{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:30820"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:30820","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Computational models for the pre-operative planning of spinal surgeries","abstract":"Spinal surgeries are common to treat different types of diseases and injuries as trauma, tumours, deformity and degenerative diseases. Conventional open spine surgery has several reported limitations and there is a trend towards minimally invasive techniques due to lower complication rates and morbidity. Percutaneous pedicle screw fixation and vertebral augmentation are two widespread minimally invasive techniques that are often chosen to treat vertebral fractures. The pre-planning of spinal surgeries is based on anatomical measurements taken on clinical images and on the experience of surgeons. Post-operative complications may arise impacting the quality of life of patients. Computational models can provide important patient-specific information about the biomechanics and the geometry of the spine. Finite element (FE) models have the potential to predict the biomechanical outcomes of surgeries and are often proposed as possible tools for planning pedicle screw fixation. However, before their application, these models have to be verified and the sensitivity of metrics used to assess metal and bone failure have to be assessed with respect to the screw size and geometry. This was the aim of the first study. Patient-specific Computed Tomography (CT)-based FE models of the human vertebra with two pedicle screws were verified for both realistic and simplified geometry of screws. The diameter of the screw played a major role on the mechanics of the screw-vertebral structure with respect to the length. Simplified screws could accurately estimate the deflection and the strain of the implanted vertebrae, but resulted in a systematic underestimation of the peak stress in the screws. FE models can be used to optimize surgery-related parameters, but take a long time to compute and are thus insufficient to fulfil the demands of most clinical settings. Reduced Order Models (ROMs) are useful tools to improve the efficiency of FE models, and, in this thesis, were applied to FE models of the implanted vertebra to optimise screws’ size and orientation showing accurate prediction of the deflection and the stress of the screws. A third study included the development of a CT-scan based procedure to estimate the pre-fracture 3D shape of a L1 vertebra that could be used by surgeons to restore the pre-fracture biomechanics. The methodology was validated on a dataset with 40 patients and showed excellent reconstruction accuracy. In conclusion, FE models of the implanted vertebra were integrated with ROMs to build a computational pipeline for the optimisation of dimensions and positioning of pedicle screws. Also, the geometric pre-fracture shape of a L1 vertebra was reconstructed. These approaches can be used to provide more quantitative biomechanical and geometric information to surgeons for planning the treatment of vertebral fractures.","abstract_html":"Spinal surgeries are common to treat different types of diseases and injuries as trauma, tumours, deformity and degenerative diseases. Conventional open spine surgery has several reported limitations and there is a trend towards minimally invasive techniques due to lower complication rates and morbidity. Percutaneous pedicle screw fixation and vertebral augmentation are two widespread minimally invasive techniques that are often chosen to treat vertebral fractures. The pre-planning of spinal surgeries is based on anatomical measurements taken on clinical images and on the experience of surgeons. Post-operative complications may arise impacting the quality of life of patients. Computational models can provide important patient-specific information about the biomechanics and the geometry of the spine. Finite element (FE) models have the potential to predict the biomechanical outcomes of surgeries and are often proposed as possible tools for planning pedicle screw fixation. However, before their application, these models have to be verified and the sensitivity of metrics used to assess metal and bone failure have to be assessed with respect to the screw size and geometry. This was the aim of the first study. Patient-specific Computed Tomography (CT)-based FE models of the human vertebra with two pedicle screws were verified for both realistic and simplified geometry of screws. The diameter of the screw played a major role on the mechanics of the screw-vertebral structure with respect to the length. Simplified screws could accurately estimate the deflection and the strain of the implanted vertebrae, but resulted in a systematic underestimation of the peak stress in the screws. FE models can be used to optimize surgery-related parameters, but take a long time to compute and are thus insufficient to fulfil the demands of most clinical settings. Reduced Order Models (ROMs) are useful tools to improve the efficiency of FE models, and, in this thesis, were applied to FE models of the implanted vertebra to optimise screws’ size and orientation showing accurate prediction of the deflection and the stress of the screws. A third study included the development of a CT-scan based procedure to estimate the pre-fracture 3D shape of a L1 vertebra that could be used by surgeons to restore the pre-fracture biomechanics. The methodology was validated on a dataset with 40 patients and showed excellent reconstruction accuracy. In conclusion, FE models of the implanted vertebra were integrated with ROMs to build a computational pipeline for the optimisation of dimensions and positioning of pedicle screws. Also, the geometric pre-fracture shape of a L1 vertebra was reconstructed. These approaches can be used to provide more quantitative biomechanical and geometric information to surgeons for planning the treatment of vertebral fractures.","abstract_has_math":false,"creators":["Sensale, Marco"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Dall'Ara, Enrico"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-12","date_published":"2021-12","updated_at":"2026-11-18T23:18:18Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.855707"],"render_values":[{"text":"uk.bl.ethos.855707","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["766012","EP/K038771X/1"],"render_values":[{"text":"766012","href":null,"code":true},{"text":"EP/K038771X/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000261331503"],"render_values":[{"text":"0000-0002-6133-1503","href":"https://orcid.org/0000-0002-6133-1503","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/30820/1/Main_thesis_All_def_Rev_def_Sensale.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A30820","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dall'Ara, Enrico"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EU H2020 Spinner project","EPSRC MultiSim project"]},{"key":"dc:creator","label":"Author","values":["Sensale, Marco"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000261331503"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-12"]},{"key":"dc:date.issued","label":"Date","values":["2021-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medicine (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/30820/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Abbeele, M. V. den, Valiadis, J.-M., Lima, L. V. P. C., Khalifé, P., Rouch, P., and Skalli, W. (2018). Contribution to FE modeling for intraoperative pedicle screw strength prediction. Comput. Methods Biomech. Biomed. Engin. 21, 13–21. doi:10.1080/10255842.2017.1414200. Aebi, M. (2007). AOSpine Manual. AOSpine International. Assessing Credibility of Computational Modeling through Verification & Validation: Application to Medical Devices - ASME Available at: https://www.asme.org/codes-standards/find-codes-standards/v-v-40-assessing-credibility-computational-modeling-verification-validation-application-medical-devices [Accessed October 26, 2020]. BEN SALEM, M., and Tomaso, L. (2018). Automatic selection for general surrogate models. Struct. Multidiscip. Optim. Available at: https://hal.archives-ouvertes.fr/hal-01685848 [Accessed July 9, 2021]. Bianco, R.-J., Arnoux, P.-J., Mac-Thiong, J.-M., and Aubin, C.-E. (2019). Thoracic pedicle screw fixation under axial and perpendicular loadings: A comprehensive numerical analysis. Clin. Biomech. 68, 190–196. doi:10.1016/j.clinbiomech.2019.06.010. Bianco, R.-J., Arnoux, P.-J., Wagnac, E., Mac-Thiong, J.-M., and Aubin, C.-É. (2017). Minimizing Pedicle Screw Pullout Risks: A Detailed Biomechanical Analysis of Screw Design and Placement. Clin. Spine Surg. 30, E226–E232. doi:10.1097/BSD.0000000000000151. Biancolini, M. E. (2017). “RBF Mesh Morphing,” in Fast Radial Basis Functions for Engineering Applications, ed. M. E. Biancolini (Cham: Springer International Publishing), 93–117. doi:10.1007/978-3-319-75011-8_6. Biancolini, M. E., Capellini, K., Costa, E., Groth, C., and Celi, S. (2020). Fast interactive CFD evaluation of hemodynamics assisted by RBF mesh morphing and reduced order models: the case of aTAA modelling. Int. J. Interact. Des. Manuf. IJIDeM 14, 1227–1238. doi:10.1007/s12008-020-00694-5. Biswas, J. K., Sahu, T. P., Rana, M., Roy, S., Karmakar, S. K., Majumder, S., et al. (2019). Design factors of lumbar pedicle screws under bending load: A finite element analysis. Biocybern. Biomed. Eng. 39, 52–62. doi:10.1016/j.bbe.2018.10.003. Brunton, A., Salazar, A., Bolkart, T., and Wuhrer, S. (2016). “STATISTICAL SHAPE SPACES FOR 3D DATA: A REVIEW,” in Handbook of Pattern Recognition and Computer Vision (WORLD SCIENTIFIC), 217–238. doi:10.1142/9789814656535_0012. Caiazzo, A., Guibert, R., and Vignon-Clementel, I. E. (2016). A reduced-order modeling for efficient design study of artificial valve in enlarged ventricular outflow tracts. Comput. Methods Biomech. Biomed. Engin. 19, 1314–1318. doi:10.1080/10255842.2015.1133811. Calka, M., Perrier, P., Ohayon, J., Grivot-Boichon, C., Rochette, M., and Payan, Y. (2021). Machine-Learning based model order reduction of a biomechanical model of the human tongue. Comput. Methods Programs Biomed. 198, 105786. doi:10.1016/j.cmpb.2020.105786. Campbell, J. Q., and Petrella, A. J. (2015). An Automated Method for Landmark Identification and Finite-Element Modeling of the Lumbar Spine. IEEE Trans. Biomed. Eng. 62, 2709–2716. doi:10.1109/TBME.2015.2444811. Campbell, J. Q., and Petrella, A. J. (2016). Automated finite element modeling of the lumbar spine: Using a statistical shape model to generate a virtual population of models. J. Biomech. 49, 2593–2599. doi:10.1016/j.jbiomech.2016.05.013. Castro-Mateos, I., Pozo, J., Lazáry, A., and Frangi, A. (2016). Automatic construction of patient-specific finite-element mesh of the spine from IVDs and vertebra segmentations. doi:10.1117/12.2217343. Chen, S.-I., Lin, R.-M., and Chang, C.-H. (2003). Biomechanical investigation of pedicle screw–vertebrae complex: a finite element approach using bonded and contact interface conditions. Med. Eng. Phys. 25, 275–282. doi:10.1016/S1350-4533(02)00219-9. Chevalier, Y., Matsuura, M., Krüger, S., Fleege, C., Rickert, M., Rauschmann, M., et al. (2018). Micro-CT and micro-FE analysis of pedicle screw fixation under different loading conditions. J. Biomech. 70, 204–211. doi:10.1016/j.jbiomech.2017.12.023. Cho, W., Cho, S. K., and Wu, C. (2010). The biomechanics of pedicle screw-based instrumentation. J. Bone Joint Surg. Br. 92, 1061–1065. doi:10.1302/0301-620X.92B8.24237. Clogenson, M., Duff, J. M., Luethi, M., Levivier, M., Meuli, R., Baur, C., et al. (2015). A statistical shape model of the human second cervical vertebra. Int. J. Comput. Assist. Radiol. Surg. 10, 1097–1107. doi:10.1007/s11548-014-1121-x. Commandeur, F., Velut, J., and Acosta, O. (2011). A VTK Algorithm for the Computation of the Hausdorff Distance. VTK J., 839. Cootes, T. F., Taylor, C. J., Cooper, D. H., and Graham, J. (1995). Active Shape Models-Their Training and Application. Comput. Vis. Image Underst. 61, 38–59. doi:10.1006/cviu.1995.1004. Costa, M. C., Eltes, P., Lazary, A., Varga, P. P., Viceconti, M., and Dall’Ara, E. (2019). Biomechanical assessment of vertebrae with lytic metastases with subject-specific finite element models. J. Mech. Behav. Biomed. Mater. 98, 268–290. doi:10.1016/j.jmbbm.2019.06.027. Dall’Ara, E., Pahr, D., Varga, P., Kainberger, F., and Zysset, P. (2012). QCT-based finite element models predict human vertebral strength in vitro significantly better than simulated DEXA. Osteoporos. Int. J. Establ. Result Coop. Eur. Found. Osteoporos. Natl. Osteoporos. Found. USA 23, 563–572. doi:10.1007/s00198-011-1568-3. Dall’Ara, E., Peña-Fernández, M., Palanca, M., Giorgi, M., Cristofolini, L., and Tozzi, G. (2017). Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels. Front. Mater. 4. doi:10.3389/fmats.2017.00031. de Bruijne, M., Lund, M. T., Tankó, L. B., Pettersen, P. C., and Nielsen, M. (2007). Quantitative vertebral morphometry using neighbor-conditional shape models. Med. Image Anal. 11, 503–512. doi:10.1016/j.media.2007.07.004. Elmasry, S., Asfour, S., and Travascio, F. (2017). Effectiveness of pedicle screw inclusion at the fracture level in short-segment fixation constructs for the treatment of thoracolumbar burst fractures: a computational biomechanics analysis. Comput. Methods Biomech. Biomed. Engin. 20, 1412–1420. doi:10.1080/10255842.2017.1366995. Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., et al. (2012). 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn. Reson. Imaging 30, 1323–1341. doi:10.1016/j.mri.2012.05.001. Fields, A. J., Eswaran, S. K., Jekir, M. G., and Keaveny, T. M. (2009). Role of Trabecular Microarchitecture in Whole-Vertebral Body Biomechanical Behavior. J. Bone Miner. Res. 24, 1523–1530. doi:10.1359/jbmr.090317. Ganapathi, A., McCarron, J. A., Chen, X., and Iannotti, J. P. (2011). Predicting normal glenoid version from the pathologic scapula: a comparison of 4 methods in 2- and 3-dimensional models. J. Shoulder Elbow Surg. 20, 234–244. doi:10.1016/j.jse.2010.05.024. Gelaude, F., Clijmans, T., Broos, P. L., Lauwers, B., and Vander Sloten, J. (2007). Computer-aided planning of reconstructive surgery of the innominate bone: Automated correction proposals. Comput. Aided Surg. 12, 286–294. doi:10.3109/10929080701684762. Genant, H. K., Wu, C. Y., van Kuijk, C., and Nevitt, M. C. (1993). Vertebral fracture assessment using a semiquantitative technique. J. Bone Miner. Res. Off. J. Am. Soc. Bone Miner. Res. 8, 1137–1148. doi:10.1002/jbmr.5650080915. Gertzbein, S. D., and Robbins, S. E. (1990). Accuracy of Pedicular Screw Placement In Vivo. Spine 15, 11–14. Global Pedicle Screw System Market by Product, Surgery Type, Indication, Application, Region, Industry Analysis, Size, Share, Growth, Trends, and Forecast 2018 to 2025 - Fior Markets Available at: https://www.fiormarkets.com/report/global-pedicle-screw-system-market-by-product-polyaxial-375967.html [Accessed October 26, 2020]. Grassi, L., Hraiech, N., Schileo, E., Ansaloni, M., Rochette, M., and Viceconti, M. (2011). Evaluation of the generality and accuracy of a new mesh morphing procedure for the human femur. Med. Eng. Phys. 33, 112–120. doi:10.1016/j.medengphy.2010.09.014. Heimann, T., and Meinzer, H.-P. (2009). Statistical shape models for 3D medical image segmentation: a review. Med. Image Anal. 13, 543–563. doi:10.1016/j.media.2009.05.004. Hingsammer, A. M., Vlachopoulos, L., Meyer, D. C., and Fürnstahl, P. (2015). Three-dimensional corrective osteotomies of mal-united clavicles—is the contralateral anatomy a reliable template for reconstruction? Clin. Anat. 28, 865–871. doi:10.1002/ca.22572. Hoang, K. C., Khoo, B. C., Liu, G. R., Nguyen, N. C., and Patera, A. T. (2013). Rapid identification of material properties of the interface tissue in dental implant systems using reduced basis method. Inverse Probl. Sci. Eng. 21, 1310–1334. doi:10.1080/17415977.2012.757315. Ignasiak, D., Dendorfer, S., and Ferguson, S. J. (2016). Thoracolumbar spine model with articulated ribcage for the prediction of dynamic spinal loading. J. Biomech. 49, 959–966. doi:10.1016/j.jbiomech.2015.10.010. Inzana, J. A., Varga, P., and Windolf, M. (2016). Implicit modeling of screw threads for efficient finite element analysis of complex bone-implant systems. J. Biomech. 49, 1836–1844. doi:10.1016/j.jbiomech.2016.04.021. Kirschke, J. S., Löffler, M., and Sekuboyina, A. (2020). Verse 2020. Available at: https://osf.io/t98fz/ [Accessed March 11, 2021]. Kopperdahl, D. L., Morgan, E. F., and Keaveny, T. M. (2002). Quantitative computed tomography estimates of the mechanical properties of human vertebral trabecular bone. J. Orthop. Res. 20, 801–805. doi:10.1016/S0736-0266(01)00185-1. Krol, Z., Skadlubowicz, P., Hefti, F., and Krieg, A. H. (2013). Virtual reconstruction of pelvic tumor defects based on a gender-specific statistical shape model. Comput. Aided Surg. Off. J. Int. Soc. Comput. Aided Surg. 18, 142–153. doi:10.3109/10929088.2013.777973. Kumar, A., Aujla, R., and Lee, C. (2015). The management of thoracolumbar burst fractures: a prospective study between conservative management, traditional open spinal surgery and minimally interventional spinal surgery. SpringerPlus 4, 204. doi:10.1186/s40064-015-0960-4. Lauzeral, N., Borzacchiello, D., Kugler, M., George, D., Rémond, Y., Hostettler, A., et al. (2019). A model order reduction approach to create patient-specific mechanical models of human liver in computational medicine applications. Comput. Methods Programs Biomed. 170, 95–106. doi:10.1016/j.cmpb.2019.01.003. Li, C., Zhou, Y., Wang, H., Liu, J., and Xiang, L. (2014). Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis. PLoS ONE 9. doi:10.1371/journal.pone.0099156. Liebl, H., Schinz, D., Sekuboyina, A., Malagutti, L., Löffler, M. T., Bayat, A., et al. (2021). A Computed Tomography Vertebral Segmentation Dataset with Anatomical Variations and Multi-Vendor Scanner Data. ArXiv210306360 Cs Eess. Available at: http://arxiv.org/abs/2103.06360 [Accessed March 21, 2021]. Liu, H., Wang, H., Liu, J., Li, C., Zhou, Y., and Xiang, L. (2019). Biomechanical comparison of posterior intermediate screw fixation techniques with hybrid monoaxial and polyaxial pedicle screws in the treatment of thoracolumbar burst fracture: a finite element study. J. Orthop. Surg. 14, 122. doi:10.1186/s13018-019-1149-2. Löffler, M. T., Sekuboyina, A., Jacob, A., Grau, A.-L., Scharr, A., El Husseini, M., et al. (2020a). A Vertebral Segmentation Dataset with Fracture Grading. Radiol. Artif. Intell. 2, e190138. doi:10.1148/ryai.2020190138. Löffler, M. T., Sekuboyina, A., Jacob, A., Grau, A.-L., Scharr, A., El Husseini, M., et al. (2020b). A Vertebral Segmentation Dataset with Fracture Grading. Radiol. Artif. Intell. 2, e190138. doi:10.1148/ryai.2020190138. Luboz, V., Bailet, M., Boichon Grivot, C., Rochette, M., Diot, B., Bucki, M., et al. (2018). Personalized modeling for real-time pressure ulcer prevention in sitting posture. J. Tissue Viability 27, 54–58. doi:10.1016/j.jtv.2017.06.002. Luthi, M., Gerig, T., Jud, C., and Vetter, T. (2018). Gaussian Process Morphable Models. IEEE Trans. Pattern Anal. Mach. Intell. 40, 1860–1873. doi:10.1109/TPAMI.2017.2739743. Magerl, F., Aebi, M., Gertzbein, S. D., Harms, J., and Nazarian, S. (1994). A comprehensive classification of thoracic and lumbar injuries. Eur. Spine J. 3, 184–201. doi:10.1007/BF02221591. Mahar, A., Kim, C., Wedemeyer, M., Mitsunaga, L., Odell, T., Johnson, B., et al. (2007). Short-Segment Fixation of Lumbar Burst Fractures Using Pedicle Fixation at the Level of the Fracture. Spine 32, 1503–1507. doi:10.1097/BRS.0b013e318067dd24. Manzoni, A., Quarteroni, A., and Rozza, G. (2012). Model reduction techniques for fast blood flow simulation in parametrized geometries. Int. J. Numer. Methods Biomed. Eng. 28, 604–625. doi:10.1002/cnm.1465. Matsukawa, K., Yato, Y., Hynes, R. A., Imabayashi, H., Hosogane, N., Asazuma, T., et al. (2017). Cortical Bone Trajectory for Thoracic Pedicle Screws: A Technical Note. Clin. Spine Surg. 30, E497. doi:10.1097/BSD.0000000000000130. Matsukawa, K., Yato, Y., and Imabayashi, H. (2020). Impact of Screw Diameter and Length on Pedicle Screw Fixation Strength in Osteoporotic Vertebrae: A Finite Element Analysis. Asian Spine J. doi:10.31616/asj.2020.0353. Matsukawa, K., Yato, Y., Imabayashi, H., Hosogane, N., Abe, Y., Asazuma, T., et al. (2016). Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation? Acta Neurochir. (Wien) 158, 465–471. doi:10.1007/s00701-016-2705-8. Matsukawa, K., Yato, Y., Imabayashi, H., Hosogane, N., Asazuma, T., and Nemoto, K. (2015). Biomechanical evaluation of the fixation strength of lumbar pedicle screws using cortical bone trajectory: a finite element study. J. Neurosurg. Spine 23, 471–478. doi:10.3171/2015.1.SPINE141103. Mobbs, R. J., Sivabalan, P., and Li, J. (2011). Technique, challenges and indications for percutaneous pedicle screw fixation. J. Clin. Neurosci. 18, 741–749. doi:10.1016/j.jocn.2010.09.019. Molinari, L., and Falcinelli, C. (2021). On the human vertebra computational modeling: a literature review. Meccanica. doi:10.1007/s11012-021-01452-x. Molinari, L., Falcinelli, C., Gizzi, A., and Di Martino, A. (2021). Effect of pedicle screw angles on the fracture risk of the human vertebra: A patient-specific computational model. J. Mech. Behav. Biomed. Mater. 116, 104359. doi:10.1016/j.jmbbm.2021.104359. Monier-Faugere, M.-C., Chris Langub, M., and Malluche, H. H. (1998). “Chapter 8 - Bone Biopsies: A Modern Approach,” in Metabolic Bone Disease and Clinically Related Disorders (Third Edition), eds. L. V. Avioli and S. M. Krane (San Diego: Academic Press), 237–280e. doi:10.1016/B978-012068700-8/50009-8. Morgan, E. F., Bayraktar, H. H., and Keaveny, T. M. (2003). Trabecular bone modulus–density relationships depend on anatomic site. J. Biomech. 36, 897–904. doi:10.1016/S0021-9290(03)00071-X. Musuamba, F. T., Skottheim Rusten, I., Lesage, R., Russo, G., Bursi, R., Emili, L., et al. (2021). Scientific and regulatory evaluation of mechanistic in silico drug and disease models in drug development: building model credibility. CPT Pharmacomet. Syst. Pharmacol. Available at: https://eprints.whiterose.ac.uk/175265/ [Accessed December 14, 2021]. Nakahashi, M., Uei, H., Tokuhashi, Y., Maseda, M., Sawada, H., Soma, H., et al. (2019). Vertebral fracture in elderly female patients after posterior fusion with pedicle screw fixation for degenerative lumbar pathology: a retrospective cohort study. BMC Musculoskelet. Disord. 20, 259. doi:10.1186/s12891-019-2534-z. Newcomb, A. G. U. S., Baek, S., Kelly, B. P., and Crawford, N. R. (2017). Effect of screw position on load transfer in lumbar pedicle screws: A non-idealized finite element analysis. Comput. Methods Biomech. Biomed. Engin. 20, 182–192. doi:10.1080/10255842.2016.1209187. Niinomi, M., and Boehlert, C. J. (2015). “Titanium Alloys for Biomedical Applications,” in Advances in Metallic Biomaterials: Tissues, Materials and Biological Reactions Springer Series in Biomaterials Science and Engineering., eds. M. Niinomi, T. Narushima, and M. Nakai (Berlin, Heidelberg: Springer), 179–213. doi:10.1007/978-3-662-46836-4_8. Niroomandi, S., Alfaro, I., Cueto, E., and Chinesta, F. (2012). Accounting for large deformations in real-time simulations of soft tissues based on reduced-order models. Comput. Methods Programs Biomed. 105, 1–12. doi:10.1016/j.cmpb.2010.06.012. Niroomandi, S., Perrier, A., Bucki, M., and Payan, Y. (2020). “Chapter 5 - Real-time computer modeling in prevention of foot pressure ulcer using patient-specific finite element model and model order reduction techniques,” in Innovations and Emerging Technologies in Wound Care, ed. A. Gefen (Academic Press), 87–102. doi:10.1016/B978-0-12-815028-3.00005-5. Ovesy, M., Voumard, B., and Zysset, P. (2018). A nonlinear homogenized finite element analysis of the primary stability of the bone-implant interface. Biomech. Model. Mechanobiol. 17, 1471–1480. doi:10.1007/s10237-018-1038-3. Oxland, T. R., Lin, R.-M., and Panjabi, M. M. (1992). Three-Dimensional mechanical properties of the thoracolumbar junction. J. Orthop. Res. 10, 573–580. doi:https://doi.org/10.1002/jor.1100100412. Pahr, D. H., Schwiedrzik, J., Dall’Ara, E., and Zysset, P. K. (2014). Clinical versus pre-clinical FE models for vertebral body strength predictions. J. Mech. Behav. Biomed. Mater. 33, 76–83. doi:10.1016/j.jmbbm.2012.11.018. Palanca, M., Oliviero, S., and Dall’Ara, E. (2022). MicroFE models of porcine vertebrae with induced bone focal lesions: Validation of predicted displacements with digital volume correlation. J. Mech. Behav. Biomed. Mater. 125, 104872. doi:10.1016/j.jmbbm.2021.104872. Pascoletti, G., Aldieri, A., Terzini, M., Bhattacharya, P., Calì, M., and Zanetti, E. M. (2021). Stochastic PCA-Based Bone Models from Inverse Transform Sampling: Proof of Concept for Mandibles and Proximal Femurs. Appl. Sci. 11, 5204. doi:10.3390/app11115204. Perera, A., Qureshi, A., and Brecknell, J. E. (2015). Mono-segment fixation of thoracolumbar burst fractures. Br. J. Neurosurg. 29, 358–361. doi:10.3109/02688697.2014.987216. Perrier, A., Bucki, M., Luboz, V., Vuillerme, N., and Payan, Y. (2015). 3D musculoskeletal finite element analysis of the foot kinematics under muscle activation with and without ankle arthrodesis. Comput. Methods Biomech. Biomed. Engin. 18, 2022–2023. doi:10.1080/10255842.2015.1069605. Pesce, V., Piazzolla, A., Moretti, L., Carlucci, S., Parato, C., Maxy, P., et al. (2013). The vertebral biomechanic previous and after kyphoplasty. Aging Clin. Exp. Res. 25, 71–74. doi:10.1007/s40520-013-0073-2. Plessers, K., Berghe, P. V., Dijck, C. V., Wirix-Speetjens, R., Debeer, P., Jonkers, I., et al. (2018). Virtual reconstruction of glenoid bone defects using a statistical shape model. J. Shoulder Elbow Surg. 27, 160–166. doi:10.1016/j.jse.2017.07.026. Ponnusamy, K. E., Iyer, S., Gupta, G., and Khanna, A. J. (2011). Instrumentation of the osteoporotic spine: biomechanical and clinical considerations. Spine J. 11, 54–63. doi:10.1016/j.spinee.2010.09.024. Prud’homme, M., Barrios, C., Rouch, P., Charles, Y. P., Steib, J.-P., and Skalli, W. (2015). Clinical Outcomes and Complications After Pedicle-anchored Dynamic or Hybrid Lumbar Spine Stabilization: A Systematic Literature Review. J. Spinal Disord. Tech. 28, E439–E448. doi:10.1097/BSD.0000000000000092. Rajaee, S. S., Bae, H. W., Kanim, L. E. A., and Delamarter, R. B. (2012). Spinal fusion in the United States: analysis of trends from 1998 to 2008. Spine 37, 67–76. doi:10.1097/BRS.0b013e31820cccfb. Rijsbergen, M. van, van Rietbergen, B., Barthelemy, V., Eltes, P., Lazáry, Á., Lacroix, D., et al. (2018). Comparison of patient-specific computational models vs. clinical follow-up, for adjacent segment disc degeneration and bone remodelling after spinal fusion. PloS One 13, e0200899. doi:10.1371/journal.pone.0200899. Rohlmann, A., Bergmann, G., and Graichen, F. (1997). Loads on an internal spinal fixation device during walking. J. Biomech. 30, 41–47. doi:10.1016/S0021-9290(96)00103-0. Rohlmann, A., Graichen, F., Kayser, R., Bender, A., and Bergmann, G. (2008). Loads on a telemeterized vertebral body replacement measured in two patients. Spine 33, 1170–1179. doi:10.1097/BRS.0b013e3181722d52. Salhi, A., Burdin, V., Boutillon, A., Brochard, S., Mutsvangwa, T., and Borotikar, B. (2020). Statistical Shape Modeling Approach to Predict Missing Scapular Bone. Ann. Biomed. Eng. 48, 367–379. doi:10.1007/s10439-019-02354-6. Sanderson, P. L., Fraser, R. D., Hall, D. J., Cain, C. M. J., Osti, O. L., and Potter, G. R. (1999). Short segment fixation of thoracolumbar burst fractures without fusion. Eur. Spine J. 8, 495–500. doi:10.1007/s005860050212. Santoni, B. G., Hynes, R. A., McGilvray, K. C., Rodriguez-Canessa, G., Lyons, A. S., Henson, M. a. W., et al. (2009). Cortical bone trajectory for lumbar pedicle screws. Spine J. Off. J. North Am. Spine Soc. 9, 366–373. doi:10.1016/j.spinee.2008.07.008. Scalismo - Scalable Image and Shape Modelling | Scalismo Available at: https://scalismo.org/ [Accessed March 5, 2021]. Schileo, E., Dall’Ara, E., Taddei, F., Malandrino, A., Schotkamp, T., Baleani, M., et al. (2008). An accurate estimation of bone density improves the accuracy of subject-specific finite element models. J. Biomech. 41, 2483–2491. doi:10.1016/j.jbiomech.2008.05.017. Schousboe, J. T. (2016). Epidemiology of Vertebral Fractures. J. Clin. Densitom. 19, 8–22. doi:10.1016/j.jocd.2015.08.004. Sekuboyina, A., Bayat, A., Husseini, M. E., Löffler, M., Li, H., Tetteh, G., et al. (2020). VerSe: A Vertebrae Labelling and Segmentation Benchmark for Multi-detector CT Images. ArXiv200109193 Cs Eess. Available at: http://arxiv.org/abs/2001.09193 [Accessed March 5, 2021]. Sieger, D., Menzel, S., and Botsch, M. (2013). High Quality Mesh Morphing Using Triharmonic Radial Basis Functions. in Proceedings of the 21st International Meshing Roundtable, eds. X. Jiao and J.-C. Weill (Berlin, Heidelberg: Springer), 1–15. doi:10.1007/978-3-642-33573-0_1. Su, Y., Wang, X., Ren, D., Liu, Y., Liu, S., and Wang, P. (2018). A finite element study on posterior short segment fixation combined with unilateral fixation using pedicle screws for stable thoracolumbar fracture. Medicine (Baltimore) 97. doi:10.1097/MD.0000000000012046. Sun, X., Wang, H., Wang, W., Li, N., Hämäläinen, T., Ristaniemi, T., et al. (2021). A Statistical Model of Spine Shape and Material for Population-Oriented Biomechanical Simulation. IEEE Access, 1–1. doi:10.1109/ACCESS.2021.3129097. Taddei, F., Schileo, E., Helgason, B., Cristofolini, L., and Viceconti, M. (2007). The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements. Med. Eng. Phys. 29, 973–979. doi:10.1016/j.medengphy.2006.10.014. Ueno, M., Sakai, R., Tanaka, K., Inoue, G., Uchida, K., Imura, T., et al. (2015). Should we use cortical bone screws for cortical bone trajectory? J. Neurosurg. Spine 22, 416–421. doi:10.3171/2014.9.SPINE1484. unibas-gravis/scalismo (2021). Graphics and Vision Research Group University of Basel Available at: https://github.com/unibas-gravis/scalismo [Accessed March 5, 2021]. Van Meirhaeghe, J., Bastian, L., Boonen, S., Ranstam, J., Tillman, J. B., and Wardlaw, D. (2013). A Randomized Trial of Balloon Kyphoplasty and Nonsurgical Management for Treating Acute Vertebral Compression Fractures. Spine 38, 971–983. doi:10.1097/BRS.0b013e31828e8e22. Vanden Berghe, P., Demol, J., Gelaude, F., and Vander Sloten, J. (2017). Virtual anatomical reconstruction of large acetabular bone defects using a statistical shape model. Comput. Methods Biomech. Biomed. Engin. 20, 577–586. doi:10.1080/10255842.2016.1265110. Varghese, B., Short, D., Penmetsa, R., Goswami, T., and Hangartner, T. (2011). Computed-tomography-based finite-element models of long bones can accurately capture strain response to bending and torsion. J. Biomech. 44, 1374–1379. doi:10.1016/j.jbiomech.2010.12.028. Verma, K., Boniello, A., and Rihn, J. (2016). Emerging Techniques for Posterior Fixation of the Lumbar Spine. JAAOS - J. Am. Acad. Orthop. Surg. 24, 357–364. doi:10.5435/JAAOS-D-14-00378. Wang, E., Tran, K. L., D’heygere, E., and Prisman, E. (2021). Predicting the Premorbid Shape of a Diseased Mandible. The Laryngoscope 131, E781–E786. doi:https://doi.org/10.1002/lary.29009. Wang, H., Mo, Z., Han, J., Liu, J., Li, C., Zhou, Y., et al. (2018). Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures. Medicine (Baltimore) 97, e11244. doi:10.1097/MD.0000000000011244. Wang, J., Zhou, Y., Zhang, Z. F., Li, C. Q., Zheng, W. J., and Liu, J. (2013). Radiological study on disc degeneration of thoracolumbar burst fractures treated by percutaneous pedicle screw fixation. Eur. Spine J. 22, 489–494. doi:10.1007/s00586-012-2462-1. Wang, M. Y., Anderson, D. G., Poelstra, K. A., and Ludwig, S. C. (2008). MINIMALLY INVASIVE POSTERIOR FIXATION. Neurosurgery 63, A197–A203. doi:10.1227/01.NEU.0000320434.83458.10. Wang, W., Pei, B., Pei, Y., Shi, Z., Kong, C., Wu, X., et al. (2019). Biomechanical effects of posterior pedicle fixation techniques on the adjacent segment for the treatment of thoracolumbar burst fractures: a biomechanical analysis. Comput. Methods Biomech. Biomed. Engin. 22, 1083–1092. doi:10.1080/10255842.2019.1631286. Weese, J., Kaus, M., Lorenz, C., Lobregt, S., Truyen, R., and Pekar, V. (2001). Shape Constrained Deformable Models for 3D Medical Image Segmentation. in Information Processing in Medical Imaging Lecture Notes in Computer Science., eds. M. F. Insana and R. M. Leahy (Berlin, Heidelberg: Springer), 380–387. doi:10.1007/3-540-45729-1_38. Widmer, J., Fasser, M.-R., Croci, E., Spirig, J., Snedeker, J. G., and Farshad, M. (2020). Individualized prediction of pedicle screw fixation strength with a finite element model. Comput. Methods Biomech. Biomed. Engin. 23, 155–167. doi:10.1080/10255842.2019.1709173. Wirtz, D. C., Schiffers, N., Pandorf, T., Radermacher, K., Weichert, D., and Forst, R. (2000). Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. J. Biomech. 33, 1325–1330. doi:10.1016/S0021-9290(00)00069-5. Wood, K. B., Li, W., Lebl, D. S., and Ploumis, A. (2014). Management of thoracolumbar spine fractures. Spine J. 14, 145–164. doi:10.1016/j.spinee.2012.10.041. Wu, J., Cai, M., Li, J., Cao, L., Xu, L., Li, N., et al. (2019). Development and validation of a semi-automatic landmark extraction method for mesh morphing. Med. Eng. Phys. 70, 62–71. doi:10.1016/j.medengphy.2019.04.007. Xu, G., Fu, X., Du, C., Ma, J., Li, Z., Tian, P., et al. (2014). Biomechanical comparison of mono-segment transpedicular fixation with short-segment fixation for treatment of thoracolumbar fractures: A finite element analysis. Proc. Inst. Mech. Eng. [H] 228, 1005–1013. doi:10.1177/0954411914552308. Xu, Y., and Goodacre, R. (2018). On Splitting Training and Validation Set: A Comparative Study of Cross-Validation, Bootstrap and Systematic Sampling for Estimating the Generalization Performance of Supervised Learning. J. Anal. Test. 2, 249–262. doi:10.1007/s41664-018-0068-2. Yeung, S., Toor, A., Deib, G., Zhang, J., Besier, T., and Fernandez, J. (2020). Relationship between lower lumbar spine shape and patient bone metabolic activity as characterised by 18F NaF bio-markers. Comput. Biol. Med. 116, 103529. doi:10.1016/j.compbiomed.2019.103529. Zhang, J., Weir, V., Fajardo, L., Lin, J., Hsiung, H., and Ritenour, E. (2009). Dosimetric characterization of a cone-beam O-arm (TM) imaging system. J. X-Ray Sci. Technol. 17, 305–17. doi:10.3233/XST-2009-0231. Zindrick, M. R., Wiltse, L. L., Widell, E. H., Thomas, J. C., Holland, W. R., Field, B. T., et al. (1986). A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin. Orthop., 99–112. Zou, X. (2018). Simulation tools for biomechanical applications with PGD-based reduced order models. TDX Tesis Dr. En Xarxa. Available at: https://upcommons.upc.edu/handle/2117/116305 [Accessed November 24, 2021]. Zou, X., Conti, M., Díez, P., and Auricchio, F. (2018). A nonintrusive proper generalized decomposition scheme with application in biomechanics. Int. J. Numer. Methods Eng. 113, 230–251. doi:10.1002/nme.5610."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.855707"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["766012","EP/K038771X/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/30820/1/Main_thesis_All_def_Rev_def_Sensale.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Spinal surgeries are common to treat different types of diseases and injuries as trauma, tumours, deformity and degenerative diseases. Conventional open spine surgery has several reported limitations and there is a trend towards minimally invasive techniques due to lower complication rates and morbidity. Percutaneous pedicle screw fixation and vertebral augmentation are two widespread minimally invasive techniques that are often chosen to treat vertebral fractures. The pre-planning of spinal surgeries is based on anatomical measurements taken on clinical images and on the experience of surgeons. Post-operative complications may arise impacting the quality of life of patients. Computational models can provide important patient-specific information about the biomechanics and the geometry of the spine. Finite element (FE) models have the potential to predict the biomechanical outcomes of surgeries and are often proposed as possible tools for planning pedicle screw fixation. However, before their application, these models have to be verified and the sensitivity of metrics used to assess metal and bone failure have to be assessed with respect to the screw size and geometry. This was the aim of the first study. Patient-specific Computed Tomography (CT)-based FE models of the human vertebra with two pedicle screws were verified for both realistic and simplified geometry of screws. The diameter of the screw played a major role on the mechanics of the screw-vertebral structure with respect to the length. Simplified screws could accurately estimate the deflection and the strain of the implanted vertebrae, but resulted in a systematic underestimation of the peak stress in the screws. FE models can be used to optimize surgery-related parameters, but take a long time to compute and are thus insufficient to fulfil the demands of most clinical settings. Reduced Order Models (ROMs) are useful tools to improve the efficiency of FE models, and, in this thesis, were applied to FE models of the implanted vertebra to optimise screws’ size and orientation showing accurate prediction of the deflection and the stress of the screws. A third study included the development of a CT-scan based procedure to estimate the pre-fracture 3D shape of a L1 vertebra that could be used by surgeons to restore the pre-fracture biomechanics. The methodology was validated on a dataset with 40 patients and showed excellent reconstruction accuracy. In conclusion, FE models of the implanted vertebra were integrated with ROMs to build a computational pipeline for the optimisation of dimensions and positioning of pedicle screws. Also, the geometric pre-fracture shape of a L1 vertebra was reconstructed. These approaches can be used to provide more quantitative biomechanical and geometric information to surgeons for planning the treatment of vertebral fractures."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Computational models for the pre-operative planning of spinal surgeries"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dall'Ara, Enrico"],"dc:contributor.sponsor":["EU H2020 Spinner project","EPSRC MultiSim project"],"dc:creator":["Sensale, Marco"],"dc:date":["2021-12"],"dc:date.issued":["2021-12"],"dc:description.abstract":["Spinal surgeries are common to treat different types of diseases and injuries as trauma, tumours, deformity and degenerative diseases. Conventional open spine surgery has several reported limitations and there is a trend towards minimally invasive techniques due to lower complication rates and morbidity. Percutaneous pedicle screw fixation and vertebral augmentation are two widespread minimally invasive techniques that are often chosen to treat vertebral fractures. The pre-planning of spinal surgeries is based on anatomical measurements taken on clinical images and on the experience of surgeons. Post-operative complications may arise impacting the quality of life of patients. Computational models can provide important patient-specific information about the biomechanics and the geometry of the spine. Finite element (FE) models have the potential to predict the biomechanical outcomes of surgeries and are often proposed as possible tools for planning pedicle screw fixation. However, before their application, these models have to be verified and the sensitivity of metrics used to assess metal and bone failure have to be assessed with respect to the screw size and geometry. This was the aim of the first study. Patient-specific Computed Tomography (CT)-based FE models of the human vertebra with two pedicle screws were verified for both realistic and simplified geometry of screws. The diameter of the screw played a major role on the mechanics of the screw-vertebral structure with respect to the length. Simplified screws could accurately estimate the deflection and the strain of the implanted vertebrae, but resulted in a systematic underestimation of the peak stress in the screws. FE models can be used to optimize surgery-related parameters, but take a long time to compute and are thus insufficient to fulfil the demands of most clinical settings. Reduced Order Models (ROMs) are useful tools to improve the efficiency of FE models, and, in this thesis, were applied to FE models of the implanted vertebra to optimise screws’ size and orientation showing accurate prediction of the deflection and the stress of the screws. A third study included the development of a CT-scan based procedure to estimate the pre-fracture 3D shape of a L1 vertebra that could be used by surgeons to restore the pre-fracture biomechanics. The methodology was validated on a dataset with 40 patients and showed excellent reconstruction accuracy. In conclusion, FE models of the implanted vertebra were integrated with ROMs to build a computational pipeline for the optimisation of dimensions and positioning of pedicle screws. Also, the geometric pre-fracture shape of a L1 vertebra was reconstructed. These approaches can be used to provide more quantitative biomechanical and geometric information to surgeons for planning the treatment of vertebral fractures."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.855707"],"dc:identifier.grantnumber":["766012","EP/K038771X/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/30820/1/Main_thesis_All_def_Rev_def_Sensale.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Medicine (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/30820/"],"dc:relation.references":["Abbeele, M. V. den, Valiadis, J.-M., Lima, L. V. P. C., Khalifé, P., Rouch, P., and Skalli, W. (2018). Contribution to FE modeling for intraoperative pedicle screw strength prediction. Comput. Methods Biomech. Biomed. Engin. 21, 13–21. doi:10.1080/10255842.2017.1414200. Aebi, M. (2007). AOSpine Manual. AOSpine International. Assessing Credibility of Computational Modeling through Verification & Validation: Application to Medical Devices - ASME Available at: https://www.asme.org/codes-standards/find-codes-standards/v-v-40-assessing-credibility-computational-modeling-verification-validation-application-medical-devices [Accessed October 26, 2020]. BEN SALEM, M., and Tomaso, L. (2018). Automatic selection for general surrogate models. Struct. Multidiscip. Optim. Available at: https://hal.archives-ouvertes.fr/hal-01685848 [Accessed July 9, 2021]. Bianco, R.-J., Arnoux, P.-J., Mac-Thiong, J.-M., and Aubin, C.-E. (2019). Thoracic pedicle screw fixation under axial and perpendicular loadings: A comprehensive numerical analysis. Clin. Biomech. 68, 190–196. doi:10.1016/j.clinbiomech.2019.06.010. Bianco, R.-J., Arnoux, P.-J., Wagnac, E., Mac-Thiong, J.-M., and Aubin, C.-É. (2017). Minimizing Pedicle Screw Pullout Risks: A Detailed Biomechanical Analysis of Screw Design and Placement. Clin. Spine Surg. 30, E226–E232. doi:10.1097/BSD.0000000000000151. Biancolini, M. E. (2017). “RBF Mesh Morphing,” in Fast Radial Basis Functions for Engineering Applications, ed. M. E. Biancolini (Cham: Springer International Publishing), 93–117. doi:10.1007/978-3-319-75011-8_6. Biancolini, M. E., Capellini, K., Costa, E., Groth, C., and Celi, S. (2020). Fast interactive CFD evaluation of hemodynamics assisted by RBF mesh morphing and reduced order models: the case of aTAA modelling. Int. J. Interact. Des. Manuf. IJIDeM 14, 1227–1238. doi:10.1007/s12008-020-00694-5. Biswas, J. K., Sahu, T. P., Rana, M., Roy, S., Karmakar, S. K., Majumder, S., et al. (2019). Design factors of lumbar pedicle screws under bending load: A finite element analysis. Biocybern. Biomed. Eng. 39, 52–62. doi:10.1016/j.bbe.2018.10.003. Brunton, A., Salazar, A., Bolkart, T., and Wuhrer, S. (2016). “STATISTICAL SHAPE SPACES FOR 3D DATA: A REVIEW,” in Handbook of Pattern Recognition and Computer Vision (WORLD SCIENTIFIC), 217–238. doi:10.1142/9789814656535_0012. Caiazzo, A., Guibert, R., and Vignon-Clementel, I. E. (2016). A reduced-order modeling for efficient design study of artificial valve in enlarged ventricular outflow tracts. Comput. Methods Biomech. Biomed. Engin. 19, 1314–1318. doi:10.1080/10255842.2015.1133811. Calka, M., Perrier, P., Ohayon, J., Grivot-Boichon, C., Rochette, M., and Payan, Y. (2021). Machine-Learning based model order reduction of a biomechanical model of the human tongue. Comput. Methods Programs Biomed. 198, 105786. doi:10.1016/j.cmpb.2020.105786. Campbell, J. Q., and Petrella, A. J. (2015). An Automated Method for Landmark Identification and Finite-Element Modeling of the Lumbar Spine. IEEE Trans. Biomed. Eng. 62, 2709–2716. doi:10.1109/TBME.2015.2444811. Campbell, J. Q., and Petrella, A. J. (2016). Automated finite element modeling of the lumbar spine: Using a statistical shape model to generate a virtual population of models. J. Biomech. 49, 2593–2599. doi:10.1016/j.jbiomech.2016.05.013. Castro-Mateos, I., Pozo, J., Lazáry, A., and Frangi, A. (2016). Automatic construction of patient-specific finite-element mesh of the spine from IVDs and vertebra segmentations. doi:10.1117/12.2217343. Chen, S.-I., Lin, R.-M., and Chang, C.-H. (2003). Biomechanical investigation of pedicle screw–vertebrae complex: a finite element approach using bonded and contact interface conditions. Med. Eng. Phys. 25, 275–282. doi:10.1016/S1350-4533(02)00219-9. Chevalier, Y., Matsuura, M., Krüger, S., Fleege, C., Rickert, M., Rauschmann, M., et al. (2018). Micro-CT and micro-FE analysis of pedicle screw fixation under different loading conditions. J. Biomech. 70, 204–211. doi:10.1016/j.jbiomech.2017.12.023. Cho, W., Cho, S. K., and Wu, C. (2010). The biomechanics of pedicle screw-based instrumentation. J. Bone Joint Surg. Br. 92, 1061–1065. doi:10.1302/0301-620X.92B8.24237. Clogenson, M., Duff, J. M., Luethi, M., Levivier, M., Meuli, R., Baur, C., et al. (2015). A statistical shape model of the human second cervical vertebra. Int. J. Comput. Assist. Radiol. Surg. 10, 1097–1107. doi:10.1007/s11548-014-1121-x. Commandeur, F., Velut, J., and Acosta, O. (2011). A VTK Algorithm for the Computation of the Hausdorff Distance. VTK J., 839. Cootes, T. F., Taylor, C. J., Cooper, D. H., and Graham, J. (1995). Active Shape Models-Their Training and Application. Comput. Vis. Image Underst. 61, 38–59. doi:10.1006/cviu.1995.1004. Costa, M. C., Eltes, P., Lazary, A., Varga, P. P., Viceconti, M., and Dall’Ara, E. (2019). Biomechanical assessment of vertebrae with lytic metastases with subject-specific finite element models. J. Mech. Behav. Biomed. Mater. 98, 268–290. doi:10.1016/j.jmbbm.2019.06.027. Dall’Ara, E., Pahr, D., Varga, P., Kainberger, F., and Zysset, P. (2012). QCT-based finite element models predict human vertebral strength in vitro significantly better than simulated DEXA. Osteoporos. Int. J. Establ. Result Coop. Eur. Found. Osteoporos. Natl. Osteoporos. Found. USA 23, 563–572. doi:10.1007/s00198-011-1568-3. Dall’Ara, E., Peña-Fernández, M., Palanca, M., Giorgi, M., Cristofolini, L., and Tozzi, G. (2017). Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels. Front. Mater. 4. doi:10.3389/fmats.2017.00031. de Bruijne, M., Lund, M. T., Tankó, L. B., Pettersen, P. C., and Nielsen, M. (2007). Quantitative vertebral morphometry using neighbor-conditional shape models. Med. Image Anal. 11, 503–512. doi:10.1016/j.media.2007.07.004. Elmasry, S., Asfour, S., and Travascio, F. (2017). Effectiveness of pedicle screw inclusion at the fracture level in short-segment fixation constructs for the treatment of thoracolumbar burst fractures: a computational biomechanics analysis. Comput. Methods Biomech. Biomed. Engin. 20, 1412–1420. doi:10.1080/10255842.2017.1366995. Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., et al. (2012). 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn. Reson. Imaging 30, 1323–1341. doi:10.1016/j.mri.2012.05.001. Fields, A. J., Eswaran, S. K., Jekir, M. G., and Keaveny, T. M. (2009). Role of Trabecular Microarchitecture in Whole-Vertebral Body Biomechanical Behavior. J. Bone Miner. Res. 24, 1523–1530. doi:10.1359/jbmr.090317. Ganapathi, A., McCarron, J. A., Chen, X., and Iannotti, J. P. (2011). Predicting normal glenoid version from the pathologic scapula: a comparison of 4 methods in 2- and 3-dimensional models. J. Shoulder Elbow Surg. 20, 234–244. doi:10.1016/j.jse.2010.05.024. Gelaude, F., Clijmans, T., Broos, P. L., Lauwers, B., and Vander Sloten, J. (2007). Computer-aided planning of reconstructive surgery of the innominate bone: Automated correction proposals. Comput. Aided Surg. 12, 286–294. doi:10.3109/10929080701684762. Genant, H. K., Wu, C. Y., van Kuijk, C., and Nevitt, M. C. (1993). Vertebral fracture assessment using a semiquantitative technique. J. Bone Miner. Res. Off. J. Am. Soc. Bone Miner. Res. 8, 1137–1148. doi:10.1002/jbmr.5650080915. Gertzbein, S. D., and Robbins, S. E. (1990). Accuracy of Pedicular Screw Placement In Vivo. Spine 15, 11–14. Global Pedicle Screw System Market by Product, Surgery Type, Indication, Application, Region, Industry Analysis, Size, Share, Growth, Trends, and Forecast 2018 to 2025 - Fior Markets Available at: https://www.fiormarkets.com/report/global-pedicle-screw-system-market-by-product-polyaxial-375967.html [Accessed October 26, 2020]. Grassi, L., Hraiech, N., Schileo, E., Ansaloni, M., Rochette, M., and Viceconti, M. (2011). Evaluation of the generality and accuracy of a new mesh morphing procedure for the human femur. Med. Eng. Phys. 33, 112–120. doi:10.1016/j.medengphy.2010.09.014. Heimann, T., and Meinzer, H.-P. (2009). Statistical shape models for 3D medical image segmentation: a review. Med. Image Anal. 13, 543–563. doi:10.1016/j.media.2009.05.004. Hingsammer, A. M., Vlachopoulos, L., Meyer, D. C., and Fürnstahl, P. (2015). Three-dimensional corrective osteotomies of mal-united clavicles—is the contralateral anatomy a reliable template for reconstruction? Clin. Anat. 28, 865–871. doi:10.1002/ca.22572. Hoang, K. C., Khoo, B. C., Liu, G. R., Nguyen, N. C., and Patera, A. T. (2013). Rapid identification of material properties of the interface tissue in dental implant systems using reduced basis method. Inverse Probl. Sci. Eng. 21, 1310–1334. doi:10.1080/17415977.2012.757315. Ignasiak, D., Dendorfer, S., and Ferguson, S. J. (2016). Thoracolumbar spine model with articulated ribcage for the prediction of dynamic spinal loading. J. Biomech. 49, 959–966. doi:10.1016/j.jbiomech.2015.10.010. Inzana, J. A., Varga, P., and Windolf, M. (2016). Implicit modeling of screw threads for efficient finite element analysis of complex bone-implant systems. J. Biomech. 49, 1836–1844. doi:10.1016/j.jbiomech.2016.04.021. Kirschke, J. S., Löffler, M., and Sekuboyina, A. (2020). Verse 2020. Available at: https://osf.io/t98fz/ [Accessed March 11, 2021]. Kopperdahl, D. L., Morgan, E. F., and Keaveny, T. M. (2002). Quantitative computed tomography estimates of the mechanical properties of human vertebral trabecular bone. J. Orthop. Res. 20, 801–805. doi:10.1016/S0736-0266(01)00185-1. Krol, Z., Skadlubowicz, P., Hefti, F., and Krieg, A. H. (2013). Virtual reconstruction of pelvic tumor defects based on a gender-specific statistical shape model. Comput. Aided Surg. Off. J. Int. Soc. Comput. Aided Surg. 18, 142–153. doi:10.3109/10929088.2013.777973. Kumar, A., Aujla, R., and Lee, C. (2015). The management of thoracolumbar burst fractures: a prospective study between conservative management, traditional open spinal surgery and minimally interventional spinal surgery. SpringerPlus 4, 204. doi:10.1186/s40064-015-0960-4. Lauzeral, N., Borzacchiello, D., Kugler, M., George, D., Rémond, Y., Hostettler, A., et al. (2019). A model order reduction approach to create patient-specific mechanical models of human liver in computational medicine applications. Comput. Methods Programs Biomed. 170, 95–106. doi:10.1016/j.cmpb.2019.01.003. Li, C., Zhou, Y., Wang, H., Liu, J., and Xiang, L. (2014). Treatment of Unstable Thoracolumbar Fractures through Short Segment Pedicle Screw Fixation Techniques Using Pedicle Fixation at the Level of the Fracture: A Finite Element Analysis. PLoS ONE 9. doi:10.1371/journal.pone.0099156. Liebl, H., Schinz, D., Sekuboyina, A., Malagutti, L., Löffler, M. T., Bayat, A., et al. (2021). A Computed Tomography Vertebral Segmentation Dataset with Anatomical Variations and Multi-Vendor Scanner Data. ArXiv210306360 Cs Eess. Available at: http://arxiv.org/abs/2103.06360 [Accessed March 21, 2021]. Liu, H., Wang, H., Liu, J., Li, C., Zhou, Y., and Xiang, L. (2019). Biomechanical comparison of posterior intermediate screw fixation techniques with hybrid monoaxial and polyaxial pedicle screws in the treatment of thoracolumbar burst fracture: a finite element study. J. Orthop. Surg. 14, 122. doi:10.1186/s13018-019-1149-2. Löffler, M. T., Sekuboyina, A., Jacob, A., Grau, A.-L., Scharr, A., El Husseini, M., et al. (2020a). A Vertebral Segmentation Dataset with Fracture Grading. Radiol. Artif. Intell. 2, e190138. doi:10.1148/ryai.2020190138. Löffler, M. T., Sekuboyina, A., Jacob, A., Grau, A.-L., Scharr, A., El Husseini, M., et al. (2020b). A Vertebral Segmentation Dataset with Fracture Grading. Radiol. Artif. Intell. 2, e190138. doi:10.1148/ryai.2020190138. Luboz, V., Bailet, M., Boichon Grivot, C., Rochette, M., Diot, B., Bucki, M., et al. (2018). Personalized modeling for real-time pressure ulcer prevention in sitting posture. J. Tissue Viability 27, 54–58. doi:10.1016/j.jtv.2017.06.002. Luthi, M., Gerig, T., Jud, C., and Vetter, T. (2018). Gaussian Process Morphable Models. IEEE Trans. Pattern Anal. Mach. Intell. 40, 1860–1873. doi:10.1109/TPAMI.2017.2739743. Magerl, F., Aebi, M., Gertzbein, S. D., Harms, J., and Nazarian, S. (1994). A comprehensive classification of thoracic and lumbar injuries. Eur. Spine J. 3, 184–201. doi:10.1007/BF02221591. Mahar, A., Kim, C., Wedemeyer, M., Mitsunaga, L., Odell, T., Johnson, B., et al. (2007). Short-Segment Fixation of Lumbar Burst Fractures Using Pedicle Fixation at the Level of the Fracture. Spine 32, 1503–1507. doi:10.1097/BRS.0b013e318067dd24. Manzoni, A., Quarteroni, A., and Rozza, G. (2012). Model reduction techniques for fast blood flow simulation in parametrized geometries. Int. J. Numer. Methods Biomed. Eng. 28, 604–625. doi:10.1002/cnm.1465. Matsukawa, K., Yato, Y., Hynes, R. A., Imabayashi, H., Hosogane, N., Asazuma, T., et al. (2017). Cortical Bone Trajectory for Thoracic Pedicle Screws: A Technical Note. Clin. Spine Surg. 30, E497. doi:10.1097/BSD.0000000000000130. Matsukawa, K., Yato, Y., and Imabayashi, H. (2020). Impact of Screw Diameter and Length on Pedicle Screw Fixation Strength in Osteoporotic Vertebrae: A Finite Element Analysis. Asian Spine J. doi:10.31616/asj.2020.0353. Matsukawa, K., Yato, Y., Imabayashi, H., Hosogane, N., Abe, Y., Asazuma, T., et al. (2016). Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation? Acta Neurochir. (Wien) 158, 465–471. doi:10.1007/s00701-016-2705-8. Matsukawa, K., Yato, Y., Imabayashi, H., Hosogane, N., Asazuma, T., and Nemoto, K. (2015). Biomechanical evaluation of the fixation strength of lumbar pedicle screws using cortical bone trajectory: a finite element study. J. Neurosurg. Spine 23, 471–478. doi:10.3171/2015.1.SPINE141103. Mobbs, R. J., Sivabalan, P., and Li, J. (2011). Technique, challenges and indications for percutaneous pedicle screw fixation. J. Clin. Neurosci. 18, 741–749. doi:10.1016/j.jocn.2010.09.019. Molinari, L., and Falcinelli, C. (2021). On the human vertebra computational modeling: a literature review. Meccanica. doi:10.1007/s11012-021-01452-x. Molinari, L., Falcinelli, C., Gizzi, A., and Di Martino, A. (2021). Effect of pedicle screw angles on the fracture risk of the human vertebra: A patient-specific computational model. J. Mech. Behav. Biomed. Mater. 116, 104359. doi:10.1016/j.jmbbm.2021.104359. Monier-Faugere, M.-C., Chris Langub, M., and Malluche, H. H. (1998). “Chapter 8 - Bone Biopsies: A Modern Approach,” in Metabolic Bone Disease and Clinically Related Disorders (Third Edition), eds. L. V. Avioli and S. M. Krane (San Diego: Academic Press), 237–280e. doi:10.1016/B978-012068700-8/50009-8. Morgan, E. F., Bayraktar, H. H., and Keaveny, T. M. (2003). Trabecular bone modulus–density relationships depend on anatomic site. J. Biomech. 36, 897–904. doi:10.1016/S0021-9290(03)00071-X. Musuamba, F. T., Skottheim Rusten, I., Lesage, R., Russo, G., Bursi, R., Emili, L., et al. (2021). Scientific and regulatory evaluation of mechanistic in silico drug and disease models in drug development: building model credibility. CPT Pharmacomet. Syst. Pharmacol. Available at: https://eprints.whiterose.ac.uk/175265/ [Accessed December 14, 2021]. Nakahashi, M., Uei, H., Tokuhashi, Y., Maseda, M., Sawada, H., Soma, H., et al. (2019). Vertebral fracture in elderly female patients after posterior fusion with pedicle screw fixation for degenerative lumbar pathology: a retrospective cohort study. BMC Musculoskelet. Disord. 20, 259. doi:10.1186/s12891-019-2534-z. Newcomb, A. G. U. S., Baek, S., Kelly, B. P., and Crawford, N. R. (2017). Effect of screw position on load transfer in lumbar pedicle screws: A non-idealized finite element analysis. Comput. Methods Biomech. Biomed. Engin. 20, 182–192. doi:10.1080/10255842.2016.1209187. Niinomi, M., and Boehlert, C. J. (2015). “Titanium Alloys for Biomedical Applications,” in Advances in Metallic Biomaterials: Tissues, Materials and Biological Reactions Springer Series in Biomaterials Science and Engineering., eds. M. Niinomi, T. Narushima, and M. Nakai (Berlin, Heidelberg: Springer), 179–213. doi:10.1007/978-3-662-46836-4_8. Niroomandi, S., Alfaro, I., Cueto, E., and Chinesta, F. (2012). Accounting for large deformations in real-time simulations of soft tissues based on reduced-order models. Comput. Methods Programs Biomed. 105, 1–12. doi:10.1016/j.cmpb.2010.06.012. Niroomandi, S., Perrier, A., Bucki, M., and Payan, Y. (2020). “Chapter 5 - Real-time computer modeling in prevention of foot pressure ulcer using patient-specific finite element model and model order reduction techniques,” in Innovations and Emerging Technologies in Wound Care, ed. A. Gefen (Academic Press), 87–102. doi:10.1016/B978-0-12-815028-3.00005-5. Ovesy, M., Voumard, B., and Zysset, P. (2018). A nonlinear homogenized finite element analysis of the primary stability of the bone-implant interface. Biomech. Model. Mechanobiol. 17, 1471–1480. doi:10.1007/s10237-018-1038-3. Oxland, T. R., Lin, R.-M., and Panjabi, M. M. (1992). Three-Dimensional mechanical properties of the thoracolumbar junction. J. Orthop. Res. 10, 573–580. doi:https://doi.org/10.1002/jor.1100100412. Pahr, D. H., Schwiedrzik, J., Dall’Ara, E., and Zysset, P. K. (2014). Clinical versus pre-clinical FE models for vertebral body strength predictions. J. Mech. Behav. Biomed. Mater. 33, 76–83. doi:10.1016/j.jmbbm.2012.11.018. Palanca, M., Oliviero, S., and Dall’Ara, E. (2022). MicroFE models of porcine vertebrae with induced bone focal lesions: Validation of predicted displacements with digital volume correlation. J. Mech. Behav. Biomed. Mater. 125, 104872. doi:10.1016/j.jmbbm.2021.104872. Pascoletti, G., Aldieri, A., Terzini, M., Bhattacharya, P., Calì, M., and Zanetti, E. M. (2021). Stochastic PCA-Based Bone Models from Inverse Transform Sampling: Proof of Concept for Mandibles and Proximal Femurs. Appl. Sci. 11, 5204. doi:10.3390/app11115204. Perera, A., Qureshi, A., and Brecknell, J. E. (2015). Mono-segment fixation of thoracolumbar burst fractures. Br. J. Neurosurg. 29, 358–361. doi:10.3109/02688697.2014.987216. Perrier, A., Bucki, M., Luboz, V., Vuillerme, N., and Payan, Y. (2015). 3D musculoskeletal finite element analysis of the foot kinematics under muscle activation with and without ankle arthrodesis. Comput. Methods Biomech. Biomed. Engin. 18, 2022–2023. doi:10.1080/10255842.2015.1069605. Pesce, V., Piazzolla, A., Moretti, L., Carlucci, S., Parato, C., Maxy, P., et al. (2013). The vertebral biomechanic previous and after kyphoplasty. Aging Clin. Exp. Res. 25, 71–74. doi:10.1007/s40520-013-0073-2. Plessers, K., Berghe, P. V., Dijck, C. V., Wirix-Speetjens, R., Debeer, P., Jonkers, I., et al. (2018). Virtual reconstruction of glenoid bone defects using a statistical shape model. J. Shoulder Elbow Surg. 27, 160–166. doi:10.1016/j.jse.2017.07.026. Ponnusamy, K. E., Iyer, S., Gupta, G., and Khanna, A. J. (2011). Instrumentation of the osteoporotic spine: biomechanical and clinical considerations. Spine J. 11, 54–63. doi:10.1016/j.spinee.2010.09.024. Prud’homme, M., Barrios, C., Rouch, P., Charles, Y. P., Steib, J.-P., and Skalli, W. (2015). Clinical Outcomes and Complications After Pedicle-anchored Dynamic or Hybrid Lumbar Spine Stabilization: A Systematic Literature Review. J. Spinal Disord. Tech. 28, E439–E448. doi:10.1097/BSD.0000000000000092. Rajaee, S. S., Bae, H. W., Kanim, L. E. A., and Delamarter, R. B. (2012). Spinal fusion in the United States: analysis of trends from 1998 to 2008. Spine 37, 67–76. doi:10.1097/BRS.0b013e31820cccfb. Rijsbergen, M. van, van Rietbergen, B., Barthelemy, V., Eltes, P., Lazáry, Á., Lacroix, D., et al. (2018). Comparison of patient-specific computational models vs. clinical follow-up, for adjacent segment disc degeneration and bone remodelling after spinal fusion. PloS One 13, e0200899. doi:10.1371/journal.pone.0200899. Rohlmann, A., Bergmann, G., and Graichen, F. (1997). Loads on an internal spinal fixation device during walking. J. Biomech. 30, 41–47. doi:10.1016/S0021-9290(96)00103-0. Rohlmann, A., Graichen, F., Kayser, R., Bender, A., and Bergmann, G. (2008). Loads on a telemeterized vertebral body replacement measured in two patients. Spine 33, 1170–1179. doi:10.1097/BRS.0b013e3181722d52. Salhi, A., Burdin, V., Boutillon, A., Brochard, S., Mutsvangwa, T., and Borotikar, B. (2020). Statistical Shape Modeling Approach to Predict Missing Scapular Bone. Ann. Biomed. Eng. 48, 367–379. doi:10.1007/s10439-019-02354-6. Sanderson, P. L., Fraser, R. D., Hall, D. J., Cain, C. M. J., Osti, O. L., and Potter, G. R. (1999). Short segment fixation of thoracolumbar burst fractures without fusion. Eur. Spine J. 8, 495–500. doi:10.1007/s005860050212. Santoni, B. G., Hynes, R. A., McGilvray, K. C., Rodriguez-Canessa, G., Lyons, A. S., Henson, M. a. W., et al. (2009). Cortical bone trajectory for lumbar pedicle screws. Spine J. Off. J. North Am. Spine Soc. 9, 366–373. doi:10.1016/j.spinee.2008.07.008. Scalismo - Scalable Image and Shape Modelling | Scalismo Available at: https://scalismo.org/ [Accessed March 5, 2021]. Schileo, E., Dall’Ara, E., Taddei, F., Malandrino, A., Schotkamp, T., Baleani, M., et al. (2008). An accurate estimation of bone density improves the accuracy of subject-specific finite element models. J. Biomech. 41, 2483–2491. doi:10.1016/j.jbiomech.2008.05.017. Schousboe, J. T. (2016). Epidemiology of Vertebral Fractures. J. Clin. Densitom. 19, 8–22. doi:10.1016/j.jocd.2015.08.004. Sekuboyina, A., Bayat, A., Husseini, M. E., Löffler, M., Li, H., Tetteh, G., et al. (2020). VerSe: A Vertebrae Labelling and Segmentation Benchmark for Multi-detector CT Images. ArXiv200109193 Cs Eess. Available at: http://arxiv.org/abs/2001.09193 [Accessed March 5, 2021]. Sieger, D., Menzel, S., and Botsch, M. (2013). High Quality Mesh Morphing Using Triharmonic Radial Basis Functions. in Proceedings of the 21st International Meshing Roundtable, eds. X. Jiao and J.-C. Weill (Berlin, Heidelberg: Springer), 1–15. doi:10.1007/978-3-642-33573-0_1. Su, Y., Wang, X., Ren, D., Liu, Y., Liu, S., and Wang, P. (2018). A finite element study on posterior short segment fixation combined with unilateral fixation using pedicle screws for stable thoracolumbar fracture. Medicine (Baltimore) 97. doi:10.1097/MD.0000000000012046. Sun, X., Wang, H., Wang, W., Li, N., Hämäläinen, T., Ristaniemi, T., et al. (2021). A Statistical Model of Spine Shape and Material for Population-Oriented Biomechanical Simulation. IEEE Access, 1–1. doi:10.1109/ACCESS.2021.3129097. Taddei, F., Schileo, E., Helgason, B., Cristofolini, L., and Viceconti, M. (2007). The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements. Med. Eng. Phys. 29, 973–979. doi:10.1016/j.medengphy.2006.10.014. Ueno, M., Sakai, R., Tanaka, K., Inoue, G., Uchida, K., Imura, T., et al. (2015). Should we use cortical bone screws for cortical bone trajectory? J. Neurosurg. Spine 22, 416–421. doi:10.3171/2014.9.SPINE1484. unibas-gravis/scalismo (2021). Graphics and Vision Research Group University of Basel Available at: https://github.com/unibas-gravis/scalismo [Accessed March 5, 2021]. Van Meirhaeghe, J., Bastian, L., Boonen, S., Ranstam, J., Tillman, J. B., and Wardlaw, D. (2013). A Randomized Trial of Balloon Kyphoplasty and Nonsurgical Management for Treating Acute Vertebral Compression Fractures. Spine 38, 971–983. doi:10.1097/BRS.0b013e31828e8e22. Vanden Berghe, P., Demol, J., Gelaude, F., and Vander Sloten, J. (2017). Virtual anatomical reconstruction of large acetabular bone defects using a statistical shape model. Comput. Methods Biomech. Biomed. Engin. 20, 577–586. doi:10.1080/10255842.2016.1265110. Varghese, B., Short, D., Penmetsa, R., Goswami, T., and Hangartner, T. (2011). Computed-tomography-based finite-element models of long bones can accurately capture strain response to bending and torsion. J. Biomech. 44, 1374–1379. doi:10.1016/j.jbiomech.2010.12.028. Verma, K., Boniello, A., and Rihn, J. (2016). Emerging Techniques for Posterior Fixation of the Lumbar Spine. JAAOS - J. Am. Acad. Orthop. Surg. 24, 357–364. doi:10.5435/JAAOS-D-14-00378. Wang, E., Tran, K. L., D’heygere, E., and Prisman, E. (2021). Predicting the Premorbid Shape of a Diseased Mandible. The Laryngoscope 131, E781–E786. doi:https://doi.org/10.1002/lary.29009. Wang, H., Mo, Z., Han, J., Liu, J., Li, C., Zhou, Y., et al. (2018). Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures. Medicine (Baltimore) 97, e11244. doi:10.1097/MD.0000000000011244. Wang, J., Zhou, Y., Zhang, Z. F., Li, C. Q., Zheng, W. J., and Liu, J. (2013). Radiological study on disc degeneration of thoracolumbar burst fractures treated by percutaneous pedicle screw fixation. Eur. Spine J. 22, 489–494. doi:10.1007/s00586-012-2462-1. Wang, M. Y., Anderson, D. G., Poelstra, K. A., and Ludwig, S. C. (2008). MINIMALLY INVASIVE POSTERIOR FIXATION. Neurosurgery 63, A197–A203. doi:10.1227/01.NEU.0000320434.83458.10. Wang, W., Pei, B., Pei, Y., Shi, Z., Kong, C., Wu, X., et al. (2019). Biomechanical effects of posterior pedicle fixation techniques on the adjacent segment for the treatment of thoracolumbar burst fractures: a biomechanical analysis. Comput. Methods Biomech. Biomed. Engin. 22, 1083–1092. doi:10.1080/10255842.2019.1631286. Weese, J., Kaus, M., Lorenz, C., Lobregt, S., Truyen, R., and Pekar, V. (2001). Shape Constrained Deformable Models for 3D Medical Image Segmentation. in Information Processing in Medical Imaging Lecture Notes in Computer Science., eds. M. F. Insana and R. M. Leahy (Berlin, Heidelberg: Springer), 380–387. doi:10.1007/3-540-45729-1_38. Widmer, J., Fasser, M.-R., Croci, E., Spirig, J., Snedeker, J. G., and Farshad, M. (2020). Individualized prediction of pedicle screw fixation strength with a finite element model. Comput. Methods Biomech. Biomed. Engin. 23, 155–167. doi:10.1080/10255842.2019.1709173. Wirtz, D. C., Schiffers, N., Pandorf, T., Radermacher, K., Weichert, D., and Forst, R. (2000). Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. J. Biomech. 33, 1325–1330. doi:10.1016/S0021-9290(00)00069-5. Wood, K. B., Li, W., Lebl, D. S., and Ploumis, A. (2014). Management of thoracolumbar spine fractures. Spine J. 14, 145–164. doi:10.1016/j.spinee.2012.10.041. Wu, J., Cai, M., Li, J., Cao, L., Xu, L., Li, N., et al. (2019). Development and validation of a semi-automatic landmark extraction method for mesh morphing. Med. Eng. Phys. 70, 62–71. doi:10.1016/j.medengphy.2019.04.007. Xu, G., Fu, X., Du, C., Ma, J., Li, Z., Tian, P., et al. (2014). Biomechanical comparison of mono-segment transpedicular fixation with short-segment fixation for treatment of thoracolumbar fractures: A finite element analysis. Proc. Inst. Mech. Eng. [H] 228, 1005–1013. doi:10.1177/0954411914552308. Xu, Y., and Goodacre, R. (2018). On Splitting Training and Validation Set: A Comparative Study of Cross-Validation, Bootstrap and Systematic Sampling for Estimating the Generalization Performance of Supervised Learning. J. Anal. Test. 2, 249–262. doi:10.1007/s41664-018-0068-2. Yeung, S., Toor, A., Deib, G., Zhang, J., Besier, T., and Fernandez, J. (2020). Relationship between lower lumbar spine shape and patient bone metabolic activity as characterised by 18F NaF bio-markers. Comput. Biol. Med. 116, 103529. doi:10.1016/j.compbiomed.2019.103529. Zhang, J., Weir, V., Fajardo, L., Lin, J., Hsiung, H., and Ritenour, E. (2009). Dosimetric characterization of a cone-beam O-arm (TM) imaging system. J. X-Ray Sci. Technol. 17, 305–17. doi:10.3233/XST-2009-0231. Zindrick, M. R., Wiltse, L. L., Widell, E. H., Thomas, J. C., Holland, W. R., Field, B. T., et al. (1986). A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin. Orthop., 99–112. Zou, X. (2018). Simulation tools for biomechanical applications with PGD-based reduced order models. TDX Tesis Dr. En Xarxa. Available at: https://upcommons.upc.edu/handle/2117/116305 [Accessed November 24, 2021]. Zou, X., Conti, M., Díez, P., and Auricchio, F. (2018). A nonintrusive proper generalized decomposition scheme with application in biomechanics. Int. J. Numer. Methods Eng. 113, 230–251. doi:10.1002/nme.5610."],"dcterms:accessrights":["public"],"dc:title":["Computational models for the pre-operative planning of spinal surgeries"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000261331503"]},"updated_at":"2026-11-18T23:18:18Z"}