{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:30957"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:30957","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Factors that affect the relationship between microorganisms in the air and on surfaces in hospital environments","abstract":"Hospital acquired infections (HAIs) incur mortalities and high costs for treatment including the ongoing outbreak of the COVID-19 pandemic as a result of contaminated air and surfaces. Understanding the relationship between microorganisms in the air and on surfaces and assessing how hospital environment factors affect this relationship is essential to mitigate the infection risk. A systematic review and meta-analysis showed that there were positive correlations between the airborne bacteria measured as aerobic colony count (ACC) and indoor air quality (IAQ) parameters in the hospital. Also, previous mathematical approaches to correlating air and surface microorganisms were identified and evaluated against published data. Environmental sampling was carried out to explore the transient relationships between air and surface bioburden in a hospital. The average concentration of ACC in air was 196±103 cfu.m-3, while our multi-regression model recommended a maximum of 118 cfu.m-3. High touch surfaces in 1-bed, 4-bed, and 10-bed rooms, found 100%, 84%, and 73% surface deposition samples within an accepted level of concentration (<2.5 cfu.cm-2). The loss rate due to deposition onto surfaces (λ_d) was 7.2±2.88h-1 for ACC and 4.32±2.88h-1 for Staphylococcus spp. The effect of ventilation and spatial location on (λ_d) was investigated by developing and validating a novel Automated Multiplate Passive Air Sampling (AMPAS) device. Increasing the ventilation rate from 3 to 6 ACH results in a reduction of Staphylococcus aureus load in air and on surfaces by 45%±10% and 44%±32%, respectively and λ_d was 1.38±0.48h-1 in the chamber. The relationship between microorganisms in the air and on surfaces is a significant parameter in an infection risk model. It can be represented by λ_d, however this is complex to determine in a dynamic environment. The findings support the importance of controlling the ventilation and the environmental parameters to mitigate both air and surface infection risks in the hospital environment.","abstract_html":"Hospital acquired infections (HAIs) incur mortalities and high costs for treatment including the ongoing outbreak of the COVID-19 pandemic as a result of contaminated air and surfaces. Understanding the relationship between microorganisms in the air and on surfaces and assessing how hospital environment factors affect this relationship is essential to mitigate the infection risk. A systematic review and meta-analysis showed that there were positive correlations between the airborne bacteria measured as aerobic colony count (ACC) and indoor air quality (IAQ) parameters in the hospital. Also, previous mathematical approaches to correlating air and surface microorganisms were identified and evaluated against published data. Environmental sampling was carried out to explore the transient relationships between air and surface bioburden in a hospital. The average concentration of ACC in air was 196±103 cfu.m-3, while our multi-regression model recommended a maximum of 118 cfu.m-3. High touch surfaces in 1-bed, 4-bed, and 10-bed rooms, found 100%, 84%, and 73% surface deposition samples within an accepted level of concentration (&lt;2.5 cfu.cm-2). The loss rate due to deposition onto surfaces (λ_d) was 7.2±2.88h-1 for ACC and 4.32±2.88h-1 for Staphylococcus spp. The effect of ventilation and spatial location on (λ_d) was investigated by developing and validating a novel Automated Multiplate Passive Air Sampling (AMPAS) device. Increasing the ventilation rate from 3 to 6 ACH results in a reduction of Staphylococcus aureus load in air and on surfaces by 45%±10% and 44%±32%, respectively and λ_d was 1.38±0.48h-1 in the chamber. The relationship between microorganisms in the air and on surfaces is a significant parameter in an infection risk model. It can be represented by λ_d, however this is complex to determine in a dynamic environment. The findings support the importance of controlling the ventilation and the environmental parameters to mitigate both air and surface infection risks in the hospital environment.","abstract_has_math":false,"creators":["Hiwar, Waseem Faeq Mohammed"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Noakes, Catherine","Fletcher, Louise"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-11","date_published":"2021-11","updated_at":"2026-11-18T23:18:31Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.858650"],"render_values":[{"text":"uk.bl.ethos.858650","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["1955605"],"render_values":[{"text":"1955605","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000337423456"],"render_values":[{"text":"0000-0003-3742-3456","href":"https://orcid.org/0000-0003-3742-3456","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/30957/1/Hiwar_Waseem_Civil%20Engineering_PhD_2022.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A30957","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Noakes, Catherine","Fletcher, Louise"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC"]},{"key":"dc:creator","label":"Author","values":["Hiwar, Waseem Faeq Mohammed"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000337423456"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-11"]},{"key":"dc:date.issued","label":"Date","values":["2021-11"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Civil Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/30957/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Adams, C.E. and Dancer, S.J. 2020. Dynamic transmission of Staphylococcus aureus in the intensive care unit. International Journal of Environmental Research and Public Health. 17(6), p.2109. Al-Shahwani, M.F. 2005. Bacterial distribution analysis of the atmosphere of two hospitals in lbb, Yemen. Eastern Mediterranean Health Journal. 11(5–6), pp.1115–1119. Alberti, C., Bouakline, A., Ribaud, P., Lacroix, C., Rousselot, P., Leblanc, T. and Derouin, F. 2001. Relationship between environmental fungal contamination and the incidence of invasive aspergillosis in haematology patients. Journal of Hospital Infection. 48(3), pp.198–206. AMS 2021. Winter viruses and COVID-19 could push NHS to breaking point, warns new report | The Academy of Medical Sciences. The academy of medical sciences. Andersen, B.M., Rasch, M., Kvist, J., Tollefsen, T., Lukkassen, R., Sandvik, L. and Welo, A. 2009. Floor cleaning: effect on bacteria and organic materials in hospital rooms. Journal of Hospital Infection. 71(1), pp.57–65. Ao, J., Hao, Z., Zhu, H., Wen, L. and Yang, R. 2014. Environmental Investigations and Molecular Typing of Aspergillus in a Chinese Hospital. Mycopathologia. 177, pp.51–57. Arcy, N.D., Cloutman-green, E., Klein, N. and Spratt, D.A. 2014. American Journal of Infection Control Environmental viral contamination in a pediatric hospital outpatient waiting area : Implications for infection control. American Journal of Infection Control. 42(8), pp.856–860. Arnow, P.M., Sadigh, M., Costas, C., Weil, D. and Chudy, R. 1991. Endemic and epidemic aspergillosis associated with in-hospital replication of Aspergillus organisms. Journal of Infectious Diseases. 164(5), pp.998–1002. Asadi, S., Wexler, A.S., Cappa, C.D., Barreda, S., Bouvier, N.M. and Ristenpart, W.D. 2019. Aerosol emission and superemission during human speech increase with voice loudness. Nature/cientific Reports. Atkinson, J., Chartier, Y., Pessoa-Silva, C.L., Jensen, P., Li, Y. and Seto, W.-H. 2009. Basic concept of ventilation flow rate. Augustowska, M. and Dutkiewicz, J. 2006. Variability of airborne microflora in a hospital ward within a period of one year. Annals of Agricultural and Environmental Medicine. 13(1), pp.99–106. Azimi, F., Naddafi, K., Nabizadeh, R., Hassanvand, M.S., Alimohammadi, M., Afhami, S. and Musavi, S.N. 2013. Fungal air quality in hospital rooms: A case study in Tehran, Iran. Journal of Environmental Health Science and Engineering. 11(1), pp.2–5. Barbolla, R.E., Centrón, D., Maimone, S., Rospide, F., Salgueira, C., Altclas, J. and Catalano, M. 2008. Molecular epidemiology of Acinetobacter baumannii spread in an adult intensive care unit under an endemic setting. American Journal of Infection Control. 36(6), pp.444–452. Barbut, F., Yezli, S., Mimoun, M., Pham, J., Chaouat, M. and Otter, J.A. 2013. Reducing the spread of Acinetobacter baumannii and methicillin-resistant Staphylococcus aureus on a burns unit through the intervention of an infection control bundle. Burns. 39(3), pp.395–403. Barnes, R.A. and Rogers, T.R. 1989. Control of an outbreak of nosocomial aspergillosis by laminar air-flow isolation. Journal of Hospital Infection. 14(2), pp.89–94. Bartlett, M.S., Vermund, S.H., Jacobs, R., Durant, P.J., Shaw, M.M., Smith, J.W., Tang, X., Lu, J.J., Li, B., Jin, S. and Lee, C.H. 1997. Detection of Pneumocystis carinii DNA in air samples: Likely environmental risk to susceptible persons. Journal of Clinical Microbiology. 35(10), pp.2511–2513. Beato Arribas, B., McDonagh, A., Noakes, C. and Sleigh, P. 2015. Assessing the near patient infection risk in isolation rooms. Healthy Buildings-Conference proceedings. Beggs, C.B., Noakes, C.J., Sleigh, P.A., Fletcher, L.A. and Kerr, K.G. 2006. Methodology for determining the susceptibility of airborne microorganisms to irradiation by an upper-room UVGI system. Journal of Aerosol Science. 37(7), pp.885–902. Best, E.L., Fawley, W.N., Parnell, P. and Wilcox, M.H. 2010. The Potential for Airborne Dispersal of Clostridium difficile from Symptomatic Patients. Clinical Infectious Diseases. 50(11), pp.1450–1457. Best, E.L.L., Sandoe, J.A.T. and Wilcox, M.H.H. 2012. Potential for aerosolization of Clostridium difficile after flushing toilets: The role of toilet lids in reducing environmental contamination risk. Journal of Hospital Infection. 80(1), pp.1–5. Bischoff, W.E., Mcnall, R.J., Blevins, M.W., Turner, J.L., Lopareva, E.N., Rota, P.A. and Stehle, J.R. 2016. Detection of measles virus RNA in air and surface specimens in a hospital setting. Journal of Infectious Diseases. 213(4), pp.600–603. Bodey, G.P. and Johnston, D. 1971. Microbiological evaluation of protected environments during patient occupancy. Applied microbiology. 22(5), pp.828–836. Bogusz, A., Stewart, M., Hunter, J., Yip, B., Reid, D., Robertson, C. and Dancer, S.J. 2013. How quickly do hospital surfaces become contaminated after detergent cleaning? Healthcare Infection. 18(1), pp.3–9. Bonnal, C., Leleu, C., Brugière, O., Chochillon, C., Porcher, R., Boelle, P.-Y., Menotti, J., Houze, S., Lucet, J.-C. and Derouin, F. 2015. Relationship between Fungal Colonisation of the Respiratory Tract in Lung Transplant Recipients and Fungal Contamination of the Hospital Environment. PLoS ONE. (6), pp.1–11. Booth, T.F., Kournikakis, B., Bastien, N., Ho, J., et al. 2005. Detection of Airborne Severe Acute Respiratory Syndrome (SARS) Coronavirus and Environmental Contamination in SARS Outbreak Units. The Journal of Infectious Diseases. 191(9), pp.1472–1477. Božić, J., Ilić, P. and Ilić, S. 2019. Indoor air quality in the hospital: The influence of heating, ventilating and conditioning systems. Brazilian Archives of Biology and Technology. 62. Brun, C.P., Miron, D., Silla, L.M.R. and Pasqualotto, A.C. 2013. Fungal spore concentrations in two haematopoietic stem cell transplantation (HSCT) units containing distinct air control systems. Epidemiology and Infection. 141(4), pp.875–879. Brunetti, L., Santoro, E., Cavallo, P., Boccia, G., Motta, O. and Capunzo, M. 2006. Two-years surveillance of fungal contamination in three hospital departments in Campania Region. Journal of Preventive Medicine and Hygiene. 47(1), pp.22–25. Cantium Scientific Limited 2018. Bioaerosol Sampler Operating Manual MicroBio MB2 Bioaerosol Sampler Operating Manual. April. Carducci, A., Verani, M., Lombardi, R., Casini, B. and Privitera, G. 2011. Environmental survey to assess viral contamination of air and surfaces in hospital settings. Journal of Hospital Infection. 77(3), pp.242–247. Carvalho, K.S., Melo, M.C., Melo, G.B. and Gontijo-Filho, P.P. 2007. Hospital surface contamination in wards occupied by patients infected with MRSA or MSSA in a Brazilian university hospital. Journal of Basic and Applied Pharmaceutical Sciences. 28(2), pp.159–163. Cavallo, M., Andreoni, S., Martinotti, M.G., Rinaldi, M. and Fracchia, L. 2013. Monitoring Environmental Aspergillus spp. Contamination and Meteorological Factors in a Haematological Unit. Mycopathologia. 176(5–6), pp.387–394. Centers for Disease Control and Prevention 2003. Guidelines for Environmental Infection Control in Health-Care Facilities.Recommendations from CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC). american society for healthcare engineering/American hospital association. (2003), pp.1–48. Chakrabarti, A., Nayak, N., Kumar, P.S., Talwar, P., Chari, P.S. and Panigrahi, D. 1992. Surveillance of Nosocomial Fungal Infections in a Burn Care Unit. Infection. 20(3), pp.132–135. Cheng, V.C.C., Chen, J.H.K., Wong, S.C.Y., Leung, S.S.M., So, S.Y.C., Lung, D.C., Lee, W.M., Trendell-Smith, N.J., Chan, W.M., Ng, D., To, L., Lie, A.K.W. and Yuen, K.Y. 2015. Hospital Outbreak of Pulmonary and Cutaneous Zygomycosis due to Contaminated Linen Items from Substandard Laundry. Clinical Infectious Diseases. 62(6), pp.714–721. Chughtai, A.A., Stelzer-Braid, S., Rawlinson, W., Pontivivo, G., Wang, Q., Pan, Y., Zhang, D., Zhang, Y., Li, L. and MacIntyre, C.R. 2019. Contamination by respiratory viruses on outer surface of medical masks used by hospital healthcare workers. BMC Infectious Diseases. 19(1). Computing, I.P. 2020. Lab: Controlling a Stepper Motor With an H-Bridge. Available from: https://itp.nyu.edu/physcomp/labs/motors-and-transistors/lab-controlling-a-stepper-motor-with-an-h-bridge/. Cordeiro, R.A., Brilhante, R.S.N., Pantoja, L.D.M., Moreira Filho, R.E., Vieira, P.R.N., Rocha, M.F.G., Monteiro, A.J. and Sidrim, J.J.C. 2010. Isolation of pathogenic yeasts in the air from hospital environments in the city of Fortaleza, northeast Brazil. Brazilian Journal of Infectious Diseases. 14(1), pp.30–34. Creamer, E., Shore, A.C., Deasy, E.C., Galvin, S., Dolan, A., Walley, N., Mchugh, S., Fitzgerald-hughes, D., Sullivan, D.J., Cunney, R., Coleman, D.C. and Humphreys, H. 2014. Air and surface contamination patterns of meticillin-resistant Staphylococcus aureus on eight acute hospital wards. Journal of Hospital Infection. 86(3), pp.201–208. Crimi, P., Argellati, F., Macrina, G., Tinteri, C., Copello, L., Rebora, D., Romania, L. and Rizzetto, R. 2006. Microbiological surveillance of hospital ventilation systems in departments at high risk of nosocomial infections. Journal of Preventive Medicine and Hygiene. 47(3), pp.105–109. Crimi, P., Valgiusti, M., Macrina, G., Grieco, A., Massone, L., Ciucci, A., Ansaldi, F., Sticchi, L., Sasso, L., Del Buono, S. and Durando, P. 2009. Evaluation of microbial contamination of air in two haematology departments equipped with ventilation systems with different filtration devices. Journal of Preventive Medicine and Hygiene. 50(1), pp.33–36. Cundell, A.M. 2018. Microbial Ecology of the Human Skin. Microbial Ecology. 76(1), pp.113–120. Dancer, S.J. 2014. Controlling hospital-acquired infection: Focus on the role of the environment and new technologies for decontamination. Clinical Microbiology Reviews. 27(4), pp.665–690. Dancer, S.J. 2004. How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals. Journal of Hospital Infection. 56(1), pp.10–15. Dancer, S.J. 2009. The role of environmental cleaning in the control of hospital-acquired infection. Journal of Hospital Infection. 73(4), pp.378–385. Dancer, S.J., White, L. and Robertson, C. 2008. Monitoring environmental cleanliness on two surgical wards. International Journal of Environmental Health Research. 18(5), pp.357–364. Demirel, R., Sen, B., Kadaifciler, D., et al., 2017. Indoor airborne fungal pollution in newborn units in Turkey. Environmental Monitoring and Assessment. 189(7). Department of Health 2007. Heating and ventilation systems Health Technical Memorandum Specialised ventilation for healthcare premises. Department of Health / Estates and Facilities Division 2007. Health Technical Memorandum 03-01: Specialised ventilation for healthcare premises. Part A - Design and installation. Döring, G., Hörz, M., Ortelt, J., Grupp, H. and Wolz, C. 1993. Molecular epidemiology of Pseudomonas aeruginosa in an intensive care unit. Epidemiology & Infection. 110(3), pp.427–436. Dougall, L.R., Booth, M.G., Khoo, E., Hood, H., MacGregor, S.J., Anderson, J.G., Timoshkin, I. V. and Maclean, M. 2019. Continuous monitoring of aerial bioburden within intensive care isolation rooms and identification of high-risk activities. Journal of Hospital Infection. 103(2), pp.185–192. Eadie, E., Fletcher, L., Tidswell, E., Mahoney, P.O., Welch, D., Adamson, C.S., Brenner, D.J. and Noakes, C. 2021. Far-UVC efficiently inactivates an airborne pathogen in a room- sized chamber. Research Square. (preprint), pp.1–13. Ehrlich, R., Miller, S. and Walker, R.L. 1970. Relationship Between Atmospheric Temperature and Survival of Airborne Bacteria. Ensor, E., Humphreys, H., Peckham, D., Webster, C. and Knox, A.J. 1996. Is Burkholderia (Pseudomonas) cepacia disseminated from cystic fibrosis patients during physiotherapy? Journal of Hospital Infection. 32(1), pp.9–15. European Committee 2009. EU Guidelines to Good Manufacturing Practice Medicinal Products for Human and Veterinary Use. Handbook of Pharmaceutical Manufacturing Formulations. 2008 (March 2010), pp.79–92. Faires, M.C., Pearl, D.L., Ciccotelli, W.A., Straus, K., Zinken, G., Berke, O., Reid-Smith, R.J. and Weese, J.S. 2012. A prospective study to examine the epidemiology of methicillin-resistant Staphylococcus aureus and Clostridium difficile contamination in the general environment of three community hospitals in southern Ontario, Canada. BMC Infectious Diseases. 12, pp.1–14. Falvey, D.G. and Streifel, A.J. 2007. Ten-year air sample analysis of Aspergillus prevalence in a university hospital. Journal of Hospital Infection. 67(1), pp.35–41. Farmaki, E., Panagopoulou, P., Filioti, J., Farmaki, E. and Maloukou, A. 2007. Filamentous Fungi in a Tertiary Care Hospital : Environmental Surveillance and Susceptibility to Antifungal Drugs. Infection Control & Hospital Epidemiology. 28(1), pp.60–67. La Fauci, V., Genovese, C., Facciolà, A., Palamara, M.A.R. and Squeri, R. 2017. Five-year microbiological monitoring of wards and operating theatres in southern Italy. Journal of Preventive Medicine and Hygiene. 58(2), pp.166–172. Fawcett, T. 2006. An introduction to ROC analysis. Pattern Recognition Letters. 27(8), pp.861–874. Fekadu, S. and Getachewu, B. 2015. Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital. Ethiopian journal of health sciences. 25(2), pp.117–122. Field, A.P. 2003. The Problems in Using Fixed-Effects Models of Meta-Analysis on Real-World Data. Understanding Statistics. 2(2), pp.105–124. Fifield, L.J., Lomas, K.J., Giridharan, R. and Allinson, D. 2018. Hospital wards and modular construction: Summertime overheating and energy efficiency. Building and Environment. 141, pp.28–44. Friberg, B., Friberg, S. and Burman, L.G. 1999. Correlation between surface and air counts of particles carrying aerobic bacteria in operating rooms with turbulent ventilation: An experimental study. Journal of Hospital Infection. 42(1), pp.61–68. Fuchs, N.A. 1986. Methods for determining aerosol concentration. Aerosol Science and Technology. 5(2), pp.123–143. Gammaitoni, L. and Nucci, M.C. 1997. Using a Mathematical Model to Evaluate the Efficacy of TB Control Measures. Emerging Infectious Diseases. 3(3), pp.335–342. Gaudart, J., Cloutman-green, E., Guillas, S., Arcy, N.D., Hartley, J.C., Gant, V. and Klein, N. 2013. Healthcare Environments and Spatial Variability of Healthcare Associated Infection Risk : Cross-Sectional Surveys. PLoS ONE. 8(9), pp.1–8. Gehanno, J.F., Louvel, A., Nouvellon, M. and Caillard, J. 2009. Aerial dispersal of meticillin-resistant Staphylococcus aureus in hospital rooms by infected or colonised patients. Journal of Hospital Infection. 71(3), pp.256–262. Gheith, S., Ranque, S., Bannour, W., Ben Youssef, Y., Khelif, A., Ben Said, M., Njah, M. and Saghrouni, F. 2015. Hospital environment fungal contamination and aspergillosis risk in acute leukaemia patients in Sousse (Tunisia). mycoses. 58, pp.337–342. Gizaw, Z., Gebrehiwot, M. and Yenew, C. 2016. High bacterial load of indoor air in hospital wards : the case of University of Gondar teaching hospital , Northwest Ethiopia. Multidisciplinary Respiratory Medicine., pp.1–7. Grieble, H.G., Colton, R., Bird, T.J., Toigo, A. and Griffith, L. 1970. Fine-particle humidifiers Source of Pseudomonas aeruginosa infections in a respiratory-Disease Unit. the New England Journal of Medicine. 282(10), pp.531–535. Griffith, C.J., Obee, P., Cooper, R.A., Burton, N.F. and Lewis, M. 2007. The effectiveness of existing and modified cleaning regimens in a Welsh hospital. Journal of Hospital Infection. 66(4), pp.352–359. Grover, W.H., Bryan, A.K., Diez-Silva, M., Suresh, S., Higgins, J.M. and Manalis, S.R. 2011. Measuring single-cell density. Proceedings of the National Academy of Sciences of the United States of America. 108(27), p.10992. Guest, J.F., Keating, T., Gould, D. and Wigglesworth, N. 2020. Modelling the annual NHS costs and outcomes attributable to healthcare-associated infections in England. BMJ Open. 10(1), pp.1–11. Gurgui, M., Sanchez, F., March, F., Lopez-contreras, J., Martino, R. and Cotura, A. 2011. Nosocomial outbreak of Blastoschizomyces capitatus associated with contaminated milk in a haematological unit. Journal of Hospital Infection. 78(4), pp.274–278. Haig, C.W., Mackay, W.G., Walker, J.T. and Williams, C. 2016. Bioaerosol sampling: Sampling mechanisms, bioefficiency and field studies. Journal of Hospital Infection. 93(3), pp.242–255. Hambraeus, A. 1988. Aerobiology in the operating room-a review. Journal of Hospital Infection. 11(SUPPL. A), pp.68–76. Hang, J., Li, Y. and Jin, R. 2014. The influence of human walking on the flow and airborne transmission in a six-bed isolation room: Tracer gas simulation. Building and Environment. 77, pp.119–134. Hardy, K.J., Gossain, S., Henderson, N., Drugan, C., Oppenheim, B.A., Gao, F. and Hawkey, P.M. 2007. Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour. Journal of Hospital Infection. 66(4), pp.360–368. Hathway, E.A. 2011. CFD Modelling of Pathogen Transport due to Human Activity. Hathway, E.A., Noakes, C.J., A., F.L., Sleigh, P.A., Clifton, I., W., E. and M. 2013. The Role of Nursing Activities on the Bioaerosol Production in Hospital Wards. Indoor and Built Environment. 22(2), pp.410–421. Hathway, E.A., Noakes, C.J., Sleigh, P.A. and Fletcher, L.A. 2011. CFD simulation of airborne pathogen transport due to human activities. Building and Environment. 46(12), pp.2500–2511. Hedges, L. V. 1982. Fitting Categorical Models to Effect Sizes from a Series of Experiments. Journal of Educational Statistics. 7(2), pp.119–137. Hiwar, W., King, M.F., Shuweihdi, F., Fletcher, L.A., Dancer, S.J. and Noakes, C.J. 2021. What is the relationship between indoor air quality parameters and airborne microorganisms in hospital environments? A systematic review and meta-analysis. Indoor Air. Hosmer, D. w and Lemeshow, S. 2003. Applied Logistic Regression. John Wiley & Sons. (3nd Edition). Hospenthal, D.R., Kwon-Chung, K.J. and Bennett, J.E. 1998. Concentrations of airborne Aspergillus compared to the incidence of invasive aspergillosis: Lack of correlation. Medical Mycology. 36(3), pp.165–168. Howard-Reed, C., Wallace, L. and Emmerich, S.J. 2003. Deposition rates of fine and course particles in residential buildings. Gaithersburg, MD. Available from: https://nvlpubs.nist.gov/nistpubs/Legacy/IR/nistir7068.pdf. Hsu, Y.C., Kung, P.Y., Wu, T.N. and Shen, Y.H. 2012. Characterization of indoor-air bioaerosols in Southern Taiwan. Aerosol and Air Quality Research. 12(4), pp.651–661. Hsueh, P.R., Huang, H.C., Young, T.G., Su, C.Y., Liu, C.S. and Yen, M.Y. 2014. Bacteria killing nanotechnology Bio-Kil effectively reduces bacterial burden in intensive care units. European Journal of Clinical Microbiology and Infectious Diseases. 33(4), pp.591–597. Huang, H.L., Lee, M.K. and Shih, H.W. 2017. Assessment of indoor Bioaerosols in public spaces by real-time measured airborne particles. Aerosol and Air Quality Research. 17(9), pp.2276–2288. Huang, P.Y., Shi, Z.Y., Chen, C.H., Den, W., Huang, H.M. and Tsai, J.J. 2013. Airborne and surface-bound microbial contamination in two intensive care units of a medical center in central Taiwan. Aerosol and Air Quality Research. 13(3), pp.1060–1069. Humphreys, H., Peckhams, D., Knox, A.J., Ensor, E. and Webster, C. 1996. Is Burkholderia disseminated ( Pseudomonas ) cepacia patients during from cystic fibrosis physiotherapy ? Journal of Hospital Infection. 32, pp.9–15. Hunter, J.E. and Schmidt, F.L. 2000. Fixed Effects vs. Random Effects Meta‐Analysis Models: Implications for Cumulative Research Knowledge. International Journal of Selection and Assessment. 8(4), pp.275–292. Jaffal, A.A., Nsanze, H., Bener, A., Ameen, A.S., Banat, I.M. and Mogheth, A.A. El 1997. HOSPITAL AIRBORNE MICROBIAL POLLUTION IN A DESERT COUNTRY. Environment international. 23(2), pp.167–172. Jomha, M.Y., Yusef, H. and Holail, H. 2014. Journal of Global Antimicrobial Resistance Antimicrobial and biocide resistance of bacteria in a Lebanese tertiary care hospital. Integrative Medicine Research. 2(4), pp.299–305. Khojasteh, V.J., Edwards-jones, V., Childs, C. and Foster, H.A. 2007. Prevalence of toxin producing strains of Staphylococcus aureus in a pediatric burns unit. Burns. 33, pp.334–340. Killingley, B., Greatorex, J., Digard, P.,et al., 2016. The environmental deposition of influenza virus from patients infected with influenza A(H1N1)pdm09: Implications for infection prevention and control. Journal of Infection and Public Health. 9(3), pp.278–288. Kim, K.H., Kabir, E. and Jahan, S.A. 2018. Airborne bioaerosols and their impact on human health. Journal of Environmental Sciences (China). 67, pp.23–35. Kim, S.H., Chang, S.Y., Sung, M., Park, J.H., Kim, H. Bin, Lee, H., Choi, J.P., Choi, W.S. and Min, J.Y. 2016a. Extensive Viable Middle East Respiratory Syndrome (MERS) Coronavirus Contamination in Air and Surrounding Environment in MERS Isolation Wards. Clinical Infectious Diseases. 63(3), pp.363–369. King, M.-F., Noakes, C.J., Sleigh, P.A., Bale, S. and Waters, L. 2016. Relationship between healthcare worker surface contacts, care type and hand hygiene: An observational study in a single-bed hospital ward. Journal of Hospital Infection. 94(1), pp.48–51. King, M.F., Camargo-Valero, M.A., Matamoros-Veloza, A., Sleigh, P.A. and Noakes, C.J. 2017a. An effective surrogate tracer technique for S. aureus bioaerosols in a mechanically ventilated hospital room replica using dilute aqueous lithium chloride. Atmosphere. 8(12), p.238. King, M.F., Noakes, C.J., Sleigh, P.A. and Camargo-Valero, M.A. 2013. Bioaerosol deposition in single and two-bed hospital rooms: A numerical and experimental study. Building and Environment. 59, pp.436–447. Krishna, B.V.S., Asha, B.P. and Chandrasekhar, M.R. 2007. Extended-spectrum β-lactamase producing Klebsiella pneumoniae in neonatal intensive care unit. Indian Journal of Pediatrics. 74(10), pp.627–630. Kronman, M.P., Baden, H.P., Jeffries, H.E., Heath, J., Cohen, G.A. and Zerr, D.M. 2007. An investigation of Aspergillus cardiac surgical site infections in 3 pediatric patients. American Journal of Infection Control. 35(5), pp.332–337. Lai, A.C.K. 2002. Particle deposition indoors: a review. Indoor Air. 12(4), pp.211–214. Lai, A.C.K., Wong, L.T., Mui, K.W., Chan, W.Y. and Yu, H.C. 2012. An experimental study of bioaerosol (1-10 μm) deposition in a ventilated chamber. Building and Environment. 56, pp.118–126. Lee, L.D., Berkheiser, M., Jiang, Y., Hackett, B., Hachem, R.Y., Chemaly, R.F. and Raad, I.I. 2007. Risk of Bioaerosol Contamination With Aspergillus Species Before and After Cleaning in Rooms Filtered With High-Efficiency Particulate Air Filters That House Patients With Hematologic Malignancy. Infection Control & Hospital Epidemiology. 28(09), pp.1066–1070. Lee, L.D., Hachem, R.Y., Ms, M.B., Hackett, B., Jiang, Y. and Raad, I.I. 2012. American Journal of Infection Control Hospital environment and invasive aspergillosis in patients with hematologic malignancy. American Journal of Infection Control. 40(3), pp.247–249. Lewis, S. and Clarke, M. 2001. Forest plots: Trying to see the wood and the trees. British Medical Journal. 322(7300), pp.1479–1480. Liberati, A., Altman, D.G., Tetzlaff, J., Mulrow, C., Gøtzsche, P.C., Ioannidis, J.P.A., Clarke, M., Devereaux, P.J., Kleijnen, J. and Moher, D. 2009. The PRISMA Statement for Reporting Systematic Reviews and Meta-Analyses of Studies That Evaluate Health Care Interventions : Explanation and Elaboration. plosmedicine. 6(7). Licina, D., Bhangar, S., Brooks, B., Baker, R., Firek, B., Tang, X., Morowitz, M.J., Banfield, J.F. and Nazaroff, W.W. 2016. Concentrations and sources of airborne particles in a neonatal intensive care unit. PLoS ONE. 11(5), pp.1–17. Liguori, G., Bagattini, M., Gallè, F., Negrone, M., Di Onofrio, V. and Triassi, M. 2010. Automated cleaning of fan coil units with a natural detergent-disinfectant product. Annals of Clinical Microbiology and Antimicrobials. 9, pp.8–12. Liu, Z., Zhuang, W., Hu, X., Zhao, Z., Rong, R., Ding, W., Li, J. and Li, N. 2020. Effect of equipment layout on bioaerosol temporal-spatial distribution and deposition in one BSL-3 laboratory. Building and Environment. 181(July). Lopez, G.U., Gerba, C.P., Tamimi, A.H., Kitajima, M., Maxwell, S.L. and Rose, J.B. 2013. Transfer efficiency of bacteria and viruses from porous and nonporous fomites to fingers under different relative humidity conditions. Applied and Environmental Microbiology. Loveday, H.P., Wilson, J.A., Pratt, R.J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J. and Wilcox, M. 2014. Epic3: National evidence-based guidelines for preventing healthcare-associated infections in nhs hospitals in england. Journal of Hospital Infection. 86(S1), pp.S1–S70. Marr, L.C., Tang, J.W., Van Mullekom, J. and Lakdawala, S.S. 2019. Mechanistic insights into the effect of humidity on airborne influenza virus survival, transmission and incidence. Journal of the Royal Society Interface. 16(150). Martínez-herrera, E.O., Frías-de-león, M.G., Duarte-escalante, E., Calderón-ezquerro, M.C., Jiménez-martínez, M.C., Acosta-altamirano, G., Rivera-becerril, F., Toriello, C. and Reyes-montes, M.R. 2016. Fungal diversity and Aspergillus in hospital environments. Annals of Agricultural and Environmental Medicine. 23(2), pp.264–269. Martins-diniz, J.N., Aparecida, R., Toscano, E. and José, M. 2005. Monitoring of airborne fungus and yeast species in a hospital unit. Rev Saude Publica. 39(3), pp.1–7. Martins-Diniz, J.N., da Silva, R.A.M., Miranda, E.T. and Mendes-Giannini, M.J.S. 2005. [Monitoring of airborne fungus and yeast species in a hospital unit]. Revista de saude publica. 39(3), pp.398–405. Matoušková, I. and Holy, O. 2014. Monitoring of the Environment at the Transplant Unit — Hemato-Oncology Clinic. International Journal of Environmental Research and Public Health. 11(4), pp.9480–9490. Mcdonagh, A., Noakes, C. and Fletcher, L.A. 2013. Experimentally Evaluating the Effectivness of an Upper- Room UVGI System In: 11 REHVA World Congress, Clima 2013- Energy efficient, smart and healthy buildins, 16-19 June 2013 McEldowney, S. and Fletcher, M. 1988. The effect of temperature and relative humidity on the survival of bacteria attached to dry solid surfaces. Letters in Applied Microbiology. 7(4), pp.83–86. McLarnon, N., Edwards, G., Burrow, J., MacLaren, W., Aidoo, K. and Hepher, M. 2006. The efficiency of an air filtration system in the hospital ward. International Journal of Environmental Health Research. 16(4), pp.313–317. Me´heust, D., Gangneux, J.P. and Le Cann, P. 2013. Comparative evaluation of three impactor samplers for measuring airborne bacteria and fungi concentrations. Journal of Occupational and Environmental Hygiene. 10(8), pp.455–459. Meakin, N.S., Bowman, C., Lewis, M.R. and Dancer, S.J. 2012. Comparison of cleaning efficacy between in-use disinfectant and electrolysed water in an English residential care home. Journal of Hospital Infection. 80(2), pp.122–127. Méheust, D., Le Cann, P. and Gangneux, J.P. 2013a. Rapid quantification of viable fungi in hospital environments: Analysis of air and surface samples using solid-phase cytometry. Journal of Hospital Infection. 83(2), pp.122–126. Méheust, D., Le Cann, P., Reboux, G., Millon, L. and Gangneux, J.P. 2014. Indoor fungal contamination: Health risks and measurement methods in hospitals, homes and workplaces. Critical Reviews in Microbiology. 40(3), pp.248–260. Memon, B., Bhutto, G. and Rizvi, W. 2016. Measurement of air contamination in different wards of public sector hospital , Sukkur. Pakistan Journal of Pharmaceutical Sciences. 29(6), pp.2015–2021. Miller, S.L., Nazaroff, W.W., Jimenez, J.L., Boerstra, A., Buonanno, G., Dancer, S.J., Kurnitski, J., Marr, L.C., Morawska, L. and Noakes, C. 2021. Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event. Indoor Air. 31(2), pp.314–323. Mingotti, N., Wood, R., Noakes, C. and Woods, A.W. 2020. The mixing of airborne contaminants by the repeated passage of people along a corridor. Journal of Fluid Mechanics. 903, p.52. Mirhoseini, S.H., Nikaeen, M., Khanahmad, H. and Hatamzadeh, M. 2015. Monitoring of airborne bacteria and aerosols in different wards of hospitals – Particle counting usefulness in investigation of airborne bacteria. Annals of Agricultural and Environmental Medicine. 22(4), pp.670–673. Moher, D., Liberati, A., Tetzlaff, J., Altman, D.G. and Group, T.P. 2009. Preferred Reporting Items for Systematic Reviews and Meta-Analyses : The PRISMA Statement. plosmedicine. 6(7). Montagna, M.T., De Giglio, O., Cristina, M.L., et al., 2017. Evaluation of Legionella air contamination in healthcare facilities by different sampling methods: An Italian multicenter study. International Journal of Environmental Research and Public Health. 14(7), p.670. Montagna, M.T., de Giglio, O., Napoli, C., Lovero, G., Caggiano, G., Delia, M., Pastore, D., Santoro, N. and Specchia, G. 2012. Invasive fungal infections in patients with hematologic malignancies (Aurora Project): Lights and shadows during 18-months surveillance. International Journal of Molecular Sciences. 13(1), pp.774–787. Moore, G., Ali, S., FitzGerald, G., Muzslay, M., Atkinson, S., Smith, S., Cryer, P., Gush, C. and Wilson, A.P.R. 2010. Ward assessment of SmartIdeas Project: Bringing source isolation to the patient. Journal of Hospital Infection. 76(2), pp.103–107. Moore, J.E., Mcllhatton, B., Buchanan, J., Gilpin, D., Shaw, A., Hall, V., Murphy, P.G. and Elborn, J.S. 2002. Occurrence of Burkholderia cepacia in the hospital environment. Irish Journal of Medical Science. 171(3), pp.131–133. Morawska, L., Tang, J.W., Bahnfleth, W., et al., 2020b. How can airborne transmission of COVID-19 indoors be minimised? Environment International. 142, p.105832. Møretrø, T., Heir, E., Mo, K.R., Habimana, O., Abdelgani, A. and Langsrud, S. 2010. Factors affecting survival of Shigatoxin-producing Escherichia coli on abiotic surfaces. International Journal of Food Microbiology. 138(1–2), pp.71–77. Mousavi, M.S., Hadei, M., Majlesi, M., Hopke, P.K., Yarahmadi, M., Emam, B., Kermani, M. and Shahsavani, A. 2019. Investigating the effect of several factors on concentrations of bioaerosols in a well-ventilated hospital environment. Environmental Monitoring and Assessment 2019 191:7. 191(7), pp.1–11. Munoz-Price, L.S., Fajardo-Aquino, Y., Arheart, K.L., Cleary, T., DePascale, D., Pizano, L., Namias, N., Rivera, J.I., O’Hara, J.A. and Doi, Y. 2013. Aerosolization of Acinetobacter baumannii in a trauma ICU. Critical Care Medicine. 41(8), pp.1915–1918. Muzslay, M., Moore, G., Turton, J.F. and Wilson, A.P. 2013a. Dissemination of antibiotic-resistant enterococci within the ward environment: The role of airborne bacteria and the risk posed by unrecognized carriers. American Journal of Infection Control. 41(1), pp.57–60. Nakagawa, S. and Cuthill, I.C. 2007. Effect size, confidence interval and statistical significance: A practical guide for biologists. Biological Reviews. 82(4), pp.591–605. Nandalal, P. and Somashekar, R.K. 2007. Prevalence of Staphylococcus aureus and Pseudomonas aeruginosa in indoor air flora of a district hospital , Mandya , Karnataka. journal of environmental biology. 28(2), pp.197–200. Napoli, C., Marcotrigiano, V. and Montagna, M.T. 2012. Air sampling procedures to evaluate microbial contamination: A comparison between active and passive methods in operating theatres. BMC Public Health. 12(1), p.1. Nazaroff, W.W. 2016. Indoor bioaerosol dynamics. Indoor Air. 26(1), pp.61–78. NHS 2021. Vaccinations in the UK | Coronavirus in the UK. GOV.UK. [Online]. [Accessed 1 October 2021]. Available from: https://coronavirus.data.gov.uk/details/cases. Niaré-Doumbo, S., Normand, A.C., Diallo, Y.L., Dembelé, A.K., Thera, M.A., Diallo, D., Piarroux, R., Doumbo, O. and Ranque, S. 2014. Preliminary Study of the Fungal Ecology at the Haematology and Medical-Oncology Ward in Bamako, Mali. Mycopathologia. 178(1–2), pp.103–109. Nielsen, P. V. 2009. Control of airborne infectious diseases in ventilated spaces. Journal of the Royal Society Interface. 6(SUPPL. 6). Noakes, C.J. and Andrew Sleigh, P. 2009. Mathematical models for assessing the role of airflow on the risk of airborne infection in hospital wards. Journal of the Royal Society Interface. 6(SUPPL. 6). Nunes, Z.G., Martins, A.S., Altoe, A.L.F., Nishikawa, M.M., Leite, M.O., Aguiar, P.F. and Fracalanzza, S.E.L. 2005. Indoor air microbiological evaluation of offices, hospitals, industries, and shopping centers. Memorias do Instituto Oswaldo Cruz. 100(4), pp.351–357. Omelyansky, V.. 1940. Manual in Microbiology. USSR Academy of Sciences, Moscow, Leningrad. Osman, M.E., Ibrahim, H.Y., Yousef, F.A., Elnasr, A.A., Saeed, Y. and Hameed, A.A. 2018. A study on microbiological contamination on air quality in hospitals in Egypt. Indoor and Built Environment. 27(7), pp.953–968. Panagea, S., Winstanley, C., Walshaw, M.J., Ledson, M.J. and Hart, C.A. 2005. Environmental contamination with an epidemic strain of Pseudomonas aeruginosa in a Liverpool cystic fibrosis centre , and study of its survival on dry surfaces. Journal of Hospital Infection. 59, pp.102–107. Panagopoulou, P., Filioti, J., Petrikkos, G., Giakouppi, P., Anatoliotaki, M., Farmaki, E., Kanta, A., Apostolakou, H., Avlami, A., Samonis, G. and Roilides, E. 2002. Environmental surveillance of filamentous fungi in three tertiary care hospitals in Greece. Journal of Hospital Infection. 52, pp.185–191. Pankhurst, L.J., Taylor, J., Cloutman-Green, E.A., Hartley, J.C. and Lai, K.M. 2011. Can Clean-Room Particle Counters be Used as an Infection Control Tool in Hospital Operating Theatres?: http://dx.doi.org/10.1177/1420326X11409467. 21(3), pp.381–391. Park, D.U., Yeom, J.K., Lee, W.J. and Lee, K.M. 2013. Assessment of the levels of airborne bacteria, gram-negative bacteria, and fungi in hospital lobbies. International Journal of Environmental Research and Public Health. 10(2), pp.541–555. Pasquarella, C., Pitzurra, O. and Savino, A. 2000. The index of microbial air contamination. Journal of Hospital Infection. 46(4), pp.241–256. Perdelli, F., Cristina, M.L., Sartini, M., Spagnolo, A.M., Dallera, M., Ottria, G., Lombardi, R., Grimaldi, M. and Orlando, P. 2006. Fungal Contamination in Hospital Environments. Infection Control & Hospital Epidemiology. 27(1), pp.44–47. Perdelli, F., Dallera, M., Cristina, M.L., Sartini, M., Ottria, G., Spagnolo, A.M. and Orlando, P. 2008. A new microbiological problem in intensive care units: Environmental contamination by MRSA with reduced susceptibility to glycopeptides. International Journal of Hygiene and Environmental Health. 211(1–2), pp.213–218. PHE and LSHTM 2021. The contribution of nosocomial infections to the first wave - 28 January 2021. https://www.gov.uk/government/publications/phe., p.12. Picot-Guéraud, R., Khouri, C., Brenier-Pinchart, M.P., Saviuc, P., Fares, A., Sellon, T., Thiebaut-Bertrand, A. and Mallaret, M.R. 2015. En-suite bathrooms in protected haematology wards: A source of filamentous fungal contamination? Journal of Hospital Infection. 91(3), pp.244–249. Pittet, D., Allegranzi, B., Sax H. and Dharan S. Pessoa-Silva CL. Donaldson L. Boyce JM. WHO Global Patient Safety Challenge, W.A. for P.S. 2006. Evidence-based model for hand transmission during patient care and the role of improved practices.[see comment]. The Lancet Infectious Diseases. 6(10), pp.641–652. Prevention, C. for D.C. and n.d. CDC - Hierarchy of Controls - NIOSH Workplace Safety and Health Topic. [Accessed 29 June 2018]. Available from: https://www.cdc.gov/niosh/topics/hierarchy/default.html. Quinn, J.P., Arnow, P.M., Weil, D. and Rosenbluth, J. 1984. Outbreak of JK Diphtheroid Infections Associated with Environmental Contamination. JOURNAL OF CLINICAL MICROBIOLOGY. 19(5), pp.668–671. Rainer, J., Peintner, U. and Pöder, R. 2001. Biodiversity and concentration of airborne fungi in a hospital environment. Mycopathologia. 149(2), pp.87–97. Rawlinson, S., Ciric, L. and Cloutman-Green, E. 2019. How to carry out microbiological sampling of healthcare environment surfaces? A review of current evidence. Journal of Hospital Infection. 103(4), pp.363–374. Ríos-Yuil, J.M., Arenas, R., Fernández, R., Calderón-Ezquerro, M. and Rodriguez-Badillo, R. 2012. Aeromycological study at the intensive care unit of the ‘Dr. Manuel Gea Gonzalez’ General Hospital. Brazilian Journal of Infectious Diseases. 16(5), pp.432–435. Roberts, K., Smith, C.F., Snelling, A.M., Kerr, K.G., Banfield, K.R., Sleigh, P.A. and Beggs, C.B. 2008. Aerial Dissemination of Clostridium difficile spores. BMC Infectious Diseases. 8(7), pp.1–6. Rodrigues, A.G. and Araujo, R. 2007. Comparison of Andersen and honey jar methods for monitoring hospital wards. Indoor and Built Environment. 16(1), pp.71–76. Rohrer, J.M. 2018. Thinking Clearly About Correlations and Causation: Graphical Causal Models for Observational Data. Advances in Methods and Practices in Psychological Science. 1(1), pp.27–42. Rosenbaum, P.R., Hedges, L. and Olkin, I. 1987. Statistical Methods for Meta-Analysis. Journal of the American Statistical Association. 82(397), p.350. Rostami, N., Alidadi, H., Zarrinfar, H. and Salehi, P. 2017. Assessment of indoor and outdoor airborne fungi in an Educational, Research and Treatment Center. Italian Journal of Medicine. 11(1), pp.52–56. Rudnick, S.N. and Milton, D.K. 2003. Risk of indoor airborne infection transmission estimated from carbon dioxide concentration. Indoor Air. 13(3), pp.237–245. Saadoun, I., Jaradat, Z.W., Ali, I., Tayyar, A., Nasser, Z. El and Ababneh, Q. 2015. I ndoor and Built Airborne methicillin-resistant Staphylococcus aureus in the indoor environment of King Abdullah University Hospital , Jordan. Indoor and Built Environment. 24(3), pp.315–323. Sabino, R., Ver, C., Parada, H., Viegas, C., Carolino, E., Clemons, K. V and Stevens, D.A. 2014. Molecular screening of 246 Portuguese Aspergillus isolates among different clinical and environmental sources. Medical Mycology. 52, pp.517–527. Saha, R., Agarawal, S. and Khan, A.M. 2017. Air sampling procedures to evaluate microbial contamination: A comparison between active and passive methods at high‑risk areas in a tertiary care hospital of Delhi. journal of patient safety & infection control. 5(1), pp.18–23. Sajjadi, S.A., Shakeri, H., Haghighi, M.H.M. and Mohammadzade, A. 2016. Microbial indoor air quality of public places in a semi-dry city in Iran. International Journal of Tropical Medicine. 11(4), pp.102–107. Sarfati, J., Traore, F., Camet, J.D., Derouin, F. and Latgej, J.P. 1994. Molecular Epidemiology of Nosocomial Invasive Aspergillosis. JOURNAL OF CLINICAL MICROBIOLOGY. 32(3), pp.684–690. Schmidt, E.A., Coleman, D.L. and Mallison, G.F. 1984. Improved system for floor cleaning in health care facilities. Applied and Environmental Microbiology. 47(5), pp.942–946. Setlhare, G., Malebo, N., Shale, K. and Lues, R. 2014. Identification of airborne microbiota in selected areas in a health-care setting in South Africa. BMC Microbiology. 14(1). Sexton, T., Clarke, P., O’Neill, E., Dillane, T. and Humphreys, H. 2006. Environmental reservoirs of methicillin-resistant Staphylococcus aureus in isolation rooms: Correlation with patient isolates and implications for hospital hygiene. Journal of Hospital Infection. 62(2), pp.187–194. Sheerin, M.P., Granzow, F.E., Anderson, D.J., Burley, B.J., Dombrowski, J.M., English, T.R., Erickson, D.S., Fauber, J.P., Flannery, J.J., Friedman, S.D., Hauck, D.J., Heinlein, R.N., Hosking, N., Johnson, A.L., Keen, M.R., Koenigshofer, D., Langowski, P.H., Locke, M.D., Mages, S.J., Mason, D.M., Mead, K.R., Moeller, R.D., Monroe, K.A., Ninomura, P.T., Olmsted, R.N., Stewart, E., Barnaby, C.S. and Humble, J. 2020. Ventilation of Health Care Facilities. ANSI/ASHRAE/ASHE Addendum p to ANSI/ASHRAE/ASHE Standard 170-2017. 8400. Shimono, N., Hayashi, J. and Matsumoto, H. 2012. Vigorous cleaning and adequate ventilation are necessary to control an outbreak in a neonatal intensive care unit. Journal of Infection and Chemotherapy. 18(3), pp.303–307. Shimose, L.A., Masuda, E., Sfeir, M., Berbel Caban, A., Bueno, M.X., Depascale, D., Spychala, C.N., Cleary, T., Namias, N., Kett, D.H., Doi, Y. and Munoz-Price, L.S. 2016. Carbapenem-Resistant Acinetobacter baumannii: Concomitant Contamination of Air and Environmental Surfaces. Infection Control and Hospital Epidemiology. 37(7), pp.777–781. Shiomori, T., Miyamoto, H., Makishima, K., Yoshida, M., Fujiyoshi, T., Udaka, T., Inaba, T. and Hiraki, N. 2002. Evaluation of bedmaking-related airborne and surface methicillin-resistant Staphylococcus aureus contamination. Journal of Hospital Infection. 50, pp.30–35. Shrestha, R., Shrestha, J.M. and Gurung, B. 2012. Antibiotic usage and its sensitivity pattern in the NICU. Kathmandu University Medical Journal. 10(38), pp.27–32. Smith, J., Adams, C.E., King, M.F., Noakes, C.J., Robertson, C. and Dancer, S.J. 2018a. Is there an association between airborne and surface microbes in the critical care environment? Journal of Hospital Infection. 100(3), pp.e123–e129. Stone, J.W. and Das, B.C. 1986. Investigation of an outbreak of infection with Acinetobacter calcoaceticus in a special care baby unit. Journal of Hospital Infection. 7(1), pp.42–48. Talon, D., Excoffon, L., Tiv, M., Pinçon, A.L., Gbaguidi-Haoré, H. and Bertrand, X. 2008. Environmental reservoirs of meticillin resistant Staphylococcus aureus in patients’ rooms: Potential impact on care practices. British Journal of Infection Control. 9(5), pp.10–14. Tambekar, D.H., Gulhane, P.B. and Bhokare, D.D. 2007. Studies on environmental monitoring of microbial air flora in the hospitals. Journal of Medical Sciences. 7(1), pp.67–73. Tang, J.W. 2009. The effect of environmental parameters on the survival of airborne infectious agents. Journal of the Royal Society Interface. 6(SUPPL. 6). Tang, J.W., Bahnfleth, W.P., Bluyssen, P.M., Buonanno, G., Jimenez, J.L., Kurnitski, J., Li, Y., Miller, S., Sekhar, C., Morawska, L., Marr, L.C., Melikov, A.K., Nazaroff, W.W., Nielsen, P. V., Tellier, R., Wargocki, P. and Dancer, S.J. 2021. Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Journal of Hospital Infection. 110, pp.89–96. Tang, J.W., Noakes, C.J., Nielsen, P. V., Eames, I., Nicolle, A., Li, Y. and Settles, G.S. 2011. Observing and quantifying airflows in the infection control of aerosol- and airborne-transmitted diseases: An overview of approaches. Journal of Hospital Infection. 77(3), pp.213–222. Tekİn, A., Dal, T., Selçuk, C.T. and Devecİ, Ö. 2013. Orthophenylphenol in healthcare environments : a trial related to a new administration method and a review of the literature *. Turkish Journal of Medical Sciences. 43(June 2011), pp.805–809. Textor, J., van der Zander, B., Gilthorpe, M.S., Liśkiewicz, M. and Ellison, G.T.H. 2017. Robust causal inference using directed acyclic graphs: the R package ‘dagitty’. International Journal of Epidemiology. 45(6), p.dyw341. Thatcher, T.L., Lai, A.C.K., Moreno-Jackson, R., Sextro, R.G. and Nazaroff, W.W. 2002. Effects of room furnishings and air speed on particle deposition rates indoors. Atmospheric Environment. 36(11), pp.1811–1819. Tran, D.T., Alleman, L.Y., Coddeville, P. and Galloo, J.C. 2017. Indoor particle dynamics in schools: Determination of air exchange rate, size-resolved particle deposition rate and penetration factor in real-life conditions. Indoor and Built Environment. 26(10), pp.1335–1350. Van-Kleef, E., Robotham, Julie V, et al., 2013. Modelling the transmission of healthcare associated infections: a systematic review. BMC Infectious Diseases. 13(1), p.294. Vatter, P., Hoenes, K. and Hessling, M. 2021. Photoinactivation of the Coronavirus Surrogate phi6 by Visible Light. Photochemistry and Photobiology. 97(1), pp.122–125. Verani, M., Bigazzi, R. and Carducci, A. 2014. American Journal of Infection Control Viral contamination of aerosol and surfaces through toilet use in health care and other settings. American Journal of Infection Control. 42(7), pp.758–762. Viechtbauer, W. 2010. Conducting meta-analyses in R with the metafor. Journal of Statistical Software. 36(3), pp.1–48. Viechtbauer, W. and Cheung, M.W.-L. 2010. Outlier and influence diagnostics for meta-analysis. Research Synthesis Methods. 1(2), pp.112–125. Viegas, C., Ramos, C., Almeida, M., Sabino, R., Veríssimo, C. and Rosado, L. 2011. Air fungal contamination in ten hospitals’ food units from Lisbon. WIT Transactions on Ecology and the Environment. 152, pp.127–132. Vouriot, C.V.M., Burridge, H.C., Noakes, C.J. and Linden, P.F. 2021. Seasonal variation in airborne infection risk in schools due to changes in ventilation inferred from monitored carbon dioxide. Indoor Air. 31(4), pp.1154–1163. Wade, T., Heneghan, C., Roberts, N., Curtis, D., Williams, V. and Onakpoya, I. 2021. Healthcare-associated infections and the prescribing of antibiotics in hospitalized patients of the Caribbean Community (CARICOM) States: a mixed-methods systematic review. Journal of Hospital Infection. 110, pp.122–132. White, L.F., Dancer, S.J., Robertson, C. and McDonald, J. 2008. Are hygiene standards useful in assessing infection risk? American Journal of Infection Control. 36(5), pp.381–384. WHO 2016. Quantitative Microbial Risk Assessment: Application for Water Safety Management. WHO Press., p.187. Whyte, W. and Eaton, T. 2016. Deposition velocities of airborne microbecarrying particles. European Journal of Parenteral and Pharmaceutical Sciences. 21(2), pp.45–49. Whyte, W., Hodgson, R. and Tinkler, J. 1982. The importance of airborne bacterial contamination of wounds. Journal of Hospital Infection. 3(2), pp.123–135. Wilson, A.M., King, M.-F., López-García, M., Clifton, I.J., Proctor, J., Reynolds, K.A. and Noakes, C.J. 2021. Effects of patient room layout on viral accruement on healthcare professionals’ hands. Indoor Air. 31(5), pp.1657–1672. Wirmann, L., Ross, B., Reimann, O., Steinmann, J. and Rath, P.M. 2018. Airborne Aspergillus fumigatus spore concentration during demolition of a building on a hospital site, and patient risk determination for invasive aspergillosis including azole resistance. Journal of Hospital Infection. 100(3), pp.e91–e97. Wong, V., Staniforth, K. and Boswell, T.C. 2011. Environmental contamination and airborne microbial counts: A role for hydroxyl radical disinfection units? Journal of Hospital Infection. 78(3), pp.194–199. Xie, G., Roiko, A., Stratton, H., Lemckert, C., Dunn, P.K. and Mengersen, K. 2017. Guidelines for use of the approximate beta-Poisson dose–response model. Risk Analysis. 37(7), pp.1388–1402. Xie, X., Li, Y., Chwang, A.T.Y., Ho, P.L. and Seto, W.H. 2007. How far droplets can move in indoor environments - revisiting the Wells evaporation-falling curve. Indoor Air. 17(3), pp.211–225. Yang, C.T., Liao, C.J., Liu, J.C., Den, W., Chou, Y.C. and Tsai, J.J. 2014. Construction and application of an intelligent air quality monitoring system for healthcare environment. Journal of Medical Systems. 38(2), p.15. Ziaee, A., Zia, M. and Goli, M. 2018. Identification of saprophytic and allergenic fungi in indoor and outdoor environments. Environmental Monitoring and Assessment. 190(10), pp.1–11. Zorman, T. and Jeršek, B. 2008. Assessment of bioaerosol concentrations in different indoor environments. Indoor and Built Environment. 17(2), pp.155–163. Zoz, F., Iaconelli, C., Lang, E., Iddir, H., Guyot, S., Grandvalet, C., Gervais, P. and Beney, L. 2016. Control of Relative Air Humidity as a Potential Means to Improve Hygiene on Surfaces: A Preliminary Approach with Listeria monocytogenes A. Almeida, ed. PLOS ONE. 11(2), p.e0148418."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.858650"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["1955605"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/30957/1/Hiwar_Waseem_Civil%20Engineering_PhD_2022.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hospital acquired infections (HAIs) incur mortalities and high costs for treatment including the ongoing outbreak of the COVID-19 pandemic as a result of contaminated air and surfaces. Understanding the relationship between microorganisms in the air and on surfaces and assessing how hospital environment factors affect this relationship is essential to mitigate the infection risk. A systematic review and meta-analysis showed that there were positive correlations between the airborne bacteria measured as aerobic colony count (ACC) and indoor air quality (IAQ) parameters in the hospital. Also, previous mathematical approaches to correlating air and surface microorganisms were identified and evaluated against published data. Environmental sampling was carried out to explore the transient relationships between air and surface bioburden in a hospital. The average concentration of ACC in air was 196±103 cfu.m-3, while our multi-regression model recommended a maximum of 118 cfu.m-3. High touch surfaces in 1-bed, 4-bed, and 10-bed rooms, found 100%, 84%, and 73% surface deposition samples within an accepted level of concentration (<2.5 cfu.cm-2). The loss rate due to deposition onto surfaces (λ_d) was 7.2±2.88h-1 for ACC and 4.32±2.88h-1 for Staphylococcus spp. The effect of ventilation and spatial location on (λ_d) was investigated by developing and validating a novel Automated Multiplate Passive Air Sampling (AMPAS) device. Increasing the ventilation rate from 3 to 6 ACH results in a reduction of Staphylococcus aureus load in air and on surfaces by 45%±10% and 44%±32%, respectively and λ_d was 1.38±0.48h-1 in the chamber. The relationship between microorganisms in the air and on surfaces is a significant parameter in an infection risk model. It can be represented by λ_d, however this is complex to determine in a dynamic environment. The findings support the importance of controlling the ventilation and the environmental parameters to mitigate both air and surface infection risks in the hospital environment."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Factors that affect the relationship between microorganisms in the air and on surfaces in hospital environments"]}]}],"canonical_facts":{"dc:contributor.advisor":["Noakes, Catherine","Fletcher, Louise"],"dc:contributor.sponsor":["EPSRC"],"dc:creator":["Hiwar, Waseem Faeq Mohammed"],"dc:date":["2021-11"],"dc:date.issued":["2021-11"],"dc:description.abstract":["Hospital acquired infections (HAIs) incur mortalities and high costs for treatment including the ongoing outbreak of the COVID-19 pandemic as a result of contaminated air and surfaces. Understanding the relationship between microorganisms in the air and on surfaces and assessing how hospital environment factors affect this relationship is essential to mitigate the infection risk. A systematic review and meta-analysis showed that there were positive correlations between the airborne bacteria measured as aerobic colony count (ACC) and indoor air quality (IAQ) parameters in the hospital. Also, previous mathematical approaches to correlating air and surface microorganisms were identified and evaluated against published data. Environmental sampling was carried out to explore the transient relationships between air and surface bioburden in a hospital. The average concentration of ACC in air was 196±103 cfu.m-3, while our multi-regression model recommended a maximum of 118 cfu.m-3. High touch surfaces in 1-bed, 4-bed, and 10-bed rooms, found 100%, 84%, and 73% surface deposition samples within an accepted level of concentration (<2.5 cfu.cm-2). The loss rate due to deposition onto surfaces (λ_d) was 7.2±2.88h-1 for ACC and 4.32±2.88h-1 for Staphylococcus spp. The effect of ventilation and spatial location on (λ_d) was investigated by developing and validating a novel Automated Multiplate Passive Air Sampling (AMPAS) device. Increasing the ventilation rate from 3 to 6 ACH results in a reduction of Staphylococcus aureus load in air and on surfaces by 45%±10% and 44%±32%, respectively and λ_d was 1.38±0.48h-1 in the chamber. The relationship between microorganisms in the air and on surfaces is a significant parameter in an infection risk model. It can be represented by λ_d, however this is complex to determine in a dynamic environment. The findings support the importance of controlling the ventilation and the environmental parameters to mitigate both air and surface infection risks in the hospital environment."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.858650"],"dc:identifier.grantnumber":["1955605"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/30957/1/Hiwar_Waseem_Civil%20Engineering_PhD_2022.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Civil Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/30957/"],"dc:relation.references":["Adams, C.E. and Dancer, S.J. 2020. Dynamic transmission of Staphylococcus aureus in the intensive care unit. International Journal of Environmental Research and Public Health. 17(6), p.2109. Al-Shahwani, M.F. 2005. Bacterial distribution analysis of the atmosphere of two hospitals in lbb, Yemen. Eastern Mediterranean Health Journal. 11(5–6), pp.1115–1119. Alberti, C., Bouakline, A., Ribaud, P., Lacroix, C., Rousselot, P., Leblanc, T. and Derouin, F. 2001. Relationship between environmental fungal contamination and the incidence of invasive aspergillosis in haematology patients. Journal of Hospital Infection. 48(3), pp.198–206. AMS 2021. Winter viruses and COVID-19 could push NHS to breaking point, warns new report | The Academy of Medical Sciences. The academy of medical sciences. Andersen, B.M., Rasch, M., Kvist, J., Tollefsen, T., Lukkassen, R., Sandvik, L. and Welo, A. 2009. Floor cleaning: effect on bacteria and organic materials in hospital rooms. Journal of Hospital Infection. 71(1), pp.57–65. Ao, J., Hao, Z., Zhu, H., Wen, L. and Yang, R. 2014. Environmental Investigations and Molecular Typing of Aspergillus in a Chinese Hospital. Mycopathologia. 177, pp.51–57. Arcy, N.D., Cloutman-green, E., Klein, N. and Spratt, D.A. 2014. American Journal of Infection Control Environmental viral contamination in a pediatric hospital outpatient waiting area : Implications for infection control. American Journal of Infection Control. 42(8), pp.856–860. Arnow, P.M., Sadigh, M., Costas, C., Weil, D. and Chudy, R. 1991. Endemic and epidemic aspergillosis associated with in-hospital replication of Aspergillus organisms. Journal of Infectious Diseases. 164(5), pp.998–1002. Asadi, S., Wexler, A.S., Cappa, C.D., Barreda, S., Bouvier, N.M. and Ristenpart, W.D. 2019. Aerosol emission and superemission during human speech increase with voice loudness. Nature/cientific Reports. Atkinson, J., Chartier, Y., Pessoa-Silva, C.L., Jensen, P., Li, Y. and Seto, W.-H. 2009. Basic concept of ventilation flow rate. Augustowska, M. and Dutkiewicz, J. 2006. Variability of airborne microflora in a hospital ward within a period of one year. Annals of Agricultural and Environmental Medicine. 13(1), pp.99–106. Azimi, F., Naddafi, K., Nabizadeh, R., Hassanvand, M.S., Alimohammadi, M., Afhami, S. and Musavi, S.N. 2013. Fungal air quality in hospital rooms: A case study in Tehran, Iran. Journal of Environmental Health Science and Engineering. 11(1), pp.2–5. Barbolla, R.E., Centrón, D., Maimone, S., Rospide, F., Salgueira, C., Altclas, J. and Catalano, M. 2008. Molecular epidemiology of Acinetobacter baumannii spread in an adult intensive care unit under an endemic setting. American Journal of Infection Control. 36(6), pp.444–452. Barbut, F., Yezli, S., Mimoun, M., Pham, J., Chaouat, M. and Otter, J.A. 2013. Reducing the spread of Acinetobacter baumannii and methicillin-resistant Staphylococcus aureus on a burns unit through the intervention of an infection control bundle. Burns. 39(3), pp.395–403. Barnes, R.A. and Rogers, T.R. 1989. Control of an outbreak of nosocomial aspergillosis by laminar air-flow isolation. Journal of Hospital Infection. 14(2), pp.89–94. Bartlett, M.S., Vermund, S.H., Jacobs, R., Durant, P.J., Shaw, M.M., Smith, J.W., Tang, X., Lu, J.J., Li, B., Jin, S. and Lee, C.H. 1997. Detection of Pneumocystis carinii DNA in air samples: Likely environmental risk to susceptible persons. Journal of Clinical Microbiology. 35(10), pp.2511–2513. Beato Arribas, B., McDonagh, A., Noakes, C. and Sleigh, P. 2015. Assessing the near patient infection risk in isolation rooms. Healthy Buildings-Conference proceedings. Beggs, C.B., Noakes, C.J., Sleigh, P.A., Fletcher, L.A. and Kerr, K.G. 2006. Methodology for determining the susceptibility of airborne microorganisms to irradiation by an upper-room UVGI system. Journal of Aerosol Science. 37(7), pp.885–902. Best, E.L., Fawley, W.N., Parnell, P. and Wilcox, M.H. 2010. The Potential for Airborne Dispersal of Clostridium difficile from Symptomatic Patients. Clinical Infectious Diseases. 50(11), pp.1450–1457. Best, E.L.L., Sandoe, J.A.T. and Wilcox, M.H.H. 2012. Potential for aerosolization of Clostridium difficile after flushing toilets: The role of toilet lids in reducing environmental contamination risk. Journal of Hospital Infection. 80(1), pp.1–5. Bischoff, W.E., Mcnall, R.J., Blevins, M.W., Turner, J.L., Lopareva, E.N., Rota, P.A. and Stehle, J.R. 2016. Detection of measles virus RNA in air and surface specimens in a hospital setting. Journal of Infectious Diseases. 213(4), pp.600–603. Bodey, G.P. and Johnston, D. 1971. Microbiological evaluation of protected environments during patient occupancy. Applied microbiology. 22(5), pp.828–836. Bogusz, A., Stewart, M., Hunter, J., Yip, B., Reid, D., Robertson, C. and Dancer, S.J. 2013. How quickly do hospital surfaces become contaminated after detergent cleaning? Healthcare Infection. 18(1), pp.3–9. Bonnal, C., Leleu, C., Brugière, O., Chochillon, C., Porcher, R., Boelle, P.-Y., Menotti, J., Houze, S., Lucet, J.-C. and Derouin, F. 2015. Relationship between Fungal Colonisation of the Respiratory Tract in Lung Transplant Recipients and Fungal Contamination of the Hospital Environment. PLoS ONE. (6), pp.1–11. Booth, T.F., Kournikakis, B., Bastien, N., Ho, J., et al. 2005. Detection of Airborne Severe Acute Respiratory Syndrome (SARS) Coronavirus and Environmental Contamination in SARS Outbreak Units. The Journal of Infectious Diseases. 191(9), pp.1472–1477. Božić, J., Ilić, P. and Ilić, S. 2019. Indoor air quality in the hospital: The influence of heating, ventilating and conditioning systems. Brazilian Archives of Biology and Technology. 62. Brun, C.P., Miron, D., Silla, L.M.R. and Pasqualotto, A.C. 2013. Fungal spore concentrations in two haematopoietic stem cell transplantation (HSCT) units containing distinct air control systems. Epidemiology and Infection. 141(4), pp.875–879. Brunetti, L., Santoro, E., Cavallo, P., Boccia, G., Motta, O. and Capunzo, M. 2006. Two-years surveillance of fungal contamination in three hospital departments in Campania Region. Journal of Preventive Medicine and Hygiene. 47(1), pp.22–25. Cantium Scientific Limited 2018. Bioaerosol Sampler Operating Manual MicroBio MB2 Bioaerosol Sampler Operating Manual. April. Carducci, A., Verani, M., Lombardi, R., Casini, B. and Privitera, G. 2011. Environmental survey to assess viral contamination of air and surfaces in hospital settings. Journal of Hospital Infection. 77(3), pp.242–247. Carvalho, K.S., Melo, M.C., Melo, G.B. and Gontijo-Filho, P.P. 2007. Hospital surface contamination in wards occupied by patients infected with MRSA or MSSA in a Brazilian university hospital. Journal of Basic and Applied Pharmaceutical Sciences. 28(2), pp.159–163. Cavallo, M., Andreoni, S., Martinotti, M.G., Rinaldi, M. and Fracchia, L. 2013. Monitoring Environmental Aspergillus spp. Contamination and Meteorological Factors in a Haematological Unit. Mycopathologia. 176(5–6), pp.387–394. Centers for Disease Control and Prevention 2003. Guidelines for Environmental Infection Control in Health-Care Facilities.Recommendations from CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC). american society for healthcare engineering/American hospital association. (2003), pp.1–48. Chakrabarti, A., Nayak, N., Kumar, P.S., Talwar, P., Chari, P.S. and Panigrahi, D. 1992. Surveillance of Nosocomial Fungal Infections in a Burn Care Unit. Infection. 20(3), pp.132–135. Cheng, V.C.C., Chen, J.H.K., Wong, S.C.Y., Leung, S.S.M., So, S.Y.C., Lung, D.C., Lee, W.M., Trendell-Smith, N.J., Chan, W.M., Ng, D., To, L., Lie, A.K.W. and Yuen, K.Y. 2015. Hospital Outbreak of Pulmonary and Cutaneous Zygomycosis due to Contaminated Linen Items from Substandard Laundry. Clinical Infectious Diseases. 62(6), pp.714–721. Chughtai, A.A., Stelzer-Braid, S., Rawlinson, W., Pontivivo, G., Wang, Q., Pan, Y., Zhang, D., Zhang, Y., Li, L. and MacIntyre, C.R. 2019. Contamination by respiratory viruses on outer surface of medical masks used by hospital healthcare workers. BMC Infectious Diseases. 19(1). Computing, I.P. 2020. Lab: Controlling a Stepper Motor With an H-Bridge. Available from: https://itp.nyu.edu/physcomp/labs/motors-and-transistors/lab-controlling-a-stepper-motor-with-an-h-bridge/. Cordeiro, R.A., Brilhante, R.S.N., Pantoja, L.D.M., Moreira Filho, R.E., Vieira, P.R.N., Rocha, M.F.G., Monteiro, A.J. and Sidrim, J.J.C. 2010. Isolation of pathogenic yeasts in the air from hospital environments in the city of Fortaleza, northeast Brazil. Brazilian Journal of Infectious Diseases. 14(1), pp.30–34. Creamer, E., Shore, A.C., Deasy, E.C., Galvin, S., Dolan, A., Walley, N., Mchugh, S., Fitzgerald-hughes, D., Sullivan, D.J., Cunney, R., Coleman, D.C. and Humphreys, H. 2014. Air and surface contamination patterns of meticillin-resistant Staphylococcus aureus on eight acute hospital wards. Journal of Hospital Infection. 86(3), pp.201–208. Crimi, P., Argellati, F., Macrina, G., Tinteri, C., Copello, L., Rebora, D., Romania, L. and Rizzetto, R. 2006. Microbiological surveillance of hospital ventilation systems in departments at high risk of nosocomial infections. Journal of Preventive Medicine and Hygiene. 47(3), pp.105–109. Crimi, P., Valgiusti, M., Macrina, G., Grieco, A., Massone, L., Ciucci, A., Ansaldi, F., Sticchi, L., Sasso, L., Del Buono, S. and Durando, P. 2009. Evaluation of microbial contamination of air in two haematology departments equipped with ventilation systems with different filtration devices. Journal of Preventive Medicine and Hygiene. 50(1), pp.33–36. Cundell, A.M. 2018. Microbial Ecology of the Human Skin. Microbial Ecology. 76(1), pp.113–120. Dancer, S.J. 2014. Controlling hospital-acquired infection: Focus on the role of the environment and new technologies for decontamination. Clinical Microbiology Reviews. 27(4), pp.665–690. Dancer, S.J. 2004. How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals. Journal of Hospital Infection. 56(1), pp.10–15. Dancer, S.J. 2009. The role of environmental cleaning in the control of hospital-acquired infection. Journal of Hospital Infection. 73(4), pp.378–385. Dancer, S.J., White, L. and Robertson, C. 2008. Monitoring environmental cleanliness on two surgical wards. International Journal of Environmental Health Research. 18(5), pp.357–364. Demirel, R., Sen, B., Kadaifciler, D., et al., 2017. Indoor airborne fungal pollution in newborn units in Turkey. Environmental Monitoring and Assessment. 189(7). Department of Health 2007. Heating and ventilation systems Health Technical Memorandum Specialised ventilation for healthcare premises. Department of Health / Estates and Facilities Division 2007. Health Technical Memorandum 03-01: Specialised ventilation for healthcare premises. Part A - Design and installation. Döring, G., Hörz, M., Ortelt, J., Grupp, H. and Wolz, C. 1993. Molecular epidemiology of Pseudomonas aeruginosa in an intensive care unit. Epidemiology & Infection. 110(3), pp.427–436. Dougall, L.R., Booth, M.G., Khoo, E., Hood, H., MacGregor, S.J., Anderson, J.G., Timoshkin, I. V. and Maclean, M. 2019. Continuous monitoring of aerial bioburden within intensive care isolation rooms and identification of high-risk activities. Journal of Hospital Infection. 103(2), pp.185–192. Eadie, E., Fletcher, L., Tidswell, E., Mahoney, P.O., Welch, D., Adamson, C.S., Brenner, D.J. and Noakes, C. 2021. Far-UVC efficiently inactivates an airborne pathogen in a room- sized chamber. Research Square. (preprint), pp.1–13. Ehrlich, R., Miller, S. and Walker, R.L. 1970. Relationship Between Atmospheric Temperature and Survival of Airborne Bacteria. Ensor, E., Humphreys, H., Peckham, D., Webster, C. and Knox, A.J. 1996. Is Burkholderia (Pseudomonas) cepacia disseminated from cystic fibrosis patients during physiotherapy? Journal of Hospital Infection. 32(1), pp.9–15. European Committee 2009. EU Guidelines to Good Manufacturing Practice Medicinal Products for Human and Veterinary Use. Handbook of Pharmaceutical Manufacturing Formulations. 2008 (March 2010), pp.79–92. Faires, M.C., Pearl, D.L., Ciccotelli, W.A., Straus, K., Zinken, G., Berke, O., Reid-Smith, R.J. and Weese, J.S. 2012. A prospective study to examine the epidemiology of methicillin-resistant Staphylococcus aureus and Clostridium difficile contamination in the general environment of three community hospitals in southern Ontario, Canada. BMC Infectious Diseases. 12, pp.1–14. Falvey, D.G. and Streifel, A.J. 2007. Ten-year air sample analysis of Aspergillus prevalence in a university hospital. Journal of Hospital Infection. 67(1), pp.35–41. Farmaki, E., Panagopoulou, P., Filioti, J., Farmaki, E. and Maloukou, A. 2007. Filamentous Fungi in a Tertiary Care Hospital : Environmental Surveillance and Susceptibility to Antifungal Drugs. Infection Control & Hospital Epidemiology. 28(1), pp.60–67. La Fauci, V., Genovese, C., Facciolà, A., Palamara, M.A.R. and Squeri, R. 2017. Five-year microbiological monitoring of wards and operating theatres in southern Italy. Journal of Preventive Medicine and Hygiene. 58(2), pp.166–172. Fawcett, T. 2006. An introduction to ROC analysis. Pattern Recognition Letters. 27(8), pp.861–874. Fekadu, S. and Getachewu, B. 2015. Microbiological Assessment of Indoor Air of Teaching Hospital Wards: A case of Jimma University Specialized Hospital. Ethiopian journal of health sciences. 25(2), pp.117–122. Field, A.P. 2003. The Problems in Using Fixed-Effects Models of Meta-Analysis on Real-World Data. Understanding Statistics. 2(2), pp.105–124. Fifield, L.J., Lomas, K.J., Giridharan, R. and Allinson, D. 2018. Hospital wards and modular construction: Summertime overheating and energy efficiency. Building and Environment. 141, pp.28–44. Friberg, B., Friberg, S. and Burman, L.G. 1999. Correlation between surface and air counts of particles carrying aerobic bacteria in operating rooms with turbulent ventilation: An experimental study. Journal of Hospital Infection. 42(1), pp.61–68. Fuchs, N.A. 1986. Methods for determining aerosol concentration. Aerosol Science and Technology. 5(2), pp.123–143. Gammaitoni, L. and Nucci, M.C. 1997. Using a Mathematical Model to Evaluate the Efficacy of TB Control Measures. Emerging Infectious Diseases. 3(3), pp.335–342. Gaudart, J., Cloutman-green, E., Guillas, S., Arcy, N.D., Hartley, J.C., Gant, V. and Klein, N. 2013. Healthcare Environments and Spatial Variability of Healthcare Associated Infection Risk : Cross-Sectional Surveys. PLoS ONE. 8(9), pp.1–8. Gehanno, J.F., Louvel, A., Nouvellon, M. and Caillard, J. 2009. Aerial dispersal of meticillin-resistant Staphylococcus aureus in hospital rooms by infected or colonised patients. Journal of Hospital Infection. 71(3), pp.256–262. Gheith, S., Ranque, S., Bannour, W., Ben Youssef, Y., Khelif, A., Ben Said, M., Njah, M. and Saghrouni, F. 2015. Hospital environment fungal contamination and aspergillosis risk in acute leukaemia patients in Sousse (Tunisia). mycoses. 58, pp.337–342. Gizaw, Z., Gebrehiwot, M. and Yenew, C. 2016. High bacterial load of indoor air in hospital wards : the case of University of Gondar teaching hospital , Northwest Ethiopia. Multidisciplinary Respiratory Medicine., pp.1–7. Grieble, H.G., Colton, R., Bird, T.J., Toigo, A. and Griffith, L. 1970. Fine-particle humidifiers Source of Pseudomonas aeruginosa infections in a respiratory-Disease Unit. the New England Journal of Medicine. 282(10), pp.531–535. Griffith, C.J., Obee, P., Cooper, R.A., Burton, N.F. and Lewis, M. 2007. The effectiveness of existing and modified cleaning regimens in a Welsh hospital. Journal of Hospital Infection. 66(4), pp.352–359. Grover, W.H., Bryan, A.K., Diez-Silva, M., Suresh, S., Higgins, J.M. and Manalis, S.R. 2011. Measuring single-cell density. Proceedings of the National Academy of Sciences of the United States of America. 108(27), p.10992. Guest, J.F., Keating, T., Gould, D. and Wigglesworth, N. 2020. Modelling the annual NHS costs and outcomes attributable to healthcare-associated infections in England. BMJ Open. 10(1), pp.1–11. Gurgui, M., Sanchez, F., March, F., Lopez-contreras, J., Martino, R. and Cotura, A. 2011. Nosocomial outbreak of Blastoschizomyces capitatus associated with contaminated milk in a haematological unit. Journal of Hospital Infection. 78(4), pp.274–278. Haig, C.W., Mackay, W.G., Walker, J.T. and Williams, C. 2016. Bioaerosol sampling: Sampling mechanisms, bioefficiency and field studies. Journal of Hospital Infection. 93(3), pp.242–255. Hambraeus, A. 1988. Aerobiology in the operating room-a review. Journal of Hospital Infection. 11(SUPPL. A), pp.68–76. Hang, J., Li, Y. and Jin, R. 2014. The influence of human walking on the flow and airborne transmission in a six-bed isolation room: Tracer gas simulation. Building and Environment. 77, pp.119–134. Hardy, K.J., Gossain, S., Henderson, N., Drugan, C., Oppenheim, B.A., Gao, F. and Hawkey, P.M. 2007. Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour. Journal of Hospital Infection. 66(4), pp.360–368. Hathway, E.A. 2011. CFD Modelling of Pathogen Transport due to Human Activity. Hathway, E.A., Noakes, C.J., A., F.L., Sleigh, P.A., Clifton, I., W., E. and M. 2013. The Role of Nursing Activities on the Bioaerosol Production in Hospital Wards. Indoor and Built Environment. 22(2), pp.410–421. Hathway, E.A., Noakes, C.J., Sleigh, P.A. and Fletcher, L.A. 2011. CFD simulation of airborne pathogen transport due to human activities. Building and Environment. 46(12), pp.2500–2511. Hedges, L. V. 1982. Fitting Categorical Models to Effect Sizes from a Series of Experiments. Journal of Educational Statistics. 7(2), pp.119–137. Hiwar, W., King, M.F., Shuweihdi, F., Fletcher, L.A., Dancer, S.J. and Noakes, C.J. 2021. What is the relationship between indoor air quality parameters and airborne microorganisms in hospital environments? A systematic review and meta-analysis. Indoor Air. Hosmer, D. w and Lemeshow, S. 2003. Applied Logistic Regression. John Wiley & Sons. (3nd Edition). Hospenthal, D.R., Kwon-Chung, K.J. and Bennett, J.E. 1998. Concentrations of airborne Aspergillus compared to the incidence of invasive aspergillosis: Lack of correlation. Medical Mycology. 36(3), pp.165–168. Howard-Reed, C., Wallace, L. and Emmerich, S.J. 2003. Deposition rates of fine and course particles in residential buildings. Gaithersburg, MD. Available from: https://nvlpubs.nist.gov/nistpubs/Legacy/IR/nistir7068.pdf. Hsu, Y.C., Kung, P.Y., Wu, T.N. and Shen, Y.H. 2012. Characterization of indoor-air bioaerosols in Southern Taiwan. Aerosol and Air Quality Research. 12(4), pp.651–661. Hsueh, P.R., Huang, H.C., Young, T.G., Su, C.Y., Liu, C.S. and Yen, M.Y. 2014. Bacteria killing nanotechnology Bio-Kil effectively reduces bacterial burden in intensive care units. European Journal of Clinical Microbiology and Infectious Diseases. 33(4), pp.591–597. Huang, H.L., Lee, M.K. and Shih, H.W. 2017. Assessment of indoor Bioaerosols in public spaces by real-time measured airborne particles. Aerosol and Air Quality Research. 17(9), pp.2276–2288. Huang, P.Y., Shi, Z.Y., Chen, C.H., Den, W., Huang, H.M. and Tsai, J.J. 2013. Airborne and surface-bound microbial contamination in two intensive care units of a medical center in central Taiwan. Aerosol and Air Quality Research. 13(3), pp.1060–1069. Humphreys, H., Peckhams, D., Knox, A.J., Ensor, E. and Webster, C. 1996. Is Burkholderia disseminated ( Pseudomonas ) cepacia patients during from cystic fibrosis physiotherapy ? Journal of Hospital Infection. 32, pp.9–15. Hunter, J.E. and Schmidt, F.L. 2000. Fixed Effects vs. Random Effects Meta‐Analysis Models: Implications for Cumulative Research Knowledge. International Journal of Selection and Assessment. 8(4), pp.275–292. Jaffal, A.A., Nsanze, H., Bener, A., Ameen, A.S., Banat, I.M. and Mogheth, A.A. El 1997. HOSPITAL AIRBORNE MICROBIAL POLLUTION IN A DESERT COUNTRY. Environment international. 23(2), pp.167–172. Jomha, M.Y., Yusef, H. and Holail, H. 2014. Journal of Global Antimicrobial Resistance Antimicrobial and biocide resistance of bacteria in a Lebanese tertiary care hospital. Integrative Medicine Research. 2(4), pp.299–305. Khojasteh, V.J., Edwards-jones, V., Childs, C. and Foster, H.A. 2007. Prevalence of toxin producing strains of Staphylococcus aureus in a pediatric burns unit. Burns. 33, pp.334–340. Killingley, B., Greatorex, J., Digard, P.,et al., 2016. The environmental deposition of influenza virus from patients infected with influenza A(H1N1)pdm09: Implications for infection prevention and control. Journal of Infection and Public Health. 9(3), pp.278–288. Kim, K.H., Kabir, E. and Jahan, S.A. 2018. Airborne bioaerosols and their impact on human health. Journal of Environmental Sciences (China). 67, pp.23–35. Kim, S.H., Chang, S.Y., Sung, M., Park, J.H., Kim, H. Bin, Lee, H., Choi, J.P., Choi, W.S. and Min, J.Y. 2016a. Extensive Viable Middle East Respiratory Syndrome (MERS) Coronavirus Contamination in Air and Surrounding Environment in MERS Isolation Wards. Clinical Infectious Diseases. 63(3), pp.363–369. King, M.-F., Noakes, C.J., Sleigh, P.A., Bale, S. and Waters, L. 2016. Relationship between healthcare worker surface contacts, care type and hand hygiene: An observational study in a single-bed hospital ward. Journal of Hospital Infection. 94(1), pp.48–51. King, M.F., Camargo-Valero, M.A., Matamoros-Veloza, A., Sleigh, P.A. and Noakes, C.J. 2017a. An effective surrogate tracer technique for S. aureus bioaerosols in a mechanically ventilated hospital room replica using dilute aqueous lithium chloride. Atmosphere. 8(12), p.238. King, M.F., Noakes, C.J., Sleigh, P.A. and Camargo-Valero, M.A. 2013. Bioaerosol deposition in single and two-bed hospital rooms: A numerical and experimental study. Building and Environment. 59, pp.436–447. Krishna, B.V.S., Asha, B.P. and Chandrasekhar, M.R. 2007. Extended-spectrum β-lactamase producing Klebsiella pneumoniae in neonatal intensive care unit. Indian Journal of Pediatrics. 74(10), pp.627–630. Kronman, M.P., Baden, H.P., Jeffries, H.E., Heath, J., Cohen, G.A. and Zerr, D.M. 2007. An investigation of Aspergillus cardiac surgical site infections in 3 pediatric patients. American Journal of Infection Control. 35(5), pp.332–337. Lai, A.C.K. 2002. Particle deposition indoors: a review. Indoor Air. 12(4), pp.211–214. Lai, A.C.K., Wong, L.T., Mui, K.W., Chan, W.Y. and Yu, H.C. 2012. An experimental study of bioaerosol (1-10 μm) deposition in a ventilated chamber. Building and Environment. 56, pp.118–126. Lee, L.D., Berkheiser, M., Jiang, Y., Hackett, B., Hachem, R.Y., Chemaly, R.F. and Raad, I.I. 2007. Risk of Bioaerosol Contamination With Aspergillus Species Before and After Cleaning in Rooms Filtered With High-Efficiency Particulate Air Filters That House Patients With Hematologic Malignancy. Infection Control & Hospital Epidemiology. 28(09), pp.1066–1070. Lee, L.D., Hachem, R.Y., Ms, M.B., Hackett, B., Jiang, Y. and Raad, I.I. 2012. American Journal of Infection Control Hospital environment and invasive aspergillosis in patients with hematologic malignancy. American Journal of Infection Control. 40(3), pp.247–249. Lewis, S. and Clarke, M. 2001. Forest plots: Trying to see the wood and the trees. British Medical Journal. 322(7300), pp.1479–1480. Liberati, A., Altman, D.G., Tetzlaff, J., Mulrow, C., Gøtzsche, P.C., Ioannidis, J.P.A., Clarke, M., Devereaux, P.J., Kleijnen, J. and Moher, D. 2009. The PRISMA Statement for Reporting Systematic Reviews and Meta-Analyses of Studies That Evaluate Health Care Interventions : Explanation and Elaboration. plosmedicine. 6(7). Licina, D., Bhangar, S., Brooks, B., Baker, R., Firek, B., Tang, X., Morowitz, M.J., Banfield, J.F. and Nazaroff, W.W. 2016. Concentrations and sources of airborne particles in a neonatal intensive care unit. PLoS ONE. 11(5), pp.1–17. Liguori, G., Bagattini, M., Gallè, F., Negrone, M., Di Onofrio, V. and Triassi, M. 2010. Automated cleaning of fan coil units with a natural detergent-disinfectant product. Annals of Clinical Microbiology and Antimicrobials. 9, pp.8–12. Liu, Z., Zhuang, W., Hu, X., Zhao, Z., Rong, R., Ding, W., Li, J. and Li, N. 2020. Effect of equipment layout on bioaerosol temporal-spatial distribution and deposition in one BSL-3 laboratory. Building and Environment. 181(July). Lopez, G.U., Gerba, C.P., Tamimi, A.H., Kitajima, M., Maxwell, S.L. and Rose, J.B. 2013. Transfer efficiency of bacteria and viruses from porous and nonporous fomites to fingers under different relative humidity conditions. Applied and Environmental Microbiology. Loveday, H.P., Wilson, J.A., Pratt, R.J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J. and Wilcox, M. 2014. Epic3: National evidence-based guidelines for preventing healthcare-associated infections in nhs hospitals in england. Journal of Hospital Infection. 86(S1), pp.S1–S70. Marr, L.C., Tang, J.W., Van Mullekom, J. and Lakdawala, S.S. 2019. Mechanistic insights into the effect of humidity on airborne influenza virus survival, transmission and incidence. Journal of the Royal Society Interface. 16(150). Martínez-herrera, E.O., Frías-de-león, M.G., Duarte-escalante, E., Calderón-ezquerro, M.C., Jiménez-martínez, M.C., Acosta-altamirano, G., Rivera-becerril, F., Toriello, C. and Reyes-montes, M.R. 2016. Fungal diversity and Aspergillus in hospital environments. Annals of Agricultural and Environmental Medicine. 23(2), pp.264–269. Martins-diniz, J.N., Aparecida, R., Toscano, E. and José, M. 2005. Monitoring of airborne fungus and yeast species in a hospital unit. Rev Saude Publica. 39(3), pp.1–7. Martins-Diniz, J.N., da Silva, R.A.M., Miranda, E.T. and Mendes-Giannini, M.J.S. 2005. [Monitoring of airborne fungus and yeast species in a hospital unit]. Revista de saude publica. 39(3), pp.398–405. Matoušková, I. and Holy, O. 2014. Monitoring of the Environment at the Transplant Unit — Hemato-Oncology Clinic. International Journal of Environmental Research and Public Health. 11(4), pp.9480–9490. Mcdonagh, A., Noakes, C. and Fletcher, L.A. 2013. Experimentally Evaluating the Effectivness of an Upper- Room UVGI System In: 11 REHVA World Congress, Clima 2013- Energy efficient, smart and healthy buildins, 16-19 June 2013 McEldowney, S. and Fletcher, M. 1988. The effect of temperature and relative humidity on the survival of bacteria attached to dry solid surfaces. Letters in Applied Microbiology. 7(4), pp.83–86. McLarnon, N., Edwards, G., Burrow, J., MacLaren, W., Aidoo, K. and Hepher, M. 2006. The efficiency of an air filtration system in the hospital ward. International Journal of Environmental Health Research. 16(4), pp.313–317. Me´heust, D., Gangneux, J.P. and Le Cann, P. 2013. Comparative evaluation of three impactor samplers for measuring airborne bacteria and fungi concentrations. Journal of Occupational and Environmental Hygiene. 10(8), pp.455–459. Meakin, N.S., Bowman, C., Lewis, M.R. and Dancer, S.J. 2012. Comparison of cleaning efficacy between in-use disinfectant and electrolysed water in an English residential care home. Journal of Hospital Infection. 80(2), pp.122–127. Méheust, D., Le Cann, P. and Gangneux, J.P. 2013a. Rapid quantification of viable fungi in hospital environments: Analysis of air and surface samples using solid-phase cytometry. Journal of Hospital Infection. 83(2), pp.122–126. Méheust, D., Le Cann, P., Reboux, G., Millon, L. and Gangneux, J.P. 2014. Indoor fungal contamination: Health risks and measurement methods in hospitals, homes and workplaces. Critical Reviews in Microbiology. 40(3), pp.248–260. Memon, B., Bhutto, G. and Rizvi, W. 2016. Measurement of air contamination in different wards of public sector hospital , Sukkur. Pakistan Journal of Pharmaceutical Sciences. 29(6), pp.2015–2021. Miller, S.L., Nazaroff, W.W., Jimenez, J.L., Boerstra, A., Buonanno, G., Dancer, S.J., Kurnitski, J., Marr, L.C., Morawska, L. and Noakes, C. 2021. Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event. Indoor Air. 31(2), pp.314–323. Mingotti, N., Wood, R., Noakes, C. and Woods, A.W. 2020. The mixing of airborne contaminants by the repeated passage of people along a corridor. Journal of Fluid Mechanics. 903, p.52. Mirhoseini, S.H., Nikaeen, M., Khanahmad, H. and Hatamzadeh, M. 2015. Monitoring of airborne bacteria and aerosols in different wards of hospitals – Particle counting usefulness in investigation of airborne bacteria. Annals of Agricultural and Environmental Medicine. 22(4), pp.670–673. Moher, D., Liberati, A., Tetzlaff, J., Altman, D.G. and Group, T.P. 2009. Preferred Reporting Items for Systematic Reviews and Meta-Analyses : The PRISMA Statement. plosmedicine. 6(7). Montagna, M.T., De Giglio, O., Cristina, M.L., et al., 2017. Evaluation of Legionella air contamination in healthcare facilities by different sampling methods: An Italian multicenter study. International Journal of Environmental Research and Public Health. 14(7), p.670. Montagna, M.T., de Giglio, O., Napoli, C., Lovero, G., Caggiano, G., Delia, M., Pastore, D., Santoro, N. and Specchia, G. 2012. Invasive fungal infections in patients with hematologic malignancies (Aurora Project): Lights and shadows during 18-months surveillance. International Journal of Molecular Sciences. 13(1), pp.774–787. Moore, G., Ali, S., FitzGerald, G., Muzslay, M., Atkinson, S., Smith, S., Cryer, P., Gush, C. and Wilson, A.P.R. 2010. Ward assessment of SmartIdeas Project: Bringing source isolation to the patient. Journal of Hospital Infection. 76(2), pp.103–107. Moore, J.E., Mcllhatton, B., Buchanan, J., Gilpin, D., Shaw, A., Hall, V., Murphy, P.G. and Elborn, J.S. 2002. Occurrence of Burkholderia cepacia in the hospital environment. Irish Journal of Medical Science. 171(3), pp.131–133. Morawska, L., Tang, J.W., Bahnfleth, W., et al., 2020b. How can airborne transmission of COVID-19 indoors be minimised? Environment International. 142, p.105832. Møretrø, T., Heir, E., Mo, K.R., Habimana, O., Abdelgani, A. and Langsrud, S. 2010. Factors affecting survival of Shigatoxin-producing Escherichia coli on abiotic surfaces. International Journal of Food Microbiology. 138(1–2), pp.71–77. Mousavi, M.S., Hadei, M., Majlesi, M., Hopke, P.K., Yarahmadi, M., Emam, B., Kermani, M. and Shahsavani, A. 2019. Investigating the effect of several factors on concentrations of bioaerosols in a well-ventilated hospital environment. Environmental Monitoring and Assessment 2019 191:7. 191(7), pp.1–11. Munoz-Price, L.S., Fajardo-Aquino, Y., Arheart, K.L., Cleary, T., DePascale, D., Pizano, L., Namias, N., Rivera, J.I., O’Hara, J.A. and Doi, Y. 2013. Aerosolization of Acinetobacter baumannii in a trauma ICU. Critical Care Medicine. 41(8), pp.1915–1918. Muzslay, M., Moore, G., Turton, J.F. and Wilson, A.P. 2013a. Dissemination of antibiotic-resistant enterococci within the ward environment: The role of airborne bacteria and the risk posed by unrecognized carriers. American Journal of Infection Control. 41(1), pp.57–60. Nakagawa, S. and Cuthill, I.C. 2007. Effect size, confidence interval and statistical significance: A practical guide for biologists. Biological Reviews. 82(4), pp.591–605. Nandalal, P. and Somashekar, R.K. 2007. Prevalence of Staphylococcus aureus and Pseudomonas aeruginosa in indoor air flora of a district hospital , Mandya , Karnataka. journal of environmental biology. 28(2), pp.197–200. Napoli, C., Marcotrigiano, V. and Montagna, M.T. 2012. Air sampling procedures to evaluate microbial contamination: A comparison between active and passive methods in operating theatres. BMC Public Health. 12(1), p.1. Nazaroff, W.W. 2016. Indoor bioaerosol dynamics. Indoor Air. 26(1), pp.61–78. NHS 2021. Vaccinations in the UK | Coronavirus in the UK. GOV.UK. [Online]. [Accessed 1 October 2021]. Available from: https://coronavirus.data.gov.uk/details/cases. Niaré-Doumbo, S., Normand, A.C., Diallo, Y.L., Dembelé, A.K., Thera, M.A., Diallo, D., Piarroux, R., Doumbo, O. and Ranque, S. 2014. Preliminary Study of the Fungal Ecology at the Haematology and Medical-Oncology Ward in Bamako, Mali. Mycopathologia. 178(1–2), pp.103–109. Nielsen, P. V. 2009. Control of airborne infectious diseases in ventilated spaces. Journal of the Royal Society Interface. 6(SUPPL. 6). Noakes, C.J. and Andrew Sleigh, P. 2009. Mathematical models for assessing the role of airflow on the risk of airborne infection in hospital wards. Journal of the Royal Society Interface. 6(SUPPL. 6). Nunes, Z.G., Martins, A.S., Altoe, A.L.F., Nishikawa, M.M., Leite, M.O., Aguiar, P.F. and Fracalanzza, S.E.L. 2005. Indoor air microbiological evaluation of offices, hospitals, industries, and shopping centers. Memorias do Instituto Oswaldo Cruz. 100(4), pp.351–357. Omelyansky, V.. 1940. Manual in Microbiology. USSR Academy of Sciences, Moscow, Leningrad. Osman, M.E., Ibrahim, H.Y., Yousef, F.A., Elnasr, A.A., Saeed, Y. and Hameed, A.A. 2018. A study on microbiological contamination on air quality in hospitals in Egypt. Indoor and Built Environment. 27(7), pp.953–968. Panagea, S., Winstanley, C., Walshaw, M.J., Ledson, M.J. and Hart, C.A. 2005. Environmental contamination with an epidemic strain of Pseudomonas aeruginosa in a Liverpool cystic fibrosis centre , and study of its survival on dry surfaces. Journal of Hospital Infection. 59, pp.102–107. Panagopoulou, P., Filioti, J., Petrikkos, G., Giakouppi, P., Anatoliotaki, M., Farmaki, E., Kanta, A., Apostolakou, H., Avlami, A., Samonis, G. and Roilides, E. 2002. Environmental surveillance of filamentous fungi in three tertiary care hospitals in Greece. Journal of Hospital Infection. 52, pp.185–191. Pankhurst, L.J., Taylor, J., Cloutman-Green, E.A., Hartley, J.C. and Lai, K.M. 2011. Can Clean-Room Particle Counters be Used as an Infection Control Tool in Hospital Operating Theatres?: http://dx.doi.org/10.1177/1420326X11409467. 21(3), pp.381–391. Park, D.U., Yeom, J.K., Lee, W.J. and Lee, K.M. 2013. Assessment of the levels of airborne bacteria, gram-negative bacteria, and fungi in hospital lobbies. International Journal of Environmental Research and Public Health. 10(2), pp.541–555. Pasquarella, C., Pitzurra, O. and Savino, A. 2000. The index of microbial air contamination. Journal of Hospital Infection. 46(4), pp.241–256. Perdelli, F., Cristina, M.L., Sartini, M., Spagnolo, A.M., Dallera, M., Ottria, G., Lombardi, R., Grimaldi, M. and Orlando, P. 2006. Fungal Contamination in Hospital Environments. Infection Control & Hospital Epidemiology. 27(1), pp.44–47. Perdelli, F., Dallera, M., Cristina, M.L., Sartini, M., Ottria, G., Spagnolo, A.M. and Orlando, P. 2008. A new microbiological problem in intensive care units: Environmental contamination by MRSA with reduced susceptibility to glycopeptides. International Journal of Hygiene and Environmental Health. 211(1–2), pp.213–218. PHE and LSHTM 2021. The contribution of nosocomial infections to the first wave - 28 January 2021. https://www.gov.uk/government/publications/phe., p.12. Picot-Guéraud, R., Khouri, C., Brenier-Pinchart, M.P., Saviuc, P., Fares, A., Sellon, T., Thiebaut-Bertrand, A. and Mallaret, M.R. 2015. En-suite bathrooms in protected haematology wards: A source of filamentous fungal contamination? Journal of Hospital Infection. 91(3), pp.244–249. Pittet, D., Allegranzi, B., Sax H. and Dharan S. Pessoa-Silva CL. Donaldson L. Boyce JM. WHO Global Patient Safety Challenge, W.A. for P.S. 2006. Evidence-based model for hand transmission during patient care and the role of improved practices.[see comment]. The Lancet Infectious Diseases. 6(10), pp.641–652. Prevention, C. for D.C. and n.d. CDC - Hierarchy of Controls - NIOSH Workplace Safety and Health Topic. [Accessed 29 June 2018]. Available from: https://www.cdc.gov/niosh/topics/hierarchy/default.html. Quinn, J.P., Arnow, P.M., Weil, D. and Rosenbluth, J. 1984. Outbreak of JK Diphtheroid Infections Associated with Environmental Contamination. JOURNAL OF CLINICAL MICROBIOLOGY. 19(5), pp.668–671. Rainer, J., Peintner, U. and Pöder, R. 2001. Biodiversity and concentration of airborne fungi in a hospital environment. Mycopathologia. 149(2), pp.87–97. Rawlinson, S., Ciric, L. and Cloutman-Green, E. 2019. How to carry out microbiological sampling of healthcare environment surfaces? A review of current evidence. Journal of Hospital Infection. 103(4), pp.363–374. Ríos-Yuil, J.M., Arenas, R., Fernández, R., Calderón-Ezquerro, M. and Rodriguez-Badillo, R. 2012. Aeromycological study at the intensive care unit of the ‘Dr. Manuel Gea Gonzalez’ General Hospital. Brazilian Journal of Infectious Diseases. 16(5), pp.432–435. Roberts, K., Smith, C.F., Snelling, A.M., Kerr, K.G., Banfield, K.R., Sleigh, P.A. and Beggs, C.B. 2008. Aerial Dissemination of Clostridium difficile spores. BMC Infectious Diseases. 8(7), pp.1–6. Rodrigues, A.G. and Araujo, R. 2007. Comparison of Andersen and honey jar methods for monitoring hospital wards. Indoor and Built Environment. 16(1), pp.71–76. Rohrer, J.M. 2018. Thinking Clearly About Correlations and Causation: Graphical Causal Models for Observational Data. Advances in Methods and Practices in Psychological Science. 1(1), pp.27–42. Rosenbaum, P.R., Hedges, L. and Olkin, I. 1987. Statistical Methods for Meta-Analysis. Journal of the American Statistical Association. 82(397), p.350. Rostami, N., Alidadi, H., Zarrinfar, H. and Salehi, P. 2017. Assessment of indoor and outdoor airborne fungi in an Educational, Research and Treatment Center. Italian Journal of Medicine. 11(1), pp.52–56. Rudnick, S.N. and Milton, D.K. 2003. Risk of indoor airborne infection transmission estimated from carbon dioxide concentration. Indoor Air. 13(3), pp.237–245. Saadoun, I., Jaradat, Z.W., Ali, I., Tayyar, A., Nasser, Z. El and Ababneh, Q. 2015. I ndoor and Built Airborne methicillin-resistant Staphylococcus aureus in the indoor environment of King Abdullah University Hospital , Jordan. Indoor and Built Environment. 24(3), pp.315–323. Sabino, R., Ver, C., Parada, H., Viegas, C., Carolino, E., Clemons, K. V and Stevens, D.A. 2014. Molecular screening of 246 Portuguese Aspergillus isolates among different clinical and environmental sources. Medical Mycology. 52, pp.517–527. Saha, R., Agarawal, S. and Khan, A.M. 2017. Air sampling procedures to evaluate microbial contamination: A comparison between active and passive methods at high‑risk areas in a tertiary care hospital of Delhi. journal of patient safety & infection control. 5(1), pp.18–23. Sajjadi, S.A., Shakeri, H., Haghighi, M.H.M. and Mohammadzade, A. 2016. Microbial indoor air quality of public places in a semi-dry city in Iran. International Journal of Tropical Medicine. 11(4), pp.102–107. Sarfati, J., Traore, F., Camet, J.D., Derouin, F. and Latgej, J.P. 1994. Molecular Epidemiology of Nosocomial Invasive Aspergillosis. JOURNAL OF CLINICAL MICROBIOLOGY. 32(3), pp.684–690. Schmidt, E.A., Coleman, D.L. and Mallison, G.F. 1984. Improved system for floor cleaning in health care facilities. Applied and Environmental Microbiology. 47(5), pp.942–946. Setlhare, G., Malebo, N., Shale, K. and Lues, R. 2014. Identification of airborne microbiota in selected areas in a health-care setting in South Africa. BMC Microbiology. 14(1). Sexton, T., Clarke, P., O’Neill, E., Dillane, T. and Humphreys, H. 2006. Environmental reservoirs of methicillin-resistant Staphylococcus aureus in isolation rooms: Correlation with patient isolates and implications for hospital hygiene. Journal of Hospital Infection. 62(2), pp.187–194. Sheerin, M.P., Granzow, F.E., Anderson, D.J., Burley, B.J., Dombrowski, J.M., English, T.R., Erickson, D.S., Fauber, J.P., Flannery, J.J., Friedman, S.D., Hauck, D.J., Heinlein, R.N., Hosking, N., Johnson, A.L., Keen, M.R., Koenigshofer, D., Langowski, P.H., Locke, M.D., Mages, S.J., Mason, D.M., Mead, K.R., Moeller, R.D., Monroe, K.A., Ninomura, P.T., Olmsted, R.N., Stewart, E., Barnaby, C.S. and Humble, J. 2020. Ventilation of Health Care Facilities. ANSI/ASHRAE/ASHE Addendum p to ANSI/ASHRAE/ASHE Standard 170-2017. 8400. Shimono, N., Hayashi, J. and Matsumoto, H. 2012. Vigorous cleaning and adequate ventilation are necessary to control an outbreak in a neonatal intensive care unit. Journal of Infection and Chemotherapy. 18(3), pp.303–307. Shimose, L.A., Masuda, E., Sfeir, M., Berbel Caban, A., Bueno, M.X., Depascale, D., Spychala, C.N., Cleary, T., Namias, N., Kett, D.H., Doi, Y. and Munoz-Price, L.S. 2016. Carbapenem-Resistant Acinetobacter baumannii: Concomitant Contamination of Air and Environmental Surfaces. Infection Control and Hospital Epidemiology. 37(7), pp.777–781. Shiomori, T., Miyamoto, H., Makishima, K., Yoshida, M., Fujiyoshi, T., Udaka, T., Inaba, T. and Hiraki, N. 2002. Evaluation of bedmaking-related airborne and surface methicillin-resistant Staphylococcus aureus contamination. Journal of Hospital Infection. 50, pp.30–35. Shrestha, R., Shrestha, J.M. and Gurung, B. 2012. Antibiotic usage and its sensitivity pattern in the NICU. Kathmandu University Medical Journal. 10(38), pp.27–32. Smith, J., Adams, C.E., King, M.F., Noakes, C.J., Robertson, C. and Dancer, S.J. 2018a. Is there an association between airborne and surface microbes in the critical care environment? Journal of Hospital Infection. 100(3), pp.e123–e129. Stone, J.W. and Das, B.C. 1986. Investigation of an outbreak of infection with Acinetobacter calcoaceticus in a special care baby unit. Journal of Hospital Infection. 7(1), pp.42–48. Talon, D., Excoffon, L., Tiv, M., Pinçon, A.L., Gbaguidi-Haoré, H. and Bertrand, X. 2008. Environmental reservoirs of meticillin resistant Staphylococcus aureus in patients’ rooms: Potential impact on care practices. British Journal of Infection Control. 9(5), pp.10–14. Tambekar, D.H., Gulhane, P.B. and Bhokare, D.D. 2007. Studies on environmental monitoring of microbial air flora in the hospitals. Journal of Medical Sciences. 7(1), pp.67–73. Tang, J.W. 2009. The effect of environmental parameters on the survival of airborne infectious agents. Journal of the Royal Society Interface. 6(SUPPL. 6). Tang, J.W., Bahnfleth, W.P., Bluyssen, P.M., Buonanno, G., Jimenez, J.L., Kurnitski, J., Li, Y., Miller, S., Sekhar, C., Morawska, L., Marr, L.C., Melikov, A.K., Nazaroff, W.W., Nielsen, P. V., Tellier, R., Wargocki, P. and Dancer, S.J. 2021. Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Journal of Hospital Infection. 110, pp.89–96. Tang, J.W., Noakes, C.J., Nielsen, P. V., Eames, I., Nicolle, A., Li, Y. and Settles, G.S. 2011. Observing and quantifying airflows in the infection control of aerosol- and airborne-transmitted diseases: An overview of approaches. Journal of Hospital Infection. 77(3), pp.213–222. Tekİn, A., Dal, T., Selçuk, C.T. and Devecİ, Ö. 2013. Orthophenylphenol in healthcare environments : a trial related to a new administration method and a review of the literature *. Turkish Journal of Medical Sciences. 43(June 2011), pp.805–809. Textor, J., van der Zander, B., Gilthorpe, M.S., Liśkiewicz, M. and Ellison, G.T.H. 2017. Robust causal inference using directed acyclic graphs: the R package ‘dagitty’. International Journal of Epidemiology. 45(6), p.dyw341. Thatcher, T.L., Lai, A.C.K., Moreno-Jackson, R., Sextro, R.G. and Nazaroff, W.W. 2002. Effects of room furnishings and air speed on particle deposition rates indoors. Atmospheric Environment. 36(11), pp.1811–1819. Tran, D.T., Alleman, L.Y., Coddeville, P. and Galloo, J.C. 2017. Indoor particle dynamics in schools: Determination of air exchange rate, size-resolved particle deposition rate and penetration factor in real-life conditions. Indoor and Built Environment. 26(10), pp.1335–1350. Van-Kleef, E., Robotham, Julie V, et al., 2013. Modelling the transmission of healthcare associated infections: a systematic review. BMC Infectious Diseases. 13(1), p.294. Vatter, P., Hoenes, K. and Hessling, M. 2021. Photoinactivation of the Coronavirus Surrogate phi6 by Visible Light. Photochemistry and Photobiology. 97(1), pp.122–125. Verani, M., Bigazzi, R. and Carducci, A. 2014. American Journal of Infection Control Viral contamination of aerosol and surfaces through toilet use in health care and other settings. American Journal of Infection Control. 42(7), pp.758–762. Viechtbauer, W. 2010. Conducting meta-analyses in R with the metafor. Journal of Statistical Software. 36(3), pp.1–48. Viechtbauer, W. and Cheung, M.W.-L. 2010. Outlier and influence diagnostics for meta-analysis. Research Synthesis Methods. 1(2), pp.112–125. Viegas, C., Ramos, C., Almeida, M., Sabino, R., Veríssimo, C. and Rosado, L. 2011. Air fungal contamination in ten hospitals’ food units from Lisbon. WIT Transactions on Ecology and the Environment. 152, pp.127–132. Vouriot, C.V.M., Burridge, H.C., Noakes, C.J. and Linden, P.F. 2021. Seasonal variation in airborne infection risk in schools due to changes in ventilation inferred from monitored carbon dioxide. Indoor Air. 31(4), pp.1154–1163. Wade, T., Heneghan, C., Roberts, N., Curtis, D., Williams, V. and Onakpoya, I. 2021. Healthcare-associated infections and the prescribing of antibiotics in hospitalized patients of the Caribbean Community (CARICOM) States: a mixed-methods systematic review. Journal of Hospital Infection. 110, pp.122–132. White, L.F., Dancer, S.J., Robertson, C. and McDonald, J. 2008. Are hygiene standards useful in assessing infection risk? American Journal of Infection Control. 36(5), pp.381–384. WHO 2016. Quantitative Microbial Risk Assessment: Application for Water Safety Management. WHO Press., p.187. Whyte, W. and Eaton, T. 2016. Deposition velocities of airborne microbecarrying particles. European Journal of Parenteral and Pharmaceutical Sciences. 21(2), pp.45–49. Whyte, W., Hodgson, R. and Tinkler, J. 1982. The importance of airborne bacterial contamination of wounds. Journal of Hospital Infection. 3(2), pp.123–135. Wilson, A.M., King, M.-F., López-García, M., Clifton, I.J., Proctor, J., Reynolds, K.A. and Noakes, C.J. 2021. Effects of patient room layout on viral accruement on healthcare professionals’ hands. Indoor Air. 31(5), pp.1657–1672. Wirmann, L., Ross, B., Reimann, O., Steinmann, J. and Rath, P.M. 2018. Airborne Aspergillus fumigatus spore concentration during demolition of a building on a hospital site, and patient risk determination for invasive aspergillosis including azole resistance. Journal of Hospital Infection. 100(3), pp.e91–e97. Wong, V., Staniforth, K. and Boswell, T.C. 2011. Environmental contamination and airborne microbial counts: A role for hydroxyl radical disinfection units? Journal of Hospital Infection. 78(3), pp.194–199. Xie, G., Roiko, A., Stratton, H., Lemckert, C., Dunn, P.K. and Mengersen, K. 2017. Guidelines for use of the approximate beta-Poisson dose–response model. Risk Analysis. 37(7), pp.1388–1402. Xie, X., Li, Y., Chwang, A.T.Y., Ho, P.L. and Seto, W.H. 2007. How far droplets can move in indoor environments - revisiting the Wells evaporation-falling curve. Indoor Air. 17(3), pp.211–225. Yang, C.T., Liao, C.J., Liu, J.C., Den, W., Chou, Y.C. and Tsai, J.J. 2014. Construction and application of an intelligent air quality monitoring system for healthcare environment. Journal of Medical Systems. 38(2), p.15. Ziaee, A., Zia, M. and Goli, M. 2018. Identification of saprophytic and allergenic fungi in indoor and outdoor environments. Environmental Monitoring and Assessment. 190(10), pp.1–11. Zorman, T. and Jeršek, B. 2008. Assessment of bioaerosol concentrations in different indoor environments. Indoor and Built Environment. 17(2), pp.155–163. Zoz, F., Iaconelli, C., Lang, E., Iddir, H., Guyot, S., Grandvalet, C., Gervais, P. and Beney, L. 2016. Control of Relative Air Humidity as a Potential Means to Improve Hygiene on Surfaces: A Preliminary Approach with Listeria monocytogenes A. Almeida, ed. PLOS ONE. 11(2), p.e0148418."],"dcterms:accessrights":["public"],"dc:title":["Factors that affect the relationship between microorganisms in the air and on surfaces in hospital environments"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000337423456"]},"updated_at":"2026-11-18T23:18:31Z"}