{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:29324"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:29324","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Tribocorrosion and tribochemistry of cobalt-chromium alloy used for total hip replacement","abstract":"Cobalt-based metallic biomaterials are mostly employed as bearing materials for Total Hip Replacement (THR) owing to their high strength, their biocompatibility, as well as their wear and fatigue resistance. Cobalt-chromium-molybdenum (CoCrMo) alloys also have excellent passivity characteristics as an oxide layer can form on the surface spontaneously, reducing corrosion. Nevertheless, mechanical interaction, such as friction and wear, can damage the passive oxide layer and also causes metal products used in such replacements to be released into the human body. The repeated removal of the oxide layer due to joint articulation leads to wear and corrosion; a process termed ‘tribocorrosion’. Due to the complex working environment, as well as the presence of organic elements or species, there remains a lack of knowledge regarding tribocorrosion and the surface film mechanisms. An understanding upon these mechanisms is important since studies have reported that the tribochemical film, a complex metal-protein compound, can enhance the surface protection towards tribocorrosive processes. However, the behaviour is still debatable depending on the working conditions (e.g. temperature, pH, contact load and organic species in the lubricant). The fundamental mechanisms of wear and corrosion are recognised to solve the longevity problem of the orthopaedic implants. Tribocorrosion and tribochemistry of CoCrMo alloys were investigated in various conditions. A reciprocating tribometer, electrochemical cells and surface analysis techniques were employed to observe the tribocorrosive behaviour of CoCrMo samples tested in protein-containing electrolytes. Conditions were applied to investigate various protein-metal interactions regarding behaviour in the tribocorrosion process: (a) in a range of electrochemical potential, (b) with different organic species, (c) protein conditions and (d) with the addition of metal ions in the bulk electrolytes. Results highlighted that a tribocorrosion and tribochemical reactions occurred during sliding are sensitive to the electrolyte composition. These findings contribute to the pre-clinical understanding of protein-metal interactions occurring in tribofilms’ formation and the system variables effect on the metallic bearing surfaces.","abstract_html":"Cobalt-based metallic biomaterials are mostly employed as bearing materials for Total Hip Replacement (THR) owing to their high strength, their biocompatibility, as well as their wear and fatigue resistance. Cobalt-chromium-molybdenum (CoCrMo) alloys also have excellent passivity characteristics as an oxide layer can form on the surface spontaneously, reducing corrosion. Nevertheless, mechanical interaction, such as friction and wear, can damage the passive oxide layer and also causes metal products used in such replacements to be released into the human body. The repeated removal of the oxide layer due to joint articulation leads to wear and corrosion; a process termed ‘tribocorrosion’. Due to the complex working environment, as well as the presence of organic elements or species, there remains a lack of knowledge regarding tribocorrosion and the surface film mechanisms. An understanding upon these mechanisms is important since studies have reported that the tribochemical film, a complex metal-protein compound, can enhance the surface protection towards tribocorrosive processes. However, the behaviour is still debatable depending on the working conditions (e.g. temperature, pH, contact load and organic species in the lubricant). The fundamental mechanisms of wear and corrosion are recognised to solve the longevity problem of the orthopaedic implants. Tribocorrosion and tribochemistry of CoCrMo alloys were investigated in various conditions. A reciprocating tribometer, electrochemical cells and surface analysis techniques were employed to observe the tribocorrosive behaviour of CoCrMo samples tested in protein-containing electrolytes. Conditions were applied to investigate various protein-metal interactions regarding behaviour in the tribocorrosion process: (a) in a range of electrochemical potential, (b) with different organic species, (c) protein conditions and (d) with the addition of metal ions in the bulk electrolytes. Results highlighted that a tribocorrosion and tribochemical reactions occurred during sliding are sensitive to the electrolyte composition. These findings contribute to the pre-clinical understanding of protein-metal interactions occurring in tribofilms’ formation and the system variables effect on the metallic bearing surfaces.","abstract_has_math":false,"creators":["Taufiqurrakhman, Mohamad"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Bryant, Michael"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-05","date_published":"2021-05","updated_at":"2026-11-18T22:43:31Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.837091"],"render_values":[{"text":"uk.bl.ethos.837091","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000284624798"],"render_values":[{"text":"0000-0002-8462-4798","href":"https://orcid.org/0000-0002-8462-4798","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/29324/1/Taufiqurrakhman_M_MechanicalEng_PhD_2021.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A29324","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bryant, Michael"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Indonesia Endowment Fund for Education (LPDP)"]},{"key":"dc:creator","label":"Author","values":["Taufiqurrakhman, Mohamad"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000284624798"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-05"]},{"key":"dc:date.issued","label":"Date","values":["2021-05"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Mechanical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/29324/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. Taufiqurrakhman, M., M. Bryant, and A. Neville, Tribofilms on CoCrMo alloys: Understanding the role of the lubricant. Biotribology, 2019: p. 100104. 2. Hip Replacement. 2019 [cited 2020 30 September]; Available from: https://www.nhs.uk/conditions/hip-replacement/. 3. OECD, Hip and knee replacement. 2017. 4. Jared R. H. Foran, M., FAAOS. Total Hip Replacement. OrthoInfo 2020 June [cited 2020 1 October 2020]; Available from: https://orthoinfo.aaos.org/en/treatment/total-hip-replacement. 5. National Joint Registry 17th Annual Report 2020. 2020, National Joint Registry. 6. Grigoris, P., P. Roberts, and K. Panousis, The development of the DuromTM metal-on-metal hip resurfacing. Hip Int, 2006. 16 Suppl 4: p. 65-72. 7. Drummond, J., P. Tran, and C. Fary, Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management. Journal of functional biomaterials, 2015. 6(3): p. 486-499. 8. Yan, Y., et al., Tribofilm formation in biotribocorrosion – does it regulate ion release in metal-on-metal artificial hip joints? Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2010. 224(9): p. 997-1006. 9. Fan, J., et al., Synovial fluid lubrication of artificial joints: protein film formation and composition. Faraday Discussions, 2012. 156: p. 69-85. 10. Hesketh, J., et al., The composition of tribofilms produced on metal-on-metal hip bearings. Biomaterials, 2014. 35(7): p. 2113-2119. 11. Espallargas, N., et al., In-situ generated tribomaterial in metal/metal contacts: Current understanding and future implications for implants. Biotribology, 2017. 10(Supplement C): p. 42-50. 12. Liao, Y., et al., Graphitic Tribological Layers in Metal-on-Metal Hip Replacements. Science, 2011. 334(6063): p. 1687-1690. 13. Liao, Y., et al., CoCrMo Metal-on-Metal Hip Replacements. Physical chemistry chemical physics : PCCP, 2013. 15(3): p. 10.1039/c2cp42968c. 14. Williams, D.F., Definitions in biomaterials. 1987, Amsterdam: Elsevier. 72. 15. Ghalme, S., A. Mankar, and Y. Bhalerao, Biomaterials in Hip Joint Replacement. Vol. 4. 2016. 113-125. 16. Navarro, M., et al., Biomaterials in orthopaedics. Journal of the Royal Society Interface, 2008. 5(27): p. 1137-1158. 17. Smith-Petersen, M.N., Evolution of mould arthroplasty of the hip joint. J Bone Joint Surg Br, 1948. 30b(1): p. 59-75. 18. Wiles, P., The surgery of the osteoarthritic hip. Br J Surg, 1958. 45(193): p. 488-97. 19. ASTM International, ASTM F138-13a, in Standard Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for Surgical Implants (UNS S31673). 2013: West Conshohocken, PA. 20. Metals Handbook Desk Edition, 2nd Ed, ed. J.R. Davis. 1998: ASM International. 21. Giordano, E., et al., Electrochemical behavior of two austenitic stainless steel biomaterials. Rem-revista Escola De Minas - REM-REV ESC MINAS, 2010. 63. 22. Jaimes, R., et al., New material for orthopedic implants: Electrochemical study of nickel free P558 stainless steel in minimum essential medium. Materials Letters - MATER LETT, 2010. 64: p. 1476-1479. 23. Willert, H.G., et al., Crevice corrosion of cemented titanium alloy stems in total hip replacements. Clin Orthop Relat Res, 1996(333): p. 51-75. 24. Thompson, N.G., R.A. Buchanan, and J.E. Lemons, In vitro corrosion of Ti-6Al-4V and type 316L stainless steel when galvanically coupled with carbon. Journal of Biomedical Materials Research, 1979. 13(1): p. 35-44. 25. Brown, S.R., et al., Long-term survival of McKee-Farrar total hip prostheses. Clin Orthop Relat Res, 2002(402): p. 157-63. 26. R., T.S., S. D., and L.P. D., Corrosion of cemented titanium femoral stems. The Journal of Bone and Joint Surgery. British volume, 2004. 86-B(7): p. 974-978. 27. Gomez, P.F. and J.A. Morcuende, Early Attempts at Hip Arthroplasty: 1700s to 1950s. The Iowa Orthopaedic Journal, 2005. 25: p. 25-29. 28. Charnley, J., The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br, 1972. 54(1): p. 61-76. 29. 3T PRD, Material Specification: Cobalt Chrome Alloy Co28Cr6Mo. 2013 [cited 2017 30 August]; Available from: http://www.3trpd.co.uk. 30. Milošev, I. and H.H. Strehblow, The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution. Electrochimica Acta, 2003. 48(19): p. 2767-2774. 31. Antony, K.C., Wear-Resistant Cobalt-Base Alloys. JOM, 1983. 35(2): p. 52-60. 32. Betteridge, W. Cobalt and its alloys. 1982. 33. Sumner, D.R. and J.O. Galante, Determinants of stress shielding: design versus materials versus interface. Clin Orthop Relat Res, 1992(274): p. 202-12. 34. Cottrell, S.A., An Introduction to Metallurgy. Vol. 2nd edition. 1997, Leeds, United Kingdom: Maney Publishing. 35. International Organization for Standardization, ISO 5832-4:2014, in Implants for surgery — Metallic materials — Part 4: Cobalt-chromium-molybdenum casting alloy. 2014: Berlin, Germany. 36. International Organization for Standardization, ISO 5832-12:2007, in Implants for surgery — Metallic materials — Part 12: Wrought cobalt-chromium-molybdenum alloy. 2007: Switzerland. 37. ASTM International, ASTM F75 - 12, in Standard Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Castings and Casting Alloy for Surgical Implants (UNS R30075). 2012: West Conshohocken, PA. 38. Weisse, B., et al., Failure analysis of in vivo fractured ceramic femoral heads. Engineering Failure Analysis, 2009. 16(4): p. 1188-1194. 39. Bono, J.V., et al., Revision Total Hip Arthroplasty, ed. J.V. Bono, et al. Vol. 1st edition. 1999, New York, US: Springer-Verlag New York. 40. Boutin, P., Arthroplastie totale de la hanche par prothèse en alumine frittée. Étude expérimentale et premières applications cliniques. Revue de Chirurgie Orthopédique et Traumatologique, 2014. 100(1): p. 14-21. 41. Firkins, P.J., et al., A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis. Journal of Biomechanics, 2001. 34(10): p. 1291-1298. 42. Brown, C., et al., Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation. Journal of Materials Science: Materials in Medicine, 2007. 18(5): p. 819-827. 43. Figueiredo-Pina, C.G., et al., Understanding the differences between the wear of metal-on-metal and ceramic-on-metal total hip replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2008. 222(3): p. 285-296. 44. Affatato, S., et al., Mixing and matching in ceramic-on-metal hip arthroplasty: An in-vitro hip simulator study. Journal of Biomechanics, 2009. 42(15): p. 2439-2446. 45. Williams, S., et al., Comparison of ceramic‐on‐metal and metal‐on‐metal hip prostheses under adverse conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2013. 101B(5): p. 770-775. 46. Ingham, E. and J. Fisher, Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000. 214(1): p. 21-37. 47. Masson, B., Emergence of the alumina matrix composite in total hip arthroplasty. International orthopaedics, 2009. 33(2): p. 359-363. 48. BIOLOX delta - Scientific Information and Performance Data. 2015. 49. Dowson, D. and V. Wright, Introduction to the Biomechanics of Joints and Joint Replacements. 1st Edition ed. Vol. Vol. 1. 1981, United Kingdom: Wiley–Blackwell. 50. Kumar, K.E.S. and S. Rakshit, Topology optimization of the hip bone for gait cycle. Structural and Multidisciplinary Optimization, 2020. 62(4): p. 2035-2049. 51. Glenister, R. and S. Sharma, Anatomy, bony pelvis and lower limb, hip. StatPearls [Internet], 2020. 52. Foran, J.R.H. Total Hip Replacement 2015; Available from: http://orthoinfo.aaos.org/topic.cfm?topic=a00377. 53. Singh, A.P. Synovial Fluid Composition and Functions. Available from: http://boneandspine.com/synovial-fluid/. 54. Mavraki, A. and P.M. Cann, Friction and lubricant film thickness measurements on simulated synovial fluids. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2009. 223(3): p. 325-335. 55. Roba, M., Interaction of Synovial Fluid Components with Artificial Hip-Joint Materials 2009, ETH Zurich: Zurich. 56. Yan, Y., et al., Albumin adsorption on CoCrMo alloy surfaces. Scientific reports, 2015. 5: p. 18403-18403. 57. McCarthy, J.C., J.V. Bono, and P.J. O'Donnell, Custom and modular components in primary total hip replacement. Clin Orthop Relat Res, 1997(344): p. 162-71. 58. Toomey, S.D., et al., Modular component exchange for treatment of recurrent dislocation of a total hip replacement in selected patients. J Bone Joint Surg Am, 2001. 83(10): p. 1529-33. 59. McKee, G.K. and J. Watson-Farrar, Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br, 1966. 48(2): p. 245-59. 60. Dowson, D., New joints for the Millennium: Wear control in total replacement hip joints. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001. 215(4): p. 335-358. 61. Walker, P.S. and B.L. Gold, The tribology (friction, lubrication and wear) of all-metal artificial hip joints. Wear, 1971. 17(4): p. 285-299. 62. Jones, D.A., et al., Cobalt toxicity after McKee hip arthroplasty. J Bone Joint Surg Br, 1975. 57(3): p. 289-96. 63. Charnley, J., Arthroplasty of the Hip: A New Operation. The Lancet, 1961. 277(7187): p. 1129-1132. 64. Oral, E. and O.K. Muratoglu, Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications. Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 2007. 265(1): p. 18-22. 65. Galvin, A., et al., Wear of crosslinked polyethylene under different tribological conditions. J Mater Sci Mater Med, 2006. 17(3): p. 235-43. 66. Ingham, E. and J. Fisher, The role of macrophages in osteolysis of total joint replacement. Biomaterials, 2005. 26(11): p. 1271-86. 67. Tipper, J.L., et al., Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator. Wear, 2001. 250(1): p. 120-128. 68. Rieker, C., R. Konrad, and R. Schoun, In vitro comparison of the two hard-hard articulations for total hip replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001. 215(2): p. 153-160. 69. Tipper, J.L., et al., Alumina–alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations. Biomaterials, 2002. 23(16): p. 3441-3448. 70. Kumar, P., et al., Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. J Biomed Mater Res, 1991. 25(7): p. 813-28. 71. Spinelli, M., et al., Ceramic-on-ceramic vs. metal-on-metal in total hip arthroplasty (THA): do 36-mm diameters exhibit comparable wear performance? Keramik-Keramik vs. Metall-Metall in Totalprothesen-Hüftgelenkspfanne-. Arthroplastik: zeigen 36-mm Durchmesser ähnliche Verschleißverhalten? Materialwissenschaft und Werkstofftechnik, 2009. 40(1‐2): p. 94-97. 72. Roualdes, O., et al., In vitro and in vivo evaluation of an alumina-zirconia composite for arthroplasty applications. 2010. 73. Meng, Q., et al., The lubrication performance of the ceramic-on-ceramic hip implant under starved conditions. Journal of the Mechanical Behavior of Biomedical Materials, 2015. 50: p. 70-76. 74. Vassiliou, K., S.C. Scholes, and A. Unsworth, Laboratory studies on the tribology of hard bearing hip prostheses: Ceramic on ceramic and metal on metal. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2007. 221(1): p. 11-20. 75. McMinn, D., et al., Metal on metal surface replacement of the hip. Experience of the McMinn prothesis. Clin Orthop Relat Res, 1996(329 Suppl): p. S89-98. 76. Daniel, J., P.B. Pynsent, and D.J. McMinn, Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br, 2004. 86(2): p. 177-84. 77. Ball, S.T., M.J. Le Duff, and H.C. Amstutz, Early results of conversion of a failed femoral component in hip resurfacing arthroplasty. J Bone Joint Surg Am, 2007. 89(4): p. 735-41. 78. Falez, F., et al., Results of hip resurfacing. Int Orthop, 2011. 35(2): p. 239-43. 79. McMinn, D.J.W., et al., Indications and results of hip resurfacing. International orthopaedics, 2011. 35(2): p. 231-237. 80. Knight, S.R., R. Aujla, and S.P. Biswas, Total Hip Arthroplasty - over 100 years of operative history. Orthopedic reviews, 2011. 3(2): p. e16-e16. 81. Cuckler, J.M., The rationale for metal-on-metal total hip arthroplasty. Clin Orthop Relat Res, 2005. 441: p. 132-6. 82. Archibeck, M.J., et al., The basic science of periprosthetic osteolysis. Instr Course Lect, 2001. 50: p. 185-95. 83. Boutin, P., [Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications]. Rev Chir Orthop Reparatrice Appar Mot, 1972. 58(3): p. 229-46. 84. Osborne, H., Firm pays out to NHS over defective hip replacements, in The Guardian. 2018: https://www.theguardian.com/. 85. Turner, T. Hip Replacement. 2020. 86. Eliaz, N., Corrosion of Metallic Biomaterials: A Review. Materials (Basel, Switzerland), 2019. 12(3): p. 407. 87. Balachandran, S., et al., Atomic Scale Origin of Metal Ion Release from Hip Implant Taper Junctions. Advanced Science. n/a(n/a): p. 1903008. 88. Cooper, H.J., et al., Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. The Journal of bone and joint surgery. American volume, 2012. 94(18): p. 1655-1661. 89. R., W.M., et al., Adverse local tissue reactions in metal-on-polyethylene total hip arthroplasty due to trunnion corrosion. The Bone & Joint Journal, 2015. 97-B(8): p. 1024-1030. 90. Yaszemski, M.J., Biomaterials in orthopedics. 2003: CRC Press. 91. Hill, D., Design engineering of biomaterials for medical devices. Design Engineering of Biomaterials for Medical Devices, by David Hill, pp. 480. ISBN 0-471-96708-4. Wiley-VCH, October 1998., 1998: p. 480. 92. Smith, A.J., et al., Failure rates of metal-on-metal hip resurfacings: analysis of data from the National Joint Registry for England and Wales. The Lancet, 2012. 380(9855): p. 1759-1766. 93. Roposch, A., et al., Functional Outcomes in Children with Osteonecrosis Secondary to Treatment of Developmental Dysplasia of the Hip. JBJS, 2011. 93(24): p. e145. 94. Espallargas, N., C. Torres, and A.I. Muñoz, A metal ion release study of CoCrMo exposed to corrosion and tribocorrosion conditions in simulated body fluids. Wear, 2015. 332(Supplement C): p. 669-678. 95. Muñoz, A.I. and S. Mischler, Interactive effects of albumin and phosphate ions on the corrosion of CoCrMo implant alloy. Journal of the Electrochemical Society, 2007. 154(10): p. C562-C570. 96. Vidal, C.V., et al., Passivation of a CoCrMo PVD alloy with biomedical composition under simulated physiological conditions studied by EQCM and XPS. Journal of The Electrochemical Society, 2012. 159(5): p. C233-C243. 97. Li, Y.-S., et al., Surface-enhanced Raman spectroelectrochemical studies of corrosion films on implant Co–Cr–Mo alloy in biosimulating solutions. Journal of Raman Spectroscopy, 1999. 30(2): p. 97-103. 98. Hedberg, Y. and I. Odnevall Wallinder, Metal release and speciation of released chromium from a biomedical CoCrMo alloy into simulated physiologically relevant solutions. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2014. 102(4): p. 693-699. 99. Yan, Y., D. Dowson, and A. Neville, In-situ electrochemical study of interaction of tribology and corrosion in artificial hip prosthesis simulators. Journal of the Mechanical Behavior of Biomedical Materials, 2013. 18: p. 191-199. 100. Hesketh, J., et al., Biotribocorrosion: Some electrochemical observations from an instrumented hip joint simulator. Tribology International, 2013. 59: p. 332-338. 101. Bazzoni, A., S. Mischler, and N. Espallargas, Tribocorrosion of pulsed plasma-nitrided CoCrMo implant alloy. Tribology Letters, 2013. 49(1): p. 157-167. 102. Alemón, B., et al., Tribocorrosion behavior and ions release of CoCrMo alloy coated with a TiAlVCN/CNx multilayer in simulated body fluid plus bovine serum albumin. Tribology International, 2015. 81: p. 159-168. 103. Hodgson, A.W.E., et al., Passive and transpassive behaviour of CoCrMo in simulated biological solutions. Electrochimica Acta, 2004. 49(13): p. 2167-2178. 104. Milošev, I., T. Kosec, and H.H. Strehblow, XPS and EIS study of the passive film formed on orthopaedic Ti–6Al–7Nb alloy in Hank's physiological solution. Electrochimica Acta, 2008. 53(9): p. 3547-3558. 105. Metikos-Huković, M., et al., Influence of alloying elements on the corrosion stability of CoCrMo implant alloy in Hank's solution. Acta Biomater, 2006. 2(6): p. 693-700. 106. Lhotka, C., et al., Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J Orthop Res, 2003. 21(2): p. 189-95. 107. Martin, E.J., et al., Dominant role of molybdenum in the electrochemical deposition of biological macromolecules on metallic surfaces. Langmuir, 2013. 29(15): p. 4813-4822. 108. Milošev, I., The effect of biomolecules on the behaviour of CoCrMo alloy in various simulated physiological solutions. Electrochimica Acta, 2012. 78: p. 259-273. 109. Bauer, T.W., Particles and periimplant bone resorption. Clin Orthop Relat Res, 2002(405): p. 138-43. 110. Vieira, A.C., et al., Mechanical and electrochemical deterioration mechanisms in the tribocorrosion of Al alloys in NaCl and in NaNO3 solutions. Corrosion Science, 2012. 54: p. 26-35. 111. Espallargas, N., et al., A new experimental technique for quantifying the galvanic coupling effects on stainless steel during tribocorrosion under equilibrium conditions. Wear, 2013. 307(1): p. 190-197. 112. Matusiewicz, H., Potential release of in vivo trace metals from metallic medical implants in the human body: From ions to nanoparticles – A systematic analytical review. Acta Biomaterialia, 2014. 10(6): p. 2379-2403. 113. Agency, M.a.H.p.R., Metal-on-Metal (MoM) Hip Replacements - Guidance on Implantation and Patient Management Medical Safety Alert. 2015: GOV.UK. 114. Matharu, G.S., et al., Adverse reactions to metal debris occur with all types of hip replacement not just metal-on-metal hips: a retrospective observational study of 3340 revisions for adverse reactions to metal debris from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. BMC Musculoskelet Disord, 2016. 17(1): p. 495. 115. Doorn, P.F., et al., Tissue reaction to metal on metal total hip prostheses. Clin Orthop Relat Res, 1996(329 Suppl): p. S187-205. 116. Germain, M.A., et al., Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials, 2003. 24(3): p. 469-79. 117. Catelas, I., et al., Cytotoxic and apoptotic effects of cobalt and chromium ions on J774 macrophages - Implication of caspase-3 in the apoptotic pathway. J Mater Sci Mater Med, 2001. 12(10-12): p. 949-53. 118. Granchi, D., et al., Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res B Appl Biomater, 2006. 77(2): p. 257-64. 119. Hallab, N.J., K. Mikecz, and J.J. Jacobs, A triple assay technique for the evaluation of metal-induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty. J Biomed Mater Res, 2000. 53(5): p. 480-9. 120. Masse, A., et al., Ion release and chromosomal damage from total hip prostheses with metal-on-metal articulation. J Biomed Mater Res B Appl Biomater, 2003. 67(2): p. 750-7. 121. Willert, H.G., et al., Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am, 2005. 87(1): p. 28-36. 122. Kurtz, S.M., et al., Prevalence of Metal-on-Metal Bearings in the United States, S. Kurtz, et al., Editors. 2013, ASTM International: West Conshohocken, PA. p. 3-18. 123. Clayton, R.A., et al., Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip. A case report. J Bone Joint Surg Am, 2008. 90(9): p. 1988-93. 124. Park, Y.S., et al., Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg Am, 2005. 87(7): p. 1515-21. 125. Dobbs, H.S. and M.J. Minski, Metal ion release after total hip replacement. Biomaterials, 1980. 1(4): p. 193-198. 126. Michel, R., et al., Systemic effects of implanted prostheses made of cobalt-chromium alloys. Archives of Orthopaedic and Trauma Surgery, 1991. 110(2): p. 61-74. 127. Murgatroyd, S., Pseudotumor Presenting as a Pelvic Mass: A Complication of Eccentric Wear of a Metal on Polyethylene Hip Arthroplasty. The Journal of arthroplasty, 2011. 27: p. 820.e1-4. 128. Walsh, A.J., V.S. Nikolaou, and J. Antoniou, Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty. J Arthroplasty, 2012. 27(2): p. 324.e5-8. 129. Lyvers, M., et al., Electrochemically induced tribolayer with molybdenum for hip implants: Tribocorrosion and biocompatibility study. Thin Solid Films, 2017. 644: p. 82-91. 130. Fontana, M.G. and N.D. Greene, Corrosion Engineering. 2nd ed. ed. 1993, Japan: McGraw-Hill. 131. Talbot, D. and J. Talbot, Corrosion science and technology. 2nd ed. 2007, Boca Raton, Fla;London;: CRC Press. 132. Ratner, B.D., et al., Biomaterials science: an introduction to materials in medicine. 2004: Academic press. 133. Kamachimudali, U., T.M. Sridhar, and B. Raj, Corrosion of bio implants. Sadhana, 2003. 28(3): p. 601-637. 134. Tait, W.S., An Introduction to Electrochemical Corrosion Testing for Practicing Engineers & Scientists. 1994: Pair O Docs Pubns. 135. Bryant, M. and A. Neville, Corrosion and mechanical properties. Orthopaedics and Trauma, 2016. 30(3): p. 176-191. 136. Scully, J.R. and K. Lutton, Polarization Behavior of Active Passive Metals and Alloys, in Encyclopedia of Interfacial Chemistry, K. Wandelt, Editor. 2018, Elsevier: Oxford. p. 439-447. 137. Frankel, G.S., Pitting Corrosion of Metals: A Review of the Critical Factors. Journal of The Electrochemical Society, 1998. 145(6): p. 2186-2198. 138. Brox, B. and I. Olefjord, Preferential dissolution of iron during polarization of stainless steels in acids. Stainless Steel'84, Chalmers University of Technology, 1984: p. 134-142. 139. Milosev, I. and M. Remskar, In vivo production of nanosized metal wear debris formed by tribochemical reaction as confirmed by high-resolution TEM and XPS analyses. J Biomed Mater Res A, 2009. 91(4): p. 1100-10. 140. Kocijan, A., I. Milosev, and B. Pihlar, Cobalt-based alloys for orthopedic applications studied by electrochemical and XPS analysis. Vol. 15. 2004. 643-50. 141. Bryant, M., Fretting-crevice corrosion of cemented metal on metal total hip replacements. 2013, University of Leeds. 142. Hoar, T., The production and breakdown of the passivity of metals. Corrosion Science, 1967. 7: p. 341-355. 143. Uhlig, H.H., Adsorbed and Reaction‐Product Films on Metals. Journal of the Electrochemical Society, 1950. 97(11): p. 215C. 144. Richardson, J.A. and G.C. Wood, The Interpretation of Impedance Changes on Oxide-Coated Aluminum Produced by Immersion in Inhibitive and Corrosive Aqueous Media. Journal of The Electrochemical Society, 1973. 120(2): p. 193. 145. Pistorius, P.C. and G.T. Burstein, Metastable pitting corrosion of stainless steel and the transition to stability. Philosophical Transactions of the Royal Society of London. Series A: Physical and Engineering Sciences, 1992. 341(1662): p. 531-559. 146. ASTM International, Standard Guide for Examination and Evaluation of Pitting Corrosion, in ASTM G46-94(2013). 2013, PA: West Conshohocken. 147. Roy, A., D. Fleming, and S. Gordon. Effect of chloride concentration and pH on pitting corrosion of waste package container materials. 1996. 148. NACE. Crevice Corrosion. [cited 2017 16 August]; Available from: https://www.nace.org/Corrosion-Central/Corrosion-101/Crevice-Corrosion/. 149. Oldfield, J.W. and W.H. Sutton, New Technique for Predicting the Performance of Stainless Steels in Sea Water and other Chloride-containing Environments. British Corrosion Journal, 1980. 15(1): p. 31-34. 150. Oldfield, J.W. and W.H. Sutton, Crevice Corrosion of Stainless Steels: II. Experimental studies. British Corrosion Journal, 1978. 13(3): p. 104-111. 151. Foundation, A.E., Hip & Knee Book, in TRUNNIONOSIS. 2017: hipandkneebook.com. 152. Gilbert, J.L., C.A. Buckley, and J.J. Jacobs, In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. Journal of Biomedical Materials Research, 1993. 27(12): p. 1533-1544. 153. Gilbert, J.L., et al., Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. J Bone Joint Surg Am, 1994. 76(1): p. 110-5. 154. NACE. Galvanic Corrosion. Available from: https://www.nace.org/Corrosion-Central/Corrosion-101/Galvanic-Corrosion/. 155. Collier, J.P., et al., Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems. Clinical orthopaedics and related research, 1991(271): p. 305-312. 156. Lucas, L.C., R.A. Buchanan, and J.E. Lemons, Investigations on the galvanic corrosion of multialloy total hip prostheses. Journal of Biomedical Materials Research, 1981. 15(5): p. 731-747. 157. Serhan, H., et al., Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern? Spine J, 2004. 4(4): p. 379-87. 158. Virtanen, S., et al., Special modes of corrosion under physiological and simulated physiological conditions. Acta Biomater, 2008. 4(3): p. 468-76. 159. Mears, D.C., The use of dissimilar metals in surgery. Journal of Biomedical Materials Research, 1975. 9(4): p. 133-148. 160. Reclaru, L., et al., Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material. Biomaterials, 2002. 23(16): p. 3479-85. 161. Tan, Y., Homogeneous Electrode Models and Uniform Corrosion Measurements, in Heterogeneous Electrode Processes and Localized Corrosion, R.W. Revie, Editor. 2012, John Wiley & Sons, Inc.: New Jersey, US. p. 1-35. 162. Poursaee, A., 9 - Corrosion measurement and evaluation techniques of steel in concrete structures, in Corrosion of Steel in Concrete Structures, A. Poursaee, Editor. 2016, Woodhead Publishing: Oxford. p. 169-191. 163. Vidal, C.V., Study of the degradation mechanisms of the CoCrMo biomedical alloy in physiological media by electrochemical techniques and surface analysis. 2012, Universitat Politècnica de València. 164. Scully, J., D. Silverman, and M. Kendig, Electrochemical Impedance: Analysis and Interpretation. 1993. 165. Milošev, I., T. Kosec, and H.-H.J.E.A. Strehblow, XPS and EIS study of the passive film formed on orthopaedic Ti–6Al–7Nb alloy in Hank's physiological solution. 2008. 53(9): p. 3547-3558. 166. Moreto, J.A., et al., Effect of Temperature, Electrolyte Composition and Immersion Time on the Electrochemical Corrosion Behavior of CoCrMo Implant Alloy Exposed to Physiological Serum and Hank's Solution %J Materials Research. 2018. 21. 167. Namus, R., et al., The influence of protein concentration, temperature and cathodic polarization on the surface status of CoCrMo biomedical grade alloys. Applied Surface Science, 2020. 499: p. 143908. 168. Dambatta, M.s., et al., In vitro degradation and cell viability assessment of Zn-3Mg alloy for biodegradable bone implants. Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine, 2015. 229: p. 335-342. 169. Growcock, F.B. and R.J. Jasinski, Time‐Resolved Impedance Spectroscopy of Mild Steel in Concentrated Hydrochloric Acid. Journal of The Electrochemical Society, 1989. 136(8): p. 2310-2314. 170. Olsson, C.O.A. and D. Landolt, Anodisation of a Nb–Zr alloy. Electrochimica Acta, 2003. 48(27): p. 3999-4011. 171. Helsen, J.A. and H. Jürgen Breme, Metals as biomaterials. 1998. 172. Bommersbach, P., et al., Formation and behaviour study of an environment-friendly corrosion inhibitor by electrochemical methods. Electrochimica Acta, 2005. 51(6): p. 1076-1084. 173. STLE. [cited 2017 01 August]; Available from: http://www.stle.org/files/What_is_tribology/Tribology_Applications.aspx. 174. Gohar, R. and H. Rahnejat, Fundamentals of tribology. 2nd ed. 2012, London: Imperial College Press. 175. Stachowiak, G.W. and A.W. Batchelor, Engineering tribology. Fourth;4;4th; ed. 2014, Oxford: Butterworth-Heinemann. 176. Singer, I., Surface Analysis, in Handbook of Lubrication and Tribology, Volume II. 2012, CRC Press. p. 1-20. 177. Greenwood, J.A. and J.B.P. Williamson, Contact of nominally flat surfaces. Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences, 1966. 295(1442): p. 300. 178. Shigley, J.E., Mechanical Engineering Design. 5th Edition, Chapter 2 ed. 1989: McGraw-Hill, Inc. 179. Williams, J.A., Engineering tribology. 1994, Oxford: Oxford University Press. 180. Hertz, H., On the Contact of Elastic Solids. J Reine Angew Math, 1881. 92: p. 156-171. 181. Archard, J.F. and T.E. Allibone, Elastic deformation and the laws of friction. Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences, 1957. 243(1233): p. 190-205. 182. Williams, J., Engineering tribology. 2005: Cambridge University Press. 183. Moore, J., et al. Mechanics Map - Open Textbook Project. Engineering Mechanic [cited 2020 2 October]; Available from: http://mechanicsmap.psu.edu/websites/6_friction/dry_friction/dryfriction.html. 184. Association, A.B., The Principles and Design of Foundation Brake Rigging. 1921: Air brake association. 185. Hanaor, D.A.H., Y. Gan, and I. Einav, Static friction at fractal interfaces. Tribology International, 2016. 93: p. 229-238. 186. Yan, Y., Corrosion and Tribo-Corrosion Behaviour of Metallic Orthopaedic Implant Materials. 2006, University of Leeds. 187. Flugsrud, G.B., et al., The effect of middle-age body weight and physical activity on the risk of early revision hip arthroplasty: A cohort study of 1,535 individuals. Acta Orthopaedica, 2007. 78(1): p. 99-107. 188. Damm, P., et al., Friction in Total Hip Joint Prosthesis Measured In Vivo during Walking. PloS one, 2013. 8: p. e78373. 189. Affatato, S., 7 - Tribological interactions of modern biomaterials used in total hip arthroplasty (THA), in Perspectives in Total Hip Arthroplasty, S. Affatato, Editor. 2014, Woodhead Publishing. p. 99-116. 190. Totten, G.E. and H. Liang, Mechanical Tribology. 2004, New York: Marcel Dekker, Inc. 191. Stachowiak, G.W., Wear-materials, mechanisms and practice. 2005, Chichester: Wiley. 192. Stachowiak, G.W. and A.W. Batchelor, Engineering tribology. 3rd;3; ed. 2005, Amsterdam;Boston;: Elsevier Butterworth-Heinemann. 193. Stachowiak, G.W. and A.W. Batchelor, 13 - Corrosive and Oxidative Wear, in Engineering Tribology (Third Edition). 2006, Butterworth-Heinemann: Burlington. p. 573-593. 194. Vingsbo, O. and S. Söderberg, On fretting maps. Wear, 1988. 126(2): p. 131-147. 195. Bryant, M., et al., Galvanically enhanced fretting-crevice corrosion of cemented femoral stems. Journal of the Mechanical Behavior of Biomedical Materials, 2014. 40: p. 275-286. 196. Oladokun, A., Mechanism of Fretting Corrosion at the Modular Taper Interface of Hip Prosthesis. 2017, University of Leeds. 197. Kondo, Y., T. Koyama, and S. Sasaki, Tribological Properties of Ionic Liquids, in Ionic Liquids - New Aspects for the Future, J.-i. Kadokawa, Editor. 2013, InTech: Rijeka. p. Ch. 05. 198. Neville, A.a.M., A., Wear and Chemistry of Lubricants, in Wear: Materials, Mechanisms and Practice, G.W. Stachowiak, Editor. 2005, John Wiley & Sons: Hoboken. p. 71–94. 199. Beadling, A.R., Biotribocorrosion of Hard-on-Hard Bearing Surfaces in Orthopaedic Hip Replacements. 2016, University of Leeds. 200. Jin, Z., et al., Analysis and modelling of wear of cobalt-chrome alloys in a pin-on-plate test for a metal-on-metal total hip replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000. 214(6): p. 559-568. 201. Sonntag, R., et al., Hard-on-hard lubrication in the artificial hip under dynamic loading conditions. PloS one, 2013. 8(8): p. e71622-e71622. 202. Jalali-Vahid, D., et al., Prediction of lubricating film thickness in UHMWPE hip joint replacements. J Biomech, 2001. 34(2): p. 261-6. 203. Khaemba, D.N., Raman spectroscopic studies of friction modifier Molybdenum DialkyldiThioCarbamate (MoDTC). 2016, University of Leeds. 204. Mischler, S., Triboelectrochemical techniques and interpretation methods in tribocorrosion: A comparative evaluation. Tribology International, 2008. 41(7): p. 573-583. 205. López-Ortega, A., J.L. Arana, and R. Bayón, Tribocorrosion of Passive Materials: A Review on Test Procedures and Standards. International Journal of Corrosion, 2018. 2018: p. 7345346. 206. Mathew, M.T., et al., Significance of Tribocorrosion in Biomedical Applications: Overview and Current Status. Advances in Tribology, 2009. 2009: p. 250986. 207. Landolt, D. and S. Mischler, Tribocorrosion of passive metals and coatings. 2011: Elsevier. 208. Watson, S.W., et al., Methods of measuring wear-corrosion synergism. Wear, 1995. 181-183: p. 476-484. 209. Landolt, D., Electrochemical and materials aspects of tribocorrosion systems. Journal of Physics D: Applied Physics, 2006. 39(15): p. 3121-3127. 210. Diomidis, N., et al., Tribocorrosion of stainless steel in sulfuric acid: Identification of corrosion-wear components and effect of contact area. Vol. 269. 2010. 93-103. 211. Mischler, S. and P. Ponthiaux, A round robin on combined electrochemical and friction tests on alumina/stainless steel contacts in sulphuric acid. Wear, 2001. 248(1): p. 211-225. 212. Fuentes, E., et al., Advanced Surface Treatments on Titanium and Titanium Alloys Focused on Electrochemical and Physical Technologies for Biomedical Applications, in Biomaterial-supported Tissue Reconstruction or Regeneration. 2019. 213. Vieira, A., et al., Mechanical and electrochemical deterioration mechanisms in the tribocorrosion of Al alloys in NaCl and in NaNO 3 solutions. Corrosion Science, 2012. 54: p. 26-35. 214. Igual Muñoz, A. and N. Espallargas, 5 - Tribocorrosion mechanisms in sliding contacts, in Tribocorrosion of Passive Metals and Coatings, D. Landolt and S. Mischler, Editors. 2011, Woodhead Publishing. p. 118-152. 215. ASTM International, ASTM G119-06, in Standard Guide for Determining Synergism Between Wear and Corrosion. 2016, ASTM International: West Conshohocken, PA. 216. Yan, Y., 7 - Growth of passive tribofilms in medical implants, in Bio-Tribocorrosion in Biomaterials and Medical Implants. 2013, Woodhead Publishing. p. 147-168. 217. Zhang, Y., X.-Y. Yin, and F.-Y. Yan, Tribocorrosion behaviour of type S31254 steel in seawater: Identification of corrosion–wear components and effect of potential. Materials Chemistry and Physics, 2016. 179: p. 273-281. 218. Ma, F., et al., Structural, mechanical and tribocorrosion behaviour in artificial seawater of CrN/AlN nano-multilayer coatings on F690 steel substrates. Applied Surface Science, 2018. 428: p. 404-414. 219. Priya, R., C. Mallika, and U.K. Mudali, Wear and tribocorrosion behaviour of 304L SS, Zr-702, Zircaloy-4 and Ti-grade2. Wear, 2014. 310(1): p. 90-100. 220. Stack, M.M. and G.H. Abdulrahman, Mapping erosion-corrosion of carbon steel in oil exploration conditions: Some new approaches to characterizing mechanisms and synergies. Tribology International, 2010. 43(7): p. 1268-1277. 221. Mathew, M.T., et al., Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: A comparison between two testing systems. Wear, 2011. 271(9): p. 1210-1219. 222. UNE 112086:2016, in Tribocorrosion testing procedure for passivating materials. 2016, Asociación Española de Normalización (UNE). 223. Bryant, M. and A. Neville, Fretting corrosion of CoCr alloy: Effect of load and displacement on the degradation mechanisms. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2017. 231(2): p. 114-126. 224. Mischler, S., et al., Influence of passivity on the tribocorrosion of carbon steel in aqueous solutions. Wear, 2001. 251(1): p. 1295-1307. 225. Godet, M., The third-body approach: A mechanical view of wear. Wear, 1984. 100(1): p. 437-452. 226. Vinothkumar, K.R. and R. Henderson, Structures of membrane proteins. Quarterly reviews of biophysics, 2010. 43(1): p. 65-158. 227. Protein Concept Map. 2003: Pearson Education, Inc., publishing as Benjamin Cummings. 228. Protein-Surface Interactions, in An Introduction To Tissue‐Biomaterial Interactions. 2002. p. 37-52. 229. Maskiewicz, V.K., et al., Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses. J Biomed Mater Res B Appl Biomater, 2010. 94(2): p. 429-40. 230. Parkes, M., et al., The effect of buffer solution choice on protein adsorption and lubrication. Tribology International, 2014. 72: p. 108-117. 231. Malvern Panalytical. Using Raman Spectroscopy to Understand the Conformational Stability of Protein Therapeutics. AZoM, viewed 15 January 2020. viewed 15 January 2020; Available from: https://www.azom.com/article.aspx?ArticleID=11142. 232. Foley, S., et al., Photolysis of Bovine Serum Albumin by near UV irradiation. 2011. 233. Lewis, E.N., et al., Combined dynamic light scattering and Raman spectroscopy approach for characterizing the aggregation of therapeutic proteins. Molecules (Basel, Switzerland), 2014. 19(12): p. 20888-20905. 234. Thawornchinsombut, S., et al., Raman Spectroscopy Determines Structural Changes Associated with Gelation Properties of Fish Proteins Recovered at Alkaline pH. Journal of Agricultural and Food Chemistry, 2006. 54(6): p. 2178-2187. 235. Zhang, S., et al., Raman Spectroscopic Characterization of Structural Changes in Heated Whey Protein Isolate upon Soluble Complex Formation with Pectin at Near Neutral pH. Journal of Agricultural and Food Chemistry, 2012. 60(48): p. 12029-12035. 236. Wang, C.-H., et al., The effect of disulfide bonds on protein folding, unfolding, and misfolding investigated by FT–Raman spectroscopy. Journal of Raman Spectroscopy, 2016. 47(8): p. 940-947. 237. Chen, M.C. and R.C. Lord, Laser-excited Raman spectroscopy of biomolecules. VIII. Conformational study of bovine serum albumin. J Am Chem Soc, 1976. 98(4): p. 990-2. 238. Wesełucha-Birczyńska, A., et al., Raman micro-spectroscopy tracing human lymphocyte activation. The Analyst, 2013. 138. 239. Esmonde-White, K.A., et al., Raman spectroscopy of synovial fluid as a tool for diagnosing osteoarthritis. J Biomed Opt, 2009. 14(3): p. 034013. 240. Lin, V.J.C. and J.L. Koenig, Raman studies of bovine serum albumin. Biopolymers, 1976. 15(1): p. 203-218. 241. Liang, M., et al., A simple and direct isolation of whey components from raw milk by gel filtration chromatography and structural characterization by Fourier transform Raman spectroscopy. Talanta, 2006. 69(5): p. 1269-1277. 242. Qian, W. and S. Krimm, Vibrational studies of the disulfide group in proteins. VII. Normal mode analysis of the Raman spectra of erabutoxin, γ‐II crystallin and immunoglobulin. Journal of Raman spectroscopy, 1992. 23(10): p. 517-521. 243. Hedberg, Y., et al., Surface-protein interactions on different stainless steel grades: effects of protein adsorption, surface changes and metal release. Journal of Materials Science: Materials in Medicine, 2013. 24(4): p. 1015-1033. 244. Oates, K.M.N., et al., Rheopexy of synovial fluid and protein aggregation. Journal of the Royal Society, Interface, 2006. 3(6): p. 167-174. 245. Merritt, K., S.A. Brown, and N.A. Sharkey, The binding of metal salts and corrosion products to cells and proteins in vitro. Journal of Biomedical Materials Research, 1984. 18(9): p. 1005-1015. 246. Horbett, T.A., The role of adsorbed proteins in tissue response to biomaterials, in Biomaterials Science. 2004, Elsevier Academic Press: London. 247. Hlady, V. and J. Buijs, Protein adsorption on solid surfaces. Current Opinion in Biotechnology, 1996. 7(1): p. 72-77. 248. Gray, J.J., The interaction of proteins with solid surfaces. Current Opinion in Structural Biology, 2004. 14(1): p. 110-115. 249. Kopac, T., K. Bozgeyik, and J. Yener, Effect of pH and temperature on the adsorption of bovine serum albumin onto titanium dioxide. Colloids and Surfaces A: Physicochemical and Engineering Aspects, 2008. 322(1): p. 19-28. 250. Wang, Z., Y. Yan, and L. Qiao, Protein adsorption on implant metals with various deformed surfaces. Colloids and Surfaces B: Biointerfaces, 2017. 156: p. 62-70. 251. Valero Vidal, C., A. Olmo Juan, and A. Igual Muñoz, Adsorption of bovine serum albumin on CoCrMo surface: Effect of temperature and protein concentration. Colloids and Surfaces B: Biointerfaces, 2010. 80(1): p. 1-11. 252. Zhu, J., N. Xu, and C. Zhang, Characteristics of copper corrosion in simulated uterine fluid in the presence of protein. Advances in contraception, 1999. 15(3): p. 179-190. 253. Li, J., et al., Comparison of the release behaviors of cupric ions from metallic copper and a novel composite in simulated body fluid. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2008. 85B(1): p. 172-179. 254. Ithurbide, A., et al., XPS and flow-cell EQCM study of albumin adsorption on passivated chromium surfaces: Influence of potential and pH. Electrochimica Acta, 2007. 53(3): p. 1336-1345. 255. Valero-Vidal, C., et al., Adsorption of BSA on Passivated CoCrMo PVD Alloy: An EQCM and XPS Investigation. Journal of The Electrochemical Society, 2014. 161(6): p. C294-C301. 256. Wagner, M.S., T.A. Horbett, and D.G. Castner, Characterizing multicomponent adsorbed protein films using electron spectroscopy for chemical analysis, time-of-flight secondary ion mass spectrometry, and radiolabeling: capabilities and limitations. Biomaterials, 2003. 24(11): p. 1897-1908. 257. Muñoz, A.I. and S. Mischler, Electrochemical Quartz Crystal Microbalance and X-Ray Photoelectron Spectroscopy study of cathodic reactions in Bovine Serum Albumin containing solutions on a Physical Vapour Deposition-CoCrMo biomedical alloy. Electrochimica Acta, 2015. 180(Supplement C): p. 96-103. 258. Munoz, A.I. and S. Mischler, Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys. J Mater Sci Mater Med, 2011. 22(3): p. 437-50. 259. Yan, Y., A. Neville, and D. Dowson, Biotribocorrosion of CoCrMo orthopaedic implant materials - Assessing the formation and effectof the biofilm. Tribology International, 2007. 40(10-12): p. 1492-1499. 260. Williams, D.F., I.N. Askill, and R. Smith, Protein absorption and desorption phenomena on clean metal surfaces. J Biomed Mater Res, 1985. 19(3): p. 313-20. 261. Contu, F., B. Elsener, and H. Bohni, Characterization of implant materials in fetal bovine serum and sodium sulfate by electrochemical impedance spectroscopy. II. Coarsely sandblasted samples. J Biomed Mater Res A, 2003. 67(1): p. 246-54. 262. Kerwell, S., et al., Electrochemically Induced Film Formation on CoCrMo Alloy for Hip Implant Application. Vol. 3. 2017. 263. Hedberg, Y., Role of proteins in the degradation of relatively inert alloys inthe human body. 2018. 2. 264. Yang, J. and J. Black, Competitive binding of chromium, cobalt and nickel to serum proteins. Biomaterials, 1994. 15(4): p. 262-268. 265. Hallab, N.J., et al., Systemic metal–protein binding associated with total joint replacement arthroplasty. Journal of Biomedical Materials Research, 2000. 49(3): p. 353-361. 266. Jacobs, J.J., et al., Metal degradation products: a cause for concern in metal-metal bearings? Clin Orthop Relat Res, 2003(417): p. 139-47. 267. Hedberg, Y.S., Role of proteins in the degradation of relatively inert alloys in the human body. npj Materials Degradation, 2018. 2(1): p. 26. 268. Thompson, C., et al., Impact of Magnetic Stirring on Stainless Steel Integrity: Effect on Biopharmaceutical Processing. J Pharm Sci, 2017. 106(11): p. 3280-3286. 269. Rosenberg, A.S., Effects of protein aggregates: an immunologic perspective. Aaps j, 2006. 8(3): p. E501-7. 270. Hedberg, Y.S., et al., Can Cobalt(II) and Chromium(III) Ions Released from Joint Prostheses Influence the Friction Coefficient? ACS Biomaterials Science & Engineering, 2015. 1(8): p. 617-620. 271. Arenas, M., et al., Electrochemical noise measurements of AISI 316L during wear in simulated physiological media. Corrosion Engineering, Science and Technology, 2014. 49: p. 656-660. 272. Liang, M., et al., A simple and direct isolation of whey components from raw milk by gel filtration chromatography and structural characterization by Fourier transform Raman spectroscopy. Talanta, 2006. 69(5): p. 1269-1277. 273. Mishina, H. and M. Kojima, Changes in human serum albumin on arthroplasty frictional surfaces. Wear, 2008. 265(5): p. 655-663. 274. Wimmer, M.A., et al., The acting wear mechanisms on metal-on-metal hip joint bearings: in vitro results. Wear, 2001. 250(1): p. 129-139. 275. Bergmann, G., et al., High-Tech Hip Implant for Wireless Temperature Measurements In Vivo. PLOS ONE, 2012. 7(8): p. e43489. 276. Myant, C., et al., Lubrication of metal-on-metal hip joints: The effect of protein content and load on film formation and wear. Journal of the Mechanical Behavior of Biomedical Materials, 2012. 6: p. 30-40. 277. Ma, L. and W.M. Rainforth, A study of Biolox® delta subject to water lubricated reciprocating wear. Tribology International, 2010. 43(10): p. 1872-1881. 278. Li, X., et al., Depassivation–repassivation behavior of a CoCrMo alloy under Tribological contact in Simulated body Fluids. Int J Electrochem Sci, 2017. 12: p. 2495-2505. 279. Sun, D., J. Wharton, and R. Wood, The Effects of Protein and pH on the Tribo-Corrosion Performance of Cast CoCrMo — A Combined Electrochemical and Tribological Study. 2010. p. 825-826. 280. Hesketh, J.E.T., Tribocorrosion of Total Hip Replacements. 2012, University of Leeds. 281. Runa, M.J., M.T. Mathew, and L.A. Rocha, Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems. Tribology International, 2013. 68: p. 85-93. 282. Wang, Z., et al., Effect of electrochemical corrosion on the subsurface microstructure evolution of a CoCrMo alloy in albumin containing environment. Applied Surface Science, 2017. 406: p. 319-329. 283. De Motte, R., et al., Near surface pH measurements in aqueous CO2 corrosion. Electrochimica Acta, 2018. 290: p. 605-615. 284. Merritt, K. and S.A. Brown, Effect of proteins and pH on fretting corrosion and metal ion release. J Biomed Mater Res, 1988. 22(2): p. 111-20. 285. Valero Vidal, C. and A. Igual Muñoz, Effect of physico-chemical properties of simulated body fluids on the electrochemical behaviour of CoCrMo alloy. Electrochimica Acta, 2011. 56(24): p. 8239-8248. 286. Sadiq, K., M.M. Stack, and R.A. Black, Wear mapping of CoCrMo alloy in simulated bio-tribocorrosion conditions of a hip prosthesis bearing in calf serum solution. Mater Sci Eng C Mater Biol Appl, 2015. 49: p. 452-462. 287. Heinicke, G., Tribochemistry. 1984: John Wiley & Sons. 288. Hsu, S.M., J. Zhang, and Z. Yin, The Nature and Origin of Tribochemistry. Tribology Letters, 2002. 13(2): p. 131-139. 289. Fischer, T.E., Tribochemistry. Annual Review of Materials Science, 1988. 18(1): p. 303-323. 290. Adams, H.L., et al., Shear-Induced Mechanochemistry: Pushing Molecules Around. The Journal of Physical Chemistry C, 2015. 119(13): p. 7115-7123. 291. Jelita Rydel, J., R.H. Vegter, and P.E.J. Rivera-Díaz-del-Castillo, Tribochemistry of bearing steels: A new AFM method to study the material–tribofilm correlation. Tribology International, 2016. 98: p. 74-81. 292. Wan, S., et al., Tribochemistry of adaptive integrated interfaces at boundary lubricated contacts. Scientific Reports, 2017. 7(1): p. 9935. 293. Meng, Q.E., et al., Contact mechanics and lubrication analyses of ceramic-on-metal total hip replacements. Tribology International, 2013. 63: p. 51-60. 294. McEntire, B., et al., Silicon Nitride Bearings for Total Joint Arthroplasty. Lubricants, 2016. 4(4): p. 35. 295. Nečas, D., et al., The effect of lubricant constituents on lubrication mechanisms in hip joint replacements. Journal of the Mechanical Behavior of Biomedical Materials, 2016. 55: p. 295-307. 296. Vrbka, M., et al., Study of film formation in bovine serum lubricated contacts under rolling/sliding conditions. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2013. 227(5): p. 459-475. 297. Ghosh, S., et al., Tribological performance of the biological components of synovial fluid in artificial joint implants. Science and technology of advanced materials, 2015. 16(4): p. 045002-045002. 298. Wimmer, M.A., et al., Tribochemical reaction on metal-on-metal hip joint bearings - A comparison between in-vitro and in-vivo results. WEAR, 2003. 255(2): p. 1007-1014. 299. Pourzal, R., et al., Micro-structural alterations within different areas of articulating surfaces of a metal-on-metal hip resurfacing system. Wear, 2009. 267(5): p. 689-694. 300. Pourzal, R., et al., Characterization of wear particles generated from CoCrMo alloy under sliding wear conditions. Wear, 2011. 271(9): p. 1658-1666. 301. Zeng, P., et al., Subsurface characterisation of wear on mechanically polished and electro-polished biomedical grade CoCrMo. Wear, 2015. 332-333: p. 650-661. 302. Mathew, M.T., J.J. Jacobs, and M.A. Wimmer, Wear-Corrosion Synergism in a CoCrMo Hip Bearing Alloy Is Influenced by Proteins. Clinical Orthopaedics and Related Research, 2012. 470(11): p. 3109-3117. 303. Sargeant, A. and T. Goswami, Hip implants: Paper V. Physiological effects. Materials & Design, 2006. 27(4): p. 287-307. 304. Jacobs, J.J., J.L. Gilbert, and R.M. Urban, Corrosion of metal orthopaedic implants. J Bone Joint Surg Am, 1998. 80(2): p. 268-82. 305. Rabe, M., D. Verdes, and S. Seeger, Understanding protein adsorption phenomena at solid surfaces. Advances in Colloid and Interface Science, 2011. 162(1): p. 87-106. 306. Anissian, H.L., et al., The wear pattern in metal-on-metal hip prostheses. J Biomed Mater Res, 2001. 58(6): p. 673-8. 307. Smith, S.L., D. Dowson, and A.A.J. Goldsmith, The lubrication of metal-on-metal total hip joints: A slide down the Stribeck curve. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2001. 215(5): p. 483-493. 308. Beadling, A.R., et al., Tribocorrosion of hard-on-hard total hip replacements with metal and ceramic counterfaces under standard and adverse loading conditions. Tribology International, 2016. 103: p. 359-367. 309. International Organization for Standardization, in ISO 14242-1:2002, Implants for surgery -- Wear of total hip-joint prostheses -- Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test. 2002. 310. International Organization for Standardization, ISO 14243-3:2004, in Implants for surgery - Wear of total knee-joint prostheses - Part 3: Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test 2004. 2004. 311. Kestin, J., H.E. Khalifa, and R.J. Correia, Tables of the dynamic and kinematic viscosity of aqueous NaCl solutions in the temperature range 20–150 C and the pressure range 0.1–35 MPa. Journal of Physical and Chemical Reference Data, 1981. 10(1): p. 71-88. 312. Ponthiaux, P., et al., Electrochemical techniques for studying tribocorrosion processes. Wear, 2004. 256(5): p. 459-468. 313. ASTM International, in ASTM Standard G 3–89, Standard Method for Conventions Applicable to Electrochemical Measurements in Corrosion Testing, Annual Book of ASTM Standards. 2006, ASTM International: West Conshohocken, PA. 314. Bellezze, T., G. Giuliani, and G. Roventi, Study of stainless steels corrosion in a strong acid mixture. Part 1: cyclic potentiodynamic polarization curves examined by means of an analytical method. Corrosion Science, 2018. 130: p. 113-125. 315. Landolt, D., et al., Third body effects and material fluxes in tribocorrosion systems involving a sliding contact. Wear, 2004. 256(5): p. 517-524. 316. Yan, Y., et al., Tribocorrosion in implants—assessing high carbon and low carbon Co–Cr–Mo alloys by in situ electrochemical measurements. Tribology International, 2006. 39(12): p. 1509-1517. 317. Hsu, R., et al., Electrochemical corrosion studies on Co–Cr–Mo implant alloy in biological solutions. Materials Chemistry and Physics, 2005. 93: p. 531-538. 318. Pocock, G. and C.D. Richards, The human body: an introduction for the biomedical and health sciences. 2009: Oxford University Press. 319. Thornley, B., et al., Investigation into the Repassivation Process of CoCrMo in a Simulated Biological Environment. CORROSION, 2020. 76. 320. Moulder, J.F. and J. Chastain, Handbook of X-ray Photoelectron Spectroscopy: A Reference Book of Standard Spectra for Identification and Interpretation of XPS Data. 1992: Physical Electronics Division, Perkin-Elmer Corporation. 321. Cooper, H.J., et al., Adverse Local Tissue Reaction Arising from Corrosion at the Femoral Neck-Body Junction in a Dual-Taper Stem with a Cobalt-Chromium Modular Neck. The Journal of Bone and Joint Surgery. American volume, 2013. 95(10): p. 865-872. 322. Windecker, R., et al., Testing micro devices with fringe projection and white-light interferometry. Optics and Lasers in Engineering, 2001. 36(2): p. 141-154. 323. Archard, J.F., Contact and Rubbing of Flat Surfaces. Journal of Applied Physics, 1953. 24(8): p. 981-988. 324. Sinnett-Jones, P.E., J.A. Wharton, and R.J.K. Wood, Micro-abrasion–corrosion of a CoCrMo alloy in simulated artificial hip joint environments. Wear, 2005. 259(7): p. 898-909. 325. Hutchings, I. and P. Shipway, Tribology: Friction and wear of engineering materials: Second Edition. 2017. 1-388. 326. Wood, R.J.K., et al., Electrostatic monitoring of the effects of carbon black on lubricated steel/steel sliding contacts, in Tribology and Interface Engineering Series, D. Dowson, et al., Editors. 2005, Elsevier. p. 109-121. 327. Stack, M.M., M.T. Mathew, and C. Hodge, Micro-abrasion–corrosion interactions of Ni–Cr/WC based coatings: Approaches to construction of tribo-corrosion maps for the abrasion–corrosion synergism. Electrochimica Acta, 2011. 56(24): p. 8249-8259. 328. Stack, M.M., et al., Some views on the construction of bio-tribo-corrosion maps for Titanium alloys in Hank's solution: Particle concentration and applied loads effects. Tribology International, 2011. 44(12): p. 1827-1837. 329. Di Puccio, F. and L. Mattei, Biotribology of artificial hip joints. World journal of orthopedics, 2015. 6(1): p. 77-94. 330. Steinberger, R., et al., Oxygen accumulation on metal surfaces investigated by XPS, AES and LEIS, an issue for sputter depth profiling under UHV conditions. Applied Surface Science, 2017. 411: p. 189-196. 331. Jenko, M., et al., Surface chemistry and microstructure of metallic biomaterials for hip and knee endoprostheses. Applied Surface Science, 2018. 427: p. 584-593. 332. Ray, S. and A.G. Shard, Quantitative analysis of adsorbed proteins by X-ray photoelectron spectroscopy. Anal Chem, 2011. 83(22): p. 8659-66. 333. Vanea, E. and V. Simon, XPS study of protein adsorption onto nanocrystalline aluminosilicate microparticles. Applied Surface Science, 2011. 257(6): p. 2346-2352. 334. Sera Laboratories International Ltd., Certificate of Analysis, in Product: Foetal Bovine Serum European Grade. 2017: Colombia. 335. Van Doveren, H. and J.A.T.H. Verhoeven, XPS spectra of Ca, Sr, Ba and their oxides. Journal of Electron Spectroscopy and Related Phenomena, 1980. 21(3): p. 265-273. 336. Hanawa, T. and M. Ota, Calcium phosphate naturally formed on titanium in electrolyte solution. Biomaterials, 1991. 12(8): p. 767-74. 337. Demri, B. and D. Muster, XPS study of some calcium compounds. Journal of Materials Processing Technology, 1995. 55(3): p. 311-314. 338. Watson, I.M., J.A. Connor, and R. Whyman, Non-crystalline chromium, molybdenum and tungsten phosphate films prepared by metal organic chemical vapour deposition. Thin Solid Films, 1991. 201(2): p. 337-349. 339. Moffat, T.P., R.M. Latanision, and R.R. Ruf, An X-ray photoelectron spectroscopy study of chromium-metalloid alloys—III. Electrochimica Acta, 1995. 40(11): p. 1723-1734. 340. Di Laura, A., et al., The Chemical Form of Metal Species Released from Corroded Taper Junctions of Hip Implants: Synchrotron Analysis of Patient Tissue. Scientific Reports, 2017. 7(1): p. 10952. 341. Payne, B.P., M.C. Biesinger, and N.S. McIntyre, Use of oxygen/nickel ratios in the XPS characterisation of oxide phases on nickel metal and nickel alloy surfaces. Journal of Electron Spectroscopy and Related Phenomena, 2012. 185(5): p. 159-166. 342. Guo, L.Q., et al., Effect of hydrogen on semiconductive properties of passive film on ferrite and austenite phases in a duplex stainless steel. Scientific Reports, 2017. 7(1): p. 3317. 343. Honna, M., et al., Effect of friction stroke length on damage and restoration of the passive film of cobalt chromium alloy. Kitasato Med J, 2017. 47: p. 10-16. 344. Donnet, C., et al., Super-low friction of MoS2 coatings in various environments. Tribology International, 1996. 29(2): p. 123-128. 345. Farr, J.P.G., Molybdenum disulphide in lubrication. A review. Wear, 1975. 35(1): p. 1-22. 346. Catelas, I., M.A. Wimmer, and S. Utzschneider, Polyethylene and metal wear particles: characteristics and biological effects. Seminars in Immunopathology, 2011. 33(3): p. 257-271. 347. Ito, H., et al., Reduction of polyethylene wear by concave dimples on the frictional surface in artificial hip joints. J Arthroplasty, 2000. 15(3): p. 332-8. 348. Lee, R., et al., Scratch and wear performance of prosthetic femoral head components against crosslinked UHMWPE sockets. Wear, 2009. 267(11): p. 1915-1921. 349. Peaker, A.J.S. and J. Czernuszka, The Effect of Electric Field on the Formation of Hydroxyapatite Coatings. Vol. 287. 1996. 174–183. 350. Neville, A., T. Hodgkiess, and A.P. Morizot, Surface scales in sea water systems: Effects of their formation on corrosion behaviour of engineering steels. British Corrosion Journal, 1997. 32(4): p. 277-282. 351. Zhang, X. and M. Cresswell, Chapter 6 - Calcium Phosphate Materials for Controlled Release Systems, in Inorganic Controlled Release Technology, X. Zhang and M. Cresswell, Editors. 2016, Butterworth-Heinemann: Boston. p. 161-187. 352. Shin, J.W., G.R. Stafford, and K.R. Hebert, Stress in aluminum induced by hydrogen absorption during cathodic polarization. Corrosion Science, 2015. 98: p. 366-371. 353. Stankovich, M.T. and A.J. Bard, The electrochemistry of proteins and related substances part III. Bovine serum albumin. Journal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1978. 86(1): p. 189-199. 354. Kocijan, A., et al., Electrochemical Study of Co-Based Alloys in Simulated Physiological Solution. Journal of Applied Electrochemistry, 2004. 34(5): p. 517-524. 355. Moreto, J., et al., Effect of Temperature, Electrolyte Composition and Immersion Time on the Electrochemical Corrosion Behavior of CoCrMo Implant Alloy Exposed to Physiological Serum and Hank's Solution. Materials Research, 2018. 21. 356. Perret, J., et al., EBSD, SEM and FIB characterisation of subsurface deformation during tribocorrosion of stainless steel in sulphuric acid. Wear, 2010. 269(5): p. 383-393. 357. Bidiville, A., et al., Effect of surface chemistry on the mechanical response of metals in sliding tribocorrosion systems. Wear, 2007. 263(1): p. 207-217. 358. Wang, Z., et al., Effect of proteins on the surface microstructure evolution of a CoCrMo alloy in bio-tribocorrosion processes. Colloids and Surfaces B: Biointerfaces, 2016. 145: p. 176-184. 359. Wimmer, M., et al., Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2006. 220(2): p. 219-227. 360. Sun, D., J.A. Wharton, and R.J.K. Wood, Micro-abrasion mechanisms of cast CoCrMo in simulated body fluids. Wear, 2009. 267(11): p. 1845-1855. 361. Valero Vidal, C. and A. Igual Muñoz, Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluids. Corrosion Science, 2008. 50(7): p. 1954-1961. 362. Luo, L., et al., Effect of cobalt and chromium ions on MMP-1, TIMP-1, and TNF-α gene expression in human U937 macrophages: A role for tyrosine kinases. Biomaterials, 2005. 26(28): p. 5587-5593. 363. Dufils, J., et al., Influence of molybdate ion and pH on the fretting corrosion of a CoCrMo – Titanium alloy couple. Biotribology, 2017. 11: p. 20-28. 364. Talha, M., et al., Role of protein adsorption in the bio corrosion of metallic implants – A review. Colloids and Surfaces B: Biointerfaces, 2019. 176: p. 494-506. 365. Landolt, D., S. Mischler, and M. Stemp, Electrochemical methods in tribocorrosion: a critical appraisal. Electrochimica Acta, 2001. 46(24): p. 3913-3929. 366. Barril, S., S. Mischler, and D. Landolt, Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution. Wear, 2005. 259(1): p. 282-291. 367. Favero, M., P. Stadelmann, and S. Mischler, Effect of the applied potential of the near surface microstructure of a 316L steel submitted to tribocorrosion in sulfuric acid. Journal of Physics D: Applied Physics, 2006. 39: p. 3175-3183. 368. Guadalupe Maldonado, S., et al., Mechanical and chemical mechanisms in the tribocorrosion of a Stellite type alloy. Wear, 2013. 308(1): p. 213-221. 369. Neville, A., et al., Incorporating corrosion measurement in hip wear simulators: An added complication or a necessity? 2016. 230(5): p. 406-420. 370. Yan, Y., et al., Real-time corrosion measurements to assess biotribocorrosion mechanisms with a hip simulator. Tribology International, 2013. 63: p. 115-122."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.837091"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/29324/1/Taufiqurrakhman_M_MechanicalEng_PhD_2021.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cobalt-based metallic biomaterials are mostly employed as bearing materials for Total Hip Replacement (THR) owing to their high strength, their biocompatibility, as well as their wear and fatigue resistance. Cobalt-chromium-molybdenum (CoCrMo) alloys also have excellent passivity characteristics as an oxide layer can form on the surface spontaneously, reducing corrosion. Nevertheless, mechanical interaction, such as friction and wear, can damage the passive oxide layer and also causes metal products used in such replacements to be released into the human body. The repeated removal of the oxide layer due to joint articulation leads to wear and corrosion; a process termed ‘tribocorrosion’. Due to the complex working environment, as well as the presence of organic elements or species, there remains a lack of knowledge regarding tribocorrosion and the surface film mechanisms. An understanding upon these mechanisms is important since studies have reported that the tribochemical film, a complex metal-protein compound, can enhance the surface protection towards tribocorrosive processes. However, the behaviour is still debatable depending on the working conditions (e.g. temperature, pH, contact load and organic species in the lubricant). The fundamental mechanisms of wear and corrosion are recognised to solve the longevity problem of the orthopaedic implants. Tribocorrosion and tribochemistry of CoCrMo alloys were investigated in various conditions. A reciprocating tribometer, electrochemical cells and surface analysis techniques were employed to observe the tribocorrosive behaviour of CoCrMo samples tested in protein-containing electrolytes. Conditions were applied to investigate various protein-metal interactions regarding behaviour in the tribocorrosion process: (a) in a range of electrochemical potential, (b) with different organic species, (c) protein conditions and (d) with the addition of metal ions in the bulk electrolytes. Results highlighted that a tribocorrosion and tribochemical reactions occurred during sliding are sensitive to the electrolyte composition. These findings contribute to the pre-clinical understanding of protein-metal interactions occurring in tribofilms’ formation and the system variables effect on the metallic bearing surfaces."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Tribocorrosion and tribochemistry of cobalt-chromium alloy used for total hip replacement"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bryant, Michael"],"dc:contributor.sponsor":["Indonesia Endowment Fund for Education (LPDP)"],"dc:creator":["Taufiqurrakhman, Mohamad"],"dc:date":["2021-05"],"dc:date.issued":["2021-05"],"dc:description.abstract":["Cobalt-based metallic biomaterials are mostly employed as bearing materials for Total Hip Replacement (THR) owing to their high strength, their biocompatibility, as well as their wear and fatigue resistance. Cobalt-chromium-molybdenum (CoCrMo) alloys also have excellent passivity characteristics as an oxide layer can form on the surface spontaneously, reducing corrosion. Nevertheless, mechanical interaction, such as friction and wear, can damage the passive oxide layer and also causes metal products used in such replacements to be released into the human body. The repeated removal of the oxide layer due to joint articulation leads to wear and corrosion; a process termed ‘tribocorrosion’. Due to the complex working environment, as well as the presence of organic elements or species, there remains a lack of knowledge regarding tribocorrosion and the surface film mechanisms. An understanding upon these mechanisms is important since studies have reported that the tribochemical film, a complex metal-protein compound, can enhance the surface protection towards tribocorrosive processes. However, the behaviour is still debatable depending on the working conditions (e.g. temperature, pH, contact load and organic species in the lubricant). The fundamental mechanisms of wear and corrosion are recognised to solve the longevity problem of the orthopaedic implants. Tribocorrosion and tribochemistry of CoCrMo alloys were investigated in various conditions. A reciprocating tribometer, electrochemical cells and surface analysis techniques were employed to observe the tribocorrosive behaviour of CoCrMo samples tested in protein-containing electrolytes. Conditions were applied to investigate various protein-metal interactions regarding behaviour in the tribocorrosion process: (a) in a range of electrochemical potential, (b) with different organic species, (c) protein conditions and (d) with the addition of metal ions in the bulk electrolytes. Results highlighted that a tribocorrosion and tribochemical reactions occurred during sliding are sensitive to the electrolyte composition. These findings contribute to the pre-clinical understanding of protein-metal interactions occurring in tribofilms’ formation and the system variables effect on the metallic bearing surfaces."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.837091"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/29324/1/Taufiqurrakhman_M_MechanicalEng_PhD_2021.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Mechanical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/29324/"],"dc:relation.references":["1. Taufiqurrakhman, M., M. Bryant, and A. Neville, Tribofilms on CoCrMo alloys: Understanding the role of the lubricant. Biotribology, 2019: p. 100104. 2. Hip Replacement. 2019 [cited 2020 30 September]; Available from: https://www.nhs.uk/conditions/hip-replacement/. 3. OECD, Hip and knee replacement. 2017. 4. Jared R. H. Foran, M., FAAOS. Total Hip Replacement. OrthoInfo 2020 June [cited 2020 1 October 2020]; Available from: https://orthoinfo.aaos.org/en/treatment/total-hip-replacement. 5. National Joint Registry 17th Annual Report 2020. 2020, National Joint Registry. 6. Grigoris, P., P. Roberts, and K. Panousis, The development of the DuromTM metal-on-metal hip resurfacing. Hip Int, 2006. 16 Suppl 4: p. 65-72. 7. Drummond, J., P. Tran, and C. Fary, Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management. Journal of functional biomaterials, 2015. 6(3): p. 486-499. 8. Yan, Y., et al., Tribofilm formation in biotribocorrosion – does it regulate ion release in metal-on-metal artificial hip joints? Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2010. 224(9): p. 997-1006. 9. Fan, J., et al., Synovial fluid lubrication of artificial joints: protein film formation and composition. Faraday Discussions, 2012. 156: p. 69-85. 10. Hesketh, J., et al., The composition of tribofilms produced on metal-on-metal hip bearings. Biomaterials, 2014. 35(7): p. 2113-2119. 11. Espallargas, N., et al., In-situ generated tribomaterial in metal/metal contacts: Current understanding and future implications for implants. Biotribology, 2017. 10(Supplement C): p. 42-50. 12. Liao, Y., et al., Graphitic Tribological Layers in Metal-on-Metal Hip Replacements. Science, 2011. 334(6063): p. 1687-1690. 13. Liao, Y., et al., CoCrMo Metal-on-Metal Hip Replacements. Physical chemistry chemical physics : PCCP, 2013. 15(3): p. 10.1039/c2cp42968c. 14. Williams, D.F., Definitions in biomaterials. 1987, Amsterdam: Elsevier. 72. 15. Ghalme, S., A. Mankar, and Y. Bhalerao, Biomaterials in Hip Joint Replacement. Vol. 4. 2016. 113-125. 16. Navarro, M., et al., Biomaterials in orthopaedics. Journal of the Royal Society Interface, 2008. 5(27): p. 1137-1158. 17. Smith-Petersen, M.N., Evolution of mould arthroplasty of the hip joint. J Bone Joint Surg Br, 1948. 30b(1): p. 59-75. 18. Wiles, P., The surgery of the osteoarthritic hip. Br J Surg, 1958. 45(193): p. 488-97. 19. ASTM International, ASTM F138-13a, in Standard Specification for Wrought 18Chromium-14Nickel-2.5Molybdenum Stainless Steel Bar and Wire for Surgical Implants (UNS S31673). 2013: West Conshohocken, PA. 20. Metals Handbook Desk Edition, 2nd Ed, ed. J.R. Davis. 1998: ASM International. 21. Giordano, E., et al., Electrochemical behavior of two austenitic stainless steel biomaterials. Rem-revista Escola De Minas - REM-REV ESC MINAS, 2010. 63. 22. Jaimes, R., et al., New material for orthopedic implants: Electrochemical study of nickel free P558 stainless steel in minimum essential medium. Materials Letters - MATER LETT, 2010. 64: p. 1476-1479. 23. Willert, H.G., et al., Crevice corrosion of cemented titanium alloy stems in total hip replacements. Clin Orthop Relat Res, 1996(333): p. 51-75. 24. Thompson, N.G., R.A. Buchanan, and J.E. Lemons, In vitro corrosion of Ti-6Al-4V and type 316L stainless steel when galvanically coupled with carbon. Journal of Biomedical Materials Research, 1979. 13(1): p. 35-44. 25. Brown, S.R., et al., Long-term survival of McKee-Farrar total hip prostheses. Clin Orthop Relat Res, 2002(402): p. 157-63. 26. R., T.S., S. D., and L.P. D., Corrosion of cemented titanium femoral stems. The Journal of Bone and Joint Surgery. British volume, 2004. 86-B(7): p. 974-978. 27. Gomez, P.F. and J.A. Morcuende, Early Attempts at Hip Arthroplasty: 1700s to 1950s. The Iowa Orthopaedic Journal, 2005. 25: p. 25-29. 28. Charnley, J., The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br, 1972. 54(1): p. 61-76. 29. 3T PRD, Material Specification: Cobalt Chrome Alloy Co28Cr6Mo. 2013 [cited 2017 30 August]; Available from: http://www.3trpd.co.uk. 30. Milošev, I. and H.H. Strehblow, The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution. Electrochimica Acta, 2003. 48(19): p. 2767-2774. 31. Antony, K.C., Wear-Resistant Cobalt-Base Alloys. JOM, 1983. 35(2): p. 52-60. 32. Betteridge, W. Cobalt and its alloys. 1982. 33. Sumner, D.R. and J.O. Galante, Determinants of stress shielding: design versus materials versus interface. Clin Orthop Relat Res, 1992(274): p. 202-12. 34. Cottrell, S.A., An Introduction to Metallurgy. Vol. 2nd edition. 1997, Leeds, United Kingdom: Maney Publishing. 35. International Organization for Standardization, ISO 5832-4:2014, in Implants for surgery — Metallic materials — Part 4: Cobalt-chromium-molybdenum casting alloy. 2014: Berlin, Germany. 36. International Organization for Standardization, ISO 5832-12:2007, in Implants for surgery — Metallic materials — Part 12: Wrought cobalt-chromium-molybdenum alloy. 2007: Switzerland. 37. ASTM International, ASTM F75 - 12, in Standard Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Castings and Casting Alloy for Surgical Implants (UNS R30075). 2012: West Conshohocken, PA. 38. Weisse, B., et al., Failure analysis of in vivo fractured ceramic femoral heads. Engineering Failure Analysis, 2009. 16(4): p. 1188-1194. 39. Bono, J.V., et al., Revision Total Hip Arthroplasty, ed. J.V. Bono, et al. Vol. 1st edition. 1999, New York, US: Springer-Verlag New York. 40. Boutin, P., Arthroplastie totale de la hanche par prothèse en alumine frittée. Étude expérimentale et premières applications cliniques. Revue de Chirurgie Orthopédique et Traumatologique, 2014. 100(1): p. 14-21. 41. Firkins, P.J., et al., A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis. Journal of Biomechanics, 2001. 34(10): p. 1291-1298. 42. Brown, C., et al., Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation. Journal of Materials Science: Materials in Medicine, 2007. 18(5): p. 819-827. 43. Figueiredo-Pina, C.G., et al., Understanding the differences between the wear of metal-on-metal and ceramic-on-metal total hip replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2008. 222(3): p. 285-296. 44. Affatato, S., et al., Mixing and matching in ceramic-on-metal hip arthroplasty: An in-vitro hip simulator study. Journal of Biomechanics, 2009. 42(15): p. 2439-2446. 45. Williams, S., et al., Comparison of ceramic‐on‐metal and metal‐on‐metal hip prostheses under adverse conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2013. 101B(5): p. 770-775. 46. Ingham, E. and J. Fisher, Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000. 214(1): p. 21-37. 47. Masson, B., Emergence of the alumina matrix composite in total hip arthroplasty. International orthopaedics, 2009. 33(2): p. 359-363. 48. BIOLOX delta - Scientific Information and Performance Data. 2015. 49. Dowson, D. and V. Wright, Introduction to the Biomechanics of Joints and Joint Replacements. 1st Edition ed. Vol. Vol. 1. 1981, United Kingdom: Wiley–Blackwell. 50. Kumar, K.E.S. and S. Rakshit, Topology optimization of the hip bone for gait cycle. Structural and Multidisciplinary Optimization, 2020. 62(4): p. 2035-2049. 51. Glenister, R. and S. Sharma, Anatomy, bony pelvis and lower limb, hip. StatPearls [Internet], 2020. 52. Foran, J.R.H. Total Hip Replacement 2015; Available from: http://orthoinfo.aaos.org/topic.cfm?topic=a00377. 53. Singh, A.P. Synovial Fluid Composition and Functions. Available from: http://boneandspine.com/synovial-fluid/. 54. Mavraki, A. and P.M. Cann, Friction and lubricant film thickness measurements on simulated synovial fluids. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2009. 223(3): p. 325-335. 55. Roba, M., Interaction of Synovial Fluid Components with Artificial Hip-Joint Materials 2009, ETH Zurich: Zurich. 56. Yan, Y., et al., Albumin adsorption on CoCrMo alloy surfaces. Scientific reports, 2015. 5: p. 18403-18403. 57. McCarthy, J.C., J.V. Bono, and P.J. O'Donnell, Custom and modular components in primary total hip replacement. Clin Orthop Relat Res, 1997(344): p. 162-71. 58. Toomey, S.D., et al., Modular component exchange for treatment of recurrent dislocation of a total hip replacement in selected patients. J Bone Joint Surg Am, 2001. 83(10): p. 1529-33. 59. McKee, G.K. and J. Watson-Farrar, Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br, 1966. 48(2): p. 245-59. 60. Dowson, D., New joints for the Millennium: Wear control in total replacement hip joints. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001. 215(4): p. 335-358. 61. Walker, P.S. and B.L. Gold, The tribology (friction, lubrication and wear) of all-metal artificial hip joints. Wear, 1971. 17(4): p. 285-299. 62. Jones, D.A., et al., Cobalt toxicity after McKee hip arthroplasty. J Bone Joint Surg Br, 1975. 57(3): p. 289-96. 63. Charnley, J., Arthroplasty of the Hip: A New Operation. The Lancet, 1961. 277(7187): p. 1129-1132. 64. Oral, E. and O.K. Muratoglu, Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications. Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 2007. 265(1): p. 18-22. 65. Galvin, A., et al., Wear of crosslinked polyethylene under different tribological conditions. J Mater Sci Mater Med, 2006. 17(3): p. 235-43. 66. Ingham, E. and J. Fisher, The role of macrophages in osteolysis of total joint replacement. Biomaterials, 2005. 26(11): p. 1271-86. 67. Tipper, J.L., et al., Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator. Wear, 2001. 250(1): p. 120-128. 68. Rieker, C., R. Konrad, and R. Schoun, In vitro comparison of the two hard-hard articulations for total hip replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001. 215(2): p. 153-160. 69. Tipper, J.L., et al., Alumina–alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations. Biomaterials, 2002. 23(16): p. 3441-3448. 70. Kumar, P., et al., Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. J Biomed Mater Res, 1991. 25(7): p. 813-28. 71. Spinelli, M., et al., Ceramic-on-ceramic vs. metal-on-metal in total hip arthroplasty (THA): do 36-mm diameters exhibit comparable wear performance? Keramik-Keramik vs. Metall-Metall in Totalprothesen-Hüftgelenkspfanne-. Arthroplastik: zeigen 36-mm Durchmesser ähnliche Verschleißverhalten? Materialwissenschaft und Werkstofftechnik, 2009. 40(1‐2): p. 94-97. 72. Roualdes, O., et al., In vitro and in vivo evaluation of an alumina-zirconia composite for arthroplasty applications. 2010. 73. Meng, Q., et al., The lubrication performance of the ceramic-on-ceramic hip implant under starved conditions. Journal of the Mechanical Behavior of Biomedical Materials, 2015. 50: p. 70-76. 74. Vassiliou, K., S.C. Scholes, and A. Unsworth, Laboratory studies on the tribology of hard bearing hip prostheses: Ceramic on ceramic and metal on metal. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2007. 221(1): p. 11-20. 75. McMinn, D., et al., Metal on metal surface replacement of the hip. Experience of the McMinn prothesis. Clin Orthop Relat Res, 1996(329 Suppl): p. S89-98. 76. Daniel, J., P.B. Pynsent, and D.J. McMinn, Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br, 2004. 86(2): p. 177-84. 77. Ball, S.T., M.J. Le Duff, and H.C. Amstutz, Early results of conversion of a failed femoral component in hip resurfacing arthroplasty. J Bone Joint Surg Am, 2007. 89(4): p. 735-41. 78. Falez, F., et al., Results of hip resurfacing. Int Orthop, 2011. 35(2): p. 239-43. 79. McMinn, D.J.W., et al., Indications and results of hip resurfacing. International orthopaedics, 2011. 35(2): p. 231-237. 80. Knight, S.R., R. Aujla, and S.P. Biswas, Total Hip Arthroplasty - over 100 years of operative history. Orthopedic reviews, 2011. 3(2): p. e16-e16. 81. Cuckler, J.M., The rationale for metal-on-metal total hip arthroplasty. Clin Orthop Relat Res, 2005. 441: p. 132-6. 82. Archibeck, M.J., et al., The basic science of periprosthetic osteolysis. Instr Course Lect, 2001. 50: p. 185-95. 83. Boutin, P., [Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications]. Rev Chir Orthop Reparatrice Appar Mot, 1972. 58(3): p. 229-46. 84. Osborne, H., Firm pays out to NHS over defective hip replacements, in The Guardian. 2018: https://www.theguardian.com/. 85. Turner, T. Hip Replacement. 2020. 86. Eliaz, N., Corrosion of Metallic Biomaterials: A Review. Materials (Basel, Switzerland), 2019. 12(3): p. 407. 87. Balachandran, S., et al., Atomic Scale Origin of Metal Ion Release from Hip Implant Taper Junctions. Advanced Science. n/a(n/a): p. 1903008. 88. Cooper, H.J., et al., Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. The Journal of bone and joint surgery. American volume, 2012. 94(18): p. 1655-1661. 89. R., W.M., et al., Adverse local tissue reactions in metal-on-polyethylene total hip arthroplasty due to trunnion corrosion. The Bone & Joint Journal, 2015. 97-B(8): p. 1024-1030. 90. Yaszemski, M.J., Biomaterials in orthopedics. 2003: CRC Press. 91. Hill, D., Design engineering of biomaterials for medical devices. Design Engineering of Biomaterials for Medical Devices, by David Hill, pp. 480. ISBN 0-471-96708-4. Wiley-VCH, October 1998., 1998: p. 480. 92. Smith, A.J., et al., Failure rates of metal-on-metal hip resurfacings: analysis of data from the National Joint Registry for England and Wales. The Lancet, 2012. 380(9855): p. 1759-1766. 93. Roposch, A., et al., Functional Outcomes in Children with Osteonecrosis Secondary to Treatment of Developmental Dysplasia of the Hip. JBJS, 2011. 93(24): p. e145. 94. Espallargas, N., C. Torres, and A.I. Muñoz, A metal ion release study of CoCrMo exposed to corrosion and tribocorrosion conditions in simulated body fluids. Wear, 2015. 332(Supplement C): p. 669-678. 95. Muñoz, A.I. and S. Mischler, Interactive effects of albumin and phosphate ions on the corrosion of CoCrMo implant alloy. Journal of the Electrochemical Society, 2007. 154(10): p. C562-C570. 96. Vidal, C.V., et al., Passivation of a CoCrMo PVD alloy with biomedical composition under simulated physiological conditions studied by EQCM and XPS. Journal of The Electrochemical Society, 2012. 159(5): p. C233-C243. 97. Li, Y.-S., et al., Surface-enhanced Raman spectroelectrochemical studies of corrosion films on implant Co–Cr–Mo alloy in biosimulating solutions. Journal of Raman Spectroscopy, 1999. 30(2): p. 97-103. 98. Hedberg, Y. and I. Odnevall Wallinder, Metal release and speciation of released chromium from a biomedical CoCrMo alloy into simulated physiologically relevant solutions. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2014. 102(4): p. 693-699. 99. Yan, Y., D. Dowson, and A. Neville, In-situ electrochemical study of interaction of tribology and corrosion in artificial hip prosthesis simulators. Journal of the Mechanical Behavior of Biomedical Materials, 2013. 18: p. 191-199. 100. Hesketh, J., et al., Biotribocorrosion: Some electrochemical observations from an instrumented hip joint simulator. Tribology International, 2013. 59: p. 332-338. 101. Bazzoni, A., S. Mischler, and N. Espallargas, Tribocorrosion of pulsed plasma-nitrided CoCrMo implant alloy. Tribology Letters, 2013. 49(1): p. 157-167. 102. Alemón, B., et al., Tribocorrosion behavior and ions release of CoCrMo alloy coated with a TiAlVCN/CNx multilayer in simulated body fluid plus bovine serum albumin. Tribology International, 2015. 81: p. 159-168. 103. Hodgson, A.W.E., et al., Passive and transpassive behaviour of CoCrMo in simulated biological solutions. Electrochimica Acta, 2004. 49(13): p. 2167-2178. 104. Milošev, I., T. Kosec, and H.H. Strehblow, XPS and EIS study of the passive film formed on orthopaedic Ti–6Al–7Nb alloy in Hank's physiological solution. Electrochimica Acta, 2008. 53(9): p. 3547-3558. 105. Metikos-Huković, M., et al., Influence of alloying elements on the corrosion stability of CoCrMo implant alloy in Hank's solution. Acta Biomater, 2006. 2(6): p. 693-700. 106. Lhotka, C., et al., Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J Orthop Res, 2003. 21(2): p. 189-95. 107. Martin, E.J., et al., Dominant role of molybdenum in the electrochemical deposition of biological macromolecules on metallic surfaces. Langmuir, 2013. 29(15): p. 4813-4822. 108. Milošev, I., The effect of biomolecules on the behaviour of CoCrMo alloy in various simulated physiological solutions. Electrochimica Acta, 2012. 78: p. 259-273. 109. Bauer, T.W., Particles and periimplant bone resorption. Clin Orthop Relat Res, 2002(405): p. 138-43. 110. Vieira, A.C., et al., Mechanical and electrochemical deterioration mechanisms in the tribocorrosion of Al alloys in NaCl and in NaNO3 solutions. Corrosion Science, 2012. 54: p. 26-35. 111. Espallargas, N., et al., A new experimental technique for quantifying the galvanic coupling effects on stainless steel during tribocorrosion under equilibrium conditions. Wear, 2013. 307(1): p. 190-197. 112. Matusiewicz, H., Potential release of in vivo trace metals from metallic medical implants in the human body: From ions to nanoparticles – A systematic analytical review. Acta Biomaterialia, 2014. 10(6): p. 2379-2403. 113. Agency, M.a.H.p.R., Metal-on-Metal (MoM) Hip Replacements - Guidance on Implantation and Patient Management Medical Safety Alert. 2015: GOV.UK. 114. Matharu, G.S., et al., Adverse reactions to metal debris occur with all types of hip replacement not just metal-on-metal hips: a retrospective observational study of 3340 revisions for adverse reactions to metal debris from the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. BMC Musculoskelet Disord, 2016. 17(1): p. 495. 115. Doorn, P.F., et al., Tissue reaction to metal on metal total hip prostheses. Clin Orthop Relat Res, 1996(329 Suppl): p. S187-205. 116. Germain, M.A., et al., Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials, 2003. 24(3): p. 469-79. 117. Catelas, I., et al., Cytotoxic and apoptotic effects of cobalt and chromium ions on J774 macrophages - Implication of caspase-3 in the apoptotic pathway. J Mater Sci Mater Med, 2001. 12(10-12): p. 949-53. 118. Granchi, D., et al., Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res B Appl Biomater, 2006. 77(2): p. 257-64. 119. Hallab, N.J., K. Mikecz, and J.J. Jacobs, A triple assay technique for the evaluation of metal-induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty. J Biomed Mater Res, 2000. 53(5): p. 480-9. 120. Masse, A., et al., Ion release and chromosomal damage from total hip prostheses with metal-on-metal articulation. J Biomed Mater Res B Appl Biomater, 2003. 67(2): p. 750-7. 121. Willert, H.G., et al., Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am, 2005. 87(1): p. 28-36. 122. Kurtz, S.M., et al., Prevalence of Metal-on-Metal Bearings in the United States, S. Kurtz, et al., Editors. 2013, ASTM International: West Conshohocken, PA. p. 3-18. 123. Clayton, R.A., et al., Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip. A case report. J Bone Joint Surg Am, 2008. 90(9): p. 1988-93. 124. Park, Y.S., et al., Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg Am, 2005. 87(7): p. 1515-21. 125. Dobbs, H.S. and M.J. Minski, Metal ion release after total hip replacement. Biomaterials, 1980. 1(4): p. 193-198. 126. Michel, R., et al., Systemic effects of implanted prostheses made of cobalt-chromium alloys. Archives of Orthopaedic and Trauma Surgery, 1991. 110(2): p. 61-74. 127. Murgatroyd, S., Pseudotumor Presenting as a Pelvic Mass: A Complication of Eccentric Wear of a Metal on Polyethylene Hip Arthroplasty. The Journal of arthroplasty, 2011. 27: p. 820.e1-4. 128. Walsh, A.J., V.S. Nikolaou, and J. Antoniou, Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty. J Arthroplasty, 2012. 27(2): p. 324.e5-8. 129. Lyvers, M., et al., Electrochemically induced tribolayer with molybdenum for hip implants: Tribocorrosion and biocompatibility study. Thin Solid Films, 2017. 644: p. 82-91. 130. Fontana, M.G. and N.D. Greene, Corrosion Engineering. 2nd ed. ed. 1993, Japan: McGraw-Hill. 131. Talbot, D. and J. Talbot, Corrosion science and technology. 2nd ed. 2007, Boca Raton, Fla;London;: CRC Press. 132. Ratner, B.D., et al., Biomaterials science: an introduction to materials in medicine. 2004: Academic press. 133. Kamachimudali, U., T.M. Sridhar, and B. Raj, Corrosion of bio implants. Sadhana, 2003. 28(3): p. 601-637. 134. Tait, W.S., An Introduction to Electrochemical Corrosion Testing for Practicing Engineers & Scientists. 1994: Pair O Docs Pubns. 135. Bryant, M. and A. Neville, Corrosion and mechanical properties. Orthopaedics and Trauma, 2016. 30(3): p. 176-191. 136. Scully, J.R. and K. Lutton, Polarization Behavior of Active Passive Metals and Alloys, in Encyclopedia of Interfacial Chemistry, K. Wandelt, Editor. 2018, Elsevier: Oxford. p. 439-447. 137. Frankel, G.S., Pitting Corrosion of Metals: A Review of the Critical Factors. Journal of The Electrochemical Society, 1998. 145(6): p. 2186-2198. 138. Brox, B. and I. Olefjord, Preferential dissolution of iron during polarization of stainless steels in acids. Stainless Steel'84, Chalmers University of Technology, 1984: p. 134-142. 139. Milosev, I. and M. Remskar, In vivo production of nanosized metal wear debris formed by tribochemical reaction as confirmed by high-resolution TEM and XPS analyses. J Biomed Mater Res A, 2009. 91(4): p. 1100-10. 140. Kocijan, A., I. Milosev, and B. Pihlar, Cobalt-based alloys for orthopedic applications studied by electrochemical and XPS analysis. Vol. 15. 2004. 643-50. 141. Bryant, M., Fretting-crevice corrosion of cemented metal on metal total hip replacements. 2013, University of Leeds. 142. Hoar, T., The production and breakdown of the passivity of metals. Corrosion Science, 1967. 7: p. 341-355. 143. Uhlig, H.H., Adsorbed and Reaction‐Product Films on Metals. Journal of the Electrochemical Society, 1950. 97(11): p. 215C. 144. Richardson, J.A. and G.C. Wood, The Interpretation of Impedance Changes on Oxide-Coated Aluminum Produced by Immersion in Inhibitive and Corrosive Aqueous Media. Journal of The Electrochemical Society, 1973. 120(2): p. 193. 145. Pistorius, P.C. and G.T. Burstein, Metastable pitting corrosion of stainless steel and the transition to stability. Philosophical Transactions of the Royal Society of London. Series A: Physical and Engineering Sciences, 1992. 341(1662): p. 531-559. 146. ASTM International, Standard Guide for Examination and Evaluation of Pitting Corrosion, in ASTM G46-94(2013). 2013, PA: West Conshohocken. 147. Roy, A., D. Fleming, and S. Gordon. Effect of chloride concentration and pH on pitting corrosion of waste package container materials. 1996. 148. NACE. Crevice Corrosion. [cited 2017 16 August]; Available from: https://www.nace.org/Corrosion-Central/Corrosion-101/Crevice-Corrosion/. 149. Oldfield, J.W. and W.H. Sutton, New Technique for Predicting the Performance of Stainless Steels in Sea Water and other Chloride-containing Environments. British Corrosion Journal, 1980. 15(1): p. 31-34. 150. Oldfield, J.W. and W.H. Sutton, Crevice Corrosion of Stainless Steels: II. Experimental studies. British Corrosion Journal, 1978. 13(3): p. 104-111. 151. Foundation, A.E., Hip & Knee Book, in TRUNNIONOSIS. 2017: hipandkneebook.com. 152. Gilbert, J.L., C.A. Buckley, and J.J. Jacobs, In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. Journal of Biomedical Materials Research, 1993. 27(12): p. 1533-1544. 153. Gilbert, J.L., et al., Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. J Bone Joint Surg Am, 1994. 76(1): p. 110-5. 154. NACE. Galvanic Corrosion. Available from: https://www.nace.org/Corrosion-Central/Corrosion-101/Galvanic-Corrosion/. 155. Collier, J.P., et al., Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems. Clinical orthopaedics and related research, 1991(271): p. 305-312. 156. Lucas, L.C., R.A. Buchanan, and J.E. Lemons, Investigations on the galvanic corrosion of multialloy total hip prostheses. Journal of Biomedical Materials Research, 1981. 15(5): p. 731-747. 157. Serhan, H., et al., Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern? Spine J, 2004. 4(4): p. 379-87. 158. Virtanen, S., et al., Special modes of corrosion under physiological and simulated physiological conditions. Acta Biomater, 2008. 4(3): p. 468-76. 159. Mears, D.C., The use of dissimilar metals in surgery. Journal of Biomedical Materials Research, 1975. 9(4): p. 133-148. 160. Reclaru, L., et al., Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material. Biomaterials, 2002. 23(16): p. 3479-85. 161. Tan, Y., Homogeneous Electrode Models and Uniform Corrosion Measurements, in Heterogeneous Electrode Processes and Localized Corrosion, R.W. Revie, Editor. 2012, John Wiley & Sons, Inc.: New Jersey, US. p. 1-35. 162. Poursaee, A., 9 - Corrosion measurement and evaluation techniques of steel in concrete structures, in Corrosion of Steel in Concrete Structures, A. Poursaee, Editor. 2016, Woodhead Publishing: Oxford. p. 169-191. 163. Vidal, C.V., Study of the degradation mechanisms of the CoCrMo biomedical alloy in physiological media by electrochemical techniques and surface analysis. 2012, Universitat Politècnica de València. 164. Scully, J., D. Silverman, and M. Kendig, Electrochemical Impedance: Analysis and Interpretation. 1993. 165. Milošev, I., T. Kosec, and H.-H.J.E.A. Strehblow, XPS and EIS study of the passive film formed on orthopaedic Ti–6Al–7Nb alloy in Hank's physiological solution. 2008. 53(9): p. 3547-3558. 166. Moreto, J.A., et al., Effect of Temperature, Electrolyte Composition and Immersion Time on the Electrochemical Corrosion Behavior of CoCrMo Implant Alloy Exposed to Physiological Serum and Hank's Solution %J Materials Research. 2018. 21. 167. Namus, R., et al., The influence of protein concentration, temperature and cathodic polarization on the surface status of CoCrMo biomedical grade alloys. Applied Surface Science, 2020. 499: p. 143908. 168. Dambatta, M.s., et al., In vitro degradation and cell viability assessment of Zn-3Mg alloy for biodegradable bone implants. Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine, 2015. 229: p. 335-342. 169. Growcock, F.B. and R.J. Jasinski, Time‐Resolved Impedance Spectroscopy of Mild Steel in Concentrated Hydrochloric Acid. Journal of The Electrochemical Society, 1989. 136(8): p. 2310-2314. 170. Olsson, C.O.A. and D. Landolt, Anodisation of a Nb–Zr alloy. Electrochimica Acta, 2003. 48(27): p. 3999-4011. 171. Helsen, J.A. and H. Jürgen Breme, Metals as biomaterials. 1998. 172. Bommersbach, P., et al., Formation and behaviour study of an environment-friendly corrosion inhibitor by electrochemical methods. Electrochimica Acta, 2005. 51(6): p. 1076-1084. 173. STLE. [cited 2017 01 August]; Available from: http://www.stle.org/files/What_is_tribology/Tribology_Applications.aspx. 174. Gohar, R. and H. Rahnejat, Fundamentals of tribology. 2nd ed. 2012, London: Imperial College Press. 175. Stachowiak, G.W. and A.W. Batchelor, Engineering tribology. Fourth;4;4th; ed. 2014, Oxford: Butterworth-Heinemann. 176. Singer, I., Surface Analysis, in Handbook of Lubrication and Tribology, Volume II. 2012, CRC Press. p. 1-20. 177. Greenwood, J.A. and J.B.P. Williamson, Contact of nominally flat surfaces. Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences, 1966. 295(1442): p. 300. 178. Shigley, J.E., Mechanical Engineering Design. 5th Edition, Chapter 2 ed. 1989: McGraw-Hill, Inc. 179. Williams, J.A., Engineering tribology. 1994, Oxford: Oxford University Press. 180. Hertz, H., On the Contact of Elastic Solids. J Reine Angew Math, 1881. 92: p. 156-171. 181. Archard, J.F. and T.E. Allibone, Elastic deformation and the laws of friction. Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences, 1957. 243(1233): p. 190-205. 182. Williams, J., Engineering tribology. 2005: Cambridge University Press. 183. Moore, J., et al. Mechanics Map - Open Textbook Project. Engineering Mechanic [cited 2020 2 October]; Available from: http://mechanicsmap.psu.edu/websites/6_friction/dry_friction/dryfriction.html. 184. Association, A.B., The Principles and Design of Foundation Brake Rigging. 1921: Air brake association. 185. Hanaor, D.A.H., Y. Gan, and I. Einav, Static friction at fractal interfaces. Tribology International, 2016. 93: p. 229-238. 186. Yan, Y., Corrosion and Tribo-Corrosion Behaviour of Metallic Orthopaedic Implant Materials. 2006, University of Leeds. 187. Flugsrud, G.B., et al., The effect of middle-age body weight and physical activity on the risk of early revision hip arthroplasty: A cohort study of 1,535 individuals. Acta Orthopaedica, 2007. 78(1): p. 99-107. 188. Damm, P., et al., Friction in Total Hip Joint Prosthesis Measured In Vivo during Walking. PloS one, 2013. 8: p. e78373. 189. Affatato, S., 7 - Tribological interactions of modern biomaterials used in total hip arthroplasty (THA), in Perspectives in Total Hip Arthroplasty, S. Affatato, Editor. 2014, Woodhead Publishing. p. 99-116. 190. Totten, G.E. and H. Liang, Mechanical Tribology. 2004, New York: Marcel Dekker, Inc. 191. Stachowiak, G.W., Wear-materials, mechanisms and practice. 2005, Chichester: Wiley. 192. Stachowiak, G.W. and A.W. Batchelor, Engineering tribology. 3rd;3; ed. 2005, Amsterdam;Boston;: Elsevier Butterworth-Heinemann. 193. Stachowiak, G.W. and A.W. Batchelor, 13 - Corrosive and Oxidative Wear, in Engineering Tribology (Third Edition). 2006, Butterworth-Heinemann: Burlington. p. 573-593. 194. Vingsbo, O. and S. Söderberg, On fretting maps. Wear, 1988. 126(2): p. 131-147. 195. Bryant, M., et al., Galvanically enhanced fretting-crevice corrosion of cemented femoral stems. Journal of the Mechanical Behavior of Biomedical Materials, 2014. 40: p. 275-286. 196. Oladokun, A., Mechanism of Fretting Corrosion at the Modular Taper Interface of Hip Prosthesis. 2017, University of Leeds. 197. Kondo, Y., T. Koyama, and S. Sasaki, Tribological Properties of Ionic Liquids, in Ionic Liquids - New Aspects for the Future, J.-i. Kadokawa, Editor. 2013, InTech: Rijeka. p. Ch. 05. 198. Neville, A.a.M., A., Wear and Chemistry of Lubricants, in Wear: Materials, Mechanisms and Practice, G.W. Stachowiak, Editor. 2005, John Wiley & Sons: Hoboken. p. 71–94. 199. Beadling, A.R., Biotribocorrosion of Hard-on-Hard Bearing Surfaces in Orthopaedic Hip Replacements. 2016, University of Leeds. 200. Jin, Z., et al., Analysis and modelling of wear of cobalt-chrome alloys in a pin-on-plate test for a metal-on-metal total hip replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2000. 214(6): p. 559-568. 201. Sonntag, R., et al., Hard-on-hard lubrication in the artificial hip under dynamic loading conditions. PloS one, 2013. 8(8): p. e71622-e71622. 202. Jalali-Vahid, D., et al., Prediction of lubricating film thickness in UHMWPE hip joint replacements. J Biomech, 2001. 34(2): p. 261-6. 203. Khaemba, D.N., Raman spectroscopic studies of friction modifier Molybdenum DialkyldiThioCarbamate (MoDTC). 2016, University of Leeds. 204. Mischler, S., Triboelectrochemical techniques and interpretation methods in tribocorrosion: A comparative evaluation. Tribology International, 2008. 41(7): p. 573-583. 205. López-Ortega, A., J.L. Arana, and R. Bayón, Tribocorrosion of Passive Materials: A Review on Test Procedures and Standards. International Journal of Corrosion, 2018. 2018: p. 7345346. 206. Mathew, M.T., et al., Significance of Tribocorrosion in Biomedical Applications: Overview and Current Status. Advances in Tribology, 2009. 2009: p. 250986. 207. Landolt, D. and S. Mischler, Tribocorrosion of passive metals and coatings. 2011: Elsevier. 208. Watson, S.W., et al., Methods of measuring wear-corrosion synergism. Wear, 1995. 181-183: p. 476-484. 209. Landolt, D., Electrochemical and materials aspects of tribocorrosion systems. Journal of Physics D: Applied Physics, 2006. 39(15): p. 3121-3127. 210. Diomidis, N., et al., Tribocorrosion of stainless steel in sulfuric acid: Identification of corrosion-wear components and effect of contact area. Vol. 269. 2010. 93-103. 211. Mischler, S. and P. Ponthiaux, A round robin on combined electrochemical and friction tests on alumina/stainless steel contacts in sulphuric acid. Wear, 2001. 248(1): p. 211-225. 212. Fuentes, E., et al., Advanced Surface Treatments on Titanium and Titanium Alloys Focused on Electrochemical and Physical Technologies for Biomedical Applications, in Biomaterial-supported Tissue Reconstruction or Regeneration. 2019. 213. Vieira, A., et al., Mechanical and electrochemical deterioration mechanisms in the tribocorrosion of Al alloys in NaCl and in NaNO 3 solutions. Corrosion Science, 2012. 54: p. 26-35. 214. Igual Muñoz, A. and N. Espallargas, 5 - Tribocorrosion mechanisms in sliding contacts, in Tribocorrosion of Passive Metals and Coatings, D. Landolt and S. Mischler, Editors. 2011, Woodhead Publishing. p. 118-152. 215. ASTM International, ASTM G119-06, in Standard Guide for Determining Synergism Between Wear and Corrosion. 2016, ASTM International: West Conshohocken, PA. 216. Yan, Y., 7 - Growth of passive tribofilms in medical implants, in Bio-Tribocorrosion in Biomaterials and Medical Implants. 2013, Woodhead Publishing. p. 147-168. 217. Zhang, Y., X.-Y. Yin, and F.-Y. Yan, Tribocorrosion behaviour of type S31254 steel in seawater: Identification of corrosion–wear components and effect of potential. Materials Chemistry and Physics, 2016. 179: p. 273-281. 218. Ma, F., et al., Structural, mechanical and tribocorrosion behaviour in artificial seawater of CrN/AlN nano-multilayer coatings on F690 steel substrates. Applied Surface Science, 2018. 428: p. 404-414. 219. Priya, R., C. Mallika, and U.K. Mudali, Wear and tribocorrosion behaviour of 304L SS, Zr-702, Zircaloy-4 and Ti-grade2. Wear, 2014. 310(1): p. 90-100. 220. Stack, M.M. and G.H. Abdulrahman, Mapping erosion-corrosion of carbon steel in oil exploration conditions: Some new approaches to characterizing mechanisms and synergies. Tribology International, 2010. 43(7): p. 1268-1277. 221. Mathew, M.T., et al., Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: A comparison between two testing systems. Wear, 2011. 271(9): p. 1210-1219. 222. UNE 112086:2016, in Tribocorrosion testing procedure for passivating materials. 2016, Asociación Española de Normalización (UNE). 223. Bryant, M. and A. Neville, Fretting corrosion of CoCr alloy: Effect of load and displacement on the degradation mechanisms. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2017. 231(2): p. 114-126. 224. Mischler, S., et al., Influence of passivity on the tribocorrosion of carbon steel in aqueous solutions. Wear, 2001. 251(1): p. 1295-1307. 225. Godet, M., The third-body approach: A mechanical view of wear. Wear, 1984. 100(1): p. 437-452. 226. Vinothkumar, K.R. and R. Henderson, Structures of membrane proteins. Quarterly reviews of biophysics, 2010. 43(1): p. 65-158. 227. Protein Concept Map. 2003: Pearson Education, Inc., publishing as Benjamin Cummings. 228. Protein-Surface Interactions, in An Introduction To Tissue‐Biomaterial Interactions. 2002. p. 37-52. 229. Maskiewicz, V.K., et al., Characterization of protein degradation in serum-based lubricants during simulation wear testing of metal-on-metal hip prostheses. J Biomed Mater Res B Appl Biomater, 2010. 94(2): p. 429-40. 230. Parkes, M., et al., The effect of buffer solution choice on protein adsorption and lubrication. Tribology International, 2014. 72: p. 108-117. 231. Malvern Panalytical. Using Raman Spectroscopy to Understand the Conformational Stability of Protein Therapeutics. AZoM, viewed 15 January 2020. viewed 15 January 2020; Available from: https://www.azom.com/article.aspx?ArticleID=11142. 232. Foley, S., et al., Photolysis of Bovine Serum Albumin by near UV irradiation. 2011. 233. Lewis, E.N., et al., Combined dynamic light scattering and Raman spectroscopy approach for characterizing the aggregation of therapeutic proteins. Molecules (Basel, Switzerland), 2014. 19(12): p. 20888-20905. 234. Thawornchinsombut, S., et al., Raman Spectroscopy Determines Structural Changes Associated with Gelation Properties of Fish Proteins Recovered at Alkaline pH. Journal of Agricultural and Food Chemistry, 2006. 54(6): p. 2178-2187. 235. Zhang, S., et al., Raman Spectroscopic Characterization of Structural Changes in Heated Whey Protein Isolate upon Soluble Complex Formation with Pectin at Near Neutral pH. Journal of Agricultural and Food Chemistry, 2012. 60(48): p. 12029-12035. 236. Wang, C.-H., et al., The effect of disulfide bonds on protein folding, unfolding, and misfolding investigated by FT–Raman spectroscopy. Journal of Raman Spectroscopy, 2016. 47(8): p. 940-947. 237. Chen, M.C. and R.C. Lord, Laser-excited Raman spectroscopy of biomolecules. VIII. Conformational study of bovine serum albumin. J Am Chem Soc, 1976. 98(4): p. 990-2. 238. Wesełucha-Birczyńska, A., et al., Raman micro-spectroscopy tracing human lymphocyte activation. The Analyst, 2013. 138. 239. Esmonde-White, K.A., et al., Raman spectroscopy of synovial fluid as a tool for diagnosing osteoarthritis. J Biomed Opt, 2009. 14(3): p. 034013. 240. Lin, V.J.C. and J.L. Koenig, Raman studies of bovine serum albumin. Biopolymers, 1976. 15(1): p. 203-218. 241. Liang, M., et al., A simple and direct isolation of whey components from raw milk by gel filtration chromatography and structural characterization by Fourier transform Raman spectroscopy. Talanta, 2006. 69(5): p. 1269-1277. 242. Qian, W. and S. Krimm, Vibrational studies of the disulfide group in proteins. VII. Normal mode analysis of the Raman spectra of erabutoxin, γ‐II crystallin and immunoglobulin. Journal of Raman spectroscopy, 1992. 23(10): p. 517-521. 243. Hedberg, Y., et al., Surface-protein interactions on different stainless steel grades: effects of protein adsorption, surface changes and metal release. Journal of Materials Science: Materials in Medicine, 2013. 24(4): p. 1015-1033. 244. Oates, K.M.N., et al., Rheopexy of synovial fluid and protein aggregation. Journal of the Royal Society, Interface, 2006. 3(6): p. 167-174. 245. Merritt, K., S.A. Brown, and N.A. Sharkey, The binding of metal salts and corrosion products to cells and proteins in vitro. Journal of Biomedical Materials Research, 1984. 18(9): p. 1005-1015. 246. Horbett, T.A., The role of adsorbed proteins in tissue response to biomaterials, in Biomaterials Science. 2004, Elsevier Academic Press: London. 247. Hlady, V. and J. Buijs, Protein adsorption on solid surfaces. Current Opinion in Biotechnology, 1996. 7(1): p. 72-77. 248. Gray, J.J., The interaction of proteins with solid surfaces. Current Opinion in Structural Biology, 2004. 14(1): p. 110-115. 249. Kopac, T., K. Bozgeyik, and J. Yener, Effect of pH and temperature on the adsorption of bovine serum albumin onto titanium dioxide. Colloids and Surfaces A: Physicochemical and Engineering Aspects, 2008. 322(1): p. 19-28. 250. Wang, Z., Y. Yan, and L. Qiao, Protein adsorption on implant metals with various deformed surfaces. Colloids and Surfaces B: Biointerfaces, 2017. 156: p. 62-70. 251. Valero Vidal, C., A. Olmo Juan, and A. Igual Muñoz, Adsorption of bovine serum albumin on CoCrMo surface: Effect of temperature and protein concentration. Colloids and Surfaces B: Biointerfaces, 2010. 80(1): p. 1-11. 252. Zhu, J., N. Xu, and C. Zhang, Characteristics of copper corrosion in simulated uterine fluid in the presence of protein. Advances in contraception, 1999. 15(3): p. 179-190. 253. Li, J., et al., Comparison of the release behaviors of cupric ions from metallic copper and a novel composite in simulated body fluid. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2008. 85B(1): p. 172-179. 254. Ithurbide, A., et al., XPS and flow-cell EQCM study of albumin adsorption on passivated chromium surfaces: Influence of potential and pH. Electrochimica Acta, 2007. 53(3): p. 1336-1345. 255. Valero-Vidal, C., et al., Adsorption of BSA on Passivated CoCrMo PVD Alloy: An EQCM and XPS Investigation. Journal of The Electrochemical Society, 2014. 161(6): p. C294-C301. 256. Wagner, M.S., T.A. Horbett, and D.G. Castner, Characterizing multicomponent adsorbed protein films using electron spectroscopy for chemical analysis, time-of-flight secondary ion mass spectrometry, and radiolabeling: capabilities and limitations. Biomaterials, 2003. 24(11): p. 1897-1908. 257. Muñoz, A.I. and S. Mischler, Electrochemical Quartz Crystal Microbalance and X-Ray Photoelectron Spectroscopy study of cathodic reactions in Bovine Serum Albumin containing solutions on a Physical Vapour Deposition-CoCrMo biomedical alloy. Electrochimica Acta, 2015. 180(Supplement C): p. 96-103. 258. Munoz, A.I. and S. Mischler, Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys. J Mater Sci Mater Med, 2011. 22(3): p. 437-50. 259. Yan, Y., A. Neville, and D. Dowson, Biotribocorrosion of CoCrMo orthopaedic implant materials - Assessing the formation and effectof the biofilm. Tribology International, 2007. 40(10-12): p. 1492-1499. 260. Williams, D.F., I.N. Askill, and R. Smith, Protein absorption and desorption phenomena on clean metal surfaces. J Biomed Mater Res, 1985. 19(3): p. 313-20. 261. Contu, F., B. Elsener, and H. Bohni, Characterization of implant materials in fetal bovine serum and sodium sulfate by electrochemical impedance spectroscopy. II. Coarsely sandblasted samples. J Biomed Mater Res A, 2003. 67(1): p. 246-54. 262. Kerwell, S., et al., Electrochemically Induced Film Formation on CoCrMo Alloy for Hip Implant Application. Vol. 3. 2017. 263. Hedberg, Y., Role of proteins in the degradation of relatively inert alloys inthe human body. 2018. 2. 264. Yang, J. and J. Black, Competitive binding of chromium, cobalt and nickel to serum proteins. Biomaterials, 1994. 15(4): p. 262-268. 265. Hallab, N.J., et al., Systemic metal–protein binding associated with total joint replacement arthroplasty. Journal of Biomedical Materials Research, 2000. 49(3): p. 353-361. 266. Jacobs, J.J., et al., Metal degradation products: a cause for concern in metal-metal bearings? Clin Orthop Relat Res, 2003(417): p. 139-47. 267. Hedberg, Y.S., Role of proteins in the degradation of relatively inert alloys in the human body. npj Materials Degradation, 2018. 2(1): p. 26. 268. Thompson, C., et al., Impact of Magnetic Stirring on Stainless Steel Integrity: Effect on Biopharmaceutical Processing. J Pharm Sci, 2017. 106(11): p. 3280-3286. 269. Rosenberg, A.S., Effects of protein aggregates: an immunologic perspective. Aaps j, 2006. 8(3): p. E501-7. 270. Hedberg, Y.S., et al., Can Cobalt(II) and Chromium(III) Ions Released from Joint Prostheses Influence the Friction Coefficient? ACS Biomaterials Science & Engineering, 2015. 1(8): p. 617-620. 271. Arenas, M., et al., Electrochemical noise measurements of AISI 316L during wear in simulated physiological media. Corrosion Engineering, Science and Technology, 2014. 49: p. 656-660. 272. Liang, M., et al., A simple and direct isolation of whey components from raw milk by gel filtration chromatography and structural characterization by Fourier transform Raman spectroscopy. Talanta, 2006. 69(5): p. 1269-1277. 273. Mishina, H. and M. Kojima, Changes in human serum albumin on arthroplasty frictional surfaces. Wear, 2008. 265(5): p. 655-663. 274. Wimmer, M.A., et al., The acting wear mechanisms on metal-on-metal hip joint bearings: in vitro results. Wear, 2001. 250(1): p. 129-139. 275. Bergmann, G., et al., High-Tech Hip Implant for Wireless Temperature Measurements In Vivo. PLOS ONE, 2012. 7(8): p. e43489. 276. Myant, C., et al., Lubrication of metal-on-metal hip joints: The effect of protein content and load on film formation and wear. Journal of the Mechanical Behavior of Biomedical Materials, 2012. 6: p. 30-40. 277. Ma, L. and W.M. Rainforth, A study of Biolox® delta subject to water lubricated reciprocating wear. Tribology International, 2010. 43(10): p. 1872-1881. 278. Li, X., et al., Depassivation–repassivation behavior of a CoCrMo alloy under Tribological contact in Simulated body Fluids. Int J Electrochem Sci, 2017. 12: p. 2495-2505. 279. Sun, D., J. Wharton, and R. Wood, The Effects of Protein and pH on the Tribo-Corrosion Performance of Cast CoCrMo — A Combined Electrochemical and Tribological Study. 2010. p. 825-826. 280. Hesketh, J.E.T., Tribocorrosion of Total Hip Replacements. 2012, University of Leeds. 281. Runa, M.J., M.T. Mathew, and L.A. Rocha, Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems. Tribology International, 2013. 68: p. 85-93. 282. Wang, Z., et al., Effect of electrochemical corrosion on the subsurface microstructure evolution of a CoCrMo alloy in albumin containing environment. Applied Surface Science, 2017. 406: p. 319-329. 283. De Motte, R., et al., Near surface pH measurements in aqueous CO2 corrosion. Electrochimica Acta, 2018. 290: p. 605-615. 284. Merritt, K. and S.A. Brown, Effect of proteins and pH on fretting corrosion and metal ion release. J Biomed Mater Res, 1988. 22(2): p. 111-20. 285. Valero Vidal, C. and A. Igual Muñoz, Effect of physico-chemical properties of simulated body fluids on the electrochemical behaviour of CoCrMo alloy. Electrochimica Acta, 2011. 56(24): p. 8239-8248. 286. Sadiq, K., M.M. Stack, and R.A. Black, Wear mapping of CoCrMo alloy in simulated bio-tribocorrosion conditions of a hip prosthesis bearing in calf serum solution. Mater Sci Eng C Mater Biol Appl, 2015. 49: p. 452-462. 287. Heinicke, G., Tribochemistry. 1984: John Wiley & Sons. 288. Hsu, S.M., J. Zhang, and Z. Yin, The Nature and Origin of Tribochemistry. Tribology Letters, 2002. 13(2): p. 131-139. 289. Fischer, T.E., Tribochemistry. Annual Review of Materials Science, 1988. 18(1): p. 303-323. 290. Adams, H.L., et al., Shear-Induced Mechanochemistry: Pushing Molecules Around. The Journal of Physical Chemistry C, 2015. 119(13): p. 7115-7123. 291. Jelita Rydel, J., R.H. Vegter, and P.E.J. Rivera-Díaz-del-Castillo, Tribochemistry of bearing steels: A new AFM method to study the material–tribofilm correlation. Tribology International, 2016. 98: p. 74-81. 292. Wan, S., et al., Tribochemistry of adaptive integrated interfaces at boundary lubricated contacts. Scientific Reports, 2017. 7(1): p. 9935. 293. Meng, Q.E., et al., Contact mechanics and lubrication analyses of ceramic-on-metal total hip replacements. Tribology International, 2013. 63: p. 51-60. 294. McEntire, B., et al., Silicon Nitride Bearings for Total Joint Arthroplasty. Lubricants, 2016. 4(4): p. 35. 295. Nečas, D., et al., The effect of lubricant constituents on lubrication mechanisms in hip joint replacements. Journal of the Mechanical Behavior of Biomedical Materials, 2016. 55: p. 295-307. 296. Vrbka, M., et al., Study of film formation in bovine serum lubricated contacts under rolling/sliding conditions. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2013. 227(5): p. 459-475. 297. Ghosh, S., et al., Tribological performance of the biological components of synovial fluid in artificial joint implants. Science and technology of advanced materials, 2015. 16(4): p. 045002-045002. 298. Wimmer, M.A., et al., Tribochemical reaction on metal-on-metal hip joint bearings - A comparison between in-vitro and in-vivo results. WEAR, 2003. 255(2): p. 1007-1014. 299. Pourzal, R., et al., Micro-structural alterations within different areas of articulating surfaces of a metal-on-metal hip resurfacing system. Wear, 2009. 267(5): p. 689-694. 300. Pourzal, R., et al., Characterization of wear particles generated from CoCrMo alloy under sliding wear conditions. Wear, 2011. 271(9): p. 1658-1666. 301. Zeng, P., et al., Subsurface characterisation of wear on mechanically polished and electro-polished biomedical grade CoCrMo. Wear, 2015. 332-333: p. 650-661. 302. Mathew, M.T., J.J. Jacobs, and M.A. Wimmer, Wear-Corrosion Synergism in a CoCrMo Hip Bearing Alloy Is Influenced by Proteins. Clinical Orthopaedics and Related Research, 2012. 470(11): p. 3109-3117. 303. Sargeant, A. and T. Goswami, Hip implants: Paper V. Physiological effects. Materials & Design, 2006. 27(4): p. 287-307. 304. Jacobs, J.J., J.L. Gilbert, and R.M. Urban, Corrosion of metal orthopaedic implants. J Bone Joint Surg Am, 1998. 80(2): p. 268-82. 305. Rabe, M., D. Verdes, and S. Seeger, Understanding protein adsorption phenomena at solid surfaces. Advances in Colloid and Interface Science, 2011. 162(1): p. 87-106. 306. Anissian, H.L., et al., The wear pattern in metal-on-metal hip prostheses. J Biomed Mater Res, 2001. 58(6): p. 673-8. 307. Smith, S.L., D. Dowson, and A.A.J. Goldsmith, The lubrication of metal-on-metal total hip joints: A slide down the Stribeck curve. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2001. 215(5): p. 483-493. 308. Beadling, A.R., et al., Tribocorrosion of hard-on-hard total hip replacements with metal and ceramic counterfaces under standard and adverse loading conditions. Tribology International, 2016. 103: p. 359-367. 309. International Organization for Standardization, in ISO 14242-1:2002, Implants for surgery -- Wear of total hip-joint prostheses -- Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test. 2002. 310. International Organization for Standardization, ISO 14243-3:2004, in Implants for surgery - Wear of total knee-joint prostheses - Part 3: Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test 2004. 2004. 311. Kestin, J., H.E. Khalifa, and R.J. Correia, Tables of the dynamic and kinematic viscosity of aqueous NaCl solutions in the temperature range 20–150 C and the pressure range 0.1–35 MPa. Journal of Physical and Chemical Reference Data, 1981. 10(1): p. 71-88. 312. Ponthiaux, P., et al., Electrochemical techniques for studying tribocorrosion processes. Wear, 2004. 256(5): p. 459-468. 313. ASTM International, in ASTM Standard G 3–89, Standard Method for Conventions Applicable to Electrochemical Measurements in Corrosion Testing, Annual Book of ASTM Standards. 2006, ASTM International: West Conshohocken, PA. 314. Bellezze, T., G. Giuliani, and G. Roventi, Study of stainless steels corrosion in a strong acid mixture. Part 1: cyclic potentiodynamic polarization curves examined by means of an analytical method. Corrosion Science, 2018. 130: p. 113-125. 315. Landolt, D., et al., Third body effects and material fluxes in tribocorrosion systems involving a sliding contact. Wear, 2004. 256(5): p. 517-524. 316. Yan, Y., et al., Tribocorrosion in implants—assessing high carbon and low carbon Co–Cr–Mo alloys by in situ electrochemical measurements. Tribology International, 2006. 39(12): p. 1509-1517. 317. Hsu, R., et al., Electrochemical corrosion studies on Co–Cr–Mo implant alloy in biological solutions. Materials Chemistry and Physics, 2005. 93: p. 531-538. 318. Pocock, G. and C.D. Richards, The human body: an introduction for the biomedical and health sciences. 2009: Oxford University Press. 319. Thornley, B., et al., Investigation into the Repassivation Process of CoCrMo in a Simulated Biological Environment. CORROSION, 2020. 76. 320. Moulder, J.F. and J. Chastain, Handbook of X-ray Photoelectron Spectroscopy: A Reference Book of Standard Spectra for Identification and Interpretation of XPS Data. 1992: Physical Electronics Division, Perkin-Elmer Corporation. 321. Cooper, H.J., et al., Adverse Local Tissue Reaction Arising from Corrosion at the Femoral Neck-Body Junction in a Dual-Taper Stem with a Cobalt-Chromium Modular Neck. The Journal of Bone and Joint Surgery. American volume, 2013. 95(10): p. 865-872. 322. Windecker, R., et al., Testing micro devices with fringe projection and white-light interferometry. Optics and Lasers in Engineering, 2001. 36(2): p. 141-154. 323. Archard, J.F., Contact and Rubbing of Flat Surfaces. Journal of Applied Physics, 1953. 24(8): p. 981-988. 324. Sinnett-Jones, P.E., J.A. Wharton, and R.J.K. Wood, Micro-abrasion–corrosion of a CoCrMo alloy in simulated artificial hip joint environments. Wear, 2005. 259(7): p. 898-909. 325. Hutchings, I. and P. Shipway, Tribology: Friction and wear of engineering materials: Second Edition. 2017. 1-388. 326. Wood, R.J.K., et al., Electrostatic monitoring of the effects of carbon black on lubricated steel/steel sliding contacts, in Tribology and Interface Engineering Series, D. Dowson, et al., Editors. 2005, Elsevier. p. 109-121. 327. Stack, M.M., M.T. Mathew, and C. Hodge, Micro-abrasion–corrosion interactions of Ni–Cr/WC based coatings: Approaches to construction of tribo-corrosion maps for the abrasion–corrosion synergism. Electrochimica Acta, 2011. 56(24): p. 8249-8259. 328. Stack, M.M., et al., Some views on the construction of bio-tribo-corrosion maps for Titanium alloys in Hank's solution: Particle concentration and applied loads effects. Tribology International, 2011. 44(12): p. 1827-1837. 329. Di Puccio, F. and L. Mattei, Biotribology of artificial hip joints. World journal of orthopedics, 2015. 6(1): p. 77-94. 330. Steinberger, R., et al., Oxygen accumulation on metal surfaces investigated by XPS, AES and LEIS, an issue for sputter depth profiling under UHV conditions. Applied Surface Science, 2017. 411: p. 189-196. 331. Jenko, M., et al., Surface chemistry and microstructure of metallic biomaterials for hip and knee endoprostheses. Applied Surface Science, 2018. 427: p. 584-593. 332. Ray, S. and A.G. Shard, Quantitative analysis of adsorbed proteins by X-ray photoelectron spectroscopy. Anal Chem, 2011. 83(22): p. 8659-66. 333. Vanea, E. and V. Simon, XPS study of protein adsorption onto nanocrystalline aluminosilicate microparticles. Applied Surface Science, 2011. 257(6): p. 2346-2352. 334. Sera Laboratories International Ltd., Certificate of Analysis, in Product: Foetal Bovine Serum European Grade. 2017: Colombia. 335. Van Doveren, H. and J.A.T.H. Verhoeven, XPS spectra of Ca, Sr, Ba and their oxides. Journal of Electron Spectroscopy and Related Phenomena, 1980. 21(3): p. 265-273. 336. Hanawa, T. and M. Ota, Calcium phosphate naturally formed on titanium in electrolyte solution. Biomaterials, 1991. 12(8): p. 767-74. 337. Demri, B. and D. Muster, XPS study of some calcium compounds. Journal of Materials Processing Technology, 1995. 55(3): p. 311-314. 338. Watson, I.M., J.A. Connor, and R. Whyman, Non-crystalline chromium, molybdenum and tungsten phosphate films prepared by metal organic chemical vapour deposition. Thin Solid Films, 1991. 201(2): p. 337-349. 339. Moffat, T.P., R.M. Latanision, and R.R. Ruf, An X-ray photoelectron spectroscopy study of chromium-metalloid alloys—III. Electrochimica Acta, 1995. 40(11): p. 1723-1734. 340. Di Laura, A., et al., The Chemical Form of Metal Species Released from Corroded Taper Junctions of Hip Implants: Synchrotron Analysis of Patient Tissue. Scientific Reports, 2017. 7(1): p. 10952. 341. Payne, B.P., M.C. Biesinger, and N.S. McIntyre, Use of oxygen/nickel ratios in the XPS characterisation of oxide phases on nickel metal and nickel alloy surfaces. Journal of Electron Spectroscopy and Related Phenomena, 2012. 185(5): p. 159-166. 342. Guo, L.Q., et al., Effect of hydrogen on semiconductive properties of passive film on ferrite and austenite phases in a duplex stainless steel. Scientific Reports, 2017. 7(1): p. 3317. 343. Honna, M., et al., Effect of friction stroke length on damage and restoration of the passive film of cobalt chromium alloy. Kitasato Med J, 2017. 47: p. 10-16. 344. Donnet, C., et al., Super-low friction of MoS2 coatings in various environments. Tribology International, 1996. 29(2): p. 123-128. 345. Farr, J.P.G., Molybdenum disulphide in lubrication. A review. Wear, 1975. 35(1): p. 1-22. 346. Catelas, I., M.A. Wimmer, and S. Utzschneider, Polyethylene and metal wear particles: characteristics and biological effects. Seminars in Immunopathology, 2011. 33(3): p. 257-271. 347. Ito, H., et al., Reduction of polyethylene wear by concave dimples on the frictional surface in artificial hip joints. J Arthroplasty, 2000. 15(3): p. 332-8. 348. Lee, R., et al., Scratch and wear performance of prosthetic femoral head components against crosslinked UHMWPE sockets. Wear, 2009. 267(11): p. 1915-1921. 349. Peaker, A.J.S. and J. Czernuszka, The Effect of Electric Field on the Formation of Hydroxyapatite Coatings. Vol. 287. 1996. 174–183. 350. Neville, A., T. Hodgkiess, and A.P. Morizot, Surface scales in sea water systems: Effects of their formation on corrosion behaviour of engineering steels. British Corrosion Journal, 1997. 32(4): p. 277-282. 351. Zhang, X. and M. Cresswell, Chapter 6 - Calcium Phosphate Materials for Controlled Release Systems, in Inorganic Controlled Release Technology, X. Zhang and M. Cresswell, Editors. 2016, Butterworth-Heinemann: Boston. p. 161-187. 352. Shin, J.W., G.R. Stafford, and K.R. Hebert, Stress in aluminum induced by hydrogen absorption during cathodic polarization. Corrosion Science, 2015. 98: p. 366-371. 353. Stankovich, M.T. and A.J. Bard, The electrochemistry of proteins and related substances part III. Bovine serum albumin. Journal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1978. 86(1): p. 189-199. 354. Kocijan, A., et al., Electrochemical Study of Co-Based Alloys in Simulated Physiological Solution. Journal of Applied Electrochemistry, 2004. 34(5): p. 517-524. 355. Moreto, J., et al., Effect of Temperature, Electrolyte Composition and Immersion Time on the Electrochemical Corrosion Behavior of CoCrMo Implant Alloy Exposed to Physiological Serum and Hank's Solution. Materials Research, 2018. 21. 356. Perret, J., et al., EBSD, SEM and FIB characterisation of subsurface deformation during tribocorrosion of stainless steel in sulphuric acid. Wear, 2010. 269(5): p. 383-393. 357. Bidiville, A., et al., Effect of surface chemistry on the mechanical response of metals in sliding tribocorrosion systems. Wear, 2007. 263(1): p. 207-217. 358. Wang, Z., et al., Effect of proteins on the surface microstructure evolution of a CoCrMo alloy in bio-tribocorrosion processes. Colloids and Surfaces B: Biointerfaces, 2016. 145: p. 176-184. 359. Wimmer, M., et al., Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2006. 220(2): p. 219-227. 360. Sun, D., J.A. Wharton, and R.J.K. Wood, Micro-abrasion mechanisms of cast CoCrMo in simulated body fluids. Wear, 2009. 267(11): p. 1845-1855. 361. Valero Vidal, C. and A. Igual Muñoz, Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluids. Corrosion Science, 2008. 50(7): p. 1954-1961. 362. Luo, L., et al., Effect of cobalt and chromium ions on MMP-1, TIMP-1, and TNF-α gene expression in human U937 macrophages: A role for tyrosine kinases. Biomaterials, 2005. 26(28): p. 5587-5593. 363. Dufils, J., et al., Influence of molybdate ion and pH on the fretting corrosion of a CoCrMo – Titanium alloy couple. Biotribology, 2017. 11: p. 20-28. 364. Talha, M., et al., Role of protein adsorption in the bio corrosion of metallic implants – A review. Colloids and Surfaces B: Biointerfaces, 2019. 176: p. 494-506. 365. Landolt, D., S. Mischler, and M. Stemp, Electrochemical methods in tribocorrosion: a critical appraisal. Electrochimica Acta, 2001. 46(24): p. 3913-3929. 366. Barril, S., S. Mischler, and D. Landolt, Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution. Wear, 2005. 259(1): p. 282-291. 367. Favero, M., P. Stadelmann, and S. Mischler, Effect of the applied potential of the near surface microstructure of a 316L steel submitted to tribocorrosion in sulfuric acid. Journal of Physics D: Applied Physics, 2006. 39: p. 3175-3183. 368. Guadalupe Maldonado, S., et al., Mechanical and chemical mechanisms in the tribocorrosion of a Stellite type alloy. Wear, 2013. 308(1): p. 213-221. 369. Neville, A., et al., Incorporating corrosion measurement in hip wear simulators: An added complication or a necessity? 2016. 230(5): p. 406-420. 370. Yan, Y., et al., Real-time corrosion measurements to assess biotribocorrosion mechanisms with a hip simulator. Tribology International, 2013. 63: p. 115-122."],"dcterms:accessrights":["public"],"dc:title":["Tribocorrosion and tribochemistry of cobalt-chromium alloy used for total hip replacement"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000284624798"]},"updated_at":"2026-11-18T22:43:31Z"}