{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:23017"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:23017","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"The Generation and Control of Ultrasonic Waves in Nonlinear Media","abstract":"The objective of this thesis is to utilise modern open-design ultrasound research platforms to develop new and advance several existing techniques that incorporate nonlinear phenomena. Acoustically, nonlinearity refers to changes in speed of sound, attenuation or elasticity that vary with frequency, temperature or pressure. These effects cannot be linearised by the wave equation and require fluid dynamics and elasticity equations to be fully understood. While this is a hindrance and source of error in many areas of ultrasound such as high-intensity focused ultrasound (HIFU) and medical imaging, nonlinearities do have uses in non-destructive guided wave (GW) testing. These effects are influenced greatly by the transducer surface pressure, and so precise control of the excitation is necessary to achieve the desired nonlinear effect, if any, in the medium. In this thesis, aided by the use of two new research platforms, several new ultrasound techniques were developed. It was shown the frequency content in the electrical waveform is pertinent and so distortion must be minimised. This requirement conflicts with several hardware limitations, however. Accordingly, a genetic algorithm was applied to find novel switched waveform designs. It was found to achieve a 2% granularity in amplitude control with harmonic reduction, where existing waveform designs could not produce any. This fine amplitude control is a requirement for array applications. Following this, a technique to control the direction of GWs without knowledge of the waveguide was devised. Recordings of a propagating GW, induced by the first element of an array transducer, were re-transmitted in a recursive fashion. The effect was that the transducer's transmissions constructively interfered with the transverse wave, causing most of the guided wave energy to travel in the direction of the transducer's spatial influence. Experimental results show a 34 dB enhancement in one direction compared with the other. GWs were then applied to bone for two purposes: for assessment of osteoporosis and for measurement of skull properties to assist transcranial therapy. It was shown that existing methods for obtaining dispersion curves are ineffectual due to limitations in the available sampling area. A signal processing scheme was devised to temporally align transverse dispersive waves so that beamforming style techniques could be applied to prove or disprove the existence of certain modes. The technique in combination with multiplication was applied to numerical, ex vivo and in vivo experiments. It was found to improve the contrast of the higher order modes. The technique could improve the reliability of osteoporosis diagnosis with ultrasound, but may also prove useful for acquiring dispersion images in NDT. Numerically the technique was shown to improve the S3 and A3 mode intensity by 6 dB and 13 dB respectively compared with an existing Fourier method. In skull, a relationship was found between the curved therapeutic array geometry and the delay profile necessary to form GWs in skull. Several numerical models were tested and it was shown that the thickness could be obtained from the group velocity. The estimated maximum error using this technique was 0.2 mm. Since the data is co-registered with the therapeutic elements, this method could be used to improve the accuracy of thermal treatments in the brain. Finally, the application of switched excitation for HIFU was considered. To improve on cost, efficiency and size, alternative excitation methods have the potential to replace the linear amplifier circuitry currently used in HIFU. In this final study, harmonic reduction pulse width modulation (HRPWM) was proposed as an algorithmic solution to the design of switched waveforms. Its appropriateness for HIFU was assessed by design of a high power 5 level unfiltered amplifier and subsequent thermal-only lesioning of ex vivo chicken breast. HRPWM produced symmetric, thermal-only lesions that were the same size as their linear amplifier equivalents (p > 0.05). These results demonstrate that HRPWM can minimise HIFU drive circuity size without the need for filters to remove harmonics or adjustable power supplies to achieve array apodisation. Overall it has been shown in this thesis that precise control of the nonlinear wave phenomena can be afforded when using open-platform ultrasound research hardware. The methods described within may reduce the cost and increase the efficacy of future commercial systems.","abstract_html":"The objective of this thesis is to utilise modern open-design ultrasound research platforms to develop new and advance several existing techniques that incorporate nonlinear phenomena. Acoustically, nonlinearity refers to changes in speed of sound, attenuation or elasticity that vary with frequency, temperature or pressure. These effects cannot be linearised by the wave equation and require fluid dynamics and elasticity equations to be fully understood. While this is a hindrance and source of error in many areas of ultrasound such as high-intensity focused ultrasound (HIFU) and medical imaging, nonlinearities do have uses in non-destructive guided wave (GW) testing. These effects are influenced greatly by the transducer surface pressure, and so precise control of the excitation is necessary to achieve the desired nonlinear effect, if any, in the medium. In this thesis, aided by the use of two new research platforms, several new ultrasound techniques were developed. It was shown the frequency content in the electrical waveform is pertinent and so distortion must be minimised. This requirement conflicts with several hardware limitations, however. Accordingly, a genetic algorithm was applied to find novel switched waveform designs. It was found to achieve a 2% granularity in amplitude control with harmonic reduction, where existing waveform designs could not produce any. This fine amplitude control is a requirement for array applications. Following this, a technique to control the direction of GWs without knowledge of the waveguide was devised. Recordings of a propagating GW, induced by the first element of an array transducer, were re-transmitted in a recursive fashion. The effect was that the transducer&#x27;s transmissions constructively interfered with the transverse wave, causing most of the guided wave energy to travel in the direction of the transducer&#x27;s spatial influence. Experimental results show a 34 dB enhancement in one direction compared with the other. GWs were then applied to bone for two purposes: for assessment of osteoporosis and for measurement of skull properties to assist transcranial therapy. It was shown that existing methods for obtaining dispersion curves are ineffectual due to limitations in the available sampling area. A signal processing scheme was devised to temporally align transverse dispersive waves so that beamforming style techniques could be applied to prove or disprove the existence of certain modes. The technique in combination with multiplication was applied to numerical, ex vivo and in vivo experiments. It was found to improve the contrast of the higher order modes. The technique could improve the reliability of osteoporosis diagnosis with ultrasound, but may also prove useful for acquiring dispersion images in NDT. Numerically the technique was shown to improve the S3 and A3 mode intensity by 6 dB and 13 dB respectively compared with an existing Fourier method. In skull, a relationship was found between the curved therapeutic array geometry and the delay profile necessary to form GWs in skull. Several numerical models were tested and it was shown that the thickness could be obtained from the group velocity. The estimated maximum error using this technique was 0.2 mm. Since the data is co-registered with the therapeutic elements, this method could be used to improve the accuracy of thermal treatments in the brain. Finally, the application of switched excitation for HIFU was considered. To improve on cost, efficiency and size, alternative excitation methods have the potential to replace the linear amplifier circuitry currently used in HIFU. In this final study, harmonic reduction pulse width modulation (HRPWM) was proposed as an algorithmic solution to the design of switched waveforms. Its appropriateness for HIFU was assessed by design of a high power 5 level unfiltered amplifier and subsequent thermal-only lesioning of ex vivo chicken breast. HRPWM produced symmetric, thermal-only lesions that were the same size as their linear amplifier equivalents (p &gt; 0.05). These results demonstrate that HRPWM can minimise HIFU drive circuity size without the need for filters to remove harmonics or adjustable power supplies to achieve array apodisation. Overall it has been shown in this thesis that precise control of the nonlinear wave phenomena can be afforded when using open-platform ultrasound research hardware. The methods described within may reduce the cost and increase the efficacy of future commercial systems.","abstract_has_math":false,"creators":["Adams, Christopher"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Freear, Steven","McLaughlan, James Ross","Cowell, David"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-11","date_published":"2018-11","updated_at":"2026-11-18T22:31:21Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.770048"],"render_values":[{"text":"uk.bl.ethos.770048","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["1 U01 HL121838-01","EP/K029835/1","105615/Z/14/Z","RG170324"],"render_values":[{"text":"1 U01 HL121838-01","href":null,"code":true},{"text":"EP/K029835/1","href":null,"code":true},{"text":"105615/Z/14/Z","href":null,"code":true},{"text":"RG170324","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/23017/1/Adams_CD_Electronic_PhD_2018.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A23017","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Freear, Steven","McLaughlan, James Ross","Cowell, David"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["NHBLI","EPSRC","Wellcome Trust","Royal Society"]},{"key":"dc:creator","label":"Author","values":["Adams, Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-11"]},{"key":"dc:date.issued","label":"Date","values":["2018-11"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Electronic & Electrical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/23017/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["C. Adams, D. M. Cowell, L. Nie, J. R. McLaughlan and S. Freear, `A miniature HIFU excitation scheme to eliminate switching-induced grating lobes and nullify hard tissue attenuation', in Ultrasonics Symposium (IUS), 2017 IEEE International, IEEE, 2017, pp. 1{4. [2] D. Cowell, T. Carpenter, P. Smith, C. Adams, S. Harput and S. Freear, `Modi�ed harmonic reduction pulse width modulation (mHRPWM) for switched excitation of resonant HIFU transducers', in Ultrasonics Sym- posium (IUS), 2018 IEEE International, IEEE, 2018, pp. 1{4. [3] C. Adams, S. Harput, D. Cowell, T. M. Carpenter, D. M. Charutz and S. Freear, `An adaptive array excitation scheme for the unidirectional enhancement of guided waves', IEEE transactions on ultrasonics, fer- roelectrics, and frequency control, vol. 64, no. 2, pp. 441{451, 2017. [4] C. Adams, S. Harput, D. Cowell, S. Freear and D. Charutz, `Specimenagnostic guided wave inspection using recursive feedback', in IEEE In- ternational Ultrasonics Symposium (IUS), IEEE, 2016. [5] C. Adams, S. Harput, D. Cowell and S. Freear, `A phase velocity �lter for the measurement of Lamb wave dispersion', in IEEE International Ultrasonics Symposium (IUS), IEEE, 2016. [6] C. Adams, J. McLaughlan, L. Nie and S. Freear, `Excitation and acquisition of cranial guided waves using a concave array transducer', in Proceedings of Meetings on Acoustics 173EAA, ASA, vol. 30, 2017, p. 055 003. 159 REFERENCES [7] C. Adams, T. M. Carpenter, D. Cowell, S. Freear and J. R. McLaughlan, `HIFU drive system miniaturisation using harmonic reduced pulse width modulation', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2018. [8] T. M. Carpenter, C. Adams, S. Freear, D. Cowell and J. McLaughlan, Five Level Switched High Intensity Focused Ultrasound Driver Design, Jul. 2018. [9] S. R. Ansari, `On the physical researches of al~biruni', Indian Journal of History of Science, vol. 11, 1975. [10] C. B. Boyer and U. C. Merzbach, A history of mathematics. John Wiley & Sons, 2011. [11] G. Galilei, Galileo: Two new sciences (translation by stillman drake of galileo's 1638 discourses and mathematical demonstrations concerning two new sciences), 1974. [12] J. W. S. B. Rayleigh, The theory of sound. Macmillan, 1896, vol. 2. [13] H. Lamb, The dynamical theory of sound. Courier Corporation, 2004. [14] J. Rose, `Recent advances in guided wave NDE', 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium, 1995. doi: 10. 1109/ultsym.1995.495679. [15] G. Ter Haar, `Therapeutic applications of ultrasound', Progress in bio- physics and molecular biology, vol. 93, no. 1, pp. 111{129, 2007. [16] V. A. Khokhlova, M. R. Bailey, J. A. Reed, B. W. Cunitz, P. J. Kaczkowski and L. A. Crum, `E�ects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom', The Journal of the Acoustical Society of America, vol. 119, no. 3, pp. 1834{1848, 2006. [17] S. Harput, Use of chirps in medical ultrasound imaging. University of Leeds, 2012. 160 REFERENCES [18] E. Boni, C. Alfred, S. Freear, J. A. Jensen and P. Tortoli, `Ultrasound open platforms for next-generation imaging technique development', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Con- trol, 2018. [19] A. Marzo, T. Corkett and B. W. Drinkwater, `Ultraino: An open phasedarray system for narrowband airborne ultrasound transmission', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 65, no. 1, pp. 102{111, 2018. [20] E. Boni, L. Bassi, A. Dallai, F. Guidi, V. Meacci, A. Ramalli, S. Ricci and P. Tortoli, `ULA-OP 256: A 256-channel open scanner for development and real-time implementation of new ultrasound methods', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 63, no. 10, pp. 1488{1495, 2016. [21] D. Cowell, T. Carpenter, P. Smith, C. Adams, S. Harput and S. Freear, `Performance of switched mode arbitrary excitation using harmonic reduction pulse width modulation (HRPWM) in array imaging applications', in Ultrasonics Symposium (IUS), 2016 IEEE International, IEEE, 2016, pp. 1{4. [22] L. Nie, S. Harput, D. M. Cowell, T. Carpenter, J. R. McLaughlan and S. Freear, `Combining acoustic trapping with plane wave imaging for localized microbubble accumulation in large vessels', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2018. [23] C. Adams, J. R. McLaughlan, L. Nie, D. Cowell, T. Carpenter and S. Freear, `Excitation of leaky Lamb waves in cranial bone using a phased array transducer in a concave therapeutic con�guration', The Journal of the Acoustical Society of America, 2017. [24] R. Krimholtz, D. A. Leedom and G. L. Matthaei, `New equivalent circuits for elementary piezoelectric transducers', Electronics Letters, vol. 6, no. 13, pp. 398{399, 1970. [25] M. O'Donnell, `Coded excitation system for improving the penetration of real-time phased-array imaging systems', IEEE transactions on ul- 161 REFERENCES trasonics, ferroelectrics, and frequency control, vol. 39, no. 3, pp. 341{ 351, 1992. [26] S. Tang, S. Hui and H. Chung, `A naturally soft-switched high-frequency gate drive circuit for power MOSFETs/IGBTs', in Power Electronics and Drive Systems, 1999. PEDS'99. Proceedings of the IEEE 1999 In- ternational Conference on, IEEE, vol. 1, 1999, pp. 246{252. [27] M. M. El-Desouki and K. Hynynen, `Driving circuitry for focused ultrasound noninvasive surgery and drug delivery applications', Sensors, vol. 11, no. 1, pp. 539{556, 2011. [28] S. D. Kee, `The class E/F family of harmonic-tuned switching power ampli�ers', PhD thesis, California Institute of Technology, 2002. [29] R. Seip, W. Chen, J. Tavakkoli, L. Frizzell and N. Sanghvi, `Highintensity focused ultrasound (HIFU) phased arrays: Recent developments in transrectal transducers and driving electronics design', in Proc. 3rd Int. Symp. on Therapeutic Ultrasound, 2003, pp. 423{428. [30] C. Christo�ersen, W. Wong, S. Pichardo, G. Togtema and L. Curiel, `Class-DE ultrasound transducer driver for HIFU therapy', IEEE trans- actions on biomedical circuits and systems, vol. 10, no. 2, pp. 375{382, 2016. [31] E. Gaalaas, `Class D audio ampli�ers: What, why, and how', Analog Devices Inc., Tech. Rep., 2006. [32] S. C. Tang and G. T. Clement, `A harmonic cancellation technique for an ultrasound transducer excited by a switched-mode power converter', in Ultrasonics Symposium, 2008. IUS 2008. IEEE, IEEE, 2008, pp. 2076{2079. [33] D. Cowell, P. Smith, S. Harput, J. McLaughlan and S. Freear, `Nonlinear harmonic reduction pulse width modulation (HRPWM) for the arbitrary control of transducer-integrated switched excitation electronics', 2014 IEEE International Ultrasonics Symposium, 2014. doi: 10. 1109/ultsym.2014.0198. [34] H. Meire and P. Farrant, Basic ultrasound, 1995. 162 REFERENCES [35] B. W. Drinkwater and P. D. Wilcox, `Ultrasonic arrays for non-destructive evaluation: A review', NDT & E International, vol. 39, no. 7, pp. 525{ 541, 2006, issn: 0963-8695. doi: 10.1016/j.ndteint.2006.03.006. [36] OlympusNDT, Phased array tutorial, 2018. [37] F. Xiaobing and H. Kullervo, `Control of the necrosed tissue volume during noninvasive ultrasound surgery using a 16-element phased array', Medical Physics, vol. 22, no. 3, pp. 297{306, doi: 10.1118/1.597603. eprint: https : / / aapm . onlinelibrary . wiley . com / doi / pdf / 10 . 1118/1.597603. [38] R. S. Cobbold, Foundations of biomedical ultrasound. Oxford University Press, 2006. [39] C. P. Karunakaran and M. L. Oelze, `Amplitude modulated chirp excitation to reduce grating lobes and maintain ultrasound intensity at the focus of an array', Ultrasonics, vol. 53, no. 7, pp. 1293{1303, 2013. [40] E. S. Ebbini, H. Yao and A. Shrestha, `Dual-mode ultrasound phased arrays for image-guided surgery', Ultrasonic Imaging, vol. 28, no. 2, pp. 65{82, 2006, PMID: 17094688. doi: 10.1177/016173460602800201. eprint: http://dx.doi.org/10.1177/016173460602800201. [41] J. A. Jensen, `Field: A program for simulating ultrasound systems', in 10TH NORDICBALTIC CONFERENCE ON BIOMEDICAL IMA- GING, VOL. 4, SUPPLEMENT 1, PART 1: 351{353, Citeseer, 1996. [42] J. Civale, R. Clarke, I. Rivens and G. Ter Haar, `The use of a segmented transducer for rib sparing in HIFU treatments', Ultrasound in medicine & biology, vol. 32, no. 11, pp. 1753{1761, 2006. [43] F. J. �Alvarez and R. Kuc, `Dispersion relation for air via Kramers- Kronig analysis', The Journal of the Acoustical Society of America, vol. 124, no. 2, EL57{EL61, 2008. [44] R. d. L. Kronig, `On the theory of dispersion of x-rays', Josa, vol. 12, no. 6, pp. 547{557, 1926. [45] J. S. Toll, `Causality and the dispersion relation: Logical foundations', Physical review, vol. 104, no. 6, p. 1760, 1956. 163 REFERENCES [46] I. A. Viktorov, Rayleigh and Lamb waves: physical theory and applica- tions. Plenum press, 1970. [47] N. Bochud, Q. Vallet, J.-G. Minonzio and P. Laugier, `Predicting bone strength with ultrasonic guided waves', Scienti�c Reports, vol. 7, p. 43 628, 2017. [48] A. P. Duryea, T. L. Hall, A. D. Maxwell, Z. Xu, C. A. Cain and W. W. Roberts, `Histotripsy erosion of model urinary calculi', Journal of end- ourology, vol. 25, no. 2, pp. 341{344, 2011. [49] B. E. Treeby and B. T. Cox, `K-wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave �elds', Journal of bio- medical optics, vol. 15, no. 2, pp. 021 314{021 314, 2010. [50] J. E. Lingeman, J. A. McAteer, E. Gnessin and A. P. Evan, `Shock wave lithotripsy: Advances in technology and technique', Nature Re- views Urology, vol. 6, no. 12, p. 660, 2009. [51] F. A. Duck, Physical properties of tissues: a comprehensive reference book. Academic press, 2013. [52] M. A. O'Reilly, R. M. Jones and K. Hynynen, `Three-dimensional transcranial ultrasound imaging of microbubble clouds using a sparse hemispherical array', IEEE Transactions on Biomedical Engineering, vol. 61, no. 4, pp. 1285{1294, 2014. [53] D. A. Coley, An introduction to genetic algorithms for scientists and engineers. World Scienti�c Publishing Company, 1999. [54] H. Aytug and G. J. Koehler, `New stopping criterion for genetic algorithms', European Journal of Operational Research, vol. 126, no. 3, pp. 662{674, 2000. [55] S. Baluja and R. Caruana, `Removing the genetics from the standard genetic algorithm', in Machine Learning Proceedings 1995, Elsevier, 1995, pp. 38{46. [56] M. Srinivas and L. M. Patnaik, `Genetic algorithms: A survey', com- puter, vol. 27, no. 6, pp. 17{26, 1994. 164 REFERENCES [57] R. H. Silverman, `High-resolution ultrasound imaging of the eye - a review', Clinical & experimental ophthalmology, vol. 37, no. 1, pp. 54{ 67, 2009. [58] C. Fei, C. T. Chiu, X. Chen, Z. Chen, J. Ma, B. Zhu, K. K. Shung and Q. Zhou, `Ultrahigh frequency (100 MHz-300 MHz) ultrasonic transducers for optical resolution medical imagining', Scienti�c reports, vol. 6, p. 28 360, 2016. [59] K. Xu, D. Ta, B. Hu, P. Laugier and W. Wang, `Wideband dispersion reversal of Lamb waves', IEEE Transactions on Ultrasonics, Ferroelec- trics, and Frequency Control, vol. 61, no. 6, pp. 997{1005, Jun. 2014, issn: 0885-3010. doi: 10.1109/TUFFC.2014.2995. [60] M. Lowe, D. Alleyne and P. Cawley, `Defect detection in pipes using guided waves', Ultrasonics, vol. 36, no. 1{5, pp. 147{154, 1998, Ultrasonics International 1997, issn: 0041-624X. doi: 10.1016/S0041- 624X(97)00038-3. [61] J. Davies and P. Cawley, `The application of synthetic focusing for imaging crack-like defects in pipelines using guided waves', Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on, vol. 56, no. 4, pp. 759{771, 2009. [62] I. Pelivanov, A. Shtokolov, C.-w. Wei and M. O'donnell, `A 1 kHz ascan rate pump-probe laser-ultrasound system for robust inspection of composites', Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on, vol. 62, no. 9, pp. 1696{1703, 2015. doi: 10.1109/ TUFFC.2015.007110. [63] A. K. Edwards, S. Savage, P. L. Hungler and T. W. Krause, `Examination of f/a-18 honeycomb composite rudders for disbond due to water using through-transmission ultrasonics', Ultrasound, vol. 66, no. 2, 2011. doi: 10.5755/j01.u.66.2.529. [64] J. L. Rose, `A baseline and vision of ultrasonic guided wave inspection potential', Journal of Pressure Vessel Technology, vol. 124, no. 3, p. 273, 2002. doi: 10.1115/1.1491272. 165 REFERENCES [65] T. E. Michaels, J. E. Michaels and M. Ruzzene, `Frequency-wavenumber domain analysis of guided wave�elds', Ultrasonics, vol. 51, no. 4, pp. 452{ 466, 2011, issn: 0041-624X. doi: 10.1016/j.ultras.2010.11.011. [66] P. Cawley and D. Alleyne, `The use of Lamb waves for the long range inspection of large structures', Ultrasonics, vol. 34, no. 2{5, pp. 287{290, 1996, Proceedings of Ultrasonics International 1995, issn: 0041-624X. doi: 10.1016/0041-624X(96)00024-8. [67] D. N. Alleyne and P. Cawley, `Optimization of Lamb wave inspection techniques', Ndt & E International, vol. 25, no. 1, pp. 11{22, 1992. [68] P. D. Wilcox, M. J. S. Lowe and P. Cawley, `Mode and transducer selection for long range Lamb wave inspection', Journal of Intelligent Material Systems and Structures, vol. 12, no. 8, pp. 553{565, 2001. doi: 10.1177/10453890122145348. eprint: http://jim.sagepub.com/ content/12/8/553.full.pdf+html. [69] S. Fateri, P. S. Lowe, B. Engineer and N. V. Boulgouris, `Investigation of ultrasonic guided waves interacting with piezoelectric transducers', IEEE Sensors Journal, vol. 15, no. 8, pp. 4319{4328, 2015. [70] A. Croxford, P. Wilcox, B. Drinkwater and G. Konstantinidis, `Strategies for guided-wave structural health monitoring', Proceedings of the Royal Society of London A: Mathematical, Physical and Engineering Sciences, vol. 463, no. 2087, pp. 2961{2981, 2007, issn: 1364-5021. doi: 10.1098/ rspa.2007.0048. eprint: http://rspa.royalsocietypublishing. org/content/463/2087/2961.full.pdf. [71] B. Ren and C. J. Lissenden, `Pvdf multielement Lamb wave sensor for structural health monitoring', IEEE transactions on ultrasonics, ferro- electrics, and frequency control, vol. 63, no. 1, pp. 178{185, 2016. [72] J.-B. Ihn and F.-K. Chang, `Detection and monitoring of hidden fatigue crack growth using a built-in piezoelectric sensor/actuator network: Ii. validation using riveted joints and repair patches', Smart Mater. Struct., vol. 13, no. 3, pp. 621{630, 2004. doi: 10.1088/0964-1726/13/3/021. 166 REFERENCES [73] A. Perelli, L. De Marchi, A. Marzani and N. Speciale, `Acoustic emission localization in plates with dispersion and reverberations using sparse PZT sensors in passive mode', Smart Mater. Struct., vol. 21, no. 2, p. 025 010, 2012. doi: 10.1088/0964-1726/21/2/025010. [74] E. Baravelli, M. Senesi, M. Ruzzene and L. De Marchi, `Fabrication and characterization of a wavenumber-spiral frequency-steerable acoustic transducer for source localization in plate structures', IEEE Trans- actions on Instrumentation and Measurement, vol. 62, no. 8, pp. 2197{ 2204, 2013. doi: 10.1109/tim.2013.2255992. [75] A. Mahmoud, D. Cortes, A. Abaza, H. Ammar, M. Hazey, P. Ngan, R. Crout and O. Mukdadi, `Noninvasive assessment of human jawbone using ultrasonic guided waves', IEEE Transactions on Ultrasonics, Fer- roelectrics, and Frequency Control, vol. 55, no. 6, pp. 1316{1327, Jun. 2008, issn: 0885-3010. doi: 10.1109/TUFFC.2008.794. [76] V. C. Protopappas, D. I. Fotiadis and K. N. Malizos, `Guided ultrasound wave propagation in intact and healing long bones', Ultrasound in medicine & biology, vol. 32, no. 5, pp. 693{708, 2006. [77] J. Foiret, J. G. Minonzio, C. Chappard, M. Talmant and P. Laugier, `Combined estimation of thickness and velocities using ultrasound guided waves: A pioneering study on in vitro cortical bone samples', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 61, no. 9, pp. 1478{1488, Sep. 2014, issn: 0885-3010. doi: 10.1109/TUFFC. 2014.3062. [78] A. Mahmoud, D. Cortes, A. Abaza, H. Ammar, O. Mukdadi, M. Hazey, P. Ngan and R. Crout, `P5A-10 Assessment of human jawbone using ultrasonic guided wave: In vitro study', in Ultrasonics Symposium, 2007. IEEE, Oct. 2007, pp. 2183{2186. doi: 10.1109/ULTSYM.2007.549. [79] P. Moilanen, P. H. Nicholson, V. Kilappa, S. Cheng and J. Timonen, `Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study', Ultrasound in medicine & biology, vol. 33, no. 2, pp. 254{262, 2007. 167 REFERENCES [80] E. Maksuti, E. Widman, D. Larsson, M. W. Urban, M. Larsson and A. Bj�allmark, `Arterial sti�ness estimation by shear wave elastography: Validation in phantoms with mechanical testing', Ultrasound in Medi- cine and Biology, vol. 42, no. 1, pp. 308{321, Mar. 2016, issn: 0301-5629. doi: 10.1016/j.ultrasmedbio.2015.08.012. [81] M. J. S. Lowe, R. E. Challis and C. W. Chan, `The transmission of Lamb waves across adhesively bonded lap joints', The Journal of the Acoustical Society of America, vol. 107, no. 3, pp. 1333{1345, 2000. doi: 10.1121/1.428420. [82] E. Moreno and P. Acevedo, `Thickness measurement in composite materials using Lamb waves', Ultrasonics, vol. 35, no. 8, pp. 581{586, 1998. [83] W. Zhu and J. L. Rose, `Lamb wave generation and reception with timedelay periodic linear arrays: A bem simulation and experimental study', Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on, vol. 46, no. 3, pp. 654{664, 1999. [84] J. L. Rose, Ultrasonic Waves in Solid Media. Cambridge University Press, 1999. [85] V. Dayal and V. K. Kinra, `Leaky Lamb waves in an anisotropic plate. i: An exact solution and experiments', The Journal of the Acoustical Society of America, vol. 85, no. 6, pp. 2268{2276, 1989. doi: 10.1121/ 1.397772. [86] J. Rose, `Guided wave nuances for ultrasonic nondestructive evaluation', IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Con- trol, vol. 47, no. 3, pp. 575{583, 2000. doi: 10.1109/58.842044. [87] P. Khalili and P. Cawley, `Excitation of single-mode Lamb waves at high-frequency-thickness products', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 63, no. 2, pp. 303{312, 2016. [88] P. Fromme, P. Wilcox, M. J. S. Lowe and P. Cawley, `On the development and testing of a guided ultrasonic wave array for structural integrity monitoring', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 53, no. 4, pp. 777{785, Apr. 2006, issn: 0885-3010. doi: 10.1109/TUFFC.2006.1621505. 168 REFERENCES [89] D. Alleyne and P. Cawley, `A two-dimensional fourier transform method for the measurement of propagating multimode signals', The Journal of the Acoustical Society of America, vol. 89, no. 3, pp. 1159{1168, 1991. [90] D. N. Alleyne and P. Cawley, `The interaction of Lamb waves with defects', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 39, no. 3, pp. 381{397, 1992. [91] M. Harb and F. Yuan, `Non-contact ultrasonic technique for Lamb wave characterization in composite plates', Ultrasonics, vol. 64, pp. 162{169, 2016. [92] Y. Cho and J. L. Rose, `A boundary element solution for a mode conversion study on the edge re ection of Lamb waves', The Journal of the Acoustical Society of America, vol. 99, no. 4, pp. 2097{2109, 1996. [93] O. Asfar, B. Morvan and J.-L. Izbicki, `Three-mode coupling of symmetric and antisymmetric Lamb waves in plates with �nite corrugations', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 62, no. 3, pp. 524{530, 2015. [94] P. S. Tua, S. T. Quek and Q. Wang, `Detection of cracks in plates using piezo-actuated Lamb waves', Smart Materials and Structures, vol. 13, no. 4, p. 643, 2004. [95] J. E. Michaels, A. J. Croxford and P. D. Wilcox, `Imaging algorithms for locating damage via in situ ultrasonic sensors', in Sensors Applications Symposium, 2008. SAS 2008. IEEE, Feb. 2008, pp. 63{67. [96] S. Fu, L. Shi, Y. Zhou and J. Cai, `Dispersion compensation in Lamb wave defect detection with step-pulse excitation and warped frequency transform', IEEE Transactions on Ultrasonics, Ferroelectrics, and Fre- quency Control, vol. 61, no. 12, pp. 2075{2088, Dec. 2014, issn: 0885- 3010. doi: 10.1109/TUFFC.2014.006606. [97] X. Chen, J. E. Michaels and T. E. Michaels, `A methodology for estimating guided wave scattering patterns from sparse transducer array measurements', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 62, no. 1, pp. 208{219, 2015. 169 REFERENCES [98] Y. Lu and J. Saniie, `Adaptive �ltering and fractional Fourier transform for ultrasonic signal processsing and aw detection', in Ultrasonics Sym- posium (IUS), 2014 IEEE International, Sep. 2014, pp. 1932{1935. doi: 10.1109/ULTSYM.2014.0480. [99] G. Konstantinidis, P. D. Wilcox and B. W. Drinkwater, `An investigation into the temperature stability of a guided wave structural health monitoring system using permanently attached sensors', IEEE Sensors Journal, vol. 7, no. 5, pp. 905{912, May 2007, issn: 1530-437X. doi: 10.1109/JSEN.2007.894908. [100] J. Bingham and M. Hinders, `Lamb wave detection of delaminations in large diameter pipe coatings', Open Acoustics Journal, vol. 2, pp. 75{ 86, 2009. [101] K. K. Shung, M. B. Smith and B. M. W. Tsui, Principles of medical imaging. Academic Press, 1992. [102] L. Moreau, B. W. Drinkwater and P. D. Wilcox, `Ultrasonic imaging algorithms with limited transmission cycles for rapid nondestructive evaluation', IEEE Transactions on Ultrasonics, Ferroelectrics, and Fre- quency Control, vol. 56, no. 9, pp. 1932{1944, Sep. 2009, issn: 0885- 3010. doi: 10.1109/TUFFC.2009.1269. [103] J. Zhang, B. W. Drinkwater, P. D. Wilcox and A. J. Hunter, `Defect detection using ultrasonic arrays: The multi-mode total focusing method', NDT & E International, vol. 43, no. 2, pp. 123{133, 2010, issn: 0963- 8695. doi: 10.1016/j.ndteint.2009.10.001. [104] C. F. Vasile, `Periodic magnet unidirectional transducer', 4 232 557, Nov. 1980. [105] J. Li and J. L. Rose, `Implementing guided wave mode control by use of a phased transducer array', IEEE transactions on ultrasonics, ferro- electrics, and frequency control, vol. 48, no. 3, pp. 761{768, 2001. [106] D. M. Charutz, E. Mor, S. Harput, D. M. J. Cowell, P. R. Smith and S. Freear, `Guided wave enhancement phased array beamforming scheme using recursive feedback', in 2013 IEEE International Ultrasonics Sym- 170 REFERENCES posium (IUS), Jul. 2013, pp. 166{169. doi: 10.1109/ULTSYM.2013. 0043. [107] A. Gachagan, G. Hayward, A. McNab, P. Reynolds, S. G. Pierce, W. R. Philp and B. Culshaw, `Generation and reception of ultrasonic guided waves in composite plates using conformable piezoelectric transmitters and optical-�ber detectors', IEEE Transactions on Ultrasonics, Ferro- electrics, and Frequency Control, vol. 46, no. 1, pp. 72{81, Jan. 1999, issn: 0885-3010. doi: 10.1109/58.741426. [108] I. Bartoli, A. Marzani, F. L. di Scalea and E. Viola, `Modeling wave propagation in damped waveguides of arbitrary cross-section', Journal of Sound and Vibration, vol. 295, no. 3{5, pp. 685{707, 2006. [109] P. Bocchini, A. Marzani and E. Viola, `Graphical user interface for guided acoustic waves', Journal of Computing in Civil Engineering, vol. 25, no. 3, pp. 202{210, 2011. doi: 10 . 1061 / (ASCE ) CP . 1943 - 5487.0000081. [110] P. N. Marty, N. Desai and J. Andersson, `NDT of kissing bond in aeronautical structures', in 16th World Conference on NDT, 2004. [111] N. Guo and P. Cawley, `The interaction of Lamb waves with delaminations in composite laminates', The Journal of the Acoustical Society of America, vol. 94, no. 4, pp. 2240{2246, 1993. [112] F. L. di Scalea, P. Rizzo and A. Marzani, `Propagation of ultrasonic guided waves in lap-shear adhesive joints: Case of incident a0 Lamb wave', The Journal of the Acoustical Society of America, vol. 115, no. 1, pp. 146{156, 2004. [113] J. B. Harley and J. M. Moura, `Data-driven and calibration-free Lamb wave source localization with sparse sensor arrays', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 62, no. 8, pp. 1516{ 1529, 2015. [114] S. E. Burrows, B. Dutton and S. Dixon, `Laser generation of Lamb waves for defect detection: Experimental methods and �nite element modeling', IEEE Transactions on Ultrasonics, Ferroelectrics, and Fre- 171 REFERENCES quency Control, vol. 59, no. 1, pp. 82{89, Jan. 2012, issn: 0885-3010. doi: 10.1109/TUFFC.2012.2158. [115] R. Levine and J. Michaels, `Block-sparse reconstruction and imaging for Lamb wave structural health monitoring', IEEE Transactions on Ultra- sonics, Ferroelectrics, and Frequency Control, vol. 61, no. 6, pp. 1006{ 1015, Jun. 2014, issn: 0885-3010. doi: 10.1109/TUFFC.2014.2996. [116] J. Hall and J. Michaels, `Minimum variance ultrasonic imaging applied to an in situ sparse guided wave array', IEEE Transactions on Ultra- sonics, Ferroelectrics, and Frequency Control, vol. 57, no. 10, pp. 2311{ 2323, Oct. 2010, issn: 0885-3010. doi: 10.1109/TUFFC.2010.1692. [117] A. Gachagan, P. Reynolds, G. Hayward and A. McNab, `Construction and evaluation of a new generation of exible ultrasonic transducers', in Ultrasonics Symposium, 1996. Proceedings., 1996 IEEE, vol. 2, Nov. 1996, pp. 853{8562. doi: 10.1109/ULTSYM.1996.584127. [118] B. Hailu, G. Hayward, A. Gachagan, A. McNab and R. Farlow, `Comparison of di�erent piezoelectric materials for the design of embedded transducers for structural health monitoring applications', in Ultrason- ics Symposium, 2000 IEEE, vol. 2, Oct. 2000, pp. 1009{10 122. doi: 10.1109/ULTSYM.2000.921495. [119] A. Gachagan, G. Hayward and R. Banks, `A exible piezoelectric transducer design for e�cient generation and reception of ultrasonic Lamb waves', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 52, no. 7, pp. 1175{1182, Jul. 2005, issn: 0885-3010. doi: 10.1109/TUFFC.2005.1504004. [120] P. Marin-Franch, S. Cochran and K. Kirk, `Progress towards ultrasound applications of new single crystal materials', Journal of Materials Sci- ence: Materials in Electronics, vol. 15, no. 11, pp. 715{720, 2004, issn: 1573-482X. doi: 10.1023/B:JMSE.0000043418.10953.38. [121] M. Castaings and P. Cawley, `The generation, propagation, and detection of Lamb waves in plates using air-coupled ultrasonic transducers', The Journal of the Acoustical Society of America, vol. 100, no. 5, pp. 3070{3077, 1996. doi: 10.1121/1.417193. 172 REFERENCES [122] J. E. Michaels, S. J. Lee, A. J. Croxford and P. D. Wilcox, `Chirp excitation of ultrasonic guided waves', Ultrasonics, vol. 53, no. 1, pp. 265{ 270, 2013, issn: 0041-624X. doi: 10.1016/j.ultras.2012.06.010. [123] P. Augat and S. Schorlemmer, `The role of cortical bone and its microstructure in bone strength', Age and ageing, vol. 35, no. suppl 2, pp. ii27{ii31, 2006. [124] S. Bernard, J. Schneider, P. Varga, P. Laugier, K. Raum and Q. Grimal, `Elasticity-density and viscoelasticity-density relationships at the tibia mid-diaphysis assessed from resonant ultrasound spectroscopy measurements', Biomechanics and modeling in mechanobiology, vol. 15, no. 1, pp. 97{109, 2016. [125] Q. Grimal, K. Raum, A. Gerisch and P. Laugier, `A determination of the minimum sizes of representative volume elements for the prediction of cortical bone elastic properties', Biomechanics and Modeling in Mechanobiology, vol. 10, no. 6, pp. 925{937, 2011, issn: 1617-7940. doi: 10.1007/s10237-010-0284-9. [126] P. Droin, G. Berger and P. Laugier, `Velocity dispersion of acoustic waves in cancellous bone', IEEE transactions on ultrasonics, ferroelec- trics, and frequency control, vol. 45, no. 3, pp. 581{592, 1998. [127] N. Bochud, J.-G. Minonzio, Q. Vallet and P. Laugier, `An anisotropic bilayer model to gain insight into in-vivo guided wave measurements', in Ultrasonic Characterization of Bone (ESUCB), 2015 6th European Symposium on, IEEE, 2015, pp. 1{4. [128] P. H. Nicholson, P. Moilanen, T. K�arkk�ainen, J. Timonen and S. Cheng, `Guided ultrasonic waves in long bones: Modelling, experiment and in vivo application', Physiological measurement, vol. 23, no. 4, p. 755, 2002. [129] C. Baron, M. Talmant and P. Laugier, `E�ect of porosity on e�ective diagonal sti�ness coe�cients (CII) and elastic anisotropy of cortical bone at 1 MHz: A �nite-di�erence time domain study', The Journal of the Acoustical Society of America, vol. 122, no. 3, pp. 1810{1817, 2007. 173 REFERENCES [130] J. Y. Rho, R. B. Ashman and C. H. Turner, `Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements', Journal of biomechanics, vol. 26, no. 2, pp. 111{119, 1993. [131] P. Moilanen, `Ultrasonic guided waves in bone', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 55, no. 6, 2008. [132] P. Moilanen, M. Talmant, V. Kilappa, P. Nicholson, S. Cheng, J. Timonen and P. Laugier, `Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius', The Journal of the Acoustical Society of America, vol. 124, no. 4, pp. 2364{2373, 2008. [133] E. Bossy, M. Talmant, M. Defontaine, F. Patat and P. Laugier, `Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: A validation on test materials', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 51, no. 1, pp. 71{79, 2004. [134] C. W. Connor and K. Hynynen, `Patterns of thermal deposition in the skull during transcranial focused ultrasound surgery', IEEE transac- tions on biomedical engineering, vol. 51, no. 10, pp. 1693{1706, 2004. [135] G. Pinton, J.-F. Aubry, E. Bossy, M. Muller, M. Pernot and M. Tanter, `Attenuation, scattering, and absorption of ultrasound in the skull bone', Medical physics, vol. 39, no. 1, pp. 299{307, 2012. [136] R. Sharma and F. Gaillard. (2018). Platybasia, [Online]. Available: https://radiopaedia.org/articles/platybasia. [137] J. A. Kanis et al., `Assessment of osteoporosis at the primary healthcare level', Technical Report. WHO Collaborating Centre, University of She�eld, UK, Tech. Rep., 2008. [138] U.S. Preventive Services Task Force, `Screening for osteoporosis: U.S. preventive services task force recommendation statement', Annals of In- ternal Medicine, vol. 154, no. 5, pp. 356{364, 2011. doi: 10.7326/0003- 4819-154-5-201103010-00307. eprint: /data/journals/aim/20227/ 0000605-201103010-00010.pdf. [Online]. Available: +%20http://dx. doi.org/10.7326/0003-4819-154-5-201103010-00307. 174 REFERENCES [139] N. H. Service, `How it is performed, DEXA (DXA) scan', NHS Health A-Z, 2016. [140] N. I. for Health, `What people with diabetes need to know about osteoporosis', Osteoporosis, 2016, https://www.bones.nih.gov/health- info/bone/osteoporosis/conditions-behaviors/diabetes. [141] S. Prins, H. Jorgensen, L. Jorgensen and C. Hassager, `The role of quantitative ultrasound in the assessment of bone: A review', Clin Physiol, 1997. [142] D. Hans, T. Fuerst and F. Duboeuf, `Quantitative ultrasound bone measurement', European radiology, vol. 7, no. 2, S43, 1997. [143] P. Laugier, `Quantitative ultrasound of bone: Looking ahead', Joint Bone Spine, vol. 73, no. 2, pp. 125{128, 2006. [144] Y. Bala, R. Zebaze and E. Seeman, `Role of cortical bone in bone fragility', Current opinion in rheumatology, vol. 27, no. 4, pp. 406{413, 2015. [145] V. C. Protopappas, I. C. Kourtis, L. C. Kourtis, K. N. Malizos, C. V. Massalas and D. I. Fotiadis, `Three-dimensional �nite element modeling of guided ultrasound wave propagation in intact and healing long bones', The Journal of the Acoustical Society of America, vol. 121, no. 6, pp. 3907{3921, 2007. [146] K. Raum, I. Leguerney, F. Chandelier, E. Bossy, M. Talmant, A. Saied, F. Peyrin and P. Laugier, `Bone microstructure and elastic tissue properties are re ected in QUS axial transmission measurements', Ultra- sound in medicine & biology, vol. 31, no. 9, pp. 1225{1235, 2005. [147] N. O. Kuchuk, N. M. Van Schoor, S. M. Pluijm, J. H. Smit, W. De Ronde and P. Lips, `The association of sex hormone levels with quantitative ultrasound, bone mineral density, bone turnover and osteoporotic fractures in older men and women', Clinical endocrinology, vol. 67, no. 2, pp. 295{303, 2007. 175 REFERENCES [148] V. Egorov, A. Tatarinov, N. Sarvazyan, R. Wood, L. Magidenko, S. Amin, S. Khosla, R. J. Ruh, J. M. Ruh and A. Sarvazyan, `Osteoporosis detection in postmenopausal women using axial transmission multifrequency bone ultrasonometer: Clinical �ndings', Ultrasonics, vol. 54, no. 5, pp. 1170{1177, 2014. [149] A. Sarvazyan, A. Tatarinov, V. Egorov, S. Airapetian, V. Kurtenok and C. J. Gatt, `Application of the dual-frequency ultrasonometer for osteoporosis detection', Ultrasonics, vol. 49, no. 3, pp. 331{337, 2009. [150] E. Bossy, M. Talmant and P. Laugier, `E�ect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: A 2D simulation study', The Journal of the Acoustical Society of America, vol. 112, no. 1, pp. 297{307, 2002. [151] ||, `Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models', The Journal of the Acoustical Society of America, vol. 115, no. 5, pp. 2314{2324, 2004. [152] V. Kilappa, K. Xu, P. Moilanen, E. Heikkola, D. Ta and J. Timonen, `Assessment of the fundamental exural guided wave in cortical bone by an ultrasonic axial-transmission array transducer', Ultrasound in medi- cine & biology, vol. 39, no. 7, pp. 1223{1232, 2013. [153] K. D. Evans, B. Weiss and M. Knopp, `High-intensity focused ultrasound (HIFU) for speci�c therapeutic treatments: A literature review', Journal of Diagnostic Medical Sonography, vol. 23, no. 6, pp. 319{327, 2007. [154] R. Illing, J. Kennedy, F. Wu, G. Ter Haar, A. Protheroe, P. Friend, F. Gleeson, D. Cranston, R. Phillips and M. Middleton, `The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a western population', British journal of cancer, vol. 93, no. 8, p. 890, 2005. [155] M. Huisman, G. Ter Haar, A. Napoli, A. Hananel, P. Ghanouni, G. L�ovey, R. J. Nijenhuis, M. A. Van Den Bosch, V. Rieke, S. Majumdar et al., `International consensus on use of focused ultrasound for painful 176 REFERENCES bone metastases: Current status and future directions', International Journal of Hyperthermia, vol. 31, no. 3, pp. 251{259, 2015. [156] D. Bianchini, F. Marcocci, E. Menghi, V. D'Errico, E. Mezzenga and A. Sarnelli, `Treatment plan veri�cation in MRgFUs for bone metastasis pain palliation', Physica Medica: European Journal of Medical Physics, vol. 32, p. 248, 2016. [157] P. Smirnov and K. Hynynen, `Design of a HIFU array for the treatment of deep venous thrombosis: A simulation study.', Physics in medicine and biology, 2017. [158] A. Partanen, P. S. Yarmolenko, A. Viitala, S. Appanaboyina, D. Haemmerich, A. Ranjan, G. Jacobs, D. Woods, J. Enholm, B. J. Wood et al., `Mild hyperthermia with magnetic resonance-guided high-intensity focused ultrasound for applications in drug delivery', International journal of hyperthermia, vol. 28, no. 4, pp. 320{336, 2012. [159] M. Pernot, J.-F. Aubry, M. Tanter, A.-L. Boch, F. Marquet, M. Kujas, D. Seilhean and M. Fink, `In vivo transcranial brain surgery with an ultrasonic time reversal mirror', Journal of neurosurgery, vol. 106, no. 6, pp. 1061{1066, 2007. [160] J. Blackmore, M. Veldsman, C. Butler and R. Cleveland, `Focusing ultrasound through the skull for neuromodulation', The Journal of the Acoustical Society of America, vol. 141, no. 5, pp. 3549{3549, 2017. [161] O. Naor, S. Krupa and S. Shoham, `Ultrasonic neuromodulation', Journal of neural engineering, vol. 13, no. 3, p. 031 003, 2016. [162] A. Pulkkinen, Y. Huang, J. Song and K. Hynynen, `Simulations and measurements of transcranial low-frequency ultrasound therapy: Skullbase heating and e�ective area of treatment', Physics in Medicine & Biology, vol. 56, no. 15, p. 4661, 2011. [163] M. Pernot, J.-F. Aubry, M. Tanter, J.-L. Thomas and M. Fink, `High power transcranial beam steering for ultrasonic brain therapy', Physics in medicine and biology, vol. 48, no. 16, p. 2577, 2003. 177 REFERENCES [164] G. Clement and K. Hynynen, `A non-invasive method for focusing ultrasound through the human skull', Physics in Medicine & Biology, vol. 47, no. 8, p. 1219, 2002. [165] J. White, G. T. Clement and K. Hynynen, `Transcranial ultrasound focus reconstruction with phase and amplitude correction', IEEEE trans- actions on ultrasonics, ferroelectrics, and frequency control, vol. 52, no. 9, pp. 1518{1522, 2005, https://www.nhs.uk/conditions/dexa- scan/what-happens/. [166] H. Estrada, J. Rebling and D. Razansky, `Prediction and near-�eld observation of skull-guided acoustic waves', Physics in Medicine and Biology, vol. 62, p. 4728, 2017. [167] N. Bochud, J.-G. Minonzio, Q. Vallet and P. Laugier, `A genetic algorithmsbased optimization method for estimating thickness and porosity of cortical bone from guided wave measurements', in Ultrasonic Charac- terization of Bone (ESUCB), 2015 6th European Symposium on, IEEE, 2015, pp. 1{4. [168] P. Moilanen, P. Nicholson, V. Kilappa, S. Cheng and J. Timonen, `Measuring guided waves in long bones: Modeling and experiments in free and immersed plates', Ultrasound in medicine & biology, vol. 32, no. 5, pp. 709{719, 2006. [169] J. L. Rose, Ultrasonic waves in solid media, 2000. [170] K. T. Onwuama, S. O. Salami, M. Ali and J. O. Nzalak, `E�ect of di�erent methods of bone preparation on the skeleton of the African giant pouched rat (cricetomys gambianus).', International Journal of Morphology, vol. 30, no. 2, 2012. [171] L. G. Mandarano-Filho, M. T. Bezuti, N. Mazzer and C. H. Barbieri, `In uence of cortical bone thickness on the ultrasound velocity', Acta ortopedica brasileira, vol. 20, no. 3, pp. 184{190, 2012. [172] S. Qiao, X. Shang and E. Pan, `Elastic guided waves in a coated spherical shell', Nondestructive Testing and Evaluation, vol. 31, no. 2, pp. 165{ 190, 2016. 178 REFERENCES [173] A. N. Norris and A. Shuvalov, `Elastodynamics of radially inhomogeneous spherically anisotropic elastic materials in the stroh formalism', in Proc. R. Soc. A, The Royal Society, vol. 468, 2012, pp. 467{484. [174] J. Qu, Y. Berthelot and Z. Li, `Dispersion of guided circumferential waves in a circular annulus', 1996. [175] G. Gaunaurd and M. Werby, `Similarities between various Lamb waves in submerged spherical shells, and rayleigh waves in elastic spheres and at half-spaces', The Journal of the Acoustical Society of Amer- ica, vol. 89, no. 6, pp. 2731{2739, 1991. [176] W. Sachse and Y.-H. Pao, `On the determination of phase and group velocities of dispersive waves in solids', Journal of Applied Physics, vol. 49, no. 8, pp. 4320{4327, 1978. [177] L. Ma�zeika and L. Draudvilien_e, `Analysis of the zero-crossing technique in relation to measurements of phase velocities of the Lamb waves', Ultrasound, vol. 66, no. 2, pp. 7{12, 2010. [178] T. Pialucha, C. Guyott and P. Cawley, `Amplitude spectrum method for the measurement of phase velocity', Ultrasonics, vol. 27, no. 5, pp. 270{ 279, 1989. [179] D. Waltisberg and R. Rai�sutis, `Group velocity estimation of Lamb waves based on the wavelet transform', Ultragarsas (Ultrasound), vol. 63, no. 4, pp. 35{40, 2008. [180] D. N. Alleyne and P. Cawley, `A 2-dimensional Fourier transform method for the quantitative measurement of Lamb modes', in Ultrasonics Sym- posium, 1990. Proceedings., IEEE 1990, IEEE, 1990, pp. 1143{1146. [181] M. Niethammer, L. J. Jacobs, J. Qu and J. Jarzynski, `Time-frequency representations of Lamb waves', The Journal of the Acoustical Society of America, vol. 109, no. 5, pp. 1841{1847, 2001. [182] J.-G. Minonzio, M. Talmant and P. Laugier, `Measurement of guided mode wave vectors by analysis of the transfer matrix obtained with multi-emitters and multi-receivers in contact', in Journal of Physics: Conference Series, IOP Publishing, vol. 269, 2011, p. 012 003. 179 REFERENCES [183] J.-G. Minonzio, M. Talmant and P. Laugier, `Guided wave phase velocity measurement using multi-emitter and multi-receiver arrays in the axial transmission con�guration', The Journal of the Acoustical Society of America, vol. 127, no. 5, pp. 2913{2919, 2010. [184] G. Matrone, A. Savoia, G. Caliano and G. Magenes, `The delay multiply and sum beamforming algorithm in ultrasound b-mode medical imaging.', IEEE Trans. Med. Imaging, vol. 34, no. 4, pp. 940{949, 2015. [185] D.-a. Ta, K. Huang, W.-q. Wang, Y.-y. Wang and L. H. Le, `Identi�cation and analysis of multimode guided waves in tibia cortical bone', Ultrasonics, vol. 44, e279{e284, 2006. [186] J.-G. Minonzio, J. Foiret, P. Moilanen, J. Pirhonen, Z. Zhao, M. Talmant, J. Timonen and P. Laugier, `A free plate model can predict guided modes propagating in tubular bone-mimicking phantoms', The Journal of the Acoustical Society of America, vol. 137, no. 1, EL98{EL104, 2015. [187] P. Ghanouni, K. B. Pauly, W. J. Elias, J. Henderson, J. Sheehan, S. Monteith and M. Wintermark, `Transcranial MRI-guided focused ultrasound: A review of the technologic and neurologic applications', Amer- ican Journal of Roentgenology, vol. 205, no. 1, pp. 150{159, 2015. [188] G. Ter Haar, `Ultrasound focal beam surgery', Ultrasound in medicine & biology, vol. 21, no. 9, pp. 1089{1100, 1995. [189] M. Lee, D. Schlesinger, G. ter Haar, B. Sela, M. Eames, J. Snell, A. Hananel, N. Kassell, J. Sheehan, J. Larner et al., `Thermal dose and radiation dose comparison based on cell survival', Journal of Therapeutic Ultrasound, vol. 3, no. 1, P26, 2015. [190] Z. Izadifar, P. Babyn and D. Chapman, `Mechanical and biological effects of ultrasound: A review of present knowledge', Ultrasound in Medi- cine & Biology, 2017. [191] J. R. McLaughlan, D. M. Cowell and S. Freear, `Gold nanoparticle nucleated cavitation for enhanced high intensity focused ultrasound therapy', Physics in medicine and biology, 2017. 180 REFERENCES [192] C. J. Diederich, `Thermal ablation and high-temperature thermal therapy: Overview of technology and clinical implementation', International journal of hyperthermia, vol. 21, no. 8, pp. 745{753, 2005. [193] L. Zhang and Z.-B.Wang, `High-intensity focused ultrasound tumor ablation: Review of ten years of clinical experience', Frontiers of medicine in China, vol. 4, no. 3, pp. 294{302, 2010. [194] J. E. Kennedy, `High-intensity focused ultrasound in the treatment of solid tumours', Nature reviews cancer, vol. 5, no. 4, pp. 321{327, 2005. [195] A. Blana, F. J. Murat, B. Walter, S. Thuro�, W. F. Wieland, C. Chaussy and A. Gelet, `First analysis of the long-term results with transrectal HIFU in patients with localised prostate cancer', European urology, vol. 53, no. 6, pp. 1194{1203, 2008. [196] N. Sanghvi, F. J. Fry, R. Bihrle, R. Foster, M. Phillips, J. Syrus, A. Zaitsev and C. Hennige, `Noninvasive surgery of prostate tissue by highintensity focused ultrasound', IEEE Transactions on Ultrasonics, Fer- roelectrics, and Frequency Control, vol. 43, no. 6, pp. 1099{1110, 1996. [197] M. Peek, M. Ahmed, A. Napoli, B. ten Haken, S. McWilliams, S. Usiskin, S. Pinder, M. Van Hemelrijck and M. Douek, `Systematic review of high-intensity focused ultrasound ablation in the treatment of breast cancer', British journal of surgery, vol. 102, no. 8, pp. 873{882, 2015. [198] D. Coluccia, J. Fandino, L. Schwyzer, R. O'Gorman, L. Remonda, J. Anon, E. Martin and B.Werner, `First noninvasive thermal ablation of a brain tumor with MR-guided focusedultrasound', Journal of therapeutic ultrasound, vol. 2, no. 1, p. 17, 2014. [199] K. Hynynen, G. T. Clement, N. McDannold, N. Vykhodtseva, R. King, P. J. White, S. Vitek and F. A. Jolesz, `500-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls', Magnetic resonance in medi- cine, vol. 52, no. 1, pp. 100{107, 2004. 181 REFERENCES [200] H. Gr�ull and S. Langereis, `Hyperthermia-triggered drug delivery from temperature-sensitive liposomes using MRI-guided high intensity focused ultrasound', Journal of Controlled Release, vol. 161, no. 2, pp. 317{ 327, 2012. [201] D. B. Rodrigues, P. R. Stau�er, D. Vrba and M. D. Hurwitz, `Focused ultrasound for treatment of bone tumours', International Journal of Hyperthermia, vol. 31, no. 3, pp. 260{271, 2015. [202] T. R. Wang, R. Dallapiazza and W. J. Elias, `Neurological applications of transcranial high intensity focused ultrasound', International Journal of Hyperthermia, vol. 31, no. 3, pp. 285{291, 2015. [203] J. Xiao, Z. Shi, J. Zhou, J. Ye, J. Zhu, X. Zhou, F. Wang and S. Zhang, `Cesarean scar pregnancy: Comparing the e�cacy and tolerability of treatment with high-intensity focused ultrasound and uterine artery embolization', Ultrasound in medicine & biology, vol. 43, no. 3, pp. 640{ 647, 2017. [204] M. Brown, P. Farquhar-Smith, J. Williams, G. Ter Haar and N. de- Souza, `The use of high-intensity focused ultrasound as a novel treatment for painful conditions a description and narrative review of the literature', BJA: British Journal of Anaesthesia, vol. 115, no. 4, pp. 520{ 530, 2015. [205] M. S. Canney, M. R. Bailey, L. A. Crum, V. A. Khokhlova and O. A. Sapozhnikov, `Acoustic characterization of high intensity focused ultrasound �elds: A combined measurement and modeling approach', J Acoust Soc Am, vol. 124, no. 4, pp. 2406{2420, Oct. 2008, 014810JAS[PII], issn: 0001-4966. doi: 10.1121/1.2967836. [Online]. Available: http: //www.ncbi.nlm.nih.gov/pmc/articles/PMC2677345/. [206] C. A. Cain and S. Umemura, `Concentric-ring and sector-vortex phasedarray applicators for ultrasound hyperthermia', IEEE Transactions on Microwave Theory and Techniques, vol. 34, no. 5, pp. 542{551, May 1986, issn: 0018-9480. doi: 10.1109/TMTT.1986.1133390. 182 REFERENCES [207] P. J. Benkeser, `Unfocused multielement and tapered phased array ultrasound transducers for hyperthermia treatment', PhD thesis, University of Illinois, 1985. [208] J. Sun and K. Hynynen, `The potential of transskull ultrasound therapy and surgery using the maximum available skull surface area', The Journal of the Acoustical Society of America, vol. 105, no. 4, pp. 2519{ 2527, 1999. [209] E. L. Carstensen, S. Z. Child, S. Norton and W. Nyborg, `Ultrasonic heating of the skull', The Journal of the Acoustical Society of America, vol. 87, no. 3, pp. 1310{1317, 1990. [210] F. Fry and J. Barger, `Acoustical properties of the human skull', The Journal of the Acoustical Society of America, vol. 63, no. 5, pp. 1576{ 1590, 1978. [211] G. Clement and K. Hynynen, `Correlation of ultrasound phase with physical skull properties', Ultrasound in medicine & biology, vol. 28, no. 5, pp. 617{624, 2002. [212] Y. Y. Botros, E. S. Ebbini and J. L. Volakis, `Two-step hybrid virtual array ray (var) technique for focusing through the rib cage', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 45, no. 4, pp. 989{1000, 1998. [213] M. Tanter, M. Pernot, J.-F. Aubry, G. Montaldo, F. Marquet and M. Fink, `Compensating for bone interfaces and respiratory motion in highintensity focused ultrasound', International Journal of Hyperthermia, vol. 23, no. 2, pp. 141{151, 2007. [214] A. H. Chan, V. Y. Fujimoto, D. E. Moore, R. W. Martin and S. Vaezy, `An image-guided high intensity focused ultrasound device for uterine �broids treatment', Medical physics, vol. 29, no. 11, pp. 2611{2620, 2002. [215] L. Curiel, F. Chavrier, R. Souchon, A. Birer and J. Y. Chapelon, `1.5-D high intensity focused ultrasound array for non-invasive prostate cancer surgery', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 49, no. 2, pp. 231{242, 2002. 183 REFERENCES [216] S. C. Tang and G. T. Clement, `Acoustic standing wave suppression using randomized phase-shift-keying excitations', The Journal of the Acoustical Society of America, vol. 126, no. 4, pp. 1667{1670, 2009. [217] J.-F. Aubry, `Focusing ultrasound through bones: Past, current, and future transcostal and transskull strategies', The Journal of the Acous- tical Society of America, vol. 141, no. 5, pp. 3549{3549, 2017. [218] S. Concepts, H- transducer series �64 mm, http://bit.ly/2EOrwK6, accessed 23/02/2018. [219] P. Acoustics, HIFU transducers, https://www.acoustics.co.uk/ product/{HIFU}-transducers/, accessed 23/02/2018. [220] P. Davari, N. Ghasemi, F. Zare, P. O'shea and A. Ghosh, `Improving the e�ciency of high power piezoelectric transducers for industrial applications', IET Science, Measurement & Technology, vol. 6, no. 4, pp. 213{221, 2012. [221] S. Tamano, H. Jimbo, T. Azuma, S. Yoshizawa, K. Fujiwara, K. Itani and S.-I. Umemura, `Improvement of high-voltage staircase drive circuit waveform for high-intensity therapeutic ultrasound', Japanese Journal of Applied Physics, vol. 55, no. 7S1, 07KF17, 2016. [222] P. Kaczkowski, `Arbitrary waveform generation with the verasonics research ultrasound platform', Verasonics Inc., Tech. Rep., 2016. [223] G. K. Lewis Jr and W. L. Olbricht, `Design and characterization of a high-power ultrasound driver with ultralow-output impedance', Review of scienti�c instruments, vol. 80, no. 11, p. 114 704, 2009. [224] W. Wong, C. Christo�ersen, S. Pichardo and L. Curiel, `An integrated ultrasound transducer driver for HIFU applications', in Electrical and Computer Engineering (CCECE), 2013 26th Annual IEEE Canadian Conference on, IEEE, 2013, pp. 1{5. [225] K. Moro, S. Yoshizawa and S.-i. Umemura, `Staircase-voltage metal{ oxide{semiconductor �eld-e�ect transistor driver circuit for therapeutic ultrasound', Japanese Journal of Applied Physics, vol. 49, no. 7S, 07HF02, 2010. 184 REFERENCES [226] A. Berkovich, A. Bursian, K. Zaychenko and N. Petrishchev, `A highfrequency generator used in high-intensity focused ultrasound transducers for tissue ablation and vessel obliteration', Biomedical Engin- eering, vol. 51, no. 3, pp. 215{217, 2017. [227] D. M. Cowell, P. R. Smith and S. Freear, `Phase-inversion-based selective harmonic elimination (PI-SHE) in multi-level switched-mode toneand frequency-modulated excitation', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 60, no. 6, pp. 1084{1097, 2013. [228] S. Harput, M. Arif, J. McLaughlan, D. J. Cowell and S. Freear, `The e�ect of amplitude modulation on subharmonic imaging with chirp excitation', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 60, no. 12, pp. 2532{2544, 2013. [229] B. E. Treeby, J. Jaros, A. P. Rendell and B. Cox, `Modeling nonlinear ultrasound propagation in heterogeneous media with power law absorption using a k-space pseudospectral method', The Journal of the Acoustical Society of America, vol. 131, no. 6, pp. 4324{4336, 2012. [230] D. Nassiri, D. Nicholas and C. Hill, `Attenuation of ultrasound in skeletal muscle', Ultrasonics, vol. 17, no. 5, pp. 230{232, 1979. [231] W. L. Nyborg, `Heat generation by ultrasound in a relaxing medium', The Journal of the Acoustical Society of America, vol. 70, no. 2, pp. 310{ 312, 1981. doi: 10.1121/1.386778. eprint: https://doi.org/10. 1121/1.386778. [232] H. H. Pennes, `Analysis of tissue and arterial blood temperatures in the resting human forearm', Journal of applied physiology, vol. 1, no. 2, pp. 93{122, 1948. [233] S. A. Sapareto and W. C. Dewey, `Thermal dose determination in cancer therapy', International Journal of Radiation Oncology* Biology* Physics, vol. 10, no. 6, pp. 787{800, 1984. [234] P. S. Yarmolenko, E. J. Moon, C. Landon, A. Manzoor, D. W. Hochman, B. L. Viglianti and M. W. Dewhirst, `Thresholds for thermal damage to normal tissues: An update', International Journal of Hyperthermia, vol. 27, no. 4, pp. 320{343, 2011. 185 REFERENCES [235] J. McLaughlan, I. Rivens, T. Leighton and G. Ter Haar, `A study of bubble activity generated in ex vivo tissue by high intensity focused ultrasound', Ultrasound in medicine & biology, vol. 36, no. 8, pp. 1327{ 1344, 2010. [236] P. Lai, J. R. McLaughlan, A. B. Draudt, T. W. Murray, R. O. Cleveland and R. A. Roy, `Real-time monitoring of high-intensity focused ultrasound lesion formation using acousto-optic sensing', Ultrasound in medicine & biology, vol. 37, no. 2, pp. 239{252, 2011. [237] Y. Zhou, L. Zhai, R. Simmons and P. Zhong, `Measurement of high intensity focused ultrasound �elds by a �ber optic probe hydrophone', The Journal of the Acoustical Society of America, vol. 120, no. 2, pp. 676{ 685, 2006. [238] G. ter Haar, A. Shaw, S. Pye, B. Ward, F. Bottomley, R. Nolan and A.-M. Coady, `Guidance on reporting ultrasound exposure conditions for bio-e�ects studies', Ultrasound in Medicine and Biology, vol. 37, no. 2, pp. 177{183, 2011. [239] W. W. Elliott AC, Statistical analysis quick reference guidebook with SPSS examples. Sage Publications, 2007. [240] T. Leighton, The acoustic bubble. Academic press, 2012. [241] K. Hynynen, Impedance matching for ultrasound phased array elements, US Patent 9,387,515, Jul. 2016. [242] C. Hill, `Calibration of ultrasonic beams for bio-medical applications', Physics in Medicine & Biology, vol. 15, no. 2, p. 241, 1970. [243] J. R. McLaughlan, `An investigation into the use of cavitation for the optimisation of high intensity focused ultrasound (HIFU) treatments', PhD thesis, Institute of Cancer Research (University Of London), 2008."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.770048"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["1 U01 HL121838-01","EP/K029835/1","105615/Z/14/Z","RG170324"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/23017/1/Adams_CD_Electronic_PhD_2018.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this thesis is to utilise modern open-design ultrasound research platforms to develop new and advance several existing techniques that incorporate nonlinear phenomena. Acoustically, nonlinearity refers to changes in speed of sound, attenuation or elasticity that vary with frequency, temperature or pressure. These effects cannot be linearised by the wave equation and require fluid dynamics and elasticity equations to be fully understood. While this is a hindrance and source of error in many areas of ultrasound such as high-intensity focused ultrasound (HIFU) and medical imaging, nonlinearities do have uses in non-destructive guided wave (GW) testing. These effects are influenced greatly by the transducer surface pressure, and so precise control of the excitation is necessary to achieve the desired nonlinear effect, if any, in the medium. In this thesis, aided by the use of two new research platforms, several new ultrasound techniques were developed. It was shown the frequency content in the electrical waveform is pertinent and so distortion must be minimised. This requirement conflicts with several hardware limitations, however. Accordingly, a genetic algorithm was applied to find novel switched waveform designs. It was found to achieve a 2% granularity in amplitude control with harmonic reduction, where existing waveform designs could not produce any. This fine amplitude control is a requirement for array applications. Following this, a technique to control the direction of GWs without knowledge of the waveguide was devised. Recordings of a propagating GW, induced by the first element of an array transducer, were re-transmitted in a recursive fashion. The effect was that the transducer's transmissions constructively interfered with the transverse wave, causing most of the guided wave energy to travel in the direction of the transducer's spatial influence. Experimental results show a 34 dB enhancement in one direction compared with the other. GWs were then applied to bone for two purposes: for assessment of osteoporosis and for measurement of skull properties to assist transcranial therapy. It was shown that existing methods for obtaining dispersion curves are ineffectual due to limitations in the available sampling area. A signal processing scheme was devised to temporally align transverse dispersive waves so that beamforming style techniques could be applied to prove or disprove the existence of certain modes. The technique in combination with multiplication was applied to numerical, ex vivo and in vivo experiments. It was found to improve the contrast of the higher order modes. The technique could improve the reliability of osteoporosis diagnosis with ultrasound, but may also prove useful for acquiring dispersion images in NDT. Numerically the technique was shown to improve the S3 and A3 mode intensity by 6 dB and 13 dB respectively compared with an existing Fourier method. In skull, a relationship was found between the curved therapeutic array geometry and the delay profile necessary to form GWs in skull. Several numerical models were tested and it was shown that the thickness could be obtained from the group velocity. The estimated maximum error using this technique was 0.2 mm. Since the data is co-registered with the therapeutic elements, this method could be used to improve the accuracy of thermal treatments in the brain. Finally, the application of switched excitation for HIFU was considered. To improve on cost, efficiency and size, alternative excitation methods have the potential to replace the linear amplifier circuitry currently used in HIFU. In this final study, harmonic reduction pulse width modulation (HRPWM) was proposed as an algorithmic solution to the design of switched waveforms. Its appropriateness for HIFU was assessed by design of a high power 5 level unfiltered amplifier and subsequent thermal-only lesioning of ex vivo chicken breast. HRPWM produced symmetric, thermal-only lesions that were the same size as their linear amplifier equivalents (p > 0.05). These results demonstrate that HRPWM can minimise HIFU drive circuity size without the need for filters to remove harmonics or adjustable power supplies to achieve array apodisation. Overall it has been shown in this thesis that precise control of the nonlinear wave phenomena can be afforded when using open-platform ultrasound research hardware. The methods described within may reduce the cost and increase the efficacy of future commercial systems."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["The Generation and Control of Ultrasonic Waves in Nonlinear Media"]}]}],"canonical_facts":{"dc:contributor.advisor":["Freear, Steven","McLaughlan, James Ross","Cowell, David"],"dc:contributor.sponsor":["NHBLI","EPSRC","Wellcome Trust","Royal Society"],"dc:creator":["Adams, Christopher"],"dc:date":["2018-11"],"dc:date.issued":["2018-11"],"dc:description.abstract":["The objective of this thesis is to utilise modern open-design ultrasound research platforms to develop new and advance several existing techniques that incorporate nonlinear phenomena. Acoustically, nonlinearity refers to changes in speed of sound, attenuation or elasticity that vary with frequency, temperature or pressure. These effects cannot be linearised by the wave equation and require fluid dynamics and elasticity equations to be fully understood. While this is a hindrance and source of error in many areas of ultrasound such as high-intensity focused ultrasound (HIFU) and medical imaging, nonlinearities do have uses in non-destructive guided wave (GW) testing. These effects are influenced greatly by the transducer surface pressure, and so precise control of the excitation is necessary to achieve the desired nonlinear effect, if any, in the medium. In this thesis, aided by the use of two new research platforms, several new ultrasound techniques were developed. It was shown the frequency content in the electrical waveform is pertinent and so distortion must be minimised. This requirement conflicts with several hardware limitations, however. Accordingly, a genetic algorithm was applied to find novel switched waveform designs. It was found to achieve a 2% granularity in amplitude control with harmonic reduction, where existing waveform designs could not produce any. This fine amplitude control is a requirement for array applications. Following this, a technique to control the direction of GWs without knowledge of the waveguide was devised. Recordings of a propagating GW, induced by the first element of an array transducer, were re-transmitted in a recursive fashion. The effect was that the transducer's transmissions constructively interfered with the transverse wave, causing most of the guided wave energy to travel in the direction of the transducer's spatial influence. Experimental results show a 34 dB enhancement in one direction compared with the other. GWs were then applied to bone for two purposes: for assessment of osteoporosis and for measurement of skull properties to assist transcranial therapy. It was shown that existing methods for obtaining dispersion curves are ineffectual due to limitations in the available sampling area. A signal processing scheme was devised to temporally align transverse dispersive waves so that beamforming style techniques could be applied to prove or disprove the existence of certain modes. The technique in combination with multiplication was applied to numerical, ex vivo and in vivo experiments. It was found to improve the contrast of the higher order modes. The technique could improve the reliability of osteoporosis diagnosis with ultrasound, but may also prove useful for acquiring dispersion images in NDT. Numerically the technique was shown to improve the S3 and A3 mode intensity by 6 dB and 13 dB respectively compared with an existing Fourier method. In skull, a relationship was found between the curved therapeutic array geometry and the delay profile necessary to form GWs in skull. Several numerical models were tested and it was shown that the thickness could be obtained from the group velocity. The estimated maximum error using this technique was 0.2 mm. Since the data is co-registered with the therapeutic elements, this method could be used to improve the accuracy of thermal treatments in the brain. Finally, the application of switched excitation for HIFU was considered. To improve on cost, efficiency and size, alternative excitation methods have the potential to replace the linear amplifier circuitry currently used in HIFU. In this final study, harmonic reduction pulse width modulation (HRPWM) was proposed as an algorithmic solution to the design of switched waveforms. Its appropriateness for HIFU was assessed by design of a high power 5 level unfiltered amplifier and subsequent thermal-only lesioning of ex vivo chicken breast. HRPWM produced symmetric, thermal-only lesions that were the same size as their linear amplifier equivalents (p > 0.05). These results demonstrate that HRPWM can minimise HIFU drive circuity size without the need for filters to remove harmonics or adjustable power supplies to achieve array apodisation. Overall it has been shown in this thesis that precise control of the nonlinear wave phenomena can be afforded when using open-platform ultrasound research hardware. The methods described within may reduce the cost and increase the efficacy of future commercial systems."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.770048"],"dc:identifier.grantnumber":["1 U01 HL121838-01","EP/K029835/1","105615/Z/14/Z","RG170324"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/23017/1/Adams_CD_Electronic_PhD_2018.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["School of Electronic & Electrical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/23017/"],"dc:relation.references":["C. Adams, D. M. Cowell, L. Nie, J. R. McLaughlan and S. Freear, `A miniature HIFU excitation scheme to eliminate switching-induced grating lobes and nullify hard tissue attenuation', in Ultrasonics Symposium (IUS), 2017 IEEE International, IEEE, 2017, pp. 1{4. [2] D. Cowell, T. Carpenter, P. Smith, C. Adams, S. Harput and S. Freear, `Modi�ed harmonic reduction pulse width modulation (mHRPWM) for switched excitation of resonant HIFU transducers', in Ultrasonics Sym- posium (IUS), 2018 IEEE International, IEEE, 2018, pp. 1{4. [3] C. Adams, S. Harput, D. Cowell, T. M. Carpenter, D. M. Charutz and S. Freear, `An adaptive array excitation scheme for the unidirectional enhancement of guided waves', IEEE transactions on ultrasonics, fer- roelectrics, and frequency control, vol. 64, no. 2, pp. 441{451, 2017. [4] C. Adams, S. Harput, D. Cowell, S. Freear and D. Charutz, `Specimenagnostic guided wave inspection using recursive feedback', in IEEE In- ternational Ultrasonics Symposium (IUS), IEEE, 2016. [5] C. Adams, S. Harput, D. Cowell and S. Freear, `A phase velocity �lter for the measurement of Lamb wave dispersion', in IEEE International Ultrasonics Symposium (IUS), IEEE, 2016. [6] C. Adams, J. McLaughlan, L. Nie and S. Freear, `Excitation and acquisition of cranial guided waves using a concave array transducer', in Proceedings of Meetings on Acoustics 173EAA, ASA, vol. 30, 2017, p. 055 003. 159 REFERENCES [7] C. Adams, T. M. Carpenter, D. Cowell, S. Freear and J. R. McLaughlan, `HIFU drive system miniaturisation using harmonic reduced pulse width modulation', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2018. [8] T. M. Carpenter, C. Adams, S. Freear, D. Cowell and J. McLaughlan, Five Level Switched High Intensity Focused Ultrasound Driver Design, Jul. 2018. [9] S. R. Ansari, `On the physical researches of al~biruni', Indian Journal of History of Science, vol. 11, 1975. [10] C. B. Boyer and U. C. Merzbach, A history of mathematics. John Wiley & Sons, 2011. [11] G. Galilei, Galileo: Two new sciences (translation by stillman drake of galileo's 1638 discourses and mathematical demonstrations concerning two new sciences), 1974. [12] J. W. S. B. Rayleigh, The theory of sound. Macmillan, 1896, vol. 2. [13] H. Lamb, The dynamical theory of sound. Courier Corporation, 2004. [14] J. Rose, `Recent advances in guided wave NDE', 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium, 1995. doi: 10. 1109/ultsym.1995.495679. [15] G. Ter Haar, `Therapeutic applications of ultrasound', Progress in bio- physics and molecular biology, vol. 93, no. 1, pp. 111{129, 2007. [16] V. A. Khokhlova, M. R. Bailey, J. A. Reed, B. W. Cunitz, P. J. Kaczkowski and L. A. Crum, `E�ects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom', The Journal of the Acoustical Society of America, vol. 119, no. 3, pp. 1834{1848, 2006. [17] S. Harput, Use of chirps in medical ultrasound imaging. University of Leeds, 2012. 160 REFERENCES [18] E. Boni, C. Alfred, S. Freear, J. A. Jensen and P. Tortoli, `Ultrasound open platforms for next-generation imaging technique development', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Con- trol, 2018. [19] A. Marzo, T. Corkett and B. W. Drinkwater, `Ultraino: An open phasedarray system for narrowband airborne ultrasound transmission', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 65, no. 1, pp. 102{111, 2018. [20] E. Boni, L. Bassi, A. Dallai, F. Guidi, V. Meacci, A. Ramalli, S. Ricci and P. Tortoli, `ULA-OP 256: A 256-channel open scanner for development and real-time implementation of new ultrasound methods', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 63, no. 10, pp. 1488{1495, 2016. [21] D. Cowell, T. Carpenter, P. Smith, C. Adams, S. Harput and S. Freear, `Performance of switched mode arbitrary excitation using harmonic reduction pulse width modulation (HRPWM) in array imaging applications', in Ultrasonics Symposium (IUS), 2016 IEEE International, IEEE, 2016, pp. 1{4. [22] L. Nie, S. Harput, D. M. Cowell, T. Carpenter, J. R. McLaughlan and S. Freear, `Combining acoustic trapping with plane wave imaging for localized microbubble accumulation in large vessels', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2018. [23] C. Adams, J. R. McLaughlan, L. Nie, D. Cowell, T. Carpenter and S. Freear, `Excitation of leaky Lamb waves in cranial bone using a phased array transducer in a concave therapeutic con�guration', The Journal of the Acoustical Society of America, 2017. [24] R. Krimholtz, D. A. Leedom and G. L. Matthaei, `New equivalent circuits for elementary piezoelectric transducers', Electronics Letters, vol. 6, no. 13, pp. 398{399, 1970. [25] M. O'Donnell, `Coded excitation system for improving the penetration of real-time phased-array imaging systems', IEEE transactions on ul- 161 REFERENCES trasonics, ferroelectrics, and frequency control, vol. 39, no. 3, pp. 341{ 351, 1992. [26] S. Tang, S. Hui and H. Chung, `A naturally soft-switched high-frequency gate drive circuit for power MOSFETs/IGBTs', in Power Electronics and Drive Systems, 1999. PEDS'99. Proceedings of the IEEE 1999 In- ternational Conference on, IEEE, vol. 1, 1999, pp. 246{252. [27] M. M. El-Desouki and K. Hynynen, `Driving circuitry for focused ultrasound noninvasive surgery and drug delivery applications', Sensors, vol. 11, no. 1, pp. 539{556, 2011. [28] S. D. Kee, `The class E/F family of harmonic-tuned switching power ampli�ers', PhD thesis, California Institute of Technology, 2002. [29] R. Seip, W. Chen, J. Tavakkoli, L. Frizzell and N. Sanghvi, `Highintensity focused ultrasound (HIFU) phased arrays: Recent developments in transrectal transducers and driving electronics design', in Proc. 3rd Int. Symp. on Therapeutic Ultrasound, 2003, pp. 423{428. [30] C. Christo�ersen, W. Wong, S. Pichardo, G. Togtema and L. Curiel, `Class-DE ultrasound transducer driver for HIFU therapy', IEEE trans- actions on biomedical circuits and systems, vol. 10, no. 2, pp. 375{382, 2016. [31] E. Gaalaas, `Class D audio ampli�ers: What, why, and how', Analog Devices Inc., Tech. Rep., 2006. [32] S. C. Tang and G. T. Clement, `A harmonic cancellation technique for an ultrasound transducer excited by a switched-mode power converter', in Ultrasonics Symposium, 2008. IUS 2008. IEEE, IEEE, 2008, pp. 2076{2079. [33] D. Cowell, P. Smith, S. Harput, J. McLaughlan and S. Freear, `Nonlinear harmonic reduction pulse width modulation (HRPWM) for the arbitrary control of transducer-integrated switched excitation electronics', 2014 IEEE International Ultrasonics Symposium, 2014. doi: 10. 1109/ultsym.2014.0198. [34] H. Meire and P. Farrant, Basic ultrasound, 1995. 162 REFERENCES [35] B. W. Drinkwater and P. D. Wilcox, `Ultrasonic arrays for non-destructive evaluation: A review', NDT & E International, vol. 39, no. 7, pp. 525{ 541, 2006, issn: 0963-8695. doi: 10.1016/j.ndteint.2006.03.006. [36] OlympusNDT, Phased array tutorial, 2018. [37] F. Xiaobing and H. Kullervo, `Control of the necrosed tissue volume during noninvasive ultrasound surgery using a 16-element phased array', Medical Physics, vol. 22, no. 3, pp. 297{306, doi: 10.1118/1.597603. eprint: https : / / aapm . onlinelibrary . wiley . com / doi / pdf / 10 . 1118/1.597603. [38] R. S. Cobbold, Foundations of biomedical ultrasound. Oxford University Press, 2006. [39] C. P. Karunakaran and M. L. Oelze, `Amplitude modulated chirp excitation to reduce grating lobes and maintain ultrasound intensity at the focus of an array', Ultrasonics, vol. 53, no. 7, pp. 1293{1303, 2013. [40] E. S. Ebbini, H. Yao and A. Shrestha, `Dual-mode ultrasound phased arrays for image-guided surgery', Ultrasonic Imaging, vol. 28, no. 2, pp. 65{82, 2006, PMID: 17094688. doi: 10.1177/016173460602800201. eprint: http://dx.doi.org/10.1177/016173460602800201. [41] J. A. Jensen, `Field: A program for simulating ultrasound systems', in 10TH NORDICBALTIC CONFERENCE ON BIOMEDICAL IMA- GING, VOL. 4, SUPPLEMENT 1, PART 1: 351{353, Citeseer, 1996. [42] J. Civale, R. Clarke, I. Rivens and G. Ter Haar, `The use of a segmented transducer for rib sparing in HIFU treatments', Ultrasound in medicine & biology, vol. 32, no. 11, pp. 1753{1761, 2006. [43] F. J. �Alvarez and R. Kuc, `Dispersion relation for air via Kramers- Kronig analysis', The Journal of the Acoustical Society of America, vol. 124, no. 2, EL57{EL61, 2008. [44] R. d. L. Kronig, `On the theory of dispersion of x-rays', Josa, vol. 12, no. 6, pp. 547{557, 1926. [45] J. S. Toll, `Causality and the dispersion relation: Logical foundations', Physical review, vol. 104, no. 6, p. 1760, 1956. 163 REFERENCES [46] I. A. Viktorov, Rayleigh and Lamb waves: physical theory and applica- tions. Plenum press, 1970. [47] N. Bochud, Q. Vallet, J.-G. Minonzio and P. Laugier, `Predicting bone strength with ultrasonic guided waves', Scienti�c Reports, vol. 7, p. 43 628, 2017. [48] A. P. Duryea, T. L. Hall, A. D. Maxwell, Z. Xu, C. A. Cain and W. W. Roberts, `Histotripsy erosion of model urinary calculi', Journal of end- ourology, vol. 25, no. 2, pp. 341{344, 2011. [49] B. E. Treeby and B. T. Cox, `K-wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave �elds', Journal of bio- medical optics, vol. 15, no. 2, pp. 021 314{021 314, 2010. [50] J. E. Lingeman, J. A. McAteer, E. Gnessin and A. P. Evan, `Shock wave lithotripsy: Advances in technology and technique', Nature Re- views Urology, vol. 6, no. 12, p. 660, 2009. [51] F. A. Duck, Physical properties of tissues: a comprehensive reference book. Academic press, 2013. [52] M. A. O'Reilly, R. M. Jones and K. Hynynen, `Three-dimensional transcranial ultrasound imaging of microbubble clouds using a sparse hemispherical array', IEEE Transactions on Biomedical Engineering, vol. 61, no. 4, pp. 1285{1294, 2014. [53] D. A. Coley, An introduction to genetic algorithms for scientists and engineers. World Scienti�c Publishing Company, 1999. [54] H. Aytug and G. J. Koehler, `New stopping criterion for genetic algorithms', European Journal of Operational Research, vol. 126, no. 3, pp. 662{674, 2000. [55] S. Baluja and R. Caruana, `Removing the genetics from the standard genetic algorithm', in Machine Learning Proceedings 1995, Elsevier, 1995, pp. 38{46. [56] M. Srinivas and L. M. Patnaik, `Genetic algorithms: A survey', com- puter, vol. 27, no. 6, pp. 17{26, 1994. 164 REFERENCES [57] R. H. Silverman, `High-resolution ultrasound imaging of the eye - a review', Clinical & experimental ophthalmology, vol. 37, no. 1, pp. 54{ 67, 2009. [58] C. Fei, C. T. Chiu, X. Chen, Z. Chen, J. Ma, B. Zhu, K. K. Shung and Q. Zhou, `Ultrahigh frequency (100 MHz-300 MHz) ultrasonic transducers for optical resolution medical imagining', Scienti�c reports, vol. 6, p. 28 360, 2016. [59] K. Xu, D. Ta, B. Hu, P. Laugier and W. Wang, `Wideband dispersion reversal of Lamb waves', IEEE Transactions on Ultrasonics, Ferroelec- trics, and Frequency Control, vol. 61, no. 6, pp. 997{1005, Jun. 2014, issn: 0885-3010. doi: 10.1109/TUFFC.2014.2995. [60] M. Lowe, D. Alleyne and P. Cawley, `Defect detection in pipes using guided waves', Ultrasonics, vol. 36, no. 1{5, pp. 147{154, 1998, Ultrasonics International 1997, issn: 0041-624X. doi: 10.1016/S0041- 624X(97)00038-3. [61] J. Davies and P. Cawley, `The application of synthetic focusing for imaging crack-like defects in pipelines using guided waves', Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on, vol. 56, no. 4, pp. 759{771, 2009. [62] I. Pelivanov, A. Shtokolov, C.-w. Wei and M. O'donnell, `A 1 kHz ascan rate pump-probe laser-ultrasound system for robust inspection of composites', Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on, vol. 62, no. 9, pp. 1696{1703, 2015. doi: 10.1109/ TUFFC.2015.007110. [63] A. K. Edwards, S. Savage, P. L. Hungler and T. W. Krause, `Examination of f/a-18 honeycomb composite rudders for disbond due to water using through-transmission ultrasonics', Ultrasound, vol. 66, no. 2, 2011. doi: 10.5755/j01.u.66.2.529. [64] J. L. Rose, `A baseline and vision of ultrasonic guided wave inspection potential', Journal of Pressure Vessel Technology, vol. 124, no. 3, p. 273, 2002. doi: 10.1115/1.1491272. 165 REFERENCES [65] T. E. Michaels, J. E. Michaels and M. Ruzzene, `Frequency-wavenumber domain analysis of guided wave�elds', Ultrasonics, vol. 51, no. 4, pp. 452{ 466, 2011, issn: 0041-624X. doi: 10.1016/j.ultras.2010.11.011. [66] P. Cawley and D. Alleyne, `The use of Lamb waves for the long range inspection of large structures', Ultrasonics, vol. 34, no. 2{5, pp. 287{290, 1996, Proceedings of Ultrasonics International 1995, issn: 0041-624X. doi: 10.1016/0041-624X(96)00024-8. [67] D. N. Alleyne and P. Cawley, `Optimization of Lamb wave inspection techniques', Ndt & E International, vol. 25, no. 1, pp. 11{22, 1992. [68] P. D. Wilcox, M. J. S. Lowe and P. Cawley, `Mode and transducer selection for long range Lamb wave inspection', Journal of Intelligent Material Systems and Structures, vol. 12, no. 8, pp. 553{565, 2001. doi: 10.1177/10453890122145348. eprint: http://jim.sagepub.com/ content/12/8/553.full.pdf+html. [69] S. Fateri, P. S. Lowe, B. Engineer and N. V. Boulgouris, `Investigation of ultrasonic guided waves interacting with piezoelectric transducers', IEEE Sensors Journal, vol. 15, no. 8, pp. 4319{4328, 2015. [70] A. Croxford, P. Wilcox, B. Drinkwater and G. Konstantinidis, `Strategies for guided-wave structural health monitoring', Proceedings of the Royal Society of London A: Mathematical, Physical and Engineering Sciences, vol. 463, no. 2087, pp. 2961{2981, 2007, issn: 1364-5021. doi: 10.1098/ rspa.2007.0048. eprint: http://rspa.royalsocietypublishing. org/content/463/2087/2961.full.pdf. [71] B. Ren and C. J. Lissenden, `Pvdf multielement Lamb wave sensor for structural health monitoring', IEEE transactions on ultrasonics, ferro- electrics, and frequency control, vol. 63, no. 1, pp. 178{185, 2016. [72] J.-B. Ihn and F.-K. Chang, `Detection and monitoring of hidden fatigue crack growth using a built-in piezoelectric sensor/actuator network: Ii. validation using riveted joints and repair patches', Smart Mater. Struct., vol. 13, no. 3, pp. 621{630, 2004. doi: 10.1088/0964-1726/13/3/021. 166 REFERENCES [73] A. Perelli, L. De Marchi, A. Marzani and N. Speciale, `Acoustic emission localization in plates with dispersion and reverberations using sparse PZT sensors in passive mode', Smart Mater. Struct., vol. 21, no. 2, p. 025 010, 2012. doi: 10.1088/0964-1726/21/2/025010. [74] E. Baravelli, M. Senesi, M. Ruzzene and L. De Marchi, `Fabrication and characterization of a wavenumber-spiral frequency-steerable acoustic transducer for source localization in plate structures', IEEE Trans- actions on Instrumentation and Measurement, vol. 62, no. 8, pp. 2197{ 2204, 2013. doi: 10.1109/tim.2013.2255992. [75] A. Mahmoud, D. Cortes, A. Abaza, H. Ammar, M. Hazey, P. Ngan, R. Crout and O. Mukdadi, `Noninvasive assessment of human jawbone using ultrasonic guided waves', IEEE Transactions on Ultrasonics, Fer- roelectrics, and Frequency Control, vol. 55, no. 6, pp. 1316{1327, Jun. 2008, issn: 0885-3010. doi: 10.1109/TUFFC.2008.794. [76] V. C. Protopappas, D. I. Fotiadis and K. N. Malizos, `Guided ultrasound wave propagation in intact and healing long bones', Ultrasound in medicine & biology, vol. 32, no. 5, pp. 693{708, 2006. [77] J. Foiret, J. G. Minonzio, C. Chappard, M. Talmant and P. Laugier, `Combined estimation of thickness and velocities using ultrasound guided waves: A pioneering study on in vitro cortical bone samples', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 61, no. 9, pp. 1478{1488, Sep. 2014, issn: 0885-3010. doi: 10.1109/TUFFC. 2014.3062. [78] A. Mahmoud, D. Cortes, A. Abaza, H. Ammar, O. Mukdadi, M. Hazey, P. Ngan and R. Crout, `P5A-10 Assessment of human jawbone using ultrasonic guided wave: In vitro study', in Ultrasonics Symposium, 2007. IEEE, Oct. 2007, pp. 2183{2186. doi: 10.1109/ULTSYM.2007.549. [79] P. Moilanen, P. H. Nicholson, V. Kilappa, S. Cheng and J. Timonen, `Assessment of the cortical bone thickness using ultrasonic guided waves: Modelling and in vitro study', Ultrasound in medicine & biology, vol. 33, no. 2, pp. 254{262, 2007. 167 REFERENCES [80] E. Maksuti, E. Widman, D. Larsson, M. W. Urban, M. Larsson and A. Bj�allmark, `Arterial sti�ness estimation by shear wave elastography: Validation in phantoms with mechanical testing', Ultrasound in Medi- cine and Biology, vol. 42, no. 1, pp. 308{321, Mar. 2016, issn: 0301-5629. doi: 10.1016/j.ultrasmedbio.2015.08.012. [81] M. J. S. Lowe, R. E. Challis and C. W. Chan, `The transmission of Lamb waves across adhesively bonded lap joints', The Journal of the Acoustical Society of America, vol. 107, no. 3, pp. 1333{1345, 2000. doi: 10.1121/1.428420. [82] E. Moreno and P. Acevedo, `Thickness measurement in composite materials using Lamb waves', Ultrasonics, vol. 35, no. 8, pp. 581{586, 1998. [83] W. Zhu and J. L. Rose, `Lamb wave generation and reception with timedelay periodic linear arrays: A bem simulation and experimental study', Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on, vol. 46, no. 3, pp. 654{664, 1999. [84] J. L. Rose, Ultrasonic Waves in Solid Media. Cambridge University Press, 1999. [85] V. Dayal and V. K. Kinra, `Leaky Lamb waves in an anisotropic plate. i: An exact solution and experiments', The Journal of the Acoustical Society of America, vol. 85, no. 6, pp. 2268{2276, 1989. doi: 10.1121/ 1.397772. [86] J. Rose, `Guided wave nuances for ultrasonic nondestructive evaluation', IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Con- trol, vol. 47, no. 3, pp. 575{583, 2000. doi: 10.1109/58.842044. [87] P. Khalili and P. Cawley, `Excitation of single-mode Lamb waves at high-frequency-thickness products', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 63, no. 2, pp. 303{312, 2016. [88] P. Fromme, P. Wilcox, M. J. S. Lowe and P. Cawley, `On the development and testing of a guided ultrasonic wave array for structural integrity monitoring', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 53, no. 4, pp. 777{785, Apr. 2006, issn: 0885-3010. doi: 10.1109/TUFFC.2006.1621505. 168 REFERENCES [89] D. Alleyne and P. Cawley, `A two-dimensional fourier transform method for the measurement of propagating multimode signals', The Journal of the Acoustical Society of America, vol. 89, no. 3, pp. 1159{1168, 1991. [90] D. N. Alleyne and P. Cawley, `The interaction of Lamb waves with defects', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 39, no. 3, pp. 381{397, 1992. [91] M. Harb and F. Yuan, `Non-contact ultrasonic technique for Lamb wave characterization in composite plates', Ultrasonics, vol. 64, pp. 162{169, 2016. [92] Y. Cho and J. L. Rose, `A boundary element solution for a mode conversion study on the edge re ection of Lamb waves', The Journal of the Acoustical Society of America, vol. 99, no. 4, pp. 2097{2109, 1996. [93] O. Asfar, B. Morvan and J.-L. Izbicki, `Three-mode coupling of symmetric and antisymmetric Lamb waves in plates with �nite corrugations', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 62, no. 3, pp. 524{530, 2015. [94] P. S. Tua, S. T. Quek and Q. Wang, `Detection of cracks in plates using piezo-actuated Lamb waves', Smart Materials and Structures, vol. 13, no. 4, p. 643, 2004. [95] J. E. Michaels, A. J. Croxford and P. D. Wilcox, `Imaging algorithms for locating damage via in situ ultrasonic sensors', in Sensors Applications Symposium, 2008. SAS 2008. IEEE, Feb. 2008, pp. 63{67. [96] S. Fu, L. Shi, Y. Zhou and J. Cai, `Dispersion compensation in Lamb wave defect detection with step-pulse excitation and warped frequency transform', IEEE Transactions on Ultrasonics, Ferroelectrics, and Fre- quency Control, vol. 61, no. 12, pp. 2075{2088, Dec. 2014, issn: 0885- 3010. doi: 10.1109/TUFFC.2014.006606. [97] X. Chen, J. E. Michaels and T. E. Michaels, `A methodology for estimating guided wave scattering patterns from sparse transducer array measurements', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 62, no. 1, pp. 208{219, 2015. 169 REFERENCES [98] Y. Lu and J. Saniie, `Adaptive �ltering and fractional Fourier transform for ultrasonic signal processsing and aw detection', in Ultrasonics Sym- posium (IUS), 2014 IEEE International, Sep. 2014, pp. 1932{1935. doi: 10.1109/ULTSYM.2014.0480. [99] G. Konstantinidis, P. D. Wilcox and B. W. Drinkwater, `An investigation into the temperature stability of a guided wave structural health monitoring system using permanently attached sensors', IEEE Sensors Journal, vol. 7, no. 5, pp. 905{912, May 2007, issn: 1530-437X. doi: 10.1109/JSEN.2007.894908. [100] J. Bingham and M. Hinders, `Lamb wave detection of delaminations in large diameter pipe coatings', Open Acoustics Journal, vol. 2, pp. 75{ 86, 2009. [101] K. K. Shung, M. B. Smith and B. M. W. Tsui, Principles of medical imaging. Academic Press, 1992. [102] L. Moreau, B. W. Drinkwater and P. D. Wilcox, `Ultrasonic imaging algorithms with limited transmission cycles for rapid nondestructive evaluation', IEEE Transactions on Ultrasonics, Ferroelectrics, and Fre- quency Control, vol. 56, no. 9, pp. 1932{1944, Sep. 2009, issn: 0885- 3010. doi: 10.1109/TUFFC.2009.1269. [103] J. Zhang, B. W. Drinkwater, P. D. Wilcox and A. J. Hunter, `Defect detection using ultrasonic arrays: The multi-mode total focusing method', NDT & E International, vol. 43, no. 2, pp. 123{133, 2010, issn: 0963- 8695. doi: 10.1016/j.ndteint.2009.10.001. [104] C. F. Vasile, `Periodic magnet unidirectional transducer', 4 232 557, Nov. 1980. [105] J. Li and J. L. Rose, `Implementing guided wave mode control by use of a phased transducer array', IEEE transactions on ultrasonics, ferro- electrics, and frequency control, vol. 48, no. 3, pp. 761{768, 2001. [106] D. M. Charutz, E. Mor, S. Harput, D. M. J. Cowell, P. R. Smith and S. Freear, `Guided wave enhancement phased array beamforming scheme using recursive feedback', in 2013 IEEE International Ultrasonics Sym- 170 REFERENCES posium (IUS), Jul. 2013, pp. 166{169. doi: 10.1109/ULTSYM.2013. 0043. [107] A. Gachagan, G. Hayward, A. McNab, P. Reynolds, S. G. Pierce, W. R. Philp and B. Culshaw, `Generation and reception of ultrasonic guided waves in composite plates using conformable piezoelectric transmitters and optical-�ber detectors', IEEE Transactions on Ultrasonics, Ferro- electrics, and Frequency Control, vol. 46, no. 1, pp. 72{81, Jan. 1999, issn: 0885-3010. doi: 10.1109/58.741426. [108] I. Bartoli, A. Marzani, F. L. di Scalea and E. Viola, `Modeling wave propagation in damped waveguides of arbitrary cross-section', Journal of Sound and Vibration, vol. 295, no. 3{5, pp. 685{707, 2006. [109] P. Bocchini, A. Marzani and E. Viola, `Graphical user interface for guided acoustic waves', Journal of Computing in Civil Engineering, vol. 25, no. 3, pp. 202{210, 2011. doi: 10 . 1061 / (ASCE ) CP . 1943 - 5487.0000081. [110] P. N. Marty, N. Desai and J. Andersson, `NDT of kissing bond in aeronautical structures', in 16th World Conference on NDT, 2004. [111] N. Guo and P. Cawley, `The interaction of Lamb waves with delaminations in composite laminates', The Journal of the Acoustical Society of America, vol. 94, no. 4, pp. 2240{2246, 1993. [112] F. L. di Scalea, P. Rizzo and A. Marzani, `Propagation of ultrasonic guided waves in lap-shear adhesive joints: Case of incident a0 Lamb wave', The Journal of the Acoustical Society of America, vol. 115, no. 1, pp. 146{156, 2004. [113] J. B. Harley and J. M. Moura, `Data-driven and calibration-free Lamb wave source localization with sparse sensor arrays', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 62, no. 8, pp. 1516{ 1529, 2015. [114] S. E. Burrows, B. Dutton and S. Dixon, `Laser generation of Lamb waves for defect detection: Experimental methods and �nite element modeling', IEEE Transactions on Ultrasonics, Ferroelectrics, and Fre- 171 REFERENCES quency Control, vol. 59, no. 1, pp. 82{89, Jan. 2012, issn: 0885-3010. doi: 10.1109/TUFFC.2012.2158. [115] R. Levine and J. Michaels, `Block-sparse reconstruction and imaging for Lamb wave structural health monitoring', IEEE Transactions on Ultra- sonics, Ferroelectrics, and Frequency Control, vol. 61, no. 6, pp. 1006{ 1015, Jun. 2014, issn: 0885-3010. doi: 10.1109/TUFFC.2014.2996. [116] J. Hall and J. Michaels, `Minimum variance ultrasonic imaging applied to an in situ sparse guided wave array', IEEE Transactions on Ultra- sonics, Ferroelectrics, and Frequency Control, vol. 57, no. 10, pp. 2311{ 2323, Oct. 2010, issn: 0885-3010. doi: 10.1109/TUFFC.2010.1692. [117] A. Gachagan, P. Reynolds, G. Hayward and A. McNab, `Construction and evaluation of a new generation of exible ultrasonic transducers', in Ultrasonics Symposium, 1996. Proceedings., 1996 IEEE, vol. 2, Nov. 1996, pp. 853{8562. doi: 10.1109/ULTSYM.1996.584127. [118] B. Hailu, G. Hayward, A. Gachagan, A. McNab and R. Farlow, `Comparison of di�erent piezoelectric materials for the design of embedded transducers for structural health monitoring applications', in Ultrason- ics Symposium, 2000 IEEE, vol. 2, Oct. 2000, pp. 1009{10 122. doi: 10.1109/ULTSYM.2000.921495. [119] A. Gachagan, G. Hayward and R. Banks, `A exible piezoelectric transducer design for e�cient generation and reception of ultrasonic Lamb waves', IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 52, no. 7, pp. 1175{1182, Jul. 2005, issn: 0885-3010. doi: 10.1109/TUFFC.2005.1504004. [120] P. Marin-Franch, S. Cochran and K. Kirk, `Progress towards ultrasound applications of new single crystal materials', Journal of Materials Sci- ence: Materials in Electronics, vol. 15, no. 11, pp. 715{720, 2004, issn: 1573-482X. doi: 10.1023/B:JMSE.0000043418.10953.38. [121] M. Castaings and P. Cawley, `The generation, propagation, and detection of Lamb waves in plates using air-coupled ultrasonic transducers', The Journal of the Acoustical Society of America, vol. 100, no. 5, pp. 3070{3077, 1996. doi: 10.1121/1.417193. 172 REFERENCES [122] J. E. Michaels, S. J. Lee, A. J. Croxford and P. D. Wilcox, `Chirp excitation of ultrasonic guided waves', Ultrasonics, vol. 53, no. 1, pp. 265{ 270, 2013, issn: 0041-624X. doi: 10.1016/j.ultras.2012.06.010. [123] P. Augat and S. Schorlemmer, `The role of cortical bone and its microstructure in bone strength', Age and ageing, vol. 35, no. suppl 2, pp. ii27{ii31, 2006. [124] S. Bernard, J. Schneider, P. Varga, P. Laugier, K. Raum and Q. Grimal, `Elasticity-density and viscoelasticity-density relationships at the tibia mid-diaphysis assessed from resonant ultrasound spectroscopy measurements', Biomechanics and modeling in mechanobiology, vol. 15, no. 1, pp. 97{109, 2016. [125] Q. Grimal, K. Raum, A. Gerisch and P. Laugier, `A determination of the minimum sizes of representative volume elements for the prediction of cortical bone elastic properties', Biomechanics and Modeling in Mechanobiology, vol. 10, no. 6, pp. 925{937, 2011, issn: 1617-7940. doi: 10.1007/s10237-010-0284-9. [126] P. Droin, G. Berger and P. Laugier, `Velocity dispersion of acoustic waves in cancellous bone', IEEE transactions on ultrasonics, ferroelec- trics, and frequency control, vol. 45, no. 3, pp. 581{592, 1998. [127] N. Bochud, J.-G. Minonzio, Q. Vallet and P. Laugier, `An anisotropic bilayer model to gain insight into in-vivo guided wave measurements', in Ultrasonic Characterization of Bone (ESUCB), 2015 6th European Symposium on, IEEE, 2015, pp. 1{4. [128] P. H. Nicholson, P. Moilanen, T. K�arkk�ainen, J. Timonen and S. Cheng, `Guided ultrasonic waves in long bones: Modelling, experiment and in vivo application', Physiological measurement, vol. 23, no. 4, p. 755, 2002. [129] C. Baron, M. Talmant and P. Laugier, `E�ect of porosity on e�ective diagonal sti�ness coe�cients (CII) and elastic anisotropy of cortical bone at 1 MHz: A �nite-di�erence time domain study', The Journal of the Acoustical Society of America, vol. 122, no. 3, pp. 1810{1817, 2007. 173 REFERENCES [130] J. Y. Rho, R. B. Ashman and C. H. Turner, `Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements', Journal of biomechanics, vol. 26, no. 2, pp. 111{119, 1993. [131] P. Moilanen, `Ultrasonic guided waves in bone', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 55, no. 6, 2008. [132] P. Moilanen, M. Talmant, V. Kilappa, P. Nicholson, S. Cheng, J. Timonen and P. Laugier, `Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in human radius', The Journal of the Acoustical Society of America, vol. 124, no. 4, pp. 2364{2373, 2008. [133] E. Bossy, M. Talmant, M. Defontaine, F. Patat and P. Laugier, `Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: A validation on test materials', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 51, no. 1, pp. 71{79, 2004. [134] C. W. Connor and K. Hynynen, `Patterns of thermal deposition in the skull during transcranial focused ultrasound surgery', IEEE transac- tions on biomedical engineering, vol. 51, no. 10, pp. 1693{1706, 2004. [135] G. Pinton, J.-F. Aubry, E. Bossy, M. Muller, M. Pernot and M. Tanter, `Attenuation, scattering, and absorption of ultrasound in the skull bone', Medical physics, vol. 39, no. 1, pp. 299{307, 2012. [136] R. Sharma and F. Gaillard. (2018). Platybasia, [Online]. Available: https://radiopaedia.org/articles/platybasia. [137] J. A. Kanis et al., `Assessment of osteoporosis at the primary healthcare level', Technical Report. WHO Collaborating Centre, University of She�eld, UK, Tech. Rep., 2008. [138] U.S. Preventive Services Task Force, `Screening for osteoporosis: U.S. preventive services task force recommendation statement', Annals of In- ternal Medicine, vol. 154, no. 5, pp. 356{364, 2011. doi: 10.7326/0003- 4819-154-5-201103010-00307. eprint: /data/journals/aim/20227/ 0000605-201103010-00010.pdf. [Online]. Available: +%20http://dx. doi.org/10.7326/0003-4819-154-5-201103010-00307. 174 REFERENCES [139] N. H. Service, `How it is performed, DEXA (DXA) scan', NHS Health A-Z, 2016. [140] N. I. for Health, `What people with diabetes need to know about osteoporosis', Osteoporosis, 2016, https://www.bones.nih.gov/health- info/bone/osteoporosis/conditions-behaviors/diabetes. [141] S. Prins, H. Jorgensen, L. Jorgensen and C. Hassager, `The role of quantitative ultrasound in the assessment of bone: A review', Clin Physiol, 1997. [142] D. Hans, T. Fuerst and F. Duboeuf, `Quantitative ultrasound bone measurement', European radiology, vol. 7, no. 2, S43, 1997. [143] P. Laugier, `Quantitative ultrasound of bone: Looking ahead', Joint Bone Spine, vol. 73, no. 2, pp. 125{128, 2006. [144] Y. Bala, R. Zebaze and E. Seeman, `Role of cortical bone in bone fragility', Current opinion in rheumatology, vol. 27, no. 4, pp. 406{413, 2015. [145] V. C. Protopappas, I. C. Kourtis, L. C. Kourtis, K. N. Malizos, C. V. Massalas and D. I. Fotiadis, `Three-dimensional �nite element modeling of guided ultrasound wave propagation in intact and healing long bones', The Journal of the Acoustical Society of America, vol. 121, no. 6, pp. 3907{3921, 2007. [146] K. Raum, I. Leguerney, F. Chandelier, E. Bossy, M. Talmant, A. Saied, F. Peyrin and P. Laugier, `Bone microstructure and elastic tissue properties are re ected in QUS axial transmission measurements', Ultra- sound in medicine & biology, vol. 31, no. 9, pp. 1225{1235, 2005. [147] N. O. Kuchuk, N. M. Van Schoor, S. M. Pluijm, J. H. Smit, W. De Ronde and P. Lips, `The association of sex hormone levels with quantitative ultrasound, bone mineral density, bone turnover and osteoporotic fractures in older men and women', Clinical endocrinology, vol. 67, no. 2, pp. 295{303, 2007. 175 REFERENCES [148] V. Egorov, A. Tatarinov, N. Sarvazyan, R. Wood, L. Magidenko, S. Amin, S. Khosla, R. J. Ruh, J. M. Ruh and A. Sarvazyan, `Osteoporosis detection in postmenopausal women using axial transmission multifrequency bone ultrasonometer: Clinical �ndings', Ultrasonics, vol. 54, no. 5, pp. 1170{1177, 2014. [149] A. Sarvazyan, A. Tatarinov, V. Egorov, S. Airapetian, V. Kurtenok and C. J. Gatt, `Application of the dual-frequency ultrasonometer for osteoporosis detection', Ultrasonics, vol. 49, no. 3, pp. 331{337, 2009. [150] E. Bossy, M. Talmant and P. Laugier, `E�ect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: A 2D simulation study', The Journal of the Acoustical Society of America, vol. 112, no. 1, pp. 297{307, 2002. [151] ||, `Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models', The Journal of the Acoustical Society of America, vol. 115, no. 5, pp. 2314{2324, 2004. [152] V. Kilappa, K. Xu, P. Moilanen, E. Heikkola, D. Ta and J. Timonen, `Assessment of the fundamental exural guided wave in cortical bone by an ultrasonic axial-transmission array transducer', Ultrasound in medi- cine & biology, vol. 39, no. 7, pp. 1223{1232, 2013. [153] K. D. Evans, B. Weiss and M. Knopp, `High-intensity focused ultrasound (HIFU) for speci�c therapeutic treatments: A literature review', Journal of Diagnostic Medical Sonography, vol. 23, no. 6, pp. 319{327, 2007. [154] R. Illing, J. Kennedy, F. Wu, G. Ter Haar, A. Protheroe, P. Friend, F. Gleeson, D. Cranston, R. Phillips and M. Middleton, `The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a western population', British journal of cancer, vol. 93, no. 8, p. 890, 2005. [155] M. Huisman, G. Ter Haar, A. Napoli, A. Hananel, P. Ghanouni, G. L�ovey, R. J. Nijenhuis, M. A. Van Den Bosch, V. Rieke, S. Majumdar et al., `International consensus on use of focused ultrasound for painful 176 REFERENCES bone metastases: Current status and future directions', International Journal of Hyperthermia, vol. 31, no. 3, pp. 251{259, 2015. [156] D. Bianchini, F. Marcocci, E. Menghi, V. D'Errico, E. Mezzenga and A. Sarnelli, `Treatment plan veri�cation in MRgFUs for bone metastasis pain palliation', Physica Medica: European Journal of Medical Physics, vol. 32, p. 248, 2016. [157] P. Smirnov and K. Hynynen, `Design of a HIFU array for the treatment of deep venous thrombosis: A simulation study.', Physics in medicine and biology, 2017. [158] A. Partanen, P. S. Yarmolenko, A. Viitala, S. Appanaboyina, D. Haemmerich, A. Ranjan, G. Jacobs, D. Woods, J. Enholm, B. J. Wood et al., `Mild hyperthermia with magnetic resonance-guided high-intensity focused ultrasound for applications in drug delivery', International journal of hyperthermia, vol. 28, no. 4, pp. 320{336, 2012. [159] M. Pernot, J.-F. Aubry, M. Tanter, A.-L. Boch, F. Marquet, M. Kujas, D. Seilhean and M. Fink, `In vivo transcranial brain surgery with an ultrasonic time reversal mirror', Journal of neurosurgery, vol. 106, no. 6, pp. 1061{1066, 2007. [160] J. Blackmore, M. Veldsman, C. Butler and R. Cleveland, `Focusing ultrasound through the skull for neuromodulation', The Journal of the Acoustical Society of America, vol. 141, no. 5, pp. 3549{3549, 2017. [161] O. Naor, S. Krupa and S. Shoham, `Ultrasonic neuromodulation', Journal of neural engineering, vol. 13, no. 3, p. 031 003, 2016. [162] A. Pulkkinen, Y. Huang, J. Song and K. Hynynen, `Simulations and measurements of transcranial low-frequency ultrasound therapy: Skullbase heating and e�ective area of treatment', Physics in Medicine & Biology, vol. 56, no. 15, p. 4661, 2011. [163] M. Pernot, J.-F. Aubry, M. Tanter, J.-L. Thomas and M. Fink, `High power transcranial beam steering for ultrasonic brain therapy', Physics in medicine and biology, vol. 48, no. 16, p. 2577, 2003. 177 REFERENCES [164] G. Clement and K. Hynynen, `A non-invasive method for focusing ultrasound through the human skull', Physics in Medicine & Biology, vol. 47, no. 8, p. 1219, 2002. [165] J. White, G. T. Clement and K. Hynynen, `Transcranial ultrasound focus reconstruction with phase and amplitude correction', IEEEE trans- actions on ultrasonics, ferroelectrics, and frequency control, vol. 52, no. 9, pp. 1518{1522, 2005, https://www.nhs.uk/conditions/dexa- scan/what-happens/. [166] H. Estrada, J. Rebling and D. Razansky, `Prediction and near-�eld observation of skull-guided acoustic waves', Physics in Medicine and Biology, vol. 62, p. 4728, 2017. [167] N. Bochud, J.-G. Minonzio, Q. Vallet and P. Laugier, `A genetic algorithmsbased optimization method for estimating thickness and porosity of cortical bone from guided wave measurements', in Ultrasonic Charac- terization of Bone (ESUCB), 2015 6th European Symposium on, IEEE, 2015, pp. 1{4. [168] P. Moilanen, P. Nicholson, V. Kilappa, S. Cheng and J. Timonen, `Measuring guided waves in long bones: Modeling and experiments in free and immersed plates', Ultrasound in medicine & biology, vol. 32, no. 5, pp. 709{719, 2006. [169] J. L. Rose, Ultrasonic waves in solid media, 2000. [170] K. T. Onwuama, S. O. Salami, M. Ali and J. O. Nzalak, `E�ect of di�erent methods of bone preparation on the skeleton of the African giant pouched rat (cricetomys gambianus).', International Journal of Morphology, vol. 30, no. 2, 2012. [171] L. G. Mandarano-Filho, M. T. Bezuti, N. Mazzer and C. H. Barbieri, `In uence of cortical bone thickness on the ultrasound velocity', Acta ortopedica brasileira, vol. 20, no. 3, pp. 184{190, 2012. [172] S. Qiao, X. Shang and E. Pan, `Elastic guided waves in a coated spherical shell', Nondestructive Testing and Evaluation, vol. 31, no. 2, pp. 165{ 190, 2016. 178 REFERENCES [173] A. N. Norris and A. Shuvalov, `Elastodynamics of radially inhomogeneous spherically anisotropic elastic materials in the stroh formalism', in Proc. R. Soc. A, The Royal Society, vol. 468, 2012, pp. 467{484. [174] J. Qu, Y. Berthelot and Z. Li, `Dispersion of guided circumferential waves in a circular annulus', 1996. [175] G. Gaunaurd and M. Werby, `Similarities between various Lamb waves in submerged spherical shells, and rayleigh waves in elastic spheres and at half-spaces', The Journal of the Acoustical Society of Amer- ica, vol. 89, no. 6, pp. 2731{2739, 1991. [176] W. Sachse and Y.-H. Pao, `On the determination of phase and group velocities of dispersive waves in solids', Journal of Applied Physics, vol. 49, no. 8, pp. 4320{4327, 1978. [177] L. Ma�zeika and L. Draudvilien_e, `Analysis of the zero-crossing technique in relation to measurements of phase velocities of the Lamb waves', Ultrasound, vol. 66, no. 2, pp. 7{12, 2010. [178] T. Pialucha, C. Guyott and P. Cawley, `Amplitude spectrum method for the measurement of phase velocity', Ultrasonics, vol. 27, no. 5, pp. 270{ 279, 1989. [179] D. Waltisberg and R. Rai�sutis, `Group velocity estimation of Lamb waves based on the wavelet transform', Ultragarsas (Ultrasound), vol. 63, no. 4, pp. 35{40, 2008. [180] D. N. Alleyne and P. Cawley, `A 2-dimensional Fourier transform method for the quantitative measurement of Lamb modes', in Ultrasonics Sym- posium, 1990. Proceedings., IEEE 1990, IEEE, 1990, pp. 1143{1146. [181] M. Niethammer, L. J. Jacobs, J. Qu and J. Jarzynski, `Time-frequency representations of Lamb waves', The Journal of the Acoustical Society of America, vol. 109, no. 5, pp. 1841{1847, 2001. [182] J.-G. Minonzio, M. Talmant and P. Laugier, `Measurement of guided mode wave vectors by analysis of the transfer matrix obtained with multi-emitters and multi-receivers in contact', in Journal of Physics: Conference Series, IOP Publishing, vol. 269, 2011, p. 012 003. 179 REFERENCES [183] J.-G. Minonzio, M. Talmant and P. Laugier, `Guided wave phase velocity measurement using multi-emitter and multi-receiver arrays in the axial transmission con�guration', The Journal of the Acoustical Society of America, vol. 127, no. 5, pp. 2913{2919, 2010. [184] G. Matrone, A. Savoia, G. Caliano and G. Magenes, `The delay multiply and sum beamforming algorithm in ultrasound b-mode medical imaging.', IEEE Trans. Med. Imaging, vol. 34, no. 4, pp. 940{949, 2015. [185] D.-a. Ta, K. Huang, W.-q. Wang, Y.-y. Wang and L. H. Le, `Identi�cation and analysis of multimode guided waves in tibia cortical bone', Ultrasonics, vol. 44, e279{e284, 2006. [186] J.-G. Minonzio, J. Foiret, P. Moilanen, J. Pirhonen, Z. Zhao, M. Talmant, J. Timonen and P. Laugier, `A free plate model can predict guided modes propagating in tubular bone-mimicking phantoms', The Journal of the Acoustical Society of America, vol. 137, no. 1, EL98{EL104, 2015. [187] P. Ghanouni, K. B. Pauly, W. J. Elias, J. Henderson, J. Sheehan, S. Monteith and M. Wintermark, `Transcranial MRI-guided focused ultrasound: A review of the technologic and neurologic applications', Amer- ican Journal of Roentgenology, vol. 205, no. 1, pp. 150{159, 2015. [188] G. Ter Haar, `Ultrasound focal beam surgery', Ultrasound in medicine & biology, vol. 21, no. 9, pp. 1089{1100, 1995. [189] M. Lee, D. Schlesinger, G. ter Haar, B. Sela, M. Eames, J. Snell, A. Hananel, N. Kassell, J. Sheehan, J. Larner et al., `Thermal dose and radiation dose comparison based on cell survival', Journal of Therapeutic Ultrasound, vol. 3, no. 1, P26, 2015. [190] Z. Izadifar, P. Babyn and D. Chapman, `Mechanical and biological effects of ultrasound: A review of present knowledge', Ultrasound in Medi- cine & Biology, 2017. [191] J. R. McLaughlan, D. M. Cowell and S. Freear, `Gold nanoparticle nucleated cavitation for enhanced high intensity focused ultrasound therapy', Physics in medicine and biology, 2017. 180 REFERENCES [192] C. J. Diederich, `Thermal ablation and high-temperature thermal therapy: Overview of technology and clinical implementation', International journal of hyperthermia, vol. 21, no. 8, pp. 745{753, 2005. [193] L. Zhang and Z.-B.Wang, `High-intensity focused ultrasound tumor ablation: Review of ten years of clinical experience', Frontiers of medicine in China, vol. 4, no. 3, pp. 294{302, 2010. [194] J. E. Kennedy, `High-intensity focused ultrasound in the treatment of solid tumours', Nature reviews cancer, vol. 5, no. 4, pp. 321{327, 2005. [195] A. Blana, F. J. Murat, B. Walter, S. Thuro�, W. F. Wieland, C. Chaussy and A. Gelet, `First analysis of the long-term results with transrectal HIFU in patients with localised prostate cancer', European urology, vol. 53, no. 6, pp. 1194{1203, 2008. [196] N. Sanghvi, F. J. Fry, R. Bihrle, R. Foster, M. Phillips, J. Syrus, A. Zaitsev and C. Hennige, `Noninvasive surgery of prostate tissue by highintensity focused ultrasound', IEEE Transactions on Ultrasonics, Fer- roelectrics, and Frequency Control, vol. 43, no. 6, pp. 1099{1110, 1996. [197] M. Peek, M. Ahmed, A. Napoli, B. ten Haken, S. McWilliams, S. Usiskin, S. Pinder, M. Van Hemelrijck and M. Douek, `Systematic review of high-intensity focused ultrasound ablation in the treatment of breast cancer', British journal of surgery, vol. 102, no. 8, pp. 873{882, 2015. [198] D. Coluccia, J. Fandino, L. Schwyzer, R. O'Gorman, L. Remonda, J. Anon, E. Martin and B.Werner, `First noninvasive thermal ablation of a brain tumor with MR-guided focusedultrasound', Journal of therapeutic ultrasound, vol. 2, no. 1, p. 17, 2014. [199] K. Hynynen, G. T. Clement, N. McDannold, N. Vykhodtseva, R. King, P. J. White, S. Vitek and F. A. Jolesz, `500-element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls', Magnetic resonance in medi- cine, vol. 52, no. 1, pp. 100{107, 2004. 181 REFERENCES [200] H. Gr�ull and S. Langereis, `Hyperthermia-triggered drug delivery from temperature-sensitive liposomes using MRI-guided high intensity focused ultrasound', Journal of Controlled Release, vol. 161, no. 2, pp. 317{ 327, 2012. [201] D. B. Rodrigues, P. R. Stau�er, D. Vrba and M. D. Hurwitz, `Focused ultrasound for treatment of bone tumours', International Journal of Hyperthermia, vol. 31, no. 3, pp. 260{271, 2015. [202] T. R. Wang, R. Dallapiazza and W. J. Elias, `Neurological applications of transcranial high intensity focused ultrasound', International Journal of Hyperthermia, vol. 31, no. 3, pp. 285{291, 2015. [203] J. Xiao, Z. Shi, J. Zhou, J. Ye, J. Zhu, X. Zhou, F. Wang and S. Zhang, `Cesarean scar pregnancy: Comparing the e�cacy and tolerability of treatment with high-intensity focused ultrasound and uterine artery embolization', Ultrasound in medicine & biology, vol. 43, no. 3, pp. 640{ 647, 2017. [204] M. Brown, P. Farquhar-Smith, J. Williams, G. Ter Haar and N. de- Souza, `The use of high-intensity focused ultrasound as a novel treatment for painful conditions a description and narrative review of the literature', BJA: British Journal of Anaesthesia, vol. 115, no. 4, pp. 520{ 530, 2015. [205] M. S. Canney, M. R. Bailey, L. A. Crum, V. A. Khokhlova and O. A. Sapozhnikov, `Acoustic characterization of high intensity focused ultrasound �elds: A combined measurement and modeling approach', J Acoust Soc Am, vol. 124, no. 4, pp. 2406{2420, Oct. 2008, 014810JAS[PII], issn: 0001-4966. doi: 10.1121/1.2967836. [Online]. Available: http: //www.ncbi.nlm.nih.gov/pmc/articles/PMC2677345/. [206] C. A. Cain and S. Umemura, `Concentric-ring and sector-vortex phasedarray applicators for ultrasound hyperthermia', IEEE Transactions on Microwave Theory and Techniques, vol. 34, no. 5, pp. 542{551, May 1986, issn: 0018-9480. doi: 10.1109/TMTT.1986.1133390. 182 REFERENCES [207] P. J. Benkeser, `Unfocused multielement and tapered phased array ultrasound transducers for hyperthermia treatment', PhD thesis, University of Illinois, 1985. [208] J. Sun and K. Hynynen, `The potential of transskull ultrasound therapy and surgery using the maximum available skull surface area', The Journal of the Acoustical Society of America, vol. 105, no. 4, pp. 2519{ 2527, 1999. [209] E. L. Carstensen, S. Z. Child, S. Norton and W. Nyborg, `Ultrasonic heating of the skull', The Journal of the Acoustical Society of America, vol. 87, no. 3, pp. 1310{1317, 1990. [210] F. Fry and J. Barger, `Acoustical properties of the human skull', The Journal of the Acoustical Society of America, vol. 63, no. 5, pp. 1576{ 1590, 1978. [211] G. Clement and K. Hynynen, `Correlation of ultrasound phase with physical skull properties', Ultrasound in medicine & biology, vol. 28, no. 5, pp. 617{624, 2002. [212] Y. Y. Botros, E. S. Ebbini and J. L. Volakis, `Two-step hybrid virtual array ray (var) technique for focusing through the rib cage', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 45, no. 4, pp. 989{1000, 1998. [213] M. Tanter, M. Pernot, J.-F. Aubry, G. Montaldo, F. Marquet and M. Fink, `Compensating for bone interfaces and respiratory motion in highintensity focused ultrasound', International Journal of Hyperthermia, vol. 23, no. 2, pp. 141{151, 2007. [214] A. H. Chan, V. Y. Fujimoto, D. E. Moore, R. W. Martin and S. Vaezy, `An image-guided high intensity focused ultrasound device for uterine �broids treatment', Medical physics, vol. 29, no. 11, pp. 2611{2620, 2002. [215] L. Curiel, F. Chavrier, R. Souchon, A. Birer and J. Y. Chapelon, `1.5-D high intensity focused ultrasound array for non-invasive prostate cancer surgery', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 49, no. 2, pp. 231{242, 2002. 183 REFERENCES [216] S. C. Tang and G. T. Clement, `Acoustic standing wave suppression using randomized phase-shift-keying excitations', The Journal of the Acoustical Society of America, vol. 126, no. 4, pp. 1667{1670, 2009. [217] J.-F. Aubry, `Focusing ultrasound through bones: Past, current, and future transcostal and transskull strategies', The Journal of the Acous- tical Society of America, vol. 141, no. 5, pp. 3549{3549, 2017. [218] S. Concepts, H- transducer series �64 mm, http://bit.ly/2EOrwK6, accessed 23/02/2018. [219] P. Acoustics, HIFU transducers, https://www.acoustics.co.uk/ product/{HIFU}-transducers/, accessed 23/02/2018. [220] P. Davari, N. Ghasemi, F. Zare, P. O'shea and A. Ghosh, `Improving the e�ciency of high power piezoelectric transducers for industrial applications', IET Science, Measurement & Technology, vol. 6, no. 4, pp. 213{221, 2012. [221] S. Tamano, H. Jimbo, T. Azuma, S. Yoshizawa, K. Fujiwara, K. Itani and S.-I. Umemura, `Improvement of high-voltage staircase drive circuit waveform for high-intensity therapeutic ultrasound', Japanese Journal of Applied Physics, vol. 55, no. 7S1, 07KF17, 2016. [222] P. Kaczkowski, `Arbitrary waveform generation with the verasonics research ultrasound platform', Verasonics Inc., Tech. Rep., 2016. [223] G. K. Lewis Jr and W. L. Olbricht, `Design and characterization of a high-power ultrasound driver with ultralow-output impedance', Review of scienti�c instruments, vol. 80, no. 11, p. 114 704, 2009. [224] W. Wong, C. Christo�ersen, S. Pichardo and L. Curiel, `An integrated ultrasound transducer driver for HIFU applications', in Electrical and Computer Engineering (CCECE), 2013 26th Annual IEEE Canadian Conference on, IEEE, 2013, pp. 1{5. [225] K. Moro, S. Yoshizawa and S.-i. Umemura, `Staircase-voltage metal{ oxide{semiconductor �eld-e�ect transistor driver circuit for therapeutic ultrasound', Japanese Journal of Applied Physics, vol. 49, no. 7S, 07HF02, 2010. 184 REFERENCES [226] A. Berkovich, A. Bursian, K. Zaychenko and N. Petrishchev, `A highfrequency generator used in high-intensity focused ultrasound transducers for tissue ablation and vessel obliteration', Biomedical Engin- eering, vol. 51, no. 3, pp. 215{217, 2017. [227] D. M. Cowell, P. R. Smith and S. Freear, `Phase-inversion-based selective harmonic elimination (PI-SHE) in multi-level switched-mode toneand frequency-modulated excitation', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 60, no. 6, pp. 1084{1097, 2013. [228] S. Harput, M. Arif, J. McLaughlan, D. J. Cowell and S. Freear, `The e�ect of amplitude modulation on subharmonic imaging with chirp excitation', IEEE transactions on ultrasonics, ferroelectrics, and frequency control, vol. 60, no. 12, pp. 2532{2544, 2013. [229] B. E. Treeby, J. Jaros, A. P. Rendell and B. Cox, `Modeling nonlinear ultrasound propagation in heterogeneous media with power law absorption using a k-space pseudospectral method', The Journal of the Acoustical Society of America, vol. 131, no. 6, pp. 4324{4336, 2012. [230] D. Nassiri, D. Nicholas and C. Hill, `Attenuation of ultrasound in skeletal muscle', Ultrasonics, vol. 17, no. 5, pp. 230{232, 1979. [231] W. L. Nyborg, `Heat generation by ultrasound in a relaxing medium', The Journal of the Acoustical Society of America, vol. 70, no. 2, pp. 310{ 312, 1981. doi: 10.1121/1.386778. eprint: https://doi.org/10. 1121/1.386778. [232] H. H. Pennes, `Analysis of tissue and arterial blood temperatures in the resting human forearm', Journal of applied physiology, vol. 1, no. 2, pp. 93{122, 1948. [233] S. A. Sapareto and W. C. Dewey, `Thermal dose determination in cancer therapy', International Journal of Radiation Oncology* Biology* Physics, vol. 10, no. 6, pp. 787{800, 1984. [234] P. S. Yarmolenko, E. J. Moon, C. Landon, A. Manzoor, D. W. Hochman, B. L. Viglianti and M. W. Dewhirst, `Thresholds for thermal damage to normal tissues: An update', International Journal of Hyperthermia, vol. 27, no. 4, pp. 320{343, 2011. 185 REFERENCES [235] J. McLaughlan, I. Rivens, T. Leighton and G. Ter Haar, `A study of bubble activity generated in ex vivo tissue by high intensity focused ultrasound', Ultrasound in medicine & biology, vol. 36, no. 8, pp. 1327{ 1344, 2010. [236] P. Lai, J. R. McLaughlan, A. B. Draudt, T. W. Murray, R. O. Cleveland and R. A. Roy, `Real-time monitoring of high-intensity focused ultrasound lesion formation using acousto-optic sensing', Ultrasound in medicine & biology, vol. 37, no. 2, pp. 239{252, 2011. [237] Y. Zhou, L. Zhai, R. Simmons and P. Zhong, `Measurement of high intensity focused ultrasound �elds by a �ber optic probe hydrophone', The Journal of the Acoustical Society of America, vol. 120, no. 2, pp. 676{ 685, 2006. [238] G. ter Haar, A. Shaw, S. Pye, B. Ward, F. Bottomley, R. Nolan and A.-M. Coady, `Guidance on reporting ultrasound exposure conditions for bio-e�ects studies', Ultrasound in Medicine and Biology, vol. 37, no. 2, pp. 177{183, 2011. [239] W. W. Elliott AC, Statistical analysis quick reference guidebook with SPSS examples. Sage Publications, 2007. [240] T. Leighton, The acoustic bubble. Academic press, 2012. [241] K. Hynynen, Impedance matching for ultrasound phased array elements, US Patent 9,387,515, Jul. 2016. [242] C. Hill, `Calibration of ultrasonic beams for bio-medical applications', Physics in Medicine & Biology, vol. 15, no. 2, p. 241, 1970. [243] J. R. McLaughlan, `An investigation into the use of cavitation for the optimisation of high intensity focused ultrasound (HIFU) treatments', PhD thesis, Institute of Cancer Research (University Of London), 2008."],"dcterms:accessrights":["public"],"dc:title":["The Generation and Control of Ultrasonic Waves in Nonlinear Media"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:31:21Z"}