{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:25610"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:25610","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Automated MRI-based radiotherapy planning for brain tumours","abstract":"Aims: To investigate the clinical feasibility of performing magnetic resonance imaging (MRI)-only radiotherapy planning for patients undergoing treatment for brain tumours. Method: A systematic review was performed of methods which convert MRI scans into synthetic computed tomography (sCT) scans for the purposes of MRI-only radiotherapy planning. The feasibility of using two methods which had been developed at different centres for different anatomical sites, for the production of brain sCTs was assessed. The quality of automatically segmented brain structures generated using one of these techniques was determined. The temporal stability of geometric distortions of four MRI scanners over a year was investigated. A prototype of an MRI and CT compatible anthropomorphic head and neck phantom was developed for the purpose of quality assurance (QA). Results: The review demonstrated that atlas-based and voxel-based techniques were clinically useful methods for sCT generation, with machine learning techniques beginning to develop. An atlas-based technique (previously developed for prostates) and a neural network technique (not previously tested for brains) were found to produce sCTs of acceptable quality for the majority of metrics, after modifications to the clinical MRI scanning protocol were introduced. Dosimetric deviations meant that further optimisation would be required. Larger brain structures were generally well segmented automatically, whilst smaller structures were segmented erratically. The stability of MRI geometric distortions varied between scanners and sequences. A prototype anthropomorphic head and neck phantom was designed and constructed, with future modifications needed in certain areas. Conclusions: The feasibility of producing clinically acceptable brain sCTs along with automatically segmented structures, using models developed at different centres for different anatomical sites, has been shown. The variation in temporal stability of MRI geometric distortions means that careful consideration should be paid to the frequency of distortion QA. An MRI and CT compatible head and neck phantom prototype has been developed.","abstract_html":"Aims: To investigate the clinical feasibility of performing magnetic resonance imaging (MRI)-only radiotherapy planning for patients undergoing treatment for brain tumours. Method: A systematic review was performed of methods which convert MRI scans into synthetic computed tomography (sCT) scans for the purposes of MRI-only radiotherapy planning. The feasibility of using two methods which had been developed at different centres for different anatomical sites, for the production of brain sCTs was assessed. The quality of automatically segmented brain structures generated using one of these techniques was determined. The temporal stability of geometric distortions of four MRI scanners over a year was investigated. A prototype of an MRI and CT compatible anthropomorphic head and neck phantom was developed for the purpose of quality assurance (QA). Results: The review demonstrated that atlas-based and voxel-based techniques were clinically useful methods for sCT generation, with machine learning techniques beginning to develop. An atlas-based technique (previously developed for prostates) and a neural network technique (not previously tested for brains) were found to produce sCTs of acceptable quality for the majority of metrics, after modifications to the clinical MRI scanning protocol were introduced. Dosimetric deviations meant that further optimisation would be required. Larger brain structures were generally well segmented automatically, whilst smaller structures were segmented erratically. The stability of MRI geometric distortions varied between scanners and sequences. A prototype anthropomorphic head and neck phantom was designed and constructed, with future modifications needed in certain areas. Conclusions: The feasibility of producing clinically acceptable brain sCTs along with automatically segmented structures, using models developed at different centres for different anatomical sites, has been shown. The variation in temporal stability of MRI geometric distortions means that careful consideration should be paid to the frequency of distortion QA. An MRI and CT compatible head and neck phantom prototype has been developed.","abstract_has_math":false,"creators":["Johnstone, Emily Rose"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Henry, Ann","Short, Susan","Sebag-Montefiore, David"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-05","date_published":"2019-05","updated_at":"2026-11-18T22:35:36Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/25610/1/Johnstone_ER_Medicine_PhD_2019.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A25610","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Henry, Ann","Short, Susan","Sebag-Montefiore, David"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Leeds Institute of Cancer and Pathology, University of Leeds","John Fisher Foundation"]},{"key":"dc:creator","label":"Author","values":["Johnstone, Emily Rose"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-05"]},{"key":"dc:date.issued","label":"Date","values":["2019-05"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Medicine (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/25610/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. Dirix P, Haustermans K, Vandecaveye V. The value of magnetic resonance imaging for radiotherapy planning. Seminars in Radiation Oncology. 2014;24(3):151-9. doi:10.1016/j.semradonc.2014.02.003. 2. Nyholm T, Jonsson J. Counterpoint: opportunities and challenges of a magnetic resonance imaging only radiotherapy work flow. Seminars in Radiation Oncology. 2014;24(3):175-80. doi:10.1016/j.semradonc.2014.02.005. 3. Edmund JM, Nyholm T. A review of substitute CT generation for MRI-only radiation therapy. Radiation Oncology. 2017;12(1):28. doi:10.1186/s13014-016-0747-y. 4. Liney GP, Moerland MA. Magnetic resonance imaging acquisition techniques for radiotherapy planning. Semin Radiat Oncol. 2014;24(3):160-8. doi:10.1016/j.semradonc.2014.02.014. 5. Ishikura S. Quality assurance of radiotherapy in cancer treatment: toward improvement of patient safety and quality of care. Jpn J Clin Oncol. 2008;38(11):723-9. doi:10.1093/jjco/hyn112. 6. Kutcher GJ, Coia L, Gillin M, et al. Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. Med Phys. 1994;21(4):581-618. doi:10.1118/1.597316. 7. Fraass B, Doppke K, Hunt M, et al. American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning. Med Phys. 1998;25(10):1773-829. doi:10.1118/1.598373. 8. Chang DS, Lasley FD, Das IJ, Mendonca MS, Dynlacht JR. Therapeutic Ratio. Basic Radiotherapy Physics and Biology. Cham: Springer; 2014. 9. Bentzen SM. 3 - Fractionation Effects in Clinical Practice. In: Hoppe RT, Phillips TL, Roach M, editors. Leibel and Phillips Textbook of Radiation Oncology (Third Edition). Philadelphia: W.B. Saunders; 2010. p. 40-54. 10. Stuben G, Thews O, Pottgen C, Stuschke M, Sack H. Tumour oxygenation during fractionated radiotherapy--comparison with size-matched controls. Acta Oncol. 1999;38(2):209-13. 11. Pereira GC, Traughber M, Muzic RF. The Role of Imaging in Radiation Therapy Planning: Past, Present, and Future. BioMed Research International. 2014;2014:9. doi:10.1155/2014/231090. 12. Elert G. Photoelectric effect. In: The Physics Hypertextbook. 2014. http://physics.info/photoelectric/. Accessed 10/03/2019. 13. Hubbell JH. Electron–positron pair production by photons: A historical overview. Radiation Physics and Chemistry. 2006;75(6):614-23. doi:https://doi.org/10.1016/j.radphyschem.2005.10.008. 14. Compton AH. A Quantum Theory of the Scattering of X-rays by Light Elements. Physical Review. 1923;21(5):483-502. doi:10.1103/PhysRev.21.483. 15. Goyal S, Kataria T. Image Guidance in Radiation Therapy: Techniques and Applications. Radiology Research and Practice. 2014;2014:10. doi:10.1155/2014/705604. 16. McRobbie D, Moore E, Graves M, Prince M. MRI from picture to proton. 2nd ed. Cambridge: Cambridge University Press; 2007. 17. Devic S. MRI simulation for radiotherapy treatment planning. Med Phys. 2012;39(11):6701-11. doi:10.1118/1.4758068. 18. Brock KK, Mutic S, McNutt TR, Li H, Kessler ML. Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132. Med Phys. 2017;44(7):e43-e76. doi:10.1002/mp.12256. 19. Lagendijk JJ, Raaymakers BW, Raaijmakers AJ, et al. MRI/linac integration. Radiother Oncol. 2008;86(1):25-9. doi:10.1016/j.radonc.2007.10.034. 20. Kupelian P, Sonke J-J. Magnetic Resonance Guided Adaptive Radiotherapy: A Solution to the Future. Seminars in Radiation Oncology. 2014;24(3):227-32. doi:10.1016/j.semradonc.2014.02.013. 21. Schmidt M, A. , Payne G, S. . Radiotherapy planning using MRI. Phys Med Biol. 2015;60(22):R323. doi:10.1088/0031-9155/60/22/R323. 22. Creak AL, Tree A, Saran F. Radiotherapy planning in high-grade gliomas: a survey of current UK practice. Clin Oncol (R Coll Radiol). 2011;23(3):189-98. doi:10.1016/j.clon.2010.11.003. 23. Hanks G, Chavaudra J, Dobbs J, et al. Report 50. Journal of the International Commission on Radiation Units and Measurements. 2016;os26(1). doi:10.1093/jicru/os26.1.Report50. 24. Aoyama H, Shirato H, Nishioka T, et al. Magnetic resonance imaging system for three-dimensional conformal radiotherapy and its impact on gross tumor volume delineation of central nervous system tumors. International Journal of Radiation Oncology*Biology*Physics. 2001;50(3):821-7. doi:https://doi.org/10.1016/S0360-3016(01)01598-X. 25. Stejskal EO, Tanner JE. Spin Diffusion Measurements: Spin Echoes in the Presence of a Time‐Dependent Field Gradient. The Journal of Chemical Physics. 1965;42(1):288-92. doi:10.1063/1.1695690. 26. Pantelis E, Papadakis N, Verigos K, et al. Integration of functional MRI and white matter tractography in stereotactic radiosurgery clinical practice. Int J Radiat Oncol Biol Phys. 2010;78(1):257-67. doi:10.1016/j.ijrobp.2009.10.064. 27. Demol B, Boydev C, Korhonen J, Reynaert N. Dosimetric characterization of MRI-only treatment planning for brain tumors in atlas-based pseudo-CT images generated from standard T1-weighted MR images. Med Phys. 2016;43(12):6557. doi:10.1118/1.4967480. 28. Nyholm T, Nyberg M, Karlsson MG, Karlsson M. Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments. Radiation Oncology. 2009;4(1):1-9. doi:10.1186/1748-717x-4-54. 29. Andreasen D, Van Leemput K, Hansen RH, Andersen JAL, Edmund JM. Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain. Med Phys. 2015;42(4):1596-605. doi:http://dx.doi.org/10.1118/1.4914158. 30. Ulin K, Urie MM, Cherlow JM. Results of a multi-institutional benchmark test for cranial CT/MR image registration. Int J Radiat Oncol Biol Phys. 2010;77(5):1584-9. doi:10.1016/j.ijrobp.2009.10.017. 31. Lagendijk JJ, Raaymakers BW, Vulpen M. The magnetic resonance imaging-linac system. Semin Radiat Oncol. 2014;24. doi:10.1016/j.semradonc.2014.02.009. 32. Hanson LG. Is quantum mechanics necessary for understanding magnetic resonance? Concepts in Magnetic Resonance Part A. 2008;32A(5):329-40. doi:10.1002/cmr.a.20123. 33. Elster A. Questions and Answers in MRI 2019. Available from: http://mriquestions.com/. Date accessed: 08/11/2019. 34. Bloch F. Nuclear Induction. Physical Review. 1946;70(7-8):460-74. doi:10.1103/PhysRev.70.460. 35. Westbrook C, Kaut Roth C, Talbot J. MRI in practice. 4th ed. Chichester, UK: Wiley-Blackwell; 2011. 36. Liney G. MRI in Clinical Practice. 1st ed. London, UK: Spinger-Verlag; 2006. 37. Karlsson M, Karlsson MG, Nyholm T, Amies C, Zackrisson B. Dedicated magnetic resonance imaging in the radiotherapy clinic. Int J Radiat Oncol Biol Phys. 2009;74. doi:10.1016/j.ijrobp.2009.01.065. 38. Sprawls P. Magnetic Resonance Imaging: Principles, Methods, and Techniques: Medical Physics Publishing; 2000. 39. Low DA, Harms WB, Mutic S, Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys. 1998;25(5):656-61. doi:10.1118/1.598248. 40. Torfeh T, Hammoud R, McGarry M, Al-Hammadi N, Perkins G. Development and validation of a novel large field of view phantom and a software module for the quality assurance of geometric distortion in magnetic resonance imaging. Magnetic Resonance Imaging. 2015;33(7):939-49. doi:https://doi.org/10.1016/j.mri.2015.04.003. 41. Schad L, Lott S, Schmitt F, Sturm V, Lorenz WJ. Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy. J Comput Assist Tomogr. 1987;11(3):499-505. 42. Schad LR, Ehricke H-H, Wowra B, et al. Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformations. Magnetic Resonance Imaging. 1992;10(4):609-21. doi:https://doi.org/10.1016/0730-725X(92)90012-O. 43. Kawanaka A, Takagi M. Estimation of static magnetic field and gradient fields from NMR image. Journal of Physics E: Scientific Instruments. 1986;19(10):871. 44. Wang D, Strugnell W, Cowin G, Doddrell DM, Slaughter R. Geometric distortion in clinical MRI systems: part I: evaluation using a 3D phantom. Magnetic Resonance Imaging. 2004;22(9):1211-21. doi:https://doi.org/10.1016/j.mri.2004.08.012. 45. Wang D, Doddrell DM, Cowin G. A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging. Magnetic Resonance Imaging. 2004;22(4):529-42. doi:https://doi.org/10.1016/j.mri.2004.01.008. 46. Weygand J, Fuller CD, Ibbott GS, et al. Spatial precision in magnetic resonance imaging–guided radiation therapy: the role of geometric distortion. International Journal of Radiation Oncology*Biology*Physics. 2016;95(4):1304-16. doi:https://doi.org/10.1016/j.ijrobp.2016.02.059. 47. Janke A, Zhao H, Cowin GJ, Galloway GJ, Doddrell DM. Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images. Magnetic Resonance in Medicine. 2004;52(1):115-22. doi:10.1002/mrm.20122. 48. Bhagwandien R, Moerland MA, Bakker CJG, Beersma R, Lagendijk JJW. Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D. Magnetic Resonance Imaging. 1994;12(1):101-7. doi:https://doi.org/10.1016/0730-725X(94)92357-4. 49. Nieder C, Grosu AL, Gaspar LE. Stereotactic radiosurgery (SRS) for brain metastases: a systematic review. Radiation Oncology. 2014;9(1):155. doi:10.1186/1748-717x-9-155. 50. Shuryak I, Carlson DJ, Brown JM, Brenner DJ. High-dose and fractionation effects in stereotactic radiation therapy: Analysis of tumor control data from 2965 patients. Radiotherapy and Oncology. 2015;115(3):327-34. doi:https://doi.org/10.1016/j.radonc.2015.05.013. 51. Pappas EP, Alshanqity M, Moutsatsos A, et al. MRI-related geometric distortions in stereotactic radiotherapy treatment planning: evaluation and dosimetric impact. Technol Cancer Res Treat. 2017;16(6):1120-9. doi:10.1177/1533034617735454. 52. Wilson D, Wright, G., Lymer, K., McRobbie, D. Geometric parameters: spatial resolution and distortion. In: McRobbie D, Semple S, editors. IPEM Report 112: Quality control and artefacts in Magnetic Resonance Imaging: Institute of Physics and Engineering in Medicine; 2017. 53. Chen Z, Ma CM, Paskalev K, et al. Investigation of MR image distortion for radiotherapy treatment planning of prostate cancer. Phys Med Biol. 2006;51(6):1393-403. doi:10.1088/0031-9155/51/6/002. 54. Walker A, Liney G, Metcalfe P, Holloway L. MRI distortion: considerations for MRI based radiotherapy treatment planning. Australas Phys Eng Sci Med. 2014;37(1):103-13. doi:10.1007/s13246-014-0252-2. 55. Klein EE, Hanley J, Bayouth J, et al. Task Group 142 report: quality assurance of medical accelerators. Med Phys. 2009;36(9):4197-212. doi:10.1118/1.3190392. 56. Niebuhr NI, Johnen W, Güldaglar T, et al. Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy. Med Phys. 2016;43(2):908-16. doi:10.1118/1.4939874. 57. Menikou G, Dadakova T, Pavlina M, Bock M, Damianou C. MRI compatible head phantom for ultrasound surgery. Ultrasonics. 2015;57:144-52. doi:http://dx.doi.org/10.1016/j.ultras.2014.11.004. 58. Chu KC, Rutt BK. Polyvinyl alcohol cryogel: an ideal phantom material for MR studies of arterial flow and elasticity. Magn Reson Med. 1997;37(2):314-9. 59. Surry KJ, Austin HJ, Fenster A, Peters TM. Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging. Phys Med Biol. 2004;49(24):5529-46. 60. Wardman K, Prestwich RJ, Gooding MJ, Speight RJ. The feasibility of atlas-based automatic segmentation of MRI for H&N radiotherapy planning. J Appl Clin Med Phys. 2016;17(4):146-54. doi:10.1120/jacmp.v17i4.6051. 61. Vinod SK, Jameson MG, Min M, Holloway LC. Uncertainties in volume delineation in radiation oncology: A systematic review and recommendations for future studies. Radiotherapy and Oncology. 2016;121(2):169-79. doi:https://doi.org/10.1016/j.radonc.2016.09.009. 62. Johnstone E, Wyatt JJ, Henry AM, et al. Systematic review of synthetic computed tomography generation methodologies for use in magnetic resonance imaging-only radiation therapy. International Journal of Radiation Oncology • Biology • Physics. 2018;100(1):199-217. doi:10.1016/j.ijrobp.2017.08.043. 63. Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097. doi:10.1371/journal.pmed.1000097. 64. Schad LR, Blüml S, Hawighorst H, Wenz F, Lorenz WJ. Radiosurgical treatment planning of brain metastases based on a fast, three-dimensional MR imaging technique. Magnetic Resonance Imaging. 1994;12(5):811-9. doi:http://dx.doi.org/10.1016/0730-725X(94)92206-3. 65. Ramsey CR, Oliver AL. Magnetic resonance imaging based digitally reconstructed radiographs, virtual simulation, and three-dimensional treatment planning for brain neoplasms. Med Phys. 1998;25(10):1928-34. 66. Prabhakar R, Julka PK, Ganesh T, et al. Feasibility of using MRI alone for 3D radiation treatment planning in brain tumors. Jpn J Clin Oncol. 2007;37. doi:10.1093/jjco/hym050. 67. Wang C, Chao M, Lee L, Xing L. MRI-based treatment planning with electron density information mapped from CT images: a preliminary study. Technol Cancer Res Treat. 2008;7(5):341-8. 68. Weber DC, Wang H, Albrecht S, et al. Open low-field magnetic resonance imaging for target definition, dose calculations and set-up verification during three-dimensional CRT for glioblastoma multiforme. Clinical Oncology (Royal College of Radiologists). 2008;20(2):157-67. 69. Chen L, Price RA, Wang L, et al. MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT. Int J Radiat Oncol Biol Phys. 2004;60. doi:10.1016/j.ijrobp.2004.05.068. 70. Chen L, R. A. Price J, Nguyen TB, et al. Dosimetric evaluation of MRI-based treatment planning for prostate cancer. Phys Med Biol. 2004;49(22):5157. 71. Eilertsen K, Nilsen Tor Arne Vestad L, Geier O, Skretting A. A simulation of MRI based dose calculations on the basis of radiotherapy planning CT images. Acta Oncologica. 2008;47(7):1294-302. doi:10.1080/02841860802256426. 72. Karotki A, Mah K, Meijer G, Meltsner M. Comparison of bulk electron density and voxel-based electron density treatment planning. Journal of Applied Clinical Medical Physics. 2011;12(4):3522. doi:http://dx.doi.org/10.1120/jacmp.v12i4.3522. 73. Korsholm ME, Waring LW, Edmund JM. A criterion for the reliable use of MRI-only radiotherapy. Radiation Oncology. 2014;9:16. doi:http://dx.doi.org/10.1186/1748-717X-9-16. 74. Chin AL, Lin A, Anamalayil S, Teo BK. Feasibility and limitations of bulk density assignment in MRI for head and neck IMRT treatment planning. J Appl Clin Med Phys. 2014;15(5):4851. doi:10.1120/jacmp.v15i5.4851. 75. Doemer A, Chetty IJ, Glide-Hurst C, et al. Evaluating organ delineation, dose calculation and daily localization in an open-MRI simulation workflow for prostate cancer patients. Radiation Oncology. 2015;10(1):1-9. doi:10.1186/s13014-014-0309-0. 76. Jonsson JH, Karlsson MG, Karlsson M, Nyholm T. Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions. Radiation Oncology. 2010;5:62. doi:http://dx.doi.org/10.1186/1748-717X-5-62. 77. Kristensen BH, Laursen FJ, Logager V, Geertsen PF, Krarup-Hansen A. Dosimetric and geometric evaluation of an open low-field magnetic resonance simulator for radiotherapy treatment planning of brain tumours. Radiotherapy & Oncology. 2008;87(1):100-9. doi:http://dx.doi.org/10.1016/j.radonc.2008.01.014. 78. Lambert J, Greer PB, Menk F, et al. MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning. Radiotherapy & Oncology. 2011;98(3):330-4. doi:http://dx.doi.org/10.1016/j.radonc.2011.01.012. 79. Lee YK, Bollet M, Charles-Edwards G, et al. Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone. Radiotherapy & Oncology. 2003;66(2):203-16. 80. Stanescu T, Hans-Sonke J, Pervez N, Stavrev P, Fallone BG. A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions. Phys Med Biol. 2008;53(13):3579-93. doi:10.1088/0031-9155/53/13/013. 81. Stanescu T, Hans-Sonke J, Stavrev P, Fallone G. 3T MR-based treatment planning for radiotherapy of brain lesions. Radiology and Oncology. 2006;40(2):125-32. 82. Ramsey CR, Arwood D, Scaperoth D, Oliver AL. Clinical application of digitally-reconstructed radiographs generated from magnetic resonance imaging for intracranial lesions. International Journal of Radiation Oncology*Biology*Physics. 1999;45(3):797-802. doi:http://dx.doi.org/10.1016/S0360-3016(99)00173-X. 83. Chen L, Nguyen TB, Jones E, et al. Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy: creation of digitally reconstructed radiographs. Int J Radiat Oncol Biol Phys. 2007;68(3):903-11. 84. Hoogcarspel SJ, Van der Velden JM, Lagendijk JJ, van Vulpen M, Raaymakers BW. The feasibility of utilizing pseudo CT-data for online MRI based treatment plan adaptation for a stereotactic radiotherapy treatment of spinal bone metastases. Phys Med Biol. 2014;59(23):7383-91. doi:10.1088/0031-9155/59/23/7383. 85. Dowling JA, Sun J, Pichler P, et al. Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences. Int J Radiat Oncol Biol Phys. 2015;93(5):1144-53. doi:10.1016/j.ijrobp.2015.08.045. 86. Sjolund J, Forsberg D, Andersson M, Knutsson H. Generating patient specific pseudo-CT of the head from MR using atlas-based regression. Phys Med Biol. 2015;60(2):825-39. doi:10.1088/0031-9155/60/2/825. 87. Greer PB, Dowling JA, Lambert JA, et al. A magnetic resonance imaging-based workflow for planning radiation therapy for prostate cancer. Medical Journal of Australia. 2011;194(4):S24-7. 88. Dowling JA, Lambert J, Parker J, et al. An atlas-based electron density mapping method for magnetic resonance imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy. Int J Radiat Oncol Biol Phys. 2012;83(1):e5-11. doi:http://dx.doi.org/10.1016/j.ijrobp.2011.11.056. 89. Uh J, Merchant TE, Li Y, Li X, Hua C. MRI-based treatment planning with pseudo CT generated through atlas registration. Med Phys. 2014;41(5):051711. doi:http://dx.doi.org/10.1118/1.4873315. 90. Siversson C, Nordström F, Nilsson T, et al. Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm. Med Phys. 2015;42(10):6090-7. doi:http://dx.doi.org/10.1118/1.4931417. 91. Andreasen D, Van Leemput K, Edmund JM. A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis. Med Phys. 2016;43(8):4742-52. doi:10.1118/1.4958676. 92. Zhou W, Bovik AC, Sheikh HR, Simoncelli EP. Image quality assessment: from error visibility to structural similarity. IEEE Transactions on Image Processing. 2004;13(4):600-12. doi:10.1109/TIP.2003.819861. 93. Jonsson JH, Johansson A, Soderstrom K, Asklund T, Nyholm T. Treatment planning of intracranial targets on MRI derived substitute CT data. Radiotherapy & Oncology. 2013;108(1):118-22. doi:http://dx.doi.org/10.1016/j.radonc.2013.04.028. 94. Johansson A, Karlsson M, Yu J, Asklund T, Nyholm T. Voxel-wise uncertainty in CT substitute derived from MRI. Med Phys. 2012;39(6):3283-90. doi:http://dx.doi.org/10.1118/1.4711807. 95. Kapanen M, Tenhunen M. T1/T2 -weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning. Acta Oncologica. 2013;52(3):612-8. doi:http://dx.doi.org/10.3109/0284186X.2012.692883. 96. Korhonen J, Kapanen M, Keyrilainen J, Seppala T, Tenhunen M. A dual model HU conversion from MRI intensity values within and outside of bone segment for MRI-based radiotherapy treatment planning of prostate cancer. Med Phys. 2014;41(1):011704. doi:http://dx.doi.org/10.1118/1.4842575. 97. Korhonen J, Kapanen M, Keyrilainen J, et al. Absorbed doses behind bones with MR image-based dose calculations for radiotherapy treatment planning. Med Phys. 2013;40(1):011701. doi:http://dx.doi.org/10.1118/1.4769407. 98. Korhonen J, Kapanen M, Keyrilainen J, et al. Influence of MRI-based bone outline definition errors on external radiotherapy dose calculation accuracy in heterogeneous pseudo-CT images of prostate cancer patients. Acta Oncol. 2014;53(8):1100-6. doi:10.3109/0284186x.2014.929737. 99. Yu H, Caldwell C, Balogh J, Mah K. Toward magnetic resonance-only simulation: segmentation of bone in MR for radiation therapy verification of the head. Int J Radiat Oncol Biol Phys. 2014;89(3):649-57. doi:10.1016/j.ijrobp.2014.03.028. 100. Kim J, Glide-Hurst C, Doemer A, et al. Implementation of a novel algorithm for generating synthetic CT images from magnetic resonance imaging data sets for prostate cancer radiation therapy. Int J Radiat Oncol Biol Phys. 2015;91(1):39-47. doi:http://dx.doi.org/10.1016/j.ijrobp.2014.09.015. 101. Kim J, Garbarino K, Schultz L, et al. Dosimetric evaluation of synthetic CT relative to bulk density assignment-based magnetic resonance-only approaches for prostate radiotherapy. Radiat Oncol. 2015;10:239. doi:10.1186/s13014-015-0549-7. 102. Korhonen J, Kapanen M, Sonke JJ, et al. Feasibility of MRI-based reference images for image-guided radiotherapy of the pelvis with either cone-beam computed tomography or planar localization images. Acta Oncol. 2015;54(6):889-95. doi:10.3109/0284186x.2014.958197. 103. Koivula L, Wee L, Korhonen J. Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images. Med Phys. 2016;43(8):4634. doi:10.1118/1.4958677. 104. Robson MD, Gatehouse PD, Bydder M, Bydder GM. Magnetic resonance: an introduction to ultrashort TE (UTE) imaging. J Comput Assist Tomogr. 2003;27(6):825-46. 105. Larson PEZ, Han M, Krug R, et al. Ultrashort echo time and zero echo time MRI at 7T. Magma (New York, N.Y.). 2016;29(3):359-70. doi:10.1007/s10334-015-0509-0. 106. Lee H, Zhao X, Song HK, et al. Rapid dual-RF, dual-echo, 3D ultrashort echo time craniofacial imaging: A feasibility study. Magn Reson Med. 2019;81(5):3007-16. doi:10.1002/mrm.27625. 107. Rank CM, Hunemohr N, Nagel AM, et al. MRI-based simulation of treatment plans for ion radiotherapy in the brain region. Radiotherapy & Oncology. 2013;109(3):414-8. doi:http://dx.doi.org/10.1016/j.radonc.2013.10.034. 108. Rank CM, Tremmel C, Hunemohr N, et al. MRI-based treatment plan simulation and adaptation for ion radiotherapy using a classification-based approach. Radiation Oncology. 2013;8:51. doi:http://dx.doi.org/10.1186/1748-717X-8-51. 109. Johansson A, Karlsson M, Nyholm T. CT substitute derived from MRI sequences with ultrashort echo time. Med Phys. 2011;38(5):2708-14. doi:http://dx.doi.org/10.1118/1.3578928. 110. Johansson A, Garpebring A, Karlsson M, Asklund T, Nyholm T. Improved quality of computed tomography substitute derived from magnetic resonance (MR) data by incorporation of spatial information--potential application for MR-only radiotherapy and attenuation correction in positron emission tomography. Acta Oncologica. 2013;52(7):1369-73. doi:http://dx.doi.org/10.3109/0284186X.2013.819119. 111. Johansson A, Garpebring A, Asklund T, Nyholm T. CT substitutes derived from MR images reconstructed with parallel imaging. Med Phys. 2014;41(8):082302. doi:http://dx.doi.org/10.1118/1.4886766. 112. Hsu SH, Cao Y, Huang K, Feng M, Balter JM. Investigation of a method for generating synthetic CT models from MRI scans of the head and neck for radiotherapy. Phys Med Biol. 2013;58. doi:10.1088/0031-9155/58/23/8419. 113. Edmund JM, Kjer HM, Van Leemput K, et al. A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times. Phys Med Biol. 2014;59(23):7501-19. doi:10.1088/0031-9155/59/23/7501. 114. Jonsson JH, Akhtari MM, Karlsson MG, et al. Accuracy of inverse treatment planning on substitute CT images derived from MR data for brain lesions. Radiation Oncology. 2015;10(1):1-7. doi:10.1186/s13014-014-0308-1. 115. Hsu SH, Cao Y, Lawrence TS, et al. Quantitative characterizations of ultrashort echo (UTE) images for supporting air-bone separation in the head. Phys Med Biol. 2015;60(7):2869-80. doi:10.1088/0031-9155/60/7/2869. 116. Paradis E, Cao Y, Lawrence TS, et al. Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy. Int J Radiat Oncol Biol Phys. 2015;93(5):1154-61. doi:10.1016/j.ijrobp.2015.08.049. 117. Zheng W, Kim JP, Kadbi M, et al. Magnetic Resonance-Based Automatic Air Segmentation for Generation of Synthetic Computed Tomography Scans in the Head Region. Int J Radiat Oncol Biol Phys. 2015;93(3):497-506. doi:10.1016/j.ijrobp.2015.07.001. 118. Gutierrez S, Descamps B, Vanhove C. MRI-Only Based Radiotherapy Treatment Planning for the Rat Brain on a Small Animal Radiation Research Platform (SARRP). PLoS One. 2015;10(12):e0143821. doi:10.1371/journal.pone.0143821. 119. Price RG, Kim JP, Zheng W, Chetty IJ, Glide-Hurst C. Image Guided Radiation Therapy Using Synthetic Computed Tomography Images in Brain Cancer. Int J Radiat Oncol Biol Phys. 2016;95(4):1281-9. doi:10.1016/j.ijrobp.2016.03.002. 120. Yang Y, Cao M, Kaprealian T, et al. Accuracy of UTE-MRI-based patient setup for brain cancer radiation therapy. Med Phys. 2016;43(1):262-7. doi:10.1118/1.4938266. 121. Grodzki DM, Jakob PM, Heismann B. Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA). Magn Reson Med. 2012;67(2):510-8. doi:10.1002/mrm.23017. 122. Gudur MS, Hara W, Le QT, et al. A unifying probabilistic Bayesian approach to derive electron density from MRI for radiation therapy treatment planning. Phys Med Biol. 2014;59(21):6595-606. doi:10.1088/0031-9155/59/21/6595. 123. Keereman V, Fierens Y, Broux T, et al. MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences. J Nucl Med. 2010;51(5):812-8. doi:10.2967/jnumed.109.065425. 124. Perkins G. (Personal correspondance). Philips Electronics UK Ltd; 2017. 125. Greer PB. (Personal correspondance). Calvary Mater Newcastle, Newcastle, Australia;2017. 126. Han X. MR-based synthetic CT generation using a deep convolutional neural network method. Med Phys. 2017;44(4):1408-19. doi:10.1002/mp.12155. 127. Largent A, Barateau A, Nunes JC, et al. Pseudo-CT Generation for MRI-Only Radiation Therapy Treatment Planning: Comparison Among Patch-Based, Atlas-Based, and Bulk Density Methods. Int J Radiat Oncol Biol Phys. 2019;103(2):479-90. doi:10.1016/j.ijrobp.2018.10.002. 128. Emami H, Dong M, Nejad-Davarani SP, Glide-Hurst CK. Generating synthetic CTs from magnetic resonance images using generative adversarial networks. Med Phys. 2018. doi:10.1002/mp.13047. 129. Dinkla AM, Wolterink JM, Maspero M, et al. MR-Only Brain Radiation Therapy: Dosimetric Evaluation of Synthetic CTs Generated by a Dilated Convolutional Neural Network. Int J Radiat Oncol Biol Phys. 2018;102(4):801-12. doi:10.1016/j.ijrobp.2018.05.058. 130. Maspero M, Savenije MHF, Dinkla AM, et al. Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy. Phys Med Biol. 2018;63(18):185001. doi:10.1088/1361-6560/aada6d. 131. Fedorov A, Beichel R, Kalpathy-Cramer J, et al. 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging. 2012;30(9):1323-41. doi:10.1016/j.mri.2012.05.001. 132. Eaton J, Bateman D, Hauberg S, Wehbring R. GNU Octave version 4.0.0 manual: a high-level interactive language for numerical computations 2015. Available from: http://www.gnu.org/software/octave/doc/interpreter. 133. Pinter C, Lasso A, Wang A, Jaffray D, Fichtinger G. SlicerRT: radiation therapy research toolkit for 3D Slicer. Med Phys. 2012;39(10):6332-8. doi:10.1118/1.4754659. 134. Aljabar P, Heckemann RA, Hammers A, Hajnal JV, Rueckert D. Multi-atlas based segmentation of brain images: Atlas selection and its effect on accuracy. Neuroimage. 2009;46(3):726-38. doi:https://doi.org/10.1016/j.neuroimage.2009.02.018. 135. Siversson C, Akhondi-Asl A, Bixby S, Kim YJ, Warfield SK. Three-dimensional hip cartilage quality assessment of morphology and dGEMRIC by planar maps and automated segmentation. Osteoarthritis Cartilage. 2014;22(10):1511-5. doi:10.1016/j.joca.2014.08.012. 136. Report 83. Journal of the International Commission on Radiation Units and Measurements. 2010;10(1). doi:10.1093/jicru/10.1.Report83. 137. Kamalian S, Lev MH, Gupta R. Chapter 1 - Computed tomography imaging and angiography – principles. In: Masdeu JC, González RG, editors. Handbook of Clinical Neurology. 135: Elsevier; 2016. p. 3-20. 138. Lustberg T, van Soest J, Gooding M, et al. Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer. Radiother Oncol. 2018;126(2):312-7. doi:10.1016/j.radonc.2017.11.012. 139. Sharp G, Fritscher KD, Pekar V, et al. Vision 20/20: Perspectives on automated image segmentation for radiotherapy. Med Phys. 2016;41(5):050902. doi:10.1118/1.4871620. 140. Bauer S, Wiest R, Nolte LP, Reyes M. A survey of MRI-based medical image analysis for brain tumor studies. Phys Med Biol. 2013;58(13):R97-129. doi:10.1088/0031-9155/58/13/r97. 141. Eekers DBP, in 't Ven L, Roelofs E, et al. The EPTN consensus-based atlas for CT- and MR-based contouring in neuro-oncology. Radiotherapy and Oncology. 2018;128(1):37-43. doi:https://doi.org/10.1016/j.radonc.2017.12.013. 142. Scoccianti S, Detti B, Gadda D, et al. Organs at risk in the brain and their dose-constraints in adults and in children: a radiation oncologist's guide for delineation in everyday practice. Radiother Oncol. 2015;114(2):230-8. doi:10.1016/j.radonc.2015.01.016. 143. Dice LR. Measures of the Amount of Ecologic Association Between Species. Ecology. 1945;26(3):297-302. doi:10.2307/1932409. 144. Chuter R, Prestwich R, Bird D, et al. The use of deformable image registration to integrate diagnostic MRI into the radiotherapy planning pathway for head and neck cancer. Radiotherapy and Oncology. 2017;122(2):229-35. doi:10.1016/j.radonc.2016.07.016. 145. Jena R, Kirkby NF, Burton KE, et al. A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes. Br J Radiol. 2010;83(985):44-51. doi:10.1259/bjr/27674581. 146. Hughes GK, Miszkiel KA. Imaging of the Lacrimal Gland. Seminars in Ultrasound, CT and MRI. 2006;27(6):476-91. doi:https://doi.org/10.1053/j.sult.2006.09.002. 147. Evanson J. Radiology of the Pituitary. South Dartmouth (MA)2016. Available from: https://www.ncbi.nlm.nih.gov/books/NBK279161/. 148. Isambert A, Dhermain F, Bidault F, et al. Evaluation of an atlas-based automatic segmentation software for the delineation of brain organs at risk in a radiation therapy clinical context. Radiotherapy and Oncology. 2008;87(1):93. doi:https://doi.org/10.1016/j.radonc.2007.11.030. 149. Brouwer CL, Steenbakkers RJHM, Bourhis J, et al. CT-based delineation of organs at risk in the head and neck region: DAHANCA, EORTC, GORTEC, HKNPCSG, NCIC CTG, NCRI, NRG Oncology and TROG consensus guidelines. Radiotherapy and Oncology. 2015;117(1):83-90. doi:10.1016/j.radonc.2015.07.041. 150. Price RG, Knight RA, Hwang K-P, et al. Optimization of a novel large field of view distortion phantom for MR-only treatment planning. Journal of Applied Clinical Medical Physics. 2017;18(4):51-61. doi:10.1002/acm2.12090. 151. Walker A, Liney G, Holloway L, et al. Continuous table acquisition MRI for radiotherapy treatment planning: distortion assessment with a new extended 3D volumetric phantom. Med Phys. 2015;42(4):1982-91. doi:10.1118/1.4915920. 152. Torfeh T, Hammoud R, Perkins G, et al. Characterization of 3D geometric distortion of magnetic resonance imaging scanners commissioned for radiation therapy planning. Magnetic Resonance Imaging. 2016;34(5):645-53. doi:https://doi.org/10.1016/j.mri.2016.01.001. 153. Moerland MA. Magnetic resonance imaging in radiotherapy treatment planning: University of Utrecht; 1996. 154. Ahmed M, Schmidt M, Sohaib A, et al. The value of magnetic resonance imaging in target volume delineation of base of tongue tumours – A study using flexible surface coils. Radiotherapy and Oncology. 2010;94(2):161-7. doi:https://doi.org/10.1016/j.radonc.2009.12.021. 155. Mizowaki T, Nagata Y, Okajima K, et al. Reproducibility of geometric distortion in magnetic resonance imaging based on phantom studies. Radiother Oncol. 2000;57(2):237-42. 156. Boas M. Binomial distribution. Mathematical Methods in the Physical Sciences. 2nd ed: John Wiley and sons; 1983. 157. NIST/SEMATECH. Measures of skewness and kurtosis. In: NIST/ SEMATECH e-Handbook of statistical methods. National Institute of Standards and Technology, United States Department of Commerce; 2013. http://www.itl.nist.gov/div898/handbook/eda/section3/eda35b.htm. Accessed 09/03/2018. 158. Paulson ES, Erickson B, Schultz C, Li XA. Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning. Med Phys. 2015;42(1):28-39. doi:10.1118/1.4896096. 159. Mah D, Steckner M, Palacio E, et al. Characteristics and quality assurance of a dedicated open 0.23 T MRI for radiation therapy simulation. Med Phys. 2002;29(11):2541-7. doi:10.1118/1.1513991. 160. Price RG, Kadbi M, Kim J, et al. Technical note: characterization and correction of gradient nonlinearity induced distortion on a 1.0 T open bore MR-SIM. Med Phys. 2015;42(10):5955-60. doi:10.1118/1.4930245. 161. Baldwin LN, Wachowicz K, Thomas SD, Rivest R, Fallone BG. Characterization, prediction, and correction of geometric distortion in 3 T MR images. Med Phys. 2007;34(2):388-99. doi:10.1118/1.2402331. 162. Kapanen M, Collan J, Beule A, et al. Commissioning of MRI-only based treatment planning procedure for external beam radiotherapy of prostate. Magn Reson Med. 2013;70(1):127-35. doi:10.1002/mrm.24459. 163. Damyanovich AZ, Rieker M, Zhang B, Bissonnette JP, Jaffray DA. Design and implementation of a 3D-MR/CT geometric image distortion phantom/analysis system for stereotactic radiosurgery. Phys Med Biol. 2018;63(7):075010. doi:10.1088/1361-6560/aab33e. 164. Chen HH, Boykin RD, Clarke GD, Gao JH, Roby JW, 3rd. Routine testing of magnetic field homogeneity on clinical MRI systems. Med Phys. 2006;33(11):4299-306. doi:10.1118/1.2359229. 165. Schenck JF. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys. 1996;23(6):815-50. doi:10.1118/1.597854. 166. Haidekker MA. Magnetic Resonance Imaging. Medical Imaging Technology. New York: Springer Science & Business Media; 2013. 167. Rasband WS. ImageJ. U. S. National Institutes of Health, Bethesda, Maryland, USA1997-2018. 168. Schneider CA, Rasband WS, Eliceiri KW. NIH Image to ImageJ: 25 years of image analysis. Nature Methods. 2012;9:671. doi:10.1038/nmeth.2089. 169. Leymarie F, Levine MD. Fast raster scan distance propagation on the discrete rectangular lattice. CVGIP: Image Understanding. 1992;55(1):84-94. doi:https://doi.org/10.1016/1049-9660(92)90008-Q. 170. Cancer Research UK. Brain, other CNS and intracranial tumours incidence statistics 2019. Available from: https://www.cancerresearchuk.org/health-professional/cancer-statistics/statistics-by-cancer-type/brain-other-cns-and-intracranial-tumours/incidence#heading-One. Date accessed: 09/02/2019. 171. Gallas RR, Hunemohr N, Runz A, et al. An anthropomorphic multimodality (CT/MRI) head phantom prototype for end-to-end tests in ion radiotherapy. Z Med Phys. 2015;25(4):391-9. doi:10.1016/j.zemedi.2015.05.003. 172. Fortune S, Jansen MA, Anderson T, et al. Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging. Magnetic Resonance Imaging. 2012;30(8):1186-91. doi:https://doi.org/10.1016/j.mri.2012.04.008. 173. Dental treatments: NHS Choices; updated 25/11/2015. Available from: http://www.nhs.uk/Livewell/dentalhealth/Pages/Dentaltreatments.aspx. Date accessed: 14/08/2017. 174. Mail N, Albarakati Y, Ahmad Khan M, et al. The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution. Med Phys. 2013;40(8):081714. doi:10.1118/1.4816307. 175. Allahverdi M, Nisbet A, Thwaites DI. An evaluation of epoxy resin phantom materials for megavoltage photon dosimetry. Physics in Medicine & Biology. 1999;44(5):1125. 176. Messroghli DR, Radjenovic A, Kozerke S, et al. Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magnetic Resonance in Medicine. 2004;52(1):141-6. doi:10.1002/mrm.20110. 177. Formula Saint-Gobain. Crystacal R 2019. Available from: https://www.saintgobainformula.com/product/crystacal-r. Date accessed: 09/02/2019. 178. Formula Saint-Gobain. Dental Plaster 2019. Available from: https://www.saintgobainformula.com/product/dental-plaster. Date accessed: 09/02/2019. 179. Bojorquez JZ, Bricq S, Acquitter C, et al. What are normal relaxation times of tissues at 3 T? Magnetic Resonance Imaging. 2017;35:69-80. doi:https://doi.org/10.1016/j.mri.2016.08.021. 180. Kim S, Lee GH, Lee S, et al. Body fat measurement in computed tomography image. Biomed Sci Instrum. 1999;35:303-8. 181. Yushkevich PA, Piven J, Hazlett HC, et al. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage. 2006;31(3):1116-28. doi:10.1016/j.neuroimage.2006.01.015. 182. Persson E, Gustafsson C, Nordstrom F, et al. MR-OPERA: A Multicenter/Multivendor Validation of Magnetic Resonance Imaging-Only Prostate Treatment Planning Using Synthetic Computed Tomography Images. Int J Radiat Oncol Biol Phys. 2017;99(3):692-700. doi:10.1016/j.ijrobp.2017.06.006. 183. Bridge P, Fielding A, Rowntree P, Pullar A. Intraobserver Variability: Should We Worry? Journal of Medical Imaging and Radiation Sciences. 2016;47(3):217-20. doi:10.1016/j.jmir.2016.06.004."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/25610/1/Johnstone_ER_Medicine_PhD_2019.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Aims: To investigate the clinical feasibility of performing magnetic resonance imaging (MRI)-only radiotherapy planning for patients undergoing treatment for brain tumours. Method: A systematic review was performed of methods which convert MRI scans into synthetic computed tomography (sCT) scans for the purposes of MRI-only radiotherapy planning. The feasibility of using two methods which had been developed at different centres for different anatomical sites, for the production of brain sCTs was assessed. The quality of automatically segmented brain structures generated using one of these techniques was determined. The temporal stability of geometric distortions of four MRI scanners over a year was investigated. A prototype of an MRI and CT compatible anthropomorphic head and neck phantom was developed for the purpose of quality assurance (QA). Results: The review demonstrated that atlas-based and voxel-based techniques were clinically useful methods for sCT generation, with machine learning techniques beginning to develop. An atlas-based technique (previously developed for prostates) and a neural network technique (not previously tested for brains) were found to produce sCTs of acceptable quality for the majority of metrics, after modifications to the clinical MRI scanning protocol were introduced. Dosimetric deviations meant that further optimisation would be required. Larger brain structures were generally well segmented automatically, whilst smaller structures were segmented erratically. The stability of MRI geometric distortions varied between scanners and sequences. A prototype anthropomorphic head and neck phantom was designed and constructed, with future modifications needed in certain areas. Conclusions: The feasibility of producing clinically acceptable brain sCTs along with automatically segmented structures, using models developed at different centres for different anatomical sites, has been shown. The variation in temporal stability of MRI geometric distortions means that careful consideration should be paid to the frequency of distortion QA. An MRI and CT compatible head and neck phantom prototype has been developed."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Automated MRI-based radiotherapy planning for brain tumours"]}]}],"canonical_facts":{"dc:contributor.advisor":["Henry, Ann","Short, Susan","Sebag-Montefiore, David"],"dc:contributor.sponsor":["Leeds Institute of Cancer and Pathology, University of Leeds","John Fisher Foundation"],"dc:creator":["Johnstone, Emily Rose"],"dc:date":["2019-05"],"dc:date.issued":["2019-05"],"dc:description.abstract":["Aims: To investigate the clinical feasibility of performing magnetic resonance imaging (MRI)-only radiotherapy planning for patients undergoing treatment for brain tumours. Method: A systematic review was performed of methods which convert MRI scans into synthetic computed tomography (sCT) scans for the purposes of MRI-only radiotherapy planning. The feasibility of using two methods which had been developed at different centres for different anatomical sites, for the production of brain sCTs was assessed. The quality of automatically segmented brain structures generated using one of these techniques was determined. The temporal stability of geometric distortions of four MRI scanners over a year was investigated. A prototype of an MRI and CT compatible anthropomorphic head and neck phantom was developed for the purpose of quality assurance (QA). Results: The review demonstrated that atlas-based and voxel-based techniques were clinically useful methods for sCT generation, with machine learning techniques beginning to develop. An atlas-based technique (previously developed for prostates) and a neural network technique (not previously tested for brains) were found to produce sCTs of acceptable quality for the majority of metrics, after modifications to the clinical MRI scanning protocol were introduced. Dosimetric deviations meant that further optimisation would be required. Larger brain structures were generally well segmented automatically, whilst smaller structures were segmented erratically. The stability of MRI geometric distortions varied between scanners and sequences. A prototype anthropomorphic head and neck phantom was designed and constructed, with future modifications needed in certain areas. Conclusions: The feasibility of producing clinically acceptable brain sCTs along with automatically segmented structures, using models developed at different centres for different anatomical sites, has been shown. The variation in temporal stability of MRI geometric distortions means that careful consideration should be paid to the frequency of distortion QA. An MRI and CT compatible head and neck phantom prototype has been developed."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/25610/1/Johnstone_ER_Medicine_PhD_2019.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["School of Medicine (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/25610/"],"dc:relation.references":["1. Dirix P, Haustermans K, Vandecaveye V. The value of magnetic resonance imaging for radiotherapy planning. Seminars in Radiation Oncology. 2014;24(3):151-9. doi:10.1016/j.semradonc.2014.02.003. 2. Nyholm T, Jonsson J. Counterpoint: opportunities and challenges of a magnetic resonance imaging only radiotherapy work flow. Seminars in Radiation Oncology. 2014;24(3):175-80. doi:10.1016/j.semradonc.2014.02.005. 3. Edmund JM, Nyholm T. A review of substitute CT generation for MRI-only radiation therapy. Radiation Oncology. 2017;12(1):28. doi:10.1186/s13014-016-0747-y. 4. Liney GP, Moerland MA. Magnetic resonance imaging acquisition techniques for radiotherapy planning. Semin Radiat Oncol. 2014;24(3):160-8. doi:10.1016/j.semradonc.2014.02.014. 5. Ishikura S. Quality assurance of radiotherapy in cancer treatment: toward improvement of patient safety and quality of care. Jpn J Clin Oncol. 2008;38(11):723-9. doi:10.1093/jjco/hyn112. 6. Kutcher GJ, Coia L, Gillin M, et al. Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. Med Phys. 1994;21(4):581-618. doi:10.1118/1.597316. 7. Fraass B, Doppke K, Hunt M, et al. American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning. Med Phys. 1998;25(10):1773-829. doi:10.1118/1.598373. 8. Chang DS, Lasley FD, Das IJ, Mendonca MS, Dynlacht JR. Therapeutic Ratio. Basic Radiotherapy Physics and Biology. Cham: Springer; 2014. 9. Bentzen SM. 3 - Fractionation Effects in Clinical Practice. In: Hoppe RT, Phillips TL, Roach M, editors. Leibel and Phillips Textbook of Radiation Oncology (Third Edition). Philadelphia: W.B. Saunders; 2010. p. 40-54. 10. Stuben G, Thews O, Pottgen C, Stuschke M, Sack H. Tumour oxygenation during fractionated radiotherapy--comparison with size-matched controls. Acta Oncol. 1999;38(2):209-13. 11. Pereira GC, Traughber M, Muzic RF. The Role of Imaging in Radiation Therapy Planning: Past, Present, and Future. BioMed Research International. 2014;2014:9. doi:10.1155/2014/231090. 12. Elert G. Photoelectric effect. In: The Physics Hypertextbook. 2014. http://physics.info/photoelectric/. Accessed 10/03/2019. 13. Hubbell JH. Electron–positron pair production by photons: A historical overview. Radiation Physics and Chemistry. 2006;75(6):614-23. doi:https://doi.org/10.1016/j.radphyschem.2005.10.008. 14. Compton AH. A Quantum Theory of the Scattering of X-rays by Light Elements. Physical Review. 1923;21(5):483-502. doi:10.1103/PhysRev.21.483. 15. Goyal S, Kataria T. Image Guidance in Radiation Therapy: Techniques and Applications. Radiology Research and Practice. 2014;2014:10. doi:10.1155/2014/705604. 16. McRobbie D, Moore E, Graves M, Prince M. MRI from picture to proton. 2nd ed. Cambridge: Cambridge University Press; 2007. 17. Devic S. MRI simulation for radiotherapy treatment planning. Med Phys. 2012;39(11):6701-11. doi:10.1118/1.4758068. 18. Brock KK, Mutic S, McNutt TR, Li H, Kessler ML. Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132. Med Phys. 2017;44(7):e43-e76. doi:10.1002/mp.12256. 19. Lagendijk JJ, Raaymakers BW, Raaijmakers AJ, et al. MRI/linac integration. Radiother Oncol. 2008;86(1):25-9. doi:10.1016/j.radonc.2007.10.034. 20. Kupelian P, Sonke J-J. Magnetic Resonance Guided Adaptive Radiotherapy: A Solution to the Future. Seminars in Radiation Oncology. 2014;24(3):227-32. doi:10.1016/j.semradonc.2014.02.013. 21. Schmidt M, A. , Payne G, S. . Radiotherapy planning using MRI. Phys Med Biol. 2015;60(22):R323. doi:10.1088/0031-9155/60/22/R323. 22. Creak AL, Tree A, Saran F. Radiotherapy planning in high-grade gliomas: a survey of current UK practice. Clin Oncol (R Coll Radiol). 2011;23(3):189-98. doi:10.1016/j.clon.2010.11.003. 23. Hanks G, Chavaudra J, Dobbs J, et al. Report 50. Journal of the International Commission on Radiation Units and Measurements. 2016;os26(1). doi:10.1093/jicru/os26.1.Report50. 24. Aoyama H, Shirato H, Nishioka T, et al. Magnetic resonance imaging system for three-dimensional conformal radiotherapy and its impact on gross tumor volume delineation of central nervous system tumors. International Journal of Radiation Oncology*Biology*Physics. 2001;50(3):821-7. doi:https://doi.org/10.1016/S0360-3016(01)01598-X. 25. Stejskal EO, Tanner JE. Spin Diffusion Measurements: Spin Echoes in the Presence of a Time‐Dependent Field Gradient. The Journal of Chemical Physics. 1965;42(1):288-92. doi:10.1063/1.1695690. 26. Pantelis E, Papadakis N, Verigos K, et al. Integration of functional MRI and white matter tractography in stereotactic radiosurgery clinical practice. Int J Radiat Oncol Biol Phys. 2010;78(1):257-67. doi:10.1016/j.ijrobp.2009.10.064. 27. Demol B, Boydev C, Korhonen J, Reynaert N. Dosimetric characterization of MRI-only treatment planning for brain tumors in atlas-based pseudo-CT images generated from standard T1-weighted MR images. Med Phys. 2016;43(12):6557. doi:10.1118/1.4967480. 28. Nyholm T, Nyberg M, Karlsson MG, Karlsson M. Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments. Radiation Oncology. 2009;4(1):1-9. doi:10.1186/1748-717x-4-54. 29. Andreasen D, Van Leemput K, Hansen RH, Andersen JAL, Edmund JM. Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain. Med Phys. 2015;42(4):1596-605. doi:http://dx.doi.org/10.1118/1.4914158. 30. Ulin K, Urie MM, Cherlow JM. Results of a multi-institutional benchmark test for cranial CT/MR image registration. Int J Radiat Oncol Biol Phys. 2010;77(5):1584-9. doi:10.1016/j.ijrobp.2009.10.017. 31. Lagendijk JJ, Raaymakers BW, Vulpen M. The magnetic resonance imaging-linac system. Semin Radiat Oncol. 2014;24. doi:10.1016/j.semradonc.2014.02.009. 32. Hanson LG. Is quantum mechanics necessary for understanding magnetic resonance? Concepts in Magnetic Resonance Part A. 2008;32A(5):329-40. doi:10.1002/cmr.a.20123. 33. Elster A. Questions and Answers in MRI 2019. Available from: http://mriquestions.com/. Date accessed: 08/11/2019. 34. Bloch F. Nuclear Induction. Physical Review. 1946;70(7-8):460-74. doi:10.1103/PhysRev.70.460. 35. Westbrook C, Kaut Roth C, Talbot J. MRI in practice. 4th ed. Chichester, UK: Wiley-Blackwell; 2011. 36. Liney G. MRI in Clinical Practice. 1st ed. London, UK: Spinger-Verlag; 2006. 37. Karlsson M, Karlsson MG, Nyholm T, Amies C, Zackrisson B. Dedicated magnetic resonance imaging in the radiotherapy clinic. Int J Radiat Oncol Biol Phys. 2009;74. doi:10.1016/j.ijrobp.2009.01.065. 38. Sprawls P. Magnetic Resonance Imaging: Principles, Methods, and Techniques: Medical Physics Publishing; 2000. 39. Low DA, Harms WB, Mutic S, Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys. 1998;25(5):656-61. doi:10.1118/1.598248. 40. Torfeh T, Hammoud R, McGarry M, Al-Hammadi N, Perkins G. Development and validation of a novel large field of view phantom and a software module for the quality assurance of geometric distortion in magnetic resonance imaging. Magnetic Resonance Imaging. 2015;33(7):939-49. doi:https://doi.org/10.1016/j.mri.2015.04.003. 41. Schad L, Lott S, Schmitt F, Sturm V, Lorenz WJ. Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy. J Comput Assist Tomogr. 1987;11(3):499-505. 42. Schad LR, Ehricke H-H, Wowra B, et al. Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformations. Magnetic Resonance Imaging. 1992;10(4):609-21. doi:https://doi.org/10.1016/0730-725X(92)90012-O. 43. Kawanaka A, Takagi M. Estimation of static magnetic field and gradient fields from NMR image. Journal of Physics E: Scientific Instruments. 1986;19(10):871. 44. Wang D, Strugnell W, Cowin G, Doddrell DM, Slaughter R. Geometric distortion in clinical MRI systems: part I: evaluation using a 3D phantom. Magnetic Resonance Imaging. 2004;22(9):1211-21. doi:https://doi.org/10.1016/j.mri.2004.08.012. 45. Wang D, Doddrell DM, Cowin G. A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging. Magnetic Resonance Imaging. 2004;22(4):529-42. doi:https://doi.org/10.1016/j.mri.2004.01.008. 46. Weygand J, Fuller CD, Ibbott GS, et al. Spatial precision in magnetic resonance imaging–guided radiation therapy: the role of geometric distortion. International Journal of Radiation Oncology*Biology*Physics. 2016;95(4):1304-16. doi:https://doi.org/10.1016/j.ijrobp.2016.02.059. 47. Janke A, Zhao H, Cowin GJ, Galloway GJ, Doddrell DM. Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images. Magnetic Resonance in Medicine. 2004;52(1):115-22. doi:10.1002/mrm.20122. 48. Bhagwandien R, Moerland MA, Bakker CJG, Beersma R, Lagendijk JJW. Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D. Magnetic Resonance Imaging. 1994;12(1):101-7. doi:https://doi.org/10.1016/0730-725X(94)92357-4. 49. Nieder C, Grosu AL, Gaspar LE. Stereotactic radiosurgery (SRS) for brain metastases: a systematic review. Radiation Oncology. 2014;9(1):155. doi:10.1186/1748-717x-9-155. 50. Shuryak I, Carlson DJ, Brown JM, Brenner DJ. High-dose and fractionation effects in stereotactic radiation therapy: Analysis of tumor control data from 2965 patients. Radiotherapy and Oncology. 2015;115(3):327-34. doi:https://doi.org/10.1016/j.radonc.2015.05.013. 51. Pappas EP, Alshanqity M, Moutsatsos A, et al. MRI-related geometric distortions in stereotactic radiotherapy treatment planning: evaluation and dosimetric impact. Technol Cancer Res Treat. 2017;16(6):1120-9. doi:10.1177/1533034617735454. 52. Wilson D, Wright, G., Lymer, K., McRobbie, D. Geometric parameters: spatial resolution and distortion. In: McRobbie D, Semple S, editors. IPEM Report 112: Quality control and artefacts in Magnetic Resonance Imaging: Institute of Physics and Engineering in Medicine; 2017. 53. Chen Z, Ma CM, Paskalev K, et al. Investigation of MR image distortion for radiotherapy treatment planning of prostate cancer. Phys Med Biol. 2006;51(6):1393-403. doi:10.1088/0031-9155/51/6/002. 54. Walker A, Liney G, Metcalfe P, Holloway L. MRI distortion: considerations for MRI based radiotherapy treatment planning. Australas Phys Eng Sci Med. 2014;37(1):103-13. doi:10.1007/s13246-014-0252-2. 55. Klein EE, Hanley J, Bayouth J, et al. Task Group 142 report: quality assurance of medical accelerators. Med Phys. 2009;36(9):4197-212. doi:10.1118/1.3190392. 56. Niebuhr NI, Johnen W, Güldaglar T, et al. Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy. Med Phys. 2016;43(2):908-16. doi:10.1118/1.4939874. 57. Menikou G, Dadakova T, Pavlina M, Bock M, Damianou C. MRI compatible head phantom for ultrasound surgery. Ultrasonics. 2015;57:144-52. doi:http://dx.doi.org/10.1016/j.ultras.2014.11.004. 58. Chu KC, Rutt BK. Polyvinyl alcohol cryogel: an ideal phantom material for MR studies of arterial flow and elasticity. Magn Reson Med. 1997;37(2):314-9. 59. Surry KJ, Austin HJ, Fenster A, Peters TM. Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging. Phys Med Biol. 2004;49(24):5529-46. 60. Wardman K, Prestwich RJ, Gooding MJ, Speight RJ. The feasibility of atlas-based automatic segmentation of MRI for H&N radiotherapy planning. J Appl Clin Med Phys. 2016;17(4):146-54. doi:10.1120/jacmp.v17i4.6051. 61. Vinod SK, Jameson MG, Min M, Holloway LC. Uncertainties in volume delineation in radiation oncology: A systematic review and recommendations for future studies. Radiotherapy and Oncology. 2016;121(2):169-79. doi:https://doi.org/10.1016/j.radonc.2016.09.009. 62. Johnstone E, Wyatt JJ, Henry AM, et al. Systematic review of synthetic computed tomography generation methodologies for use in magnetic resonance imaging-only radiation therapy. International Journal of Radiation Oncology • Biology • Physics. 2018;100(1):199-217. doi:10.1016/j.ijrobp.2017.08.043. 63. Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097. doi:10.1371/journal.pmed.1000097. 64. Schad LR, Blüml S, Hawighorst H, Wenz F, Lorenz WJ. Radiosurgical treatment planning of brain metastases based on a fast, three-dimensional MR imaging technique. Magnetic Resonance Imaging. 1994;12(5):811-9. doi:http://dx.doi.org/10.1016/0730-725X(94)92206-3. 65. Ramsey CR, Oliver AL. Magnetic resonance imaging based digitally reconstructed radiographs, virtual simulation, and three-dimensional treatment planning for brain neoplasms. Med Phys. 1998;25(10):1928-34. 66. Prabhakar R, Julka PK, Ganesh T, et al. Feasibility of using MRI alone for 3D radiation treatment planning in brain tumors. Jpn J Clin Oncol. 2007;37. doi:10.1093/jjco/hym050. 67. Wang C, Chao M, Lee L, Xing L. MRI-based treatment planning with electron density information mapped from CT images: a preliminary study. Technol Cancer Res Treat. 2008;7(5):341-8. 68. Weber DC, Wang H, Albrecht S, et al. Open low-field magnetic resonance imaging for target definition, dose calculations and set-up verification during three-dimensional CRT for glioblastoma multiforme. Clinical Oncology (Royal College of Radiologists). 2008;20(2):157-67. 69. Chen L, Price RA, Wang L, et al. MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT. Int J Radiat Oncol Biol Phys. 2004;60. doi:10.1016/j.ijrobp.2004.05.068. 70. Chen L, R. A. Price J, Nguyen TB, et al. Dosimetric evaluation of MRI-based treatment planning for prostate cancer. Phys Med Biol. 2004;49(22):5157. 71. Eilertsen K, Nilsen Tor Arne Vestad L, Geier O, Skretting A. A simulation of MRI based dose calculations on the basis of radiotherapy planning CT images. Acta Oncologica. 2008;47(7):1294-302. doi:10.1080/02841860802256426. 72. Karotki A, Mah K, Meijer G, Meltsner M. Comparison of bulk electron density and voxel-based electron density treatment planning. Journal of Applied Clinical Medical Physics. 2011;12(4):3522. doi:http://dx.doi.org/10.1120/jacmp.v12i4.3522. 73. Korsholm ME, Waring LW, Edmund JM. A criterion for the reliable use of MRI-only radiotherapy. Radiation Oncology. 2014;9:16. doi:http://dx.doi.org/10.1186/1748-717X-9-16. 74. Chin AL, Lin A, Anamalayil S, Teo BK. Feasibility and limitations of bulk density assignment in MRI for head and neck IMRT treatment planning. J Appl Clin Med Phys. 2014;15(5):4851. doi:10.1120/jacmp.v15i5.4851. 75. Doemer A, Chetty IJ, Glide-Hurst C, et al. Evaluating organ delineation, dose calculation and daily localization in an open-MRI simulation workflow for prostate cancer patients. Radiation Oncology. 2015;10(1):1-9. doi:10.1186/s13014-014-0309-0. 76. Jonsson JH, Karlsson MG, Karlsson M, Nyholm T. Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions. Radiation Oncology. 2010;5:62. doi:http://dx.doi.org/10.1186/1748-717X-5-62. 77. Kristensen BH, Laursen FJ, Logager V, Geertsen PF, Krarup-Hansen A. Dosimetric and geometric evaluation of an open low-field magnetic resonance simulator for radiotherapy treatment planning of brain tumours. Radiotherapy & Oncology. 2008;87(1):100-9. doi:http://dx.doi.org/10.1016/j.radonc.2008.01.014. 78. Lambert J, Greer PB, Menk F, et al. MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning. Radiotherapy & Oncology. 2011;98(3):330-4. doi:http://dx.doi.org/10.1016/j.radonc.2011.01.012. 79. Lee YK, Bollet M, Charles-Edwards G, et al. Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone. Radiotherapy & Oncology. 2003;66(2):203-16. 80. Stanescu T, Hans-Sonke J, Pervez N, Stavrev P, Fallone BG. A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions. Phys Med Biol. 2008;53(13):3579-93. doi:10.1088/0031-9155/53/13/013. 81. Stanescu T, Hans-Sonke J, Stavrev P, Fallone G. 3T MR-based treatment planning for radiotherapy of brain lesions. Radiology and Oncology. 2006;40(2):125-32. 82. Ramsey CR, Arwood D, Scaperoth D, Oliver AL. Clinical application of digitally-reconstructed radiographs generated from magnetic resonance imaging for intracranial lesions. International Journal of Radiation Oncology*Biology*Physics. 1999;45(3):797-802. doi:http://dx.doi.org/10.1016/S0360-3016(99)00173-X. 83. Chen L, Nguyen TB, Jones E, et al. Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy: creation of digitally reconstructed radiographs. Int J Radiat Oncol Biol Phys. 2007;68(3):903-11. 84. Hoogcarspel SJ, Van der Velden JM, Lagendijk JJ, van Vulpen M, Raaymakers BW. The feasibility of utilizing pseudo CT-data for online MRI based treatment plan adaptation for a stereotactic radiotherapy treatment of spinal bone metastases. Phys Med Biol. 2014;59(23):7383-91. doi:10.1088/0031-9155/59/23/7383. 85. Dowling JA, Sun J, Pichler P, et al. Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences. Int J Radiat Oncol Biol Phys. 2015;93(5):1144-53. doi:10.1016/j.ijrobp.2015.08.045. 86. Sjolund J, Forsberg D, Andersson M, Knutsson H. Generating patient specific pseudo-CT of the head from MR using atlas-based regression. Phys Med Biol. 2015;60(2):825-39. doi:10.1088/0031-9155/60/2/825. 87. Greer PB, Dowling JA, Lambert JA, et al. A magnetic resonance imaging-based workflow for planning radiation therapy for prostate cancer. Medical Journal of Australia. 2011;194(4):S24-7. 88. Dowling JA, Lambert J, Parker J, et al. An atlas-based electron density mapping method for magnetic resonance imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy. Int J Radiat Oncol Biol Phys. 2012;83(1):e5-11. doi:http://dx.doi.org/10.1016/j.ijrobp.2011.11.056. 89. Uh J, Merchant TE, Li Y, Li X, Hua C. MRI-based treatment planning with pseudo CT generated through atlas registration. Med Phys. 2014;41(5):051711. doi:http://dx.doi.org/10.1118/1.4873315. 90. Siversson C, Nordström F, Nilsson T, et al. Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm. Med Phys. 2015;42(10):6090-7. doi:http://dx.doi.org/10.1118/1.4931417. 91. Andreasen D, Van Leemput K, Edmund JM. A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis. Med Phys. 2016;43(8):4742-52. doi:10.1118/1.4958676. 92. Zhou W, Bovik AC, Sheikh HR, Simoncelli EP. Image quality assessment: from error visibility to structural similarity. IEEE Transactions on Image Processing. 2004;13(4):600-12. doi:10.1109/TIP.2003.819861. 93. Jonsson JH, Johansson A, Soderstrom K, Asklund T, Nyholm T. Treatment planning of intracranial targets on MRI derived substitute CT data. Radiotherapy & Oncology. 2013;108(1):118-22. doi:http://dx.doi.org/10.1016/j.radonc.2013.04.028. 94. Johansson A, Karlsson M, Yu J, Asklund T, Nyholm T. Voxel-wise uncertainty in CT substitute derived from MRI. Med Phys. 2012;39(6):3283-90. doi:http://dx.doi.org/10.1118/1.4711807. 95. Kapanen M, Tenhunen M. T1/T2 -weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning. Acta Oncologica. 2013;52(3):612-8. doi:http://dx.doi.org/10.3109/0284186X.2012.692883. 96. Korhonen J, Kapanen M, Keyrilainen J, Seppala T, Tenhunen M. A dual model HU conversion from MRI intensity values within and outside of bone segment for MRI-based radiotherapy treatment planning of prostate cancer. Med Phys. 2014;41(1):011704. doi:http://dx.doi.org/10.1118/1.4842575. 97. Korhonen J, Kapanen M, Keyrilainen J, et al. Absorbed doses behind bones with MR image-based dose calculations for radiotherapy treatment planning. Med Phys. 2013;40(1):011701. doi:http://dx.doi.org/10.1118/1.4769407. 98. Korhonen J, Kapanen M, Keyrilainen J, et al. Influence of MRI-based bone outline definition errors on external radiotherapy dose calculation accuracy in heterogeneous pseudo-CT images of prostate cancer patients. Acta Oncol. 2014;53(8):1100-6. doi:10.3109/0284186x.2014.929737. 99. Yu H, Caldwell C, Balogh J, Mah K. Toward magnetic resonance-only simulation: segmentation of bone in MR for radiation therapy verification of the head. Int J Radiat Oncol Biol Phys. 2014;89(3):649-57. doi:10.1016/j.ijrobp.2014.03.028. 100. Kim J, Glide-Hurst C, Doemer A, et al. Implementation of a novel algorithm for generating synthetic CT images from magnetic resonance imaging data sets for prostate cancer radiation therapy. Int J Radiat Oncol Biol Phys. 2015;91(1):39-47. doi:http://dx.doi.org/10.1016/j.ijrobp.2014.09.015. 101. Kim J, Garbarino K, Schultz L, et al. Dosimetric evaluation of synthetic CT relative to bulk density assignment-based magnetic resonance-only approaches for prostate radiotherapy. Radiat Oncol. 2015;10:239. doi:10.1186/s13014-015-0549-7. 102. Korhonen J, Kapanen M, Sonke JJ, et al. Feasibility of MRI-based reference images for image-guided radiotherapy of the pelvis with either cone-beam computed tomography or planar localization images. Acta Oncol. 2015;54(6):889-95. doi:10.3109/0284186x.2014.958197. 103. Koivula L, Wee L, Korhonen J. Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images. Med Phys. 2016;43(8):4634. doi:10.1118/1.4958677. 104. Robson MD, Gatehouse PD, Bydder M, Bydder GM. Magnetic resonance: an introduction to ultrashort TE (UTE) imaging. J Comput Assist Tomogr. 2003;27(6):825-46. 105. Larson PEZ, Han M, Krug R, et al. Ultrashort echo time and zero echo time MRI at 7T. Magma (New York, N.Y.). 2016;29(3):359-70. doi:10.1007/s10334-015-0509-0. 106. Lee H, Zhao X, Song HK, et al. Rapid dual-RF, dual-echo, 3D ultrashort echo time craniofacial imaging: A feasibility study. Magn Reson Med. 2019;81(5):3007-16. doi:10.1002/mrm.27625. 107. Rank CM, Hunemohr N, Nagel AM, et al. MRI-based simulation of treatment plans for ion radiotherapy in the brain region. Radiotherapy & Oncology. 2013;109(3):414-8. doi:http://dx.doi.org/10.1016/j.radonc.2013.10.034. 108. Rank CM, Tremmel C, Hunemohr N, et al. MRI-based treatment plan simulation and adaptation for ion radiotherapy using a classification-based approach. Radiation Oncology. 2013;8:51. doi:http://dx.doi.org/10.1186/1748-717X-8-51. 109. Johansson A, Karlsson M, Nyholm T. CT substitute derived from MRI sequences with ultrashort echo time. Med Phys. 2011;38(5):2708-14. doi:http://dx.doi.org/10.1118/1.3578928. 110. Johansson A, Garpebring A, Karlsson M, Asklund T, Nyholm T. Improved quality of computed tomography substitute derived from magnetic resonance (MR) data by incorporation of spatial information--potential application for MR-only radiotherapy and attenuation correction in positron emission tomography. Acta Oncologica. 2013;52(7):1369-73. doi:http://dx.doi.org/10.3109/0284186X.2013.819119. 111. Johansson A, Garpebring A, Asklund T, Nyholm T. CT substitutes derived from MR images reconstructed with parallel imaging. Med Phys. 2014;41(8):082302. doi:http://dx.doi.org/10.1118/1.4886766. 112. Hsu SH, Cao Y, Huang K, Feng M, Balter JM. Investigation of a method for generating synthetic CT models from MRI scans of the head and neck for radiotherapy. Phys Med Biol. 2013;58. doi:10.1088/0031-9155/58/23/8419. 113. Edmund JM, Kjer HM, Van Leemput K, et al. A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times. Phys Med Biol. 2014;59(23):7501-19. doi:10.1088/0031-9155/59/23/7501. 114. Jonsson JH, Akhtari MM, Karlsson MG, et al. Accuracy of inverse treatment planning on substitute CT images derived from MR data for brain lesions. Radiation Oncology. 2015;10(1):1-7. doi:10.1186/s13014-014-0308-1. 115. Hsu SH, Cao Y, Lawrence TS, et al. Quantitative characterizations of ultrashort echo (UTE) images for supporting air-bone separation in the head. Phys Med Biol. 2015;60(7):2869-80. doi:10.1088/0031-9155/60/7/2869. 116. Paradis E, Cao Y, Lawrence TS, et al. Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy. Int J Radiat Oncol Biol Phys. 2015;93(5):1154-61. doi:10.1016/j.ijrobp.2015.08.049. 117. Zheng W, Kim JP, Kadbi M, et al. Magnetic Resonance-Based Automatic Air Segmentation for Generation of Synthetic Computed Tomography Scans in the Head Region. Int J Radiat Oncol Biol Phys. 2015;93(3):497-506. doi:10.1016/j.ijrobp.2015.07.001. 118. Gutierrez S, Descamps B, Vanhove C. MRI-Only Based Radiotherapy Treatment Planning for the Rat Brain on a Small Animal Radiation Research Platform (SARRP). PLoS One. 2015;10(12):e0143821. doi:10.1371/journal.pone.0143821. 119. Price RG, Kim JP, Zheng W, Chetty IJ, Glide-Hurst C. Image Guided Radiation Therapy Using Synthetic Computed Tomography Images in Brain Cancer. Int J Radiat Oncol Biol Phys. 2016;95(4):1281-9. doi:10.1016/j.ijrobp.2016.03.002. 120. Yang Y, Cao M, Kaprealian T, et al. Accuracy of UTE-MRI-based patient setup for brain cancer radiation therapy. Med Phys. 2016;43(1):262-7. doi:10.1118/1.4938266. 121. Grodzki DM, Jakob PM, Heismann B. Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA). Magn Reson Med. 2012;67(2):510-8. doi:10.1002/mrm.23017. 122. Gudur MS, Hara W, Le QT, et al. A unifying probabilistic Bayesian approach to derive electron density from MRI for radiation therapy treatment planning. Phys Med Biol. 2014;59(21):6595-606. doi:10.1088/0031-9155/59/21/6595. 123. Keereman V, Fierens Y, Broux T, et al. MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences. J Nucl Med. 2010;51(5):812-8. doi:10.2967/jnumed.109.065425. 124. Perkins G. (Personal correspondance). Philips Electronics UK Ltd; 2017. 125. Greer PB. (Personal correspondance). Calvary Mater Newcastle, Newcastle, Australia;2017. 126. Han X. MR-based synthetic CT generation using a deep convolutional neural network method. Med Phys. 2017;44(4):1408-19. doi:10.1002/mp.12155. 127. Largent A, Barateau A, Nunes JC, et al. Pseudo-CT Generation for MRI-Only Radiation Therapy Treatment Planning: Comparison Among Patch-Based, Atlas-Based, and Bulk Density Methods. Int J Radiat Oncol Biol Phys. 2019;103(2):479-90. doi:10.1016/j.ijrobp.2018.10.002. 128. Emami H, Dong M, Nejad-Davarani SP, Glide-Hurst CK. Generating synthetic CTs from magnetic resonance images using generative adversarial networks. Med Phys. 2018. doi:10.1002/mp.13047. 129. Dinkla AM, Wolterink JM, Maspero M, et al. MR-Only Brain Radiation Therapy: Dosimetric Evaluation of Synthetic CTs Generated by a Dilated Convolutional Neural Network. Int J Radiat Oncol Biol Phys. 2018;102(4):801-12. doi:10.1016/j.ijrobp.2018.05.058. 130. Maspero M, Savenije MHF, Dinkla AM, et al. Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy. Phys Med Biol. 2018;63(18):185001. doi:10.1088/1361-6560/aada6d. 131. Fedorov A, Beichel R, Kalpathy-Cramer J, et al. 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging. 2012;30(9):1323-41. doi:10.1016/j.mri.2012.05.001. 132. Eaton J, Bateman D, Hauberg S, Wehbring R. GNU Octave version 4.0.0 manual: a high-level interactive language for numerical computations 2015. Available from: http://www.gnu.org/software/octave/doc/interpreter. 133. Pinter C, Lasso A, Wang A, Jaffray D, Fichtinger G. SlicerRT: radiation therapy research toolkit for 3D Slicer. Med Phys. 2012;39(10):6332-8. doi:10.1118/1.4754659. 134. Aljabar P, Heckemann RA, Hammers A, Hajnal JV, Rueckert D. Multi-atlas based segmentation of brain images: Atlas selection and its effect on accuracy. Neuroimage. 2009;46(3):726-38. doi:https://doi.org/10.1016/j.neuroimage.2009.02.018. 135. Siversson C, Akhondi-Asl A, Bixby S, Kim YJ, Warfield SK. Three-dimensional hip cartilage quality assessment of morphology and dGEMRIC by planar maps and automated segmentation. Osteoarthritis Cartilage. 2014;22(10):1511-5. doi:10.1016/j.joca.2014.08.012. 136. Report 83. Journal of the International Commission on Radiation Units and Measurements. 2010;10(1). doi:10.1093/jicru/10.1.Report83. 137. Kamalian S, Lev MH, Gupta R. Chapter 1 - Computed tomography imaging and angiography – principles. In: Masdeu JC, González RG, editors. Handbook of Clinical Neurology. 135: Elsevier; 2016. p. 3-20. 138. Lustberg T, van Soest J, Gooding M, et al. Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer. Radiother Oncol. 2018;126(2):312-7. doi:10.1016/j.radonc.2017.11.012. 139. Sharp G, Fritscher KD, Pekar V, et al. Vision 20/20: Perspectives on automated image segmentation for radiotherapy. Med Phys. 2016;41(5):050902. doi:10.1118/1.4871620. 140. Bauer S, Wiest R, Nolte LP, Reyes M. A survey of MRI-based medical image analysis for brain tumor studies. Phys Med Biol. 2013;58(13):R97-129. doi:10.1088/0031-9155/58/13/r97. 141. Eekers DBP, in 't Ven L, Roelofs E, et al. The EPTN consensus-based atlas for CT- and MR-based contouring in neuro-oncology. Radiotherapy and Oncology. 2018;128(1):37-43. doi:https://doi.org/10.1016/j.radonc.2017.12.013. 142. Scoccianti S, Detti B, Gadda D, et al. Organs at risk in the brain and their dose-constraints in adults and in children: a radiation oncologist's guide for delineation in everyday practice. Radiother Oncol. 2015;114(2):230-8. doi:10.1016/j.radonc.2015.01.016. 143. Dice LR. Measures of the Amount of Ecologic Association Between Species. Ecology. 1945;26(3):297-302. doi:10.2307/1932409. 144. Chuter R, Prestwich R, Bird D, et al. The use of deformable image registration to integrate diagnostic MRI into the radiotherapy planning pathway for head and neck cancer. Radiotherapy and Oncology. 2017;122(2):229-35. doi:10.1016/j.radonc.2016.07.016. 145. Jena R, Kirkby NF, Burton KE, et al. A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes. Br J Radiol. 2010;83(985):44-51. doi:10.1259/bjr/27674581. 146. Hughes GK, Miszkiel KA. Imaging of the Lacrimal Gland. Seminars in Ultrasound, CT and MRI. 2006;27(6):476-91. doi:https://doi.org/10.1053/j.sult.2006.09.002. 147. Evanson J. Radiology of the Pituitary. South Dartmouth (MA)2016. Available from: https://www.ncbi.nlm.nih.gov/books/NBK279161/. 148. Isambert A, Dhermain F, Bidault F, et al. Evaluation of an atlas-based automatic segmentation software for the delineation of brain organs at risk in a radiation therapy clinical context. Radiotherapy and Oncology. 2008;87(1):93. doi:https://doi.org/10.1016/j.radonc.2007.11.030. 149. Brouwer CL, Steenbakkers RJHM, Bourhis J, et al. CT-based delineation of organs at risk in the head and neck region: DAHANCA, EORTC, GORTEC, HKNPCSG, NCIC CTG, NCRI, NRG Oncology and TROG consensus guidelines. Radiotherapy and Oncology. 2015;117(1):83-90. doi:10.1016/j.radonc.2015.07.041. 150. Price RG, Knight RA, Hwang K-P, et al. Optimization of a novel large field of view distortion phantom for MR-only treatment planning. Journal of Applied Clinical Medical Physics. 2017;18(4):51-61. doi:10.1002/acm2.12090. 151. Walker A, Liney G, Holloway L, et al. Continuous table acquisition MRI for radiotherapy treatment planning: distortion assessment with a new extended 3D volumetric phantom. Med Phys. 2015;42(4):1982-91. doi:10.1118/1.4915920. 152. Torfeh T, Hammoud R, Perkins G, et al. Characterization of 3D geometric distortion of magnetic resonance imaging scanners commissioned for radiation therapy planning. Magnetic Resonance Imaging. 2016;34(5):645-53. doi:https://doi.org/10.1016/j.mri.2016.01.001. 153. Moerland MA. Magnetic resonance imaging in radiotherapy treatment planning: University of Utrecht; 1996. 154. Ahmed M, Schmidt M, Sohaib A, et al. The value of magnetic resonance imaging in target volume delineation of base of tongue tumours – A study using flexible surface coils. Radiotherapy and Oncology. 2010;94(2):161-7. doi:https://doi.org/10.1016/j.radonc.2009.12.021. 155. Mizowaki T, Nagata Y, Okajima K, et al. Reproducibility of geometric distortion in magnetic resonance imaging based on phantom studies. Radiother Oncol. 2000;57(2):237-42. 156. Boas M. Binomial distribution. Mathematical Methods in the Physical Sciences. 2nd ed: John Wiley and sons; 1983. 157. NIST/SEMATECH. Measures of skewness and kurtosis. In: NIST/ SEMATECH e-Handbook of statistical methods. National Institute of Standards and Technology, United States Department of Commerce; 2013. http://www.itl.nist.gov/div898/handbook/eda/section3/eda35b.htm. Accessed 09/03/2018. 158. Paulson ES, Erickson B, Schultz C, Li XA. Comprehensive MRI simulation methodology using a dedicated MRI scanner in radiation oncology for external beam radiation treatment planning. Med Phys. 2015;42(1):28-39. doi:10.1118/1.4896096. 159. Mah D, Steckner M, Palacio E, et al. Characteristics and quality assurance of a dedicated open 0.23 T MRI for radiation therapy simulation. Med Phys. 2002;29(11):2541-7. doi:10.1118/1.1513991. 160. Price RG, Kadbi M, Kim J, et al. Technical note: characterization and correction of gradient nonlinearity induced distortion on a 1.0 T open bore MR-SIM. Med Phys. 2015;42(10):5955-60. doi:10.1118/1.4930245. 161. Baldwin LN, Wachowicz K, Thomas SD, Rivest R, Fallone BG. Characterization, prediction, and correction of geometric distortion in 3 T MR images. Med Phys. 2007;34(2):388-99. doi:10.1118/1.2402331. 162. Kapanen M, Collan J, Beule A, et al. Commissioning of MRI-only based treatment planning procedure for external beam radiotherapy of prostate. Magn Reson Med. 2013;70(1):127-35. doi:10.1002/mrm.24459. 163. Damyanovich AZ, Rieker M, Zhang B, Bissonnette JP, Jaffray DA. Design and implementation of a 3D-MR/CT geometric image distortion phantom/analysis system for stereotactic radiosurgery. Phys Med Biol. 2018;63(7):075010. doi:10.1088/1361-6560/aab33e. 164. Chen HH, Boykin RD, Clarke GD, Gao JH, Roby JW, 3rd. Routine testing of magnetic field homogeneity on clinical MRI systems. Med Phys. 2006;33(11):4299-306. doi:10.1118/1.2359229. 165. Schenck JF. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys. 1996;23(6):815-50. doi:10.1118/1.597854. 166. Haidekker MA. Magnetic Resonance Imaging. Medical Imaging Technology. New York: Springer Science & Business Media; 2013. 167. Rasband WS. ImageJ. U. S. National Institutes of Health, Bethesda, Maryland, USA1997-2018. 168. Schneider CA, Rasband WS, Eliceiri KW. NIH Image to ImageJ: 25 years of image analysis. Nature Methods. 2012;9:671. doi:10.1038/nmeth.2089. 169. Leymarie F, Levine MD. Fast raster scan distance propagation on the discrete rectangular lattice. CVGIP: Image Understanding. 1992;55(1):84-94. doi:https://doi.org/10.1016/1049-9660(92)90008-Q. 170. Cancer Research UK. Brain, other CNS and intracranial tumours incidence statistics 2019. Available from: https://www.cancerresearchuk.org/health-professional/cancer-statistics/statistics-by-cancer-type/brain-other-cns-and-intracranial-tumours/incidence#heading-One. Date accessed: 09/02/2019. 171. Gallas RR, Hunemohr N, Runz A, et al. An anthropomorphic multimodality (CT/MRI) head phantom prototype for end-to-end tests in ion radiotherapy. Z Med Phys. 2015;25(4):391-9. doi:10.1016/j.zemedi.2015.05.003. 172. Fortune S, Jansen MA, Anderson T, et al. Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging. Magnetic Resonance Imaging. 2012;30(8):1186-91. doi:https://doi.org/10.1016/j.mri.2012.04.008. 173. Dental treatments: NHS Choices; updated 25/11/2015. Available from: http://www.nhs.uk/Livewell/dentalhealth/Pages/Dentaltreatments.aspx. Date accessed: 14/08/2017. 174. Mail N, Albarakati Y, Ahmad Khan M, et al. The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution. Med Phys. 2013;40(8):081714. doi:10.1118/1.4816307. 175. Allahverdi M, Nisbet A, Thwaites DI. An evaluation of epoxy resin phantom materials for megavoltage photon dosimetry. Physics in Medicine & Biology. 1999;44(5):1125. 176. Messroghli DR, Radjenovic A, Kozerke S, et al. Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magnetic Resonance in Medicine. 2004;52(1):141-6. doi:10.1002/mrm.20110. 177. Formula Saint-Gobain. Crystacal R 2019. Available from: https://www.saintgobainformula.com/product/crystacal-r. Date accessed: 09/02/2019. 178. Formula Saint-Gobain. Dental Plaster 2019. Available from: https://www.saintgobainformula.com/product/dental-plaster. Date accessed: 09/02/2019. 179. Bojorquez JZ, Bricq S, Acquitter C, et al. What are normal relaxation times of tissues at 3 T? Magnetic Resonance Imaging. 2017;35:69-80. doi:https://doi.org/10.1016/j.mri.2016.08.021. 180. Kim S, Lee GH, Lee S, et al. Body fat measurement in computed tomography image. Biomed Sci Instrum. 1999;35:303-8. 181. Yushkevich PA, Piven J, Hazlett HC, et al. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage. 2006;31(3):1116-28. doi:10.1016/j.neuroimage.2006.01.015. 182. Persson E, Gustafsson C, Nordstrom F, et al. MR-OPERA: A Multicenter/Multivendor Validation of Magnetic Resonance Imaging-Only Prostate Treatment Planning Using Synthetic Computed Tomography Images. Int J Radiat Oncol Biol Phys. 2017;99(3):692-700. doi:10.1016/j.ijrobp.2017.06.006. 183. Bridge P, Fielding A, Rowntree P, Pullar A. Intraobserver Variability: Should We Worry? Journal of Medical Imaging and Radiation Sciences. 2016;47(3):217-20. doi:10.1016/j.jmir.2016.06.004."],"dcterms:accessrights":["public"],"dc:title":["Automated MRI-based radiotherapy planning for brain tumours"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:35:36Z"}