{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:23344"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:23344","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Passive Robotics for Accelerated Collaborative Therapy","abstract":"Each year 110,000 stroke cases are reported in the UK. 300,000 people are living with post-stroke complications, which for many include upper limb impairment. After-stroke therapy is most effective during the first 12 weeks, but improvement can continue for months or even years. To date, a number of devices prioritising early stroke rehabilitation have been developed, however most of these devices are active devices and cannot be used by patients without constant supervision due to safety concerns. In this work a low-cost, portable inherently safe rehabilitation robot is introduced. The robot is designed for use on existing table space in a home environment. Estimates of the robot's 2D position and orientation are computed by fusing data from two tracking systems, each utilizing a different sensor type: laser optical sensors and a webcam. Two laser optical sensors are mounted on the underside of the robot and track the relative motion of the robot with respect to the surface on which it is placed. The webcam is positioned directly above the workspace, mounted on a fixed stand, and tracks the robot's position with respect to a fixed coordinate system. The optical sensors sample the position data at a higher frequency than the webcam. A position and orientation fusion scheme is proposed to fuse the data from the two tracking systems. Active movements of a patient using the robot are assisted in real time by a custom-designed inherently safe guidance mechanism based on a COBOT unicycle architecture and capable of creating 2D virtual constraints. The guidance mechanism is mounted on the underside of the robot and in its centre, and is accompanied by four custom designed caster wheels with low rolling resistance. The guidance mechanism is actuated with a stepper motor, but no active force acting on the upper limb of the patient is generated. A prototype of the robot was manufactured and evaluated in a series of experiments including user testing with 38 healthy bodied adults. It was found that the robot is clearly capable of applying a passive force of suffcient magnitude and in the right direction to increase the accuracy with which able bodied adults can perform reaching arm movements. The resistance to movement of the robot, both friction and inertia are suffciently low that they do not appear to reduce the subjects' ability to move at normal reaching movement speeds.","abstract_html":"Each year 110,000 stroke cases are reported in the UK. 300,000 people are living with post-stroke complications, which for many include upper limb impairment. After-stroke therapy is most effective during the first 12 weeks, but improvement can continue for months or even years. To date, a number of devices prioritising early stroke rehabilitation have been developed, however most of these devices are active devices and cannot be used by patients without constant supervision due to safety concerns. In this work a low-cost, portable inherently safe rehabilitation robot is introduced. The robot is designed for use on existing table space in a home environment. Estimates of the robot&#x27;s 2D position and orientation are computed by fusing data from two tracking systems, each utilizing a different sensor type: laser optical sensors and a webcam. Two laser optical sensors are mounted on the underside of the robot and track the relative motion of the robot with respect to the surface on which it is placed. The webcam is positioned directly above the workspace, mounted on a fixed stand, and tracks the robot&#x27;s position with respect to a fixed coordinate system. The optical sensors sample the position data at a higher frequency than the webcam. A position and orientation fusion scheme is proposed to fuse the data from the two tracking systems. Active movements of a patient using the robot are assisted in real time by a custom-designed inherently safe guidance mechanism based on a COBOT unicycle architecture and capable of creating 2D virtual constraints. The guidance mechanism is mounted on the underside of the robot and in its centre, and is accompanied by four custom designed caster wheels with low rolling resistance. The guidance mechanism is actuated with a stepper motor, but no active force acting on the upper limb of the patient is generated. A prototype of the robot was manufactured and evaluated in a series of experiments including user testing with 38 healthy bodied adults. It was found that the robot is clearly capable of applying a passive force of suffcient magnitude and in the right direction to increase the accuracy with which able bodied adults can perform reaching arm movements. The resistance to movement of the robot, both friction and inertia are suffciently low that they do not appear to reduce the subjects&#x27; ability to move at normal reaching movement speeds.","abstract_has_math":false,"creators":["Wojewoda, Kazimierz Krzysztof"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Levesley, Martin","Culmer, Peter","Jackson, Andrew"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-02","date_published":"2018-02","updated_at":"2026-11-18T22:31:49Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/23344/1/Wojewoda_KK_Mechanical_PhD_2018.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A23344","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Levesley, Martin","Culmer, Peter","Jackson, Andrew"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC"]},{"key":"dc:creator","label":"Author","values":["Wojewoda, Kazimierz Krzysztof"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-02"]},{"key":"dc:date.issued","label":"Date","values":["2018-02"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Mechanical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/23344/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Amirabdollahian, F., Harwin, W. & Loureiro, R. (2007). Analysis of the fuglmeyer outcome measures assessing the e�ectiveness of robot-mediated stroke therapy. In Rehabilitation Robotics, 2007. ICORR 2007. IEEE 10th International Conference on, 729{735, IEEE. 42 Barnes, M.P. & Johnson, G.R. (2008). Upper motor neurone syndrome and spasticity: clinical management and neurophysiology. Cambridge University Press. 9, 10 Bill, G., Insurance, L., Insurance, T.I., Prescriptions, R., Prevention, C., Headstones, M., Certificates, M.P.M., Locator, N.G., Flags, B., Al- lowance, B. et al. (2011). Bilateral upper-limb rehabilitation after stroke using a movement-based game controller. 26, 27 Bradner, S. (1997). Key words for use in rfcs to indicate requirement levels. 69 Brookes, J., Kuznecovs, M., Kanakis, M., Grigals, A., Narvidas, M., Gal- lagher, J. & Levesley, M. (2017). Robots testing robots: Alan-arm, a humanoid arm for the testing of robotic rehabilitation systems. In Rehabilitation Robotics (ICORR), 2017 International Conference on, 676{681, IEEE. 114 Byl, N., Roderick, J., Mohamed, O., Hanny, M., Kotler, J., Smith, A., Tang, M. & Abrams, G. (2003). E�ectiveness of sensory and motor rehabilitation of the upper limb following the principles of neuroplasticity: patients stable poststroke. Neu- rorehabilitation and neural repair , 17, 176{191. 18 Cabral, N.L., Moro, C., Silva, G.R., Scola, R.H. & Werneck, L.C. (2003). Study comparing the stroke unit outcome and conventional ward treatment: a randomized study in joinville, brazil. Arquivos de neuro-psiquiatria, 61, 188{193. 10 205 REFERENCES Casadio, M., Sanguineti, V., Morasso, P.G. & Arrichiello, V. (2006). Braccio di ferro: a new haptic workstation for neuromotor rehabilitation. Technology and Health Care, 14, 123{142. xvi, 37, 38, 60 CCOHS (2008). What can workers do to reduce the discomfort of working in a standing position? http://www.ccohs.ca/oshanswers/ergonomics/standing/standing_ basic.html, accessed: 2014-09-25. xvii, 60, 61 Chua, J.Y. (2006). Design of a wearable cobot. xvi, xvii, 57, 58, 59 Cincura, C., Pontes-Neto, O.M., Neville, I.S., Mendes, H.F., Menezes, D.F., Mariano, D.C., Pereira, I.F., Teixeira, L.A., Jesus, P.A., de Queiroz, D.C. et al. (2009). Validation of the national institutes of health stroke scale, modi�ed rankin scale and barthel index in brazil: The role of cultural adaptation and structured interviewing. Cerebrovasc Dis, 27, 119{122. 10 Coote, S., Murphy, B., Harwin, W. & Stokes, E. (2008). The e�ect of the gentle/s robot-mediated therapy system on arm function after stroke. Clinical rehabilitation, 22, 395{405. 42 Culmer, P.R. (2007). Development of a Cooperative Robot System to Aid Stroke Reha- bilitation. Ph.D. thesis, University of Leeds. 8, 9, 10, 17, 18 Culmer, P.R., Levesley, M.C., Mon-Williams, M. & Williams, J.H. (2009). A new tool for assessing human movement: the kinematic assessment tool. Journal of neuroscience methods, 184, 184{192. 119 Daly, J.J., Hogan, N., Perepezko, E.M., Krebs, H.I., Rogers, J.M., Goyal, K.S., Dohring, M.E., Fredrickson, E., Nethery, J. & Ruff, R.L. (2005). Response to upper-limb robotics and functional neuromuscular stimulation following stroke. Journal of rehabilitation research & development, 42. 54 Dietz, V., Nef, T. & Zev Rymer, W. (2012). Neurorehabilitation Technology. Springer. 33, 49 Directive, C. (1993). 93/42/eec of 14 june 1993 concerning medical devices. 61, 62, 70, 151 206 REFERENCES Dobkin, B.H. (2004). Strategies for stroke rehabilitation. The Lancet Neurology, 3, 528{ 536. 2 Elmenreich, W. (2007). A review on system architectures for sensor fusion applications. Software Technologies for Embedded and Ubiquitous Systems, 547{559. 110 EPP (2006). Workstation design. http://www.ccohs.ca/oshanswers/ergonomics/ standing/standing_basic.html, accessed: 2014-09-25. xvii, 60, 61 Fess, E., Gettle, K., Philips, C. & Robin, J. (2005). Hand and upper extremity splinting. 82 Feys, H., De Weerdt, W., Verbeke, G., Steck, G.C., Capiau, C., Kiekens, C., Dejaeger, E., Van Hoydonck, G., Vermeersch, G. & Cras, P. (2004). Early and repetitive stimulation of the arm can substantially improve the long-term outcome after stroke: a 5-year follow-up study of a randomized trial. Stroke, 35, 924{929. 17 Fischer, U., Baumgartner, A., Arnold, M., Nedeltchev, K., Gralla, J., Marco De Marchis, G., Kappeler, L., Mono, M.L., Brekenfeld, C., Schroth, G. et al. (2010). What is a minor stroke? Stroke, 41, 661{666. 8 Gallagher, J., Preston, N., Holt, R., Mon-Williams, M., Levesley, M. & Weightman, A. (2015). Assessment of upper limb movement with an autonomous robotic device in a school environment for children with cerebral palsy. In Rehabilitation Robotics (ICORR), 2015 IEEE International Conference on, 770{774, IEEE. 114 Gillen, G. (2010). Stroke rehabilitation: a function-based approach. Elsevier Health Sciences. 7 Gillespie, R.B., Colgate, J.E. & Peshkin, M.A. (2001). A general framework for cobot control. Robotics and Automation, IEEE Transactions on, 17, 391{401. 56 Gladstone, D.J., Danells, C.J. & Black, S.E. (2002). The fugl-meyer assessment of motor recovery after stroke: a critical review of its measurement properties. Neurore- habilitation and neural repair , 16, 232{240. xxv, 8, 12, 13, 14 207 REFERENCES He, J., Koeneman, E., Schultz, R., Huang, H., Wanberg, J., Herring, D., Sugar, T., Herman, R. & Koeneman, J. (2005). Design of a robotic upper extremity repetitive therapy device. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 95{98, IEEE. xvi, 52 Herder, J. (2005). Development of a statically balanced arm support: Armon. In Re- habilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 281{286, IEEE. 36 Herder, J.L., Vrijlandt, N., Antonides, T., Cloosterman, M., Mastenbroek, P.L. et al. (2006). Principle and design of a mobile arm support for people with muscular weakness. Journal of rehabilitation research and development, 43, 591. 36 Hesse, S., Schulte-Tigges, G., Konrad, M., Bardeleben, A. & Werner, C. (2003). Robot-assisted arm trainer for the passive and active practice of bilateral forearm and wrist movements in hemiparetic subjects. Archives of physical medicine and rehabilitation, 84, 915{920. xv, 30, 31 Hesse, S., Schmidt, H., Werner, C., Rybski, C., Puzich, U. & Bardeleben, A. (2007). A new mechanical arm trainer to intensify the upper limb rehabilitation of severely a�ected patients after stroke: design, concept and �rst case series. Europa medicophysica, 43, 463{468. 31 Housman, S.J., Le, V., Rahman, T., Sanchez, R.J. & Reinkensmeyer, D.J. (2007). Arm-training with t-wrex after chronic stroke: preliminary results of a randomized controlled trial. In Rehabilitation Robotics, 2007. ICORR 2007. IEEE 10th International Conference on, 562{568, IEEE. 49 Housman, S.J., Scott, K.M. & Reinkensmeyer, D.J. (2009). A randomized controlled trial of gravity-supported, computer-enhanced arm exercise for individuals with severe hemiparesis. Neurorehabilitation and neural repair . 16, 20, 49 Howard, V.J., McClure, L.A., Meschia, J.F., Pulley, L., Orr, S.C. & Friday, G.H. (2006). High prevalence of stroke symptoms among persons without a diagnosis of stroke or transient ischemic attack in a general population: the reasons for geographic and racial di�erences in stroke (regards) study. Archives of internal medicine, 166, 1952{1958. 8 208 REFERENCES Jackson, A., Levesley, M., Makower, S., Cozens, J. & Bhakta, B. (2013). Development of the ipam mkii system and description of a randomized control trial with acute stroke patients. In IEEE... International Conference on Rehabilitation Robotics:[proceedings], vol. 2013, 6650407{6650407. xvi, 44, 45 Jahanshahloo, G.R., Lotfi, F.H. & Izadikhah, M. (2006). An algorithmic method to extend topsis for decision-making problems with interval data. Applied mathematics and computation, 175, 1375{1384. xxv, 75, 76 Johnson, M., Van der Loos, H., Burgar, C. & Leifer, L. (1999). Driver's seat: simulation environment for arm therapy. In Proceedings of the 6th International Con- ference on Rehabilitation Robotics (ICORR'99), Stanford, CA, US. xvi, 39, 40 Johnson, M., Wisneski, K., Anderson, J., Nathan, D. & Smith, R. (2006). Development of adler: The activities of daily living exercise robot. In Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on, 881{886, IEEE. 42 Kim, Y.S., Lee, J., Lee, S. & Kim, M. (2005). A force re ected exoskeleton-type masterarm for human-robot interaction. Systems, Man and Cybernetics, Part A: Systems and Humans, IEEE Transactions on, 35, 198{212. xvi, 48, 49 Knecht, S., Hesse, S. & Oster, P. (2011). Rehabilitation after stroke. Deutsches � Arzteblatt International, 108, 600. 15 Kowalczewski, J., Ravid, E. & Prochazka, A. (2011). Fully-automated test of upper-extremity function. In Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE, 7332{7335, IEEE. 19, 33 Krakauer, J.W. (2006). Motor learning: its relevance to stroke recovery and neurorehabilitation. Current opinion in neurology, 19, 84{90. 63 Krebs, H.I., Volpe, B.T., Williams, D., Celestino, J., Charles, S.K., Lynch, D. & Hogan, N. (2007). Robot-aided neurorehabilitation: a robot for wrist rehabilitation. Neural Systems and Rehabilitation Engineering, IEEE Transactions on, 15, 327{335. 44 209 REFERENCES Kwakkel, G. & Meskers, C.G. (2014). E�ects of robotic therapy of the arm after stroke. The Lancet Neurology, 13, 132{133. 19, 51, 63, 126 Kwakkel, G., Wagenaar, R.C., Twisk, J.W., Lankhorst, G.J. & Koetsier, J.C. (1999). Intensity of leg and arm training after primary middle-cerebral-artery stroke: a randomised trial. The Lancet, 354, 191{196. xv, 1, 16, 17 Kwakkel, G., Kollen, B.J. & Krebs, H.I. (2008). E�ects of robot-assisted therapy on upper limb recovery after stroke: a systematic review. Neurorehabilitation and neural repair , 22, 111{121. 18, 53, 54, 55 Langhorne, P., Bernhardt, J. & Kwakkel, G. (2011). Stroke rehabilitation. The Lancet, 377, 1693{1702. 16 Lawrence, E.S., Coshall, C., Dundas, R., Stewart, J., Rudd, A.G., Howard, R. & Wolfe, C.D. (2001). Estimates of the prevalence of acute stroke impairments and disability in a multiethnic population. Stroke, 32, 1279{1284. 8 Levin, M.F., Sveistrup, H. & Subramanian, S. (2010). Feedback and virtual environments for motor learning and rehabilitation. Schedae, 1, 19{36. 16, 17 Lo, A.C., Guarino, P.D., Richards, L.G., Haselkorn, J.K., Wittenberg, G.F., Federman, D.G., Ringer, R.J., Wagner, T.H., Krebs, H.I., Volpe, B.T. et al. (2010). Robot-assisted therapy for long-term upper-limb impairment after stroke. New England Journal of Medicine, 362, 1772{1783. 1, 8, 54, 55 Loureiro, R.C., Harwin, W.S., Nagai, K. & Johnson, M. (2011). Advances in upper limb stroke rehabilitation: a technology push. Medical & biological engineering & computing, 49, 1103{1118. 2, 18, 19, 20, 42, 46, 53, 54, 55, 62, 63 Lum, P., Burgar, C.G., Van der Loos, M., Shor, P., Majmundar, M. & Yap, R. (2005). The mime robotic system for upper-limb neuro-rehabilitation: results from a clinical trial in subacute stroke. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 511{514, IEEE. xvi, 44, 45 Luo, D., Schauer, T., Roth, M. & Raisch, J. (2012). Position and orientation control of an omni-directional mobile rehabilitation robot. In Control Applications (CCA), 2012 IEEE International Conference on, 50{56, IEEE. 26, 80, 93, 111, 125 210 REFERENCES Masory, O. & Sanroma, O. (2013). Upper-limbs rehabilitation devices part ii-passive devices. In RESNA ANNUAL CONFERENCE, RESNA. 34 Montagner, A., Frisoli, A., Borelli, L., Procopio, C., Bergamasco, M., Car- boncini, M.C. & Rossi, B. (2007). A pilot clinical study on robotic assisted rehabilitation in vr with an arm exoskeleton device. In Virtual Rehabilitation, 2007 , 57{64, IEEE. xvi, 51 Morse, A. & General, A. (2010). Progress in improving stroke care. 1 Nef, T. & Riener, R. (2005). Armin-design of a novel arm rehabilitation robot. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 57{60, IEEE. 16, 19, 47, 50 Nef, T., Mihelj, M., Colombo, G. & Riener, R. (2006). Armin-robot for rehabilitation of the upper extremities. In Robotics and Automation, 2006. ICRA 2006. Proceedings 2006 IEEE International Conference on, 3152{3157, IEEE. 51 Nef, T., Mihelj, M. & Riener, R. (2007). Armin: a robot for patient-cooperative arm therapy. Medical & biological engineering & computing, 45, 887{900. xvi, 51 Nicosevici, T., Garcia, R., Carreras, M. & Villanueva, M. (2004). A review of sensor fusion techniques for underwater vehicle navigation. In OCEANS'04. MTTS/IEEE TECHNO-OCEAN'04, vol. 3, 1600{1605, IEEE. 110 NINDS (2018). Nih stroke scale. https://www.ninds.nih.gov/sites/default/files/ NIH_Stroke_Scale_Booklet.pdf, accessed: 2018-12-30. 10 Norouzi-Gheidari, N., Archambault, P.S. & Fung, J. (2012). E�ects of robotassisted therapy on stroke rehabilitation in upper limbs: systematic review and metaanalysis of the literature. J Rehabil Res Dev, 49, 479{496. 1, 2 Organization, W.H. et al. (2011). World report on disability 2011. xv, 14, 15 Peattie, A., Korevaar, A., Wilson, J., Sandilands, B., Chen, X. & King, M. (2009). Automated variable resistance system for upper limb rehabilitation. Robotics and Automation. 24, 80, 92, 125 211 REFERENCES Perry, J.C., Zabaleta, H., Belloso, A., Rodr��guez-de Pablo, C., Cavallaro, F.I. & Keller, T. (2012). Armassist: development of a functional prototype for at-home telerehabilitation of post-stroke arm impairment. In Biomedical Robotics and Biomechatronics (BioRob), 2012 4th IEEE RAS & EMBS International Conference on, 1561{1566, IEEE. 22, 23, 70, 80, 92, 93, 122, 125 Peshkin, M. & Colgate, J.E. (1999). Cobots. Industrial Robot: An International Jour- nal, 26, 335{341. 57 Peshkin, M.A., Colgate, J.E., Wannasuphoprasit, W., Moore, C.A., Gille- spie, R.B. & Akella, P. (2001). Cobot architecture. Robotics and Automation, IEEE Transactions on, 17, 377{390. xvi, xvii, 56, 57, 58, 59 powerandsamplesize.com (2018). Calculate sample size needed to compare 2 means: 2- sample, 1-sided. http://powerandsamplesize.com/Calculators/Compare-2-Means/ 2-Sample-1-Sided, accessed: 2018-12-30. 189 Reinkensmeyer, D.J., Dewald, J.P. & Rymer, W.Z. (1999). Guidance-based quanti �cation of arm impairment following brain injury: a pilot study. Rehabilitation Engi- neering, IEEE Transactions on, 7, 1{11. xv, 35, 36 Reinkensmeyer, D.J., Kahn, L.E., Averbuch, M., McKenna-Cole, A., Schmit, B.D. & Rymer, W.Z. (2000). Understanding and treating arm movement impairment after chronic brain injury: progress with the arm guide. Journal of rehabilitation research and development, 37, 653{662. 36 Riener, R., Nef, T. & Colombo, G. (2005). Robot-aided neurorehabilitation of the upper extremities. Medical and Biological Engineering and Computing, 43, 2{10. 20, 43 Rohrer, B., Fasoli, S., Krebs, H.I., Hughes, R., Volpe, B., Frontera, W.R., Stein, J. & Hogan, N. (2002). Movement smoothness changes during stroke recovery. The Journal of Neuroscience, 22, 8297{8304. 94, 99 Rosamond, W.D., Gorton, R.A., Hinn, A.R., Hohenhaus, S.M. & Morris, D.L. (1998). Rapid response to stroke symptoms: the delay in accessing stroke healthcare (dash) study. Academic Emergency Medicine, 5, 45{51. 7 212 REFERENCES Sacco, R.L., Kasner, S.E., Broderick, J.P., Caplan, L.R., Culebras, A., Elkind, M.S., George, M.G., Hamdan, A.D., Higashida, R.T., Hoh, B.L. et al. (2013). An updated de�nition of stroke for the 21st century a statement for healthcare professionals from the american heart association/american stroke association. Stroke, 44, 2064{2089. 7 Sanchez Jr, R., Wolbrecht, E., Smith, R., Liu, J., Rao, S., Cramer, S., Rah- man, T., Bobrow, J. & Reinkensmeyer, D. (2005). A pneumatic robot for retraining arm movement after stroke: Rationale and mechanical design. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 500{504, IEEE. xvi, 52 Shah, S., Vanclay, F. & Cooper, B. (1989). Improving the sensitivity of the barthel index for stroke rehabilitation. Journal of clinical epidemiology, 42, 703{709. xxv, 10, 11, 12 Stienen, A.H., Hekman, E.E., Van der Helm, F.C., Prange, G.B., Jannink, M.J., Aalsma, A.M. & Van der Kooij, H. (2007a). Dampace: dynamic forcecoordination trainer for the upper extremities. In Rehabilitation Robotics, 2007. ICORR 2007. IEEE 10th International Conference on, 820{826, IEEE. 47 Stienen, A.H., Hekman, E.E., Van der Helm, F.C., Prange, G.B., Jannink, M.J., Aalsma, A.M. & Van der Kooij, H. (2007b). Freebal: dedicated gravity compensation for the upper extremities. In Rehabilitation Robotics, 2007. ICORR 2007. IEEE 10th International Conference on, 804{808, IEEE. 39, 40 Stienen, A.H., Hekman, E.E., Prange, G.B., Jannink, M.J., Aalsma, A.M., van der Helm, F.C. & van der Kooij, H. (2009a). Dampace: Design of an exoskeleton for force-coordination training in upper-extremity rehabilitation. Journal of Medical Devices, 3, 031003. 47 Stienen, A.H., Hekman, E.E., Prange, G.B., Jannink, M.J., van der Helm, F.C. & van der Kooij, H. (2009b). Freebal: design of a dedicated weight-support system for upper-extremity rehabilitation. Journal of Medical Devices, 3, 041009. 40 Stienen, A.H.A. (2009). Development of novel devices for upper-extremity rehabilitation. University of Twente. 43 213 REFERENCES Sukal, T.M., Ellis, M.D. & Dewald, J.P. (2005). Dynamic characterization of upper limb discoordination following hemiparetic stroke. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 519{521, IEEE. 42 Tomi�c, T.J.D., Savi�c, A.M., Vidakovi�c, A.S., Rodi�c, S.Z., Isakovi�c, M.S., Rodr��guez-de Pablo, C., Keller, T. & Konstantinovi�c, L.M. (2017). Armassist robotic system versus matched conventional therapy for poststroke upper limb rehabilitation: a randomized clinical trial. BioMed research international, 2017. 56 Toth, A., Fazekas, G., Arz, G., Jurak, M. & Horvath, M. (2005). Passive robotic movement therapy of the spastic hemiparetic arm with reharob: report of the �rst clinical test and the follow-up system improvement. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 127{130, IEEE. xvi, 44, 45 van Delden, A., Peper, C.L.E., Kwakkel, G. & Beek, P.J. (2012). A systematic review of bilateral upper limb training devices for poststroke rehabilitation. Stroke research and treatment, 2012. 28, 29, 31, 32 van Delden, A.L.E., Peper, C.L.E., Harlaar, J., Daffertshofer, A., Zijp, N.I., Nienhuys, K., Koppe, P., Kwakkel, G. & Beek, P.J. (2009). Comparing unilateral and bilateral upper limb training: the ultra-stroke program design. BMC neurology, 9, 57. 29 Veerbeek, J.M., Langbroek-Amersfoort, A.C., Van Wegen, E.E., Meskers, C.G. & Kwakkel, G. (2017). E�ects of robot-assisted therapy for the upper limb after stroke: a systematic review and meta-analysis. Neurorehabilitation and neural repair , 31, 107{121. 53, 55, 62, 63 Wannasuphoprasit, W. (1999). Cobots: Collaborative robots. ProQuest Dissertations and Theses, 1{13. 57 Wannasuphoprasit, W., Gillespie, R.B., Colgate, J.E. & Peshkin, M.A. (1997). Cobot control. In Robotics and Automation, 1997. Proceedings., 1997 IEEE Interna- tional Conference on, vol. 4, 3571{3576, IEEE. 56 Welch, G. & Bishop, G. (1995). An introduction to the kalman �lter. university of north carolina, department of computer science. Tech. rep., TR 95-041. 97 214 REFERENCES Wojewoda, K., Culmer, P., Gallagher, J., Jackson, A. & Levesley, M. (2017). Hybrid position and orientation tracking for a passive rehabilitation table-top robot. In Rehabilitation Robotics (ICORR), 2017 International Conference on, 702{707, IEEE. 196 Wojewoda, K.K., Culmer, P.R., Jackson, A.E. & Levesley, M.C. (2016). Position tracking of a passive rehabilitation robot. In Cyber Technology in Automation, Control, and Intelligent Systems (CYBER), 2016 IEEE International Conference on, 1{6, IEEE. 116, 119, 121, 196 Wong, C.K., Jordan, K. & King, M. (2011). Robotic arm skate for stroke rehabilitation. In Rehabilitation Robotics (ICORR), 2011 IEEE International Conference on, 1{6, IEEE. 25, 80, 93, 125 Zabaleta, H., Valencia, D., Perry, J., Veneman, J. & Keller, T. (2011). Absolute position calculation for a desktop mobile rehabilitation robot based on three optical mouse sensors. In Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE, 2069{2072, IEEE. 92"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/23344/1/Wojewoda_KK_Mechanical_PhD_2018.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Each year 110,000 stroke cases are reported in the UK. 300,000 people are living with post-stroke complications, which for many include upper limb impairment. After-stroke therapy is most effective during the first 12 weeks, but improvement can continue for months or even years. To date, a number of devices prioritising early stroke rehabilitation have been developed, however most of these devices are active devices and cannot be used by patients without constant supervision due to safety concerns. In this work a low-cost, portable inherently safe rehabilitation robot is introduced. The robot is designed for use on existing table space in a home environment. Estimates of the robot's 2D position and orientation are computed by fusing data from two tracking systems, each utilizing a different sensor type: laser optical sensors and a webcam. Two laser optical sensors are mounted on the underside of the robot and track the relative motion of the robot with respect to the surface on which it is placed. The webcam is positioned directly above the workspace, mounted on a fixed stand, and tracks the robot's position with respect to a fixed coordinate system. The optical sensors sample the position data at a higher frequency than the webcam. A position and orientation fusion scheme is proposed to fuse the data from the two tracking systems. Active movements of a patient using the robot are assisted in real time by a custom-designed inherently safe guidance mechanism based on a COBOT unicycle architecture and capable of creating 2D virtual constraints. The guidance mechanism is mounted on the underside of the robot and in its centre, and is accompanied by four custom designed caster wheels with low rolling resistance. The guidance mechanism is actuated with a stepper motor, but no active force acting on the upper limb of the patient is generated. A prototype of the robot was manufactured and evaluated in a series of experiments including user testing with 38 healthy bodied adults. It was found that the robot is clearly capable of applying a passive force of suffcient magnitude and in the right direction to increase the accuracy with which able bodied adults can perform reaching arm movements. The resistance to movement of the robot, both friction and inertia are suffciently low that they do not appear to reduce the subjects' ability to move at normal reaching movement speeds."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Passive Robotics for Accelerated Collaborative Therapy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Levesley, Martin","Culmer, Peter","Jackson, Andrew"],"dc:contributor.sponsor":["EPSRC"],"dc:creator":["Wojewoda, Kazimierz Krzysztof"],"dc:date":["2018-02"],"dc:date.issued":["2018-02"],"dc:description.abstract":["Each year 110,000 stroke cases are reported in the UK. 300,000 people are living with post-stroke complications, which for many include upper limb impairment. After-stroke therapy is most effective during the first 12 weeks, but improvement can continue for months or even years. To date, a number of devices prioritising early stroke rehabilitation have been developed, however most of these devices are active devices and cannot be used by patients without constant supervision due to safety concerns. In this work a low-cost, portable inherently safe rehabilitation robot is introduced. The robot is designed for use on existing table space in a home environment. Estimates of the robot's 2D position and orientation are computed by fusing data from two tracking systems, each utilizing a different sensor type: laser optical sensors and a webcam. Two laser optical sensors are mounted on the underside of the robot and track the relative motion of the robot with respect to the surface on which it is placed. The webcam is positioned directly above the workspace, mounted on a fixed stand, and tracks the robot's position with respect to a fixed coordinate system. The optical sensors sample the position data at a higher frequency than the webcam. A position and orientation fusion scheme is proposed to fuse the data from the two tracking systems. Active movements of a patient using the robot are assisted in real time by a custom-designed inherently safe guidance mechanism based on a COBOT unicycle architecture and capable of creating 2D virtual constraints. The guidance mechanism is mounted on the underside of the robot and in its centre, and is accompanied by four custom designed caster wheels with low rolling resistance. The guidance mechanism is actuated with a stepper motor, but no active force acting on the upper limb of the patient is generated. A prototype of the robot was manufactured and evaluated in a series of experiments including user testing with 38 healthy bodied adults. It was found that the robot is clearly capable of applying a passive force of suffcient magnitude and in the right direction to increase the accuracy with which able bodied adults can perform reaching arm movements. The resistance to movement of the robot, both friction and inertia are suffciently low that they do not appear to reduce the subjects' ability to move at normal reaching movement speeds."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/23344/1/Wojewoda_KK_Mechanical_PhD_2018.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["School of Mechanical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/23344/"],"dc:relation.references":["Amirabdollahian, F., Harwin, W. & Loureiro, R. (2007). Analysis of the fuglmeyer outcome measures assessing the e�ectiveness of robot-mediated stroke therapy. In Rehabilitation Robotics, 2007. ICORR 2007. IEEE 10th International Conference on, 729{735, IEEE. 42 Barnes, M.P. & Johnson, G.R. (2008). Upper motor neurone syndrome and spasticity: clinical management and neurophysiology. Cambridge University Press. 9, 10 Bill, G., Insurance, L., Insurance, T.I., Prescriptions, R., Prevention, C., Headstones, M., Certificates, M.P.M., Locator, N.G., Flags, B., Al- lowance, B. et al. (2011). Bilateral upper-limb rehabilitation after stroke using a movement-based game controller. 26, 27 Bradner, S. (1997). Key words for use in rfcs to indicate requirement levels. 69 Brookes, J., Kuznecovs, M., Kanakis, M., Grigals, A., Narvidas, M., Gal- lagher, J. & Levesley, M. (2017). Robots testing robots: Alan-arm, a humanoid arm for the testing of robotic rehabilitation systems. In Rehabilitation Robotics (ICORR), 2017 International Conference on, 676{681, IEEE. 114 Byl, N., Roderick, J., Mohamed, O., Hanny, M., Kotler, J., Smith, A., Tang, M. & Abrams, G. (2003). E�ectiveness of sensory and motor rehabilitation of the upper limb following the principles of neuroplasticity: patients stable poststroke. Neu- rorehabilitation and neural repair , 17, 176{191. 18 Cabral, N.L., Moro, C., Silva, G.R., Scola, R.H. & Werneck, L.C. (2003). Study comparing the stroke unit outcome and conventional ward treatment: a randomized study in joinville, brazil. Arquivos de neuro-psiquiatria, 61, 188{193. 10 205 REFERENCES Casadio, M., Sanguineti, V., Morasso, P.G. & Arrichiello, V. (2006). Braccio di ferro: a new haptic workstation for neuromotor rehabilitation. Technology and Health Care, 14, 123{142. xvi, 37, 38, 60 CCOHS (2008). What can workers do to reduce the discomfort of working in a standing position? http://www.ccohs.ca/oshanswers/ergonomics/standing/standing_ basic.html, accessed: 2014-09-25. xvii, 60, 61 Chua, J.Y. (2006). Design of a wearable cobot. xvi, xvii, 57, 58, 59 Cincura, C., Pontes-Neto, O.M., Neville, I.S., Mendes, H.F., Menezes, D.F., Mariano, D.C., Pereira, I.F., Teixeira, L.A., Jesus, P.A., de Queiroz, D.C. et al. (2009). Validation of the national institutes of health stroke scale, modi�ed rankin scale and barthel index in brazil: The role of cultural adaptation and structured interviewing. Cerebrovasc Dis, 27, 119{122. 10 Coote, S., Murphy, B., Harwin, W. & Stokes, E. (2008). The e�ect of the gentle/s robot-mediated therapy system on arm function after stroke. Clinical rehabilitation, 22, 395{405. 42 Culmer, P.R. (2007). Development of a Cooperative Robot System to Aid Stroke Reha- bilitation. Ph.D. thesis, University of Leeds. 8, 9, 10, 17, 18 Culmer, P.R., Levesley, M.C., Mon-Williams, M. & Williams, J.H. (2009). A new tool for assessing human movement: the kinematic assessment tool. Journal of neuroscience methods, 184, 184{192. 119 Daly, J.J., Hogan, N., Perepezko, E.M., Krebs, H.I., Rogers, J.M., Goyal, K.S., Dohring, M.E., Fredrickson, E., Nethery, J. & Ruff, R.L. (2005). Response to upper-limb robotics and functional neuromuscular stimulation following stroke. Journal of rehabilitation research & development, 42. 54 Dietz, V., Nef, T. & Zev Rymer, W. (2012). Neurorehabilitation Technology. Springer. 33, 49 Directive, C. (1993). 93/42/eec of 14 june 1993 concerning medical devices. 61, 62, 70, 151 206 REFERENCES Dobkin, B.H. (2004). Strategies for stroke rehabilitation. The Lancet Neurology, 3, 528{ 536. 2 Elmenreich, W. (2007). A review on system architectures for sensor fusion applications. Software Technologies for Embedded and Ubiquitous Systems, 547{559. 110 EPP (2006). Workstation design. http://www.ccohs.ca/oshanswers/ergonomics/ standing/standing_basic.html, accessed: 2014-09-25. xvii, 60, 61 Fess, E., Gettle, K., Philips, C. & Robin, J. (2005). Hand and upper extremity splinting. 82 Feys, H., De Weerdt, W., Verbeke, G., Steck, G.C., Capiau, C., Kiekens, C., Dejaeger, E., Van Hoydonck, G., Vermeersch, G. & Cras, P. (2004). Early and repetitive stimulation of the arm can substantially improve the long-term outcome after stroke: a 5-year follow-up study of a randomized trial. Stroke, 35, 924{929. 17 Fischer, U., Baumgartner, A., Arnold, M., Nedeltchev, K., Gralla, J., Marco De Marchis, G., Kappeler, L., Mono, M.L., Brekenfeld, C., Schroth, G. et al. (2010). What is a minor stroke? Stroke, 41, 661{666. 8 Gallagher, J., Preston, N., Holt, R., Mon-Williams, M., Levesley, M. & Weightman, A. (2015). Assessment of upper limb movement with an autonomous robotic device in a school environment for children with cerebral palsy. In Rehabilitation Robotics (ICORR), 2015 IEEE International Conference on, 770{774, IEEE. 114 Gillen, G. (2010). Stroke rehabilitation: a function-based approach. Elsevier Health Sciences. 7 Gillespie, R.B., Colgate, J.E. & Peshkin, M.A. (2001). A general framework for cobot control. Robotics and Automation, IEEE Transactions on, 17, 391{401. 56 Gladstone, D.J., Danells, C.J. & Black, S.E. (2002). The fugl-meyer assessment of motor recovery after stroke: a critical review of its measurement properties. Neurore- habilitation and neural repair , 16, 232{240. xxv, 8, 12, 13, 14 207 REFERENCES He, J., Koeneman, E., Schultz, R., Huang, H., Wanberg, J., Herring, D., Sugar, T., Herman, R. & Koeneman, J. (2005). Design of a robotic upper extremity repetitive therapy device. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 95{98, IEEE. xvi, 52 Herder, J. (2005). Development of a statically balanced arm support: Armon. In Re- habilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 281{286, IEEE. 36 Herder, J.L., Vrijlandt, N., Antonides, T., Cloosterman, M., Mastenbroek, P.L. et al. (2006). Principle and design of a mobile arm support for people with muscular weakness. Journal of rehabilitation research and development, 43, 591. 36 Hesse, S., Schulte-Tigges, G., Konrad, M., Bardeleben, A. & Werner, C. (2003). Robot-assisted arm trainer for the passive and active practice of bilateral forearm and wrist movements in hemiparetic subjects. Archives of physical medicine and rehabilitation, 84, 915{920. xv, 30, 31 Hesse, S., Schmidt, H., Werner, C., Rybski, C., Puzich, U. & Bardeleben, A. (2007). A new mechanical arm trainer to intensify the upper limb rehabilitation of severely a�ected patients after stroke: design, concept and �rst case series. Europa medicophysica, 43, 463{468. 31 Housman, S.J., Le, V., Rahman, T., Sanchez, R.J. & Reinkensmeyer, D.J. (2007). Arm-training with t-wrex after chronic stroke: preliminary results of a randomized controlled trial. In Rehabilitation Robotics, 2007. ICORR 2007. IEEE 10th International Conference on, 562{568, IEEE. 49 Housman, S.J., Scott, K.M. & Reinkensmeyer, D.J. (2009). A randomized controlled trial of gravity-supported, computer-enhanced arm exercise for individuals with severe hemiparesis. Neurorehabilitation and neural repair . 16, 20, 49 Howard, V.J., McClure, L.A., Meschia, J.F., Pulley, L., Orr, S.C. & Friday, G.H. (2006). High prevalence of stroke symptoms among persons without a diagnosis of stroke or transient ischemic attack in a general population: the reasons for geographic and racial di�erences in stroke (regards) study. Archives of internal medicine, 166, 1952{1958. 8 208 REFERENCES Jackson, A., Levesley, M., Makower, S., Cozens, J. & Bhakta, B. (2013). Development of the ipam mkii system and description of a randomized control trial with acute stroke patients. In IEEE... International Conference on Rehabilitation Robotics:[proceedings], vol. 2013, 6650407{6650407. xvi, 44, 45 Jahanshahloo, G.R., Lotfi, F.H. & Izadikhah, M. (2006). An algorithmic method to extend topsis for decision-making problems with interval data. Applied mathematics and computation, 175, 1375{1384. xxv, 75, 76 Johnson, M., Van der Loos, H., Burgar, C. & Leifer, L. (1999). Driver's seat: simulation environment for arm therapy. In Proceedings of the 6th International Con- ference on Rehabilitation Robotics (ICORR'99), Stanford, CA, US. xvi, 39, 40 Johnson, M., Wisneski, K., Anderson, J., Nathan, D. & Smith, R. (2006). Development of adler: The activities of daily living exercise robot. In Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on, 881{886, IEEE. 42 Kim, Y.S., Lee, J., Lee, S. & Kim, M. (2005). A force re ected exoskeleton-type masterarm for human-robot interaction. Systems, Man and Cybernetics, Part A: Systems and Humans, IEEE Transactions on, 35, 198{212. xvi, 48, 49 Knecht, S., Hesse, S. & Oster, P. (2011). Rehabilitation after stroke. Deutsches � Arzteblatt International, 108, 600. 15 Kowalczewski, J., Ravid, E. & Prochazka, A. (2011). Fully-automated test of upper-extremity function. In Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE, 7332{7335, IEEE. 19, 33 Krakauer, J.W. (2006). Motor learning: its relevance to stroke recovery and neurorehabilitation. Current opinion in neurology, 19, 84{90. 63 Krebs, H.I., Volpe, B.T., Williams, D., Celestino, J., Charles, S.K., Lynch, D. & Hogan, N. (2007). Robot-aided neurorehabilitation: a robot for wrist rehabilitation. Neural Systems and Rehabilitation Engineering, IEEE Transactions on, 15, 327{335. 44 209 REFERENCES Kwakkel, G. & Meskers, C.G. (2014). E�ects of robotic therapy of the arm after stroke. The Lancet Neurology, 13, 132{133. 19, 51, 63, 126 Kwakkel, G., Wagenaar, R.C., Twisk, J.W., Lankhorst, G.J. & Koetsier, J.C. (1999). Intensity of leg and arm training after primary middle-cerebral-artery stroke: a randomised trial. The Lancet, 354, 191{196. xv, 1, 16, 17 Kwakkel, G., Kollen, B.J. & Krebs, H.I. (2008). E�ects of robot-assisted therapy on upper limb recovery after stroke: a systematic review. Neurorehabilitation and neural repair , 22, 111{121. 18, 53, 54, 55 Langhorne, P., Bernhardt, J. & Kwakkel, G. (2011). Stroke rehabilitation. The Lancet, 377, 1693{1702. 16 Lawrence, E.S., Coshall, C., Dundas, R., Stewart, J., Rudd, A.G., Howard, R. & Wolfe, C.D. (2001). Estimates of the prevalence of acute stroke impairments and disability in a multiethnic population. Stroke, 32, 1279{1284. 8 Levin, M.F., Sveistrup, H. & Subramanian, S. (2010). Feedback and virtual environments for motor learning and rehabilitation. Schedae, 1, 19{36. 16, 17 Lo, A.C., Guarino, P.D., Richards, L.G., Haselkorn, J.K., Wittenberg, G.F., Federman, D.G., Ringer, R.J., Wagner, T.H., Krebs, H.I., Volpe, B.T. et al. (2010). Robot-assisted therapy for long-term upper-limb impairment after stroke. New England Journal of Medicine, 362, 1772{1783. 1, 8, 54, 55 Loureiro, R.C., Harwin, W.S., Nagai, K. & Johnson, M. (2011). Advances in upper limb stroke rehabilitation: a technology push. Medical & biological engineering & computing, 49, 1103{1118. 2, 18, 19, 20, 42, 46, 53, 54, 55, 62, 63 Lum, P., Burgar, C.G., Van der Loos, M., Shor, P., Majmundar, M. & Yap, R. (2005). The mime robotic system for upper-limb neuro-rehabilitation: results from a clinical trial in subacute stroke. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 511{514, IEEE. xvi, 44, 45 Luo, D., Schauer, T., Roth, M. & Raisch, J. (2012). Position and orientation control of an omni-directional mobile rehabilitation robot. In Control Applications (CCA), 2012 IEEE International Conference on, 50{56, IEEE. 26, 80, 93, 111, 125 210 REFERENCES Masory, O. & Sanroma, O. (2013). Upper-limbs rehabilitation devices part ii-passive devices. In RESNA ANNUAL CONFERENCE, RESNA. 34 Montagner, A., Frisoli, A., Borelli, L., Procopio, C., Bergamasco, M., Car- boncini, M.C. & Rossi, B. (2007). A pilot clinical study on robotic assisted rehabilitation in vr with an arm exoskeleton device. In Virtual Rehabilitation, 2007 , 57{64, IEEE. xvi, 51 Morse, A. & General, A. (2010). Progress in improving stroke care. 1 Nef, T. & Riener, R. (2005). Armin-design of a novel arm rehabilitation robot. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 57{60, IEEE. 16, 19, 47, 50 Nef, T., Mihelj, M., Colombo, G. & Riener, R. (2006). Armin-robot for rehabilitation of the upper extremities. In Robotics and Automation, 2006. ICRA 2006. Proceedings 2006 IEEE International Conference on, 3152{3157, IEEE. 51 Nef, T., Mihelj, M. & Riener, R. (2007). Armin: a robot for patient-cooperative arm therapy. Medical & biological engineering & computing, 45, 887{900. xvi, 51 Nicosevici, T., Garcia, R., Carreras, M. & Villanueva, M. (2004). A review of sensor fusion techniques for underwater vehicle navigation. In OCEANS'04. MTTS/IEEE TECHNO-OCEAN'04, vol. 3, 1600{1605, IEEE. 110 NINDS (2018). Nih stroke scale. https://www.ninds.nih.gov/sites/default/files/ NIH_Stroke_Scale_Booklet.pdf, accessed: 2018-12-30. 10 Norouzi-Gheidari, N., Archambault, P.S. & Fung, J. (2012). E�ects of robotassisted therapy on stroke rehabilitation in upper limbs: systematic review and metaanalysis of the literature. J Rehabil Res Dev, 49, 479{496. 1, 2 Organization, W.H. et al. (2011). World report on disability 2011. xv, 14, 15 Peattie, A., Korevaar, A., Wilson, J., Sandilands, B., Chen, X. & King, M. (2009). Automated variable resistance system for upper limb rehabilitation. Robotics and Automation. 24, 80, 92, 125 211 REFERENCES Perry, J.C., Zabaleta, H., Belloso, A., Rodr��guez-de Pablo, C., Cavallaro, F.I. & Keller, T. (2012). Armassist: development of a functional prototype for at-home telerehabilitation of post-stroke arm impairment. In Biomedical Robotics and Biomechatronics (BioRob), 2012 4th IEEE RAS & EMBS International Conference on, 1561{1566, IEEE. 22, 23, 70, 80, 92, 93, 122, 125 Peshkin, M. & Colgate, J.E. (1999). Cobots. Industrial Robot: An International Jour- nal, 26, 335{341. 57 Peshkin, M.A., Colgate, J.E., Wannasuphoprasit, W., Moore, C.A., Gille- spie, R.B. & Akella, P. (2001). Cobot architecture. Robotics and Automation, IEEE Transactions on, 17, 377{390. xvi, xvii, 56, 57, 58, 59 powerandsamplesize.com (2018). Calculate sample size needed to compare 2 means: 2- sample, 1-sided. http://powerandsamplesize.com/Calculators/Compare-2-Means/ 2-Sample-1-Sided, accessed: 2018-12-30. 189 Reinkensmeyer, D.J., Dewald, J.P. & Rymer, W.Z. (1999). Guidance-based quanti �cation of arm impairment following brain injury: a pilot study. Rehabilitation Engi- neering, IEEE Transactions on, 7, 1{11. xv, 35, 36 Reinkensmeyer, D.J., Kahn, L.E., Averbuch, M., McKenna-Cole, A., Schmit, B.D. & Rymer, W.Z. (2000). Understanding and treating arm movement impairment after chronic brain injury: progress with the arm guide. Journal of rehabilitation research and development, 37, 653{662. 36 Riener, R., Nef, T. & Colombo, G. (2005). Robot-aided neurorehabilitation of the upper extremities. Medical and Biological Engineering and Computing, 43, 2{10. 20, 43 Rohrer, B., Fasoli, S., Krebs, H.I., Hughes, R., Volpe, B., Frontera, W.R., Stein, J. & Hogan, N. (2002). Movement smoothness changes during stroke recovery. The Journal of Neuroscience, 22, 8297{8304. 94, 99 Rosamond, W.D., Gorton, R.A., Hinn, A.R., Hohenhaus, S.M. & Morris, D.L. (1998). Rapid response to stroke symptoms: the delay in accessing stroke healthcare (dash) study. Academic Emergency Medicine, 5, 45{51. 7 212 REFERENCES Sacco, R.L., Kasner, S.E., Broderick, J.P., Caplan, L.R., Culebras, A., Elkind, M.S., George, M.G., Hamdan, A.D., Higashida, R.T., Hoh, B.L. et al. (2013). An updated de�nition of stroke for the 21st century a statement for healthcare professionals from the american heart association/american stroke association. Stroke, 44, 2064{2089. 7 Sanchez Jr, R., Wolbrecht, E., Smith, R., Liu, J., Rao, S., Cramer, S., Rah- man, T., Bobrow, J. & Reinkensmeyer, D. (2005). A pneumatic robot for retraining arm movement after stroke: Rationale and mechanical design. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 500{504, IEEE. xvi, 52 Shah, S., Vanclay, F. & Cooper, B. (1989). Improving the sensitivity of the barthel index for stroke rehabilitation. Journal of clinical epidemiology, 42, 703{709. xxv, 10, 11, 12 Stienen, A.H., Hekman, E.E., Van der Helm, F.C., Prange, G.B., Jannink, M.J., Aalsma, A.M. & Van der Kooij, H. (2007a). Dampace: dynamic forcecoordination trainer for the upper extremities. In Rehabilitation Robotics, 2007. ICORR 2007. IEEE 10th International Conference on, 820{826, IEEE. 47 Stienen, A.H., Hekman, E.E., Van der Helm, F.C., Prange, G.B., Jannink, M.J., Aalsma, A.M. & Van der Kooij, H. (2007b). Freebal: dedicated gravity compensation for the upper extremities. In Rehabilitation Robotics, 2007. ICORR 2007. IEEE 10th International Conference on, 804{808, IEEE. 39, 40 Stienen, A.H., Hekman, E.E., Prange, G.B., Jannink, M.J., Aalsma, A.M., van der Helm, F.C. & van der Kooij, H. (2009a). Dampace: Design of an exoskeleton for force-coordination training in upper-extremity rehabilitation. Journal of Medical Devices, 3, 031003. 47 Stienen, A.H., Hekman, E.E., Prange, G.B., Jannink, M.J., van der Helm, F.C. & van der Kooij, H. (2009b). Freebal: design of a dedicated weight-support system for upper-extremity rehabilitation. Journal of Medical Devices, 3, 041009. 40 Stienen, A.H.A. (2009). Development of novel devices for upper-extremity rehabilitation. University of Twente. 43 213 REFERENCES Sukal, T.M., Ellis, M.D. & Dewald, J.P. (2005). Dynamic characterization of upper limb discoordination following hemiparetic stroke. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 519{521, IEEE. 42 Tomi�c, T.J.D., Savi�c, A.M., Vidakovi�c, A.S., Rodi�c, S.Z., Isakovi�c, M.S., Rodr��guez-de Pablo, C., Keller, T. & Konstantinovi�c, L.M. (2017). Armassist robotic system versus matched conventional therapy for poststroke upper limb rehabilitation: a randomized clinical trial. BioMed research international, 2017. 56 Toth, A., Fazekas, G., Arz, G., Jurak, M. & Horvath, M. (2005). Passive robotic movement therapy of the spastic hemiparetic arm with reharob: report of the �rst clinical test and the follow-up system improvement. In Rehabilitation Robotics, 2005. ICORR 2005. 9th International Conference on, 127{130, IEEE. xvi, 44, 45 van Delden, A., Peper, C.L.E., Kwakkel, G. & Beek, P.J. (2012). A systematic review of bilateral upper limb training devices for poststroke rehabilitation. Stroke research and treatment, 2012. 28, 29, 31, 32 van Delden, A.L.E., Peper, C.L.E., Harlaar, J., Daffertshofer, A., Zijp, N.I., Nienhuys, K., Koppe, P., Kwakkel, G. & Beek, P.J. (2009). Comparing unilateral and bilateral upper limb training: the ultra-stroke program design. BMC neurology, 9, 57. 29 Veerbeek, J.M., Langbroek-Amersfoort, A.C., Van Wegen, E.E., Meskers, C.G. & Kwakkel, G. (2017). E�ects of robot-assisted therapy for the upper limb after stroke: a systematic review and meta-analysis. Neurorehabilitation and neural repair , 31, 107{121. 53, 55, 62, 63 Wannasuphoprasit, W. (1999). Cobots: Collaborative robots. ProQuest Dissertations and Theses, 1{13. 57 Wannasuphoprasit, W., Gillespie, R.B., Colgate, J.E. & Peshkin, M.A. (1997). Cobot control. In Robotics and Automation, 1997. Proceedings., 1997 IEEE Interna- tional Conference on, vol. 4, 3571{3576, IEEE. 56 Welch, G. & Bishop, G. (1995). An introduction to the kalman �lter. university of north carolina, department of computer science. Tech. rep., TR 95-041. 97 214 REFERENCES Wojewoda, K., Culmer, P., Gallagher, J., Jackson, A. & Levesley, M. (2017). Hybrid position and orientation tracking for a passive rehabilitation table-top robot. In Rehabilitation Robotics (ICORR), 2017 International Conference on, 702{707, IEEE. 196 Wojewoda, K.K., Culmer, P.R., Jackson, A.E. & Levesley, M.C. (2016). Position tracking of a passive rehabilitation robot. In Cyber Technology in Automation, Control, and Intelligent Systems (CYBER), 2016 IEEE International Conference on, 1{6, IEEE. 116, 119, 121, 196 Wong, C.K., Jordan, K. & King, M. (2011). Robotic arm skate for stroke rehabilitation. In Rehabilitation Robotics (ICORR), 2011 IEEE International Conference on, 1{6, IEEE. 25, 80, 93, 125 Zabaleta, H., Valencia, D., Perry, J., Veneman, J. & Keller, T. (2011). Absolute position calculation for a desktop mobile rehabilitation robot based on three optical mouse sensors. In Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE, 2069{2072, IEEE. 92"],"dcterms:accessrights":["public"],"dc:title":["Passive Robotics for Accelerated Collaborative Therapy"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:31:49Z"}