{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:25176"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:25176","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Assessment of the potential and risk of fractionated stereotactic radiosurgery for brain lesions using the Gamma Knife system.","abstract":"Introduction: The Gamma Knife (GK) was originally introduced as a radiotherapy unit for solid brain lesions. The original skull-attached G-frame enabled submillimetre accuracy but allowed only single-fraction treatments, thus limiting to small lesion treatments. To enable fractionated Stereotactic Radiosurgery, the GK Perfexion model (with eXtend) was introduced leading to new questions: • What is the repositioning system accuracy? • What effect have positional uncertainties for the target; and for normal tissue (NT) and Organs at risk (OAR)? • How can positional uncertainties be handled? Material and Method: eXtend uncertainty was investigated using trigger levels of the vacuum-surveilled patient positioning mouthpiece, measured for ten patients’ dental models mounted on a 0.05mm-accuracy computer-controlled positioner. The dosimetric effect of these displacements in a single fraction was evaluated by calculating minimum dose, coverage and conformity-index changes for displacements of 0 to 4mm.The impact of positional displacements for 3 and 5 fraction treatments was evaluated for targets and organs-at-risk (OaR) by calculating total doses with simulated displacements of 0-4mm in combinations of X, Y, and Z directions for nine patients (in total almost 300 sumPlans). All plans were prescribed to the 50% isodose. Effects were calculated in physical dose and in biological effective dose (BED). Finally, from this a novel approach to minimize effects of displacement was proposed and feasibility-tested for 5-fraction plans. Instead of applying margins to cover potential uncertainties, a correction is applied in the last two fractions only after any observed systematic uncertainty is quantified in the first three fractions. 100 displacement scenarios were tested, comparing for each the dose volume histogram (DVH) and dose profiles and the total dose with and without the correction procedure. Results: Mean positional uncertainty with a clinical vacuum setting was 0.15mm (SD ±0.05mm, range 0.05-0.29mm) and 0.33° (SD ±0.15°, 0.05°-1.0°). The most critical parameter in the dose distribution is minimum dose D99%. In the evaluated scenarios D99% fell by 2% for a displacement of 0.5mm and 16% with 2mm in X or Y direction and >20% in Z direction, dependent on arrangement. Moving to hypofractionation increases the BED inside the target and reduces it outside, i.e. the dose gradient is increased at the 50% (prescription) isodose. Displacement in opposing directions is predominantly random, which reduces the dose gradient but does not introduce an underdosage to the target for displacements of up to 2 mm. At the same time the BED to OAR is increased but remains below single fraction dose. Feasibility testing the proposed correction method showed a significant improvement of the total BED indicating the method’s potential. Discussion: Positional uncertainty is generally low, better than 0.5mm for Perfexion whilst the later GK version, Icon. starts treatment with minimal uncertainties following an initial Cone Beam CT (CBCT). However, for both treatment units, target movement during treatment is possible and may be up to 2mm. The most critical aspect is underdosage of the target. Prescribing the dose to 50% reduces random uncertainty effects and ensures BED is at an optimal value (gradient) to avoid underdosage and protect OAR. A novel strategy is proposed and feasibility-tested to correct positional uncertainties, showing improved dose distribution in the scenarios tested. However, this test was for static displacements only. GK Icon corrects any positional displacement observed at the initial CBCT, so the correction method would only be needed when the system identifies further movement. For practical clinical use, further investigation is needed.","abstract_html":"Introduction: The Gamma Knife (GK) was originally introduced as a radiotherapy unit for solid brain lesions. The original skull-attached G-frame enabled submillimetre accuracy but allowed only single-fraction treatments, thus limiting to small lesion treatments. To enable fractionated Stereotactic Radiosurgery, the GK Perfexion model (with eXtend) was introduced leading to new questions: • What is the repositioning system accuracy? • What effect have positional uncertainties for the target; and for normal tissue (NT) and Organs at risk (OAR)? • How can positional uncertainties be handled? Material and Method: eXtend uncertainty was investigated using trigger levels of the vacuum-surveilled patient positioning mouthpiece, measured for ten patients’ dental models mounted on a 0.05mm-accuracy computer-controlled positioner. The dosimetric effect of these displacements in a single fraction was evaluated by calculating minimum dose, coverage and conformity-index changes for displacements of 0 to 4mm.The impact of positional displacements for 3 and 5 fraction treatments was evaluated for targets and organs-at-risk (OaR) by calculating total doses with simulated displacements of 0-4mm in combinations of X, Y, and Z directions for nine patients (in total almost 300 sumPlans). All plans were prescribed to the 50% isodose. Effects were calculated in physical dose and in biological effective dose (BED). Finally, from this a novel approach to minimize effects of displacement was proposed and feasibility-tested for 5-fraction plans. Instead of applying margins to cover potential uncertainties, a correction is applied in the last two fractions only after any observed systematic uncertainty is quantified in the first three fractions. 100 displacement scenarios were tested, comparing for each the dose volume histogram (DVH) and dose profiles and the total dose with and without the correction procedure. Results: Mean positional uncertainty with a clinical vacuum setting was 0.15mm (SD ±0.05mm, range 0.05-0.29mm) and 0.33° (SD ±0.15°, 0.05°-1.0°). The most critical parameter in the dose distribution is minimum dose D99%. In the evaluated scenarios D99% fell by 2% for a displacement of 0.5mm and 16% with 2mm in X or Y direction and &gt;20% in Z direction, dependent on arrangement. Moving to hypofractionation increases the BED inside the target and reduces it outside, i.e. the dose gradient is increased at the 50% (prescription) isodose. Displacement in opposing directions is predominantly random, which reduces the dose gradient but does not introduce an underdosage to the target for displacements of up to 2 mm. At the same time the BED to OAR is increased but remains below single fraction dose. Feasibility testing the proposed correction method showed a significant improvement of the total BED indicating the method’s potential. Discussion: Positional uncertainty is generally low, better than 0.5mm for Perfexion whilst the later GK version, Icon. starts treatment with minimal uncertainties following an initial Cone Beam CT (CBCT). However, for both treatment units, target movement during treatment is possible and may be up to 2mm. The most critical aspect is underdosage of the target. Prescribing the dose to 50% reduces random uncertainty effects and ensures BED is at an optimal value (gradient) to avoid underdosage and protect OAR. A novel strategy is proposed and feasibility-tested to correct positional uncertainties, showing improved dose distribution in the scenarios tested. However, this test was for static displacements only. GK Icon corrects any positional displacement observed at the initial CBCT, so the correction method would only be needed when the system identifies further movement. For practical clinical use, further investigation is needed.","abstract_has_math":false,"creators":["Reiner, Beatrice"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Buckley, David","Thwaites, David"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-12","date_published":"2018-12","updated_at":"2026-11-18T22:34:51Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.789407"],"render_values":[{"text":"uk.bl.ethos.789407","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/25176/1/Reiner_B_School_of_Medicine_PhD_2018.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A25176","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Buckley, David","Thwaites, David"]},{"key":"dc:creator","label":"Author","values":["Reiner, Beatrice"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-12"]},{"key":"dc:date.issued","label":"Date","values":["2018-12"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Academic Unit of Medical Physics (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/25176/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. Reiner, B., et al., Quantifying the trigger level of the vacuum surveillance system of the Gamma-Knife eXtend™ positioning system and evaluating the potential impact on dose delivery. Journal of Radiosurgery & SBRT, 2016. 4(1): p. 31-42. 2. Reiner, B., et al., Quantifying the effects of positional uncertainties and estimating margins for Gamma-Knife® fractionated radiosurgery of large brain metastases. Journal of Radiosurgery & SBRT 2017. 4(4): p. 275-287. 3. Lippitz, B., et al., Stereotactic radiosurgery in the treatment of brain metastases: The current evidence. Cancer Treatment Reviews, 2013. 40(1): p. 48-59. 4. Andrews, D.W., et al., Whole brain radiation therapy with or without stereotactic radiosurgery boost for patients with one to three brain metastases: phase III results of the RTOG 9508 randomised trial. The Lancet, 2004. 363(9422): p. 1665. 5. UK, C.r. Brain, other CNS and intracranial tumours Key Facts. 2014-2016 30/09/19 [cited 2019 15 Sept.]; Available from: http://www.cancerresearchuk.org/cancer-info/cancerstats/keyfacts/brain-cancer/. 6. Baumert, B.G., et al., Fractionated stereotactic radiotherapy boost after post-operative radiotherapy in patients with high-grade gliomas. Radiotherapy and Oncology, 2003. 67(2): p. 183-190. 7. Andrews, D.W., et al., Whole brain radiation therapy with or without stereotactic radiosurgery boost for patients with one to three brain metastases: phase III results of the RTOG 9508 randomised trial. The Lancet, 2004. 363(9422): p. 1665-1672. 8. Choi, C.Y.H., et al., Stereotactic Radiosurgery of the Postoperative Resection Cavity for Brain Metastases: Prospective Evaluation of Target Margin on Tumor Control. International Journal of Radiation Oncology*Biology*Physics, 2012. 84(2): p. 336-342. 9. Asher, A.L., et al., A New Treatment Paradigm: Neoadjuvant Radiosurgery Before Surgical Resection of Brain Metastases With Analysis of Local Tumor Recurrence. International Journal of Radiation Oncology*Biology*Physics, 2014. 88(4): p. 899-906. 10. U. M. Lütolf and U. Ulmer, clinical practice. University Hospital Zurich, Switzerland, 1995-2000. personal communication. 11. Balducci, M., et al., Radiosurgery or Fractionated Stereotactic Radiotherapy plus Whole-brain Radioherapy in Brain Oligometastases: A Long-term Analysis. Anticancer Res, 2015. 35(5): p. 3055-9. 12. Barani, I.J. and D.A. Larson, Radiation therapy of glioblastoma. Cancer Treat Res, 2015. 163: p. 49-73. 13. Chang, E.L., et al., Neurocognition in patients with brain metastases treated with radiosurgery or radiosurgery plus whole-brain irradiation: a randomised controlled trial. The Lancet Oncology, 2009. 10(11): p. 1037-1044. 14. Choi, C.Y.H., et al., What Is the Optimal Treatment of Large Brain Metastases? An Argument for a Multidisciplinary Approach. Int J Radiat Oncol Biol Phys, 2012. 84(3): p. 688-693. 15. Ernst-Stecken, A., et al., Phase II trial of hypofractionated stereotactic radiotherapy for brain metastases: Results and toxicity. Radiother. Oncol., 2006. 81(1): p. 18-24. 16. Mehta, M.P., et al., The American Society for Therapeutic Radiology and Oncology (ASTRO) evidence-based review of the role of radiosurgery for brain metastases. Int J Radiat Oncol Biol Phys, 2005. 63(1): p. 37-46. 17. Patchell, R.A., et al., Postoperative radiotherapy in the treatment of single metastases to the brain: a randomized trial. Jama, 1998. 280(17): p. 1485-9. 18. Patchell, R.A., The management of brain metastases. Cancer Treat Rev, 2003. 29(6): p. 533-40. 19. Skeie, B.S., et al., Gamma Knife Surgery versus Reoperation for Recurrent Glioblastoma Multiforme. World Neurosurgery, 2012. 78(6): p. 658-669. 20. Hughes, R.T., et al., Initial SRS for Patients With 5 to 15 Brain Metastases: Results of a Multi-Institutional Experience. International Journal of Radiation Oncology*Biology*Physics, 2019. 104(5): p. 1091-1098. 21. Dirven, L., et al., Impact of Radiation Target Volume on Health-Related Quality of Life in Patients With Low-Grade Glioma in the 2-Year Period Post Treatment: A Secondary Analysis of the EORTC 22033-26033. International Journal of Radiation Oncology*Biology*Physics, 2019. 104(1): p. 90-100. 22. Fan, X.-W., et al., Simultaneously avoiding the hippocampus and hypothalamic-pituitary axis during whole brain radiotherapy: A planning study. Medical Dosimetry, 2019. 44(2): p. 130-135. 23. Andreas, J.J.M. and V. Kundapur, Hippocampus Avoidance Whole-brain Radiation Therapy: A Practical Intensity-modulated Radiation Therapy Planning and Delivery Approach to RTOG 0933. Journal of Medical Imaging and Radiation Sciences, 2015. 46(1): p. 78-84. 24. Ghia, A., et al., Distribution of Brain Metastases in Relation to the Hippocampus: Implications for Neurocognitive Functional Preservation. International Journal of Radiation Oncology*Biology*Physics, 2007. 68(4): p. 971-977. 25. Leksell, L., The stereotactic method and radiosurgery of the brain. Acta Chir Scand, 1951(102): p. 316-319. 26. Leksell, L., Stereotaxis and radiosurgery: An operative system. Thomas Publishers, 1971. 27. Bjartmarz, H. and S. Rehncrona, Comparison of Accuracy and Precision between Frame-Based and Frameless Stereotactic Navigation for Deep Brain Stimulation Electrode Implantation. Stereotactic and Functional Neurosurgery, 2007. 85(5): p. 235-242. 28. Treuer, H., et al., Impact of target point deviations on control and complication probabilities in stereotactic radiosurgery of AVMs and metastases. Radiother Oncol, 2006. 81(1): p. 25-32. 29. Novotny Jr, J., et al., Quality control of the stereotactic radiosurgery procedure with the polymer-gel dosimetry. Radiother. Oncol., 2002. 63(2): p. 223-230. 30. Cho, Y., et al., Evaluating Stress-related Uncertainties in Stereotactic Frame-based Localization for Gamma Knife Radiosurgery. Int J Radiat Oncol Biol Phys, 2009. 75(3, Supplement): p. S691-S692. 31. Theodorou, K., C. Kappas, and C. Tsokas, A new non-invasive and relocatable immobilization frame for fractionated stereotactic radiotherapy. Radiotherapy and Oncology, 1998. 47(3): p. 313-317. 32. Bova, F.J., et al., The university of Florida frameless high-precision stereotactic radiotherapy system. International Journal of Radiation Oncology*Biology*Physics, 1997. 38(4): p. 875-882. 33. Kooy, H.M., et al., Adaptation and verification of the relocatable gill-thomas-cosman frame in stereotactic radiotherapy. International Journal of Radiation Oncology*Biology*Physics, 1994. 30(3): p. 685-691. 34. Takahashi, T., et al., Measurement of repositioning accuracy during fractionated stereotactic radiotherapy for intracranial tumors using noninvasive fixation of BrainLAB radiotherapy equipment. International Journal of Radiation Oncology*Biology*Physics, 2006. 66(4, Supplement): p. S67-S70. 35. Das, S., et al., Geometric Uncertainties in High Precision Radiotherapy for Brain Tumors: A Prospective Study. Int J Radiat Oncol Biol Phys, 2011. 78(3, Supplement): p. S686. 36. Baumert, B.G., et al., Repositioning accuracy of fractionated stereotactic irradiation: assessment of isocentre alignment for different dental fixations by using sequential CT scanning. Radiother. Oncol., 2005. 74(1): p. 61-66. 37. Bednarz, G., et al., Report on a randomized trial comparing two forms of immobilization of the head for fractionated stereotactic radiotherapy. Medical Physics, 2009. 36(1): p. 12-17. 38. Boda-Heggemann, J., et al., Repositioning accuracy of two different mask systems—3D revisited: Comparison using true 3D/3D matching with cone-beam CT. Int J Radiat Oncol Biol Phys, 2006. 66(5): p. 1568-1575. 39. Chung, C., et al., Clinical Evaluation of a Novel Thermoplastic Mask System With Intrafraction Motion Monitoring Using IR Tracking and Cone Beam CT for Gamma Knife Radiosurgery. Int J Radiat Oncol Biol Phys, 2014. 90(1, Supplement): p. S848. 40. Clark, B.G., T. Teke, and K. Otto, Penumbra evaluation of the varian millennium and BrainLAB M3 multileaf collimators. International Journal of Radiation Oncology*Biology*Physics, 2006. 66(4, Supplement): p. S71-S75. 41. Cosgrove, V.P., et al., Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery. Radiother. Oncol,, 1999. 50(3): p. 325-335. 42. Almeida, T.V.R., et al., Positioning deviations in frameless and frame-based intracranial stereotactic radiosurgery. Radiation Physics and Chemistry, 2019: p. 108363. 43. Mackie, T.R., et al., Image guidance for precise conformal radiotherapy. International Journal of Radiation Oncology*Biology*Physics, 2003. 56(1): p. 89-105. 44. Han, C., et al., Dosimetric comparisons of helical tomotherapy treatment plans and step-and-shoot intensity-modulated radiosurgery treatment plans in intracranial stereotactic radiosurgery. Int J Radiat Oncol Biol Phys, 2006. 65(2): p. 608-616. 45. Yu, C. and D. Shepard, Treatment planning for stereotactic radiosurgery with photon beams. Technol Cancer Res Treat., 2003. 2(2): p. 93-104. 46. Adler, J.D., et al., Visual field preservation after multisession cyberknife radiosurgery for perioptic lesions. Neurosurgery, 2008. 62(Suppl 2): p. 733-43. 47. Andrews, D.W., et al., A review of 3 current radiosurgery systems. Surgical Neurology, 2006. 66(6): p. 559-564. 48. Gibbs, I.C., et al., Dosimetric quality assurance analysis of cyberknife extracranial radiosurgery of the spine. International Journal of Radiation Oncology*Biology*Physics, 2001. 51(3, Supplement 1): p. 252. 49. Ma, L., et al., A dosimetric comparison of fan-beam intensity modulated radiotherapy with gamma knife stereotactic radiosurgery for treating intermediate intracranial lesions. Int J Radiat Oncol Biol Phys, 1999. 45(5): p. 1325-1330. 50. Gevaert, T., et al., Dosimetric comparison of different treatment modalities for stereotactic radiosurgery of arteriovenous malformations and acoustic neuromas. Radiotherapy and Oncology, 2013. 106(2): p. 192-197. 51. Kim, H., et al., Tumor volume threshold for achieving improved conformity in VMAT and Gamma Knife stereotactic radiosurgery for vestibular schwannoma. Radiotherapy and Oncology, 2015. 115(2): p. 229-234. 52. Verellen, D., et al., Assessment of the uncertainties in dose delivery of a commercial system for linac-based stereotactic radiosurgery. Int J Radiat Oncol Biol Phys, 1999. 44(2): p. 421-433. 53. Seravalli, E., et al., A comprehensive evaluation of treatment accuracy, including end-to-end tests and clinical data, applied to intracranial stereotactic radiotherapy. Radiotherapy and Oncology, 2015. 116(1): p. 131-138. 54. Kestin, L., et al., Dose-response relationship with clinical outcome for lung stereotactic body radiotherapy (SBRT) delivered via online image guidance. Radiother Oncol, 2014. 110(3): p. 499-504. 55. Koshy, M., et al., Increasing radiation therapy dose is associated with improved survival in patients undergoing stereotactic body radiation therapy for stage I non-small-cell lung cancer. Int J Radiat Oncol Biol Phys, 2015. 91(2): p. 344-50. 56. Li, Q., et al., Stereotactic ablative radiotherapy (SABR) using 70 Gy in 10 fractions for non-small cell lung cancer: exploration of clinical indications. Radiother Oncol, 2014. 112(2): p. 256-61. 57. Martin, A. and A. Gaya, Stereotactic Body Radiotherapy: A Review. Clinical Oncology, 2010. 22(3): p. 157-172. 58. Nelson, J.W., et al., Stereotactic Body Radiotherapy for Lesions of the Spine and Paraspinal Regions. Int J Radiat Oncol Biol Phys, 2009. 73(5): p. 1369-1375. 59. Song, C.W., et al., Radiobiological basis of SBRT and SRS. Int J Clin Oncol, 2014. 19(4): p. 570-8. 60. Soldà, F., et al., Stereotactic radiotherapy (SABR) for the treatment of primary non-small cell lung cancer; Systematic review and comparison with a surgical cohort. Radiotherapy and Oncology, 2013. 109(1): p. 1-7. 61. Lee, W.-Y., et al., Outcomes and cost-effectiveness of gamma knife radiosurgery and whole brain radiotherapy for multiple metastatic brain tumors. Journal of Clinical Neuroscience, 2009. 16(5): p. 630-634. 62. Simonová, G., et al., Fractionated stereotactic radiotherapy with the Leksell Gamma Knife: feasibility study. Radiother. Oncol., 1995. 37(2): p. 108-116. 63. Paddick, I., A simple scoring ratio to index the conformity of radiosurgical treatment plans. J Neurosurg, 2000. 93(supplement 3): p. 219-222. 64. Riet, A.v.t., et al., A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate. Int J Radiat Oncol Biol Phys, 1997. 37(3): p. 731-736. 65. Lomax, N.J. and S.G. Scheib, Quantifying the degree of conformity in radiosurgery treatment planning. Int J Radiat Oncol Biol Phys, 2003. 55(5): p. 1409-1419. 66. Feuvret, L., et al., Conformity index: A review. Int J Radiat Oncol Biol Phys, 2006. 64(2): p. 333-342. 67. Shaw, E., et al., Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines. Int J Radiat Oncol Biol Phys, 1993. 27(5): p. 1231-9. 68. Knöös, T., I. Kristensen, and P. Nilsson, Volumetric and dosimetric evaluation of radiation treatment plans: radiation conformity index. International Journal of Radiation Oncology*Biology*Physics, 1998. 42(5): p. 1169-1176. 69. Paddick, I. and B. Lippitz, A simple dose gradient measurement tool to complement the conformity index. J Neurosurg, 2006. 105 Suppl: p. 194-201. 70. Massager, N., et al., Dosimetric and Clinical Analysis of Spatial Distribution of the Radiation Dose in Gamma Knife Radiosurgery for Vestibular Schwannoma. Int J Radiat Oncol Biol Phys, 2011. 81(4): p. e511-e518. 71. Balagamwala, E.H., et al., The Importance of the Conformality, Heterogeneity, and Gradient Indices in Evaluating Gamma Knife Radiosurgery Treatment Plans for Intracranial Meningiomas. Int J Radiat Oncol Biol Phys, 2012. 83(5): p. 1406-1413. 72. Reiner, B., et al., In Regard to Balagamwala et al. Int J Radiat Oncol Biol Phys, 2013. 85(5): p. 1154-1155. 73. Shehata, M.K., et al., Stereotatic radiosurgery of 468 brain metastases < or =2 cm: implications for SRS dose and whole brain radiation therapy. Int J Radiat Oncol Biol Phys, 2004. 59(1): p. 87-93. 74. Hazard, L.J., R.L. Jensen, and D.C. Shrieve, Role of stereotactic radiosurgery in the treatment of brain metastases. Am J Clin Oncol, 2005. 28(4): p. 403-10. 75. Hasegawa, T., et al., Long-term outcomes of Gamma Knife surgery for cavernous sinus meningioma. J Neurosurg, 2007. 107(4): p. 745-51. 76. Liscak, R., et al., Gamma knife radiosurgery of meningiomas in the cavernous sinus region. Acta Neurochir (Wien), 1999. 141(5): p. 473-80. 77. Pollock, B.E. and S.L. Stafford, Results of stereotactic radiosurgery for patients with imaging defined cavernous sinus meningiomas. Int J Radiat Oncol Biol Phys, 2005. 62(5): p. 1427-31. 78. Kondziolka, D., et al., Stereotactic radiosurgery for convexity meningiomas. J Neurosurg, 2009. 111(3): p. 458-63. 79. Ganz, J.C., W.A. Reda, and K. Abdelkarim, Gamma Knife surgery of large meningiomas: early response to treatment. Acta Neurochir (Wien), 2009. 151(1): p. 1-8. 80. Flannery, T.J., et al., Long-term control of petroclival meningiomas through radiosurgery. J Neurosurg, 2010. 112(5): p. 957-64. 81. Flickinger, J.C., et al., Evolution in technique for vestibular schwannoma radiosurgery and effect on outcome. Int J Radiat Oncol Biol Phys, 1996. 36(2): p. 275-280. 82. Niranjan, A., et al., Dose reduction improves hearing preservation rates after intracanalicular acoustic tumor radiosurgery. Neurosurgery, 1999. 45(4): p. 753-62; discussion 762-5. 83. Regis, J., et al., Radiosurgery: operative technique, pitfalls and tips. Prog Neurol Surg, 2008. 21: p. 54-64. 84. Rogers, C.L., et al., Gamma knife radiosurgery for trigeminal neuralgia: the initial experience of The Barrow Neurological Institute. Int J Radiat Oncol Biol Phys, 2000. 47(4): p. 1013-9. 85. Kondziolka, D., et al., Gamma Knife stereotactic radiosurgery for idiopathic trigeminal neuralgia. J Neurosurg, 2010. 112(4): p. 758-65. 86. Flickinger, J.C., et al., Does increased nerve length within the treatment volume improve trigeminal neuralgia radiosurgery? a prospective double-blind, randomized study. Int J Radiat Oncol Biol Phys, 2001. 51(2): p. 449-454. 87. Jeremy, G., Gamma Knife Neurosurgery. SpringerWienNewYork, 2011: p. 321-322. 88. Yamamoto, Y., et al., Interim report on the radiosurgical treatment of cerebral arteriovenous malformations. The influence of size, dose, time, and technical factors on obliteration rate. J Neurosurg, 1995. 83(5): p. 832-7. 89. Hasegawa, T., et al., Long-term results after stereotactic radiosurgery for patients with cavernous malformations. Neurosurgery, 2002. 50(6): p. 1190-7; discussion 1197-8. 90. Izawa, M., et al., Long-term complications after gamma knife surgery for arteriovenous malformations. J Neurosurg, 2005. 102 Suppl: p. 34-7. 91. Spatola, G., et al., Results of Gamma Knife anterior capsulotomy for refractory obsessive-compulsive disorder: results in a series of 10 consecutive patients. J Neurosurg, 2018: p. 1-8. 92. Ma, L., et al., Whole-procedural Radiological Accuracy for Delivering Multi-session Gamma Knife Radiosurgery With a Relocatable Frame System. Technology in Cancer Research and Treatment, 2013. 93. Bhatnagar, J.P., et al., First year experience with newly developed Leksell Gamma Knife Perfexion. J Med Phys, 2009. 34(3): p. 141-8. 94. Ruschin, M., et al., Investigation of intracranial peripheral dose arising from the treatment of large lesions with Leksell GammaKnife Perfexion. Medical Physics, 2009. 36(6): p. 2069-2073. 95. Sayer, F.T., et al., Initial Experience with the eXtend System: A Relocatable Frame System for Multiple-Session Gamma Knife Radiosurgery. World Neurosurgery, 2011. 75(5-6): p. 665-672. 96. Lindquist, C. and I. Paddick, The Leksell Gamma Knife Perfexion and comparisons with its predecessors. Neurosurgery, 2007. 61(3 Suppl): p. 130-40; discussion 140-1. 97. Jaffray, D.A., et al., Flat-panel cone-beam computed tomography for image-guided radiation therapy. International Journal of Radiation Oncology*Biology*Physics, 2002. 53(5): p. 1337-1349. 98. Lutz, W., K. Winston, and N. Maleki, A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys, 1988. 14(2): p. 373-81. 99. Ruschin, M., et al., Performance of a Novel Repositioning Head Frame for Gamma Knife Perfexion and Image-Guided Linac-Based Intracranial Stereotactic Radiotherapy. Int J Radiat Oncol Biol Phys, 2010. 78(1): p. 306-313. 100. Reiner, B., G. Wright, and P. Bownes, Commissioning of the Extend™ system for Gamma Knife®, in IPEM. 2011: London. 101. van Herk, M., et al., The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys, 2000. 47(4): p. 1121-1135. 102. McKenzie, A., M. van Herk, and B. Mijnheer, Margins for geometric uncertainty around organs at risk in radiotherapy. Radiother. Oncol., 2002. 62(3): p. 299-307. 103. van Herk, M., P. Remeijer, and J.V. Lebesque, Inclusion of geometric uncertainties in treatment plan evaluation. Int J Radiat Oncol Biol Phys, 2002. 52(5): p. 1407-1422. 104. Stroom, J.C., et al., Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. International Journal of Radiation Oncology*Biology*Physics, 1999. 43(4): p. 905-919. 105. Stroom, J.C. and B.J.M. Heijmen, Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report. Radiotherapy and Oncology, 2002. 64(1): p. 75-83. 106. Bethesda, M., ICRU Report 50. Prescribing, Recording, and Reporting Photon Beam Therapy. . International Commission on Radiation Units and Measurements, 1993. 107. Bethesda, M., ICRU Report 62. Prescribing, Recording, and Reporting Photon Beam Therapy (Supplement to ICRU Report 50). International Commission on Radiation Units and Measurements, , 1999. 108. ICRU Report 29. Dose Specification for Reporting External Beam Therapy with Photons and Electrons. 1978. 109. Measurements, I.I.C.o.R.U.a., Prescribing, recording, and reporting photon-beam intensity-modulated radiation therapy (IMRT). ICRU Report 83. J ICRU, 2010. 10: p. 1-106. 110. Torrens, M., et al., THE STANDARDISATION OF TERMINOLOGY IN RADIOSURGERY: Report from the Standardization Committee of the International Leksell Gamma Knife Society (DRAFT DOCUMENT [3.3] FOR CIRCULATION TO LGKS MEMBERS), 2012. 111. Torrens, M., et al., Standardization of terminology in stereotactic radiosurgery: Report from the Standardization Committee of the International Leksell Gamma Knife Society: special topic. J Neurosurg., 2014. Suppl 121: p. 2-15. 112. Regine, W.F., et al., Neurocognitive outcome in brain metastases patients treated with accelerated-fractionation vs. accelerated-hyperfractionated radiotherapy: an analysis from Radiation Therapy Oncology Group Study 91-04. Int J Radiat Oncol Biol Phys, 2001. 51(3): p. 711-717. 113. Korytko, T., et al., 12 Gy gamma knife radiosurgical volume is a predictor for radiation necrosis in non-AVM intracranial tumors. Int J Radiat Oncol Biol Phys, 2006. 64(2): p. 419-424. 114. Lyman, J.T., Complication Probability as Assessed from Dose-Volume Histograms. Radiation Research, 1985. 104(2): p. S13-S19. 115. Burman, C., et al., Fitting of normal tissue tolerance data to an analytic function Int J Radiat Oncol Biol Phys, 1991. 21(1): p. 123-135. 116. Bentzen, S.M., et al., Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): An Introduction to the Scientific Issues. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S3-S9. 117. Lyman, J.T., Normal tissue complication probabilities: Variable dose per fraction. Int J Radiat Oncol Biol Phys, 1992. 22(2): p. 247-250. 118. Emami, B., et al., Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys, 1991. 21(1): p. 109-122. 119. Spring, E. and P. Holmberg, Evaluation of experimental irradiation fractionation with the single-hit, multi-target model. Acta Radiol Ther Phys Biol, 1968. 7(4): p. 297-306. 120. Elkind, M. and G. Whitmore, The radiobiology of cultured mammalian cells. Gordon & Breach, 1967. New York. 121. Lea, D.E., R.B. Haines, and E. Bretscher, The bactericidal action of X-rays, neutrons and radioactive radiations. J Hyg (Lond), 1941. 41(1): p. 1-16. 122. Lea, D.E. and C.A. Coulson, The distribution of the numbers of mutants in bacterial populations. J Genet, 1949. 49(3): p. 264-85. 123. Nomiya, T., Discussions on target theory: past and present. J Radiat Res, 2013. 54(6): p. 1161-3. 124. Brenner, D.J., The Linear-Quadratic Model Is an Appropriate Methodology for Determining Isoeffective Doses at Large Doses Per Fraction. Seminars in Radiation Oncology, 2008. 18(4): p. 234-239. 125. Kirkpatrick, J.P., J.J. Meyer, and L.B. Marks, The Linear-Quadratic Model Is Inappropriate to Model High Dose per Fraction Effects in Radiosurgery. Seminars in Radiation Oncology, 2008. 18(4): p. 240-243. 126. Courdi, A., High doses per fraction and the linear-quadratic model. Radiother. Oncol., 2010. 94(1): p. 121-122. 127. Hoban, P.W., L.C. Jones, and B.G. Clark, Modeling late effects in hypofractionated stereotactic radiotherapy. Int J Radiat Oncol Biol Phys, 1999. 43(1): p. 199-210. 128. Iwata, H., et al., Estimation of Errors Associated With Use of Linear-Quadratic Formalism for Evaluation of Biologic Equivalence Between Single and Hypofractionated Radiation Doses: An In Vitro Study. Int J Radiat Oncol Biol Phys, 2009. 75(2): p. 482-488. 129. Carlson, D.J., et al., Hypofractionation Results in Reduced Tumor Cell Kill Compared to Conventional Fractionation for Tumors With Regions of Hypoxia. Int J Radiat Oncol Biol Phys, 2011. 79(4): p. 1188-1195. 130. Jones, B., et al., Biological equivalent dose assessment of the consequences of hypofractionated radiotherapy. Int J Radiat Oncol Biol Phys, 2000. 47(5): p. 1379-1384. 131. Park, C., et al., Universal Survival Curve and Single Fraction Equivalent Dose: Useful Tools in Understanding Potency of Ablative Radiotherapy. Int J Radiat Oncol Biol Phys, 2008. 70(3): p. 847-852. 132. Clark, B.G., et al., The integral biologically effective dose to predict brain stem toxicity of hypofractionated stereotactic radiotherapy. Int J Radiat Oncol Biol Phys, 1998. 40(3): p. 667-675. 133. Kong, C., et al., A new index comparable to BED for evaluating the biological efficacy of hypofractionated radiotherapy schemes on early stage non-small cell lung cancer: Analysis of data from the literature. Lung Cancer, 2014. 84(1): p. 7-12. 134. Voyant, C., et al., Biological effects and equivalent doses in radiotherapy: A software solution. Reports of Practical Oncology & Radiotherapy, 2014. 19(1): p. 47-55. 135. Fleming, C., et al., A Method for the Prediction of Late Organ-at-Risk Toxicity After Radiotherapy of the Prostate Using Equivalent Uniform Dose. International Journal of Radiation Oncology*Biology*Physics, 2011. 80(2): p. 608-613. 136. Liu, F., et al., Modeling Regional Sensitivity of Radiation Pneumonitis using Multi-institutional EUD Atlases from Phase I Dose Escalation Protocols for Non-small Cell Lung Cancer. Int J Radiat Oncol Biol Phys, 2010. 78(3, Supplement 1): p. S46-S46. 137. Bentzen, S.M., et al., Biomarkers and Surrogate Endpoints for Normal-Tissue Effects of Radiation Therapy: The Importance of Dose-Volume Effects. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S145-S150. 138. Marks, L.B., R.K. Ten Haken, and M.K. Martel, Guest Editor's Introduction to QUANTEC: A Users Guide. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S1-S2. 139. Lawrence, Y.R., et al., Radiation Dose-Volume Effects in the Brain. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S20-S27. 140. Mayo, C., E. Yorke, and T.E. Merchant, Radiation Associated Brainstem Injury. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S36-S41. 141. Zaider, M. and H.I. Amols, A little to a lot or a lot to a little: is NTCP always minimized in multiport therapy? Int J Radiat Oncol Biol Phys, 1998. 41(4): p. 945-950. 142. Peng, L., et al., Updated risk models demonstrate low risk of symptomatic radionecrosis following stereotactic radiosurgery for brain metastases. Surg Neurol Int, 2019. 10: p. 32. 143. Laura Licon, A., et al., A quantitative measure for radiation treatment plan quality. J buon, 2018. 23(5): p. 1460-1466. 144. Beaton, L., et al., Cardiac death after breast radiotherapy and the QUANTEC cardiac guidelines. Clin Transl Radiat Oncol, 2019. 19: p. 39-45. 145. Yen, C.-P. and L. Steiner, Gamma Knife Surgery for Brainstem Arteriovenous Malformations. World Neurosurgery, 2011. 76(1–2): p. 87-95. 146. Jung, E.W., et al., Gamma Knife radiosurgery in the management of brainstem metastases. Clinical Neurology and Neurosurgery, 2013. 115(10): p. 2023-2028. 147. Ma, L., et al., Apparatus dependence of normal brain tissue dose in stereotactic radiosurgery for multiple brain metastases. Journal of Neurosurgery, 2011. 114(6): p. 1580-1584. 148. Park, S.-H., et al., Gamma knife radiosurgery for multiple brain metastases from lung cancer. Journal of Clinical Neuroscience, 2009. 16(5): p. 626-629. 149. Gevaert, T., et al., Dosimetric comparison of different treatment modalities for stereotactic radiosurgery of arteriovenous malformations and acoustic neuromas. Radiother. Oncol., 2013. 106(0): p. 192-197. 150. Al-Shamy, G. and R. Sawaya, Management of brain metastases: the indispensable role of surgery. J Neurooncol, 2009. 92((3)): p. 275-82. 151. Feuvret, L., et al., Stereotactic radiotherapy for large solitary brain metastases. Cancer/Radiothérapie, 2014. 18(2): p. 97-106. 152. Märtens, B., et al., Hypofractionated stereotactic radiotherapy of limited brain metastases: a single-centre individualized treatment approach. BMC Cancer., 2012. 12. 153. Mehta, M., et al., A cost-effectiveness and cost-utility analysis of radiosurgery vs. resection for single-brain metastases. Int J Radiat Oncol Biol Phys, 1997. 39(2): p. 445-454. 154. Yuan, J., et al., Hypofractionation Regimens for Stereotactic Radiotherapy for Large Brain Tumors. Int J Radiat Oncol Biol Phys, 2008. 72(2): p. 390-397. 155. Ganz, J.C., et al., Protection of the anterior visual pathways during gamma knife treatment of meningiomas. British Journal of Neurosurgery, 2010. 24(3): p. 233-243. 156. Kim, Y.-J., et al., Single-Dose Versus Fractionated Stereotactic Radiotherapy for Brain Metastases. Int J Radiat Oncol Biol Phys, 2011. 81(2): p. 483-489. 157. Tuniz, F., et al., Multisession cyberknife stereotactic radiosurgery of large, benign cranial base tumors: preliminary study. Neurosurgery, 2009. 65(5): p. 898-907. 158. Schlesinger, D., et al., Interfraction and intrafraction performance of the Gamma Knife Extend system for patient positioning and immobilization. J Neurosurg. , 2012. 117(Suppl:): p. 217-24. 159. Ma, L., et al., Impact of Millimeter-Level Margins on Peripheral Normal Brain Sparing for Gamma Knife Radiosurgery. Int J Radiat Oncol Biol Phys, 2014. 89(1): p. 206-213. 160. Devriendt, D., et al., Five-fraction Gamma Knife radiosurgery using the Extend relocatable system for benign neoplasms close to optic pathways. Practical Radiation Oncology, 2015(0). 161. Goh, A.S.C., et al., Benign Orbital Apex Tumors Treated with Multisession Gamma Knife Radiosurgery. Ophthalmology, 2013. 120(3): p. 635-641. 162. Kim, M.-S., et al., Gamma knife radiosurgery for orbital tumors. Clinical Neurology and Neurosurgery, 2008. 110(10): p. 1003-1007. 163. Nguyen, J.H., et al., Multisession Gamma Knife Radiosurgery: A Preliminary Experience with a Noninvasive, Relocatable Frame. World Neurosurgery, 2014. 82(6): p. 1256-1263. 164. Gevaert, T., et al., Setup Accuracy of the Novalis ExacTrac 6DOF System for Frameless Radiosurgery. International Journal of Radiation Oncology*Biology*Physics, 2012. 82(5): p. 1627-1635. 165. Murphy, M.J., Intrafraction Geometric Uncertainties in Frameless Image-Guided Radiosurgery. Int J Radiat Oncol Biol Phys, 2009. 73(5): p. 1364-1368. 166. Murphy, M.J., et al., Patterns of patient movement during frameless image-guided radiosurgery. Int J Radiat Oncol Biol Phys, 2003. 55(5): p. 1400-1408. 167. Masi, L., et al., Cone Beam CT Image Guidance for Intracranial Stereotactic Treatments: Comparison With a Frame Guided Set-Up. Int J Radiat Oncol Biol Phys, 2008. 71(3): p. 926-933. 168. Wangerid, T., et al., Implication of using MRI co-registered with CT in Leksell Gamma Knife® dose planning for patients with vestibular schwannoma. Clinical Neurology and Neurosurgery, 2015. 138: p. 10-15. 169. Shaw, E., et al., Single dose radiosurgical treatment of recurrent previously irradiated primary brain tumors and brain metastases: final report of RTOG protocol 90-05. Int J Radiat Oncol Biol Phys, 2000. 47(2): p. 291-8. 170. Lee, C.C., et al., Large intracranial metastatic tumors treated by Gamma Knife surgery: outcomes and prognostic factors. J Neurosurg, 2014. 120(1): p. 52-9. 171. Marks, L.B., et al., Use of Normal Tissue Complication Probability Models in the Clinic. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S10-S19. 172. Mayo, C., et al., Radiation Dose-Volume Effects of Optic Nerves and Chiasm. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S28-S35. 173. Choi, C.Y.H., et al., Stereotactic Radiosurgery of the Postoperative Resection Cavity for Brain Metastases: Prospective Evaluation of Target Margin on Tumor Control. Int J Radiat Oncol Biol Phys, 2012. 84(2): p. 336-342. 174. Meyer, J., et al., Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table. Int J Radiat Oncol Biol Phys, 2007. 67(4): p. 1220-1228. 175. Millar, W.T., et al., The role of the concept of biologically effective dose (BED) in treatment planning in radiosurgery. Physica Medica, 2015. 31(6): p. 627-633. 176. Flickinger, J.C., et al., A multi-institutional analysis of complication outcomes after arteriovenous malformation radiosurgery. Int J Radiat Oncol Biol Phys, 1999. 44(1): p. 67-74. 177. Flickinger, J.C., et al., Development of a model to predict permanent symptomatic postradiosurgery injury for arteriovenous malformation patients. Int J Radiat Oncol Biol Phys, 2000. 46(5): p. 1143-1148. 178. Chin, L., L. Ma, and S. DiBiase, Radiation necrosis following gamma knife surgery: a case-controlled comparison of treatment parameters and long-term clinical follow up. J Neurosurg., 2001. 94(6): p. 899-904. 179. Blonigen, B.J., et al., Irradiated Volume as a Predictor of Brain Radionecrosis After Linear Accelerator Stereotactic Radiosurgery. Int J Radiat Oncol Biol Phys, 2010. 77(4): p. 996-1001. 180. Broemme, J., et al., Adjuvant therapy after resection of brain metastases. Frameless image-guided LINAC-based radiosurgery and stereotactic hypofractionated radiotherapy. Strahlenther Onkol, 2013. 189(9): p. 765-70. 181. Davidson, L., et al., Delayed toxicity from gamma knife radiosurgery to lesions in and adjacent to the brainstem. Journal of Clinical Neuroscience, 2009. 16(9): p. 1139-1147. 182. Johnson, M.D., et al., Analysis of Risk Factors for Development of Radiation Necrosis Following Gamma Knife Radiosurgery for Brain Metastases. International Journal of Radiation Oncology*Biology*Physics, 2013. 87(2, Supplement): p. S279-S280. 183. Kondziolka, D., et al., Histological effects of trigeminal nerve radiosurgery in a primate model: implications for trigeminal neuralgia radiosurgery. Neurosurgery, 2000. 46(4): p. 971-6; discussion 976-7. 184. Sheehan, J., et al., Gamma knife surgery for trigeminal schwannoma. J Neurosurg, 2007. 106(5): p. 839-45. 185. Wright, G., et al., Validity of the use of nose tip motion as a surrogate for intracranial motion in mask-fixated frameless Gamma Knife® Icon™ therapy. Journal of Radiosurgery & SBRT 2017. 4(4): p. 289-301. 186. Fowler, J.F., The linear-quadratic formula and progress in fractionated radiotherapy. Br J Radiol, 1989. 62(740): p. 679-694. 187. Thames, H.D., et al., Time-dose factors in radiotherapy: a review of the human data. Radiother. Oncol., 1990. 19(3): p. 219-235. 188. Bostrom, J.P., et al., Risk-adapted single or fractionated stereotactic high-precision radiotherapy in a pooled series of nonfunctioning pituitary adenomas: high local control and low toxicity. Strahlenther Onkol, 2014. 190(12): p. 1095-103. 189. Kuperman, V.Y., Effect of radiation protraction on BED in the case of large fraction dose. Med Phys, 2013. 40(8): p. 081716. 190. Zhao, L., et al., A generalized target theory and its applications. Scientific Reports, 2015. 5: p. 14568. 191. Wright, G., et al., Quantifying and improving the efficiency of Gamma Knife treatment plans for brain metastases: results of a 1-year audit. J Neurosurg, 2014. 121 Suppl: p. 44-50. 192. McMahon, S.J., The linear quadratic model: usage, interpretation and challenges. Physics in Medicine & Biology, 2018. 64(1): p. 01TR01. 193. Wang, J., et al., A Generalized Linear-Quadratic Model for Radiosurgery, Stereotactic Body Radiation Therapy, and High-Dose Rate Brachytherapy. Science translational medicine, 2010. 2: p. 39ra48. 194. Crispin-Ortuzar, M., et al., A radiobiological model of radiotherapy response and its correlation with prognostic imaging variables. Physics in Medicine and Biology, 2017. 62(7): p. 2658-2674. 195. Williams, J.A., Fractionated stereotactic radiotherapy (FSR) for acoustic neuromas. Int J Radiat Oncol Biol Phys, 2000. 48(3, Supplement 1): p. 253-254. 196. Sweeney, R., et al., A simple and non-invasive vacuum mouthpiece-based head fixation system for high precision radiotherapy. Strahlenther Onkol. , 2001. 177(1): p. 43-7. 197. van Santvoort, J., R. Wiggenraad, and P. Bos, Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning. Int J Radiat Oncol Biol Phys, 2008. 72(1): p. 261-267."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.789407"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/25176/1/Reiner_B_School_of_Medicine_PhD_2018.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Introduction: The Gamma Knife (GK) was originally introduced as a radiotherapy unit for solid brain lesions. The original skull-attached G-frame enabled submillimetre accuracy but allowed only single-fraction treatments, thus limiting to small lesion treatments. To enable fractionated Stereotactic Radiosurgery, the GK Perfexion model (with eXtend) was introduced leading to new questions: • What is the repositioning system accuracy? • What effect have positional uncertainties for the target; and for normal tissue (NT) and Organs at risk (OAR)? • How can positional uncertainties be handled? Material and Method: eXtend uncertainty was investigated using trigger levels of the vacuum-surveilled patient positioning mouthpiece, measured for ten patients’ dental models mounted on a 0.05mm-accuracy computer-controlled positioner. The dosimetric effect of these displacements in a single fraction was evaluated by calculating minimum dose, coverage and conformity-index changes for displacements of 0 to 4mm.The impact of positional displacements for 3 and 5 fraction treatments was evaluated for targets and organs-at-risk (OaR) by calculating total doses with simulated displacements of 0-4mm in combinations of X, Y, and Z directions for nine patients (in total almost 300 sumPlans). All plans were prescribed to the 50% isodose. Effects were calculated in physical dose and in biological effective dose (BED). Finally, from this a novel approach to minimize effects of displacement was proposed and feasibility-tested for 5-fraction plans. Instead of applying margins to cover potential uncertainties, a correction is applied in the last two fractions only after any observed systematic uncertainty is quantified in the first three fractions. 100 displacement scenarios were tested, comparing for each the dose volume histogram (DVH) and dose profiles and the total dose with and without the correction procedure. Results: Mean positional uncertainty with a clinical vacuum setting was 0.15mm (SD ±0.05mm, range 0.05-0.29mm) and 0.33° (SD ±0.15°, 0.05°-1.0°). The most critical parameter in the dose distribution is minimum dose D99%. In the evaluated scenarios D99% fell by 2% for a displacement of 0.5mm and 16% with 2mm in X or Y direction and >20% in Z direction, dependent on arrangement. Moving to hypofractionation increases the BED inside the target and reduces it outside, i.e. the dose gradient is increased at the 50% (prescription) isodose. Displacement in opposing directions is predominantly random, which reduces the dose gradient but does not introduce an underdosage to the target for displacements of up to 2 mm. At the same time the BED to OAR is increased but remains below single fraction dose. Feasibility testing the proposed correction method showed a significant improvement of the total BED indicating the method’s potential. Discussion: Positional uncertainty is generally low, better than 0.5mm for Perfexion whilst the later GK version, Icon. starts treatment with minimal uncertainties following an initial Cone Beam CT (CBCT). However, for both treatment units, target movement during treatment is possible and may be up to 2mm. The most critical aspect is underdosage of the target. Prescribing the dose to 50% reduces random uncertainty effects and ensures BED is at an optimal value (gradient) to avoid underdosage and protect OAR. A novel strategy is proposed and feasibility-tested to correct positional uncertainties, showing improved dose distribution in the scenarios tested. However, this test was for static displacements only. GK Icon corrects any positional displacement observed at the initial CBCT, so the correction method would only be needed when the system identifies further movement. For practical clinical use, further investigation is needed."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Assessment of the potential and risk of fractionated stereotactic radiosurgery for brain lesions using the Gamma Knife system."]}]}],"canonical_facts":{"dc:contributor.advisor":["Buckley, David","Thwaites, David"],"dc:creator":["Reiner, Beatrice"],"dc:date":["2018-12"],"dc:date.issued":["2018-12"],"dc:description.abstract":["Introduction: The Gamma Knife (GK) was originally introduced as a radiotherapy unit for solid brain lesions. The original skull-attached G-frame enabled submillimetre accuracy but allowed only single-fraction treatments, thus limiting to small lesion treatments. To enable fractionated Stereotactic Radiosurgery, the GK Perfexion model (with eXtend) was introduced leading to new questions: • What is the repositioning system accuracy? • What effect have positional uncertainties for the target; and for normal tissue (NT) and Organs at risk (OAR)? • How can positional uncertainties be handled? Material and Method: eXtend uncertainty was investigated using trigger levels of the vacuum-surveilled patient positioning mouthpiece, measured for ten patients’ dental models mounted on a 0.05mm-accuracy computer-controlled positioner. The dosimetric effect of these displacements in a single fraction was evaluated by calculating minimum dose, coverage and conformity-index changes for displacements of 0 to 4mm.The impact of positional displacements for 3 and 5 fraction treatments was evaluated for targets and organs-at-risk (OaR) by calculating total doses with simulated displacements of 0-4mm in combinations of X, Y, and Z directions for nine patients (in total almost 300 sumPlans). All plans were prescribed to the 50% isodose. Effects were calculated in physical dose and in biological effective dose (BED). Finally, from this a novel approach to minimize effects of displacement was proposed and feasibility-tested for 5-fraction plans. Instead of applying margins to cover potential uncertainties, a correction is applied in the last two fractions only after any observed systematic uncertainty is quantified in the first three fractions. 100 displacement scenarios were tested, comparing for each the dose volume histogram (DVH) and dose profiles and the total dose with and without the correction procedure. Results: Mean positional uncertainty with a clinical vacuum setting was 0.15mm (SD ±0.05mm, range 0.05-0.29mm) and 0.33° (SD ±0.15°, 0.05°-1.0°). The most critical parameter in the dose distribution is minimum dose D99%. In the evaluated scenarios D99% fell by 2% for a displacement of 0.5mm and 16% with 2mm in X or Y direction and >20% in Z direction, dependent on arrangement. Moving to hypofractionation increases the BED inside the target and reduces it outside, i.e. the dose gradient is increased at the 50% (prescription) isodose. Displacement in opposing directions is predominantly random, which reduces the dose gradient but does not introduce an underdosage to the target for displacements of up to 2 mm. At the same time the BED to OAR is increased but remains below single fraction dose. Feasibility testing the proposed correction method showed a significant improvement of the total BED indicating the method’s potential. Discussion: Positional uncertainty is generally low, better than 0.5mm for Perfexion whilst the later GK version, Icon. starts treatment with minimal uncertainties following an initial Cone Beam CT (CBCT). However, for both treatment units, target movement during treatment is possible and may be up to 2mm. The most critical aspect is underdosage of the target. Prescribing the dose to 50% reduces random uncertainty effects and ensures BED is at an optimal value (gradient) to avoid underdosage and protect OAR. A novel strategy is proposed and feasibility-tested to correct positional uncertainties, showing improved dose distribution in the scenarios tested. However, this test was for static displacements only. GK Icon corrects any positional displacement observed at the initial CBCT, so the correction method would only be needed when the system identifies further movement. For practical clinical use, further investigation is needed."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.789407"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/25176/1/Reiner_B_School_of_Medicine_PhD_2018.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Academic Unit of Medical Physics (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/25176/"],"dc:relation.references":["1. Reiner, B., et al., Quantifying the trigger level of the vacuum surveillance system of the Gamma-Knife eXtend™ positioning system and evaluating the potential impact on dose delivery. Journal of Radiosurgery & SBRT, 2016. 4(1): p. 31-42. 2. Reiner, B., et al., Quantifying the effects of positional uncertainties and estimating margins for Gamma-Knife® fractionated radiosurgery of large brain metastases. Journal of Radiosurgery & SBRT 2017. 4(4): p. 275-287. 3. Lippitz, B., et al., Stereotactic radiosurgery in the treatment of brain metastases: The current evidence. Cancer Treatment Reviews, 2013. 40(1): p. 48-59. 4. Andrews, D.W., et al., Whole brain radiation therapy with or without stereotactic radiosurgery boost for patients with one to three brain metastases: phase III results of the RTOG 9508 randomised trial. The Lancet, 2004. 363(9422): p. 1665. 5. UK, C.r. Brain, other CNS and intracranial tumours Key Facts. 2014-2016 30/09/19 [cited 2019 15 Sept.]; Available from: http://www.cancerresearchuk.org/cancer-info/cancerstats/keyfacts/brain-cancer/. 6. Baumert, B.G., et al., Fractionated stereotactic radiotherapy boost after post-operative radiotherapy in patients with high-grade gliomas. Radiotherapy and Oncology, 2003. 67(2): p. 183-190. 7. Andrews, D.W., et al., Whole brain radiation therapy with or without stereotactic radiosurgery boost for patients with one to three brain metastases: phase III results of the RTOG 9508 randomised trial. The Lancet, 2004. 363(9422): p. 1665-1672. 8. Choi, C.Y.H., et al., Stereotactic Radiosurgery of the Postoperative Resection Cavity for Brain Metastases: Prospective Evaluation of Target Margin on Tumor Control. International Journal of Radiation Oncology*Biology*Physics, 2012. 84(2): p. 336-342. 9. Asher, A.L., et al., A New Treatment Paradigm: Neoadjuvant Radiosurgery Before Surgical Resection of Brain Metastases With Analysis of Local Tumor Recurrence. International Journal of Radiation Oncology*Biology*Physics, 2014. 88(4): p. 899-906. 10. U. M. Lütolf and U. Ulmer, clinical practice. University Hospital Zurich, Switzerland, 1995-2000. personal communication. 11. Balducci, M., et al., Radiosurgery or Fractionated Stereotactic Radiotherapy plus Whole-brain Radioherapy in Brain Oligometastases: A Long-term Analysis. Anticancer Res, 2015. 35(5): p. 3055-9. 12. Barani, I.J. and D.A. Larson, Radiation therapy of glioblastoma. Cancer Treat Res, 2015. 163: p. 49-73. 13. Chang, E.L., et al., Neurocognition in patients with brain metastases treated with radiosurgery or radiosurgery plus whole-brain irradiation: a randomised controlled trial. The Lancet Oncology, 2009. 10(11): p. 1037-1044. 14. Choi, C.Y.H., et al., What Is the Optimal Treatment of Large Brain Metastases? An Argument for a Multidisciplinary Approach. Int J Radiat Oncol Biol Phys, 2012. 84(3): p. 688-693. 15. Ernst-Stecken, A., et al., Phase II trial of hypofractionated stereotactic radiotherapy for brain metastases: Results and toxicity. Radiother. Oncol., 2006. 81(1): p. 18-24. 16. Mehta, M.P., et al., The American Society for Therapeutic Radiology and Oncology (ASTRO) evidence-based review of the role of radiosurgery for brain metastases. Int J Radiat Oncol Biol Phys, 2005. 63(1): p. 37-46. 17. Patchell, R.A., et al., Postoperative radiotherapy in the treatment of single metastases to the brain: a randomized trial. Jama, 1998. 280(17): p. 1485-9. 18. Patchell, R.A., The management of brain metastases. Cancer Treat Rev, 2003. 29(6): p. 533-40. 19. Skeie, B.S., et al., Gamma Knife Surgery versus Reoperation for Recurrent Glioblastoma Multiforme. World Neurosurgery, 2012. 78(6): p. 658-669. 20. Hughes, R.T., et al., Initial SRS for Patients With 5 to 15 Brain Metastases: Results of a Multi-Institutional Experience. International Journal of Radiation Oncology*Biology*Physics, 2019. 104(5): p. 1091-1098. 21. Dirven, L., et al., Impact of Radiation Target Volume on Health-Related Quality of Life in Patients With Low-Grade Glioma in the 2-Year Period Post Treatment: A Secondary Analysis of the EORTC 22033-26033. International Journal of Radiation Oncology*Biology*Physics, 2019. 104(1): p. 90-100. 22. Fan, X.-W., et al., Simultaneously avoiding the hippocampus and hypothalamic-pituitary axis during whole brain radiotherapy: A planning study. Medical Dosimetry, 2019. 44(2): p. 130-135. 23. Andreas, J.J.M. and V. Kundapur, Hippocampus Avoidance Whole-brain Radiation Therapy: A Practical Intensity-modulated Radiation Therapy Planning and Delivery Approach to RTOG 0933. Journal of Medical Imaging and Radiation Sciences, 2015. 46(1): p. 78-84. 24. Ghia, A., et al., Distribution of Brain Metastases in Relation to the Hippocampus: Implications for Neurocognitive Functional Preservation. International Journal of Radiation Oncology*Biology*Physics, 2007. 68(4): p. 971-977. 25. Leksell, L., The stereotactic method and radiosurgery of the brain. Acta Chir Scand, 1951(102): p. 316-319. 26. Leksell, L., Stereotaxis and radiosurgery: An operative system. Thomas Publishers, 1971. 27. Bjartmarz, H. and S. Rehncrona, Comparison of Accuracy and Precision between Frame-Based and Frameless Stereotactic Navigation for Deep Brain Stimulation Electrode Implantation. Stereotactic and Functional Neurosurgery, 2007. 85(5): p. 235-242. 28. Treuer, H., et al., Impact of target point deviations on control and complication probabilities in stereotactic radiosurgery of AVMs and metastases. Radiother Oncol, 2006. 81(1): p. 25-32. 29. Novotny Jr, J., et al., Quality control of the stereotactic radiosurgery procedure with the polymer-gel dosimetry. Radiother. Oncol., 2002. 63(2): p. 223-230. 30. Cho, Y., et al., Evaluating Stress-related Uncertainties in Stereotactic Frame-based Localization for Gamma Knife Radiosurgery. Int J Radiat Oncol Biol Phys, 2009. 75(3, Supplement): p. S691-S692. 31. Theodorou, K., C. Kappas, and C. Tsokas, A new non-invasive and relocatable immobilization frame for fractionated stereotactic radiotherapy. Radiotherapy and Oncology, 1998. 47(3): p. 313-317. 32. Bova, F.J., et al., The university of Florida frameless high-precision stereotactic radiotherapy system. International Journal of Radiation Oncology*Biology*Physics, 1997. 38(4): p. 875-882. 33. Kooy, H.M., et al., Adaptation and verification of the relocatable gill-thomas-cosman frame in stereotactic radiotherapy. International Journal of Radiation Oncology*Biology*Physics, 1994. 30(3): p. 685-691. 34. Takahashi, T., et al., Measurement of repositioning accuracy during fractionated stereotactic radiotherapy for intracranial tumors using noninvasive fixation of BrainLAB radiotherapy equipment. International Journal of Radiation Oncology*Biology*Physics, 2006. 66(4, Supplement): p. S67-S70. 35. Das, S., et al., Geometric Uncertainties in High Precision Radiotherapy for Brain Tumors: A Prospective Study. Int J Radiat Oncol Biol Phys, 2011. 78(3, Supplement): p. S686. 36. Baumert, B.G., et al., Repositioning accuracy of fractionated stereotactic irradiation: assessment of isocentre alignment for different dental fixations by using sequential CT scanning. Radiother. Oncol., 2005. 74(1): p. 61-66. 37. Bednarz, G., et al., Report on a randomized trial comparing two forms of immobilization of the head for fractionated stereotactic radiotherapy. Medical Physics, 2009. 36(1): p. 12-17. 38. Boda-Heggemann, J., et al., Repositioning accuracy of two different mask systems—3D revisited: Comparison using true 3D/3D matching with cone-beam CT. Int J Radiat Oncol Biol Phys, 2006. 66(5): p. 1568-1575. 39. Chung, C., et al., Clinical Evaluation of a Novel Thermoplastic Mask System With Intrafraction Motion Monitoring Using IR Tracking and Cone Beam CT for Gamma Knife Radiosurgery. Int J Radiat Oncol Biol Phys, 2014. 90(1, Supplement): p. S848. 40. Clark, B.G., T. Teke, and K. Otto, Penumbra evaluation of the varian millennium and BrainLAB M3 multileaf collimators. International Journal of Radiation Oncology*Biology*Physics, 2006. 66(4, Supplement): p. S71-S75. 41. Cosgrove, V.P., et al., Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery. Radiother. Oncol,, 1999. 50(3): p. 325-335. 42. Almeida, T.V.R., et al., Positioning deviations in frameless and frame-based intracranial stereotactic radiosurgery. Radiation Physics and Chemistry, 2019: p. 108363. 43. Mackie, T.R., et al., Image guidance for precise conformal radiotherapy. International Journal of Radiation Oncology*Biology*Physics, 2003. 56(1): p. 89-105. 44. Han, C., et al., Dosimetric comparisons of helical tomotherapy treatment plans and step-and-shoot intensity-modulated radiosurgery treatment plans in intracranial stereotactic radiosurgery. Int J Radiat Oncol Biol Phys, 2006. 65(2): p. 608-616. 45. Yu, C. and D. Shepard, Treatment planning for stereotactic radiosurgery with photon beams. Technol Cancer Res Treat., 2003. 2(2): p. 93-104. 46. Adler, J.D., et al., Visual field preservation after multisession cyberknife radiosurgery for perioptic lesions. Neurosurgery, 2008. 62(Suppl 2): p. 733-43. 47. Andrews, D.W., et al., A review of 3 current radiosurgery systems. Surgical Neurology, 2006. 66(6): p. 559-564. 48. Gibbs, I.C., et al., Dosimetric quality assurance analysis of cyberknife extracranial radiosurgery of the spine. International Journal of Radiation Oncology*Biology*Physics, 2001. 51(3, Supplement 1): p. 252. 49. Ma, L., et al., A dosimetric comparison of fan-beam intensity modulated radiotherapy with gamma knife stereotactic radiosurgery for treating intermediate intracranial lesions. Int J Radiat Oncol Biol Phys, 1999. 45(5): p. 1325-1330. 50. Gevaert, T., et al., Dosimetric comparison of different treatment modalities for stereotactic radiosurgery of arteriovenous malformations and acoustic neuromas. Radiotherapy and Oncology, 2013. 106(2): p. 192-197. 51. Kim, H., et al., Tumor volume threshold for achieving improved conformity in VMAT and Gamma Knife stereotactic radiosurgery for vestibular schwannoma. Radiotherapy and Oncology, 2015. 115(2): p. 229-234. 52. Verellen, D., et al., Assessment of the uncertainties in dose delivery of a commercial system for linac-based stereotactic radiosurgery. Int J Radiat Oncol Biol Phys, 1999. 44(2): p. 421-433. 53. Seravalli, E., et al., A comprehensive evaluation of treatment accuracy, including end-to-end tests and clinical data, applied to intracranial stereotactic radiotherapy. Radiotherapy and Oncology, 2015. 116(1): p. 131-138. 54. Kestin, L., et al., Dose-response relationship with clinical outcome for lung stereotactic body radiotherapy (SBRT) delivered via online image guidance. Radiother Oncol, 2014. 110(3): p. 499-504. 55. Koshy, M., et al., Increasing radiation therapy dose is associated with improved survival in patients undergoing stereotactic body radiation therapy for stage I non-small-cell lung cancer. Int J Radiat Oncol Biol Phys, 2015. 91(2): p. 344-50. 56. Li, Q., et al., Stereotactic ablative radiotherapy (SABR) using 70 Gy in 10 fractions for non-small cell lung cancer: exploration of clinical indications. Radiother Oncol, 2014. 112(2): p. 256-61. 57. Martin, A. and A. Gaya, Stereotactic Body Radiotherapy: A Review. Clinical Oncology, 2010. 22(3): p. 157-172. 58. Nelson, J.W., et al., Stereotactic Body Radiotherapy for Lesions of the Spine and Paraspinal Regions. Int J Radiat Oncol Biol Phys, 2009. 73(5): p. 1369-1375. 59. Song, C.W., et al., Radiobiological basis of SBRT and SRS. Int J Clin Oncol, 2014. 19(4): p. 570-8. 60. Soldà, F., et al., Stereotactic radiotherapy (SABR) for the treatment of primary non-small cell lung cancer; Systematic review and comparison with a surgical cohort. Radiotherapy and Oncology, 2013. 109(1): p. 1-7. 61. Lee, W.-Y., et al., Outcomes and cost-effectiveness of gamma knife radiosurgery and whole brain radiotherapy for multiple metastatic brain tumors. Journal of Clinical Neuroscience, 2009. 16(5): p. 630-634. 62. Simonová, G., et al., Fractionated stereotactic radiotherapy with the Leksell Gamma Knife: feasibility study. Radiother. Oncol., 1995. 37(2): p. 108-116. 63. Paddick, I., A simple scoring ratio to index the conformity of radiosurgical treatment plans. J Neurosurg, 2000. 93(supplement 3): p. 219-222. 64. Riet, A.v.t., et al., A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate. Int J Radiat Oncol Biol Phys, 1997. 37(3): p. 731-736. 65. Lomax, N.J. and S.G. Scheib, Quantifying the degree of conformity in radiosurgery treatment planning. Int J Radiat Oncol Biol Phys, 2003. 55(5): p. 1409-1419. 66. Feuvret, L., et al., Conformity index: A review. Int J Radiat Oncol Biol Phys, 2006. 64(2): p. 333-342. 67. Shaw, E., et al., Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines. Int J Radiat Oncol Biol Phys, 1993. 27(5): p. 1231-9. 68. Knöös, T., I. Kristensen, and P. Nilsson, Volumetric and dosimetric evaluation of radiation treatment plans: radiation conformity index. International Journal of Radiation Oncology*Biology*Physics, 1998. 42(5): p. 1169-1176. 69. Paddick, I. and B. Lippitz, A simple dose gradient measurement tool to complement the conformity index. J Neurosurg, 2006. 105 Suppl: p. 194-201. 70. Massager, N., et al., Dosimetric and Clinical Analysis of Spatial Distribution of the Radiation Dose in Gamma Knife Radiosurgery for Vestibular Schwannoma. Int J Radiat Oncol Biol Phys, 2011. 81(4): p. e511-e518. 71. Balagamwala, E.H., et al., The Importance of the Conformality, Heterogeneity, and Gradient Indices in Evaluating Gamma Knife Radiosurgery Treatment Plans for Intracranial Meningiomas. Int J Radiat Oncol Biol Phys, 2012. 83(5): p. 1406-1413. 72. Reiner, B., et al., In Regard to Balagamwala et al. Int J Radiat Oncol Biol Phys, 2013. 85(5): p. 1154-1155. 73. Shehata, M.K., et al., Stereotatic radiosurgery of 468 brain metastases < or =2 cm: implications for SRS dose and whole brain radiation therapy. Int J Radiat Oncol Biol Phys, 2004. 59(1): p. 87-93. 74. Hazard, L.J., R.L. Jensen, and D.C. Shrieve, Role of stereotactic radiosurgery in the treatment of brain metastases. Am J Clin Oncol, 2005. 28(4): p. 403-10. 75. Hasegawa, T., et al., Long-term outcomes of Gamma Knife surgery for cavernous sinus meningioma. J Neurosurg, 2007. 107(4): p. 745-51. 76. Liscak, R., et al., Gamma knife radiosurgery of meningiomas in the cavernous sinus region. Acta Neurochir (Wien), 1999. 141(5): p. 473-80. 77. Pollock, B.E. and S.L. Stafford, Results of stereotactic radiosurgery for patients with imaging defined cavernous sinus meningiomas. Int J Radiat Oncol Biol Phys, 2005. 62(5): p. 1427-31. 78. Kondziolka, D., et al., Stereotactic radiosurgery for convexity meningiomas. J Neurosurg, 2009. 111(3): p. 458-63. 79. Ganz, J.C., W.A. Reda, and K. Abdelkarim, Gamma Knife surgery of large meningiomas: early response to treatment. Acta Neurochir (Wien), 2009. 151(1): p. 1-8. 80. Flannery, T.J., et al., Long-term control of petroclival meningiomas through radiosurgery. J Neurosurg, 2010. 112(5): p. 957-64. 81. Flickinger, J.C., et al., Evolution in technique for vestibular schwannoma radiosurgery and effect on outcome. Int J Radiat Oncol Biol Phys, 1996. 36(2): p. 275-280. 82. Niranjan, A., et al., Dose reduction improves hearing preservation rates after intracanalicular acoustic tumor radiosurgery. Neurosurgery, 1999. 45(4): p. 753-62; discussion 762-5. 83. Regis, J., et al., Radiosurgery: operative technique, pitfalls and tips. Prog Neurol Surg, 2008. 21: p. 54-64. 84. Rogers, C.L., et al., Gamma knife radiosurgery for trigeminal neuralgia: the initial experience of The Barrow Neurological Institute. Int J Radiat Oncol Biol Phys, 2000. 47(4): p. 1013-9. 85. Kondziolka, D., et al., Gamma Knife stereotactic radiosurgery for idiopathic trigeminal neuralgia. J Neurosurg, 2010. 112(4): p. 758-65. 86. Flickinger, J.C., et al., Does increased nerve length within the treatment volume improve trigeminal neuralgia radiosurgery? a prospective double-blind, randomized study. Int J Radiat Oncol Biol Phys, 2001. 51(2): p. 449-454. 87. Jeremy, G., Gamma Knife Neurosurgery. SpringerWienNewYork, 2011: p. 321-322. 88. Yamamoto, Y., et al., Interim report on the radiosurgical treatment of cerebral arteriovenous malformations. The influence of size, dose, time, and technical factors on obliteration rate. J Neurosurg, 1995. 83(5): p. 832-7. 89. Hasegawa, T., et al., Long-term results after stereotactic radiosurgery for patients with cavernous malformations. Neurosurgery, 2002. 50(6): p. 1190-7; discussion 1197-8. 90. Izawa, M., et al., Long-term complications after gamma knife surgery for arteriovenous malformations. J Neurosurg, 2005. 102 Suppl: p. 34-7. 91. Spatola, G., et al., Results of Gamma Knife anterior capsulotomy for refractory obsessive-compulsive disorder: results in a series of 10 consecutive patients. J Neurosurg, 2018: p. 1-8. 92. Ma, L., et al., Whole-procedural Radiological Accuracy for Delivering Multi-session Gamma Knife Radiosurgery With a Relocatable Frame System. Technology in Cancer Research and Treatment, 2013. 93. Bhatnagar, J.P., et al., First year experience with newly developed Leksell Gamma Knife Perfexion. J Med Phys, 2009. 34(3): p. 141-8. 94. Ruschin, M., et al., Investigation of intracranial peripheral dose arising from the treatment of large lesions with Leksell GammaKnife Perfexion. Medical Physics, 2009. 36(6): p. 2069-2073. 95. Sayer, F.T., et al., Initial Experience with the eXtend System: A Relocatable Frame System for Multiple-Session Gamma Knife Radiosurgery. World Neurosurgery, 2011. 75(5-6): p. 665-672. 96. Lindquist, C. and I. Paddick, The Leksell Gamma Knife Perfexion and comparisons with its predecessors. Neurosurgery, 2007. 61(3 Suppl): p. 130-40; discussion 140-1. 97. Jaffray, D.A., et al., Flat-panel cone-beam computed tomography for image-guided radiation therapy. International Journal of Radiation Oncology*Biology*Physics, 2002. 53(5): p. 1337-1349. 98. Lutz, W., K. Winston, and N. Maleki, A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys, 1988. 14(2): p. 373-81. 99. Ruschin, M., et al., Performance of a Novel Repositioning Head Frame for Gamma Knife Perfexion and Image-Guided Linac-Based Intracranial Stereotactic Radiotherapy. Int J Radiat Oncol Biol Phys, 2010. 78(1): p. 306-313. 100. Reiner, B., G. Wright, and P. Bownes, Commissioning of the Extend™ system for Gamma Knife®, in IPEM. 2011: London. 101. van Herk, M., et al., The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys, 2000. 47(4): p. 1121-1135. 102. McKenzie, A., M. van Herk, and B. Mijnheer, Margins for geometric uncertainty around organs at risk in radiotherapy. Radiother. Oncol., 2002. 62(3): p. 299-307. 103. van Herk, M., P. Remeijer, and J.V. Lebesque, Inclusion of geometric uncertainties in treatment plan evaluation. Int J Radiat Oncol Biol Phys, 2002. 52(5): p. 1407-1422. 104. Stroom, J.C., et al., Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. International Journal of Radiation Oncology*Biology*Physics, 1999. 43(4): p. 905-919. 105. Stroom, J.C. and B.J.M. Heijmen, Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report. Radiotherapy and Oncology, 2002. 64(1): p. 75-83. 106. Bethesda, M., ICRU Report 50. Prescribing, Recording, and Reporting Photon Beam Therapy. . International Commission on Radiation Units and Measurements, 1993. 107. Bethesda, M., ICRU Report 62. Prescribing, Recording, and Reporting Photon Beam Therapy (Supplement to ICRU Report 50). International Commission on Radiation Units and Measurements, , 1999. 108. ICRU Report 29. Dose Specification for Reporting External Beam Therapy with Photons and Electrons. 1978. 109. Measurements, I.I.C.o.R.U.a., Prescribing, recording, and reporting photon-beam intensity-modulated radiation therapy (IMRT). ICRU Report 83. J ICRU, 2010. 10: p. 1-106. 110. Torrens, M., et al., THE STANDARDISATION OF TERMINOLOGY IN RADIOSURGERY: Report from the Standardization Committee of the International Leksell Gamma Knife Society (DRAFT DOCUMENT [3.3] FOR CIRCULATION TO LGKS MEMBERS), 2012. 111. Torrens, M., et al., Standardization of terminology in stereotactic radiosurgery: Report from the Standardization Committee of the International Leksell Gamma Knife Society: special topic. J Neurosurg., 2014. Suppl 121: p. 2-15. 112. Regine, W.F., et al., Neurocognitive outcome in brain metastases patients treated with accelerated-fractionation vs. accelerated-hyperfractionated radiotherapy: an analysis from Radiation Therapy Oncology Group Study 91-04. Int J Radiat Oncol Biol Phys, 2001. 51(3): p. 711-717. 113. Korytko, T., et al., 12 Gy gamma knife radiosurgical volume is a predictor for radiation necrosis in non-AVM intracranial tumors. Int J Radiat Oncol Biol Phys, 2006. 64(2): p. 419-424. 114. Lyman, J.T., Complication Probability as Assessed from Dose-Volume Histograms. Radiation Research, 1985. 104(2): p. S13-S19. 115. Burman, C., et al., Fitting of normal tissue tolerance data to an analytic function Int J Radiat Oncol Biol Phys, 1991. 21(1): p. 123-135. 116. Bentzen, S.M., et al., Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): An Introduction to the Scientific Issues. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S3-S9. 117. Lyman, J.T., Normal tissue complication probabilities: Variable dose per fraction. Int J Radiat Oncol Biol Phys, 1992. 22(2): p. 247-250. 118. Emami, B., et al., Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys, 1991. 21(1): p. 109-122. 119. Spring, E. and P. Holmberg, Evaluation of experimental irradiation fractionation with the single-hit, multi-target model. Acta Radiol Ther Phys Biol, 1968. 7(4): p. 297-306. 120. Elkind, M. and G. Whitmore, The radiobiology of cultured mammalian cells. Gordon & Breach, 1967. New York. 121. Lea, D.E., R.B. Haines, and E. Bretscher, The bactericidal action of X-rays, neutrons and radioactive radiations. J Hyg (Lond), 1941. 41(1): p. 1-16. 122. Lea, D.E. and C.A. Coulson, The distribution of the numbers of mutants in bacterial populations. J Genet, 1949. 49(3): p. 264-85. 123. Nomiya, T., Discussions on target theory: past and present. J Radiat Res, 2013. 54(6): p. 1161-3. 124. Brenner, D.J., The Linear-Quadratic Model Is an Appropriate Methodology for Determining Isoeffective Doses at Large Doses Per Fraction. Seminars in Radiation Oncology, 2008. 18(4): p. 234-239. 125. Kirkpatrick, J.P., J.J. Meyer, and L.B. Marks, The Linear-Quadratic Model Is Inappropriate to Model High Dose per Fraction Effects in Radiosurgery. Seminars in Radiation Oncology, 2008. 18(4): p. 240-243. 126. Courdi, A., High doses per fraction and the linear-quadratic model. Radiother. Oncol., 2010. 94(1): p. 121-122. 127. Hoban, P.W., L.C. Jones, and B.G. Clark, Modeling late effects in hypofractionated stereotactic radiotherapy. Int J Radiat Oncol Biol Phys, 1999. 43(1): p. 199-210. 128. Iwata, H., et al., Estimation of Errors Associated With Use of Linear-Quadratic Formalism for Evaluation of Biologic Equivalence Between Single and Hypofractionated Radiation Doses: An In Vitro Study. Int J Radiat Oncol Biol Phys, 2009. 75(2): p. 482-488. 129. Carlson, D.J., et al., Hypofractionation Results in Reduced Tumor Cell Kill Compared to Conventional Fractionation for Tumors With Regions of Hypoxia. Int J Radiat Oncol Biol Phys, 2011. 79(4): p. 1188-1195. 130. Jones, B., et al., Biological equivalent dose assessment of the consequences of hypofractionated radiotherapy. Int J Radiat Oncol Biol Phys, 2000. 47(5): p. 1379-1384. 131. Park, C., et al., Universal Survival Curve and Single Fraction Equivalent Dose: Useful Tools in Understanding Potency of Ablative Radiotherapy. Int J Radiat Oncol Biol Phys, 2008. 70(3): p. 847-852. 132. Clark, B.G., et al., The integral biologically effective dose to predict brain stem toxicity of hypofractionated stereotactic radiotherapy. Int J Radiat Oncol Biol Phys, 1998. 40(3): p. 667-675. 133. Kong, C., et al., A new index comparable to BED for evaluating the biological efficacy of hypofractionated radiotherapy schemes on early stage non-small cell lung cancer: Analysis of data from the literature. Lung Cancer, 2014. 84(1): p. 7-12. 134. Voyant, C., et al., Biological effects and equivalent doses in radiotherapy: A software solution. Reports of Practical Oncology & Radiotherapy, 2014. 19(1): p. 47-55. 135. Fleming, C., et al., A Method for the Prediction of Late Organ-at-Risk Toxicity After Radiotherapy of the Prostate Using Equivalent Uniform Dose. International Journal of Radiation Oncology*Biology*Physics, 2011. 80(2): p. 608-613. 136. Liu, F., et al., Modeling Regional Sensitivity of Radiation Pneumonitis using Multi-institutional EUD Atlases from Phase I Dose Escalation Protocols for Non-small Cell Lung Cancer. Int J Radiat Oncol Biol Phys, 2010. 78(3, Supplement 1): p. S46-S46. 137. Bentzen, S.M., et al., Biomarkers and Surrogate Endpoints for Normal-Tissue Effects of Radiation Therapy: The Importance of Dose-Volume Effects. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S145-S150. 138. Marks, L.B., R.K. Ten Haken, and M.K. Martel, Guest Editor's Introduction to QUANTEC: A Users Guide. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S1-S2. 139. Lawrence, Y.R., et al., Radiation Dose-Volume Effects in the Brain. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S20-S27. 140. Mayo, C., E. Yorke, and T.E. Merchant, Radiation Associated Brainstem Injury. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S36-S41. 141. Zaider, M. and H.I. Amols, A little to a lot or a lot to a little: is NTCP always minimized in multiport therapy? Int J Radiat Oncol Biol Phys, 1998. 41(4): p. 945-950. 142. Peng, L., et al., Updated risk models demonstrate low risk of symptomatic radionecrosis following stereotactic radiosurgery for brain metastases. Surg Neurol Int, 2019. 10: p. 32. 143. Laura Licon, A., et al., A quantitative measure for radiation treatment plan quality. J buon, 2018. 23(5): p. 1460-1466. 144. Beaton, L., et al., Cardiac death after breast radiotherapy and the QUANTEC cardiac guidelines. Clin Transl Radiat Oncol, 2019. 19: p. 39-45. 145. Yen, C.-P. and L. Steiner, Gamma Knife Surgery for Brainstem Arteriovenous Malformations. World Neurosurgery, 2011. 76(1–2): p. 87-95. 146. Jung, E.W., et al., Gamma Knife radiosurgery in the management of brainstem metastases. Clinical Neurology and Neurosurgery, 2013. 115(10): p. 2023-2028. 147. Ma, L., et al., Apparatus dependence of normal brain tissue dose in stereotactic radiosurgery for multiple brain metastases. Journal of Neurosurgery, 2011. 114(6): p. 1580-1584. 148. Park, S.-H., et al., Gamma knife radiosurgery for multiple brain metastases from lung cancer. Journal of Clinical Neuroscience, 2009. 16(5): p. 626-629. 149. Gevaert, T., et al., Dosimetric comparison of different treatment modalities for stereotactic radiosurgery of arteriovenous malformations and acoustic neuromas. Radiother. Oncol., 2013. 106(0): p. 192-197. 150. Al-Shamy, G. and R. Sawaya, Management of brain metastases: the indispensable role of surgery. J Neurooncol, 2009. 92((3)): p. 275-82. 151. Feuvret, L., et al., Stereotactic radiotherapy for large solitary brain metastases. Cancer/Radiothérapie, 2014. 18(2): p. 97-106. 152. Märtens, B., et al., Hypofractionated stereotactic radiotherapy of limited brain metastases: a single-centre individualized treatment approach. BMC Cancer., 2012. 12. 153. Mehta, M., et al., A cost-effectiveness and cost-utility analysis of radiosurgery vs. resection for single-brain metastases. Int J Radiat Oncol Biol Phys, 1997. 39(2): p. 445-454. 154. Yuan, J., et al., Hypofractionation Regimens for Stereotactic Radiotherapy for Large Brain Tumors. Int J Radiat Oncol Biol Phys, 2008. 72(2): p. 390-397. 155. Ganz, J.C., et al., Protection of the anterior visual pathways during gamma knife treatment of meningiomas. British Journal of Neurosurgery, 2010. 24(3): p. 233-243. 156. Kim, Y.-J., et al., Single-Dose Versus Fractionated Stereotactic Radiotherapy for Brain Metastases. Int J Radiat Oncol Biol Phys, 2011. 81(2): p. 483-489. 157. Tuniz, F., et al., Multisession cyberknife stereotactic radiosurgery of large, benign cranial base tumors: preliminary study. Neurosurgery, 2009. 65(5): p. 898-907. 158. Schlesinger, D., et al., Interfraction and intrafraction performance of the Gamma Knife Extend system for patient positioning and immobilization. J Neurosurg. , 2012. 117(Suppl:): p. 217-24. 159. Ma, L., et al., Impact of Millimeter-Level Margins on Peripheral Normal Brain Sparing for Gamma Knife Radiosurgery. Int J Radiat Oncol Biol Phys, 2014. 89(1): p. 206-213. 160. Devriendt, D., et al., Five-fraction Gamma Knife radiosurgery using the Extend relocatable system for benign neoplasms close to optic pathways. Practical Radiation Oncology, 2015(0). 161. Goh, A.S.C., et al., Benign Orbital Apex Tumors Treated with Multisession Gamma Knife Radiosurgery. Ophthalmology, 2013. 120(3): p. 635-641. 162. Kim, M.-S., et al., Gamma knife radiosurgery for orbital tumors. Clinical Neurology and Neurosurgery, 2008. 110(10): p. 1003-1007. 163. Nguyen, J.H., et al., Multisession Gamma Knife Radiosurgery: A Preliminary Experience with a Noninvasive, Relocatable Frame. World Neurosurgery, 2014. 82(6): p. 1256-1263. 164. Gevaert, T., et al., Setup Accuracy of the Novalis ExacTrac 6DOF System for Frameless Radiosurgery. International Journal of Radiation Oncology*Biology*Physics, 2012. 82(5): p. 1627-1635. 165. Murphy, M.J., Intrafraction Geometric Uncertainties in Frameless Image-Guided Radiosurgery. Int J Radiat Oncol Biol Phys, 2009. 73(5): p. 1364-1368. 166. Murphy, M.J., et al., Patterns of patient movement during frameless image-guided radiosurgery. Int J Radiat Oncol Biol Phys, 2003. 55(5): p. 1400-1408. 167. Masi, L., et al., Cone Beam CT Image Guidance for Intracranial Stereotactic Treatments: Comparison With a Frame Guided Set-Up. Int J Radiat Oncol Biol Phys, 2008. 71(3): p. 926-933. 168. Wangerid, T., et al., Implication of using MRI co-registered with CT in Leksell Gamma Knife® dose planning for patients with vestibular schwannoma. Clinical Neurology and Neurosurgery, 2015. 138: p. 10-15. 169. Shaw, E., et al., Single dose radiosurgical treatment of recurrent previously irradiated primary brain tumors and brain metastases: final report of RTOG protocol 90-05. Int J Radiat Oncol Biol Phys, 2000. 47(2): p. 291-8. 170. Lee, C.C., et al., Large intracranial metastatic tumors treated by Gamma Knife surgery: outcomes and prognostic factors. J Neurosurg, 2014. 120(1): p. 52-9. 171. Marks, L.B., et al., Use of Normal Tissue Complication Probability Models in the Clinic. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S10-S19. 172. Mayo, C., et al., Radiation Dose-Volume Effects of Optic Nerves and Chiasm. Int J Radiat Oncol Biol Phys, 2010. 76(3, Supplement 1): p. S28-S35. 173. Choi, C.Y.H., et al., Stereotactic Radiosurgery of the Postoperative Resection Cavity for Brain Metastases: Prospective Evaluation of Target Margin on Tumor Control. Int J Radiat Oncol Biol Phys, 2012. 84(2): p. 336-342. 174. Meyer, J., et al., Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table. Int J Radiat Oncol Biol Phys, 2007. 67(4): p. 1220-1228. 175. Millar, W.T., et al., The role of the concept of biologically effective dose (BED) in treatment planning in radiosurgery. Physica Medica, 2015. 31(6): p. 627-633. 176. Flickinger, J.C., et al., A multi-institutional analysis of complication outcomes after arteriovenous malformation radiosurgery. Int J Radiat Oncol Biol Phys, 1999. 44(1): p. 67-74. 177. Flickinger, J.C., et al., Development of a model to predict permanent symptomatic postradiosurgery injury for arteriovenous malformation patients. Int J Radiat Oncol Biol Phys, 2000. 46(5): p. 1143-1148. 178. Chin, L., L. Ma, and S. DiBiase, Radiation necrosis following gamma knife surgery: a case-controlled comparison of treatment parameters and long-term clinical follow up. J Neurosurg., 2001. 94(6): p. 899-904. 179. Blonigen, B.J., et al., Irradiated Volume as a Predictor of Brain Radionecrosis After Linear Accelerator Stereotactic Radiosurgery. Int J Radiat Oncol Biol Phys, 2010. 77(4): p. 996-1001. 180. Broemme, J., et al., Adjuvant therapy after resection of brain metastases. Frameless image-guided LINAC-based radiosurgery and stereotactic hypofractionated radiotherapy. Strahlenther Onkol, 2013. 189(9): p. 765-70. 181. Davidson, L., et al., Delayed toxicity from gamma knife radiosurgery to lesions in and adjacent to the brainstem. Journal of Clinical Neuroscience, 2009. 16(9): p. 1139-1147. 182. Johnson, M.D., et al., Analysis of Risk Factors for Development of Radiation Necrosis Following Gamma Knife Radiosurgery for Brain Metastases. International Journal of Radiation Oncology*Biology*Physics, 2013. 87(2, Supplement): p. S279-S280. 183. Kondziolka, D., et al., Histological effects of trigeminal nerve radiosurgery in a primate model: implications for trigeminal neuralgia radiosurgery. Neurosurgery, 2000. 46(4): p. 971-6; discussion 976-7. 184. Sheehan, J., et al., Gamma knife surgery for trigeminal schwannoma. J Neurosurg, 2007. 106(5): p. 839-45. 185. Wright, G., et al., Validity of the use of nose tip motion as a surrogate for intracranial motion in mask-fixated frameless Gamma Knife® Icon™ therapy. Journal of Radiosurgery & SBRT 2017. 4(4): p. 289-301. 186. Fowler, J.F., The linear-quadratic formula and progress in fractionated radiotherapy. Br J Radiol, 1989. 62(740): p. 679-694. 187. Thames, H.D., et al., Time-dose factors in radiotherapy: a review of the human data. Radiother. Oncol., 1990. 19(3): p. 219-235. 188. Bostrom, J.P., et al., Risk-adapted single or fractionated stereotactic high-precision radiotherapy in a pooled series of nonfunctioning pituitary adenomas: high local control and low toxicity. Strahlenther Onkol, 2014. 190(12): p. 1095-103. 189. Kuperman, V.Y., Effect of radiation protraction on BED in the case of large fraction dose. Med Phys, 2013. 40(8): p. 081716. 190. Zhao, L., et al., A generalized target theory and its applications. Scientific Reports, 2015. 5: p. 14568. 191. Wright, G., et al., Quantifying and improving the efficiency of Gamma Knife treatment plans for brain metastases: results of a 1-year audit. J Neurosurg, 2014. 121 Suppl: p. 44-50. 192. McMahon, S.J., The linear quadratic model: usage, interpretation and challenges. Physics in Medicine & Biology, 2018. 64(1): p. 01TR01. 193. Wang, J., et al., A Generalized Linear-Quadratic Model for Radiosurgery, Stereotactic Body Radiation Therapy, and High-Dose Rate Brachytherapy. Science translational medicine, 2010. 2: p. 39ra48. 194. Crispin-Ortuzar, M., et al., A radiobiological model of radiotherapy response and its correlation with prognostic imaging variables. Physics in Medicine and Biology, 2017. 62(7): p. 2658-2674. 195. Williams, J.A., Fractionated stereotactic radiotherapy (FSR) for acoustic neuromas. Int J Radiat Oncol Biol Phys, 2000. 48(3, Supplement 1): p. 253-254. 196. Sweeney, R., et al., A simple and non-invasive vacuum mouthpiece-based head fixation system for high precision radiotherapy. Strahlenther Onkol. , 2001. 177(1): p. 43-7. 197. van Santvoort, J., R. Wiggenraad, and P. Bos, Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning. Int J Radiat Oncol Biol Phys, 2008. 72(1): p. 261-267."],"dcterms:accessrights":["public"],"dc:title":["Assessment of the potential and risk of fractionated stereotactic radiosurgery for brain lesions using the Gamma Knife system."],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:34:51Z"}