{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:24272"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:24272","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"The Eﬀect of Surgical Alignment and Soft Tissue Constraints on the Kinematics, Contact Pressure and Wear of a Total Knee Replacement","abstract":"As life expectancy and activity levels increase so does demand on total knee replacements (TKRs). Previous studies have determined that poor alignment can result in pain, lower knee scores or increased wear. However alignment alone may not result in early failure. Instead it may be the combination of alignment and the soft tissue conditions within the knee that are important. The aim of this study was to investigate the eﬀect of the soft tissues and surgical alignment on the kinematics and wear of a ﬁxed bearing TKR. Experimental and computational studies were carried out under soft tissue and alignment conditions to reﬂect the range found in vivo. Previous studies have investigated the eﬀect of soft tissues within the knee and the eﬀect of component alignment as individual variables but not in combination. The higher tension soft tissue conditions resulted in lower displacements and signiﬁcantly lower wear. Surgical alignment also had a signiﬁcant eﬀect on the kinematics; a 10° posterior tibial slope dislocated under lower tension constraints. Rotational mismatch resulted in signiﬁcantly higher tibial rotation and abduction-adduction displacements, which can lead to knee pain and instability. The tibial slope and rotational mismatch alignment conditions resulted in signiﬁcantly higher wear rates than mechanical alignment or 4° varus joint line. Rotational mismatch should be kept within 4°, the tibial slope should be lower than 4° and the angle between components in the coronal plane should be restricted under kinematic alignment to reduce the rotations and wear. In conclusion, surgical alignment and soft tissue tensions signiﬁcantly aﬀected the kinematics and wear in this study. One limitation is that the eﬀect of these conditions on patient satisfaction is unknown. Further investigations should be carried out to determine adverse biomechanical conditions in diﬀerent TKR designs.","abstract_html":"As life expectancy and activity levels increase so does demand on total knee replacements (TKRs). Previous studies have determined that poor alignment can result in pain, lower knee scores or increased wear. However alignment alone may not result in early failure. Instead it may be the combination of alignment and the soft tissue conditions within the knee that are important. The aim of this study was to investigate the eﬀect of the soft tissues and surgical alignment on the kinematics and wear of a ﬁxed bearing TKR. Experimental and computational studies were carried out under soft tissue and alignment conditions to reﬂect the range found in vivo. Previous studies have investigated the eﬀect of soft tissues within the knee and the eﬀect of component alignment as individual variables but not in combination. The higher tension soft tissue conditions resulted in lower displacements and signiﬁcantly lower wear. Surgical alignment also had a signiﬁcant eﬀect on the kinematics; a 10° posterior tibial slope dislocated under lower tension constraints. Rotational mismatch resulted in signiﬁcantly higher tibial rotation and abduction-adduction displacements, which can lead to knee pain and instability. The tibial slope and rotational mismatch alignment conditions resulted in signiﬁcantly higher wear rates than mechanical alignment or 4° varus joint line. Rotational mismatch should be kept within 4°, the tibial slope should be lower than 4° and the angle between components in the coronal plane should be restricted under kinematic alignment to reduce the rotations and wear. In conclusion, surgical alignment and soft tissue tensions signiﬁcantly aﬀected the kinematics and wear in this study. One limitation is that the eﬀect of these conditions on patient satisfaction is unknown. Further investigations should be carried out to determine adverse biomechanical conditions in diﬀerent TKR designs.","abstract_has_math":false,"creators":["Johnston, Helena E."],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Abdelgaied, Abdellatif","Pandit, Hemant","Fisher, John","Jennings, Louise"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-03","date_published":"2019-03","updated_at":"2026-11-18T22:33:25Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.778713"],"render_values":[{"text":"uk.bl.ethos.778713","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/K029592/1"],"render_values":[{"text":"EP/K029592/1","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/24272/1/Thesis%20Final%20Submission.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A24272","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Abdelgaied, Abdellatif","Pandit, Hemant","Fisher, John","Jennings, Louise"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC","Leeds Alumni Fund","EPSRC Centre of Innovative Manufacturing of Medical Devices"]},{"key":"dc:creator","label":"Author","values":["Johnston, Helena E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-03"]},{"key":"dc:date.issued","label":"Date","values":["2019-03"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/24272/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] Shape-ﬁt cutting guides for total knee replacement lower operating time, raise patient satisfaction. Accessed 06.11.2015. [2] M. Abdel. Measured resection versus gap balancing for total knee arthroplasty. Clinical Orthopaedics and Related Research, 472:2016 – 2022, 2014. [3] M.P. Abdel and S.B. Haas. The unstable knee: Wobble and buckle. The Bone and Joint Journal, 96(B):112–114, 2014. [4] M.P. Abdel, S.P. Parratte, and N.C. Budhiparama. The patella in total knee arthroplasty: to resurface or not is the question. Curr Rev Musculoskelet Med., 7(2):117–124, 2014. [5] A. Abdelgaied, C. Brockett, F. Liu, L. Jennings, J. Fisher, and Z. Jin. Quantiﬁcation of the eﬀect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene. Proceedings of the Institution of Mechanical Engineers. Part H: Journal of Engineering in Medicine, 227(1):18 – 26, 2013. [6] A. Abdelgaied, C. Brockett, F. Liu, L. Jennings, Z. Jin, and J. Fisher. The eﬀect of insert conformity and material on total knee replacement wear. The Journal of Engineering in Medicine, 228:98–106, 2014. [7] A. Abdelgaied, J. Fisher, and L.M. Jennings. A comparison between electromechanical and pneumaticcontrolled knee simulators for the investigation of wear of total knee replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2017. [8] A. Abdelgaied, J. Fisher, and L.M. Jennings. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements. Journal of the Mechanical Behavior of Biomedical Materials, 78:282 – 291, 2018. [9] A. Abdelgaied, F. Liu, C. Brockett, L. Jennings, J. Fisher, and Z. Jin. Computational wear prediction of artiﬁcial knee joints based on a new wear law and formulation. Journal of Biomechanics, 44:1108–1116, 2011. [10] S. Aﬀatato. Displacement or force control knee simulators? variations in kinematics and in wear. Artiﬁcial Organs, 40(2):195 – 201, 2016. [11] S. Aﬀatato, B. Bordini, C. Fagnano, P. Taddei, A. Tinti, and A. Toni. Eﬀects of the sterilisation method on the wear of uhmwpe acetabular cups tested in a hip joint simulator. Biomaterials, 23:1439 – 1446, 2002. [12] M. Al-Hajjar, I. Leslie, J. Tipper, S. Williams, J. Fisher, and L. Jennings. Eﬀect of cup inclination angle during microseparation and rim loading on the wear of biolox delta ceramic-on-ceramic total hip replacement. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 95(2):263 – 268, 2010. [13] K. Anderson, K. Buehler, and D. Markel. Computer assisted navigation in total knee arthroplasty. The Journal of Arthroplasty, 20:132–138, 2005. [14] T.P. Andriacchi, E.J. Alexander, M.K. Toney, C. Dyrby, and J. Sum. A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. Journal of biomechanical engineering, 120:743–749, 1998. [15] J. Archard. Contact and rubbing of ﬂat surfaces. Journal of Applied Physics, 24(8):981 – 988, 1953. [16] H. Asano, A. Hoshino, and T.J. Wilton. Soft tissue tension in total knee arthroplasty. The journal of arthroplasty, 19:558–561, 2004. [17] P.I. Babazadeh, J.D. Stoney, K. Lim, and P.F.M. Choong. The relevance of ligament balancing in total knee arthroplasty: how important is it? a systematic review of the literature. Orthop Rev (Pavia), 1, 2009. [18] D. Baker, A. Bellare, and L. Pruitt. The eﬀects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. Journal of Biomedical Materials Research, 66A:146–154, 2003. [19] S.A. Banks, M.K. Harman, J. Bellemans, and W.A. Hodge. Making sense of knee arthroplasty kinematics: news you can use. J Bone Joint Surg Am, 85-A(Suppl 4):64–72, 2003. [20] P. Barnett and J. Fisher. Comparison of wear in a total knee replacement under diﬀerent kinematic conditions. Journal of Materials Science: Materials in Medicine, 12:1039 – 1042, 2001. [21] P. Barnett, H. McEwen, D. Auger, M. Stone, E. Ingham, and J. Fisher. Investigation of wear of knee prostheses in a new displacement/force-controlled simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 216(1):51 – 61, 2002. [22] R. Barrack, T. Schrader, A. Bertot, M. Wolfe, and L. Myers. Component rotation and anterior knee pain after total knee arthroplasty. Clinical Orthopaedics and Related Research, 392:46–55, 2001. [23] D. Bartel, J. Rawlinson, A. Burstein, C. Ranawat, and W. Flynn. Stresses in polyethylene components of contemporary total knee replacements. Clinical Orthopaedics and Related Research, 317:76–82, 1995. [24] H. Bathis, L. Perlick, M. Tingart, C. Luring, D. Zurakowski, and J. Grifka. Alignment in total knee arthroplasty: A comparison of computer-assisted surgery with the conventional technique. The Journal of Bone and Joint Surgery, 86-B:682–687, 2014. [25] L.E. Bayliss, D. Culliford, A.P. Monk, S. Glyn-Jones, D. Prieto-Alhambra, A. Judge, C. Cooper, A.J. Carr, N.K. Arden, and D.J. Beard. The eﬀect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study. The Lancet, 389:1424–1430, 2017. [26] S. Bell, P. Young, C. Drury, J. Smith, I. Anthony, B. Jones, M. Blyth, and A. McLean. Component rotational alignment in unexplained painful primary total knee arthroplasty. The Knee, 21:272–277, 2014. [27] J. Bellemans, P. D’Hooghe, H. Vandenneucker, G.V. Damme, and J. Victor. Soft tissue balance in total knee arthroplasty: does stress relaxation occur perioperatively? Clinical Orthopaedics and Related Research, 452:49–52, 2006. [28] M.G. Benedetti, F. Catani, T.W. Bilotta, M. Marcacci, E. Mariani, and S. Giannini. Muscle activation pattern and gait biomechanics after total knee replacement. Clinical Biomechanics, 18:871–876, 2003. [29] D.L. Benoit, D.K. Ramsey, M. Lamontagne, L. Xu, P. Wretenberg, and P. Renstrom. In vivo knee kinematics during gait reveals new rotation proﬁles and smaller translations. Clinical orthopaedics and related research, 454:81–88, 2007. [30] M. Berend, M. Ritter, H. Hyldahl, J. Meding, and R. Redelman. Implant migration and failure in total knee arthroplasty is related to body mass index and tibial component size. Journal of Arthroplasty, 23(6):104–109, 2008. [31] M. Berend, M. Ritter, J. Meding, P. Faris, E. Keating, R. Redelman, G. Faris, and K. Davis. The chitranjan ranawat award: Tibial component failure mechanisms in total knee arthroplasty. Clinical Orthopaedics and Related Research, 428:26–34, 2004. [32] M. Berend, M. Ritter, J. Meding, P. Faris, M. Keating, R. Redelman, G. Faris, and K. Davis. Tibial component failure mechanisms in total knee arthroplasty. Clinical Orthopaedics and Related Research, 428:26–34, 2004. [33] R. Berger, H. Rubash, J. Michael, W. Thompson, and S. Lawrence. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clinical Orthopaedics and Related Research, 286:40–47, 1993. [34] R.A. Berger, L.S. Crossett, J.J. Jacobs, and H.E. Rubash. Malrotation causing patellofemoral complications after total knee arthroplasty. Clinical Orthopaedics and Related Research, 356:144–153, 1998. [35] D. Bertolini, G. Nedwin, T. Bringman, D. Smith, and G. Mundy. Stimulation of bone resorption and inhibition of bone formation in vitro by human tumour necrosis factors. Nature, 319:516–518, 1986. [36] K.H. Bloemker, T.M. Guess, L. Maletsky, and K. Dodd. Computational knee ligament modelling using experimentally determined zero-load lengths. Open Biomed Eng J., 6:33–41, 2012. [37] G. Blunn, E. Brach del Preva, L. Costa, J. Fisher, and A. Freeman. Ultra high molecular-weight polyethylene (uhmwpe) in total knee replacement: Fabrication, sterilisation and wear. The Journal of Bone and Joint Surgery, 84:946–949, 2002. [38] M. Bolognesi and A. Hofmann. Computer navigation versus standard instrumentation for tka. Clinical Orthopaedics and Related Research, 440:162–169, 2005. [39] F. Bookstein. Landmark methods for forms without landmarks: morphometrics of group diﬀerences in outline shape. Medical Image Analysis, 1(3):225–243, 1996. [40] F. Bookstein, editor. Morphometric Tools for Landmark Data: Geometry and Biology. Cambridge University Press, 1997. [41] P. Bracco, V. Brunella, M. Luda, E. Brach del Prever, M. Zanetti, and L. Costa. Oxidation behaviour in prosthetic uhmwpe components sterilised with high energy radiation in a low oxygen environment. Journal of Othropaedic Traumatology, 91:3057–3064, 2006. [42] E. Brach del Prever, A. Bistolﬁ, P. Bracco, and L. Costa. Uhmwpe for arthroplasty: Past or future? Journal of Othropaedic Traumatology, 10:1–8, 2009. [43] G.W. Brick and R.D. Scott. The patellofemoral component of total knee arthroplasty. Clinical Orthopaedics and Related Research, 231:163–178, 1988. [44] C.L. Brockett, A. Abdelgaied, T. Haythornthwaite, C. Hardaker, J. Fisher, and L.M. Jennings. The inﬂuence of simulator input conditions on the wear of total knee replacements: An experimental and computational study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 230:429–439, 2016. [45] N. Budhiparama, M. Abdel, and S. Parratte. Icl 19: The importance of surgical technique in the outcome of tkr gap balancing vs measured resection technique for tkr: with speciﬁc reference to ﬁnal outcome, 2015. International Society of Arthroscopy, Knee Surgery and Orthopaedic Sports Medicine. [46] B. Carr and T. Goswami. Knee implants- review of models and biomechanics. Materials and Design, 30:398–413, 2009. [47] Arianna Cerquiglini, Johann Henckel, Harry S. Hothi, Lorenzo Dall’Ava, Paul Shearing, Michael T. Hirschmann, and Alister J. Hart. Computed tomography techniques help understand wear patterns in retrieved total knee arthroplasty. The Journal of Arthroplasty, 33(9):3030 – 3037, 2018. [48] C. Chang and C. Yang. Kinematic navigation in total knee replacement - experience from the ﬁrst 50 cases. Journal of the Formosan Medical Association, 105(6):468–474, 2006. [49] E. Chao, R. Laughman, E. Shneider, and R. Stauﬀer. Normative data of knee joint motion and ground reaction forces in adult level walking. Journal of Biomechanics, 16(3):219 – 233, 1983. [50] S. Chauhan, G. Clark, S. Lloyd, R. Scott, W. Breidahl, and J. Sikorski. Computer-assisted total knee replacement. The Journal of Bone and Joint Surgery, 86-B(6):818–823, 2004. [51] S. Chauhan, R. Scott, W. Breidahl, and R. Beaver. Computer-assisted knee arthroplasty versus a conventional jig-based technique. The Journal of Bone and Joint Surgery, 86-B(3):372–377, 2004. [52] Z. Chen, L. Wang, Y. Liu, J. He, Q. Lian, D. Li, and Z. Jin. Eﬀect of component mal-rotation on knee loading in total knee arthroplasty using multi-body dynamics modeling under a simulated walking gait. Journal of Orthopaedic Research, 33(9):1287–1296, 2015. [53] C. Cheng, C. Huang, J. Liau, and C. Huang. The inﬂuence of surgical malalignment on the contact pressures of ﬁxed and mobile bearing knee prostheses - a biomechanical study. Clinical Biomechanics, 18(3):231–236, 2003. [54] A. Cheung, S.K. Goh, A. Tang, and T.B. Keng. Complications of total knee arthroplasty. Current Orthopaedics, 22(4):274–283, 2008. [55] P. Chin, K. Yang, S. Yeo, and N. Lo. Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. The Journal of Arthroplasty, 20(5):618–626, 2005. [56] P. Choong, M. Dowsey, and J. Stoney. Does accurate anatomical alignment result in better function and quality of life? comparing conventional and computer-assisted total knee arthroplasty. The Journal of Arthroplasty, 24(4):560–569, 2009. [57] J. Collier, D. Sperling, J. Currier, L. Sutula, K. Saum, and M. Mayor. Impact of gamma sterilization on clinical performance of polyehtylene in the knee. The Journal of Arthroplasty, 11(4):377 – 389, 1996. [58] B. Daines and D. Dennis. Gap balancing vs. measured resection technique in total knee arthroplasty. Clinics in Orthopedic Surgery, 6:1 – 8, 2014. [59] F. Daubresse, C. Vajeu, and J. Loquet. Total knee arthroplasty with conventional or navigated technique: Comparison of the learning curves in a community hospital. Acta Orthopaedica Belg, 71:710–713, 2005. [60] A. Demulder, S.V. Suggs, K.M. Zsebo, T. Scarcez, and G.D. Roodman. Eﬀects of stem cell factor on osteoclast-like cell formation in long-term human marrow cultures. Journal of Bone and Mineral Research, 7(11):1337–1344, 1992. [61] D. Dennis, R. Komistek, R. Kim, and A. Sharma. Gap balancing versus measured resection technique for total knee arthroplasty. Clinical Orthopaedics and Related Research, 468:102–107, 2010. [62] J. DesJardins, P. Walker, H. Haider, and J. Perry. The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity. Journal of Biomechanics, 33:1231–1242, 2000. [63] H. Dossett, N. Estrada, G. Swartz, G. LeFevre, and B. Kwasman. A randomised controlled trial of kinematically and mechanically aligned total knee replacements. The Bone and Joint Journal, 96-B(7):907– 913, 2014. [64] M-J. Emami, M-H. Ghahramani, F. Abdinejad, and H. Namazi. Q-angle - an invaluable parameter for evaluation of anterior knee pain. Archives of Iranian Medicine, 10(1):24–26, 2007. [65] K. Ezzet, J. Hermida, C. Colwell Jr, and D. D’Lima. Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator. Clinical Orthopaedics and Related Research, 428:120–124, 2004. [66] K. Ezzet, J. Hermida, N. Steklov, and D. D’Lima. Wear of polyethylene against oxidized zirconium femoral components. The Journal of Arthroplasty, 27(1):116–120, 2012. [67] S. Fantozzi, F. Cantani, A. Ensini, A. Leardini, and S. Giannini. Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo ﬂuoroscopic analysis during activities of daily living. Journal of Orthopaedic Surgery and Research, 24(12):2222–2229, 2006. [68] E. Feng, S. Stulberg, and R. Wixon. Progressive subluxation and polyethylene wear in total knee replacements with ﬂat articular surfaces. Clinical Orthopaedics and Related Research, 299:60–71, 1994. [69] J. Fisher, L. Jennings, A. Galvin, Z. Jin, M. Stone, and E. Ingham. Polyethylene wear in total knees. Clinical Orthopaedics and Related Research, 468:12–18, 2010. [70] J. Fisher, H.M.J McEwen, J. Tipper, A.L. Galvin, J. Ingram, A. Kamali, M.H. Stone, and E. Ingham. Wear, debris, and biologic activity of cross-linked polyethylene in the knee: Beneﬁts and potential concerns. Clinical Orthopaedics and Related Research, 428:114–119, 2004. [71] B. Fregly, C. Marquez-Barrientos, S. Banks, and J. DesJardins. Increased conformity oﬀers diminishing returns for reducing total knee replacement wear. Journal of Biomechanical Engineering, 182:021007– 021007–7, 2010. [72] Benjamin J. Fregly, W.Gregory Sawyer, Melinda K. Harman, and Scott A. Banks. Computational wear prediction of a total knee replacement from in vivo kinematics. Journal of Biomechanics, 38(2):305 – 314, 2005. Knee Mechanics: An Update of Theoretical and Experimental Analyses. [73] T. Fukubayashi, P.A. Torzilli, M.F. Sherman, and R.F. Warren. An in vitro biomechanical evaluation of anterior-posterior motion of the knee. Journal of Bone and Joint Surgery, 64-A:258–264, 1982. [74] J.R. Funk, G.W. Hall, J.R. Crandall, and W.D. Pilkey. Linear and quasi-linear viscoelastic characterization of ankle ligaments. Journal of Biomechanical Engineering, 122(1):15–22, 1999. [75] A. Galvin, L. Kang, J. Tipper, M. Stone, E. Ingham, Z. Jin, and J. Fisher. Wear of crosslinked polyethylene under diﬀerent tribological conditions. Journal of Materials Science: Materials in Medicine, 17:235–243, 2006. [76] A. Galvin, L. Kang, I. Udoﬁa, L. Jennings, H. McEwen, Z. Jin, and J. Fisher. Eﬀect of conformity and contact stress on wear in ﬁxed-bearing total knee prostheses. Journal of Biomechanics, 42:1898–1902, 2009. [77] A. Galvin, J. Tipper, E. Ingham, and J. Fisher. Nanometre size wear debris generated from crosslinked and non-crosslinked ultra high molecular weight polyethylene in artiﬁcial joints. Wear, 259:977–983, 2006. [78] S. Gencur, C. Rimnac, and S. Kurtz. Failure micromechanisms during uniaxial tensile fracture of conventional and highly crosslinked ultra-high molecular weight polyethylenes used in total joint replacements. Biomaterials, 24:3947–3954, 2003. [79] J. Giﬃn, K. Stabile, T. Zantop, T. Vogrin, S. Woo, and C. Harner. Importance of tibial slope for stability of the posterior cruciate ligament-deﬁcient knee. The American Journal of Sports Medicine, 35(9):1443–1449, 2007. [80] J. Giﬃn, T. Vogrin, T. Zantop, T. Vogrin, S. Woo, and C. Harner. Eﬀects of increasing tibial slope on the biomechanics of the knee. The American Journal of Sports Medicine, 32(2):376–382, 2004. [81] A.C. Godest, M. Beaugonin, E. Huang, M. Taylor, and P.J. Gregson. Simulation of a knee joint replacement during a gait cycle using explicit ﬁnite element analysis. Journal of Biomechanics, 35(2):267–275, 2002. [82] A. Gomoll, T. Wanich, and A. Bellare. J-integral fracture toughness and tearing modulus measurement of radiation cross-linked uhmwpe. Journal of Orthopaedic Research, 20:1152–1156, 2002. [83] F.A. Gottschalk, S. Kourosh, M. Stills, B. McClellan, and J. Roberts. Does socket conﬁguration inﬂuence the position of the femur in above-knee amputation? Journal of Prosthestics and Orthotics, 2(1):94, 1989. [84] M. Gowen, D. Wood, E. Ihrie, M. McGuire, and G. Russel. An interleukin 1 like factor stimulates bone resorption in vitro. Nature, 306:378–380, 1983. [85] D. Grecu, I. Antoniac, O. Trante, M. Niculescu, and O. Lupescu. Failure analysis of retrieved polyethylene insert in total knee replacement. Biomaterials, 6:12–15, 2016. [86] F.M. Griﬃn, J.N. Insall, and G.R. Scuderi. Accuracy of soft tissue balancing in total knee arthroplasty. The Journal of Arthroplasty, 15:970–973, 2000. [87] Y. Gu, J. Roth, S. Howell, and M. Hull. How frequently do four methods for mechanically aligning a total knee arthroplasty cause collateral ligament imbalance and change alignment from normal in white patients? The Journal of Bone and Joint Surgery, 96-A(12), 2014. [88] K.A. Gustke, G.J. Golladay, M.W. Roche, G.J. Jerry, L.C. Elson, and C.R. Anderson. Increased satisfaction after total knee replacement using sensor-guided technology. The Bone and Joint Journal, 96-B(10):1333–1338, 2014. [89] R. Haaker, M. Stockheim, M. Kamp, G. Proﬀ, J. Breitenfelder, and A. Ottersbach. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clinical Orthopaedics and Related Research, 433:152–159, 2005. [90] H. Haider, L. Alberts, M. Laurent, T. Johnson, J. Yao, L. Gilbertson, P. Walker, J. Neﬀ, and K. Garvin. Comparison between force-controlled and displacement-controlled in-vitro wear testing on a widely used tkr implant. In Transactions of the annual meeting - orthopaedic research society, pages 1007–1007, 2002. [91] H. Haider, T. Sekundiak, and K. Garvin. Analysis and recommendations for the optimum spring conﬁgurations for soft tissue restraint in force-control knee simulator testing. 48th Annual Meeting of Orthopaedic Research Society, 2002. [92] H. Haider, P. Walker, J. DesJardins, and G. Blunn. Eﬀects of patient and surgical alignment variables on kinematics in tkr simulation under force-control. Journal of ASTM International, 3(10):3–16, 2006. [93] Hani Haider. Chapter 26 - tribological assessment of uhmwpe in the knee. In Steven M. Kurtz, editor, UHMWPE Biomaterials Handbook (Second Edition), pages 381 – 408. Academic Press, Boston, second edition edition, 2009. [94] J. Halloran, A. Petrella, and P. Rullkoetter. Explicit ﬁnite element modeling of total knee replacement mechanics. Journal of Biomechanics, 38:323–331, 2005. [95] M. Harman, J. DesJardins, S. Banks, L. Benson, M. Laberge, and W. Hodge. Damage patterns on polyethylene inserts after retrieval and after wear simulation. 47th Annual Meeting, Orthopaedic Research Society. Implant Wear., 2001. [96] P. Harvie, K. Sloan, and R. Beaver. Computer navigation vs conventional total knee arthroplasty; ﬁveyear functional results of a prospective randomized trial. The Journal of Arthroplasty, 27(5):667–672, 2012. [97] W. Healy, R. Lorio, and M. Lemos. Athletic activity after joint replacement. The American Journal of Sports Medicine, 3(29):377–388, 2001. [98] P.F. Hill, V. Vedi, A. Williams, H. Iwaki, V. Pinkserova, and M.A.R. Freeman. Tibiofemoral movement 2: the loaded and unloaded living knee studied by mri. The Journal of Bone and Joint Surgery, 82(B):1196– 1198, 2000. [99] S. Howell, S. Papadopoulos, K. Kuznik, and M. Hull. Accurate alignment and high function after kinematically aligned tka performed with generic instruments. Knee Surgery, Sports Traumatology, Arthroscopy, 0942-2056, 2013. [100] H. Hsu, A. Garg, P. Walker, M. Spector, and F. Ewald. Eﬀect of knee component alignment on tibial load distribution with clinical correlation. Clinical Orthopaedics and Related Research, 248:135–144, 1989. [101] T. Huang, L. Kuo, K. Peng, M. Lee, and R. Hsu. Computer tomography evaluation in total knee arthroplasty: Computer-assisted navigation versus conventional instrumentation in patients with advanced valgus arthritic knees. The Journal of Arthroplasty, 29:2363–2368, 2014. [102] D.E Hurwitz, A.B Ryals, J.P Case, J.A Block, and T.P Andriacchi. The knee adduction moment during gait in subjects with knee osteoarthritis is more closely correlated with static alignment than radiographic disease severity, toe out angle and pain. Journal of Orthopaedic Research, 20(1):101 – 107, 2002. [103] E. Ingham and J. Fisher. Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 214(1):21–37, 2000. [104] M. Ishikawa, S. Kuriyama, H. Ito, M. Furu, S. Nakamura, and S. Matsuda. Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: A case study on a single implant design. The Knee, 22:206–212, 2015. [105] H. Iwaki, V. Pinskerova, and M.A.R. Freeman. Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaverknee. The Journal of Bone and Joint Surgery, 82(B):1189–1195, 2000. [106] Faezeh Jahani. Modelling of dynamic edge loading in total hip replacements with ceramic on plyethylene bearings. PhD Thesis, 2017. [107] L. Jennings, M. Al-Hajjar, C. Brockett, S. Williams, J. Tipper, E. Ingham, and J. Fisher. Enhancing the safety and reliability of joint replacement implants. Orthopaedics and Trauma, 26(4):246 – 252, 2012. [108] Z. Jin, M. Stone, E. Ingham, and J. Fisher. Biotribology. Current Orthopaedics, 20:32 – 40, 2006. [109] T. Johnson, M. Laurent, J. Yao, and L. Gilbertson. The eﬀect of displacement control input parameters on tibiofemoral prosthetic knee wear. Wear, 250:222 – 226, 2001. [110] H. Jojima, L. Whiteside, and K. Ogata. Eﬀect of tibial slope or posterior cruciate ligament release on knee kinematics. Clinical Orthopaedics and Related Research, 426:194–198, 2004. [111] M. Jones and D. Scott, editors. Industrial Tribology: The Practical Aspects of Friction, Lubrication and Wear. North Holland [Imprint], 1983. [112] Cynthia A. Kahlenberg, Benedict U. Nwachukwu, Alexander S. McLawhorn, Michael B. Cross, Charles N. Cornell, and Douglas E. Padgett. Patient satisfaction after total knee replacement: A systematic review. HSS Journal ˆ A®, 14(2):192–201, Jul 2018. [113] A. Kanamori, J. Zeminski, T.W. Rudy, G. Li, F.H. Fu, and S.L-Y. Woo. The eﬀect of axial tibial torque on the function of the anterior cruciate ligament: a biomechanical study of a simulated pivot shift test. Arthroscopy: The Journal of Arthroscopic and Related Surgery, 18:394–398, 2002. [114] Kyoung-Tak Kang, Yong-Gon Koh, Juhyun Son, Oh-Ryong Kwon, Jun-Sang Lee, and Sae-Kwang Kwon. Inﬂuence of increased posterior tibial slope in total knee arthroplasty on knee joint biomechanics: A computational simulation study. The Journal of Arthroplasty, 2017. [115] K. Kato and K. Adachi, editors. Modern Tribology Handbook, Chapter 7. Wear Mechanisms. CRC Press, 2001. [116] L. Knight, S. Pal, J. Coleman, F. Bronson, H. Haider, D. Levine, M. Taylor, and P. Rullkoetter. Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading. Journal of Biomechanics, 40:1550–1558, 2006. [117] R. Komistek, D. Dennis, and M. Mahfouz. In vivo ﬂuoroscopic analysis of the normal human knee. Clinical Orthopaedics and Related Research, 410:69–81, 2003. [118] D. Kopeliovich. Mechanisms of wear. Accessed 28.01.2016. [119] S. Kurtz, editor. The UHMWPE Handbook. Elsevier, 2004. [120] S. Kurtz, editor. UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyetheylene in Total Joint Replacement and Medical Devices. Elsevier, 2016. [121] S. Kurtz, C. Jewetta, J. Bergstroma, J. Fouldsa, and A. Edidin. Miniature specimen shear punch test for uhmwpe used in total joint replacements. Journal of Biomaterials, 23:1907–1919, 2002. [122] S. Kurtz, K. Ong, E. Lau, F. Mowat, and M. Halpern. Projections of primary and revision hip and knee arthroplasty in the united states from 2005 to 2030. JBJS, 89:780–785, 2007. [123] M. Lafortune, P. Cavanagh, H. Sommer, and A. Kalenak. Three-dimensional kinematics of the human knee during walking. Journal of Biomechanics, 25(4):347 – 357, 1992. [124] Yong Seuk Lee, Stephen M. Howell, Ye-Yeon Won, O-Sung Lee, Seung Hoon Lee, Hamed Vahedi, and Seow Hui Teo. Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy, 25(11):3467–3479, Nov 2017. [125] G. Lewis. Properties of crosslinked ultra-high-molecular-weight polyethylene. Biomaterials, 22:371–401, 2001. [126] J. Liau, C. Cheng, C. Huang, and W. Lo. The eﬀect of malalignment on stresses in polyethylene component of total knee prostheses - a ﬁnite element analysis. Clinical Biomechanics, 17:140–146, 2002. [127] L. Longstaﬀ, K. Sloan, N. Stamp, M. Scaddan, and R. Beaver. Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. The Journal of Arthroplasty, 24(4):570–578, 2009. [128] J. Lorenzo, S. Sousa, J. Foriseca, J. Hock, and E. Medlock. Colony-stimulating factors regulate the development of multinicleated osteoclasts from recently replicated cells in vitro. Journal of Clinical Investigation, 80:160–164, 1987. [129] S. Maruyuna, S. Yoshiya, N. Matsui, R. Kuroda, and M. Kurosaka. Functional comparison of posterior cruciate-retaining versus posterior stabilized total knee arthroplasty. Journal of Arthroplasty, 19:349–353, 2004. [130] J. Mason, T. Fehring, R. Estok, D. Banel, and K. Fahrbach. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. The Journal of Arthroplasty, 22:1097–1106, 2007. [131] P. Massin and A. Gournay. Optimization of the posterior condylar oﬀset, tibial slope, and condylar roll-back in total knee arthroplasty. The Journal of Arthroplasty, 21(6):889–896, 2006. [132] H. McEwen, P. Barnett, C. Bell, R. Farrar, D. Auger, M. Stone, and J. Fisher. The inﬂuence of design, materials and kinematics on the in vitro wear of total knee replacements. The Journal of Biomechanics, 38:357–365, 2005. [133] Peter J. McNair, Mark G. Boocock, Nicholas D. Dominick, Richard J. Kelly, Bill J. Farrington, and Simon W. Young. A comparison of walking gait following mechanical and kinematic alignment in total knee joint replacement. The Journal of Arthroplasty, 33(2):560 – 564, 2018. [134] S.P. Mell, S. Fullam, M.A. Wimmer, and H.J. Lundberg. Sensitivity of total knee replacement wear to tibial component malrotation. In Transactions of the annual meeting - orthopaedic research society, 2009. [135] S.P. Mell, M.A. Wimmer, J.J. Jacobs, and H.J. Lundberg. Total knee replacement wear is most sensitive to transverse plane alignment - a parametric ﬁnite element study. In Transactions of the annual meeting - orthopaedic research society, 2009. [136] R.L. Merkow, M. Soudry, and J.N. Insall. Patellar dislocation following total knee replacement. The Journal of Bone and Joint Surgery, American Volume, 67(9):1321–1327, 1985. [137] H. Mizu-uchi, S. Matsuda, H. Miura, K. Okazaki, Y. Alasaki, and Y. Iwamoto. The evaluation of postoperative alignment in total knee replacement using a ct-based navigation system. The Journal of Bone and Joint Surgery, 90-B(8):1025–1031, 2008. [138] Y. Mizuno, M. Kumagai, S.M. Mattessich, J.J. Elias, N. Ramrattan, A.J. Cosgarea, and E.Y.S. Chao. Qangle inﬂuences tibiofemoral and patellofemoral kinematics. Journal of Orthopaedic Research, 19(5):834– 840, 2001. [139] Matthew F. Moran, Saﬁa Bhimji, Joseph Racanelli, and Stephen J. Piazza. Computational assessment of constraint in total knee replacement. Journal of Biomechanics, 41(9):2013 – 2020, 2008. [140] J. Moreland. Mechanisms of failure in total knee arthroplasty. Clinical Orthopaedics and Related Research, 226:49–64, 1988. [141] J. Morrison. The mechanics of the knee joint in relation to normal walking. Journal of Biomechanics, 3:51–61, 1970. [142] E. Most, S. Zayontz, G. Li, E. Otterberg, K. Sabbag, and H.E. Rubash. Femoral rollback after cruciateretaining and stabilizing total knee arthroplasty. Clinical Orthopaedics and Related Research, 410:101– 113, 2003. [143] A. Mouttet and V. Sourdet. Europ total knee prosthesis with or without posterior cruciate ligament retention? comparative study at mid-term follow-up. Orthopaedics and Traumatology: Surgery and Research, 100:895–900, 2014. [144] V. Musahl, K.M. Bell, A.G. Tsai, R.S. Costic, R. Allaire, T. Zantop, J.J. Irrgang, and F.H. Fu. Development of a simple device for measurement of rotational knee laxity. Knee Surgery, Sports Traumatology, Arthroscopy, 15:1009–1012, 2007. [145] Y. Nagano, K. Naito, Y. Saho, S. Torii, T. Ogata, K. Nakazawa, M. Akai, and T. Fukubayashi. Association between in vivo knee kinematics during gait and the severity of knee osetoarthritis. The Knee, 19:628–632, 2012. [146] S. Nakagawa, Y. Kadoya, S. Todo, A. Kobayashi, H. Sakamoto, M.A.R. Freeman, and Y. Yamano. Tibiofemoral movement 3: full ﬂexion in the living knee studied by mri. The Journal of Bone and Joint Surgery, 82(B):1199–1200, 2000. [147] J. Nevelos, E. Ingham, C. Doyle, A. Nevelos, and J. Fisher. The inﬂuence of acetabular cup angle on the wear of ”biolox forte”alumina ceramic bearing couples in a hip joint simulator. Journal of Materials Science: Materials in Medicine, 12:141 – 144, 2001. [148] D. Nicoll and D. Rowley. International rotational error of the tibial component is a major cause of pain after total knee replacement. The Journal of Bone and Joint Surgery, 92-B:1238–1244, 2010. [149] NJR. National joint registry for england, wales, northern ireland and the isle of man: 13th annual report. 2006. [150] NJR. National joint registry for england, wales, northern ireland and the isle of man: 15th annual report. 2018. [151] T.L. Norman, J. Hutchison, M.R. Gardner, and J.D. Blaha. Knee loading due to varus and external rotation in gait supports medial compartment wear in total knee arthroplasty. The Scientiﬁc Pages of Orthopedics and Rheumatism, 1(1):8–18, 2017. [152] W. Norman Scott, editor. Insall and Scott Surgery of the Knee. Elsevier, 5 edition, 2012. [153] W. Norman Scott, editor. Insall and Scott Surgery of the Knee, Volume II. Elsevier, 6 edition, 2018. [154] O.D. Noyes, F.R. abd Schipplein, T.P. Andriacchi, S.R. Saddemi, and M. Welse. The anterior cruciate ligament-deﬁcient knee with varus alignment: An analysis of gait adaptations and dynamic joint loadings. The American Journal of Sports Medicine, 20(6):707–716, 1992. [155] Knee Restoration Center of Indiana. Anatomy. Accessed 28.01.19. [156] C. Olcott and R. Scott. Femoral component rotation during total knee arthroplasty. Clinical Orthopaedics and Related Research, 367:39–42, 1999. [157] M.W. Pagnano, A.D. Hanssen, D.G. Lewallen, and M.J. Stuart. Flexion instability after primary posterior cruciate retaining total knee arthroplasty. Clinical Orthopaedics and Related Research, 356:39–46, 1998. [158] J. Parizi, R.M. Nunley, K.R. Berend, A.V. Lombardi Jr, E.L. Ruth, and J.C. Clohisy. High level of residual symptoms in young patients after total knee arthroplasty. Clinical Orthopaedics and Related Research, 472(1):133–137, 2014. [159] S. Parratte and M.W. Pagnano. Eﬀect of postoperative mechanical axis alignment on the ﬁfteen year survival of modern cemented total knee replacements. The Journal of Bone and Joint Surgery, 92(12):2143– 2149, 2010. [160] E. Pena, B. Calvo, M.A. Martinez, and M. Doblare. A three-dimensional ﬁnite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint. Journal of Biomechanics, 39(9):1686 – 1701, 2006. [161] D. Pereira, F. Jaﬀe, and C. Ortiguera. Posterior cruciate ligament-sparing versus posterior cruciate ligament-sacriﬁcing arthroplasty. Journal of Arthroplasty, 13:138–144, 1998. [162] A. Perillo-Marcone and M. Taylor. Eﬀect of varus/valgus malalignment on bone strains in the proximal tibia after tkr: An explicit ﬁnite element study. Journal of Biomechanical Engineering, 129(1):1–11, 2006. [163] S. Pickering and D. Armstrong. Alignment in total knee replacement. The Journal of Bone and Joint Surgery, 468, 2012. URL http://www.boneandjoint.org.uk/content/focus/alignment-total-knee-replacement Accessed 27.10.2015. [164] C. Plaskos, A. Hodgson, K. Inkpen, and R. McGraw. Bone cutting errors in total knee arthroplasty. The Journal of Arthroplasty, 17(6):698–705, 2002. [165] Tobias Pohlen. Fourier descriptor. Accessed 19.12.17. [166] L. Pruitt. Deformation, yielding, fracture and fatigue behaviour of conventional and highly cross-linked ultra high molecular weight polyethylene. Biomaterials, 26:905–915, 2005. [167] S. Puloski, R. McCalden, S. MacDonald, C. Rorabeck, and R. Bourne. Tibial post wear in posterior stabilized total knee arthroplasty. Journal of Bone and Joint Surgery, 83:390–397, 2001. [168] E. Rabinowicz. The least wear. Wear, 100:533 – 541, 1984. [169] C.S. Ranawat. The patellofemoral joint in total condylar knee arthroplasty. pros and cons based on ﬁveto ten-year follow-up observations. Clinical Orthopaedics and Related Research, 205:93–99, 1986. [170] Amin S., N. Luepongsak, C.A. McGibbon, M.P. LaValley, D.E. Krebs, and D.T. Felson. Knee adduction moment and development of chronic knee pain in elders. Arthritis and Rheumatism (Arthritis care and research), 51(3):371–376, 2004. [171] T. Sando, R. McCalden, R. Bourne, S. MacDonald, and L. Somerville. Ten-year results comparing posterior cruciate-retaining versus posterior cruciate-substituting total knee arthroplasty. Journal of Arthroplasty, 30:210–215, 2015. [172] W. Schroer, K. Berend, A. Lombardi, C. Barnes, M. Bolognesi, M. Berend, M. Ritter, and R. Nunley. Why are total knees failing today? etiology of total knee revision in 2010 and 2011. The Journal of Arthroplasty, 28:116–119, 2013. [173] T. Schwenke, C. Kaddick, E. Schneider, and M. Wimmer. Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine, 219(6):457 – 64, 2005. [174] T. Schwenke, D. Orozco, E. Schneider, and M. Wimmer. Diﬀerences in wear between load and displacement control tested total knee replacements. Wear, 267(5-8):757 – 762, 2009. [175] G.R. Scuderi and J.N Insall. Total knee arthroplasty. current clinical perspectives. Clinical Orthopaedics and Related Research, 276:26–32, 1992. [176] SharcNet. Choosing between linear and higher order elements. Accessed 14.11.18. [177] SharcNet. Degenerated shape elements. Accessed 14.11.18. [178] P. Sharkey, W. Hozack, R. Rothman, S. Shastri, and S. Jacoby. Why are total knee arthroplasties failing today? Clinical Orthopaedics and Related Research, 404:7–13, 2002. [179] K. Shelburne, H. Kim, W. Sterett, and M. Pandy. Eﬀect of posterior tibial slope on knee biomechanics during functional activity. Journal of Orthopaedic Research, 29:223–231, 2011. [180] R. Shenoy, P.S. Pastides, and D. Nathwani. (iii) biomechanics of the knee and tkr. Orthopaedics and Trauma, 27(6):364 – 371, 2013. [181] Omer Slevin, Anna Hirschmann, Filippo F. Schiapparelli, Felix Amsler, Rolf W. Huegli, and Michael T. Hirschmann. Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3d-ct. Knee Surgery, Sports Traumatology, Arthroscopy, Oct 2017. [182] C.R Smith, M.F. Vifnos, R.L. Lenhart, J. Kaiser, and D.G. Thelen. The inﬂuence of component alignment and ligament properties on tibiofemoral contact forces in total knee replacement. Journal of Biomechanical Engineering, 138(2), 2016. [183] H.J. Sommer. Polygeom.m. Accessed 29.01.18. [184] A. Srivastava, G. Lee, N. Steklov, C. Colwell Jr., K. Ezzet, and D. D’Lima. Eﬀect of tibial component varus on wear in total knee arthroplasty. The Knee, 19(5):560–563, 2012. [185] British Standard. Geometric product speciﬁcations (gps) - surface texture: Proﬁle method - nominal characteristics of contact (stylus) instruments. ISO, 3274, 1998. [186] British Standard. Implants for Surgery - Wear of Total Knee-joint Prostheses, Part 1: Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test, 2009. 14243-1. [187] British Standard. Implants for Surgery - Wear of Total Knee-joint Prostheses, Part 2: Methods of Measurement, 2009. 14243-2. [188] British Standard. Implants for Surgery - Wear of Total Knee-joint Prostheses, Part 3: Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test, 2014. 14243-3. [189] D-S. Suh, K-T. Kang, J. Son, O-R. Kwon, C. Baek, and Y-G. Koh. Computational study on the eﬀect of malalignment of the tibial component on the biomechanics of total knee arthroplasty. Bone and Joint Research, 6(11), 2017. [190] M. Sundfelt, L. Carlsson, C. Johansson, P. Thomsen, and C. Gretzer. Asceptic loosening, not only a question of wear. Acta Orthopaedica, 77:177–197, 2006. [191] M. Tanzer. Posterior stabilized versus cruciate retaining total knee arthroplasty. Journal of Arthroplasty, 17:813–819, 1970. [192] P. Trent and P. Walker. Wear and conformity in total knee replacement. Wear, 36:175–187, 1976. [193] K. Valkering, S. Breugem, M. van den Bekerom, W. Tuinebreijer, and R. van Geenen. Eﬀect of rotational alignment on outcome of total knee arthroplasty. Acta Orthopaedica, 86(4):432–439, 2015. [194] M. Van Houtem, R. Clough, A. Khan, M. Harrison, and G. Blunn. Validation of the soft tissue restraints in a force-controlled knee simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 220(3):449–456, 2006. [195] Pieter-Jan T.K. Vandekerckhove, Matthew G. Teeter, Douglas D.R. Naudie, James L. Howard, Steven J. MacDonald, and Brent A. Lanting. The impact of coronal plane alignment on polyethylene wear and damage in total knee arthroplasty: A retrieval study. The Journal of Arthroplasty, 32(6):2012 – 2016, 2017. [196] P. Walker and H. Haider. Characterizing the motion of total knee replacements in laboratory tests. Clinical Orthopaedics and Related Research, 410:54–68, 2003. [197] P.S. Walker, G.W. Blunn, D.R. Broome, J. Perry, A. Watkins, S. Sathasivam, M.E. Dewar, and J.P. Paul. A knee simulating machine for performance evaluation of total knee replacements. Journal of Biomechanics, 30:83–89, 1997. [198] P.S. Warren, T.K. Olanlokun, A.G. Cobb, P.S. Walker, and B. Iverson. Laxity and function in knee replacements: A comparative study of three prosthetic designs. Clinical Orthopaedics and Related Research, 305:200–228, 1994. [199] R.C. Wasielewski, D.D. Galat, and R.D. Komistek. Correlation of compartment pressure data from an intraoperative sensing device with postoperative ﬂuoroscopic kinematic results in tka patients. Journal of Biomechanics, 38(2):333–339, 2005. [200] G. Waslewski, B. Marson, and J. Benjamin. Early, incapacitating instability of posterior cruciate ligament-retaining total knee arthroplasty. Journal of Arthroplasty, 13:763–767, 1998. [201] F. Werner, D. Ayers, L. Maletsky, and P. Rullkoetter. The eﬀect of varus/valgus malalignment on load distribution in total knee replacements. Journal of Biomechanics, 38:349–355, 2005. [202] S. White, R. Paxson, M. Tanner, and L. Whiteside. Eﬀects of sterilization on wear in total knee arthroplasty. Clinical Orthopaedics and Related Research, (331):164 – 171, 1996. [203] R. Willing and I. Kim. Three dimensional shape optimization of total knee replacements for reduced wear. Journal of Structural and Multidisciplinary Optimization, Medical and Bioengineering Application, 38:405–414, 2008. [204] R. Willing and I.Y. Kim. A holistic numerical model to predict strain hardening and damage of uhmwpe under multiple total knee replacement kinematics and experimental validation. Journal of Biomechanics, 42(15):2520–2527, 2009. [205] Huseyin S. Yercan, Tarik Ait Si Selmi, Tahir S. Sugun, and Philippe Neyret. Tibiofemoral instability in primary total knee replacement: A review, part 1: Basic principles and classiﬁcation. The Knee, 12(4):257–266, 2005. [206] J. Yim, E. Song, M. Khan, Z. Sun, and J. Seon. A comparison of classical and anatomical total knee alignment methods in robotic total knee arthroplasty. The Journal of Arthroplasty, 28:932–937, 2013. [207] D. Zhao, H. Sakoda, W. Sawyer, and B. Fregly. Predicting knee replacement damage in a simulator machine using a computational model with a consistent wear factor. Journal of Biomechanical Engineering, 130, 2008. [208] M. Zihlmann, A. Stacoﬀ, J. Romero, I. Quervain, and E. Stussi. Biomechanical background and clinical observations of rotational malalignment in tka: Literature review and consequences. Clinical Biomechanics, 20:661–668, 2005. [209] M. Zumstein, L. Frauchiger, D. Wyss, R. Hess, and P. Ballmer. Is restricted femoral navigation suﬃcient for accuracy of total knee arthroplasty? Clinical Orthopaedics and Related Research, 451:80–86, 2006."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.778713"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/K029592/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/24272/1/Thesis%20Final%20Submission.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["As life expectancy and activity levels increase so does demand on total knee replacements (TKRs). Previous studies have determined that poor alignment can result in pain, lower knee scores or increased wear. However alignment alone may not result in early failure. Instead it may be the combination of alignment and the soft tissue conditions within the knee that are important. The aim of this study was to investigate the eﬀect of the soft tissues and surgical alignment on the kinematics and wear of a ﬁxed bearing TKR. Experimental and computational studies were carried out under soft tissue and alignment conditions to reﬂect the range found in vivo. Previous studies have investigated the eﬀect of soft tissues within the knee and the eﬀect of component alignment as individual variables but not in combination. The higher tension soft tissue conditions resulted in lower displacements and signiﬁcantly lower wear. Surgical alignment also had a signiﬁcant eﬀect on the kinematics; a 10° posterior tibial slope dislocated under lower tension constraints. Rotational mismatch resulted in signiﬁcantly higher tibial rotation and abduction-adduction displacements, which can lead to knee pain and instability. The tibial slope and rotational mismatch alignment conditions resulted in signiﬁcantly higher wear rates than mechanical alignment or 4° varus joint line. Rotational mismatch should be kept within 4°, the tibial slope should be lower than 4° and the angle between components in the coronal plane should be restricted under kinematic alignment to reduce the rotations and wear. In conclusion, surgical alignment and soft tissue tensions signiﬁcantly aﬀected the kinematics and wear in this study. One limitation is that the eﬀect of these conditions on patient satisfaction is unknown. Further investigations should be carried out to determine adverse biomechanical conditions in diﬀerent TKR designs."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["The Eﬀect of Surgical Alignment and Soft Tissue Constraints on the Kinematics, Contact Pressure and Wear of a Total Knee Replacement"]}]}],"canonical_facts":{"dc:contributor.advisor":["Abdelgaied, Abdellatif","Pandit, Hemant","Fisher, John","Jennings, Louise"],"dc:contributor.sponsor":["EPSRC","Leeds Alumni Fund","EPSRC Centre of Innovative Manufacturing of Medical Devices"],"dc:creator":["Johnston, Helena E."],"dc:date":["2019-03"],"dc:date.issued":["2019-03"],"dc:description.abstract":["As life expectancy and activity levels increase so does demand on total knee replacements (TKRs). Previous studies have determined that poor alignment can result in pain, lower knee scores or increased wear. However alignment alone may not result in early failure. Instead it may be the combination of alignment and the soft tissue conditions within the knee that are important. The aim of this study was to investigate the eﬀect of the soft tissues and surgical alignment on the kinematics and wear of a ﬁxed bearing TKR. Experimental and computational studies were carried out under soft tissue and alignment conditions to reﬂect the range found in vivo. Previous studies have investigated the eﬀect of soft tissues within the knee and the eﬀect of component alignment as individual variables but not in combination. The higher tension soft tissue conditions resulted in lower displacements and signiﬁcantly lower wear. Surgical alignment also had a signiﬁcant eﬀect on the kinematics; a 10° posterior tibial slope dislocated under lower tension constraints. Rotational mismatch resulted in signiﬁcantly higher tibial rotation and abduction-adduction displacements, which can lead to knee pain and instability. The tibial slope and rotational mismatch alignment conditions resulted in signiﬁcantly higher wear rates than mechanical alignment or 4° varus joint line. Rotational mismatch should be kept within 4°, the tibial slope should be lower than 4° and the angle between components in the coronal plane should be restricted under kinematic alignment to reduce the rotations and wear. In conclusion, surgical alignment and soft tissue tensions signiﬁcantly aﬀected the kinematics and wear in this study. One limitation is that the eﬀect of these conditions on patient satisfaction is unknown. Further investigations should be carried out to determine adverse biomechanical conditions in diﬀerent TKR designs."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.778713"],"dc:identifier.grantnumber":["EP/K029592/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/24272/1/Thesis%20Final%20Submission.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/24272/"],"dc:relation.references":["[1] Shape-ﬁt cutting guides for total knee replacement lower operating time, raise patient satisfaction. Accessed 06.11.2015. [2] M. Abdel. Measured resection versus gap balancing for total knee arthroplasty. Clinical Orthopaedics and Related Research, 472:2016 – 2022, 2014. [3] M.P. Abdel and S.B. Haas. The unstable knee: Wobble and buckle. The Bone and Joint Journal, 96(B):112–114, 2014. [4] M.P. Abdel, S.P. Parratte, and N.C. Budhiparama. The patella in total knee arthroplasty: to resurface or not is the question. Curr Rev Musculoskelet Med., 7(2):117–124, 2014. [5] A. Abdelgaied, C. Brockett, F. Liu, L. Jennings, J. Fisher, and Z. Jin. Quantiﬁcation of the eﬀect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene. Proceedings of the Institution of Mechanical Engineers. Part H: Journal of Engineering in Medicine, 227(1):18 – 26, 2013. [6] A. Abdelgaied, C. Brockett, F. Liu, L. Jennings, Z. Jin, and J. Fisher. The eﬀect of insert conformity and material on total knee replacement wear. The Journal of Engineering in Medicine, 228:98–106, 2014. [7] A. Abdelgaied, J. Fisher, and L.M. Jennings. A comparison between electromechanical and pneumaticcontrolled knee simulators for the investigation of wear of total knee replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2017. [8] A. Abdelgaied, J. Fisher, and L.M. Jennings. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements. Journal of the Mechanical Behavior of Biomedical Materials, 78:282 – 291, 2018. [9] A. Abdelgaied, F. Liu, C. Brockett, L. Jennings, J. Fisher, and Z. Jin. Computational wear prediction of artiﬁcial knee joints based on a new wear law and formulation. Journal of Biomechanics, 44:1108–1116, 2011. [10] S. Aﬀatato. Displacement or force control knee simulators? variations in kinematics and in wear. Artiﬁcial Organs, 40(2):195 – 201, 2016. [11] S. Aﬀatato, B. Bordini, C. Fagnano, P. Taddei, A. Tinti, and A. Toni. Eﬀects of the sterilisation method on the wear of uhmwpe acetabular cups tested in a hip joint simulator. Biomaterials, 23:1439 – 1446, 2002. [12] M. Al-Hajjar, I. Leslie, J. Tipper, S. Williams, J. Fisher, and L. Jennings. Eﬀect of cup inclination angle during microseparation and rim loading on the wear of biolox delta ceramic-on-ceramic total hip replacement. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 95(2):263 – 268, 2010. [13] K. Anderson, K. Buehler, and D. Markel. Computer assisted navigation in total knee arthroplasty. The Journal of Arthroplasty, 20:132–138, 2005. [14] T.P. Andriacchi, E.J. Alexander, M.K. Toney, C. Dyrby, and J. Sum. A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. Journal of biomechanical engineering, 120:743–749, 1998. [15] J. Archard. Contact and rubbing of ﬂat surfaces. Journal of Applied Physics, 24(8):981 – 988, 1953. [16] H. Asano, A. Hoshino, and T.J. Wilton. Soft tissue tension in total knee arthroplasty. The journal of arthroplasty, 19:558–561, 2004. [17] P.I. Babazadeh, J.D. Stoney, K. Lim, and P.F.M. Choong. The relevance of ligament balancing in total knee arthroplasty: how important is it? a systematic review of the literature. Orthop Rev (Pavia), 1, 2009. [18] D. Baker, A. Bellare, and L. Pruitt. The eﬀects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. Journal of Biomedical Materials Research, 66A:146–154, 2003. [19] S.A. Banks, M.K. Harman, J. Bellemans, and W.A. Hodge. Making sense of knee arthroplasty kinematics: news you can use. J Bone Joint Surg Am, 85-A(Suppl 4):64–72, 2003. [20] P. Barnett and J. Fisher. Comparison of wear in a total knee replacement under diﬀerent kinematic conditions. Journal of Materials Science: Materials in Medicine, 12:1039 – 1042, 2001. [21] P. Barnett, H. McEwen, D. Auger, M. Stone, E. Ingham, and J. Fisher. Investigation of wear of knee prostheses in a new displacement/force-controlled simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 216(1):51 – 61, 2002. [22] R. Barrack, T. Schrader, A. Bertot, M. Wolfe, and L. Myers. Component rotation and anterior knee pain after total knee arthroplasty. Clinical Orthopaedics and Related Research, 392:46–55, 2001. [23] D. Bartel, J. Rawlinson, A. Burstein, C. Ranawat, and W. Flynn. Stresses in polyethylene components of contemporary total knee replacements. Clinical Orthopaedics and Related Research, 317:76–82, 1995. [24] H. Bathis, L. Perlick, M. Tingart, C. Luring, D. Zurakowski, and J. Grifka. Alignment in total knee arthroplasty: A comparison of computer-assisted surgery with the conventional technique. The Journal of Bone and Joint Surgery, 86-B:682–687, 2014. [25] L.E. Bayliss, D. Culliford, A.P. Monk, S. Glyn-Jones, D. Prieto-Alhambra, A. Judge, C. Cooper, A.J. Carr, N.K. Arden, and D.J. Beard. The eﬀect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study. The Lancet, 389:1424–1430, 2017. [26] S. Bell, P. Young, C. Drury, J. Smith, I. Anthony, B. Jones, M. Blyth, and A. McLean. Component rotational alignment in unexplained painful primary total knee arthroplasty. The Knee, 21:272–277, 2014. [27] J. Bellemans, P. D’Hooghe, H. Vandenneucker, G.V. Damme, and J. Victor. Soft tissue balance in total knee arthroplasty: does stress relaxation occur perioperatively? Clinical Orthopaedics and Related Research, 452:49–52, 2006. [28] M.G. Benedetti, F. Catani, T.W. Bilotta, M. Marcacci, E. Mariani, and S. Giannini. Muscle activation pattern and gait biomechanics after total knee replacement. Clinical Biomechanics, 18:871–876, 2003. [29] D.L. Benoit, D.K. Ramsey, M. Lamontagne, L. Xu, P. Wretenberg, and P. Renstrom. In vivo knee kinematics during gait reveals new rotation proﬁles and smaller translations. Clinical orthopaedics and related research, 454:81–88, 2007. [30] M. Berend, M. Ritter, H. Hyldahl, J. Meding, and R. Redelman. Implant migration and failure in total knee arthroplasty is related to body mass index and tibial component size. Journal of Arthroplasty, 23(6):104–109, 2008. [31] M. Berend, M. Ritter, J. Meding, P. Faris, E. Keating, R. Redelman, G. Faris, and K. Davis. The chitranjan ranawat award: Tibial component failure mechanisms in total knee arthroplasty. Clinical Orthopaedics and Related Research, 428:26–34, 2004. [32] M. Berend, M. Ritter, J. Meding, P. Faris, M. Keating, R. Redelman, G. Faris, and K. Davis. Tibial component failure mechanisms in total knee arthroplasty. Clinical Orthopaedics and Related Research, 428:26–34, 2004. [33] R. Berger, H. Rubash, J. Michael, W. Thompson, and S. Lawrence. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clinical Orthopaedics and Related Research, 286:40–47, 1993. [34] R.A. Berger, L.S. Crossett, J.J. Jacobs, and H.E. Rubash. Malrotation causing patellofemoral complications after total knee arthroplasty. Clinical Orthopaedics and Related Research, 356:144–153, 1998. [35] D. Bertolini, G. Nedwin, T. Bringman, D. Smith, and G. Mundy. Stimulation of bone resorption and inhibition of bone formation in vitro by human tumour necrosis factors. Nature, 319:516–518, 1986. [36] K.H. Bloemker, T.M. Guess, L. Maletsky, and K. Dodd. Computational knee ligament modelling using experimentally determined zero-load lengths. Open Biomed Eng J., 6:33–41, 2012. [37] G. Blunn, E. Brach del Preva, L. Costa, J. Fisher, and A. Freeman. Ultra high molecular-weight polyethylene (uhmwpe) in total knee replacement: Fabrication, sterilisation and wear. The Journal of Bone and Joint Surgery, 84:946–949, 2002. [38] M. Bolognesi and A. Hofmann. Computer navigation versus standard instrumentation for tka. Clinical Orthopaedics and Related Research, 440:162–169, 2005. [39] F. Bookstein. Landmark methods for forms without landmarks: morphometrics of group diﬀerences in outline shape. Medical Image Analysis, 1(3):225–243, 1996. [40] F. Bookstein, editor. Morphometric Tools for Landmark Data: Geometry and Biology. Cambridge University Press, 1997. [41] P. Bracco, V. Brunella, M. Luda, E. Brach del Prever, M. Zanetti, and L. Costa. Oxidation behaviour in prosthetic uhmwpe components sterilised with high energy radiation in a low oxygen environment. Journal of Othropaedic Traumatology, 91:3057–3064, 2006. [42] E. Brach del Prever, A. Bistolﬁ, P. Bracco, and L. Costa. Uhmwpe for arthroplasty: Past or future? Journal of Othropaedic Traumatology, 10:1–8, 2009. [43] G.W. Brick and R.D. Scott. The patellofemoral component of total knee arthroplasty. Clinical Orthopaedics and Related Research, 231:163–178, 1988. [44] C.L. Brockett, A. Abdelgaied, T. Haythornthwaite, C. Hardaker, J. Fisher, and L.M. Jennings. The inﬂuence of simulator input conditions on the wear of total knee replacements: An experimental and computational study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 230:429–439, 2016. [45] N. Budhiparama, M. Abdel, and S. Parratte. Icl 19: The importance of surgical technique in the outcome of tkr gap balancing vs measured resection technique for tkr: with speciﬁc reference to ﬁnal outcome, 2015. International Society of Arthroscopy, Knee Surgery and Orthopaedic Sports Medicine. [46] B. Carr and T. Goswami. Knee implants- review of models and biomechanics. Materials and Design, 30:398–413, 2009. [47] Arianna Cerquiglini, Johann Henckel, Harry S. Hothi, Lorenzo Dall’Ava, Paul Shearing, Michael T. Hirschmann, and Alister J. Hart. Computed tomography techniques help understand wear patterns in retrieved total knee arthroplasty. The Journal of Arthroplasty, 33(9):3030 – 3037, 2018. [48] C. Chang and C. Yang. Kinematic navigation in total knee replacement - experience from the ﬁrst 50 cases. Journal of the Formosan Medical Association, 105(6):468–474, 2006. [49] E. Chao, R. Laughman, E. Shneider, and R. Stauﬀer. Normative data of knee joint motion and ground reaction forces in adult level walking. Journal of Biomechanics, 16(3):219 – 233, 1983. [50] S. Chauhan, G. Clark, S. Lloyd, R. Scott, W. Breidahl, and J. Sikorski. Computer-assisted total knee replacement. The Journal of Bone and Joint Surgery, 86-B(6):818–823, 2004. [51] S. Chauhan, R. Scott, W. Breidahl, and R. Beaver. Computer-assisted knee arthroplasty versus a conventional jig-based technique. The Journal of Bone and Joint Surgery, 86-B(3):372–377, 2004. [52] Z. Chen, L. Wang, Y. Liu, J. He, Q. Lian, D. Li, and Z. Jin. Eﬀect of component mal-rotation on knee loading in total knee arthroplasty using multi-body dynamics modeling under a simulated walking gait. Journal of Orthopaedic Research, 33(9):1287–1296, 2015. [53] C. Cheng, C. Huang, J. Liau, and C. Huang. The inﬂuence of surgical malalignment on the contact pressures of ﬁxed and mobile bearing knee prostheses - a biomechanical study. Clinical Biomechanics, 18(3):231–236, 2003. [54] A. Cheung, S.K. Goh, A. Tang, and T.B. Keng. Complications of total knee arthroplasty. Current Orthopaedics, 22(4):274–283, 2008. [55] P. Chin, K. Yang, S. Yeo, and N. Lo. Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. The Journal of Arthroplasty, 20(5):618–626, 2005. [56] P. Choong, M. Dowsey, and J. Stoney. Does accurate anatomical alignment result in better function and quality of life? comparing conventional and computer-assisted total knee arthroplasty. The Journal of Arthroplasty, 24(4):560–569, 2009. [57] J. Collier, D. Sperling, J. Currier, L. Sutula, K. Saum, and M. Mayor. Impact of gamma sterilization on clinical performance of polyehtylene in the knee. The Journal of Arthroplasty, 11(4):377 – 389, 1996. [58] B. Daines and D. Dennis. Gap balancing vs. measured resection technique in total knee arthroplasty. Clinics in Orthopedic Surgery, 6:1 – 8, 2014. [59] F. Daubresse, C. Vajeu, and J. Loquet. Total knee arthroplasty with conventional or navigated technique: Comparison of the learning curves in a community hospital. Acta Orthopaedica Belg, 71:710–713, 2005. [60] A. Demulder, S.V. Suggs, K.M. Zsebo, T. Scarcez, and G.D. Roodman. Eﬀects of stem cell factor on osteoclast-like cell formation in long-term human marrow cultures. Journal of Bone and Mineral Research, 7(11):1337–1344, 1992. [61] D. Dennis, R. Komistek, R. Kim, and A. Sharma. Gap balancing versus measured resection technique for total knee arthroplasty. Clinical Orthopaedics and Related Research, 468:102–107, 2010. [62] J. DesJardins, P. Walker, H. Haider, and J. Perry. The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity. Journal of Biomechanics, 33:1231–1242, 2000. [63] H. Dossett, N. Estrada, G. Swartz, G. LeFevre, and B. Kwasman. A randomised controlled trial of kinematically and mechanically aligned total knee replacements. The Bone and Joint Journal, 96-B(7):907– 913, 2014. [64] M-J. Emami, M-H. Ghahramani, F. Abdinejad, and H. Namazi. Q-angle - an invaluable parameter for evaluation of anterior knee pain. Archives of Iranian Medicine, 10(1):24–26, 2007. [65] K. Ezzet, J. Hermida, C. Colwell Jr, and D. D’Lima. Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator. Clinical Orthopaedics and Related Research, 428:120–124, 2004. [66] K. Ezzet, J. Hermida, N. Steklov, and D. D’Lima. Wear of polyethylene against oxidized zirconium femoral components. The Journal of Arthroplasty, 27(1):116–120, 2012. [67] S. Fantozzi, F. Cantani, A. Ensini, A. Leardini, and S. Giannini. Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo ﬂuoroscopic analysis during activities of daily living. Journal of Orthopaedic Surgery and Research, 24(12):2222–2229, 2006. [68] E. Feng, S. Stulberg, and R. Wixon. Progressive subluxation and polyethylene wear in total knee replacements with ﬂat articular surfaces. Clinical Orthopaedics and Related Research, 299:60–71, 1994. [69] J. Fisher, L. Jennings, A. Galvin, Z. Jin, M. Stone, and E. Ingham. Polyethylene wear in total knees. Clinical Orthopaedics and Related Research, 468:12–18, 2010. [70] J. Fisher, H.M.J McEwen, J. Tipper, A.L. Galvin, J. Ingram, A. Kamali, M.H. Stone, and E. Ingham. Wear, debris, and biologic activity of cross-linked polyethylene in the knee: Beneﬁts and potential concerns. Clinical Orthopaedics and Related Research, 428:114–119, 2004. [71] B. Fregly, C. Marquez-Barrientos, S. Banks, and J. DesJardins. Increased conformity oﬀers diminishing returns for reducing total knee replacement wear. Journal of Biomechanical Engineering, 182:021007– 021007–7, 2010. [72] Benjamin J. Fregly, W.Gregory Sawyer, Melinda K. Harman, and Scott A. Banks. Computational wear prediction of a total knee replacement from in vivo kinematics. Journal of Biomechanics, 38(2):305 – 314, 2005. Knee Mechanics: An Update of Theoretical and Experimental Analyses. [73] T. Fukubayashi, P.A. Torzilli, M.F. Sherman, and R.F. Warren. An in vitro biomechanical evaluation of anterior-posterior motion of the knee. Journal of Bone and Joint Surgery, 64-A:258–264, 1982. [74] J.R. Funk, G.W. Hall, J.R. Crandall, and W.D. Pilkey. Linear and quasi-linear viscoelastic characterization of ankle ligaments. Journal of Biomechanical Engineering, 122(1):15–22, 1999. [75] A. Galvin, L. Kang, J. Tipper, M. Stone, E. Ingham, Z. Jin, and J. Fisher. Wear of crosslinked polyethylene under diﬀerent tribological conditions. Journal of Materials Science: Materials in Medicine, 17:235–243, 2006. [76] A. Galvin, L. Kang, I. Udoﬁa, L. Jennings, H. McEwen, Z. Jin, and J. Fisher. Eﬀect of conformity and contact stress on wear in ﬁxed-bearing total knee prostheses. Journal of Biomechanics, 42:1898–1902, 2009. [77] A. Galvin, J. Tipper, E. Ingham, and J. Fisher. Nanometre size wear debris generated from crosslinked and non-crosslinked ultra high molecular weight polyethylene in artiﬁcial joints. Wear, 259:977–983, 2006. [78] S. Gencur, C. Rimnac, and S. Kurtz. Failure micromechanisms during uniaxial tensile fracture of conventional and highly crosslinked ultra-high molecular weight polyethylenes used in total joint replacements. Biomaterials, 24:3947–3954, 2003. [79] J. Giﬃn, K. Stabile, T. Zantop, T. Vogrin, S. Woo, and C. Harner. Importance of tibial slope for stability of the posterior cruciate ligament-deﬁcient knee. The American Journal of Sports Medicine, 35(9):1443–1449, 2007. [80] J. Giﬃn, T. Vogrin, T. Zantop, T. Vogrin, S. Woo, and C. Harner. Eﬀects of increasing tibial slope on the biomechanics of the knee. The American Journal of Sports Medicine, 32(2):376–382, 2004. [81] A.C. Godest, M. Beaugonin, E. Huang, M. Taylor, and P.J. Gregson. Simulation of a knee joint replacement during a gait cycle using explicit ﬁnite element analysis. Journal of Biomechanics, 35(2):267–275, 2002. [82] A. Gomoll, T. Wanich, and A. Bellare. J-integral fracture toughness and tearing modulus measurement of radiation cross-linked uhmwpe. Journal of Orthopaedic Research, 20:1152–1156, 2002. [83] F.A. Gottschalk, S. Kourosh, M. Stills, B. McClellan, and J. Roberts. Does socket conﬁguration inﬂuence the position of the femur in above-knee amputation? Journal of Prosthestics and Orthotics, 2(1):94, 1989. [84] M. Gowen, D. Wood, E. Ihrie, M. McGuire, and G. Russel. An interleukin 1 like factor stimulates bone resorption in vitro. Nature, 306:378–380, 1983. [85] D. Grecu, I. Antoniac, O. Trante, M. Niculescu, and O. Lupescu. Failure analysis of retrieved polyethylene insert in total knee replacement. Biomaterials, 6:12–15, 2016. [86] F.M. Griﬃn, J.N. Insall, and G.R. Scuderi. Accuracy of soft tissue balancing in total knee arthroplasty. The Journal of Arthroplasty, 15:970–973, 2000. [87] Y. Gu, J. Roth, S. Howell, and M. Hull. How frequently do four methods for mechanically aligning a total knee arthroplasty cause collateral ligament imbalance and change alignment from normal in white patients? The Journal of Bone and Joint Surgery, 96-A(12), 2014. [88] K.A. Gustke, G.J. Golladay, M.W. Roche, G.J. Jerry, L.C. Elson, and C.R. Anderson. Increased satisfaction after total knee replacement using sensor-guided technology. The Bone and Joint Journal, 96-B(10):1333–1338, 2014. [89] R. Haaker, M. Stockheim, M. Kamp, G. Proﬀ, J. Breitenfelder, and A. Ottersbach. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clinical Orthopaedics and Related Research, 433:152–159, 2005. [90] H. Haider, L. Alberts, M. Laurent, T. Johnson, J. Yao, L. Gilbertson, P. Walker, J. Neﬀ, and K. Garvin. Comparison between force-controlled and displacement-controlled in-vitro wear testing on a widely used tkr implant. In Transactions of the annual meeting - orthopaedic research society, pages 1007–1007, 2002. [91] H. Haider, T. Sekundiak, and K. Garvin. Analysis and recommendations for the optimum spring conﬁgurations for soft tissue restraint in force-control knee simulator testing. 48th Annual Meeting of Orthopaedic Research Society, 2002. [92] H. Haider, P. Walker, J. DesJardins, and G. Blunn. Eﬀects of patient and surgical alignment variables on kinematics in tkr simulation under force-control. Journal of ASTM International, 3(10):3–16, 2006. [93] Hani Haider. Chapter 26 - tribological assessment of uhmwpe in the knee. In Steven M. Kurtz, editor, UHMWPE Biomaterials Handbook (Second Edition), pages 381 – 408. Academic Press, Boston, second edition edition, 2009. [94] J. Halloran, A. Petrella, and P. Rullkoetter. Explicit ﬁnite element modeling of total knee replacement mechanics. Journal of Biomechanics, 38:323–331, 2005. [95] M. Harman, J. DesJardins, S. Banks, L. Benson, M. Laberge, and W. Hodge. Damage patterns on polyethylene inserts after retrieval and after wear simulation. 47th Annual Meeting, Orthopaedic Research Society. Implant Wear., 2001. [96] P. Harvie, K. Sloan, and R. Beaver. Computer navigation vs conventional total knee arthroplasty; ﬁveyear functional results of a prospective randomized trial. The Journal of Arthroplasty, 27(5):667–672, 2012. [97] W. Healy, R. Lorio, and M. Lemos. Athletic activity after joint replacement. The American Journal of Sports Medicine, 3(29):377–388, 2001. [98] P.F. Hill, V. Vedi, A. Williams, H. Iwaki, V. Pinkserova, and M.A.R. Freeman. Tibiofemoral movement 2: the loaded and unloaded living knee studied by mri. The Journal of Bone and Joint Surgery, 82(B):1196– 1198, 2000. [99] S. Howell, S. Papadopoulos, K. Kuznik, and M. Hull. Accurate alignment and high function after kinematically aligned tka performed with generic instruments. Knee Surgery, Sports Traumatology, Arthroscopy, 0942-2056, 2013. [100] H. Hsu, A. Garg, P. Walker, M. Spector, and F. Ewald. Eﬀect of knee component alignment on tibial load distribution with clinical correlation. Clinical Orthopaedics and Related Research, 248:135–144, 1989. [101] T. Huang, L. Kuo, K. Peng, M. Lee, and R. Hsu. Computer tomography evaluation in total knee arthroplasty: Computer-assisted navigation versus conventional instrumentation in patients with advanced valgus arthritic knees. The Journal of Arthroplasty, 29:2363–2368, 2014. [102] D.E Hurwitz, A.B Ryals, J.P Case, J.A Block, and T.P Andriacchi. The knee adduction moment during gait in subjects with knee osteoarthritis is more closely correlated with static alignment than radiographic disease severity, toe out angle and pain. Journal of Orthopaedic Research, 20(1):101 – 107, 2002. [103] E. Ingham and J. Fisher. Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 214(1):21–37, 2000. [104] M. Ishikawa, S. Kuriyama, H. Ito, M. Furu, S. Nakamura, and S. Matsuda. Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: A case study on a single implant design. The Knee, 22:206–212, 2015. [105] H. Iwaki, V. Pinskerova, and M.A.R. Freeman. Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaverknee. The Journal of Bone and Joint Surgery, 82(B):1189–1195, 2000. [106] Faezeh Jahani. Modelling of dynamic edge loading in total hip replacements with ceramic on plyethylene bearings. PhD Thesis, 2017. [107] L. Jennings, M. Al-Hajjar, C. Brockett, S. Williams, J. Tipper, E. Ingham, and J. Fisher. Enhancing the safety and reliability of joint replacement implants. Orthopaedics and Trauma, 26(4):246 – 252, 2012. [108] Z. Jin, M. Stone, E. Ingham, and J. Fisher. Biotribology. Current Orthopaedics, 20:32 – 40, 2006. [109] T. Johnson, M. Laurent, J. Yao, and L. Gilbertson. The eﬀect of displacement control input parameters on tibiofemoral prosthetic knee wear. Wear, 250:222 – 226, 2001. [110] H. Jojima, L. Whiteside, and K. Ogata. Eﬀect of tibial slope or posterior cruciate ligament release on knee kinematics. Clinical Orthopaedics and Related Research, 426:194–198, 2004. [111] M. Jones and D. Scott, editors. Industrial Tribology: The Practical Aspects of Friction, Lubrication and Wear. North Holland [Imprint], 1983. [112] Cynthia A. Kahlenberg, Benedict U. Nwachukwu, Alexander S. McLawhorn, Michael B. Cross, Charles N. Cornell, and Douglas E. Padgett. Patient satisfaction after total knee replacement: A systematic review. HSS Journal ˆ A®, 14(2):192–201, Jul 2018. [113] A. Kanamori, J. Zeminski, T.W. Rudy, G. Li, F.H. Fu, and S.L-Y. Woo. The eﬀect of axial tibial torque on the function of the anterior cruciate ligament: a biomechanical study of a simulated pivot shift test. Arthroscopy: The Journal of Arthroscopic and Related Surgery, 18:394–398, 2002. [114] Kyoung-Tak Kang, Yong-Gon Koh, Juhyun Son, Oh-Ryong Kwon, Jun-Sang Lee, and Sae-Kwang Kwon. Inﬂuence of increased posterior tibial slope in total knee arthroplasty on knee joint biomechanics: A computational simulation study. The Journal of Arthroplasty, 2017. [115] K. Kato and K. Adachi, editors. Modern Tribology Handbook, Chapter 7. Wear Mechanisms. CRC Press, 2001. [116] L. Knight, S. Pal, J. Coleman, F. Bronson, H. Haider, D. Levine, M. Taylor, and P. Rullkoetter. Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading. Journal of Biomechanics, 40:1550–1558, 2006. [117] R. Komistek, D. Dennis, and M. Mahfouz. In vivo ﬂuoroscopic analysis of the normal human knee. Clinical Orthopaedics and Related Research, 410:69–81, 2003. [118] D. Kopeliovich. Mechanisms of wear. Accessed 28.01.2016. [119] S. Kurtz, editor. The UHMWPE Handbook. Elsevier, 2004. [120] S. Kurtz, editor. UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyetheylene in Total Joint Replacement and Medical Devices. Elsevier, 2016. [121] S. Kurtz, C. Jewetta, J. Bergstroma, J. Fouldsa, and A. Edidin. Miniature specimen shear punch test for uhmwpe used in total joint replacements. Journal of Biomaterials, 23:1907–1919, 2002. [122] S. Kurtz, K. Ong, E. Lau, F. Mowat, and M. Halpern. Projections of primary and revision hip and knee arthroplasty in the united states from 2005 to 2030. JBJS, 89:780–785, 2007. [123] M. Lafortune, P. Cavanagh, H. Sommer, and A. Kalenak. Three-dimensional kinematics of the human knee during walking. Journal of Biomechanics, 25(4):347 – 357, 1992. [124] Yong Seuk Lee, Stephen M. Howell, Ye-Yeon Won, O-Sung Lee, Seung Hoon Lee, Hamed Vahedi, and Seow Hui Teo. Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy, 25(11):3467–3479, Nov 2017. [125] G. Lewis. Properties of crosslinked ultra-high-molecular-weight polyethylene. Biomaterials, 22:371–401, 2001. [126] J. Liau, C. Cheng, C. Huang, and W. Lo. The eﬀect of malalignment on stresses in polyethylene component of total knee prostheses - a ﬁnite element analysis. Clinical Biomechanics, 17:140–146, 2002. [127] L. Longstaﬀ, K. Sloan, N. Stamp, M. Scaddan, and R. Beaver. Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. The Journal of Arthroplasty, 24(4):570–578, 2009. [128] J. Lorenzo, S. Sousa, J. Foriseca, J. Hock, and E. Medlock. Colony-stimulating factors regulate the development of multinicleated osteoclasts from recently replicated cells in vitro. Journal of Clinical Investigation, 80:160–164, 1987. [129] S. Maruyuna, S. Yoshiya, N. Matsui, R. Kuroda, and M. Kurosaka. Functional comparison of posterior cruciate-retaining versus posterior stabilized total knee arthroplasty. Journal of Arthroplasty, 19:349–353, 2004. [130] J. Mason, T. Fehring, R. Estok, D. Banel, and K. Fahrbach. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. The Journal of Arthroplasty, 22:1097–1106, 2007. [131] P. Massin and A. Gournay. Optimization of the posterior condylar oﬀset, tibial slope, and condylar roll-back in total knee arthroplasty. The Journal of Arthroplasty, 21(6):889–896, 2006. [132] H. McEwen, P. Barnett, C. Bell, R. Farrar, D. Auger, M. Stone, and J. Fisher. The inﬂuence of design, materials and kinematics on the in vitro wear of total knee replacements. The Journal of Biomechanics, 38:357–365, 2005. [133] Peter J. McNair, Mark G. Boocock, Nicholas D. Dominick, Richard J. Kelly, Bill J. Farrington, and Simon W. Young. A comparison of walking gait following mechanical and kinematic alignment in total knee joint replacement. The Journal of Arthroplasty, 33(2):560 – 564, 2018. [134] S.P. Mell, S. Fullam, M.A. Wimmer, and H.J. Lundberg. Sensitivity of total knee replacement wear to tibial component malrotation. In Transactions of the annual meeting - orthopaedic research society, 2009. [135] S.P. Mell, M.A. Wimmer, J.J. Jacobs, and H.J. Lundberg. Total knee replacement wear is most sensitive to transverse plane alignment - a parametric ﬁnite element study. In Transactions of the annual meeting - orthopaedic research society, 2009. [136] R.L. Merkow, M. Soudry, and J.N. Insall. Patellar dislocation following total knee replacement. The Journal of Bone and Joint Surgery, American Volume, 67(9):1321–1327, 1985. [137] H. Mizu-uchi, S. Matsuda, H. Miura, K. Okazaki, Y. Alasaki, and Y. Iwamoto. The evaluation of postoperative alignment in total knee replacement using a ct-based navigation system. The Journal of Bone and Joint Surgery, 90-B(8):1025–1031, 2008. [138] Y. Mizuno, M. Kumagai, S.M. Mattessich, J.J. Elias, N. Ramrattan, A.J. Cosgarea, and E.Y.S. Chao. Qangle inﬂuences tibiofemoral and patellofemoral kinematics. Journal of Orthopaedic Research, 19(5):834– 840, 2001. [139] Matthew F. Moran, Saﬁa Bhimji, Joseph Racanelli, and Stephen J. Piazza. Computational assessment of constraint in total knee replacement. Journal of Biomechanics, 41(9):2013 – 2020, 2008. [140] J. Moreland. Mechanisms of failure in total knee arthroplasty. Clinical Orthopaedics and Related Research, 226:49–64, 1988. [141] J. Morrison. The mechanics of the knee joint in relation to normal walking. Journal of Biomechanics, 3:51–61, 1970. [142] E. Most, S. Zayontz, G. Li, E. Otterberg, K. Sabbag, and H.E. Rubash. Femoral rollback after cruciateretaining and stabilizing total knee arthroplasty. Clinical Orthopaedics and Related Research, 410:101– 113, 2003. [143] A. Mouttet and V. Sourdet. Europ total knee prosthesis with or without posterior cruciate ligament retention? comparative study at mid-term follow-up. Orthopaedics and Traumatology: Surgery and Research, 100:895–900, 2014. [144] V. Musahl, K.M. Bell, A.G. Tsai, R.S. Costic, R. Allaire, T. Zantop, J.J. Irrgang, and F.H. Fu. Development of a simple device for measurement of rotational knee laxity. Knee Surgery, Sports Traumatology, Arthroscopy, 15:1009–1012, 2007. [145] Y. Nagano, K. Naito, Y. Saho, S. Torii, T. Ogata, K. Nakazawa, M. Akai, and T. Fukubayashi. Association between in vivo knee kinematics during gait and the severity of knee osetoarthritis. The Knee, 19:628–632, 2012. [146] S. Nakagawa, Y. Kadoya, S. Todo, A. Kobayashi, H. Sakamoto, M.A.R. Freeman, and Y. Yamano. Tibiofemoral movement 3: full ﬂexion in the living knee studied by mri. The Journal of Bone and Joint Surgery, 82(B):1199–1200, 2000. [147] J. Nevelos, E. Ingham, C. Doyle, A. Nevelos, and J. Fisher. The inﬂuence of acetabular cup angle on the wear of ”biolox forte”alumina ceramic bearing couples in a hip joint simulator. Journal of Materials Science: Materials in Medicine, 12:141 – 144, 2001. [148] D. Nicoll and D. Rowley. International rotational error of the tibial component is a major cause of pain after total knee replacement. The Journal of Bone and Joint Surgery, 92-B:1238–1244, 2010. [149] NJR. National joint registry for england, wales, northern ireland and the isle of man: 13th annual report. 2006. [150] NJR. National joint registry for england, wales, northern ireland and the isle of man: 15th annual report. 2018. [151] T.L. Norman, J. Hutchison, M.R. Gardner, and J.D. Blaha. Knee loading due to varus and external rotation in gait supports medial compartment wear in total knee arthroplasty. The Scientiﬁc Pages of Orthopedics and Rheumatism, 1(1):8–18, 2017. [152] W. Norman Scott, editor. Insall and Scott Surgery of the Knee. Elsevier, 5 edition, 2012. [153] W. Norman Scott, editor. Insall and Scott Surgery of the Knee, Volume II. Elsevier, 6 edition, 2018. [154] O.D. Noyes, F.R. abd Schipplein, T.P. Andriacchi, S.R. Saddemi, and M. Welse. The anterior cruciate ligament-deﬁcient knee with varus alignment: An analysis of gait adaptations and dynamic joint loadings. The American Journal of Sports Medicine, 20(6):707–716, 1992. [155] Knee Restoration Center of Indiana. Anatomy. Accessed 28.01.19. [156] C. Olcott and R. Scott. Femoral component rotation during total knee arthroplasty. Clinical Orthopaedics and Related Research, 367:39–42, 1999. [157] M.W. Pagnano, A.D. Hanssen, D.G. Lewallen, and M.J. Stuart. Flexion instability after primary posterior cruciate retaining total knee arthroplasty. Clinical Orthopaedics and Related Research, 356:39–46, 1998. [158] J. Parizi, R.M. Nunley, K.R. Berend, A.V. Lombardi Jr, E.L. Ruth, and J.C. Clohisy. High level of residual symptoms in young patients after total knee arthroplasty. Clinical Orthopaedics and Related Research, 472(1):133–137, 2014. [159] S. Parratte and M.W. Pagnano. Eﬀect of postoperative mechanical axis alignment on the ﬁfteen year survival of modern cemented total knee replacements. The Journal of Bone and Joint Surgery, 92(12):2143– 2149, 2010. [160] E. Pena, B. Calvo, M.A. Martinez, and M. Doblare. A three-dimensional ﬁnite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint. Journal of Biomechanics, 39(9):1686 – 1701, 2006. [161] D. Pereira, F. Jaﬀe, and C. Ortiguera. Posterior cruciate ligament-sparing versus posterior cruciate ligament-sacriﬁcing arthroplasty. Journal of Arthroplasty, 13:138–144, 1998. [162] A. Perillo-Marcone and M. Taylor. Eﬀect of varus/valgus malalignment on bone strains in the proximal tibia after tkr: An explicit ﬁnite element study. Journal of Biomechanical Engineering, 129(1):1–11, 2006. [163] S. Pickering and D. Armstrong. Alignment in total knee replacement. The Journal of Bone and Joint Surgery, 468, 2012. URL http://www.boneandjoint.org.uk/content/focus/alignment-total-knee-replacement Accessed 27.10.2015. [164] C. Plaskos, A. Hodgson, K. Inkpen, and R. McGraw. Bone cutting errors in total knee arthroplasty. The Journal of Arthroplasty, 17(6):698–705, 2002. [165] Tobias Pohlen. Fourier descriptor. Accessed 19.12.17. [166] L. Pruitt. Deformation, yielding, fracture and fatigue behaviour of conventional and highly cross-linked ultra high molecular weight polyethylene. Biomaterials, 26:905–915, 2005. [167] S. Puloski, R. McCalden, S. MacDonald, C. Rorabeck, and R. Bourne. Tibial post wear in posterior stabilized total knee arthroplasty. Journal of Bone and Joint Surgery, 83:390–397, 2001. [168] E. Rabinowicz. The least wear. Wear, 100:533 – 541, 1984. [169] C.S. Ranawat. The patellofemoral joint in total condylar knee arthroplasty. pros and cons based on ﬁveto ten-year follow-up observations. Clinical Orthopaedics and Related Research, 205:93–99, 1986. [170] Amin S., N. Luepongsak, C.A. McGibbon, M.P. LaValley, D.E. Krebs, and D.T. Felson. Knee adduction moment and development of chronic knee pain in elders. Arthritis and Rheumatism (Arthritis care and research), 51(3):371–376, 2004. [171] T. Sando, R. McCalden, R. Bourne, S. MacDonald, and L. Somerville. Ten-year results comparing posterior cruciate-retaining versus posterior cruciate-substituting total knee arthroplasty. Journal of Arthroplasty, 30:210–215, 2015. [172] W. Schroer, K. Berend, A. Lombardi, C. Barnes, M. Bolognesi, M. Berend, M. Ritter, and R. Nunley. Why are total knees failing today? etiology of total knee revision in 2010 and 2011. The Journal of Arthroplasty, 28:116–119, 2013. [173] T. Schwenke, C. Kaddick, E. Schneider, and M. Wimmer. Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine, 219(6):457 – 64, 2005. [174] T. Schwenke, D. Orozco, E. Schneider, and M. Wimmer. Diﬀerences in wear between load and displacement control tested total knee replacements. Wear, 267(5-8):757 – 762, 2009. [175] G.R. Scuderi and J.N Insall. Total knee arthroplasty. current clinical perspectives. Clinical Orthopaedics and Related Research, 276:26–32, 1992. [176] SharcNet. Choosing between linear and higher order elements. Accessed 14.11.18. [177] SharcNet. Degenerated shape elements. Accessed 14.11.18. [178] P. Sharkey, W. Hozack, R. Rothman, S. Shastri, and S. Jacoby. Why are total knee arthroplasties failing today? Clinical Orthopaedics and Related Research, 404:7–13, 2002. [179] K. Shelburne, H. Kim, W. Sterett, and M. Pandy. Eﬀect of posterior tibial slope on knee biomechanics during functional activity. Journal of Orthopaedic Research, 29:223–231, 2011. [180] R. Shenoy, P.S. Pastides, and D. Nathwani. (iii) biomechanics of the knee and tkr. Orthopaedics and Trauma, 27(6):364 – 371, 2013. [181] Omer Slevin, Anna Hirschmann, Filippo F. Schiapparelli, Felix Amsler, Rolf W. Huegli, and Michael T. Hirschmann. Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3d-ct. Knee Surgery, Sports Traumatology, Arthroscopy, Oct 2017. [182] C.R Smith, M.F. Vifnos, R.L. Lenhart, J. Kaiser, and D.G. Thelen. The inﬂuence of component alignment and ligament properties on tibiofemoral contact forces in total knee replacement. Journal of Biomechanical Engineering, 138(2), 2016. [183] H.J. Sommer. Polygeom.m. Accessed 29.01.18. [184] A. Srivastava, G. Lee, N. Steklov, C. Colwell Jr., K. Ezzet, and D. D’Lima. Eﬀect of tibial component varus on wear in total knee arthroplasty. The Knee, 19(5):560–563, 2012. [185] British Standard. Geometric product speciﬁcations (gps) - surface texture: Proﬁle method - nominal characteristics of contact (stylus) instruments. ISO, 3274, 1998. [186] British Standard. Implants for Surgery - Wear of Total Knee-joint Prostheses, Part 1: Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test, 2009. 14243-1. [187] British Standard. Implants for Surgery - Wear of Total Knee-joint Prostheses, Part 2: Methods of Measurement, 2009. 14243-2. [188] British Standard. Implants for Surgery - Wear of Total Knee-joint Prostheses, Part 3: Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test, 2014. 14243-3. [189] D-S. Suh, K-T. Kang, J. Son, O-R. Kwon, C. Baek, and Y-G. Koh. Computational study on the eﬀect of malalignment of the tibial component on the biomechanics of total knee arthroplasty. Bone and Joint Research, 6(11), 2017. [190] M. Sundfelt, L. Carlsson, C. Johansson, P. Thomsen, and C. Gretzer. Asceptic loosening, not only a question of wear. Acta Orthopaedica, 77:177–197, 2006. [191] M. Tanzer. Posterior stabilized versus cruciate retaining total knee arthroplasty. Journal of Arthroplasty, 17:813–819, 1970. [192] P. Trent and P. Walker. Wear and conformity in total knee replacement. Wear, 36:175–187, 1976. [193] K. Valkering, S. Breugem, M. van den Bekerom, W. Tuinebreijer, and R. van Geenen. Eﬀect of rotational alignment on outcome of total knee arthroplasty. Acta Orthopaedica, 86(4):432–439, 2015. [194] M. Van Houtem, R. Clough, A. Khan, M. Harrison, and G. Blunn. Validation of the soft tissue restraints in a force-controlled knee simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 220(3):449–456, 2006. [195] Pieter-Jan T.K. Vandekerckhove, Matthew G. Teeter, Douglas D.R. Naudie, James L. Howard, Steven J. MacDonald, and Brent A. Lanting. The impact of coronal plane alignment on polyethylene wear and damage in total knee arthroplasty: A retrieval study. The Journal of Arthroplasty, 32(6):2012 – 2016, 2017. [196] P. Walker and H. Haider. Characterizing the motion of total knee replacements in laboratory tests. Clinical Orthopaedics and Related Research, 410:54–68, 2003. [197] P.S. Walker, G.W. Blunn, D.R. Broome, J. Perry, A. Watkins, S. Sathasivam, M.E. Dewar, and J.P. Paul. A knee simulating machine for performance evaluation of total knee replacements. Journal of Biomechanics, 30:83–89, 1997. [198] P.S. Warren, T.K. Olanlokun, A.G. Cobb, P.S. Walker, and B. Iverson. Laxity and function in knee replacements: A comparative study of three prosthetic designs. Clinical Orthopaedics and Related Research, 305:200–228, 1994. [199] R.C. Wasielewski, D.D. Galat, and R.D. Komistek. Correlation of compartment pressure data from an intraoperative sensing device with postoperative ﬂuoroscopic kinematic results in tka patients. Journal of Biomechanics, 38(2):333–339, 2005. [200] G. Waslewski, B. Marson, and J. Benjamin. Early, incapacitating instability of posterior cruciate ligament-retaining total knee arthroplasty. Journal of Arthroplasty, 13:763–767, 1998. [201] F. Werner, D. Ayers, L. Maletsky, and P. Rullkoetter. The eﬀect of varus/valgus malalignment on load distribution in total knee replacements. Journal of Biomechanics, 38:349–355, 2005. [202] S. White, R. Paxson, M. Tanner, and L. Whiteside. Eﬀects of sterilization on wear in total knee arthroplasty. Clinical Orthopaedics and Related Research, (331):164 – 171, 1996. [203] R. Willing and I. Kim. Three dimensional shape optimization of total knee replacements for reduced wear. Journal of Structural and Multidisciplinary Optimization, Medical and Bioengineering Application, 38:405–414, 2008. [204] R. Willing and I.Y. Kim. A holistic numerical model to predict strain hardening and damage of uhmwpe under multiple total knee replacement kinematics and experimental validation. Journal of Biomechanics, 42(15):2520–2527, 2009. [205] Huseyin S. Yercan, Tarik Ait Si Selmi, Tahir S. Sugun, and Philippe Neyret. Tibiofemoral instability in primary total knee replacement: A review, part 1: Basic principles and classiﬁcation. The Knee, 12(4):257–266, 2005. [206] J. Yim, E. Song, M. Khan, Z. Sun, and J. Seon. A comparison of classical and anatomical total knee alignment methods in robotic total knee arthroplasty. The Journal of Arthroplasty, 28:932–937, 2013. [207] D. Zhao, H. Sakoda, W. Sawyer, and B. Fregly. Predicting knee replacement damage in a simulator machine using a computational model with a consistent wear factor. Journal of Biomechanical Engineering, 130, 2008. [208] M. Zihlmann, A. Stacoﬀ, J. Romero, I. Quervain, and E. Stussi. Biomechanical background and clinical observations of rotational malalignment in tka: Literature review and consequences. Clinical Biomechanics, 20:661–668, 2005. [209] M. Zumstein, L. Frauchiger, D. Wyss, R. Hess, and P. Ballmer. Is restricted femoral navigation suﬃcient for accuracy of total knee arthroplasty? Clinical Orthopaedics and Related Research, 451:80–86, 2006."],"dcterms:accessrights":["public"],"dc:title":["The Eﬀect of Surgical Alignment and Soft Tissue Constraints on the Kinematics, Contact Pressure and Wear of a Total Knee Replacement"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:33:25Z"}