{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:26885"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:26885","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Understanding Movement and its Influence on Tribology of the Human Hip","abstract":"Total hip arthroplasty is one of the most successful and innovative medical procedures developed during the 20th century. Success post-op has been shown to decrease for younger, more active patients when compared to those who are older and less active, raising concerns surrounding the reasons behind the increased risk of prosthesis failure for some individuals. Sliding distance, cross-shear, load and edge loading are important factors when determining potential wear rates at the hip. Global and local hip biomechanics were calculated for eighteen healthy subjects, completing thirteen common daily activities. Results showed variation in cross-shear motion and hip reaction forces between individuals and across activities. Variation in motion paths and loading, between and within activities, suggested variation in the fluid film thickness and corresponding lubrication regimes at the joint. Walking tasks showed high levels of cross-shear and the potential for excessive wear both at initial contact and heel-off. More linear activities, such as sitting and standing, showed low cross-shear alongside a potential risk of posterior edge loading. Tribological discrepancies were shown between hip simulator input data (ISO) and measured walking data, with the ISO cycle potentially underestimating cross-shear wear at initial contact, during walking. Results provide detailed data that may facilitate improvements in the reliability of pre-clinical testing for hip prostheses and tissue engineered cartilage substitution. The data indicates that durability testing standards should consider incorporating a range of activities, rather than just walking, and aim to represent the variability shown between individuals. Results also provide evidence for determining the appropriateness of specific activities/ rehabilitation for post-operative total hip replacement patients.","abstract_html":"Total hip arthroplasty is one of the most successful and innovative medical procedures developed during the 20th century. Success post-op has been shown to decrease for younger, more active patients when compared to those who are older and less active, raising concerns surrounding the reasons behind the increased risk of prosthesis failure for some individuals. Sliding distance, cross-shear, load and edge loading are important factors when determining potential wear rates at the hip. Global and local hip biomechanics were calculated for eighteen healthy subjects, completing thirteen common daily activities. Results showed variation in cross-shear motion and hip reaction forces between individuals and across activities. Variation in motion paths and loading, between and within activities, suggested variation in the fluid film thickness and corresponding lubrication regimes at the joint. Walking tasks showed high levels of cross-shear and the potential for excessive wear both at initial contact and heel-off. More linear activities, such as sitting and standing, showed low cross-shear alongside a potential risk of posterior edge loading. Tribological discrepancies were shown between hip simulator input data (ISO) and measured walking data, with the ISO cycle potentially underestimating cross-shear wear at initial contact, during walking. Results provide detailed data that may facilitate improvements in the reliability of pre-clinical testing for hip prostheses and tissue engineered cartilage substitution. The data indicates that durability testing standards should consider incorporating a range of activities, rather than just walking, and aim to represent the variability shown between individuals. Results also provide evidence for determining the appropriateness of specific activities/ rehabilitation for post-operative total hip replacement patients.","abstract_has_math":false,"creators":["Layton, Robin B."],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Stewart, Todd","Messenger, Neil"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-04","date_published":"2020-04","updated_at":"2026-11-18T22:38:08Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.805369"],"render_values":[{"text":"uk.bl.ethos.805369","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["484643"],"render_values":[{"text":"484643","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/26885/1/Layton_Thesis_2020.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A26885","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Stewart, Todd","Messenger, Neil"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["UK Engineering and Physical Sciences Research Council (EPSRC)"]},{"key":"dc:creator","label":"Author","values":["Layton, Robin B."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-04"]},{"key":"dc:date.issued","label":"Date","values":["2020-04"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/26885/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Abdel, M. et al. 2016a. What is the lifetime risk of revision for patients undergoing total hip arthroplasty? a 40-year observational study of patients treated with the Charnley cemented total hip arthroplasty. The bone & joint journal. 98(11), pp.1436-1440. Abdel, M.P. et al. 2016b. What safe zone? The vast majority of dislocated THAs are within the Lewinnek safe zone for acetabular component position. Clinical Orthopaedics and Related Research®. 474(2), pp.386-391. Adams, J. and Hamblen, D. 2001. Outline of Orthopaedics. Thirteenth ed. London: Churchill Livingstone. Al-Hajjar, M. et al. 2013. Wear of 36-mm BIOLOX® delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 227(5), pp.535-542. Al‐Hajjar, M. et al. 2017. Wear of composite ceramics in mixed‐material combinations in total hip replacement under adverse edge loading conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 105(6), pp.1361-1368. Al‐Hajjar, M. et al. 2013. Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge‐loading conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 101(2), pp.213-222. Al‐Hajjar, M. et al. 2010. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic‐on‐ceramic total hip replacement. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 95(2), pp.263-268. AnyBody. 2019. Any Tutorials. [Online]. Available from: https://anyscript.org/tutorials/index.html. Archard, J. 1953. Contact and rubbing of flat surfaces. Journal of applied physics. 24(8), pp.981-988. Banaszkiewicz, P.A. 2014. Dislocations after total hip-replacement arthroplasties. In Classic Papers in Orthopaedics. London: Springer. Barbour, P. et al. 1997. The influence of stress conditions on the wear of UHMWPE for total joint replacements. Journal of materials science: Materials in medicine. 8(10), pp.603-611. Barbour, P. et al. 1999. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 213(6), pp.455-467. Barbour, P. et al. 2000. A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 214(6), pp.569-576. Barnett, J. 2009. Motions in Space: The Motions of Femoral Heads over Acetabular Cups. MSc thesis, University of Leeds. 329 | P a g e Barré, A. et al. 2015. Soft tissue artifact distribution on lower limbs during treadmill gait: influence of skin markers' location on cluster design. Journal of biomechanics. 48(10), pp.1965-1971. Barry, J.J. et al. 2018. Recovery and outcomes of direct anterior approach total hip arthroplasty. Annals of Joint. 3(6). Bartel, D. et al. 1985. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. Journal of Biomechanical Engineering. 107(3), pp.193-199. Beaupre, L.A. et al. 2013. A randomized trial of ceramic-on-ceramic bearing versus ceramic-on-crossfire-polyethylene bearing in total hip arthroplasty: five-year outcomes. The Journal of arthroplasty. 28(3), pp.485-489. Bell, A.L. et al. 1989. Prediction of hip joint centre location from external landmarks. Human Movement Science. 8(1), pp.3-16. Bell, A.L. et al. 1990. A comparison of the accuracy of several hip center location prediction methods. Journal of biomechanics. 23(6), pp.617-621. Bennett, D. et al. 2008. The influence of wear paths produced by hip replacement patients during normal walking on wear rates. Journal of Orthopaedic Research. 26(9), pp.1210-1217. Bennett, D. et al. 2002. The influence of shape and sliding distance of femoral head movement loci on the wear of acetabular cups in total hip arthroplasty. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 216(6), pp.393-402. Bennett, D.B. et al. 2000. Movement loci of selected points on the femoral head for individual total hip arthroplasty patients using three-dimensional computer simulation. The Journal of arthroplasty. 15(7), pp.909-915. Bergmann, G. et al. 2001. Hip contact forces and gait patterns from routine activities. Journal of biomechanics. 34(7), pp.859-871. Bergmann, G. et al. 1993. Hip joint loading during walking and running, measured in two patients. Journal of biomechanics. 26(8), pp.969-990. Bergmann, G. et al. 1995. Is staircase walking a risk for the fixation of hip implants? Journal of biomechanics. 28(5), pp.535-553. Bini, R. et al. 2019. Biomechanical and physiological responses to electrically assisted cycling during simulated mail delivery. Applied Ergonomics. 75, pp.243-249. Bosker, B. et al. 2007. Poor accuracy of freehand cup positioning during total hip arthroplasty. Archives of orthopaedic and trauma surgery. 127(5), pp.375-379. Bowsher, J. and Shelton, J. 2001. A hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions. Wear. 250(1-12), pp.167-179. Bozic, K.J. et al. 2010. Risk of complication and revision total hip arthroplasty among Medicare patients with different bearing surfaces. Clinical Orthopaedics and Related Research®. 468(9), pp.2357-2362. Bragdon, C. et al. 1996. The importance of multidirectional motion on the wear of polyethylene. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 210(3), pp.157-165. 330 | P a g e Brand, R.A. et al. 1994. Comparison of hip force calculations and measurements in the same patient. The Journal of arthroplasty. 9(1), pp.45-51. Bremer, A. et al. 2011. Soft-tissue changes in hip abductor muscles and tendons after total hip replacement: comparison between the direct anterior and the transgluteal approaches. The Journal of bone and joint surgery. British volume. 93(7), pp.886-889. Brown, M. et al. 1980. Walking efficiency before and after total hip replacement. Physical therapy. 60(10), pp.1259-1263. Buckwalter, J.A. et al. 2000. Orthopaedic basic science : biology and biomechanics of the musculoskeletal system. Rosemont, IL: American Academy of Orthopaedic Surgeons. Budenberg, S. et al. 2012. Contact surface motion paths associated with leg length inequality following unilateral total hip replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 226(12), pp.968-974. C-Motion. 2018. Visual3D Tutorials. [Online]. [Accessed 13 September]. Available from: www.c-motion.com. Calonius, O. and Saikko, V. 2002. Slide track analysis of eight contemporary hip simulator designs. Journal of Biomechanics. 35(11), pp.1439-1450. Calonius, O. and Saikko, V. 2003. Force track analysis of contemporary hip simulators. Journal of biomechanics. 36(11), pp.1719-1726. Cappozzo, A. et al. 1995. Position and orientation in space of bones during movement: anatomical frame definition and determination. Clinical biomechanics. 10(4), pp.171-178. Carbone, V. et al. 2015. TLEM 2.0–A comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity. Journal of biomechanics. 48(5), pp.734-741. Chahal, J. et al. 2013. Managing the patient with failed cartilage restoration. Sports medicine and arthroscopy review. 21(2), pp.62-68. Chao, E. et al. 1983. Normative data of knee joint motion and ground reaction forces in adult level walking. Journal of biomechanics. 16(3), pp.219-233. Charnley, J. 1970. 2 Total Hip Replacement by Low-Friction Arthroplasty. Clinical Orthopaedics and Related Research®. 72, pp.7-21. Charnley, J. et al. 1969. The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Medical and biological engineering. 7(1), pp.31-39. Chatterji, U. et al. 2004. Effect of total hip arthroplasty on recreational and sporting activity. ANZ journal of surgery. 74(6), pp.446-449. Choi, B.C. et al. 2007. Daily step goal of 10,000 steps: a literature review. Clinical & Investigative Medicine. 30(3), pp.146-151. Clifford, P.E. and Mallon, W.J. 2005. Sports after total joint replacement. Clinics in sports medicine. 24(1), pp.175-186. Cooper, J. et al. 1993. Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene. Wear. 162, pp.378-384. 331 | P a g e Crombie, I.K. et al. 2004. Why older people do not participate in leisure time physical activity: a survey of activity levels, beliefs and deterrents. Age and ageing. 33(3), pp.287-292. Crowninshield, R. et al. 1978. A biomechanical investigation of the human hip. Journal of biomechanics. 11(1), pp.79-85. D’antonio, J.A. et al. 2012. Ceramic bearings for total hip arthroplasty have high survivorship at 10 years. Clinical Orthopaedics and Related Research®. 470(2), pp.373-381. Damm, P. et al. 2013a. Friction in total hip joint prosthesis measured in vivo during walking. PLoS One. 8(11), pe78373. Damm, P. et al. 2013b. In vivo hip joint loads during three methods of walking with forearm crutches. Clinical Biomechanics. 28(5), pp.530-535. Davy, D. et al. 1988. Telemetric force measurements across the hip after total arthroplasty. The Journal of bone and joint surgery. American volume. 70(1), pp.45-50. De Pieri, E. et al. 2019. Patient Characteristics Affect Hip Contact Forces during Gait. Osteoarthritis and Cartilage. Delasotta, L.A. et al. 2012. What are young patients doing after hip reconstruction? The Journal of arthroplasty. 27(8), pp.1518-1525. e2. Dewolf, A.H. et al. 2018. Kinematic patterns while walking on a slope at different speeds. Journal of Applied Physiology. Donahue, G.S. et al. 2016. Are females at greater risk for revision surgery after hip resurfacing arthroplasty with the articular surface replacement prosthesis? Clinical Orthopaedics and Related Research®. 474(10), pp.2257-2265. Dorlot, J.-M. 1992. Long-term effects of alumina components in total hip prostheses. Clinical orthopaedics and related research. (282), pp.47-52. Dowson, D. and Jobbins, B. 1988. Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints. Engineering in medicine. 17(3), pp.111-117. Dressler, M.R. et al. 2011. Predicting wear of UHMWPE: Decreasing wear rate following a change in direction. Wear. 271(11-12), pp.2879-2883. Dubs, L. et al. 1983. Sport after total hip arthroplasty. Archives of orthopädic and traumatic Surgery. 101(3), pp.161-169. Dumbleton, J.H. et al. 2006. The basis for a second-generation highly cross-linked UHMWPE. Clinical orthopaedics and related research. 453, pp.265-271. Esposito, C. et al. 2012. Wear in alumina-on-alumina ceramic total hip replacements: a retrieval analysis of edge loading. The Journal of bone and joint surgery. British volume. 94(7), pp.901-907. Evans, J.T. et al. 2019. How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up. The Lancet. 393(10172), pp.647-654. Ewen, A.M. et al. 2012. Post-operative gait analysis in total hip replacement patients—a review of current literature and meta-analysis. Gait & posture. 36(1), pp.1-6. 332 | P a g e Farrokhi, S. et al. 2008. Trunk position influences the kinematics, kinetics, and muscle activity of the lead lower extremity during the forward lunge exercise. journal of orthopaedic & sports physical therapy. 38(7), pp.403-409. Field, A. 2013. Discovering statistics using IBM SPSS statistics. sage. Firkins, P. et al. 2001. Quantitative analysis of wear and wear debris from metal‐on‐metal hip prostheses tested in a physiological hip joint simulator. Bio-Medical Materials and Engineering. 11(2), pp.143-157. Flanagan, S. et al. 2003. Squatting exercises in older adults: kinematic and kinetic comparisons. Medicine and science in sports and exercise. 35(4), p635. Flanagan, S.P. et al. 2004. Biomechanical attributes of lunging activities for older adults. Journal of strength and conditioning research/National Strength & Conditioning Association. 18(3), p599. Forster, E. 2004. Predicting muscle forces in the human lower limb during locomotion. thesis, Universität Ulm. Foucher, K. et al. 1999. Gait adaptations in postoperative total hip replacement patients are associated with reduced hip contact forces. In: 23rd Annual Meeting of American Society of Biomechanics, Pittsburgh, Pennsylvania, pp.134-135. Foucher, K.C. 2016. Identifying clinically meaningful benchmarks for gait improvement after total hip arthroplasty. Journal of Orthopaedic Research. 34(1), pp.88-96. Foucher, K.C. et al. 2007. Preoperative gait adaptations persist one year after surgery in clinically well-functioning total hip replacement patients. Journal of biomechanics. 40(15), pp.3432-3437. Foucher, K.C. et al. 2008. Do gait adaptations during stair climbing result in changes in implant forces in subjects with total hip replacements compared to normal subjects? Clinical Biomechanics. 23(6), pp.754-761. Fox, A.S. 2018. Change-of-Direction Biomechanics: Is What’s Best for Anterior Cruciate Ligament Injury Prevention Also Best for Performance? Sports Medicine. pp.1-9. Franjcic, Z. and Wozniak, P.W. 2014. QualiWand: Towards Optimising Feedback for Motion Capture System Calibration. In: Graphics Interface 2014 Poster Session Proceedings, pp.5-6. Fumes, O. et al. 2001. Hip disease and the prognosis of total hip replacements: A review of 53 698 primary total hip replacements reported to the Norwegian arthroplasty register 1987-99. Journal of bone and joint surgery. British volume. 83(4), pp.579-586. Galante, J.O. and Rostoker, W. 1972. Wear in total hip prostheses: an experimental evaluation of candidate materials. Acta Orthopaedica Scandinavica. 43(sup145), pp.1-46. Galvin, A. et al. 2006. Wear of crosslinked polyethylene under different tribological conditions. Journal of Materials Science: Materials in Medicine. 17(3), pp.235-243. Geduldig, D. et al. 1976. Experimental investigations of dense alumina ceramic for hip and knee joint replacements. Engineering in Medicine. Springer, pp.434-445. Gholizadeh, H. et al. 2018. Transtibial amputee gait during slope walking with the unity suspension system. Gait & posture. 65, pp.205-212. 333 | P a g e Goldsmith, A. et al. 2000. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 214(1), pp.39-47. Goldsmith, A. et al. 2001. The effect of activity levels of total hip arthroplasty patients on socket penetration. The Journal of arthroplasty. 16(5), pp.620-627. Gomez, P.F. and Morcuende, J.A. 2005. Early attempts at hip arthroplasty: 1700s to 1950s. The Iowa orthopaedic journal. 25, p25. Granata, K.P. et al. 2000. Joint angular velocity in spastic gait and the influence of muscle-tendon lengthening. The Journal of bone and joint surgery. American volume. 82(2), p174. Griffith, M. et al. 1978. Socket wear in Charnley low friction arthroplasty of the hip. Clinical orthopaedics and related research. (137), pp.37-47. Gschwend, N. et al. 2000. Alpine and cross-country skiing after total hip replacement: 2 cohorts of 50 patients each, one active, the other inactive in skiing, followed for 5-10 years. Acta Orthopaedica Scandinavica. 71(3), pp.243-249. Gulgin, H. et al. 2009. Hip rotational velocities during the full golf swing. Journal of Sports Science and Medicine. 8(2), pp.296-9. Haberly, G. and Pavol, M. 2013. Hip loading during the squat exercise. Masters of science thesis, George Fox University. Hall, R. et al. 1996. Wear in retrieved Charnley acetabular sockets. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 210(3), pp.197-207. Hamill, J. et al. 1984. Ground reaction force symmetry during walking and running. Research Quarterly for Exercise and Sport. 55(3), pp.289-293. Hamill, J. and Knutzen, K.M. 2006. Biomechanical basis of human movement. Lippincott Williams & Wilkins. Hamrock, B.J. and Dowson, D. 1978. Elastohydrodynamic lubrication of elliptical contacts for materials of low elastic modulus I—fully flooded conjunction. Journal of Lubrication Technology. 100(2), pp.236-245. Hannouche, D. et al. 2016. Ceramic-on-ceramic THA implants in patients younger than 20 years. Clinical Orthopaedics and Related Research®. 474(2), pp.520-527. Harris, W.H. 1995. The problem is osteolysis. Clinical orthopaedics and related research. (311), pp.46-53. Hart, A. et al. 2013. Which factors determine the wear rate of large-diameter metal-on-metal hip replacements?: Multivariate analysis of two hundred and seventy-six components. JBJS. 95(8), pp.678-685. Healy, W.L. et al. 2008. Athletic activity after total joint arthroplasty. JBJS. 90(10), pp.2245-2252. Heller, M. et al. 2001. Musculo-skeletal loading conditions at the hip during walking and stair climbing. Journal of biomechanics. 34(7), pp.883-893. Hemmerich, A. et al. 2006. Hip, knee, and ankle kinematics of high range of motion activities of daily living. Journal of orthopaedic research. 24(4), pp.770-781. 334 | P a g e Herzog, W. et al. 1989. Asymmetries in ground reaction force patterns in normal human gait. Med Sci Sports Exerc. 21(1), pp.110-114. Higginson, G. 1978. Squeeze films between compliant solids. Wear. 46(2), pp.387-395. Horsman, M.K. 2007. The Twente lower extremity model. Consistent dynamic simulation of the human locomotor apparatus. Hua, X. et al. 2016. The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities. Medical engineering & physics. 38(6), pp.518-525. Huch, K. et al. 2005. Sports activities 5 years after total knee or hip arthroplasty: the Ulm Osteoarthritis Study. Annals of the rheumatic diseases. 64(12), pp.1715-1720. Hume, P.A. et al. 2005. The role of biomechanics in maximising distance and accuracy of golf shots. Sports medicine. 35(5), pp.429-449. Ingham, E. and Fisher, J. 2005. The role of macrophages in osteolysis of total joint replacement. Biomaterials. 26(11), pp.1271-1286. ISO. 2014. ISO 14242-1. Implants for surgery — Wear of total hip-joint prostheses — Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test. [Online]. [Accessed 10-06-2019]. Available from: https://www.iso.org/obp/ui/#iso:std:iso:14242:-1:ed-3:v1:en:fig:1. Jacobs, N. et al. 1972. Analysis of the vertical component of force in normal and pathological gait. Journal of Biomechanics. 5(1), pp.11-34. Jan, S.V.S. 2007. Color atlas of skeletal landmark definitions. Churchill Livingstone, Elsevier, Philadelphia. Jin, Z. et al. 1993. Fluid film lubrication in natural hip joints. Tribology Series. Elsevier, pp.545-555. Jin, Z. et al. 1997. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 211(3), pp.247-256. Jin, Z. et al. 1999. An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 213(4), pp.317-327. Johnson, K.L. and Johnson, K.L. 1987. Contact mechanics. Cambridge university press. Jolles, B. and Zangger, P. 2002. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. The Journal of arthroplasty. 17(3), pp.282-288. Jolles, B.M. and Bogoch, E.R. 2003. Posterior versus lateral surgical approach for total hip arthroplasty in adults with osteoarthritis. Cochrane Database of Systematic Reviews. (4). Kadaba, M.P. et al. 1990. Measurement of lower extremity kinematics during level walking. Journal of orthopaedic research. 8(3), pp.383-392. Kang, L. et al. 2008a. Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure. 335 | P a g e Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 222(7), pp.1049-1064. Kang, L. et al. 2006. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 220(1), pp.33-46. Kang, L. et al. 2008b. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE. Journal of biomechanics. 41(2), pp.340-346. Kassi, J.-P. et al. 2005. Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro. Journal of biomechanics. 38(5), pp.1143-1154. Katta, J. et al. 2008a. Biotribology of articular cartilage—a review of the recent advances. Medical engineering & physics. 30(10), pp.1349-1363. Katta, J. et al. 2008b. Friction and wear of native and GAG deficient articular cartilage. In: World Biomaterials Congress, p.1191. Keller, T.S. et al. 1996. Relationship between vertical ground reaction force and speed during walking, slow jogging, and running. Clinical biomechanics. 11(5), pp.253-259. Khanna, V. et al. 2014. Cartilage restoration of the hip using fresh osteochondral allograft: resurfacing the potholes. The bone & joint journal. 96(11_Supple_A), pp.11-16. Kim, Y.-H. et al. 2016. Long-term results of third-generation ceramic-on-ceramic bearing cementless total hip arthroplasty in young patients. The Journal of arthroplasty. 31(11), pp.2520-2524. Knight, L. et al. 2005. Influence of cross-shear on the wear of polyethylene: A finite element study. Transactions of the Orthopaedic Research Society. p0987. Kostamo, T. et al. 2009. No difference in gender-specific hip replacement outcomes. Clinical orthopaedics and related research. 467(1), pp.135-140. Kotzar, G. et al. 1995. Torsional loads in the early postoperative period following total hip replacement. Journal of Orthopaedic Research. 13(6), pp.945-955. Kotzar, G. et al. 1991. Telemeterized in vivo hip joint force data: a report on two patients after total hip surgery. Journal of Orthopaedic Research. 9(5), pp.621-633. Kubo, T. et al. 2015. Hip arthroscopic osteochondral autologous transplantation for treating osteochondritis dissecans of the femoral head. Arthroscopy techniques. 4(6), pp.e675-e680. Kuhn, M. et al. 2013. Total hip arthroplasty in patients 50 years or less: do we improve activity profiles? The Journal of arthroplasty. 28(5), pp.872-876. Kuntze, G. et al. 2010. A biomechanical analysis of common lunge tasks in badminton. Journal of sports sciences. 28(2), pp.183-191. Kurtz, S.M. 2009. UHMWPE Biomaterials Handbook. Oxford: Elsevier, Academic Press. Kurtz, S.M. et al. 2009. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clinical Orthopaedics and Related Research®. 467(10), pp.2606-2612. 336 | P a g e Kwon, Y.-M. et al. 2010. Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours. The Journal of bone and joint surgery. British volume. 92(3), pp.356-361. Kwon, Y.-M. et al. 2012. In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours. Bone & joint research. 1(4), pp.42-49. Kyriazis, V. and Rigas, C. 2002. Temporal gait analysis of hip osteoarthritic patients operated with cementless hip replacement. Clinical Biomechanics. 17(4), pp.318-321. Lamontagne, M. et al. 2012. Lower‐limb joint mechanics after total hip arthroplasty during sitting and standing tasks. Journal of Orthopaedic Research. 30(10), pp.1611-1617. Lancaster, J. 1973. Dry bearings: a survey of materials and factors affecting their performance. Tribology. 6(6), pp.219-251. Learmonth, I.D. et al. 2007. The operation of the century: total hip replacement. The Lancet. 370(9597), pp.1508-1519. Lees, A. and Hurley, C. 1995. 29 Forces in a badminton lunge movement. Science and racket sports. p186. Leslie, E. et al. 2001. Age-related differences in physical activity levels of young adults. Medicine and science in sports and exercise. 33(2), pp.255-258. Lewinnek, G.E. et al. 1978. Dislocations after total hip-replacement arthroplasties. The Journal of bone and joint surgery. American volume. 60(2), pp.217-220. Lewis, C.L. and Sahrmann, S.A. 2015. Effect of posture on hip angles and moments during gait. Manual therapy. 20(1), pp.176-182. Li, J. et al. 2015. Unilateral total hip replacement patients with symptomatic leg length inequality have abnormal hip biomechanics during walking. Clinical Biomechanics. 30(5), pp.513-519. Li, J. et al. 2014. Hip contact forces in asymptomatic total hip replacement patients differ from normal healthy individuals: implications for preclinical testing. Clinical Biomechanics. 29(7), pp.747-751. Lipshitz, H. et al. 1980. In vitro studies of the wear of articular cartilage—III. The wear characteristics of chemically modified articular cartilage when worn against a highly polished characterized stainless steel surface. Journal of biomechanics. 13(5), pp.423-436. Lipshitz, H. and Glimcher, M. 1975. In vitro wear of articular cartilage. The Journal of bone and joint surgery. American volume. 57(4), pp.527-534. Lipshitz, H. and Glimcher, M.N.J. 1976. Changes in the hexosamine content and swelling ratio of articular cartilage as functions of depth from the surface. The Journal of bone and joint surgery. American volume. 58(8), pp.1149-1153. Liu, F. et al. 2006. Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 220(6), pp.695-704. Liu, Y. et al. 2017. Recent progress in cartilage tissue engineering—our experience and future directions. Engineering. 3(1), pp.28-35. 337 | P a g e Livermore, J. et al. 1990. Effect of femoral head size on wear of the polyethylene acetabular component. The Journal of bone and joint surgery. American volume. 72(4), pp.518-528. Lombardi Jr, A.V. et al. 2000. An in vivo determination of total hip arthroplasty pistoning during activity. The Journal of Arthroplasty. 15(6), pp.702-709. Lu, X. et al. 2006. The Stribeck curve: experimental results and theoretical prediction. Journal of tribology. 128(4), pp.789-794. Lund et al. 2019. AnyPyTools: A Python package for reproducible research with the AnyBody Modeling System. Journal of Open Source Software. 4(33), p1108. Lunn, D.E. et al. 2019. Hip kinematics and kinetics in total hip replacement patients stratified by age and functional capacity. Journal of Biomechanics. Lunn, D.E. et al. 2016. Basic biomechanics of the hip. Orthopaedics and Trauma. 30(3), pp.239-246. Lynn, S.K. and Noffal, G.J. 2012. Lower extremity biomechanics during a regular and counterbalanced squat. The Journal of Strength & Conditioning Research. 26(9), pp.2417-2425. Macdonald, S.J. et al. 2003. Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clinical Orthopaedics and Related Research®. 406(1), pp.282-296. Mahoney, O.M. 1990. Unsatisfactory results with a ceramic total hip prosthesis. The Journal of bone and joint surgery. American volume. 72(5), pp.663-671. Mak, M. et al. 2002. Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 216(6), pp.403-408. Maldonado, D.R. et al. 2018. Fresh Femoral Head Osteochondral Allograft Transplantation for Treating Osteochondritis Dissecans of the Femoral Head. Arthroscopy techniques. 7(4), pp.e331-e335. Manders, C. et al. 2008. Validation of musculoskeletal gait simulation for use in investigation of total hip replacement. Journal of Biomechanics. 41, pS488. Masonis, J.L. and Bourne, R.B. 2002. Surgical approach, abductor function, and total hip arthroplasty dislocation. Clinical Orthopaedics and Related Research (1976-2007). 405, pp.46-53. Mathieson, A. 2000. NICE issues guidance on hips. The Journal of Perioperative Practice. 10(6), p285. Matthies, A. et al. 2011. Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing. The Journal of bone and joint surgery. British volume. 93(3), pp.307-314. McConnell, T.H. and Hull, K.L. 2011. Human form human function: Essentials of anatomy and physiology. 1st ed. Baltimore, MD: Lippincott Williams & Wilkins. McCrory, J.L. et al. 2001. Vertical ground reaction forces: objective measures of gait following hip arthroplasty. Gait & posture. 14(2), pp.104-109. McGrory, B.J. et al. 1995. Participation in sports after hip and knee arthroplasty: review of literature and survey of surgeon preferences. In: Mayo Clinic Proceedings: Elsevier, pp.342-348. 338 | P a g e McKee, G. 1970. 10 Development of Total Prosthetic Replacement of the Hip. Clinical Orthopaedics and Related Research®. 72, pp.85-103. Meftah, M. et al. 2013. A novel method for accurate and reproducible functional cup positioning in total hip arthroplasty. The Journal of arthroplasty. 28(7), pp.1200-1205. Meira, E.P. and Zeni, J. 2014. Sports participation following total hip arthroplasty. International journal of sports physical therapy. 9(6), p839. Mellon, S. et al. 2011. The effect of motion patterns on edge-loading of metal-on-metal hip resurfacing. Medical engineering & physics. 33(10), pp.1212-1220. Meneghini, R.M. et al. 2006. Muscle damage during MIS total hip arthroplasty: Smith-Peterson versus posterior approach. Clinical Orthopaedics and Related Research®. 453, pp.293-298. Moisio, K.C. et al. 2003. Normalization of joint moments during gait: a comparison of two techniques. Journal of Biomechanics. 36, pp.599-603. Mollon, B. et al. 2013. The clinical status of cartilage tissue regeneration in humans. Osteoarthritis and cartilage. 21(12), pp.1824-1833. Moretti, V.M. and Post, Z.D. 2017. Surgical approaches for total hip arthroplasty. Indian journal of orthopaedics. 51(4), p368. Morlock, M. et al. 2001. Duration and frequency of every day activities in total hip patients. Journal of biomechanics. 34(7), pp.873-881. Mow, V. and Ateshian, G. 1997. In Lubrication and Wear of Diarthrodial Joints: Basic Orthopaedic Biomechanics; Mow, VC; Hayes, WC, Eds. Lippincott-Raven, Philadelphia. Mow, V.C. et al. 1993. Biomechanics of diarthrodial joints: a review of twenty years of progress. Journal of biomechanical engineering. 115(4B), pp.460-467. Mulholland, S.J. and Wyss, U.P. 2001. Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. International Journal of Rehabilitation Research. 24(3), pp.191-198. Müller, M. et al. 2011. Randomized controlled trial of abductor muscle damage in relation to the surgical approach for primary total hip replacement: minimally invasive anterolateral versus modified direct lateral approach. Archives of orthopaedic and trauma surgery. 131(2), pp.179-189. Murray, M. et al. 1975. Kinesiology after McKee-Farrar total hip replacement. A two-year follow-up of one hundred cases. The Journal of bone and joint surgery. American volume. 57(3), pp.337-342. Murray, M. et al. 1972. Kinesiologic Measurements of Functional Performance Before and After Mckee-farrar Total Hip Replacement: A Study Of Thirty Patients With Rheumatoid Arthritis, Osteoarthritis, Or Avascular Necrosis Of The Femoral Head. JBJS. 54(2), pp.237-256. Nadzadi, M.E. et al. 2003. Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. Journal of biomechanics. 36(4), pp.577-591. Nagura, T. et al. 2002. Mechanical loads at the knee joint during deep flexion. Journal of Orthopaedic Research. 20(4), pp.881-886. 339 | P a g e Nevelos, J. et al. 2001. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. The Journal of bone and joint surgery. British volume. 83(4), pp.598-603. NHS. 2019. Hip replacement. [Online]. Available from: https://www.nhs.uk/conditions/hip-replacement/. NICE. 2002. The clinical effectiveness and cost effectiveness of metal on metal hip resurfacing. [Online]. [Accessed 26 October 2016]. Available from: http://guidance.nice.org.uk/TA44. Nigg, B.M. et al. 1999. Biomechanics of the musculo-skeletal system. Wiley New York. NJR. 2018. National Joint Registry Centre. [Online]. [Accessed 26 October 2016]. Available from: www.njrcentre.org.uk. O'Connor, D.O. et al. 1996. In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair‐climbing. Journal of orthopaedic research. 14(5), pp.769-777. O'Connor, J.D. et al. 2018. Long-term hip loading in unilateral total hip replacement patients is no different between limbs or compared to healthy controls at similar walking speeds. Journal of biomechanics. 80, pp.8-15. Oladeji, L.O. et al. 2018. Large fresh osteochondral allografts for the hip: growing the evidence. HIP International. 28(3), pp.284-290. Oonishi, H. et al. 2004. Alumina hip joints characterized by run‐in wear and steady‐state wear to 14 million cycles in hip‐simulator model. Journal of Biomedical Materials Research Part A: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for Biomaterials. 70(4), pp.523-532. Oonishi, H. et al. 1998. Retrieved total hip prostheses. Part I: the effects of cup thickness, head sizes and fusion defects on wear. Journal of Materials Science: Materials in Medicine. 9(7), pp.393-401. Paul, J. 1966. Paper 8: forces transmitted by joints in the human body. In: Proceedings of the Institution of Mechanical Engineers, Conference Proceedings: SAGE Publications Sage UK: London, England, pp.8-15. Pearsall, D. and Costigan, P. 1999. The effect of segment parameter error on gait analysis results. Gait & Posture. 9(3), pp.173-183. Perron, M. et al. 2003. Assessing advanced locomotor recovery after total hip arthroplasty with the timed stair test. Clinical rehabilitation. 17(7), pp.780-786. Perron, M. et al. 2000. Three-dimensional gait analysis in women with a total hip arthroplasty. Clinical Biomechanics. 15(7), pp.504-515. Peters, A. et al. 2010. Quantification of soft tissue artifact in lower limb human motion analysis: a systematic review. Gait & posture. 31(1), pp.1-8. Pfirrmann, C.W. et al. 2005. Abductor tendons and muscles assessed at MR imaging after total hip arthroplasty in asymptomatic and symptomatic patients. Radiology. 235(3), pp.969-976. Prosser, G.H. et al. 2010. Outcome of primary resurfacing hip replacement: evaluation of risk factors for early revision: 12,093 replacements from the Australian Joint Registry. Acta orthopaedica. 81(1), pp.66-71. 340 | P a g e Queen, R.M. et al. 2013. Stair ascending and descending in hip resurfacing and large head total hip arthroplasty patients. The Journal of arthroplasty. 28(4), pp.684-689. Radin, E.L. and Paul, I.L. 1971. Response of joints to impact loading. I. In vitro wear. Arthritis & Rheumatism: Official Journal of the American College of Rheumatology. 14(3), pp.356-362. Ramamurti, B.S. et al. 1996. Loci of movement of selected points on the femoral head during normal gait: three-dimensional computer simulation. The Journal of arthroplasty. 11(7), pp.845-852. Riberto, M. et al. 2013. Setting up a human motion analysis laboratory: camera positioning for kinematic recording of gait. Int J Phys Med Rehabil. 1(131), p2. Ritter, M.A. and Meding, J.B. 1987. Total hip arthroplasty. Can the patient play sports again? Orthopedics. 10, pp.1447-52. Ritter, M.A. et al. 1983. Correlation of prosthetic femoral head size and/or design with longevity of total hip arthroplasty. Clinical orthopaedics and related research. (176), pp.252-257. Robertson, G. et al. 2013. Research methods in biomechanics, 2E. Human Kinetics. Roebroeck, M. et al. 1994. Biomechanics and muscular activity during sit-to-stand transfer. Clinical Biomechanics. 9(4), pp.235-244. Rydell, N.W. 1966. Forces acting on the femoral head-prosthesis: a study on strain gauge supplied prostheses in living persons. Acta Orthopaedica Scandinavica. 37(sup88), pp.1-132. Saikko, V. 2014. In vitro wear simulation on the RandomPOD wear testing system as a screening method for bearing materials intended for total knee arthroplasty. Journal of biomechanics. 47(11), pp.2774-2778. Saikko, V. and Calonius, O. 2002. Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. Journal of Biomechanics. 35(4), pp.455-464. Saikko, V. et al. 2003. Effect of extent of motion and type of load on the wear of polyethylene in a biaxial hip simulator. Journal of Biomedical Materials Research Part B: Applied Biomaterials: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for Biomaterials. 65(1), pp.186-192. Saikko, V.O. 1996. A three-axis hip joint simulator for wear and friction studies on total hip prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 210(3), pp.175-185. Schache, A.G. et al. 2001. The effect of differing Cardan angle sequences on three dimensional lumbo-pelvic angular kinematics during running. Medical engineering & physics. 23(7), pp.495-503. Scheerlinck, T. 2014. Cup positioning in total hip arthroplasty. Acta Orthop Belg. 80(03), pp.336-347. Schmalzried, T.P. 2012. Patient activity and hip wear. In: Seminars in Arthroplasty: Elsevier, pp.193-196. Schmalzried, T.P. et al. 1996. Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces. The Journal of arthroplasty. 11(3), pp.322-331. 341 | P a g e Schmalzried, T.P. et al. 2000. Wear is a function of use, not time. Clinical Orthopaedics and Related Research (1976-2007). 381, pp.36-46. Schmalzried, T.P. et al. 1998. Quantitative assessment of walking activity after total hip or knee replacement. JBJS. 80(1), pp.54-9. Schmidt, M. et al. 1996. Cobalt chromium molybdenum metal combination for modular hip prostheses. Clinical Orthopaedics and Related Research®. 329, pp.S35-S47. Schoenfeld, B.J. 2010. Squatting kinematics and kinetics and their application to exercise performance. The Journal of Strength & Conditioning Research. 24(12), pp.3497-3506. Scholes, S. and Unsworth, A. 2000. Comparison of friction and lubrication of different hip prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 214(1), pp.49-57. Schreven, S. et al. 2015. Optimising filtering parameters for a 3D motion analysis system. Journal of Electromyography and Kinesiology. 25(5), pp.808-814. Schwachmeyer, V. et al. 2013. In vivo hip joint loading during post-operative physiotherapeutic exercises. PLoS One. 8(10), pe77807. Seagrave, K.G. et al. 2017. Acetabular cup position and risk of dislocation in primary total hip arthroplasty: a systematic review of the literature. Acta orthopaedica. 88(1), pp.10-17. Sechriest II, V.F. et al. 2007. Activity level in young patients with primary total hip arthroplasty: a 5-year minimum follow-up. The Journal of arthroplasty. 22(1), pp.39-47. Sedel, L. et al. 1990. Alumina-on-alumina hip replacement. Results and survivorship in young patients. The Journal of bone and joint surgery. British volume. 72(4), pp.658-663. Selbie, W.S. et al. 2014. Three-dimensional kinetics. Research methods in biomechanics. pp.151-176. Shaju, K. et al. 2005. The 22-mm vs the 32-mm femoral head in cemented primary hip arthroplasty: long-term clinical and radiological follow-up study. The Journal of arthroplasty. 20(7), pp.903-908. Shon, W.Y. et al. 2005. Impingement in total hip arthroplasty: a study of retrieved acetabular components. The Journal of arthroplasty. 20(4), pp.427-435. Sieber, H.-P. et al. 1999. Analysis of 118 second-generation metal-on-metal retrieved hip implants. The Journal of bone and joint surgery. British volume. 81(1), pp.46-50. Silva, M. et al. 2002. Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity. The Journal of arthroplasty. 17(6), pp.693-697. Simon, S.R. 2004. Quantification of human motion: gait analysis—benefits and limitations to its application to clinical problems. Journal of biomechanics. 37(12), pp.1869-1880. Sinclair, J. et al. 2012. Influence of the helical and six available Cardan sequences on 3D ankle joint kinematic parameters. Sports Biomechanics. 11(3), pp.430-437. Skaggs, D.L. et al. 2000. Variability in gait analysis interpretation. Journal of Pediatric Orthopaedics. 20(6), pp.759-764. 342 | P a g e Smith, A.J. et al. 2012. Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales. The Lancet. 379(9822), pp.1199-1204. Smith, S. et al. 2001. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 215(2), pp.161-170. Smith, S. and Unsworth, A. 2000. Simplified motion and loading compared to physiological motion and loading in a hip joint simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 214(3), pp.233-238. Smith, S. and Unsworth, A. 2001. A five-station hip joint simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 215(1), pp.61-64. Stagni, R. et al. 2000. Effects of hip joint centre mislocation on gait analysis results. Journal of biomechanics. 33(11), pp.1479-1487. Stansfield, B. et al. 2003. Direct comparison of calculated hip joint contact forces with those measured using instrumented implants. An evaluation of a three-dimensional mathematical model of the lower limb. Journal of biomechanics. 36(7), pp.929-936. Stewart, T. 2010. Tribology of artificial joints. Orthopaedics and Trauma. 24(6), pp.435-440. Stewart, T. et al. 1997. Friction of composite cushion bearings for total knee joint replacements under adverse lubrication conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 211(6), pp.451-465. Stolk, J. et al. 2002. Stair climbing is more detrimental to the cement in hip replacement than walking. Clinical Orthopaedics and Related Research®. 405, pp.294-305. Sum, J. et al. 1998. Effects of normalization on joint moments during level walking. Gait & Posture. 7, p184. Swanson, E.A. et al. 2009. Activity recommendations after total hip and knee arthroplasty: a survey of the American Association for Hip and Knee Surgeons. The Journal of arthroplasty. 24(6), pp.120-126. Sychterz, C.J. et al. 1999. Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in. JBJS. 81(6), pp.821-830. Talis, V. et al. 2008. Asymmetric leg loading during sit-to-stand, walking and quiet standing in patients after unilateral total hip replacement surgery. Clinical Biomechanics. 23(4), pp.424-433. Temple, J. 2004. Total hip replacement. Nursing Standard (through 2013). 19(3), p44. Thier, S. et al. 2017. Arthroscopic autologous chondrocyte implantation in the hip for the treatment of full-thickness cartilage defects: A case series of 29 patients and review of the literature. SICOT-J. 3. 343 | P a g e Tirico, L.E. et al. 2018. Modern Osteochondral Allograft Transplantation: The “Gold Standard” for Femoral Condyle Cartilage Repair? Orthopaedic journal of sports medicine. 6(3_suppl), p2325967118S00004. Turell, M. et al. 2003. Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene. Wear. 255(7-12), pp.1034-1039. Underwood, R.J. et al. 2012. Edge loading in metal-on-metal hips: low clearance is a new risk factor. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 226(3), pp.217-226. van Arkel, R.J. et al. 2013. Hip abduction can prevent posterior edge loading of hip replacements. Journal of Orthopaedic Research. 31(8), pp.1172-1179. Van der Weegen, W. et al. 2011. Survival of metal-on-metal hip resurfacing arthroplasty: a systematic review of the literature. The Journal of bone and joint surgery. British volume. 93(3), pp.298-306. VanLaanen, J.B. 2013. Validation of a cross-shear model for ultra-high molecular weight polyethylene (UHMWPE) wear. Master of Science thesis, Colorado School of Mines. Vassiliou, K. et al. 2007. Laboratory studies on the tribology of hard bearing hip prostheses: ceramic on ceramic and metal on metal. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 221(1), pp.11-20. Vaughan-Graham, J. et al. 2019. Transitions sit to stand and stand to sit in persons post-stroke: Path of centre of mass, pelvic and limb loading–A pilot study. Clinical Biomechanics. 61, pp.22-30. Visuri, T. and Honkanen, R. 1978. The influence of total hip replacement on selected activities of daily living and on the use of domestic aid. Scandinavian journal of rehabilitation medicine. 10(4), pp.221-225. Visuri, T. and Honkanen, R. 1980. Total hip replacement: its influence on spontaneous recreation exercise habits. Arch Phys Med Rehabil. 61(7), pp.325-8. Walter, W.L. et al. 2004. Edge loading in third generation alumina ceramic-on-ceramic bearings: Stripe wear1. The Journal of arthroplasty. 19(4), pp.402-413. Wang, A. 2001. A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding. Wear. 248(1-2), pp.38-47. Wang, A. et al. 1998. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribology International. 31(1-3), pp.17-33. Wang, A. et al. 1997b. The significance of nonlinear motion in the wear screening of orthopaedic implant materials. Journal of Testing and Evaluation. 25(2), pp.239-245. Wang, A. et al. 1996. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 210(3), pp.141-155. Wang, A. et al. 1997a. Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene. Wear. 203, pp.230-241. Wang, Y. et al. 2006. Development of a set of stribeck curves for conformal contacts of rough surfaces. Tribology Transactions. 49(4), pp.526-535. 344 | P a g e Wannop, J.W. et al. 2012. Normalization of ground reaction forces, joint moments, and free moments in human locomotion. Journal of Applied Biomechanics. 28(6), pp.665-76. Wehner, T. et al. 2009. Internal loads in the human tibia during gait. Clinical Biomechanics. 24(3), pp.299-302. Widhalm, R. et al. 1990. Is there greater danger of sports injury or osteoporosis caused by inactivity in patients with hip prosthesis? Sequelae for long-term stability of prosthesis anchorage. Zeitschrift fur Orthopadie und ihre Grenzgebiete. 128(2), pp.139-143. Winter, D.A. 1984. Kinematic and kinetic patterns in human gait: variability and compensating effects. Human movement science. 3(1-2), pp.51-76. Winter, D.A. 2009. Biomechanics and motor control of human movement. John Wiley & Sons. Wylde, V. et al. 2008. Return to sport after joint replacement. The Journal of bone and joint surgery. British volume. 90(7), pp.920-923. Yoshida, H. et al. 2006. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living. Journal of biomechanics. 39(11), pp.1996-2004. Yu, B. et al. 1999. Estimate of the optimum cutoff frequency for the Butterworth low-pass digital filter. Journal of Applied Biomechanics. 15(3), pp.318-329. Yusuf, H.R. et al. 1996. Leisure-time physical activity among older adults: United States, 1990. Archives of internal medicine. 156(12), pp.1321-1326. Zhou, Y. et al. 1997. Start up and steady state friction of alumina against alumina. Wear. 210(1-2), pp.112-119. Zywiel, M.G. et al. 2011. State of the art in hard-on-hard bearings: how did we get here and what have we achieved? Expert review of medical devices. 8(2), pp.187-207."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.805369"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["484643"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/26885/1/Layton_Thesis_2020.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Total hip arthroplasty is one of the most successful and innovative medical procedures developed during the 20th century. Success post-op has been shown to decrease for younger, more active patients when compared to those who are older and less active, raising concerns surrounding the reasons behind the increased risk of prosthesis failure for some individuals. Sliding distance, cross-shear, load and edge loading are important factors when determining potential wear rates at the hip. Global and local hip biomechanics were calculated for eighteen healthy subjects, completing thirteen common daily activities. Results showed variation in cross-shear motion and hip reaction forces between individuals and across activities. Variation in motion paths and loading, between and within activities, suggested variation in the fluid film thickness and corresponding lubrication regimes at the joint. Walking tasks showed high levels of cross-shear and the potential for excessive wear both at initial contact and heel-off. More linear activities, such as sitting and standing, showed low cross-shear alongside a potential risk of posterior edge loading. Tribological discrepancies were shown between hip simulator input data (ISO) and measured walking data, with the ISO cycle potentially underestimating cross-shear wear at initial contact, during walking. Results provide detailed data that may facilitate improvements in the reliability of pre-clinical testing for hip prostheses and tissue engineered cartilage substitution. The data indicates that durability testing standards should consider incorporating a range of activities, rather than just walking, and aim to represent the variability shown between individuals. Results also provide evidence for determining the appropriateness of specific activities/ rehabilitation for post-operative total hip replacement patients."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Understanding Movement and its Influence on Tribology of the Human Hip"]}]}],"canonical_facts":{"dc:contributor.advisor":["Stewart, Todd","Messenger, Neil"],"dc:contributor.sponsor":["UK Engineering and Physical Sciences Research Council (EPSRC)"],"dc:creator":["Layton, Robin B."],"dc:date":["2020-04"],"dc:date.issued":["2020-04"],"dc:description.abstract":["Total hip arthroplasty is one of the most successful and innovative medical procedures developed during the 20th century. Success post-op has been shown to decrease for younger, more active patients when compared to those who are older and less active, raising concerns surrounding the reasons behind the increased risk of prosthesis failure for some individuals. Sliding distance, cross-shear, load and edge loading are important factors when determining potential wear rates at the hip. Global and local hip biomechanics were calculated for eighteen healthy subjects, completing thirteen common daily activities. Results showed variation in cross-shear motion and hip reaction forces between individuals and across activities. Variation in motion paths and loading, between and within activities, suggested variation in the fluid film thickness and corresponding lubrication regimes at the joint. Walking tasks showed high levels of cross-shear and the potential for excessive wear both at initial contact and heel-off. More linear activities, such as sitting and standing, showed low cross-shear alongside a potential risk of posterior edge loading. Tribological discrepancies were shown between hip simulator input data (ISO) and measured walking data, with the ISO cycle potentially underestimating cross-shear wear at initial contact, during walking. Results provide detailed data that may facilitate improvements in the reliability of pre-clinical testing for hip prostheses and tissue engineered cartilage substitution. The data indicates that durability testing standards should consider incorporating a range of activities, rather than just walking, and aim to represent the variability shown between individuals. Results also provide evidence for determining the appropriateness of specific activities/ rehabilitation for post-operative total hip replacement patients."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.805369"],"dc:identifier.grantnumber":["484643"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/26885/1/Layton_Thesis_2020.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/26885/"],"dc:relation.references":["Abdel, M. et al. 2016a. What is the lifetime risk of revision for patients undergoing total hip arthroplasty? a 40-year observational study of patients treated with the Charnley cemented total hip arthroplasty. The bone & joint journal. 98(11), pp.1436-1440. Abdel, M.P. et al. 2016b. What safe zone? The vast majority of dislocated THAs are within the Lewinnek safe zone for acetabular component position. Clinical Orthopaedics and Related Research®. 474(2), pp.386-391. Adams, J. and Hamblen, D. 2001. Outline of Orthopaedics. Thirteenth ed. London: Churchill Livingstone. Al-Hajjar, M. et al. 2013. Wear of 36-mm BIOLOX® delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 227(5), pp.535-542. Al‐Hajjar, M. et al. 2017. Wear of composite ceramics in mixed‐material combinations in total hip replacement under adverse edge loading conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 105(6), pp.1361-1368. Al‐Hajjar, M. et al. 2013. Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge‐loading conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 101(2), pp.213-222. Al‐Hajjar, M. et al. 2010. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic‐on‐ceramic total hip replacement. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 95(2), pp.263-268. AnyBody. 2019. Any Tutorials. [Online]. Available from: https://anyscript.org/tutorials/index.html. Archard, J. 1953. Contact and rubbing of flat surfaces. Journal of applied physics. 24(8), pp.981-988. Banaszkiewicz, P.A. 2014. Dislocations after total hip-replacement arthroplasties. In Classic Papers in Orthopaedics. London: Springer. Barbour, P. et al. 1997. The influence of stress conditions on the wear of UHMWPE for total joint replacements. Journal of materials science: Materials in medicine. 8(10), pp.603-611. Barbour, P. et al. 1999. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 213(6), pp.455-467. Barbour, P. et al. 2000. A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 214(6), pp.569-576. Barnett, J. 2009. Motions in Space: The Motions of Femoral Heads over Acetabular Cups. MSc thesis, University of Leeds. 329 | P a g e Barré, A. et al. 2015. Soft tissue artifact distribution on lower limbs during treadmill gait: influence of skin markers' location on cluster design. Journal of biomechanics. 48(10), pp.1965-1971. Barry, J.J. et al. 2018. Recovery and outcomes of direct anterior approach total hip arthroplasty. Annals of Joint. 3(6). Bartel, D. et al. 1985. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. Journal of Biomechanical Engineering. 107(3), pp.193-199. Beaupre, L.A. et al. 2013. A randomized trial of ceramic-on-ceramic bearing versus ceramic-on-crossfire-polyethylene bearing in total hip arthroplasty: five-year outcomes. The Journal of arthroplasty. 28(3), pp.485-489. Bell, A.L. et al. 1989. Prediction of hip joint centre location from external landmarks. Human Movement Science. 8(1), pp.3-16. Bell, A.L. et al. 1990. A comparison of the accuracy of several hip center location prediction methods. Journal of biomechanics. 23(6), pp.617-621. Bennett, D. et al. 2008. The influence of wear paths produced by hip replacement patients during normal walking on wear rates. Journal of Orthopaedic Research. 26(9), pp.1210-1217. Bennett, D. et al. 2002. The influence of shape and sliding distance of femoral head movement loci on the wear of acetabular cups in total hip arthroplasty. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 216(6), pp.393-402. Bennett, D.B. et al. 2000. Movement loci of selected points on the femoral head for individual total hip arthroplasty patients using three-dimensional computer simulation. The Journal of arthroplasty. 15(7), pp.909-915. Bergmann, G. et al. 2001. Hip contact forces and gait patterns from routine activities. Journal of biomechanics. 34(7), pp.859-871. Bergmann, G. et al. 1993. Hip joint loading during walking and running, measured in two patients. Journal of biomechanics. 26(8), pp.969-990. Bergmann, G. et al. 1995. Is staircase walking a risk for the fixation of hip implants? Journal of biomechanics. 28(5), pp.535-553. Bini, R. et al. 2019. Biomechanical and physiological responses to electrically assisted cycling during simulated mail delivery. Applied Ergonomics. 75, pp.243-249. Bosker, B. et al. 2007. Poor accuracy of freehand cup positioning during total hip arthroplasty. Archives of orthopaedic and trauma surgery. 127(5), pp.375-379. Bowsher, J. and Shelton, J. 2001. A hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions. Wear. 250(1-12), pp.167-179. Bozic, K.J. et al. 2010. Risk of complication and revision total hip arthroplasty among Medicare patients with different bearing surfaces. Clinical Orthopaedics and Related Research®. 468(9), pp.2357-2362. Bragdon, C. et al. 1996. The importance of multidirectional motion on the wear of polyethylene. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 210(3), pp.157-165. 330 | P a g e Brand, R.A. et al. 1994. Comparison of hip force calculations and measurements in the same patient. The Journal of arthroplasty. 9(1), pp.45-51. Bremer, A. et al. 2011. Soft-tissue changes in hip abductor muscles and tendons after total hip replacement: comparison between the direct anterior and the transgluteal approaches. The Journal of bone and joint surgery. British volume. 93(7), pp.886-889. Brown, M. et al. 1980. Walking efficiency before and after total hip replacement. Physical therapy. 60(10), pp.1259-1263. Buckwalter, J.A. et al. 2000. Orthopaedic basic science : biology and biomechanics of the musculoskeletal system. Rosemont, IL: American Academy of Orthopaedic Surgeons. Budenberg, S. et al. 2012. Contact surface motion paths associated with leg length inequality following unilateral total hip replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 226(12), pp.968-974. C-Motion. 2018. Visual3D Tutorials. [Online]. [Accessed 13 September]. Available from: www.c-motion.com. Calonius, O. and Saikko, V. 2002. Slide track analysis of eight contemporary hip simulator designs. Journal of Biomechanics. 35(11), pp.1439-1450. Calonius, O. and Saikko, V. 2003. Force track analysis of contemporary hip simulators. Journal of biomechanics. 36(11), pp.1719-1726. Cappozzo, A. et al. 1995. Position and orientation in space of bones during movement: anatomical frame definition and determination. Clinical biomechanics. 10(4), pp.171-178. Carbone, V. et al. 2015. TLEM 2.0–A comprehensive musculoskeletal geometry dataset for subject-specific modeling of lower extremity. Journal of biomechanics. 48(5), pp.734-741. Chahal, J. et al. 2013. Managing the patient with failed cartilage restoration. Sports medicine and arthroscopy review. 21(2), pp.62-68. Chao, E. et al. 1983. Normative data of knee joint motion and ground reaction forces in adult level walking. Journal of biomechanics. 16(3), pp.219-233. Charnley, J. 1970. 2 Total Hip Replacement by Low-Friction Arthroplasty. Clinical Orthopaedics and Related Research®. 72, pp.7-21. Charnley, J. et al. 1969. The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Medical and biological engineering. 7(1), pp.31-39. Chatterji, U. et al. 2004. Effect of total hip arthroplasty on recreational and sporting activity. ANZ journal of surgery. 74(6), pp.446-449. Choi, B.C. et al. 2007. Daily step goal of 10,000 steps: a literature review. Clinical & Investigative Medicine. 30(3), pp.146-151. Clifford, P.E. and Mallon, W.J. 2005. Sports after total joint replacement. Clinics in sports medicine. 24(1), pp.175-186. Cooper, J. et al. 1993. Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene. Wear. 162, pp.378-384. 331 | P a g e Crombie, I.K. et al. 2004. Why older people do not participate in leisure time physical activity: a survey of activity levels, beliefs and deterrents. Age and ageing. 33(3), pp.287-292. Crowninshield, R. et al. 1978. A biomechanical investigation of the human hip. Journal of biomechanics. 11(1), pp.79-85. D’antonio, J.A. et al. 2012. Ceramic bearings for total hip arthroplasty have high survivorship at 10 years. Clinical Orthopaedics and Related Research®. 470(2), pp.373-381. Damm, P. et al. 2013a. Friction in total hip joint prosthesis measured in vivo during walking. PLoS One. 8(11), pe78373. Damm, P. et al. 2013b. In vivo hip joint loads during three methods of walking with forearm crutches. Clinical Biomechanics. 28(5), pp.530-535. Davy, D. et al. 1988. Telemetric force measurements across the hip after total arthroplasty. The Journal of bone and joint surgery. American volume. 70(1), pp.45-50. De Pieri, E. et al. 2019. Patient Characteristics Affect Hip Contact Forces during Gait. Osteoarthritis and Cartilage. Delasotta, L.A. et al. 2012. What are young patients doing after hip reconstruction? The Journal of arthroplasty. 27(8), pp.1518-1525. e2. Dewolf, A.H. et al. 2018. Kinematic patterns while walking on a slope at different speeds. Journal of Applied Physiology. Donahue, G.S. et al. 2016. Are females at greater risk for revision surgery after hip resurfacing arthroplasty with the articular surface replacement prosthesis? Clinical Orthopaedics and Related Research®. 474(10), pp.2257-2265. Dorlot, J.-M. 1992. Long-term effects of alumina components in total hip prostheses. Clinical orthopaedics and related research. (282), pp.47-52. Dowson, D. and Jobbins, B. 1988. Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints. Engineering in medicine. 17(3), pp.111-117. Dressler, M.R. et al. 2011. Predicting wear of UHMWPE: Decreasing wear rate following a change in direction. Wear. 271(11-12), pp.2879-2883. Dubs, L. et al. 1983. Sport after total hip arthroplasty. Archives of orthopädic and traumatic Surgery. 101(3), pp.161-169. Dumbleton, J.H. et al. 2006. The basis for a second-generation highly cross-linked UHMWPE. Clinical orthopaedics and related research. 453, pp.265-271. Esposito, C. et al. 2012. Wear in alumina-on-alumina ceramic total hip replacements: a retrieval analysis of edge loading. The Journal of bone and joint surgery. British volume. 94(7), pp.901-907. Evans, J.T. et al. 2019. How long does a hip replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up. The Lancet. 393(10172), pp.647-654. Ewen, A.M. et al. 2012. Post-operative gait analysis in total hip replacement patients—a review of current literature and meta-analysis. Gait & posture. 36(1), pp.1-6. 332 | P a g e Farrokhi, S. et al. 2008. Trunk position influences the kinematics, kinetics, and muscle activity of the lead lower extremity during the forward lunge exercise. journal of orthopaedic & sports physical therapy. 38(7), pp.403-409. Field, A. 2013. Discovering statistics using IBM SPSS statistics. sage. Firkins, P. et al. 2001. Quantitative analysis of wear and wear debris from metal‐on‐metal hip prostheses tested in a physiological hip joint simulator. Bio-Medical Materials and Engineering. 11(2), pp.143-157. Flanagan, S. et al. 2003. Squatting exercises in older adults: kinematic and kinetic comparisons. Medicine and science in sports and exercise. 35(4), p635. Flanagan, S.P. et al. 2004. Biomechanical attributes of lunging activities for older adults. Journal of strength and conditioning research/National Strength & Conditioning Association. 18(3), p599. Forster, E. 2004. Predicting muscle forces in the human lower limb during locomotion. thesis, Universität Ulm. Foucher, K. et al. 1999. Gait adaptations in postoperative total hip replacement patients are associated with reduced hip contact forces. In: 23rd Annual Meeting of American Society of Biomechanics, Pittsburgh, Pennsylvania, pp.134-135. Foucher, K.C. 2016. Identifying clinically meaningful benchmarks for gait improvement after total hip arthroplasty. Journal of Orthopaedic Research. 34(1), pp.88-96. Foucher, K.C. et al. 2007. Preoperative gait adaptations persist one year after surgery in clinically well-functioning total hip replacement patients. Journal of biomechanics. 40(15), pp.3432-3437. Foucher, K.C. et al. 2008. Do gait adaptations during stair climbing result in changes in implant forces in subjects with total hip replacements compared to normal subjects? Clinical Biomechanics. 23(6), pp.754-761. Fox, A.S. 2018. Change-of-Direction Biomechanics: Is What’s Best for Anterior Cruciate Ligament Injury Prevention Also Best for Performance? Sports Medicine. pp.1-9. Franjcic, Z. and Wozniak, P.W. 2014. QualiWand: Towards Optimising Feedback for Motion Capture System Calibration. In: Graphics Interface 2014 Poster Session Proceedings, pp.5-6. Fumes, O. et al. 2001. Hip disease and the prognosis of total hip replacements: A review of 53 698 primary total hip replacements reported to the Norwegian arthroplasty register 1987-99. Journal of bone and joint surgery. British volume. 83(4), pp.579-586. Galante, J.O. and Rostoker, W. 1972. Wear in total hip prostheses: an experimental evaluation of candidate materials. Acta Orthopaedica Scandinavica. 43(sup145), pp.1-46. Galvin, A. et al. 2006. Wear of crosslinked polyethylene under different tribological conditions. Journal of Materials Science: Materials in Medicine. 17(3), pp.235-243. Geduldig, D. et al. 1976. Experimental investigations of dense alumina ceramic for hip and knee joint replacements. Engineering in Medicine. Springer, pp.434-445. Gholizadeh, H. et al. 2018. Transtibial amputee gait during slope walking with the unity suspension system. Gait & posture. 65, pp.205-212. 333 | P a g e Goldsmith, A. et al. 2000. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 214(1), pp.39-47. Goldsmith, A. et al. 2001. The effect of activity levels of total hip arthroplasty patients on socket penetration. The Journal of arthroplasty. 16(5), pp.620-627. Gomez, P.F. and Morcuende, J.A. 2005. Early attempts at hip arthroplasty: 1700s to 1950s. The Iowa orthopaedic journal. 25, p25. Granata, K.P. et al. 2000. Joint angular velocity in spastic gait and the influence of muscle-tendon lengthening. The Journal of bone and joint surgery. American volume. 82(2), p174. Griffith, M. et al. 1978. Socket wear in Charnley low friction arthroplasty of the hip. Clinical orthopaedics and related research. (137), pp.37-47. Gschwend, N. et al. 2000. Alpine and cross-country skiing after total hip replacement: 2 cohorts of 50 patients each, one active, the other inactive in skiing, followed for 5-10 years. Acta Orthopaedica Scandinavica. 71(3), pp.243-249. Gulgin, H. et al. 2009. Hip rotational velocities during the full golf swing. Journal of Sports Science and Medicine. 8(2), pp.296-9. Haberly, G. and Pavol, M. 2013. Hip loading during the squat exercise. Masters of science thesis, George Fox University. Hall, R. et al. 1996. Wear in retrieved Charnley acetabular sockets. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 210(3), pp.197-207. Hamill, J. et al. 1984. Ground reaction force symmetry during walking and running. Research Quarterly for Exercise and Sport. 55(3), pp.289-293. Hamill, J. and Knutzen, K.M. 2006. Biomechanical basis of human movement. Lippincott Williams & Wilkins. Hamrock, B.J. and Dowson, D. 1978. Elastohydrodynamic lubrication of elliptical contacts for materials of low elastic modulus I—fully flooded conjunction. Journal of Lubrication Technology. 100(2), pp.236-245. Hannouche, D. et al. 2016. Ceramic-on-ceramic THA implants in patients younger than 20 years. Clinical Orthopaedics and Related Research®. 474(2), pp.520-527. Harris, W.H. 1995. The problem is osteolysis. Clinical orthopaedics and related research. (311), pp.46-53. Hart, A. et al. 2013. Which factors determine the wear rate of large-diameter metal-on-metal hip replacements?: Multivariate analysis of two hundred and seventy-six components. JBJS. 95(8), pp.678-685. Healy, W.L. et al. 2008. Athletic activity after total joint arthroplasty. JBJS. 90(10), pp.2245-2252. Heller, M. et al. 2001. Musculo-skeletal loading conditions at the hip during walking and stair climbing. Journal of biomechanics. 34(7), pp.883-893. Hemmerich, A. et al. 2006. Hip, knee, and ankle kinematics of high range of motion activities of daily living. Journal of orthopaedic research. 24(4), pp.770-781. 334 | P a g e Herzog, W. et al. 1989. Asymmetries in ground reaction force patterns in normal human gait. Med Sci Sports Exerc. 21(1), pp.110-114. Higginson, G. 1978. Squeeze films between compliant solids. Wear. 46(2), pp.387-395. Horsman, M.K. 2007. The Twente lower extremity model. Consistent dynamic simulation of the human locomotor apparatus. Hua, X. et al. 2016. The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities. Medical engineering & physics. 38(6), pp.518-525. Huch, K. et al. 2005. Sports activities 5 years after total knee or hip arthroplasty: the Ulm Osteoarthritis Study. Annals of the rheumatic diseases. 64(12), pp.1715-1720. Hume, P.A. et al. 2005. The role of biomechanics in maximising distance and accuracy of golf shots. Sports medicine. 35(5), pp.429-449. Ingham, E. and Fisher, J. 2005. The role of macrophages in osteolysis of total joint replacement. Biomaterials. 26(11), pp.1271-1286. ISO. 2014. ISO 14242-1. Implants for surgery — Wear of total hip-joint prostheses — Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test. [Online]. [Accessed 10-06-2019]. Available from: https://www.iso.org/obp/ui/#iso:std:iso:14242:-1:ed-3:v1:en:fig:1. Jacobs, N. et al. 1972. Analysis of the vertical component of force in normal and pathological gait. Journal of Biomechanics. 5(1), pp.11-34. Jan, S.V.S. 2007. Color atlas of skeletal landmark definitions. Churchill Livingstone, Elsevier, Philadelphia. Jin, Z. et al. 1993. Fluid film lubrication in natural hip joints. Tribology Series. Elsevier, pp.545-555. Jin, Z. et al. 1997. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 211(3), pp.247-256. Jin, Z. et al. 1999. An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 213(4), pp.317-327. Johnson, K.L. and Johnson, K.L. 1987. Contact mechanics. Cambridge university press. Jolles, B. and Zangger, P. 2002. Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. The Journal of arthroplasty. 17(3), pp.282-288. Jolles, B.M. and Bogoch, E.R. 2003. Posterior versus lateral surgical approach for total hip arthroplasty in adults with osteoarthritis. Cochrane Database of Systematic Reviews. (4). Kadaba, M.P. et al. 1990. Measurement of lower extremity kinematics during level walking. Journal of orthopaedic research. 8(3), pp.383-392. Kang, L. et al. 2008a. Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure. 335 | P a g e Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 222(7), pp.1049-1064. Kang, L. et al. 2006. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 220(1), pp.33-46. Kang, L. et al. 2008b. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE. Journal of biomechanics. 41(2), pp.340-346. Kassi, J.-P. et al. 2005. Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro. Journal of biomechanics. 38(5), pp.1143-1154. Katta, J. et al. 2008a. Biotribology of articular cartilage—a review of the recent advances. Medical engineering & physics. 30(10), pp.1349-1363. Katta, J. et al. 2008b. Friction and wear of native and GAG deficient articular cartilage. In: World Biomaterials Congress, p.1191. Keller, T.S. et al. 1996. Relationship between vertical ground reaction force and speed during walking, slow jogging, and running. Clinical biomechanics. 11(5), pp.253-259. Khanna, V. et al. 2014. Cartilage restoration of the hip using fresh osteochondral allograft: resurfacing the potholes. The bone & joint journal. 96(11_Supple_A), pp.11-16. Kim, Y.-H. et al. 2016. Long-term results of third-generation ceramic-on-ceramic bearing cementless total hip arthroplasty in young patients. The Journal of arthroplasty. 31(11), pp.2520-2524. Knight, L. et al. 2005. Influence of cross-shear on the wear of polyethylene: A finite element study. Transactions of the Orthopaedic Research Society. p0987. Kostamo, T. et al. 2009. No difference in gender-specific hip replacement outcomes. Clinical orthopaedics and related research. 467(1), pp.135-140. Kotzar, G. et al. 1995. Torsional loads in the early postoperative period following total hip replacement. Journal of Orthopaedic Research. 13(6), pp.945-955. Kotzar, G. et al. 1991. Telemeterized in vivo hip joint force data: a report on two patients after total hip surgery. Journal of Orthopaedic Research. 9(5), pp.621-633. Kubo, T. et al. 2015. Hip arthroscopic osteochondral autologous transplantation for treating osteochondritis dissecans of the femoral head. Arthroscopy techniques. 4(6), pp.e675-e680. Kuhn, M. et al. 2013. Total hip arthroplasty in patients 50 years or less: do we improve activity profiles? The Journal of arthroplasty. 28(5), pp.872-876. Kuntze, G. et al. 2010. A biomechanical analysis of common lunge tasks in badminton. Journal of sports sciences. 28(2), pp.183-191. Kurtz, S.M. 2009. UHMWPE Biomaterials Handbook. Oxford: Elsevier, Academic Press. Kurtz, S.M. et al. 2009. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clinical Orthopaedics and Related Research®. 467(10), pp.2606-2612. 336 | P a g e Kwon, Y.-M. et al. 2010. Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours. The Journal of bone and joint surgery. British volume. 92(3), pp.356-361. Kwon, Y.-M. et al. 2012. In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours. Bone & joint research. 1(4), pp.42-49. Kyriazis, V. and Rigas, C. 2002. Temporal gait analysis of hip osteoarthritic patients operated with cementless hip replacement. Clinical Biomechanics. 17(4), pp.318-321. Lamontagne, M. et al. 2012. Lower‐limb joint mechanics after total hip arthroplasty during sitting and standing tasks. Journal of Orthopaedic Research. 30(10), pp.1611-1617. Lancaster, J. 1973. Dry bearings: a survey of materials and factors affecting their performance. Tribology. 6(6), pp.219-251. Learmonth, I.D. et al. 2007. The operation of the century: total hip replacement. The Lancet. 370(9597), pp.1508-1519. Lees, A. and Hurley, C. 1995. 29 Forces in a badminton lunge movement. Science and racket sports. p186. Leslie, E. et al. 2001. Age-related differences in physical activity levels of young adults. Medicine and science in sports and exercise. 33(2), pp.255-258. Lewinnek, G.E. et al. 1978. Dislocations after total hip-replacement arthroplasties. The Journal of bone and joint surgery. American volume. 60(2), pp.217-220. Lewis, C.L. and Sahrmann, S.A. 2015. Effect of posture on hip angles and moments during gait. Manual therapy. 20(1), pp.176-182. Li, J. et al. 2015. Unilateral total hip replacement patients with symptomatic leg length inequality have abnormal hip biomechanics during walking. Clinical Biomechanics. 30(5), pp.513-519. Li, J. et al. 2014. Hip contact forces in asymptomatic total hip replacement patients differ from normal healthy individuals: implications for preclinical testing. Clinical Biomechanics. 29(7), pp.747-751. Lipshitz, H. et al. 1980. In vitro studies of the wear of articular cartilage—III. The wear characteristics of chemically modified articular cartilage when worn against a highly polished characterized stainless steel surface. Journal of biomechanics. 13(5), pp.423-436. Lipshitz, H. and Glimcher, M. 1975. In vitro wear of articular cartilage. The Journal of bone and joint surgery. American volume. 57(4), pp.527-534. Lipshitz, H. and Glimcher, M.N.J. 1976. Changes in the hexosamine content and swelling ratio of articular cartilage as functions of depth from the surface. The Journal of bone and joint surgery. American volume. 58(8), pp.1149-1153. Liu, F. et al. 2006. Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 220(6), pp.695-704. Liu, Y. et al. 2017. Recent progress in cartilage tissue engineering—our experience and future directions. Engineering. 3(1), pp.28-35. 337 | P a g e Livermore, J. et al. 1990. Effect of femoral head size on wear of the polyethylene acetabular component. The Journal of bone and joint surgery. American volume. 72(4), pp.518-528. Lombardi Jr, A.V. et al. 2000. An in vivo determination of total hip arthroplasty pistoning during activity. The Journal of Arthroplasty. 15(6), pp.702-709. Lu, X. et al. 2006. The Stribeck curve: experimental results and theoretical prediction. Journal of tribology. 128(4), pp.789-794. Lund et al. 2019. AnyPyTools: A Python package for reproducible research with the AnyBody Modeling System. Journal of Open Source Software. 4(33), p1108. Lunn, D.E. et al. 2019. Hip kinematics and kinetics in total hip replacement patients stratified by age and functional capacity. Journal of Biomechanics. Lunn, D.E. et al. 2016. Basic biomechanics of the hip. Orthopaedics and Trauma. 30(3), pp.239-246. Lynn, S.K. and Noffal, G.J. 2012. Lower extremity biomechanics during a regular and counterbalanced squat. The Journal of Strength & Conditioning Research. 26(9), pp.2417-2425. Macdonald, S.J. et al. 2003. Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clinical Orthopaedics and Related Research®. 406(1), pp.282-296. Mahoney, O.M. 1990. Unsatisfactory results with a ceramic total hip prosthesis. The Journal of bone and joint surgery. American volume. 72(5), pp.663-671. Mak, M. et al. 2002. Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 216(6), pp.403-408. Maldonado, D.R. et al. 2018. Fresh Femoral Head Osteochondral Allograft Transplantation for Treating Osteochondritis Dissecans of the Femoral Head. Arthroscopy techniques. 7(4), pp.e331-e335. Manders, C. et al. 2008. Validation of musculoskeletal gait simulation for use in investigation of total hip replacement. Journal of Biomechanics. 41, pS488. Masonis, J.L. and Bourne, R.B. 2002. Surgical approach, abductor function, and total hip arthroplasty dislocation. Clinical Orthopaedics and Related Research (1976-2007). 405, pp.46-53. Mathieson, A. 2000. NICE issues guidance on hips. The Journal of Perioperative Practice. 10(6), p285. Matthies, A. et al. 2011. Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing. The Journal of bone and joint surgery. British volume. 93(3), pp.307-314. McConnell, T.H. and Hull, K.L. 2011. Human form human function: Essentials of anatomy and physiology. 1st ed. Baltimore, MD: Lippincott Williams & Wilkins. McCrory, J.L. et al. 2001. Vertical ground reaction forces: objective measures of gait following hip arthroplasty. Gait & posture. 14(2), pp.104-109. McGrory, B.J. et al. 1995. Participation in sports after hip and knee arthroplasty: review of literature and survey of surgeon preferences. In: Mayo Clinic Proceedings: Elsevier, pp.342-348. 338 | P a g e McKee, G. 1970. 10 Development of Total Prosthetic Replacement of the Hip. Clinical Orthopaedics and Related Research®. 72, pp.85-103. Meftah, M. et al. 2013. A novel method for accurate and reproducible functional cup positioning in total hip arthroplasty. The Journal of arthroplasty. 28(7), pp.1200-1205. Meira, E.P. and Zeni, J. 2014. Sports participation following total hip arthroplasty. International journal of sports physical therapy. 9(6), p839. Mellon, S. et al. 2011. The effect of motion patterns on edge-loading of metal-on-metal hip resurfacing. Medical engineering & physics. 33(10), pp.1212-1220. Meneghini, R.M. et al. 2006. Muscle damage during MIS total hip arthroplasty: Smith-Peterson versus posterior approach. Clinical Orthopaedics and Related Research®. 453, pp.293-298. Moisio, K.C. et al. 2003. Normalization of joint moments during gait: a comparison of two techniques. Journal of Biomechanics. 36, pp.599-603. Mollon, B. et al. 2013. The clinical status of cartilage tissue regeneration in humans. Osteoarthritis and cartilage. 21(12), pp.1824-1833. Moretti, V.M. and Post, Z.D. 2017. Surgical approaches for total hip arthroplasty. Indian journal of orthopaedics. 51(4), p368. Morlock, M. et al. 2001. Duration and frequency of every day activities in total hip patients. Journal of biomechanics. 34(7), pp.873-881. Mow, V. and Ateshian, G. 1997. In Lubrication and Wear of Diarthrodial Joints: Basic Orthopaedic Biomechanics; Mow, VC; Hayes, WC, Eds. Lippincott-Raven, Philadelphia. Mow, V.C. et al. 1993. Biomechanics of diarthrodial joints: a review of twenty years of progress. Journal of biomechanical engineering. 115(4B), pp.460-467. Mulholland, S.J. and Wyss, U.P. 2001. Activities of daily living in non-Western cultures: range of motion requirements for hip and knee joint implants. International Journal of Rehabilitation Research. 24(3), pp.191-198. Müller, M. et al. 2011. Randomized controlled trial of abductor muscle damage in relation to the surgical approach for primary total hip replacement: minimally invasive anterolateral versus modified direct lateral approach. Archives of orthopaedic and trauma surgery. 131(2), pp.179-189. Murray, M. et al. 1975. Kinesiology after McKee-Farrar total hip replacement. A two-year follow-up of one hundred cases. The Journal of bone and joint surgery. American volume. 57(3), pp.337-342. Murray, M. et al. 1972. Kinesiologic Measurements of Functional Performance Before and After Mckee-farrar Total Hip Replacement: A Study Of Thirty Patients With Rheumatoid Arthritis, Osteoarthritis, Or Avascular Necrosis Of The Femoral Head. JBJS. 54(2), pp.237-256. Nadzadi, M.E. et al. 2003. Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. Journal of biomechanics. 36(4), pp.577-591. Nagura, T. et al. 2002. Mechanical loads at the knee joint during deep flexion. Journal of Orthopaedic Research. 20(4), pp.881-886. 339 | P a g e Nevelos, J. et al. 2001. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. The Journal of bone and joint surgery. British volume. 83(4), pp.598-603. NHS. 2019. Hip replacement. [Online]. Available from: https://www.nhs.uk/conditions/hip-replacement/. NICE. 2002. The clinical effectiveness and cost effectiveness of metal on metal hip resurfacing. [Online]. [Accessed 26 October 2016]. Available from: http://guidance.nice.org.uk/TA44. Nigg, B.M. et al. 1999. Biomechanics of the musculo-skeletal system. Wiley New York. NJR. 2018. National Joint Registry Centre. [Online]. [Accessed 26 October 2016]. Available from: www.njrcentre.org.uk. O'Connor, D.O. et al. 1996. In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair‐climbing. Journal of orthopaedic research. 14(5), pp.769-777. O'Connor, J.D. et al. 2018. Long-term hip loading in unilateral total hip replacement patients is no different between limbs or compared to healthy controls at similar walking speeds. Journal of biomechanics. 80, pp.8-15. Oladeji, L.O. et al. 2018. Large fresh osteochondral allografts for the hip: growing the evidence. HIP International. 28(3), pp.284-290. Oonishi, H. et al. 2004. Alumina hip joints characterized by run‐in wear and steady‐state wear to 14 million cycles in hip‐simulator model. Journal of Biomedical Materials Research Part A: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for Biomaterials. 70(4), pp.523-532. Oonishi, H. et al. 1998. Retrieved total hip prostheses. Part I: the effects of cup thickness, head sizes and fusion defects on wear. Journal of Materials Science: Materials in Medicine. 9(7), pp.393-401. Paul, J. 1966. Paper 8: forces transmitted by joints in the human body. In: Proceedings of the Institution of Mechanical Engineers, Conference Proceedings: SAGE Publications Sage UK: London, England, pp.8-15. Pearsall, D. and Costigan, P. 1999. The effect of segment parameter error on gait analysis results. Gait & Posture. 9(3), pp.173-183. Perron, M. et al. 2003. Assessing advanced locomotor recovery after total hip arthroplasty with the timed stair test. Clinical rehabilitation. 17(7), pp.780-786. Perron, M. et al. 2000. Three-dimensional gait analysis in women with a total hip arthroplasty. Clinical Biomechanics. 15(7), pp.504-515. Peters, A. et al. 2010. Quantification of soft tissue artifact in lower limb human motion analysis: a systematic review. Gait & posture. 31(1), pp.1-8. Pfirrmann, C.W. et al. 2005. Abductor tendons and muscles assessed at MR imaging after total hip arthroplasty in asymptomatic and symptomatic patients. Radiology. 235(3), pp.969-976. Prosser, G.H. et al. 2010. Outcome of primary resurfacing hip replacement: evaluation of risk factors for early revision: 12,093 replacements from the Australian Joint Registry. Acta orthopaedica. 81(1), pp.66-71. 340 | P a g e Queen, R.M. et al. 2013. Stair ascending and descending in hip resurfacing and large head total hip arthroplasty patients. The Journal of arthroplasty. 28(4), pp.684-689. Radin, E.L. and Paul, I.L. 1971. Response of joints to impact loading. I. In vitro wear. Arthritis & Rheumatism: Official Journal of the American College of Rheumatology. 14(3), pp.356-362. Ramamurti, B.S. et al. 1996. Loci of movement of selected points on the femoral head during normal gait: three-dimensional computer simulation. The Journal of arthroplasty. 11(7), pp.845-852. Riberto, M. et al. 2013. Setting up a human motion analysis laboratory: camera positioning for kinematic recording of gait. Int J Phys Med Rehabil. 1(131), p2. Ritter, M.A. and Meding, J.B. 1987. Total hip arthroplasty. Can the patient play sports again? Orthopedics. 10, pp.1447-52. Ritter, M.A. et al. 1983. Correlation of prosthetic femoral head size and/or design with longevity of total hip arthroplasty. Clinical orthopaedics and related research. (176), pp.252-257. Robertson, G. et al. 2013. Research methods in biomechanics, 2E. Human Kinetics. Roebroeck, M. et al. 1994. Biomechanics and muscular activity during sit-to-stand transfer. Clinical Biomechanics. 9(4), pp.235-244. Rydell, N.W. 1966. Forces acting on the femoral head-prosthesis: a study on strain gauge supplied prostheses in living persons. Acta Orthopaedica Scandinavica. 37(sup88), pp.1-132. Saikko, V. 2014. In vitro wear simulation on the RandomPOD wear testing system as a screening method for bearing materials intended for total knee arthroplasty. Journal of biomechanics. 47(11), pp.2774-2778. Saikko, V. and Calonius, O. 2002. Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. Journal of Biomechanics. 35(4), pp.455-464. Saikko, V. et al. 2003. Effect of extent of motion and type of load on the wear of polyethylene in a biaxial hip simulator. Journal of Biomedical Materials Research Part B: Applied Biomaterials: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for Biomaterials. 65(1), pp.186-192. Saikko, V.O. 1996. A three-axis hip joint simulator for wear and friction studies on total hip prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 210(3), pp.175-185. Schache, A.G. et al. 2001. The effect of differing Cardan angle sequences on three dimensional lumbo-pelvic angular kinematics during running. Medical engineering & physics. 23(7), pp.495-503. Scheerlinck, T. 2014. Cup positioning in total hip arthroplasty. Acta Orthop Belg. 80(03), pp.336-347. Schmalzried, T.P. 2012. Patient activity and hip wear. In: Seminars in Arthroplasty: Elsevier, pp.193-196. Schmalzried, T.P. et al. 1996. Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces. The Journal of arthroplasty. 11(3), pp.322-331. 341 | P a g e Schmalzried, T.P. et al. 2000. Wear is a function of use, not time. Clinical Orthopaedics and Related Research (1976-2007). 381, pp.36-46. Schmalzried, T.P. et al. 1998. Quantitative assessment of walking activity after total hip or knee replacement. JBJS. 80(1), pp.54-9. Schmidt, M. et al. 1996. Cobalt chromium molybdenum metal combination for modular hip prostheses. Clinical Orthopaedics and Related Research®. 329, pp.S35-S47. Schoenfeld, B.J. 2010. Squatting kinematics and kinetics and their application to exercise performance. The Journal of Strength & Conditioning Research. 24(12), pp.3497-3506. Scholes, S. and Unsworth, A. 2000. Comparison of friction and lubrication of different hip prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 214(1), pp.49-57. Schreven, S. et al. 2015. Optimising filtering parameters for a 3D motion analysis system. Journal of Electromyography and Kinesiology. 25(5), pp.808-814. Schwachmeyer, V. et al. 2013. In vivo hip joint loading during post-operative physiotherapeutic exercises. PLoS One. 8(10), pe77807. Seagrave, K.G. et al. 2017. Acetabular cup position and risk of dislocation in primary total hip arthroplasty: a systematic review of the literature. Acta orthopaedica. 88(1), pp.10-17. Sechriest II, V.F. et al. 2007. Activity level in young patients with primary total hip arthroplasty: a 5-year minimum follow-up. The Journal of arthroplasty. 22(1), pp.39-47. Sedel, L. et al. 1990. Alumina-on-alumina hip replacement. Results and survivorship in young patients. The Journal of bone and joint surgery. British volume. 72(4), pp.658-663. Selbie, W.S. et al. 2014. Three-dimensional kinetics. Research methods in biomechanics. pp.151-176. Shaju, K. et al. 2005. The 22-mm vs the 32-mm femoral head in cemented primary hip arthroplasty: long-term clinical and radiological follow-up study. The Journal of arthroplasty. 20(7), pp.903-908. Shon, W.Y. et al. 2005. Impingement in total hip arthroplasty: a study of retrieved acetabular components. The Journal of arthroplasty. 20(4), pp.427-435. Sieber, H.-P. et al. 1999. Analysis of 118 second-generation metal-on-metal retrieved hip implants. The Journal of bone and joint surgery. British volume. 81(1), pp.46-50. Silva, M. et al. 2002. Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity. The Journal of arthroplasty. 17(6), pp.693-697. Simon, S.R. 2004. Quantification of human motion: gait analysis—benefits and limitations to its application to clinical problems. Journal of biomechanics. 37(12), pp.1869-1880. Sinclair, J. et al. 2012. Influence of the helical and six available Cardan sequences on 3D ankle joint kinematic parameters. Sports Biomechanics. 11(3), pp.430-437. Skaggs, D.L. et al. 2000. Variability in gait analysis interpretation. Journal of Pediatric Orthopaedics. 20(6), pp.759-764. 342 | P a g e Smith, A.J. et al. 2012. Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales. The Lancet. 379(9822), pp.1199-1204. Smith, S. et al. 2001. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 215(2), pp.161-170. Smith, S. and Unsworth, A. 2000. Simplified motion and loading compared to physiological motion and loading in a hip joint simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 214(3), pp.233-238. Smith, S. and Unsworth, A. 2001. A five-station hip joint simulator. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 215(1), pp.61-64. Stagni, R. et al. 2000. Effects of hip joint centre mislocation on gait analysis results. Journal of biomechanics. 33(11), pp.1479-1487. Stansfield, B. et al. 2003. Direct comparison of calculated hip joint contact forces with those measured using instrumented implants. An evaluation of a three-dimensional mathematical model of the lower limb. Journal of biomechanics. 36(7), pp.929-936. Stewart, T. 2010. Tribology of artificial joints. Orthopaedics and Trauma. 24(6), pp.435-440. Stewart, T. et al. 1997. Friction of composite cushion bearings for total knee joint replacements under adverse lubrication conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 211(6), pp.451-465. Stolk, J. et al. 2002. Stair climbing is more detrimental to the cement in hip replacement than walking. Clinical Orthopaedics and Related Research®. 405, pp.294-305. Sum, J. et al. 1998. Effects of normalization on joint moments during level walking. Gait & Posture. 7, p184. Swanson, E.A. et al. 2009. Activity recommendations after total hip and knee arthroplasty: a survey of the American Association for Hip and Knee Surgeons. The Journal of arthroplasty. 24(6), pp.120-126. Sychterz, C.J. et al. 1999. Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in. JBJS. 81(6), pp.821-830. Talis, V. et al. 2008. Asymmetric leg loading during sit-to-stand, walking and quiet standing in patients after unilateral total hip replacement surgery. Clinical Biomechanics. 23(4), pp.424-433. Temple, J. 2004. Total hip replacement. Nursing Standard (through 2013). 19(3), p44. Thier, S. et al. 2017. Arthroscopic autologous chondrocyte implantation in the hip for the treatment of full-thickness cartilage defects: A case series of 29 patients and review of the literature. SICOT-J. 3. 343 | P a g e Tirico, L.E. et al. 2018. Modern Osteochondral Allograft Transplantation: The “Gold Standard” for Femoral Condyle Cartilage Repair? Orthopaedic journal of sports medicine. 6(3_suppl), p2325967118S00004. Turell, M. et al. 2003. Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene. Wear. 255(7-12), pp.1034-1039. Underwood, R.J. et al. 2012. Edge loading in metal-on-metal hips: low clearance is a new risk factor. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 226(3), pp.217-226. van Arkel, R.J. et al. 2013. Hip abduction can prevent posterior edge loading of hip replacements. Journal of Orthopaedic Research. 31(8), pp.1172-1179. Van der Weegen, W. et al. 2011. Survival of metal-on-metal hip resurfacing arthroplasty: a systematic review of the literature. The Journal of bone and joint surgery. British volume. 93(3), pp.298-306. VanLaanen, J.B. 2013. Validation of a cross-shear model for ultra-high molecular weight polyethylene (UHMWPE) wear. Master of Science thesis, Colorado School of Mines. Vassiliou, K. et al. 2007. Laboratory studies on the tribology of hard bearing hip prostheses: ceramic on ceramic and metal on metal. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 221(1), pp.11-20. Vaughan-Graham, J. et al. 2019. Transitions sit to stand and stand to sit in persons post-stroke: Path of centre of mass, pelvic and limb loading–A pilot study. Clinical Biomechanics. 61, pp.22-30. Visuri, T. and Honkanen, R. 1978. The influence of total hip replacement on selected activities of daily living and on the use of domestic aid. Scandinavian journal of rehabilitation medicine. 10(4), pp.221-225. Visuri, T. and Honkanen, R. 1980. Total hip replacement: its influence on spontaneous recreation exercise habits. Arch Phys Med Rehabil. 61(7), pp.325-8. Walter, W.L. et al. 2004. Edge loading in third generation alumina ceramic-on-ceramic bearings: Stripe wear1. The Journal of arthroplasty. 19(4), pp.402-413. Wang, A. 2001. A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding. Wear. 248(1-2), pp.38-47. Wang, A. et al. 1998. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribology International. 31(1-3), pp.17-33. Wang, A. et al. 1997b. The significance of nonlinear motion in the wear screening of orthopaedic implant materials. Journal of Testing and Evaluation. 25(2), pp.239-245. Wang, A. et al. 1996. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 210(3), pp.141-155. Wang, A. et al. 1997a. Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene. Wear. 203, pp.230-241. Wang, Y. et al. 2006. Development of a set of stribeck curves for conformal contacts of rough surfaces. Tribology Transactions. 49(4), pp.526-535. 344 | P a g e Wannop, J.W. et al. 2012. Normalization of ground reaction forces, joint moments, and free moments in human locomotion. Journal of Applied Biomechanics. 28(6), pp.665-76. Wehner, T. et al. 2009. Internal loads in the human tibia during gait. Clinical Biomechanics. 24(3), pp.299-302. Widhalm, R. et al. 1990. Is there greater danger of sports injury or osteoporosis caused by inactivity in patients with hip prosthesis? Sequelae for long-term stability of prosthesis anchorage. Zeitschrift fur Orthopadie und ihre Grenzgebiete. 128(2), pp.139-143. Winter, D.A. 1984. Kinematic and kinetic patterns in human gait: variability and compensating effects. Human movement science. 3(1-2), pp.51-76. Winter, D.A. 2009. Biomechanics and motor control of human movement. John Wiley & Sons. Wylde, V. et al. 2008. Return to sport after joint replacement. The Journal of bone and joint surgery. British volume. 90(7), pp.920-923. Yoshida, H. et al. 2006. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living. Journal of biomechanics. 39(11), pp.1996-2004. Yu, B. et al. 1999. Estimate of the optimum cutoff frequency for the Butterworth low-pass digital filter. Journal of Applied Biomechanics. 15(3), pp.318-329. Yusuf, H.R. et al. 1996. Leisure-time physical activity among older adults: United States, 1990. Archives of internal medicine. 156(12), pp.1321-1326. Zhou, Y. et al. 1997. Start up and steady state friction of alumina against alumina. Wear. 210(1-2), pp.112-119. Zywiel, M.G. et al. 2011. State of the art in hard-on-hard bearings: how did we get here and what have we achieved? Expert review of medical devices. 8(2), pp.187-207."],"dcterms:accessrights":["public"],"dc:title":["Understanding Movement and its Influence on Tribology of the Human Hip"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T22:38:08Z"}