{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:28567"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:28567","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Computational Modelling in the Management of Patients with Aortic Valve Stenosis","abstract":"Background Stenosis of the aortic valve causes increased left ventricular pressure leading to adverse clinical outcomes. The selection and timing of intervention (surgical replacement or transcatheter implantation) is often unclear and is based upon limited data. Hypothesis A comprehensive and integrated personalised approach, including recognition of cardiac energetics parameters extracted from a personalised mathematical model, mapped to patient activity, has the potential to improve diagnosis and the planning and timing of interventions. Aims This project seeks to implement a simple, personalised, mathematical model of patients with aortic stenosis (AS), which can ‘measure’ cardiac work and power parameters that provide an effective characterisation of the demand on the heart in both rest and exercise conditions and can predict the changes of these parameters following an intervention. The specific aims of this project are: • to critically review current diagnostic methods • to evaluate the potential role of pre- and post-procedural measured patient activity • to implement a simple, personalised, mathematical model of patients with AS • to evaluate the potential role of a clinical decision support system Methods Twenty-two patients with severe AS according to ESC criteria were recruited. Relevant clinical, imaging, activity monitoring, six-minute walk test, and patient reported data were collected, before and early and after treatment. Novel imaging techniques were developed to help in the diagnosis of AS. A computational model was developed and executed using the data collected to create non-invasive pressure volume loops and study the global haemodynamic burden on the left ventricle. Simulations were run to predict the haemodynamic parameters both during exercise and following intervention. Modelled parameters were validated against clinically measured values. This information was then correlated with symptoms and activity data. A clinical decision support tool was created and populated with data obtained and its clinical utility evaluated. Outcomes The results of this project suggest that the combination of imaging and activity data with computational modelling provides a novel, patient-specific insight into patients’ haemodynamics and may help guide clinical decision making in patients with AS.","abstract_html":"Background Stenosis of the aortic valve causes increased left ventricular pressure leading to adverse clinical outcomes. The selection and timing of intervention (surgical replacement or transcatheter implantation) is often unclear and is based upon limited data. Hypothesis A comprehensive and integrated personalised approach, including recognition of cardiac energetics parameters extracted from a personalised mathematical model, mapped to patient activity, has the potential to improve diagnosis and the planning and timing of interventions. Aims This project seeks to implement a simple, personalised, mathematical model of patients with aortic stenosis (AS), which can ‘measure’ cardiac work and power parameters that provide an effective characterisation of the demand on the heart in both rest and exercise conditions and can predict the changes of these parameters following an intervention. The specific aims of this project are: • to critically review current diagnostic methods • to evaluate the potential role of pre- and post-procedural measured patient activity • to implement a simple, personalised, mathematical model of patients with AS • to evaluate the potential role of a clinical decision support system Methods Twenty-two patients with severe AS according to ESC criteria were recruited. Relevant clinical, imaging, activity monitoring, six-minute walk test, and patient reported data were collected, before and early and after treatment. Novel imaging techniques were developed to help in the diagnosis of AS. A computational model was developed and executed using the data collected to create non-invasive pressure volume loops and study the global haemodynamic burden on the left ventricle. Simulations were run to predict the haemodynamic parameters both during exercise and following intervention. Modelled parameters were validated against clinically measured values. This information was then correlated with symptoms and activity data. A clinical decision support tool was created and populated with data obtained and its clinical utility evaluated. Outcomes The results of this project suggest that the combination of imaging and activity data with computational modelling provides a novel, patient-specific insight into patients’ haemodynamics and may help guide clinical decision making in patients with AS.","abstract_has_math":false,"creators":["Archer, Gareth Trevor"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Gunn, Julian","Briffa, Norman","Hose, Rod"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-05","date_published":"2020-05","updated_at":"2026-11-18T22:41:35Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.826809"],"render_values":[{"text":"uk.bl.ethos.826809","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["H2020 PHC-30–2015, 689617"],"render_values":[{"text":"H2020 PHC-30–2015, 689617","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000318017161"],"render_values":[{"text":"0000-0003-1801-7161","href":"https://orcid.org/0000-0003-1801-7161","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/28567/1/Thesis_Final_Submission_G_Archer_04_03_21.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A28567","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gunn, Julian","Briffa, Norman","Hose, Rod"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["European Comission Horizon 2020"]},{"key":"dc:creator","label":"Author","values":["Archer, Gareth Trevor"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000318017161"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-05"]},{"key":"dc:date.issued","label":"Date","values":["2020-05"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Faculty of Health (Sheffield)","Medicine (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/28567/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] S. J. Choo, G. McRae, J.Olomon et al. “Aortic root geometry: pattern of differences between leaflets and sinuses of Valsalva.,” J. Heart Valve Dis., vol. 8, no. 4, pp. 407–15, 1999. [2] Wikimedia Commons. \"Diagram of the human heart\" (Online). Available: https://commons.wikimedia.org/wiki/File:Diagram_of_the_human_heart.svg (Accessed: 10-Feb-2018). [3] M. J. Thubrikar, S. P. Nolan, J. Aouad, and J. D. Deck. “Stress sharing between the sinus and leaflets of canine aortic valve.,” Ann. Thorac. Surg., vol. 42, no. 4, pp. 434–40, 1986. [4] A. Hamdan, V. Guetta, Konen, Eli et al. “Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: Insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy,” J. Am. Coll. Cardiol., vol. 59, no. 2, pp. 119–127, 2012. [5] M. Misfeld and H. H. Sievers. “Heart valve macro- and microstructure,” Philosophical Transactions of the Royal Society B: Biological Sciences, vol. 362, no. 1484. Royal Society, pp. 1421–1436, 2007. [6] D. A. Watkins, C. Johnson, S. Colquhoun et al. “Global, Regional, and National Burden of Rheumatic Heart Disease, 1990–2015,” N. Engl. J. Med., vol. 377, no. 8, pp. 713–722, 2017. [7] P. G. Supino, J. S. Borer, J. Preibisz, and A. Bornstein, “The Epidemiology of Valvular Heart Disease: a Growing Public Health Problem,” Heart Fail. Clin., vol. 2, no. 4, pp. 379–393, 2006. [8] Heart Valve Voice . “Giving a voice to those with heart valve disease.,” A Heart Valve Voice White Paper. 2014. [9] P. Faggiano, F. Antonini-Canterin, F. Baldessin et al. “Epidemiology and cardiovascular risk factors of aortic stenosis,” Cardiovasc. Ultrasound, vol. 4, 2006. [10] J. L. D’Arcy, S. Coffey, M. A. Loudon et al. “Large-scale community echocardiographic screening reveals a major burden of undiagnosed valvular heart disease in older people: The OxVALVE Population Cohort Study,” Eur. Heart J., vol. 37, no. 47, pp. 3515-3522a, 2016. [11] G. A. Roth, D. Abate, H. Abate et al. “Global, regional, and national age-sex-specific mortality for 282 causes of death in 195 countries and territories, 1980-2017: a systematic analysis for the Global Burden of Disease Study 2017\". Lancet, vol 392, pp.1736–88, 2018. [12] S. N. Vaslef and W. C. Roberts. “Early descriptions of aortic stenosis,” Am. Heart J., vol. 125, pp. 1475–1483, 1993. [13] J. G. Mönckeberg. “Der normale histologische Bau und die Sklerose der Aortenklappen,” Virchows Arch. Pathol. Anat. Physiol. Klin. Med., vol. 176, no. 3, pp. 472–514, 1904. [14] N. M. Rajamannan. “Update on the pathophysiology of aortic stenosis,” Eur. Hear. J. Suppl., vol. 10, no. suppl_E, pp. E4–E10, 2008. [15] T. A. Pawade, D. E. Newby, and M. R. Dweck. “Calcification in aortic stenosis: The skeleton key,” J. Am. Coll. Cardiol., vol. 66, no. 5, pp. 561–577, 2015. [16] M. R. Dweck, N. A. Boon, and D. E. Newby. “Calcific aortic stenosis: A disease of the valve and the myocardium,” J. Am. Coll. Cardiol., vol. 60, no. 19. pp. 1854–1863, 2012. [17] C. M. Otto, J. Kuusisto, D. D. Reichenbach et al. “Characterization of the early lesion of ‘degenerative’ valvular aortic stenosis: Histological and immunohistochemical studies,” Circulation, vol. 90, no. 2, pp. 844–853, 1994. [18] R. A. Nishimura, J. A. Grantham, H. M. Connolly et al. “Low-output, low-gradient aortic stenosis in patients with depressed left ventricular systolic function: the clinical utility of the dobutamine challenge in the catheterization laboratory.,” Circulation, vol. 106, no. 7, pp. 809–13, 2002. [19] I. G. Burwash. “Low-flow, low-gradient aortic stenosis: from evaluation to treatment,” Curr. Opin. Cardiol., vol. 22, no. 2, pp. 84–91, 2007. [20] W. J. Paulus, S. U. Sys, G. R. Heyndrickx, and E. Andries. “Orifice variability of the stenotic aortic valve: Evaluation before and after balloon aortic valvuloplasty,” J. Am. Coll. Cardiol., vol. 17, no. 6, pp. 1263–1269, 1991. [21] C. M. Otto. “Calcific Aortic Stenosis — Time to Look More Closely at the Valve,” N. Engl. J. Med., vol. 359, no. 13, pp. 1395–1398, Sep. 2008. [22] P. Pibarot and J. G. Dumesnil, “Improving assessment of aortic stenosis,” J. Am. Coll. Cardiol., vol 60, no. 3, pp. 169-180, 2012. [23] J. Chambers. “The left ventricle in aortic stenosis: evidence for the use of ACE inhibitors.,” Heart, vol. 92, no. 3, pp. 420–3, Mar. 2006. [24] B. A. Carabello, W. J. Paulus, W. J. Paulus, P. Blase, and A. Carabello, “Aortic stenosis,” Lancet, vol. 373, pp. 956–966, 2009. [25] C. W. L. Chin et al. “Myocardial Fibrosis and Cardiac Decompensation in Aortic Stenosis,” JACC Cardiovasc. Imaging, vol. 10, no. 11, pp. 1320–1333, 2017. [26] J. A. Hill and E. N. Olson. “Cardiac plasticity,” New England Journal of Medicine, vol. 358, no. 13. Massachussetts Medical Society, p. 1370, 2008. [27] R. Ramaraj and V. L. Sorrell. “Degenerative aortic stenosis.,” BMJ, vol. 336, no. 7643, pp. 550–5, 2008. [28] B. A. Carabello, L. H. Green, W. Grossman et al. “Hemodynamic determinants of prognosis of aortic valve replacement in critical aortic stenosis and advanced congestive heart failure.,” Circulation, vol. 62, no. 1, pp. 42–8, 1980. [29] H. Baumgartner et al. “2017 ESC/EACTS Guidelines for the management of valvular heart disease,” Eur. Heart J., vol. 38, no. 36, pp. 2739–2791, 2017. [30] G. P. McCann, C. D. Steadman, S. G. Ray, et al. “Managing the asymptomatic patient with severe aortic stenosis: randomised controlled trials of early surgery are overdue,” Heart, vol. 97, no. 14, pp. 1119–21, 2011. [31] R. A. Nishimura et al. “2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines,” Circulation, vol. 135, no. 25, pp. 1159–1195, 2017. [32] C. M. Otto et al. “Prospective study of asymptomatic valvular aortic stenosis. Clinical, echocardiographic, and exercise predictors of outcome.,” Circulation, vol. 95, no. 9, pp. 2262–70, May 1997. [33] F. Sotiropoulos and I. Borazjani. “A review of state-of-the-art numerical methods for simulating flow through mechanical heart valves,” Med. Biol. Eng. Comput., vol. 47, no. 3, pp. 245–256, 2009. [34] F. Schwarz, P. Baumann, J. Manthey et al. “The effect of aortic valve replacement on survival.,” Circulation, vol. 66, no. 5, pp. 1105–10, Nov. 1982. [35] J. Ross and E. Braunwald, “Aortic stenosis.,” Circulation, vol. 38, no. 1 Suppl, pp. 61–7. 1968. [36] L. Hatle, A. Brubakk, A. Tromsdal, and B. Angelsen. “Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound,” Br. Heart J., vol. 40, pp. 131–140, 1978. [37] A. P. Yoganathan, E. G. Cape, H. W. Sung et al. “Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques.,” J. Am. Coll. Cardiol., vol. 12, no. 5, pp. 1344–53, 1988. [38] F. Donati, S. Myerson, M. M. Bissell et al. “Beyond Bernoulli: Improving the Accuracy and Precision of Noninvasive Estimation of Peak Pressure Drops.,” Circ. Cardiovasc. Imaging, vol. 10, no. 1, p. e005207, 2017. [39] M. A. Clavel, J. Magne, and P. Pibarot. “Low-gradient aortic stenosis,” European Heart Journal, vol. 37, no. 34, pp. 2645–2657, 2016. [40] A.-C. Pouleur, J.-B. le Polain de Waroux, A. Pasquetet al. “Planimetric and continuity equation assessment of aortic valve area: Head to head comparison between cardiac magnetic resonance and echocardiography,” J. Magn. Reson. Imaging, vol. 26, no. 6, pp. 1436–1443, 2007. [41] A. C. Pouleur, J.B. le Polain de Waroux, A. Pasquet et al. “Aortic Valve Area Assessment: Multidetector CT Compared with Cine MR Imaging and Transthoracic and Transesophageal Echocardiography,” Radiology, vol. 244, no. 3, pp. 745–754, 2007. [42] J. Weese, A. Lungu, J. Peters et al. “CFD- and Bernoulli-based pressure drop estimates: A comparison using patient anatomies from heart and aortic valve segmentation of CT images,” Med. Phys., vol. 44, no. 6, pp. 2281–2292, 2017. [43] D. Muraru. “Impact :of 3D Echo on the Assessment of Aortic Stenosis Severity.” (online). Available https://www.escardio.org/static_file/Escardio/education/live-events/courses/imaging/3D-AS-severity-Muraru.pdf (Accessed: 18-Dec-2017). [44] M. R. Dweck, W.Jenkins, A. Vesey et al. “18F-Sodium Fluoride Uptake Is a Marker of Active Calcification and Disease Progression in Patients With Aortic Stenosis,” Circ. Cardiovasc. Imaging, vol. 7, no. 2, pp. 371–378, 2014. [45] M. A. Clavel, P. Pibarot, D. Messika-Zeitoun et al. “Impact of aortic valve calcification, as measured by MDCT, on survival in patients with aortic stenosis: Results of an international registry study,” J. Am. Coll. Cardiol., vol. 64, no. 12, pp. 1202–1213, 2014. [46] S. Plein, J. P. Greenwood, and J. P. Ridgway, Cardiovascular MR manual. Springer, 2011. [47] P. J. Cawley, J. H. Maki, and C. M. Otto, “Cardiovascular magnetic resonance imaging for valvular heart disease. Technique and validation,” Circulation, vol. 119, no. 3, pp. 468–478, 2009. [48] R. J. van der Geest and P. Garg, “Advanced Analysis Techniques for Intra-cardiac Flow Evaluation from 4D Flow MRI,” Current Radiology Reports, vol. 4, no. 7, 2016. [49] I. Valverde, S. Nordmeyer, S. Uribe et al. “Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisition,” J. Cardiovasc. Magn. Reson., vol. 14, no. 1, p. 25, 2012. [50] C. Binter, A. Gotschy, S. Sündermann et al. “Turbulent Kinetic Energy Assessed by Multipoint 4-Dimensional Flow Magnetic Resonance Imaging Provides Additional Information Relative to Echocardiography for the Determination of Aortic Stenosis Severity.,” Circ. Cardiovasc. Imaging, vol. 10, no. 6, p. e005486, 2017. [51] J. Garcia, A. J. Barker, and M. Markl, “The Role of Imaging of Flow Patterns by 4D Flow MRI in Aortic Stenosis,” JACC: Cardiovascular Imaging, vol. 12, no. 2., pp. 252–266, 01-Feb-2019. [52] B. Casas, J. Lantz, P. Dyverfeldt, and T. Ebbers, “4D Flow MRI-Based Pressure Loss Estimation in Stenotic Flows: Evaluation Using Numerical Simulations.” Magnetic Resonance in Medicine, vol. 75: pp. 1808–1821. 2016. [53] B. P. Adriaans, J. Westenberg, Y. Cauteren et al. “Clinical assessment of aortic valve stenosis: Comparison between 4D flow MRI and transthoracic echocardiography,” J. Magn. Reson. Imaging, vol. 51, no. 2, pp. 472–480, 2020. [54] M. Markl, S. Schnell, C. Wu et al. “Advanced flow MRI: emerging techniques and applications,” Clinical Radiology, vol. 71, no. 8., pp. 779–795, 2016. [55] J. Chambers, D. Bach, J. Dumesnil et al. “Crossing the aortic valve in severe aortic stenosis: no longer acceptable?,” J. Heart Valve Dis., vol. 13, no. 3, pp. 344–6, 2004. [56] M. E. Assey, M. R. Zile, B. W. Usher et al. “Effect of catheter positioning on the variability of measured gradient in aortic stenosis,” Cathet. Cardiovasc. Diagn., vol. 30, no. 4, pp. 287–92, 1993. [57] I. Ben-Dor, S. Minha, I. Barbash et al., “Correlation of Brain Natriuretic Peptide Levels in Patients With Severe Aortic Stenosis Undergoing Operative Valve Replacement or Percutaneous Transcatheter Intervention With Clinical, Echocardiographic, and Hemodynamic Factors and Prognosis,” Am. J. Cardiol., vol. 112, no. 4, pp. 574–579, 2013. [58] J. Bergler-Klein, U. Klaar, M. Heger et al. “Natriuretic peptides predict symptom-free survival and postoperative outcome in severe aortic stenosis,” Circulation, vol. 109, no. 19, pp. 2302–2308, 2004. [59] M. A. Clavel, J. Malouf, H. Michelena et al., “B-type natriuretic peptide clinical activation in aortic stenosis: Impact on long-term survival,” J. Am. Coll. Cardiol., vol. 63, no. 19, pp. 2016–2025, 2014. [60] C. W. L. Chin, A. Shah, D. McAllister, et al. “High-sensitivity troponin i concentrations are a marker of an advanced hypertrophic response and adverse outcomes in patients with aortic stenosis,” Eur. Heart J., vol. 35, no. 34, pp. 2312–2321, 2014. [61] G. Soulat, N. Kachenoura,E. Bollache et al., “New estimate of valvuloarterial impedance in aortic valve stenosis: A cardiac magnetic resonance study,” J. Magn. Reson. Imaging, vol. 45, no. 3, pp. 795–803, 2017. [62] S. Maréchaux, A. Ringle, D. Rusinaru et al. “Prognostic Value of Aortic Valve Area by Doppler Echocardiography in Patients With Severe Asymptomatic Aortic Stenosis.,” J. Am. Heart Assoc., vol. 5, no. 5, p. e003146, 2016. [63] L. M. Moura, S. F. Ramos, J Zamorano et al. “Rosuvastatin Affecting Aortic Valve Endothelium to Slow the Progression of Aortic Stenosis,” J. Am. Coll. Cardiol., vol. 49, no. 5, pp. 554–561, 2007. [64] A. B. Rossebo, T. R. Pedersen, K. Boman et al., “Intensive Lipid Lowering with Simvastatin and Ezetimibe in Aortic Stenosis,” N. Engl. J. Med., vol. 359, no. 13, pp. 1343–1356, 2008. [65] A. Hussain, A. Auensen, C. Brunborg et al. “Age-dependent morbidity and mortality outcomes after surgical aortic valve replacement'” Interactive CardioVascular and Thoracic Surgery, vol 27, no. 5, pp. 650–656, 2018. [66] M. Sarkar and V. Prabhu, “Basics of cardiopulmonary bypass,” Indian Journal of Anaesthesia, vol. 61, no. 9. pp. 760–767, 2017. [67] T. Walther, J. Blumenstein, A. Van Linden, and J. Kempfert, “Contemporary management of aortic stenosis: Surgical aortic valve replacement remains the gold standard,” Heart, vol. 98, no. Suppl. 4, pp. iv23–iv29, 01-2012. [68] Cardiac Surgery Audit Data. “SCTS Blue Book Online ” (Online). Available: http://bluebook.scts.org/. (Accessed: 28-Nov-2019). [69] M. A. Borger, V. Moustafine, L. Conradi et al. “A randomized multicenter trial of minimally invasive rapid deployment versus conventional full sternotomy aortic valve replacement,” in Annals of Thoracic Surgery, 2015, vol. 99, no. 1, pp. 17–25. [70] D. Gilmanov, A. Miceli, M. Ferrarini et al. “Aortic valve replacement through right anterior minithoracotomy: can sutureless technology improve clinical outcomes?,” Ann. Thorac. Surg., vol. 98, no. 5, pp. 1585–1592, 2014. [71] R. Chandola, K. Teoh, A. Elhenawy, and G. Christakis, “Perceval Sutureless Valve – are Sutureless Valves Here?,” Curr. Cardiol. Rev., vol. 11, no. 3, pp. 220–228, 2014. [72] T. J. Cahill, M. Chen, K. Hayashida et al. “Transcatheter aortic valve implantation: current status and future perspectives,” Eur. Heart J., vol. 39, no. 28, pp. 2625–2634, Jul. 2018. [73] R. Orlando, M. Pennant, S. Rooney et al. “Cost-effectiveness of transcatheter aortic valve implantation (TAVI) for aortic stenosis in patients who are high risk or contraindicated for surgery: A model-based economic evaluation,” Health Technology Assessment, vol. 17, no. 33. pp. 1–86, 2013. [74] M. B. Leon, C. R. Smith, M. Mack et al. “Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery,” N. Engl. J. Med., vol. 363, no. 17, pp. 1597–1607, 2010. [75] C. R. Smith, M. B. Leon, M. J. Mack et al. “Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients,” N. Engl. J. Med., vol. 364, no. 23, pp. 2187–2198, Jun. 2011. [76] M. J. Reardon et al., “Surgical or transcatheter aortic-valve replacement in intermediate-risk patients,” N. Engl. J. Med., vol. 376, no. 14, pp. 1321–1331, 2017. [77] M. J. Mack, M. B. Leon, V. H. Thourani et al. “Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients,” N. Engl. J. Med., vol. 380, no. 18, pp. 1695–1705, 2019. [78] M. J. Mack, M. B. Leon, C. R. Smith et al., “5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): A randomised controlled trial,” Lancet, vol. 385, no. 9986, pp. 2477–2484, 2015. [79] E. Spitzer, N. M. Van Mieghem, P. Pibarot et al., “Rationale and design of the Transcatheter Aortic Valve Replacement to UNload the Left ventricle in patients with ADvanced heart failure (TAVR UNLOAD) trial,” Am. Heart J., vol. 182, pp. 80–88, 2016. [80] G. C. M. Siontis, P. Overtchouk, T. Cahill, et al., “Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis,” Eur. Heart J., vol. 40, no. 38, pp. 3143–3153, 2019. [81] M. Barbanti, C. Tamburino, P. D'Errigo, et al. “Five-Year Outcomes of Transfemoral Transcatheter Aortic Valve Replacement or Surgical Aortic Valve Replacement in a Real World Population.,” Circ. Cardiovasc. Interv., vol. 12, no. 7, p. e007825, 2019. [82] S. H. Yoon, T. Lefèvre, J. M. Ahn et al., “Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis,” J. Am. Coll. Cardiol., vol. 68, no. 11, pp. 1195–1205, 2016. [83] A. D. Milano, G. Faggian, M. Dodonov et al. “Prognostic value of myocardial fibrosis in patients with severe aortic valve stenosis,” J. Thorac. Cardiovasc. Surg., vol. 144, no. 4, pp. 830–837, 2012. [84] G. Petrov, V. Regitz-Zagrosek, E. Lehmkuhl et al., “Regression of myocardial hypertrophy after aortic valve replacement: faster in women?,” Circulation, vol. 122, no. 11 Suppl, pp. S23-8, 2010. [85] G. Petrov et al., “Maladaptive remodeling is associated with impaired survival in women but not in men after aortic valve replacement,” JACC Cardiovasc. Imaging, vol. 7, no. 11, pp. 1073–1080, 2014. [86] A. Gü Çlü, P. Knaapen, H. J. Harms et al. “Myocardial efficiency is an important determinant of functional improvement after aortic valve replacement in aortic valve stenosis patients: a combined PET and CMR study.” Eur. Heart J. – Cardiovascular Imaging, vol16, pp. 882–889, 2015. [87] R. J. Hicks et al. “Assessment of myocardial oxidative metabolism in aortic valve disease using positron emission tomography with C-11 acetate.,” Am. Heart J., vol. 123, no. 3, pp. 653–64, 1992. [88] J. Schwitter et al. “Myocardial oxygen consumption in aortic valve disease with and without left ventricular dysfunction,” Br Hear. J, vol. 67, pp. 161–9, 1992. [89] H. M. Connolly et al. “Aortic valve replacement for aortic stenosis with severe left ventricular dysfunction. Prognostic indicators.,” Circulation, vol. 95, no. 10, pp. 2395–400, 1997. [90] H. L. Dauerman et al. “Early Recovery of Left Ventricular Systolic Function After CoreValve Transcatheter Aortic Valve Replacement.,” Circ. Cardiovasc. Interv., vol. 9, no. 6, 2016. [91] C. Tribouilloy et al., “Outcome After Aortic Valve Replacement for Low-Flow/Low-Gradient Aortic Stenosis Without Contractile Reserve on Dobutamine Stress Echocardiography,” J. Am. Coll. Cardiol., vol. 53, no. 20, pp. 1865–1873, 2009. [92] B. Vaquette et al., “Valve replacement in patients with critical aortic stenosis and depressed left ventricular function: Predictors of operative risk, left ventricular function recovery, and long term outcome,” Heart, vol. 91, no. 10, pp. 1324–1329, 2005. [93] D. Cramariuc et al. “Low-Flow Aortic Stenosis in Asymptomatic Patients. Valvular-Arterial Impedance and Systolic Function From the SEAS Substudy,” JACC Cardiovasc. Imaging, vol. 2, no. 4, pp. 390-399, 2009. [94] K. Kusunose et al. “Incremental prognostic value of left ventricular global longitudinal strain in patients with aortic stenosis and preserved ejection fraction,” Circ. Cardiovasc. Imaging, vol. 7, no. 6, pp. 938–945, 2014. [95] S. A. M. Nashef et al. “EuroSCORE II,” Eur. J. Cardio-Thoracic Surg., vol. 41, no. 4, pp. 734–745, 2012. [96] The Society of Thoracic Surgeons. “Risk Calculators | STS.” (Online). Available: https://www.sts.org/resources/risk-calculators. (Accessed: 21-Dec-2017). [97] S. C. Cannegieter, F. R. Rosendaal, and E. Briët. “Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses,” Circulation, vol. 89, no. 2, pp. 635–641, 1994. [98] D. R. Johnston et al. “Long-term durability of bioprosthetic aortic valves: Implications from 12,569 implants,” Ann. Thorac. Surg., vol. 99, no. 4, pp. 1239–1247, 2015. [99] N. Glaser, V. Jackson, M. J. Holzmann, A. Franco-Cereceda, and U. Sartipy, “Prosthetic Valve Endocarditis After Surgical Aortic Valve Replacement.,” Circulation, vol. 136, no. 3, pp. 329–331, 2017. [100] P. A. Pellikka, R. A. Nishimura, K. R. Bailey, and A. J. Tajik. “The natural history of adults with asymptomatic, hemodynamically significant aortic stenosis,” J. Am. Coll. Cardiol., vol. 15, no. 5, pp. 1012–1017, 1990. [101] S. C. Malaisrie et al. “Mortality while waiting for aortic valve replacement,” Ann. Thorac. Surg., vol. 98, no. 5, pp. 1564–1571, 2014. [102] R. Rosenhek, T. Binder, G. Porenta et al.“Predictors of outcome in severe, asymptomatic aortic stenosis,” N. Engl. J. Med., vol. 343, no. 9, pp. 611–617, 2000. [103] A. Flores-Marín et al. “Long-Term Predictors of Mortality and Functional Recovery After Aortic Valve Replacement for Severe Aortic Stenosis With Left Ventricular Dysfunction,” Rev. Española Cardiol. (English Ed.) vol. 63, no. 1, pp. 36–45, 2010. [104] J.-L. Monin, J. Quéré, M. Monchi et al. “Low-gradient aortic stenosis: operative risk stratification and predictors for long-term outcome: a multicenter study using dobutamine stress hemodynamics.,” Circulation, vol. 108, no. 3, pp. 319–24, 2003. [105] R. J. Everett, M. A. Clavel, P. Pibarot, and M. R. Dweck, “Timing of intervention in aortic stenosis: A review of current and future strategies,” Heart, vol. 104, no. 24, pp. 2067–2076, Dec. 2018. [106] D. J. Kumbhani. “Randomized Comparison of Early Surgery Versus Conventional Treatment in Very Severe Aortic Stenosis - American College of Cardiology.” (Online). Available: https://www.acc.org/latest-in-cardiology/clinical-trials/2019/11/15/17/34/recovery. (Accessed: 19-Feb-2020). [107] Z. Hachicha, J. G. Dumesnil and P. Pibarot, “Usefulness of the Valvuloarterial Impedance to Predict Adverse Outcome in Asymptomatic Aortic Stenosis,” J. Am. Coll. Cardiol., vol. 54, no. 11, pp. 1003–1011, 2009. [108] S. Sündermann, A. Dademasch, J. Praetorius et al. “Comprehensive assessment of frailty for elderly high-risk patients undergoing cardiac surgery,” Eur. J. Cardio-Thoracic Surg., vol. 39, no. 1, pp. 33–37, 2011. [109] J. Afilalo, M. J. Eisenberg, J. Morin et al. “Gait Speed as an Incremental Predictor of Mortality and Major Morbidity in Elderly Patients Undergoing Cardiac Surgery,” J. Am. Coll. Cardiol., vol. 56, No. 20. pp. 1668–1676, 2010. [110] A. Singh, J. P. Greenwood, C. Berry et al. “Comparison of exercise testing and CMR measured myocardial perfusion reserve for predicting outcome in asymptomatic aortic stenosis: the PRognostic Importance of MIcrovascular Dysfunction in Aortic Stenosis (PRIMID AS) Study,” Eur. Heart J., vol. 38, no. 16, pp. 1222–1229, 2017. [111] A. M. Rafique, S. Biner, I. Ray et al. “Meta-Analysis of Prognostic Value of Stress Testing in Patients With Asymptomatic Severe Aortic Stenosis,” Am. J. Cardiol., vol. 104, no. 7, pp. 972–977, 2009. [112] A. Vahanian, O. Alfieri, F. Andreotti et al. “Guidelines on the management of valvular heart disease (version 2012): The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS),” Eur. Heart J., vol. 33, no. 19, pp. 2451–2496, 2012. [113] C. M. Otto, I. G. Burwash, M. E. Legget et al. “Prospective study of asymptomatic valvular aortic stenosis. Clinical, echocardiographic, and exercise predictors of outcome.,” Circulation, vol. 95, no. 9, pp. 2262–70, 1997. [114] J. M. Paradis et al. “Aortic stenosis and coronary artery disease: What do we know? A comprehensive review of the literature with proposed treatment algorithms,” European Heart Journal, vol. 35, no. 31, 2014. [115] D. Brala, H. I. Michelena, M. E. Sarano et al. “Abstract 16957: Predictive Value of Cardiopulmonary Exercise Testing in Patients With Aortic Stenosis: Comparison With Traditional Echocardiographic Parameters,” Circulation, vol. 128, no. Suppl 22, 2013. [116] P. E. Sigvardsen, L. H. Larsen, H. G. Carstensen et al. “Six-minute walking test and long term prognosis in patients with asymptomatic aortic valve stenosis,” Int. J. Cardiol, vol. 249, pp. 334–339, 2017. [117] D. P. De Arenaza et al. “Preoperative 6-minute walk test adds prognostic information to Euroscore in patients undergoing aortic valve replacement,” Heart, vol. 96, no. 2, pp. 113–117, Jan. 2010. [118] O. Abdul-Jawad Altisent et al. “Predictors and Association With Clinical Outcomes of the Changes in Exercise Capacity After Transcatheter Aortic Valve Replacement,” Circulation, vol. 136, no. 7, pp. 632–643, 2017. [119] J. Petersen, E. Vettorazzi, L. Winter, et al. “Physical and mental recovery after conventional aortic valve surgery,” The Journal of Thoracic and Cardiovascular Surgery, Vol 152, No. 6 pp. 1549 1556.e2, 2016. [120] S. C. Mukhopadhyay, “Wearable Sensors for Human Activity Monitoring: A Review,” IEEE Sens. J., vol. 15, no. 3, pp. 1321–1330, 2015. [121] E. Chiauzzi, C. Rodarte, and P. DasMahapatra. “Patient-centered activity monitoring in the self-management of chronic health conditions.,” BMC Med., vol. 13, p. 77, 2015. [122] D. M. Sherrill, M. L. Moy, J. J. Reilly, and P. Bonato, “Using hierarchical clustering methods to classify motor activities of COPD patients from wearable sensor data.,” J. Neuroeng. Rehabil., vol. 2, no. 1, p. 16, 2005. [123] N. A. Fini, A. E. Holland, J. Keating et al. “How is physical activity monitored in people following stroke?,” Disabil. Rehabil., vol. 37, no. 19, pp. 1717–1731, 2015. [124] P. Castillejo, J.-F. Martinez, J. Rodriguez-Molina, and A. Cuerva, “Integration of wearable devices in a wireless sensor network for an E-health application,” IEEE Wirel. Commun., vol. 20, no. 4, pp. 38–49, 2013. [125] P. Green, A. E. Woglom, P. Genereux et al. “Gait Speed and Dependence in Activities of Daily Living in Older Adults With Severe Aortic Stenosis,” Clin. Cardiol., vol. 35, no. 5, pp. 307–314, 2012. [126] P. A. Toogood, M. P. Abdel, J. A. Spear et al. “The monitoring of activity at home after total hip arthroplasty,” Bone Joint J., vol. 98-B, no. 11, pp. 1450–1454, 2016. [127] A. J. Manson, P. Brown, J. D. O’Sullivan et al. “An ambulatory dyskinesia monitor.,” J. Neurol. Neurosurg. Psychiatry, vol. 68, no. 2, pp. 196–201, 2000. [128] G. Uswatte, W. L. Foo, H. Olmstead et al. “Ambulatory monitoring of arm movement using accelerometry: an objective measure of upper-extremity rehabilitation in persons with chronic stroke.,” Arch. Phys. Med. Rehabil., vol. 86, no. 7, pp. 1498–501, 2005. [129] M. W. A. van Geldorp, H. J. Heuvelman, A. P. Kappetein et al., “Quality of life among patients with severe aortic stenosis,” Netherlands Hear. J., vol. 21, no. 1, pp. 21–27, 2013. [130] National Institute of Biomedical Imaging and Bioengineering. \"Basics of modelling what it is -Computational Modeling” (Online). Available: https://www.nibib.nih.gov/science-education/science-topics/computational-modeling. (Accessed: 23-Nov-2017). [131] A. Garny, D. Noble, and P. Kohl, “Dimensionality in cardiac modelling,” Prog. Biophys. Mol. Biol. vol. 87, no. 1, pp. 47–66, 2005. [132] Y. Shi, P. Lawford, and R. Hose, “Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System,” Biomed. Eng. Online, vol. 10, no. 1, p. 33, 2011. [133] H. Mohammadi and K. Mequanint, “Prosthetic aortic heart valves: Modeling and design,” Med. Eng. Phys., vol. 33, no. 2, pp. 131–147, 2011. [134] S. Tu, E. Barbato, Z. Köszegi et al. “Fractional Flow Reserve Calculation From 3-Dimensional Quantitative Coronary Angiography and TIMI Frame Count,” JACC Cardiovasc. Interv., vol. 7, no. 7, pp. 768–777, 2014. [135] B. T. Tang, S. S. Pickard, F. P. Chan, et al. “Wall Shear Stress is Decreased in the Pulmonary Arteries of Patients with Pulmonary Arterial Hypertension: An Image-Based, Computational Fluid Dynamics Study,” Pulm. Circ., vol. 2, no. 4, pp. 470–476, 2012. [136] P. D. Morris, A. Narracott, H. von Tengg-Kobligk et al. “Computational fluid dynamics modelling in cardiovascular medicine,” Heart, vol. 102, no. 1, pp. 18–28, 2016. [137] NICE. “HeartFlow FFRCT for estimating fractional flow reserve from coronary CT angiography\" (Online) Medical technologies guidance [MTG32]. 2017. Available: https://www.nice.org.uk/guidance/mtg32 (Accessed: 04-06-2019). [138] P. A. L. Tonino, B. De Bruyne, N. H. J. Pijls et al. “Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention,” N. Engl. J. Med., vol. 360, no. 3, pp. 213–224, 2009. [139] D. Noble, A. Garny, and P. J. Noble. “How the Hodgkin-Huxley equations inspired the Cardiac Physiome Project,” J. Physiol., vol. 590, no. 11, pp. 2613–2628, 2012. [140] N. A. Trayanova. “Whole-Heart Modeling Applications to Cardiac Electrophysiology and Electromechanics,” Circ Res.Circ Res.Circ Res, vol. 108, pp. 70–8485, 2011. [141] G. Biglino, C. Capelli, J. Bruse et al. “Computational modelling for congenital heart disease: how far are we from clinical translation?” Heart, vol. 103, pp. 98-103, 2017. [142] L. Itu, P. Sharma, K. F. Ralovich et al. “Non-Invasive Hemodynamic Assessment of Aortic Coarctation: Validation with In Vivo Measurements,” Annals of Biomedical Engineering, vol. 41, no. 4, April pp. 669–681, 2013. [143] M. A. Quail and A. M. Taylor. “Computer Modeling to Tailor Therapy for Congenital Heart Disease.” Curr Cardiol Rep, 15, pp. 395, 2013. [144] B. Su, L. Zhong, X. Wang et al. “Numerical simulation of patient-specific left ventricular model with both mitral and aortic valves by FSI approach,” Comput. Methods Programs Biomed., vol. 113, no. 2, pp. 474–482, 2014. [145] R. Gorlin and S. G. Gorlin. “Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I,” Am. Heart J., vol. 41, no. 1, pp. 1–29, 1951. [146] K. Sagawa, R. K. Lie, and J. Schaefer. “Translation of Otto Frank’s paper, Zeitschrift für Biologie\" 37: 483-526 (1899),” J. Mol. Cell. Cardiol., vol. 22, no. 3, pp. 253–4, 1990. [147] C. M. Lloyd, J. R. Lawson, P. J. Hunter, and P. F. Nielsen. “The CellML Model Repository,” Bioinformatics, vol. 24, no. 18, pp. 2122–2123, 2008. [148] N. Westerhof, G. Elzinga, and P. Sipkema. “An artificial arterial system for pumping hearts,” J. Appl. Physiol., vol. 31, no. 5, pp. 776–81, 1971. [149] H. M. Spotnitz. “Macro design, structure, and mechanics of the left ventricle,” J. Thorac. Cardiovasc. Surg., vol. 119, no. 5, pp. 1053–1077, 2000. [150] T. O’Hara, L. Virág, A. Varró, and Y. Rudy. “Simulation of the Undiseased Human Cardiac Ventricular Action Potential: Model Formulation and Experimental Validation,” PLoS Comput. Biol., vol. 7, no. 5, p. e1002061, 2011. [151] C. A. Taylor and C. A. Figueroa. “Patient-Specific Modeling of Cardiovascular Mechanics,” Annu. Rev. Biomed. Eng. 11, pp. 109–34. 2009. [152] M. S. Vieira, T. Hussain, and C. A. Figueroa. “Patient-Specific Image-Based Computational Modeling in Congenital Heart Disease: A Clinician Perspective,” J. Cardiol. Ther., vol. 2, no. 6, pp. 436–448, 2015. [153] S. F. C. Stewart, P. Hariharan, E. G. Paterson et al. “Results of FDA’s First Interlaboratory Computational Study of a Nozzle with a Sudden Contraction and Conical Diffuser,” Cardiovasc. Eng. Technol., vol. 4, no. 4, pp. 374–391, 2013. [154] J. R. Cebral, M. A. Castro, S. Appanaboyina et al. “Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity.,” IEEE Trans. Med. Imaging, vol. 24, no. 4, pp. 457–67, 2005. [155] C.A. Taylor. “Method and system for image processing to determine patient-specific blood flow characteristics,” HeartFlow Inc. US Patent US20160113528A1. 2015. [156] C. E. Hann, J. G. Chase, T. Desaive et al. “Unique parameter identification for cardiac diagnosis in critical care using minimal data sets,” Comput. Methods Programs Biomed., vol. 99, pp. 75–87. 2010. [157] S. Walton, O. Hassan, and K. Morgan. “Reduced order modelling for unsteady fluid flow using proper orthogonal decomposition and radial basis functions,” Appl. Math. Model., vol. 37, no. 20–21, pp. 8930–8945, 2013. [158] C. E. Hann, J. Revie, D. Stevenson et al. “Patient Specific Identification of the Cardiac Driver Function in a Cardiovascular System Model.” Computer Methods and Programs in Biomedicine, Vol. 101. No. 2. pp. 201-207, 2011. [159] K. B. Chandran and H. Kim. “Computational Mitral Valve Evaluation and Potential Clinical Applications,” Ann. Biomed. Eng., vol. 43, no. 6, pp. 1348–1362, 2015. [160] A. G. Brown, Y. Shi, A. Arndt, et al. “Importance of realistic LVAD profiles for assisted aortic simulations: evaluation of optimal outflow anastomosis locations,” Comput. Methods Biomech. Biomed. Engin., vol. 15, no. 6, pp. 669–680, 2012. [161] K. Sughimoto, F. Liang, Y. Takahara et al. “Assessment of cardiovascular function by combining clinical data with a computational model of the cardiovascular system,” J. Thorac. Cardiovasc. Surg., vol. 145, pp. 1367–1372, 2013. [162] T. A. Quinn and P. Kohl. “Combining wet and dry research: experience with model development for cardiac mechano-electric structure-function studies,” Cardiovasc. Res., vol. 97, no. 4, pp. 601–611, 2013. [163] S. A. Niederer and N. P. Smith, “At the heart of computational modelling.,” J. Physiol., vol. 590, no. 6, pp. 1331–8, 2012. [164] D. Houle, D. R. Govindaraju, and S. Omholt. “Phenomics: the next challenge,” Nat. Rev. Genet., vol. 11, no. 12, pp. 855–866, 2010. [165] P. Segers, E. R. Rietzschel, M. L. De Buyzere et al., “Three- and four-element Windkessel models: Assessment of their fitting performance in a large cohort of healthy middle-aged individuals,” Proc. Inst. Mech. Eng. Part H J. Eng. Med., vol. 222, no. 4, pp. 417–428, 2008. [166] J. K. Li, J. Y. Zhu, and M. Nanna. “Computer modeling of the effects of aortic valve stenosis and arterial system afterload on left ventricular hypertrophy.,” Comput. Biol. Med., vol. 27, no. 6, pp. 477–85, 1997. [167] B. W. Smith, J. G. Chase, R. I. Nokes, et al. “Minimal haemodynamic system model including ventricular interaction and valve dynamics,” Med. Eng. Phys., vol. 26, no. 2, pp. 131–139, 2004. [168] D. Garcia, P. J. C. Barenbrug, P. Pibarot et al. “A ventricular-vascular coupling model in presence of aortic stenosis,” Am. J. Physiol. Heart Circ. Physiol., vol. 288, no. 4, pp. H1874-84, 2005. [169] K. Sagawa, H. Suga, A. A. Shoukas, and K. M. Bakalar. “End-systolic pressure/volume ratio: A new index of ventricular contractility,” Am. J. Cardiol., vol. 40, no. 5, pp. 748–753, 1977. [170] K. Sagawa. “The end-systolic pressure-volume relation of the ventricle: Definition, modifications and clinical use,” Circulation, vol. 63, no. 6 I. pp. 1223–1227, 1981. [171] D. Burkhoff. “Pressure-volume loops in clinical research,” Journal of the American College of Cardiology, vol. 62, no. 13. Elsevier USA, pp. 1173–1176, 2013. [172] B. Ky, B. French, A. May Khan et al. “Ventricular-arterial coupling, remodeling, and prognosis in chronic heart failure,” J. Am. Coll. Cardiol., vol. 62, no. 13, pp. 1165–1172, 2013. [173] F. Seemann, P. Arvidsson, D. Nordlund, et al. “Noninvasive Quantification of Pressure-Volume Loops From Brachial Pressure and Cardiovascular Magnetic Resonance,” Circ. Cardiovasc. Imaging, vol. 12, no. 1, p. e008493, 2019. [174] P. Steendijk. “Pressure-volume measurements by conductance catheter during cardiac resynchronization therapy,” Eur. Hear. J. Suppl., vol. 6, pp. D35–D42, 2004. [175] J. Baan, T. Van Der Velde, H. G. De Bruin et al. “Continuous measurement of left ventricular volume in animals and humans by conductance catheter.” Circulation vol. 70, no. 5, pp. 812-823, 1984. [176] D. Georgakopoulos, W. A. Mitzner, C. Chen-Huan et al., “In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry,” Am. J. Physiol., vol. 274, no. 4 PART2, 1998. [177] American Heart Association. “Heart Valve Surgery Recovery and Follow Up,” 2016. (Online). Available: http://www.heart.org/HEARTORG/Conditions/More/HeartValveProblemsandDisease/Heart-Valve-Surgery-Recovery-and-Follow-Up_UCM_450700_Article.jsp#.Wvg2tmgvyUk. (Accessed: 13-May-2018). [178] European Commission Directorate General for Communications Networks, \"EurValve Deliverable 4.1: Digital Patient Definition.” Horizon 2020, PHC-30-2015, 689617,Research and Innovation Action, 2016. (Online). Available: https://cordis.europa.eu/project/id/689617/results. (Accessed: 04-06-2019). [179] New York Heart Association. “The Criteria Committee for the New York Heart Association. Nomenclature and Criteria for Diagnosis of Diseases of the Heart and Great Vessels.,” Little, Brown Co., Boston, MA, USA, no. 9th ed., pp. 253–255, 1994. [180] J. Eldridge and D. Richley. “Clinical Guidelines by Consensus Recording a standard 12-lead electrocardiogram,” Society for Cardiological Science & Technology (SCST). v2, pp1-26, 2014. [181] R. Wheeler, R. Steeds, B. Rana et al. “A minimum dataset for a standard transoesophageal echocardiogram: A guideline protocol from the British Society of Echocardiography,” Echo Research and Practice, vol. 2, no. 4, pp. G29–G45, 015. [182] T. H. Solutions, “TrialConnect.” [Online]. 2019. Available: https://dhzb.trialconnect.de/home. [Accessed: 19-Dec-2019]. [183] D. Pennell, U. P. Sechtem, C. B. Higgins et al. “Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?,” Eur. Heart J., vol. 25, no. 21, pp. 1940–1965, 2004. [184] R. Lorenz, J. Bock, J. Snyder et al. “Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC-MRI data,” Magnetic Resonance in Medicine, vol. 72, no. 1., pp. 33–40, 2014. [185] M. E. MacDonald, N. D. Forkert, G. B. Pike, and R. Frayne. “Phase error correction in time-averaged 3D phase contrast magnetic resonance imaging of the cerebral vasculature,” PLoS One, vol. 11, no. 2, 2016. [186] D. C. Ghiglia and M. D. Pritt, Two-dimensional phase unwrapping : theory, algorithms, and software. Wiley, New Jersey, USA. 1998. [187] K. S. Nayak, J. F. Nielsen, M. A. Bernstein et al. “Cardiovascular magnetic resonance phase contrast imaging,” Journal of Cardiovascular Magnetic Resonance, vol. 17, no. 1, 2015. [188] N. Stergiopulos, J.-J. Meister, and N. Westerhof. “Determinants of stroke volume and systolic and diastolic aortic pressure,” Am. J. Physio, vol 270, no. 39, pp. H2050-H2059, 1996. [189] J. P. Mynard, M. R. Davidson, D. J. Penny, and J. J. Smolich, “A simple, versatile valve model for use in lumped parameter and one-dimensional cardiovascular models,” Int. j. numer. method. biomed. eng., vol. 28, no. 6–7, pp. 626–641, 2012. [190] P. D. Chantler, E. G. Lakatta, and S. S. Najjar, “Arterial-ventricular coupling: Mechanistic insights into cardiovascular performance at rest and during exercise,” Journal of Applied Physiology, vol. 105, no. 4. American Physiological Society, pp. 1342–1351, 2008. [191] T. Bombardini, L. A. Mulieri, S. Salvadori et al., “Pressure-volume Relationship in the Stress-echocardiography Laboratory: Does (Left Ventricular End-diastolic) Size Matter?,” Rev Esp Cardiol, vol. 70, no. 2, pp. 96–104, 2017. [192] M. Hoeijmakers, M. Rochette, M. Kasztelnik. et al “Real-Time Patient-Specific Transaortic Pressure Gradient Computation from Parameterized Aortic Valve Geometries .” 8th World Congress of Biomechanics, Dublin, 2018. [193] S. F. Nagueh, K. J. Middleton, H. A. Kopelen, et al. “Doppler tissue imaging: a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures,” J. Am. Coll. Cardiol., vol. 30, no. 6, pp. 1527–33, 1997. [194] G. Wharton, R. Steeds, J. Allen et al. “A minimum dataset for a standard adult transthoracic echocardiogram: A guideline protocol from the British Society of echocardiography,” Echo Research and Practice, vol. 2, no. 1. BioScientifica Ltd., pp. G9–G24, 2015. [195] P. M. Heerdt, S. Korfhagen, H. Ezz, and C. Oromendia. “Accuracy of a Simulation Algorithm for Modelling LV Contractility, Diastolic Capacitance, and Energetics Using Data Available From Common Hemodynamic Monitors and Echocardiography,” J. Cardiothorac. Vasc. Anesth., vol. 32, no. 1, pp. 381–388, 2018. [196] H. Asanoi, S. Sasayama, and T. Kameyama, “Ventriculoarterial coupling in normal and failing heart in humans,” Circ. Res., vol. 65, no. 2, pp. 483–493, 1989. [197] J. Pope, R. McConville, M. Kozlowski et al., “SPHERE in a Box: Practical and Scalable EurValve Activity Monitoring Smart Home Kit,” 2017 IEEE 42nd Conference on Local Computer Networks Workshops, LCN Workshops, pp. 128–135, 2017. [198] J. Hendrikx, L. S. Ruijs, L. G. Cox, P. M. Lemmens et al. “Clinical Evaluation of the Measurement Performance of the Philips Health Watch: A Within-Person Comparative Study.,” JMIR mHealth uHealth, vol. 5, no. 2, p. e10, 2017. [199] P. Chodór, K. Wilczek, T. Zielińska et al., “Assessment of cardiovascular function following transcatheter aortic valve implantation based on six-minute walk test,” Cardiol. J., vol. 24, no. 2, pp. 167–175, 2017. [200] B. Iung. “Quality of life after transcatheter aortic valve implantation: the need for more a complete appraisal,” Eur. Hear. J. - Qual. Care Clin. Outcomes, vol. 2, no. 3, pp. 147–148, 2016. [201] R. O. Crapo, R. Casaburi, A. L. Coates et al. “ATS statement: Guidelines for the six-minute walk test,” American Journal of Respiratory and Critical Care Medicine, vol. 166, no. 1. American Lung Association, pp. 111–117, 2002. [202] Thamhain Hans. “Accelerating product developments via phase-gate processes,”, Project Management Institute Annual Seminars & Symposium, Houston, Texas 2000. [203] D. Riebe, J. K. Ehrman, G. Liguori, and M. Magal , ACSM’s guidelines for exercise testing and prescription, Tenth Edition. American College of Sports Medicine. Wolters Kluwer, Baltimore, Maryland, 2017. [204] P. L. Enright and D. L. Sherrill. “Reference equations for the six-minute walk in healthy adults,” Am. J. Respir. Crit. Care Med., vol. 158, no. 5 PART I, pp. 1384–1387, 1998. [205] P. L. Enright, M. A. McBurnie, V. Bittner et al. “The 6-min walk test: A quick measure of functional status in elderly adults,” Chest, vol. 123, no. 2, pp. 387–3982003. [206] P. L. Enright. “The six-minute walk test,” Respiratory Care, vol. 48, no. 8, pp. 783–785, 2003. [207] C. Holmes and N. Briffa. “Patient-Reported Outcome Measures (PROMS) in patients undergoing heart valve surgery: why should we measure them and which instruments should we use?,” Open Hear., vol. 3, no. 1, p. e000315, 2016. [208] L. Shan, A. Saxena, R. Mcmahon, el al. “A systematic review on the quality of life benefits after aortic valve replacement in the elderly,” J. Thorac. Cardiovasc. Surg., vol. 145, pp. 1173–1189, 2013. [209] A. Bilbao, A. Escobar, L. García-Perez et al. “The Minnesota living with heart failure questionnaire: comparison of different factor structures.,” Health Qual. Life Outcomes, vol. 14, p. 23, 2016. [210] World Health Organization. \"WHOQOL-BREF, Field Trial Version\", WHO Programme On Mental Health, Geneva, pp 17-18 1996. [211] A. Kaladji, A. Lucas, G. Kervio, et al. “Sizing for Endovascular Aneurysm Repair: Clinical Evaluation of a New Automated Three-Dimensional Software,” Ann. Vasc. Surg., vol. 24, no. 7, pp. 912–920, 2010. [212] H. Feuillâtre, V. Auffret, M. Castro, et al. “Study of similarity measures for case-based reasoning in transcatheter aortic valve implantation,” Computing in Cardiology, vol. 44, pp. 1–4, 2017. [213] J. M. LeBreton and J. L. Senter. “Answers to 20 Questions About Interrater Reliability and Interrater Agreement,” Organ. Res. Methods, vol. 11, no. 4, pp. 815–852, 2008. [214] M. Handke, G. Heinrichs, F. Beyersdorf, et al.“In vivo analysis of aortic valve dynamics by transesophageal 3-dimensional echocardiography with high temporal resolution,” J. Thorac. Cardiovasc. Surg., vol. 125, no. 6, pp. 1412–1419, 2003. [215] G. Borg. Physical performance and perceived exertion. Lund, Copenhagen: Berlingska boktryckeriet, C. W. K. Gleerup. 1962. [216] European Commission Directorate General for Communications Networks, \" EurValve Deliverable 4.6: Activity Monitoring.” Horizon 2020, PHC-30-2015, 689617,Research and Innovation Action, 2018. (Online). Available: https://cordis.europa.eu/project/id/689617/results. (Accessed: 04-06-2019). [217] J. S. Dahl, A. Brandes, M. K. Poulsen, et al. “Atrial fibrillation in severe aortic valve stenosis - Association with left ventricular left atrial remodeling,” IJC Hear. Vessel., vol. 4, no. 1, pp. 102–107, 2014. [218] M. Rigolli, S. Anandabaskaran, J. P. Christiansen, and G. A. Whalley. “Bias associated with left ventricular quantification by multimodality imaging: a systematic review and meta-analysis,” Open Hear., vol. 3, no. 1, p. e000388, 2016. [219] A. D’Andrea, F. Ferrara, R. Cocchia et al. “Reference ranges and physiologic variations of left E/e’ ratio in healthy adults: Clinical and echocardiographic correlates,” J. Cardiovasc. Echogr., vol. 28, no. 2, pp. 101–108, 2018. [220] B. Villari, G. Vassaili, E. S. Monrad et al. “Normalization of diastolic dysfunction in aortic stenosis late after valve replacement,” Circulation, vol. 91, no. 9, pp. 2353–2358, 1995. [221] P. Gjertsson, K. Caidahl, and O. Bech-Hanssen. “Left ventricular diastolic dysfunction late after aortic valve replacement in patients with aortic stenosis,” Am. J. Cardiol., vol. 96, no. 5, pp. 722–727, 2005. [222] W. Ma, W. Zhang, W. Shi, Y. Kong, and X. Ma. “Left Ventricular Diastolic Function After Aortic Valve Replacement for Chronic Aortic Regurgitation,” Ann. Thorac. Surg., vol. 106, pp24–9, 2018. [223] M. Dalsgaard, J. Kjaergaard, R. Pecini et al. “Left Ventricular Filling Pressure Estimation at Rest and During Exercise in Patients With Severe Aortic Valve Stenosis: Comparison of Echocardiographic and Invasive Measurements,” J. Am. Soc. Echocardiogr., vol. 22, no. 4, pp. 343–349, 2009. [224] J. Greupner, E. Zimmermann, A. Grohmann et al., “Head-to-Head Comparison of Left Ventricular Function Assessment with 64-Row Computed Tomography, Biplane Left Cineventriculography, and Both 2- and 3-Dimensional Transthoracic Echocardiography: Comparison With Magnetic Resonance Imaging as the Reference Standard,” J. Am. Coll. Cardiol., vol. 59, no. 21, pp. 1897–1907, 2012. [225] E. Villa et al. “Factors affecting left ventricular remodeling after valve replacement for aortic stenosis. An overview,” Cardiovascular Ultrasound, vol. 4. BioMed Central, p. 25, 2006. [226] A. Ali, A. Patel, Z. Ali, et al. “Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival,” J. Thorac. Cardiovasc. Surg., vol. 142, no. 2, pp. 285–291, 2011. [227] M. Natsuaki, T. Itoh, S. Tomita, and K. Naito, “Reversibility of cardiac dysfunction after valve replacement in elderly patients with severe aortic stenosis.,” Ann. Thorac. Surg., vol. 65, no. 6, pp. 1634–8, 1998. [228] H. P. Beyerbacht, H.J Lamb, A. Van Der Laarse, et al. “Aortic valve replacement in patients with aortic valve stenosis improves myocardial metabolism and diastolic function,” Radiology, vol. 219, no. 3, pp. 637–643, 2001. [229] M. Gaudino, F. Alessandrini, F. Glieca, et al, “Survival after aortic valve replacement for aortic stenosis: does left ventricular mass regression have a clinical correlate?,” Eur. Heart J., vol. 26, no. 1, pp. 51–7, 2005. [230] R. S. Szwarc, D. Laurent, P. R. Allegrini, and H. A. Ball. “Conductance catheter measurement of left ventricular volume: Evidence for nonlinearity within cardiac cycle,” Am. J. Physiol. - Hear. Circ. Physiol., vol. 268, no. 4 37-4, 1995. [231] C. S. Hayward, W. V. Kalnins, and R. P. Kelly. “Gender-related differences in left ventricular chamber function,” Cardiovasc. Res., vol. 49, no. 2, pp. 340–350, 2001. [232] G. S. Ribeiro, R. D. Melo, L. F. Deresz, et al. “European Society of Cardiology: Cardiac rehabilitation programme after transcatheter aortic valve implantation versus surgical aortic valve replacement: Systematic review and meta-analysis.” European Journal of Preventive Cardiology, vol. 24, no. 7, pp. 688–697, 2017. [233] N. Straiton, K. Jin, R. Bhindi, and R. Gallagher, “Functional capacity and health-related quality of life outcomes post transcatheter aortic valve replacement: a systematic review and meta-analysis.,” Age Ageing, vol. 47, no. 3, pp. 478–482, 2018. [234] P. Green, A. Kirtane, P. Genereux et al., “The Impact Of Six–Minute Walk Test Performance On Outcomes After Transcatheter Aortic Valve Replacement: Insights From The Partner Trial,” J. Am. Coll. Cardiol., vol. 61, no. 10, pp. E1971, 2013. [235] O. Abdul-Jawad Altisent et al. “Predictors and Association With Clinical Outcomes of the Changes in Exercise Capacity After Transcatheter Aortic Valve Replacement.,” Circulation, vol. 136, no. 7, pp. 632–643, 2017. [236] C. A. Kim, S. P. Rasania, J. Afilalo, et al. “Functional Status and Quality of Life After Transcatheter Aortic Valve Replacement,” Ann. Intern. Med., vol. 160, no. 4, p. 243, 2014. [237] H. Baumgartner, J. Hung, J. Bermejo et al. “Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European Association of Cardiovascular Imaging and the American Society of Echocardiography,” Eur. Hear. J. - Cardiovasc. Imaging, vol. 18, no. 3, pp. 254–275, 2017. [238] H. Baumgartner, T. Stefenelli, J. Niederberger, et al. “‘Overestimation’ of catheter gradients by Doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery.,” J. Am. Coll. Cardiol., vol. 33, no. 6, pp. 1655–61, 1999. [239] A. E. Abbas and P. Pibarot. “Hemodynamic characterization of aortic stenosis states,” Catheter. Cardiovasc. Interv., vol. 93, no. 5, pp. 1002–1023, 2019. [240] E. Y. L. Lui, A. H. Steinman, R. S. C. Cobbold, and K. W. Johnston. “Human factors as a source of error in peak Doppler velocity measurement,” J. Vasc. Surg., vol. 42, no. 5, pp. 972.e1-972.e10, 2005. [241] M. Kanski et al. “Whole-heart four-dimensional flow can be acquired with preserved quality without respiratory gating, facilitating clinical use: a head-to-head comparison,” BMC Med. Imaging, vol. 15, no. 1, p. 20, 2015. [242] P. Garg, S. Crandon, P. P. Swoboda et al. “Left ventricular blood flow kinetic energy after myocardial infarction - Insights from 4D flow cardiovascular magnetic resonance,” J. Cardiovasc. Magn. Reson., vol. 20, no. 1, p. 61, Aug. 2018. [243] P. Garg, R. J. van der Geest, P. P. Swoboda et al., “Left ventricular thrombus formation in myocardial infarction is associated with altered left ventricular blood flow energetics.,” Eur. Heart J. Cardiovasc. Imaging, vol. 20, no. 1, pp. 108–117, 2019. [244] S. Crandon, J. J. M. Westenberg, P. P. Swoboda et al. “Impact of Age and Diastolic Function on Novel, 4D flow CMR Biomarkers of Left Ventricular Blood Flow Kinetic Energy,” Sci. Rep., vol. 8, no. 1, p. 14436, 2018. [245] M. Briand et al. “Reduced systemic arterial compliance impacts significantly on left ventricular afterload and function in aortic stenosis: Implications for diagnosis and treatment,” J. Am. Coll. Cardiol., vol. 46, no. 2, pp. 291–298, 2005. [246] F. Antonini-Canterin, G. Huang, E. Cervesato et al. “Symptomatic aortic stenosis: Does systemic hypertension play an additional role?,” Hypertension, vol. 41, no. 6, pp. 1268–1272, 2003. [247] G. E. Pate, “Association between aortic stenosis and hypertension.” J. Heart Valve Dis., vol. 11, no. 5, pp. 612–4, 2002. [248] S. Bozkurtid. “Mathematical modeling of cardiac function to evaluate clinical cases in adults and children,” 2019. [249] D. A. Kass, R. Beyar, E. Lankford, et al. “Influence of contractile state on curvilinearity of in situ end-systolic pressure-volume relations.,” Circulation, vol. 79, no. 1, pp. 167–78, 1989. [250] D. Burkhoff, S. Sugiura, D. T. Yue, and K. Sagawa, “Contractility-dependent curvilinearity of end-systolic pressure-volume relations.,” Am. J. Physiol., vol. 252, no. 6 Pt 2, pp. H1218-27, 1987. [251] T. Noda, C. P. Cheng, P. P. De Tombe, and W. C. Little, “Curvilinearity of LV end-systolic pressure-volume and dP/dtmax-end-diastolic volume relations.,” Am. J. Physiol., vol. 265, no. 3 Pt 2, pp. H910-7, 1993. [252] E. A. Ten Brinke, R. J. Klautz, H. F. Verwey, et al. “Single-beat estimation of the left ventricular end-systolic pressure-volume relationship in patients with heart failure,” Acta Physiol., vol. 198, no. 1, pp. 37–46, 2010. [253] T. Kind, N. Westerhof, T. J. C. Faes, et al.“Cardiac phase-dependent time normalization reduces load dependence of time-varying elastance,” Am. J. Physiol. - Hear. Circ. Physiol., vol. 296, no. 2, pp. H342-9, 2009. [254] Z. M. Malik and M. Zammert. “Anesthetic goals in patients with valvular heart disease,” in Essential Clinical Anesthesia Review, L. S. Aglio, R. W. Lekowski, and R. D. Urman, Eds. Cambridge: Cambridge University Press, pp. 18–21, 2015 [255] J. S. Dahl, S. Barros-Gomes, L. Videbaek et al. “Early Diastolic Strain Rate in Relation to Systolic and Diastolic Function and Prognosis in Aortic Stenosis,” JACC Cardiovasc. Imaging, vol. 9, pp. 519–528, 2016. [256] E. M. Vollema, T. Sugimoto, M. Shen et al. “Association of left ventricular global longitudinal strain with asymptomatic severe aortic stenosis natural course and prognostic value,” JAMA Cardiol., vol. 3, no. 9, pp. 839–847, 2018. [257] R. Bing, R. J. C. Everett, C. Tuck, et al. “Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial,” Am. Heart J., vol. 212, pp. 91–100, 2019. [258] P. Green, S. Kodali, M. B. Leon, and M. S. Maure. “Echocardiographic assessment of pressure volume relations in heart failure and valvular heart disease: Using imaging to understand physiology,” Minerva Cardioangiologica, vol. 59, no. 4. pp. 375–389, 2011. [259] R. J. Baciie, Y. Wang, and C. R. Jorgensen, “Hemodynamic Effects of Exercise in Isolated Valvular Aortic Stenosis.” Circulation; Volume XLIV, pp. 1003-1013, 1971. [260] R. Bilkhu, M. Jahangiri, and C. M. Otto, “Patient-prosthesis mismatch following aortic valve replacement,” Heart, vol. 105, no. Suppl 2, pp. S28–S33, 2019. [261] S. Ito, W. Miranda, J. Thaden et al. “Impact of Left Ventricular Ejection Fraction Between 50 And 60% Versus ≥60% on Mortality After Aortic Valve Replacement for Severe Aortic Stenosis,” J. Am. Coll. Cardiol., vol. 71, no. 11, p. A1968, 2018. [262] A. Furer, S.Chen, B.Redfors et al. “Effect of Baseline Left Ventricular Ejection Fraction on 2-Year Outcomes After Transcatheter Aortic Valve Replacement: Analysis of the PARTNER 2 Trials.,” Circ. Heart Fail., vol. 12, no. 8, p. e005809, 2019. [263] C. Raphael, C. Briscoe, J. Davies et al. “Limitations of the New York Heart Association functional classification system and self-reported walking distances in chronic heart failure,” Heart, vol. 93, no. 4, pp. 476–482, 2007. [264] E. Spitzer, R. T. Hahn, P. Pibarot et al. “Aortic Stenosis and Heart Failure: Disease Ascertainment and Statistical Considerations for Clinical Trials,” Card. Fail. Rev., vol. 5, no. 2, pp. 99–105, 2019. [265] C. Castaneda, K. Nalley, C. Mannion et al. “Clinical decision support systems for improving diagnostic accuracy and achieving precision medicine,” J. Clin. Bioinforma., vol. 5, no. 1, 2015. [266] R. Kaushal, K. G. Shojania, and D. W. Bates, “Effects of computerized physician order entry and clinical decision support systems on medication safety: A systematic review,” Archives of Internal Medicine, vol. 163, no. 12. pp. 1409–1416, 2003. [267] D. W. Bates, J. M. Teich, J. Lee et al. “The impact of computerized physician order entry on medication error prevention,” J. Am. Med. Informatics Assoc., vol. 6, no. 4, pp. 313–321, 1999. [268] O. Eminaga, M. Abbas, R. Hinkelammert et al. “CMDX©-based single source information system for simplified quality management and clinical research in prostate cancer,” BMC Med. Inform. Decis. Mak., vol. 12, no. 1, p. 141, 2012. [269] D. A. Berry, E. S. Iversen, D. F. Gudbjartsson et al., “BRCAPRO validation, sensitivity of genetic testing of BRCA1/BRCA2, and prevalence of other breast cancer susceptibility genes,” J. Clin. Oncol., vol. 20, no. 11, pp. 2701–2712, 2002. [270] M. W. M. Jaspers, M. Smeulers, H. Vermeulen, and L. W. Peute, “Effects of clinical decision-support systems on practitioner performance and patient outcomes: A synthesis of high-quality systematic review findings,” J. Am. Med. Informatics Assoc., vol. 18, no. 3, pp. 327–334, 2011. [271] T. J. Bright, A. Wong, R. Dhurjati et al., “Effect of clinical decision-support systems: A systematic review,” Annals of Internal Medicine, vol. 157, no. 1. American College of Physicians, pp. 29–43, 2012. [272] J. Petersen, E. Vettorazzi, L. Winter et al. “Physical and mental recovery after conventional aortic valve surgery,” J. Thorac. Cardiovasc. Surg., vol. 152, no. 6, pp. 1549-1556.e2, 2016. [273] GE Healthcare “CARESCAPE V100 Vital Signs Monitor .” (Online) CARESCAPE V100 SpecificationDOC0385787 rev7 4/2020. Available: https://www.vingmed.dk/wp-content/uploads/sites/3/2020/06/CARESCAPE-V100-Spec-Sheet_DOC0385787-rev7.pdf (Accessed: 05-05-20). [274] W. G. O’Dell. “Accuracy of Left Ventricular Cavity Volume and Ejection Fraction for Conventional Estimation Methods and 3D Surface Fitting.,” J. Am. Heart Assoc., vol. 8, no. 6, p. e009124, 2019. [275] W. Kroon, M. Bosboom, W. Huberts et al. “Computational model for estimating the short- and long-term cardiac response to arteriovenous fistula creation for hemodialysis,” Med. Biol. Eng. Comput., vol. 50, no. 12, pp. 1289–1298, 2012. [276] R. McConville, G. Archer, I. Craddock et al., “Online Heart Rate Prediction using Acceleration from a Wrist Worn Wearable.” KDD Workshop on Machine Learning for Medicine and Healthcare. London, UK. 2018. [277] Z. Keshavarz-Motamed, J. Garcia, E. Gaillard et al. “Non-Invasive Determination of Left Ventricular Workload in Patients with Aortic Stenosis Using Magnetic Resonance Imaging and Doppler Echocardiography,” PLoS One, vol. 9, no. 1, p. e86793, 2014. [278] P. Youssefi, A. Gomez, T. He et al., “Patient-specific computational fluid dynamics—assessment of aortic hemodynamics in a spectrum of aortic valve pathologies,” J. Thorac. Cardiovasc. Surg., vol. 153, no. 1, pp. 8-20.e3, 2017. [279] H. Suga, R. Hisano, Y. Goto, and O. Yamada, “Normalization of end systolic pressure volume relation and emax of different sized hearts,” Jpn. Circ. J., vol. 48, no. 2, pp. 136–143, 1984. [280] D. Burkhoff, I. Mirsky, H. Suga, and D. Burkhoff, “Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers,” Am J Physiol Hear. Circ Physiol, vol. 289, pp. 501–512, 2005. [281] H. Takaoka, G. Esposito, L. Mao, et al. “Heart size-independent analysis of myocardial function in murine pressure overload hypertrophy,” Am. J. Physiol. - Hear. Circ. Physiol., vol. 282, no. 6 51-6, pp. 2190-7, 2002. [282] K. Tobita and B. B. Keller, “End-systolic myocardial stiffness is a load-independent index of contractility in stage 24 chick embryonic heart.,” Am. J. Physiol., vol. 276, no. 6, pp. 2102-8, 1999. [283] Z. Keshavarz-Motamed, J. Garcia, E. Gaillard et al. “Non-Invasive Determination of Left Ventricular Workload in Patients with Aortic Stenosis Using Magnetic Resonance Imaging and Doppler Echocardiography,” PLoS One, vol. 9, no. 1, p. e86793, 2014. [284] C. J. O’Sullivan, E. Spitzer, D. Heg et al. “Effect of resting heart rate on two-year clinical outcomes of high-risk patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation,” EuroIntervention, vol. 12, no. 4, pp. 490–498, 2016. [285] D. Zhang, X. Shen, and X. Qi, “Resting heart rate and all-cause and cardiovascular mortality in the general population: a meta-analysis,” Can. Med. Assoc. J., vol. 188, no. 3, pp. E53–E63, 2016. [286] J. L. Vukasovic, F. Florenzano, P. Adriazola, and E. Escobar. “Heart rate variability in severe aortic stenosis.,” J. Heart Valve Dis., vol. 8, no. 2, pp. 143–8, 1999. [287] J. H. Spühler, J. Jansson, N. Jansson, and J. Hoffman, “3D fluid-structure interaction simulation of aortic valves using a unified continuum ALE FEM model,” Front. Physiol., vol. 9, 2018. [288] M. Enriquez-Sarano and C. Tribouilloy, “Quantitation of mitral regurgitation: Rationale, approach, and interpretation in clinical practice,” Heart, vol. 88, no. suppl. 4., pp. iv1–iv3, 2002. [289] P. A. Grayburn, N. J. Weissman, and J. L. Zamorano. “Quantitation of mitral regurgitation,” Circulation, vol. 126, no. 16. pp. 2005–2017, 2012. [290] F. Helvacioglu, O. Yildirimturk, C. Duran et al. “The evaluation of mitral valve stenosis: comparison of transthoracic echocardiography and cardiac magnetic resonance.,” Eur. Heart J. Cardiovasc. Imaging, vol. 15, no. 2, pp. 164–9, Feb. 2014. [291] D. R. Warriner, M. Bayley, Y. Shi, et al. “Computer model for the cardiovascular system: Development of an e-learning tool for teaching of medical students,” BMC Med. Educ., vol. 17, no. 1, 2017."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.826809"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["H2020 PHC-30–2015, 689617"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/28567/1/Thesis_Final_Submission_G_Archer_04_03_21.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Background Stenosis of the aortic valve causes increased left ventricular pressure leading to adverse clinical outcomes. The selection and timing of intervention (surgical replacement or transcatheter implantation) is often unclear and is based upon limited data. Hypothesis A comprehensive and integrated personalised approach, including recognition of cardiac energetics parameters extracted from a personalised mathematical model, mapped to patient activity, has the potential to improve diagnosis and the planning and timing of interventions. Aims This project seeks to implement a simple, personalised, mathematical model of patients with aortic stenosis (AS), which can ‘measure’ cardiac work and power parameters that provide an effective characterisation of the demand on the heart in both rest and exercise conditions and can predict the changes of these parameters following an intervention. The specific aims of this project are: • to critically review current diagnostic methods • to evaluate the potential role of pre- and post-procedural measured patient activity • to implement a simple, personalised, mathematical model of patients with AS • to evaluate the potential role of a clinical decision support system Methods Twenty-two patients with severe AS according to ESC criteria were recruited. Relevant clinical, imaging, activity monitoring, six-minute walk test, and patient reported data were collected, before and early and after treatment. Novel imaging techniques were developed to help in the diagnosis of AS. A computational model was developed and executed using the data collected to create non-invasive pressure volume loops and study the global haemodynamic burden on the left ventricle. Simulations were run to predict the haemodynamic parameters both during exercise and following intervention. Modelled parameters were validated against clinically measured values. This information was then correlated with symptoms and activity data. A clinical decision support tool was created and populated with data obtained and its clinical utility evaluated. Outcomes The results of this project suggest that the combination of imaging and activity data with computational modelling provides a novel, patient-specific insight into patients’ haemodynamics and may help guide clinical decision making in patients with AS."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Computational Modelling in the Management of Patients with Aortic Valve Stenosis"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gunn, Julian","Briffa, Norman","Hose, Rod"],"dc:contributor.sponsor":["European Comission Horizon 2020"],"dc:creator":["Archer, Gareth Trevor"],"dc:date":["2020-05"],"dc:date.issued":["2020-05"],"dc:description.abstract":["Background Stenosis of the aortic valve causes increased left ventricular pressure leading to adverse clinical outcomes. The selection and timing of intervention (surgical replacement or transcatheter implantation) is often unclear and is based upon limited data. Hypothesis A comprehensive and integrated personalised approach, including recognition of cardiac energetics parameters extracted from a personalised mathematical model, mapped to patient activity, has the potential to improve diagnosis and the planning and timing of interventions. Aims This project seeks to implement a simple, personalised, mathematical model of patients with aortic stenosis (AS), which can ‘measure’ cardiac work and power parameters that provide an effective characterisation of the demand on the heart in both rest and exercise conditions and can predict the changes of these parameters following an intervention. The specific aims of this project are: • to critically review current diagnostic methods • to evaluate the potential role of pre- and post-procedural measured patient activity • to implement a simple, personalised, mathematical model of patients with AS • to evaluate the potential role of a clinical decision support system Methods Twenty-two patients with severe AS according to ESC criteria were recruited. Relevant clinical, imaging, activity monitoring, six-minute walk test, and patient reported data were collected, before and early and after treatment. Novel imaging techniques were developed to help in the diagnosis of AS. A computational model was developed and executed using the data collected to create non-invasive pressure volume loops and study the global haemodynamic burden on the left ventricle. Simulations were run to predict the haemodynamic parameters both during exercise and following intervention. Modelled parameters were validated against clinically measured values. This information was then correlated with symptoms and activity data. A clinical decision support tool was created and populated with data obtained and its clinical utility evaluated. Outcomes The results of this project suggest that the combination of imaging and activity data with computational modelling provides a novel, patient-specific insight into patients’ haemodynamics and may help guide clinical decision making in patients with AS."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.826809"],"dc:identifier.grantnumber":["H2020 PHC-30–2015, 689617"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/28567/1/Thesis_Final_Submission_G_Archer_04_03_21.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Faculty of Health (Sheffield)","Medicine (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/28567/"],"dc:relation.references":["[1] S. J. Choo, G. McRae, J.Olomon et al. “Aortic root geometry: pattern of differences between leaflets and sinuses of Valsalva.,” J. Heart Valve Dis., vol. 8, no. 4, pp. 407–15, 1999. [2] Wikimedia Commons. \"Diagram of the human heart\" (Online). Available: https://commons.wikimedia.org/wiki/File:Diagram_of_the_human_heart.svg (Accessed: 10-Feb-2018). [3] M. J. Thubrikar, S. P. Nolan, J. Aouad, and J. D. Deck. “Stress sharing between the sinus and leaflets of canine aortic valve.,” Ann. Thorac. Surg., vol. 42, no. 4, pp. 434–40, 1986. [4] A. Hamdan, V. Guetta, Konen, Eli et al. “Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: Insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy,” J. Am. Coll. Cardiol., vol. 59, no. 2, pp. 119–127, 2012. [5] M. Misfeld and H. H. Sievers. “Heart valve macro- and microstructure,” Philosophical Transactions of the Royal Society B: Biological Sciences, vol. 362, no. 1484. Royal Society, pp. 1421–1436, 2007. [6] D. A. Watkins, C. Johnson, S. Colquhoun et al. “Global, Regional, and National Burden of Rheumatic Heart Disease, 1990–2015,” N. Engl. J. Med., vol. 377, no. 8, pp. 713–722, 2017. [7] P. G. Supino, J. S. Borer, J. Preibisz, and A. Bornstein, “The Epidemiology of Valvular Heart Disease: a Growing Public Health Problem,” Heart Fail. Clin., vol. 2, no. 4, pp. 379–393, 2006. [8] Heart Valve Voice . “Giving a voice to those with heart valve disease.,” A Heart Valve Voice White Paper. 2014. [9] P. Faggiano, F. Antonini-Canterin, F. Baldessin et al. “Epidemiology and cardiovascular risk factors of aortic stenosis,” Cardiovasc. Ultrasound, vol. 4, 2006. [10] J. L. D’Arcy, S. Coffey, M. A. Loudon et al. “Large-scale community echocardiographic screening reveals a major burden of undiagnosed valvular heart disease in older people: The OxVALVE Population Cohort Study,” Eur. Heart J., vol. 37, no. 47, pp. 3515-3522a, 2016. [11] G. A. Roth, D. Abate, H. Abate et al. “Global, regional, and national age-sex-specific mortality for 282 causes of death in 195 countries and territories, 1980-2017: a systematic analysis for the Global Burden of Disease Study 2017\". Lancet, vol 392, pp.1736–88, 2018. [12] S. N. Vaslef and W. C. Roberts. “Early descriptions of aortic stenosis,” Am. Heart J., vol. 125, pp. 1475–1483, 1993. [13] J. G. Mönckeberg. “Der normale histologische Bau und die Sklerose der Aortenklappen,” Virchows Arch. Pathol. Anat. Physiol. Klin. Med., vol. 176, no. 3, pp. 472–514, 1904. [14] N. M. Rajamannan. “Update on the pathophysiology of aortic stenosis,” Eur. Hear. J. Suppl., vol. 10, no. suppl_E, pp. E4–E10, 2008. [15] T. A. Pawade, D. E. Newby, and M. R. Dweck. “Calcification in aortic stenosis: The skeleton key,” J. Am. Coll. Cardiol., vol. 66, no. 5, pp. 561–577, 2015. [16] M. R. Dweck, N. A. Boon, and D. E. Newby. “Calcific aortic stenosis: A disease of the valve and the myocardium,” J. Am. Coll. Cardiol., vol. 60, no. 19. pp. 1854–1863, 2012. [17] C. M. Otto, J. Kuusisto, D. D. Reichenbach et al. “Characterization of the early lesion of ‘degenerative’ valvular aortic stenosis: Histological and immunohistochemical studies,” Circulation, vol. 90, no. 2, pp. 844–853, 1994. [18] R. A. Nishimura, J. A. Grantham, H. M. Connolly et al. “Low-output, low-gradient aortic stenosis in patients with depressed left ventricular systolic function: the clinical utility of the dobutamine challenge in the catheterization laboratory.,” Circulation, vol. 106, no. 7, pp. 809–13, 2002. [19] I. G. Burwash. “Low-flow, low-gradient aortic stenosis: from evaluation to treatment,” Curr. Opin. Cardiol., vol. 22, no. 2, pp. 84–91, 2007. [20] W. J. Paulus, S. U. Sys, G. R. Heyndrickx, and E. Andries. “Orifice variability of the stenotic aortic valve: Evaluation before and after balloon aortic valvuloplasty,” J. Am. Coll. Cardiol., vol. 17, no. 6, pp. 1263–1269, 1991. [21] C. M. Otto. “Calcific Aortic Stenosis — Time to Look More Closely at the Valve,” N. Engl. J. Med., vol. 359, no. 13, pp. 1395–1398, Sep. 2008. [22] P. Pibarot and J. G. Dumesnil, “Improving assessment of aortic stenosis,” J. Am. Coll. Cardiol., vol 60, no. 3, pp. 169-180, 2012. [23] J. Chambers. “The left ventricle in aortic stenosis: evidence for the use of ACE inhibitors.,” Heart, vol. 92, no. 3, pp. 420–3, Mar. 2006. [24] B. A. Carabello, W. J. Paulus, W. J. Paulus, P. Blase, and A. Carabello, “Aortic stenosis,” Lancet, vol. 373, pp. 956–966, 2009. [25] C. W. L. Chin et al. “Myocardial Fibrosis and Cardiac Decompensation in Aortic Stenosis,” JACC Cardiovasc. Imaging, vol. 10, no. 11, pp. 1320–1333, 2017. [26] J. A. Hill and E. N. Olson. “Cardiac plasticity,” New England Journal of Medicine, vol. 358, no. 13. Massachussetts Medical Society, p. 1370, 2008. [27] R. Ramaraj and V. L. Sorrell. “Degenerative aortic stenosis.,” BMJ, vol. 336, no. 7643, pp. 550–5, 2008. [28] B. A. Carabello, L. H. Green, W. Grossman et al. “Hemodynamic determinants of prognosis of aortic valve replacement in critical aortic stenosis and advanced congestive heart failure.,” Circulation, vol. 62, no. 1, pp. 42–8, 1980. [29] H. Baumgartner et al. “2017 ESC/EACTS Guidelines for the management of valvular heart disease,” Eur. Heart J., vol. 38, no. 36, pp. 2739–2791, 2017. [30] G. P. McCann, C. D. Steadman, S. G. Ray, et al. “Managing the asymptomatic patient with severe aortic stenosis: randomised controlled trials of early surgery are overdue,” Heart, vol. 97, no. 14, pp. 1119–21, 2011. [31] R. A. Nishimura et al. “2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines,” Circulation, vol. 135, no. 25, pp. 1159–1195, 2017. [32] C. M. Otto et al. “Prospective study of asymptomatic valvular aortic stenosis. Clinical, echocardiographic, and exercise predictors of outcome.,” Circulation, vol. 95, no. 9, pp. 2262–70, May 1997. [33] F. Sotiropoulos and I. Borazjani. “A review of state-of-the-art numerical methods for simulating flow through mechanical heart valves,” Med. Biol. Eng. Comput., vol. 47, no. 3, pp. 245–256, 2009. [34] F. Schwarz, P. Baumann, J. Manthey et al. “The effect of aortic valve replacement on survival.,” Circulation, vol. 66, no. 5, pp. 1105–10, Nov. 1982. [35] J. Ross and E. Braunwald, “Aortic stenosis.,” Circulation, vol. 38, no. 1 Suppl, pp. 61–7. 1968. [36] L. Hatle, A. Brubakk, A. Tromsdal, and B. Angelsen. “Noninvasive assessment of pressure drop in mitral stenosis by Doppler ultrasound,” Br. Heart J., vol. 40, pp. 131–140, 1978. [37] A. P. Yoganathan, E. G. Cape, H. W. Sung et al. “Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques.,” J. Am. Coll. Cardiol., vol. 12, no. 5, pp. 1344–53, 1988. [38] F. Donati, S. Myerson, M. M. Bissell et al. “Beyond Bernoulli: Improving the Accuracy and Precision of Noninvasive Estimation of Peak Pressure Drops.,” Circ. Cardiovasc. Imaging, vol. 10, no. 1, p. e005207, 2017. [39] M. A. Clavel, J. Magne, and P. Pibarot. “Low-gradient aortic stenosis,” European Heart Journal, vol. 37, no. 34, pp. 2645–2657, 2016. [40] A.-C. Pouleur, J.-B. le Polain de Waroux, A. Pasquetet al. “Planimetric and continuity equation assessment of aortic valve area: Head to head comparison between cardiac magnetic resonance and echocardiography,” J. Magn. Reson. Imaging, vol. 26, no. 6, pp. 1436–1443, 2007. [41] A. C. Pouleur, J.B. le Polain de Waroux, A. Pasquet et al. “Aortic Valve Area Assessment: Multidetector CT Compared with Cine MR Imaging and Transthoracic and Transesophageal Echocardiography,” Radiology, vol. 244, no. 3, pp. 745–754, 2007. [42] J. Weese, A. Lungu, J. Peters et al. “CFD- and Bernoulli-based pressure drop estimates: A comparison using patient anatomies from heart and aortic valve segmentation of CT images,” Med. Phys., vol. 44, no. 6, pp. 2281–2292, 2017. [43] D. Muraru. “Impact :of 3D Echo on the Assessment of Aortic Stenosis Severity.” (online). Available https://www.escardio.org/static_file/Escardio/education/live-events/courses/imaging/3D-AS-severity-Muraru.pdf (Accessed: 18-Dec-2017). [44] M. R. Dweck, W.Jenkins, A. Vesey et al. “18F-Sodium Fluoride Uptake Is a Marker of Active Calcification and Disease Progression in Patients With Aortic Stenosis,” Circ. Cardiovasc. Imaging, vol. 7, no. 2, pp. 371–378, 2014. [45] M. A. Clavel, P. Pibarot, D. Messika-Zeitoun et al. “Impact of aortic valve calcification, as measured by MDCT, on survival in patients with aortic stenosis: Results of an international registry study,” J. Am. Coll. Cardiol., vol. 64, no. 12, pp. 1202–1213, 2014. [46] S. Plein, J. P. Greenwood, and J. P. Ridgway, Cardiovascular MR manual. Springer, 2011. [47] P. J. Cawley, J. H. Maki, and C. M. Otto, “Cardiovascular magnetic resonance imaging for valvular heart disease. Technique and validation,” Circulation, vol. 119, no. 3, pp. 468–478, 2009. [48] R. J. van der Geest and P. Garg, “Advanced Analysis Techniques for Intra-cardiac Flow Evaluation from 4D Flow MRI,” Current Radiology Reports, vol. 4, no. 7, 2016. [49] I. Valverde, S. Nordmeyer, S. Uribe et al. “Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisition,” J. Cardiovasc. Magn. Reson., vol. 14, no. 1, p. 25, 2012. [50] C. Binter, A. Gotschy, S. Sündermann et al. “Turbulent Kinetic Energy Assessed by Multipoint 4-Dimensional Flow Magnetic Resonance Imaging Provides Additional Information Relative to Echocardiography for the Determination of Aortic Stenosis Severity.,” Circ. Cardiovasc. Imaging, vol. 10, no. 6, p. e005486, 2017. [51] J. Garcia, A. J. Barker, and M. Markl, “The Role of Imaging of Flow Patterns by 4D Flow MRI in Aortic Stenosis,” JACC: Cardiovascular Imaging, vol. 12, no. 2., pp. 252–266, 01-Feb-2019. [52] B. Casas, J. Lantz, P. Dyverfeldt, and T. Ebbers, “4D Flow MRI-Based Pressure Loss Estimation in Stenotic Flows: Evaluation Using Numerical Simulations.” Magnetic Resonance in Medicine, vol. 75: pp. 1808–1821. 2016. [53] B. P. Adriaans, J. Westenberg, Y. Cauteren et al. “Clinical assessment of aortic valve stenosis: Comparison between 4D flow MRI and transthoracic echocardiography,” J. Magn. Reson. Imaging, vol. 51, no. 2, pp. 472–480, 2020. [54] M. Markl, S. Schnell, C. Wu et al. “Advanced flow MRI: emerging techniques and applications,” Clinical Radiology, vol. 71, no. 8., pp. 779–795, 2016. [55] J. Chambers, D. Bach, J. Dumesnil et al. “Crossing the aortic valve in severe aortic stenosis: no longer acceptable?,” J. Heart Valve Dis., vol. 13, no. 3, pp. 344–6, 2004. [56] M. E. Assey, M. R. Zile, B. W. Usher et al. “Effect of catheter positioning on the variability of measured gradient in aortic stenosis,” Cathet. Cardiovasc. Diagn., vol. 30, no. 4, pp. 287–92, 1993. [57] I. Ben-Dor, S. Minha, I. Barbash et al., “Correlation of Brain Natriuretic Peptide Levels in Patients With Severe Aortic Stenosis Undergoing Operative Valve Replacement or Percutaneous Transcatheter Intervention With Clinical, Echocardiographic, and Hemodynamic Factors and Prognosis,” Am. J. Cardiol., vol. 112, no. 4, pp. 574–579, 2013. [58] J. Bergler-Klein, U. Klaar, M. Heger et al. “Natriuretic peptides predict symptom-free survival and postoperative outcome in severe aortic stenosis,” Circulation, vol. 109, no. 19, pp. 2302–2308, 2004. [59] M. A. Clavel, J. Malouf, H. Michelena et al., “B-type natriuretic peptide clinical activation in aortic stenosis: Impact on long-term survival,” J. Am. Coll. Cardiol., vol. 63, no. 19, pp. 2016–2025, 2014. [60] C. W. L. Chin, A. Shah, D. McAllister, et al. “High-sensitivity troponin i concentrations are a marker of an advanced hypertrophic response and adverse outcomes in patients with aortic stenosis,” Eur. Heart J., vol. 35, no. 34, pp. 2312–2321, 2014. [61] G. Soulat, N. Kachenoura,E. Bollache et al., “New estimate of valvuloarterial impedance in aortic valve stenosis: A cardiac magnetic resonance study,” J. Magn. Reson. Imaging, vol. 45, no. 3, pp. 795–803, 2017. [62] S. Maréchaux, A. Ringle, D. Rusinaru et al. “Prognostic Value of Aortic Valve Area by Doppler Echocardiography in Patients With Severe Asymptomatic Aortic Stenosis.,” J. Am. Heart Assoc., vol. 5, no. 5, p. e003146, 2016. [63] L. M. Moura, S. F. Ramos, J Zamorano et al. “Rosuvastatin Affecting Aortic Valve Endothelium to Slow the Progression of Aortic Stenosis,” J. Am. Coll. Cardiol., vol. 49, no. 5, pp. 554–561, 2007. [64] A. B. Rossebo, T. R. Pedersen, K. Boman et al., “Intensive Lipid Lowering with Simvastatin and Ezetimibe in Aortic Stenosis,” N. Engl. J. Med., vol. 359, no. 13, pp. 1343–1356, 2008. [65] A. Hussain, A. Auensen, C. Brunborg et al. “Age-dependent morbidity and mortality outcomes after surgical aortic valve replacement'” Interactive CardioVascular and Thoracic Surgery, vol 27, no. 5, pp. 650–656, 2018. [66] M. Sarkar and V. Prabhu, “Basics of cardiopulmonary bypass,” Indian Journal of Anaesthesia, vol. 61, no. 9. pp. 760–767, 2017. [67] T. Walther, J. Blumenstein, A. Van Linden, and J. Kempfert, “Contemporary management of aortic stenosis: Surgical aortic valve replacement remains the gold standard,” Heart, vol. 98, no. Suppl. 4, pp. iv23–iv29, 01-2012. [68] Cardiac Surgery Audit Data. “SCTS Blue Book Online ” (Online). Available: http://bluebook.scts.org/. (Accessed: 28-Nov-2019). [69] M. A. Borger, V. Moustafine, L. Conradi et al. “A randomized multicenter trial of minimally invasive rapid deployment versus conventional full sternotomy aortic valve replacement,” in Annals of Thoracic Surgery, 2015, vol. 99, no. 1, pp. 17–25. [70] D. Gilmanov, A. Miceli, M. Ferrarini et al. “Aortic valve replacement through right anterior minithoracotomy: can sutureless technology improve clinical outcomes?,” Ann. Thorac. Surg., vol. 98, no. 5, pp. 1585–1592, 2014. [71] R. Chandola, K. Teoh, A. Elhenawy, and G. Christakis, “Perceval Sutureless Valve – are Sutureless Valves Here?,” Curr. Cardiol. Rev., vol. 11, no. 3, pp. 220–228, 2014. [72] T. J. Cahill, M. Chen, K. Hayashida et al. “Transcatheter aortic valve implantation: current status and future perspectives,” Eur. Heart J., vol. 39, no. 28, pp. 2625–2634, Jul. 2018. [73] R. Orlando, M. Pennant, S. Rooney et al. “Cost-effectiveness of transcatheter aortic valve implantation (TAVI) for aortic stenosis in patients who are high risk or contraindicated for surgery: A model-based economic evaluation,” Health Technology Assessment, vol. 17, no. 33. pp. 1–86, 2013. [74] M. B. Leon, C. R. Smith, M. Mack et al. “Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery,” N. Engl. J. Med., vol. 363, no. 17, pp. 1597–1607, 2010. [75] C. R. Smith, M. B. Leon, M. J. Mack et al. “Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients,” N. Engl. J. Med., vol. 364, no. 23, pp. 2187–2198, Jun. 2011. [76] M. J. Reardon et al., “Surgical or transcatheter aortic-valve replacement in intermediate-risk patients,” N. Engl. J. Med., vol. 376, no. 14, pp. 1321–1331, 2017. [77] M. J. Mack, M. B. Leon, V. H. Thourani et al. “Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients,” N. Engl. J. Med., vol. 380, no. 18, pp. 1695–1705, 2019. [78] M. J. Mack, M. B. Leon, C. R. Smith et al., “5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): A randomised controlled trial,” Lancet, vol. 385, no. 9986, pp. 2477–2484, 2015. [79] E. Spitzer, N. M. Van Mieghem, P. Pibarot et al., “Rationale and design of the Transcatheter Aortic Valve Replacement to UNload the Left ventricle in patients with ADvanced heart failure (TAVR UNLOAD) trial,” Am. Heart J., vol. 182, pp. 80–88, 2016. [80] G. C. M. Siontis, P. Overtchouk, T. Cahill, et al., “Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis,” Eur. Heart J., vol. 40, no. 38, pp. 3143–3153, 2019. [81] M. Barbanti, C. Tamburino, P. D'Errigo, et al. “Five-Year Outcomes of Transfemoral Transcatheter Aortic Valve Replacement or Surgical Aortic Valve Replacement in a Real World Population.,” Circ. Cardiovasc. Interv., vol. 12, no. 7, p. e007825, 2019. [82] S. H. Yoon, T. Lefèvre, J. M. Ahn et al., “Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis,” J. Am. Coll. Cardiol., vol. 68, no. 11, pp. 1195–1205, 2016. [83] A. D. Milano, G. Faggian, M. Dodonov et al. “Prognostic value of myocardial fibrosis in patients with severe aortic valve stenosis,” J. Thorac. Cardiovasc. Surg., vol. 144, no. 4, pp. 830–837, 2012. [84] G. Petrov, V. Regitz-Zagrosek, E. Lehmkuhl et al., “Regression of myocardial hypertrophy after aortic valve replacement: faster in women?,” Circulation, vol. 122, no. 11 Suppl, pp. S23-8, 2010. [85] G. Petrov et al., “Maladaptive remodeling is associated with impaired survival in women but not in men after aortic valve replacement,” JACC Cardiovasc. Imaging, vol. 7, no. 11, pp. 1073–1080, 2014. [86] A. Gü Çlü, P. Knaapen, H. J. Harms et al. “Myocardial efficiency is an important determinant of functional improvement after aortic valve replacement in aortic valve stenosis patients: a combined PET and CMR study.” Eur. Heart J. – Cardiovascular Imaging, vol16, pp. 882–889, 2015. [87] R. J. Hicks et al. “Assessment of myocardial oxidative metabolism in aortic valve disease using positron emission tomography with C-11 acetate.,” Am. Heart J., vol. 123, no. 3, pp. 653–64, 1992. [88] J. Schwitter et al. “Myocardial oxygen consumption in aortic valve disease with and without left ventricular dysfunction,” Br Hear. J, vol. 67, pp. 161–9, 1992. [89] H. M. Connolly et al. “Aortic valve replacement for aortic stenosis with severe left ventricular dysfunction. Prognostic indicators.,” Circulation, vol. 95, no. 10, pp. 2395–400, 1997. [90] H. L. Dauerman et al. “Early Recovery of Left Ventricular Systolic Function After CoreValve Transcatheter Aortic Valve Replacement.,” Circ. Cardiovasc. Interv., vol. 9, no. 6, 2016. [91] C. Tribouilloy et al., “Outcome After Aortic Valve Replacement for Low-Flow/Low-Gradient Aortic Stenosis Without Contractile Reserve on Dobutamine Stress Echocardiography,” J. Am. Coll. Cardiol., vol. 53, no. 20, pp. 1865–1873, 2009. [92] B. Vaquette et al., “Valve replacement in patients with critical aortic stenosis and depressed left ventricular function: Predictors of operative risk, left ventricular function recovery, and long term outcome,” Heart, vol. 91, no. 10, pp. 1324–1329, 2005. [93] D. Cramariuc et al. “Low-Flow Aortic Stenosis in Asymptomatic Patients. Valvular-Arterial Impedance and Systolic Function From the SEAS Substudy,” JACC Cardiovasc. Imaging, vol. 2, no. 4, pp. 390-399, 2009. [94] K. Kusunose et al. “Incremental prognostic value of left ventricular global longitudinal strain in patients with aortic stenosis and preserved ejection fraction,” Circ. Cardiovasc. Imaging, vol. 7, no. 6, pp. 938–945, 2014. [95] S. A. M. Nashef et al. “EuroSCORE II,” Eur. J. Cardio-Thoracic Surg., vol. 41, no. 4, pp. 734–745, 2012. [96] The Society of Thoracic Surgeons. “Risk Calculators | STS.” (Online). Available: https://www.sts.org/resources/risk-calculators. (Accessed: 21-Dec-2017). [97] S. C. Cannegieter, F. R. Rosendaal, and E. Briët. “Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses,” Circulation, vol. 89, no. 2, pp. 635–641, 1994. [98] D. R. Johnston et al. “Long-term durability of bioprosthetic aortic valves: Implications from 12,569 implants,” Ann. Thorac. Surg., vol. 99, no. 4, pp. 1239–1247, 2015. [99] N. Glaser, V. Jackson, M. J. Holzmann, A. Franco-Cereceda, and U. Sartipy, “Prosthetic Valve Endocarditis After Surgical Aortic Valve Replacement.,” Circulation, vol. 136, no. 3, pp. 329–331, 2017. [100] P. A. Pellikka, R. A. Nishimura, K. R. Bailey, and A. J. Tajik. “The natural history of adults with asymptomatic, hemodynamically significant aortic stenosis,” J. Am. Coll. Cardiol., vol. 15, no. 5, pp. 1012–1017, 1990. [101] S. C. Malaisrie et al. “Mortality while waiting for aortic valve replacement,” Ann. Thorac. Surg., vol. 98, no. 5, pp. 1564–1571, 2014. [102] R. Rosenhek, T. Binder, G. Porenta et al.“Predictors of outcome in severe, asymptomatic aortic stenosis,” N. Engl. J. Med., vol. 343, no. 9, pp. 611–617, 2000. [103] A. Flores-Marín et al. “Long-Term Predictors of Mortality and Functional Recovery After Aortic Valve Replacement for Severe Aortic Stenosis With Left Ventricular Dysfunction,” Rev. Española Cardiol. (English Ed.) vol. 63, no. 1, pp. 36–45, 2010. [104] J.-L. Monin, J. Quéré, M. Monchi et al. “Low-gradient aortic stenosis: operative risk stratification and predictors for long-term outcome: a multicenter study using dobutamine stress hemodynamics.,” Circulation, vol. 108, no. 3, pp. 319–24, 2003. [105] R. J. Everett, M. A. Clavel, P. Pibarot, and M. R. Dweck, “Timing of intervention in aortic stenosis: A review of current and future strategies,” Heart, vol. 104, no. 24, pp. 2067–2076, Dec. 2018. [106] D. J. Kumbhani. “Randomized Comparison of Early Surgery Versus Conventional Treatment in Very Severe Aortic Stenosis - American College of Cardiology.” (Online). Available: https://www.acc.org/latest-in-cardiology/clinical-trials/2019/11/15/17/34/recovery. (Accessed: 19-Feb-2020). [107] Z. Hachicha, J. G. Dumesnil and P. Pibarot, “Usefulness of the Valvuloarterial Impedance to Predict Adverse Outcome in Asymptomatic Aortic Stenosis,” J. Am. Coll. Cardiol., vol. 54, no. 11, pp. 1003–1011, 2009. [108] S. Sündermann, A. Dademasch, J. Praetorius et al. “Comprehensive assessment of frailty for elderly high-risk patients undergoing cardiac surgery,” Eur. J. Cardio-Thoracic Surg., vol. 39, no. 1, pp. 33–37, 2011. [109] J. Afilalo, M. J. Eisenberg, J. Morin et al. “Gait Speed as an Incremental Predictor of Mortality and Major Morbidity in Elderly Patients Undergoing Cardiac Surgery,” J. Am. Coll. Cardiol., vol. 56, No. 20. pp. 1668–1676, 2010. [110] A. Singh, J. P. Greenwood, C. Berry et al. “Comparison of exercise testing and CMR measured myocardial perfusion reserve for predicting outcome in asymptomatic aortic stenosis: the PRognostic Importance of MIcrovascular Dysfunction in Aortic Stenosis (PRIMID AS) Study,” Eur. Heart J., vol. 38, no. 16, pp. 1222–1229, 2017. [111] A. M. Rafique, S. Biner, I. Ray et al. “Meta-Analysis of Prognostic Value of Stress Testing in Patients With Asymptomatic Severe Aortic Stenosis,” Am. J. Cardiol., vol. 104, no. 7, pp. 972–977, 2009. [112] A. Vahanian, O. Alfieri, F. Andreotti et al. “Guidelines on the management of valvular heart disease (version 2012): The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS),” Eur. Heart J., vol. 33, no. 19, pp. 2451–2496, 2012. [113] C. M. Otto, I. G. Burwash, M. E. Legget et al. “Prospective study of asymptomatic valvular aortic stenosis. Clinical, echocardiographic, and exercise predictors of outcome.,” Circulation, vol. 95, no. 9, pp. 2262–70, 1997. [114] J. M. Paradis et al. “Aortic stenosis and coronary artery disease: What do we know? A comprehensive review of the literature with proposed treatment algorithms,” European Heart Journal, vol. 35, no. 31, 2014. [115] D. Brala, H. I. Michelena, M. E. Sarano et al. “Abstract 16957: Predictive Value of Cardiopulmonary Exercise Testing in Patients With Aortic Stenosis: Comparison With Traditional Echocardiographic Parameters,” Circulation, vol. 128, no. Suppl 22, 2013. [116] P. E. Sigvardsen, L. H. Larsen, H. G. Carstensen et al. “Six-minute walking test and long term prognosis in patients with asymptomatic aortic valve stenosis,” Int. J. Cardiol, vol. 249, pp. 334–339, 2017. [117] D. P. De Arenaza et al. “Preoperative 6-minute walk test adds prognostic information to Euroscore in patients undergoing aortic valve replacement,” Heart, vol. 96, no. 2, pp. 113–117, Jan. 2010. [118] O. Abdul-Jawad Altisent et al. “Predictors and Association With Clinical Outcomes of the Changes in Exercise Capacity After Transcatheter Aortic Valve Replacement,” Circulation, vol. 136, no. 7, pp. 632–643, 2017. [119] J. Petersen, E. Vettorazzi, L. Winter, et al. “Physical and mental recovery after conventional aortic valve surgery,” The Journal of Thoracic and Cardiovascular Surgery, Vol 152, No. 6 pp. 1549 1556.e2, 2016. [120] S. C. Mukhopadhyay, “Wearable Sensors for Human Activity Monitoring: A Review,” IEEE Sens. J., vol. 15, no. 3, pp. 1321–1330, 2015. [121] E. Chiauzzi, C. Rodarte, and P. DasMahapatra. “Patient-centered activity monitoring in the self-management of chronic health conditions.,” BMC Med., vol. 13, p. 77, 2015. [122] D. M. Sherrill, M. L. Moy, J. J. Reilly, and P. Bonato, “Using hierarchical clustering methods to classify motor activities of COPD patients from wearable sensor data.,” J. Neuroeng. Rehabil., vol. 2, no. 1, p. 16, 2005. [123] N. A. Fini, A. E. Holland, J. Keating et al. “How is physical activity monitored in people following stroke?,” Disabil. Rehabil., vol. 37, no. 19, pp. 1717–1731, 2015. [124] P. Castillejo, J.-F. Martinez, J. Rodriguez-Molina, and A. Cuerva, “Integration of wearable devices in a wireless sensor network for an E-health application,” IEEE Wirel. Commun., vol. 20, no. 4, pp. 38–49, 2013. [125] P. Green, A. E. Woglom, P. Genereux et al. “Gait Speed and Dependence in Activities of Daily Living in Older Adults With Severe Aortic Stenosis,” Clin. Cardiol., vol. 35, no. 5, pp. 307–314, 2012. [126] P. A. Toogood, M. P. Abdel, J. A. Spear et al. “The monitoring of activity at home after total hip arthroplasty,” Bone Joint J., vol. 98-B, no. 11, pp. 1450–1454, 2016. [127] A. J. Manson, P. Brown, J. D. O’Sullivan et al. “An ambulatory dyskinesia monitor.,” J. Neurol. Neurosurg. Psychiatry, vol. 68, no. 2, pp. 196–201, 2000. [128] G. Uswatte, W. L. Foo, H. Olmstead et al. “Ambulatory monitoring of arm movement using accelerometry: an objective measure of upper-extremity rehabilitation in persons with chronic stroke.,” Arch. Phys. Med. Rehabil., vol. 86, no. 7, pp. 1498–501, 2005. [129] M. W. A. van Geldorp, H. J. Heuvelman, A. P. Kappetein et al., “Quality of life among patients with severe aortic stenosis,” Netherlands Hear. J., vol. 21, no. 1, pp. 21–27, 2013. [130] National Institute of Biomedical Imaging and Bioengineering. \"Basics of modelling what it is -Computational Modeling” (Online). Available: https://www.nibib.nih.gov/science-education/science-topics/computational-modeling. (Accessed: 23-Nov-2017). [131] A. Garny, D. Noble, and P. Kohl, “Dimensionality in cardiac modelling,” Prog. Biophys. Mol. Biol. vol. 87, no. 1, pp. 47–66, 2005. [132] Y. Shi, P. Lawford, and R. Hose, “Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System,” Biomed. Eng. Online, vol. 10, no. 1, p. 33, 2011. [133] H. Mohammadi and K. Mequanint, “Prosthetic aortic heart valves: Modeling and design,” Med. Eng. Phys., vol. 33, no. 2, pp. 131–147, 2011. [134] S. Tu, E. Barbato, Z. Köszegi et al. “Fractional Flow Reserve Calculation From 3-Dimensional Quantitative Coronary Angiography and TIMI Frame Count,” JACC Cardiovasc. Interv., vol. 7, no. 7, pp. 768–777, 2014. [135] B. T. Tang, S. S. Pickard, F. P. Chan, et al. “Wall Shear Stress is Decreased in the Pulmonary Arteries of Patients with Pulmonary Arterial Hypertension: An Image-Based, Computational Fluid Dynamics Study,” Pulm. Circ., vol. 2, no. 4, pp. 470–476, 2012. [136] P. D. Morris, A. Narracott, H. von Tengg-Kobligk et al. “Computational fluid dynamics modelling in cardiovascular medicine,” Heart, vol. 102, no. 1, pp. 18–28, 2016. [137] NICE. “HeartFlow FFRCT for estimating fractional flow reserve from coronary CT angiography\" (Online) Medical technologies guidance [MTG32]. 2017. Available: https://www.nice.org.uk/guidance/mtg32 (Accessed: 04-06-2019). [138] P. A. L. Tonino, B. De Bruyne, N. H. J. Pijls et al. “Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention,” N. Engl. J. Med., vol. 360, no. 3, pp. 213–224, 2009. [139] D. Noble, A. Garny, and P. J. Noble. “How the Hodgkin-Huxley equations inspired the Cardiac Physiome Project,” J. Physiol., vol. 590, no. 11, pp. 2613–2628, 2012. [140] N. A. Trayanova. “Whole-Heart Modeling Applications to Cardiac Electrophysiology and Electromechanics,” Circ Res.Circ Res.Circ Res, vol. 108, pp. 70–8485, 2011. [141] G. Biglino, C. Capelli, J. Bruse et al. “Computational modelling for congenital heart disease: how far are we from clinical translation?” Heart, vol. 103, pp. 98-103, 2017. [142] L. Itu, P. Sharma, K. F. Ralovich et al. “Non-Invasive Hemodynamic Assessment of Aortic Coarctation: Validation with In Vivo Measurements,” Annals of Biomedical Engineering, vol. 41, no. 4, April pp. 669–681, 2013. [143] M. A. Quail and A. M. Taylor. “Computer Modeling to Tailor Therapy for Congenital Heart Disease.” Curr Cardiol Rep, 15, pp. 395, 2013. [144] B. Su, L. Zhong, X. Wang et al. “Numerical simulation of patient-specific left ventricular model with both mitral and aortic valves by FSI approach,” Comput. Methods Programs Biomed., vol. 113, no. 2, pp. 474–482, 2014. [145] R. Gorlin and S. G. Gorlin. “Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I,” Am. Heart J., vol. 41, no. 1, pp. 1–29, 1951. [146] K. Sagawa, R. K. Lie, and J. Schaefer. “Translation of Otto Frank’s paper, Zeitschrift für Biologie\" 37: 483-526 (1899),” J. Mol. Cell. Cardiol., vol. 22, no. 3, pp. 253–4, 1990. [147] C. M. Lloyd, J. R. Lawson, P. J. Hunter, and P. F. Nielsen. “The CellML Model Repository,” Bioinformatics, vol. 24, no. 18, pp. 2122–2123, 2008. [148] N. Westerhof, G. Elzinga, and P. Sipkema. “An artificial arterial system for pumping hearts,” J. Appl. Physiol., vol. 31, no. 5, pp. 776–81, 1971. [149] H. M. Spotnitz. “Macro design, structure, and mechanics of the left ventricle,” J. Thorac. Cardiovasc. Surg., vol. 119, no. 5, pp. 1053–1077, 2000. [150] T. O’Hara, L. Virág, A. Varró, and Y. Rudy. “Simulation of the Undiseased Human Cardiac Ventricular Action Potential: Model Formulation and Experimental Validation,” PLoS Comput. Biol., vol. 7, no. 5, p. e1002061, 2011. [151] C. A. Taylor and C. A. Figueroa. “Patient-Specific Modeling of Cardiovascular Mechanics,” Annu. Rev. Biomed. Eng. 11, pp. 109–34. 2009. [152] M. S. Vieira, T. Hussain, and C. A. Figueroa. “Patient-Specific Image-Based Computational Modeling in Congenital Heart Disease: A Clinician Perspective,” J. Cardiol. Ther., vol. 2, no. 6, pp. 436–448, 2015. [153] S. F. C. Stewart, P. Hariharan, E. G. Paterson et al. “Results of FDA’s First Interlaboratory Computational Study of a Nozzle with a Sudden Contraction and Conical Diffuser,” Cardiovasc. Eng. Technol., vol. 4, no. 4, pp. 374–391, 2013. [154] J. R. Cebral, M. A. Castro, S. Appanaboyina et al. “Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity.,” IEEE Trans. Med. Imaging, vol. 24, no. 4, pp. 457–67, 2005. [155] C.A. Taylor. “Method and system for image processing to determine patient-specific blood flow characteristics,” HeartFlow Inc. US Patent US20160113528A1. 2015. [156] C. E. Hann, J. G. Chase, T. Desaive et al. “Unique parameter identification for cardiac diagnosis in critical care using minimal data sets,” Comput. Methods Programs Biomed., vol. 99, pp. 75–87. 2010. [157] S. Walton, O. Hassan, and K. Morgan. “Reduced order modelling for unsteady fluid flow using proper orthogonal decomposition and radial basis functions,” Appl. Math. Model., vol. 37, no. 20–21, pp. 8930–8945, 2013. [158] C. E. Hann, J. Revie, D. Stevenson et al. “Patient Specific Identification of the Cardiac Driver Function in a Cardiovascular System Model.” Computer Methods and Programs in Biomedicine, Vol. 101. No. 2. pp. 201-207, 2011. [159] K. B. Chandran and H. Kim. “Computational Mitral Valve Evaluation and Potential Clinical Applications,” Ann. Biomed. Eng., vol. 43, no. 6, pp. 1348–1362, 2015. [160] A. G. Brown, Y. Shi, A. Arndt, et al. “Importance of realistic LVAD profiles for assisted aortic simulations: evaluation of optimal outflow anastomosis locations,” Comput. Methods Biomech. Biomed. Engin., vol. 15, no. 6, pp. 669–680, 2012. [161] K. Sughimoto, F. Liang, Y. Takahara et al. “Assessment of cardiovascular function by combining clinical data with a computational model of the cardiovascular system,” J. Thorac. Cardiovasc. Surg., vol. 145, pp. 1367–1372, 2013. [162] T. A. Quinn and P. Kohl. “Combining wet and dry research: experience with model development for cardiac mechano-electric structure-function studies,” Cardiovasc. Res., vol. 97, no. 4, pp. 601–611, 2013. [163] S. A. Niederer and N. P. Smith, “At the heart of computational modelling.,” J. Physiol., vol. 590, no. 6, pp. 1331–8, 2012. [164] D. Houle, D. R. Govindaraju, and S. Omholt. “Phenomics: the next challenge,” Nat. Rev. Genet., vol. 11, no. 12, pp. 855–866, 2010. [165] P. Segers, E. R. Rietzschel, M. L. De Buyzere et al., “Three- and four-element Windkessel models: Assessment of their fitting performance in a large cohort of healthy middle-aged individuals,” Proc. Inst. Mech. Eng. Part H J. Eng. Med., vol. 222, no. 4, pp. 417–428, 2008. [166] J. K. Li, J. Y. Zhu, and M. Nanna. “Computer modeling of the effects of aortic valve stenosis and arterial system afterload on left ventricular hypertrophy.,” Comput. Biol. Med., vol. 27, no. 6, pp. 477–85, 1997. [167] B. W. Smith, J. G. Chase, R. I. Nokes, et al. “Minimal haemodynamic system model including ventricular interaction and valve dynamics,” Med. Eng. Phys., vol. 26, no. 2, pp. 131–139, 2004. [168] D. Garcia, P. J. C. Barenbrug, P. Pibarot et al. “A ventricular-vascular coupling model in presence of aortic stenosis,” Am. J. Physiol. Heart Circ. Physiol., vol. 288, no. 4, pp. H1874-84, 2005. [169] K. Sagawa, H. Suga, A. A. Shoukas, and K. M. Bakalar. “End-systolic pressure/volume ratio: A new index of ventricular contractility,” Am. J. Cardiol., vol. 40, no. 5, pp. 748–753, 1977. [170] K. Sagawa. “The end-systolic pressure-volume relation of the ventricle: Definition, modifications and clinical use,” Circulation, vol. 63, no. 6 I. pp. 1223–1227, 1981. [171] D. Burkhoff. “Pressure-volume loops in clinical research,” Journal of the American College of Cardiology, vol. 62, no. 13. Elsevier USA, pp. 1173–1176, 2013. [172] B. Ky, B. French, A. May Khan et al. “Ventricular-arterial coupling, remodeling, and prognosis in chronic heart failure,” J. Am. Coll. Cardiol., vol. 62, no. 13, pp. 1165–1172, 2013. [173] F. Seemann, P. Arvidsson, D. Nordlund, et al. “Noninvasive Quantification of Pressure-Volume Loops From Brachial Pressure and Cardiovascular Magnetic Resonance,” Circ. Cardiovasc. Imaging, vol. 12, no. 1, p. e008493, 2019. [174] P. Steendijk. “Pressure-volume measurements by conductance catheter during cardiac resynchronization therapy,” Eur. Hear. J. Suppl., vol. 6, pp. D35–D42, 2004. [175] J. Baan, T. Van Der Velde, H. G. De Bruin et al. “Continuous measurement of left ventricular volume in animals and humans by conductance catheter.” Circulation vol. 70, no. 5, pp. 812-823, 1984. [176] D. Georgakopoulos, W. A. Mitzner, C. Chen-Huan et al., “In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry,” Am. J. Physiol., vol. 274, no. 4 PART2, 1998. [177] American Heart Association. “Heart Valve Surgery Recovery and Follow Up,” 2016. (Online). Available: http://www.heart.org/HEARTORG/Conditions/More/HeartValveProblemsandDisease/Heart-Valve-Surgery-Recovery-and-Follow-Up_UCM_450700_Article.jsp#.Wvg2tmgvyUk. (Accessed: 13-May-2018). [178] European Commission Directorate General for Communications Networks, \"EurValve Deliverable 4.1: Digital Patient Definition.” Horizon 2020, PHC-30-2015, 689617,Research and Innovation Action, 2016. (Online). Available: https://cordis.europa.eu/project/id/689617/results. (Accessed: 04-06-2019). [179] New York Heart Association. “The Criteria Committee for the New York Heart Association. Nomenclature and Criteria for Diagnosis of Diseases of the Heart and Great Vessels.,” Little, Brown Co., Boston, MA, USA, no. 9th ed., pp. 253–255, 1994. [180] J. Eldridge and D. Richley. “Clinical Guidelines by Consensus Recording a standard 12-lead electrocardiogram,” Society for Cardiological Science & Technology (SCST). v2, pp1-26, 2014. [181] R. Wheeler, R. Steeds, B. Rana et al. “A minimum dataset for a standard transoesophageal echocardiogram: A guideline protocol from the British Society of Echocardiography,” Echo Research and Practice, vol. 2, no. 4, pp. G29–G45, 015. [182] T. H. Solutions, “TrialConnect.” [Online]. 2019. Available: https://dhzb.trialconnect.de/home. [Accessed: 19-Dec-2019]. [183] D. Pennell, U. P. Sechtem, C. B. Higgins et al. “Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?,” Eur. Heart J., vol. 25, no. 21, pp. 1940–1965, 2004. [184] R. Lorenz, J. Bock, J. Snyder et al. “Influence of eddy current, Maxwell and gradient field corrections on 3D flow visualization of 3D CINE PC-MRI data,” Magnetic Resonance in Medicine, vol. 72, no. 1., pp. 33–40, 2014. [185] M. E. MacDonald, N. D. Forkert, G. B. Pike, and R. Frayne. “Phase error correction in time-averaged 3D phase contrast magnetic resonance imaging of the cerebral vasculature,” PLoS One, vol. 11, no. 2, 2016. [186] D. C. Ghiglia and M. D. Pritt, Two-dimensional phase unwrapping : theory, algorithms, and software. Wiley, New Jersey, USA. 1998. [187] K. S. Nayak, J. F. Nielsen, M. A. Bernstein et al. “Cardiovascular magnetic resonance phase contrast imaging,” Journal of Cardiovascular Magnetic Resonance, vol. 17, no. 1, 2015. [188] N. Stergiopulos, J.-J. Meister, and N. Westerhof. “Determinants of stroke volume and systolic and diastolic aortic pressure,” Am. J. Physio, vol 270, no. 39, pp. H2050-H2059, 1996. [189] J. P. Mynard, M. R. Davidson, D. J. Penny, and J. J. Smolich, “A simple, versatile valve model for use in lumped parameter and one-dimensional cardiovascular models,” Int. j. numer. method. biomed. eng., vol. 28, no. 6–7, pp. 626–641, 2012. [190] P. D. Chantler, E. G. Lakatta, and S. S. Najjar, “Arterial-ventricular coupling: Mechanistic insights into cardiovascular performance at rest and during exercise,” Journal of Applied Physiology, vol. 105, no. 4. American Physiological Society, pp. 1342–1351, 2008. [191] T. Bombardini, L. A. Mulieri, S. Salvadori et al., “Pressure-volume Relationship in the Stress-echocardiography Laboratory: Does (Left Ventricular End-diastolic) Size Matter?,” Rev Esp Cardiol, vol. 70, no. 2, pp. 96–104, 2017. [192] M. Hoeijmakers, M. Rochette, M. Kasztelnik. et al “Real-Time Patient-Specific Transaortic Pressure Gradient Computation from Parameterized Aortic Valve Geometries .” 8th World Congress of Biomechanics, Dublin, 2018. [193] S. F. Nagueh, K. J. Middleton, H. A. Kopelen, et al. “Doppler tissue imaging: a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures,” J. Am. Coll. Cardiol., vol. 30, no. 6, pp. 1527–33, 1997. [194] G. Wharton, R. Steeds, J. Allen et al. “A minimum dataset for a standard adult transthoracic echocardiogram: A guideline protocol from the British Society of echocardiography,” Echo Research and Practice, vol. 2, no. 1. BioScientifica Ltd., pp. G9–G24, 2015. [195] P. M. Heerdt, S. Korfhagen, H. Ezz, and C. Oromendia. “Accuracy of a Simulation Algorithm for Modelling LV Contractility, Diastolic Capacitance, and Energetics Using Data Available From Common Hemodynamic Monitors and Echocardiography,” J. Cardiothorac. Vasc. Anesth., vol. 32, no. 1, pp. 381–388, 2018. [196] H. Asanoi, S. Sasayama, and T. Kameyama, “Ventriculoarterial coupling in normal and failing heart in humans,” Circ. Res., vol. 65, no. 2, pp. 483–493, 1989. [197] J. Pope, R. McConville, M. Kozlowski et al., “SPHERE in a Box: Practical and Scalable EurValve Activity Monitoring Smart Home Kit,” 2017 IEEE 42nd Conference on Local Computer Networks Workshops, LCN Workshops, pp. 128–135, 2017. [198] J. Hendrikx, L. S. Ruijs, L. G. Cox, P. M. Lemmens et al. “Clinical Evaluation of the Measurement Performance of the Philips Health Watch: A Within-Person Comparative Study.,” JMIR mHealth uHealth, vol. 5, no. 2, p. e10, 2017. [199] P. Chodór, K. Wilczek, T. Zielińska et al., “Assessment of cardiovascular function following transcatheter aortic valve implantation based on six-minute walk test,” Cardiol. J., vol. 24, no. 2, pp. 167–175, 2017. [200] B. Iung. “Quality of life after transcatheter aortic valve implantation: the need for more a complete appraisal,” Eur. Hear. J. - Qual. Care Clin. Outcomes, vol. 2, no. 3, pp. 147–148, 2016. [201] R. O. Crapo, R. Casaburi, A. L. Coates et al. “ATS statement: Guidelines for the six-minute walk test,” American Journal of Respiratory and Critical Care Medicine, vol. 166, no. 1. American Lung Association, pp. 111–117, 2002. [202] Thamhain Hans. “Accelerating product developments via phase-gate processes,”, Project Management Institute Annual Seminars & Symposium, Houston, Texas 2000. [203] D. Riebe, J. K. Ehrman, G. Liguori, and M. Magal , ACSM’s guidelines for exercise testing and prescription, Tenth Edition. American College of Sports Medicine. Wolters Kluwer, Baltimore, Maryland, 2017. [204] P. L. Enright and D. L. Sherrill. “Reference equations for the six-minute walk in healthy adults,” Am. J. Respir. Crit. Care Med., vol. 158, no. 5 PART I, pp. 1384–1387, 1998. [205] P. L. Enright, M. A. McBurnie, V. Bittner et al. “The 6-min walk test: A quick measure of functional status in elderly adults,” Chest, vol. 123, no. 2, pp. 387–3982003. [206] P. L. Enright. “The six-minute walk test,” Respiratory Care, vol. 48, no. 8, pp. 783–785, 2003. [207] C. Holmes and N. Briffa. “Patient-Reported Outcome Measures (PROMS) in patients undergoing heart valve surgery: why should we measure them and which instruments should we use?,” Open Hear., vol. 3, no. 1, p. e000315, 2016. [208] L. Shan, A. Saxena, R. Mcmahon, el al. “A systematic review on the quality of life benefits after aortic valve replacement in the elderly,” J. Thorac. Cardiovasc. Surg., vol. 145, pp. 1173–1189, 2013. [209] A. Bilbao, A. Escobar, L. García-Perez et al. “The Minnesota living with heart failure questionnaire: comparison of different factor structures.,” Health Qual. Life Outcomes, vol. 14, p. 23, 2016. [210] World Health Organization. \"WHOQOL-BREF, Field Trial Version\", WHO Programme On Mental Health, Geneva, pp 17-18 1996. [211] A. Kaladji, A. Lucas, G. Kervio, et al. “Sizing for Endovascular Aneurysm Repair: Clinical Evaluation of a New Automated Three-Dimensional Software,” Ann. Vasc. Surg., vol. 24, no. 7, pp. 912–920, 2010. [212] H. Feuillâtre, V. Auffret, M. Castro, et al. “Study of similarity measures for case-based reasoning in transcatheter aortic valve implantation,” Computing in Cardiology, vol. 44, pp. 1–4, 2017. [213] J. M. LeBreton and J. L. Senter. “Answers to 20 Questions About Interrater Reliability and Interrater Agreement,” Organ. Res. Methods, vol. 11, no. 4, pp. 815–852, 2008. [214] M. Handke, G. Heinrichs, F. Beyersdorf, et al.“In vivo analysis of aortic valve dynamics by transesophageal 3-dimensional echocardiography with high temporal resolution,” J. Thorac. Cardiovasc. Surg., vol. 125, no. 6, pp. 1412–1419, 2003. [215] G. Borg. Physical performance and perceived exertion. Lund, Copenhagen: Berlingska boktryckeriet, C. W. K. Gleerup. 1962. [216] European Commission Directorate General for Communications Networks, \" EurValve Deliverable 4.6: Activity Monitoring.” Horizon 2020, PHC-30-2015, 689617,Research and Innovation Action, 2018. (Online). Available: https://cordis.europa.eu/project/id/689617/results. (Accessed: 04-06-2019). [217] J. S. Dahl, A. Brandes, M. K. Poulsen, et al. “Atrial fibrillation in severe aortic valve stenosis - Association with left ventricular left atrial remodeling,” IJC Hear. Vessel., vol. 4, no. 1, pp. 102–107, 2014. [218] M. Rigolli, S. Anandabaskaran, J. P. Christiansen, and G. A. Whalley. “Bias associated with left ventricular quantification by multimodality imaging: a systematic review and meta-analysis,” Open Hear., vol. 3, no. 1, p. e000388, 2016. [219] A. D’Andrea, F. Ferrara, R. Cocchia et al. “Reference ranges and physiologic variations of left E/e’ ratio in healthy adults: Clinical and echocardiographic correlates,” J. Cardiovasc. Echogr., vol. 28, no. 2, pp. 101–108, 2018. [220] B. Villari, G. Vassaili, E. S. Monrad et al. “Normalization of diastolic dysfunction in aortic stenosis late after valve replacement,” Circulation, vol. 91, no. 9, pp. 2353–2358, 1995. [221] P. Gjertsson, K. Caidahl, and O. Bech-Hanssen. “Left ventricular diastolic dysfunction late after aortic valve replacement in patients with aortic stenosis,” Am. J. Cardiol., vol. 96, no. 5, pp. 722–727, 2005. [222] W. Ma, W. Zhang, W. Shi, Y. Kong, and X. Ma. “Left Ventricular Diastolic Function After Aortic Valve Replacement for Chronic Aortic Regurgitation,” Ann. Thorac. Surg., vol. 106, pp24–9, 2018. [223] M. Dalsgaard, J. Kjaergaard, R. Pecini et al. “Left Ventricular Filling Pressure Estimation at Rest and During Exercise in Patients With Severe Aortic Valve Stenosis: Comparison of Echocardiographic and Invasive Measurements,” J. Am. Soc. Echocardiogr., vol. 22, no. 4, pp. 343–349, 2009. [224] J. Greupner, E. Zimmermann, A. Grohmann et al., “Head-to-Head Comparison of Left Ventricular Function Assessment with 64-Row Computed Tomography, Biplane Left Cineventriculography, and Both 2- and 3-Dimensional Transthoracic Echocardiography: Comparison With Magnetic Resonance Imaging as the Reference Standard,” J. Am. Coll. Cardiol., vol. 59, no. 21, pp. 1897–1907, 2012. [225] E. Villa et al. “Factors affecting left ventricular remodeling after valve replacement for aortic stenosis. An overview,” Cardiovascular Ultrasound, vol. 4. BioMed Central, p. 25, 2006. [226] A. Ali, A. Patel, Z. Ali, et al. “Enhanced left ventricular mass regression after aortic valve replacement in patients with aortic stenosis is associated with improved long-term survival,” J. Thorac. Cardiovasc. Surg., vol. 142, no. 2, pp. 285–291, 2011. [227] M. Natsuaki, T. Itoh, S. Tomita, and K. Naito, “Reversibility of cardiac dysfunction after valve replacement in elderly patients with severe aortic stenosis.,” Ann. Thorac. Surg., vol. 65, no. 6, pp. 1634–8, 1998. [228] H. P. Beyerbacht, H.J Lamb, A. Van Der Laarse, et al. “Aortic valve replacement in patients with aortic valve stenosis improves myocardial metabolism and diastolic function,” Radiology, vol. 219, no. 3, pp. 637–643, 2001. [229] M. Gaudino, F. Alessandrini, F. Glieca, et al, “Survival after aortic valve replacement for aortic stenosis: does left ventricular mass regression have a clinical correlate?,” Eur. Heart J., vol. 26, no. 1, pp. 51–7, 2005. [230] R. S. Szwarc, D. Laurent, P. R. Allegrini, and H. A. Ball. “Conductance catheter measurement of left ventricular volume: Evidence for nonlinearity within cardiac cycle,” Am. J. Physiol. - Hear. Circ. Physiol., vol. 268, no. 4 37-4, 1995. [231] C. S. Hayward, W. V. Kalnins, and R. P. Kelly. “Gender-related differences in left ventricular chamber function,” Cardiovasc. Res., vol. 49, no. 2, pp. 340–350, 2001. [232] G. S. Ribeiro, R. D. Melo, L. F. Deresz, et al. “European Society of Cardiology: Cardiac rehabilitation programme after transcatheter aortic valve implantation versus surgical aortic valve replacement: Systematic review and meta-analysis.” European Journal of Preventive Cardiology, vol. 24, no. 7, pp. 688–697, 2017. [233] N. Straiton, K. Jin, R. Bhindi, and R. Gallagher, “Functional capacity and health-related quality of life outcomes post transcatheter aortic valve replacement: a systematic review and meta-analysis.,” Age Ageing, vol. 47, no. 3, pp. 478–482, 2018. [234] P. Green, A. Kirtane, P. Genereux et al., “The Impact Of Six–Minute Walk Test Performance On Outcomes After Transcatheter Aortic Valve Replacement: Insights From The Partner Trial,” J. Am. Coll. Cardiol., vol. 61, no. 10, pp. E1971, 2013. [235] O. Abdul-Jawad Altisent et al. “Predictors and Association With Clinical Outcomes of the Changes in Exercise Capacity After Transcatheter Aortic Valve Replacement.,” Circulation, vol. 136, no. 7, pp. 632–643, 2017. [236] C. A. Kim, S. P. Rasania, J. Afilalo, et al. “Functional Status and Quality of Life After Transcatheter Aortic Valve Replacement,” Ann. Intern. Med., vol. 160, no. 4, p. 243, 2014. [237] H. Baumgartner, J. Hung, J. Bermejo et al. “Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European Association of Cardiovascular Imaging and the American Society of Echocardiography,” Eur. Hear. J. - Cardiovasc. Imaging, vol. 18, no. 3, pp. 254–275, 2017. [238] H. Baumgartner, T. Stefenelli, J. Niederberger, et al. “‘Overestimation’ of catheter gradients by Doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery.,” J. Am. Coll. Cardiol., vol. 33, no. 6, pp. 1655–61, 1999. [239] A. E. Abbas and P. Pibarot. “Hemodynamic characterization of aortic stenosis states,” Catheter. Cardiovasc. Interv., vol. 93, no. 5, pp. 1002–1023, 2019. [240] E. Y. L. Lui, A. H. Steinman, R. S. C. Cobbold, and K. W. Johnston. “Human factors as a source of error in peak Doppler velocity measurement,” J. Vasc. Surg., vol. 42, no. 5, pp. 972.e1-972.e10, 2005. [241] M. Kanski et al. “Whole-heart four-dimensional flow can be acquired with preserved quality without respiratory gating, facilitating clinical use: a head-to-head comparison,” BMC Med. Imaging, vol. 15, no. 1, p. 20, 2015. [242] P. Garg, S. Crandon, P. P. Swoboda et al. “Left ventricular blood flow kinetic energy after myocardial infarction - Insights from 4D flow cardiovascular magnetic resonance,” J. Cardiovasc. Magn. Reson., vol. 20, no. 1, p. 61, Aug. 2018. [243] P. Garg, R. J. van der Geest, P. P. Swoboda et al., “Left ventricular thrombus formation in myocardial infarction is associated with altered left ventricular blood flow energetics.,” Eur. Heart J. Cardiovasc. Imaging, vol. 20, no. 1, pp. 108–117, 2019. [244] S. Crandon, J. J. M. Westenberg, P. P. Swoboda et al. “Impact of Age and Diastolic Function on Novel, 4D flow CMR Biomarkers of Left Ventricular Blood Flow Kinetic Energy,” Sci. Rep., vol. 8, no. 1, p. 14436, 2018. [245] M. Briand et al. “Reduced systemic arterial compliance impacts significantly on left ventricular afterload and function in aortic stenosis: Implications for diagnosis and treatment,” J. Am. Coll. Cardiol., vol. 46, no. 2, pp. 291–298, 2005. [246] F. Antonini-Canterin, G. Huang, E. Cervesato et al. “Symptomatic aortic stenosis: Does systemic hypertension play an additional role?,” Hypertension, vol. 41, no. 6, pp. 1268–1272, 2003. [247] G. E. Pate, “Association between aortic stenosis and hypertension.” J. Heart Valve Dis., vol. 11, no. 5, pp. 612–4, 2002. [248] S. Bozkurtid. “Mathematical modeling of cardiac function to evaluate clinical cases in adults and children,” 2019. [249] D. A. Kass, R. Beyar, E. Lankford, et al. “Influence of contractile state on curvilinearity of in situ end-systolic pressure-volume relations.,” Circulation, vol. 79, no. 1, pp. 167–78, 1989. [250] D. Burkhoff, S. Sugiura, D. T. Yue, and K. Sagawa, “Contractility-dependent curvilinearity of end-systolic pressure-volume relations.,” Am. J. Physiol., vol. 252, no. 6 Pt 2, pp. H1218-27, 1987. [251] T. Noda, C. P. Cheng, P. P. De Tombe, and W. C. Little, “Curvilinearity of LV end-systolic pressure-volume and dP/dtmax-end-diastolic volume relations.,” Am. J. Physiol., vol. 265, no. 3 Pt 2, pp. H910-7, 1993. [252] E. A. Ten Brinke, R. J. Klautz, H. F. Verwey, et al. “Single-beat estimation of the left ventricular end-systolic pressure-volume relationship in patients with heart failure,” Acta Physiol., vol. 198, no. 1, pp. 37–46, 2010. [253] T. Kind, N. Westerhof, T. J. C. Faes, et al.“Cardiac phase-dependent time normalization reduces load dependence of time-varying elastance,” Am. J. Physiol. - Hear. Circ. Physiol., vol. 296, no. 2, pp. H342-9, 2009. [254] Z. M. Malik and M. Zammert. “Anesthetic goals in patients with valvular heart disease,” in Essential Clinical Anesthesia Review, L. S. Aglio, R. W. Lekowski, and R. D. Urman, Eds. Cambridge: Cambridge University Press, pp. 18–21, 2015 [255] J. S. Dahl, S. Barros-Gomes, L. Videbaek et al. “Early Diastolic Strain Rate in Relation to Systolic and Diastolic Function and Prognosis in Aortic Stenosis,” JACC Cardiovasc. Imaging, vol. 9, pp. 519–528, 2016. [256] E. M. Vollema, T. Sugimoto, M. Shen et al. “Association of left ventricular global longitudinal strain with asymptomatic severe aortic stenosis natural course and prognostic value,” JAMA Cardiol., vol. 3, no. 9, pp. 839–847, 2018. [257] R. Bing, R. J. C. Everett, C. Tuck, et al. “Rationale and design of the randomized, controlled Early Valve Replacement Guided by Biomarkers of Left Ventricular Decompensation in Asymptomatic Patients with Severe Aortic Stenosis (EVOLVED) trial,” Am. Heart J., vol. 212, pp. 91–100, 2019. [258] P. Green, S. Kodali, M. B. Leon, and M. S. Maure. “Echocardiographic assessment of pressure volume relations in heart failure and valvular heart disease: Using imaging to understand physiology,” Minerva Cardioangiologica, vol. 59, no. 4. pp. 375–389, 2011. [259] R. J. Baciie, Y. Wang, and C. R. Jorgensen, “Hemodynamic Effects of Exercise in Isolated Valvular Aortic Stenosis.” Circulation; Volume XLIV, pp. 1003-1013, 1971. [260] R. Bilkhu, M. Jahangiri, and C. M. Otto, “Patient-prosthesis mismatch following aortic valve replacement,” Heart, vol. 105, no. Suppl 2, pp. S28–S33, 2019. [261] S. Ito, W. Miranda, J. Thaden et al. “Impact of Left Ventricular Ejection Fraction Between 50 And 60% Versus ≥60% on Mortality After Aortic Valve Replacement for Severe Aortic Stenosis,” J. Am. Coll. Cardiol., vol. 71, no. 11, p. A1968, 2018. [262] A. Furer, S.Chen, B.Redfors et al. “Effect of Baseline Left Ventricular Ejection Fraction on 2-Year Outcomes After Transcatheter Aortic Valve Replacement: Analysis of the PARTNER 2 Trials.,” Circ. Heart Fail., vol. 12, no. 8, p. e005809, 2019. [263] C. Raphael, C. Briscoe, J. Davies et al. “Limitations of the New York Heart Association functional classification system and self-reported walking distances in chronic heart failure,” Heart, vol. 93, no. 4, pp. 476–482, 2007. [264] E. Spitzer, R. T. Hahn, P. Pibarot et al. “Aortic Stenosis and Heart Failure: Disease Ascertainment and Statistical Considerations for Clinical Trials,” Card. Fail. Rev., vol. 5, no. 2, pp. 99–105, 2019. [265] C. Castaneda, K. Nalley, C. Mannion et al. “Clinical decision support systems for improving diagnostic accuracy and achieving precision medicine,” J. Clin. Bioinforma., vol. 5, no. 1, 2015. [266] R. Kaushal, K. G. Shojania, and D. W. Bates, “Effects of computerized physician order entry and clinical decision support systems on medication safety: A systematic review,” Archives of Internal Medicine, vol. 163, no. 12. pp. 1409–1416, 2003. [267] D. W. Bates, J. M. Teich, J. Lee et al. “The impact of computerized physician order entry on medication error prevention,” J. Am. Med. Informatics Assoc., vol. 6, no. 4, pp. 313–321, 1999. [268] O. Eminaga, M. Abbas, R. Hinkelammert et al. “CMDX©-based single source information system for simplified quality management and clinical research in prostate cancer,” BMC Med. Inform. Decis. Mak., vol. 12, no. 1, p. 141, 2012. [269] D. A. Berry, E. S. Iversen, D. F. Gudbjartsson et al., “BRCAPRO validation, sensitivity of genetic testing of BRCA1/BRCA2, and prevalence of other breast cancer susceptibility genes,” J. Clin. Oncol., vol. 20, no. 11, pp. 2701–2712, 2002. [270] M. W. M. Jaspers, M. Smeulers, H. Vermeulen, and L. W. Peute, “Effects of clinical decision-support systems on practitioner performance and patient outcomes: A synthesis of high-quality systematic review findings,” J. Am. Med. Informatics Assoc., vol. 18, no. 3, pp. 327–334, 2011. [271] T. J. Bright, A. Wong, R. Dhurjati et al., “Effect of clinical decision-support systems: A systematic review,” Annals of Internal Medicine, vol. 157, no. 1. American College of Physicians, pp. 29–43, 2012. [272] J. Petersen, E. Vettorazzi, L. Winter et al. “Physical and mental recovery after conventional aortic valve surgery,” J. Thorac. Cardiovasc. Surg., vol. 152, no. 6, pp. 1549-1556.e2, 2016. [273] GE Healthcare “CARESCAPE V100 Vital Signs Monitor .” (Online) CARESCAPE V100 SpecificationDOC0385787 rev7 4/2020. Available: https://www.vingmed.dk/wp-content/uploads/sites/3/2020/06/CARESCAPE-V100-Spec-Sheet_DOC0385787-rev7.pdf (Accessed: 05-05-20). [274] W. G. O’Dell. “Accuracy of Left Ventricular Cavity Volume and Ejection Fraction for Conventional Estimation Methods and 3D Surface Fitting.,” J. Am. Heart Assoc., vol. 8, no. 6, p. e009124, 2019. [275] W. Kroon, M. Bosboom, W. Huberts et al. “Computational model for estimating the short- and long-term cardiac response to arteriovenous fistula creation for hemodialysis,” Med. Biol. Eng. Comput., vol. 50, no. 12, pp. 1289–1298, 2012. [276] R. McConville, G. Archer, I. Craddock et al., “Online Heart Rate Prediction using Acceleration from a Wrist Worn Wearable.” KDD Workshop on Machine Learning for Medicine and Healthcare. London, UK. 2018. [277] Z. Keshavarz-Motamed, J. Garcia, E. Gaillard et al. “Non-Invasive Determination of Left Ventricular Workload in Patients with Aortic Stenosis Using Magnetic Resonance Imaging and Doppler Echocardiography,” PLoS One, vol. 9, no. 1, p. e86793, 2014. [278] P. Youssefi, A. Gomez, T. He et al., “Patient-specific computational fluid dynamics—assessment of aortic hemodynamics in a spectrum of aortic valve pathologies,” J. Thorac. Cardiovasc. Surg., vol. 153, no. 1, pp. 8-20.e3, 2017. [279] H. Suga, R. Hisano, Y. Goto, and O. Yamada, “Normalization of end systolic pressure volume relation and emax of different sized hearts,” Jpn. Circ. J., vol. 48, no. 2, pp. 136–143, 1984. [280] D. Burkhoff, I. Mirsky, H. Suga, and D. Burkhoff, “Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers,” Am J Physiol Hear. Circ Physiol, vol. 289, pp. 501–512, 2005. [281] H. Takaoka, G. Esposito, L. Mao, et al. “Heart size-independent analysis of myocardial function in murine pressure overload hypertrophy,” Am. J. Physiol. - Hear. Circ. Physiol., vol. 282, no. 6 51-6, pp. 2190-7, 2002. [282] K. Tobita and B. B. Keller, “End-systolic myocardial stiffness is a load-independent index of contractility in stage 24 chick embryonic heart.,” Am. J. Physiol., vol. 276, no. 6, pp. 2102-8, 1999. [283] Z. Keshavarz-Motamed, J. Garcia, E. Gaillard et al. “Non-Invasive Determination of Left Ventricular Workload in Patients with Aortic Stenosis Using Magnetic Resonance Imaging and Doppler Echocardiography,” PLoS One, vol. 9, no. 1, p. e86793, 2014. [284] C. J. O’Sullivan, E. Spitzer, D. Heg et al. “Effect of resting heart rate on two-year clinical outcomes of high-risk patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation,” EuroIntervention, vol. 12, no. 4, pp. 490–498, 2016. [285] D. Zhang, X. Shen, and X. Qi, “Resting heart rate and all-cause and cardiovascular mortality in the general population: a meta-analysis,” Can. Med. Assoc. J., vol. 188, no. 3, pp. E53–E63, 2016. [286] J. L. Vukasovic, F. Florenzano, P. Adriazola, and E. Escobar. “Heart rate variability in severe aortic stenosis.,” J. Heart Valve Dis., vol. 8, no. 2, pp. 143–8, 1999. [287] J. H. Spühler, J. Jansson, N. Jansson, and J. Hoffman, “3D fluid-structure interaction simulation of aortic valves using a unified continuum ALE FEM model,” Front. Physiol., vol. 9, 2018. [288] M. Enriquez-Sarano and C. Tribouilloy, “Quantitation of mitral regurgitation: Rationale, approach, and interpretation in clinical practice,” Heart, vol. 88, no. suppl. 4., pp. iv1–iv3, 2002. [289] P. A. Grayburn, N. J. Weissman, and J. L. Zamorano. “Quantitation of mitral regurgitation,” Circulation, vol. 126, no. 16. pp. 2005–2017, 2012. [290] F. Helvacioglu, O. Yildirimturk, C. Duran et al. “The evaluation of mitral valve stenosis: comparison of transthoracic echocardiography and cardiac magnetic resonance.,” Eur. Heart J. Cardiovasc. Imaging, vol. 15, no. 2, pp. 164–9, Feb. 2014. [291] D. R. Warriner, M. Bayley, Y. Shi, et al. “Computer model for the cardiovascular system: Development of an e-learning tool for teaching of medical students,” BMC Med. Educ., vol. 17, no. 1, 2017."],"dcterms:accessrights":["public"],"dc:title":["Computational Modelling in the Management of Patients with Aortic Valve Stenosis"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000318017161"]},"updated_at":"2026-11-18T22:41:35Z"}