{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:24128"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:24128","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Development of a novel 3D in vitro model to measure cellular response to antioxidant doped highly cross-linked ultra high molecular weight polyethylene wear debris","abstract":"Osteolysis, and subsequent aseptic loosening, is the leading cause of revision in total hip replacements. The biological response to ultra-high molecular weight polyethylene (UHMWPE) wear debris is known to trigger the release of several inflammatory mediators such as tumour necrosis factor-alpha (TNF-α), interleukin-1β (IL-1β), interleukin-6 (IL-6), interleukin-8 (IL-8), leukotriene B4 (LTB4) and prostaglandin E2 (PGE2); all of which are involved in the signalling cascade that triggers the differentiation of osteoclasts and begins osteolysis. UHMWPE has undergone modifications such as cross-linking (to reduce the volume of wear debris produced) and antioxidant doping (to neutralise free radicals produced by irradiative crosslinking and prevent oxidative embrittlement). Previous studies at the University of Leeds, using peripheral blood mononuclear cells (PBMNCs) cultured on wear particle containing agarose gel, have shown that antioxidant doped, highly cross-linked UHMWPE may reduce the production of osteolytic cytokines in comparison to highly cross-linked UHMWPE. This model has limitations; namely donor heterogeneity associated with the use of PBMNC’s in addition to the use of a 2D model for what is a 3D in vivo environment. The aims of this study were to develop a novel 3D model in which mononuclear phagocytes and wear particles were encapsulated within a gel and to use the model to compare the cellular production of osteolytic cytokines when treated with highly cross-linked UHMWPE and antioxidant doped, highly cross-linked UHMWPE wear debris. Three different cell types (PBMNC’s, U937 human histiocytes and RAW 264.7 murine macrophages) and two gel types (agarose and type I rat tail collagen) were investigated during the development of the 3D model. It was found that the use of RAW 264.7 murine macrophages and UHMWPE wear debris simultaneously trapped inside a collagen gel matrix was the most promising model. A large volume of sterile highly cross-linked UHMWPE wear debris (with and without antioxidant doping) was generated using pin-on-plate (POP) multidirectional wear simulator rigs for use in the 3D model. RAW 264.7 murine macrophages were cultured with both unfractionated UHMWPE wear debris, or a filtered, critical size range (0.1 – 1 μm) of UHMWPE wear debris. RAW 264.7 murine macrophages cultured in the 3D model with unfractionated UHMWPE wear debris showed no difference in oxidative stress levels or TNF-α, IL-1β, IL-6, KC (CXCL-1 – a murine homologue of IL-8), LTB4 and PGE2 levels produced in response to highly cross-linked UHMWPE wear debris with and without antioxidant doping compared to the cells only controls. Similarly, RAW 264.7 murine macrophages cultured in the 3D model with a critical size range (0.1 – 1 μm) of UHMWPE wear debris showed no difference in oxidative stress levels or TNF-α, IL-1β, IL-6, KC, LTB4 and PGE2 levels when treated with highly cross-linked UHMWPE wear debris with and without antioxidant doping compared to the cells only controls. RAW 264.7 murine macrophages were also stimulated with LPS in the 3D model and then treated with Protein Kinase C (PKC) inhibitors (Calphostin C and Bisindolylmaleimide I), 5-lipoxygenase (5-LO) inhibitors (MK 886 and REV 5901), Cycloxygenase (COX) inhibitor (Indomethacin) and antioxidants (α –tocopherol and pentaerythritol tetrakis(3,5-di-tert-butyl-4-hydroxyhydrocinnamate)) after three hours. RAW 264.7 murine macrophages treated with both PKC inhibitors and both antioxidants showed reduced levels of TNF-α and IL-6 when compared to the LPS only control. All inhibitors and antioxidants reduced the production of IL-1β when compared to the LPS only control. Cells treated with Calphostin C exhibited a reduced production of LTB4 and PGE2 when compared to the LPS only control. Microscopy images of RAW 264.7 murine macrophages cultured in the novel 3D model incubated with 0.1 – 1 μm antioxidant doped, highly cross-linked UHMWPE wear debris and FluoSpheres® showed that the RAW 264.7 murine macrophages sequestered the UHMWPE wear debris in the perinuclear lysosomes, indicating attempted phagocytosis, which is consistent with the previous studies. Overall, the RAW 264.7 murine macrophages cultured in the novel 3D model largely failed to produce inflammatory and osteolytic cytokines, chemokines and mediators in response to the UHMWPE wear debris generated in this study. However the novel model showed some promise by demonstrating the link between vitamin E and PKC in reducing the production of inflammatory and osteolytic mediators as shown in previous studies. The novel culture model requires further work to produce a more accurate in vitro representation of the 3D periprosthetic environment for use in future studies.","abstract_html":"Osteolysis, and subsequent aseptic loosening, is the leading cause of revision in total hip replacements. The biological response to ultra-high molecular weight polyethylene (UHMWPE) wear debris is known to trigger the release of several inflammatory mediators such as tumour necrosis factor-alpha (TNF-α), interleukin-1β (IL-1β), interleukin-6 (IL-6), interleukin-8 (IL-8), leukotriene B4 (LTB4) and prostaglandin E2 (PGE2); all of which are involved in the signalling cascade that triggers the differentiation of osteoclasts and begins osteolysis. UHMWPE has undergone modifications such as cross-linking (to reduce the volume of wear debris produced) and antioxidant doping (to neutralise free radicals produced by irradiative crosslinking and prevent oxidative embrittlement). Previous studies at the University of Leeds, using peripheral blood mononuclear cells (PBMNCs) cultured on wear particle containing agarose gel, have shown that antioxidant doped, highly cross-linked UHMWPE may reduce the production of osteolytic cytokines in comparison to highly cross-linked UHMWPE. This model has limitations; namely donor heterogeneity associated with the use of PBMNC’s in addition to the use of a 2D model for what is a 3D in vivo environment. The aims of this study were to develop a novel 3D model in which mononuclear phagocytes and wear particles were encapsulated within a gel and to use the model to compare the cellular production of osteolytic cytokines when treated with highly cross-linked UHMWPE and antioxidant doped, highly cross-linked UHMWPE wear debris. Three different cell types (PBMNC’s, U937 human histiocytes and RAW 264.7 murine macrophages) and two gel types (agarose and type I rat tail collagen) were investigated during the development of the 3D model. It was found that the use of RAW 264.7 murine macrophages and UHMWPE wear debris simultaneously trapped inside a collagen gel matrix was the most promising model. A large volume of sterile highly cross-linked UHMWPE wear debris (with and without antioxidant doping) was generated using pin-on-plate (POP) multidirectional wear simulator rigs for use in the 3D model. RAW 264.7 murine macrophages were cultured with both unfractionated UHMWPE wear debris, or a filtered, critical size range (0.1 – 1 μm) of UHMWPE wear debris. RAW 264.7 murine macrophages cultured in the 3D model with unfractionated UHMWPE wear debris showed no difference in oxidative stress levels or TNF-α, IL-1β, IL-6, KC (CXCL-1 – a murine homologue of IL-8), LTB4 and PGE2 levels produced in response to highly cross-linked UHMWPE wear debris with and without antioxidant doping compared to the cells only controls. Similarly, RAW 264.7 murine macrophages cultured in the 3D model with a critical size range (0.1 – 1 μm) of UHMWPE wear debris showed no difference in oxidative stress levels or TNF-α, IL-1β, IL-6, KC, LTB4 and PGE2 levels when treated with highly cross-linked UHMWPE wear debris with and without antioxidant doping compared to the cells only controls. RAW 264.7 murine macrophages were also stimulated with LPS in the 3D model and then treated with Protein Kinase C (PKC) inhibitors (Calphostin C and Bisindolylmaleimide I), 5-lipoxygenase (5-LO) inhibitors (MK 886 and REV 5901), Cycloxygenase (COX) inhibitor (Indomethacin) and antioxidants (α –tocopherol and pentaerythritol tetrakis(3,5-di-tert-butyl-4-hydroxyhydrocinnamate)) after three hours. RAW 264.7 murine macrophages treated with both PKC inhibitors and both antioxidants showed reduced levels of TNF-α and IL-6 when compared to the LPS only control. All inhibitors and antioxidants reduced the production of IL-1β when compared to the LPS only control. Cells treated with Calphostin C exhibited a reduced production of LTB4 and PGE2 when compared to the LPS only control. Microscopy images of RAW 264.7 murine macrophages cultured in the novel 3D model incubated with 0.1 – 1 μm antioxidant doped, highly cross-linked UHMWPE wear debris and FluoSpheres® showed that the RAW 264.7 murine macrophages sequestered the UHMWPE wear debris in the perinuclear lysosomes, indicating attempted phagocytosis, which is consistent with the previous studies. Overall, the RAW 264.7 murine macrophages cultured in the novel 3D model largely failed to produce inflammatory and osteolytic cytokines, chemokines and mediators in response to the UHMWPE wear debris generated in this study. However the novel model showed some promise by demonstrating the link between vitamin E and PKC in reducing the production of inflammatory and osteolytic mediators as shown in previous studies. The novel culture model requires further work to produce a more accurate in vitro representation of the 3D periprosthetic environment for use in future studies.","abstract_has_math":false,"creators":["Yarrow-Wright, Lauren Elizabeth"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Tipper, Joanne","Williams, Sophie","Hewitt, Eric"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-09","date_published":"2018-09","updated_at":"2026-11-18T22:33:12Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.778630"],"render_values":[{"text":"uk.bl.ethos.778630","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/24128/1/LYW%20final%20thesis%20240519.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A24128","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tipper, Joanne","Williams, Sophie","Hewitt, Eric"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC"]},{"key":"dc:creator","label":"Author","values":["Yarrow-Wright, Lauren Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-09-30"]},{"key":"dc:date.issued","label":"Date","values":["2018-09"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/24128/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["List of References Abildtrup, M., Kingsley, G. H. and Scott, D. L. 2015. Calprotectin as a biomarker for rheumatoid arthritis: a systematic review. The Journal Of Rheumatology. 42(5), p. 760–770. Affatato, S., Spinello, M., Zavalloni, M., Mazzega-Fabbro, C. and Viceconti, M. 2008). Tribology and total hip joint replacement: Current concepts in mechanical simulation. Medical Engineering And Physics. 30(10), p. 1305–1317. Anderson, D. E. and Johnstone, B. 2017. Dynamic Mechanical Compression of Chondrocytes for Tissue Engineering: A Critical Review. Frontiers In Bioengineering And Biotechnology. 5(December), p. 1–20. Anderson, J. M., Rodriguez, A. and Chang, D. T. 2008. Foreign body reaction to biomaterials. Seminars In Immunology. 20(2), pp. 86–100. Arden, N. and Nevitt, M. C. 2006. Osteoarthritis: Epidemiology. Best Practice And Research: Clinical Rheumatology. 20(1), p. 3–25. Arend, W. P. 1995. Inhibiting the effects of cytokines in human diseases. Advances In Internal Medicine. 40, p. 365 – 394. De Bandt, M., Grossin, M., Driss, F., Pincemail, J., Bain-Chevaye, C. and Pasquier, C. 2002. Vitamin E uncouples joint destruction and clinical inflammation in a transgenic mouse model of rheumatoid arthritis. Arthritis And Rheumatism. 46(2), p. 522–532. Barbour, P. S. M. 1999. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 213(6), p. 455–467. Baxter, R. M. Steinbeck, M. J., Tipper, J. L., Parvizi, J., Marcolongo, M. and Kurtz, S. M. 2009. Comparison of periprosthetic tissue digestion methods for ultra-high molecular weight polyethylene wear debris extraction. Journal Of Biomedical Materials Research - Part B Applied Biomaterials. 91(1), p. 409–418. Bellare, A., Schnablegger, H., and Cohen, R. E. 1995. A small-angle x-ray scattering study of high-density polyethylene and ultra-high molecular weight polyethylene. Macromolecules, 17, p. 2325–2333. Bergschmidt, P., Bader, R., and Mittelmeier, W. 2012. Metal hypersensitivity in total knee arthroplasty: Revision surgery using a ceramic femoral component – a case report. The Knee. 19, p. 144 – 147. Berlin, J. A., Braithwaite, G. J. C., Knight, J., Pletcher, D. and Rufner, A. 2011. Oxidative Stability of Highly Crosslinked Vitamin E UHMWPE Blends in Extreme and Physiological Accelerated Aging Conditions. [Poster]. ORS 2011 Annual Meeting, 13 - 16th Jan, California. Besong , A.A., Hailey, J.L., Ingham, E., Stone, M., Wroblewski, B.M. and Fisher, J. 1997. A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE. Biomedical Materials And Engineering. 7(1), p. 59–65. Bichara, D. A., Malchau, E., Sillesen, N. H., Cakmak, S., Nielsen, G. P. and Muratoglu, O. K. 2014. Vitamin E-diffused highly cross-linked UHMWPE particles induce less osteolysis compared to highly cross-linked virgin UHMWPE particles in vivo. Journal Of Arthroplasty. 29(9 SUPPL.), p. 232–237. Birnkraut, H. W. 1991. Synthesis of UHMWPE. In Willert, H.G., Buchhorn, G.H., and Eyerer, P. eds. Ultra-high Molecular Weight Polyethylene As A Biomaterial In Orthopedic Surgery. Lewiston, New York: Hogrefe & Huber. Bladen, C. L., Teramura, S., Russell, S. L., Fujiwara, K., FIsher, J., Ingham, E., Tomita, N. and Tipper, J. L. 2013a. Analysis of wear, wear particles, and reduced inflammatory potential of vitamin e ultrahigh-molecular-weight polyethylene for use in total joint replacement. Journal Of Biomedical Materials Research - Part B Applied Biomaterials. 101 B(3), p. 458–466. Bladen, C. L., Tzu-Yin, L., FIshe, J. and Tipper, J. L. 2013b. In vitro analysis of the cytotoxic and anti-inflammatory effects of antioxidant compounds used as additives in ultra high-molecular weight polyethylene in total joint replacement components. Journal Of Biomedical Materials Research - Part B Applied Biomaterials. 101 B(3), p. 407–413. Bracco, P., Bellare, A., Bistolfi, A. and Affatato, S. 2017. Ultra-high molecular weight polyethylene: Influence of the chemical, physical and mechanical properties on the wear behavior. A review. Materials. 10(7), p. 791 - 813. Bracco, P. and Oral, E. 2011. Vitamin E-stabilized UHMWPE for total joint implants: A review. Clinical Orthopaedics And Related Research. 469(8), p. 2286–2293. Brach Del Prever, E.M., Bistolfi, A., Bracco, P. and Costa, L. 2009. UHMWPE for arthroplasty: past or future?. Journal Of Orthopaedics And Traumatology : Official Journal Of The Italian Society Of Orthopaedics And Traumatology. 10(1), p. 1–8. Brigelius-Flohé, R. and Traber, M. G. 1999. Vitamin E: function and metabolism. The FASEB Journal. 13(10), p. 1145–1155. Brooks, R. A., Wimhurst, J. A. and Rushton, N. 2002. Endotoxin contamination of particles produces misleading inflammatory cytokine responses from macrophages in vitro. The Journal Of Bone And Joint Surgery. British Volume. 84(2), p. 295–299. Brown, C., Fisher, J., and Ingham, E. 2006. Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 220(2), p. 355 – 369. Burton, G. W. 1990. Vitamin E: Antioxidant Activity, Biokinetics, And Bioavailability. Annual Review Of Nutrition. 10, p. 357 - 382. Callaghan, J. J., Templeton, J. E., Liu, S. S., Pedersen, D. R., Goetz, D. D., Sullivan, P. M., and Johnston, R. C. 2004. Results Of Charnley Total Hip Arthroplasty At A Minimum Of Thirty Years. The Journal Of Bone And Joint Surgery. American Volume. 86–A(4), p. 690–695. Campbell, P., Ma, S., Schmalzreid, T. and Amstutz, H. C. 1996. Tissue digestion for wear debris particle isolation. Journal Of Biomedical Materials Research. 29(10), p. 1393–1397. Catelas, I., Petit, A., Marchand, R., Zukor, D., Yahia, L., and Huk, O. 1999. Cytotoxicity and macrophage cytokine induced by ceramic and polyethylene particles in vitro. The Journal Of Bone And Joint Surgery. 81B(issue), p. 516 – 521. Charnley, J. 1961. Arthroplasty of hip – a new operation. Lancet, 1(7187), p. 1129–1132. Chiu, Y. G. and Ritchlin, C. T. 2017. Denosumab: targeting the RANKL pathway to treat rheumatoid arthritis. Expert Opinion On Biological Therapy. 17(1), p. 119–128. Cho, D. R., Shanbhag, A. S., Hong, C. Y., Baran, G. R. and Goldring, S. R. 2002. The role of adsorbed endotoxin in particle-induced stimulation of cytokine release. Journal Of Orthopaedic Research. 20(4), p. 704–713. Chumakov, M. 2009. Nitroxides as free radical scavengers in UHMWPE. [Poster]. 55th Annual Meeting of the Orthopaedic Research Society, 22-25th Feb, Las Vegas. Collier, J.P., Sperling, D.K., Currier, J.H., Sutula, L.C., Saum, K.A. and Mayor, M. B. 1996. Impact of gamma sterilization on clinical performance of polyethylene in the knee. The Journal Of Arthroplasty. 11(4), p. 377–389. Conner, E.M. and Grisham, M. B. 1996. Inflammation, free radicals, and antioxidants. Nutrition. 12(4), p. 247–277. Cooper, J. R., Dowson, D. and Fisher, J. 1993. Macroscopic and microscopic wear mechanisms molecular weight polyethylene in ultra-high. Wear. 162-164 (A), p. 378–384. Costa, A.G., Cusano, N.E., Silva, B.C., Cremers, S. and Bilezikian, J. P. 2011. Cathepsin K: its skeletal actions and role as a therapeutic target in osteoporosis. Nature Reviews Rheumatology. 7(8), p. 447–456. Costa, L. and Bracco, P. 2009. Mechanisms of Crosslinking, Oxidative Degradation and Stabilization of UHMWPE. In Kurtz, S. M. ed. UHMWPE Biomaterials Handbook. San Diego: Elsevier Academic Press Inc, pp. 309–323. Craig, R. Vlycou, M., McCArthy, C. L., Gibbons, C. L. M. H. and Athanasou, N. A. 2017. Metal wear-induced pseudotumour following an endoprosthetic knee replacement for Ewing sarcoma. Skeletal Radiology. 46(7), p. 967–974. Cummings, S. R., Kelsey, J.L., Nevitt, M. and O’Dowd, K. J. 1985. Epidemiology of osteoporosis and osteoporotic fractures. Australian Prescriber. 20(SUPPL. 3), p. 13–17. Devaraj, S. and Jialal, I. 1999. Alpha-Tocopherol Decreases Interleukin-1β Release From Activated Human Monocytes by Inhibition of 5-Lipoxygenase’. Arteriosclerosis, Thrombosis And Vascular Biology. 19(4), p. 1125 - 1133. Devaraj, S., Li, D. and Jialal, I. 1996. The effects of alpha tocopherol supplementation on monocyte function: Decreased lipid oxidation, interleukin 1β secretion, and monocyte adhesion to endothelium. Journal Of Clinical Investigation. 98(3), p. 756–763. Devine, T.M. and Wulff, J. 1975. Cast vs. wrought cobalt-chromium surgical implant alloys. Journal Of Biomedical Materials Research. 9(2), p. 151–67. Dolezel, B. and Adamirova, L. 1982. Method of hygienically safe stabilization of polyolefines against thermoxidative and photoxidative degradation. Czechislovakian Socialist Republic Patent, 221:403. Dorlot, J-M., Christel, P. and Meunier, A. 1989. Wear analysis of retrieved alumina heads and sockets of hip prostheses. Journal Of Biomedical Materials Research. 23(A3 suppl), p. 299–310. Duff, G. W. 1993. Cytokines and anti-cytokines. British Journal Of Rheumatology. 32(1), p. 15–20. Dumbleton, J. H., Manley, M. T. and Edidin, A. A. 2002. A literature review of the association between wear rate andosteolysis in total hip arthroplasty. Journal Of Arthroplasty. 17(5), p. 649 - 661. Edidin, A.A. and Kurtz, S. M. 2000. The influence of mechanical behavior on the wear of four clinically relevant polymeric biomaterials in a hip simulator. Journal Of Arthroplasty. 15(3), p. 321–331. Endo, M. M., Barbour, P. S., Barton, D. C., Fisher, J., Tipper, J. L., Ingham, E. and Stone, M. H. 2001. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene. Biomedical Materials And Engineering. 11(1), p. 23–35. Endo, M., TIpper, J. L., Barton, D. C., Stone, M. H., Ingham, E. and Fisher, J. 2002. Comparison of wear, wear debris, and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 216 (2), p. 111 - 122. Feldman, L.A. and Hui, H. K. 1997. Compatibility of medical devices and materials with low-temperature hydrogen peroxide gas plasma. Medical Device And Diagnostic Industry. 19(12), p. 57–62. Franzen, H., Carlsson, Å., Johnsson, R., Rydholm, A., Önnerfält, R. 1994. Bony atrophy after mega total hip replacement for bone tumors: 11 cases followed for 3-15 years. Acta Orthopaedica. 65(5), p. 513–516. Fröhlich, S. M., Dorrer, V., Archodoulaki, V-M., Allmaier, G. and Marchetti-Deschmann, M. 2014. Synovial fluid protein adsorption on polymer-based artificial hip joint material investigated by MALDI-TOF mass spectrometry imaging. EuPA Open Proteomics. 4(2014), pp. 70–80. Fu, J., Shen, J., Gao, G., Xu, Y., Hou, R., Cong, Y. and Cheng, Y. 2013. Natural polyphenol-stabilised highly crosslinked UHMWPE with high mechanical properties and low wear for joint implants. Journal Of Materials Chemistry B. 1(37), p. 4727–4735. Gallardo, L. A., Knowlton, C. B., Kunze, J., Jacobs, J. J., Wimmer, M. A. and Laurent, M. P. 2011a. Effect of europium(II) stearate on the mechanical properties and the oxidation resistance of UHMWPE. Journal Of The Mechanical Behavior Of Biomedical Materials. 4(5), p. 821–826. Gallardo, L. A., Carpentieri, I., Laurent, M. P., Costa, L. and Wimmer, M. A. 2011b. Europium stearate additives delay oxidation of UHMWPE for orthopaedic applications: A pilot study. Clinical Orthopaedics And Related Research. 469(8), p. 2294–2301. Galvin, A., Kang, L., Tipper, J., Stone, M., Ingham, E., Jin, Z. and Fisher, J. 2006. Wear of crosslinked polyethylene under different tribological conditions. Journal of Materials Science: Materials In Medicine. 17(3), p. 235–243. Germain, M., Hatton, A., Williams, S., Matthews, J. B., Stone, M. H., Fisher, J. and Ingham, E. 2003. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials. 24(3), p. 469 – 479. Gijsman, P., Smelt, H.J. and Schumann, D. 2010. Hindered amine light stabilizers: An alternative for radiation cross-linked UHMWPE implants. Biomaterials. 31(26), p. 6685–6691. Goldring, M. B. and Goldring, S. R. 2007. Osteoarthritis. Journal Of Cellular Physiology. 213(3), p. 626–634. Goode, A. E., Perkins, J. M., Sandison, A., Karunakaran, C., Cheng, H., Wall, D., Skinner, J. A., Hart, A. J., Porter, A. E., McComb, D. W. and Ryan, M. P. 2012. Chemical speciation of nanoparticles surrounding metal-on-metal hips. Chemical Communications. 48(67), p. 8335–8337. Goodman, S. M. 2013. Rheumatoid Arthritis Preoperative Evaluation for Total Hip and Total Knee Replacement Surgery. Journal Of Clinical Rheumatology. 19(4), p. 187–92. Gowland, N. 2014. The Wear and Biological Activity of Antioxidant UHMWPE for use in Total Hip Replacements. Ph.D. thesis, University of Leeds. Granchi, D., Cenni, E., Giunti, A., and Baldini, N. 2012. Metal hypersensitivity testing in patients undergoing joint replacement: a systematic review. The Journal Of Bone And Joint Surgery. 94B(8), p. 1126–1134. Granchi, D., Cennis, E., Trisolino, G., Giunti, A., and Baldini, N. 2006. Sensitivity to implant materials in patients undergoing total hip replacement. Journal Of Biomedical Material Research B: Applied Biomaterials. 77(2), p. 257 – 264. Gray, H. 2019a. Gray’s Anatomy: Hip anatomy. [online]. [Accessed: 22 April 2019]. Available from: https://upload.wikimedia.org/wikipedia/commons/f/f1/Gray339.png Gray, H. 2019b. Gray's Anatomy: Hip anatomy. [online]. [Accessed: 22 April 2019]. Available from: https://upload.wikimedia.org/wikipedia/commons/3/33/Gray340.png Gray, H. 2014a. Gray’s Anatomy. Pelvis anatomy. [online]. [Accessed: 31 August 2014]. Available from: http://upload.wikimedia.org/wikipedia/commons/9/98/Gray241.png Gray, H. 2014b. Grays Anatomy. Femoral head anatomy., online]. [Accessed: 31 August 2014]. Available from: http://upload.wikimedia.org/wikipedia/commons/9/97/Gray243.png Green, J.M., Hallab, N.J., Senyurt, A., Liao, P., O’Keefe, R.J., Schwarz, E.M. and Xie, C. 2012. Effects of anti-oxidation treatments during the manufacturing of ultra high molecular weight polyethylene prosthetic components on their osteolytic and osteogenic properties as wear debris particles in a murine calvaria model. Current Rheumatology Reports. 26(1951), p. 61307. Green, T. R., Fisher, J., Stone, M. H., Wroblewski, B. M and Ingham, E. 1998. Polyethylene particles of a “critical size” are necessary for the induction of cytokines by macrophages in vitro. Biomaterials. 19(24), p. 2297–2302. Green, T. R., Fisher, J., Matthews, J. B., Stone, M. H. and Ingham, E. 2000. Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. Journal Of Biomedical Materials Research. 53(5), p. 490–497. Han, K.H., Ryu, J.W., Lim, K.E., Lee, S.H., Kim, Y., Hwang, C.S., Choi, J. Y. and Han, K. O. 2014. Vascular expression of the chemokine CX3CL1 promotes osteoclast recruitment and exacerbates bone resorption in an irradiated murine model. Bone. 61, p. 91–101. Hannouche, D., Hamadouche, M., Nizard, W., Bizot, P., Meunier, A. and Sedel, L. 2005. Ceramics in total hip replacement. Clinical Orthopaedics And Related Research. Jan(430), p. 62–71. He, S., Le, K-P., Blitz, J.W., Yau, S-S., Korduba, L.A. and Wang, A. 2009. Anthocyanin doped UHMWPE : oxidation, wear and mechanical properties. [Poster]. 55th Annual Meeting of the Orthopaedic Research Society, 22-25th Feb, Las Vegas. He, S., Yau, S-S., Wang, A. and Lawrynowicz, D. E. 2012. Polyethylene Cross-linked With An Anthocyanin. Patent. US8133436B2. Holliday, L.S., Bubb, M.R., Jiang, J., Hurst, I.R. and Zuo, J. 2005. Interactions between vacuolar H+-ATPases and microfilaments in osteoclasts. Journal Of Bioenergetics And Biomembranes. 37(6), p. 419–423. Howling, G. I., Barnett, P. I., Tipper, J. L., Stone, M. H., Fisher, J. and Ingham, E. 2001. Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants. Journal Of Biomedical Materials Research. 58(4), p. 415–420. Inada, M., Wang, Y., Byrne, M.H., Miyaura, C. and Krane, S. M. 2003. The collagenase, matrix metalloproteinase-13 (MMP-13), is required for osteoclast formation and function. Journal Of Bone And Mineral Research. 18, p. 195. Ingham, E. and Fisher, J. 2000. Biological Reaction to Wear Debris in Total Joint Replacement. Proceedings Of The Institution Of Mechanical Engineers. Part H. 73(2), p. 21–37. Ingham, E. and Fisher, J. 2005. The role of macrophages in osteolysis of total joint replacement. Biomaterials. 26(11), p. 1271–1286. Ingram, J. H., Stone, M. H., Fisher, J. and Ingham, E. 2004. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles. Biomaterials. 25(17), p. 3511–3522. Isaac, G. H., Dowson, D. and Wroblewski, B. M. 1996. An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups-wear, creep or degradation ? Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 210(3), p. 209–216. Jacobsen, S., Rømer, L., and Søballe, R. 2006. The other hip in unilateral hip dysplasia. Clinical Orthopaedics And Related Research. 446, p. 239 – 246. Jahan, M.S., Wang, C., Schwartz, G. and Davidson, J. A. 1991. Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation. Journal Of Biomedical Materials Research. 25(8), p. 1005–1017. James, S.P., Oldinski, R., Zhang, M. and Schwartz, H. 2016. UHMWPE-hyaluronan microcomposite biomaterials. In: Kurtz, S. Ultrahigh Molecular Weight Polyethylene In Total Joint Replacements And Medical Devices. San Diego: Elsevier academic press, p. 352 – 368. Janeway, C. A., Travers, P., Walport, M. and Schlomchik, M. J. 2001. Immunobiology. 5th Edition. New York: Garland Science. Jarrett, B. T., Cofske, J., Rosenberg, A. E., Oral, E., Muratoglu, O., and Malchau, H. 2010. In Vivo Biological Response to Vitamin E and Vitamin-E-Doped Polyethylene. The Journal Of Bone And Joint Surgery American Volume. 92A(16), p. 2672–2681. Jazrawi, L. M., Bogner, E., Della Valle, C. J., Chen, F. S., Pak, K. I., Stuchin, S. A., Frankel, V. H., and Di Cesare, P. E. 1999. Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants. A 12-year follow-up study. The Journal Of Arthroplasty. 12(7), p. 781 - 787. Kannu, P. and Howard, A. 2014. Perthes’ disease. British Medical Journal. 349, p.5584. Khan, H., Riva, F., Presacco, M., Meswania, J., Panagiotidou, A., Coathup, M., and Blunn, G. W. 2018. Development of the Lima ceramic hip resurfacing system: revision of hip resurfacing using a dual taper ceramic head and taper adaptor in an in vitro model. Orthopaedic Proceedings. 99B(4), p.61 Kim, M.S., Day, C.J. and Morrison, N. A. 2005. MCP-1 is induced by receptor activator of nuclear factor-kappa B ligand, promotes human osteoclast fusion, and rescues granulocyte macrophage colony-stimulating factor suppression of osteoclast formation. Journal Of Biological Chemistry. 280(16), p. 16163–16169. Kim, K., Lee, S-H., Kim, J. H., Choi, Y. and Kim, N. 2006. NFATc1 induces osteoclast fusion via up-regulation of osteoclast fusion and increased bone formation. Nature Medicine. 12, p. 1403–1409. Kim, Y., Sato, K., Asagiri, M., Morita, I., Soma, K. and Takayanagi, H. 2005. Contribution of nuclear factor of activated T cells c1 to the transcriptional control of immunoreceptor osteoclast-associated receptor but not triggering receptor expressed by myeloid cells-2 during osteoclastogenesis. Journal Of Biological Chemistry. 280(38), p. 32905–32913. King, R; Arscott, E and Narayan, V. 2010. Biocompatibility Study of Gamma-irradiated UHMWPE Stabilized with a Hindered-Phenol Antioxidant. [Poster]. 56th Annual Meeting of the Orthopaedic Research Society, 6th-9th Mar, New Orleans, Louisiana. Klaue, K., Durnin, C.W. and Ganz, R. 1991. The acetabular rim syndrome - a clinical presentation of dysplasia of the hip. Journal Of Bone And Joint Surgery - British Volume. 73(3), p. 423–429. Koureas, G., Wicart, P., and Serine, R. 2007. Etiology of developmental hip dysplasia or dislocation: review article. HIP International. 17(5), p. 1–7. Kurtz, S.M., Muratoglu, O.K., Evans, M. and Edidin, A. A. 1999. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials. 20(issue), p. 1659–1688. Kurtz, S. 2004a. Chapter 1: A primer on UHMWPE. Kurtz, S. Ed. The UHMWPE Handbook. San Diego: Elsevier academic press, p. 1 - 12. Kurtz, S. 2004b. Chapter 2: From ethylene gas to UHMWPE component: the process of producing orthopedic implants. Kurtz, S. Ed. The UHMWPE Handbook. San Diego: Elsevier academic press, p. 13 - 36. Kurtz, S. 2004c. Chapter 3: Packaging and sterilzation of UHMWPE. Kurtz, S. Ed. The UHMWPE Handbook. San Diego: Elsevier academic press, p. 37 - 51. Kyomoto, M., Moro, T. and Ishihara, K. 2016. Phospholipid polymer grafted highly cross-linked UHMWPE. In: Kurtz, S. ed. Ultrahigh molecular weight polyethylene in total joint replacements and medical device. 3rd Edition. San Diego: Elsevier academic Press, p. 352 – 368. Lancaster, J. G., Dowson, D., Isaac, G. H. and Fisher, J. 1997. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 211(1), p. 17–24. Laslo P, Spooner CJ, Warmflash A, Lancki DW, Lee HJ, Sciammas R, Gantner, B. N., Dinner, A. R. and Singh, H. 2006. Multilineage transcriptional priming and determination of alternate hematopoietic cell fates. Cell. 126(4), p. 755–766. Lee, D. M. and Weinblatt, M. E. 2001. Rheumatoid arthritis. Lancet. 358(9285), p. 903–911. Lee, H. 2016. Spinal Cord Cellular Response To Wear Debris From Metal-on-Metal Total Disc Replacements. Ph.D. thesis, University of Leeds. Liu, A. 2012. Determination of the biological response and cellular uptake mechanisms of nanometre-sized UHMWPE wear particles from total hip replacements. Ph.D. thesis, University of Leeds. Liu, A., Richards, L., Bladen, C. L., Ingham, E., Fisher, J. and Tipper, J. L. 2015. The biological response to nanometre-sized polymer particles. Acta Biomaterialia. 23, p. 38 - 51. Malik, J., Hrivik, A. and Tomova, E. 1992. Diffusion of hindered amine light stabilizers in low-density polyethylene and isotactic polypropylene. Polymer Degradation And Stability. 35(1), p. 61–66. Man, G. S. and Mologhianu, G. 2014. Osteoarthritis pathogenesis - a complex process that involves the entire joint. Journal Of Medicine And Life. 7(1), p. 37–41. Margevicius, K. J., Bauer, T. W., McMahon, J. T., Brown, S. A. and Merritt, K. 1994. Isolation and characterization of debris in membranes around total joint prostheses. Journal Of Bone And Joint Surgery - Series A. 76(11), p. 1664–1675. Martell, J., Berkson, E. and Jacobs, J. J. 2000. The performance of 2D vs. 3D computerized wear analysis in the Harris Galante acetabular component. Orthopaedic Transactions. 25(564), p. 88. Matsumoto, M., Kogawa, M., Wada, S., Takayanagi, H., Tsujimoto, M., Katayama, S., Hisatake, K. and Nogi, Y. 2004. Essential role of p38 mitogen-activated protein kinase in cathepsin K gene expression during osteoclastogenesis through association of NFATc1 and PU.1. Journal Of Biological Chemistry. 279(44), p. 45969–45979. Matsusaki, T., Kawanabe, K., Ise, K., Nakayama, T., Toguchida, J., and Nakamura, T. Gene Expression Profile of Macrophage-Like U937 Cells in Response to Polyethylene Particles. A Novel Cell-Particle Culture System. Journal Of Arthroplasty. 22(7), p. 960–965. Matthews, J. B., Green, T. R., Stone, M. H., Wroblewski, B. M., Fisher, J. and Ingham, E. 2000a. Comparison of the response of primary human peripheral blood mononuclear phagocytes from different donors to challenge with model polyethylene particles of known size and dose. Biomaterials. 21(20), p. 2033–2044. Matthews, J. B., Green, T. R., Stone, M. H.,Wroblewski, B. M., Fisher, J. and Ingham, E. 2000c. Comparison of the response of primary murine peritoneal macrophages and the U937 human histiocytic cell line to challenge with in vitro generated clinically relevant UHMWPE particles. Biomedical Materials And Engineering. 10(3–4), p. 229–240. Matthews, J. B., Besong, A. A., Green, T. R., Stone, M. H., Wroblewski, B. M., Fisher, J. and Ingham, E. 2000b. Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose. Journal Of Biomedical Materials Research. 52(2), p. 296–307. Matthews, J. B., Green, T. R., Stone, M. H., Wroblewski, B. M., FIsher, J .and Ingham, E. 2001. Comparison of the response of three human monocytic cell lines to challenge with polyethylene particles of known size and dose. Journal Of Materials Science: Materials n Medicine. 12(3), p. 249–258. McGill, I. 2005. Rare Earth Elements. Weinheim: Wiley-VCH. McKellop, H., Shen, F., Lu, B., Campbell, P. and Salovey, R. 1999. Development of an extremely wear-resistant ultra high molecular weight polythylene for total hip replacements. Journal Of Orthopaedic Research. 17(2), p. 157–167. Medley , J.B., Chan, F.W., Krygier, J.J. and Bobyn, J. D. 1996. Comparison of alloys and designs in a hip simulator study of metal on metal implants. Clinical Orthopaedics And Related Research. Aug(329 Suppl), p. 148-159. Menaa, C., Kurihara, N., and Roodman, G. D. 2000. CFU-GM-derived cells form osteoclasts at a very high efficiency. Biochemical And Biophysical Research Communications. 267(3), p. 943–946. Mercier, C. and Chabardes, P. 1994. Organometallic chemistry in industrial vitamin-a and vitamin-e synthesis. Pure And Applied Chemistry. 66(7), p. 1509–1518. Milosev, I., Kovac, S., Topolovec, M., Pisot, V. and Trebse, R. 2009. Total hip replacements with metal-on-metal bearings. Zdravniski Vestnik. 78(Supp. II), p. 34–40. Minkara, A.A., Westermann, R.W., Rosneck, J. and Lynch, T. S. 2018. Systematic review and meta-analysis of outcomes after hip arthroscopy in femoralacetabular impingement. American Journal Of Sports Medicine. Jan(1), p.036354651774947. Miyamoto , T., Ohneda, O., Arai, F., Iwamoto, K., Okada, S., Takagi, K., Anderson, D. M. and Suda, T. 2001. Bifurcation of osteoclasts and dendritic cells from common progenitors. Blood. 98(8), p. 2544–2554. Molini, L., Precerutti, M., Gervasio, A., Draghi, F. and Bianchi, S. 2011. Hip: Anatomy and US technique. Journal Of Ultrasound. 14(2), p. 99–108. Mont, M.A. and Hungerford, D. S. 1995. Nontraumatic avascular necrosis of the femoral-head. Journal Of Bone And Joint Surgery: American Volume.. 77A(3), p. 459–474. Mont, M., Ragland, P. S., Etienne, G., Seyler, T. M. and Schmalzried, T. P. 2006. Hip resurfacing arthroplasty. The Journal of the American Academy of Orthopaedic Surgeons. 14(8), p. 454–463. Moretti, B., Pesce, V., Maccagnano, G., Vicenti, G., Lovreglio, P., Soleo, L. and Apostoli, P. 2012. Peripheral neuropathy after hip replacement failure: is vanadium the culprit? Lancet. 379(9826). p. 1676. Morsi, E., Habib, M. E., Elseedy, A. and Eid, T. 2016. Revision of failed hip hemiarthroplasty: Classification, management, and follow-up. Journal Of Orthopaedics. 13(2), p. 63–68. Musib, M. and Saha, S. 2010. Effect of wear-debris particles on RAW 264.7 cells. Proceedings Of The 2010 IEEE 36th Annual Northeast Bioengineering Conference, 26-28 March 2010, New York, USA. New York: IEEE, p. 32 - 33. Narayan, V. S., Ernsberger, C. and King, R. 2009. Pin-on-Disk wear studies of antioxidant-stabilized UHMWPE materials. [Poster]. 55th Annual Meeting of the Orthopaedic Research Society, 22-25th Feb, Las Vegas. National Joint Registry. 2016. NJR reports 2016. [online]. [Accessed: 31 August 2014]. Available from: http://www.njrreports.org.uk/hips-primary-procedures-patient-characteristics/H05v1NJR?reportid=351A3B2E-F983-4D53-BC1E-D9A90DC93AAA&defaults=DC__Reporting_Period__Date_Range=%22MAX%22,J__Filter__Calendar_Year=%22MAX%22,H__Filter__Joint=%22Hip%22. National Joint Registry. 2017. 2017 14th Annual Report - National Joint Registry For England, Wales, Northern Ireland And The Isle Of Man. [online]. [Accessed: 31 August 2014]. Available from: http://www.njrreports.org.uk/Portals/0/PDFdownloads/NJR 14th Annual Report 2017.pdf. Navarro-Zarza, J. E., Villaseñor-Oviesb, P., Vargas, A., Canoso, J. J., Chiapas-Gasca, K., Hernández-Díaz, C., Saavedra, M. A. and Kalish, R. A. 2012. Clinical Anatomy of the Pelvis and Hip. Reumatologia Clinica. 8(SUPPL.2), p. 33–38. Nich, C., Goodman, S. B. and Hospital, T. 2014 The role of macrophages in the biological reaction to wear debris from joint replacements. Journal Of Long Term Effects Of Medical Implants. 24(4), p. 259–265. Niche, C., Sariali, el-H., Hannouche, D., Nizard, R., Witvoet, J., Sedel, L. and Bizot, P. 2003. Long-term results of alumina-on-alumina hip arthroplasty for osteonecrosis. Clinical Orthopaedics And Related Research. 417, p. 102–111. Nizard, R., Sedel, L., Christel, P. Meunier, A., Soudry, M. and Witviet, J. 1992. Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clinical Orthopaedics. Sept(282), p. 53 – 63. Noordin, S., Umer, M., Hafeez, K. and Nawaz, H. 2010. Developmental dysplasia of the hip. Orthopedic Reviews. 2(2), p. 19. Oral, E., Greenbaum. E. S., Malhi, A. S., Harris, W. H. and Muratoglu, O. K. 2005. Characterization of irradiated blends of α-tocopherol and UHMWPE. Biomaterials. 26(33), p. 6657–6663. Oral, E., Christensen, S. D., Malhi, A. S., Wannomae, K. K. and Muratoglu, O. K. 2006. Wear Resistance and Mechanical Properties of Highly Cross-linked, Ultrahigh-Molecular Weight Polyethylene Doped With Vitamin E. Journal Of Arthroplasty. 21(4), p. 580–591. Oral, E., Wannomae, K. K., Rowell, S. L. and Muratoglu, O. K. 2007. Diffusion of vitamin E in ultra-high molecular weight polyethylene. Biomaterials. 28(35), p. 5225–5237. Oral, E., Malhi, A. S., Wannomae, K. K. and Muratoglu, O. K. 2008. Highly Crosslinked UHMWPE with Improved Fatigue Resistance for Total Joint Arthroplasty. Journal Of Arthroplasty. 23(7), p. 1037–1044. Oral, E., Malhi, A. S. and Muratoglu, O. K. 2006. Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE. Biomaterials. 27(6), p. 917–925. Oral, E and Muratoglu, O. 2009. Chapter 18: Highly cross-linked UHMWPE doped with vitamin E. Kurtz, S. Ed. UHMWPE Biomaterials Handbook. 2nd Edition. San Diego: Elsevier academic press, p. 307 - 325. Pandit, H., Glyn-Jones, S., McLardy-Smith, P., Gundle, R., Whitwell, D., Gibbons, C.L.M., Ostlere, S., Athanasou, N, Gill, H.S. and Murray, D. W. 2008. Pseudotumours associated with metal-on-metal hip resurfacings. Journal Of Bone And Joint Surgery: British Volume. 90(7), p. 920–3. Pandit, H., Vlychou, M., Whitwell, D., Crook, D., Luqmani, R., Ostlere, S., Murray, D. W. and Athanasou, N. A. 2008. Necrotic granulomatous pseudotumours in bilateral resurfacing hip arthroplasties: evidence for a type IV immune response. Virchows Archiv. 453(5), p. 529 – 534. Peng, Z.B., Hu, B., Su, Q.D. and Qu, J. Z. 2003. Study on mechanism of rare earth PVC stabilizer. Journal Of Rare Earths. 21(3), p. 328–330. Pennekamp, P. H., Caicedo, M., Catelas, I., Kunze, J., Laurent, M. P., Hallab, N. J., and WImmer, M. A. 2009. Lanthanides induce Diverse Cell Responses in Murine Macrophages. [Poster]. 55th Annual Meeting of the Orthopaedic Research Society, 22-25th Feb, Las Vegas Peterson, E. D., Nemanich, J. P., Altenburg, A. and Cabenela, M. E. 2009. Hip arthroplasty after previous arthrodesis. Clinical Orthopaedics And Related Research, 467(11), p. 2880–2885. Petis, S., Howard, J. L., Lanting, B. L. and Vasarhelyi, E. M. 2015. Surgical approach in primary total hip arthroplasty: Anatomy, technique and clinical outcomes. Canadian Journal Of Surgery. 58(2), p. 128–139. Popoola, O.O., Yao, J.A.Q., Johnson, T.S. and Blanchard, C. R. 2010. Wear, Delamination, and Fatigue Resistance of Melt-Annealed Highly Cross linked UHMWPE Cruciate-Retaining Knee Inserts under Activities of Daily Living. Journal Of Orthopaedic Research. 28(9), p. 1120–1126. Premnath, V., Harris, W.H., Jasty, M. and Merrill, E. W. 1996. Gamma sterilization of UHMWPE articular implants: An analysis of the oxidation problem. Biomaterials. 17(18), p. 1741–1753. Proff, P. and Römer, P. 2009. The molecular mechanism behind bone remodelling: A review. Clinical Oral Investigations. 13(4), p. 355–362. Puertolas, J.A. and Kurtz, S. M. 2016. UHMWPE matrix composites. In: Kurtz, S. ed. Ultrahigh Molecular Weight Polyethylene In Total Joint Replacements And Medical Devicse. London: Elsevier, p. 369–397. Rader, C. P., Sterner, T., Jakob, F., Schütze, N and Eulert, J. 1999. Cytokine response of human macrophage-like cells after contact with polyethylene and pure titanium particles. Journal Of Arthroplasty. 14(7), p. 840–848. Raisz, L. G. 1988. Local and systematic factors in the pathogenesis of osteoporosis. The New England Journal Of Medicine. 298(6), p. 337–339. Raisz, L. G. 2005. Pathogenesis of osteoporosis : concepts , conflicts , and prospects. Journal Of Clinical Investigation. 115(12), p. 3318–3325. Richards, L., Brown, C., Stone, M. H., Fisher, J., Ingham, E. and Tipper, J. L. 2008. Identification of nanometre-sized ultra-high molecular weight polyethylene wear particles in samples retrieved in vivo. Journal Of Bone And Joint Surgery: British Volume. 90(issue), p. 1106–1113. Richards, L. (2008) The biological activity of nanometre sized polymer particles. Ph.D. thesis, University of Leeds. Roodman, G. D. 2012. Vitamin E: Good for the heart, bad for the bones? Nature Medicine. 18(4), p. 491–492. Scholes, S. C. and Unsworth, A. 2006. The effects of proteins on the friction and lubrication of artificial joints. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 220(6), p. 687–693. Schubert, D., Dargusch, R., Raitano, J. and Chan, S. W. 2006. Cerium and yttrium oxide nanoparticles are neuroprotective. Biochemical And Biophysical Research Communications. 342(1), p. 86–91. Shishido, T., Clarke, I. C., Weber, F., Shoji, H. and Imakiire, A. 2002. Analysis of retrieved THR cups of highly cross-linked UHMWPE from South Africa. [Poster]. 48th Annual Meeting of the Orthopaedic Research Society, Feb, Dallas, Texas. Silverman, E. J., Ashley, B. and Sheth, N. P. 2016. Metal-on-metal total hip arthroplasty: is there still a role in 2016? Current Reviews In Musculoskeletal Medicine. 9(1), p. 93–96. Singh, U., Devaraj, S. and Jialal, I. 2005. Vitamin E, oxidative stress, and inflammation. Annual Review Of Nutrition. p. 151–174. Siskey, R., Smelt, H., Boon-Ceelan, K. and Persson, M. 2016. UHMWPE homocomposites and fibers. Ultrahigh Molecular Weight Polyethylene In Total Joint Replacements And Medical Device. 225(1), p. 398 – 411. Smith, J. T. (2016) A 3d culture model to investigate cellular responses to mechanical loading in spinal cord injury. Ph.D. thesis, University of Leeds. Smolen, J., Aletaha, D. and McInnes, I. B. 2016. Rheumatoid arthritis. Lancet. 388(10055), p. 2023–2038. Sokol, R. J. 1993. Vitamin E deficiency and neurological disorders. In: Packer, L. and Fuchs, J. eds. Oxidants, Antioxidants And Free Radicals. New York: Marcel Dekker. Suñer, S., Gowland, N., Craven, R., Joffe, R., Emami, N. and Tipper, J. L. 2018. Ultrahigh molecular weight polyethylene/graphene oxide nanocomposites: Wear characterization and biological response to wear particles. Journal Of Biomedical Materials Research - Part B Applied Biomaterials. 106(1), p. 183–190. Sutula, L.C., Collier, J.P., Saum, K.A., Currier, B.H., Currier, J.H., Sanford, W.M., Mayor, M. B., Wooding, R. E., Sperling, D. K. and Williams, I. R. 1995. Impact of gamma-sterilization on clinical-performance of polyethylene in the hip. Clinical Orthopaedics And Related Research. 319(issue), p. 28–40. Teitelbaum, S. L. 2006. Osteoclasts and integrins. in Zaidi, M. (ed.) Skeletal Development And Remodeling In Health, Disease, And Aging. Oxford: Blackwell Publishing, pp. 95–99. Teng, G. G., Curtis, J. R. and Saag, K. G. 2008. Mortality and osteoporotic fractures: Is the link causal, and is it modifiable?. Clinical And Experimental Rheumatology. 26(5 SUPPL. 51), p. 125 - 137. Teramura, S., Sakoda, H., Terao, T., Endo, M. M., Fujiwara, K. and Tomita, N. 2009. Reduction of wear volume from accelerated aged UHMWPE knee components by the addition of vitamin E. Journal Of Biomechanical Science And Engineering. 4(4), p. 589–596. Tipper, J., Ingham, E., Jin, Z., and Fisher, J. 2005. The science of metal-on-metal articulation. Current Orthopaedics. 19(4), p. 280 – 287. Tipper, J.L., Galvin, A.L., Williams, S., McEwen, H.M.J., Stone, M.H., Ingham, E., and Fisher, J. 2006. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators. Journal Of Biomedical Materials Research Part A. 78(3), p. 473–480. Tipper, J. L., Firkins, P. J., Ingham, E., Fisher, J., Stone, M. H. and Farrar, R. 2000. Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses. Journal Of Materials Science: Materials In Medicine. 11(2), p. 117–124. Tonino, A. J., Thèrin, M. and Doyle, C. 1999. Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem. The Journal Of Bone And Joint Surgery: British volume. 81(1), p. 148–54. Traina, F., De Fine, M., and Affatato, S. 2012. Anatomy of the hip and suitable prostheses. Wear Of Orthopaedic Implants And Artificial Joints. 2013, p.93-114. Traina, F. De Fine, M., Di Martino, A. and Faldini, C. 2013. Fracture of ceramic bearing surfaces following total hip replacement: A systematic review. BioMed Research International. 2013, p. 157247. Tubby, A. H. 1908. A clinical lecture on coxa valga. British Medical Journal. 2(2482), p. 185. Vaidya, C., Alvarez, E., Vinciguerra, J., Bruce, D. A. and Desjardins, J. D. 2011. Reduction of total knee replacement wear with vitamin e blended highly cross-linked ultra-high molecular weight polyethylene. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 225(1), p. 1–7. Vermes, C., Chandrasekaran, R., Jacobs, J. J., Galante, J. O., Roebuck, K. A., and Glant, T. T. 2001. The effects of particulate wear debris, cytokines, and growthfactors on the functions of MG-63 osteoblasts. The Journal Of Bone And Joint Surgery: American Volume. 83A(2), p. 201–211. Vignery, A. 2005. Macrophage fusion: are somatic and cancer cells possible partners? Medicine Science. 21(12), p. 1070–1075. Wang, A., Zeng, H., Yau, S.S., Essner, A., Manely, M. and Dumbleton, J. 2006. Wear, oxidation and mechanical properties of a sequentially irradiated and annealed UHMWPE in total joint replacement. Journal Of Physics D-Applied Physics. 39(15), p. 3213–3219. Wannomae, K. K., Christensen, S. D., Freiberg, A. A., Bhattacharyya, S., Harris, W. H. and Muratoglu, O. K. 2006. The effect of real-time aging on the oxidation and wear of highly cross-linked UHMWPE acetabular liners. Biomaterials. 27(9), p. 1980–1987. Wei, S., Kitaura, H., Zhou, P., Ross, F.P. and Teitelbaum, S. L. 2005. IL-1 mediates TNF-induced osteoclastogenesis. Journal Of Clinical Investigation. 115(2), p. 282–290. Weir, E.C., Lowik, C., Paliwal, I. and Insogna, K. L. 1996. Colony stimulating factor-1 plays a role in osteoclast formation and function in bone resorption induced by parathyroid hormone and parathyroid hormone-related protein. Journal Of Bone And Mineral Research. 11(10), p. 1474–1481. Williams, D. F. 1999. The Williams Dictionary Of Biomaterials. Liverpool, UK.: Liverpool University Press. Willmann, G. 1998. Ceramics for total hip replacement--what a surgeon should know. Orthopedics. 21(2), p. 173–177. Wolf, C., Lederer, K. and Muller, U. 2002. Tests of biocompatibility of alpha-tocopherol with respect to the use as a stabilizer in ultrahigh molecular weight polyethylene for articulating surfces in joint endoprostheses. Journal Of Materials Science: Materials In Medicine. 13(7), p. 701–705. Wolf, C., Lederer, K., Pfragner, R., Schauenstein, K., Ingolic, E. and Siegl, V. 2007. Biocompatibility of ultra-high molecular weight polyethylene (UHMW-PE) stabilized with α-tocopherol used for joint endoprostheses assessed in vitro. Journal Of Materials Science: Materials In Medicine. 18(6), p. 1247–1252. Wolfarth, D. L., Han, D. L., Bushar, G. and Parks, N. L. 1997. Separation and characterization of polyethylene wear debris from synovial fluid and tissue samples of revised knee replacements. Journal Of Biomedical Materials Research. 34(1), p. 57–61. Wu, J., Peng, Z. and Tipper, J. 2013. Mechanical properties and three-dimensional topological characterisation of micron, submicron and nanoparticles from artificial joints. Tribology Letters. 52(3), p. 449–460. Yavropoulou, M. P. and Yovos, J. G. 2008. Osteoclastogenesis--current knowledge and future perspectives. Journal Of Musculoskeletal & Neuronal Interactions. 8(June), p. 204–16. Zhang, W., Ouyang, H., Dass, C. R. and Xu, J. 2016. Current research on pharmacologic and regenerative therapies for osteoarthritis. Bone Research. 4(October), p. 15040 - 15054. Zheng, Y.Y., Cai, W.L., Fu, M.L., Wang, C.Y. and Zhang, X. 2005. Rare earth stearates as thermal stabilizers for rigid poly( vinyl chloride). Journal Of Rare Earths. 23(2), p. 172–177."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.778630"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/24128/1/LYW%20final%20thesis%20240519.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Osteolysis, and subsequent aseptic loosening, is the leading cause of revision in total hip replacements. The biological response to ultra-high molecular weight polyethylene (UHMWPE) wear debris is known to trigger the release of several inflammatory mediators such as tumour necrosis factor-alpha (TNF-α), interleukin-1β (IL-1β), interleukin-6 (IL-6), interleukin-8 (IL-8), leukotriene B4 (LTB4) and prostaglandin E2 (PGE2); all of which are involved in the signalling cascade that triggers the differentiation of osteoclasts and begins osteolysis. UHMWPE has undergone modifications such as cross-linking (to reduce the volume of wear debris produced) and antioxidant doping (to neutralise free radicals produced by irradiative crosslinking and prevent oxidative embrittlement). Previous studies at the University of Leeds, using peripheral blood mononuclear cells (PBMNCs) cultured on wear particle containing agarose gel, have shown that antioxidant doped, highly cross-linked UHMWPE may reduce the production of osteolytic cytokines in comparison to highly cross-linked UHMWPE. This model has limitations; namely donor heterogeneity associated with the use of PBMNC’s in addition to the use of a 2D model for what is a 3D in vivo environment. The aims of this study were to develop a novel 3D model in which mononuclear phagocytes and wear particles were encapsulated within a gel and to use the model to compare the cellular production of osteolytic cytokines when treated with highly cross-linked UHMWPE and antioxidant doped, highly cross-linked UHMWPE wear debris. Three different cell types (PBMNC’s, U937 human histiocytes and RAW 264.7 murine macrophages) and two gel types (agarose and type I rat tail collagen) were investigated during the development of the 3D model. It was found that the use of RAW 264.7 murine macrophages and UHMWPE wear debris simultaneously trapped inside a collagen gel matrix was the most promising model. A large volume of sterile highly cross-linked UHMWPE wear debris (with and without antioxidant doping) was generated using pin-on-plate (POP) multidirectional wear simulator rigs for use in the 3D model. RAW 264.7 murine macrophages were cultured with both unfractionated UHMWPE wear debris, or a filtered, critical size range (0.1 – 1 μm) of UHMWPE wear debris. RAW 264.7 murine macrophages cultured in the 3D model with unfractionated UHMWPE wear debris showed no difference in oxidative stress levels or TNF-α, IL-1β, IL-6, KC (CXCL-1 – a murine homologue of IL-8), LTB4 and PGE2 levels produced in response to highly cross-linked UHMWPE wear debris with and without antioxidant doping compared to the cells only controls. Similarly, RAW 264.7 murine macrophages cultured in the 3D model with a critical size range (0.1 – 1 μm) of UHMWPE wear debris showed no difference in oxidative stress levels or TNF-α, IL-1β, IL-6, KC, LTB4 and PGE2 levels when treated with highly cross-linked UHMWPE wear debris with and without antioxidant doping compared to the cells only controls. RAW 264.7 murine macrophages were also stimulated with LPS in the 3D model and then treated with Protein Kinase C (PKC) inhibitors (Calphostin C and Bisindolylmaleimide I), 5-lipoxygenase (5-LO) inhibitors (MK 886 and REV 5901), Cycloxygenase (COX) inhibitor (Indomethacin) and antioxidants (α –tocopherol and pentaerythritol tetrakis(3,5-di-tert-butyl-4-hydroxyhydrocinnamate)) after three hours. RAW 264.7 murine macrophages treated with both PKC inhibitors and both antioxidants showed reduced levels of TNF-α and IL-6 when compared to the LPS only control. All inhibitors and antioxidants reduced the production of IL-1β when compared to the LPS only control. Cells treated with Calphostin C exhibited a reduced production of LTB4 and PGE2 when compared to the LPS only control. Microscopy images of RAW 264.7 murine macrophages cultured in the novel 3D model incubated with 0.1 – 1 μm antioxidant doped, highly cross-linked UHMWPE wear debris and FluoSpheres® showed that the RAW 264.7 murine macrophages sequestered the UHMWPE wear debris in the perinuclear lysosomes, indicating attempted phagocytosis, which is consistent with the previous studies. Overall, the RAW 264.7 murine macrophages cultured in the novel 3D model largely failed to produce inflammatory and osteolytic cytokines, chemokines and mediators in response to the UHMWPE wear debris generated in this study. However the novel model showed some promise by demonstrating the link between vitamin E and PKC in reducing the production of inflammatory and osteolytic mediators as shown in previous studies. The novel culture model requires further work to produce a more accurate in vitro representation of the 3D periprosthetic environment for use in future studies."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of a novel 3D in vitro model to measure cellular response to antioxidant doped highly cross-linked ultra high molecular weight polyethylene wear debris"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tipper, Joanne","Williams, Sophie","Hewitt, Eric"],"dc:contributor.sponsor":["EPSRC"],"dc:creator":["Yarrow-Wright, Lauren Elizabeth"],"dc:date":["2018-09-30"],"dc:date.issued":["2018-09"],"dc:description.abstract":["Osteolysis, and subsequent aseptic loosening, is the leading cause of revision in total hip replacements. The biological response to ultra-high molecular weight polyethylene (UHMWPE) wear debris is known to trigger the release of several inflammatory mediators such as tumour necrosis factor-alpha (TNF-α), interleukin-1β (IL-1β), interleukin-6 (IL-6), interleukin-8 (IL-8), leukotriene B4 (LTB4) and prostaglandin E2 (PGE2); all of which are involved in the signalling cascade that triggers the differentiation of osteoclasts and begins osteolysis. UHMWPE has undergone modifications such as cross-linking (to reduce the volume of wear debris produced) and antioxidant doping (to neutralise free radicals produced by irradiative crosslinking and prevent oxidative embrittlement). Previous studies at the University of Leeds, using peripheral blood mononuclear cells (PBMNCs) cultured on wear particle containing agarose gel, have shown that antioxidant doped, highly cross-linked UHMWPE may reduce the production of osteolytic cytokines in comparison to highly cross-linked UHMWPE. This model has limitations; namely donor heterogeneity associated with the use of PBMNC’s in addition to the use of a 2D model for what is a 3D in vivo environment. The aims of this study were to develop a novel 3D model in which mononuclear phagocytes and wear particles were encapsulated within a gel and to use the model to compare the cellular production of osteolytic cytokines when treated with highly cross-linked UHMWPE and antioxidant doped, highly cross-linked UHMWPE wear debris. Three different cell types (PBMNC’s, U937 human histiocytes and RAW 264.7 murine macrophages) and two gel types (agarose and type I rat tail collagen) were investigated during the development of the 3D model. It was found that the use of RAW 264.7 murine macrophages and UHMWPE wear debris simultaneously trapped inside a collagen gel matrix was the most promising model. A large volume of sterile highly cross-linked UHMWPE wear debris (with and without antioxidant doping) was generated using pin-on-plate (POP) multidirectional wear simulator rigs for use in the 3D model. RAW 264.7 murine macrophages were cultured with both unfractionated UHMWPE wear debris, or a filtered, critical size range (0.1 – 1 μm) of UHMWPE wear debris. RAW 264.7 murine macrophages cultured in the 3D model with unfractionated UHMWPE wear debris showed no difference in oxidative stress levels or TNF-α, IL-1β, IL-6, KC (CXCL-1 – a murine homologue of IL-8), LTB4 and PGE2 levels produced in response to highly cross-linked UHMWPE wear debris with and without antioxidant doping compared to the cells only controls. Similarly, RAW 264.7 murine macrophages cultured in the 3D model with a critical size range (0.1 – 1 μm) of UHMWPE wear debris showed no difference in oxidative stress levels or TNF-α, IL-1β, IL-6, KC, LTB4 and PGE2 levels when treated with highly cross-linked UHMWPE wear debris with and without antioxidant doping compared to the cells only controls. RAW 264.7 murine macrophages were also stimulated with LPS in the 3D model and then treated with Protein Kinase C (PKC) inhibitors (Calphostin C and Bisindolylmaleimide I), 5-lipoxygenase (5-LO) inhibitors (MK 886 and REV 5901), Cycloxygenase (COX) inhibitor (Indomethacin) and antioxidants (α –tocopherol and pentaerythritol tetrakis(3,5-di-tert-butyl-4-hydroxyhydrocinnamate)) after three hours. RAW 264.7 murine macrophages treated with both PKC inhibitors and both antioxidants showed reduced levels of TNF-α and IL-6 when compared to the LPS only control. All inhibitors and antioxidants reduced the production of IL-1β when compared to the LPS only control. Cells treated with Calphostin C exhibited a reduced production of LTB4 and PGE2 when compared to the LPS only control. Microscopy images of RAW 264.7 murine macrophages cultured in the novel 3D model incubated with 0.1 – 1 μm antioxidant doped, highly cross-linked UHMWPE wear debris and FluoSpheres® showed that the RAW 264.7 murine macrophages sequestered the UHMWPE wear debris in the perinuclear lysosomes, indicating attempted phagocytosis, which is consistent with the previous studies. Overall, the RAW 264.7 murine macrophages cultured in the novel 3D model largely failed to produce inflammatory and osteolytic cytokines, chemokines and mediators in response to the UHMWPE wear debris generated in this study. However the novel model showed some promise by demonstrating the link between vitamin E and PKC in reducing the production of inflammatory and osteolytic mediators as shown in previous studies. The novel culture model requires further work to produce a more accurate in vitro representation of the 3D periprosthetic environment for use in future studies."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.778630"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/24128/1/LYW%20final%20thesis%20240519.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/24128/"],"dc:relation.references":["List of References Abildtrup, M., Kingsley, G. H. and Scott, D. L. 2015. Calprotectin as a biomarker for rheumatoid arthritis: a systematic review. The Journal Of Rheumatology. 42(5), p. 760–770. Affatato, S., Spinello, M., Zavalloni, M., Mazzega-Fabbro, C. and Viceconti, M. 2008). Tribology and total hip joint replacement: Current concepts in mechanical simulation. Medical Engineering And Physics. 30(10), p. 1305–1317. Anderson, D. E. and Johnstone, B. 2017. Dynamic Mechanical Compression of Chondrocytes for Tissue Engineering: A Critical Review. Frontiers In Bioengineering And Biotechnology. 5(December), p. 1–20. Anderson, J. M., Rodriguez, A. and Chang, D. T. 2008. Foreign body reaction to biomaterials. Seminars In Immunology. 20(2), pp. 86–100. Arden, N. and Nevitt, M. C. 2006. Osteoarthritis: Epidemiology. Best Practice And Research: Clinical Rheumatology. 20(1), p. 3–25. Arend, W. P. 1995. Inhibiting the effects of cytokines in human diseases. Advances In Internal Medicine. 40, p. 365 – 394. De Bandt, M., Grossin, M., Driss, F., Pincemail, J., Bain-Chevaye, C. and Pasquier, C. 2002. Vitamin E uncouples joint destruction and clinical inflammation in a transgenic mouse model of rheumatoid arthritis. Arthritis And Rheumatism. 46(2), p. 522–532. Barbour, P. S. M. 1999. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 213(6), p. 455–467. Baxter, R. M. Steinbeck, M. J., Tipper, J. L., Parvizi, J., Marcolongo, M. and Kurtz, S. M. 2009. Comparison of periprosthetic tissue digestion methods for ultra-high molecular weight polyethylene wear debris extraction. Journal Of Biomedical Materials Research - Part B Applied Biomaterials. 91(1), p. 409–418. Bellare, A., Schnablegger, H., and Cohen, R. E. 1995. A small-angle x-ray scattering study of high-density polyethylene and ultra-high molecular weight polyethylene. Macromolecules, 17, p. 2325–2333. Bergschmidt, P., Bader, R., and Mittelmeier, W. 2012. Metal hypersensitivity in total knee arthroplasty: Revision surgery using a ceramic femoral component – a case report. The Knee. 19, p. 144 – 147. Berlin, J. A., Braithwaite, G. J. C., Knight, J., Pletcher, D. and Rufner, A. 2011. Oxidative Stability of Highly Crosslinked Vitamin E UHMWPE Blends in Extreme and Physiological Accelerated Aging Conditions. [Poster]. ORS 2011 Annual Meeting, 13 - 16th Jan, California. Besong , A.A., Hailey, J.L., Ingham, E., Stone, M., Wroblewski, B.M. and Fisher, J. 1997. A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE. Biomedical Materials And Engineering. 7(1), p. 59–65. Bichara, D. A., Malchau, E., Sillesen, N. H., Cakmak, S., Nielsen, G. P. and Muratoglu, O. K. 2014. Vitamin E-diffused highly cross-linked UHMWPE particles induce less osteolysis compared to highly cross-linked virgin UHMWPE particles in vivo. Journal Of Arthroplasty. 29(9 SUPPL.), p. 232–237. Birnkraut, H. W. 1991. Synthesis of UHMWPE. In Willert, H.G., Buchhorn, G.H., and Eyerer, P. eds. Ultra-high Molecular Weight Polyethylene As A Biomaterial In Orthopedic Surgery. Lewiston, New York: Hogrefe & Huber. Bladen, C. L., Teramura, S., Russell, S. L., Fujiwara, K., FIsher, J., Ingham, E., Tomita, N. and Tipper, J. L. 2013a. Analysis of wear, wear particles, and reduced inflammatory potential of vitamin e ultrahigh-molecular-weight polyethylene for use in total joint replacement. Journal Of Biomedical Materials Research - Part B Applied Biomaterials. 101 B(3), p. 458–466. Bladen, C. L., Tzu-Yin, L., FIshe, J. and Tipper, J. L. 2013b. In vitro analysis of the cytotoxic and anti-inflammatory effects of antioxidant compounds used as additives in ultra high-molecular weight polyethylene in total joint replacement components. Journal Of Biomedical Materials Research - Part B Applied Biomaterials. 101 B(3), p. 407–413. Bracco, P., Bellare, A., Bistolfi, A. and Affatato, S. 2017. Ultra-high molecular weight polyethylene: Influence of the chemical, physical and mechanical properties on the wear behavior. A review. Materials. 10(7), p. 791 - 813. Bracco, P. and Oral, E. 2011. Vitamin E-stabilized UHMWPE for total joint implants: A review. Clinical Orthopaedics And Related Research. 469(8), p. 2286–2293. Brach Del Prever, E.M., Bistolfi, A., Bracco, P. and Costa, L. 2009. UHMWPE for arthroplasty: past or future?. Journal Of Orthopaedics And Traumatology : Official Journal Of The Italian Society Of Orthopaedics And Traumatology. 10(1), p. 1–8. Brigelius-Flohé, R. and Traber, M. G. 1999. Vitamin E: function and metabolism. The FASEB Journal. 13(10), p. 1145–1155. Brooks, R. A., Wimhurst, J. A. and Rushton, N. 2002. Endotoxin contamination of particles produces misleading inflammatory cytokine responses from macrophages in vitro. The Journal Of Bone And Joint Surgery. British Volume. 84(2), p. 295–299. Brown, C., Fisher, J., and Ingham, E. 2006. Biological effects of clinically relevant wear particles from metal-on-metal hip prostheses. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 220(2), p. 355 – 369. Burton, G. W. 1990. Vitamin E: Antioxidant Activity, Biokinetics, And Bioavailability. Annual Review Of Nutrition. 10, p. 357 - 382. Callaghan, J. J., Templeton, J. E., Liu, S. S., Pedersen, D. R., Goetz, D. D., Sullivan, P. M., and Johnston, R. C. 2004. Results Of Charnley Total Hip Arthroplasty At A Minimum Of Thirty Years. The Journal Of Bone And Joint Surgery. American Volume. 86–A(4), p. 690–695. Campbell, P., Ma, S., Schmalzreid, T. and Amstutz, H. C. 1996. Tissue digestion for wear debris particle isolation. Journal Of Biomedical Materials Research. 29(10), p. 1393–1397. Catelas, I., Petit, A., Marchand, R., Zukor, D., Yahia, L., and Huk, O. 1999. Cytotoxicity and macrophage cytokine induced by ceramic and polyethylene particles in vitro. The Journal Of Bone And Joint Surgery. 81B(issue), p. 516 – 521. Charnley, J. 1961. Arthroplasty of hip – a new operation. Lancet, 1(7187), p. 1129–1132. Chiu, Y. G. and Ritchlin, C. T. 2017. Denosumab: targeting the RANKL pathway to treat rheumatoid arthritis. Expert Opinion On Biological Therapy. 17(1), p. 119–128. Cho, D. R., Shanbhag, A. S., Hong, C. Y., Baran, G. R. and Goldring, S. R. 2002. The role of adsorbed endotoxin in particle-induced stimulation of cytokine release. Journal Of Orthopaedic Research. 20(4), p. 704–713. Chumakov, M. 2009. Nitroxides as free radical scavengers in UHMWPE. [Poster]. 55th Annual Meeting of the Orthopaedic Research Society, 22-25th Feb, Las Vegas. Collier, J.P., Sperling, D.K., Currier, J.H., Sutula, L.C., Saum, K.A. and Mayor, M. B. 1996. Impact of gamma sterilization on clinical performance of polyethylene in the knee. The Journal Of Arthroplasty. 11(4), p. 377–389. Conner, E.M. and Grisham, M. B. 1996. Inflammation, free radicals, and antioxidants. Nutrition. 12(4), p. 247–277. Cooper, J. R., Dowson, D. and Fisher, J. 1993. Macroscopic and microscopic wear mechanisms molecular weight polyethylene in ultra-high. Wear. 162-164 (A), p. 378–384. Costa, A.G., Cusano, N.E., Silva, B.C., Cremers, S. and Bilezikian, J. P. 2011. Cathepsin K: its skeletal actions and role as a therapeutic target in osteoporosis. Nature Reviews Rheumatology. 7(8), p. 447–456. Costa, L. and Bracco, P. 2009. Mechanisms of Crosslinking, Oxidative Degradation and Stabilization of UHMWPE. In Kurtz, S. M. ed. UHMWPE Biomaterials Handbook. San Diego: Elsevier Academic Press Inc, pp. 309–323. Craig, R. Vlycou, M., McCArthy, C. L., Gibbons, C. L. M. H. and Athanasou, N. A. 2017. Metal wear-induced pseudotumour following an endoprosthetic knee replacement for Ewing sarcoma. Skeletal Radiology. 46(7), p. 967–974. Cummings, S. R., Kelsey, J.L., Nevitt, M. and O’Dowd, K. J. 1985. Epidemiology of osteoporosis and osteoporotic fractures. Australian Prescriber. 20(SUPPL. 3), p. 13–17. Devaraj, S. and Jialal, I. 1999. Alpha-Tocopherol Decreases Interleukin-1β Release From Activated Human Monocytes by Inhibition of 5-Lipoxygenase’. Arteriosclerosis, Thrombosis And Vascular Biology. 19(4), p. 1125 - 1133. Devaraj, S., Li, D. and Jialal, I. 1996. The effects of alpha tocopherol supplementation on monocyte function: Decreased lipid oxidation, interleukin 1β secretion, and monocyte adhesion to endothelium. Journal Of Clinical Investigation. 98(3), p. 756–763. Devine, T.M. and Wulff, J. 1975. Cast vs. wrought cobalt-chromium surgical implant alloys. Journal Of Biomedical Materials Research. 9(2), p. 151–67. Dolezel, B. and Adamirova, L. 1982. Method of hygienically safe stabilization of polyolefines against thermoxidative and photoxidative degradation. Czechislovakian Socialist Republic Patent, 221:403. Dorlot, J-M., Christel, P. and Meunier, A. 1989. Wear analysis of retrieved alumina heads and sockets of hip prostheses. Journal Of Biomedical Materials Research. 23(A3 suppl), p. 299–310. Duff, G. W. 1993. Cytokines and anti-cytokines. British Journal Of Rheumatology. 32(1), p. 15–20. Dumbleton, J. H., Manley, M. T. and Edidin, A. A. 2002. A literature review of the association between wear rate andosteolysis in total hip arthroplasty. Journal Of Arthroplasty. 17(5), p. 649 - 661. Edidin, A.A. and Kurtz, S. M. 2000. The influence of mechanical behavior on the wear of four clinically relevant polymeric biomaterials in a hip simulator. Journal Of Arthroplasty. 15(3), p. 321–331. Endo, M. M., Barbour, P. S., Barton, D. C., Fisher, J., Tipper, J. L., Ingham, E. and Stone, M. H. 2001. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene. Biomedical Materials And Engineering. 11(1), p. 23–35. Endo, M., TIpper, J. L., Barton, D. C., Stone, M. H., Ingham, E. and Fisher, J. 2002. Comparison of wear, wear debris, and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 216 (2), p. 111 - 122. Feldman, L.A. and Hui, H. K. 1997. Compatibility of medical devices and materials with low-temperature hydrogen peroxide gas plasma. Medical Device And Diagnostic Industry. 19(12), p. 57–62. Franzen, H., Carlsson, Å., Johnsson, R., Rydholm, A., Önnerfält, R. 1994. Bony atrophy after mega total hip replacement for bone tumors: 11 cases followed for 3-15 years. Acta Orthopaedica. 65(5), p. 513–516. Fröhlich, S. M., Dorrer, V., Archodoulaki, V-M., Allmaier, G. and Marchetti-Deschmann, M. 2014. Synovial fluid protein adsorption on polymer-based artificial hip joint material investigated by MALDI-TOF mass spectrometry imaging. EuPA Open Proteomics. 4(2014), pp. 70–80. Fu, J., Shen, J., Gao, G., Xu, Y., Hou, R., Cong, Y. and Cheng, Y. 2013. Natural polyphenol-stabilised highly crosslinked UHMWPE with high mechanical properties and low wear for joint implants. Journal Of Materials Chemistry B. 1(37), p. 4727–4735. Gallardo, L. A., Knowlton, C. B., Kunze, J., Jacobs, J. J., Wimmer, M. A. and Laurent, M. P. 2011a. Effect of europium(II) stearate on the mechanical properties and the oxidation resistance of UHMWPE. Journal Of The Mechanical Behavior Of Biomedical Materials. 4(5), p. 821–826. Gallardo, L. A., Carpentieri, I., Laurent, M. P., Costa, L. and Wimmer, M. A. 2011b. Europium stearate additives delay oxidation of UHMWPE for orthopaedic applications: A pilot study. Clinical Orthopaedics And Related Research. 469(8), p. 2294–2301. Galvin, A., Kang, L., Tipper, J., Stone, M., Ingham, E., Jin, Z. and Fisher, J. 2006. Wear of crosslinked polyethylene under different tribological conditions. Journal of Materials Science: Materials In Medicine. 17(3), p. 235–243. Germain, M., Hatton, A., Williams, S., Matthews, J. B., Stone, M. H., Fisher, J. and Ingham, E. 2003. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials. 24(3), p. 469 – 479. Gijsman, P., Smelt, H.J. and Schumann, D. 2010. Hindered amine light stabilizers: An alternative for radiation cross-linked UHMWPE implants. Biomaterials. 31(26), p. 6685–6691. Goldring, M. B. and Goldring, S. R. 2007. Osteoarthritis. Journal Of Cellular Physiology. 213(3), p. 626–634. Goode, A. E., Perkins, J. M., Sandison, A., Karunakaran, C., Cheng, H., Wall, D., Skinner, J. A., Hart, A. J., Porter, A. E., McComb, D. W. and Ryan, M. P. 2012. Chemical speciation of nanoparticles surrounding metal-on-metal hips. Chemical Communications. 48(67), p. 8335–8337. Goodman, S. M. 2013. Rheumatoid Arthritis Preoperative Evaluation for Total Hip and Total Knee Replacement Surgery. Journal Of Clinical Rheumatology. 19(4), p. 187–92. Gowland, N. 2014. The Wear and Biological Activity of Antioxidant UHMWPE for use in Total Hip Replacements. Ph.D. thesis, University of Leeds. Granchi, D., Cenni, E., Giunti, A., and Baldini, N. 2012. Metal hypersensitivity testing in patients undergoing joint replacement: a systematic review. The Journal Of Bone And Joint Surgery. 94B(8), p. 1126–1134. Granchi, D., Cennis, E., Trisolino, G., Giunti, A., and Baldini, N. 2006. Sensitivity to implant materials in patients undergoing total hip replacement. Journal Of Biomedical Material Research B: Applied Biomaterials. 77(2), p. 257 – 264. Gray, H. 2019a. Gray’s Anatomy: Hip anatomy. [online]. [Accessed: 22 April 2019]. Available from: https://upload.wikimedia.org/wikipedia/commons/f/f1/Gray339.png Gray, H. 2019b. Gray's Anatomy: Hip anatomy. [online]. [Accessed: 22 April 2019]. Available from: https://upload.wikimedia.org/wikipedia/commons/3/33/Gray340.png Gray, H. 2014a. Gray’s Anatomy. Pelvis anatomy. [online]. [Accessed: 31 August 2014]. Available from: http://upload.wikimedia.org/wikipedia/commons/9/98/Gray241.png Gray, H. 2014b. Grays Anatomy. Femoral head anatomy., online]. [Accessed: 31 August 2014]. Available from: http://upload.wikimedia.org/wikipedia/commons/9/97/Gray243.png Green, J.M., Hallab, N.J., Senyurt, A., Liao, P., O’Keefe, R.J., Schwarz, E.M. and Xie, C. 2012. Effects of anti-oxidation treatments during the manufacturing of ultra high molecular weight polyethylene prosthetic components on their osteolytic and osteogenic properties as wear debris particles in a murine calvaria model. Current Rheumatology Reports. 26(1951), p. 61307. Green, T. R., Fisher, J., Stone, M. H., Wroblewski, B. M and Ingham, E. 1998. Polyethylene particles of a “critical size” are necessary for the induction of cytokines by macrophages in vitro. Biomaterials. 19(24), p. 2297–2302. Green, T. R., Fisher, J., Matthews, J. B., Stone, M. H. and Ingham, E. 2000. Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. Journal Of Biomedical Materials Research. 53(5), p. 490–497. Han, K.H., Ryu, J.W., Lim, K.E., Lee, S.H., Kim, Y., Hwang, C.S., Choi, J. Y. and Han, K. O. 2014. Vascular expression of the chemokine CX3CL1 promotes osteoclast recruitment and exacerbates bone resorption in an irradiated murine model. Bone. 61, p. 91–101. Hannouche, D., Hamadouche, M., Nizard, W., Bizot, P., Meunier, A. and Sedel, L. 2005. Ceramics in total hip replacement. Clinical Orthopaedics And Related Research. Jan(430), p. 62–71. He, S., Le, K-P., Blitz, J.W., Yau, S-S., Korduba, L.A. and Wang, A. 2009. Anthocyanin doped UHMWPE : oxidation, wear and mechanical properties. [Poster]. 55th Annual Meeting of the Orthopaedic Research Society, 22-25th Feb, Las Vegas. He, S., Yau, S-S., Wang, A. and Lawrynowicz, D. E. 2012. Polyethylene Cross-linked With An Anthocyanin. Patent. US8133436B2. Holliday, L.S., Bubb, M.R., Jiang, J., Hurst, I.R. and Zuo, J. 2005. Interactions between vacuolar H+-ATPases and microfilaments in osteoclasts. Journal Of Bioenergetics And Biomembranes. 37(6), p. 419–423. Howling, G. I., Barnett, P. I., Tipper, J. L., Stone, M. H., Fisher, J. and Ingham, E. 2001. Quantitative characterization of polyethylene debris isolated from periprosthetic tissue in early failure knee implants and early and late failure Charnley hip implants. Journal Of Biomedical Materials Research. 58(4), p. 415–420. Inada, M., Wang, Y., Byrne, M.H., Miyaura, C. and Krane, S. M. 2003. The collagenase, matrix metalloproteinase-13 (MMP-13), is required for osteoclast formation and function. Journal Of Bone And Mineral Research. 18, p. 195. Ingham, E. and Fisher, J. 2000. Biological Reaction to Wear Debris in Total Joint Replacement. Proceedings Of The Institution Of Mechanical Engineers. Part H. 73(2), p. 21–37. Ingham, E. and Fisher, J. 2005. The role of macrophages in osteolysis of total joint replacement. Biomaterials. 26(11), p. 1271–1286. Ingram, J. H., Stone, M. H., Fisher, J. and Ingham, E. 2004. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles. Biomaterials. 25(17), p. 3511–3522. Isaac, G. H., Dowson, D. and Wroblewski, B. M. 1996. An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups-wear, creep or degradation ? Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 210(3), p. 209–216. Jacobsen, S., Rømer, L., and Søballe, R. 2006. The other hip in unilateral hip dysplasia. Clinical Orthopaedics And Related Research. 446, p. 239 – 246. Jahan, M.S., Wang, C., Schwartz, G. and Davidson, J. A. 1991. Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation. Journal Of Biomedical Materials Research. 25(8), p. 1005–1017. James, S.P., Oldinski, R., Zhang, M. and Schwartz, H. 2016. UHMWPE-hyaluronan microcomposite biomaterials. In: Kurtz, S. Ultrahigh Molecular Weight Polyethylene In Total Joint Replacements And Medical Devices. San Diego: Elsevier academic press, p. 352 – 368. Janeway, C. A., Travers, P., Walport, M. and Schlomchik, M. J. 2001. Immunobiology. 5th Edition. New York: Garland Science. Jarrett, B. T., Cofske, J., Rosenberg, A. E., Oral, E., Muratoglu, O., and Malchau, H. 2010. In Vivo Biological Response to Vitamin E and Vitamin-E-Doped Polyethylene. The Journal Of Bone And Joint Surgery American Volume. 92A(16), p. 2672–2681. Jazrawi, L. M., Bogner, E., Della Valle, C. J., Chen, F. S., Pak, K. I., Stuchin, S. A., Frankel, V. H., and Di Cesare, P. E. 1999. Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants. A 12-year follow-up study. The Journal Of Arthroplasty. 12(7), p. 781 - 787. Kannu, P. and Howard, A. 2014. Perthes’ disease. British Medical Journal. 349, p.5584. Khan, H., Riva, F., Presacco, M., Meswania, J., Panagiotidou, A., Coathup, M., and Blunn, G. W. 2018. Development of the Lima ceramic hip resurfacing system: revision of hip resurfacing using a dual taper ceramic head and taper adaptor in an in vitro model. Orthopaedic Proceedings. 99B(4), p.61 Kim, M.S., Day, C.J. and Morrison, N. A. 2005. MCP-1 is induced by receptor activator of nuclear factor-kappa B ligand, promotes human osteoclast fusion, and rescues granulocyte macrophage colony-stimulating factor suppression of osteoclast formation. Journal Of Biological Chemistry. 280(16), p. 16163–16169. Kim, K., Lee, S-H., Kim, J. H., Choi, Y. and Kim, N. 2006. NFATc1 induces osteoclast fusion via up-regulation of osteoclast fusion and increased bone formation. Nature Medicine. 12, p. 1403–1409. Kim, Y., Sato, K., Asagiri, M., Morita, I., Soma, K. and Takayanagi, H. 2005. Contribution of nuclear factor of activated T cells c1 to the transcriptional control of immunoreceptor osteoclast-associated receptor but not triggering receptor expressed by myeloid cells-2 during osteoclastogenesis. Journal Of Biological Chemistry. 280(38), p. 32905–32913. King, R; Arscott, E and Narayan, V. 2010. Biocompatibility Study of Gamma-irradiated UHMWPE Stabilized with a Hindered-Phenol Antioxidant. [Poster]. 56th Annual Meeting of the Orthopaedic Research Society, 6th-9th Mar, New Orleans, Louisiana. Klaue, K., Durnin, C.W. and Ganz, R. 1991. The acetabular rim syndrome - a clinical presentation of dysplasia of the hip. Journal Of Bone And Joint Surgery - British Volume. 73(3), p. 423–429. Koureas, G., Wicart, P., and Serine, R. 2007. Etiology of developmental hip dysplasia or dislocation: review article. HIP International. 17(5), p. 1–7. Kurtz, S.M., Muratoglu, O.K., Evans, M. and Edidin, A. A. 1999. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials. 20(issue), p. 1659–1688. Kurtz, S. 2004a. Chapter 1: A primer on UHMWPE. Kurtz, S. Ed. The UHMWPE Handbook. San Diego: Elsevier academic press, p. 1 - 12. Kurtz, S. 2004b. Chapter 2: From ethylene gas to UHMWPE component: the process of producing orthopedic implants. Kurtz, S. Ed. The UHMWPE Handbook. San Diego: Elsevier academic press, p. 13 - 36. Kurtz, S. 2004c. Chapter 3: Packaging and sterilzation of UHMWPE. Kurtz, S. Ed. The UHMWPE Handbook. San Diego: Elsevier academic press, p. 37 - 51. Kyomoto, M., Moro, T. and Ishihara, K. 2016. Phospholipid polymer grafted highly cross-linked UHMWPE. In: Kurtz, S. ed. Ultrahigh molecular weight polyethylene in total joint replacements and medical device. 3rd Edition. San Diego: Elsevier academic Press, p. 352 – 368. Lancaster, J. G., Dowson, D., Isaac, G. H. and Fisher, J. 1997. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 211(1), p. 17–24. Laslo P, Spooner CJ, Warmflash A, Lancki DW, Lee HJ, Sciammas R, Gantner, B. N., Dinner, A. R. and Singh, H. 2006. Multilineage transcriptional priming and determination of alternate hematopoietic cell fates. Cell. 126(4), p. 755–766. Lee, D. M. and Weinblatt, M. E. 2001. Rheumatoid arthritis. Lancet. 358(9285), p. 903–911. Lee, H. 2016. Spinal Cord Cellular Response To Wear Debris From Metal-on-Metal Total Disc Replacements. Ph.D. thesis, University of Leeds. Liu, A. 2012. Determination of the biological response and cellular uptake mechanisms of nanometre-sized UHMWPE wear particles from total hip replacements. Ph.D. thesis, University of Leeds. Liu, A., Richards, L., Bladen, C. L., Ingham, E., Fisher, J. and Tipper, J. L. 2015. The biological response to nanometre-sized polymer particles. Acta Biomaterialia. 23, p. 38 - 51. Malik, J., Hrivik, A. and Tomova, E. 1992. Diffusion of hindered amine light stabilizers in low-density polyethylene and isotactic polypropylene. Polymer Degradation And Stability. 35(1), p. 61–66. Man, G. S. and Mologhianu, G. 2014. Osteoarthritis pathogenesis - a complex process that involves the entire joint. Journal Of Medicine And Life. 7(1), p. 37–41. Margevicius, K. J., Bauer, T. W., McMahon, J. T., Brown, S. A. and Merritt, K. 1994. Isolation and characterization of debris in membranes around total joint prostheses. Journal Of Bone And Joint Surgery - Series A. 76(11), p. 1664–1675. Martell, J., Berkson, E. and Jacobs, J. J. 2000. The performance of 2D vs. 3D computerized wear analysis in the Harris Galante acetabular component. Orthopaedic Transactions. 25(564), p. 88. Matsumoto, M., Kogawa, M., Wada, S., Takayanagi, H., Tsujimoto, M., Katayama, S., Hisatake, K. and Nogi, Y. 2004. Essential role of p38 mitogen-activated protein kinase in cathepsin K gene expression during osteoclastogenesis through association of NFATc1 and PU.1. Journal Of Biological Chemistry. 279(44), p. 45969–45979. Matsusaki, T., Kawanabe, K., Ise, K., Nakayama, T., Toguchida, J., and Nakamura, T. Gene Expression Profile of Macrophage-Like U937 Cells in Response to Polyethylene Particles. A Novel Cell-Particle Culture System. Journal Of Arthroplasty. 22(7), p. 960–965. Matthews, J. B., Green, T. R., Stone, M. H., Wroblewski, B. M., Fisher, J. and Ingham, E. 2000a. Comparison of the response of primary human peripheral blood mononuclear phagocytes from different donors to challenge with model polyethylene particles of known size and dose. Biomaterials. 21(20), p. 2033–2044. Matthews, J. B., Green, T. R., Stone, M. H.,Wroblewski, B. M., Fisher, J. and Ingham, E. 2000c. Comparison of the response of primary murine peritoneal macrophages and the U937 human histiocytic cell line to challenge with in vitro generated clinically relevant UHMWPE particles. Biomedical Materials And Engineering. 10(3–4), p. 229–240. Matthews, J. B., Besong, A. A., Green, T. R., Stone, M. H., Wroblewski, B. M., Fisher, J. and Ingham, E. 2000b. Evaluation of the response of primary human peripheral blood mononuclear phagocytes to challenge with in vitro generated clinically relevant UHMWPE particles of known size and dose. Journal Of Biomedical Materials Research. 52(2), p. 296–307. Matthews, J. B., Green, T. R., Stone, M. H., Wroblewski, B. M., FIsher, J .and Ingham, E. 2001. Comparison of the response of three human monocytic cell lines to challenge with polyethylene particles of known size and dose. Journal Of Materials Science: Materials n Medicine. 12(3), p. 249–258. McGill, I. 2005. Rare Earth Elements. Weinheim: Wiley-VCH. McKellop, H., Shen, F., Lu, B., Campbell, P. and Salovey, R. 1999. Development of an extremely wear-resistant ultra high molecular weight polythylene for total hip replacements. Journal Of Orthopaedic Research. 17(2), p. 157–167. Medley , J.B., Chan, F.W., Krygier, J.J. and Bobyn, J. D. 1996. Comparison of alloys and designs in a hip simulator study of metal on metal implants. Clinical Orthopaedics And Related Research. Aug(329 Suppl), p. 148-159. Menaa, C., Kurihara, N., and Roodman, G. D. 2000. CFU-GM-derived cells form osteoclasts at a very high efficiency. Biochemical And Biophysical Research Communications. 267(3), p. 943–946. Mercier, C. and Chabardes, P. 1994. Organometallic chemistry in industrial vitamin-a and vitamin-e synthesis. Pure And Applied Chemistry. 66(7), p. 1509–1518. Milosev, I., Kovac, S., Topolovec, M., Pisot, V. and Trebse, R. 2009. Total hip replacements with metal-on-metal bearings. Zdravniski Vestnik. 78(Supp. II), p. 34–40. Minkara, A.A., Westermann, R.W., Rosneck, J. and Lynch, T. S. 2018. Systematic review and meta-analysis of outcomes after hip arthroscopy in femoralacetabular impingement. American Journal Of Sports Medicine. Jan(1), p.036354651774947. Miyamoto , T., Ohneda, O., Arai, F., Iwamoto, K., Okada, S., Takagi, K., Anderson, D. M. and Suda, T. 2001. Bifurcation of osteoclasts and dendritic cells from common progenitors. Blood. 98(8), p. 2544–2554. Molini, L., Precerutti, M., Gervasio, A., Draghi, F. and Bianchi, S. 2011. Hip: Anatomy and US technique. Journal Of Ultrasound. 14(2), p. 99–108. Mont, M.A. and Hungerford, D. S. 1995. Nontraumatic avascular necrosis of the femoral-head. Journal Of Bone And Joint Surgery: American Volume.. 77A(3), p. 459–474. Mont, M., Ragland, P. S., Etienne, G., Seyler, T. M. and Schmalzried, T. P. 2006. Hip resurfacing arthroplasty. The Journal of the American Academy of Orthopaedic Surgeons. 14(8), p. 454–463. Moretti, B., Pesce, V., Maccagnano, G., Vicenti, G., Lovreglio, P., Soleo, L. and Apostoli, P. 2012. Peripheral neuropathy after hip replacement failure: is vanadium the culprit? Lancet. 379(9826). p. 1676. Morsi, E., Habib, M. E., Elseedy, A. and Eid, T. 2016. Revision of failed hip hemiarthroplasty: Classification, management, and follow-up. Journal Of Orthopaedics. 13(2), p. 63–68. Musib, M. and Saha, S. 2010. Effect of wear-debris particles on RAW 264.7 cells. Proceedings Of The 2010 IEEE 36th Annual Northeast Bioengineering Conference, 26-28 March 2010, New York, USA. New York: IEEE, p. 32 - 33. Narayan, V. S., Ernsberger, C. and King, R. 2009. Pin-on-Disk wear studies of antioxidant-stabilized UHMWPE materials. [Poster]. 55th Annual Meeting of the Orthopaedic Research Society, 22-25th Feb, Las Vegas. National Joint Registry. 2016. NJR reports 2016. [online]. [Accessed: 31 August 2014]. Available from: http://www.njrreports.org.uk/hips-primary-procedures-patient-characteristics/H05v1NJR?reportid=351A3B2E-F983-4D53-BC1E-D9A90DC93AAA&defaults=DC__Reporting_Period__Date_Range=%22MAX%22,J__Filter__Calendar_Year=%22MAX%22,H__Filter__Joint=%22Hip%22. National Joint Registry. 2017. 2017 14th Annual Report - National Joint Registry For England, Wales, Northern Ireland And The Isle Of Man. [online]. [Accessed: 31 August 2014]. Available from: http://www.njrreports.org.uk/Portals/0/PDFdownloads/NJR 14th Annual Report 2017.pdf. Navarro-Zarza, J. E., Villaseñor-Oviesb, P., Vargas, A., Canoso, J. J., Chiapas-Gasca, K., Hernández-Díaz, C., Saavedra, M. A. and Kalish, R. A. 2012. Clinical Anatomy of the Pelvis and Hip. Reumatologia Clinica. 8(SUPPL.2), p. 33–38. Nich, C., Goodman, S. B. and Hospital, T. 2014 The role of macrophages in the biological reaction to wear debris from joint replacements. Journal Of Long Term Effects Of Medical Implants. 24(4), p. 259–265. Niche, C., Sariali, el-H., Hannouche, D., Nizard, R., Witvoet, J., Sedel, L. and Bizot, P. 2003. Long-term results of alumina-on-alumina hip arthroplasty for osteonecrosis. Clinical Orthopaedics And Related Research. 417, p. 102–111. Nizard, R., Sedel, L., Christel, P. Meunier, A., Soudry, M. and Witviet, J. 1992. Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clinical Orthopaedics. Sept(282), p. 53 – 63. Noordin, S., Umer, M., Hafeez, K. and Nawaz, H. 2010. Developmental dysplasia of the hip. Orthopedic Reviews. 2(2), p. 19. Oral, E., Greenbaum. E. S., Malhi, A. S., Harris, W. H. and Muratoglu, O. K. 2005. Characterization of irradiated blends of α-tocopherol and UHMWPE. Biomaterials. 26(33), p. 6657–6663. Oral, E., Christensen, S. D., Malhi, A. S., Wannomae, K. K. and Muratoglu, O. K. 2006. Wear Resistance and Mechanical Properties of Highly Cross-linked, Ultrahigh-Molecular Weight Polyethylene Doped With Vitamin E. Journal Of Arthroplasty. 21(4), p. 580–591. Oral, E., Wannomae, K. K., Rowell, S. L. and Muratoglu, O. K. 2007. Diffusion of vitamin E in ultra-high molecular weight polyethylene. Biomaterials. 28(35), p. 5225–5237. Oral, E., Malhi, A. S., Wannomae, K. K. and Muratoglu, O. K. 2008. Highly Crosslinked UHMWPE with Improved Fatigue Resistance for Total Joint Arthroplasty. Journal Of Arthroplasty. 23(7), p. 1037–1044. Oral, E., Malhi, A. S. and Muratoglu, O. K. 2006. Mechanisms of decrease in fatigue crack propagation resistance in irradiated and melted UHMWPE. Biomaterials. 27(6), p. 917–925. Oral, E and Muratoglu, O. 2009. Chapter 18: Highly cross-linked UHMWPE doped with vitamin E. Kurtz, S. Ed. UHMWPE Biomaterials Handbook. 2nd Edition. San Diego: Elsevier academic press, p. 307 - 325. Pandit, H., Glyn-Jones, S., McLardy-Smith, P., Gundle, R., Whitwell, D., Gibbons, C.L.M., Ostlere, S., Athanasou, N, Gill, H.S. and Murray, D. W. 2008. Pseudotumours associated with metal-on-metal hip resurfacings. Journal Of Bone And Joint Surgery: British Volume. 90(7), p. 920–3. Pandit, H., Vlychou, M., Whitwell, D., Crook, D., Luqmani, R., Ostlere, S., Murray, D. W. and Athanasou, N. A. 2008. Necrotic granulomatous pseudotumours in bilateral resurfacing hip arthroplasties: evidence for a type IV immune response. Virchows Archiv. 453(5), p. 529 – 534. Peng, Z.B., Hu, B., Su, Q.D. and Qu, J. Z. 2003. Study on mechanism of rare earth PVC stabilizer. Journal Of Rare Earths. 21(3), p. 328–330. Pennekamp, P. H., Caicedo, M., Catelas, I., Kunze, J., Laurent, M. P., Hallab, N. J., and WImmer, M. A. 2009. Lanthanides induce Diverse Cell Responses in Murine Macrophages. [Poster]. 55th Annual Meeting of the Orthopaedic Research Society, 22-25th Feb, Las Vegas Peterson, E. D., Nemanich, J. P., Altenburg, A. and Cabenela, M. E. 2009. Hip arthroplasty after previous arthrodesis. Clinical Orthopaedics And Related Research, 467(11), p. 2880–2885. Petis, S., Howard, J. L., Lanting, B. L. and Vasarhelyi, E. M. 2015. Surgical approach in primary total hip arthroplasty: Anatomy, technique and clinical outcomes. Canadian Journal Of Surgery. 58(2), p. 128–139. Popoola, O.O., Yao, J.A.Q., Johnson, T.S. and Blanchard, C. R. 2010. Wear, Delamination, and Fatigue Resistance of Melt-Annealed Highly Cross linked UHMWPE Cruciate-Retaining Knee Inserts under Activities of Daily Living. Journal Of Orthopaedic Research. 28(9), p. 1120–1126. Premnath, V., Harris, W.H., Jasty, M. and Merrill, E. W. 1996. Gamma sterilization of UHMWPE articular implants: An analysis of the oxidation problem. Biomaterials. 17(18), p. 1741–1753. Proff, P. and Römer, P. 2009. The molecular mechanism behind bone remodelling: A review. Clinical Oral Investigations. 13(4), p. 355–362. Puertolas, J.A. and Kurtz, S. M. 2016. UHMWPE matrix composites. In: Kurtz, S. ed. Ultrahigh Molecular Weight Polyethylene In Total Joint Replacements And Medical Devicse. London: Elsevier, p. 369–397. Rader, C. P., Sterner, T., Jakob, F., Schütze, N and Eulert, J. 1999. Cytokine response of human macrophage-like cells after contact with polyethylene and pure titanium particles. Journal Of Arthroplasty. 14(7), p. 840–848. Raisz, L. G. 1988. Local and systematic factors in the pathogenesis of osteoporosis. The New England Journal Of Medicine. 298(6), p. 337–339. Raisz, L. G. 2005. Pathogenesis of osteoporosis : concepts , conflicts , and prospects. Journal Of Clinical Investigation. 115(12), p. 3318–3325. Richards, L., Brown, C., Stone, M. H., Fisher, J., Ingham, E. and Tipper, J. L. 2008. Identification of nanometre-sized ultra-high molecular weight polyethylene wear particles in samples retrieved in vivo. Journal Of Bone And Joint Surgery: British Volume. 90(issue), p. 1106–1113. Richards, L. (2008) The biological activity of nanometre sized polymer particles. Ph.D. thesis, University of Leeds. Roodman, G. D. 2012. Vitamin E: Good for the heart, bad for the bones? Nature Medicine. 18(4), p. 491–492. Scholes, S. C. and Unsworth, A. 2006. The effects of proteins on the friction and lubrication of artificial joints. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 220(6), p. 687–693. Schubert, D., Dargusch, R., Raitano, J. and Chan, S. W. 2006. Cerium and yttrium oxide nanoparticles are neuroprotective. Biochemical And Biophysical Research Communications. 342(1), p. 86–91. Shishido, T., Clarke, I. C., Weber, F., Shoji, H. and Imakiire, A. 2002. Analysis of retrieved THR cups of highly cross-linked UHMWPE from South Africa. [Poster]. 48th Annual Meeting of the Orthopaedic Research Society, Feb, Dallas, Texas. Silverman, E. J., Ashley, B. and Sheth, N. P. 2016. Metal-on-metal total hip arthroplasty: is there still a role in 2016? Current Reviews In Musculoskeletal Medicine. 9(1), p. 93–96. Singh, U., Devaraj, S. and Jialal, I. 2005. Vitamin E, oxidative stress, and inflammation. Annual Review Of Nutrition. p. 151–174. Siskey, R., Smelt, H., Boon-Ceelan, K. and Persson, M. 2016. UHMWPE homocomposites and fibers. Ultrahigh Molecular Weight Polyethylene In Total Joint Replacements And Medical Device. 225(1), p. 398 – 411. Smith, J. T. (2016) A 3d culture model to investigate cellular responses to mechanical loading in spinal cord injury. Ph.D. thesis, University of Leeds. Smolen, J., Aletaha, D. and McInnes, I. B. 2016. Rheumatoid arthritis. Lancet. 388(10055), p. 2023–2038. Sokol, R. J. 1993. Vitamin E deficiency and neurological disorders. In: Packer, L. and Fuchs, J. eds. Oxidants, Antioxidants And Free Radicals. New York: Marcel Dekker. Suñer, S., Gowland, N., Craven, R., Joffe, R., Emami, N. and Tipper, J. L. 2018. Ultrahigh molecular weight polyethylene/graphene oxide nanocomposites: Wear characterization and biological response to wear particles. Journal Of Biomedical Materials Research - Part B Applied Biomaterials. 106(1), p. 183–190. Sutula, L.C., Collier, J.P., Saum, K.A., Currier, B.H., Currier, J.H., Sanford, W.M., Mayor, M. B., Wooding, R. E., Sperling, D. K. and Williams, I. R. 1995. Impact of gamma-sterilization on clinical-performance of polyethylene in the hip. Clinical Orthopaedics And Related Research. 319(issue), p. 28–40. Teitelbaum, S. L. 2006. Osteoclasts and integrins. in Zaidi, M. (ed.) Skeletal Development And Remodeling In Health, Disease, And Aging. Oxford: Blackwell Publishing, pp. 95–99. Teng, G. G., Curtis, J. R. and Saag, K. G. 2008. Mortality and osteoporotic fractures: Is the link causal, and is it modifiable?. Clinical And Experimental Rheumatology. 26(5 SUPPL. 51), p. 125 - 137. Teramura, S., Sakoda, H., Terao, T., Endo, M. M., Fujiwara, K. and Tomita, N. 2009. Reduction of wear volume from accelerated aged UHMWPE knee components by the addition of vitamin E. Journal Of Biomechanical Science And Engineering. 4(4), p. 589–596. Tipper, J., Ingham, E., Jin, Z., and Fisher, J. 2005. The science of metal-on-metal articulation. Current Orthopaedics. 19(4), p. 280 – 287. Tipper, J.L., Galvin, A.L., Williams, S., McEwen, H.M.J., Stone, M.H., Ingham, E., and Fisher, J. 2006. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators. Journal Of Biomedical Materials Research Part A. 78(3), p. 473–480. Tipper, J. L., Firkins, P. J., Ingham, E., Fisher, J., Stone, M. H. and Farrar, R. 2000. Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses. Journal Of Materials Science: Materials In Medicine. 11(2), p. 117–124. Tonino, A. J., Thèrin, M. and Doyle, C. 1999. Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem. The Journal Of Bone And Joint Surgery: British volume. 81(1), p. 148–54. Traina, F., De Fine, M., and Affatato, S. 2012. Anatomy of the hip and suitable prostheses. Wear Of Orthopaedic Implants And Artificial Joints. 2013, p.93-114. Traina, F. De Fine, M., Di Martino, A. and Faldini, C. 2013. Fracture of ceramic bearing surfaces following total hip replacement: A systematic review. BioMed Research International. 2013, p. 157247. Tubby, A. H. 1908. A clinical lecture on coxa valga. British Medical Journal. 2(2482), p. 185. Vaidya, C., Alvarez, E., Vinciguerra, J., Bruce, D. A. and Desjardins, J. D. 2011. Reduction of total knee replacement wear with vitamin e blended highly cross-linked ultra-high molecular weight polyethylene. Proceedings Of The Institution Of Mechanical Engineers, Part H: Journal Of Engineering In Medicine. 225(1), p. 1–7. Vermes, C., Chandrasekaran, R., Jacobs, J. J., Galante, J. O., Roebuck, K. A., and Glant, T. T. 2001. The effects of particulate wear debris, cytokines, and growthfactors on the functions of MG-63 osteoblasts. The Journal Of Bone And Joint Surgery: American Volume. 83A(2), p. 201–211. Vignery, A. 2005. Macrophage fusion: are somatic and cancer cells possible partners? Medicine Science. 21(12), p. 1070–1075. Wang, A., Zeng, H., Yau, S.S., Essner, A., Manely, M. and Dumbleton, J. 2006. Wear, oxidation and mechanical properties of a sequentially irradiated and annealed UHMWPE in total joint replacement. Journal Of Physics D-Applied Physics. 39(15), p. 3213–3219. Wannomae, K. K., Christensen, S. D., Freiberg, A. A., Bhattacharyya, S., Harris, W. H. and Muratoglu, O. K. 2006. The effect of real-time aging on the oxidation and wear of highly cross-linked UHMWPE acetabular liners. Biomaterials. 27(9), p. 1980–1987. Wei, S., Kitaura, H., Zhou, P., Ross, F.P. and Teitelbaum, S. L. 2005. IL-1 mediates TNF-induced osteoclastogenesis. Journal Of Clinical Investigation. 115(2), p. 282–290. Weir, E.C., Lowik, C., Paliwal, I. and Insogna, K. L. 1996. Colony stimulating factor-1 plays a role in osteoclast formation and function in bone resorption induced by parathyroid hormone and parathyroid hormone-related protein. Journal Of Bone And Mineral Research. 11(10), p. 1474–1481. Williams, D. F. 1999. The Williams Dictionary Of Biomaterials. Liverpool, UK.: Liverpool University Press. Willmann, G. 1998. Ceramics for total hip replacement--what a surgeon should know. Orthopedics. 21(2), p. 173–177. Wolf, C., Lederer, K. and Muller, U. 2002. Tests of biocompatibility of alpha-tocopherol with respect to the use as a stabilizer in ultrahigh molecular weight polyethylene for articulating surfces in joint endoprostheses. Journal Of Materials Science: Materials In Medicine. 13(7), p. 701–705. Wolf, C., Lederer, K., Pfragner, R., Schauenstein, K., Ingolic, E. and Siegl, V. 2007. Biocompatibility of ultra-high molecular weight polyethylene (UHMW-PE) stabilized with α-tocopherol used for joint endoprostheses assessed in vitro. Journal Of Materials Science: Materials In Medicine. 18(6), p. 1247–1252. Wolfarth, D. L., Han, D. L., Bushar, G. and Parks, N. L. 1997. Separation and characterization of polyethylene wear debris from synovial fluid and tissue samples of revised knee replacements. Journal Of Biomedical Materials Research. 34(1), p. 57–61. Wu, J., Peng, Z. and Tipper, J. 2013. Mechanical properties and three-dimensional topological characterisation of micron, submicron and nanoparticles from artificial joints. Tribology Letters. 52(3), p. 449–460. Yavropoulou, M. P. and Yovos, J. G. 2008. Osteoclastogenesis--current knowledge and future perspectives. Journal Of Musculoskeletal & Neuronal Interactions. 8(June), p. 204–16. Zhang, W., Ouyang, H., Dass, C. R. and Xu, J. 2016. Current research on pharmacologic and regenerative therapies for osteoarthritis. Bone Research. 4(October), p. 15040 - 15054. Zheng, Y.Y., Cai, W.L., Fu, M.L., Wang, C.Y. and Zhang, X. 2005. Rare earth stearates as thermal stabilizers for rigid poly( vinyl chloride). Journal Of Rare Earths. 23(2), p. 172–177."],"dcterms:accessrights":["public"],"dc:title":["Development of a novel 3D in vitro model to measure cellular response to antioxidant doped highly cross-linked ultra high molecular weight polyethylene wear debris"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:33:12Z"}