{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:28397"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:28397","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Is pacemaker-induced cardiac dysfunction progressive and reversible in patients receiving long-term pacemaker therapy?","abstract":null,"abstract_html":null,"abstract_has_math":false,"creators":["Paton, Maria Frances"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Witte, Klaus","Cairns, David"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-08","date_published":"2020-08","updated_at":"2026-11-18T22:41:20Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.826711"],"render_values":[{"text":"uk.bl.ethos.826711","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["2016-02-055"],"render_values":[{"text":"2016-02-055","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000185174621"],"render_values":[{"text":"0000-0001-8517-4621","href":"https://orcid.org/0000-0001-8517-4621","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/28397/1/PDFVersion1.2_MariaPaton_Thesis02.11.2020.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A28397","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Witte, Klaus","Cairns, David"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["NIHR"]},{"key":"dc:creator","label":"Author","values":["Paton, Maria Frances"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000185174621"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-08"]},{"key":"dc:date.issued","label":"Date","values":["2020-08"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Faculty of Medicine and Health (Leeds)","School of Medicine (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/28397/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["ABDULLA, J., BARLERA, S., LATINI, R., KJOLLER‐HANSEN, L., SOGAARD, P., CHRISTENSEN, E., KOBER, L. & TORP‐PEDERSEN, C. 2007. A systematic review: effect of angiotensin converting enzyme inhibition on left ventricular volumes and ejection fraction in patients with a myocardial infarction and in patients with left ventricular dysfunction. European journal of heart failure, 9, 129-135. ADOMIAN, G. E. & BEAZELL, J. 1986. Myofibrillar disarray produced in normal hearts by chronic electrical pacing. American heart journal, 112, 79-83. AHMED, F. Z., MOTWANI, M., CUNNINGTON, C., KWOK, C. S., FULLWOOD, C., OCEANDY, D., FITCHET, A., GOODE, G. K., LUCKIE, M. & ZAIDI, A. M. 2017. One-month global longitudinal strain identifies patients who will develop pacing-induced left ventricular dysfunction over time: the pacing and ventricular dysfunction (PAVD) study. PloS one, 12, e0162072. ANDERSEN, G., GREEN, A., MADSEN, G. M. & ARNSBO, P. 1991. The epidemiology of pacemaker implantations in Fyn county, Denmark. Pacing and Clinical Electrophysiology, 14, 1614-1621. ANDERSEN, H. R., NIELSEN, J. C., THOMSEN, P. E. B., THUESEN, L., MORTENSEN, P. T., VESTERLUND, T. & PEDERSEN, A. K. 1997. Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome. The Lancet, 350, 1210-1216. ARKOLAKI, E. G., SIMANTIRAKIS, E. N., KONTARAKI, J. E., CHRYSOSTOMAKIS, S. I., PATRIANAKOS, A. P., CHLOUVERAKIS, G. I., NAKOU, E. S. & VARDAS, P. E. 2015. Alterations in the expression of genes related to contractile function and hypertrophy of the left ventricle in chronically paced patients from the right ventricular apex. Ep Europace, 17, 1563-1570. ARMSTRONG, P. W., STOPPS, T. P., FORD, S. E. & DE BOLD, A. J. 1986. Rapid ventricular pacing in the dog: pathophysiologic studies of heart failure. Circulation, 74, 1075-1084. ARONOW, W. S. & GREGORATOS, G. 1999. MANAGEMENT OF ATRIAL FIBRILLATION, VENTRICULAR ARRHYTHMIAS AND PACEMAKERS IN OLDER PERSONS: Permanent Pacemakers in Older Persons. Journal of the American Geriatrics Society, 47, 1125-1135. ARTIS, N., OXBOROUGH, D., WILLIAMS, G., PEPPER, C. & TAN, L. 2008. Two-dimensional strain imaging: a new echocardiographic advance with research and clinical applications. International journal of cardiology, 123, 240-248. AUGER, D., HOKE, U., MARSAN, N. A., TOPS, L. F., LEONG, D. P., BERTINI, M., SCHALIJ, M. J., BAX, J. J. & DELGADO, V. 2014. Effect of Induced LV Dyssynchrony by Right Ventricular Apical Pacing on All‐Cause Mortality and Heart Failure Hospitalization Rates at Long‐Term Follow‐Up. Journal of cardiovascular electrophysiology, 25, 631-637. BAROLD, S. S. 1996. Indications for permanent cardiac pacing in first‐degree AV block: class I, II, or III? Pacing and clinical electrophysiology, 19, 747-751. BAROLD, S. S. & HERWEG, B. 2012. Conventional and biventricular pacing in patients with first-degree atrioventricular block. Europace, 14, 1414-1419. BAROLD, S. S. & LEVINE, P. A. 2001. Pacemaker repetitive nonreentrant ventriculoatrial synchronous rhythm. A review. Journal of interventional cardiac electrophysiology, 5, 59-66. BAROLD, S. S. & WINNER, J. A. 1976. Techniques and Significance of Threshold Measurement for Cardiac Pacing: Relationship to Output Circuit of Cardiac Pacemakers. Chest, 70, 760-766. BATEY, R. L., SWEESY, M. W., SCALA, G. & FORNEY, R. C. 1990. Comparison of low rate dual chamber pacing to activity responsive rate variable ventricular pacing. Pacing and Clinical Electrophysiology, 13, 646-652. BEDOTTO, J. B., GRAYBURN, P. A., BLACK, W. H., RAYA, T. E., MCBRIDE, W., HSIA, H. H. & EICHHORN, E. J. 1990. Alterations in left ventricular relaxation during atrioventricular pacing in humans. Journal of the American College of Cardiology, 15, 658-664. BENKEMOUN, H., SACREZ, J., LAGRANGE, P., AMIEL, A., PRAKASH, A., HIMMRICH, E., AIME, E., MAIRESSE, G. H., GUENON, C. & SBRAGIA, P. 2012a. Optimizing pacemaker longevity with pacing mode and settings programming: results from a pacemaker multicenter registry. Pacing and clinical electrophysiology, 35, 403-408. BENKEMOUN, H., SACREZ, J., LAGRANGE, P., AMIEL, A., PRAKASH, A., HIMMRICH, E., AIMÈ, E., MAIRESSE, G. H., GUÉNON, C. & SBRAGIA, P. 2012b. Optimizing Pacemaker Longevity with Pacing Mode and Settings Programming: Results from a Pacemaker Multicenter Registry. Pacing and Clinical Electrophysiology, 35, 403-408. BERGER, T., ROITHINGER, F. X., ANTRETTER, H., HANGLER, H., PACHINGER, O. & HINTRINGER, F. 2003. The influence of high versus normal impedance ventricular leads on pacemaker generator longevity. Pacing Clin Electrophysiol, 26, 2116-20. BERNSTEIN, A. D., IRWIN, M. E., PARSONNET, V., WILKOFF, B. L., BLACK, W. R., BUCKINGHAM, T. A., MALONEY, J. D., REYNOLDS, D. D., SAKSENA, S. & SINGER, I. 1994. Report of the NASPE Policy Conference on Antibradycardia Pacemaker Follow‐Up: Effectiveness, Needs, and Resources. Pacing and Clinical Electrophysiology, 17, 1714-1729. BETOCCHI, S., PISCIONE, F., VILLARI, B., PACE, L., CIARMIELLO, A., PERRONE-FILARDI, P., SALVATORE, C., SALVATORE, M. & CHIARIELLO, M. 1993. Effects of induced asynchrony on left ventricular diastolic function in patients with coronary artery disease. Journal of the American College of Cardiology, 21, 1124-1131. BHRS 2015. British Heart Rhythm Society Clinical Guidance for the Follow-up of Cardiac Implantable Electronic Devices for Cardiac Rhythm Management. BHRS 2020. Clinical Standards And Guidelines For The Follow-up of Cardiac Implantable Electronic Devices (CIEDs) for Cardiac Rhythm Management BHRS Clinical Standards. Avalable Online. BLANC, J. & INVESTIGATORS, B. T. Biventricular pacing for atrio-ventricular block to prevent cardiac desynchronization. Results presented at European Society of Cardiology Congress, Barcelona, Spain, 2014. BORIANI, G., RUSCONI, L., BIFFI, M., PAVIA, L., SASSARA, M., MALFITANO, D., BONGIORNI, M. G., PADELETTI, L., FILICE, I. & SANFELICI, D. 2006. Role of ventricular autocapture function in increasing longevity of DDDR pacemakers: a prospective study. Europace, 8, 216-220. BOSSUYT, P. M., REITSMA, J. B., BRUNS, D. E., GATSONIS, C. A., GLASZIOU, P. P., IRWIG, L., LIJMER, J. G., MOHER, D., RENNIE, D., DE VET, H. C., KRESSEL, H. Y., RIFAI, N., GOLUB, R. M., ALTMAN, D. G., HOOFT, L., KOREVAAR, D. A., COHEN, J. F. & GROUP, S. 2015. STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies. Clin Chem, 61, 1446-52. BRADSHAW, P. J., STOBIE, P., KNUIMAN, M. W., BRIFFA, T. G. & HOBBS, M. S. 2014a. Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population. Open heart, 1, e000177. BRADSHAW, P. J., STOBIE, P., KNUIMAN, M. W., BRIFFA, T. G. & HOBBS, M. S. T. 2014b. Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population. Open Heart, 1, e000177. BRECKER, S. J., XIAO, H., SPARROW, J. & GIBSON, D. 1992. Effects of dual-chamber pacing with short atrioventricular delay in dilated cardiomyopathy. The Lancet, 340, 1308-1312. BREIVIK, K., OHM, O. J. & SEGADAL, L. 1979. Sick sinus syndrome treated with permanent pacemaker in 109 patients: a follow‐up study. Acta medica Scandinavica, 206, 153-159. BRIGNOLE, M., AURICCHIO, A., BARON-ESQUIVIAS, G., BORDACHAR, P., BORIANI, G., BREITHARDT, O., CLELAND, J., DEHARO, J., DELGADO, V. & ELLIOTT, P. 2013a. Document Reviewers. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J, 34, 2281-2329. BRIGNOLE, M., AURICCHIO, A., BARON-ESQUIVIAS, G., BORDACHAR, P., BORIANI, G., BREITHARDT, O.-A., CLELAND, J., DEHARO, J.-C. & DELGADO, V. 2013b. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). European heart journal, 34, 2281-2329. BRUNNER, M., OLSCHEWSKI, M., GEIBEL, A., BODE, C. & ZEHENDER, M. 2004. Long-term survival after pacemaker implantation: Prognostic importance of gender and baseline patient characteristics. European Heart Journal, 25, 88-95. BURRI, H., SUNTHORN, H., DORSAZ, P. A. & SHAH, D. 2005. Prospective study of axillary vein puncture with or without contrast venography for pacemaker and defibrillator lead implantation. Pacing and clinical electrophysiology, 28, S280-S283. CAPUCCI, A., BORIANI, G., SPECCHIA, S., MARINELLI, M., SANTARELLI, A. & MAGNANI, B. 1992. Evaluation by cardiopulmonary exercise test of DDDR versus DDD pacing. Pacing and Clinical Electrophysiology, 15, 1908-1913. CARLSON, M. D., IP, J., MESSENGER, J., BEAU, S., KALBFLEISCH, S., GERVAIS, P., CAMERON, D. A., DURAN, A., VAL-MEJIAS, J. & MACKALL, J. 2003. A new pacemaker algorithm for the treatment of atrial fibrillation: results of the Atrial Dynamic Overdrive Pacing Trial (ADOPT). Journal of the American College of Cardiology, 42, 627-633. CARMOUCHE, D. G., BUBIEN, R. S. & KAY, G. N. 1998. The effect of maximum heart rate on oxygen kinetics and exercise performance at low and high workloads. Pacing and clinical electrophysiology, 21, 679-686. CARROZ, P., DELAY, D. & GIROD, G. 2010. Pseudo-pacemaker syndrome in a young woman with first-degree atrio-ventricular block. Europace, 12, 594-596. CASTELNUOVO, E., STEIN, K., PITT, M., GARSIDE, R. & PAYNE, E. 2005. The effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber pacemakers for bradycardia due to atrioventricular block or sick sinus syndrome: systematic review and economic evaluation. NIHR Health Technology Assessment programme: Executive Summaries. NIHR Journals Library. CHATTERJEE, S., BIONDI-ZOCCAI, G., ABBATE, A., D’ASCENZO, F., CASTAGNO, D., VAN TASSELL, B., MUKHERJEE, D. & LICHSTEIN, E. 2013. Benefits of β blockers in patients with heart failure and reduced ejection fraction: network meta-analysis. Bmj, 346, f55. CHENG, A., CALKINS, H. & BERGER, R. D. 2009a. Managed ventricular pacing below the lower rate limit: is it simply caused by ventricular-based pacing? Heart rhythm, 6, 1240-1241. CHENG, S., KEYES, M. J., LARSON, M. G., MCCABE, E. L., NEWTON-CHEH, C., LEVY, D., BENJAMIN, E. J., VASAN, R. S. & WANG, T. J. 2009b. Long-term outcomes in individuals with prolonged PR interval or first-degree atrioventricular block. Jama, 301, 2571-2577. CHOW, G. V., MARINE, J. E. & FLEG, J. L. 2012. Epidemiology of arrhythmias and conduction disorders in older adults. Clinics in geriatric medicine, 28, 539-553. COLLINS, G. S., REITSMA, J. B., ALTMAN, D. G. & MOONS, K. G. 2015. Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD): the TRIPOD Statement. Br J Surg, 102, 148-58. CONNOLLY, S. J., KERR, C. R., GENT, M., ROBERTS, R. S., YUSUF, S., GILLIS, A. M., SAMI, M. H., TALAJIC, M., TANG, A. S. & KLEIN, G. J. 2000. Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. New England Journal of Medicine, 342, 1385-1391. CROSSLEY, G. H., GAYLE, D. D., SIMMONS, T. W., HAISTY, W. K., BAILEY, J. R., DAVIS-O'BRIEN, K., HAMMON, J. W. & FITZGERALD, D. M. 1996. Reprogramming pacemakers enhances longevity and is cost-effective. Circulation, 94, II245-7. CUBBON, R. M., GALE, C. P., KEARNEY, L. C., SCHECHTER, C. B., BROOKSBY, W. P., NOLAN, J., FOX, K. A., RAJWANI, A., BAIG, W. & GROVES, D. 2011. Changing characteristics and mode of death associated with chronic heart failure caused by left ventricular systolic dysfunction: a study across therapeutic eras. Circulation: Heart Failure, 4, 396-403. CURTIS, A. B., ADAMSON, P. B., CHUNG, E., JOHN SUTTON, M. S., TANG, F. & WORLEY, S. 2007. Biventricular versus right ventricular pacing in patients with AV block (BLOCK HF): clinical study design and rationale. Journal of cardiovascular electrophysiology, 18, 965-971. CURTIS, A. B., WORLEY, S. J., ADAMSON, P. B., CHUNG, E. S., NIAZI, I., SHERFESEE, L., SHINN, T. & ST JOHN SUTTON, M. 2013. Biventricular pacing for atrioventricular block and systolic dysfunction. N Engl J Med, 368, 1585-1593. CVIJIC, M., DUCHENNE, J., ÜNLÜ, S., MICHALSKI, B., AARONES, M., WINTER, S., AAKHUS, S., FEHSKE, W., STANKOVIC, I. & VOIGT, J.-U. 2017. Timing of myocardial shortening determines left ventricular regional myocardial work and regional remodelling in hearts with conduction delays. European Heart Journal-Cardiovascular Imaging, 19, 941-949. DA COSTA, A., GABRIEL, L., ROMEYER-BOUCHARD, C., GÉRALDINE, B., GATE-MARTINET, A., LAURENCE, B., LEVALLOIS, M. & ISAAZ, K. 2013. Focus on right ventricular outflow tract septal pacing. Archives of cardiovascular diseases, 106, 394-403. DALEN, H., THORSTENSEN, A., AASE, S. A., INGUL, C. B., TORP, H., VATTEN, L. J. & STOYLEN, A. 2009. Segmental and global longitudinal strain and strain rate based on echocardiography of 1266 healthy individuals: the HUNT study in Norway. European Journal of Echocardiography, 11, 176-183. DAVY, J., HOFFMANN, E., FREY, A., JOCHAM, K., ROSSI, S., DUPUIS, J., FRABETTI, L., DUCLOUX, P., PRADES, E. & JAUVERT, G. 2012. Near elimination of ventricular pacing in SafeR mode compared to DDD modes: a randomized study of 422 patients. Pacing and clinical electrophysiology, 35, 392-402. DE VRIES, L., LEENING, M., DIJK, W., HOOIJSCHUUR, C., STRICKER, B. & VAN HEMEL, N. 2017. Trends in service time of pacemakers in the Netherlands: a long-term nationwide follow-up study. Netherlands Heart Journal, 25, 581-591. DEAN, J. & SULKE, N. 2016. Pacemaker battery scandal. British Medical Journal Publishing Group. DEHARO, J. & DJIANE, P. Pacemaker longevity. Replacement of the device. Annales de cardiologie et d'angéiologie, 2005. 26-31. DONOSO, E., ADLER, L. N. & FRIEDBERG, C. K. 1964. Unusual forms of second-degree atrioventricular block, including mobitz type-II block, associated with the Morgagni-Adams-Stokes Syndrome. American heart journal, 67, 150-157. DOROSZ, J. L., LEZOTTE, D. C., WEITZENKAMP, D. A., ALLEN, L. A. & SALCEDO, E. E. 2012. Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis. Journal of the American College of Cardiology, 59, 1799-1808. DUCHENNE, J., TURCO, A., ÜNLÜ, S., PAGOURELIAS, E. D., VUNCKX, K., DEGTIAROVA, G., BÉZY, S., CVIJIC, M., NUYTS, J. & CLAUS, P. 2019. Left ventricular remodeling results in homogenization of myocardial work distribution. Circulation: Arrhythmia and Electrophysiology, 12, e007224. EDHAG, O. 1969. Long-term cardiac pacing. Experience of fixed-rate pacing with an endocardial electrode in 260 patients. Acta medica Scandinavica. Supplementum, 502, 9. ELDRIDGE, S. M., CHAN, C. L., CAMPBELL, M. J., BOND, C. M., HOPEWELL, S., THABANE, L. & LANCASTER, G. A. 2016. CONSORT 2010 statement: extension to randomised pilot and feasibility trials. Pilot and feasibility studies, 2, 64. ELLENBOGEN, K. A., WILKOFF, B. L., KAY, G. N., LAU, C. P. & AURICCHIO, A. 2016. Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy E-Book, Elsevier Health Sciences. EPSTEIN, A. E., DIMARCO, J. P., ELLENBOGEN, K. A., ESTES, N. A., 3RD, FREEDMAN, R. A., GETTES, L. S., GILLINOV, A. M., GREGORATOS, G., HAMMILL, S. C., HAYES, D. L., HLATKY, M. A., NEWBY, L. K., PAGE, R. L., SCHOENFELD, M. H., SILKA, M. J., STEVENSON, L. W., SWEENEY, M. O., AMERICAN COLLEGE OF CARDIOLOGY, F., AMERICAN HEART ASSOCIATION TASK FORCE ON PRACTICE, G. & HEART RHYTHM, S. 2013. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. Circulation, 127, e283-352. ESCHALIER, R., PLOUX, S., RITTER, P., HAÏSSAGUERRE, M., ELLENBOGEN, K. A. & BORDACHAR, P. 2015. Nonspecific intraventricular conduction delay: definitions, prognosis, and implications for cardiac resynchronization therapy. Heart Rhythm, 12, 1071-1079. FELD, G. K. 2014. AV Delay Optimization vs. Intrinsic Conduction in Pacemaker Patients With Long PR Intervals (AV Delay). ClinialTrials.gov. FERGUSON JR, T. B., FERGUSON, C. L., CRITES, K. & CRIMMINS-REDA, P. 1996. The additional hospital costs generated in the management of complications of pacemaker and defibrillator implantations. The Journal of thoracic and cardiovascular surgery, 111, 742-752. FOLEY, P. W., LEYVA, F. & FRENNEAUX, M. P. 2009. What is treatment success in cardiac resynchronization therapy? Europace, 11, v58-v65. FRASER, J. D., GILLIS, A. M., IRWIN, M. E., NISHIMURA, S., TYERS, G. & PHILIPPON, F. 2000. Guidelines for pacemaker follow-up in Canada: a consensus statement of the Canadian Working Group on Cardiac Pacing. The Canadian journal of cardiology, 16, 355-63, 367-76. FREUDENBERGER, R., AARON, M., KRUEGER, S., LABEAU, M., KLECKNER, K. & KLEPFER, R. N. 2008. Acute electromechanical effects of atrioventricular coupled pacing in patients with heart failure. Journal of cardiac failure, 14, 35-40. FRIEDBERG, C. K., DONOSO, E. & STEIN, W. 1964. Nonsurgical acquired heart block. Annals of the New York Academy of Sciences, 111, 835-847. GADLER, F., VALZANIA, C. & LINDE, C. 2014. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry. Ep Europace, 17, 69-77. GARIN, O., HERDMAN, M., VILAGUT, G., FERRER, M., RIBERA, A., RAJMIL, L., VALDERAS, J. M., GUILLEMIN, F., REVICKI, D. & ALONSO, J. 2014. Assessing health-related quality of life in patients with heart failure: a systematic, standardized comparison of available measures. Heart failure reviews, 19, 359-367. GERLAND, P., RAFTERY, A. E., ŠEVČÍKOVÁ, H., LI, N., GU, D., SPOORENBERG, T., ALKEMA, L., FOSDICK, B. K., CHUNN, J. & LALIC, N. 2014. World population stabilization unlikely this century. Science, 346, 234-237. GIERULA, J., CUBBON, R. M., JAMIL, H. A., BYROM, R., BAXTER, P. D., PAVITT, S., GILTHORPE, M. S., HEWISON, J., KEARNEY, M. T. & WITTE, K. K. 2013. Cardiac resynchronization therapy in pacemaker-dependent patients with left ventricular dysfunction. Europace, 15, 1609-1614. GIERULA, J., CUBBON, R. M., JAMIL, H. A., BYROM, R. J., WALDRON, Z. L., PAVITT, S., KEARNEY, M. T. & WITTE, K. K. 2015. Patients with long-term permanent pacemakers have a high prevalence of left ventricular dysfunction. Journal of Cardiovascular Medicine, 16, 743-750. GIERULA, J., JAMIL, H. A., BYROM, R., JOY, E. R., CUBBON, R. M., KEARNEY, M. T. & WITTE, K. K. 2014. Pacing-associated left ventricular dysfunction? Think reprogramming first! Heart, 100, 765-769. GILLIS, A. M. 2006. Redefining physiologic pacing: lessons learned from recent clinical trials. Heart Rhythm, 3, 1367-72. GILLIS, A. M., PÜRERFELLNER, H., ISRAEL, C. W., SUNTHORN, H., KACET, S., ANELLI‐MONTI, M., TANG, F., YOUNG, M., BORIANI, G. & INVESTIGATORS, M. E. C. S. 2006. Reducing unnecessary right ventricular pacing with the managed ventricular pacing mode in patients with sinus node disease and AV block. Pacing and clinical electrophysiology, 29, 697-705. GLICK, H., COOK, J., KINOSIAN, B., PITT, B., BOURASSA, M. G., POULEUR, H. & GERTH, W. 1995. Costs and effects of enalapril therapy in patients with symptomatic heart failure: an economic analysis of the Studies of Left Ventricular Dysfunction (SOLVD) Treatment Trial. Journal of cardiac failure, 1, 371-380. GOLDBERGER, J. J., JOHNSON, N. P. & GIDEA, C. 2011. Significance of asymptomatic bradycardia for subsequent pacemaker implantation and mortality in patients> 60 years of age. The American journal of cardiology, 108, 857-861. GOLDSTEIN, D. J., LOSQUADRO, W. & SPOTNITZ, H. M. 1998. Outpatient pacemaker procedures in orally anticoagulated patients. Pacing and clinical electrophysiology, 21, 1730-1734. H., B. 2014. Pacemakers longevity: Do we get what it is promised? . Journal of Interventional Cardiac Electrophysiology 1. HAGHJOO, M. 2017. Cardiac implantable electronic devices, Elsevier Health Sciences. HALL, N. 2015. Ohms Law [Online]. National Aeronautics and Space Administration. Available: https://www.grc.nasa.gov/www/k-12/airplane/ohms.html [Accessed 01/03/2020 2020]. HALPERIN, J. L., LEVINE, G. N., AL-KHATIB, S. M., BIRTCHER, K. K., BOZKURT, B., BRINDIS, R. G., CIGARROA, J. E., CURTIS, L. H., FLEISHER, L. A. & GENTILE, F. 2016. Further evolution of the ACC/AHA clinical practice guideline recommendation classification system: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation, 133, 1426-1428. HARKNESS, A., RING, L., AUGUSTINE, D. X., OXBOROUGH, D., ROBINSON, S. & SHARMA, V. 2020. Normal reference intervals for cardiac dimensions and function for use in echocardiographic practice: a guideline from the British Society of Echocardiography. Echo research and practice, 7, G1-G18. HAUSER, R. G., KALLINEN, L. M., ALMQUIST, A. K., GORNICK, C. C. & KATSIYIANNIS, W. T. 2007. Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead. Heart Rhythm, 4, 892-896. HAYES, D. L., NACCARELLI, G. V., FURMAN, S., PARSONNET, V., REYNOLDS, D., GOLDSCHLAGER, N., GILLETTE, P., MALONEY, J. D., SAXON, L. & LEON, A. 2003. NASPE training requirements for cardiac implantable electronic devices: selection, implantation, and follow‐up. Pacing and clinical electrophysiology, 26, 1556-1562. HAYES, J. J., SHARMA, A. D., LOVE, J. C., HERRE, J. M., LEONEN, A. O., KUDENCHUK, P. J. & INVESTIGATORS, D. 2006. Abnormal conduction increases risk of adverse outcomes from right ventricular pacing. Journal of the American College of Cardiology, 48, 1628-1633. HAYWOOD, G. A., JONES, S. M., CAMM, A. J. & WARD, D. E. 1991. Day case permanent pacing. Pacing and Clinical Electrophysiology, 14, 773-777. HAYWOOD, G. A., KATRITSIS, D., WARD, J., LEIGH-JONES, M., WARD, D. E. & CAMM, A. J. 1993. Atrial adaptive rate pacing in sick sinus syndrome: effects on exercise capacity and arrhythmias. Heart, 69, 174-178. HEALEY, J., TOFF, W., LAMAS, G. & A, A. H., THORPE KE, ELLENBOGEN K A, ET AL. 2006. Cardiovascular outcomes with atrial-based pacing compared with ventricular pacing: meta-analysis of randomized trials, using individual patient data. Circulation [Internet], 114, 11-7. HEIDBÜCHEL, H., LIOEN, P., FOULON, S., HUYBRECHTS, W., ECTOR, J., WILLEMS, R. & ECTOR, H. 2008. Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator. Europace, 10, 351-357. HEIMDAL, A., STØYLEN, A., TORP, H. & SKJÆRPE, T. 1998. Real-time strain rate imaging of the left ventricle by ultrasound. Journal of the American Society of Echocardiography, 11, 1013-1019. HEYNDRICKX, G., VILAINE, J.-P., KNIGHT, D. & VATNER, S. 1985a. Effects of altered site of electrical activation on myocardial performance during inotropic stimulation. Circulation, 71, 1010-1016. HEYNDRICKX, G. R., VILAINE, J., KNIGHT, D. & VATNER, S. F. 1985b. Effects of altered site of electrical activation on myocardial performance during inotropic stimulation. Circulation, 71, 1010-1016. HOGG, K., SWEDBERG, K. & MCMURRAY, J. 2004. Heart failure with preserved left ventricular systolic function: epidemiology, clinical characteristics, and prognosis. Journal of the American College of Cardiology, 43, 317-327. HOLMQVIST, F., HELLKAMP, A. S., LEE, K. L., LAMAS, G. A. & DAUBERT, J. P. 2014. Adverse Effects of First‐Degree AV‐Block in Patients with Sinus Node Dysfunction: Data from the Mode Selection Trial. Pacing and Clinical Electrophysiology, 37, 1111-1119. HONG, W.-J., YUNG, T.-C., LUN, K.-S., WONG, S. J. & CHEUNG, Y.-F. 2009. Impact of right ventricular pacing on three-dimensional global left ventricular dyssynchrony in children and young adults with congenital and acquired heart block associated with congenital heart disease. American Journal of Cardiology, 104, 700-706. HUSSAIN, M. A., FURUYA‐KANAMORI, L., KAYE, G., CLARK, J. & DOI, S. A. 2015. The effect of right ventricular apical and nonapical pacing on the short‐and long‐term changes in left ventricular ejection fraction: A systematic review and meta‐analysis of randomized‐controlled trials. Pacing and Clinical Electrophysiology, 38, 1121-1136. IGLESIAS, J., BENEZET MAZUECOS, J., CORTES, M., RUBIO, J., DE LA CRUZ, E., DE LA VIEJA, J., CALLE, S., QUINONES, M., SANCHEZ-BORQUE, P. & FARRE, J. Abnormalities in AutoCapture pacemaker algorithm in atrial fibrillation patients compromise battery longevity. EUROPEAN HEART JOURNAL, 2014. OXFORD UNIV PRESS GREAT CLARENDON ST, OXFORD OX2 6DP, ENGLAND, 103-104. IORGULESCU, C., RADU, D., CONSTANTINESCU, D., CALDARARU, C. & DOROBANTU, M. 2014. Right ventricular septal pacing-clinical and electrical predictors for LV contraction asynchrony. Journal of medicine and life, 7, 83-89. IRNICH, W. 1975. Engineering concepts of pacemaker electrodes. Engineering in Medicine. Springer. J MORENO PLANAS, M. S., S BOVEDA, P MABO, F BODE, J RODRIGUEZ GARCIA, G CARRERAS, D BUKART-KUTTNER, A ROUSSEAU-PLASSE ), P DEFAYE Pacemaker longevity in patients implanted for sinus node disease or atrio-ventricular block: a post-hoc analysis of the ANSWER study. European Heart rythm Association, 2015. P584. JAHANGIR, A., SHEN, W.-K., NEUBAUER, S. A., BALLARD, D. J., HAMMILL, S. C., HODGE, D. O., LOHSE, C. M., GERSH, B. J. & HAYES, D. L. 1999. Relation between mode of pacing and long-term survival in the very elderly. Journal of the American College of Cardiology, 33, 1208-1216. JAMIL, H. A., GIERULA, J., PATON, M. F., BYROM, R., LOWRY, J. E., CUBBON, R. M., CAIRNS, D. A., KEARNEY, M. T. & WITTE, K. K. 2016. Chronotropic incompetence does not limit exercise capacity in chronic heart failure. Journal of the American College of Cardiology, 67, 1885-1896. JELIĆ, V., BELKIĆ, K., DJORDJEVIĆ, M. & KOCOVIĆ, D. 1992. Survival in 1,431 pacemaker patients: prognostic factors and comparison with the general population. Pacing and Clinical Electrophysiology, 15, 141-147. JIANG, Z., CONNOLLY, A. & MANGHARAM, R. Using the virtual heart model to validate the mode-switch pacemaker operation. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 2010. IEEE, 6690-6693. JOHANSSON, B. W. 1966. Complete heart block. A clinical, hemodynamic and pharmacological study in patients with and without an artificial pacemaker. Acta medica Scandinavica. Supplementum, 451, 1. JONES, S., CARLEY, S. & HARRISON, M. 2003. An introduction to power and sample size estimation. Emergency medicine journal: EMJ, 20, 453. KAMALVAND, K., TAN, K., KOTSAKIS, A., BUCKNALL, C. & SULKE, N. 1997. Is mode switching beneficial? A randomized study in patients with paroxysmal atrial tachyarrhythmias. Journal of the American College of Cardiology, 30, 496-504. KAYE, G. C., LINKER, N. J., MARWICK, T. H., POLLOCK, L., GRAHAM, L., POULIOT, E., POLONIECKI, J., GAMMAGE, M., INVESTIGATORS, P.-P. T. & KAYE, G. 2014. Effect of right ventricular pacing lead site on left ventricular function in patients with high-grade atrioventricular block: results of the Protect-Pace study. European heart journal, 36, 856-862. KENNY, T. 2005. The nuts and bolts of cardiac pacing, Wiley Online Library. KIEHL, E. L., MAKKI, T., MATAR, R. M., JOHNSTON, D. R., RICKARD, J. W., TARAKJI, K. G., KANJ, M., WAZNI, O. M., SALIBA, W. I. & VARMA, N. 2017. Incidence and predictors of late atrioventricular conduction recovery among patients requiring permanent pacemaker for complete heart block after cardiac surgery. Heart Rhythm, 14, 1786-1792. KIM, S.-H., OH, Y.-S., NAM, G.-B., CHOI, K.-J., PARK, J. S., PARK, S. W., PARK, S.-J., ON, Y. K., KIM, J. S. & SHIN, W.-S. 2014. Paced QRS axis as a predictor of pacing-induced left ventricular dysfunction. Journal of Interventional Cardiac Electrophysiology, 41, 223-229. KINDERMANN, M., SCHWAAB, B., BERG, M. & FRÖHLIG, G. 2001. Longevity of dual chamber pacemakers: device and patient related determinants. Pacing and clinical electrophysiology, 24, 810-815. KONSTAM, M. A., UDELSON, J. E., ANAND, I. S. & COHN, J. N. 2003. Ventricular remodeling in heart failure: a credible surrogate endpoint. Journal of cardiac failure, 9, 350-353. KOU, S., CABALLERO, L., DULGHERU, R., VOILLIOT, D., DE SOUSA, C., KACHARAVA, G., ATHANASSOPOULOS, G. D., BARONE, D., BARONI, M. & CARDIM, N. 2014. Echocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study. European Heart Journal–Cardiovascular Imaging, 15, 680-690. KRAMER, D. G., TRIKALINOS, T. A., KENT, D. M., ANTONOPOULOS, G. V., KONSTAM, M. A. & UDELSON, J. E. 2010. Quantitative Evaluation of Drug or Device Effects on Ventricular Remodeling as Predictors of Therapeutic Effects on Mortality in Patients With Heart Failure and Reduced Ejection Fraction: A Meta-Analytic Approach. Journal of the American College of Cardiology, 56, 392-406. KRONBORG, M. B., MORTENSEN, P. T., GERDES, J. C., JENSEN, H. K. & NIELSEN, J. C. 2011. His and para-His pacing in AV block: feasibility and electrocardiographic findings. Journal of interventional cardiac electrophysiology, 31, 255. KROON, W., LUMENS, J., POTSE, M., SUERDER, D., KLERSY, C., REGOLI, F., MURZILLI, R., MOCCETTI, T., DELHAAS, T. & KRAUSE, R. 2015. In vivo electromechanical assessment of heart failure patients with prolonged QRS duration. Heart Rhythm, 12, 1259-1267. KUMAR, V., YAMADA, T. & DOPPALAPUDI, H. 2016. Discordance between Auto Mode Switch (AMS) Episodes and Atrial Tachyarrhythmia (AT/AF) Burden. Pacing and Clinical Electrophysiology, 39, 398-400. KUSUMOTO, F. M., SCHOENFELD, M. H., BARRETT, C., EDGERTON, J. R., ELLENBOGEN, K. A., GOLD, M. R., GOLDSCHLAGER, N. F., HAMILTON, R. M., JOGLAR, J. A. & KIM, R. J. 2019. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines, and the Heart Rhythm Society. Circulation, 140, e333-e381. KUTYIFA, V., STOCKBURGER, M., DAUBERT, J. P., HOLMQVIST, F., OLSHANSKY, B., SCHUGER, C., KLEIN, H., GOLDENBERG, I., BRENYO, A. & MCNITT, S. 2014. PR Interval Identifies Clinical Response in Patients With Non–Left Bundle Branch BlockCLINICAL PERSPECTIVE: A Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy Substudy. Circulation: Arrhythmia and Electrophysiology, 7, 645-651. LAMAS, G., LEE, K., SWEENEY, M., SILVERMAN, R., LEON, A., YEE, R., MARINCHAK, R., FLAKER, G., SCHRON, E. & ORAV, E. 2002. Mode Selection Trial in Sinus-Node Dysfunction. Ventricular pacing or dual-chamber pacing for sinus-node dysfunction. N Engl J Med, 346, 1854-1862. LAMAS, G. A., ORAV, E. J., STAMBLER, B. S., ELLENBOGEN, K. A., SGARBOSSA, E. B., HUANG, S. K. S., MARINCHAK, R. A., ESTES, N. M., MITCHELL, G. F. & LIEBERMAN, E. H. 1998. Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing. New England Journal of Medicine, 338, 1097-1104. LANG, R. M., BADANO, L. P., MOR-AVI, V., AFILALO, J., ARMSTRONG, A., ERNANDE, L., FLACHSKAMPF, F. A., FOSTER, E., GOLDSTEIN, S. A. & KUZNETSOVA, T. 2015. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. European Heart Journal-Cardiovascular Imaging, 16, 233-271. LAU, C. P., RUSHBY, J., LEIGH‐JONES, M., TAM, C., POLONIECKI, J., INGRAM, A., SUTTON, R. & CAMM, A. 1989. Symptomatology and quality of life in patients with rate‐responsive pacemakers: A double‐blind, randomized, crossover study. Clinical cardiology, 12, 505-512. LAU, E. W. 2007. Upper body venous access for transvenous lead placement—review of existent techniques. Pacing and clinical electrophysiology, 30, 901-909. LAU, E. W. 2017. Technologies for prolonging cardiac implantable electronic device longevity. Pacing and Clinical Electrophysiology, 40, 75-96. LEE, M. A., DAE, M. W., LANGBERG, J. J., GRIFFIN, J. C., CHIN, M. C., FINKBEINER, W. E., O'CONNELL, J. W., BOTVINICK, E., SCHEINMAN, M. M. & ROSENQVIST, M. 1994. Effects of long-term right ventricular apical pacing on left ventricular perfusion, innervation, function and histology. Journal of the American College of Cardiology, 24, 225-232. LEITMAN, M., LYSYANSKY, P., SIDENKO, S., SHIR, V., PELEG, E., BINENBAUM, M., KALUSKI, E., KRAKOVER, R. & VERED, Z. 2004. Two-dimensional strain–a novel software for real-time quantitative echocardiographic assessment of myocardial function. Journal of the American Society of Echocardiography, 17, 1021-1029. LEUNG, S.-K. & LAU, C.-P. 2000. Developments in sensor-driven pacing. Cardiology clinics, 18, 113-155. LIEBERMAN, R., PADELETTI, L., SCHREUDER, J., JACKSON, K., MICHELUCCI, A., COLELLA, A., EASTMAN, W., VALSECCHI, S. & HETTRICK, D. A. 2006. Ventricular pacing lead location alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction. J Am Coll Cardiol, 48, 1634-41. LINDEMANS, F. W. & DENIER VAN DER GON, J. J. 1978. Current thresholds and liminal size in excitation of heart muscle. Cardiovascular research, 12, 477-485. MAFI-RAD, M., LUERMANS, J. G., BLAAUW, Y., JANSSEN, M., CRIJNS, H. J., PRINZEN, F. W. & VERNOOY, K. 2016. Feasibility and acute hemodynamic effect of left ventricular septal pacing by transvenous approach through the interventricular septum. Circulation: Arrhythmia and Electrophysiology, 9, e003344. MALLELA, V. S., ILANKUMARAN, V. & RAO, N. S. 2004. Trends in cardiac pacemaker batteries. Indian pacing and electrophysiology journal, 4, 201. MANOLIS, A. S. & MELITA, H. 2017. Prevention of cardiac implantable electronic device infections: single operator technique with use of povidone‐iodine, double gloving, meticulous aseptic/antiseptic measures and antibiotic prophylaxis. Pacing and Clinical Electrophysiology, 40, 26-34. MANSOUR, F. & KHAIRY, P. 2012. Electrical storm due to managed ventricular pacing. Heart Rhythm, 9, 842-843. MARTENS, P., DEFERM, S., BERTRAND, P. B., VERBRUGGE, F. H., RAMAEKERS, J., VERHAERT, D., DUPONT, M., VANDERVOORT, P. M. & MULLENS, W. 2020. The detrimental effect of RA pacing on LA function and clinical outcome in cardiac resynchronization therapy. JACC: Cardiovascular Imaging, 13, 895-906. MARTENS, P., NUYENS, D., RIVERO-AYERZA, M., VAN HERENDAEL, H., VERCAMMEN, J., CEYSSENS, W., LUWEL, E., DUPONT, M. & MULLENS, W. 2019. Sacubitril/valsartan reduces ventricular arrhythmias in parallel with left ventricular reverse remodeling in heart failure with reduced ejection fraction. Clinical Research in Cardiology, 108, 1074-1082. MARTINELLI, F. M., DE SIQUEIRA, S., COSTA, R., GRECO, O., MOREIRA, L., D'AVILA, A. & HEIST, E. 2010. Conventional versus biventricular pacing in heart failure and bradyarrhythmia: the COMBAT study. Journal of cardiac failure, 16, 293. MARWICK, T. H. 2006. Measurement of strain and strain rate by echocardiography: ready for prime time? Journal of the American College of Cardiology, 47, 1313-1327. MAYOSI, B. M., LITTLE, F. & MILLAR, R. N. S. 1999. Long‐term survival after permanent pacemaker implantation in young adults: 30 year experience. Pacing and clinical electrophysiology, 22, 407-412. MCMANUS, D. D., SHAH, S. J., FABI, M. R., ROSEN, A., WHOOLEY, M. A. & SCHILLER, N. B. 2009. Prognostic value of left ventricular end-systolic volume index as a predictor of heart failure hospitalization in stable coronary artery disease: data from the Heart and Soul Study. Journal of the American Society of Echocardiography, 22, 190-197. MCMEEKIN, J. D., LAUTNER, D., HANSON, S. & GULAMHUSEIN, S. S. 1990. Importance of heart rate response during exercise in patients using atrioventricular synchronous and ventricular pacemakers. Pacing and Clinical Electrophysiology, 13, 59-68. MCMURRAY, J. J., PACKER, M., DESAI, A. S., GONG, J., LEFKOWITZ, M. P., RIZKALA, A. R., ROULEAU, J., SHI, V. C., SOLOMON, S. D. & SWEDBERG, K. 2013. Dual angiotensin receptor and neprilysin inhibition as an alternative to angiotensin‐converting enzyme inhibition in patients with chronic systolic heart failure: rationale for and design of the Prospective comparison of ARNI with ACEI to Determine Impact on Global Mortality and morbidity in Heart Failure trial (PARADIGM‐HF). European journal of heart failure, 15, 1062-1073. MEDTRONIC. 2020. Our Pacemakers for Bradycardia. [Online]. Available: https://www.medtronic.com/us-en/patients/treatments-therapies/pacemakers/our.html. [Accessed 01/03/2020 2020]. MIGNOT, A., DONAL, E., ZAROUI, A., REANT, P., SALEM, A., HAMON, C., MONZY, S., ROUDAUT, R., HABIB, G. & LAFITTE, S. 2010. Global longitudinal strain as a major predictor of cardiac events in patients with depressed left ventricular function: a multicenter study. Journal of the American Society of Echocardiography, 23, 1019-1024. MOND, H. G. 1999. Recent advances in pacemaker lead technology. Cardiac Electrophysiology Review, 3, 5-9. MOND, H. G. 2001. The world survey of cardiac pacing and cardioverter defibrillators: Calendar year 1997‐Asian Pacific, Middle East, South America, and Canada. Pacing and Clinical Electrophysiology, 24, 856-862. MOND, H. G. & PROCLEMER, A. 2011a. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009--a World Society of Arrhythmia's project. Pacing Clin Electrophysiol, 34, 1013-27. MOND, H. G. & PROCLEMER, A. 2011b. The 11th world survey of cardiac pacing and implantable cardioverter‐defibrillators: calendar year 2009–a World Society of Arrhythmia's project. Pacing and clinical electrophysiology, 34, 1013-1027. MORGAN, K., MCGEE, H. & SHELLEY, E. 2007. Quality of life assessment in heart failure interventions: a 10-year (1996–2005) review. European Journal of Cardiovascular Prevention & Rehabilitation, 14, 589-607. MORRIS‐THURGOOD, J., CHIANG, C. M., ROGHELLE, J., STEINHAUS, B., ILSLEY, C. & PAUL, V. 1994. A rate responsive pacemaker that physiologically reduces pacing rates at rest. Pacing and Clinical Electrophysiology, 17, 1928-1932. MULPURU, S. K., MADHAVAN, M., MCLEOD, C. J., CHA, Y.-M. & FRIEDMAN, P. A. 2017. Cardiac pacemakers: function, troubleshooting, and management: part 1 of a 2-part series. Journal of the American College of Cardiology, 69, 189-210. MURGATROYD, F. D., HELMLING, E., LEMKE, B., EBER, B., MEWIS, C., VAN DER MEER-HENSGENS, J., CHANG, Y., KHALAMEIZER, V. & KATZ, A. 2010. Manual vs. automatic capture management in implantable cardioverter defibrillators and cardiac resynchronization therapy defibrillators. Europace, 12, 811-6. NAGY, K. V., SZÉPLAKI, G., BOROS, A. M., PERGE, P., APOR, A., KOSZTIN, A., MOLNÁR, L., GELLÉR, L. & MERKELY, B. 2017. QUALITY OF LIFE MEASURED WITH EUROQOL-5D QUESTIONNAIRE PREDICTS LONG TERM MORTALITY AND ECHOCARDIOGRAPHIC RESPONSE IN CRT PATIENTS. Journal of the American College of Cardiology, 69, 813. NELSON, G. 1993. A brief history of cardiac pacing. Texas Heart Institute Journal, 20, 12. NG, A. C., ALLMAN, C., VIDAIC, J., TIE, H., HOPKINS, A. P. & LEUNG, D. Y. 2009. Long-term impact of right ventricular septal versus apical pacing on left ventricular synchrony and function in patients with second-or third-degree heart block. American Journal of Cardiology, 103, 1096-1101. NICE 2014a. Dual-chamber pacemakers for symptomatic bradycardia due to sick sinus syndrome without atrioventricular block (TA324). In: EXCELLENCE, N. I. F. H. A. C. (ed.). London: NICE. NICE 2014b. Dual‑chamber pacemakers for symptomatic bradycardia due to sick sinus syndrome and/or atrioventricular block Technology appraisal guidance [TA88]. In: EXCELLENCE, N. I. F. H. A. C. (ed.). NICE 2017. Dual-chamber pacemakers for symptomatic bradycardia due to sick sinus syndrome and/or atrioventricular block. NICOR 2016. National Audit of Cardiac Rhythm Management Devices. NICOR 2019. National Audit of Cardiac Rhythm Management Device and Ablation. In: RESEARCH, N. I. F. C. O. (ed.). NIELSEN, J. C., BØTTCHER, M., NIELSEN, T. T., PEDERSEN, A. K. & ANDERSEN, H. R. 2000. Regional myocardial blood flow in patients with sick sinus syndrome randomized to long-term single chamber atrial or dual chamber pacing—effect of pacing mode and rate. Journal of the American College of Cardiology, 35, 1453-1461. NIELSEN, J. C., KRISTENSEN, L., ANDERSEN, H. R., MORTENSEN, P. T., PEDERSEN, O. L. & PEDERSEN, A. K. 2003. A randomized comparison ofatrial and dual-chamber pacing in177 consecutive patients with sick sinus syndrome: Echocardiographic and clinical outcome. Journal of the American College of Cardiology, 42, 614-623. NIELSEN, J. C., THOMSEN, P. E. B., HØJBERG, S., MØLLER, M., RIAHI, S., DALSGAARD, D., MORTENSEN, L. S., NIELSEN, T., ASKLUND, M. & FRIIS, E. V. 2012. Atrial fibrillation in patients with sick sinus syndrome: the association with PQ-interval and percentage of ventricular pacing. Europace, 14, 682-689. NIELSEN, J. C., THOMSEN, P. E. B., HØJBERG, S., MØLLER, M., VESTERLUND, T., DALSGAARD, D., MORTENSEN, L. S., NIELSEN, T., ASKLUND, M. & FRIIS, E. V. 2011. A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome. European heart journal, 32, 686-696. NUTTER, D. 1978. Measuring and recording systemic blood pressure. The heart, 4, 220-2. OCCHETTA, E., BORTNIK, M., MAGNANI, A., FRANCALACCI, G., PICCININO, C., PLEBANI, L. & MARINO, P. 2006. Prevention of ventricular desynchronization by permanent para-Hisian pacing after atrioventricular node ablation in chronic atrial fibrillation: a crossover, blinded, randomized study versus apical right ventricular pacing. Journal of the American College of Cardiology, 47, 1938-1945. OWAN, T. E., HODGE, D. O., HERGES, R. M., JACOBSEN, S. J., ROGER, V. L. & REDFIELD, M. M. 2006. Trends in prevalence and outcome of heart failure with preserved ejection fraction. New England Journal of Medicine, 355, 251-259. PACKER, M., ANTONOPOULOS, G. V., BERLIN, J. A., CHITTAMS, J., KONSTAM, M. A. & UDELSON, J. E. 2001. Comparative effects of carvedilol and metoprolol on left ventricular ejection fraction in heart failure: results of a meta-analysis. American heart journal, 141, 899-907. PADELETTI, L., PIERAGNOLI, P., DI BIASE, L., COLELLA, A., LANDOLINA, M., MORO, E., ORAZI, S., VICENTINI, A., MAGLIA, G. & PENSABENE, O. 2006. Is a dual‐sensor pacemaker appropriate in patients with sino‐atrial disease? Results from the DUSISLOG study. Pacing and clinical electrophysiology, 29, 34-40. PAP, R., GALLARDO, R., RÓNASZÉKI, D., ÁGOSTON, G., TRAYKOV, V. B., SÁGHY, L., VARGA, A. & FORSTER, T. 2012. The role of pacing-induced dyssynchrony in left ventricular remodeling associated with long-term right ventricular pacing for atrioventricular block. Journal of electrocardiology, 45, 357-360. PARK, J. J., PARK, J.-B., PARK, J.-H. & CHO, G.-Y. 2018. Global longitudinal strain to predict mortality in patients with acute heart failure. Journal of the American College of Cardiology, 71, 1947-1957. PASCALE, P., PRUVOT, E. & GRAF, D. 2009. Pacemaker syndrome during managed ventricular pacing mode: what is the mechanism? Journal of cardiovascular electrophysiology, 20, 574-576. PATON, M. F., LANDOLINA, M., BILLUART, J.-R., FIELD, D., SIBLEY, J. & WITTE, K. 2019. Projected longevities of cardiac implantable defibrillators: a retrospective analysis over the period 2007–17 and the impact of technological factors in determining longevity. EP Europace. PERNEGER, T. V. 1998. What's wrong with Bonferroni adjustments. Bmj, 316, 1236-1238. PLOUX, S., LUMENS, J., WHINNETT, Z., MONTAUDON, M., STROM, M., RAMANATHAN, C., DERVAL, N., ZEMMOURA, A., DENIS, A. & DE GUILLEBON, M. 2013. Noninvasive electrocardiographic mapping to improve patient selection for cardiac resynchronization therapy: beyond QRS duration and left bundle branch block morphology. Journal of the American College of Cardiology, 61, 2435-2443. PONIKOWSKI, P., VOORS, A. A., ANKER, S. D., BUENO, H., CLELAND, J. G., COATS, A. J., FALK, V., GONZÁLEZ‐JUANATEY, J. R., HARJOLA, V. P. & JANKOWSKA, E. A. 2016. 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC). Developed with the special contribution of the Heart Failure Association (HFA) of the ESC. European journal of heart failure, 18, 891-975. POTTER, E. & MARWICK, T. H. 2018. Assessment of left ventricular function by echocardiography: the case for routinely adding global longitudinal strain to ejection fraction. JACC: Cardiovascular Imaging, 11, 260-274. PRINZEN, F. W., HUNTER, W. C., WYMAN, B. T. & MCVEIGH, E. R. 1999. Mapping of regional myocardial strain and work during ventricular pacing: experimental study using magnetic resonance imaging tagging. J Am Coll Cardiol, 33, 1735-42. RAATIKAINEN, M. P., ARNAR, D. O., ZEPPENFELD, K., MERINO, J. L., LEVYA, F., HINDRIKS, G. & KUCK, K.-H. 2015. Statistics on the use of cardiac electronic devices and electrophysiological procedures in the European Society of Cardiology countries: 2014 report from the European Heart Rhythm Association. Ep Europace, 17, i1-i75. RAJAPPAN, K. 2009a. Permanent pacemaker implantation technique: part I. Heart, 95, 259-264. RAJAPPAN, K. 2009b. Permanent pacemaker implantation technique: part II. Heart, 95, 334-342. RANGANATHAN, N., DHURANDHAR, R., PHILLIPS, J. & WIGLE, E. 1972. His Bundle electrogram in bundle-branch block. Circulation, 45, 282-294. RASMUSSEN, K. 1981. Chronic sinus node disease: natural course and indications for pacing. European heart journal, 2, 455-459. RICCI, R. P., BOTTO, G. L., BÉNÉZET, J. M., NIELSEN, J. C., DE ROY, L., PIOT, O., QUESADA, A., QUAGLIONE, R., VACCARI, D. & MANGONI, L. 2015. Association between ventricular pacing and persistent atrial fibrillation in patients indicated to elective pacemaker replacement: Results of the Prefer for Elective Replacement MVP (PreFER MVP) randomized study. Heart Rhythm, 12, 2239-2246. RIEGEL, B., MOSER, D. K., GLASER, D., CARLSON, B., DEATON, C., ARMOLA, R., SETHARES, K., SHIVELY, M., EVANGELISTA, L. & ALBERT, N. 2002. The Minnesota Living With Heart Failure Questionnaire: sensitivity to differences and responsiveness to intervention intensity in a clinical population. Nursing research, 51, 209-218. ROBERTS, P. R. 2005. Follow up and optimisation of cardiac pacing. Heart, 91, 1229-1234. RUBAJ, A., RUCINSKI, P., SODOLSKI, T., BILAN, A., GULAJ, M., DABROWSKA‐KUGACKA, A. & KUTARSKI, A. 2010. Comparison of the Acute Hemodynamic Effect of Right Ventricular Apex, Outflow Tract, and Dual‐Site Right Ventricular Pacing. Annals of Noninvasive Electrocardiology, 15, 353-359. SAITO, M., KAYE, G., NEGISHI, K., LINKER, N., GAMMAGE, M., KOSMALA, W. & MARWICK, T. H. 2015. Dyssynchrony, contraction efficiency and regional function with apical and non-apical RV pacing. Heart, 101, 600-608. SARVARI, S. I., SITGES, M., SANZ, M., TOLOSANA VIU, J. M., EDVARDSEN, T., STOKKE, T. M., MONT, L. & BIJNENS, B. 2017. Left ventricular dysfunction is related to the presence and extent of a septal flash in patients with right ventricular pacing. EP Europace, 19, 289-296. SASAKI, Y., SHIMOTORI, M., AKAHANE, K., YONEKURA, H., HIRANO, K., ENDOH, R., KOIKE, S., KAWA, S., FURUTA, S. & HOMMA, T. 1988. Long‐term follow‐up of patients with sick sinus syndrome: A comparison of clinical aspects among unpaced, ventricular inhibited paced, and physiologically paced groups. Pacing and Clinical Electrophysiology, 11, 1575-1583. SAUNDERSON, C. P., MF; GIERULA, J; BROWN, LAE; GREENWOOD, JP; KOSHY, A; CRAVEN, TP; CHEW, P; DA,S A; LEVELT, E; DALL’ARMELLINA, E; WITTE, KK; PLEIN, S AND SWOBODA, P. 2019. Prevalence and distribution of cardiac fibrosis in patients with atrioventricular block undergoing pacemaker implantation. European Journal of Arrhythmia and Electrophysiology, 5, abstr.59. SAVOURE, A., FROHLIG, G., GALLEY, D., DEFAYE, P., REUTER, S., MABO, P., SADOUL, N., AMBLARD, A., LIMOUSIN, M. & ANSELME, F. 2005. A new dual-chamber pacing mode to minimize ventricular pacing. Pacing Clin Electrophysiol, 28 Suppl 1, S43-6. SCHWAAB, B., FRÖHLIG, G., SCHWERDT, H., HEISEL, A., BERG, M. & SCHIEFFER, H. 1998. Telemetry guided pacemaker programming: impact of output amplitude and the use of low threshold leads on projected pacemaker longevity. Pacing and clinical electrophysiology, 21, 2055-2063. SHARMA, A. D., RIZO-PATRON, C., HALLSTROM, A. P., O’NEILL, G. P., ROTHBART, S., MARTINS, J. B., ROELKE, M., STEINBERG, J. S., GREENE, H. L. & INVESTIGATORS, D. 2005. Percent right ventricular pacing predicts outcomes in the DAVID trial. Heart rhythm, 2, 830-834. SHEN, W.-K., HAMMILL, S. C., HAYES, D. L., PACKER, D. L., BAILEY, K. R., BALLARD, D. J. & GERSH, B. J. 1994. Long-term survival after pacemaker implantation for heart block in patients≥ 65 years. The American journal of cardiology, 74, 560-564. SHEN, W.-K., HAYES, D. L., HAMMILL, S. C., BAILEY, K. R., BALLARD, D. J. & GERSH, B. J. 1996. Survival and functional independence after implantation of a permanent pacemaker in octogenarians and nonagenarians: a population-based study. Annals of internal medicine, 125, 476-480. SHUKLA, H. H., HELLKAMP, A. S., JAMES, E. A., FLAKER, G. C., LEE, K. L., SWEENEY, M. O. & LAMAS, G. A. 2005. Heart failure hospitalization is more common in pacemaker patients with sinus node dysfunction and a prolonged paced QRS duration. Heart Rhythm, 2, 245-251. SILVERMAN, B. G., GROSS, T. P., KACZMAREK, R. G., HAMILTON, P. & HAMBURGER, S. 1995. The epidemiology of pacemaker implantation in the United States. Public Health Reports, 110, 42. SIMANTIRAKIS, E. N., KOCHIADAKIS, G. E., VARDAKIS, K. E., IGOUMENIDIS, N. E., CHRYSOSTOMAKIS, S. I. & VARDAS, P. E. 2003. Left ventricular mechanics and myocardial blood flow following restoration of normal activation sequence in paced patients with long-term right ventricular apical stimulation. Chest, 124, 233-241. STAMBLER, B. S., ELLENBOGEN, K. A., ZHANG, X., PORTER, T. R., XIE, F., MALIK, R., SMALL, R., BURKE, M., KAPLAN, A. & NAIR, L. 2003. Right ventricular outflow versus apical pacing in pacemaker patients with congestive heart failure and atrial fibrillation. Journal of cardiovascular electrophysiology, 14, 1180-1186. STANTON, T., LEANO, R. & MARWICK, T. H. 2009. Prediction of all-cause mortality from global longitudinal speckle strain: comparison with ejection fraction and wall motion scoring. Circulation: Cardiovascular Imaging, 2, 356-364. STEFANI, L., TONCELLI, L., GIANASSI, M., MANETTI, P., DI TANTE, V., VONO, M. R. C., MORETTI, A., CAPPELLI, B., PEDRIZZETTI, G. & GALANTI, G. 2007. Two-dimensional tracking and TDI are consistent methods for evaluating myocardial longitudinal peak strain in left and right ventricle basal segments in athletes. Cardiovascular ultrasound, 5, 7. STOCKBURGER, M., BOVEDA, S., MORENO, J., DA COSTA, A., HATALA, R., BRACHMANN, J., BUTTER, C., GARCIA SEARA, J., ROLANDO, M. & DEFAYE, P. 2014. Long-term clinical effects of ventricular pacing reduction with a changeover mode to minimize ventricular pacing in a general pacemaker population. European heart journal, 36, 151-157. STOCKBURGER, M., DEFAYE, P., BOVEDA, S., STANCAK, B., LAZARUS, A., SIPÖTZ, J., NARDI, S., ROLANDO, M. & MORENO, J. 2015. Safety and efficiency of ventricular pacing prevention with an AAI-DDD changeover mode in patients with sinus node disease or atrioventricular block: impact on battery longevity—a sub-study of the ANSWER trial. Ep Europace, 18, 739-746. STOKES, K. 1985. The electrode-biointerface: stimulation. Modern cardiac pacing., 33-77. SULKE, N., CHAMBERS, J., DRITSAS, A. & SOWTON, E. 1991. A randomized double-blind crossover comparison of four rate-responsive pacing modes. Journal of the American College of Cardiology, 17, 696-706. SWEENEY, M. 2007. Search AV Extension and Managed Ventricular Pacing for Promoting Atrioventricular Conduction (SAVE PACe) Trial. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. N Engl J Med, 357, 1000-1008. SWEENEY, M. O., BANK, A. J., NSAH, E., KOULLICK, M., ZENG, Q. C., HETTRICK, D., SHELDON, T. & LAMAS, G. A. 2007. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. New England Journal of Medicine, 357, 1000-1008. SWEENEY, M. O., ELLENBOGEN, K. A., CASAVANT, D., BETZOLD, R., SHELDON, T., TANG, F., MUELLER, M., LINGLE, J. & INVESTIGATORS, M. M. D. 2005a. Multicenter, prospective, randomized safety and efficacy study of a new atrial‐based managed ventricular pacing mode (MVP) in dual chamber ICDs. Journal of cardiovascular electrophysiology, 16, 811-817. SWEENEY, M. O., ELLENBOGEN, K. A., TANG, A. S., WHELLAN, D., MORTENSEN, P. T., GIRALDI, F., SANDLER, D. A., SHERFESEE, L., SHELDON, T. & VVI, M. V. P. V. 2010. Atrial pacing or ventricular backup–only pacing in implantable cardioverter-defibrillator patients. Heart Rhythm, 7, 1552-1560. SWEENEY, M. O., HELLKAMP, A. S., ELLENBOGEN, K. A., GREENSPON, A. J., FREEDMAN, R. A., LEE, K. L. & LAMAS, G. A. 2003. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation, 107, 2932-2937. SWEENEY, M. O., HELLKAMP, A. S., ELLENBOGEN, K. A. & LAMAS, G. A. 2008. Reduced ejection fraction, sudden cardiac death, and heart failure death in the mode selection trial (MOST): implications for device selection in elderly patients with sinus node disease. Journal of cardiovascular electrophysiology, 19, 1160-1166. SWEENEY, M. O., HELLKAMP, A. S., LEE, K. L. & LAMAS, G. A. 2005b. Association of prolonged QRS duration with death in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation, 111, 2418-2423. SWEENEY, M. O. & PRINZEN, F. W. 2006. A new paradigm for physiologic ventricular pacing. J Am Coll Cardiol, 47, 282-8. TAYAL, B., FRUELUND, P., SOGAARD, P., RIAHI, S., POLCWIARTEK, C., ATWATER, B. D., GISLASON, G., RISUM, N., TORP-PEDERSEN, C. & KOBER, L. 2019. Incidence of heart failure after pacemaker implantation: a nationwide Danish Registry-based follow-up study. European heart journal, 40, 3641-3648. THACKRAY, S. D., WITTE, K. K., NIKITIN, N. P., CLARK, A. L., KAYE, G. C. & CLELAND, J. G. 2003. The prevalence of heart failure and asymptomatic left ventricular systolic dysfunction in a typical regional pacemaker population. European Heart Journal, 24, 1143-1152. TOFF, W. D., CAMM, A. J. & SKEHAN, J. D. 2005. Single-chamber versus dual-chamber pacing for high-grade atrioventricular block. New England Journal of Medicine, 353, 145-155. TOPS, L. F., SCHALIJ, M. J., HOLMAN, E. R., VAN ERVEN, L., VAN DER WALL, E. E. & BAX, J. J. 2006. Right ventricular pacing can induce ventricular dyssynchrony in patients with atrial fibrillation after atrioventricular node ablation. J Am Coll Cardiol, 48, 1642-8. TORRES-AYALA, S. C., SANTACANA-LAFFITTE, G. & MALDONADO, J. 2014. Radiography of cardiac conduction devices: a pictorial review of pacemakers and implantable cardioverter defibrillators. Journal of clinical imaging science, 4. TRAPPE, H.-J., KLEIN, H., FRANK, G. & LICHTEN, P. 1988. Rate-responsive pacing as compared to fixed-rate VVI pacing in patients after ablation of the atrioventricular conduction system. European heart journal, 9, 642-648. TRIAL, S.-H. 1999. CIBIS-II Trial. Lancet, 353, 9-13. TSE, H.-F. & LAU, C.-P. 1997a. Long-term effect of right ventricular pacing on myocardial perfusion and function. Journal of the American College of Cardiology, 29, 744-749. TSE, H.-F., YU, C., WONG, K.-K., TSANG, V., LEUNG, Y.-L., HO, W.-Y. & LAU, C.-P. 2002. Functional abnormalities in patients with permanent right ventricular pacing: the effect of sites of electrical stimulation. Journal of the American College of Cardiology, 40, 1451-1458. TSE, H. F. & LAU, C. P. 1997b. Long-term effect of right ventricular pacing on myocardial perfusion and function. J Am Coll Cardiol, 29, 744-9. TYERS, G. 2011. Actual pacemaker longevity: the benefit of stimulation by automatic capture verification. Pacing and clinical electrophysiology: PACE, 34, 389; author reply 389-90. UDO, E. O., VAN HEMEL, N. M., ZUITHOFF, N. P., DIJK, W. A., HOOIJSCHUUR, C. A., DOEVENDANS, P. A. & MOONS, K. G. 2013. Pacemaker follow-up: are the latest guidelines in line with modern pacemaker practice? Europace, 15, 243-251. UDO, E. O., VAN HEMEL, N. M., ZUITHOFF, N. P., DOEVENDANS, P. A. & MOONS, K. G. 2015. Risk of heart failure-and cardiac death gradually increases with more right ventricular pacing. International journal of cardiology, 185, 95-100. USLAN, D. Z., GLEVA, M. J., WARREN, D. K., MELA, T., CHUNG, M. K., GOTTIPATY, V., BORGE, R., DAN, D., SHINN, T. & MITCHELL, K. 2012. Cardiovascular implantable electronic device replacement infections and prevention: results from the REPLACE Registry. Pacing and Clinical Electrophysiology, 35, 81-87. VAN DE VEN, L. L., VAN VELDHUISEN, D. J., GOULDER, M., ZILAHI, Z., MEYER, W. R. & WILLENHEIMER, R. 2010. The effect of treatment with bisoprolol-first versus enalapril-first on cardiac structure and function in heart failure. International journal of cardiology, 144, 59-63. VAN ECK, J. M., VAN HEMEL, N. M., VAN DEN BOS, A., TAKS, W., GROBBEE, D. E. & MOONS, K. G. 2008a. Predictors of improved quality of life 1 year after pacemaker implantation. American heart journal, 156, 491-497. VAN ECK, J. W., VAN HEMEL, N. M., DE VOOGT, W. G., MEEDER, J. G., SPIERENBURG, H. A., CROMMENTUYN, H., KEIJZER, R., GROBBEE, D. E. & MOONS, K. G. 2008b. Routine follow-up after pacemaker implantation: frequency, pacemaker programming and professionals in charge. Europace, 10, 832-837. VAN GELDORP, I. E., DELHAAS, T., GEBAUER, R. A., FRIAS, P., TOMASKE, M., FRIEDBERG, M. K., TISMA-DUPANOVIC, S., ELDERS, J., FRÜH, A. & GABBARINI, F. 2011. Impact of the permanent ventricular pacing site on left ventricular function in children: a retrospective multicentre survey. Heart, heartjnl-2011-300197. VAN OOSTERHOUT, M. F., PRINZEN, F. W., ARTS, T., SCHREUDER, J. J., VANAGT, W. Y., CLEUTJENS, J. P. & RENEMAN, R. S. 1998. Asynchronous electrical activation induces asymmetrical hypertrophy of the left ventricular wall. Circulation, 98, 588-595. VANVOORHIS, C. W. & MORGAN, B. L. 2007. Understanding power and rules of thumb for determining sample sizes. Tutorials in quantitative methods for psychology, 3, 43-50. VARDAS, P. E., AURICCHIO, A., BLANC, J.-J., DAUBERT, J.-C., DREXLER, H., ECTOR, H., GASPARINI, M., LINDE, C., MORGADO, F. B. & OTO, A. 2007. Guidelines for cardiac pacing and cardiac resynchronization therapy: the task force for cardiac pacing and cardiac resynchronization therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association. European heart journal, 28, 2256-2295. VICTOR, F., LECLERCQ, C., MABO, P., PAVIN, D., DEVILLER, A., DE PLACE, C., PEZARD, P., VICTOR, J. & DAUBERT, C. 1999. Optimal right ventricular pacing site in chronically implanted patients: a prospective randomized crossover comparison of apical and outflow tract pacing. Journal of the American College of Cardiology, 33, 311-316. VIJAYARAMAN, P., DANDAMUDI, G., LUSTGARTEN, D. & ELLENBOGEN, K. A. 2017. Permanent his bundle pacing: Electrophysiological and echocardiographic observations from long‐term follow‐up. Pacing and Clinical Electrophysiology. VOIGT, J.-U., EXNER, B., SCHMIEDEHAUSEN, K., HUCHZERMEYER, C., REULBACH, U., NIXDORFF, U., PLATSCH, G. N., KUWERT, T., DANIEL, W. G. & FLACHSKAMPF, F. A. 2003. Strain-rate imaging during dobutamine stress echocardiography provides objective evidence of inducible ischemia. Circulation, 107, 2120-2126. VOIGT, J.-U., PEDRIZZETTI, G., LYSYANSKY, P., MARWICK, T. H., HOULE, H., BAUMANN, R., PEDRI, S., ITO, Y., ABE, Y. & METZ, S. 2014. Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. European Heart Journal-Cardiovascular Imaging, 16, 1-11. VOIGT, J.-U., SCHNEIDER, T.-M., KORDER, S., SZULIK, M., GÜREL, E., DANIEL, W. G., RADEMAKERS, F. & FLACHSKAMPF, F. A. 2009. Apical transverse motion as surrogate parameter to determine regional left ventricular function inhomogeneities: a new, integrative approach to left ventricular asynchrony assessment. European heart journal, 30, 959-968. WEIZONG, W., ZHONGSU, W., YUJIAO, Z., MEI, G., JIANGRONG, W., YONG, Z., XINXING, X. & YINGLONG, H. 2013. Effects of right ventricular nonapical pacing on cardiac function: a meta‐analysis of randomized controlled trials. Pacing and Clinical Electrophysiology, 36, 1032-1051. WENZL, M. & MOSSIALOS, E. 2018. Prices for cardiac implant devices may be up to six times higher in the US than in some European countries. Health Affairs, 37, 1570-1577. WESSLER, B. S., KRAMER, D. G., KELLY, J. L., TRIKALINOS, T. A., KENT, D. M., KONSTAM, M. A. & UDELSON, J. E. 2011. Drug and device effects on peak oxygen consumption, 6-minute walk distance, and natriuretic peptides as predictors of therapeutic effects on mortality in patients with heart failure and reduced ejection fraction. Circulation: Heart Failure, 4, 578-588. WHARTON, G., STEEDS, R., ALLEN, J., PHILLIPS, H., JONES, R., KANAGALA, P., LLOYD, G., MASANI, N., MATHEW, T. & OXBOROUGH, D. 2015. A minimum dataset for a standard adult transthoracic echocardiogram: a guideline protocol from the British Society of Echocardiography. Echo Research and Practice, 2, G9-G24. WIGGERS, C. J. 1925. The muscular reactions of the mammalian ventricles to artificial surface stimuli. American Journal of Physiology-Legacy Content, 73, 346-378. WILD, D. M., FISHER, J. D., KIM, S. G., FERRICK, K. J., GROSS, J. N. & PALMA, E. C. 2004. Pacemakers and implantable cardioverter defibrillators: device longevity is more important than smaller size: the patient's viewpoint. Pacing and clinical electrophysiology, 27, 1526-1529. WILKOFF, B. L., AURICCHIO, A., BRUGADA, J., COWIE, M., ELLENBOGEN, K. A., GILLIS, A. M., HAYES, D. L., HOWLETT, J. G., KAUTZNER, J. & LOVE, C. J. 2008. HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs): description of techniques, indications, personnel, frequency and ethical considerations: developed in partnership with the Heart Rhythm Society (HRS) and the European Heart Rhythm Association (EHRA); and in collaboration with the American College of Cardiology (ACC), the American Heart Association (AHA), the European Society of Cardiology (ESC), the Heart Failure Association of ESC (HFA), and the Heart Failure Society of America (HFSA). Endorsed by the Heart Rhythm Society, the European Heart Rhythm Association (a registered branch of the ESC), the American College of Cardiology, the American Heart Association. Europace, 10, 707-725. WILKOFF, B. L., COOK, J. R., EPSTEIN, A. E., GREENE, H. L., HALLSTROM, A. P., HSIA, H., KUTALEK, S. P., SHARMA, A., DUAL, C. & INVESTIGATORS, V. V. I. I. D. T. 2002. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA, 288, 3115-23. WILKOFF, B. L., KUDENCHUK, P. J., BUXTON, A. E., SHARMA, A., COOK, J. R., BHANDARI, A. K., BIEHL, M., TOMASSONI, G., LEONEN, A. & KLEVAN, L. R. 2009. The DAVID (dual chamber and VVI implantable defibrillator) II trial. Journal of the American College of Cardiology, 53, 872-880. WITTE, K. K., BYROM, R., GIERULA, J., PATON, M. F., JAMIL, H. A., LOWRY, J. E., GILLOTT, R. G., BARNES, S. A., CHUMUN, H. & KEARNEY, L. C. 2016. Effects of vitamin D on cardiac function in patients with chronic HF: the VINDICATE study. Journal of the American College of Cardiology, 67, 2593-2603. WOLBER, T., HAEGELI, L., HUERLIMANN, D., BRUNCKHORST, C., LUESCHER, T. F. & DURU, F. 2011. Altered Left Ventricular Contraction Pattern during Right Ventricular Pacing: Assessment Using Real‐Time Three‐Dimensional Echocardiography. Pacing and clinical electrophysiology, 34, 76-81. WOOD, M. A. & ELLENBOGEN, K. A. 2002. Cardiac pacemakers from the patient’s perspective. Circulation, 105, 2136-2138. YINGCHONCHAROEN, T., AGARWAL, S., POPOVIĆ, Z. B. & MARWICK, T. H. 2013. Normal ranges of left ventricular strain: a meta-analysis. Journal of the American Society of Echocardiography, 26, 185-191. YU, C.-M., BLEEKER, G. B., FUNG, J. W.-H., SCHALIJ, M. J., ZHANG, Q., VAN DER WALL, E. E., CHAN, Y.-S., KONG, S.-L. & BAX, J. J. 2005. Left ventricular reverse remodeling but not clinical improvement predicts long-term survival after cardiac resynchronization therapy. Circulation, 112, 1580-1586. YU, C.-M., CHAN, J. Y.-S., ZHANG, Q., OMAR, R., YIP, G. W.-K., HUSSIN, A., FANG, F., LAM, K. H., CHAN, H. C.-K. & FUNG, J. W.-H. 2009. Biv"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.826711"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["2016-02-055"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/28397/1/PDFVersion1.2_MariaPaton_Thesis02.11.2020.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Is pacemaker-induced cardiac dysfunction progressive and reversible in patients receiving long-term pacemaker therapy?"]}]}],"canonical_facts":{"dc:contributor.advisor":["Witte, Klaus","Cairns, David"],"dc:contributor.sponsor":["NIHR"],"dc:creator":["Paton, Maria Frances"],"dc:date":["2020-08"],"dc:date.issued":["2020-08"],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.826711"],"dc:identifier.grantnumber":["2016-02-055"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/28397/1/PDFVersion1.2_MariaPaton_Thesis02.11.2020.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Faculty of Medicine and Health (Leeds)","School of Medicine (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/28397/"],"dc:relation.references":["ABDULLA, J., BARLERA, S., LATINI, R., KJOLLER‐HANSEN, L., SOGAARD, P., CHRISTENSEN, E., KOBER, L. & TORP‐PEDERSEN, C. 2007. A systematic review: effect of angiotensin converting enzyme inhibition on left ventricular volumes and ejection fraction in patients with a myocardial infarction and in patients with left ventricular dysfunction. European journal of heart failure, 9, 129-135. ADOMIAN, G. E. & BEAZELL, J. 1986. Myofibrillar disarray produced in normal hearts by chronic electrical pacing. American heart journal, 112, 79-83. AHMED, F. Z., MOTWANI, M., CUNNINGTON, C., KWOK, C. S., FULLWOOD, C., OCEANDY, D., FITCHET, A., GOODE, G. K., LUCKIE, M. & ZAIDI, A. M. 2017. One-month global longitudinal strain identifies patients who will develop pacing-induced left ventricular dysfunction over time: the pacing and ventricular dysfunction (PAVD) study. PloS one, 12, e0162072. ANDERSEN, G., GREEN, A., MADSEN, G. M. & ARNSBO, P. 1991. The epidemiology of pacemaker implantations in Fyn county, Denmark. Pacing and Clinical Electrophysiology, 14, 1614-1621. ANDERSEN, H. R., NIELSEN, J. C., THOMSEN, P. E. B., THUESEN, L., MORTENSEN, P. T., VESTERLUND, T. & PEDERSEN, A. K. 1997. Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome. The Lancet, 350, 1210-1216. ARKOLAKI, E. G., SIMANTIRAKIS, E. N., KONTARAKI, J. E., CHRYSOSTOMAKIS, S. I., PATRIANAKOS, A. P., CHLOUVERAKIS, G. I., NAKOU, E. S. & VARDAS, P. E. 2015. Alterations in the expression of genes related to contractile function and hypertrophy of the left ventricle in chronically paced patients from the right ventricular apex. Ep Europace, 17, 1563-1570. ARMSTRONG, P. W., STOPPS, T. P., FORD, S. E. & DE BOLD, A. J. 1986. Rapid ventricular pacing in the dog: pathophysiologic studies of heart failure. Circulation, 74, 1075-1084. ARONOW, W. S. & GREGORATOS, G. 1999. MANAGEMENT OF ATRIAL FIBRILLATION, VENTRICULAR ARRHYTHMIAS AND PACEMAKERS IN OLDER PERSONS: Permanent Pacemakers in Older Persons. Journal of the American Geriatrics Society, 47, 1125-1135. ARTIS, N., OXBOROUGH, D., WILLIAMS, G., PEPPER, C. & TAN, L. 2008. Two-dimensional strain imaging: a new echocardiographic advance with research and clinical applications. International journal of cardiology, 123, 240-248. AUGER, D., HOKE, U., MARSAN, N. A., TOPS, L. F., LEONG, D. P., BERTINI, M., SCHALIJ, M. J., BAX, J. J. & DELGADO, V. 2014. Effect of Induced LV Dyssynchrony by Right Ventricular Apical Pacing on All‐Cause Mortality and Heart Failure Hospitalization Rates at Long‐Term Follow‐Up. Journal of cardiovascular electrophysiology, 25, 631-637. BAROLD, S. S. 1996. Indications for permanent cardiac pacing in first‐degree AV block: class I, II, or III? Pacing and clinical electrophysiology, 19, 747-751. BAROLD, S. S. & HERWEG, B. 2012. Conventional and biventricular pacing in patients with first-degree atrioventricular block. Europace, 14, 1414-1419. BAROLD, S. S. & LEVINE, P. A. 2001. Pacemaker repetitive nonreentrant ventriculoatrial synchronous rhythm. A review. Journal of interventional cardiac electrophysiology, 5, 59-66. BAROLD, S. S. & WINNER, J. A. 1976. Techniques and Significance of Threshold Measurement for Cardiac Pacing: Relationship to Output Circuit of Cardiac Pacemakers. Chest, 70, 760-766. BATEY, R. L., SWEESY, M. W., SCALA, G. & FORNEY, R. C. 1990. Comparison of low rate dual chamber pacing to activity responsive rate variable ventricular pacing. Pacing and Clinical Electrophysiology, 13, 646-652. BEDOTTO, J. B., GRAYBURN, P. A., BLACK, W. H., RAYA, T. E., MCBRIDE, W., HSIA, H. H. & EICHHORN, E. J. 1990. Alterations in left ventricular relaxation during atrioventricular pacing in humans. Journal of the American College of Cardiology, 15, 658-664. BENKEMOUN, H., SACREZ, J., LAGRANGE, P., AMIEL, A., PRAKASH, A., HIMMRICH, E., AIME, E., MAIRESSE, G. H., GUENON, C. & SBRAGIA, P. 2012a. Optimizing pacemaker longevity with pacing mode and settings programming: results from a pacemaker multicenter registry. Pacing and clinical electrophysiology, 35, 403-408. BENKEMOUN, H., SACREZ, J., LAGRANGE, P., AMIEL, A., PRAKASH, A., HIMMRICH, E., AIMÈ, E., MAIRESSE, G. H., GUÉNON, C. & SBRAGIA, P. 2012b. Optimizing Pacemaker Longevity with Pacing Mode and Settings Programming: Results from a Pacemaker Multicenter Registry. Pacing and Clinical Electrophysiology, 35, 403-408. BERGER, T., ROITHINGER, F. X., ANTRETTER, H., HANGLER, H., PACHINGER, O. & HINTRINGER, F. 2003. The influence of high versus normal impedance ventricular leads on pacemaker generator longevity. Pacing Clin Electrophysiol, 26, 2116-20. BERNSTEIN, A. D., IRWIN, M. E., PARSONNET, V., WILKOFF, B. L., BLACK, W. R., BUCKINGHAM, T. A., MALONEY, J. D., REYNOLDS, D. D., SAKSENA, S. & SINGER, I. 1994. Report of the NASPE Policy Conference on Antibradycardia Pacemaker Follow‐Up: Effectiveness, Needs, and Resources. Pacing and Clinical Electrophysiology, 17, 1714-1729. BETOCCHI, S., PISCIONE, F., VILLARI, B., PACE, L., CIARMIELLO, A., PERRONE-FILARDI, P., SALVATORE, C., SALVATORE, M. & CHIARIELLO, M. 1993. Effects of induced asynchrony on left ventricular diastolic function in patients with coronary artery disease. Journal of the American College of Cardiology, 21, 1124-1131. BHRS 2015. British Heart Rhythm Society Clinical Guidance for the Follow-up of Cardiac Implantable Electronic Devices for Cardiac Rhythm Management. BHRS 2020. Clinical Standards And Guidelines For The Follow-up of Cardiac Implantable Electronic Devices (CIEDs) for Cardiac Rhythm Management BHRS Clinical Standards. Avalable Online. BLANC, J. & INVESTIGATORS, B. T. Biventricular pacing for atrio-ventricular block to prevent cardiac desynchronization. Results presented at European Society of Cardiology Congress, Barcelona, Spain, 2014. BORIANI, G., RUSCONI, L., BIFFI, M., PAVIA, L., SASSARA, M., MALFITANO, D., BONGIORNI, M. G., PADELETTI, L., FILICE, I. & SANFELICI, D. 2006. Role of ventricular autocapture function in increasing longevity of DDDR pacemakers: a prospective study. Europace, 8, 216-220. BOSSUYT, P. M., REITSMA, J. B., BRUNS, D. E., GATSONIS, C. A., GLASZIOU, P. P., IRWIG, L., LIJMER, J. G., MOHER, D., RENNIE, D., DE VET, H. C., KRESSEL, H. Y., RIFAI, N., GOLUB, R. M., ALTMAN, D. G., HOOFT, L., KOREVAAR, D. A., COHEN, J. F. & GROUP, S. 2015. STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies. Clin Chem, 61, 1446-52. BRADSHAW, P. J., STOBIE, P., KNUIMAN, M. W., BRIFFA, T. G. & HOBBS, M. S. 2014a. Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population. Open heart, 1, e000177. BRADSHAW, P. J., STOBIE, P., KNUIMAN, M. W., BRIFFA, T. G. & HOBBS, M. S. T. 2014b. Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population. Open Heart, 1, e000177. BRECKER, S. J., XIAO, H., SPARROW, J. & GIBSON, D. 1992. Effects of dual-chamber pacing with short atrioventricular delay in dilated cardiomyopathy. The Lancet, 340, 1308-1312. BREIVIK, K., OHM, O. J. & SEGADAL, L. 1979. Sick sinus syndrome treated with permanent pacemaker in 109 patients: a follow‐up study. Acta medica Scandinavica, 206, 153-159. BRIGNOLE, M., AURICCHIO, A., BARON-ESQUIVIAS, G., BORDACHAR, P., BORIANI, G., BREITHARDT, O., CLELAND, J., DEHARO, J., DELGADO, V. & ELLIOTT, P. 2013a. Document Reviewers. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J, 34, 2281-2329. BRIGNOLE, M., AURICCHIO, A., BARON-ESQUIVIAS, G., BORDACHAR, P., BORIANI, G., BREITHARDT, O.-A., CLELAND, J., DEHARO, J.-C. & DELGADO, V. 2013b. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). European heart journal, 34, 2281-2329. BRUNNER, M., OLSCHEWSKI, M., GEIBEL, A., BODE, C. & ZEHENDER, M. 2004. Long-term survival after pacemaker implantation: Prognostic importance of gender and baseline patient characteristics. European Heart Journal, 25, 88-95. BURRI, H., SUNTHORN, H., DORSAZ, P. A. & SHAH, D. 2005. Prospective study of axillary vein puncture with or without contrast venography for pacemaker and defibrillator lead implantation. Pacing and clinical electrophysiology, 28, S280-S283. CAPUCCI, A., BORIANI, G., SPECCHIA, S., MARINELLI, M., SANTARELLI, A. & MAGNANI, B. 1992. Evaluation by cardiopulmonary exercise test of DDDR versus DDD pacing. Pacing and Clinical Electrophysiology, 15, 1908-1913. CARLSON, M. D., IP, J., MESSENGER, J., BEAU, S., KALBFLEISCH, S., GERVAIS, P., CAMERON, D. A., DURAN, A., VAL-MEJIAS, J. & MACKALL, J. 2003. A new pacemaker algorithm for the treatment of atrial fibrillation: results of the Atrial Dynamic Overdrive Pacing Trial (ADOPT). Journal of the American College of Cardiology, 42, 627-633. CARMOUCHE, D. G., BUBIEN, R. S. & KAY, G. N. 1998. The effect of maximum heart rate on oxygen kinetics and exercise performance at low and high workloads. Pacing and clinical electrophysiology, 21, 679-686. CARROZ, P., DELAY, D. & GIROD, G. 2010. Pseudo-pacemaker syndrome in a young woman with first-degree atrio-ventricular block. Europace, 12, 594-596. CASTELNUOVO, E., STEIN, K., PITT, M., GARSIDE, R. & PAYNE, E. 2005. The effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber pacemakers for bradycardia due to atrioventricular block or sick sinus syndrome: systematic review and economic evaluation. NIHR Health Technology Assessment programme: Executive Summaries. NIHR Journals Library. CHATTERJEE, S., BIONDI-ZOCCAI, G., ABBATE, A., D’ASCENZO, F., CASTAGNO, D., VAN TASSELL, B., MUKHERJEE, D. & LICHSTEIN, E. 2013. Benefits of β blockers in patients with heart failure and reduced ejection fraction: network meta-analysis. Bmj, 346, f55. CHENG, A., CALKINS, H. & BERGER, R. D. 2009a. Managed ventricular pacing below the lower rate limit: is it simply caused by ventricular-based pacing? Heart rhythm, 6, 1240-1241. CHENG, S., KEYES, M. J., LARSON, M. G., MCCABE, E. L., NEWTON-CHEH, C., LEVY, D., BENJAMIN, E. J., VASAN, R. S. & WANG, T. J. 2009b. Long-term outcomes in individuals with prolonged PR interval or first-degree atrioventricular block. Jama, 301, 2571-2577. CHOW, G. V., MARINE, J. E. & FLEG, J. L. 2012. Epidemiology of arrhythmias and conduction disorders in older adults. Clinics in geriatric medicine, 28, 539-553. COLLINS, G. S., REITSMA, J. B., ALTMAN, D. G. & MOONS, K. G. 2015. Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD): the TRIPOD Statement. Br J Surg, 102, 148-58. CONNOLLY, S. J., KERR, C. R., GENT, M., ROBERTS, R. S., YUSUF, S., GILLIS, A. M., SAMI, M. H., TALAJIC, M., TANG, A. S. & KLEIN, G. J. 2000. Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. New England Journal of Medicine, 342, 1385-1391. CROSSLEY, G. H., GAYLE, D. D., SIMMONS, T. W., HAISTY, W. K., BAILEY, J. R., DAVIS-O'BRIEN, K., HAMMON, J. W. & FITZGERALD, D. M. 1996. Reprogramming pacemakers enhances longevity and is cost-effective. Circulation, 94, II245-7. CUBBON, R. M., GALE, C. P., KEARNEY, L. C., SCHECHTER, C. B., BROOKSBY, W. P., NOLAN, J., FOX, K. A., RAJWANI, A., BAIG, W. & GROVES, D. 2011. Changing characteristics and mode of death associated with chronic heart failure caused by left ventricular systolic dysfunction: a study across therapeutic eras. Circulation: Heart Failure, 4, 396-403. CURTIS, A. B., ADAMSON, P. B., CHUNG, E., JOHN SUTTON, M. S., TANG, F. & WORLEY, S. 2007. Biventricular versus right ventricular pacing in patients with AV block (BLOCK HF): clinical study design and rationale. Journal of cardiovascular electrophysiology, 18, 965-971. CURTIS, A. B., WORLEY, S. J., ADAMSON, P. B., CHUNG, E. S., NIAZI, I., SHERFESEE, L., SHINN, T. & ST JOHN SUTTON, M. 2013. Biventricular pacing for atrioventricular block and systolic dysfunction. N Engl J Med, 368, 1585-1593. CVIJIC, M., DUCHENNE, J., ÜNLÜ, S., MICHALSKI, B., AARONES, M., WINTER, S., AAKHUS, S., FEHSKE, W., STANKOVIC, I. & VOIGT, J.-U. 2017. Timing of myocardial shortening determines left ventricular regional myocardial work and regional remodelling in hearts with conduction delays. European Heart Journal-Cardiovascular Imaging, 19, 941-949. DA COSTA, A., GABRIEL, L., ROMEYER-BOUCHARD, C., GÉRALDINE, B., GATE-MARTINET, A., LAURENCE, B., LEVALLOIS, M. & ISAAZ, K. 2013. Focus on right ventricular outflow tract septal pacing. Archives of cardiovascular diseases, 106, 394-403. DALEN, H., THORSTENSEN, A., AASE, S. A., INGUL, C. B., TORP, H., VATTEN, L. J. & STOYLEN, A. 2009. Segmental and global longitudinal strain and strain rate based on echocardiography of 1266 healthy individuals: the HUNT study in Norway. European Journal of Echocardiography, 11, 176-183. DAVY, J., HOFFMANN, E., FREY, A., JOCHAM, K., ROSSI, S., DUPUIS, J., FRABETTI, L., DUCLOUX, P., PRADES, E. & JAUVERT, G. 2012. Near elimination of ventricular pacing in SafeR mode compared to DDD modes: a randomized study of 422 patients. Pacing and clinical electrophysiology, 35, 392-402. DE VRIES, L., LEENING, M., DIJK, W., HOOIJSCHUUR, C., STRICKER, B. & VAN HEMEL, N. 2017. Trends in service time of pacemakers in the Netherlands: a long-term nationwide follow-up study. Netherlands Heart Journal, 25, 581-591. DEAN, J. & SULKE, N. 2016. Pacemaker battery scandal. British Medical Journal Publishing Group. DEHARO, J. & DJIANE, P. Pacemaker longevity. Replacement of the device. Annales de cardiologie et d'angéiologie, 2005. 26-31. DONOSO, E., ADLER, L. N. & FRIEDBERG, C. K. 1964. Unusual forms of second-degree atrioventricular block, including mobitz type-II block, associated with the Morgagni-Adams-Stokes Syndrome. American heart journal, 67, 150-157. DOROSZ, J. L., LEZOTTE, D. C., WEITZENKAMP, D. A., ALLEN, L. A. & SALCEDO, E. E. 2012. Performance of 3-dimensional echocardiography in measuring left ventricular volumes and ejection fraction: a systematic review and meta-analysis. Journal of the American College of Cardiology, 59, 1799-1808. DUCHENNE, J., TURCO, A., ÜNLÜ, S., PAGOURELIAS, E. D., VUNCKX, K., DEGTIAROVA, G., BÉZY, S., CVIJIC, M., NUYTS, J. & CLAUS, P. 2019. Left ventricular remodeling results in homogenization of myocardial work distribution. Circulation: Arrhythmia and Electrophysiology, 12, e007224. EDHAG, O. 1969. Long-term cardiac pacing. Experience of fixed-rate pacing with an endocardial electrode in 260 patients. Acta medica Scandinavica. Supplementum, 502, 9. ELDRIDGE, S. M., CHAN, C. L., CAMPBELL, M. J., BOND, C. M., HOPEWELL, S., THABANE, L. & LANCASTER, G. A. 2016. CONSORT 2010 statement: extension to randomised pilot and feasibility trials. Pilot and feasibility studies, 2, 64. ELLENBOGEN, K. A., WILKOFF, B. L., KAY, G. N., LAU, C. P. & AURICCHIO, A. 2016. Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy E-Book, Elsevier Health Sciences. EPSTEIN, A. E., DIMARCO, J. P., ELLENBOGEN, K. A., ESTES, N. A., 3RD, FREEDMAN, R. A., GETTES, L. S., GILLINOV, A. M., GREGORATOS, G., HAMMILL, S. C., HAYES, D. L., HLATKY, M. A., NEWBY, L. K., PAGE, R. L., SCHOENFELD, M. H., SILKA, M. J., STEVENSON, L. W., SWEENEY, M. O., AMERICAN COLLEGE OF CARDIOLOGY, F., AMERICAN HEART ASSOCIATION TASK FORCE ON PRACTICE, G. & HEART RHYTHM, S. 2013. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. Circulation, 127, e283-352. ESCHALIER, R., PLOUX, S., RITTER, P., HAÏSSAGUERRE, M., ELLENBOGEN, K. A. & BORDACHAR, P. 2015. Nonspecific intraventricular conduction delay: definitions, prognosis, and implications for cardiac resynchronization therapy. Heart Rhythm, 12, 1071-1079. FELD, G. K. 2014. AV Delay Optimization vs. Intrinsic Conduction in Pacemaker Patients With Long PR Intervals (AV Delay). ClinialTrials.gov. FERGUSON JR, T. B., FERGUSON, C. L., CRITES, K. & CRIMMINS-REDA, P. 1996. The additional hospital costs generated in the management of complications of pacemaker and defibrillator implantations. The Journal of thoracic and cardiovascular surgery, 111, 742-752. FOLEY, P. W., LEYVA, F. & FRENNEAUX, M. P. 2009. What is treatment success in cardiac resynchronization therapy? Europace, 11, v58-v65. FRASER, J. D., GILLIS, A. M., IRWIN, M. E., NISHIMURA, S., TYERS, G. & PHILIPPON, F. 2000. Guidelines for pacemaker follow-up in Canada: a consensus statement of the Canadian Working Group on Cardiac Pacing. The Canadian journal of cardiology, 16, 355-63, 367-76. FREUDENBERGER, R., AARON, M., KRUEGER, S., LABEAU, M., KLECKNER, K. & KLEPFER, R. N. 2008. Acute electromechanical effects of atrioventricular coupled pacing in patients with heart failure. Journal of cardiac failure, 14, 35-40. FRIEDBERG, C. K., DONOSO, E. & STEIN, W. 1964. Nonsurgical acquired heart block. Annals of the New York Academy of Sciences, 111, 835-847. GADLER, F., VALZANIA, C. & LINDE, C. 2014. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry. Ep Europace, 17, 69-77. GARIN, O., HERDMAN, M., VILAGUT, G., FERRER, M., RIBERA, A., RAJMIL, L., VALDERAS, J. M., GUILLEMIN, F., REVICKI, D. & ALONSO, J. 2014. Assessing health-related quality of life in patients with heart failure: a systematic, standardized comparison of available measures. Heart failure reviews, 19, 359-367. GERLAND, P., RAFTERY, A. E., ŠEVČÍKOVÁ, H., LI, N., GU, D., SPOORENBERG, T., ALKEMA, L., FOSDICK, B. K., CHUNN, J. & LALIC, N. 2014. World population stabilization unlikely this century. Science, 346, 234-237. GIERULA, J., CUBBON, R. M., JAMIL, H. A., BYROM, R., BAXTER, P. D., PAVITT, S., GILTHORPE, M. S., HEWISON, J., KEARNEY, M. T. & WITTE, K. K. 2013. Cardiac resynchronization therapy in pacemaker-dependent patients with left ventricular dysfunction. Europace, 15, 1609-1614. GIERULA, J., CUBBON, R. M., JAMIL, H. A., BYROM, R. J., WALDRON, Z. L., PAVITT, S., KEARNEY, M. T. & WITTE, K. K. 2015. Patients with long-term permanent pacemakers have a high prevalence of left ventricular dysfunction. Journal of Cardiovascular Medicine, 16, 743-750. GIERULA, J., JAMIL, H. A., BYROM, R., JOY, E. R., CUBBON, R. M., KEARNEY, M. T. & WITTE, K. K. 2014. Pacing-associated left ventricular dysfunction? Think reprogramming first! Heart, 100, 765-769. GILLIS, A. M. 2006. Redefining physiologic pacing: lessons learned from recent clinical trials. Heart Rhythm, 3, 1367-72. GILLIS, A. M., PÜRERFELLNER, H., ISRAEL, C. W., SUNTHORN, H., KACET, S., ANELLI‐MONTI, M., TANG, F., YOUNG, M., BORIANI, G. & INVESTIGATORS, M. E. C. S. 2006. Reducing unnecessary right ventricular pacing with the managed ventricular pacing mode in patients with sinus node disease and AV block. Pacing and clinical electrophysiology, 29, 697-705. GLICK, H., COOK, J., KINOSIAN, B., PITT, B., BOURASSA, M. G., POULEUR, H. & GERTH, W. 1995. Costs and effects of enalapril therapy in patients with symptomatic heart failure: an economic analysis of the Studies of Left Ventricular Dysfunction (SOLVD) Treatment Trial. Journal of cardiac failure, 1, 371-380. GOLDBERGER, J. J., JOHNSON, N. P. & GIDEA, C. 2011. Significance of asymptomatic bradycardia for subsequent pacemaker implantation and mortality in patients> 60 years of age. The American journal of cardiology, 108, 857-861. GOLDSTEIN, D. J., LOSQUADRO, W. & SPOTNITZ, H. M. 1998. Outpatient pacemaker procedures in orally anticoagulated patients. Pacing and clinical electrophysiology, 21, 1730-1734. H., B. 2014. Pacemakers longevity: Do we get what it is promised? . Journal of Interventional Cardiac Electrophysiology 1. HAGHJOO, M. 2017. Cardiac implantable electronic devices, Elsevier Health Sciences. HALL, N. 2015. Ohms Law [Online]. National Aeronautics and Space Administration. Available: https://www.grc.nasa.gov/www/k-12/airplane/ohms.html [Accessed 01/03/2020 2020]. HALPERIN, J. L., LEVINE, G. N., AL-KHATIB, S. M., BIRTCHER, K. K., BOZKURT, B., BRINDIS, R. G., CIGARROA, J. E., CURTIS, L. H., FLEISHER, L. A. & GENTILE, F. 2016. Further evolution of the ACC/AHA clinical practice guideline recommendation classification system: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation, 133, 1426-1428. HARKNESS, A., RING, L., AUGUSTINE, D. X., OXBOROUGH, D., ROBINSON, S. & SHARMA, V. 2020. Normal reference intervals for cardiac dimensions and function for use in echocardiographic practice: a guideline from the British Society of Echocardiography. Echo research and practice, 7, G1-G18. HAUSER, R. G., KALLINEN, L. M., ALMQUIST, A. K., GORNICK, C. C. & KATSIYIANNIS, W. T. 2007. Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead. Heart Rhythm, 4, 892-896. HAYES, D. L., NACCARELLI, G. V., FURMAN, S., PARSONNET, V., REYNOLDS, D., GOLDSCHLAGER, N., GILLETTE, P., MALONEY, J. D., SAXON, L. & LEON, A. 2003. NASPE training requirements for cardiac implantable electronic devices: selection, implantation, and follow‐up. Pacing and clinical electrophysiology, 26, 1556-1562. HAYES, J. J., SHARMA, A. D., LOVE, J. C., HERRE, J. M., LEONEN, A. O., KUDENCHUK, P. J. & INVESTIGATORS, D. 2006. Abnormal conduction increases risk of adverse outcomes from right ventricular pacing. Journal of the American College of Cardiology, 48, 1628-1633. HAYWOOD, G. A., JONES, S. M., CAMM, A. J. & WARD, D. E. 1991. Day case permanent pacing. Pacing and Clinical Electrophysiology, 14, 773-777. HAYWOOD, G. A., KATRITSIS, D., WARD, J., LEIGH-JONES, M., WARD, D. E. & CAMM, A. J. 1993. Atrial adaptive rate pacing in sick sinus syndrome: effects on exercise capacity and arrhythmias. Heart, 69, 174-178. HEALEY, J., TOFF, W., LAMAS, G. & A, A. H., THORPE KE, ELLENBOGEN K A, ET AL. 2006. Cardiovascular outcomes with atrial-based pacing compared with ventricular pacing: meta-analysis of randomized trials, using individual patient data. Circulation [Internet], 114, 11-7. HEIDBÜCHEL, H., LIOEN, P., FOULON, S., HUYBRECHTS, W., ECTOR, J., WILLEMS, R. & ECTOR, H. 2008. Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator. Europace, 10, 351-357. HEIMDAL, A., STØYLEN, A., TORP, H. & SKJÆRPE, T. 1998. Real-time strain rate imaging of the left ventricle by ultrasound. Journal of the American Society of Echocardiography, 11, 1013-1019. HEYNDRICKX, G., VILAINE, J.-P., KNIGHT, D. & VATNER, S. 1985a. Effects of altered site of electrical activation on myocardial performance during inotropic stimulation. Circulation, 71, 1010-1016. HEYNDRICKX, G. R., VILAINE, J., KNIGHT, D. & VATNER, S. F. 1985b. Effects of altered site of electrical activation on myocardial performance during inotropic stimulation. Circulation, 71, 1010-1016. HOGG, K., SWEDBERG, K. & MCMURRAY, J. 2004. Heart failure with preserved left ventricular systolic function: epidemiology, clinical characteristics, and prognosis. Journal of the American College of Cardiology, 43, 317-327. HOLMQVIST, F., HELLKAMP, A. S., LEE, K. L., LAMAS, G. A. & DAUBERT, J. P. 2014. Adverse Effects of First‐Degree AV‐Block in Patients with Sinus Node Dysfunction: Data from the Mode Selection Trial. Pacing and Clinical Electrophysiology, 37, 1111-1119. HONG, W.-J., YUNG, T.-C., LUN, K.-S., WONG, S. J. & CHEUNG, Y.-F. 2009. Impact of right ventricular pacing on three-dimensional global left ventricular dyssynchrony in children and young adults with congenital and acquired heart block associated with congenital heart disease. American Journal of Cardiology, 104, 700-706. HUSSAIN, M. A., FURUYA‐KANAMORI, L., KAYE, G., CLARK, J. & DOI, S. A. 2015. The effect of right ventricular apical and nonapical pacing on the short‐and long‐term changes in left ventricular ejection fraction: A systematic review and meta‐analysis of randomized‐controlled trials. Pacing and Clinical Electrophysiology, 38, 1121-1136. IGLESIAS, J., BENEZET MAZUECOS, J., CORTES, M., RUBIO, J., DE LA CRUZ, E., DE LA VIEJA, J., CALLE, S., QUINONES, M., SANCHEZ-BORQUE, P. & FARRE, J. Abnormalities in AutoCapture pacemaker algorithm in atrial fibrillation patients compromise battery longevity. EUROPEAN HEART JOURNAL, 2014. OXFORD UNIV PRESS GREAT CLARENDON ST, OXFORD OX2 6DP, ENGLAND, 103-104. IORGULESCU, C., RADU, D., CONSTANTINESCU, D., CALDARARU, C. & DOROBANTU, M. 2014. Right ventricular septal pacing-clinical and electrical predictors for LV contraction asynchrony. Journal of medicine and life, 7, 83-89. IRNICH, W. 1975. Engineering concepts of pacemaker electrodes. Engineering in Medicine. Springer. J MORENO PLANAS, M. S., S BOVEDA, P MABO, F BODE, J RODRIGUEZ GARCIA, G CARRERAS, D BUKART-KUTTNER, A ROUSSEAU-PLASSE ), P DEFAYE Pacemaker longevity in patients implanted for sinus node disease or atrio-ventricular block: a post-hoc analysis of the ANSWER study. European Heart rythm Association, 2015. P584. JAHANGIR, A., SHEN, W.-K., NEUBAUER, S. A., BALLARD, D. J., HAMMILL, S. C., HODGE, D. O., LOHSE, C. M., GERSH, B. J. & HAYES, D. L. 1999. Relation between mode of pacing and long-term survival in the very elderly. Journal of the American College of Cardiology, 33, 1208-1216. JAMIL, H. A., GIERULA, J., PATON, M. F., BYROM, R., LOWRY, J. E., CUBBON, R. M., CAIRNS, D. A., KEARNEY, M. T. & WITTE, K. K. 2016. Chronotropic incompetence does not limit exercise capacity in chronic heart failure. Journal of the American College of Cardiology, 67, 1885-1896. JELIĆ, V., BELKIĆ, K., DJORDJEVIĆ, M. & KOCOVIĆ, D. 1992. Survival in 1,431 pacemaker patients: prognostic factors and comparison with the general population. Pacing and Clinical Electrophysiology, 15, 141-147. JIANG, Z., CONNOLLY, A. & MANGHARAM, R. Using the virtual heart model to validate the mode-switch pacemaker operation. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 2010. IEEE, 6690-6693. JOHANSSON, B. W. 1966. Complete heart block. A clinical, hemodynamic and pharmacological study in patients with and without an artificial pacemaker. Acta medica Scandinavica. Supplementum, 451, 1. JONES, S., CARLEY, S. & HARRISON, M. 2003. An introduction to power and sample size estimation. Emergency medicine journal: EMJ, 20, 453. KAMALVAND, K., TAN, K., KOTSAKIS, A., BUCKNALL, C. & SULKE, N. 1997. Is mode switching beneficial? A randomized study in patients with paroxysmal atrial tachyarrhythmias. Journal of the American College of Cardiology, 30, 496-504. KAYE, G. C., LINKER, N. J., MARWICK, T. H., POLLOCK, L., GRAHAM, L., POULIOT, E., POLONIECKI, J., GAMMAGE, M., INVESTIGATORS, P.-P. T. & KAYE, G. 2014. Effect of right ventricular pacing lead site on left ventricular function in patients with high-grade atrioventricular block: results of the Protect-Pace study. European heart journal, 36, 856-862. KENNY, T. 2005. The nuts and bolts of cardiac pacing, Wiley Online Library. KIEHL, E. L., MAKKI, T., MATAR, R. M., JOHNSTON, D. R., RICKARD, J. W., TARAKJI, K. G., KANJ, M., WAZNI, O. M., SALIBA, W. I. & VARMA, N. 2017. Incidence and predictors of late atrioventricular conduction recovery among patients requiring permanent pacemaker for complete heart block after cardiac surgery. Heart Rhythm, 14, 1786-1792. KIM, S.-H., OH, Y.-S., NAM, G.-B., CHOI, K.-J., PARK, J. S., PARK, S. W., PARK, S.-J., ON, Y. K., KIM, J. S. & SHIN, W.-S. 2014. Paced QRS axis as a predictor of pacing-induced left ventricular dysfunction. Journal of Interventional Cardiac Electrophysiology, 41, 223-229. KINDERMANN, M., SCHWAAB, B., BERG, M. & FRÖHLIG, G. 2001. Longevity of dual chamber pacemakers: device and patient related determinants. Pacing and clinical electrophysiology, 24, 810-815. KONSTAM, M. A., UDELSON, J. E., ANAND, I. S. & COHN, J. N. 2003. Ventricular remodeling in heart failure: a credible surrogate endpoint. Journal of cardiac failure, 9, 350-353. KOU, S., CABALLERO, L., DULGHERU, R., VOILLIOT, D., DE SOUSA, C., KACHARAVA, G., ATHANASSOPOULOS, G. D., BARONE, D., BARONI, M. & CARDIM, N. 2014. Echocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study. European Heart Journal–Cardiovascular Imaging, 15, 680-690. KRAMER, D. G., TRIKALINOS, T. A., KENT, D. M., ANTONOPOULOS, G. V., KONSTAM, M. A. & UDELSON, J. E. 2010. Quantitative Evaluation of Drug or Device Effects on Ventricular Remodeling as Predictors of Therapeutic Effects on Mortality in Patients With Heart Failure and Reduced Ejection Fraction: A Meta-Analytic Approach. Journal of the American College of Cardiology, 56, 392-406. KRONBORG, M. B., MORTENSEN, P. T., GERDES, J. C., JENSEN, H. K. & NIELSEN, J. C. 2011. His and para-His pacing in AV block: feasibility and electrocardiographic findings. Journal of interventional cardiac electrophysiology, 31, 255. KROON, W., LUMENS, J., POTSE, M., SUERDER, D., KLERSY, C., REGOLI, F., MURZILLI, R., MOCCETTI, T., DELHAAS, T. & KRAUSE, R. 2015. In vivo electromechanical assessment of heart failure patients with prolonged QRS duration. Heart Rhythm, 12, 1259-1267. KUMAR, V., YAMADA, T. & DOPPALAPUDI, H. 2016. Discordance between Auto Mode Switch (AMS) Episodes and Atrial Tachyarrhythmia (AT/AF) Burden. Pacing and Clinical Electrophysiology, 39, 398-400. KUSUMOTO, F. M., SCHOENFELD, M. H., BARRETT, C., EDGERTON, J. R., ELLENBOGEN, K. A., GOLD, M. R., GOLDSCHLAGER, N. F., HAMILTON, R. M., JOGLAR, J. A. & KIM, R. J. 2019. 2018 ACC/AHA/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines, and the Heart Rhythm Society. Circulation, 140, e333-e381. KUTYIFA, V., STOCKBURGER, M., DAUBERT, J. P., HOLMQVIST, F., OLSHANSKY, B., SCHUGER, C., KLEIN, H., GOLDENBERG, I., BRENYO, A. & MCNITT, S. 2014. PR Interval Identifies Clinical Response in Patients With Non–Left Bundle Branch BlockCLINICAL PERSPECTIVE: A Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy Substudy. Circulation: Arrhythmia and Electrophysiology, 7, 645-651. LAMAS, G., LEE, K., SWEENEY, M., SILVERMAN, R., LEON, A., YEE, R., MARINCHAK, R., FLAKER, G., SCHRON, E. & ORAV, E. 2002. Mode Selection Trial in Sinus-Node Dysfunction. Ventricular pacing or dual-chamber pacing for sinus-node dysfunction. N Engl J Med, 346, 1854-1862. LAMAS, G. A., ORAV, E. J., STAMBLER, B. S., ELLENBOGEN, K. A., SGARBOSSA, E. B., HUANG, S. K. S., MARINCHAK, R. A., ESTES, N. M., MITCHELL, G. F. & LIEBERMAN, E. H. 1998. Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing. New England Journal of Medicine, 338, 1097-1104. LANG, R. M., BADANO, L. P., MOR-AVI, V., AFILALO, J., ARMSTRONG, A., ERNANDE, L., FLACHSKAMPF, F. A., FOSTER, E., GOLDSTEIN, S. A. & KUZNETSOVA, T. 2015. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. European Heart Journal-Cardiovascular Imaging, 16, 233-271. LAU, C. P., RUSHBY, J., LEIGH‐JONES, M., TAM, C., POLONIECKI, J., INGRAM, A., SUTTON, R. & CAMM, A. 1989. Symptomatology and quality of life in patients with rate‐responsive pacemakers: A double‐blind, randomized, crossover study. Clinical cardiology, 12, 505-512. LAU, E. W. 2007. Upper body venous access for transvenous lead placement—review of existent techniques. Pacing and clinical electrophysiology, 30, 901-909. LAU, E. W. 2017. Technologies for prolonging cardiac implantable electronic device longevity. Pacing and Clinical Electrophysiology, 40, 75-96. LEE, M. A., DAE, M. W., LANGBERG, J. J., GRIFFIN, J. C., CHIN, M. C., FINKBEINER, W. E., O'CONNELL, J. W., BOTVINICK, E., SCHEINMAN, M. M. & ROSENQVIST, M. 1994. Effects of long-term right ventricular apical pacing on left ventricular perfusion, innervation, function and histology. Journal of the American College of Cardiology, 24, 225-232. LEITMAN, M., LYSYANSKY, P., SIDENKO, S., SHIR, V., PELEG, E., BINENBAUM, M., KALUSKI, E., KRAKOVER, R. & VERED, Z. 2004. Two-dimensional strain–a novel software for real-time quantitative echocardiographic assessment of myocardial function. Journal of the American Society of Echocardiography, 17, 1021-1029. LEUNG, S.-K. & LAU, C.-P. 2000. Developments in sensor-driven pacing. Cardiology clinics, 18, 113-155. LIEBERMAN, R., PADELETTI, L., SCHREUDER, J., JACKSON, K., MICHELUCCI, A., COLELLA, A., EASTMAN, W., VALSECCHI, S. & HETTRICK, D. A. 2006. Ventricular pacing lead location alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction. J Am Coll Cardiol, 48, 1634-41. LINDEMANS, F. W. & DENIER VAN DER GON, J. J. 1978. Current thresholds and liminal size in excitation of heart muscle. Cardiovascular research, 12, 477-485. MAFI-RAD, M., LUERMANS, J. G., BLAAUW, Y., JANSSEN, M., CRIJNS, H. J., PRINZEN, F. W. & VERNOOY, K. 2016. Feasibility and acute hemodynamic effect of left ventricular septal pacing by transvenous approach through the interventricular septum. Circulation: Arrhythmia and Electrophysiology, 9, e003344. MALLELA, V. S., ILANKUMARAN, V. & RAO, N. S. 2004. Trends in cardiac pacemaker batteries. Indian pacing and electrophysiology journal, 4, 201. MANOLIS, A. S. & MELITA, H. 2017. Prevention of cardiac implantable electronic device infections: single operator technique with use of povidone‐iodine, double gloving, meticulous aseptic/antiseptic measures and antibiotic prophylaxis. Pacing and Clinical Electrophysiology, 40, 26-34. MANSOUR, F. & KHAIRY, P. 2012. Electrical storm due to managed ventricular pacing. Heart Rhythm, 9, 842-843. MARTENS, P., DEFERM, S., BERTRAND, P. B., VERBRUGGE, F. H., RAMAEKERS, J., VERHAERT, D., DUPONT, M., VANDERVOORT, P. M. & MULLENS, W. 2020. The detrimental effect of RA pacing on LA function and clinical outcome in cardiac resynchronization therapy. JACC: Cardiovascular Imaging, 13, 895-906. MARTENS, P., NUYENS, D., RIVERO-AYERZA, M., VAN HERENDAEL, H., VERCAMMEN, J., CEYSSENS, W., LUWEL, E., DUPONT, M. & MULLENS, W. 2019. Sacubitril/valsartan reduces ventricular arrhythmias in parallel with left ventricular reverse remodeling in heart failure with reduced ejection fraction. Clinical Research in Cardiology, 108, 1074-1082. MARTINELLI, F. M., DE SIQUEIRA, S., COSTA, R., GRECO, O., MOREIRA, L., D'AVILA, A. & HEIST, E. 2010. Conventional versus biventricular pacing in heart failure and bradyarrhythmia: the COMBAT study. Journal of cardiac failure, 16, 293. MARWICK, T. H. 2006. Measurement of strain and strain rate by echocardiography: ready for prime time? Journal of the American College of Cardiology, 47, 1313-1327. MAYOSI, B. M., LITTLE, F. & MILLAR, R. N. S. 1999. Long‐term survival after permanent pacemaker implantation in young adults: 30 year experience. Pacing and clinical electrophysiology, 22, 407-412. MCMANUS, D. D., SHAH, S. J., FABI, M. R., ROSEN, A., WHOOLEY, M. A. & SCHILLER, N. B. 2009. Prognostic value of left ventricular end-systolic volume index as a predictor of heart failure hospitalization in stable coronary artery disease: data from the Heart and Soul Study. Journal of the American Society of Echocardiography, 22, 190-197. MCMEEKIN, J. D., LAUTNER, D., HANSON, S. & GULAMHUSEIN, S. S. 1990. Importance of heart rate response during exercise in patients using atrioventricular synchronous and ventricular pacemakers. Pacing and Clinical Electrophysiology, 13, 59-68. MCMURRAY, J. J., PACKER, M., DESAI, A. S., GONG, J., LEFKOWITZ, M. P., RIZKALA, A. R., ROULEAU, J., SHI, V. C., SOLOMON, S. D. & SWEDBERG, K. 2013. Dual angiotensin receptor and neprilysin inhibition as an alternative to angiotensin‐converting enzyme inhibition in patients with chronic systolic heart failure: rationale for and design of the Prospective comparison of ARNI with ACEI to Determine Impact on Global Mortality and morbidity in Heart Failure trial (PARADIGM‐HF). European journal of heart failure, 15, 1062-1073. MEDTRONIC. 2020. Our Pacemakers for Bradycardia. [Online]. Available: https://www.medtronic.com/us-en/patients/treatments-therapies/pacemakers/our.html. [Accessed 01/03/2020 2020]. MIGNOT, A., DONAL, E., ZAROUI, A., REANT, P., SALEM, A., HAMON, C., MONZY, S., ROUDAUT, R., HABIB, G. & LAFITTE, S. 2010. Global longitudinal strain as a major predictor of cardiac events in patients with depressed left ventricular function: a multicenter study. Journal of the American Society of Echocardiography, 23, 1019-1024. MOND, H. G. 1999. Recent advances in pacemaker lead technology. Cardiac Electrophysiology Review, 3, 5-9. MOND, H. G. 2001. The world survey of cardiac pacing and cardioverter defibrillators: Calendar year 1997‐Asian Pacific, Middle East, South America, and Canada. Pacing and Clinical Electrophysiology, 24, 856-862. MOND, H. G. & PROCLEMER, A. 2011a. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009--a World Society of Arrhythmia's project. Pacing Clin Electrophysiol, 34, 1013-27. MOND, H. G. & PROCLEMER, A. 2011b. The 11th world survey of cardiac pacing and implantable cardioverter‐defibrillators: calendar year 2009–a World Society of Arrhythmia's project. Pacing and clinical electrophysiology, 34, 1013-1027. MORGAN, K., MCGEE, H. & SHELLEY, E. 2007. Quality of life assessment in heart failure interventions: a 10-year (1996–2005) review. European Journal of Cardiovascular Prevention & Rehabilitation, 14, 589-607. MORRIS‐THURGOOD, J., CHIANG, C. M., ROGHELLE, J., STEINHAUS, B., ILSLEY, C. & PAUL, V. 1994. A rate responsive pacemaker that physiologically reduces pacing rates at rest. Pacing and Clinical Electrophysiology, 17, 1928-1932. MULPURU, S. K., MADHAVAN, M., MCLEOD, C. J., CHA, Y.-M. & FRIEDMAN, P. A. 2017. Cardiac pacemakers: function, troubleshooting, and management: part 1 of a 2-part series. Journal of the American College of Cardiology, 69, 189-210. MURGATROYD, F. D., HELMLING, E., LEMKE, B., EBER, B., MEWIS, C., VAN DER MEER-HENSGENS, J., CHANG, Y., KHALAMEIZER, V. & KATZ, A. 2010. Manual vs. automatic capture management in implantable cardioverter defibrillators and cardiac resynchronization therapy defibrillators. Europace, 12, 811-6. NAGY, K. V., SZÉPLAKI, G., BOROS, A. M., PERGE, P., APOR, A., KOSZTIN, A., MOLNÁR, L., GELLÉR, L. & MERKELY, B. 2017. QUALITY OF LIFE MEASURED WITH EUROQOL-5D QUESTIONNAIRE PREDICTS LONG TERM MORTALITY AND ECHOCARDIOGRAPHIC RESPONSE IN CRT PATIENTS. Journal of the American College of Cardiology, 69, 813. NELSON, G. 1993. A brief history of cardiac pacing. Texas Heart Institute Journal, 20, 12. NG, A. C., ALLMAN, C., VIDAIC, J., TIE, H., HOPKINS, A. P. & LEUNG, D. Y. 2009. Long-term impact of right ventricular septal versus apical pacing on left ventricular synchrony and function in patients with second-or third-degree heart block. American Journal of Cardiology, 103, 1096-1101. NICE 2014a. Dual-chamber pacemakers for symptomatic bradycardia due to sick sinus syndrome without atrioventricular block (TA324). In: EXCELLENCE, N. I. F. H. A. C. (ed.). London: NICE. NICE 2014b. Dual‑chamber pacemakers for symptomatic bradycardia due to sick sinus syndrome and/or atrioventricular block Technology appraisal guidance [TA88]. In: EXCELLENCE, N. I. F. H. A. C. (ed.). NICE 2017. Dual-chamber pacemakers for symptomatic bradycardia due to sick sinus syndrome and/or atrioventricular block. NICOR 2016. National Audit of Cardiac Rhythm Management Devices. NICOR 2019. National Audit of Cardiac Rhythm Management Device and Ablation. In: RESEARCH, N. I. F. C. O. (ed.). NIELSEN, J. C., BØTTCHER, M., NIELSEN, T. T., PEDERSEN, A. K. & ANDERSEN, H. R. 2000. Regional myocardial blood flow in patients with sick sinus syndrome randomized to long-term single chamber atrial or dual chamber pacing—effect of pacing mode and rate. Journal of the American College of Cardiology, 35, 1453-1461. NIELSEN, J. C., KRISTENSEN, L., ANDERSEN, H. R., MORTENSEN, P. T., PEDERSEN, O. L. & PEDERSEN, A. K. 2003. A randomized comparison ofatrial and dual-chamber pacing in177 consecutive patients with sick sinus syndrome: Echocardiographic and clinical outcome. Journal of the American College of Cardiology, 42, 614-623. NIELSEN, J. C., THOMSEN, P. E. B., HØJBERG, S., MØLLER, M., RIAHI, S., DALSGAARD, D., MORTENSEN, L. S., NIELSEN, T., ASKLUND, M. & FRIIS, E. V. 2012. Atrial fibrillation in patients with sick sinus syndrome: the association with PQ-interval and percentage of ventricular pacing. Europace, 14, 682-689. NIELSEN, J. C., THOMSEN, P. E. B., HØJBERG, S., MØLLER, M., VESTERLUND, T., DALSGAARD, D., MORTENSEN, L. S., NIELSEN, T., ASKLUND, M. & FRIIS, E. V. 2011. A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome. European heart journal, 32, 686-696. NUTTER, D. 1978. Measuring and recording systemic blood pressure. The heart, 4, 220-2. OCCHETTA, E., BORTNIK, M., MAGNANI, A., FRANCALACCI, G., PICCININO, C., PLEBANI, L. & MARINO, P. 2006. Prevention of ventricular desynchronization by permanent para-Hisian pacing after atrioventricular node ablation in chronic atrial fibrillation: a crossover, blinded, randomized study versus apical right ventricular pacing. Journal of the American College of Cardiology, 47, 1938-1945. OWAN, T. E., HODGE, D. O., HERGES, R. M., JACOBSEN, S. J., ROGER, V. L. & REDFIELD, M. M. 2006. Trends in prevalence and outcome of heart failure with preserved ejection fraction. New England Journal of Medicine, 355, 251-259. PACKER, M., ANTONOPOULOS, G. V., BERLIN, J. A., CHITTAMS, J., KONSTAM, M. A. & UDELSON, J. E. 2001. Comparative effects of carvedilol and metoprolol on left ventricular ejection fraction in heart failure: results of a meta-analysis. American heart journal, 141, 899-907. PADELETTI, L., PIERAGNOLI, P., DI BIASE, L., COLELLA, A., LANDOLINA, M., MORO, E., ORAZI, S., VICENTINI, A., MAGLIA, G. & PENSABENE, O. 2006. Is a dual‐sensor pacemaker appropriate in patients with sino‐atrial disease? Results from the DUSISLOG study. Pacing and clinical electrophysiology, 29, 34-40. PAP, R., GALLARDO, R., RÓNASZÉKI, D., ÁGOSTON, G., TRAYKOV, V. B., SÁGHY, L., VARGA, A. & FORSTER, T. 2012. The role of pacing-induced dyssynchrony in left ventricular remodeling associated with long-term right ventricular pacing for atrioventricular block. Journal of electrocardiology, 45, 357-360. PARK, J. J., PARK, J.-B., PARK, J.-H. & CHO, G.-Y. 2018. Global longitudinal strain to predict mortality in patients with acute heart failure. Journal of the American College of Cardiology, 71, 1947-1957. PASCALE, P., PRUVOT, E. & GRAF, D. 2009. Pacemaker syndrome during managed ventricular pacing mode: what is the mechanism? Journal of cardiovascular electrophysiology, 20, 574-576. PATON, M. F., LANDOLINA, M., BILLUART, J.-R., FIELD, D., SIBLEY, J. & WITTE, K. 2019. Projected longevities of cardiac implantable defibrillators: a retrospective analysis over the period 2007–17 and the impact of technological factors in determining longevity. EP Europace. PERNEGER, T. V. 1998. What's wrong with Bonferroni adjustments. Bmj, 316, 1236-1238. PLOUX, S., LUMENS, J., WHINNETT, Z., MONTAUDON, M., STROM, M., RAMANATHAN, C., DERVAL, N., ZEMMOURA, A., DENIS, A. & DE GUILLEBON, M. 2013. Noninvasive electrocardiographic mapping to improve patient selection for cardiac resynchronization therapy: beyond QRS duration and left bundle branch block morphology. Journal of the American College of Cardiology, 61, 2435-2443. PONIKOWSKI, P., VOORS, A. A., ANKER, S. D., BUENO, H., CLELAND, J. G., COATS, A. J., FALK, V., GONZÁLEZ‐JUANATEY, J. R., HARJOLA, V. P. & JANKOWSKA, E. A. 2016. 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC). Developed with the special contribution of the Heart Failure Association (HFA) of the ESC. European journal of heart failure, 18, 891-975. POTTER, E. & MARWICK, T. H. 2018. Assessment of left ventricular function by echocardiography: the case for routinely adding global longitudinal strain to ejection fraction. JACC: Cardiovascular Imaging, 11, 260-274. PRINZEN, F. W., HUNTER, W. C., WYMAN, B. T. & MCVEIGH, E. R. 1999. Mapping of regional myocardial strain and work during ventricular pacing: experimental study using magnetic resonance imaging tagging. J Am Coll Cardiol, 33, 1735-42. RAATIKAINEN, M. P., ARNAR, D. O., ZEPPENFELD, K., MERINO, J. L., LEVYA, F., HINDRIKS, G. & KUCK, K.-H. 2015. Statistics on the use of cardiac electronic devices and electrophysiological procedures in the European Society of Cardiology countries: 2014 report from the European Heart Rhythm Association. Ep Europace, 17, i1-i75. RAJAPPAN, K. 2009a. Permanent pacemaker implantation technique: part I. Heart, 95, 259-264. RAJAPPAN, K. 2009b. Permanent pacemaker implantation technique: part II. Heart, 95, 334-342. RANGANATHAN, N., DHURANDHAR, R., PHILLIPS, J. & WIGLE, E. 1972. His Bundle electrogram in bundle-branch block. Circulation, 45, 282-294. RASMUSSEN, K. 1981. Chronic sinus node disease: natural course and indications for pacing. European heart journal, 2, 455-459. RICCI, R. P., BOTTO, G. L., BÉNÉZET, J. M., NIELSEN, J. C., DE ROY, L., PIOT, O., QUESADA, A., QUAGLIONE, R., VACCARI, D. & MANGONI, L. 2015. Association between ventricular pacing and persistent atrial fibrillation in patients indicated to elective pacemaker replacement: Results of the Prefer for Elective Replacement MVP (PreFER MVP) randomized study. Heart Rhythm, 12, 2239-2246. RIEGEL, B., MOSER, D. K., GLASER, D., CARLSON, B., DEATON, C., ARMOLA, R., SETHARES, K., SHIVELY, M., EVANGELISTA, L. & ALBERT, N. 2002. The Minnesota Living With Heart Failure Questionnaire: sensitivity to differences and responsiveness to intervention intensity in a clinical population. Nursing research, 51, 209-218. ROBERTS, P. R. 2005. Follow up and optimisation of cardiac pacing. Heart, 91, 1229-1234. RUBAJ, A., RUCINSKI, P., SODOLSKI, T., BILAN, A., GULAJ, M., DABROWSKA‐KUGACKA, A. & KUTARSKI, A. 2010. Comparison of the Acute Hemodynamic Effect of Right Ventricular Apex, Outflow Tract, and Dual‐Site Right Ventricular Pacing. Annals of Noninvasive Electrocardiology, 15, 353-359. SAITO, M., KAYE, G., NEGISHI, K., LINKER, N., GAMMAGE, M., KOSMALA, W. & MARWICK, T. H. 2015. Dyssynchrony, contraction efficiency and regional function with apical and non-apical RV pacing. Heart, 101, 600-608. SARVARI, S. I., SITGES, M., SANZ, M., TOLOSANA VIU, J. M., EDVARDSEN, T., STOKKE, T. M., MONT, L. & BIJNENS, B. 2017. Left ventricular dysfunction is related to the presence and extent of a septal flash in patients with right ventricular pacing. EP Europace, 19, 289-296. SASAKI, Y., SHIMOTORI, M., AKAHANE, K., YONEKURA, H., HIRANO, K., ENDOH, R., KOIKE, S., KAWA, S., FURUTA, S. & HOMMA, T. 1988. Long‐term follow‐up of patients with sick sinus syndrome: A comparison of clinical aspects among unpaced, ventricular inhibited paced, and physiologically paced groups. Pacing and Clinical Electrophysiology, 11, 1575-1583. SAUNDERSON, C. P., MF; GIERULA, J; BROWN, LAE; GREENWOOD, JP; KOSHY, A; CRAVEN, TP; CHEW, P; DA,S A; LEVELT, E; DALL’ARMELLINA, E; WITTE, KK; PLEIN, S AND SWOBODA, P. 2019. Prevalence and distribution of cardiac fibrosis in patients with atrioventricular block undergoing pacemaker implantation. European Journal of Arrhythmia and Electrophysiology, 5, abstr.59. SAVOURE, A., FROHLIG, G., GALLEY, D., DEFAYE, P., REUTER, S., MABO, P., SADOUL, N., AMBLARD, A., LIMOUSIN, M. & ANSELME, F. 2005. A new dual-chamber pacing mode to minimize ventricular pacing. Pacing Clin Electrophysiol, 28 Suppl 1, S43-6. SCHWAAB, B., FRÖHLIG, G., SCHWERDT, H., HEISEL, A., BERG, M. & SCHIEFFER, H. 1998. Telemetry guided pacemaker programming: impact of output amplitude and the use of low threshold leads on projected pacemaker longevity. Pacing and clinical electrophysiology, 21, 2055-2063. SHARMA, A. D., RIZO-PATRON, C., HALLSTROM, A. P., O’NEILL, G. P., ROTHBART, S., MARTINS, J. B., ROELKE, M., STEINBERG, J. S., GREENE, H. L. & INVESTIGATORS, D. 2005. Percent right ventricular pacing predicts outcomes in the DAVID trial. Heart rhythm, 2, 830-834. SHEN, W.-K., HAMMILL, S. C., HAYES, D. L., PACKER, D. L., BAILEY, K. R., BALLARD, D. J. & GERSH, B. J. 1994. Long-term survival after pacemaker implantation for heart block in patients≥ 65 years. The American journal of cardiology, 74, 560-564. SHEN, W.-K., HAYES, D. L., HAMMILL, S. C., BAILEY, K. R., BALLARD, D. J. & GERSH, B. J. 1996. Survival and functional independence after implantation of a permanent pacemaker in octogenarians and nonagenarians: a population-based study. Annals of internal medicine, 125, 476-480. SHUKLA, H. H., HELLKAMP, A. S., JAMES, E. A., FLAKER, G. C., LEE, K. L., SWEENEY, M. O. & LAMAS, G. A. 2005. Heart failure hospitalization is more common in pacemaker patients with sinus node dysfunction and a prolonged paced QRS duration. Heart Rhythm, 2, 245-251. SILVERMAN, B. G., GROSS, T. P., KACZMAREK, R. G., HAMILTON, P. & HAMBURGER, S. 1995. The epidemiology of pacemaker implantation in the United States. Public Health Reports, 110, 42. SIMANTIRAKIS, E. N., KOCHIADAKIS, G. E., VARDAKIS, K. E., IGOUMENIDIS, N. E., CHRYSOSTOMAKIS, S. I. & VARDAS, P. E. 2003. Left ventricular mechanics and myocardial blood flow following restoration of normal activation sequence in paced patients with long-term right ventricular apical stimulation. Chest, 124, 233-241. STAMBLER, B. S., ELLENBOGEN, K. A., ZHANG, X., PORTER, T. R., XIE, F., MALIK, R., SMALL, R., BURKE, M., KAPLAN, A. & NAIR, L. 2003. Right ventricular outflow versus apical pacing in pacemaker patients with congestive heart failure and atrial fibrillation. Journal of cardiovascular electrophysiology, 14, 1180-1186. STANTON, T., LEANO, R. & MARWICK, T. H. 2009. Prediction of all-cause mortality from global longitudinal speckle strain: comparison with ejection fraction and wall motion scoring. Circulation: Cardiovascular Imaging, 2, 356-364. STEFANI, L., TONCELLI, L., GIANASSI, M., MANETTI, P., DI TANTE, V., VONO, M. R. C., MORETTI, A., CAPPELLI, B., PEDRIZZETTI, G. & GALANTI, G. 2007. Two-dimensional tracking and TDI are consistent methods for evaluating myocardial longitudinal peak strain in left and right ventricle basal segments in athletes. Cardiovascular ultrasound, 5, 7. STOCKBURGER, M., BOVEDA, S., MORENO, J., DA COSTA, A., HATALA, R., BRACHMANN, J., BUTTER, C., GARCIA SEARA, J., ROLANDO, M. & DEFAYE, P. 2014. Long-term clinical effects of ventricular pacing reduction with a changeover mode to minimize ventricular pacing in a general pacemaker population. European heart journal, 36, 151-157. STOCKBURGER, M., DEFAYE, P., BOVEDA, S., STANCAK, B., LAZARUS, A., SIPÖTZ, J., NARDI, S., ROLANDO, M. & MORENO, J. 2015. Safety and efficiency of ventricular pacing prevention with an AAI-DDD changeover mode in patients with sinus node disease or atrioventricular block: impact on battery longevity—a sub-study of the ANSWER trial. Ep Europace, 18, 739-746. STOKES, K. 1985. The electrode-biointerface: stimulation. Modern cardiac pacing., 33-77. SULKE, N., CHAMBERS, J., DRITSAS, A. & SOWTON, E. 1991. A randomized double-blind crossover comparison of four rate-responsive pacing modes. Journal of the American College of Cardiology, 17, 696-706. SWEENEY, M. 2007. Search AV Extension and Managed Ventricular Pacing for Promoting Atrioventricular Conduction (SAVE PACe) Trial. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. N Engl J Med, 357, 1000-1008. SWEENEY, M. O., BANK, A. J., NSAH, E., KOULLICK, M., ZENG, Q. C., HETTRICK, D., SHELDON, T. & LAMAS, G. A. 2007. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. New England Journal of Medicine, 357, 1000-1008. SWEENEY, M. O., ELLENBOGEN, K. A., CASAVANT, D., BETZOLD, R., SHELDON, T., TANG, F., MUELLER, M., LINGLE, J. & INVESTIGATORS, M. M. D. 2005a. Multicenter, prospective, randomized safety and efficacy study of a new atrial‐based managed ventricular pacing mode (MVP) in dual chamber ICDs. Journal of cardiovascular electrophysiology, 16, 811-817. SWEENEY, M. O., ELLENBOGEN, K. A., TANG, A. S., WHELLAN, D., MORTENSEN, P. T., GIRALDI, F., SANDLER, D. A., SHERFESEE, L., SHELDON, T. & VVI, M. V. P. V. 2010. Atrial pacing or ventricular backup–only pacing in implantable cardioverter-defibrillator patients. Heart Rhythm, 7, 1552-1560. SWEENEY, M. O., HELLKAMP, A. S., ELLENBOGEN, K. A., GREENSPON, A. J., FREEDMAN, R. A., LEE, K. L. & LAMAS, G. A. 2003. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation, 107, 2932-2937. SWEENEY, M. O., HELLKAMP, A. S., ELLENBOGEN, K. A. & LAMAS, G. A. 2008. Reduced ejection fraction, sudden cardiac death, and heart failure death in the mode selection trial (MOST): implications for device selection in elderly patients with sinus node disease. Journal of cardiovascular electrophysiology, 19, 1160-1166. SWEENEY, M. O., HELLKAMP, A. S., LEE, K. L. & LAMAS, G. A. 2005b. Association of prolonged QRS duration with death in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation, 111, 2418-2423. SWEENEY, M. O. & PRINZEN, F. W. 2006. A new paradigm for physiologic ventricular pacing. J Am Coll Cardiol, 47, 282-8. TAYAL, B., FRUELUND, P., SOGAARD, P., RIAHI, S., POLCWIARTEK, C., ATWATER, B. D., GISLASON, G., RISUM, N., TORP-PEDERSEN, C. & KOBER, L. 2019. Incidence of heart failure after pacemaker implantation: a nationwide Danish Registry-based follow-up study. European heart journal, 40, 3641-3648. THACKRAY, S. D., WITTE, K. K., NIKITIN, N. P., CLARK, A. L., KAYE, G. C. & CLELAND, J. G. 2003. The prevalence of heart failure and asymptomatic left ventricular systolic dysfunction in a typical regional pacemaker population. European Heart Journal, 24, 1143-1152. TOFF, W. D., CAMM, A. J. & SKEHAN, J. D. 2005. Single-chamber versus dual-chamber pacing for high-grade atrioventricular block. New England Journal of Medicine, 353, 145-155. TOPS, L. F., SCHALIJ, M. J., HOLMAN, E. R., VAN ERVEN, L., VAN DER WALL, E. E. & BAX, J. J. 2006. Right ventricular pacing can induce ventricular dyssynchrony in patients with atrial fibrillation after atrioventricular node ablation. J Am Coll Cardiol, 48, 1642-8. TORRES-AYALA, S. C., SANTACANA-LAFFITTE, G. & MALDONADO, J. 2014. Radiography of cardiac conduction devices: a pictorial review of pacemakers and implantable cardioverter defibrillators. Journal of clinical imaging science, 4. TRAPPE, H.-J., KLEIN, H., FRANK, G. & LICHTEN, P. 1988. Rate-responsive pacing as compared to fixed-rate VVI pacing in patients after ablation of the atrioventricular conduction system. European heart journal, 9, 642-648. TRIAL, S.-H. 1999. CIBIS-II Trial. Lancet, 353, 9-13. TSE, H.-F. & LAU, C.-P. 1997a. Long-term effect of right ventricular pacing on myocardial perfusion and function. Journal of the American College of Cardiology, 29, 744-749. TSE, H.-F., YU, C., WONG, K.-K., TSANG, V., LEUNG, Y.-L., HO, W.-Y. & LAU, C.-P. 2002. Functional abnormalities in patients with permanent right ventricular pacing: the effect of sites of electrical stimulation. Journal of the American College of Cardiology, 40, 1451-1458. TSE, H. F. & LAU, C. P. 1997b. Long-term effect of right ventricular pacing on myocardial perfusion and function. J Am Coll Cardiol, 29, 744-9. TYERS, G. 2011. Actual pacemaker longevity: the benefit of stimulation by automatic capture verification. Pacing and clinical electrophysiology: PACE, 34, 389; author reply 389-90. UDO, E. O., VAN HEMEL, N. M., ZUITHOFF, N. P., DIJK, W. A., HOOIJSCHUUR, C. A., DOEVENDANS, P. A. & MOONS, K. G. 2013. Pacemaker follow-up: are the latest guidelines in line with modern pacemaker practice? Europace, 15, 243-251. UDO, E. O., VAN HEMEL, N. M., ZUITHOFF, N. P., DOEVENDANS, P. A. & MOONS, K. G. 2015. Risk of heart failure-and cardiac death gradually increases with more right ventricular pacing. International journal of cardiology, 185, 95-100. USLAN, D. Z., GLEVA, M. J., WARREN, D. K., MELA, T., CHUNG, M. K., GOTTIPATY, V., BORGE, R., DAN, D., SHINN, T. & MITCHELL, K. 2012. Cardiovascular implantable electronic device replacement infections and prevention: results from the REPLACE Registry. Pacing and Clinical Electrophysiology, 35, 81-87. VAN DE VEN, L. L., VAN VELDHUISEN, D. J., GOULDER, M., ZILAHI, Z., MEYER, W. R. & WILLENHEIMER, R. 2010. The effect of treatment with bisoprolol-first versus enalapril-first on cardiac structure and function in heart failure. International journal of cardiology, 144, 59-63. VAN ECK, J. M., VAN HEMEL, N. M., VAN DEN BOS, A., TAKS, W., GROBBEE, D. E. & MOONS, K. G. 2008a. Predictors of improved quality of life 1 year after pacemaker implantation. American heart journal, 156, 491-497. VAN ECK, J. W., VAN HEMEL, N. M., DE VOOGT, W. G., MEEDER, J. G., SPIERENBURG, H. A., CROMMENTUYN, H., KEIJZER, R., GROBBEE, D. E. & MOONS, K. G. 2008b. Routine follow-up after pacemaker implantation: frequency, pacemaker programming and professionals in charge. Europace, 10, 832-837. VAN GELDORP, I. E., DELHAAS, T., GEBAUER, R. A., FRIAS, P., TOMASKE, M., FRIEDBERG, M. K., TISMA-DUPANOVIC, S., ELDERS, J., FRÜH, A. & GABBARINI, F. 2011. Impact of the permanent ventricular pacing site on left ventricular function in children: a retrospective multicentre survey. Heart, heartjnl-2011-300197. VAN OOSTERHOUT, M. F., PRINZEN, F. W., ARTS, T., SCHREUDER, J. J., VANAGT, W. Y., CLEUTJENS, J. P. & RENEMAN, R. S. 1998. Asynchronous electrical activation induces asymmetrical hypertrophy of the left ventricular wall. Circulation, 98, 588-595. VANVOORHIS, C. W. & MORGAN, B. L. 2007. Understanding power and rules of thumb for determining sample sizes. Tutorials in quantitative methods for psychology, 3, 43-50. VARDAS, P. E., AURICCHIO, A., BLANC, J.-J., DAUBERT, J.-C., DREXLER, H., ECTOR, H., GASPARINI, M., LINDE, C., MORGADO, F. B. & OTO, A. 2007. Guidelines for cardiac pacing and cardiac resynchronization therapy: the task force for cardiac pacing and cardiac resynchronization therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association. European heart journal, 28, 2256-2295. VICTOR, F., LECLERCQ, C., MABO, P., PAVIN, D., DEVILLER, A., DE PLACE, C., PEZARD, P., VICTOR, J. & DAUBERT, C. 1999. Optimal right ventricular pacing site in chronically implanted patients: a prospective randomized crossover comparison of apical and outflow tract pacing. Journal of the American College of Cardiology, 33, 311-316. VIJAYARAMAN, P., DANDAMUDI, G., LUSTGARTEN, D. & ELLENBOGEN, K. A. 2017. Permanent his bundle pacing: Electrophysiological and echocardiographic observations from long‐term follow‐up. Pacing and Clinical Electrophysiology. VOIGT, J.-U., EXNER, B., SCHMIEDEHAUSEN, K., HUCHZERMEYER, C., REULBACH, U., NIXDORFF, U., PLATSCH, G. N., KUWERT, T., DANIEL, W. G. & FLACHSKAMPF, F. A. 2003. Strain-rate imaging during dobutamine stress echocardiography provides objective evidence of inducible ischemia. Circulation, 107, 2120-2126. VOIGT, J.-U., PEDRIZZETTI, G., LYSYANSKY, P., MARWICK, T. H., HOULE, H., BAUMANN, R., PEDRI, S., ITO, Y., ABE, Y. & METZ, S. 2014. Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. European Heart Journal-Cardiovascular Imaging, 16, 1-11. VOIGT, J.-U., SCHNEIDER, T.-M., KORDER, S., SZULIK, M., GÜREL, E., DANIEL, W. G., RADEMAKERS, F. & FLACHSKAMPF, F. A. 2009. Apical transverse motion as surrogate parameter to determine regional left ventricular function inhomogeneities: a new, integrative approach to left ventricular asynchrony assessment. European heart journal, 30, 959-968. WEIZONG, W., ZHONGSU, W., YUJIAO, Z., MEI, G., JIANGRONG, W., YONG, Z., XINXING, X. & YINGLONG, H. 2013. Effects of right ventricular nonapical pacing on cardiac function: a meta‐analysis of randomized controlled trials. Pacing and Clinical Electrophysiology, 36, 1032-1051. WENZL, M. & MOSSIALOS, E. 2018. Prices for cardiac implant devices may be up to six times higher in the US than in some European countries. Health Affairs, 37, 1570-1577. WESSLER, B. S., KRAMER, D. G., KELLY, J. L., TRIKALINOS, T. A., KENT, D. M., KONSTAM, M. A. & UDELSON, J. E. 2011. Drug and device effects on peak oxygen consumption, 6-minute walk distance, and natriuretic peptides as predictors of therapeutic effects on mortality in patients with heart failure and reduced ejection fraction. Circulation: Heart Failure, 4, 578-588. WHARTON, G., STEEDS, R., ALLEN, J., PHILLIPS, H., JONES, R., KANAGALA, P., LLOYD, G., MASANI, N., MATHEW, T. & OXBOROUGH, D. 2015. A minimum dataset for a standard adult transthoracic echocardiogram: a guideline protocol from the British Society of Echocardiography. Echo Research and Practice, 2, G9-G24. WIGGERS, C. J. 1925. The muscular reactions of the mammalian ventricles to artificial surface stimuli. American Journal of Physiology-Legacy Content, 73, 346-378. WILD, D. M., FISHER, J. D., KIM, S. G., FERRICK, K. J., GROSS, J. N. & PALMA, E. C. 2004. Pacemakers and implantable cardioverter defibrillators: device longevity is more important than smaller size: the patient's viewpoint. Pacing and clinical electrophysiology, 27, 1526-1529. WILKOFF, B. L., AURICCHIO, A., BRUGADA, J., COWIE, M., ELLENBOGEN, K. A., GILLIS, A. M., HAYES, D. L., HOWLETT, J. G., KAUTZNER, J. & LOVE, C. J. 2008. HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs): description of techniques, indications, personnel, frequency and ethical considerations: developed in partnership with the Heart Rhythm Society (HRS) and the European Heart Rhythm Association (EHRA); and in collaboration with the American College of Cardiology (ACC), the American Heart Association (AHA), the European Society of Cardiology (ESC), the Heart Failure Association of ESC (HFA), and the Heart Failure Society of America (HFSA). Endorsed by the Heart Rhythm Society, the European Heart Rhythm Association (a registered branch of the ESC), the American College of Cardiology, the American Heart Association. Europace, 10, 707-725. WILKOFF, B. L., COOK, J. R., EPSTEIN, A. E., GREENE, H. L., HALLSTROM, A. P., HSIA, H., KUTALEK, S. P., SHARMA, A., DUAL, C. & INVESTIGATORS, V. V. I. I. D. T. 2002. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA, 288, 3115-23. WILKOFF, B. L., KUDENCHUK, P. J., BUXTON, A. E., SHARMA, A., COOK, J. R., BHANDARI, A. K., BIEHL, M., TOMASSONI, G., LEONEN, A. & KLEVAN, L. R. 2009. The DAVID (dual chamber and VVI implantable defibrillator) II trial. Journal of the American College of Cardiology, 53, 872-880. WITTE, K. K., BYROM, R., GIERULA, J., PATON, M. F., JAMIL, H. A., LOWRY, J. E., GILLOTT, R. G., BARNES, S. A., CHUMUN, H. & KEARNEY, L. C. 2016. Effects of vitamin D on cardiac function in patients with chronic HF: the VINDICATE study. Journal of the American College of Cardiology, 67, 2593-2603. WOLBER, T., HAEGELI, L., HUERLIMANN, D., BRUNCKHORST, C., LUESCHER, T. F. & DURU, F. 2011. Altered Left Ventricular Contraction Pattern during Right Ventricular Pacing: Assessment Using Real‐Time Three‐Dimensional Echocardiography. Pacing and clinical electrophysiology, 34, 76-81. WOOD, M. A. & ELLENBOGEN, K. A. 2002. Cardiac pacemakers from the patient’s perspective. Circulation, 105, 2136-2138. YINGCHONCHAROEN, T., AGARWAL, S., POPOVIĆ, Z. B. & MARWICK, T. H. 2013. Normal ranges of left ventricular strain: a meta-analysis. Journal of the American Society of Echocardiography, 26, 185-191. YU, C.-M., BLEEKER, G. B., FUNG, J. W.-H., SCHALIJ, M. J., ZHANG, Q., VAN DER WALL, E. E., CHAN, Y.-S., KONG, S.-L. & BAX, J. J. 2005. Left ventricular reverse remodeling but not clinical improvement predicts long-term survival after cardiac resynchronization therapy. Circulation, 112, 1580-1586. YU, C.-M., CHAN, J. Y.-S., ZHANG, Q., OMAR, R., YIP, G. W.-K., HUSSIN, A., FANG, F., LAM, K. H., CHAN, H. C.-K. & FUNG, J. W.-H. 2009. Biv"],"dcterms:accessrights":["public"],"dc:title":["Is pacemaker-induced cardiac dysfunction progressive and reversible in patients receiving long-term pacemaker therapy?"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000185174621"]},"updated_at":"2026-11-18T22:41:20Z"}