{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:22141"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:22141","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"The Feasibility Of Using Infra-Red Radiation In Determining Tooth-Vitality","abstract":"The aim of this Study was to investigate the feasibility of infra-red radiation determining human tooth-vitality, the basis being that a vital tooth with an internal blood-supply may emit more infra-red radiation and be warmer than a non-vital tooth. The commonest pulp tests are sensibility tests which assess the ability of the nerve fibres within the pulp to respond to a stimulus applied to the tooth, rather than assess the pulp blood-flow. Development of the vitality test involved cooling the tooth-tissues and capturing the emitted infra-red radiation of re-warming with a thermal camera. Cooling and re-warming of tooth-slices enabled calculation of thermal conductivity and thermal diffusivity of the mineralised tissues - enamel and dentine - and production of a thermal map which characterised these. Sixteen extracted human molar teeth were tested in a cross-over-study with simulated vitality at four flow-rates: 0.5ml/min, 0.15ml/min, 0.08ml/min and 0.03ml/min under two conditions: pulsed and non-pulsed. The cross-over-design allowed paired testing of the same tooth and independent testing of two dissimilar teeth. The area under the re-warming curve between vital and non-vital teeth was statistically tested. Statistical significance was shown between the paired vital and non-vital teeth at all pulsed flow-rates, and non-pulsed flow-rates of 0.15ml/min and 0.5ml/min. Only the pulsed flow-rate of 0.5ml/min was significant for dissimilar teeth. A thermal map demonstrated re-warming of the vital tooth before the non-vital tooth. The results suggest infra-red radiation may determine tooth-vitality when the teeth are of the same size and shape, with a blood-flow of 0.03ml/min or above. This could be a realistic blood-flow for the human tooth. Testing teeth of differing size and shape may determine vitality at a blood-flow of 0.5ml/min - higher than realistically expected in the human tooth. Clinically, the vitality test between a vital and non-vital root-treated tooth points to this model being inverted. This may be due to the insulating nature of the materials used to restore the non-vital tooth. Further clinical investigation is justified to validate the vitality test.","abstract_html":"The aim of this Study was to investigate the feasibility of infra-red radiation determining human tooth-vitality, the basis being that a vital tooth with an internal blood-supply may emit more infra-red radiation and be warmer than a non-vital tooth. The commonest pulp tests are sensibility tests which assess the ability of the nerve fibres within the pulp to respond to a stimulus applied to the tooth, rather than assess the pulp blood-flow. Development of the vitality test involved cooling the tooth-tissues and capturing the emitted infra-red radiation of re-warming with a thermal camera. Cooling and re-warming of tooth-slices enabled calculation of thermal conductivity and thermal diffusivity of the mineralised tissues - enamel and dentine - and production of a thermal map which characterised these. Sixteen extracted human molar teeth were tested in a cross-over-study with simulated vitality at four flow-rates: 0.5ml/min, 0.15ml/min, 0.08ml/min and 0.03ml/min under two conditions: pulsed and non-pulsed. The cross-over-design allowed paired testing of the same tooth and independent testing of two dissimilar teeth. The area under the re-warming curve between vital and non-vital teeth was statistically tested. Statistical significance was shown between the paired vital and non-vital teeth at all pulsed flow-rates, and non-pulsed flow-rates of 0.15ml/min and 0.5ml/min. Only the pulsed flow-rate of 0.5ml/min was significant for dissimilar teeth. A thermal map demonstrated re-warming of the vital tooth before the non-vital tooth. The results suggest infra-red radiation may determine tooth-vitality when the teeth are of the same size and shape, with a blood-flow of 0.03ml/min or above. This could be a realistic blood-flow for the human tooth. Testing teeth of differing size and shape may determine vitality at a blood-flow of 0.5ml/min - higher than realistically expected in the human tooth. Clinically, the vitality test between a vital and non-vital root-treated tooth points to this model being inverted. This may be due to the insulating nature of the materials used to restore the non-vital tooth. Further clinical investigation is justified to validate the vitality test.","abstract_has_math":false,"creators":["Lancaster, Paula Elizabeth"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Brettle, David S","Carmichael, Fiona","Clerehugh, Val"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-07","date_published":"2018-07","updated_at":"2026-11-18T22:30:12Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.759784"],"render_values":[{"text":"uk.bl.ethos.759784","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/22141/1/Lancaster%20P.E.%20School%20of%20Dentistry%20PhD%202018.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A22141","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brettle, David S","Carmichael, Fiona","Clerehugh, Val"]},{"key":"dc:creator","label":"Author","values":["Lancaster, Paula Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-07"]},{"key":"dc:date.issued","label":"Date","values":["2018-07"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Restorative Dentistry (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/22141/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.759784"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/22141/1/Lancaster%20P.E.%20School%20of%20Dentistry%20PhD%202018.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The aim of this Study was to investigate the feasibility of infra-red radiation determining human tooth-vitality, the basis being that a vital tooth with an internal blood-supply may emit more infra-red radiation and be warmer than a non-vital tooth. The commonest pulp tests are sensibility tests which assess the ability of the nerve fibres within the pulp to respond to a stimulus applied to the tooth, rather than assess the pulp blood-flow. Development of the vitality test involved cooling the tooth-tissues and capturing the emitted infra-red radiation of re-warming with a thermal camera. Cooling and re-warming of tooth-slices enabled calculation of thermal conductivity and thermal diffusivity of the mineralised tissues - enamel and dentine - and production of a thermal map which characterised these. Sixteen extracted human molar teeth were tested in a cross-over-study with simulated vitality at four flow-rates: 0.5ml/min, 0.15ml/min, 0.08ml/min and 0.03ml/min under two conditions: pulsed and non-pulsed. The cross-over-design allowed paired testing of the same tooth and independent testing of two dissimilar teeth. The area under the re-warming curve between vital and non-vital teeth was statistically tested. Statistical significance was shown between the paired vital and non-vital teeth at all pulsed flow-rates, and non-pulsed flow-rates of 0.15ml/min and 0.5ml/min. Only the pulsed flow-rate of 0.5ml/min was significant for dissimilar teeth. A thermal map demonstrated re-warming of the vital tooth before the non-vital tooth. The results suggest infra-red radiation may determine tooth-vitality when the teeth are of the same size and shape, with a blood-flow of 0.03ml/min or above. This could be a realistic blood-flow for the human tooth. Testing teeth of differing size and shape may determine vitality at a blood-flow of 0.5ml/min - higher than realistically expected in the human tooth. Clinically, the vitality test between a vital and non-vital root-treated tooth points to this model being inverted. This may be due to the insulating nature of the materials used to restore the non-vital tooth. Further clinical investigation is justified to validate the vitality test."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["The Feasibility Of Using Infra-Red Radiation In Determining Tooth-Vitality"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brettle, David S","Carmichael, Fiona","Clerehugh, Val"],"dc:creator":["Lancaster, Paula Elizabeth"],"dc:date":["2018-07"],"dc:date.issued":["2018-07"],"dc:description.abstract":["The aim of this Study was to investigate the feasibility of infra-red radiation determining human tooth-vitality, the basis being that a vital tooth with an internal blood-supply may emit more infra-red radiation and be warmer than a non-vital tooth. The commonest pulp tests are sensibility tests which assess the ability of the nerve fibres within the pulp to respond to a stimulus applied to the tooth, rather than assess the pulp blood-flow. Development of the vitality test involved cooling the tooth-tissues and capturing the emitted infra-red radiation of re-warming with a thermal camera. Cooling and re-warming of tooth-slices enabled calculation of thermal conductivity and thermal diffusivity of the mineralised tissues - enamel and dentine - and production of a thermal map which characterised these. Sixteen extracted human molar teeth were tested in a cross-over-study with simulated vitality at four flow-rates: 0.5ml/min, 0.15ml/min, 0.08ml/min and 0.03ml/min under two conditions: pulsed and non-pulsed. The cross-over-design allowed paired testing of the same tooth and independent testing of two dissimilar teeth. The area under the re-warming curve between vital and non-vital teeth was statistically tested. Statistical significance was shown between the paired vital and non-vital teeth at all pulsed flow-rates, and non-pulsed flow-rates of 0.15ml/min and 0.5ml/min. Only the pulsed flow-rate of 0.5ml/min was significant for dissimilar teeth. A thermal map demonstrated re-warming of the vital tooth before the non-vital tooth. The results suggest infra-red radiation may determine tooth-vitality when the teeth are of the same size and shape, with a blood-flow of 0.03ml/min or above. This could be a realistic blood-flow for the human tooth. Testing teeth of differing size and shape may determine vitality at a blood-flow of 0.5ml/min - higher than realistically expected in the human tooth. Clinically, the vitality test between a vital and non-vital root-treated tooth points to this model being inverted. This may be due to the insulating nature of the materials used to restore the non-vital tooth. Further clinical investigation is justified to validate the vitality test."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.759784"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/22141/1/Lancaster%20P.E.%20School%20of%20Dentistry%20PhD%202018.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Restorative Dentistry (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/22141/"],"dcterms:accessrights":["public"],"dc:title":["The Feasibility Of Using Infra-Red Radiation In Determining Tooth-Vitality"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:30:12Z"}