{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:31361"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:31361","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Novel Displacement Dependent Viscous Damper for Semiactive Control of the Seismic Response of Multistorey Buildings","abstract":null,"abstract_html":null,"abstract_has_math":false,"creators":["KIRAL, ADNAN"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Petkovski, Mihail","Pope, Simon A.","Hajirasouliha, Iman"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-09","date_published":"2022-09","updated_at":"2026-11-18T23:19:17Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/31361/1/Final%20Version%20of%20PhD_ADNAN%20KIRAL.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A31361","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Petkovski, Mihail","Pope, Simon A.","Hajirasouliha, Iman"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["the Ministry of National Education of Türkiye (Turkey)"]},{"key":"dc:creator","label":"Author","values":["KIRAL, ADNAN"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-09"]},{"key":"dc:date.issued","label":"Date","values":["2022-09"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Automatic Control and Systems Engineering (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/31361/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Aiken ID, Nims DK, Whittaker A.S., Kelly JM (1993) Testing of Passive Energy Dissipation Systems. Earthqauke Spectra 9: Aiken LD, Kelly JM, Pall AS (1988) Seismic Response of A Nine-Story Steel Frame With Friction Damped Cross-Bracing Akcelyan S, Lignos DG, Hikino T, Nakashima M (2016) Evaluation of Simplified and State-of-the-Art Analysis Procedures for Steel Frame Buildings Equipped with Supplemental Damping Devices Based on E-Defense Full-Scale Shake Table Tests. J Struct Eng 142:04016024 Alotta G, Cavaleri L, Paola M Di, Ferrotto MF (2016) Solutions for the Design and Increasing of Efficiency of Viscous Dampers. Open Constr Build Technol J 10:106–121 Attard TL (2007) Controlling All Interstory Displacements in Highly Nonlinear Steel Buildings Using Optimal Viscous Damping. J Struct Eng 133:1331–1340 Bayat M, Abdollahzade GR (2011) Analysis of the steel braced frames equipped with ADAS devices under the far field records Casciati F, Magonette G, Marazzi F (2006) Technology of Semiactive Devices and Applications in Vibration Mitigation Casciati F, Rodellar J, Yildirim U (2012) Active and semi-active control of structures – theory and applications: A review of recent advances. J Intell Mater Syst Struct 23:1181–1195 CEN (2013) Eurocode 8: design of structures for earthquake resistance—part 1: general rules, seismic actions and rules for buildings Chang KC, Lai ML, Soong TT, et al (1993) Seismic Behavior and Design Guidelines for Steel Frame Structures with Added Viscoelastic Dampers. Natl Cent Earthq Eng Res Tech Rep 140 Chase JG, Mulligan KJ, Gue A, et al (2006) Re-shaping hysteretic behaviour using semi-active resettable device dampers. Eng Struct 28:1418–1429 Constantinou BMC, Tsopelas P, Member A, et al (2001) Toggle-Brace-Damper Seismic Energy Dissipation Systems. 105–112 Constantinou MC, Whittaker AS, Kalpakidis Y, et al (2007) Performance of Seismic Isolation Hardware under Service and Seismic Loading CSI (2002) SAP2000 Integrated Solution for Structural Analysis and Design Dan M, Kohiyama M (2013) System identification and control improvement of a semi-active controlled base-isolated building using the records of the 2011 Great East Japan Earthquake. Safety, Reliab Risk Life-Cycle Perform ofStructures Infrastructures Datta TK (2003) A state-of-the-art review on Active Control of Structures. ISET J Earthq Technol 40:1–17 De Domenico D, Ricciardi G, Takewaki I (2019) Design strategies of viscous dampers for seismic protection of building structures: A review. Soil Dyn Earthq Eng 118:144–165 Domenico D, Hajirasouliha I (2021) Multi‑level performance‑based design optimisation of steel frames with nonlinear viscous dampers Enrique Martinez-Rueda J, Elnashai AS (1995) A novel technique for the retrofitting of reinforced concrete structures. Eng Struct 17:359–371 Eurocode8 (2004) Eurocode8 FEMA-356 (2000) American Society of Civil Engineers, Fema 356 Prestandard and Commentary for the Seismic Rehabilitation of Building. Rehabilitation Filiatrault A, Tremblay R, Wanitkorkul A (2001) Performance evaluation of passive damping systems for the seismic retrofit of steel moment-resisting frames subjected to near-fieldground motions. Earthq Spectra Fukuda R, Kurino H (2019) Highly efficient semi‐active oil damper with energy recovery system. Japan Archit Rev 2:238–249 Gavin HP, Aldemir U (2005) Optimal Control of Earthquake Response Using Semiactive Isolation. J Eng Mech . https://doi.org/10.1061/ASCE0733-93992005131:8769 Ghaemmaghami AR, Kwon OS (2018) Nonlinear modeling of MDOF structures equipped with viscoelastic dampers with strain, temperature and frequency-dependent properties. Eng Struct 168:903–914 Gherbi A, Belgasmia M (2018) Use of fluid viscous dampers in structural control: a case study. Int J Forensic Eng 4:119 Gidaris I, Taflanidis AA (2015) Performance assessment and optimization of fluid viscous dampers through life-cycle cost criteria and comparison to alternative design approaches. Bull Earthq Eng 13:1003–1028 Guo P (2012) Damping System Designs using Nonlinear Frequency Analysis Approach Hajirasouliha I, Asadi P, Pilakoutas K (2012) An efficient performance‐based seismic design method for reinforced concrete frames. Earthq Eng Struct Dyn 1–6 Hazaveh NK, Rodgers GW, Chase JG, Pampanin S (2017a) Reshaping structural hysteresis response with semi-active viscous damping. Bull Earthq Eng 15:1789–1806 Hazaveh NK, Rodgers GW, Chase JG, Pampanin S (2017b) Experimental Test and Validation of a Direction- and Displacement-Dependent Viscous Damper. J Eng Mech 143:04017132 Ho C, Zhu Y, Lang ZQ, et al (2018) Nonlinear damping based semi-active building isolation system. J Sound Vib 424:302–317 Hrovat D, Barak P, Rabins M (1983) Semi‐Active versus Passive or Active Tuned Mass Dampers for Structural Control. J Eng Mech 109:691–705 Hwang A (1998) Practical Application Issues for the Structural Engineer Hwang JS, Tseng YS (2005) Design formulations for supplemental viscous dampers to highway bridges. Earthq Eng Struct Dyn 34:1627–1642 Infanti S, Papanikolas P, Benzoni G, Castellano MG (2004) Rion-Antirion Bridge : Design And Full-Scale Testing Jansen LM, Dyke SJ (2000) Semiactive Control Strategies for Mr Dampers: Comparative Study. J Eng Mech 795 Kogut PI, Leugering G (2011) Optimal L1-Control in Coefficients for Dirichlet Elliptic Problems: W-Optimal Solutions. J Optim Theory Appl 150:205–232 Kostic SM, Filippou FC (2012) Section Discretization of Fiber Beam-Column Elements for Cyclic Inelastic Response. J Struct Eng 138:592–601 Kurata N, Kobori T, Takahashi M, et al (1999) Actual Seismic Response Controlled Building with Semi-Active Damper System Kurino H, Tagami J, Shimizu K, Kobori T (2003) Switching Oil Damper with Built-in Controller for Structural Control. https://doi.org/10.1061/ASCE0733-94452003129:7895 Lang ZQ, Guo PF, Takewaki I (2013) Output frequency response function based design of additional nonlinear viscous dampers for vibration control of multi-degree-of-freedom systems. J Sound Vib 332:4461–4481 Lavan O (2015) A methodology for the integrated seismic design of nonlinear buildings with supplemental damping. Struct Control Heal Monit. https://doi.org/10.1002/stc Lavan O, Cimellaro GP, Reinhorn AM (2008) Noniterative Optimization Procedure for Seismic Weakening and Damping of Inelastic Structures. J Struct Eng 134:1638–1648 Lavan O, Dargush GF (2009) Multi-objective evolutionary seismic design with passive energy dissipation systems. J Earthq Eng 13:758–790 Lee CT, Moon BY (2005) Study of the simulation model of a displacement-sensitive shock absorber of a vehicle by considering the fluid force. Proc Inst Mech Eng Part D J Automob Eng 219:965–975 Lee CT, Moon BY (2006) Simulation and experimental validation of vehicle dynamic characteristics for displacement-sensitive shock absorber using fluid-flow modelling. Mech Syst Signal Process 20:373–388 Lin W-H, Chopra AK (2003a) Earthquake response of elastic SDF systems with non-linear fluidviscous dampers. J Eng Mech 129: Lin WH, Chopra AK (2003b) Asymmetric one-storey elastic systems with non-linear viscous and viscoelastic dampers: Earthquake response. Earthq Eng Struct Dyn 32:555–577 Lin Y-Y, Chang K-C, Chen C-Y (2008) Direct displacement-based design for seismic retrofit of existing buildings using nonlinear viscous dampers. Bull Earthq Eng 6:535–552 Lynch JP, Law KH (2002) Decentralized control techniques for large scale civil structural systems Martínez-Rueda JE (2002) On the evolution of energy dissipation devices for seismic design. Earthq Spectra 18:309–346 McKenna FT (1997) object- oriented finite element programin: frameworks for analysis, algorithms and parallel computing McNamara RJ, Huang CD, Wan V (2000) Viscous-damper with motion amplification device for high rise building applications. In: Structures Congress 2000: Advanced Technology in Structural Engineering McNamara RJ, Taylor DP, Duflot P (2005) Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings. 1–8 Miyamoto HK, Singh JP (2002) Performance of structures with passive energy dissipators. Earthq Spectra 18:105–119 Mulligan KJ, Chase JG, Mander JB, et al (2008) Nonlinear models and validation for resetable device design and enhanced force capacity. Struct Control Heal Monit 17:301–316 Nabid N, Hajirasouliha I, Escolano Margarit D, Petkovski M (2020) Optimum energy based seismic design of friction dampers in RC structures. Structures 27:2550–2562 Nie S, Zhuang Y, Wang Y, Guo K (2018) Velocity & displacement-dependent damper: A novel passive shock absorber inspired by the semi-active control. Mech Syst Signal Process 99:730–746 Oliveira F, Botto MA, Morais P, Suleman A (2017) Semi-active structural vibration control of base-isolated buildings using magnetorheological dampers. J Low Freq Noise Vib Act Control 37:565–576 Pall AS, Marsh C (1982) Response of Friction Damped Braced Frames. J Struct Div 108: Parulekar YM, Reddy GR (2009) Passive Response Control Systems for Seismic Response Reduction: A State-Of-The-Art Review. Int J Struct Stab Dyn 9:151–177 Patten WN, Sun J, Li G, et al (1999) Field Test of An Intelligent Stiffener For Bridges At The I-35 Walnut Creek Bridge. Earthq Eng Struct Dyn 28:109–126 Ponzo FC, Di Cesare A, Nigro D, et al (2012) Jet-pacs project: Dynamic experimental tests and numerical results obtained for a steel frame equipped with hysteretic damped chevron braces. J Earthq Eng 16:662–685 Pourzeynali S, Mousanejad T (2010) Optimization of Semi-Active Control of Seismically Excited Buildings Using Genetic Algorithms. Trans A Civ Eng 17: Quintana HC (2013) Semiactive Friction Connections for Seismic Control of Multi-Storey Buildings. (PhD thesis) Rahman TAZ, As’arry A, Jalil NAA (2017) Active Vibration Control of a Flexible Beam Structure Using Chaotic Fractal Search Algorithm. Procedia Eng 170:299–306 Rodgers GW, Mander JB, Chase JG, et al (2007) Re-shaping hysteretic behaviour - Spectral analysis and design equations for semi-active structures. Earthq Eng Struct Dyn 36:77–100 Ruiz-Sandoval M., Morales E (2008) Complete Decentralized Displacement Control Algorithm Soong TT, Constantinou MC (1994) Passive and Active Vibration Control in Civil Engineering Symans MD, Constantinou MC (1995) Development and Experimental Study of Semi-Active Fluid Damping Devices for Seismic Protection of Structures Takewaki I (1997) Optimal Damper Placement for Minimum Transfer. Engineering 26:1113–1124 Taylor Device Inc 2020 (2020) FVD Design Manual, Taylor Inc. Taylor DP, Constantinou MC (1996) Development and testing of an improved fluid damper configuration for structures having high rigidity. Proc 69th Shock Vib Symp Tehranizadeh M (2001) Passive energy dissipation device for typical steel frame building in Iran Tsai KC, Chen HW, Hong CP, Su YF (1993) Design of Steel Triangular Plate Energy Absorbers for Seismic-Resistant Construction. Earthqauke Spectra 9: Tsopelas P, Constantinou MC (1994) NCEER-Taisei Research Program on Sliding Seismic Isolation Systems for Bridges: Experimental and Analytical Study of a System Consisting of Sliding Bearings and Fluid Restoring Force/Damping Devices Vargas R, Bruneau M (2007) Effect of Supplemental Viscous Damping on the Seismic Response of Structural Systems with Metallic Dampers. J Struct Eng. https://doi.org/10.1061/ASCE0733-94452007133:101434 Whittaker AS, Bertero V V., Thompson CL, Alonso LJ (1991) Seismic Testing of Steel Plate Energy Dissipation Devices. Earthqauke Spectra Xie Y, Zhang J, Xi W (2018) Effectiveness evaluation and optimal design of nonlinear viscous dampers for inelastic structures under pulse-type ground motions. Earthq Eng Struct Dyn 47:2802–2820 Xu J, Li J (2016) Stochastic dynamic response and reliability assessment of controlled structures with fractional derivative model of viscoelastic dampers. Mech Syst Signal Process 72–73:865–896 Yoshida O, Dyke SJ (2004) Seismic Control of a Nonlinear Benchmark Building Using Smart Dampers. J Eng Mech. https://doi.org/10.1061/ASCE0733-93992004130:4386 Yun HB, Tasbighoo F, Masri SF, et al (2008) Comparison of modeling approaches for full-scale nonlinear viscous dampers. JVC/Journal Vib Control 14:51–76"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/31361/1/Final%20Version%20of%20PhD_ADNAN%20KIRAL.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Novel Displacement Dependent Viscous Damper for Semiactive Control of the Seismic Response of Multistorey Buildings"]}]}],"canonical_facts":{"dc:contributor.advisor":["Petkovski, Mihail","Pope, Simon A.","Hajirasouliha, Iman"],"dc:contributor.sponsor":["the Ministry of National Education of Türkiye (Turkey)"],"dc:creator":["KIRAL, ADNAN"],"dc:date":["2022-09"],"dc:date.issued":["2022-09"],"dc:format":["text"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/31361/1/Final%20Version%20of%20PhD_ADNAN%20KIRAL.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Automatic Control and Systems Engineering (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/31361/"],"dc:relation.references":["Aiken ID, Nims DK, Whittaker A.S., Kelly JM (1993) Testing of Passive Energy Dissipation Systems. Earthqauke Spectra 9: Aiken LD, Kelly JM, Pall AS (1988) Seismic Response of A Nine-Story Steel Frame With Friction Damped Cross-Bracing Akcelyan S, Lignos DG, Hikino T, Nakashima M (2016) Evaluation of Simplified and State-of-the-Art Analysis Procedures for Steel Frame Buildings Equipped with Supplemental Damping Devices Based on E-Defense Full-Scale Shake Table Tests. J Struct Eng 142:04016024 Alotta G, Cavaleri L, Paola M Di, Ferrotto MF (2016) Solutions for the Design and Increasing of Efficiency of Viscous Dampers. Open Constr Build Technol J 10:106–121 Attard TL (2007) Controlling All Interstory Displacements in Highly Nonlinear Steel Buildings Using Optimal Viscous Damping. J Struct Eng 133:1331–1340 Bayat M, Abdollahzade GR (2011) Analysis of the steel braced frames equipped with ADAS devices under the far field records Casciati F, Magonette G, Marazzi F (2006) Technology of Semiactive Devices and Applications in Vibration Mitigation Casciati F, Rodellar J, Yildirim U (2012) Active and semi-active control of structures – theory and applications: A review of recent advances. J Intell Mater Syst Struct 23:1181–1195 CEN (2013) Eurocode 8: design of structures for earthquake resistance—part 1: general rules, seismic actions and rules for buildings Chang KC, Lai ML, Soong TT, et al (1993) Seismic Behavior and Design Guidelines for Steel Frame Structures with Added Viscoelastic Dampers. Natl Cent Earthq Eng Res Tech Rep 140 Chase JG, Mulligan KJ, Gue A, et al (2006) Re-shaping hysteretic behaviour using semi-active resettable device dampers. Eng Struct 28:1418–1429 Constantinou BMC, Tsopelas P, Member A, et al (2001) Toggle-Brace-Damper Seismic Energy Dissipation Systems. 105–112 Constantinou MC, Whittaker AS, Kalpakidis Y, et al (2007) Performance of Seismic Isolation Hardware under Service and Seismic Loading CSI (2002) SAP2000 Integrated Solution for Structural Analysis and Design Dan M, Kohiyama M (2013) System identification and control improvement of a semi-active controlled base-isolated building using the records of the 2011 Great East Japan Earthquake. Safety, Reliab Risk Life-Cycle Perform ofStructures Infrastructures Datta TK (2003) A state-of-the-art review on Active Control of Structures. ISET J Earthq Technol 40:1–17 De Domenico D, Ricciardi G, Takewaki I (2019) Design strategies of viscous dampers for seismic protection of building structures: A review. Soil Dyn Earthq Eng 118:144–165 Domenico D, Hajirasouliha I (2021) Multi‑level performance‑based design optimisation of steel frames with nonlinear viscous dampers Enrique Martinez-Rueda J, Elnashai AS (1995) A novel technique for the retrofitting of reinforced concrete structures. Eng Struct 17:359–371 Eurocode8 (2004) Eurocode8 FEMA-356 (2000) American Society of Civil Engineers, Fema 356 Prestandard and Commentary for the Seismic Rehabilitation of Building. Rehabilitation Filiatrault A, Tremblay R, Wanitkorkul A (2001) Performance evaluation of passive damping systems for the seismic retrofit of steel moment-resisting frames subjected to near-fieldground motions. Earthq Spectra Fukuda R, Kurino H (2019) Highly efficient semi‐active oil damper with energy recovery system. Japan Archit Rev 2:238–249 Gavin HP, Aldemir U (2005) Optimal Control of Earthquake Response Using Semiactive Isolation. J Eng Mech . https://doi.org/10.1061/ASCE0733-93992005131:8769 Ghaemmaghami AR, Kwon OS (2018) Nonlinear modeling of MDOF structures equipped with viscoelastic dampers with strain, temperature and frequency-dependent properties. Eng Struct 168:903–914 Gherbi A, Belgasmia M (2018) Use of fluid viscous dampers in structural control: a case study. Int J Forensic Eng 4:119 Gidaris I, Taflanidis AA (2015) Performance assessment and optimization of fluid viscous dampers through life-cycle cost criteria and comparison to alternative design approaches. Bull Earthq Eng 13:1003–1028 Guo P (2012) Damping System Designs using Nonlinear Frequency Analysis Approach Hajirasouliha I, Asadi P, Pilakoutas K (2012) An efficient performance‐based seismic design method for reinforced concrete frames. Earthq Eng Struct Dyn 1–6 Hazaveh NK, Rodgers GW, Chase JG, Pampanin S (2017a) Reshaping structural hysteresis response with semi-active viscous damping. Bull Earthq Eng 15:1789–1806 Hazaveh NK, Rodgers GW, Chase JG, Pampanin S (2017b) Experimental Test and Validation of a Direction- and Displacement-Dependent Viscous Damper. J Eng Mech 143:04017132 Ho C, Zhu Y, Lang ZQ, et al (2018) Nonlinear damping based semi-active building isolation system. J Sound Vib 424:302–317 Hrovat D, Barak P, Rabins M (1983) Semi‐Active versus Passive or Active Tuned Mass Dampers for Structural Control. J Eng Mech 109:691–705 Hwang A (1998) Practical Application Issues for the Structural Engineer Hwang JS, Tseng YS (2005) Design formulations for supplemental viscous dampers to highway bridges. Earthq Eng Struct Dyn 34:1627–1642 Infanti S, Papanikolas P, Benzoni G, Castellano MG (2004) Rion-Antirion Bridge : Design And Full-Scale Testing Jansen LM, Dyke SJ (2000) Semiactive Control Strategies for Mr Dampers: Comparative Study. J Eng Mech 795 Kogut PI, Leugering G (2011) Optimal L1-Control in Coefficients for Dirichlet Elliptic Problems: W-Optimal Solutions. J Optim Theory Appl 150:205–232 Kostic SM, Filippou FC (2012) Section Discretization of Fiber Beam-Column Elements for Cyclic Inelastic Response. J Struct Eng 138:592–601 Kurata N, Kobori T, Takahashi M, et al (1999) Actual Seismic Response Controlled Building with Semi-Active Damper System Kurino H, Tagami J, Shimizu K, Kobori T (2003) Switching Oil Damper with Built-in Controller for Structural Control. https://doi.org/10.1061/ASCE0733-94452003129:7895 Lang ZQ, Guo PF, Takewaki I (2013) Output frequency response function based design of additional nonlinear viscous dampers for vibration control of multi-degree-of-freedom systems. J Sound Vib 332:4461–4481 Lavan O (2015) A methodology for the integrated seismic design of nonlinear buildings with supplemental damping. Struct Control Heal Monit. https://doi.org/10.1002/stc Lavan O, Cimellaro GP, Reinhorn AM (2008) Noniterative Optimization Procedure for Seismic Weakening and Damping of Inelastic Structures. J Struct Eng 134:1638–1648 Lavan O, Dargush GF (2009) Multi-objective evolutionary seismic design with passive energy dissipation systems. J Earthq Eng 13:758–790 Lee CT, Moon BY (2005) Study of the simulation model of a displacement-sensitive shock absorber of a vehicle by considering the fluid force. Proc Inst Mech Eng Part D J Automob Eng 219:965–975 Lee CT, Moon BY (2006) Simulation and experimental validation of vehicle dynamic characteristics for displacement-sensitive shock absorber using fluid-flow modelling. Mech Syst Signal Process 20:373–388 Lin W-H, Chopra AK (2003a) Earthquake response of elastic SDF systems with non-linear fluidviscous dampers. J Eng Mech 129: Lin WH, Chopra AK (2003b) Asymmetric one-storey elastic systems with non-linear viscous and viscoelastic dampers: Earthquake response. Earthq Eng Struct Dyn 32:555–577 Lin Y-Y, Chang K-C, Chen C-Y (2008) Direct displacement-based design for seismic retrofit of existing buildings using nonlinear viscous dampers. Bull Earthq Eng 6:535–552 Lynch JP, Law KH (2002) Decentralized control techniques for large scale civil structural systems Martínez-Rueda JE (2002) On the evolution of energy dissipation devices for seismic design. Earthq Spectra 18:309–346 McKenna FT (1997) object- oriented finite element programin: frameworks for analysis, algorithms and parallel computing McNamara RJ, Huang CD, Wan V (2000) Viscous-damper with motion amplification device for high rise building applications. In: Structures Congress 2000: Advanced Technology in Structural Engineering McNamara RJ, Taylor DP, Duflot P (2005) Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings. 1–8 Miyamoto HK, Singh JP (2002) Performance of structures with passive energy dissipators. Earthq Spectra 18:105–119 Mulligan KJ, Chase JG, Mander JB, et al (2008) Nonlinear models and validation for resetable device design and enhanced force capacity. Struct Control Heal Monit 17:301–316 Nabid N, Hajirasouliha I, Escolano Margarit D, Petkovski M (2020) Optimum energy based seismic design of friction dampers in RC structures. Structures 27:2550–2562 Nie S, Zhuang Y, Wang Y, Guo K (2018) Velocity & displacement-dependent damper: A novel passive shock absorber inspired by the semi-active control. Mech Syst Signal Process 99:730–746 Oliveira F, Botto MA, Morais P, Suleman A (2017) Semi-active structural vibration control of base-isolated buildings using magnetorheological dampers. J Low Freq Noise Vib Act Control 37:565–576 Pall AS, Marsh C (1982) Response of Friction Damped Braced Frames. J Struct Div 108: Parulekar YM, Reddy GR (2009) Passive Response Control Systems for Seismic Response Reduction: A State-Of-The-Art Review. Int J Struct Stab Dyn 9:151–177 Patten WN, Sun J, Li G, et al (1999) Field Test of An Intelligent Stiffener For Bridges At The I-35 Walnut Creek Bridge. Earthq Eng Struct Dyn 28:109–126 Ponzo FC, Di Cesare A, Nigro D, et al (2012) Jet-pacs project: Dynamic experimental tests and numerical results obtained for a steel frame equipped with hysteretic damped chevron braces. J Earthq Eng 16:662–685 Pourzeynali S, Mousanejad T (2010) Optimization of Semi-Active Control of Seismically Excited Buildings Using Genetic Algorithms. Trans A Civ Eng 17: Quintana HC (2013) Semiactive Friction Connections for Seismic Control of Multi-Storey Buildings. (PhD thesis) Rahman TAZ, As’arry A, Jalil NAA (2017) Active Vibration Control of a Flexible Beam Structure Using Chaotic Fractal Search Algorithm. Procedia Eng 170:299–306 Rodgers GW, Mander JB, Chase JG, et al (2007) Re-shaping hysteretic behaviour - Spectral analysis and design equations for semi-active structures. Earthq Eng Struct Dyn 36:77–100 Ruiz-Sandoval M., Morales E (2008) Complete Decentralized Displacement Control Algorithm Soong TT, Constantinou MC (1994) Passive and Active Vibration Control in Civil Engineering Symans MD, Constantinou MC (1995) Development and Experimental Study of Semi-Active Fluid Damping Devices for Seismic Protection of Structures Takewaki I (1997) Optimal Damper Placement for Minimum Transfer. Engineering 26:1113–1124 Taylor Device Inc 2020 (2020) FVD Design Manual, Taylor Inc. Taylor DP, Constantinou MC (1996) Development and testing of an improved fluid damper configuration for structures having high rigidity. Proc 69th Shock Vib Symp Tehranizadeh M (2001) Passive energy dissipation device for typical steel frame building in Iran Tsai KC, Chen HW, Hong CP, Su YF (1993) Design of Steel Triangular Plate Energy Absorbers for Seismic-Resistant Construction. Earthqauke Spectra 9: Tsopelas P, Constantinou MC (1994) NCEER-Taisei Research Program on Sliding Seismic Isolation Systems for Bridges: Experimental and Analytical Study of a System Consisting of Sliding Bearings and Fluid Restoring Force/Damping Devices Vargas R, Bruneau M (2007) Effect of Supplemental Viscous Damping on the Seismic Response of Structural Systems with Metallic Dampers. J Struct Eng. https://doi.org/10.1061/ASCE0733-94452007133:101434 Whittaker AS, Bertero V V., Thompson CL, Alonso LJ (1991) Seismic Testing of Steel Plate Energy Dissipation Devices. Earthqauke Spectra Xie Y, Zhang J, Xi W (2018) Effectiveness evaluation and optimal design of nonlinear viscous dampers for inelastic structures under pulse-type ground motions. Earthq Eng Struct Dyn 47:2802–2820 Xu J, Li J (2016) Stochastic dynamic response and reliability assessment of controlled structures with fractional derivative model of viscoelastic dampers. Mech Syst Signal Process 72–73:865–896 Yoshida O, Dyke SJ (2004) Seismic Control of a Nonlinear Benchmark Building Using Smart Dampers. J Eng Mech. https://doi.org/10.1061/ASCE0733-93992004130:4386 Yun HB, Tasbighoo F, Masri SF, et al (2008) Comparison of modeling approaches for full-scale nonlinear viscous dampers. JVC/Journal Vib Control 14:51–76"],"dcterms:accessrights":["public"],"dc:title":["Novel Displacement Dependent Viscous Damper for Semiactive Control of the Seismic Response of Multistorey Buildings"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T23:19:17Z"}