{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:30951"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:30951","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Investigation into the relationship between visual perception and instrumental colour measurement of teeth","abstract":"Individuals desire to seek aesthetic dental treatments such as restoration, dental fillings, and whitening treatments to obtain the ‘perfect’ smile has given rise to research to determine the most accurate method for tooth colour measurement. Accurate tooth colour measurement is essential in producing satisfactory results for restoration and fillings, improving communication between dentist and patient, as well as determining the efficacy of tooth whitening products. Currently there is no ‘gold’ standard method for assessing tooth colour. Gloss, curvature, small size, in vivo location and translucency are attributes of teeth which make accurate colour measurement difficult. The aim of this thesis is to evaluate ‘accuracy’ of tooth colour measurement by exploring some of the issues arising in visual perception, indices, and instrumental colour measurement. A yellowness index (YIO) is developed to assess changes in perceptual yellowness instead of whiteness which highlighted issues in indices and perceptual evaluation. The amount of edge-loss that occurs in the spectrophotometer, spectroradiometer, Vita EasyShade and digital camera was assessed to determine the amount of error produced by each measurement device. A novel approach to the assessment of accuracy is introduced whereby accuracy is expressed by the instrument’s ability to ‘agree’ with visual perception, with perceptual responses as the ‘reference’. Statistical analysis methods r2, percent wrong decisions and STRESS analysis are used in order to assess the correlation between instrumental measurement and visual perception responses (Z-scores). It was found that there is no ‘gold’ standard instrument, but there are indices that produce better correlation between instrumental measurement and visual perception. WIO and YIO produced the best results for the assessment in changes in tooth whiteness and tooth yellowness no matter which instrument was used. The Vita Easy Shade was found to perform poorly in comparison to all other instruments.","abstract_html":"Individuals desire to seek aesthetic dental treatments such as restoration, dental fillings, and whitening treatments to obtain the ‘perfect’ smile has given rise to research to determine the most accurate method for tooth colour measurement. Accurate tooth colour measurement is essential in producing satisfactory results for restoration and fillings, improving communication between dentist and patient, as well as determining the efficacy of tooth whitening products. Currently there is no ‘gold’ standard method for assessing tooth colour. Gloss, curvature, small size, in vivo location and translucency are attributes of teeth which make accurate colour measurement difficult. The aim of this thesis is to evaluate ‘accuracy’ of tooth colour measurement by exploring some of the issues arising in visual perception, indices, and instrumental colour measurement. A yellowness index (YIO) is developed to assess changes in perceptual yellowness instead of whiteness which highlighted issues in indices and perceptual evaluation. The amount of edge-loss that occurs in the spectrophotometer, spectroradiometer, Vita EasyShade and digital camera was assessed to determine the amount of error produced by each measurement device. A novel approach to the assessment of accuracy is introduced whereby accuracy is expressed by the instrument’s ability to ‘agree’ with visual perception, with perceptual responses as the ‘reference’. Statistical analysis methods r2, percent wrong decisions and STRESS analysis are used in order to assess the correlation between instrumental measurement and visual perception responses (Z-scores). It was found that there is no ‘gold’ standard instrument, but there are indices that produce better correlation between instrumental measurement and visual perception. WIO and YIO produced the best results for the assessment in changes in tooth whiteness and tooth yellowness no matter which instrument was used. The Vita Easy Shade was found to perform poorly in comparison to all other instruments.","abstract_has_math":false,"creators":["Sullivan, Chelsea Rose"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Westland, Stephen","Xiao, Kiada"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-01","date_published":"2022-01","updated_at":"2026-11-18T23:18:31Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000265811395"],"render_values":[{"text":"0000-0002-6581-1395","href":"https://orcid.org/0000-0002-6581-1395","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/30951/1/Sullivan_Thesis.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A30951","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Westland, Stephen","Xiao, Kiada"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Colgate-Palmolive"]},{"key":"dc:creator","label":"Author","values":["Sullivan, Chelsea Rose"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000265811395"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-01"]},{"key":"dc:date.issued","label":"Date","values":["2022-01"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Faculty of Arts, Humanities and Cultures (Leeds)","School of Design (Leeds)","Centre for Colour Design and Technology (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/30951/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. Abdi, H. and Williams, L.J. 2010. Principal Component Analysis. WIREs Computational Statistics. 2, pp.433-459. 2. Ahmad, I. 2006. Protocols for Predictable Aesthetic Dental Restorations. Oxford: Blackwell Munksgaard. 3. Ahn, J. and Lee, Y. 2008. Color distribution of shade guides in the value, chroma, and hue scale. The Journal of Prosthetic Dentistry. 100(1), pp. 18-28. 4. Al-Azzawi, A. 2007. Light and optics: principles and practices . Boca Raton, Florida: CRC/Taylor & Francis. 5. Al-Zarea, B. K. 2013. Satisfaction with Appearance and the Desired Treatment to Improve Aesthetics. International Journal of Dentistry. 2013, pp. 1-7. 6. Alkhatib, M. N., Holt, R. and Bedi, R. 2005. Age and perception of dental appearance and tooth colour. Gerodontology. 22, pp. 32-36. 7. Alqahtani, M. Q. 2014. Tooth-bleaching procedures and their controversial effects: A literature Review. The Saudi Dental Journal. 26, pp. 33-46. 8. ASTM E1164-12. 2017. ASTM E1164-12(2017):Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation. West Conshohocken, PA: ASTM International. 9. ASTM E1347-06. 2020. ASTM E1347-06: Standard Test Method for Color and Color-Difference Measurement by Tristimulus Colorimetry. West Conshohocken, PA: ASTM International. 10. ASTM E1349-06. 2018. ASTM E1349-06(2018): Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Bidirectional (45°:0° or 0°:45°) Geometry. West Conshohocken, PA: ASTM International. 11. ASTM E179-17. 2017. ASTM E179-17: Standard Guide for Selection of Geometric Conditions for Measurement of Reflection and Transmission Properties of Materials. West Conshohocken, PA: ASTM International. 12. ASTM E2466-13. 2013. ASTM E2466-13: Standard Test Method for Colorimetry of Teeth Using Digital Still Camera Technology. West Conshohocken, PA: ASTM International. 13. ASTM E2545-07. 2007. ASTM E2545-07: Standard Test Method for Objective Measurement of Gingival Color Using Digital Still Cameras. West Conshohocken, PA: ASTM International. 14. ASTM E308-18. 2001. ASTM E308-18: Standard Practice for Computing the Colors of Objects by Using the CIE System. West Conshohocken, PA: ASTM International. 15. ASTM E313-05. 2005. ASTM E313-05:Standard Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color Coordinates. E313-05. West Conshohocken, PA: ASTM International. 16. ASTM G138-12. 2012. ASTM G138-12: Standard Test Method for Calibration of a Spectroradiometer Using a Standard Source of Irradiance. West Conshohocken, PA: ASTM International. 17. Bahannan, S.A. 2014. Shade matching quality among dental students using visual and instrumental methods. Journal of Dentistry. 42, pp. 48-52. 18. Baltzer, A. and Kaufmann-Jinoian, V. 2004. The Determination Of The Tooth Colors. Quintessenz Zahntechnik.30(7), pp. 726-740. 19. Beltrami, R., Colombo, M., Chiesa, M., Bianchi, S. and Poggio, C. 2014. Scattering properties of a composite resin: Influence on color perception. Contemporary clinical dentistry, 5(4), pp.501–506. 20. Bengel, W. 2002. Mastering Dental Photography. Berlin, Germany: Quintessenz Verlags-GmbH. 21. Billmeyer, F.W. and Saltzman, M. 1981. Principles of color technology. 2nd ed. New York: Wiley. 22. Blair, J.J. 1985. Dental Restoration Shading. EP0154137 A1. 1985-09-11. 23. Blum, S., Horn, M. and Olms, C. 2018. A comparison of intraoral spectrophotometers—Are there user‐specific differences? Journal of Esthetic and Restorative Dentistry. 30(5), pp. 442–448. 24. Bolt, R. A., Ten Bosch, J. J. and Coops, J. C. 1994. Influence of window size in small-window colour measurement, particularly of teeth. Physics in Medicine and Biology. 39, pp. 1133-1142. 25. Bona, A. D., Barrett, A. A., Rosa, V. and Pinzetta, C. 2009. Visual and instrumental agreement in dental shade selection: Three distinct observer populations and shade matching protocols. Dental Materials. 25, pp. 276-281. 26. Brandt, J., Nelson, S., Lauer, H., von Hehn, U. and Brandt, S. 2017. In vivo study for tooth colour determination—visual versus digital. Clinical Oral Investigations, 21(9), pp. 2863–2871. 27. Brannan, D., Esplen, M. and Gray, J. 2011. Geometry. 2nd ed. Cambridge: Cambridge University Press. 28. Brook, A. H., Smith, R. M. and Lath, D. J. 2007. The clinical measurement of tooth colour and stain. International Dental Journal. 57, pp. 324-330. 29. Burkinshaw, S. 2004. Colour in relation to dentistry. Fundamentals of colour science. British Dental Journal. 196(1), pp. 33–41. 30. Cal, E., Sonugelen, M., Guneri, P., Kesercioglu, A. and Kose, T. 2004. Application of a digital technique in evaluating the reliability of shade guides. Journal of Oral Rehabilitation. 31(5), pp. 483–491. 31. Carey, C. 2014. Tooth Whitening: What we now know. Journal of evidence-based dental practice special issue -annual report on dental hygiene. 14(1), pp. 70-76. 32. Cho, B., Lim, Y. and Lee, Y. 2007. Comparison of the color of natural teeth measured by a colorimeter and Shade Vision System. Dental Materials. 23(10), pp. 1307–1312. 33. Chu, S.J. 2007. Range And Mean Distribution Frequency Of Individual Tooth Width Of The Maxillary Anterior Dentition. Practical Procedures In Aesthetic Dentistry. 19(4), Pp. 209-215. 34. Chu, S.J. and Okubo, S. 2008. Range and mean discordance of individual tooth width of the mandibular anterior dentition. Practical Procedures in Aesthetic Dentistry. 20(5), pp. 313-320. 35. Chu, S.J., Trushkowsky, R.D. and Paravina, R.D.. 2010. Dental color matching instruments and systems: review of clinical and research aspects. Journal of dentistry. 38s, pp. E2-e16. 36. Church, T., Jessup, J.P., Guillory, V.L and Vandewalle, K.S. 2017. Translucency and strength of high-translucency monolithic zirconium oxide materials. General Dentistry. (398), pp. 48-52. 37. CIE 15. 2004. CIE 15: Colorimetry Technical Report. Commission Interntionale de l’Eclairage. Vienna, Austria: CIE Central Bureau. 38. CIE 217. 2016. CIE 217: Recommended Method for Evaluating the Performance of Colour-Difference Formulae Technical Report. Commission Interntionale de l’Eclairage. Vienna, Austria: CIE Central Bureau. 39. Clarke, F. J. and Parry, D. 1985. Helmholtz Reciprocity: Its validity and application to reflectometry. Lighting Research & Technology (1969). 17(1), 1–11. 40. Colgate-Palmolive Company. 2021. Optic White Renewal Toothpaste. [Online]. [7 July 2021]. Available from: https://www.colgate.com/en-us/products/toothpaste/ow-renewal 41. Collins, L.Z., Naeeni, M., and Platten, S.M. 2008. Instant tooth whitening from a silica toothpaste containing blue covarine. Journal of Dentistry. 36s, pp. S21-S25. 42. Curd, F.M., Jasinevicius, T.R., Graves, A., and Cox, V. 2006. Comparison of the shade matching ability of dental students using two light sources. Journal of Prosthetic Dentistry. 96(6), pp. 391-396. 43. Da Silva, J. D., Park, S. E., Weber, H. and Ishikawa-Nagai, S. 2008. Clinical Performance of a newly developed spectrophotometric system on tooth colour reproduction. The Journal of Prosthetic Dentistry. 99(5). pp. 361-368. 44. De Bragança, R.M., Moraes, R.R. and Faria-e-Silva, A.L. 2021. Color assessment of resin composite by using cellphone images compared with a spectrophotometer. Restorative Dentistry & Endodontics. 46, pp. e23. 45. del Mar Pérez, M., Ghinea, R., Rivas, M.J., Yebra, A., Ionescu, A.M., Paravina, R.D. and Herrera, L.J. 2016. Development of a customized whiteness index for dentistry based on CIELAB colour space. Dental Materials. 32, pp. 461-467. 46. Ebner, M. ed. 2007. Color Constancy. West Sussex: John Wiley & Sons, Ltd. 47. Elamin, H.O., Abubakr, N.H. and Ibrahim, Y.E. 2015. Identifying the tooth shade in group of patients using Vita EasyShade. European Journal of Dentistry. 9(2), pp. 213-217. 48. Finlayson, G., and Zhu, Y. 2019. Finding a Colour Filter to Make a Camera Colorimetric by Optimisation. In: Computational Color Imaging, 27-29 March 2019, Japan. Switzerland: Springer International Publishing, pp. 53-62. 49. Flucke, J. 2021. The Future of Teeth Whitening. Dental Products Report. 55(10), pp. 22-23. 50. García, P.A., Huertas, R., Melgosa, M. and Cui, G. 2007. Measurement of the relationship between perceived and computed color difference. Journal of the Optical Science of America A. 24(7), pp. 1823-1829. 51. German, D.S., Chu, S.J., Fulong, M.L. and Patel, A. 2016. Simplifying optimal tooth-size calculations and communications between practitioners. American Journal of Orthodontics and Dentofacial Orthopedics. 150(6), pp. 1051-1055. 52. Gevaux, L., Simonot, L., Clerc, R., Gerardin, M. and Hebert, M. 2020. Evaluating edge loss in the reflectance measurement of translucent materials. Applied Optics. Optical Technology and Biomedical Optics. 59(28), pp. 8939–8950. 53. Gómez-Polo, C., Gómez-Polo, M., Celemin-Viñuela, A. and Martínez Vázquez De Parga, J. 2014. Differences between the human eye and the spectrophotometer in the shade matching of tooth colour. Journal of Dentistry. 42(6), pp. 742–745. 54. Gómez-Polo, C., Muñoz, M.P., Lorenzo Luengo, M.C., Vicente, P., Galindo, P. and Martín Casado, A.M. 2015. Comparison of the CIELab and CIEDE2000 color difference formulas. Journal of Prosthetic Dentistry. 115(1), pp. 65-70. 55. Gozalo-Diaz, D.J., Lindsey, D.T., Johnston, W.M. and Wee, A.G. 2007. Measurement of color for craniofacial structures using a 45/0-degree optical configuration. Journal of Prosthetic Dentistry. 97(1), pp.45-53. 56. Grand View Research. 2021. Oral Care Market Size, Share and Trends Report. [Online]. Market Analysis Report: Grand View Research. [Accessed 31 October 2021]. Available from: https://www.grandviewresearch.com/industry-analysis/oral-care-market 57. Guan, Y. H., Lath, D. L., Lilley, T. H., Willmot, D. R., Marlow., I. and Brook, A.H. 2005. The measurement of tooth whiteness by image analysis spectrophotometry: a comparison. Journal of Oral Rehabilitation. 32, pp. 7-15. 58. Gupte, V.C. 2010. Expressing colours numerically. In: Gulrajani, M. L., Colour measurement Principles, advances and industrial applications. Oxford: Woodhead Publishing Limited. 59. Hammad, I. A. 2003. Intrarater repeatability of shade selections with two shade guides. The Journal of Prosthetic Dentistry. 89(1), pp. 50-53. 60. He, L. and Nahar, V. 2016. Reuse of scientific data in academic publications: An investigation of Dryad Digital Repository. Aslib Journal of Information Management. 68(4), pp. 478–494. 61. He, W., Park, C., Byun, S., Tan, D., Lin, C. and Chee, W. 2020. Evaluating the relationship between tooth color and enamel thickness, using twin flash photography, cross‐polarization photography, and spectrophotometer. Journal of Esthetic and Restorative Dentistry. 32(1), pp. 91–101. 62. Hess, A.S. and Hess, J.R. 2018. Principal Component Analysis. Transfusion. 58, pp.1580-1582. 63. Hirschen, R. 2010. Visual and Instrumental Evaluation of whiteness and yellowness. In: Gulrajani, M. L., Colour measurement Principles, advances and industrial applications. Oxford: Woodhead Publishing Limited. 64. Höfel, L, Lange, M. and Jacobsen, T. 2007. Beauty and the teeth: perception of tooth color and its influence on the overall judgment of facial attractiveness. The International Journal of Periodontics & Restorative Dentistry. 27(4), pp. 349–357. 65. Hogan, R. 2021. Email Response to Chelsea Sullivan, 29 January 2021. 66. Howitt, D. and Cramer, D. 2014. Introduction to Statistics in Psychology. 6th ed. Harlow, England: Pearson. 67. Hughes, G. 2017. Sharing research data. Emergency Medicine Australasia. 29, pp. 4-5. 68. Hunt, R.W.G and Pointer, M.R. 2011. Measuring Colour. 4th Ed. West Sussex: John Wiley & Songs, Ltd. 69. Hunter, R. S. 1981. Conversion of Visual to Instrumental Measurement of Yellowness. Journal of the American Oil Chemists’ Society. 59(5), pp. 608-612 70. Jarad, F., Russell, M. and Moss, B. 2005. The use of digital imaging for colour matching and communication in restorative dentistry. British Dental Journal. 199(1), pp. 43–49. 71. Jeng, Y., Lin, T., Hsu, H., Chang, H. and Shieh, D. 2011. Human enamel rod presents anisotropic nanotribiological properties. Journal of the mechanical behavior of biomedical materials. 4, pp. 515-522. 72. Johnston, W. M. 2009. Color measurement in dentistry. Journal of Dentistry. 37s, pp. e2-e6. 73. Johnston, W.M., Hesse, N.S., Davis, B.K. and Seghi, R.R. 1996. Analysis of Edge-losses in Reflectance Measurements of Pigmented Maxillofacial Elastomer. Journal of Dental Research. 75(2), pp. 752-760. 74. Joiner, A. 2004. Tooth Colour: A Review Of The Literature. Journal Of Dentistry. 32, pp. 3-12 75. Joiner, A. 2010. Whitening toothpastes: A review of the literature. Journal of Dentistry. 38s, pp. e17-e24. 76. Joiner, A. and Luo, W. 2017. Tooth colour and whiteness: A review. Journal of Dentistry. 67, pp. S3-S10. 77. Joiner, A., Hopkinson, I., Deng, Y. and Westland, S. 2008a. A review of tooth colour and whiteness. Journal of Dentistry. 36s, pp. S2-S7. 78. Joiner, A., Philpotts, C.J., Alonso, C., Ashcroft, A.T. and Sygrove, N J. 2008b. A novel optical approach to achieving tooth whitening. Journal of dentistry. 36, pp. 8-14. 79. Kershaw, S., Newton, J. and Williams, D. 2008. The influence of tooth colour on the perceptions of personal characteristics among female dental patients: comparisons of unmodified, decayed and ‘whitened’ teeth. British Dental Journal. 204(E9). 80. Khashayar, G., Bain, P., Salari, S., Dozic, A., Kleverlaan, C. and Feilzer, A. 2014. Perceptibility and acceptability thresholds for colour differences in dentistry. Journal of Dentistry. 42(6), pp. 637–644. 81. Khashayar, G., Dozic, A., Kleverlaan, C.J. and Feilzer, A.J. 2012. Data comparison between two dental spectrophotometers. Operative Dentistry. 37(1), pp.12-20. 82. Khurana, R., Tredwin, C.J., Weisbloom, M. and Moles, D. R. 2007. A clinical evaluation of the individual repeatability of three commercially available colour measuring devices. British Dental Journal. 203(12), pp. 3-12. 83. Kim-Pusateri, S., Brewer J. D., Davis, E. L. and Wee, A. G. 2009. Reliability and Accuracy of four dental shade-matching devices. The Journal of Prosthetic Dentistry. 101(3), pp. 193-199. 84. Kim, J. Yu, B. and Lee, Y. 2008. Influence of surface layer removal of shade guide tabs on the measured color by spectrophotometer and spectroradiometer. Journal of Dentistry. 36, pp. 1061-1067. 85. Kim, M., Kim, B., Park, B., Lee, M., Won, Y., Kim, C. and Lee, S. 2018. A Digital Shade-Matching Device for Dental Color Determination Using the Support Vector Machine Algorithm. Sensors. 18(9), pp. 3051. 86. Kim, S.T., Abbott, P.V. and McGinley, P. 2000. The effects of Ledermix paste on discolouration of mature teeth. International Endodontic Journal. 33(3), 227–232. 87. Kim, Y., Son, H., Yi, K., Kim, H., Ahn, J. and Chang, J. 2013. The color change in artificial white spot lesions measured using a spectroradiometer. Clinical Oral Investigations. 17, pp. 139-146. 88. Kingdom, F.A.A. and Prins, N. 2010. Psychophysics: A Practical Introduction. London: Elsevier Ltd 89. Kirchner, E. and Dekker, N. 2011. Performance measures of color-difference equations: correlation coefficient versus standardized residual sum of squares. Journal of the Optical Science of America A. 28(9), pp. 1841-1848. 90. Klotz, A., Habibi, Y., Corcodel, N., Rammelsberg, P., Hassel, A.J. and Zenthöfer, A. 2018. Laboratory and clinical reliability of two spectrophotometers. Journal of Esthetic and Restorative Dentistry. Pp., 1-5. 91. Knight, R.D. 2008. Physics for Scientists and Engineers: A strategic Approach. 2nd ed. Upper Saddle River, NJ: Pearson. 92. Konica Minolta Sensing Americas Inc., 2020. Color Measurement Instrument Geometries. Konica Minolta Sensing America. [Online]. [Accessed 10 August 2020]. Available from: https://sensing.konicaminolta.us/us/blog/color-measurement-instrument-geometries/ 93. Konica Minolta. 2007. Spectroradiometer CS-2000/CS-2000A. [Instruction Manual]. United States: Konica Minolta, Inc. 94. Konica Minolta. 2014. Spectrophotometer CM-2600d/2500d. [Instruction Manual]. Japan: Konica Minolta, Inc. 95. Konica Minolta. 2015. Precise color communication; color control from perception to instrumentation. [Booklet]. Japan: Konica Minolta, Inc. 96. Konica Minolta. 2016a. Spectrophotometer CM-25cG. [Instruction Manual]. United Kingdom: Konica Minolta, Inc. 97. Konica Minolta. 2016b. Spectrophotometer CM-M6. [Instruction Manual]. United States: Konica Minolta, Inc. 98. Konica Minolta. 2019. Specular Component Included (SCI) vs. Specular Component Excluded (SCE). 24 January. Colour Measurement. [Online]. [Accessed 27 July 2020]. Available from: https://sensing.konicaminolta.asia/specular-component-included-sci-vs-specular-component-excluded-sce/ 99. Koumpia, E., Athanasiou, A.E., Eliades, T. and Knösel, M. 2018. Precision of a reflectance spectrophotometer in measuring anterior tooth colour. The Open Dental Journal. 12, pp. 884-895. 100. Kovacevic Pavicic, D., Pavlic, A., Kinkela Devcic, M., Lajnert, V. and Spalj, S. 2017. Tooth Color as a Predictor of Oral Health‐Related Quality of Life in Young Adults. Journal of Prosthodontics. 28(4), pp. e886–e892. 101. Kruskal, J.B. 1964. Multidimensional scaling by optimizing goodness of fit to a nonmetric hypothesis. Pychometrika. 29, pp. 1–27. 102. Kuehni, R. G. 2003. Color Space and Its Divisions: Color Order from Antiquity to the present. Hoboken, New Jersey: John Wiley & Sons Inc. 103. Langlais, R.P., Miller, C.S. and Nield-gehrig, J.S. 2009. Color Atlas of Common Oral Diseases. 4th ed. Philadelphia, PA: Lippincott Williams & Wilkins. 104. Lasseree, J., Pop-Ciutrila, I. and Colosi, H. 2011. A comparison between a new visual method of colour matching by intraoral camera and conventional visual and spectrometric methods. Journal of Dentistry. 39s, pp. e29-e36. 105. Lee, Y. and Powers, J.M. 2005. Comparison of CIE Lab, CIEDE 2000, and DIN 99 Color Differences Between Various Shade of Resin Composites. The International Journal of Prosthodontics. 18(2), pp. 150-155. 106. Lee, Y.K., Lim, B.S., and Kim, C.W. 2004. Influence of illuminating and viewing aperture size on the color of dental resin composites. Dental Materials. 20(2), pp. 116–123. 107. Lee, Y.K., Yu, B., Lim, J. I. and Lim, H. 2011. Perceived color shift of a shade guide according to the change of illuminant. The Journal of Prosthetic Dentistry. 105(2), pp. 91-99. 108. Lehmann, K.M., Igiel, C., Schmidtmann, I. and Scheller, H. 2010. Four color-measuring devices compared with a spectrophotometric reference system. Journal of Dentistry. 38s, pp. e65-e70. 109. Lim, H., Yu, B., Lim, J. and Lee, Y. 2010. Correlations between spectroradiometric and spectrophotometric colors of all-ceramic materials. Dental Materials. 26(11), pp. 1052–1058. 110. Luo, M., Cui, G. and Rigg, B. 2001. The development of the CIE 2000 colour-difference formula: CIEDE2000. Color Research and Application. 26(5), pp 340–350. 111. Luo, R. M. 2011. The quality of light sources. Coloration Technology. 127, pp. 85-87. 112. Luo, W., Naeeni, M., Platten, S., Wang, J., Sun, J.N., Westland, S. and Joiner, A. 2017. The in vitro and in vivo reproducibility of video-based digital imaging system for tooth colour measurement. Journal of Dentistry. 67, pp. S15-S19. 113. Luo, W., Westland, S., Brunton, P., Ellwood, R., Pretty, I. A. and Mohan, N. 2007. Comparison of the ability of different colour indices to assess changes in tooth whiteness. Journal of Dentistry. 35, pp. 109-116. 114. Luo, W., Westland, S., Ellwood, R., Pretty, I. and Cheung, V. 2009. Development of a whiteness index for dentistry. Journal of Dentistry. 37s, pp. e21-e26. 115. MacAdam, D.L. 1942. Visual Sensitivity to Color Differences in Daylight. Journal of the Optical Socieiety of America. 32(5), pp. 247-274. 116. MacDonald, R. 1980. Industrial pass/fail color matching. Part I. Preparation of visual color-matching data. Journal of Society of Dyers and Colorists. 96, Pp. 372–376. 117. Mackie, I.C. and Blinkhorn, A. 1995. Oral Health Prevention of Dental Disease. Manchester, United Kingdom: Oral Health and Development University Dental Hospital of Manchester. 118. Mahn, E., Tortora, S., Olate, B., Cacciuttolo, F., Kernitsky, J., and Jorquera, G. 2021. Comparison of visual analog shade matching, a digital visual method with a cross-polarized light filter, and a spectrophotometer for dental color matching. The Journal of Prosthetic Dentistry. 125(3), pp. 511–516. 119. Malacara, D. 2002. Color Vision and Colorimetry: theory and applications. Washington: SPIE Press. 120. Marques Junior, R.B., Baroudi, K., Campos dos Santos, A.F., Pontes, D. and Amaral, M. 2021. Tooth Discoloration Using Calcium Silicate-Based Cements For Simulated Revascularization in Vitro. Brazilian Dental Journal. 32(1), pp. 53-58. 121. Martínez-Verdú, F., Chorro, E., Parales, E., Vilaseca, M. and Pujol, J. 2010. Camera-based colour measurement. In: Gulrajani, M. L., Colour measurement Principles, advances and industrial applications. Oxford: Woodhead Publishing Limited. 122. Mazur, M., Westland, S., Jedliński, M., Maruotti, A., Nardi, G., Ottolenghi, L. and Guerra, F. 2020. The Influence of Dental Occlusion on Spectrophotometric Tooth Color Determinations. The Open Dentistry Journal. 14, pp. 247-254. 123. McDonald, R. 1997. Colour Physics for Industry. 2nd ed. Bradford: Society of Dyers and Colourists. 124. McLaren, K. 1970. Colour Passing - Visual or Instrumental. Journal of Society of Dyers and Colourists. 86(9), pp. 389-392 125. Melgosa, M., Alman, D., Grosman, M., Gómez-Robledo, L., Trémeau, A., Cui, G., García, P., Vázquez, D., Li, C. and Luo, M. 2013. Practical demonstration of the CIEDE2000 corrections to CIELAB using a small set of sample pairs. Color Research and Application. 38(6), 429–436. 126. Melgosa, M., Huertas, R. and Berns, R.S. 2008. Performance of recent advanced color-difference formulas using the standardized residual sum of squares index. Journal of the Optical Science of America A. 25(7), pp. 1828-1834. 127. Mello, M.M., Lieou, V. and Goodman, S.N. 2018. Clinical Trial Participants’ Views of the Risks and Benefits of Data Sharing. The New England Journal of Medicine. 378, pp. 2202-2211. 128. Mishchenko, M.I., Travis, L.D. and Lacis, A.A. 2002. Scattering, absorption, and emission of light by small particles. Bambridge: Cambridge University Press. 129. Mohan, N., Westland, S., Brunton, P., Ellwood, R., Pretty, I.A. and Wen, L. 2008. A clinical study to evaluate the efficacy of a novel tray based tooth whitening system. Journal of Dentistry. 26, pp. 21-26. 130. Montero, J., Gomez-Polo, C., Santos, J. A., Portillo, M., Lorenzo, M. C. and Albaladejo, A. 2014. Contributions of dental color to the physical attractiveness stereotype. Journal of Oral Rehabilitation. 41, pp. 768-782. 131. Nassau, K. 1998. Color for science, art and technology. Amsterdam, Netherlands: Elsevier. 132. National Library of Medicine. 2021. Data Reuse. [Online]. [Accessed 1 February 2021]. Available from: https://nnlm.gov/data/thesaurus/data-reuse 133. Nedelcu, R., Olsson, P., Nyström, I., Rydén, J. and Thor, A. 2018. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method. Journal of Dentistry. 69, pp. 110-118. 134. O’Brien, W.J., Groh, C.L. and Boenke, K.M. 1990. A new, small-color-difference equation for dental shades. Journal of Dental Research. 69(11), pp. 1762-1764. 135. Odioso L.L., Gibb, R.D. and Gerlach, R.W. 2000. Impact of demographic, behavioural, and dental care utilization parameters on tooth color and personal satisfaction. Compendium of Continuing Education in Dentistry. 21(29), pp. S35—S41. 136. Oguro, R., Nakajima, M., Seki, N., Sadr, A., Tagami, J. and Sumi, Y. 2016. The role of enamel thickness and refractive index on human tooth colour. Journal of Dentistry. 51, pp. 36-44. 137. Oleari, C. 2016. Standard Colorimetry: Definitions, Algorithms and Sotware. United Kingdom: John Wiley & Sons, Ltd. 138. Oliveira, D., Ayres, A., Rocha, M., Giannini, M., Puppin Rontani, R., Ferracane, J. and Sinhoreti, M. 2015. Effect of Different In Vitro Aging Methods on Color Stability of a Dental Resin‐Based Composite Using CIELAB and CIEDE2000 Color‐Difference Formulas. Journal of Esthetic and Restorative Dentistry. 27(5), pp. 322–330 139. Palumbo, P.A. and Weber, W.L. 1999. Novel spectrophotometer for the measurement of colour and appearance. Analytica Chimica Acta. 380(2), 243-261. 140. Pan, Q. and Westland, S. 2018. Tooth colour and whitening – digital technologies. Journal of Dentistry. 74(1), pp. S42-S46. 141. Pan, Q., Westland, S. and Ellwood, R. 2018. Evaluation of colorimetric indices for the assessment of tooth whiteness. Journal of Dentistry. 76, pp. 132-136. 142. Parameswaran, V., Anilkumar, S., Lylajam, S., Rajesh, C. and Narayan, V. 2016. Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems. The Journal of Indian Prosthodontic Society. 16(4), pp. 352–358. 143. Paravina, R. D. 2008. New Shade Guide for Tooth Whitening Monitoring: Visual Assessment. The Journal of Prosthetic Dentistry. 99(3), pp. 178-184. 144. Paravina, R., Ghinea, R., Herrera, L., Bona, A., Igiel, C., Linninger, M., Sakai, M., Takahashi, H., Tashkandi, E. and Del Mar Perez, M. 2015. Color Difference Thresholds in Dentistry: Color Difference Thresholds. Journal of Esthetic and Restorative Dentistry. 27, pp. S1–S9. 145. Paravina, R.D. and Powers, J. 2004. Esthetic color training in dentistry. St. Louise, MO: Elsevier Mosby. 146. Paravina, R.D., Aleksić, A., Tango, R.N., García-Beltrán, Johnston, W.M. and Ghinea, R.I. 2021. Harmonization of color measurements in dentistry. Measurement. 169, pp. 108504 147. Paravina, R.D., O’Keefe, K.L. and Kuljic, B.L. 2006. Color of permanent teeth: a prospective clinical study. Balkan Journal of Stomatology. 10, pp. 93–97. 148. Pasquetto, I.V., Sands, A.E. and Borgman, C. L. 2015. Exploring Openness in Data and Science: What is “Open,” to Whom, When, and Why?. Proceedings of the Association for Information Science and Technology. 52(1), pp. 1-2. 149. Paul, S., Peter, A., Pietrobon, N. and Hämmerle, C. 2002. Visual and Spectrophotometric Shade Analysis of Human Teeth. Journal of Dental Research. 81(8), pp. 578–582. 150. Pérez, M., Ghinea, R., Rivas, M.J., Yebra, A., Ionescu, A.M., Paravina, R.D. and Herrera, L.J. 2016. Development of a customized whiteness index for dentistry based on CIELAB colour space. Dental Materials. 32, pp. 461-467. 151. Piwowar, H.A. and Vision, T.J. 2013. Data reuse and the open data citation advantage. PeerJ. 1, pp. e175. 152. Pop-Ciutrila, I. S., Ghinea, R., Colori, H. A. and Dunea, D. 2016. Dentin translucency and color evaluation in human incisors, canines, and molars. Journal of Prosthetic Dentistry. 115(4), pp. 475-481. 153. Purdue, 2015. F Critical Values Table. [Online]. [Accessed 20 September 2018]. Available from: https://www.stat.purdue.edu/~jtroisi/STAT350Spring2015/tables/FTable.pdf 154. Rasmussen, C.M. 2019. Market Analysis 2020 on 26th World Congress on Dentistry and Oral Health. Journal of Oral Medicine. 3(5). 155. Rauf, W. 2020. Email response to Chelsea Sullivan, 20 July 2020. 156. Rubio, L., Sioli, J.M., Suarez, J., Gaitan, M. J. and Martin-de-las-Heras, S. 2015. Spectrophotometric analysis of color changes in teeth incinerated at increasing temperatures. Forensic Science International. 252, pp. 193.e1–193.e6. 157. Schmidseder, J. 2000. Aesthetic Denistry. New York: Thieme Stuttgart. 158. Seghi, R.R. 1990. Effects of Instrument-measuring geometry on Colorimetric Assessments of Dental Porcelains. Journal of Dental Restorations. 69(5), pp. 1180-1183. 159. Sindi, K.H., Bubb, N.L., Gutteridge, D.L. and Evans, J.A. 2015. In vitro enamel thickness measurements with ultrasound. Ultrasound in Medicine and Biology. 41(1), pp. 301-308. 160. Stratview Research, 2020. Global Teeth Whitening Products Market, Dynamics, and Market Analysis. Radian Offshore Consultanacy LLP. 161. Sullivan, C., Pan, Q., Westland, S. and Ellwood, R. 2019. A yellowness index for use in dentistry. Journal of Dentistry. 91, pp. 103244. 162. Tao, D., Smith, R.N., Zhang, Q., Sun, J.N., Philpotts, C.J., Ricketts, S.R., Naeeni, M. and Joiner, A. 2017a. Tooth whitening evaluation of blue covarine containing toothpastes. Journal of Dentistry. 67, pp. S20-S24. 163. Tao, D., Sun, J.N., Wang, X., Zhang, Q., Naeeni, M.A., Phipotts, C.J. and Joiner, A. 2017b. In vitro and clinical evaluation of optical tooth whitening toothpastes. Journal of Dentistry. 67, pp. S25–S28. 164. Ten Bosch J.J. and Coops J.C. 1995. Tooth color and reflectance as related to light scattering and enamel hardness. Journal of Dental Research. 74(1), pp. 74-80. 165. Thurstone, L.L. 1927. Psychophysical Analysis. The American Journal of Psychology. 38(3), pp. 368-389. 166. Tin-Oo, M., Saddki, N. and Hassan, N. 2011. Factors influencing patient satisfaction with dental appearance and treatments they desire to improve aesthetics. BMC Oral Health. 11(6). 167. Tsukida, K. and Gupta, M.R. 2011. How to Analyze Paired Comparison Data. UWEETR-2011-0004 Electrical Engineering. May 2011, University of Washington Department of Electrical Engineering. 168. Tung, F. F., Goldstein, G. R., Jang, S. and Hittelman, E. 2002. The repeatability of an intraoral dental colorimeter. The Journal of Prosthetic Dentistry. 88(6), pp. 585-590. 169. Vallittu, P. K., Vallittu, A. S. and Lassila, V. P. 1996. Dental aesthetics – a survey of attitudes in different groups of patients. Journal of Dentistry. 24(5), pp. 335-338. 170. VeriVide. 2008. Powerful, fast and flexible colour management: DigiEye can evaluate objects previously considered unmeasurable. [Leaflet]. Leicester: Verivide. 171. VeriVide. 2020. DigiEye System: Non-contact digital colour measurement and imaging system. [Product Specification Leaflet]. Leicester, United Kingdom: VeriVide. 172. VITA North America. 2022. VITA classical Shade Guide. [Online]. [Accessed 22 May 2022]. Available from: https://www2.vitanorthamerica.com/products/shade-management/vita-classical-previously-the-lumin-vacuum-shade-guide/ 173. VITA Zahnfabrik. 2013. VITA Easyshade Advance 4.0. [Operating Instructions]. Germany: VITA Zahnfabrik H. Rauter GmbH & Co.KG. 174. VITA Zahnfabrik. 2020a. VITA Toothguide 3D-MASTER. [Instruction for use]. Germany: VITA Zahnfabrik H. Rauter GmbH & Co.KG. 175. VITA. 2020b. VITA EasyShade Advance 4.0. [Online]. [3 September 2020]. Available from: https://www.vita-zahnfabrik.com/en/VITA-Easyshade-Advance-40-17073.html 176. Wang, F., Takahashi, H. and Iwasaki, N. 2013. Translucency of Dental Ceramics with Different Thickness. The Journal of Prosthetic Dentistry. 110(1), pp. 14-20. 177. Wee, A. G., Lindsey, D. T., Kuo, S. and Johnston, W.M. 2006. Color accuracy of commercial digital cameras for use in dentistry. Dental Materials. 22. pp. 553-559. 178. Westland, S., Luo, W., Li, Y., Pan, Q. and Joiner, A. 2017. Investigation of the perceptual thresholds of tooth whiteness. Journal of Dentistry. 67, pp. S11-S14. 179. Westland, S., Ripamonti, C. and Cheung, V. 2012. Computational Colour Science using MATLAB. West Sussex: John Wiley & Sons, Ltd. 180. Wyszecki, G. and Stiles, W.S. 1967. Color Science Concept and Methods, Quantitative Data and Formulas. 1st ed. New York: John Wiley & Sons, Inc. 181. X-rite. 2021.962/964 Spectrophotometer Operator’s Manual. [Instruction Manual]. Michigan, United States: X-Rite, Inc. 182. Xiao, J., Zhou, X., Zhu, W., Zhang, B., Li, J. and Xu, X. 2007. The prevalence of tooth discolouration and the self-satisfaction with tooth colour in a Chinese urban population. Journal of Oral Rehabilitation. 34(5), pp. 351–360. 183. Yamanel, K., Caglar, A., Özcan, M., Gulsah, K. and Bagis, B. 2010. Assessment of Color Parameters of Composite Resin Shade Guides Using Digital Imaging versus Colorimeter. Journal of Esthetic and Restorative Dentistry. 22(6), 379–388. 184. Yu, B., Ahn, J. and Lee, Y. 2009. Measurement of translucency of tooth enamel and dentin. Acta Odontologica Scandinavica. 67, pp. 57-64. 185. Yuan, J.C., Brewer, J.D., Monaco, E.A. and Davis, E.L. 2007. Defining a natural tooth color space based on a 3-dimensional shade system. Journal of Prosthetic Dentistry. 98, pp. 110–119. 186. Zenthöfer, A., Cabrera, T., Corcodel, N., Rammelsberg, P. and Hassel, A.J. 2014. Comparison of the Easyshade compact and advance in vitro and in vivo. Clinical Oral Investigations. 18(5), pp.1473-1479 187. Zhang, B., Nie, W. and Zhao, S. 2018. A novel Color Rendition Chart for digital tongue image calibration. Color Research and Application. 43, pp. 749-759. 188. Zhang, X., Wang, Q., Li, J., Zhou, X., Yang, Y. and Xu, H. 2017. Estimating spectral reflectance from camera responses based on CIE XYZ tristimulus values under multi‐illuminants. Color Research and Application. 42(1), 68–77."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/30951/1/Sullivan_Thesis.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Individuals desire to seek aesthetic dental treatments such as restoration, dental fillings, and whitening treatments to obtain the ‘perfect’ smile has given rise to research to determine the most accurate method for tooth colour measurement. Accurate tooth colour measurement is essential in producing satisfactory results for restoration and fillings, improving communication between dentist and patient, as well as determining the efficacy of tooth whitening products. Currently there is no ‘gold’ standard method for assessing tooth colour. Gloss, curvature, small size, in vivo location and translucency are attributes of teeth which make accurate colour measurement difficult. The aim of this thesis is to evaluate ‘accuracy’ of tooth colour measurement by exploring some of the issues arising in visual perception, indices, and instrumental colour measurement. A yellowness index (YIO) is developed to assess changes in perceptual yellowness instead of whiteness which highlighted issues in indices and perceptual evaluation. The amount of edge-loss that occurs in the spectrophotometer, spectroradiometer, Vita EasyShade and digital camera was assessed to determine the amount of error produced by each measurement device. A novel approach to the assessment of accuracy is introduced whereby accuracy is expressed by the instrument’s ability to ‘agree’ with visual perception, with perceptual responses as the ‘reference’. Statistical analysis methods r2, percent wrong decisions and STRESS analysis are used in order to assess the correlation between instrumental measurement and visual perception responses (Z-scores). It was found that there is no ‘gold’ standard instrument, but there are indices that produce better correlation between instrumental measurement and visual perception. WIO and YIO produced the best results for the assessment in changes in tooth whiteness and tooth yellowness no matter which instrument was used. The Vita Easy Shade was found to perform poorly in comparison to all other instruments."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Investigation into the relationship between visual perception and instrumental colour measurement of teeth"]}]}],"canonical_facts":{"dc:contributor.advisor":["Westland, Stephen","Xiao, Kiada"],"dc:contributor.sponsor":["Colgate-Palmolive"],"dc:creator":["Sullivan, Chelsea Rose"],"dc:date":["2022-01"],"dc:date.issued":["2022-01"],"dc:description.abstract":["Individuals desire to seek aesthetic dental treatments such as restoration, dental fillings, and whitening treatments to obtain the ‘perfect’ smile has given rise to research to determine the most accurate method for tooth colour measurement. Accurate tooth colour measurement is essential in producing satisfactory results for restoration and fillings, improving communication between dentist and patient, as well as determining the efficacy of tooth whitening products. Currently there is no ‘gold’ standard method for assessing tooth colour. Gloss, curvature, small size, in vivo location and translucency are attributes of teeth which make accurate colour measurement difficult. The aim of this thesis is to evaluate ‘accuracy’ of tooth colour measurement by exploring some of the issues arising in visual perception, indices, and instrumental colour measurement. A yellowness index (YIO) is developed to assess changes in perceptual yellowness instead of whiteness which highlighted issues in indices and perceptual evaluation. The amount of edge-loss that occurs in the spectrophotometer, spectroradiometer, Vita EasyShade and digital camera was assessed to determine the amount of error produced by each measurement device. A novel approach to the assessment of accuracy is introduced whereby accuracy is expressed by the instrument’s ability to ‘agree’ with visual perception, with perceptual responses as the ‘reference’. Statistical analysis methods r2, percent wrong decisions and STRESS analysis are used in order to assess the correlation between instrumental measurement and visual perception responses (Z-scores). It was found that there is no ‘gold’ standard instrument, but there are indices that produce better correlation between instrumental measurement and visual perception. WIO and YIO produced the best results for the assessment in changes in tooth whiteness and tooth yellowness no matter which instrument was used. The Vita Easy Shade was found to perform poorly in comparison to all other instruments."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/30951/1/Sullivan_Thesis.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Faculty of Arts, Humanities and Cultures (Leeds)","School of Design (Leeds)","Centre for Colour Design and Technology (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/30951/"],"dc:relation.references":["1. Abdi, H. and Williams, L.J. 2010. Principal Component Analysis. WIREs Computational Statistics. 2, pp.433-459. 2. Ahmad, I. 2006. Protocols for Predictable Aesthetic Dental Restorations. Oxford: Blackwell Munksgaard. 3. Ahn, J. and Lee, Y. 2008. Color distribution of shade guides in the value, chroma, and hue scale. The Journal of Prosthetic Dentistry. 100(1), pp. 18-28. 4. Al-Azzawi, A. 2007. Light and optics: principles and practices . Boca Raton, Florida: CRC/Taylor & Francis. 5. Al-Zarea, B. K. 2013. Satisfaction with Appearance and the Desired Treatment to Improve Aesthetics. International Journal of Dentistry. 2013, pp. 1-7. 6. Alkhatib, M. N., Holt, R. and Bedi, R. 2005. Age and perception of dental appearance and tooth colour. Gerodontology. 22, pp. 32-36. 7. Alqahtani, M. Q. 2014. Tooth-bleaching procedures and their controversial effects: A literature Review. The Saudi Dental Journal. 26, pp. 33-46. 8. ASTM E1164-12. 2017. ASTM E1164-12(2017):Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation. West Conshohocken, PA: ASTM International. 9. ASTM E1347-06. 2020. ASTM E1347-06: Standard Test Method for Color and Color-Difference Measurement by Tristimulus Colorimetry. West Conshohocken, PA: ASTM International. 10. ASTM E1349-06. 2018. ASTM E1349-06(2018): Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Bidirectional (45°:0° or 0°:45°) Geometry. West Conshohocken, PA: ASTM International. 11. ASTM E179-17. 2017. ASTM E179-17: Standard Guide for Selection of Geometric Conditions for Measurement of Reflection and Transmission Properties of Materials. West Conshohocken, PA: ASTM International. 12. ASTM E2466-13. 2013. ASTM E2466-13: Standard Test Method for Colorimetry of Teeth Using Digital Still Camera Technology. West Conshohocken, PA: ASTM International. 13. ASTM E2545-07. 2007. ASTM E2545-07: Standard Test Method for Objective Measurement of Gingival Color Using Digital Still Cameras. West Conshohocken, PA: ASTM International. 14. ASTM E308-18. 2001. ASTM E308-18: Standard Practice for Computing the Colors of Objects by Using the CIE System. West Conshohocken, PA: ASTM International. 15. ASTM E313-05. 2005. ASTM E313-05:Standard Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color Coordinates. E313-05. West Conshohocken, PA: ASTM International. 16. ASTM G138-12. 2012. ASTM G138-12: Standard Test Method for Calibration of a Spectroradiometer Using a Standard Source of Irradiance. West Conshohocken, PA: ASTM International. 17. Bahannan, S.A. 2014. Shade matching quality among dental students using visual and instrumental methods. Journal of Dentistry. 42, pp. 48-52. 18. Baltzer, A. and Kaufmann-Jinoian, V. 2004. The Determination Of The Tooth Colors. Quintessenz Zahntechnik.30(7), pp. 726-740. 19. Beltrami, R., Colombo, M., Chiesa, M., Bianchi, S. and Poggio, C. 2014. Scattering properties of a composite resin: Influence on color perception. Contemporary clinical dentistry, 5(4), pp.501–506. 20. Bengel, W. 2002. Mastering Dental Photography. Berlin, Germany: Quintessenz Verlags-GmbH. 21. Billmeyer, F.W. and Saltzman, M. 1981. Principles of color technology. 2nd ed. New York: Wiley. 22. Blair, J.J. 1985. Dental Restoration Shading. EP0154137 A1. 1985-09-11. 23. Blum, S., Horn, M. and Olms, C. 2018. A comparison of intraoral spectrophotometers—Are there user‐specific differences? Journal of Esthetic and Restorative Dentistry. 30(5), pp. 442–448. 24. Bolt, R. A., Ten Bosch, J. J. and Coops, J. C. 1994. Influence of window size in small-window colour measurement, particularly of teeth. Physics in Medicine and Biology. 39, pp. 1133-1142. 25. Bona, A. D., Barrett, A. A., Rosa, V. and Pinzetta, C. 2009. Visual and instrumental agreement in dental shade selection: Three distinct observer populations and shade matching protocols. Dental Materials. 25, pp. 276-281. 26. Brandt, J., Nelson, S., Lauer, H., von Hehn, U. and Brandt, S. 2017. In vivo study for tooth colour determination—visual versus digital. Clinical Oral Investigations, 21(9), pp. 2863–2871. 27. Brannan, D., Esplen, M. and Gray, J. 2011. Geometry. 2nd ed. Cambridge: Cambridge University Press. 28. Brook, A. H., Smith, R. M. and Lath, D. J. 2007. The clinical measurement of tooth colour and stain. International Dental Journal. 57, pp. 324-330. 29. Burkinshaw, S. 2004. Colour in relation to dentistry. Fundamentals of colour science. British Dental Journal. 196(1), pp. 33–41. 30. Cal, E., Sonugelen, M., Guneri, P., Kesercioglu, A. and Kose, T. 2004. Application of a digital technique in evaluating the reliability of shade guides. Journal of Oral Rehabilitation. 31(5), pp. 483–491. 31. Carey, C. 2014. Tooth Whitening: What we now know. Journal of evidence-based dental practice special issue -annual report on dental hygiene. 14(1), pp. 70-76. 32. Cho, B., Lim, Y. and Lee, Y. 2007. Comparison of the color of natural teeth measured by a colorimeter and Shade Vision System. Dental Materials. 23(10), pp. 1307–1312. 33. Chu, S.J. 2007. Range And Mean Distribution Frequency Of Individual Tooth Width Of The Maxillary Anterior Dentition. Practical Procedures In Aesthetic Dentistry. 19(4), Pp. 209-215. 34. Chu, S.J. and Okubo, S. 2008. Range and mean discordance of individual tooth width of the mandibular anterior dentition. Practical Procedures in Aesthetic Dentistry. 20(5), pp. 313-320. 35. Chu, S.J., Trushkowsky, R.D. and Paravina, R.D.. 2010. Dental color matching instruments and systems: review of clinical and research aspects. Journal of dentistry. 38s, pp. E2-e16. 36. Church, T., Jessup, J.P., Guillory, V.L and Vandewalle, K.S. 2017. Translucency and strength of high-translucency monolithic zirconium oxide materials. General Dentistry. (398), pp. 48-52. 37. CIE 15. 2004. CIE 15: Colorimetry Technical Report. Commission Interntionale de l’Eclairage. Vienna, Austria: CIE Central Bureau. 38. CIE 217. 2016. CIE 217: Recommended Method for Evaluating the Performance of Colour-Difference Formulae Technical Report. Commission Interntionale de l’Eclairage. Vienna, Austria: CIE Central Bureau. 39. Clarke, F. J. and Parry, D. 1985. Helmholtz Reciprocity: Its validity and application to reflectometry. Lighting Research & Technology (1969). 17(1), 1–11. 40. Colgate-Palmolive Company. 2021. Optic White Renewal Toothpaste. [Online]. [7 July 2021]. Available from: https://www.colgate.com/en-us/products/toothpaste/ow-renewal 41. Collins, L.Z., Naeeni, M., and Platten, S.M. 2008. Instant tooth whitening from a silica toothpaste containing blue covarine. Journal of Dentistry. 36s, pp. S21-S25. 42. Curd, F.M., Jasinevicius, T.R., Graves, A., and Cox, V. 2006. Comparison of the shade matching ability of dental students using two light sources. Journal of Prosthetic Dentistry. 96(6), pp. 391-396. 43. Da Silva, J. D., Park, S. E., Weber, H. and Ishikawa-Nagai, S. 2008. Clinical Performance of a newly developed spectrophotometric system on tooth colour reproduction. The Journal of Prosthetic Dentistry. 99(5). pp. 361-368. 44. De Bragança, R.M., Moraes, R.R. and Faria-e-Silva, A.L. 2021. Color assessment of resin composite by using cellphone images compared with a spectrophotometer. Restorative Dentistry & Endodontics. 46, pp. e23. 45. del Mar Pérez, M., Ghinea, R., Rivas, M.J., Yebra, A., Ionescu, A.M., Paravina, R.D. and Herrera, L.J. 2016. Development of a customized whiteness index for dentistry based on CIELAB colour space. Dental Materials. 32, pp. 461-467. 46. Ebner, M. ed. 2007. Color Constancy. West Sussex: John Wiley & Sons, Ltd. 47. Elamin, H.O., Abubakr, N.H. and Ibrahim, Y.E. 2015. Identifying the tooth shade in group of patients using Vita EasyShade. European Journal of Dentistry. 9(2), pp. 213-217. 48. Finlayson, G., and Zhu, Y. 2019. Finding a Colour Filter to Make a Camera Colorimetric by Optimisation. In: Computational Color Imaging, 27-29 March 2019, Japan. Switzerland: Springer International Publishing, pp. 53-62. 49. Flucke, J. 2021. The Future of Teeth Whitening. Dental Products Report. 55(10), pp. 22-23. 50. García, P.A., Huertas, R., Melgosa, M. and Cui, G. 2007. Measurement of the relationship between perceived and computed color difference. Journal of the Optical Science of America A. 24(7), pp. 1823-1829. 51. German, D.S., Chu, S.J., Fulong, M.L. and Patel, A. 2016. Simplifying optimal tooth-size calculations and communications between practitioners. American Journal of Orthodontics and Dentofacial Orthopedics. 150(6), pp. 1051-1055. 52. Gevaux, L., Simonot, L., Clerc, R., Gerardin, M. and Hebert, M. 2020. Evaluating edge loss in the reflectance measurement of translucent materials. Applied Optics. Optical Technology and Biomedical Optics. 59(28), pp. 8939–8950. 53. Gómez-Polo, C., Gómez-Polo, M., Celemin-Viñuela, A. and Martínez Vázquez De Parga, J. 2014. Differences between the human eye and the spectrophotometer in the shade matching of tooth colour. Journal of Dentistry. 42(6), pp. 742–745. 54. Gómez-Polo, C., Muñoz, M.P., Lorenzo Luengo, M.C., Vicente, P., Galindo, P. and Martín Casado, A.M. 2015. Comparison of the CIELab and CIEDE2000 color difference formulas. Journal of Prosthetic Dentistry. 115(1), pp. 65-70. 55. Gozalo-Diaz, D.J., Lindsey, D.T., Johnston, W.M. and Wee, A.G. 2007. Measurement of color for craniofacial structures using a 45/0-degree optical configuration. Journal of Prosthetic Dentistry. 97(1), pp.45-53. 56. Grand View Research. 2021. Oral Care Market Size, Share and Trends Report. [Online]. Market Analysis Report: Grand View Research. [Accessed 31 October 2021]. Available from: https://www.grandviewresearch.com/industry-analysis/oral-care-market 57. Guan, Y. H., Lath, D. L., Lilley, T. H., Willmot, D. R., Marlow., I. and Brook, A.H. 2005. The measurement of tooth whiteness by image analysis spectrophotometry: a comparison. Journal of Oral Rehabilitation. 32, pp. 7-15. 58. Gupte, V.C. 2010. Expressing colours numerically. In: Gulrajani, M. L., Colour measurement Principles, advances and industrial applications. Oxford: Woodhead Publishing Limited. 59. Hammad, I. A. 2003. Intrarater repeatability of shade selections with two shade guides. The Journal of Prosthetic Dentistry. 89(1), pp. 50-53. 60. He, L. and Nahar, V. 2016. Reuse of scientific data in academic publications: An investigation of Dryad Digital Repository. Aslib Journal of Information Management. 68(4), pp. 478–494. 61. He, W., Park, C., Byun, S., Tan, D., Lin, C. and Chee, W. 2020. Evaluating the relationship between tooth color and enamel thickness, using twin flash photography, cross‐polarization photography, and spectrophotometer. Journal of Esthetic and Restorative Dentistry. 32(1), pp. 91–101. 62. Hess, A.S. and Hess, J.R. 2018. Principal Component Analysis. Transfusion. 58, pp.1580-1582. 63. Hirschen, R. 2010. Visual and Instrumental Evaluation of whiteness and yellowness. In: Gulrajani, M. L., Colour measurement Principles, advances and industrial applications. Oxford: Woodhead Publishing Limited. 64. Höfel, L, Lange, M. and Jacobsen, T. 2007. Beauty and the teeth: perception of tooth color and its influence on the overall judgment of facial attractiveness. The International Journal of Periodontics & Restorative Dentistry. 27(4), pp. 349–357. 65. Hogan, R. 2021. Email Response to Chelsea Sullivan, 29 January 2021. 66. Howitt, D. and Cramer, D. 2014. Introduction to Statistics in Psychology. 6th ed. Harlow, England: Pearson. 67. Hughes, G. 2017. Sharing research data. Emergency Medicine Australasia. 29, pp. 4-5. 68. Hunt, R.W.G and Pointer, M.R. 2011. Measuring Colour. 4th Ed. West Sussex: John Wiley & Songs, Ltd. 69. Hunter, R. S. 1981. Conversion of Visual to Instrumental Measurement of Yellowness. Journal of the American Oil Chemists’ Society. 59(5), pp. 608-612 70. Jarad, F., Russell, M. and Moss, B. 2005. The use of digital imaging for colour matching and communication in restorative dentistry. British Dental Journal. 199(1), pp. 43–49. 71. Jeng, Y., Lin, T., Hsu, H., Chang, H. and Shieh, D. 2011. Human enamel rod presents anisotropic nanotribiological properties. Journal of the mechanical behavior of biomedical materials. 4, pp. 515-522. 72. Johnston, W. M. 2009. Color measurement in dentistry. Journal of Dentistry. 37s, pp. e2-e6. 73. Johnston, W.M., Hesse, N.S., Davis, B.K. and Seghi, R.R. 1996. Analysis of Edge-losses in Reflectance Measurements of Pigmented Maxillofacial Elastomer. Journal of Dental Research. 75(2), pp. 752-760. 74. Joiner, A. 2004. Tooth Colour: A Review Of The Literature. Journal Of Dentistry. 32, pp. 3-12 75. Joiner, A. 2010. Whitening toothpastes: A review of the literature. Journal of Dentistry. 38s, pp. e17-e24. 76. Joiner, A. and Luo, W. 2017. Tooth colour and whiteness: A review. Journal of Dentistry. 67, pp. S3-S10. 77. Joiner, A., Hopkinson, I., Deng, Y. and Westland, S. 2008a. A review of tooth colour and whiteness. Journal of Dentistry. 36s, pp. S2-S7. 78. Joiner, A., Philpotts, C.J., Alonso, C., Ashcroft, A.T. and Sygrove, N J. 2008b. A novel optical approach to achieving tooth whitening. Journal of dentistry. 36, pp. 8-14. 79. Kershaw, S., Newton, J. and Williams, D. 2008. The influence of tooth colour on the perceptions of personal characteristics among female dental patients: comparisons of unmodified, decayed and ‘whitened’ teeth. British Dental Journal. 204(E9). 80. Khashayar, G., Bain, P., Salari, S., Dozic, A., Kleverlaan, C. and Feilzer, A. 2014. Perceptibility and acceptability thresholds for colour differences in dentistry. Journal of Dentistry. 42(6), pp. 637–644. 81. Khashayar, G., Dozic, A., Kleverlaan, C.J. and Feilzer, A.J. 2012. Data comparison between two dental spectrophotometers. Operative Dentistry. 37(1), pp.12-20. 82. Khurana, R., Tredwin, C.J., Weisbloom, M. and Moles, D. R. 2007. A clinical evaluation of the individual repeatability of three commercially available colour measuring devices. British Dental Journal. 203(12), pp. 3-12. 83. Kim-Pusateri, S., Brewer J. D., Davis, E. L. and Wee, A. G. 2009. Reliability and Accuracy of four dental shade-matching devices. The Journal of Prosthetic Dentistry. 101(3), pp. 193-199. 84. Kim, J. Yu, B. and Lee, Y. 2008. Influence of surface layer removal of shade guide tabs on the measured color by spectrophotometer and spectroradiometer. Journal of Dentistry. 36, pp. 1061-1067. 85. Kim, M., Kim, B., Park, B., Lee, M., Won, Y., Kim, C. and Lee, S. 2018. A Digital Shade-Matching Device for Dental Color Determination Using the Support Vector Machine Algorithm. Sensors. 18(9), pp. 3051. 86. Kim, S.T., Abbott, P.V. and McGinley, P. 2000. The effects of Ledermix paste on discolouration of mature teeth. International Endodontic Journal. 33(3), 227–232. 87. Kim, Y., Son, H., Yi, K., Kim, H., Ahn, J. and Chang, J. 2013. The color change in artificial white spot lesions measured using a spectroradiometer. Clinical Oral Investigations. 17, pp. 139-146. 88. Kingdom, F.A.A. and Prins, N. 2010. Psychophysics: A Practical Introduction. London: Elsevier Ltd 89. Kirchner, E. and Dekker, N. 2011. Performance measures of color-difference equations: correlation coefficient versus standardized residual sum of squares. Journal of the Optical Science of America A. 28(9), pp. 1841-1848. 90. Klotz, A., Habibi, Y., Corcodel, N., Rammelsberg, P., Hassel, A.J. and Zenthöfer, A. 2018. Laboratory and clinical reliability of two spectrophotometers. Journal of Esthetic and Restorative Dentistry. Pp., 1-5. 91. Knight, R.D. 2008. Physics for Scientists and Engineers: A strategic Approach. 2nd ed. Upper Saddle River, NJ: Pearson. 92. Konica Minolta Sensing Americas Inc., 2020. Color Measurement Instrument Geometries. Konica Minolta Sensing America. [Online]. [Accessed 10 August 2020]. Available from: https://sensing.konicaminolta.us/us/blog/color-measurement-instrument-geometries/ 93. Konica Minolta. 2007. Spectroradiometer CS-2000/CS-2000A. [Instruction Manual]. United States: Konica Minolta, Inc. 94. Konica Minolta. 2014. Spectrophotometer CM-2600d/2500d. [Instruction Manual]. Japan: Konica Minolta, Inc. 95. Konica Minolta. 2015. Precise color communication; color control from perception to instrumentation. [Booklet]. Japan: Konica Minolta, Inc. 96. Konica Minolta. 2016a. Spectrophotometer CM-25cG. [Instruction Manual]. United Kingdom: Konica Minolta, Inc. 97. Konica Minolta. 2016b. Spectrophotometer CM-M6. [Instruction Manual]. United States: Konica Minolta, Inc. 98. Konica Minolta. 2019. Specular Component Included (SCI) vs. Specular Component Excluded (SCE). 24 January. Colour Measurement. [Online]. [Accessed 27 July 2020]. Available from: https://sensing.konicaminolta.asia/specular-component-included-sci-vs-specular-component-excluded-sce/ 99. Koumpia, E., Athanasiou, A.E., Eliades, T. and Knösel, M. 2018. Precision of a reflectance spectrophotometer in measuring anterior tooth colour. The Open Dental Journal. 12, pp. 884-895. 100. Kovacevic Pavicic, D., Pavlic, A., Kinkela Devcic, M., Lajnert, V. and Spalj, S. 2017. Tooth Color as a Predictor of Oral Health‐Related Quality of Life in Young Adults. Journal of Prosthodontics. 28(4), pp. e886–e892. 101. Kruskal, J.B. 1964. Multidimensional scaling by optimizing goodness of fit to a nonmetric hypothesis. Pychometrika. 29, pp. 1–27. 102. Kuehni, R. G. 2003. Color Space and Its Divisions: Color Order from Antiquity to the present. Hoboken, New Jersey: John Wiley & Sons Inc. 103. Langlais, R.P., Miller, C.S. and Nield-gehrig, J.S. 2009. Color Atlas of Common Oral Diseases. 4th ed. Philadelphia, PA: Lippincott Williams & Wilkins. 104. Lasseree, J., Pop-Ciutrila, I. and Colosi, H. 2011. A comparison between a new visual method of colour matching by intraoral camera and conventional visual and spectrometric methods. Journal of Dentistry. 39s, pp. e29-e36. 105. Lee, Y. and Powers, J.M. 2005. Comparison of CIE Lab, CIEDE 2000, and DIN 99 Color Differences Between Various Shade of Resin Composites. The International Journal of Prosthodontics. 18(2), pp. 150-155. 106. Lee, Y.K., Lim, B.S., and Kim, C.W. 2004. Influence of illuminating and viewing aperture size on the color of dental resin composites. Dental Materials. 20(2), pp. 116–123. 107. Lee, Y.K., Yu, B., Lim, J. I. and Lim, H. 2011. Perceived color shift of a shade guide according to the change of illuminant. The Journal of Prosthetic Dentistry. 105(2), pp. 91-99. 108. Lehmann, K.M., Igiel, C., Schmidtmann, I. and Scheller, H. 2010. Four color-measuring devices compared with a spectrophotometric reference system. Journal of Dentistry. 38s, pp. e65-e70. 109. Lim, H., Yu, B., Lim, J. and Lee, Y. 2010. Correlations between spectroradiometric and spectrophotometric colors of all-ceramic materials. Dental Materials. 26(11), pp. 1052–1058. 110. Luo, M., Cui, G. and Rigg, B. 2001. The development of the CIE 2000 colour-difference formula: CIEDE2000. Color Research and Application. 26(5), pp 340–350. 111. Luo, R. M. 2011. The quality of light sources. Coloration Technology. 127, pp. 85-87. 112. Luo, W., Naeeni, M., Platten, S., Wang, J., Sun, J.N., Westland, S. and Joiner, A. 2017. The in vitro and in vivo reproducibility of video-based digital imaging system for tooth colour measurement. Journal of Dentistry. 67, pp. S15-S19. 113. Luo, W., Westland, S., Brunton, P., Ellwood, R., Pretty, I. A. and Mohan, N. 2007. Comparison of the ability of different colour indices to assess changes in tooth whiteness. Journal of Dentistry. 35, pp. 109-116. 114. Luo, W., Westland, S., Ellwood, R., Pretty, I. and Cheung, V. 2009. Development of a whiteness index for dentistry. Journal of Dentistry. 37s, pp. e21-e26. 115. MacAdam, D.L. 1942. Visual Sensitivity to Color Differences in Daylight. Journal of the Optical Socieiety of America. 32(5), pp. 247-274. 116. MacDonald, R. 1980. Industrial pass/fail color matching. Part I. Preparation of visual color-matching data. Journal of Society of Dyers and Colorists. 96, Pp. 372–376. 117. Mackie, I.C. and Blinkhorn, A. 1995. Oral Health Prevention of Dental Disease. Manchester, United Kingdom: Oral Health and Development University Dental Hospital of Manchester. 118. Mahn, E., Tortora, S., Olate, B., Cacciuttolo, F., Kernitsky, J., and Jorquera, G. 2021. Comparison of visual analog shade matching, a digital visual method with a cross-polarized light filter, and a spectrophotometer for dental color matching. The Journal of Prosthetic Dentistry. 125(3), pp. 511–516. 119. Malacara, D. 2002. Color Vision and Colorimetry: theory and applications. Washington: SPIE Press. 120. Marques Junior, R.B., Baroudi, K., Campos dos Santos, A.F., Pontes, D. and Amaral, M. 2021. Tooth Discoloration Using Calcium Silicate-Based Cements For Simulated Revascularization in Vitro. Brazilian Dental Journal. 32(1), pp. 53-58. 121. Martínez-Verdú, F., Chorro, E., Parales, E., Vilaseca, M. and Pujol, J. 2010. Camera-based colour measurement. In: Gulrajani, M. L., Colour measurement Principles, advances and industrial applications. Oxford: Woodhead Publishing Limited. 122. Mazur, M., Westland, S., Jedliński, M., Maruotti, A., Nardi, G., Ottolenghi, L. and Guerra, F. 2020. The Influence of Dental Occlusion on Spectrophotometric Tooth Color Determinations. The Open Dentistry Journal. 14, pp. 247-254. 123. McDonald, R. 1997. Colour Physics for Industry. 2nd ed. Bradford: Society of Dyers and Colourists. 124. McLaren, K. 1970. Colour Passing - Visual or Instrumental. Journal of Society of Dyers and Colourists. 86(9), pp. 389-392 125. Melgosa, M., Alman, D., Grosman, M., Gómez-Robledo, L., Trémeau, A., Cui, G., García, P., Vázquez, D., Li, C. and Luo, M. 2013. Practical demonstration of the CIEDE2000 corrections to CIELAB using a small set of sample pairs. Color Research and Application. 38(6), 429–436. 126. Melgosa, M., Huertas, R. and Berns, R.S. 2008. Performance of recent advanced color-difference formulas using the standardized residual sum of squares index. Journal of the Optical Science of America A. 25(7), pp. 1828-1834. 127. Mello, M.M., Lieou, V. and Goodman, S.N. 2018. Clinical Trial Participants’ Views of the Risks and Benefits of Data Sharing. The New England Journal of Medicine. 378, pp. 2202-2211. 128. Mishchenko, M.I., Travis, L.D. and Lacis, A.A. 2002. Scattering, absorption, and emission of light by small particles. Bambridge: Cambridge University Press. 129. Mohan, N., Westland, S., Brunton, P., Ellwood, R., Pretty, I.A. and Wen, L. 2008. A clinical study to evaluate the efficacy of a novel tray based tooth whitening system. Journal of Dentistry. 26, pp. 21-26. 130. Montero, J., Gomez-Polo, C., Santos, J. A., Portillo, M., Lorenzo, M. C. and Albaladejo, A. 2014. Contributions of dental color to the physical attractiveness stereotype. Journal of Oral Rehabilitation. 41, pp. 768-782. 131. Nassau, K. 1998. Color for science, art and technology. Amsterdam, Netherlands: Elsevier. 132. National Library of Medicine. 2021. Data Reuse. [Online]. [Accessed 1 February 2021]. Available from: https://nnlm.gov/data/thesaurus/data-reuse 133. Nedelcu, R., Olsson, P., Nyström, I., Rydén, J. and Thor, A. 2018. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method. Journal of Dentistry. 69, pp. 110-118. 134. O’Brien, W.J., Groh, C.L. and Boenke, K.M. 1990. A new, small-color-difference equation for dental shades. Journal of Dental Research. 69(11), pp. 1762-1764. 135. Odioso L.L., Gibb, R.D. and Gerlach, R.W. 2000. Impact of demographic, behavioural, and dental care utilization parameters on tooth color and personal satisfaction. Compendium of Continuing Education in Dentistry. 21(29), pp. S35—S41. 136. Oguro, R., Nakajima, M., Seki, N., Sadr, A., Tagami, J. and Sumi, Y. 2016. The role of enamel thickness and refractive index on human tooth colour. Journal of Dentistry. 51, pp. 36-44. 137. Oleari, C. 2016. Standard Colorimetry: Definitions, Algorithms and Sotware. United Kingdom: John Wiley & Sons, Ltd. 138. Oliveira, D., Ayres, A., Rocha, M., Giannini, M., Puppin Rontani, R., Ferracane, J. and Sinhoreti, M. 2015. Effect of Different In Vitro Aging Methods on Color Stability of a Dental Resin‐Based Composite Using CIELAB and CIEDE2000 Color‐Difference Formulas. Journal of Esthetic and Restorative Dentistry. 27(5), pp. 322–330 139. Palumbo, P.A. and Weber, W.L. 1999. Novel spectrophotometer for the measurement of colour and appearance. Analytica Chimica Acta. 380(2), 243-261. 140. Pan, Q. and Westland, S. 2018. Tooth colour and whitening – digital technologies. Journal of Dentistry. 74(1), pp. S42-S46. 141. Pan, Q., Westland, S. and Ellwood, R. 2018. Evaluation of colorimetric indices for the assessment of tooth whiteness. Journal of Dentistry. 76, pp. 132-136. 142. Parameswaran, V., Anilkumar, S., Lylajam, S., Rajesh, C. and Narayan, V. 2016. Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems. The Journal of Indian Prosthodontic Society. 16(4), pp. 352–358. 143. Paravina, R. D. 2008. New Shade Guide for Tooth Whitening Monitoring: Visual Assessment. The Journal of Prosthetic Dentistry. 99(3), pp. 178-184. 144. Paravina, R., Ghinea, R., Herrera, L., Bona, A., Igiel, C., Linninger, M., Sakai, M., Takahashi, H., Tashkandi, E. and Del Mar Perez, M. 2015. Color Difference Thresholds in Dentistry: Color Difference Thresholds. Journal of Esthetic and Restorative Dentistry. 27, pp. S1–S9. 145. Paravina, R.D. and Powers, J. 2004. Esthetic color training in dentistry. St. Louise, MO: Elsevier Mosby. 146. Paravina, R.D., Aleksić, A., Tango, R.N., García-Beltrán, Johnston, W.M. and Ghinea, R.I. 2021. Harmonization of color measurements in dentistry. Measurement. 169, pp. 108504 147. Paravina, R.D., O’Keefe, K.L. and Kuljic, B.L. 2006. Color of permanent teeth: a prospective clinical study. Balkan Journal of Stomatology. 10, pp. 93–97. 148. Pasquetto, I.V., Sands, A.E. and Borgman, C. L. 2015. Exploring Openness in Data and Science: What is “Open,” to Whom, When, and Why?. Proceedings of the Association for Information Science and Technology. 52(1), pp. 1-2. 149. Paul, S., Peter, A., Pietrobon, N. and Hämmerle, C. 2002. Visual and Spectrophotometric Shade Analysis of Human Teeth. Journal of Dental Research. 81(8), pp. 578–582. 150. Pérez, M., Ghinea, R., Rivas, M.J., Yebra, A., Ionescu, A.M., Paravina, R.D. and Herrera, L.J. 2016. Development of a customized whiteness index for dentistry based on CIELAB colour space. Dental Materials. 32, pp. 461-467. 151. Piwowar, H.A. and Vision, T.J. 2013. Data reuse and the open data citation advantage. PeerJ. 1, pp. e175. 152. Pop-Ciutrila, I. S., Ghinea, R., Colori, H. A. and Dunea, D. 2016. Dentin translucency and color evaluation in human incisors, canines, and molars. Journal of Prosthetic Dentistry. 115(4), pp. 475-481. 153. Purdue, 2015. F Critical Values Table. [Online]. [Accessed 20 September 2018]. Available from: https://www.stat.purdue.edu/~jtroisi/STAT350Spring2015/tables/FTable.pdf 154. Rasmussen, C.M. 2019. Market Analysis 2020 on 26th World Congress on Dentistry and Oral Health. Journal of Oral Medicine. 3(5). 155. Rauf, W. 2020. Email response to Chelsea Sullivan, 20 July 2020. 156. Rubio, L., Sioli, J.M., Suarez, J., Gaitan, M. J. and Martin-de-las-Heras, S. 2015. Spectrophotometric analysis of color changes in teeth incinerated at increasing temperatures. Forensic Science International. 252, pp. 193.e1–193.e6. 157. Schmidseder, J. 2000. Aesthetic Denistry. New York: Thieme Stuttgart. 158. Seghi, R.R. 1990. Effects of Instrument-measuring geometry on Colorimetric Assessments of Dental Porcelains. Journal of Dental Restorations. 69(5), pp. 1180-1183. 159. Sindi, K.H., Bubb, N.L., Gutteridge, D.L. and Evans, J.A. 2015. In vitro enamel thickness measurements with ultrasound. Ultrasound in Medicine and Biology. 41(1), pp. 301-308. 160. Stratview Research, 2020. Global Teeth Whitening Products Market, Dynamics, and Market Analysis. Radian Offshore Consultanacy LLP. 161. Sullivan, C., Pan, Q., Westland, S. and Ellwood, R. 2019. A yellowness index for use in dentistry. Journal of Dentistry. 91, pp. 103244. 162. Tao, D., Smith, R.N., Zhang, Q., Sun, J.N., Philpotts, C.J., Ricketts, S.R., Naeeni, M. and Joiner, A. 2017a. Tooth whitening evaluation of blue covarine containing toothpastes. Journal of Dentistry. 67, pp. S20-S24. 163. Tao, D., Sun, J.N., Wang, X., Zhang, Q., Naeeni, M.A., Phipotts, C.J. and Joiner, A. 2017b. In vitro and clinical evaluation of optical tooth whitening toothpastes. Journal of Dentistry. 67, pp. S25–S28. 164. Ten Bosch J.J. and Coops J.C. 1995. Tooth color and reflectance as related to light scattering and enamel hardness. Journal of Dental Research. 74(1), pp. 74-80. 165. Thurstone, L.L. 1927. Psychophysical Analysis. The American Journal of Psychology. 38(3), pp. 368-389. 166. Tin-Oo, M., Saddki, N. and Hassan, N. 2011. Factors influencing patient satisfaction with dental appearance and treatments they desire to improve aesthetics. BMC Oral Health. 11(6). 167. Tsukida, K. and Gupta, M.R. 2011. How to Analyze Paired Comparison Data. UWEETR-2011-0004 Electrical Engineering. May 2011, University of Washington Department of Electrical Engineering. 168. Tung, F. F., Goldstein, G. R., Jang, S. and Hittelman, E. 2002. The repeatability of an intraoral dental colorimeter. The Journal of Prosthetic Dentistry. 88(6), pp. 585-590. 169. Vallittu, P. K., Vallittu, A. S. and Lassila, V. P. 1996. Dental aesthetics – a survey of attitudes in different groups of patients. Journal of Dentistry. 24(5), pp. 335-338. 170. VeriVide. 2008. Powerful, fast and flexible colour management: DigiEye can evaluate objects previously considered unmeasurable. [Leaflet]. Leicester: Verivide. 171. VeriVide. 2020. DigiEye System: Non-contact digital colour measurement and imaging system. [Product Specification Leaflet]. Leicester, United Kingdom: VeriVide. 172. VITA North America. 2022. VITA classical Shade Guide. [Online]. [Accessed 22 May 2022]. Available from: https://www2.vitanorthamerica.com/products/shade-management/vita-classical-previously-the-lumin-vacuum-shade-guide/ 173. VITA Zahnfabrik. 2013. VITA Easyshade Advance 4.0. [Operating Instructions]. Germany: VITA Zahnfabrik H. Rauter GmbH & Co.KG. 174. VITA Zahnfabrik. 2020a. VITA Toothguide 3D-MASTER. [Instruction for use]. Germany: VITA Zahnfabrik H. Rauter GmbH & Co.KG. 175. VITA. 2020b. VITA EasyShade Advance 4.0. [Online]. [3 September 2020]. Available from: https://www.vita-zahnfabrik.com/en/VITA-Easyshade-Advance-40-17073.html 176. Wang, F., Takahashi, H. and Iwasaki, N. 2013. Translucency of Dental Ceramics with Different Thickness. The Journal of Prosthetic Dentistry. 110(1), pp. 14-20. 177. Wee, A. G., Lindsey, D. T., Kuo, S. and Johnston, W.M. 2006. Color accuracy of commercial digital cameras for use in dentistry. Dental Materials. 22. pp. 553-559. 178. Westland, S., Luo, W., Li, Y., Pan, Q. and Joiner, A. 2017. Investigation of the perceptual thresholds of tooth whiteness. Journal of Dentistry. 67, pp. S11-S14. 179. Westland, S., Ripamonti, C. and Cheung, V. 2012. Computational Colour Science using MATLAB. West Sussex: John Wiley & Sons, Ltd. 180. Wyszecki, G. and Stiles, W.S. 1967. Color Science Concept and Methods, Quantitative Data and Formulas. 1st ed. New York: John Wiley & Sons, Inc. 181. X-rite. 2021.962/964 Spectrophotometer Operator’s Manual. [Instruction Manual]. Michigan, United States: X-Rite, Inc. 182. Xiao, J., Zhou, X., Zhu, W., Zhang, B., Li, J. and Xu, X. 2007. The prevalence of tooth discolouration and the self-satisfaction with tooth colour in a Chinese urban population. Journal of Oral Rehabilitation. 34(5), pp. 351–360. 183. Yamanel, K., Caglar, A., Özcan, M., Gulsah, K. and Bagis, B. 2010. Assessment of Color Parameters of Composite Resin Shade Guides Using Digital Imaging versus Colorimeter. Journal of Esthetic and Restorative Dentistry. 22(6), 379–388. 184. Yu, B., Ahn, J. and Lee, Y. 2009. Measurement of translucency of tooth enamel and dentin. Acta Odontologica Scandinavica. 67, pp. 57-64. 185. Yuan, J.C., Brewer, J.D., Monaco, E.A. and Davis, E.L. 2007. Defining a natural tooth color space based on a 3-dimensional shade system. Journal of Prosthetic Dentistry. 98, pp. 110–119. 186. Zenthöfer, A., Cabrera, T., Corcodel, N., Rammelsberg, P. and Hassel, A.J. 2014. Comparison of the Easyshade compact and advance in vitro and in vivo. Clinical Oral Investigations. 18(5), pp.1473-1479 187. Zhang, B., Nie, W. and Zhao, S. 2018. A novel Color Rendition Chart for digital tongue image calibration. Color Research and Application. 43, pp. 749-759. 188. Zhang, X., Wang, Q., Li, J., Zhou, X., Yang, Y. and Xu, H. 2017. Estimating spectral reflectance from camera responses based on CIE XYZ tristimulus values under multi‐illuminants. Color Research and Application. 42(1), 68–77."],"dcterms:accessrights":["public"],"dc:title":["Investigation into the relationship between visual perception and instrumental colour measurement of teeth"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000265811395"]},"updated_at":"2026-11-18T23:18:31Z"}