Coating Technologies for Hip Replacement Systems, and the Importance of Testing them in Vitro, Oper. Tech. Orthop. (2017). doi:10.1053/j.oto.2017.05.003. [279] Ł. Łapaj, J. Markuszewski, J. Wendland, A. Mróz, M. Wierusz-Kozłowska, Massive failure of TiNbN coating in surface engineered metal-on-metal hip arthroplasty: Retrieval analysis, J. Biomed. Mater. Res. Part B Appl. Biomater. 104 (2016) 1043–1049. doi:10.1002/jbm.b.33421. [280] S. Jiang, B. Jiang, Y. Li, Y. Li, G. Yin, C. Zheng, Friction and wear study of diamond-like carbon gradient coatings on Ti6Al4V substrate prepared by plasma source ion implant-ion beam enhanced deposition, Appl. Surf. Sci. 236 (2004) 285–291. doi:10.1016/j.apsusc.2004.04.032. [281] W. Heinke, A. Leyland, A. Matthews, G. Berg, C. Friedrich, E. Broszeit, Evaluation of PVD nitride coatings, using impact, scratch and Rockwell-C adhesion tests, Thin Solid Films. 270 (1995) 431–438. doi:10.1016/0040-6090(95)06934-8. [282] H. Ollendorf, D. Schneider, A comparative study of adhesion test methods for hard coatings, Surf. Coatings Technol. 113 (1999) 86–102. doi:10.1016/S0257-8972(98)00827-5. [283] Z. Wan, T.F. Zhang, H.-B.-R. Lee, J.H. Yang, W.C. Choi, B. Han, K.H. Kim, S.-H. Kwon, Improved Corrosion Resistance and Mechanical Properties of CrN Hard Coatings with an Atomic Layer Deposited Al2O3 Interlayer, ACS Appl. Mater. Interfaces. 7 (2015) 26716–26725. doi:10.1021/acsami.5b08696. [284] K.-D. Bouzakis, S. Makrimallakis, G. Katirtzoglou, G. Skordaris, S. Gerardis, E. Bouzakis, T. Leyendecker, S. Bolz, W. Koelker, Surface & coatings technology., Surf. Coatings Technol. 205 (2010) 1564–1570. http://publica.fraunhofer.de/documents/N-171875.html (accessed June 10, 2017). [285] E. Adoberg, V. Podgurski, P. Peetsalu, L. Lind, V. Mikli, P. Hvizdos, P. Kulu, The effect of surface pre-treatment and coating post-treatment to the properties of TiN coatings, Est. J. Eng. 18 (2012) 185–192. doi:10.3176/eng.2012.3.03. [286] M. Melancon Paul Hunter, A. Al-Borno, T. Liskiewicz, S. Rao Bassem Salamah Shailesh Dhoke, J. Cortes Xianyi Chen, The Effect of Four Commercially Available Steel Decontamination Processes on the Performance of External Coatings, in: NACE - Int. Corros. Conf. Ser., National Association of Corrosion Engineers International, San Antonio, 2014. http://eprints.whiterose.ac.uk/84172/1/NACE 2014 Paper 4391 External Coatings - Jan 30 2014.pdf (accessed June 10, 2017). [287] H.-G. Willert, G.H. Buchhorn, A. Fayyazi, R. Flury, M. Windler, G. Köster, C.H. Lohmann, Metal-on-Metal Bearings and Hypersensitivity in Patients with Artificial Hip Joints<sbt aid=\"954276\">A Clinical and Histomorphological Study</sbt>, J. Bone Jt. Surg. 87 (2005) 28. doi:10.2106/JBJS.A.02039pp. [288] P. Campbell, E. Ebramzadeh, S. Nelson, K. Takamura, K. De Smet, H.C. Amstutz, Histological Features of Pseudotumor-like Tissues From Metal-on-Metal Hips, Clin. Orthop. Relat. Res. 468 (2010) 2321–2327. doi:10.1007/s11999-010-1372-y. [289] I.J. Leslie, S. Williams, C. Brown, J. Anderson, G. Isaac, P. Hatto, E. Ingham, J. Fisher, Surface engineering: A low wearing solution for metal-on-metal hip surface replacements, J. Biomed. Mater. Res. Part B Appl. Biomater. 90B (2009) 558–565. doi:10.1002/jbm.b.31317. [290] R. Lappalainen, M. Selenius, P.A. Revell, Joint bearing surfaces and replacement joint design, in: P.A. Revell (Ed.), Jt. Replace. Technol., Woodhead Publishing Limited Cambridge, UK, Cambridge, 2008. [291] J. Nevelos, E. Ingham, C. Doyle, R. Streicher, A. Nevelos, W. Walter, J. Fisher, Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns, J Arthroplast. 15 (2000) 7–795. doi:10.1054/arth.2000.8100. [292] A. Essner, G. Schmidig, A. Wang, The clinical relevance of hip joint simulator testing: In vitro and in vivo comparisons, 2005. doi:10.1016/j.wear.2005.02.105. [293] P.J. Firkins, J.L. Tipper, M.R. Saadatzadeh, E. Ingham, M.H. Stone, R. Farrar, J. Fisher, Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator., Biomed. Mater. Eng. 11 (2001) 143–57. http://www.ncbi.nlm.nih.gov/pubmed/11352113 (accessed March 20, 2017). [294] J.L. Tipper, A. Hatton, J.E. Nevelos, E. Ingham, C. Doyle, R. Streicher, A.B. Nevelos, J. Fisher, Alumina–alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations, Biomaterials. 23 (2002) 3441–3448. doi:10.1016/S0142-9612(02)00048-0. [295] A. Wang, A. Essner, Three-body wear of UHMWPE acetabular cups by PMMA particles against CoCr, alumina and zirconia heads in a hip joint simulator, Wear. 250 (2001) 212–216. doi:http://dx.doi.org/10.1016/S0043-1648(01)00643-3. [296] C. Myant, R. Underwood, J. Fan, P.M. Cann, Lubrication of metal-on-metal hip joints: the effect of protein content and load on film formation and wear, J Mech Behav Biomed Mater. 6 (2012) 30–40. doi:10.1016/j.jmbbm.2011.09.008. [297] J. Lefebvre, Viscosity of concentrated protein solutions, Rheol. Acta. 21 (n.d.) 620–625. doi:10.1007/bf01534361. [298] S.C. Scholes, A. Unsworth, The effects of proteins on the friction and lubrication of artificial joints, Proc Inst Mech Eng H. 220 (2006) 687–693. [299] S.M. Kurtz, A.A. Edidin, Spine technology handbook, (2006) xiv, 535 ill. (some col.) 25 cm. http://0-www.engineeringvillage.com.wam.leeds.ac.uk/controller/servlet/OpenURL?genre=book&isbn=9780123693907. [300] P. Moghadas, A. Mahomed, D.W.L. Hukins, D.E.T. Shepherd, Wear in metal-on-metal total disc arthroplasty., Proc. Inst. Mech. Eng. H. 227 (2013) 356–61. doi:10.1177/0954411912471768. [301] T.M. Grupp, H.-J. Meisel, J.A. Cotton, J. Schwiesau, B. Fritz, W. Blömer, V. Jansson, Alternative bearing materials for intervertebral disc arthroplasty, Biomaterials. 31 (2010) 523–531. doi:10.1016/j.biomaterials.2009.09.064. [302] M. Kraft, D. Koch, M. Bushelow, Evaluation of PEEK-on-PEEK as a New Articulation, in: Annu. Meet. Ger. Spine Soc., Hamburg, 2011. http://www.medicalpeek.org/pub_reports/view/143 (accessed April 8, 2017). [303] R. Vicars, P. Prokopovich, T.D. Brown, J.L. Tipper, E. Ingham, J. Fisher, R.M. Hall, The effect of anterior-posterior shear on the wear of CHARITÉ total disc replacement., Spine (Phila. Pa. 1976). 37 (2012) E528-34. doi:10.1097/BRS.0b013e31823cbd6e. [304] P. Moghadas, A. Mahomed, D.E. Shepherd, D.W. Hukins, Wear of the Charité ® lumbar intervertebral disc replacement investigated using an electro-mechanical spine simulator, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 229 (2015) 264–268. doi:10.1177/0954411915576537. [305] P. Prokopovich, S. Perni, J. Fisher, R.M. Hall, Spatial variation of wear on Charité lumbar discs, Acta Biomater. 7 (2011) 3914–3926. doi:10.1016/j.actbio.2011.06.036. [306] F.W. Chan, J.D. Bobyn, J.B. Medley, J.J. Krygier, M. Tanzer, The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants., Clin. Orthop. Relat. Res. (1999) 10–24. http://www.ncbi.nlm.nih.gov/pubmed/10611857 (accessed April 8, 2017). [307] A.A.J. Goldsmith, D. Dowson, G.H. Isaac, J.G. Lancaster, A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 214 (2000) 39–47. doi:10.1243/0954411001535228. [308] G.H. Isaac, J. Thompson, S. Williams, J. Fisher, Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 220 (2006) 119–133. doi:10.1243/095441105X68953. [309] C. Duc, P. Salvia, A. Lubansu, V. Feipel, K. Aminian, Objective evaluation of cervical spine mobility after surgery during free-living activity, Clin. Biomech. 28 (2013) 364–369. doi:10.1016/j.clinbiomech.2013.03.006. [310] M. Al-Hajjar, J. Fisher, S. Williams, J.L. Tipper, L.M. Jennings, Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions, J Biomed Mater Res Part B Appl Biomater J Biomed Mater Res Part B. 101101 (2013). doi:10.1002/jbm.b.32824. [311] C. Klapperich, J. Graham, L. Pruitt, M.D. Ries, Failure of a Metal-on-Metal Total Hip Arthroplasty From Progressive Osteolysis, J. Arthroplasty. 14 (1999). http://www.ewp.rpi.edu/hartford/~ernesto/F2012/FWM/Papers/Klapperich-1999-Total-Hip.pdf (accessed April 9, 2017). [312] A. Wang, S. Yue, J.. Bobyn, F.. Chan, J.. Medley, Surface characterization of metal-on-metal hip implants tested in a hip simulator, Wear. 225 (1999) 708–715. doi:10.1016/S0043-1648(98)00384-6. [313] T.J. Joyce, H. Grigg, D.J. Langton, A.V.F. Nargol, Quantification of self-polishing in vivo from explanted metal-on-metal total hip replacements, Tribol. Int. 44 (2011) 513–516. doi:10.1016/j.triboint.2010.04.007. [314] M.L. Scott, J.I. Partin, Reduced Wear Rates and Tribological Properties of Long-Term Retrieved Metal-on-Metal Tha Bearing Components, in: Proc. 45th Meet. Orthop. Res. Soc., Anaheim, California, 1999: p. 851. http://www.ors.org/Transactions/45/0851.PDF (accessed April 9, 2017). [315] P.J. Firkins, J.L. Tipper, M.R. Saadatzadeh, E. Ingham, M.H. Stone, R. Farrar, J. Fisher, Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator., Biomed. Mater. Eng. 11 (2001) 143–57. http://www.ncbi.nlm.nih.gov/pubmed/11352113 (accessed April 8, 2017). [316] K. Vassiliou, A.P. D Elfick, S.C. Scholes, A. Unsworth, The effect of “running-in” on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 220 (2006) 269–277. doi:10.1243/09544119JEIM63. [317] J.L. Tipper, P.J. Firkins, E. Ingham, J. Fisher, M.H. Stone, R. Farrar, Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements., J. Mater. Sci. Mater. Med. 10 (1999) 353–62. http://www.ncbi.nlm.nih.gov/pubmed/15348136 (accessed March 20, 2017). [318] D.S. Park, S. Danyluk, M.J. McNallan, Influence of Tribochemical Reaction Products on Friction and Wear of Silicon Nitride at Elevated Temperatures in Reactive Environments, J. Am. Ceram. Soc. 75 (1992) 3033–3039. doi:10.1111/j.1151-2916.1992.tb04383.x. [319] D. Amutha Rani, Y. Yoshizawa, M.I. Jones, H. Hyuga, K. Hirao, Y. Yamauchi, Comparison of Tribological Behavior Between α-Sialon/Si3N4 and Si3N4/Si3N4 Sliding Pairs in Water Lubrication, J. Am. Ceram. Soc. 88 (2005) 1655–1658. doi:10.1111/j.1551-2916.2005.00274.x. [320] T. Saito, Y. Imada, F. Honda, An analytical observation of the tribochemical reaction of silicon nitride sliding with low friction in aqueous solutions, Wear. 205 (1997) 153–159. doi:http://dx.doi.org/10.1016/S0043-1648(96)07287-0. [321] J. Xu, K. Kato, Formation of tribochemical layer of ceramics sliding in water and its role for low friction, Wear. 245 (2000) 61–75. doi:http://dx.doi.org/10.1016/S0043-1648(00)00466-X. [322] H.A. Richardson, I.C. Clarke, P. Williams, T. Donaldson, H. Oonishi, Precision and accuracy in ceramic-on-ceramic wear analyses: influence of simulator test duration, Proc Inst Mech Eng H. 219 (2005) 401–405. [323] I.C. Clarke, V. Good, P. Williams, D. Schroeder, L. Anissian, A. Stark, H. Oonishi, J. Schuldies, G. Gustafson, Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements, Proc Inst Mech Eng H. 214 (2000) 331–347. [324] H. Oonishi, I.C. Clarke, V. Good, H. Amino, M. Ueno, Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model, J Biomed Mater Res A. 70 (2004) 523–532. doi:10.1002/jbm.a.30021. [325] B.J. McEntire, B.S. Bal, A. Lakshminarayanan, R. Bock, Silicon Nitride Bearings for Total Joint Arthroplasty, Lubricants. 4 (2016) 1–24. doi:10.3390/lubricants4040035. [326] B.S. Bal, A. Khandkar, R. Lakshminarayanan, I. Clarke, A.A. Hoffman, M.N. Rahaman, Fabrication and Testing of Silicon Nitride Bearings in Total Hip Arthroplasty: Winner of the 2007 “HAP” PAUL Award, J Arthroplast. 24 (2009) 110–116. doi:http://dx.doi.org/10.1016/j.arth.2008.01.300. [327] F. Liu, I.J. Udofia, Z.M. Jin, F. Hirt, C. Rieker, P. Roberts, P. Grigoris, Comparison of Contact Mechanics between a Total Hip Replacement and a Hip Resurfacing with a Metal-On-Metal Articulation, Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 219 (2005) 727–732. doi:10.1243/095440605X31490. [328] M. Royle, Influence of coatings on ion release from large diameter metal-on-metal hip bearings, Queen Mary, University of London, 2012. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.561233 (accessed April 21, 2017). [329] J.A. Ortega-Saenz, M. Alvarez-Vera, M.A.L. Hernandez-Rodriguez, Biotribological study of multilayer coated metal-on-metal hip prostheses in a hip joint simulator, Wear. 301 (2013) 234–242. doi:10.1016/j.wear.2013.01.024. [330] A. Mohammed, A. Metcalfe, D. Woodnutt, Medium-term outcome of titanium nitride, mobile bearing total knee replacement., Acta Orthop. Belg. 80 (2014) 269–75. http://www.ncbi.nlm.nih.gov/pubmed/25090802 (accessed April 21, 2017). [331] D. Woodnutt, K. Hamelynck, Low metal ion release in patients at up to 8 years following titanium niobium nitride (TiNbN) surface treated metal-on-metal hip arthroplasty, Orthop. Proc. 94–B (2012). http://www.bjjprocs.boneandjoint.org.uk/content/94-B/SUPP_XXXIX/6 (accessed April 21, 2017). [332] D. de Villiers, H. Hothi, H. Khatkar, J. Meswania, G. Blunn, J. Skinner, A. Hart, Lessons from retrievals: Retrievals help understand the reason for revision of coated hip arthroplasties, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 229 (2015) 804–811. doi:10.1177/0954411915611427. [333] P. Bergschmidt, R. Bader, S. Finze, C. Schulze, G. Kundt, W. Mittelmeier, Comparative Study of Clinical and Radiological Outcomes of Unconstrained Bicondylar Total Knee Endoprostheses with Anti-allergic Coating., Open Orthop. J. 5 (2011) 354–60. doi:10.2174/1874325001105010354. [334] A. Miletić, P. Terek, L. Kovačević, M. Vilotić, D. Kakaš, B. Škorić, D. Kukuruzović, Influence of substrate roughness on adhesion of TiN coatings, J. Brazilian Soc. Mech. Sci. Eng. 36 (2014) 293–299. doi:10.1007/s40430-013-0102-2. [335] N. Ravi, R. Markandeya, S. V. Joshi, Effect of substrate roughness on adhesion and tribological properties of nc-TiAlN/a-Si3N4 nanocomposite coatings deposited by cathodic arc PVD process, Surf. Eng. 33 (2017) 7–19. doi:10.1179/1743294415Y.0000000005. [336] M. Belmonte, A.J.S. Fernandes, F.M. Costa, F.J. Oliveira, R.F. Silva, Adhesion behaviour assessment on diamond coated silicon nitride by acoustic emission, Diam. Relat. Mater. 12 (2003) 733–737. doi:10.1016/S0925-9635(02)00305-9. [337] N.I. and the I. of M. National Joint Registry for England, Wales, 13th Annual Report - 2016, n.d. http://www.njrcentre.org.uk/njrcentre/Portals/0/Documents/England/Reports/13th Annual Report/07950 NJR Annual Report 2016 ONLINE REPORT.pdf (accessed March 26, 2017). [338] P.E. Purdue, P. Koulouvaris, B.J. Nestor, T.P. Sculco, The central role of wear debris in periprosthetic osteolysis., HSS J. 2 (2006) 102–13. doi:10.1007/s11420-006-9003-6. [339] W.J. Maloney, R.L. Smith, Periprosthetic osteolysis in total hip arthroplasty: the role of particulate wear debris., Instr. Course Lect. 45 (1996) 171–82. http://www.ncbi.nlm.nih.gov/pubmed/8727736 (accessed March 26, 2017). [340] S.-Y. Yang, W. Ren, Y. Park, A. Sieving, S. Hsu, S. Nasser, P.H. Wooley, Diverse cellular and apoptotic responses to variant shapes of UHMWPE particles in a murine model of inflammation., Biomaterials. 23 (2002) 3535–43. http://www.ncbi.nlm.nih.gov/pubmed/12109677 (accessed March 26, 2017). [341] M. Nine, D. Choudhury, A. Hee, R. Mootanah, N. Osman, Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints, Materials (Basel). 7 (2014) 980–1016. doi:10.3390/ma7020980. [342] M.S. Caicedo, L. Samelko, K. McAllister, J.J. Jacobs, N.J. Hallab, Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms, J. Orthop. Res. 31 (2013) 1633–1642. doi:10.1002/jor.22411. [343] R.S. Tuan, F.Y.-I. Lee, Y. T Konttinen, J.M. Wilkinson, R.L. Smith, Implant Wear Symposium 2007 Biologic Work Group, What are the local and systemic biologic reactions and mediators to wear debris, and what host factors determine or modulate the biologic response to wear particles?, J. Am. Acad. Orthop. Surg. 16 Suppl 1 (2008) S42-8. http://www.ncbi.nlm.nih.gov/pubmed/18612013 (accessed March 28, 2017). [344] V. Sansone, D. Pagani, M. Melato, The effects on bone cells of metal ions released from orthopaedic implants. A review., Clin. Cases Miner. Bone Metab. 10 (2013) 34–40. doi:10.11138/ccmbm/2013.10.1.034. [345] N.J. Hallab, J.J. Jacobs, Biologic effects of implant debris., Bull. NYU Hosp. Jt. Dis. 67 (2009) 182–8. http://www.ncbi.nlm.nih.gov/pubmed/19583551 (accessed March 26, 2017). [346] I. Catelas, J.J. Jacobs, Biologic activity of wear particles., Instr. Course Lect. 59 (2010) 3–16. http://www.ncbi.nlm.nih.gov/pubmed/20415362 (accessed March 28, 2017). [347] T.S. Watters, D.M. Cardona, K.S. Menon, E.N. Vinson, M.P. Bolognesi, L.G. Dodd, Aseptic Lymphocyte-Dominated Vasculitis-Associated Lesion, Am. J. Clin. Pathol. 134 (2010) 886–893. doi:10.1309/AJCPLTNEUAH8XI4W. [348] H.S. Gill, G. Grammatopoulos, S. Adshead, E. Tsialogiannis, E. Tsiridis, Molecular and immune toxicity of CoCr nanoparticles in MoM hip arthroplasty, Trends Mol Med. 18 (2012) 145–155. doi:10.1016/j.molmed.2011.12.002. [349] J.A. D’Antonio, W.N. Capello, M. Naughton, Ceramic bearings for total hip arthroplasty have high survivorship at 10 years, Clin Orthop Relat Res. 470 (2012) 373–381. doi:10.1007/s11999-011-2076-7. [350] D.G. Kang, S.C. Wagner, R.A. Lehman, Osteolysis in the setting of metal-on-metal cervical disc arthroplasty, Spine J. 14 (2014) 1362–1365. doi:10.1016/j.spinee.2014.02.034. [351] S.C. Scholes, A. Unsworth, Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples, J. Mater. Sci. Mater. Med. 12 (2001) 299–303. doi:10.1023/A:1011238902803. [352] International Organization for Standardization, ISO-10993-5:2009 - Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity., (2009). [353] S. Lal, R.M. Hall, J.L. Tipper, A novel method for isolation and recovery of ceramic nanoparticles and metal wear debris from serum lubricants at ultra-low wear rates, Acta Biomater. 42 (2016) 420–428. doi:10.1016/j.actbio.2016.07.004. [354] B. Behl, I. Papageorgiou, C. Brown, R. Hall, J.L. Tipper, J. Fisher, E. Ingham, Biological effects of cobalt-chromium nanoparticles and ions on dural fibroblasts and dural epithelial cells, Biomaterials. 34 (2013) 3547–3558. doi:10.1016/j.biomaterials.2013.01.023. [355] F. Lu, M. Royle, F. V Lali, A.J. Hart, S. Collins, J. Housden, J.C. Shelton, Simple isolation method for the bulk isolation of wear particles from metal on metal bearing surfaces generated in a hip simulator test, J. Mater. Sci. Mater. Med. 23 (2012) 891–901. doi:10.1007/s10856-012-4573-y. [356] K. Ohlendieck, Centrifugation, in: J. Walker (Ed.), Princ. Tech. Biochem. Mol. Biol., Cambridge University Press, Cambridge, 2005: pp. 76–80. [357] International Organization for Standardization, ISO-13322-1:2014 – “Particle size analysis – Image analysis methods. Part 1: Static image analysis methods.,” (2014). [358] J.F. Archard, W. Hirst, The Wear of Metals under Unlubricated Conditions, Proc. R. Soc. A Math. Phys. Eng. Sci. 236 (1956) 397–410. doi:10.1098/rspa.1956.0144. [359] F. Meder, T. Daberkow, L. Treccani, M. Wilhelm, M. Schowalter, A. Rosenauer, L. Mädler, K. Rezwan, Protein adsorption on colloidal alumina particles functionalized with amino, carboxyl, sulfonate and phosphate groups, Acta Biomater. 8 (2012) 1221–1229. doi:10.1016/j.actbio.2011.09.014. [360] C. Brown, S. Williams, J.L. Tipper, J. Fisher, E. Ingham, Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation, J Mater Sci Mater Med. 18 (2007) 819–827. doi:10.1007/s10856-006-0015-z. [361] I. Catelas, J.D. Bobyn, J.B. Medley, J.J. Krygier, D.J. Zukor, O.L. Huk, Size, shape, and composition of wear particles from metal-metal hip simulator testing: Effects of alloy and number of loading cycles, J. Biomed. Mater. Res. 67A (2003) 312–327. doi:10.1002/jbm.a.10088. [362] R. Büscher, G. Täger, W. Dudzinski, B. Gleising, M.A. Wimmer, A. Fischer, Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation, J. Biomed. Mater. Res. Part B Appl. Biomater. 72B (2005) 206–214. doi:10.1002/jbm.b.30132. [363] I. Catelas, J.B. Medley, P.A. Campbell, O.L. Huk, J.D. Bobyn, Comparison ofin vitro within vivo characteristics of wear particles from metal-metal hip implants, J. Biomed. Mater. Res. 70B (2004) 167–178. doi:10.1002/jbm.b.20036. [364] Z. Xia, Y.-M. Kwon, S. Mehmood, C. Downing, K. Jurkschat, D.W. Murray, Characterization of metal-wear nanoparticles in pseudotumor following metal-on-metal hip resurfacing, 2011. doi:10.1016/j.nano.2011.08.002. [365] J.G. Bowsher, A. Hussain, J. Nevelos, Williams, J.C. Shelton, LARGE HEAD DIAMETERS HAVE THE POTENTIAL TO REDUCE ION RELEASE IN METAL-ON-METAL HIP WEAR SIMULATIONS, (n.d.). http://www.ors.org/Transactions/51/1626.pdf (accessed April 29, 2017). [366] M. Boerma, G.R. Burton, J. Wang, L.M. Fink, R.E. McGehee, M. Hauer-Jensen, Comparative expression profiling in primary and immortalized endothelial cells: changes in gene expression in response to hydroxy methylglutaryl-coenzyme A reductase inhibition, Blood Coagul. Fibrinolysis. 17 (2006) 173–180. doi:10.1097/01.mbc.0000220237.99843.a1. [367] E. Lidington, D. Moyes, A. McCormack, M. Rose, A comparison of primary endothelial cells and endothelial cell lines for studies of immune interactions, Transpl. Immunol. 7 (1999) 239–246. doi:10.1016/S0966-3274(99)80008-2. [368] C. Pan, C. Kumar, S. Bohl, U. Klingmueller, M. Mann, Comparative Proteomic Phenotyping of Cell Lines and Primary Cells to Assess Preservation of Cell Type-specific Functions, Mol. Cell. Proteomics. 8 (2009) 443–450. doi:10.1074/mcp.M800258-MCP200. [369] L. Fairbairn, R. Kapetanovic, D.P. Sester, D.A. Hume, The mononuclear phagocyte system of the pig as a model for understanding human innate immunity and disease., J. Leukoc. Biol. 89 (2011) 855–71. doi:10.1189/jlb.1110607. [370] M.A. Germain, A. Hatton, S. Williams, J.B. Matthews, M.H. Stone, J. Fisher, E. Ingham, Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro, Biomaterials. 24 (2003) 469–479. [371] B. Scharf, C.C. Clement, V. Zolla, G. Perino, B. Yan, S.G. Elci, E. Purdue, S. Goldring, F. Macaluso, N. Cobelli, R.W. Vachet, L. Santambrogio, Molecular analysis of chromium and cobalt-related toxicity, Sci. Rep. 4 (2015) 5729. doi:10.1038/srep05729. [372] D. Beyersmann, A. Hartwig, Carcinogenic metal compounds: recent insight into molecular and cellular mechanisms, Arch. Toxicol. 82 (2008) 493–512. doi:10.1007/s00204-008-0313-y. [373] D.G. Barceloux, Cobalt., J. Toxicol. Clin. Toxicol. 37 (1999) 201–6. http://www.ncbi.nlm.nih.gov/pubmed/10382556 (accessed May 1, 2017). [374] A.J. Hart, S.A. Sabah, A.S. Bandi, P. Maggiore, P. Tarassoli, B. Sampson, J. A. Skinner, Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement, Bone Joint J. 93–B (2011) 1308–1313. doi:10.1302/0301-620X.93B10.26249. [375] K. De Smet, R. De Haan, A. Calistri, P. Campbell, E. Ebramzadeh, C. Pattyn, H. Gill, Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing, J. Bone Jt. Surgery-American Vol. 90 (2008) 202–208. doi:10.2106/JBJS.H.00672. [376] J. Daniel, H. Ziaee, C. Pradhan, D.J.W. McMinn, Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings, J. Bone Jt. Surg. - Br. Vol. 91–B (2009) 176–179. doi:10.1302/0301-620X.91B2.21654. [377] E. Dunstan, A.P. Sanghrajka, S. Tilley, P. Unwin, G. Blunn, S.R. Cannon, T.W.R. Briggs, Metal ion levels after metal-on-metal proximal femoral replacements: A 30-YEAR FOLLOW-UP, J. Bone Jt. Surg. - Br. Vol. 87–B (2005) 628–631. doi:10.1302/0301-620X.87B5.15384. [378] A.W. Schaffer, A. Pilger, C. Engelhardt, K. Zweymueller, H.W. Ruediger, Increased blood cobalt and chromium after total hip replacement., J. Toxicol. Clin. Toxicol. 37 (1999) 839–44. http://www.ncbi.nlm.nih.gov/pubmed/10630267 (accessed May 1, 2017). [379] O. Posada, R. Tate, R.M. Meek, M. Grant, In Vitro Analyses of the Toxicity, Immunological, and Gene Expression Effects of Cobalt-Chromium Alloy Wear Debris and Co Ions Derived from Metal-on-Metal Hip Implants, Lubricants. 3 (2015) 539–568. doi:10.3390/lubricants3030539. [380] B. Cappi, S. Neuss, J. Salber, R. Telle, R. Knuchel, H. Fischer, Cytocompatibility of high strength non-oxide ceramics, J Biomed Mater Res A. 93 (2010) 67–76. doi:10.1002/jbm.a.32527. [381] A. Neumann, T. Reske, M. Held, K. Jahnke, C. Ragoß, H.R. Maier, Comparative investigation of the biocompatibility of various silicon nitride ceramic qualities in vitro, J. Mater. Sci. Mater. Med. 15 (2004) 1135–1140. doi:10.1023/B:JMSM.0000046396.14073.92. [382] G. Kotzar, M. Freas, P. Abel, A. Fleischman, S. Roy, C. Zorman, J.M. Moran, J. Melzak, Evaluation of MEMS materials of construction for implantable medical devices, Biomaterials. 23 (2002) 2737–2750. doi:http://dx.doi.org/10.1016/S0142-9612(02)00007-8. [383] R. Kue, A. Sohrabi, D. Nagle, C. Frondoza, D. Hungerford, Enhanced proliferation and osteocalcin production by human osteoblast-like MG63 cells on silicon nitride ceramic discs, Biomaterials. 20 (1999) 1195–1201. doi:http://dx.doi.org/10.1016/S0142-9612(99)00007-1. [384] C.C. Guedes e Silva, O.Z. Higa, J.C. Bressiani, Cytotoxic evaluation of silicon nitride-based ceramics, Mater. Sci. Eng. C. 24 (2004) 643–646. doi:http://dx.doi.org/10.1016/j.msec.2004.08.007. [385] A. Neumann, M. Kramps, C. Ragoß, H.R. Maier, K. Jahnke, Histological and microradiographic appearances of Silicon Nitride and Aluminum Oxide in a rabbit femur implantation model*, Materwiss. Werksttech. 35 (2004) 569–573. doi:10.1002/mawe.200400778. [386] C.R. Howlett, E. McCartney, W. Ching, The effect of silicon nitride ceramic on rabbit skeletal cells and tissue. An in vitro and in vivo investigation, Clin Orthop Relat Res. (1989) 293–304. [387] T.J. Webster, A.A. Patel, M.N. Rahaman, B. Sonny Bal, Anti-infective and osteointegration properties of silicon nitride, poly(ether ether ketone), and titanium implants, Acta Biomater. 8 (2012) 4447–4454. doi:10.1016/j.actbio.2012.07.038. [388] S. Yang, X. Wu, Y. Hu, J. Li, G. Liu, W. Xu, C. Yang, S. Ye, Early and intermediate follow-up results after treatment of degenerative disc disease with the Bryan cervical disc prosthesis: single- and multiple-level, Spine (Phila Pa 1976). 33 (2008) E371-7. doi:10.1097/BRS.0b013e31817343a6. [389] H.L. Karlsson, J. Gustafsson, P. Cronholm, L. Möller, Size-dependent toxicity of metal oxide particles—A comparison between nano- and micrometer size, Toxicol. Lett. 188 (2009) 112–118. doi:10.1016/j.toxlet.2009.03.014. [390] T.T. Liao, Q.Y. Deng, S.S. Li, X. Li, L. Ji, Q. Wang, Y.X. Leng, N. Huang, Evaluation of the Size-Dependent Cytotoxicity of DLC (Diamondlike Carbon) Wear Debris in Arthroplasty Applications, ACS Biomater. Sci. Eng. 3 (2017) 530–539. doi:10.1021/acsbiomaterials.6b00618. [391] I. Papageorgiou, C. Brown, R. Schins, S. Singh, R. Newson, S. Davis, J. Fisher, E. Ingham, C.P. Case, The effect of nano- and micron-sized particles of cobalt-chromium alloy on human fibroblasts in vitro, Biomaterials. 28 (2007) 2946–2958. doi:10.1016/j.biomaterials.2007.02.034. [392] Y.-M. Kwon, Z. Xia, S. Glyn-Jones, D. Beard, H.S. Gill, D.W. Murray, Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro, Biomed. Mater. 4 (2009) 25018. doi:10.1088/1748-6041/4/2/025018. [393] R. Liu, C. Kurihara, H. Tsai, P.J. Silvestri, M.I. Bennett, P.F. Pasquina, S.P. Cohen, Classification and Treatment of Chronic Neck Pain, Reg. Anesth. Pain Med. 42 (2017) 52–61. doi:10.1097/AAP.0000000000000505. [394] M.F. Shriver, D.J. Lewis, V.R. Kshettry, B.P. Rosenbaum, E.C. Benzel, T.E. Mroz, Pseudoarthrosis rates in anterior cervical discectomy and fusion: A meta-analysis, Spine J. 15 (2015). doi:10.1016/j.spinee.2015.05.010. [395] M.F. Shriver, D. Lubelski, A.M. Sharma, M.P. Steinmetz, E.C. Benzel, T.E. Mroz, Adjacent segment degeneration and disease following cervical arthroplasty: a systematic review and meta-analysis, Spine J. 16 (2016) 168–181. doi:10.1016/j.spinee.2015.10.032. [396] R. Assaker, K. Ritter-Lang, D. Vardon, S. Litrico, S. Fuentes, M. Putzier, J. Franke, P. Jarzem, P. Guigui, G. Nakach, J.-C. Le Huec, Maverick total disc replacement in a real-world patient population: a prospective, multicentre, observational study, Eur. Spine J. 24 (2015) 2047–2055. doi:10.1007/s00586-015-3918-x. [397] M.F. Gornet, J.K. Burkus, R.F. Dryer, J.H. Peloza, Lumbar Disc Arthroplasty With MAVERICK Disc Versus Stand-Alone Interbody Fusion, Spine (Phila. Pa. 1976). 36 (2011) E1600–E1611. doi:10.1097/BRS.0b013e318217668f. [398] R.D. Guyer, K. Pettine, J.S. Roh, T.A. Dimmig, D. Coric, P.C. McAfee, D.D. Ohnmeiss, Comparison of 2 Lumbar Total Disc Replacements, Spine (Phila. Pa. 1976). 39 (2014) 925–931. doi:10.1097/BRS.0000000000000319. [399] N. Plais, X. Thevenot, A. Cogniet, J. Rigal, J.C. Le Huec, Maverick total disc arthroplasty performs well at 10 years follow-up: a prospective study with HRQL and balance analysis, Eur. Spine J. (2017). doi:10.1007/s00586-017-5065-z. [400] S. Green, Chapter 3 - Compounds and Composite Materials A2 - Kurtz, Steven M, in: PEEK Biomater. Handb., William Andrew Publishing, Oxford, 2012: pp. 23–48. doi:http://dx.doi.org/10.1016/B978-1-4377-4463-7.10003-X. [401] A. Zeh, M. Planert, G. Siegert, P. Lattke, A. Held, W. Hein, Release of Cobalt and Chromium Ions Into the Serum Following Implantation of the Metal-on-Metal Maverick-Type Artificial Lumbar Disc (Medtronic Sofamor Danek), Spine (Phila. Pa. 1976). 32 (2007) 348–352. doi:10.1097/01.brs.0000253599.89694.c0. [402] L.A.G. Marshman, T. Friesem, Y.R. Rampersaud, J.-C. Le Huec, M. Krishna, Subsidence and malplacement with the Oblique Maverick Lumbar Disc Arthroplasty: technical note, Spine J. 8 (2008) 650–655. doi:10.1016/j.spinee.2007.03.010. [403] R. Vanos, L.L. Lildhar, E.A. Lehoux, P.E. Beaulé, I. Catelas, In vitro macrophage response to nanometer-size chromium oxide particles, J. Biomed. Mater. Res. - Part B Appl. Biomater. 102 (2014). doi:10.1002/jbm.b.32991. [404] M. Kraft, Wear Performance of a Peek-on-Peek Bearing under Cervical Loading Conditions and at Different Test Frequencies, Glob. Spine J. 2 (2012) s-0032-1319995-s-0032-1319995. doi:10.1055/s-0032-1319995. [405] S. Williams, J.L. Tipper, E. Ingham, M.H. Stone, J. Fisher, In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 217 (2003) 155–163. doi:10.1243/095441103765212659. [406] International Organization for Standardization, BS ISO-18192-3:2017 - Implants for surgery - Wear of total intervertebral spinal disc prostheses - Part 3: Impingement-wear testing and corresponding environmental conditions for test of lumbar prostheses under adverse kinematic conditions, (2017) 21. [407] S. Wohlfart, S. Gelperina, J. Kreuter, Transport of drugs across the blood–brain barrier by nanoparticles, J. Control. Release. 161 (2012) 264–273. doi:10.1016/j.jconrel.2011.08.017. [408] C. Saraiva, C. Praça, R. Ferreira, T. Santos, L. Ferreira, L. Bernardino, Nanoparticle-mediated brain drug delivery: Overcoming blood–brain barrier to treat neurodegenerative diseases, J. Control. Release. 235 (2016) 34–47. doi:10.1016/j.jconrel.2016.05.044. [409] P.R. Lockman, R.J. Mumper, M.A. Khan, D.D. Allen, Nanoparticle Technology for Drug Delivery Across the Blood-Brain Barrier, Drug Dev. Ind. Pharm. 28 (2002) 1–13. doi:10.1081/DDC-120001481."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.736477"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/19486/1/KM_Pasko_Thesis_2017_Final.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Surgical interventions for the treatment of chronic neck pain, which affects 330 million people globally, include fusion and cervical total disc replacement (CTDR). Most of the currently clinically available CTDRs designs include a metal-on-polymer (MoP) bearing. Numerous studies suggest that MoP CTDRs are associated with issues similar to those affecting other MoP joint replacement devices, including excessive wear and wear particle-related inflammation and osteolysis. The aim of this study was to investigate the biotribology of a novel metal-on-metal (MoM) design of cervical total disc replacement device in its pristine form and coated with chromium nitride or silicon nitride, in order to understand the influence of loading conditions upon the tribological performance of the implant, and to investigate biological effects of the wear debris produced by the implants. To achieve this, a series of studies were carried out. Chromium nitride and silicon nitride coatings have been characterised for their mechanical properties, chemical composition and surface finish. Whilst some of the experiments showed minor differences between the mechanical properties and adhesion of the coatings, there was no indication of significant differences between the chromium nitride and silicon nitride coated samples. Functional testing in the six-station spine wear simulator showed that MoM CTDRs produced wear volumes significantly lower than those of the commercially available MoP devices. The wear volumes were reduced further by three-fold, following testing under altered ISO-18192-1:2011 kinematics, whereby, reduced ranges of motions were applied. Whilst the silicon nitride coated CTDRs failed catastrophically early in the test, chromium nitride coated CTDRs produced an eight-fold reduction in wear volumes, when compared to the pristine devices tested under the same conditions. Investigation of potential biological effects of the particles generated in wear testing showed that that high concentrations (5-50µm3 per cell) of CoCrMo particles resulted in significant reduction of cell viability of the L929 fibroblast cells, but not the dural fibroblasts, which were used in this study. No ceramic coating particles, at any concentrations, caused significant reduction of cell viability. In summary, results presented in this thesis showed that whilst the MoM CTDR device exhibited significantly lower wear rates than those of the commercially available MoP devices, the cytotoxic wear particles could potentially lead to adverse biological reactions, particularly in patients with metal hypersensitivity, and lead to devastating consequences similar to those of failed MoM THRs. Currently, the consequences of similar failure, leading to metalosis or pseudotumour formation in the vicinity of the spinal cord are unknown. During the investigation of the ceramic coatings, it was also found that chromium nitride ceramic coating could not only lower wear rates further, but it also has the potential to reduce the cytotoxic potential of the wear particles."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Ceramic coatings for Cervical Total Disc Replacement"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tipper, Joanne L.","Hall, Richard M.","Neville, Anne"],"dc:contributor.sponsor":["EPSRC"],"dc:creator":["Pasko, Kinga Marta"],"dc:date":["2017-08"],"dc:date.issued":["2017-08"],"dc:description.abstract":["Surgical interventions for the treatment of chronic neck pain, which affects 330 million people globally, include fusion and cervical total disc replacement (CTDR). Most of the currently clinically available CTDRs designs include a metal-on-polymer (MoP) bearing. Numerous studies suggest that MoP CTDRs are associated with issues similar to those affecting other MoP joint replacement devices, including excessive wear and wear particle-related inflammation and osteolysis. The aim of this study was to investigate the biotribology of a novel metal-on-metal (MoM) design of cervical total disc replacement device in its pristine form and coated with chromium nitride or silicon nitride, in order to understand the influence of loading conditions upon the tribological performance of the implant, and to investigate biological effects of the wear debris produced by the implants. To achieve this, a series of studies were carried out. Chromium nitride and silicon nitride coatings have been characterised for their mechanical properties, chemical composition and surface finish. Whilst some of the experiments showed minor differences between the mechanical properties and adhesion of the coatings, there was no indication of significant differences between the chromium nitride and silicon nitride coated samples. Functional testing in the six-station spine wear simulator showed that MoM CTDRs produced wear volumes significantly lower than those of the commercially available MoP devices. The wear volumes were reduced further by three-fold, following testing under altered ISO-18192-1:2011 kinematics, whereby, reduced ranges of motions were applied. Whilst the silicon nitride coated CTDRs failed catastrophically early in the test, chromium nitride coated CTDRs produced an eight-fold reduction in wear volumes, when compared to the pristine devices tested under the same conditions. Investigation of potential biological effects of the particles generated in wear testing showed that that high concentrations (5-50µm3 per cell) of CoCrMo particles resulted in significant reduction of cell viability of the L929 fibroblast cells, but not the dural fibroblasts, which were used in this study. No ceramic coating particles, at any concentrations, caused significant reduction of cell viability. In summary, results presented in this thesis showed that whilst the MoM CTDR device exhibited significantly lower wear rates than those of the commercially available MoP devices, the cytotoxic wear particles could potentially lead to adverse biological reactions, particularly in patients with metal hypersensitivity, and lead to devastating consequences similar to those of failed MoM THRs. Currently, the consequences of similar failure, leading to metalosis or pseudotumour formation in the vicinity of the spinal cord are unknown. During the investigation of the ceramic coatings, it was also found that chromium nitride ceramic coating could not only lower wear rates further, but it also has the potential to reduce the cytotoxic potential of the wear particles."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.736477"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/19486/1/KM_Pasko_Thesis_2017_Final.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/19486/"],"dc:relation.references":["[1] R. Fejer, K.O. Kyvik, J. Hartvigsen, The prevalence of neck pain in the world population: a systematic critical review of the literature, Eur. Spine J. 15 (2006) 834–848. doi:DOI 10.1007/s00586-004-0864-4. [2] T. Vos, A.D. Flaxman, M. Naghavi, M.A. AlMazroa, Z.A. Memish, Years lived with disability (YLDs) for 1160 sequelae of 289 diseases and injuries 1990-2010: a systematic analysis for the Global Burden of Disease Study 2010 (vol 380, pg 2163, 2012), Lancet. 381 (2013) 628. [3] D.G. Hoy, M. Protani, R. De, R. Buchbinder, The epidemiology of neck pain, Best Pract. Res. Clin. Rheumatol. 24 (2010) 783–792. doi:DOI 10.1016/j.berh.2011.01.019. [4] L.J. Carroll, S. Hogg-Johnson, G. van der Velde, S. Haldeman, L.W. Holm, E.J. Carragee, E.L. Hurwitz, P. Cote, M. Nordin, P.M. Peloso, J. Guzman, J.D. Cassidy, Course and prognostic factors for neck pain in the general population - Results of the bone and joint decade 2000-2010 task force on neck pain and its associated disorders, J Manip. Physiol Ther. 32 (2008) S75–S82. doi:DOI 10.1016/j.jmpt.2008.11.013. [5] J. Hill, M. Lewis, A.C. Papageorgiou, K. Dziedzic, P. Croft, Predicting persistent neck pain - A 1-year follow-up of a population cohort, Spine (Phila Pa 1976). 29 (2004) 1648–1654. doi:Doi 10.1097/01.Brs.0000132307.06321.3c. [6] P. Cote, G. van der Velde, J.D. Cassidy, L.J. Carroll, S. Hogg-Johnson, L.W. Holm, E.J. Carragee, S. Haldeman, M. Nordin, E.L. Hurwitz, J. Guzman, P.M. Peloso, The burden and determinants of neck pain in workers - Results of the bone and joint decade 2000-2010 task force on neck pain and its associated disorders, J Manip. Physiol Ther. 32 (2008) S60–S74. doi:DOI 10.1016/j.jmpt.2008.11.012. [7] S.D.M. Bot, J.M. van der Waal, C.B. Terwee, D.A.W.M. van der Windt, F.G. Schellevis, L.M. Bouter, J. Dekker, Incidence and prevalence of complaints of the neck and upper extremity in general practice, Ann Rheum Dis. 64 (2005) 118–123. doi:DOI 10.1136/ard.2003.019349. [8] P. Cote, J.D. Cassidy, L.J. Carroll, V. Kristman, The annual incidence and course of neck pain in the general population: a population-based cohort study, Pain. 112 (2004) 267–273. doi:DOI 10.1016/j.pain.2004.09.004. [9] S.D.M. Bot, J.M. van der Waal, C.B. Terwee, D.A.W.M. van der Windt, R.J.P.M. Scholten, L.M. Bouter, J. Dekker, Predictors of outcome in neck and shoulder symptoms - A cohort study in general practice, Spine (Phila Pa 1976). 30 (2005) E459–E470. doi:DOI 10.1097/01.brs.0000174279.44855.02. [10] A. Berglund, L. Alfredsson, I. Jensen, J.D. Cassidy, A. Nygren, The association between exposure to a rear-end collision and future health complaints, J Clin Epidemiol. 54 (2001) 851–856. doi:Doi 10.1016/S0895-4356(00)00369-3. [11] E.L. Hurwitz, M.S. Goldstein, H. Morgenstern, L.M. Chiang, The impact of psychosocial factors on neck pain and disability outcomes among primary care patients: Results from the UCLA Neck Pain Study, Disabil Rehabil. 28 (2006) 1319–1329. doi:Doi 10.1080/09638280600641509. [12] J.L. Kelsey, P.B. Githens, S.D. Walter, W.O. Southwick, U. Weil, T.R. Holford, A.M. Ostfeld, J.A. Calogero, T. Oconnor, A.A. White, An Epidemiological-Study of Acute Prolapsed Cervical Intervertebral-Disk, J. Bone Jt. Surgery-American Vol. 66A (1984) 907–914. [13] K.T. Palmer, K. Walker-Bone, M.J. Griffin, H. Syddall, B. Pannett, D. Coggon, C. Cooper, Prevalence and occupational associations of neck pain in the British population, Scand J Work Env. Heal. 27 (2001) 49–56. http://www.ncbi.nlm.nih.gov/pubmed/11266146. [14] J. Guzman, E.L. Hurwitz, L.J. Carroll, S. Haldeman, P. Cote, E.J. Carragee, P.M. Peloso, G. van der Velde, L.W. Holm, S. Hogg-Johnson, M. Nordin, J.D. Cassidy, A new conceptual model of neck pain - Linking onset, course, and care: The bone and joint decade 2000-2010 task force on neck pain and its associated disorders, Spine (Phila Pa 1976). 33 (2008) S14–S23. [15] L. Manchikanti, V. Singh, S. Datta, S.P. Cohen, J.A. Hirsch, Comprehensive Review of Epidemiology, Scope, and Impact of Spinal Pain, Pain Physician. 12 (2009) E35–E70. [16] B.I. Martin, R.A. Deyo, S.K. Mirza, J.A. Turner, B.A. Comstock, W. Hollingworth, S.D. Sullivan, Expenditures and health status among adults with back and neck problems, JAMA. 299 (2008) 656–664. doi:10.1001/jama.299.6.656. [17] S. Haldeman, L.J. Carroll, J.D. Cassidy, The empowerment of people with neck pain: Introduction - The bone and joint decade 2000-2010 task force on neck pain and its associated disorders, Spine (Phila Pa 1976). 33 (2008) S8–S13. [18] AAOS, Burden of Musculoskeletal Diseases in the United States: Prevalence, Societal and Economic Cost, American Academy of Orthopaedic Surgeons, 2008. http://books.google.co.uk/books?id=Mp0TAQAAMAAJ. [19] A. Wright, T.G. Mayer, R.J. Gatchel, Outcomes of disabling cervical spine disorders in compensation injuries - A prospective comparison to tertiary rehabilitation response for chronic lumbar spinal disorders, Spine (Phila Pa 1976). 24 (1999) 178–183. doi:Doi 10.1097/00007632-199901150-00020. [20] W.L. Eckalbar, R.E. Fisher, A. Rawls, K. Kusumi, Scoliosis and segmentation defects of the vertebrae, Wiley Interdiscip. Rev. Dev. Biol. 1 (2012) 401–423. doi:10.1002/wdev.34. [21] M. Nordin, V.H. Frankel, D. Leger, Basic biomechanics of the musculoskeletal system, 4th ed., Lippincott Williams & Wilkins, Baltimore, MD ; London, 2012. [22] O.A. Onan, M.H. Heggeness, J.A. Hipp, A motion analysis of the cervical facet joint, Spine (Phila Pa 1976). 23 (1998) 430–439. [23] C.R. Clark, T.B. Ducker, Cervical Spine Research Society. Editorial Committee., The cervical spine, 3rd ed., Lippincott-Raven, Philadelphia, 1998. [24] J.D. Bartleson, H.G. Deen, Spine disorders : medical and surgical management, Cambridge University Press, Cambridge, 2009. [25] V.K. Goel, A. Faizan, V. Palepu, S. Bhattacharya, Parameters that effect spine biomechanics following cervical disc replacement, Eur. Spine J. 21 Suppl 5 (2012) S688-99. doi:10.1007/s00586-011-1816-4. [26] G.V.K. Faizan A Krishna M, Friesem T, Effects of removal of uncinate process in the cervical disc replacement model: a finite element study, in: 53rd Annu. Meet. Orthop. Res. Soc., San Diego, CA, 2007. [27] J.T. Snyder, M.N. Tzermiadianos, A.J. Ghanayem, L.I. Voronov, A. Rinella, A. Dooris, G. Carandang, S.M. Renner, R.M. Havey, A.G. Patwardhan, Effect of uncovertebral joint excision on the motion response of the cervical spine after total disc replacement, Spine (Phila Pa 1976). 32 (2007) 2965–2969. doi:10.1097/BRS.0b013e31815cd482. [28] N. Bogduk, S. Mercer, Biomechanics of the cervical spine. I: Normal kinematics, Clin Biomech (Bristol, Avon). 15 (2000) 633–648. http://www.ncbi.nlm.nih.gov/pubmed/10946096. [29] M. Muller-Gerbl, S. Weisser, U. Linsenmeier, The distribution of mineral density in the cervical vertebral endplates, Eur. Spine J. 17 (2008) 432–438. doi:10.1007/s00586-008-0601-5. [30] E.C. Benzel, The cervical spine, 5th ed., Lippincott Williams & Wilkins, Philadelphia, PA, USA, 2012. [31] P.C. Ivancic, M.P. Coe, A.B. Ndu, Y. Tominaga, E.J. Carlson, W. Rubin, F.H. Dipl-Ing, M.M. Panjabi, Dynamic mechanical properties of intact human cervical spine ligaments, Spine J. 7 (2007) 659–665. doi:http://dx.doi.org/10.1016/j.spinee.2006.10.014. [32] H.C. Elliott, Cross-sectional diameters and areas of the human spinal cord, Anat Rec. 93 (1945) 287–293. http://www.ncbi.nlm.nih.gov/pubmed/21008200. [33] A.A. White, M.M. Panjabi, Clinical biomechanics of the spine, 2nd ed., Lippincott, Philadelphia, 1990. [34] L.T. Twomey, J.R. Taylor, Age-Changes in Lumbar Vertebrae and Intervertebral Disks, Clin. Orthop. Relat. Res. (1987) 97–104. [35] H.S. An, P.A. Anderson, V.M. Haughton, J.C. Iatridis, J.D. Kang, J.C. Lotz, R.N. Natarajan, T.R. Oegema Jr., P. Roughley, L.A. Setton, J.P. Urban, T. Videman, G.B. Andersson, J.N. Weinstein, Introduction: disc degeneration: summary, Spine (Phila Pa 1976). 29 (2004) 2677–2678. http://www.ncbi.nlm.nih.gov/pubmed/15564916. [36] J. Yu, P.C. Winlove, S. Roberts, J.P. Urban, Elastic fibre organization in the intervertebral discs of the bovine tail, J Anat. 201 (2002) 465–475. http://www.ncbi.nlm.nih.gov/pubmed/12489758. [37] J.P.G. Urban, A. Maroudas, M.T. Bayliss, J. Dillon, Swelling Pressures of Proteoglycans at the Concentrations Found in Cartilaginous Tissues, Biorheology. 16 (1979) 447–464. [38] F. Galbusera, M. van Rijsbergen, K. Ito, J.M. Huyghe, M. Brayda-Bruno, H.-J. Wilke, Ageing and degenerative changes of the intervertebral disc and their impact on spinal flexibility, Eur. Spine J. 23 (2014) 324–332. doi:10.1007/s00586-014-3203-4. [39] N.A. Ebraheim, A. Hassan, M. Lee, R. Xu, Functional anatomy of the lumbar spine, Semin. Pain Med. 2 (2004) 131–137. doi:http://dx.doi.org/10.1016/j.spmd.2004.08.004. [40] J. Schroder, M. Herbort, P. Rustemeyer, V. Vieth, H. Wassmann, Mechanical response of cervical vertebral endplates to axial loading, Zentralbl Neurochir. 67 (2006) 188–192. doi:10.1055/s-2006-942279. [41] T.G. Lowe, S. Hashim, L.A. Wilson, M.F. O’Brien, D.A. Smith, M.J. Diekmann, J. Trommeter, A biomechanical study of regional endplate strength and cage morphology as it relates to structural interbody support, Spine (Phila Pa 1976). 29 (2004) 2389–2394. [42] R.S. Ochia, A.F. Tencer, R.P. Ching, Effect of loading rate on endplate and vertebral body strength in human lumbar vertebrae, J Biomech. 36 (2003) 1875–1881. doi:http://dx.doi.org/10.1016/S0021-9290(03)00211-2. [43] S. Roberts, S.M. Eisenstein, J. Menage, E.H. Evans, I.K. Ashton, Mechanoreceptors in intervertebral discs - Morphology, distribution, and neuropeptides, Spine (Phila Pa 1976). 20 (1995) 2645–2651. doi:Doi 10.1097/00007632-199512150-00005. [44] S.P. Moroney, A.B. Schultz, J.A. Miller, Analysis and measurement of neck loads, J Orthop Res. 6 (1988) 713–720. doi:10.1002/jor.1100060514. [45] D.A. Winter, Anthropometry, in: Biomech. Mot. Control Hum. Mov., John Wiley & Sons, Inc., 2009: pp. 82–106. doi:10.1002/9780470549148.ch4. [46] M.M. Panjabi, J. Cholewicki, K. Nibu, J. Grauer, L.B. Babat, J. Dvorak, Critical load of the human cervical spine: an in vitro experimental study, Clin Biomech (Bristol, Avon). 13 (1998) 11–17. http://www.ncbi.nlm.nih.gov/pubmed/11415766. [47] J.A. Buckwalter, Aging and degeneration of the human intervertebral disc, Spine (Phila Pa 1976). 20 (1995) 1307–1314. http://www.ncbi.nlm.nih.gov/pubmed/7660243. [48] C. Lansade, S. Laporte, P. Thoreux, M.A. Rousseau, W. Skalli, F. Lavaste, Three-dimensional analysis of the cervical spine kinematics: effect of age and gender in healthy subjects, Spine (Phila Pa 1976). 34 (2009) 2900–2906. doi:10.1097/BRS.0b013e3181b4f667. [49] D.. H. Cobian B.; Daehn, N.; Anderson, P.A, Comparison of Daily Motion of the Cervical and Lumbar Spine to ASTM F2423-11 and ISO 18192-1.2011 Standard Testing, Static Dyn. Spinal Implant. Are We Eval. Them Appropriately? 1535 (2012) 14. doi:10.1520/JAI103522. [50] S.E. Bennett, R.J. Schenk, E.D. Simmons, Active range of motion utilized in the cervical spine to perform daily functional tasks, J Spinal Disord Tech. 15 (2002) 307–311. [51] E. Lysell, Motion in the cervical spine. An experimental study on autopsy specimens, Acta Orthop Scand. (1969) Suppl 123:1+. http://www.ncbi.nlm.nih.gov/pubmed/4907116. [52] M. Panjabi, J. Dvorak, J. Crisco 3rd, T. Oda, A. Hilibrand, D. Grob, Flexion, extension, and lateral bending of the upper cervical spine in response to alar ligament transections, J Spinal Disord. 4 (1991) 157–167. http://www.ncbi.nlm.nih.gov/pubmed/1806080. [53] M.P. Steinmetz, T.E. Mroz, E.C. Benzel, Craniovertebral junction: biomechanical considerations, Neurosurgery. 66 (2010) 7–12. doi:10.1227/01.NEU.0000366109.85796.42. [54] V.K. Goel, C.R. Clark, D. McGowan, S. Goyal, An in-vitro study of the kinematics of the normal, injured and stabilized cervical spine, J Biomech. 17 (1984) 363–376. http://www.ncbi.nlm.nih.gov/pubmed/6736071. [55] S.P. Cohen, Epidemiology, Diagnosis, and Treatment of Neck Pain, Mayo Clin. Proc. 90 (2015) 284–299. doi:10.1016/j.mayocp.2014.09.008. [56] K. Fujiwara, M. Fujimoto, H. Owaki, J. Kono, T. Nakase, K. Yonenobu, T. Ochi, Cervical lesions related to the systemic progression in rheumatoid arthritis, Spine (Phila Pa 1976). 23 (1998) 2052–2056. http://www.ncbi.nlm.nih.gov/pubmed/9794048. [57] W.O. Spitzer, M.L. Skovron, L.R. Salmi, J.D. Cassidy, J. Duranceau, S. Suissa, E. Zeiss, M.L. Skooron, L.R. Salmi, J.D. Cassidy, J. Duranceau, S. Suissa, E. Zeiss, Scientific Monograph of the Quebec Task-Force on Whiplash-Associated Disorders - Redefining Whiplash and Its Management, Spine (Phila Pa 1976). 20 (1995) 2372. [58] R. Ferrari, Prevention of chronic pain after whiplash, Emerg Med J. 19 (2002) 526–530. http://www.ncbi.nlm.nih.gov/pubmed/12421777. [59] H.H. Bohlman, S.E. Emery, D.B. Goodfellow, P.K. Jones, Robinson anterior cervical discectomy and arthrodesis for cervical radiculopathy. Long-term follow-up of one hundred and twenty-two patients, J Bone Jt. Surg Am. 75 (1993) 1298–1307. http://www.ncbi.nlm.nih.gov/pubmed/8408151. [60] T. Adamson, S.S. Godil, M. Mehrlich, S. Mendenhall, A.L. Asher, M.J. McGirt, Anterior cervical discectomy and fusion in the outpatient ambulatory surgery setting compared with the inpatient hospital setting: analysis of 1000 consecutive cases, J. Neurosurg. Spine. 24 (2016) 878–884. doi:10.3171/2015.8.SPINE14284. [61] P.S. Saphier, M.S. Arginteanu, F.M. Moore, A.A. Steinberger, M.B. Camins, Stress-shielding compared with load-sharing anterior cervical plate fixation: a clinical and radiographic prospective analysis of 50 patients, J Neurosurg Spine. 6 (2007) 391–397. doi:10.3171/spi.2007.6.5.391. [62] U.K. Chang, D.H. Kim, M.C. Lee, R. Willenberg, S.H. Kim, J. Lim, Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion, J Neurosurg Spine. 7 (2007) 33–39. doi:10.3171/SPI-07/07/033. [63] M.P. Kelly, J.M. Mok, R.F. Frisch, B.K. Tay, Adjacent segment motion after anterior cervical discectomy and fusion versus Prodisc-c cervical total disk arthroplasty: analysis from a randomized, controlled trial, Spine (Phila Pa 1976). 36 (2011) 1171–1179. doi:10.1097/BRS.0b013e3181ec5c7d. [64] J. Goffin, E. Geusens, N. Vantomme, E. Quintens, Y. Waerzeggers, B. Depreitere, F. Van Calenbergh, J. van Loon, Long-term follow-up after interbody fusion of the cervical spine, J Spinal Disord Tech. 17 (2004) 79–85. http://www.ncbi.nlm.nih.gov/pubmed/15260088. [65] A.S. Hilibrand, G.D. Carlson, M.A. Palumbo, P.K. Jones, H.H. Bohlman, Radiculopathy and myelopathy at segments adjacent to the site of a previous anterior cervical arthrodesis, J. Bone Jt. Surgery-American Vol. 81A (1999) 519–528. [66] D.-H. Lee, J.H. Cho, C.J. Hwang, C.S. Lee, S.K. Cho, C. Kim, J.-K. Ha, What is the Fate of Pseudarthrosis Detected 1 Year After Anterior Cervical Discectomy and Fusion?, Spine (Phila. Pa. 1976). (2017) 1. doi:10.1097/BRS.0000000000002077. [67] B. Moatz, P.J. Tortolani, Cervical disc arthroplasty: Pros and cons, Surg Neurol Int. 3 (2012) S216-24. doi:10.4103/2152-7806.98582. [68] M. Thaler, S. Hartmann, M. Gstottner, R. Lechner, M. Gabl, C. Bach, Footprint mismatch in total cervical disc arthroplasty, Eur. Spine J. 22 (2013) 759–765. doi:10.1007/s00586-012-2594-3. [69] M. Gstoettner, D. Heider, M. Liebensteiner, C.M. Bach, Footprint mismatch in lumbar total disc arthroplasty, Eur. Spine J. 17 (2008) 1470–1475. doi:10.1007/s00586-008-0780-0. [70] B.M. Wroblewski, P.D. Siney, P.A. Fleming, The principle of low frictional torque in the Charnley total hip replacement, J Bone Jt. Surg Br. 91 (2009) 855–858. doi:10.1302/0301-620X.91B7.22027. [71] A. Shaheen, D.E. Shepherd, Lubrication regimes in lumbar total disc arthroplasty, Proc Inst Mech Eng H. 221 (2007) 621–627. http://www.ncbi.nlm.nih.gov/pubmed/17937201. [72] H. Yao, W.Y. Gu, Physical signals and solute transport in human intervertebral disc during compressive stress relaxation: 3D finite element analysis, Biorheology. 43 (2006) 323–335. http://www.ncbi.nlm.nih.gov/pubmed/16912405. [73] W. V Dowson. D, Bio-tribology, in: D. T.C (Ed.), Rheol. Lubr., Science Publishers, Barking, 1973: pp. 81–88. [74] E. Ingham, J. Fisher, Biological reactions to wear debris in total joint replacement, Proc Inst Mech Eng H. 214 (2000) 21–37. http://www.ncbi.nlm.nih.gov/pubmed/10718048. [75] D.J. Langton, T.J. Joyce, S.S. Jameson, J. Lord, M. Van Orsouw, J.P. Holland, A. V Nargol, K.A. De Smet, Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear, J Bone Jt. Surg Br. 93 (2011) 164–171. doi:10.1302/0301-620X.93B2.25099. [76] Dowson. D, Biotribology of natural and replacement joints, in: V.C. Mow (Ed.), Biomech. Diarthrodial Joints, Springer Verlag, New York, 1990: pp. 303–345. [77] A. Bennett, Higginso.Gr, Hydrodynamic Lubrication of Soft Solids, J. Mech. Eng. Sci. 12 (1970) 218-. [78] J.S. Hou, V.C. Mow, W.M. Lai, M.H. Holmes, An analysis of the squeeze-film lubrication mechanism for articular cartilage, J Biomech. 25 (1992) 247–259. http://www.ncbi.nlm.nih.gov/pubmed/1564060. [79] M. Jagatia, D. Jalali-Vahid, Z.M. Jin, Elastohydrodynamic lubrication analysis of ultra-high molecular weight polyethylene hip joint replacements under squeeze-film motion, Proc Inst Mech Eng H. 215 (2001) 141–152. [80] P.S. Walker, D. Dowson, M.D. Longfield, V. Wright, “Boosted lubrication” in synovial joints by fluid entrapment and enrichment, Ann Rheum Dis. 27 (1968) 512–520. http://www.ncbi.nlm.nih.gov/pubmed/5728097. [81] P.R. Lewis, C.W. McCutchen, Experimental evidence for weeping lubrication in mammalian joints, Nature. 184 (1959) 1285. [82] J.F. Archard, Contact and Rubbing of Flat Surfaces, J. Appl. Phys. 24 (1953) 981–988. doi:10.1063/1.1721448. [83] R.G. Bayer, Mechanical Wear Fundamentals and Testing, Revised and Expanded, Taylor & Francis, 2004. http://books.google.co.uk/books?id=Q64Kq2HlyucC. [84] H.C. Amstutz, P. Campbell, N. Kossovsky, I.C. Clarke, Mechanism and clinical significance of wear debris-induced osteolysis, Clin Orthop Relat Res. (1992) 7–18. http://www.ncbi.nlm.nih.gov/pubmed/1537177. [85] S.B. Goodman, T. Wright, 2007 AAOS/NIH osteolysis and implant wear: biological, biomedical engineering, and surgical principles. Introduction, J Am Acad Orthop Surg. 16 Suppl 1 (2008) x–xi. doi:16/suppl_1/x [pii]. [86] S.M. Kurtz, A. van Ooij, R. Ross, J. de Waal Malefijt, J. Peloza, L. Ciccarelli, M.L. Villarraga, Polyethylene wear and rim fracture in total disc arthroplasty, Spine J. 7 (2007) 12–21. doi:http://dx.doi.org/10.1016/j.spinee.2006.05.012. [87] Y. Yan, A. Neville, D. Dowson, Biotribocorrosion—an appraisal of the time dependence of wear and corrosion interactions: II. Surface analysis, J. Phys. D. Appl. Phys. 39 (2006) 3206. http://stacks.iop.org/0022-3727/39/i=15/a=S11. [88] Y. Yan, A. Neville, D. Dowson, Biotribocorrosion - an appraisal of the time dependence of wear and corrosion interactions: I. The role of corrosion, J. Phys. D. Appl. Phys. 39 (2006) 3200–3205. doi:10.1088/0022-3727/39/15/S10. [89] S.M. Kurtz, The UHMWPE Handbook: Ultra-High Molecular Weight Polyethylene in Total Joint Replacement, Elsevier Science, 2004. http://books.google.co.uk/books?id=bkuFjppEdMcC. [90] R. Narayan, Biomedical Materials, Springer Science & Business Media, New York, 2009. http://books.google.co.uk/books?id=wyFYTCus8OgC. [91] Substech.com, Abrasive wear, (2012). http://www.substech.com/dokuwiki/doku.php?id=mechanisms_of_wear. [92] B.H. Cummins, J.T. Robertson, S.S. Gill, Surgical experience with an implanted artificial cervical joint, J Neurosurg. 88 (1998) 943–948. doi:10.3171/jns.1998.88.6.0943. [93] N. Hallab, H.D. Link, P.C. McAfee, Biomaterial optimization in total disc arthroplasty, Spine (Phila Pa 1976). 28 (2003) S139-52. doi:10.1097/01.BRS.0000092214.87225.80. [94] I. GOTMAN, Characteristics of Metals Used in Implants, J. Endourol. 11 (1997) 383–389. doi:10.1089/end.1997.11.383. [95] P.F. Doorn, J.M. Mirra, P.A. Campbell, H.C. Amstutz, Tissue reaction to metal on metal total hip prostheses, Clin Orthop Relat Res. (1996) S187-205. http://www.ncbi.nlm.nih.gov/pubmed/8769334. [96] D. Bitar, J. Parvizi, Biological response to prosthetic debris., World J. Orthop. 6 (2015) 172–89. doi:10.5312/wjo.v6.i2.172. [97] J.P. Lemaire, H. Carrier, H. Sariali el, W. Skalli, F. Lavaste, Clinical and radiological outcomes with the Charite artificial disc: a 10-year minimum follow-up, J Spinal Disord Tech. 18 (2005) 353–359. http://www.ncbi.nlm.nih.gov/pubmed/16021017. [98] R.C. Huang, F.P. Girardi, F.P. Cammisa Jr., T.M. Wright, The implications of constraint in lumbar total disc replacement, J Spinal Disord Tech. 16 (2003) 412–417. http://www.ncbi.nlm.nih.gov/pubmed/12902958. [99] P. V Mummaneni, J.K. Burkus, R.W. Haid, V.C. Traynelis, T.A. Zdeblick, Clinical and radiographic analysis of cervical disc arthroplasty compared with allograft fusion: a randomized controlled clinical trial, J Neurosurg Spine. 6 (2007) 198–209. doi:10.3171/spi.2007.6.3.198. [100] J.K. Burkus, R.W. Haid, V.C. Traynelis, P. V Mummaneni, Long-term clinical and radiographic outcomes of cervical disc replacement with the Prestige disc: results from a prospective randomized controlled clinical trial, J Neurosurg Spine. 13 (2010) 308–318. doi:10.3171/2010.3.SPINE09513. [101] J.K. Burkus, V.C. Traynelis, R.W. Haid, P. V. Mummaneni, Clinical and radiographic analysis of an artificial cervical disc: 7-year follow-up from the Prestige prospective randomized controlled clinical trial, J. Neurosurg. Spine. 21 (2014) 516–528. doi:10.3171/2014.6.SPINE13996. [102] F. Porchet, N.H. Metcalf, Clinical outcomes with the Prestige II cervical disc: preliminary results from a prospective randomized clinical trial, Neurosurg Focus. 17 (2004) E6. http://www.ncbi.nlm.nih.gov/pubmed/15636562. [103] D. Murrey, M. Janssen, R. Delamarter, J. Goldstein, J. Zigler, B. Tay, B. Darden, Results of the prospective, randomized, controlled multicenter Food and Drug Administration investigational device exemption study of the ProDisc-C total disc replacement versus anterior discectomy and fusion for the treatment of 1-level symptomatic cervi, Spine J. 9 (2009) 275–286. doi:10.1016/j.spinee.2008.05.006. [104] R.B. Delamarter, D. Murrey, M.E. Janssen, J.A. Goldstein, J. Zigler, B.K.B. Tay, B. Darden Ii, Results at 24 months from the prospective, randomized, multicenter Investigational Device Exemption trial of ProDisc-C versus anterior cervical discectomy and fusion with 4-year follow-up and continued access patients, SAS J. 4 (2010) 122–128. doi:http://dx.doi.org/10.1016/j.esas.2010.09.001. [105] J.E. Zigler, R. Delamarter, D. Murrey, J. Spivak, M. Janssen, ProDisc-C and Anterior Cervical Discectomy and Fusion as Surgical Treatment for Single-Level Cervical Symptomatic Degenerative Disc Disease Five-Year Results of a Food and Drug Administration Study, Spine (Phila Pa 1976). 38 (2013) 203–209. doi:Doi 10.1097/Brs.0b013e318278eb38. [106] R.C. Sasso, P.A. Anderson, K.D. Riew, J.G. Heller, Results of cervical arthroplasty compared with anterior discectomy and fusion: four-year clinical outcomes in a prospective, randomized controlled trial, Orthopedics. 34 (2011) 889. doi:10.3928/01477447-20110922-24. [107] R.C. Sasso, J.D. Smucker, R.J. Hacker, J.G. Heller, Clinical outcomes of BRYAN cervical disc arthroplasty: a prospective, randomized, controlled, multicenter trial with 24-month follow-up, J Spinal Disord Tech. 20 (2007) 481–491. doi:10.1097/BSD.0b013e3180310534. [108] J. Marzluff, J. McConnell, C. Tomaras, W. Peppelman, I. Volcan, K. Baker, 2-Year Multicenter Follow-up in a Prospective Randomized Clinical Trial: Comparison of a Cervical Artificial Disc to an ACDF Treatment, Spine J. 10 (2010) S135–S136. doi:http://dx.doi.org/10.1016/j.spinee.2010.07.349. [109] A. Vaccaro, W. Beutler, W. Peppelman, J.M. Marzluff, J. Highsmith, A. Mugglin, G. DeMuth, M. Gudipally, K.J. Baker, Clinical Outcomes With Selectively Constrained SECURE-C Cervical Disc Arthroplasty, Spine (Phila. Pa. 1976). 38 (2013) 2227–2239. doi:10.1097/BRS.0000000000000031. [110] F.M. Phillips, J.Y.B. Lee, F.H. Geisler, A. Cappuccino, C.D. Chaput, J.G. DeVine, C. Reah, K.M. Gilder, K.M. Howell, P.C. McAfee, A Prospective, Randomized, Controlled Clinical Investigation Comparing PCM Cervical Disc Arthroplasty With Anterior Cervical Discectomy and Fusion, Spine (Phila. Pa. 1976). 38 (2013) E907–E918. doi:10.1097/BRS.0b013e318296232f. [111] F.M. Phillips, F.H. Geisler, K.M. Gilder, C. Reah, K.M. Howell, P.C. McAfee, Long-term Outcomes of the US FDA IDE Prospective, Randomized Controlled Clinical Trial Comparing PCM Cervical Disc Arthroplasty With Anterior Cervical Discectomy and Fusion, Spine (Phila. Pa. 1976). 40 (2015) 674–683. doi:10.1097/BRS.0000000000000869. [112] M. Hisey, H. Bae, R. Davis, S. Gaede, G. Hoffman, K. Kim, P. Nunley, D. Peterson, R. Rashbaum, J. Stokes, Multi-center, Prospective, Randomized, Controlled Investigational Device Exemption Clinical Trial Comparing Mobi?C Cervical Artificial Disc to Anterior Discectomy and Fusion in the Treatment of Symptomatic Degenerative Disc Disease in the Cervical Spine, Int. J. Spine Surg. 8 (2014) 7–7. doi:10.14444/1007. [113] M.S. Hisey, H.W. Bae, R.J. Davis, S. Gaede, G. Hoffman, K.D. Kim, P.D. Nunley, D. Peterson, R.F. Rashbaum, J. Stokes, D.D. Ohnmeiss, Prospective, Randomized Comparison of Cervical Total Disk Replacement Versus Anterior Cervical Fusion, J. Spinal Disord. Tech. 28 (2015) E237–E243. doi:10.1097/BSD.0000000000000185. [114] M.S. Hisey, J.E. Zigler, R. Jackson, P.D. Nunley, H.W. Bae, K.D. Kim, D.D. Ohnmeiss, Prospective, Randomized Comparison of One-level Mobi-C Cervical Total Disc Replacement vs. Anterior Cervical Discectomy and Fusion: Results at 5-year Follow-up., Int. J. Spine Surg. 10 (2016) 10. doi:10.14444/3010. [115] M.F. Gornet, J.K. Burkus, M.E. Shaffrey, P.J. Argires, H. Nian, F.E. Harrell, Cervical disc arthroplasty with PRESTIGE LP disc versus anterior cervical discectomy and fusion: a prospective, multicenter investigational device exemption study, J. Neurosurg. Spine. 23 (2015) 558–573. doi:10.3171/2015.1.SPINE14589. [116] M. Gornet, J.K. Burkus, M. Shaffrey, H. Nian, F. Harrell, Cervical Disc Arthroplasty with Prestige LP Disc Versus Anterior Cervical Discectomy and Fusion: Seven-Year Outcomes, Int. J. Spine Surg. 10 (2016) 24. doi:10.14444/3024. [117] J.G. Heller, R.C. Sasso, S.M. Papadopoulos, P.A. Anderson, R.G. Fessler, R.J. Hacker, D. Coric, J.C. Cauthen, D.K. Riew, Comparison of BRYAN Cervical Disc Arthroplasty With Anterior Cervical Decompression and Fusion, Spine (Phila. Pa. 1976). 34 (2009) 101–107. doi:10.1097/BRS.0b013e31818ee263. [118] J. Fisher, J. Bell, P.S. Barbour, J.L. Tipper, J.B. Matthews, A.A. Besong, M.H. Stone, E. Ingham, A novel method for the prediction of functional biological activity of polyethylene wear debris, Proc Inst Mech Eng H. 215 (2001) 127–132. http://www.ncbi.nlm.nih.gov/pubmed/11382071. [119] S.M. Kurtz, J.M. Toth, R. Siskey, L. Ciccarelli, D. MacDonald, J. Isaza, T. Lanman, I. Punt, M. Steinbeck, J. Goffin, A. van Ooij, The Latest Lessons Learned from Retrieval Analyses of Ultra-High Molecular Weight Polyethylene, Metal-on-Metal, and Alternative Bearing Total Disc Replacements, Semin. Spine Surg. 24 (2012) 57–70. doi:http://dx.doi.org/10.1053/j.semss.2011.11.011. [120] M.A. Wimmer, A. Fischer, R. Buscher, R. Pourzal, C. Sprecher, R. Hauert, J.J. Jacobs, Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers, J Orthop Res. 28 (2010) 436–443. doi:10.1002/jor.21020. [121] P.A. Anderson, J.P. Rouleau, J.M. Toth, K.D. Riew, A comparison of simulator-tested and -retrieved cervical disc prostheses. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2004, J Neurosurg Spine. 1 (2004) 202–210. doi:10.3171/spi.2004.1.2.0202. [122] D. Lebl, F. Cammisa, F. Girardi, T. Wright, C. Abjornson, Analysis of Wear, Surface Properties, and Fixation of Explanted Cervical Total Disc Replacements, Spine J. 11 (2011) S45. doi:http://dx.doi.org/10.1016/j.spinee.2011.08.119. [123] D.R. Lebl, F.P. Cammisa Jr., F.P. Girardi, T. Wright, C. Abjornson, The mechanical performance of cervical total disc replacements in vivo: prospective retrieval analysis of prodisc-C devices, Spine (Phila Pa 1976). 37 (2012) 2151–2160. doi:10.1097/BRS.0b013e31826b3f61. [124] L.M. Tumialan, W.M. Gluf, Progressive vertebral body osteolysis after cervical disc arthroplasty, Spine (Phila Pa 1976). 36 (2011) E973-8. doi:10.1097/BRS.0b013e3181fd863b. [125] C.J. Devin, T.G. Myers, J.D. Kang, Chronic failure of a lumbar total disc replacement with osteolysis. Report of a case with nineteen-year follow-up, J Bone Jt. Surg Am. 90 (2008) 2230–2234. doi:10.2106/JBJS.G.01712. [126] A. van Ooij, S.M. Kurtz, F. Stessels, H. Noten, L. van Rhijn, Polyethylene wear debris and long-term clinical failure of the Charite disc prosthesis: a study of 4 patients, Spine (Phila Pa 1976). 32 (2007) 223–229. doi:10.1097/01.brs.0000251370.56327.c6. [127] B.W. Cunningham, C.M. Orbegoso, A.E. Dmitriev, N.J. Hallab, J.C. Sefter, P. Asdourian, P.C. McAfee, The effect of spinal instrumentation particulate wear debris. an in vivo rabbit model and applied clinical study of retrieved instrumentation cases, Spine J. 3 (2003) 19–32. http://www.ncbi.nlm.nih.gov/pubmed/14589241. [128] R.D. Guyer, J. Shellock, B. MacLennan, D. Hanscom, R.Q. Knight, P. McCombe, J.J. Jacobs, R.M. Urban, D. Bradford, D.D. Ohnmeiss, Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases, Spine (Phila Pa 1976). 36 (2011) E492-7. doi:10.1097/BRS.0b013e31820ea9a2. [129] D.A. Cavanaugh, P.D. Nunley, E.J. Kerr 3rd, D.J. Werner, A. Jawahar, Delayed hyper-reactivity to metal ions after cervical disc arthroplasty: a case report and literature review, Spine (Phila Pa 1976). 34 (2009) E262-5. doi:10.1097/BRS.0b013e318195dd60. [130] M. Lagier, M. Briere, H. Giorgi, S. Fuentes, B. Blondel, P. Tropiano, Delayed hypersensitivity reaction after cervical disc replacement: A case report, Orthop. Traumatol. Surg. Res. 101 (2015) 643–645. doi:10.1016/j.otsr.2015.05.005. [131] M.R. Berry, B.G. Peterson, D.H. Alander, A granulomatous mass surrounding a Maverick total disc replacement causing iliac vein occlusion and spinal stenosis: a case report, J Bone Jt. Surg Am. 92 (2010) 1242–1245. doi:10.2106/JBJS.H.01625. [132] J. Francois, R. Coessens, P. Lauweryns, Early removal of a Maverick disc prosthesis: surgical findings and morphological changes, Acta Orthop Belg. 73 (2007) 122–127. http://www.ncbi.nlm.nih.gov/pubmed/17441671. [133] T.R. Green, J. Fisher, M. Stone, B.M. Wroblewski, E. Ingham, Polyethylene particles of a “critical size” are necessary for the induction of cytokines by macrophages in vitro, Biomaterials. 19 (1998) 2297–2302. http://www.ncbi.nlm.nih.gov/pubmed/9884043. [134] C. Brown, J. Fisher, E. Ingham, Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses, Proc Inst Mech Eng H. 220 (2006) 355–369. http://www.ncbi.nlm.nih.gov/pubmed/16669401. [135] International Organization for Standardization, BS ISO-18192-1:2011 - Implants for surgery - Wear of total intervertebral spinal disc prostheses - Part 1: Loading and displacement parameters for wear testing and corresponding environmental conditions for test, (2011). [136] ASTM, ASTM Standard F2423-11, Stand. Guid. Funct. Kinematic, Wear Assess. Total Disc Prostheses. (2011). doi:10.1520/F2423-11. [137] P.E. Pare, F.W. Chan, S. Bhattacharya, V.K. Goel, Surface slide track mapping of implants for total disc arthroplasty, J Biomech. 42 (2009) 131–139. doi:10.1016/j.jbiomech.2008.10.025. [138] S.M. Kurtz, L. Ciccarelli, M.L. Harper, R. Siskey, J. Shorez, F.W. Chan, Comparison of in vivo and simulator-retrieved metal-on-metal cervical disc replacements, Int. J. Spine Surg. 6 (2012) 145–156. doi:http://dx.doi.org/10.1016/j.ijsp.2012.03.002. [139] S.M.C.F.W. Kurtz Pare P.E, et al., Correlation of in vivo- and simulator-retrieved metal-on-metal cervical disc replacements, 7th Annu. Meet. Spine Arthroplast. Soc. (2007). [140] R.L.. K. Siskey S.M.; Shah, P.; Ciccarelli, L.; Harper, M.; Chan, F.; White, S., Validation of ISO-Standard Wear Testing with Retrieved Metal-on-Metal Cervical Disc Replacements, 54th Annu. Meet. Orthop. Res. Soc. (2008). [141] C.J. Kelly N Wright T, Retrieval analysis of ProDisc total disc replacements, 54th Annu. Meet. Orthop. Res. Soc. (2008). [142] W. Nechtow, M. Bushelow, M. Hintner, A. Ochs, C. Kaddick, Cervical Disc Prosthesis Polyethylene Wear Following The ISO Cervical Test Poster No . 1926 • 54th Annual Meeting of the Orthopaedic Research Society, 1 (2002) 18192. http://www.ors.org/Transactions/54/1926.pdf (accessed April 8, 2017). [143] M. Bushelow, W. Nechtow, M. Hinter, H. Dressel, C. Kaddick, M.E. Gmbh, W. Chester, Wear Testing of a Cervical Total Disc Replacement : Effect of Motion and Load Parameters on Wear Rate and Particle Morphology 1 EndoLab Materials and Methods : All testing was performed at EndoLab Mechanical Engineering GmbH ( Rosenheim , GR ). Testing wa, 29 (2006) 2006. http://www.ors.org/Transactions/54/1925.pdf (accessed April 8, 2017). [144] P.J. Hyde, J. Tipper, J. Fisher, R.M. Hall, Wear and biological effects of a semi-constrained total disc replacement subject to modified ISO standard test conditions, J. Mech. Behav. Biomed. Mater. 44 (2015) 43–52. doi:10.1016/j.jmbbm.2014.12.001. [145] J.L. Tipper, A.L. Galvin, S. Williams, H.M. McEwen, M.H. Stone, E. Ingham, J. Fisher, Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators, J Biomed Mater Res A. 78 (2006) 473–480. doi:10.1002/jbm.a.30824. [146] T.R. Green, J. Fisher, J.B. Matthews, M.H. Stone, E. Ingham, Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles, J Biomed Mater Res. 53 (2000) 490–497. [147] K.M. Holmberg A.`, Coatings Tribology: Properties, Mechanisms, Techniques and Applications in Surface Engineering, 2nd ed., Elsevier, Oxford, 2009. [148] A. Matthews, Advanced surface coatings: a handbook of surface engineering, Blackie, Glasgow, UK, 1991. [149] C. Christou, Z.H. Barber, Ionization of sputtered material in a planar magnetron discharge, J. Vac. Sci. Technol. A Vacuum, Surfaces Film. 18 (2000) 2897–2907. http://www.scopus.com/inward/record.url?eid=2-s2.0-0034318373&partnerID=40&md5=9bf0568125a1666aa8d200f616960e64. [150] T. Shimizu, H. Komiya, T. Watanabe, Y. Teranishi, H. Nagasaka, K. Morikawa, M. Yang, HIPIMS deposition of TiAlN films on inner wall of micro-dies and its applicability in micro-sheet metal forming, Surf. Coatings Technol. 250 (2014) 44–51. doi:http://dx.doi.org/10.1016/j.surfcoat.2014.02.008. [151] V. Kouznetsov, K. MacÁk, J.M. Schneider, U. Helmersson, I. Petrov, A novel pulsed magnetron sputter technique utilizing very high target power densities, Surf. Coatings Technol. 122 (1999) 290–293. http://www.scopus.com/inward/record.url?eid=2-s2.0-0000975178&partnerID=40&md5=997858bd1298305f27622ef858a5185d. [152] K. Sarakinos, J. Alami, S. Konstantinidis, High power pulsed magnetron sputtering: A review on scientific and engineering state of the art, Surf. Coatings Technol. 204 (2010) 1661–1684. doi:http://dx.doi.org/10.1016/j.surfcoat.2009.11.013. [153] D.J. Berry, W.S. Harmsen, M.E. Cabanela, B.F. Morrey, Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components, J Bone Jt. Surg Am. 84–A (2002) 171–177. http://www.ncbi.nlm.nih.gov/pubmed/11861721. [154] P.F. Sharkey, W.J. Hozack, R.H. Rothman, S. Shastri, S.M. Jacoby, Insall Award paper. Why are total knee arthroplasties failing today?, Clin Orthop Relat Res. (2002) 7–13. http://www.ncbi.nlm.nih.gov/pubmed/12439231. [155] S.R.P. Silva, G.A.J. Amaratunga, Doping of rf plasma deposited diamond-like carbon films, Thin Solid Films. 270 (1995) 194–199. http://www.scopus.com/inward/record.url?eid=2-s2.0-0029516498&partnerID=40&md5=0003e753fa6bf960803a73cd8b64c7be. [156] A.A. Evtukh, V.G. Litovchenko, Y.M. Litvin, D. V Fedin, O.S. Dzyan, Y.N. Pedchenko, A.G. Chakhovskoi, T.E. Felter, Silicon doped diamond-like carbon films as a coating for improvement of electron field emission, J. Vac. Sci. Technol. B Microelectron. Nanom. Struct. 21 (2003) 627–630. http://www.scopus.com/inward/record.url?eid=2-s2.0-0037207783&partnerID=40&md5=86bc0f67a96f8795a579b1f4c2576398. [157] T. Wehlus, G. Thorwarth, F. Schwarz, M.F. Schneider, B. Saldamli, B. Stritzker, Biocompatible DLC coatings by PBII: Effects of doping and surface roughness, Phys. Status Solidi Curr. Top. Solid State Phys. 5 (2008) 952–955. http://www.scopus.com/inward/record.url?eid=2-s2.0-77951161128&partnerID=40&md5=4665a22f1d9f2fba0aed0eda204cdd86. [158] R. Hauert, A review of modified DLC coatings for biological applications, Diam. Relat. Mater. 12 (2003) 583–589. http://www.scopus.com/inward/record.url?eid=2-s2.0-0037852937&partnerID=40&md5=92c76a7aa72c017d3e2596873471df95. [159] C. Donnet, Recent progress on the tribology of doped diamond-like and carbon alloy coatings: A review, Surf. Coatings Technol. 100–101 (1998) 180–186. http://www.scopus.com/inward/record.url?eid=2-s2.0-0032026026&partnerID=40&md5=bef4c288e95a27ceb810057aa3792425. [160] L.A. Thomson, F.C. Law, N. Rushton, J. Franks, Biocompatibility of diamond-like carbon coating, Biomaterials. 12 (1991) 37–40. http://www.ncbi.nlm.nih.gov/pubmed/2009344. [161] F.Z. Cui, D.J. Li, A review of investigations on biocompatibility of diamond-like carbon and carbon nitride films, Surf. Coatings Technol. 131 (2000) 481–487. http://www.scopus.com/inward/record.url?eid=2-s2.0-0034532526&partnerID=40&md5=aec0c81c6581d564f930f76ed5f3a155. [162] R.K. Roy, K.R. Lee, Biomedical applications of diamond-like carbon coatings: A review, J. Biomed. Mater. Res. - Part B Appl. Biomater. 83 (2007) 72–84. http://www.scopus.com/inward/record.url?eid=2-s2.0-34648824850&partnerID=40&md5=11bbc5e097fd398dc80cc682ab6f2f01. [163] C.A. Love, R.B. Cook, T.J. Harvey, P.A. Dearnley, R.J.K. Wood, Diamond like carbon coatings for potential application in biological implants—a review, Tribol. Int. 63 (2013) 141–150. doi:http://dx.doi.org/10.1016/j.triboint.2012.09.006. [164] R. Lappalainen, M. Selenius, A. Anttila, Y.T. Konttinen, S.S. Santavirta, Reduction of wear in total hip replacement prostheses by amorphous diamond coatings, J Biomed Mater Res B Appl Biomater. 66 (2003) 410–413. doi:10.1002/jbm.b.10026. [165] S. Affatato, M. Frigo, A. Toni, An in vitro investigation of diamond-like carbon as a femoral head coating, J Biomed Mater Res. 53 (2000) 221–226. [166] J.I. Oñate, M. Comin, I. Braceras, A. Garcia, J.L. Viviente, M. Brizuela, N. Garagorri, J.L. Peris, J.I. Alava, Wear reduction effect on ultra-high-molecular-weight polyethylene by application of hard coatings and ion implantation on cobalt chromium alloy, as measured in a knee wear simulation machine, Surf. Coatings Technol. 142–144 (2001) 1056–1062. doi:http://dx.doi.org/10.1016/S0257-8972(01)01074-X. [167] R. Lappalainen, S.S. Santavirta, Potential of coatings in total hip replacement, Clin. Orthop. Relat. Res. (2005) 72–79. http://www.scopus.com/inward/record.url?eid=2-s2.0-11844275898&partnerID=40&md5=96578c9c52e14919bccd0b8f5727cf56. [168] G Maestretti, D Noriega, P Otten, P.V. R Srour, BAGUERA® C – A New Cervical Disc Replacement Device, 2008. [169] M. Benmekhbi, J. Mortada, G. Lungu, D. Eichler, R. Srour, J.M. Vital, Baguera cervical disc prosthesis, Interact. Surg. 3 (2008) 201–204. doi:10.1007/s11610-008-0086-2. [170] G. Taeger, L.E. Podleska, B. Schmidt, M. Ziegler, D. Nast-Kolb, Comparison of Diamond-Like-Carbon and Alumina-Oxide articulating with Polyethylene in Total Hip Arthroplasty, Materwiss. Werksttech. 34 (2003) 1094–1100. http://www.scopus.com/inward/record.url?eid=2-s2.0-1642488161&partnerID=40&md5=8aa28ada83ec31c9aff7cccdf8a5c7b5. [171] T.J. Joyce, Examination of failed ex vivo metal-on-metal metatarsophalangeal prosthesis and comparison with theoretically determined lubrication regimes, Wear. 263 (2007) 1050–1054. http://www.scopus.com/inward/record.url?eid=2-s2.0-34548061162&partnerID=40&md5=94df9ad38bd20e554d7c21cd39b3ffb0. [172] R. Hauert, C. V Falub, G. Thorwarth, K. Thorwarth, C. Affolter, M. Stiefel, L.E. Podleska, G. Taeger, Retrospective lifetime estimation of failed and explanted diamond-like carbon coated hip joint balls, Acta Biomater. 8 (2012) 3170–3176. doi:10.1016/j.actbio.2012.04.016. [173] R. Hauert, G. Thorwarth, U. Müller, M. Stiefel, C. V Falub, K. Thorwarth, T.J. Joyce, Analysis of the in-vivo failure of the adhesive interlayer for a DLC coated articulating metatarsophalangeal joint, Diam. Relat. Mater. 25 (2012) 34–39. doi:http://dx.doi.org/10.1016/j.diamond.2012.02.001. [174] M.J. Pappas, G. Makris, F.F. Buechel, Titanium nitride ceramic film against polyethylene. A 48 million cycle wear test, Clin Orthop Relat Res. (1995) 64–70. [175] M.T. Raimondi, R. Pietrabissa, The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating, Biomaterials. 21 (2000) 907–913. [176] M.K. Harman, S.A. Banks, W.A. Hodge, Wear analysis of a retrieved hip implant with titanium nitride coating, J Arthroplast. 12 (1997) 938–945. [177] S.N. Massoud, J.B. Hunter, B.J. Holdsworth, W.A. Wallace, R. Juliusson, EARLY FEMORAL LOOSENING IN ONE DESIGN OF CEMENTED HIP REPLACEMENT, Bone Joint J. 79–B (1997). http://bjj.boneandjoint.org.uk/content/79-B/4/603.short (accessed August 26, 2017). [178] G.G. Fuentes, R. Rodriguez, J.C. Avelar-Batista, J. Housden, F. Montalá, L.J. Carreras, A.B. Cristóbal, J.J. Damborenea, T.J. Tate, Recent advances in the chromium nitride PVD process for forming and machining surface protection, J. Mater. Process. Technol. 167 (2005) 415–421. doi:10.1016/j.jmatprotec.2005.06.011. [179] J. Fisher, X.Q. Hu, J.L. Tipper, T.D. Stewart, S. Williams, M.H. Stone, C. Davies, P. Hatto, J. Bolton, M. Riley, C. Hardaker, G.H. Isaac, G. Berry, E. Ingham, An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads, Proc Inst Mech Eng H. 216 (2002) 219–230. [180] S. Williams, G. Isaac, P. Hatto, M.H. Stone, E. Ingham, J. Fisher, Comparative wear under different conditions of surface-engineered metal-on-metal bearings for total hip arthroplasty, J. Arthroplasty. 19 (2004) 112–117. doi:10.1016/j.arth.2004.09.014. [181] W. Österle, D. Klaffke, M. Griepentrog, U. Gross, I. Kranz, C. Knabe, Potential of wear resistant coatings on Ti–6Al–4V for artificial hip joint bearing surfaces, Wear. 264 (2008) 505–517. doi:http://dx.doi.org/10.1016/j.wear.2007.04.001. [182] R. Thorkildsen, O. Reigstad, M. R?kkum, Chrome nitride coating reduces wear of small, spherical CrCoMo metal-on-metal articulations in a joint simulator, J. Hand Surg. (European Vol. 42 (2017) 310–315. doi:10.1177/1753193416674161. [183] I. Leslie, S. Williams, G. Isaac, P. Hatto, E. Ingham, J. Fisher, Wear of surface-engineered metal-on-metal bearings for hip prostheses under adverse conditions with the head loading on the rim of the cup, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 227 (2013) 345–349. doi:10.1177/0954411912468542. [184] I.J. Leslie, Surface Engineering of Metal-on-Metal Hip Surface Replacements, University of Leeds, 2008. [185] D. de Villiers, A. Traynor, S.N. Collins, S. Banfield, J. Housden, J.C. Shelton, Chromium nitride coating for large diameter metal-on-polyethylene hip bearings under extreme adverse hip simulator conditions, Wear. 328 (2015) 363–368. doi:10.1016/j.wear.2015.02.060. [186] M. Mazzocchi, D. Gardini, P.L. Traverso, M.G. Faga, A. Bellosi, On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part II: chemical stability and wear resistance in body environment, J Mater Sci Mater Med. 19 (2008) 2889–2901. doi:10.1007/s10856-008-3437-y. [187] M. Mazzocchi, A. Bellosi, On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part I: processing, microstructure, mechanical properties, cytotoxicity, J. Mater. Sci. Mater. Med. 19 (2008) 2881–2887. doi:10.1007/s10856-008-3417-2. [188] J. Olofsson, M. Pettersson, N. Teuscher, A. Heilmann, K. Larsson, K. Grandfield, C. Persson, S. Jacobson, H. Engqvist, Fabrication and evaluation of SixNy coatings for total joint replacements, J Mater Sci Mater Med. 23 (2012) 1879–1889. doi:10.1007/s10856-012-4625-3. [189] M. Pettersson, T. Berlind, S. Schmidt, S. Jacobson, L. Hultman, C. Persson, H. Engqvist, Structure and composition of silicon nitride and silicon carbon nitride coatings for joint replacements, Surf. Coatings Technol. 235 (2013) 827–834. doi:http://dx.doi.org/10.1016/j.surfcoat.2013.09.008. [190] M. Pettersson, S. Tkachenko, S. Schmidt, T. Berlind, S. Jacobson, L. Hultman, H. Engqvist, C. Persson, Mechanical and tribological behavior of silicon nitride and silicon carbon nitride coatings for total joint replacements, J Mech Behav Biomed Mater. 25 (2013) 41–47. doi:10.1016/j.jmbbm.2013.05.002. [191] E. Laarz, B. V Zhmud, L. Bergström, Dissolution and Deagglomeration of Silicon Nitride in Aqueous Medium, J. Am. Ceram. Soc. 83 (2000) 2394–2400. doi:10.1111/j.1151-2916.2000.tb01567.x. [192] B. V Zhmud, L. Bergström, Dissolution Kinetics of Silicon Nitride in Aqueous Suspension, J. Colloid Interface Sci. 218 (1999) 582–584. doi:http://dx.doi.org/10.1006/jcis.1999.6425. [193] M. Pettersson, M. Bryant, S. Schmidt, H. Engqvist, R.M. Hall, A. Neville, C. Persson, Dissolution behaviour of silicon nitride coatings for joint replacements, Mater. Sci. Eng. C. (2016). doi:10.1016/j.msec.2016.01.049. [194] N. V Boskitskaya, T.S. Bartnitskaya, G.N. Makarenko, V.A. Lavrenko, N.M. Danilenko, N.P. Tel’nikova, Chemical stability of silicon nitride powders in biochemical media, Powder Metall. Met. Ceram. 35 (1996) 497–500. doi:10.1007/BF01355964. [195] R.M. Taylor, J.P. Bernero, A.A. Patel, D.S. Brodke, A.C. Khandkar, SILICON NITRIDE: A NEW MATERIAL FOR SPINAL IMPLANTS, J. Bone Jt. Surgery, Br. Vol. 92–B (2010) 133. http://www.bjjprocs.boneandjoint.org.uk/content/92-B/SUPP_I/133.1.abstract. [196] B.S. Bal, A. Khandkar, R. Lakshminarayanan, I. Clarke, A.A. Hoffman, M.N. Rahaman, Testing of silicon nitride ceramic bearings for total hip arthroplasty, J. Biomed. Mater. Res. Part B Appl. Biomater. 87B (2008) 447–454. doi:10.1002/jbm.b.31123. [197] A. Neumann, C. Unkel, C. Werry, C.U. Herborn, H.R. Maier, C. Ragoss, K. Jahnke, Prototype of a silicon nitride ceramic-based miniplate osteofixation system for the midface, Otolaryngol Head Neck Surg. 134 (2006) 923–930. doi:10.1016/j.otohns.2006.01.022. [198] T.G. Ma S.B., Biological Effects of Wear Debris from Joint Arthroplasties, in: P. Ducheyne (Ed.), Compr. Biomater., Elsevier, Oxford, 2011. [199] M. Navarro, A. Michiardi, O. Castaño, J.A. Planell, Biomaterials in orthopaedics., J. R. Soc. Interface. 5 (2008) 1137–58. doi:10.1098/rsif.2008.0151. [200] J. Fisher, X.Q. Hu, T.D. Stewart, S. Williams, J.L. Tipper, E. Ingham, M.H. Stone, C. Davies, P. Hatto, J. Bolton, M. Riley, C. Hardaker, G.H. Isaac, G. Berry, Wear of surface engineered metal-on-metal hip prostheses, J. Mater. Sci. Mater. Med. 15 (2004) 225–235. doi:10.1023/B:JMSM.0000015482.24542.76. [201] C.Y. Lin, H. Kang, J.P. Rouleau, S.J. Hollister, F.L. Marca, Stress analysis of the interface between cervical vertebrae end plates and the Bryan, Prestige LP, and ProDisc-C cervical disc prostheses: an in vivo image-based finite element study, Spine (Phila Pa 1976). 34 (2009) 1554–1560. doi:10.1097/BRS.0b013e3181aa643b. [202] International Organization for Standardization, ISO-7206-2:2011 - Implants for surgery -- Partial and total hip joint prostheses -- Part 2: Articulating surfaces made of metallic, ceramic and plastics materials, (2011). [203] S.A. Wenzel, D.E. Shepherd, Contact stresses in lumbar total disc arthroplasty, Biomed Mater Eng. 17 (2007) 169–173. [204] J.P. Clewlow, T. Pylios, D.E.T. Shepherd, Soft layer bearing joints for spine arthroplasty, Mater. Des. 29 (2008) 1981–1985. doi:http://dx.doi.org/10.1016/j.matdes.2008.04.008. [205] I.J. Udofia, Z.M. Jin, Elastohydrodynamic lubrication analysis of metal-on-metal hip-resurfacing prostheses, J Biomech. 36 (2003) 537–544. [206] T. Pylios, D.E. Shepherd, Soft layered concept in the design of metacarpophalangeal joint replacement implants, Biomed Mater Eng. 18 (2008) 73–82. [207] ASTM, ASTM Standard F1537-11, Stand. Specif. Wrought Cobalt-28Chromium-6Molybdenum Alloy. Surg. Implant. (UNS R31537, UNS R31538, UNS R31539). (2011). doi:10.1520/F1537-11. [208] A. Khan, J. Philip, P. Hess, Young’s modulus of silicon nitride used in scanning force microscope cantilevers, (n.d.). doi:10.1063/1.1638886͔. [209] J. Jagielski, A.S. Khanna, J. Kucinski, D.S. Mishra, P. Racolta, P. Sioshansi, E. Tobin, J. Thereska, V. Uglov, T. Vilaithong, J. Viviente, S.-Z. Yang, A. Zalar, Effect of chromium nitride coating on the corrosion and wear resistance of stainless steel, (n.d.). [210] L. Mattei, F. Di Puccio, B. Piccigallo, E. Ciulli, Lubrication and wear modelling of artificial hip joints: A review, Tribol. Int. 44 (2011) 532–549. doi:http://dx.doi.org/10.1016/j.triboint.2010.06.010. [211] S. Williams, D. Jalali-Vahid, C. Brockett, Z. Jin, M.H. Stone, E. Ingham, J. Fisher, Effect of swing phase load on metal-on-metal hip lubrication, friction and wear, J. Biomech. 39 (2006) 2274–2281. doi:10.1016/j.jbiomech.2005.07.011. [212] J.Q. Yao, M.P. Laurent, T.S. Johnson, C.R. Blanchard, R.D. Crowninshield, The influences of lubricant and material on polymer/CoCr sliding friction, Wear. 255 (2003) 780–784. doi:10.1016/S0043-1648(03)00180-7. [213] I.G. Goryacheva, Contact Mechanics in Tribology, Springer Netherlands, 2013. https://books.google.co.uk/books?id=G2zuCAAAQBAJ. [214] G.R. Johnson, 1 - Biomechanics of joints, in: P.A. Revell (Ed.), Jt. Replace. Technol., Woodhead Publishing, 2008: pp. 3–30. doi:http://dx.doi.org/10.1533/9781845694807.1.3. [215] B.J. Hamrock, D. Dowson, Elastohydrodynamic Lubrication of Elliptical Contacts for Materials of Low Elastic Modulus I—Fully Flooded Conjunction, J. Lubr. Technol. 100 (1978) 236–245. doi:10.1115/1.3453152. [216] H. Xin, D. Shepherd, K. Dearn, PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis, Open Biomed Eng J. 6 (2012) 73–79. doi:10.2174/1874230001206010073. [217] Arcam, ASTM F75 CoCr Alloy, 2015 (n.d.). http://www.arcam.com/wp-content/uploads/Arcam-ASTM-F75-Cobalt-Chrome.pdf. [218] M.Y.P. Costa, M.L.R. Venditti, M.O.H. Cioffi, H.J.C. Voorwald, V.A. Guimarães, R. Ruas, Fatigue behavior of PVD coated Ti–6Al–4V alloy, Int. J. Fatigue. 33 (2011) 759–765. doi:10.1016/j.ijfatigue.2010.11.007. [219] K. Ando, M.C. Chu, F. Yao, S. Sato, Fatigue strength of crack-healed Si3N4/SiC composite ceramics, Fatigue <html_ent Glyph=“@amp;” ascii=“&”/> Fract. Eng. Mater. Struct. 22 (1999) 897–903. doi:10.1046/j.1460-2695.1999.00210.x. [220] M. Bushelow, W. Nechtow, J. Walker, P8. Metal-on-Metal Lumbar TDR Design: A Theoretical Analysis of the Affect of Diameter Clearance and Surface Finish on Lubrication, Spine J. 8 (2008) 105S. doi:10.1016/j.spinee.2008.06.650. [221] Z.M. Jin, D. Dowson, A full numerical analysis of hydrodynamic lubrication in artificial hip joint replacements constructed from hard materials, Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 213 (1999) 355–370. doi:10.1243/0954406991522310. [222] D. Dowson, C.M. McNie, A.A.J. Goldsmith, Direct experimental evidence of lubrication in a metal-on-metal total hip replacement tested in a joint simulator, Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 214 (2000) 75–86. doi:10.1243/0954406001522822. [223] Z.M. Jin, D. Dowson, J. Fisher, Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus, Proc Inst Mech Eng H. 211 (1997) 247–256. [224] D. Dowson, Basic Tribology, in: D.W. Dowson V (Ed.), An Introd. to Biomech. Joints Jt. Replace., Mechl Eng Publications Limited, London, 1981: pp. 49–60. [225] R. Sonntag, J. Reinders, J.S. Rieger, D.W.W. Heitzmann, J.P. Kretzer, Hard-on-Hard Lubrication in the Artificial Hip under Dynamic Loading Conditions, PLoS One. 8 (2013) e71622. doi:10.1371/journal.pone.0071622. [226] Z.M. Jin, J. Fisher, E. Ingham, Biotribology: Material Design, Lubrication and Wear in Artificial Hip Joints, in: Handb. Lubr. Tribol. Vol. I Appl. Maint., CRC Press, Boca Raton, FL, 2006. [227] D. Dowson, Tribological principles in metal-on-metal hip joint design, Proc Inst Mech Eng H. 220 (2006) 161–171. [228] S.C. Scholes, A. Unsworth, Comparison of friction and lubrication of different hip prostheses, Proc Inst Mech Eng H. 214 (2000) 49–57. [229] S. Zhang, F. Awaja, N. James, D.R. McKenzie, A.J. Ruys, Autohesion of plasma treated semi-crystalline PEEK: Comparative study of argon, nitrogen and oxygen treatments, Colloids Surfaces A Physicochem. Eng. Asp. 374 (2011) 88–95. doi:10.1016/j.colsurfa.2010.11.013. [230] C.-C. Sun, S.-C. Lee, W.-C. Hwang, J.-S. Hwang, I.-T. Tang, Y.-S. Fu, Surface Free Energy of Alloy Nitride Coatings Deposited Using Closed Field Unbalanced Magnetron Sputter Ion Plating, Mater. Trans. 47 (2006) 2533–2539. doi:10.2320/matertrans.47.2533. [231] K. Midtbø, K. Schjølberg-Henriksen, M.M. V Taklo, A. Rønnekleiv, Surface Energy of Fusion Bonded Silicon Nitride to Silicon, (n.d.). http://ma.ecsdl.org/content/MA2005-01/11/519.full.pdf (accessed July 12, 2017). [232] Y. Yan, H. Yang, Y. Su, L. Qiao, Albumin adsorption on CoCrMo alloy surfaces., Sci. Rep. 5 (2015) 18403. doi:10.1038/srep18403. [233] M.A. Wimmer, M.T. Mathew, M.P. Laurent, C. Nagelli, Y. Liao, L.D. Marks, R. Pourzal, A. Fischer, J.J. Jacobs, Tribochemical Reactions in Metal-on-Metal Hip Joints Influence Wear and Corrosion, (2012) 1–18. doi:10.1520/STP156020120050. [234] H. Dong, Y. Nagamatsu, K.-K. Chen, K. Tajima, H. Kakigawa, S. Shi, Y. Kozono, Corrosion behavior of dental alloys in various types of electrolyzed water., Dent. Mater. J. 22 (2003) 482–93. http://www.ncbi.nlm.nih.gov/pubmed/15005226 (accessed February 20, 2017). [235] M.T. Clarke, P.T.H. Lee, A. Arora, R.N. Villar, Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty, Bone Joint J. 85–B (2003). [236] H.P. Sieber, C.B. Rieker, P. Kottig, Analysis of 118 second-generation metal-on-metal retrieved hip implants, J Bone Jt. Surg Br. 81 (1999) 46–50. [237] J.L. Gilbert, C.A. Buckley, J.J. Jacobs, In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling, J. Biomed. Mater. Res. 27 (1993) 1533–1544. doi:10.1002/jbm.820271210. [238] G. Manivasagam, D. Dhinasekaran, A. Rajamanickam, Biomedical Implants: Corrosion and its Prevention -A Review, Recent Patents Corros. Sci. 2 (2010) 40–54. [239] H. Matusiewicz, Potential release of in vivo trace metals from metallic medical implants in the human body: From ions to nanoparticles – A systematic analytical review, Acta Biomater. 10 (2014) 2379–2403. doi:10.1016/j.actbio.2014.02.027. [240] D. Ladon, A. Doherty, R. Newson, J. Turner, M. Bhamra, C.P. Case, Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty, J Arthroplast. 19 (2004) 78–83. [241] H. Pandit, S. Glyn-Jones, P. McLardy-Smith, R. Gundle, D. Whitwell, C.L. Gibbons, S. Ostlere, N. Athanasou, H.S. Gill, D.W. Murray, Pseudotumours associated with metal-on-metal hip resurfacings, J Bone Jt. Surg Br. 90 (2008) 847–851. doi:10.1302/0301-620X.90B7.20213. [242] J. Gallo, S.B. Goodman, Y.T. Konttinen, M. Raska, Particle disease: biologic mechanisms of periprosthetic osteolysis in total hip arthroplasty., Innate Immun. 19 (2013) 213–24. doi:10.1177/1753425912451779. [243] N. Taki, J.M. Tatro, J.L. Nalepka, D. Togawa, V.M. Goldberg, C.M. Rimnac, E.M. Greenfield, Polyethylene and titanium particles induce osteolysis by similar, lymphocyte-independent, mechanisms, J. Orthop. Res. 23 (2005) 376–383. doi:10.1016/j.orthres.2004.08.023. [244] R.P. Van Hove, I.N. Sierevelt, B.J. Van Royen, P.A. Nolte, Titanium-Nitride Coating of Orthopaedic Implants: A Review of the Literature, Biomed Res. Int. 2015 (2015) 1–9. doi:10.1155/2015/485975. [245] J. Olofsson, T.M. Grehk, T. Berlind, C. Persson, S. Jacobson, H. Engqvist, Evaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement, Biomatter. 2 (2012) 94–102. doi:10.4161/biom.20710. [246] B.S. Bal, M.N. Rahaman, Orthopedic applications of silicon nitride ceramics, Acta Biomater. 8 (2012) 2889–2898. doi:http://dx.doi.org/10.1016/j.actbio.2012.04.031. [247] A. Neumann, C. Unkel, C. Werry, C.U. Herborn, H.R. Maier, C. Ragoss, K. Jahnke, [Osteosynthesis in facial bones: silicon nitride ceramic as material], HNO. 54 (2006) 937–942. doi:10.1007/s00106-006-1397-4. [248] A. Corp, First Silicon Nitride Total Hip Replacement, 2013 (2011). http://www.amedicacorp.com/press_releases/amedica_us_spine_enters_the_reconstructive_surgery_market. [249] International Organization for Standardization, ISO-4288:1996 - Geometrical Product Specifications (GPS) -- Surface texture: Profile method -- Rules and procedures for the assessment of surface texture, (1996). [250] International Organization for Standardization, BS EN ISO-3274:1998 - Geometric product specifications (GPS). Surface texture. Profile method. Nominal characteristics of contact (stylus) instruments, (1998). [251] International Organization for Standardization, BS EN ISO-26423:2016 - Fine ceramics (advanced ceramics, advanced technical ceramics). Determination of coating thickness by crater-grinding method, (n.d.). http://shop.bsigroup.com/ProductDetail/?pid=000000000030327990 (accessed February 25, 2017). [252] I.N. Sneddon, The relation between load and penetration in the axisymmetric boussinesq problem for a punch of arbitrary profile, Int. J. Eng. Sci. 3 (1965) 47–57. doi:10.1016/0020-7225(65)90019-4. [253] W.C. Oliver, G.M. Pharr, An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments, J. Mater. Res. 7 (1992) 1564–1583. doi:doi:10.1557/JMR.1992.1564. [254] Heavens, O.S., Some factors influencing the adhesion of films produced by vacuum evaporation, J. Phys. Radium. 11 (1950) 355–360. doi:10.1051/jphysrad:01950001107035500. [255] P. Benjamin, C. Weaver, Measurement of Adhesion of Thin Films, Proc. R. Soc. London. Ser. A. Math. Phys. Sci. 254 (1960) 163 LP-176. http://rspa.royalsocietypublishing.org/content/254/1277/163.abstract. [256] International Organization for Standardization, BS EN 1071-2:2002 - Advanced technical ceramics. Methods of test for ceramic coatings. Determination of coating thickness by the crater grinding method, (n.d.). http://shop.bsigroup.com/ProductDetail/?pid=000000000030115576 (accessed February 25, 2017). [257] H.A. Ching, D. Choudhury, M.J. Nine, N.A. Abu Osman, Effects of surface coating on reducing friction and wear of orthopaedic implants, Sci. Technol. Adv. Mater. 15 (2014) 14402. doi:10.1088/1468-6996/15/1/014402. [258] A.. Ehiasarian, W.-D. Münz, L. Hultman, U. Helmersson, I. Petrov, High power pulsed magnetron sputtered CrNx films, Surf. Coatings Technol. 163–164 (2003) 267–272. doi:10.1016/S0257-8972(02)00479-6. [259] A.. Ehiasarian, P.E. Hovsepian, L. Hultman, U. Helmersson, Comparison of microstructure and mechanical properties of chromium nitride-based coatings deposited by high power impulse magnetron sputtering and by the combined steered cathodic arc/unbalanced magnetron technique, Thin Solid Films. 457 (2004) 270–277. doi:10.1016/j.tsf.2003.11.113. [260] A. Anders, Tutorial: Reactive high power impulse magnetron sputtering (R-HiPIMS), J. Appl. Phys. 121 (2017) 171101. doi:10.1063/1.4978350. [261] P. Hones, R. Sanjines, F. Levy, Characterization of sputter-deposited chromium nitride thin films for hard coatings, Surf. Coatings Technol. 94–95 (1997) 398–402. doi:10.1016/S0257-8972(97)00443-X. [262] E. Broszeit, C. Friedrich, G. Berg, Deposition, properties and applications of PVD CrxN coatings, Surf. Coatings Technol. 115 (1999) 9–16. doi:10.1016/S0257-8972(99)00021-3. [263] A. Lippitz, T. Hübert, XPS investigations of chromium nitride thin films, Surf. Coatings Technol. 200 (2005) 250–253. doi:http://dx.doi.org/10.1016/j.surfcoat.2005.02.091. [264] L. Diéguez, D. Caballero, J. Calderer, M. Moreno, E. Martínez, J. Samitier, Optical Gratings Coated with Thin Si3N4 Layer for Efficient Immunosensing by Optical Waveguide Lightmode Spectroscopy., Biosensors. 2 (2012) 114–26. doi:10.3390/bios2020114. [265] I.O. for Standarisation, Partial and total hip joint prostheses -- Part 2: Articulating surfaces made of metallic, ceramic and plastics materials, Implant. Surg. 7206–2:201 (2011). [266] M. Pettersson, Silicon nitride for total hip replacements, 2015. https://uu.diva-portal.org/smash/get/diva2:797505/FULLTEXT01.pdf (accessed June 4, 2017). [267] F. Zhou, K. Adachi, K. Kato, Influence of deposition parameters on surface roughness and mechanical properties of boron carbon nitride coatings synthesized by ion beam assisted deposition, Thin Solid Films. 497 (2006) 210–217. doi:10.1016/j.tsf.2005.10.070. [268] D.M. Mattox, Handbook of physical vapor deposition (PVD) processing, Noyes Publications, Westwood, New Jersey, USA, 2010. https://books.google.co.uk/books?id=BZUtFQNuNgMC&pg=PA157&lpg=PA157&dq=physical+vapour+deposition+process+position+in+the+chamber&source=bl&ots=PHFirQn4S5&sig=uM693uVER0aLXTYJR-sqZTCoeW4&hl=en&sa=X&ved=0ahUKEwi1mPf0kqTUAhXsJcAKHZMMCTsQ6AEIYDAJ#v=onepage&q (accessed June 4, 2017). [269] C. Fabry, C. Zietz, A. Baumann, R. Bader, Wear Performance of Sequentially Cross-Linked Polyethylene Inserts against Ion-Treated CoCr, TiNbN-Coated CoCr and Al2O3 Ceramic Femoral Heads for Total Hip Replacement, Lubricants. 3 (2015) 14–26. doi:10.3390/lubricants3010014. [270] Aesculap Orthopaedics Columbus ® AS Knee System, (2009). https://www.aesculapimplantsystems.com/assets/base/doc/doc832-askneebrochure.pdf (accessed June 4, 2017). [271] T. Halim, I.C. Clarke, M.D. Burgett-Moreno, T.K. Donaldson, C. Savisaar, J.G. Bowsher, A simulator study of adverse wear with metal and cement debris contamination in metal-on-metal hip bearings., Bone Joint Res. 4 (2014) 29–37. doi:10.1302/2046-3758.43.2000332. [272] C.R. Bragdon, M. Jasty, O.K. Muratoglu, W.H. Harris, Third-Body Wear Testing of a Highly Cross-Linked Acetabular Liner, J. Arthroplasty. 20 (2005) 379–385. doi:10.1016/j.arth.2004.09.035. [273] S.G. Ghalme, A. Mankar, Y. Bhalerao, Biomaterials in Hip Joint Replacement, Int. J. Mater. Sci. Eng. 4 (2016). doi:10.17706/ijmse.2016.4.2.113-125. [274] J. Lackner, W. Waldhauser, L. Major, M. Kot, Tribology and Micromechanics of Chromium Nitride Based Multilayer Coatings on Soft and Hard Substrates, Coatings. 4 (2014) 121–138. doi:10.3390/coatings4010121. [275] L. Cunha, M. Andritschky, K. Pischow, Z. Wang, A. Zarychta, A.S. Miranda, A.M. Cunha, Performance of chromium nitride based coatings under plastic processing conditions, Surf. Coatings Technol. 133 (2000) 61–67. doi:10.1016/S0257-8972(00)00875-6. [276] A. Leyland, A. Matthews, On the significance of the H/E ratio in wear control: a nanocomposite coating approach to optimised tribological behaviour, Wear. 246 (2000) 1–11. doi:10.1016/S0043-1648(00)00488-9. [277] A.A.C. Recco, I.C. Oliveira, M. Massi, H.S. Maciel, A.P. Tschiptschin, Adhesion of reactive magnetron sputtered TINx and TICy coatings to AISI H13 tool steel, Surf. Coatings Technol. 202 (2007) 1078–1083. doi:10.1016/j.surfcoat.2007.07.073. [278] H. Haider, J.N. Weisenburger, F. Namavar, K.L. Garvin, Why We Need Coating Technologies for Hip Replacement Systems, and the Importance of Testing them in Vitro, Oper. Tech. Orthop. (2017). doi:10.1053/j.oto.2017.05.003. [279] Ł. Łapaj, J. Markuszewski, J. Wendland, A. Mróz, M. Wierusz-Kozłowska, Massive failure of TiNbN coating in surface engineered metal-on-metal hip arthroplasty: Retrieval analysis, J. Biomed. Mater. Res. Part B Appl. Biomater. 104 (2016) 1043–1049. doi:10.1002/jbm.b.33421. [280] S. Jiang, B. Jiang, Y. Li, Y. Li, G. Yin, C. Zheng, Friction and wear study of diamond-like carbon gradient coatings on Ti6Al4V substrate prepared by plasma source ion implant-ion beam enhanced deposition, Appl. Surf. Sci. 236 (2004) 285–291. doi:10.1016/j.apsusc.2004.04.032. [281] W. Heinke, A. Leyland, A. Matthews, G. Berg, C. Friedrich, E. Broszeit, Evaluation of PVD nitride coatings, using impact, scratch and Rockwell-C adhesion tests, Thin Solid Films. 270 (1995) 431–438. doi:10.1016/0040-6090(95)06934-8. [282] H. Ollendorf, D. Schneider, A comparative study of adhesion test methods for hard coatings, Surf. Coatings Technol. 113 (1999) 86–102. doi:10.1016/S0257-8972(98)00827-5. [283] Z. Wan, T.F. Zhang, H.-B.-R. Lee, J.H. Yang, W.C. Choi, B. Han, K.H. Kim, S.-H. Kwon, Improved Corrosion Resistance and Mechanical Properties of CrN Hard Coatings with an Atomic Layer Deposited Al2O3 Interlayer, ACS Appl. Mater. Interfaces. 7 (2015) 26716–26725. doi:10.1021/acsami.5b08696. [284] K.-D. Bouzakis, S. Makrimallakis, G. Katirtzoglou, G. Skordaris, S. Gerardis, E. Bouzakis, T. Leyendecker, S. Bolz, W. Koelker, Surface & coatings technology., Surf. Coatings Technol. 205 (2010) 1564–1570. http://publica.fraunhofer.de/documents/N-171875.html (accessed June 10, 2017). [285] E. Adoberg, V. Podgurski, P. Peetsalu, L. Lind, V. Mikli, P. Hvizdos, P. Kulu, The effect of surface pre-treatment and coating post-treatment to the properties of TiN coatings, Est. J. Eng. 18 (2012) 185–192. doi:10.3176/eng.2012.3.03. [286] M. Melancon Paul Hunter, A. Al-Borno, T. Liskiewicz, S. Rao Bassem Salamah Shailesh Dhoke, J. Cortes Xianyi Chen, The Effect of Four Commercially Available Steel Decontamination Processes on the Performance of External Coatings, in: NACE - Int. Corros. Conf. Ser., National Association of Corrosion Engineers International, San Antonio, 2014. http://eprints.whiterose.ac.uk/84172/1/NACE 2014 Paper 4391 External Coatings - Jan 30 2014.pdf (accessed June 10, 2017). [287] H.-G. Willert, G.H. Buchhorn, A. Fayyazi, R. Flury, M. Windler, G. Köster, C.H. Lohmann, Metal-on-Metal Bearings and Hypersensitivity in Patients with Artificial Hip Joints<sbt aid=\"954276\">A Clinical and Histomorphological Study</sbt>, J. Bone Jt. Surg. 87 (2005) 28. doi:10.2106/JBJS.A.02039pp. [288] P. Campbell, E. Ebramzadeh, S. Nelson, K. Takamura, K. De Smet, H.C. Amstutz, Histological Features of Pseudotumor-like Tissues From Metal-on-Metal Hips, Clin. Orthop. Relat. Res. 468 (2010) 2321–2327. doi:10.1007/s11999-010-1372-y. [289] I.J. Leslie, S. Williams, C. Brown, J. Anderson, G. Isaac, P. Hatto, E. Ingham, J. Fisher, Surface engineering: A low wearing solution for metal-on-metal hip surface replacements, J. Biomed. Mater. Res. Part B Appl. Biomater. 90B (2009) 558–565. doi:10.1002/jbm.b.31317. [290] R. Lappalainen, M. Selenius, P.A. Revell, Joint bearing surfaces and replacement joint design, in: P.A. Revell (Ed.), Jt. Replace. Technol., Woodhead Publishing Limited Cambridge, UK, Cambridge, 2008. [291] J. Nevelos, E. Ingham, C. Doyle, R. Streicher, A. Nevelos, W. Walter, J. Fisher, Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns, J Arthroplast. 15 (2000) 7–795. doi:10.1054/arth.2000.8100. [292] A. Essner, G. Schmidig, A. Wang, The clinical relevance of hip joint simulator testing: In vitro and in vivo comparisons, 2005. doi:10.1016/j.wear.2005.02.105. [293] P.J. Firkins, J.L. Tipper, M.R. Saadatzadeh, E. Ingham, M.H. Stone, R. Farrar, J. Fisher, Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator., Biomed. Mater. Eng. 11 (2001) 143–57. http://www.ncbi.nlm.nih.gov/pubmed/11352113 (accessed March 20, 2017). [294] J.L. Tipper, A. Hatton, J.E. Nevelos, E. Ingham, C. Doyle, R. Streicher, A.B. Nevelos, J. Fisher, Alumina–alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations, Biomaterials. 23 (2002) 3441–3448. doi:10.1016/S0142-9612(02)00048-0. [295] A. Wang, A. Essner, Three-body wear of UHMWPE acetabular cups by PMMA particles against CoCr, alumina and zirconia heads in a hip joint simulator, Wear. 250 (2001) 212–216. doi:http://dx.doi.org/10.1016/S0043-1648(01)00643-3. [296] C. Myant, R. Underwood, J. Fan, P.M. Cann, Lubrication of metal-on-metal hip joints: the effect of protein content and load on film formation and wear, J Mech Behav Biomed Mater. 6 (2012) 30–40. doi:10.1016/j.jmbbm.2011.09.008. [297] J. Lefebvre, Viscosity of concentrated protein solutions, Rheol. Acta. 21 (n.d.) 620–625. doi:10.1007/bf01534361. [298] S.C. Scholes, A. Unsworth, The effects of proteins on the friction and lubrication of artificial joints, Proc Inst Mech Eng H. 220 (2006) 687–693. [299] S.M. Kurtz, A.A. Edidin, Spine technology handbook, (2006) xiv, 535 ill. (some col.) 25 cm. http://0-www.engineeringvillage.com.wam.leeds.ac.uk/controller/servlet/OpenURL?genre=book&isbn=9780123693907. [300] P. Moghadas, A. Mahomed, D.W.L. Hukins, D.E.T. Shepherd, Wear in metal-on-metal total disc arthroplasty., Proc. Inst. Mech. Eng. H. 227 (2013) 356–61. doi:10.1177/0954411912471768. [301] T.M. Grupp, H.-J. Meisel, J.A. Cotton, J. Schwiesau, B. Fritz, W. Blömer, V. Jansson, Alternative bearing materials for intervertebral disc arthroplasty, Biomaterials. 31 (2010) 523–531. doi:10.1016/j.biomaterials.2009.09.064. [302] M. Kraft, D. Koch, M. Bushelow, Evaluation of PEEK-on-PEEK as a New Articulation, in: Annu. Meet. Ger. Spine Soc., Hamburg, 2011. http://www.medicalpeek.org/pub_reports/view/143 (accessed April 8, 2017). [303] R. Vicars, P. Prokopovich, T.D. Brown, J.L. Tipper, E. Ingham, J. Fisher, R.M. Hall, The effect of anterior-posterior shear on the wear of CHARITÉ total disc replacement., Spine (Phila. Pa. 1976). 37 (2012) E528-34. doi:10.1097/BRS.0b013e31823cbd6e. [304] P. Moghadas, A. Mahomed, D.E. Shepherd, D.W. Hukins, Wear of the Charité ® lumbar intervertebral disc replacement investigated using an electro-mechanical spine simulator, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 229 (2015) 264–268. doi:10.1177/0954411915576537. [305] P. Prokopovich, S. Perni, J. Fisher, R.M. Hall, Spatial variation of wear on Charité lumbar discs, Acta Biomater. 7 (2011) 3914–3926. doi:10.1016/j.actbio.2011.06.036. [306] F.W. Chan, J.D. Bobyn, J.B. Medley, J.J. Krygier, M. Tanzer, The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants., Clin. Orthop. Relat. Res. (1999) 10–24. http://www.ncbi.nlm.nih.gov/pubmed/10611857 (accessed April 8, 2017). [307] A.A.J. Goldsmith, D. Dowson, G.H. Isaac, J.G. Lancaster, A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 214 (2000) 39–47. doi:10.1243/0954411001535228. [308] G.H. Isaac, J. Thompson, S. Williams, J. Fisher, Metal-on-metal bearings surfaces: materials, manufacture, design, optimization, and alternatives, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 220 (2006) 119–133. doi:10.1243/095441105X68953. [309] C. Duc, P. Salvia, A. Lubansu, V. Feipel, K. Aminian, Objective evaluation of cervical spine mobility after surgery during free-living activity, Clin. Biomech. 28 (2013) 364–369. doi:10.1016/j.clinbiomech.2013.03.006. [310] M. Al-Hajjar, J. Fisher, S. Williams, J.L. Tipper, L.M. Jennings, Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions, J Biomed Mater Res Part B Appl Biomater J Biomed Mater Res Part B. 101101 (2013). doi:10.1002/jbm.b.32824. [311] C. Klapperich, J. Graham, L. Pruitt, M.D. Ries, Failure of a Metal-on-Metal Total Hip Arthroplasty From Progressive Osteolysis, J. Arthroplasty. 14 (1999). http://www.ewp.rpi.edu/hartford/~ernesto/F2012/FWM/Papers/Klapperich-1999-Total-Hip.pdf (accessed April 9, 2017). [312] A. Wang, S. Yue, J.. Bobyn, F.. Chan, J.. Medley, Surface characterization of metal-on-metal hip implants tested in a hip simulator, Wear. 225 (1999) 708–715. doi:10.1016/S0043-1648(98)00384-6. [313] T.J. Joyce, H. Grigg, D.J. Langton, A.V.F. Nargol, Quantification of self-polishing in vivo from explanted metal-on-metal total hip replacements, Tribol. Int. 44 (2011) 513–516. doi:10.1016/j.triboint.2010.04.007. [314] M.L. Scott, J.I. Partin, Reduced Wear Rates and Tribological Properties of Long-Term Retrieved Metal-on-Metal Tha Bearing Components, in: Proc. 45th Meet. Orthop. Res. Soc., Anaheim, California, 1999: p. 851. http://www.ors.org/Transactions/45/0851.PDF (accessed April 9, 2017). [315] P.J. Firkins, J.L. Tipper, M.R. Saadatzadeh, E. Ingham, M.H. Stone, R. Farrar, J. Fisher, Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator., Biomed. Mater. Eng. 11 (2001) 143–57. http://www.ncbi.nlm.nih.gov/pubmed/11352113 (accessed April 8, 2017). [316] K. Vassiliou, A.P. D Elfick, S.C. Scholes, A. Unsworth, The effect of “running-in” on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 220 (2006) 269–277. doi:10.1243/09544119JEIM63. [317] J.L. Tipper, P.J. Firkins, E. Ingham, J. Fisher, M.H. Stone, R. Farrar, Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements., J. Mater. Sci. Mater. Med. 10 (1999) 353–62. http://www.ncbi.nlm.nih.gov/pubmed/15348136 (accessed March 20, 2017). [318] D.S. Park, S. Danyluk, M.J. McNallan, Influence of Tribochemical Reaction Products on Friction and Wear of Silicon Nitride at Elevated Temperatures in Reactive Environments, J. Am. Ceram. Soc. 75 (1992) 3033–3039. doi:10.1111/j.1151-2916.1992.tb04383.x. [319] D. Amutha Rani, Y. Yoshizawa, M.I. Jones, H. Hyuga, K. Hirao, Y. Yamauchi, Comparison of Tribological Behavior Between α-Sialon/Si3N4 and Si3N4/Si3N4 Sliding Pairs in Water Lubrication, J. Am. Ceram. Soc. 88 (2005) 1655–1658. doi:10.1111/j.1551-2916.2005.00274.x. [320] T. Saito, Y. Imada, F. Honda, An analytical observation of the tribochemical reaction of silicon nitride sliding with low friction in aqueous solutions, Wear. 205 (1997) 153–159. doi:http://dx.doi.org/10.1016/S0043-1648(96)07287-0. [321] J. Xu, K. Kato, Formation of tribochemical layer of ceramics sliding in water and its role for low friction, Wear. 245 (2000) 61–75. doi:http://dx.doi.org/10.1016/S0043-1648(00)00466-X. [322] H.A. Richardson, I.C. Clarke, P. Williams, T. Donaldson, H. Oonishi, Precision and accuracy in ceramic-on-ceramic wear analyses: influence of simulator test duration, Proc Inst Mech Eng H. 219 (2005) 401–405. [323] I.C. Clarke, V. Good, P. Williams, D. Schroeder, L. Anissian, A. Stark, H. Oonishi, J. Schuldies, G. Gustafson, Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements, Proc Inst Mech Eng H. 214 (2000) 331–347. [324] H. Oonishi, I.C. Clarke, V. Good, H. Amino, M. Ueno, Alumina hip joints characterized by run-in wear and steady-state wear to 14 million cycles in hip-simulator model, J Biomed Mater Res A. 70 (2004) 523–532. doi:10.1002/jbm.a.30021. [325] B.J. McEntire, B.S. Bal, A. Lakshminarayanan, R. Bock, Silicon Nitride Bearings for Total Joint Arthroplasty, Lubricants. 4 (2016) 1–24. doi:10.3390/lubricants4040035. [326] B.S. Bal, A. Khandkar, R. Lakshminarayanan, I. Clarke, A.A. Hoffman, M.N. Rahaman, Fabrication and Testing of Silicon Nitride Bearings in Total Hip Arthroplasty: Winner of the 2007 “HAP” PAUL Award, J Arthroplast. 24 (2009) 110–116. doi:http://dx.doi.org/10.1016/j.arth.2008.01.300. [327] F. Liu, I.J. Udofia, Z.M. Jin, F. Hirt, C. Rieker, P. Roberts, P. Grigoris, Comparison of Contact Mechanics between a Total Hip Replacement and a Hip Resurfacing with a Metal-On-Metal Articulation, Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 219 (2005) 727–732. doi:10.1243/095440605X31490. [328] M. Royle, Influence of coatings on ion release from large diameter metal-on-metal hip bearings, Queen Mary, University of London, 2012. http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.561233 (accessed April 21, 2017). [329] J.A. Ortega-Saenz, M. Alvarez-Vera, M.A.L. Hernandez-Rodriguez, Biotribological study of multilayer coated metal-on-metal hip prostheses in a hip joint simulator, Wear. 301 (2013) 234–242. doi:10.1016/j.wear.2013.01.024. [330] A. Mohammed, A. Metcalfe, D. Woodnutt, Medium-term outcome of titanium nitride, mobile bearing total knee replacement., Acta Orthop. Belg. 80 (2014) 269–75. http://www.ncbi.nlm.nih.gov/pubmed/25090802 (accessed April 21, 2017). [331] D. Woodnutt, K. Hamelynck, Low metal ion release in patients at up to 8 years following titanium niobium nitride (TiNbN) surface treated metal-on-metal hip arthroplasty, Orthop. Proc. 94–B (2012). http://www.bjjprocs.boneandjoint.org.uk/content/94-B/SUPP_XXXIX/6 (accessed April 21, 2017). [332] D. de Villiers, H. Hothi, H. Khatkar, J. Meswania, G. Blunn, J. Skinner, A. Hart, Lessons from retrievals: Retrievals help understand the reason for revision of coated hip arthroplasties, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 229 (2015) 804–811. doi:10.1177/0954411915611427. [333] P. Bergschmidt, R. Bader, S. Finze, C. Schulze, G. Kundt, W. Mittelmeier, Comparative Study of Clinical and Radiological Outcomes of Unconstrained Bicondylar Total Knee Endoprostheses with Anti-allergic Coating., Open Orthop. J. 5 (2011) 354–60. doi:10.2174/1874325001105010354. [334] A. Miletić, P. Terek, L. Kovačević, M. Vilotić, D. Kakaš, B. Škorić, D. Kukuruzović, Influence of substrate roughness on adhesion of TiN coatings, J. Brazilian Soc. Mech. Sci. Eng. 36 (2014) 293–299. doi:10.1007/s40430-013-0102-2. [335] N. Ravi, R. Markandeya, S. V. Joshi, Effect of substrate roughness on adhesion and tribological properties of nc-TiAlN/a-Si3N4 nanocomposite coatings deposited by cathodic arc PVD process, Surf. Eng. 33 (2017) 7–19. doi:10.1179/1743294415Y.0000000005. [336] M. Belmonte, A.J.S. Fernandes, F.M. Costa, F.J. Oliveira, R.F. Silva, Adhesion behaviour assessment on diamond coated silicon nitride by acoustic emission, Diam. Relat. Mater. 12 (2003) 733–737. doi:10.1016/S0925-9635(02)00305-9. [337] N.I. and the I. of M. National Joint Registry for England, Wales, 13th Annual Report - 2016, n.d. http://www.njrcentre.org.uk/njrcentre/Portals/0/Documents/England/Reports/13th Annual Report/07950 NJR Annual Report 2016 ONLINE REPORT.pdf (accessed March 26, 2017). [338] P.E. Purdue, P. Koulouvaris, B.J. Nestor, T.P. Sculco, The central role of wear debris in periprosthetic osteolysis., HSS J. 2 (2006) 102–13. doi:10.1007/s11420-006-9003-6. [339] W.J. Maloney, R.L. Smith, Periprosthetic osteolysis in total hip arthroplasty: the role of particulate wear debris., Instr. Course Lect. 45 (1996) 171–82. http://www.ncbi.nlm.nih.gov/pubmed/8727736 (accessed March 26, 2017). [340] S.-Y. Yang, W. Ren, Y. Park, A. Sieving, S. Hsu, S. Nasser, P.H. Wooley, Diverse cellular and apoptotic responses to variant shapes of UHMWPE particles in a murine model of inflammation., Biomaterials. 23 (2002) 3535–43. http://www.ncbi.nlm.nih.gov/pubmed/12109677 (accessed March 26, 2017). [341] M. Nine, D. Choudhury, A. Hee, R. Mootanah, N. Osman, Wear Debris Characterization and Corresponding Biological Response: Artificial Hip and Knee Joints, Materials (Basel). 7 (2014) 980–1016. doi:10.3390/ma7020980. [342] M.S. Caicedo, L. Samelko, K. McAllister, J.J. Jacobs, N.J. Hallab, Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms, J. Orthop. Res. 31 (2013) 1633–1642. doi:10.1002/jor.22411. [343] R.S. Tuan, F.Y.-I. Lee, Y. T Konttinen, J.M. Wilkinson, R.L. Smith, Implant Wear Symposium 2007 Biologic Work Group, What are the local and systemic biologic reactions and mediators to wear debris, and what host factors determine or modulate the biologic response to wear particles?, J. Am. Acad. Orthop. Surg. 16 Suppl 1 (2008) S42-8. http://www.ncbi.nlm.nih.gov/pubmed/18612013 (accessed March 28, 2017). [344] V. Sansone, D. Pagani, M. Melato, The effects on bone cells of metal ions released from orthopaedic implants. A review., Clin. Cases Miner. Bone Metab. 10 (2013) 34–40. doi:10.11138/ccmbm/2013.10.1.034. [345] N.J. Hallab, J.J. Jacobs, Biologic effects of implant debris., Bull. NYU Hosp. Jt. Dis. 67 (2009) 182–8. http://www.ncbi.nlm.nih.gov/pubmed/19583551 (accessed March 26, 2017). [346] I. Catelas, J.J. Jacobs, Biologic activity of wear particles., Instr. Course Lect. 59 (2010) 3–16. http://www.ncbi.nlm.nih.gov/pubmed/20415362 (accessed March 28, 2017). [347] T.S. Watters, D.M. Cardona, K.S. Menon, E.N. Vinson, M.P. Bolognesi, L.G. Dodd, Aseptic Lymphocyte-Dominated Vasculitis-Associated Lesion, Am. J. Clin. Pathol. 134 (2010) 886–893. doi:10.1309/AJCPLTNEUAH8XI4W. [348] H.S. Gill, G. Grammatopoulos, S. Adshead, E. Tsialogiannis, E. Tsiridis, Molecular and immune toxicity of CoCr nanoparticles in MoM hip arthroplasty, Trends Mol Med. 18 (2012) 145–155. doi:10.1016/j.molmed.2011.12.002. [349] J.A. D’Antonio, W.N. Capello, M. Naughton, Ceramic bearings for total hip arthroplasty have high survivorship at 10 years, Clin Orthop Relat Res. 470 (2012) 373–381. doi:10.1007/s11999-011-2076-7. [350] D.G. Kang, S.C. Wagner, R.A. Lehman, Osteolysis in the setting of metal-on-metal cervical disc arthroplasty, Spine J. 14 (2014) 1362–1365. doi:10.1016/j.spinee.2014.02.034. [351] S.C. Scholes, A. Unsworth, Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples, J. Mater. Sci. Mater. Med. 12 (2001) 299–303. doi:10.1023/A:1011238902803. [352] International Organization for Standardization, ISO-10993-5:2009 - Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity., (2009). [353] S. Lal, R.M. Hall, J.L. Tipper, A novel method for isolation and recovery of ceramic nanoparticles and metal wear debris from serum lubricants at ultra-low wear rates, Acta Biomater. 42 (2016) 420–428. doi:10.1016/j.actbio.2016.07.004. [354] B. Behl, I. Papageorgiou, C. Brown, R. Hall, J.L. Tipper, J. Fisher, E. Ingham, Biological effects of cobalt-chromium nanoparticles and ions on dural fibroblasts and dural epithelial cells, Biomaterials. 34 (2013) 3547–3558. doi:10.1016/j.biomaterials.2013.01.023. [355] F. Lu, M. Royle, F. V Lali, A.J. Hart, S. Collins, J. Housden, J.C. Shelton, Simple isolation method for the bulk isolation of wear particles from metal on metal bearing surfaces generated in a hip simulator test, J. Mater. Sci. Mater. Med. 23 (2012) 891–901. doi:10.1007/s10856-012-4573-y. [356] K. Ohlendieck, Centrifugation, in: J. Walker (Ed.), Princ. Tech. Biochem. Mol. Biol., Cambridge University Press, Cambridge, 2005: pp. 76–80. [357] International Organization for Standardization, ISO-13322-1:2014 – “Particle size analysis – Image analysis methods. Part 1: Static image analysis methods.,” (2014). [358] J.F. Archard, W. Hirst, The Wear of Metals under Unlubricated Conditions, Proc. R. Soc. A Math. Phys. Eng. Sci. 236 (1956) 397–410. doi:10.1098/rspa.1956.0144. [359] F. Meder, T. Daberkow, L. Treccani, M. Wilhelm, M. Schowalter, A. Rosenauer, L. Mädler, K. Rezwan, Protein adsorption on colloidal alumina particles functionalized with amino, carboxyl, sulfonate and phosphate groups, Acta Biomater. 8 (2012) 1221–1229. doi:10.1016/j.actbio.2011.09.014. [360] C. Brown, S. Williams, J.L. Tipper, J. Fisher, E. Ingham, Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation, J Mater Sci Mater Med. 18 (2007) 819–827. doi:10.1007/s10856-006-0015-z. [361] I. Catelas, J.D. Bobyn, J.B. Medley, J.J. Krygier, D.J. Zukor, O.L. Huk, Size, shape, and composition of wear particles from metal-metal hip simulator testing: Effects of alloy and number of loading cycles, J. Biomed. Mater. Res. 67A (2003) 312–327. doi:10.1002/jbm.a.10088. [362] R. Büscher, G. Täger, W. Dudzinski, B. Gleising, M.A. Wimmer, A. Fischer, Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation, J. Biomed. Mater. Res. Part B Appl. Biomater. 72B (2005) 206–214. doi:10.1002/jbm.b.30132. [363] I. Catelas, J.B. Medley, P.A. Campbell, O.L. Huk, J.D. Bobyn, Comparison ofin vitro within vivo characteristics of wear particles from metal-metal hip implants, J. Biomed. Mater. Res. 70B (2004) 167–178. doi:10.1002/jbm.b.20036. [364] Z. Xia, Y.-M. Kwon, S. Mehmood, C. Downing, K. Jurkschat, D.W. Murray, Characterization of metal-wear nanoparticles in pseudotumor following metal-on-metal hip resurfacing, 2011. doi:10.1016/j.nano.2011.08.002. [365] J.G. Bowsher, A. Hussain, J. Nevelos, Williams, J.C. Shelton, LARGE HEAD DIAMETERS HAVE THE POTENTIAL TO REDUCE ION RELEASE IN METAL-ON-METAL HIP WEAR SIMULATIONS, (n.d.). http://www.ors.org/Transactions/51/1626.pdf (accessed April 29, 2017). [366] M. Boerma, G.R. Burton, J. Wang, L.M. Fink, R.E. McGehee, M. Hauer-Jensen, Comparative expression profiling in primary and immortalized endothelial cells: changes in gene expression in response to hydroxy methylglutaryl-coenzyme A reductase inhibition, Blood Coagul. Fibrinolysis. 17 (2006) 173–180. doi:10.1097/01.mbc.0000220237.99843.a1. [367] E. Lidington, D. Moyes, A. McCormack, M. Rose, A comparison of primary endothelial cells and endothelial cell lines for studies of immune interactions, Transpl. Immunol. 7 (1999) 239–246. doi:10.1016/S0966-3274(99)80008-2. [368] C. Pan, C. Kumar, S. Bohl, U. Klingmueller, M. Mann, Comparative Proteomic Phenotyping of Cell Lines and Primary Cells to Assess Preservation of Cell Type-specific Functions, Mol. Cell. Proteomics. 8 (2009) 443–450. doi:10.1074/mcp.M800258-MCP200. [369] L. Fairbairn, R. Kapetanovic, D.P. Sester, D.A. Hume, The mononuclear phagocyte system of the pig as a model for understanding human innate immunity and disease., J. Leukoc. Biol. 89 (2011) 855–71. doi:10.1189/jlb.1110607. [370] M.A. Germain, A. Hatton, S. Williams, J.B. Matthews, M.H. Stone, J. Fisher, E. Ingham, Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro, Biomaterials. 24 (2003) 469–479. [371] B. Scharf, C.C. Clement, V. Zolla, G. Perino, B. Yan, S.G. Elci, E. Purdue, S. Goldring, F. Macaluso, N. Cobelli, R.W. Vachet, L. Santambrogio, Molecular analysis of chromium and cobalt-related toxicity, Sci. Rep. 4 (2015) 5729. doi:10.1038/srep05729. [372] D. Beyersmann, A. Hartwig, Carcinogenic metal compounds: recent insight into molecular and cellular mechanisms, Arch. Toxicol. 82 (2008) 493–512. doi:10.1007/s00204-008-0313-y. [373] D.G. Barceloux, Cobalt., J. Toxicol. Clin. Toxicol. 37 (1999) 201–6. http://www.ncbi.nlm.nih.gov/pubmed/10382556 (accessed May 1, 2017). [374] A.J. Hart, S.A. Sabah, A.S. Bandi, P. Maggiore, P. Tarassoli, B. Sampson, J. A. Skinner, Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement, Bone Joint J. 93–B (2011) 1308–1313. doi:10.1302/0301-620X.93B10.26249. [375] K. De Smet, R. De Haan, A. Calistri, P. Campbell, E. Ebramzadeh, C. Pattyn, H. Gill, Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing, J. Bone Jt. Surgery-American Vol. 90 (2008) 202–208. doi:10.2106/JBJS.H.00672. [376] J. Daniel, H. Ziaee, C. Pradhan, D.J.W. McMinn, Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings, J. Bone Jt. Surg. - Br. Vol. 91–B (2009) 176–179. doi:10.1302/0301-620X.91B2.21654. [377] E. Dunstan, A.P. Sanghrajka, S. Tilley, P. Unwin, G. Blunn, S.R. Cannon, T.W.R. Briggs, Metal ion levels after metal-on-metal proximal femoral replacements: A 30-YEAR FOLLOW-UP, J. Bone Jt. Surg. - Br. Vol. 87–B (2005) 628–631. doi:10.1302/0301-620X.87B5.15384. [378] A.W. Schaffer, A. Pilger, C. Engelhardt, K. Zweymueller, H.W. Ruediger, Increased blood cobalt and chromium after total hip replacement., J. Toxicol. Clin. Toxicol. 37 (1999) 839–44. http://www.ncbi.nlm.nih.gov/pubmed/10630267 (accessed May 1, 2017). [379] O. Posada, R. Tate, R.M. Meek, M. Grant, In Vitro Analyses of the Toxicity, Immunological, and Gene Expression Effects of Cobalt-Chromium Alloy Wear Debris and Co Ions Derived from Metal-on-Metal Hip Implants, Lubricants. 3 (2015) 539–568. doi:10.3390/lubricants3030539. [380] B. Cappi, S. Neuss, J. Salber, R. Telle, R. Knuchel, H. Fischer, Cytocompatibility of high strength non-oxide ceramics, J Biomed Mater Res A. 93 (2010) 67–76. doi:10.1002/jbm.a.32527. [381] A. Neumann, T. Reske, M. Held, K. Jahnke, C. Ragoß, H.R. Maier, Comparative investigation of the biocompatibility of various silicon nitride ceramic qualities in vitro, J. Mater. Sci. Mater. Med. 15 (2004) 1135–1140. doi:10.1023/B:JMSM.0000046396.14073.92. [382] G. Kotzar, M. Freas, P. Abel, A. Fleischman, S. Roy, C. Zorman, J.M. Moran, J. Melzak, Evaluation of MEMS materials of construction for implantable medical devices, Biomaterials. 23 (2002) 2737–2750. doi:http://dx.doi.org/10.1016/S0142-9612(02)00007-8. [383] R. Kue, A. Sohrabi, D. Nagle, C. Frondoza, D. Hungerford, Enhanced proliferation and osteocalcin production by human osteoblast-like MG63 cells on silicon nitride ceramic discs, Biomaterials. 20 (1999) 1195–1201. doi:http://dx.doi.org/10.1016/S0142-9612(99)00007-1. [384] C.C. Guedes e Silva, O.Z. Higa, J.C. Bressiani, Cytotoxic evaluation of silicon nitride-based ceramics, Mater. Sci. Eng. C. 24 (2004) 643–646. doi:http://dx.doi.org/10.1016/j.msec.2004.08.007. [385] A. Neumann, M. Kramps, C. Ragoß, H.R. Maier, K. Jahnke, Histological and microradiographic appearances of Silicon Nitride and Aluminum Oxide in a rabbit femur implantation model*, Materwiss. Werksttech. 35 (2004) 569–573. doi:10.1002/mawe.200400778. [386] C.R. Howlett, E. McCartney, W. Ching, The effect of silicon nitride ceramic on rabbit skeletal cells and tissue. An in vitro and in vivo investigation, Clin Orthop Relat Res. (1989) 293–304. [387] T.J. Webster, A.A. Patel, M.N. Rahaman, B. Sonny Bal, Anti-infective and osteointegration properties of silicon nitride, poly(ether ether ketone), and titanium implants, Acta Biomater. 8 (2012) 4447–4454. doi:10.1016/j.actbio.2012.07.038. [388] S. Yang, X. Wu, Y. Hu, J. Li, G. Liu, W. Xu, C. Yang, S. Ye, Early and intermediate follow-up results after treatment of degenerative disc disease with the Bryan cervical disc prosthesis: single- and multiple-level, Spine (Phila Pa 1976). 33 (2008) E371-7. doi:10.1097/BRS.0b013e31817343a6. [389] H.L. Karlsson, J. Gustafsson, P. Cronholm, L. Möller, Size-dependent toxicity of metal oxide particles—A comparison between nano- and micrometer size, Toxicol. Lett. 188 (2009) 112–118. doi:10.1016/j.toxlet.2009.03.014. [390] T.T. Liao, Q.Y. Deng, S.S. Li, X. Li, L. Ji, Q. Wang, Y.X. Leng, N. Huang, Evaluation of the Size-Dependent Cytotoxicity of DLC (Diamondlike Carbon) Wear Debris in Arthroplasty Applications, ACS Biomater. Sci. Eng. 3 (2017) 530–539. doi:10.1021/acsbiomaterials.6b00618. [391] I. Papageorgiou, C. Brown, R. Schins, S. Singh, R. Newson, S. Davis, J. Fisher, E. Ingham, C.P. Case, The effect of nano- and micron-sized particles of cobalt-chromium alloy on human fibroblasts in vitro, Biomaterials. 28 (2007) 2946–2958. doi:10.1016/j.biomaterials.2007.02.034. [392] Y.-M. Kwon, Z. Xia, S. Glyn-Jones, D. Beard, H.S. Gill, D.W. Murray, Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophages in vitro, Biomed. Mater. 4 (2009) 25018. doi:10.1088/1748-6041/4/2/025018. [393] R. Liu, C. Kurihara, H. Tsai, P.J. Silvestri, M.I. Bennett, P.F. Pasquina, S.P. Cohen, Classification and Treatment of Chronic Neck Pain, Reg. Anesth. Pain Med. 42 (2017) 52–61. doi:10.1097/AAP.0000000000000505. [394] M.F. Shriver, D.J. Lewis, V.R. Kshettry, B.P. Rosenbaum, E.C. Benzel, T.E. Mroz, Pseudoarthrosis rates in anterior cervical discectomy and fusion: A meta-analysis, Spine J. 15 (2015). doi:10.1016/j.spinee.2015.05.010. [395] M.F. Shriver, D. Lubelski, A.M. Sharma, M.P. Steinmetz, E.C. Benzel, T.E. Mroz, Adjacent segment degeneration and disease following cervical arthroplasty: a systematic review and meta-analysis, Spine J. 16 (2016) 168–181. doi:10.1016/j.spinee.2015.10.032. [396] R. Assaker, K. Ritter-Lang, D. Vardon, S. Litrico, S. Fuentes, M. Putzier, J. Franke, P. Jarzem, P. Guigui, G. Nakach, J.-C. Le Huec, Maverick total disc replacement in a real-world patient population: a prospective, multicentre, observational study, Eur. Spine J. 24 (2015) 2047–2055. doi:10.1007/s00586-015-3918-x. [397] M.F. Gornet, J.K. Burkus, R.F. Dryer, J.H. Peloza, Lumbar Disc Arthroplasty With MAVERICK Disc Versus Stand-Alone Interbody Fusion, Spine (Phila. Pa. 1976). 36 (2011) E1600–E1611. doi:10.1097/BRS.0b013e318217668f. [398] R.D. Guyer, K. Pettine, J.S. Roh, T.A. Dimmig, D. Coric, P.C. McAfee, D.D. Ohnmeiss, Comparison of 2 Lumbar Total Disc Replacements, Spine (Phila. Pa. 1976). 39 (2014) 925–931. doi:10.1097/BRS.0000000000000319. [399] N. Plais, X. Thevenot, A. Cogniet, J. Rigal, J.C. Le Huec, Maverick total disc arthroplasty performs well at 10 years follow-up: a prospective study with HRQL and balance analysis, Eur. Spine J. (2017). doi:10.1007/s00586-017-5065-z. [400] S. Green, Chapter 3 - Compounds and Composite Materials A2 - Kurtz, Steven M, in: PEEK Biomater. Handb., William Andrew Publishing, Oxford, 2012: pp. 23–48. doi:http://dx.doi.org/10.1016/B978-1-4377-4463-7.10003-X. [401] A. Zeh, M. Planert, G. Siegert, P. Lattke, A. Held, W. Hein, Release of Cobalt and Chromium Ions Into the Serum Following Implantation of the Metal-on-Metal Maverick-Type Artificial Lumbar Disc (Medtronic Sofamor Danek), Spine (Phila. Pa. 1976). 32 (2007) 348–352. doi:10.1097/01.brs.0000253599.89694.c0. [402] L.A.G. Marshman, T. Friesem, Y.R. Rampersaud, J.-C. Le Huec, M. Krishna, Subsidence and malplacement with the Oblique Maverick Lumbar Disc Arthroplasty: technical note, Spine J. 8 (2008) 650–655. doi:10.1016/j.spinee.2007.03.010. [403] R. Vanos, L.L. Lildhar, E.A. Lehoux, P.E. Beaulé, I. Catelas, In vitro macrophage response to nanometer-size chromium oxide particles, J. Biomed. Mater. Res. - Part B Appl. Biomater. 102 (2014). doi:10.1002/jbm.b.32991. [404] M. Kraft, Wear Performance of a Peek-on-Peek Bearing under Cervical Loading Conditions and at Different Test Frequencies, Glob. Spine J. 2 (2012) s-0032-1319995-s-0032-1319995. doi:10.1055/s-0032-1319995. [405] S. Williams, J.L. Tipper, E. Ingham, M.H. Stone, J. Fisher, In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 217 (2003) 155–163. doi:10.1243/095441103765212659. [406] International Organization for Standardization, BS ISO-18192-3:2017 - Implants for surgery - Wear of total intervertebral spinal disc prostheses - Part 3: Impingement-wear testing and corresponding environmental conditions for test of lumbar prostheses under adverse kinematic conditions, (2017) 21. [407] S. Wohlfart, S. Gelperina, J. Kreuter, Transport of drugs across the blood–brain barrier by nanoparticles, J. Control. Release. 161 (2012) 264–273. doi:10.1016/j.jconrel.2011.08.017. [408] C. Saraiva, C. Praça, R. Ferreira, T. Santos, L. Ferreira, L. Bernardino, Nanoparticle-mediated brain drug delivery: Overcoming blood–brain barrier to treat neurodegenerative diseases, J. Control. Release. 235 (2016) 34–47. doi:10.1016/j.jconrel.2016.05.044. [409] P.R. Lockman, R.J. Mumper, M.A. Khan, D.D. Allen, Nanoparticle Technology for Drug Delivery Across the Blood-Brain Barrier, Drug Dev. Ind. Pharm. 28 (2002) 1–13. doi:10.1081/DDC-120001481."],"dcterms:accessrights":["public"],"dc:title":["Ceramic coatings for Cervical Total Disc Replacement"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:25:23Z"}