{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:29197"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:29197","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Energy Efficient Composable Data Centres","abstract":"There is a proliferation of the number of operational data centres (DCs) across the globe to meet present and future demands for on-demand computational offerings. In spite of the many efforts to improve the utilisation and power efficiency of traditional DCs, results achieved remain sub-optimal. This is primarily because of the rigid utilisation boundaries of traditional server architecture. Disaggregation of server resource components and dynamic orchestration of such resources over a suitable network has been proposed to improve efficiency of next generation composable DCs. This thesis conducts a study on the best setup for such composable DC infrastructure to achieve optimal energy efficiency. First, we formulate a mixed integer linear programming (MILP) model to investigate the optimal scale and scope of resource disaggregation for energy efficient composable DCs. Concurrently, we also investigate the most suitable network for optimal energy efficiency. By placing CPU and memory intensive workloads energy efficiently in different composable DCs, we found that implementing logical disaggregation at rack-scale in composable DCs that adopt all-optical network enables optimal energy efficiency. Physical resource disaggregation of traditional DC servers at rack-scale leads to up to 8% and 20% savings in overall power consumption when CPU intensive and memory intensive workloads are provisioned respectively. We also found that adoption of micro-service architecture in conjunction with the logical disaggregation and rack-scale resource disaggregation can further improve efficiency in composable DCs. A combination of disaggregation and micro-services enabled optimal resources utilisation and energy efficiencies. Thus, relative to the traditional DC up to 23% reduction in the total power consumption is achieved by combining both approaches. Secondly, we describe two variants of a practical and scalable network for composable DC that leverages optical technologies and techniques. Additionally, we formulate a MILP model to evaluate the performance of the novel network in rack-scale composable DCs that implement different forms of disaggregation. The electrical-optical variant of the novel topology achieves similar performance as a reference network while utilising fewer transceivers per compute node. The targeted adoption of optical technologies by both variants of the proposed network achieves greater (4 - 5 times greater) utilisation of available network throughput than the reference network which implemented a generic design. Furthermore, we also formulate a MILP model and develop a comparable heuristic to study the benefits of adopting server disaggregation in the fog computing tier. We evaluate the energy efficient placement of interactive apps in a future fog 6G network in our study. Relative to the present practice of deploying traditional servers in the fog computing layer, adoption of disaggregated servers reduces total fog computing power consumption by up to 18% when a network with low delay penalty is considered. Finally, we recommend that logical disaggregation and rack-scale disaggregation should be implemented in composable DCs that desire energy efficiency. This is because of the advantages and flexibility that both approaches jointly offer as reported in this thesis. We also recommend the targeted use of optical network technologies and techniques. Relative to a general-purposed design, this provides a more efficient approach to mitigate network challenges of composable DCs. Furthermore, these recommendations should be extended to the fog computing tier and edge of future networks to enable greater energy efficiency of the cloud-of-things architecture.","abstract_html":"There is a proliferation of the number of operational data centres (DCs) across the globe to meet present and future demands for on-demand computational offerings. In spite of the many efforts to improve the utilisation and power efficiency of traditional DCs, results achieved remain sub-optimal. This is primarily because of the rigid utilisation boundaries of traditional server architecture. Disaggregation of server resource components and dynamic orchestration of such resources over a suitable network has been proposed to improve efficiency of next generation composable DCs. This thesis conducts a study on the best setup for such composable DC infrastructure to achieve optimal energy efficiency. First, we formulate a mixed integer linear programming (MILP) model to investigate the optimal scale and scope of resource disaggregation for energy efficient composable DCs. Concurrently, we also investigate the most suitable network for optimal energy efficiency. By placing CPU and memory intensive workloads energy efficiently in different composable DCs, we found that implementing logical disaggregation at rack-scale in composable DCs that adopt all-optical network enables optimal energy efficiency. Physical resource disaggregation of traditional DC servers at rack-scale leads to up to 8% and 20% savings in overall power consumption when CPU intensive and memory intensive workloads are provisioned respectively. We also found that adoption of micro-service architecture in conjunction with the logical disaggregation and rack-scale resource disaggregation can further improve efficiency in composable DCs. A combination of disaggregation and micro-services enabled optimal resources utilisation and energy efficiencies. Thus, relative to the traditional DC up to 23% reduction in the total power consumption is achieved by combining both approaches. Secondly, we describe two variants of a practical and scalable network for composable DC that leverages optical technologies and techniques. Additionally, we formulate a MILP model to evaluate the performance of the novel network in rack-scale composable DCs that implement different forms of disaggregation. The electrical-optical variant of the novel topology achieves similar performance as a reference network while utilising fewer transceivers per compute node. The targeted adoption of optical technologies by both variants of the proposed network achieves greater (4 - 5 times greater) utilisation of available network throughput than the reference network which implemented a generic design. Furthermore, we also formulate a MILP model and develop a comparable heuristic to study the benefits of adopting server disaggregation in the fog computing tier. We evaluate the energy efficient placement of interactive apps in a future fog 6G network in our study. Relative to the present practice of deploying traditional servers in the fog computing layer, adoption of disaggregated servers reduces total fog computing power consumption by up to 18% when a network with low delay penalty is considered. Finally, we recommend that logical disaggregation and rack-scale disaggregation should be implemented in composable DCs that desire energy efficiency. This is because of the advantages and flexibility that both approaches jointly offer as reported in this thesis. We also recommend the targeted use of optical network technologies and techniques. Relative to a general-purposed design, this provides a more efficient approach to mitigate network challenges of composable DCs. Furthermore, these recommendations should be extended to the fog computing tier and edge of future networks to enable greater energy efficiency of the cloud-of-things architecture.","abstract_has_math":false,"creators":["Ajibola, Opeyemi Oluwaseyi"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Elmirghani, Jaafar Mohamed Hashim","El-Gorashi, Taisir E. H."],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-03","date_published":"2021-03","updated_at":"2026-11-18T22:43:01Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/H040536/1","EP/K016873/1","EP/S016570/1"],"render_values":[{"text":"EP/H040536/1","href":null,"code":true},{"text":"EP/K016873/1","href":null,"code":true},{"text":"EP/S016570/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000252684358"],"render_values":[{"text":"0000-0002-5268-4358","href":"https://orcid.org/0000-0002-5268-4358","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/29197/1/Energy%20Efficient%20Composable%20Data%20Centres.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A29197","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Elmirghani, Jaafar Mohamed Hashim","El-Gorashi, Taisir E. H."]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Petroleum Technology Trust Fund (PTDF)","INTelligent Energy aware NETworks (INTERNET)","SwiTching And tRansmission (STAR)","Terabit Bidirectional Multi-user Optical Wireless System (TOWS) project"]},{"key":"dc:creator","label":"Author","values":["Ajibola, Opeyemi Oluwaseyi"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000252684358"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-03"]},{"key":"dc:date.issued","label":"Date","values":["2021-03"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Faculty of Engineering (Leeds)","School of Electronic & Electrical Engineering (Leeds)","Institute of Integrated Information Systems (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/29197/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] LogicMonitor Inc, “Cloud Vision 2020: The Future of Cloud,” 2017. [Online]. Available: https://www.logicmonitor.com/wp-content/uploads/2017/12/LogicMonitor-Cloud-2020-The-Future-of-the-Cloud.pdf. [Accessed: 17-Jun-2019]. [2] IDC, “IDC Forecasts Worldwide Technology Spending on the Internet of Things to Reach $1.2 Trillion in 2022,” 2018. [Online]. Available: https://www.idc.com/getdoc.jsp?containerId=prUS43994118. [Accessed: 17-Jun-2019]. [3] Cisco, “Internet of Things,” 2016. [Online]. Available: www.cisco.com/go/iot. [Accessed: 17-Jun-2019]. [4] Cisco, “Cisco Global Cloud Index: Forecast and Methodology, 2015–2020,” Cisco Global Cloud Index, 2016. [Online]. Available: http://www.cisco.com/c/dam/en/us/solutions/collateral/service-provider/global-cloud-index-gci/white-paper-c11-738085.pdf. [Accessed: 15-May-2017]. [5] M. Satyanarayanan, P. Bahl, R. Caceres, and N. Davies, “The Case for VM-Based Cloudlets in Mobile Computing,” IEEE Pervasive Comput., vol. 8, no. 4, pp. 14–23, 2009. [6] F. Bonomi, R. Milito, J. Zhu, and S. Addepalli, “Fog Computing and Its Role in the Internet of Things,” in Proceedings of the First Edition of the MCC Workshop on Mobile Cloud Computing, 2012, pp. 13–16. [7] F. Bonomi, R. Milito, P. Natarajan, and J. Zhu, “‘Fog Computing: A Platform for Internet of Things and Analytics’ Flavio Bonomi, Rodolfo Milito, Preethi Natarajan and Jiang Zhu, N. Bessis and C. Dobre (eds.), Big Data and Internet of Things: 169 A Roadmap for Smart Environments, Studies in Computational,” 2014. [8] M. Aazam, S. Zeadally, and K. A. Harras, “Fog Computing Architecture, Evaluation, and Future Research Directions,” IEEE Commun. Mag., vol. 56, no. 5, pp. 46–52, 2018. [9] Y. Yang, “FA2ST: Fog as a Service Technology,” in 2017 IEEE 41st Annual Computer Software and Applications Conference (COMPSAC), 2017, vol. 1, p. 708. [10] W. Li et al., “System modelling and performance evaluation of a three-tier Cloud of Things,” Futur. Gener. Comput. Syst., vol. 70, pp. 104–125, 2017. [11] Cisco, “Fog Computing and the Internet of Things: Extend the Cloud to Where the Things Are What You Will Learn,” 2015. [12] A. Yousefpour, G. Ishigaki, R. Gour, and J. P. Jue, “On Reducing IoT Service Delay via Fog Offloading,” IEEE Internet Things J., vol. 5, no. 2, pp. 998–1010, 2018. [13] J. Taylor, “Facebook’s data center infrastructure: Open compute, disaggregated rack, and beyond,” 2015 Optical Fiber Communications Conference and Exhibition (OFC). p. 1, 2015. [14] A. D. Papaioannou, R. Nejabati, and D. Simeonidou, “The Benefits of a Disaggregated Data Centre: A Resource Allocation Approach,” 2016 IEEE Global Communications Conference (GLOBECOM). pp. 1–7, 2016. [15] B. Abali, R. J. Eickemeyer, H. Franke, C.-S. Li, and M. Taubenblatt, “Disaggregated and optically interconnected memory: when will it be cost effective?,” CoRR, vol. abs/1503.0, 2015. [16] H. M. Mohammad Ali, T. E. H. El-Gorashi, A. Q. Lawey, and J. M. H. Elmirghani, “Future Energy Efficient Data Centers With Disaggregated Servers,” J. Light. Technol., vol. 35, no. 24, pp. 5361–5380, 2017. [17] R. Lin, Y. Cheng, M. De Andrade, L. Wosinska, and J. Chen, “Disaggregated Data Centers: Challenges and Trade-offs,” IEEE Commun. Mag., vol. 58, no. 2, pp. 20–26, Feb. 2020. [18] C. Kachris and I. Tomkos, “A Survey on Optical Interconnects for Data Centers,” vol. 14, no. 4, pp. 1021–1036, 2012. [19] C. Guo, H. Wu, K. Tan, L. Shi, Y. Zhang, and S. Lu, “DCell: A Scalable and Fault-Tolerant Network Structure for Data Centers,” in SIGCOMM08, 2008. [20] T. Benson, A. Akella, and D. A. Maltz, “Network Traffic Characteristics of Data Centers in the Wild,” in Proceedings of the 10th ACM SIGCOMM Conference on Internet Measurement, 2010, pp. 267–280. [21] A. Greenberg, J. Hamilton, D. A. Maltz, and P. Patel, “The Cost of a Cloud: Research Problems in Data Center Networks,” SIGCOMM Comput. Commun. Rev., vol. 39, no. 1, pp. 68–73, Dec. 2008. [22] M. Al-Fares, A. Loukissas, and A. Vahdat, “A scalable, commodity data center network architecture,” in Computer Communication Review, 2008, vol. 38, no. 4, pp. 63–74. [23] N. Farrington and A. Andreyev, “Facebook’s data center network architecture,” 2013 Opt. Interconnects Conf., pp. 49–50, 2013. [24] Cisco, “Cisco Data Center Spine-and-Leaf Architecture: Design Overview White Paper - Cisco,” 2016. [Online]. Available: http://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-series-switches/white-paper-c11-737022.html. [Accessed: 14-Feb-2017]. [25] R. Sohan, A. Rice, W. M. Andrew, and K. Mansley, “Characterizing 10 Gbps network interface energy consumption,” in IEEE Local Computer Network Conference, 2010, pp. 268–271. [26] C. Guo et al., “BCube: A High Performance, Server-centric Network Architecture for Modular Data Centers,” in ACM SIGCOMM, 2009, pp. 63–74. [27] D. Li, C. Guo, H. Wu, K. Tan, Y. Zhang, and S. Lu, “FiConn : Using Backup Port for Server Interconnection in Data Centers,” pp. 2276–2285, 2009. [28] G. Wang et al., “C-Through: Part-Time Optics in Data Centers,” Proc. ACM SIGCOMM 2010 Conf., vol. 40, no. 4, pp. 327–338, Aug. 2010. [29] N. Farrington et al., “Helios: A Hybrid Electrical/Optical Switch Architecture for Modular Data Centers,” in Proceedings of the ACM SIGCOMM 2010 Conference, 2010, pp. 339–350. [30] K. Chen et al., “OSA: An Optical Switching Architecture for Data Center Networks With Unprecedented Flexibility,” IEEE/ACM Trans. Netw., vol. 22, no. 2, pp. 498–511, Apr. 2014. [31] G. M. Saridis et al., “Lightness: A Function-Virtualizable Software Defined Data Center Network With All-Optical Circuit/Packet Switching,” Journal of Lightwave Technology, vol. 34, no. 7. pp. 1618–1627, 2016. [32] X. Ye, P. Mejia, Y. Yin, R. Proietti, S. J. B. Yoo, and V. Akella, “DOS - A scalable optical switch for datacenters,” 2010 ACM/IEEE Symposium on Architectures for Networking and Communications Systems (ANCS). pp. 1–12, 2010. [33] A. A. Hammadi, “Future PON Data Centre Networks,” University of Leeds, Leeds, United Kingdom, 2016. [34] A. Roozbeh et al., “Software-Defined ‘Hardware’ Infrastructures: A Survey on Enabling Technologies and Open Research Directions,” IEEE Commun. Surv. Tutorials, pp. 1–1, 2018. [35] IBM Cloud Education, “Containerization,” 15-May-2019. [Online]. Available: https://www.ibm.com/cloud/learn/containerization. [Accessed: 19-Jul-2020]. [36] Kubernetes, “What is Kubernetes?” [Online]. Available: https://kubernetes.io/docs/concepts/overview/what-is-kubernetes/. [Accessed: 19-Jul-2020]. [37] Microsoft, “Introduction to microservices on Azure | Microsoft Docs.” [Online]. Available: https://docs.microsoft.com/en-us/azure/service-fabric/service-fabric-overview-microservices. [Accessed: 22-Apr-2018]. [38] J. Lewis and M. Fowler, “Microservices,” 2014. [Online]. Available: https://martinfowler.com/articles/microservices.html. [Accessed: 03-Sep-2017]. [39] A. Balalaie, A. Heydarnoori, and P. Jamshidi, “Migrating to Cloud-Native Architectures Using Microservices: An Experience Report,” in Advances in Service-Oriented and Cloud Computing: Workshops of ESOCC 2015, Taormina, Italy, September 15-17, 2015, Revised Selected Papers, A. Celesti and P. Leitner, Eds. Cham: Springer International Publishing, 2016, pp. 201–215. [40] R. V. Shahir Daya Nguyen Van Duy, Kameswara Eati, Carlos M Ferreira, Dejan Glozic, Vasfi Gucer, Manav Gupta, Sunil Joshi, Valerie Lampkin, Marcelo martins, Shishir Narain, Microservices from Theory to Practice Creating Applications in IBM Bluemix Using the Microservices Approach, First. IBM Redbooks, 2015. [41] A. Sill, “The Design and Architecture of Microservices,” IEEE Cloud Comput., vol. 3, no. 5, pp. 76–80, 2016. [42] S. Miniman, “The Data Center: Past, Present And Future,” 06-Feb-2014. [Online]. Available: http://wikibon.org/wiki/v/The_Data_Center:_Past,_Present_and_Future. [Accessed: 17-Jul-2020]. [43] Amazon Web Services, “Serverless Computing.” [Online]. Available: https://aws.amazon.com/serverless/. [Accessed: 19-Jul-2020]. [44] Microsoft Azure, “Serverless computing .” [Online]. Available: https://azure.microsoft.com/en-gb/overview/serverless-computing/. [Accessed: 19-Jul-2020]. [45] Google Cloud, “Serverless computing.” [Online]. Available: https://cloud.google.com/serverless. [Accessed: 19-Jul-2020]. [46] Google Cloud, “What Is Serverless Architecture, and How Does It Help My Business?” [Online]. Available: https://lp.google-mkto.com/rs/248-TPC-286/images/GC-Article-What-Is-Serverless.pdf?utm_campaign=2016-gc-cnc-nurture-email-other-a3-vpinfra-infra&utm_source=nurture&utm_medium=emailinfra3-3b&gcpngmt=infra&cntctg=awrns&mkt_tok=eyJpIjoiWkRsaU0yUTNaamRtTXpkbS. [Accessed: 05-Sep-2018]. [47] M. Roberts, “Serverless Architectures,” 22-May-2018. [Online]. Available: https://martinfowler.com/articles/serverless.html. [Accessed: 19-Jul-2020]. [48] A. Andrae and T. Edler, “On Global Electricity Usage of Communication Technology: Trends to 2030,” Challenges, vol. 6, no. 1, pp. 117–157, Apr. 2015. [49] Facebook, “Designing a Very Efficient Data Center,” 14-Apr-2011. [Online]. Available: https://www.facebook.com/notes/facebook-engineering/designing-a-very-efficient-data-center/10150148003778920/. [Accessed: 20-Jul-2020]. [50] Google, “Machine learning finds new ways for our data centers to save energy.” [Online]. Available: https://sustainability.google/projects/machine-learning/. [Accessed: 20-Jul-2020]. [51] Open Compute Project, “About.” [Online]. Available: https://www.opencompute.org/about. [Accessed: 20-Jul-2020]. [52] Facebook, “Building Efficient Data Centers with the Open Compute Project,” 07-Apr-2011. [Online]. Available: https://www.facebook.com/note.php?note_id=10150144039563920. [Accessed: 20-Jul-2020]. [53] Intel Corporation, “Intel® Rack Scale Design Is Now Ready for Open Source Development - IT Peer Network,” 2016. [Online]. Available: https://itpeernetwork.intel.com/intel-rack-scale-design-now-ready-open-source-development/. [Accessed: 15-May-2017]. [54] Intel, “Intel® RSD Partners.” [Online]. Available: https://www.intel.com/content/www/us/en/architecture-and-technology/rack-scale-design/rack-scale-design-partners.html. [Accessed: 20-Jul-2020]. [55] European Telecommunications Standards Institute, “Network Functions Virtualization,” 2018. [Online]. Available: www.etsi.org. [Accessed: 29-Mar-2019]. [56] Facebook, “On Our Way to Lower Emissions and 100% Renewable Energy,” 28-Aug-2018. [Online]. Available: https://about.fb.com/news/2018/08/renewable-energy/. [Accessed: 20-Jul-2020]. [57] Google, “Google Environmental Report 2018,” 2018. [58] Urs Hölzle and Google, “Announcing ‘round-the-clock clean energy for cloud,” 14-Sep-2020. [Online]. Available: https://cloud.google.com/blog/topics/inside-google-cloud/announcing-round-the-clock-clean-energy-for-cloud. [Accessed: 20-Sep-2020]. [59] B. Abali, R. J. Eickemeyer, H. Franke, C.-S. Li, and M. A. Taubenblatt, “Disaggregated and optically interconnected memory: when will it be cost effective?,” Mar. 2015. [60] A. Pagès, J. Perelló, F. Agraz, and S. Spadaro, “Optimal VDC Service Provisioning in Optically Interconnected Disaggregated Data Centers,” IEEE Communications Letters, vol. 20, no. 7. pp. 1353–1356, 2016. [61] K. Katrinis et al., “Rack-scale disaggregated cloud data centers: The dReDBox project vision,” 2016 Design, Automation & Test in Europe Conference & Exhibition (DATE). pp. 690–695, 2016. [62] C.-S. Li, H. Franke, C. Parris, B. Abali, M. Kesavan, and V. Chang, “Composable architecture for rack scale big data computing,” Futur. Gener. Comput. Syst., vol. 67, pp. 180–193, 2017. [63] R. F. Freitas and W. W. Wilcke, “Storage-class memory: The next storage system technology,” IBM Journal of Research and Development, vol. 52, no. 4.5. pp. 439–447, 2008. [64] J. Zheng and H. T. Mouftah, Optical WDM Networks: Concepts and Design Principles, 1st ed. John Wiley & Sons, 2004. [65] D. Sadot and E. Boimovich, “Tunable optical filters for dense WDM networks,” IEEE Commun. Mag., vol. 36, no. 12, pp. 50–55, Dec. 1998. [66] F. Hillier and G. Lieberman, Introduction to operations research, 9th ed. New York: McGraw-Hill, 2010. [67] M. Pioro and D. Medhi, Routing, Flow, and Capacity Design in Communication and Computer Networks, Morgan Kaufmann Publishers, 2004., 1st ed. Morgan Kaufmann, 2004. [68] AMPL Optimization inc, “AMPL.” [Online]. Available: https://ampl.com/products/ampl/. [Accessed: 23-Aug-2020]. [69] AMPL Optimization inc, “CPLEX for AMPL.” [Online]. Available: https://ampl.com/products/solvers/solvers-we-sell/cplex/. [Accessed: 23-Aug-2020]. [70] University of Leeds, “ARC3 – Advanced Research Computing.” [Online]. Available: http://arc.leeds.ac.uk/systems/arc3/. [Accessed: 11-Sep-2018]. [71] A. P. Engelbrecht, Computational Intelligence: An Introduction, 2nd ed. Wiley Publishing, 2007. [72] J. Kennedy, R. C. Eberhart, and Y. Shi, Swarm Intelligence. San Francisco: Elsevier, 2001. [73] M. Dorigo and T. Stützle, Ant Colony Optimization. Cambridge: MIT Press, 2004. [74] G. Kandiraju, H. Franke, M. D. Williams, M. Steinder, and S. M. Black, “Software defined infrastructures,” IBM J. Res. Dev., vol. 58, no. 2/3, pp. 2:1-2:13, Mar. 2014. [75] A. Rickman, “The commercialization of silicon photonics,” Nat Phot., vol. 8, no. 8, pp. 579–582, Aug. 2014. [76] D. Thomson et al., “Roadmap on silicon photonics,” J. Opt., vol. 18, no. 7, p. 073003, Jul. 2016. [77] Ericsson, “Hyperscale Cloud – reimagining data centers from hardware to applications,” 2016. [Online]. Available: https://www.ericsson.com/assets/local/publications/white-papers/wp-hyperscale-cloud.pdf. [Accessed: 19-May-2017]. [78] P. Costa, H. Ballani, and D. Narayanan, “Rethinking the Network Stack for Rack-scale Computers,” in 6th {USENIX} Workshop on Hot Topics in Cloud Computing (HotCloud 14), 2014. [79] S. J. Ben YOO, “The Role of Photonics in Future Computing and Data Centers,” IEICE Trans. Commun., vol. E97.B, no. 7, pp. 1272–1280, 2014. [80] E. Agrell et al., “Roadmap of optical communications,” J. Opt., vol. 18, no. 6, pp. 0–40, Jun. 2016. [81] Intel, “Intel® Rack Scale Design.” [Online]. Available: https://www.intel.com/content/www/us/en/architecture-and-technology/rack-scale-design-overview.html. [Accessed: 30-May-2018]. [82] Gen-Z Consortium, “About – Gen-Z Consortium.” [Online]. Available: https://genzconsortium.org/about/. [Accessed: 11-May-2018]. [83] Hewlett Packard Enterprise, “HPE Composable Infrastructure: Bridging traditional IT and the idea economy | HPETM United Kingdom.” [Online]. Available: https://www.hpe.com/uk/en/pdfViewer.html?resource=/content/hpe/country/uk/en/resources/solutions/white-paper/4aa5-8813enw&parentPage=/uk/en/what-is/composable-infrastructure. [Accessed: 05-Jan-2018]. [84] Todd Brannon, “Composable Infrastructure, Part 3: ‘What is it??,’” 2015. [Online]. Available: https://blogs.cisco.com/datacenter/composable-infrastructure-part-3-what-is-it. [Accessed: 11-Jan-2018]. [85] Intel, “Intel® Rack Scale Design Architecture Specification,” 2017. [Online]. Available: https://www.intel.com/content/dam/www/public/us/en/documents/guides/platform-hardware-design-guide-v2-1.pdf. [Accessed: 01-Jun-2018]. [86] Huawei, “High Throughput Computing Data Center Architecture (Thinking of Data Center 3.0).” [Online]. Available: http://www.huawei.com/ilink/en/download/HW_349607&usg=AFQjCNE0m-KD71dxJeRf1cJSkNaJbpNgnw&cad=rja. [Accessed: 13-Sep-2017]. [87] G. Saridis et al., “DORIOS: Demonstration of an All-Optical Distributed CPU, Memory, Storage Intra DCN Interconnect,” Opt. Fiber Commun. Conf., p. W1D.2, 2015. [88] G. M. Saridis et al., “EVROS: All-optical programmable disaggregated data centre interconnect utilizing hollow-core bandgap fibre,” 2015 European Conference on Optical Communication (ECOC). pp. 1–3, 2015. [89] Y. Yan et al., “All-Optical Programmable Disaggregated Data Centre Network Realized by FPGA-Based Switch and Interface Card,” J. Light. Technol., vol. 34, no. 8, pp. 1925–1932, 2016. [90] Gen-Z Consortium, “What are the key technical advantages of Gen-Z?” [Online]. Available: https://genzconsortium.org/faqs/. [Accessed: 31-Aug-2018]. [91] I. C. Bulent and A. Paul, “Towards a Composable Computer System,” in Proceedings of the International Conference on High Performance Computing in Asia-Pacific Region, 2018, pp. 137–147. [92] G. Zervas, H. Yuan, A. Saljoghei, Q. Chen, and V. Mishra, “Optically disaggregated data centers with minimal remote memory latency: Technologies, architectures, and resource allocation [Invited],” IEEE/OSA J. Opt. Commun. Netw., vol. 10, no. 2, pp. A270–A285, 2018. [93] Y. Yan, Y. Shu, G. M. Saridis, B. R. Rofoee, G. Zervas, and D. Simeonidou, “FPGA-based optical programmable switch and interface card for disaggregated OPS/OCS data centre networks,” in 2015 European Conference on Optical Communication (ECOC), 2015, pp. 1–3. [94] H. M. Mohammad Ali, T. E. H. El-Gorashi, A. Q. Lawey, and J. M. H. Elmirghani, “Future Energy Efficient Data Centers With Disaggregated Servers,” J. Light. Technol., vol. 35, no. 24, pp. 5361–5380, 2017. [95] K. Christodoulopoulos, K. Kontodimas, A. Siokis, K. Yiannopoulos, and E. Varvarigos, “Efficient Bandwidth Allocation in the NEPHELE Optical/Electrical Datacenter Interconnect,” J. Opt. Commun. Netw., vol. 9, no. 12, p. 1145, Dec. 2017. [96] Ericsson, “Ericsson Hyperscale Datacenter System 8000 Solution Brief,” 2016. [Online]. Available: https://www.ericsson.com/globalassets/pdfs/solution_brief_hds_8000_final.pdf. [Accessed: 19-May-2017]. [97] G. Zervas et al., “Disaggregated compute, memory and network systems: A new era for optical data centre architectures,” in 2017 Optical Fiber Communications Conference and Exhibition (OFC), 2017, pp. 1–3. [98] G. Farias, F. Brasileiro, R. Lopes, M. Carvalho, F. Morais, and D. Turull, “On the Efficiency Gains of Using Disaggregated Hardware to Build Warehouse-Scale Clusters,” in Proceedings of the International Conference on Cloud Computing Technology and Science, CloudCom, 2017, vol. 2017-Decem, pp. 239–246. [99] H. M. Mohammad Ali et al., “Energy efficient disaggregated servers for future data centers,” in 2015 20th European Conference on Networks and Optical Communications - (NOC), 2015, pp. 1–6. [100] H. M. M. Ali, A. M. Al-Salim, A. Q. Lawey, T. El-Gorashi, and J. M. H. Elmirghani, “Energy efficient resource provisioning with VM migration heuristic for Disaggregated Server design,” 2016 18th International Conference on Transparent Optical Networks (ICTON). pp. 1–5, 2016. [101] PolettiF. et al., “Towards high-capacity fibre-optic communications at the speed of light in vacuum,” Nat Phot., vol. 7, no. 4, pp. 279–284, Apr. 2013. [102] A. Beloglazov, R. Buyya, Y. C. Lee, and A. Zomaya, “A Taxonomy and Survey of Energy-Efficient Data Centers and Cloud Computing Systems,” Adv. Comput., vol. 82, pp. 47–111, Jan. 2011. [103] Cisco, “Cisco Nexus 3132C-Z Switches Data Sheet - Cisco.” [Online]. Available: https://www.cisco.com/c/en/us/products/collateral/switches/nexus-3000-series-switches/datasheet-c78-740895.html. [Accessed: 22-Oct-2018]. [104] Finisar Corporation, “WaveShaper-16000S-Product-Brief.” [Online]. Available: www.finisar.com/instruments. [Accessed: 07-Sep-2018]. [105] Polatis, “Polatis - Series 6000 single mode all optical low loss switch 4x4 to 192x192 ports.” [Online]. Available: http://www.polatis.com/polatis-series-6000-optical-matrix-switch-192x192-sdn-enabled-industry-leading-performace-lowest-loss-switches.asp. [Accessed: 07-Sep-2018]. [106] P. X. Gao et al., “Network Requirements for Resource Disaggregation,” in Proceedings of the 12th USENIX Conference on Operating Systems Design and Implementation, 2016, pp. 249–264. [107] R. Lin et al., “Real-time 100 Gbps/λ/core NRZ and EDB IM/DD transmission over multicore fiber for intra-datacenter communication networks,” Opt. Express, vol. 26, no. 8, p. 10519, Apr. 2018. [108] X. Pang et al., “200 Gbps/Lane IM/DD Technologies for Short Reach Optical Interconnects,” J. Light. Technol., vol. 38, no. 2, pp. 492–503, Jan. 2020. [109] Q. Cheng, A. Wonfor, J. L. Wei, R. V Penty, and I. H. White, “Low-energy, high-performance lossless 8×8 SOA switch,” in 2015 Optical Fiber Communications Conference and Exhibition (OFC), 2015, pp. 1–3. [110] H. A. Alharbi, T. E. H. Elgorashi, and J. M. H. Elmirghani, “Energy efficient virtual machines placement over cloud-fog network architecture,” IEEE Access, vol. 8, pp. 94697–94718, 2020. [111] I. S. B. M. Isa, T. E. H. El-Gorashi, M. O. I. Musa, and J. M. H. Elmirghani, “Energy efficient fog-based healthcare monitoring infrastructure,” IEEE Access, vol. 8, pp. 197828–197852, 2020. [112] B. A. Yosuf, M. Musa, T. Elgorashi, and J. Elmirghani, “Energy Efficient Distributed Processing for IoT,” IEEE Access, vol. 8, pp. 161080–161108, 2020. [113] Cisco, “Application hosting on Catalyst 9000 series of switches - Cisco DevNet.” [Online]. Available: https://developer.cisco.com/docs/app-hosting/#!application-hosting-in-the-enterprise/what-is-application-hosting. [Accessed: 21-Apr-2020]. [114] K. David, J. Elmirghani, H. Haas, and X. H. You, “Defining 6G: Challenges and Opportunities [From the Guest Editors],” IEEE Vehicular Technology Magazine, vol. 14, no. 3. Institute of Electrical and Electronics Engineers Inc., pp. 14–16, 01-Sep-2019. [115] S. Sarkar, S. Chatterjee, and S. Misra, “Assessment of the Suitability of Fog Computing in the Context of Internet of Things,” IEEE Trans. Cloud Comput., vol. 6, no. 1, pp. 46–59, 2018. [116] R. Deng, R. Lu, C. Lai, and T. H. Luan, “Towards power consumption-delay tradeoff by workload allocation in cloud-fog computing,” in 2015 IEEE International Conference on Communications (ICC), 2015, pp. 3909–3914. [117] A. N. Al-Quzweeni, A. Q. Lawey, T. E. H. Elgorashi, and J. M. H. Elmirghani, “Optimized Energy Aware 5G Network Function Virtualization,” IEEE Access, vol. 7, pp. 44939–44958, 2019. [118] N. Chen, Y. Yang, T. Zhang, M. Zhou, X. Luo, and J. K. Zao, “Fog as a Service Technology,” IEEE Commun. Mag., vol. 56, no. 11, pp. 95–101, 2018. [119] M. Chiang and T. Zhang, “Fog and IoT: An Overview of Research Opportunities,” IEEE Internet Things J., vol. 3, no. 6, pp. 854–864, 2016. [120] K. Hong, D. Lillethun, U. Ramachandran, B. Ottenwälder, and B. Koldehofe, “Mobile Fog: A Programming Model for Large-scale Applications on the Internet of Things,” in Proceedings of the Second ACM SIGCOMM Workshop on Mobile Cloud Computing, 2013, pp. 15–20. [121] A. Yousefpour, G. Ishigaki, and J. P. Jue, “Fog Computing: Towards Minimizing Delay in the Internet of Things,” in 2017 IEEE International Conference on Edge Computing (EDGE), 2017, pp. 17–24. [122] R. Deng, R. Lu, C. Lai, T. H. Luan, and H. Liang, “Optimal Workload Allocation in Fog-Cloud Computing Toward Balanced Delay and Power Consumption,” IEEE Internet Things J., vol. 3, no. 6, pp. 1171–1181, 2016. [123] Juniper Networks, “NFX SERIES NETWORK SERVICES PLATFORM.” [Online]. Available: https://www.juniper.net/assets/uk/en/local/pdf/datasheets/1000563-en.pdf. [Accessed: 28-Mar-2019]. [124] Juniper Networks, “MX Series 5G Universal Routing Platforms Product Description.” [Online]. Available: https://www.juniper.net/assets/uk/en/local/pdf/datasheets/1000597-en.pdf. [Accessed: 28-Mar-2019]. [125] Cisco, “Cisco ME 4600 Series Optical Network Terminal Data Sheet - Cisco,” 2017. [Online]. Available: https://www.cisco.com/c/en/us/products/collateral/switches/me-4600-series-multiservice-optical-access-platform/datasheet-c78-730446.html. [Accessed: 28-Mar-2019]."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/H040536/1","EP/K016873/1","EP/S016570/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/29197/1/Energy%20Efficient%20Composable%20Data%20Centres.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["There is a proliferation of the number of operational data centres (DCs) across the globe to meet present and future demands for on-demand computational offerings. In spite of the many efforts to improve the utilisation and power efficiency of traditional DCs, results achieved remain sub-optimal. This is primarily because of the rigid utilisation boundaries of traditional server architecture. Disaggregation of server resource components and dynamic orchestration of such resources over a suitable network has been proposed to improve efficiency of next generation composable DCs. This thesis conducts a study on the best setup for such composable DC infrastructure to achieve optimal energy efficiency. First, we formulate a mixed integer linear programming (MILP) model to investigate the optimal scale and scope of resource disaggregation for energy efficient composable DCs. Concurrently, we also investigate the most suitable network for optimal energy efficiency. By placing CPU and memory intensive workloads energy efficiently in different composable DCs, we found that implementing logical disaggregation at rack-scale in composable DCs that adopt all-optical network enables optimal energy efficiency. Physical resource disaggregation of traditional DC servers at rack-scale leads to up to 8% and 20% savings in overall power consumption when CPU intensive and memory intensive workloads are provisioned respectively. We also found that adoption of micro-service architecture in conjunction with the logical disaggregation and rack-scale resource disaggregation can further improve efficiency in composable DCs. A combination of disaggregation and micro-services enabled optimal resources utilisation and energy efficiencies. Thus, relative to the traditional DC up to 23% reduction in the total power consumption is achieved by combining both approaches. Secondly, we describe two variants of a practical and scalable network for composable DC that leverages optical technologies and techniques. Additionally, we formulate a MILP model to evaluate the performance of the novel network in rack-scale composable DCs that implement different forms of disaggregation. The electrical-optical variant of the novel topology achieves similar performance as a reference network while utilising fewer transceivers per compute node. The targeted adoption of optical technologies by both variants of the proposed network achieves greater (4 - 5 times greater) utilisation of available network throughput than the reference network which implemented a generic design. Furthermore, we also formulate a MILP model and develop a comparable heuristic to study the benefits of adopting server disaggregation in the fog computing tier. We evaluate the energy efficient placement of interactive apps in a future fog 6G network in our study. Relative to the present practice of deploying traditional servers in the fog computing layer, adoption of disaggregated servers reduces total fog computing power consumption by up to 18% when a network with low delay penalty is considered. Finally, we recommend that logical disaggregation and rack-scale disaggregation should be implemented in composable DCs that desire energy efficiency. This is because of the advantages and flexibility that both approaches jointly offer as reported in this thesis. We also recommend the targeted use of optical network technologies and techniques. Relative to a general-purposed design, this provides a more efficient approach to mitigate network challenges of composable DCs. Furthermore, these recommendations should be extended to the fog computing tier and edge of future networks to enable greater energy efficiency of the cloud-of-things architecture."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Energy Efficient Composable Data Centres"]}]}],"canonical_facts":{"dc:contributor.advisor":["Elmirghani, Jaafar Mohamed Hashim","El-Gorashi, Taisir E. H."],"dc:contributor.sponsor":["Petroleum Technology Trust Fund (PTDF)","INTelligent Energy aware NETworks (INTERNET)","SwiTching And tRansmission (STAR)","Terabit Bidirectional Multi-user Optical Wireless System (TOWS) project"],"dc:creator":["Ajibola, Opeyemi Oluwaseyi"],"dc:date":["2021-03"],"dc:date.issued":["2021-03"],"dc:description.abstract":["There is a proliferation of the number of operational data centres (DCs) across the globe to meet present and future demands for on-demand computational offerings. In spite of the many efforts to improve the utilisation and power efficiency of traditional DCs, results achieved remain sub-optimal. This is primarily because of the rigid utilisation boundaries of traditional server architecture. Disaggregation of server resource components and dynamic orchestration of such resources over a suitable network has been proposed to improve efficiency of next generation composable DCs. This thesis conducts a study on the best setup for such composable DC infrastructure to achieve optimal energy efficiency. First, we formulate a mixed integer linear programming (MILP) model to investigate the optimal scale and scope of resource disaggregation for energy efficient composable DCs. Concurrently, we also investigate the most suitable network for optimal energy efficiency. By placing CPU and memory intensive workloads energy efficiently in different composable DCs, we found that implementing logical disaggregation at rack-scale in composable DCs that adopt all-optical network enables optimal energy efficiency. Physical resource disaggregation of traditional DC servers at rack-scale leads to up to 8% and 20% savings in overall power consumption when CPU intensive and memory intensive workloads are provisioned respectively. We also found that adoption of micro-service architecture in conjunction with the logical disaggregation and rack-scale resource disaggregation can further improve efficiency in composable DCs. A combination of disaggregation and micro-services enabled optimal resources utilisation and energy efficiencies. Thus, relative to the traditional DC up to 23% reduction in the total power consumption is achieved by combining both approaches. Secondly, we describe two variants of a practical and scalable network for composable DC that leverages optical technologies and techniques. Additionally, we formulate a MILP model to evaluate the performance of the novel network in rack-scale composable DCs that implement different forms of disaggregation. The electrical-optical variant of the novel topology achieves similar performance as a reference network while utilising fewer transceivers per compute node. The targeted adoption of optical technologies by both variants of the proposed network achieves greater (4 - 5 times greater) utilisation of available network throughput than the reference network which implemented a generic design. Furthermore, we also formulate a MILP model and develop a comparable heuristic to study the benefits of adopting server disaggregation in the fog computing tier. We evaluate the energy efficient placement of interactive apps in a future fog 6G network in our study. Relative to the present practice of deploying traditional servers in the fog computing layer, adoption of disaggregated servers reduces total fog computing power consumption by up to 18% when a network with low delay penalty is considered. Finally, we recommend that logical disaggregation and rack-scale disaggregation should be implemented in composable DCs that desire energy efficiency. This is because of the advantages and flexibility that both approaches jointly offer as reported in this thesis. We also recommend the targeted use of optical network technologies and techniques. Relative to a general-purposed design, this provides a more efficient approach to mitigate network challenges of composable DCs. Furthermore, these recommendations should be extended to the fog computing tier and edge of future networks to enable greater energy efficiency of the cloud-of-things architecture."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/H040536/1","EP/K016873/1","EP/S016570/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/29197/1/Energy%20Efficient%20Composable%20Data%20Centres.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Faculty of Engineering (Leeds)","School of Electronic & Electrical Engineering (Leeds)","Institute of Integrated Information Systems (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/29197/"],"dc:relation.references":["[1] LogicMonitor Inc, “Cloud Vision 2020: The Future of Cloud,” 2017. [Online]. Available: https://www.logicmonitor.com/wp-content/uploads/2017/12/LogicMonitor-Cloud-2020-The-Future-of-the-Cloud.pdf. [Accessed: 17-Jun-2019]. [2] IDC, “IDC Forecasts Worldwide Technology Spending on the Internet of Things to Reach $1.2 Trillion in 2022,” 2018. [Online]. Available: https://www.idc.com/getdoc.jsp?containerId=prUS43994118. [Accessed: 17-Jun-2019]. [3] Cisco, “Internet of Things,” 2016. [Online]. Available: www.cisco.com/go/iot. [Accessed: 17-Jun-2019]. [4] Cisco, “Cisco Global Cloud Index: Forecast and Methodology, 2015–2020,” Cisco Global Cloud Index, 2016. [Online]. Available: http://www.cisco.com/c/dam/en/us/solutions/collateral/service-provider/global-cloud-index-gci/white-paper-c11-738085.pdf. [Accessed: 15-May-2017]. [5] M. Satyanarayanan, P. Bahl, R. Caceres, and N. Davies, “The Case for VM-Based Cloudlets in Mobile Computing,” IEEE Pervasive Comput., vol. 8, no. 4, pp. 14–23, 2009. [6] F. Bonomi, R. Milito, J. Zhu, and S. Addepalli, “Fog Computing and Its Role in the Internet of Things,” in Proceedings of the First Edition of the MCC Workshop on Mobile Cloud Computing, 2012, pp. 13–16. [7] F. Bonomi, R. Milito, P. Natarajan, and J. Zhu, “‘Fog Computing: A Platform for Internet of Things and Analytics’ Flavio Bonomi, Rodolfo Milito, Preethi Natarajan and Jiang Zhu, N. Bessis and C. Dobre (eds.), Big Data and Internet of Things: 169 A Roadmap for Smart Environments, Studies in Computational,” 2014. [8] M. Aazam, S. Zeadally, and K. A. Harras, “Fog Computing Architecture, Evaluation, and Future Research Directions,” IEEE Commun. Mag., vol. 56, no. 5, pp. 46–52, 2018. [9] Y. Yang, “FA2ST: Fog as a Service Technology,” in 2017 IEEE 41st Annual Computer Software and Applications Conference (COMPSAC), 2017, vol. 1, p. 708. [10] W. Li et al., “System modelling and performance evaluation of a three-tier Cloud of Things,” Futur. Gener. Comput. Syst., vol. 70, pp. 104–125, 2017. [11] Cisco, “Fog Computing and the Internet of Things: Extend the Cloud to Where the Things Are What You Will Learn,” 2015. [12] A. Yousefpour, G. Ishigaki, R. Gour, and J. P. Jue, “On Reducing IoT Service Delay via Fog Offloading,” IEEE Internet Things J., vol. 5, no. 2, pp. 998–1010, 2018. [13] J. Taylor, “Facebook’s data center infrastructure: Open compute, disaggregated rack, and beyond,” 2015 Optical Fiber Communications Conference and Exhibition (OFC). p. 1, 2015. [14] A. D. Papaioannou, R. Nejabati, and D. Simeonidou, “The Benefits of a Disaggregated Data Centre: A Resource Allocation Approach,” 2016 IEEE Global Communications Conference (GLOBECOM). pp. 1–7, 2016. [15] B. Abali, R. J. Eickemeyer, H. Franke, C.-S. Li, and M. Taubenblatt, “Disaggregated and optically interconnected memory: when will it be cost effective?,” CoRR, vol. abs/1503.0, 2015. [16] H. M. Mohammad Ali, T. E. H. El-Gorashi, A. Q. Lawey, and J. M. H. Elmirghani, “Future Energy Efficient Data Centers With Disaggregated Servers,” J. Light. Technol., vol. 35, no. 24, pp. 5361–5380, 2017. [17] R. Lin, Y. Cheng, M. De Andrade, L. Wosinska, and J. Chen, “Disaggregated Data Centers: Challenges and Trade-offs,” IEEE Commun. Mag., vol. 58, no. 2, pp. 20–26, Feb. 2020. [18] C. Kachris and I. Tomkos, “A Survey on Optical Interconnects for Data Centers,” vol. 14, no. 4, pp. 1021–1036, 2012. [19] C. Guo, H. Wu, K. Tan, L. Shi, Y. Zhang, and S. Lu, “DCell: A Scalable and Fault-Tolerant Network Structure for Data Centers,” in SIGCOMM08, 2008. [20] T. Benson, A. Akella, and D. A. Maltz, “Network Traffic Characteristics of Data Centers in the Wild,” in Proceedings of the 10th ACM SIGCOMM Conference on Internet Measurement, 2010, pp. 267–280. [21] A. Greenberg, J. Hamilton, D. A. Maltz, and P. Patel, “The Cost of a Cloud: Research Problems in Data Center Networks,” SIGCOMM Comput. Commun. Rev., vol. 39, no. 1, pp. 68–73, Dec. 2008. [22] M. Al-Fares, A. Loukissas, and A. Vahdat, “A scalable, commodity data center network architecture,” in Computer Communication Review, 2008, vol. 38, no. 4, pp. 63–74. [23] N. Farrington and A. Andreyev, “Facebook’s data center network architecture,” 2013 Opt. Interconnects Conf., pp. 49–50, 2013. [24] Cisco, “Cisco Data Center Spine-and-Leaf Architecture: Design Overview White Paper - Cisco,” 2016. [Online]. Available: http://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-series-switches/white-paper-c11-737022.html. [Accessed: 14-Feb-2017]. [25] R. Sohan, A. Rice, W. M. Andrew, and K. Mansley, “Characterizing 10 Gbps network interface energy consumption,” in IEEE Local Computer Network Conference, 2010, pp. 268–271. [26] C. Guo et al., “BCube: A High Performance, Server-centric Network Architecture for Modular Data Centers,” in ACM SIGCOMM, 2009, pp. 63–74. [27] D. Li, C. Guo, H. Wu, K. Tan, Y. Zhang, and S. Lu, “FiConn : Using Backup Port for Server Interconnection in Data Centers,” pp. 2276–2285, 2009. [28] G. Wang et al., “C-Through: Part-Time Optics in Data Centers,” Proc. ACM SIGCOMM 2010 Conf., vol. 40, no. 4, pp. 327–338, Aug. 2010. [29] N. Farrington et al., “Helios: A Hybrid Electrical/Optical Switch Architecture for Modular Data Centers,” in Proceedings of the ACM SIGCOMM 2010 Conference, 2010, pp. 339–350. [30] K. Chen et al., “OSA: An Optical Switching Architecture for Data Center Networks With Unprecedented Flexibility,” IEEE/ACM Trans. Netw., vol. 22, no. 2, pp. 498–511, Apr. 2014. [31] G. M. Saridis et al., “Lightness: A Function-Virtualizable Software Defined Data Center Network With All-Optical Circuit/Packet Switching,” Journal of Lightwave Technology, vol. 34, no. 7. pp. 1618–1627, 2016. [32] X. Ye, P. Mejia, Y. Yin, R. Proietti, S. J. B. Yoo, and V. Akella, “DOS - A scalable optical switch for datacenters,” 2010 ACM/IEEE Symposium on Architectures for Networking and Communications Systems (ANCS). pp. 1–12, 2010. [33] A. A. Hammadi, “Future PON Data Centre Networks,” University of Leeds, Leeds, United Kingdom, 2016. [34] A. Roozbeh et al., “Software-Defined ‘Hardware’ Infrastructures: A Survey on Enabling Technologies and Open Research Directions,” IEEE Commun. Surv. Tutorials, pp. 1–1, 2018. [35] IBM Cloud Education, “Containerization,” 15-May-2019. [Online]. Available: https://www.ibm.com/cloud/learn/containerization. [Accessed: 19-Jul-2020]. [36] Kubernetes, “What is Kubernetes?” [Online]. Available: https://kubernetes.io/docs/concepts/overview/what-is-kubernetes/. [Accessed: 19-Jul-2020]. [37] Microsoft, “Introduction to microservices on Azure | Microsoft Docs.” [Online]. Available: https://docs.microsoft.com/en-us/azure/service-fabric/service-fabric-overview-microservices. [Accessed: 22-Apr-2018]. [38] J. Lewis and M. Fowler, “Microservices,” 2014. [Online]. Available: https://martinfowler.com/articles/microservices.html. [Accessed: 03-Sep-2017]. [39] A. Balalaie, A. Heydarnoori, and P. Jamshidi, “Migrating to Cloud-Native Architectures Using Microservices: An Experience Report,” in Advances in Service-Oriented and Cloud Computing: Workshops of ESOCC 2015, Taormina, Italy, September 15-17, 2015, Revised Selected Papers, A. Celesti and P. Leitner, Eds. Cham: Springer International Publishing, 2016, pp. 201–215. [40] R. V. Shahir Daya Nguyen Van Duy, Kameswara Eati, Carlos M Ferreira, Dejan Glozic, Vasfi Gucer, Manav Gupta, Sunil Joshi, Valerie Lampkin, Marcelo martins, Shishir Narain, Microservices from Theory to Practice Creating Applications in IBM Bluemix Using the Microservices Approach, First. IBM Redbooks, 2015. [41] A. Sill, “The Design and Architecture of Microservices,” IEEE Cloud Comput., vol. 3, no. 5, pp. 76–80, 2016. [42] S. Miniman, “The Data Center: Past, Present And Future,” 06-Feb-2014. [Online]. Available: http://wikibon.org/wiki/v/The_Data_Center:_Past,_Present_and_Future. [Accessed: 17-Jul-2020]. [43] Amazon Web Services, “Serverless Computing.” [Online]. Available: https://aws.amazon.com/serverless/. [Accessed: 19-Jul-2020]. [44] Microsoft Azure, “Serverless computing .” [Online]. Available: https://azure.microsoft.com/en-gb/overview/serverless-computing/. [Accessed: 19-Jul-2020]. [45] Google Cloud, “Serverless computing.” [Online]. Available: https://cloud.google.com/serverless. [Accessed: 19-Jul-2020]. [46] Google Cloud, “What Is Serverless Architecture, and How Does It Help My Business?” [Online]. Available: https://lp.google-mkto.com/rs/248-TPC-286/images/GC-Article-What-Is-Serverless.pdf?utm_campaign=2016-gc-cnc-nurture-email-other-a3-vpinfra-infra&utm_source=nurture&utm_medium=emailinfra3-3b&gcpngmt=infra&cntctg=awrns&mkt_tok=eyJpIjoiWkRsaU0yUTNaamRtTXpkbS. [Accessed: 05-Sep-2018]. [47] M. Roberts, “Serverless Architectures,” 22-May-2018. [Online]. Available: https://martinfowler.com/articles/serverless.html. [Accessed: 19-Jul-2020]. [48] A. Andrae and T. Edler, “On Global Electricity Usage of Communication Technology: Trends to 2030,” Challenges, vol. 6, no. 1, pp. 117–157, Apr. 2015. [49] Facebook, “Designing a Very Efficient Data Center,” 14-Apr-2011. [Online]. Available: https://www.facebook.com/notes/facebook-engineering/designing-a-very-efficient-data-center/10150148003778920/. [Accessed: 20-Jul-2020]. [50] Google, “Machine learning finds new ways for our data centers to save energy.” [Online]. Available: https://sustainability.google/projects/machine-learning/. [Accessed: 20-Jul-2020]. [51] Open Compute Project, “About.” [Online]. Available: https://www.opencompute.org/about. [Accessed: 20-Jul-2020]. [52] Facebook, “Building Efficient Data Centers with the Open Compute Project,” 07-Apr-2011. [Online]. Available: https://www.facebook.com/note.php?note_id=10150144039563920. [Accessed: 20-Jul-2020]. [53] Intel Corporation, “Intel® Rack Scale Design Is Now Ready for Open Source Development - IT Peer Network,” 2016. [Online]. Available: https://itpeernetwork.intel.com/intel-rack-scale-design-now-ready-open-source-development/. [Accessed: 15-May-2017]. [54] Intel, “Intel® RSD Partners.” [Online]. Available: https://www.intel.com/content/www/us/en/architecture-and-technology/rack-scale-design/rack-scale-design-partners.html. [Accessed: 20-Jul-2020]. [55] European Telecommunications Standards Institute, “Network Functions Virtualization,” 2018. [Online]. Available: www.etsi.org. [Accessed: 29-Mar-2019]. [56] Facebook, “On Our Way to Lower Emissions and 100% Renewable Energy,” 28-Aug-2018. [Online]. Available: https://about.fb.com/news/2018/08/renewable-energy/. [Accessed: 20-Jul-2020]. [57] Google, “Google Environmental Report 2018,” 2018. [58] Urs Hölzle and Google, “Announcing ‘round-the-clock clean energy for cloud,” 14-Sep-2020. [Online]. Available: https://cloud.google.com/blog/topics/inside-google-cloud/announcing-round-the-clock-clean-energy-for-cloud. [Accessed: 20-Sep-2020]. [59] B. Abali, R. J. Eickemeyer, H. Franke, C.-S. Li, and M. A. Taubenblatt, “Disaggregated and optically interconnected memory: when will it be cost effective?,” Mar. 2015. [60] A. Pagès, J. Perelló, F. Agraz, and S. Spadaro, “Optimal VDC Service Provisioning in Optically Interconnected Disaggregated Data Centers,” IEEE Communications Letters, vol. 20, no. 7. pp. 1353–1356, 2016. [61] K. Katrinis et al., “Rack-scale disaggregated cloud data centers: The dReDBox project vision,” 2016 Design, Automation & Test in Europe Conference & Exhibition (DATE). pp. 690–695, 2016. [62] C.-S. Li, H. Franke, C. Parris, B. Abali, M. Kesavan, and V. Chang, “Composable architecture for rack scale big data computing,” Futur. Gener. Comput. Syst., vol. 67, pp. 180–193, 2017. [63] R. F. Freitas and W. W. Wilcke, “Storage-class memory: The next storage system technology,” IBM Journal of Research and Development, vol. 52, no. 4.5. pp. 439–447, 2008. [64] J. Zheng and H. T. Mouftah, Optical WDM Networks: Concepts and Design Principles, 1st ed. John Wiley & Sons, 2004. [65] D. Sadot and E. Boimovich, “Tunable optical filters for dense WDM networks,” IEEE Commun. Mag., vol. 36, no. 12, pp. 50–55, Dec. 1998. [66] F. Hillier and G. Lieberman, Introduction to operations research, 9th ed. New York: McGraw-Hill, 2010. [67] M. Pioro and D. Medhi, Routing, Flow, and Capacity Design in Communication and Computer Networks, Morgan Kaufmann Publishers, 2004., 1st ed. Morgan Kaufmann, 2004. [68] AMPL Optimization inc, “AMPL.” [Online]. Available: https://ampl.com/products/ampl/. [Accessed: 23-Aug-2020]. [69] AMPL Optimization inc, “CPLEX for AMPL.” [Online]. Available: https://ampl.com/products/solvers/solvers-we-sell/cplex/. [Accessed: 23-Aug-2020]. [70] University of Leeds, “ARC3 – Advanced Research Computing.” [Online]. Available: http://arc.leeds.ac.uk/systems/arc3/. [Accessed: 11-Sep-2018]. [71] A. P. Engelbrecht, Computational Intelligence: An Introduction, 2nd ed. Wiley Publishing, 2007. [72] J. Kennedy, R. C. Eberhart, and Y. Shi, Swarm Intelligence. San Francisco: Elsevier, 2001. [73] M. Dorigo and T. Stützle, Ant Colony Optimization. Cambridge: MIT Press, 2004. [74] G. Kandiraju, H. Franke, M. D. Williams, M. Steinder, and S. M. Black, “Software defined infrastructures,” IBM J. Res. Dev., vol. 58, no. 2/3, pp. 2:1-2:13, Mar. 2014. [75] A. Rickman, “The commercialization of silicon photonics,” Nat Phot., vol. 8, no. 8, pp. 579–582, Aug. 2014. [76] D. Thomson et al., “Roadmap on silicon photonics,” J. Opt., vol. 18, no. 7, p. 073003, Jul. 2016. [77] Ericsson, “Hyperscale Cloud – reimagining data centers from hardware to applications,” 2016. [Online]. Available: https://www.ericsson.com/assets/local/publications/white-papers/wp-hyperscale-cloud.pdf. [Accessed: 19-May-2017]. [78] P. Costa, H. Ballani, and D. Narayanan, “Rethinking the Network Stack for Rack-scale Computers,” in 6th {USENIX} Workshop on Hot Topics in Cloud Computing (HotCloud 14), 2014. [79] S. J. Ben YOO, “The Role of Photonics in Future Computing and Data Centers,” IEICE Trans. Commun., vol. E97.B, no. 7, pp. 1272–1280, 2014. [80] E. Agrell et al., “Roadmap of optical communications,” J. Opt., vol. 18, no. 6, pp. 0–40, Jun. 2016. [81] Intel, “Intel® Rack Scale Design.” [Online]. Available: https://www.intel.com/content/www/us/en/architecture-and-technology/rack-scale-design-overview.html. [Accessed: 30-May-2018]. [82] Gen-Z Consortium, “About – Gen-Z Consortium.” [Online]. Available: https://genzconsortium.org/about/. [Accessed: 11-May-2018]. [83] Hewlett Packard Enterprise, “HPE Composable Infrastructure: Bridging traditional IT and the idea economy | HPETM United Kingdom.” [Online]. Available: https://www.hpe.com/uk/en/pdfViewer.html?resource=/content/hpe/country/uk/en/resources/solutions/white-paper/4aa5-8813enw&parentPage=/uk/en/what-is/composable-infrastructure. [Accessed: 05-Jan-2018]. [84] Todd Brannon, “Composable Infrastructure, Part 3: ‘What is it??,’” 2015. [Online]. Available: https://blogs.cisco.com/datacenter/composable-infrastructure-part-3-what-is-it. [Accessed: 11-Jan-2018]. [85] Intel, “Intel® Rack Scale Design Architecture Specification,” 2017. [Online]. Available: https://www.intel.com/content/dam/www/public/us/en/documents/guides/platform-hardware-design-guide-v2-1.pdf. [Accessed: 01-Jun-2018]. [86] Huawei, “High Throughput Computing Data Center Architecture (Thinking of Data Center 3.0).” [Online]. Available: http://www.huawei.com/ilink/en/download/HW_349607&usg=AFQjCNE0m-KD71dxJeRf1cJSkNaJbpNgnw&cad=rja. [Accessed: 13-Sep-2017]. [87] G. Saridis et al., “DORIOS: Demonstration of an All-Optical Distributed CPU, Memory, Storage Intra DCN Interconnect,” Opt. Fiber Commun. Conf., p. W1D.2, 2015. [88] G. M. Saridis et al., “EVROS: All-optical programmable disaggregated data centre interconnect utilizing hollow-core bandgap fibre,” 2015 European Conference on Optical Communication (ECOC). pp. 1–3, 2015. [89] Y. Yan et al., “All-Optical Programmable Disaggregated Data Centre Network Realized by FPGA-Based Switch and Interface Card,” J. Light. Technol., vol. 34, no. 8, pp. 1925–1932, 2016. [90] Gen-Z Consortium, “What are the key technical advantages of Gen-Z?” [Online]. Available: https://genzconsortium.org/faqs/. [Accessed: 31-Aug-2018]. [91] I. C. Bulent and A. Paul, “Towards a Composable Computer System,” in Proceedings of the International Conference on High Performance Computing in Asia-Pacific Region, 2018, pp. 137–147. [92] G. Zervas, H. Yuan, A. Saljoghei, Q. Chen, and V. Mishra, “Optically disaggregated data centers with minimal remote memory latency: Technologies, architectures, and resource allocation [Invited],” IEEE/OSA J. Opt. Commun. Netw., vol. 10, no. 2, pp. A270–A285, 2018. [93] Y. Yan, Y. Shu, G. M. Saridis, B. R. Rofoee, G. Zervas, and D. Simeonidou, “FPGA-based optical programmable switch and interface card for disaggregated OPS/OCS data centre networks,” in 2015 European Conference on Optical Communication (ECOC), 2015, pp. 1–3. [94] H. M. Mohammad Ali, T. E. H. El-Gorashi, A. Q. Lawey, and J. M. H. Elmirghani, “Future Energy Efficient Data Centers With Disaggregated Servers,” J. Light. Technol., vol. 35, no. 24, pp. 5361–5380, 2017. [95] K. Christodoulopoulos, K. Kontodimas, A. Siokis, K. Yiannopoulos, and E. Varvarigos, “Efficient Bandwidth Allocation in the NEPHELE Optical/Electrical Datacenter Interconnect,” J. Opt. Commun. Netw., vol. 9, no. 12, p. 1145, Dec. 2017. [96] Ericsson, “Ericsson Hyperscale Datacenter System 8000 Solution Brief,” 2016. [Online]. Available: https://www.ericsson.com/globalassets/pdfs/solution_brief_hds_8000_final.pdf. [Accessed: 19-May-2017]. [97] G. Zervas et al., “Disaggregated compute, memory and network systems: A new era for optical data centre architectures,” in 2017 Optical Fiber Communications Conference and Exhibition (OFC), 2017, pp. 1–3. [98] G. Farias, F. Brasileiro, R. Lopes, M. Carvalho, F. Morais, and D. Turull, “On the Efficiency Gains of Using Disaggregated Hardware to Build Warehouse-Scale Clusters,” in Proceedings of the International Conference on Cloud Computing Technology and Science, CloudCom, 2017, vol. 2017-Decem, pp. 239–246. [99] H. M. Mohammad Ali et al., “Energy efficient disaggregated servers for future data centers,” in 2015 20th European Conference on Networks and Optical Communications - (NOC), 2015, pp. 1–6. [100] H. M. M. Ali, A. M. Al-Salim, A. Q. Lawey, T. El-Gorashi, and J. M. H. Elmirghani, “Energy efficient resource provisioning with VM migration heuristic for Disaggregated Server design,” 2016 18th International Conference on Transparent Optical Networks (ICTON). pp. 1–5, 2016. [101] PolettiF. et al., “Towards high-capacity fibre-optic communications at the speed of light in vacuum,” Nat Phot., vol. 7, no. 4, pp. 279–284, Apr. 2013. [102] A. Beloglazov, R. Buyya, Y. C. Lee, and A. Zomaya, “A Taxonomy and Survey of Energy-Efficient Data Centers and Cloud Computing Systems,” Adv. Comput., vol. 82, pp. 47–111, Jan. 2011. [103] Cisco, “Cisco Nexus 3132C-Z Switches Data Sheet - Cisco.” [Online]. Available: https://www.cisco.com/c/en/us/products/collateral/switches/nexus-3000-series-switches/datasheet-c78-740895.html. [Accessed: 22-Oct-2018]. [104] Finisar Corporation, “WaveShaper-16000S-Product-Brief.” [Online]. Available: www.finisar.com/instruments. [Accessed: 07-Sep-2018]. [105] Polatis, “Polatis - Series 6000 single mode all optical low loss switch 4x4 to 192x192 ports.” [Online]. Available: http://www.polatis.com/polatis-series-6000-optical-matrix-switch-192x192-sdn-enabled-industry-leading-performace-lowest-loss-switches.asp. [Accessed: 07-Sep-2018]. [106] P. X. Gao et al., “Network Requirements for Resource Disaggregation,” in Proceedings of the 12th USENIX Conference on Operating Systems Design and Implementation, 2016, pp. 249–264. [107] R. Lin et al., “Real-time 100 Gbps/λ/core NRZ and EDB IM/DD transmission over multicore fiber for intra-datacenter communication networks,” Opt. Express, vol. 26, no. 8, p. 10519, Apr. 2018. [108] X. Pang et al., “200 Gbps/Lane IM/DD Technologies for Short Reach Optical Interconnects,” J. Light. Technol., vol. 38, no. 2, pp. 492–503, Jan. 2020. [109] Q. Cheng, A. Wonfor, J. L. Wei, R. V Penty, and I. H. White, “Low-energy, high-performance lossless 8×8 SOA switch,” in 2015 Optical Fiber Communications Conference and Exhibition (OFC), 2015, pp. 1–3. [110] H. A. Alharbi, T. E. H. Elgorashi, and J. M. H. Elmirghani, “Energy efficient virtual machines placement over cloud-fog network architecture,” IEEE Access, vol. 8, pp. 94697–94718, 2020. [111] I. S. B. M. Isa, T. E. H. El-Gorashi, M. O. I. Musa, and J. M. H. Elmirghani, “Energy efficient fog-based healthcare monitoring infrastructure,” IEEE Access, vol. 8, pp. 197828–197852, 2020. [112] B. A. Yosuf, M. Musa, T. Elgorashi, and J. Elmirghani, “Energy Efficient Distributed Processing for IoT,” IEEE Access, vol. 8, pp. 161080–161108, 2020. [113] Cisco, “Application hosting on Catalyst 9000 series of switches - Cisco DevNet.” [Online]. Available: https://developer.cisco.com/docs/app-hosting/#!application-hosting-in-the-enterprise/what-is-application-hosting. [Accessed: 21-Apr-2020]. [114] K. David, J. Elmirghani, H. Haas, and X. H. You, “Defining 6G: Challenges and Opportunities [From the Guest Editors],” IEEE Vehicular Technology Magazine, vol. 14, no. 3. Institute of Electrical and Electronics Engineers Inc., pp. 14–16, 01-Sep-2019. [115] S. Sarkar, S. Chatterjee, and S. Misra, “Assessment of the Suitability of Fog Computing in the Context of Internet of Things,” IEEE Trans. Cloud Comput., vol. 6, no. 1, pp. 46–59, 2018. [116] R. Deng, R. Lu, C. Lai, and T. H. Luan, “Towards power consumption-delay tradeoff by workload allocation in cloud-fog computing,” in 2015 IEEE International Conference on Communications (ICC), 2015, pp. 3909–3914. [117] A. N. Al-Quzweeni, A. Q. Lawey, T. E. H. Elgorashi, and J. M. H. Elmirghani, “Optimized Energy Aware 5G Network Function Virtualization,” IEEE Access, vol. 7, pp. 44939–44958, 2019. [118] N. Chen, Y. Yang, T. Zhang, M. Zhou, X. Luo, and J. K. Zao, “Fog as a Service Technology,” IEEE Commun. Mag., vol. 56, no. 11, pp. 95–101, 2018. [119] M. Chiang and T. Zhang, “Fog and IoT: An Overview of Research Opportunities,” IEEE Internet Things J., vol. 3, no. 6, pp. 854–864, 2016. [120] K. Hong, D. Lillethun, U. Ramachandran, B. Ottenwälder, and B. Koldehofe, “Mobile Fog: A Programming Model for Large-scale Applications on the Internet of Things,” in Proceedings of the Second ACM SIGCOMM Workshop on Mobile Cloud Computing, 2013, pp. 15–20. [121] A. Yousefpour, G. Ishigaki, and J. P. Jue, “Fog Computing: Towards Minimizing Delay in the Internet of Things,” in 2017 IEEE International Conference on Edge Computing (EDGE), 2017, pp. 17–24. [122] R. Deng, R. Lu, C. Lai, T. H. Luan, and H. Liang, “Optimal Workload Allocation in Fog-Cloud Computing Toward Balanced Delay and Power Consumption,” IEEE Internet Things J., vol. 3, no. 6, pp. 1171–1181, 2016. [123] Juniper Networks, “NFX SERIES NETWORK SERVICES PLATFORM.” [Online]. Available: https://www.juniper.net/assets/uk/en/local/pdf/datasheets/1000563-en.pdf. [Accessed: 28-Mar-2019]. [124] Juniper Networks, “MX Series 5G Universal Routing Platforms Product Description.” [Online]. Available: https://www.juniper.net/assets/uk/en/local/pdf/datasheets/1000597-en.pdf. [Accessed: 28-Mar-2019]. [125] Cisco, “Cisco ME 4600 Series Optical Network Terminal Data Sheet - Cisco,” 2017. [Online]. Available: https://www.cisco.com/c/en/us/products/collateral/switches/me-4600-series-multiservice-optical-access-platform/datasheet-c78-730446.html. [Accessed: 28-Mar-2019]."],"dcterms:accessrights":["public"],"dc:title":["Energy Efficient Composable Data Centres"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000252684358"]},"updated_at":"2026-11-18T22:43:01Z"}