{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:32333"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:32333","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Development and Applications of Near- and Mid-infrared OCT","abstract":"This thesis chronicles the development of a mid-infrared optical coherence tomography (MIROCT) system and various applications of near-infrared (NIR) OCT. With regards to the development of MIR-OCT, the ultimate goal is to build a swept-source system with a commercial external cavity quantum cascade laser, using heterodyne detection to improve the signal-to-noise ratio. We have characterized the sources of noise within the system: quantization noise from the analogue-to-digital convertor, shot noise from the detectors and relative intensity noise (RIN) of the laser. By using pulse-to-pulse normalization with two paired detectors, the RIN measured can be reduced -97dB/Hz to -115dB/Hz. Next, we investigate the feasibility of using polarization-sensitive OCT to quantify the severity of striae distensae. We have shown that the estimated tissue birefringence of striae-affected skin is significantly greater (p<0.001) than visually normal skin. There is also a loose correlation between tissue birefringence and the subjective visual scores. In botany, we have shown that even with a weak acid treatment, it is possible to quantify the effect of acid erosion on teeth. Calculating the slope of the reflectivity profile is a reliable method for quantifying and potentially monitoring the demineralisation of teeth. The results show that the initial reflectivity readings before treatment is an important factor in determining the magnitude of reflectivity changes after treatment. In botany, we aimed to investigate the stability of plant petiole diameter measurements using OCT. We have demonstrated that spectrometer-based OCT can accurately track changes in the diameter of plant petioles, with an accuracy of ~1.0 µm. With regards to biofilm, we aimed to determine whether there is a minimum detectable limit when OCT is used for the quantification of biofilm thickness, and have shown that biofilm as thin as 13.1 µm can be measured.","abstract_html":"This thesis chronicles the development of a mid-infrared optical coherence tomography (MIROCT) system and various applications of near-infrared (NIR) OCT. With regards to the development of MIR-OCT, the ultimate goal is to build a swept-source system with a commercial external cavity quantum cascade laser, using heterodyne detection to improve the signal-to-noise ratio. We have characterized the sources of noise within the system: quantization noise from the analogue-to-digital convertor, shot noise from the detectors and relative intensity noise (RIN) of the laser. By using pulse-to-pulse normalization with two paired detectors, the RIN measured can be reduced -97dB/Hz to -115dB/Hz. Next, we investigate the feasibility of using polarization-sensitive OCT to quantify the severity of striae distensae. We have shown that the estimated tissue birefringence of striae-affected skin is significantly greater (p&lt;0.001) than visually normal skin. There is also a loose correlation between tissue birefringence and the subjective visual scores. In botany, we have shown that even with a weak acid treatment, it is possible to quantify the effect of acid erosion on teeth. Calculating the slope of the reflectivity profile is a reliable method for quantifying and potentially monitoring the demineralisation of teeth. The results show that the initial reflectivity readings before treatment is an important factor in determining the magnitude of reflectivity changes after treatment. In botany, we aimed to investigate the stability of plant petiole diameter measurements using OCT. We have demonstrated that spectrometer-based OCT can accurately track changes in the diameter of plant petioles, with an accuracy of ~1.0 µm. With regards to biofilm, we aimed to determine whether there is a minimum detectable limit when OCT is used for the quantification of biofilm thickness, and have shown that biofilm as thin as 13.1 µm can be measured.","abstract_has_math":false,"creators":["Lin, Wai Ching"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Matcher, Stephen","Groom, Kristian"],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-09","date_published":"2021-09","updated_at":"2026-11-18T23:21:14Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.874985"],"render_values":[{"text":"uk.bl.ethos.874985","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["n/a"],"render_values":[{"text":"n/a","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000212613125"],"render_values":[{"text":"0000-0002-1261-3125","href":"https://orcid.org/0000-0002-1261-3125","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/32333/1/Thesis_WaiChingLin_finalcopy.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A32333","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Matcher, Stephen","Groom, Kristian"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["University of Sheffield"]},{"key":"dc:creator","label":"Author","values":["Lin, Wai Ching"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000212613125"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-09"]},{"key":"dc:date.issued","label":"Date","values":["2021-09"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Electronic and Electrical Engineering (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/32333/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] D. Huang, E. Swanson, C. Lin, J. Schuman, W. Stinson, W. Chang, M. Hee, T. Flotte, K. Gregory, C. Puliafito, and J. Fujimoto, “Optical coherence tomography,” Science 254(5035), 1178–1181 (1991). [2] T. L. Szabo, “Diagnostic Ultrasound Imaging: Inside Out,” 2nd ed. San Diego: Elsevier Science & Technology (2013). [3] B. R. Masters and M. Böhnke, “Three-Dimensional Confocal Microscopy of the Living Human Eye,” Annu. Rev. Biomed. Eng. 4(1), 69–91 (2002). [4] J.A. Izatt and M.A. Choma, “Theory of optical coherence tomography,” in Optical Coherence Tomography, 2nd ed., W. Drexler and J. G. Fujimoto, Eds., Cham: Springer International Publishing, 47-72 (2015). [5] P.H. Tomlins and R.K Wang, “Theory, developments and applications of optical coherence tomography,” J. Appl. Phys. D: Appl. Phys. 38(15), 2519 (2005). [6] E. A. Swanson, D. Huang, C. P. Lin, C. A. Puliafito, M. R. Hee, and J. G. Fujimoto, “High-speed optical coherence domain reflectometry,” Opt. Lett. 17(2), 151 (1992). [7] J. M. Schmitt, A. Knuttel, M. Yadlowsky, and M. A. Eckhaus, “Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering,” Phys. Med. Biol. 39(10), 1705–1720 (1994). [8] B. Bouma, M. E. Brezinski, J. G. Fujimoto, G. J. Tearney, S. A. Boppart, and M. R. Hee, “High-resolution optical coherence tomographic imaging using a mode-locked Ti:Al_2O_3 laser source,” Opt. Lett. 20(13), 1486 (1995). [9] W. Drexler, U. Morgner, F. X. Kärtner, C. Pitris, S. A. Boppart, X. D. Li, E. P. Ippen, and J. G. Fujimoto, “In vivo ultrahigh-resolution optical coherence tomography,” Opt. Lett. 24(17), 1221 (1999). [10] C. Chudoba, J. G. Fujimoto, E. P. Ippen, H.A. Haus, U. Morgner, F. X. Kärtner, V. Scheuer, G. Angelow, and T. Tschudi, “All-solid-state Cr:forsterite laser generating 14-fs pulses at 13 µm,” Opt. Lett. 26(5), 292 (2001). [11] P. Herz, Y. Chen, A. D. Aguirre, J. G. Fujimoto, H. Mashimo, J. M. Schmitt, A. Koski, J. Goodnow, and C. Petersen, “Ultrahigh resolution optical biopsy with endoscopic optical coherence tomography.,” Opt. Express 12(15), 3532–42 (2004). [12] W. Drexler, U. Morgner, R. K. Ghanta, F. X. Kärtner, J. S. Schuman, and J. G. Fujimoto, “Ultrahigh-resolution ophthalmic optical coherence tomography,” Nat. Med. 7(4), 502–506 (2001). [13] A. M. Rollins and J. A. Izatt, “Optimal interferometer designs for optical coherence tomography,” Opt. Lett. 24(21), 1484 (1999). [14] G. L. Abbas, V. W. S. Chan, and T. K. Yee, “Local-oscillator excess-noise suppression for homodyne and heterodyne detection,” Opt. Lett. 8(8), 419 (1983). [15] K. F. Kwong, D. Yankelevich, K. C. Chu, J. P. Heritage, and A. Dienes, “400-Hz mechanical scanning optical delay line,” Opt. Lett. 18(7), 558 (1993). [16] D. C. Edelstein, R. B. Romney, and M. Scheuermann, “Rapid programmable 300 ps optical delay scanner and signal‐averaging system for ultrafast measurements,” Rev. Sci. Instrum. 62(3), 579–583 (1991). [17] J. Szydlo, N. Delachenal, R. Gianotti, R. Wälti, H. Bleuler, and R. . Salathé, “Air-turbine driven optical low-coherence reflectometry at 28.6-kHz scan repetition rate,” Opt. Commun. 154(1–3), 1–4 (1998). [18] Y. S. Jin, S. G. Jeon, G. J. Kim, J. I. Kim, and C. H. Shon, “Rotary Optical Delay Line for Terahertz Pulse Detection,” Conference on Lasers and Electro-Optics - Pacific Rim 2007, 1–2 (2007). [19] A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. El-Zaiat, “Measurement of intraocular distances by backscattering spectral interferometry,” Opt. Commun., 117(1–2), 43–48 (1995). [20] M. Choma, M. Sarunic, C. Yang, and J. Izatt, “Sensitivity advantage of swept source and Fourier domain optical coherence tomography,” Opt. Express 11(18), 2183 (2003). [21] J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, “Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography,” Opt. Lett., 28(21), 2067 (2003). [22] R. Leitgeb, C. Hitzenberger, and A. Fercher, “Performance of fourier domain vs time domain optical coherence tomography,” Opt. Express 11(8), 889 (2003). [23] M. Wojtkowski, R. Leitgeb, A. Kowalczyk, T. Bajraszewski, and A. F. Fercher, “In vivo human retinal imaging by Fourier domain optical coherence tomography,” J. Biomed. Opt. 7(3), 457 (2002). [24] V. J. Srinivasan, M. Wojtkowski, A. J. Witkin, J. S. Duker, T. H. Ko, M. Carvalho, J. S. Schuman, A. Kowalczyk, and J. G. Fujimoto, “High-Definition and 3-dimensional Imaging of Macular Pathologies with High-speed Ultrahigh-Resolution Optical Coherence Tomography,” Ophthalmology 113(11), 2054–2065 (2006). [25] M. Wojtkowski, V. Srinivasan, J. G. Fujimoto, T. Ko, J. S. Schuman, A. Kowalczyk, and J. S. Duker, “Three-dimensional Retinal Imaging with High-Speed Ultrahigh-Resolution Optical Coherence Tomography,” Ophthalmology 112(10), 1734–1746 (2005). [26] B. Potsaid, I. Gorczynska, V. J. Srinivasan, Y. Chen, J. Jiang, A. Cable, and J. G. Fujimoto, “Ultrahigh speed Spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second,” Opt. Express 16(19), 15149 (2008). [27] S. R. Chinn, E. A. Swanson, and J. G. Fujimoto, “Optical coherence tomography using a frequency-tunable optical source,” Opt. Lett. 22(5), 340 (1997). [28] B. Golubovic, B. E. Bouma, G. J. Tearney, and J. G. Fujimoto, “Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser.,” Opt. Lett. 22(22), 1704–1706 (1997). [29] W. Y. Oh, S. H. Yun, G. J. Tearney, and B. E. Bouma, “115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser,” Opt. Lett. 30(23), 3159 (2005). [30] R. Huber, M. Wojtkowski, K. Taira, J. Fujimoto, and K. Hsu, “Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles.,” Opt. Express 13(9), 3513–3528 (2005). [31] R. Huber, M. Wojtkowski, and J. G. Fujimoto, “Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography,” Opt. Express 14(8), 3225 (2006). [32] D. C. Adler, Y. Chen, R. Huber, J. Schmitt, J. Connolly, and J. G. Fujimoto, “Three-dimensional endomicroscopy using optical coherence tomography,” Nat. Photonics 1(12), 709–716 (2007). [33] D. C. Adler, C. Zhou, T.-H. Tsai, J. Schmitt, Q. Huang, H. Mashimo, and J. G. Fujimoto, “Three-dimensional endomicroscopy of the human colon using optical coherence tomography,” Opt. Express 17(2), 784 (2009). [34] R. Gray, and D. Neuhoff, “Quantization,” IEEE transactions on information theory 44(6), 2325-2383 (1998). [35] C. S. Colley, J. C. Hebden, D. T. Delpy, A. D. Cambrey, R. A. Brown, E. A. Zibik, W. H. Ng, L. R. Wilson, and J. W. Cockburn, “Mid-infrared optical coherence tomography,” Rev. Sci. Instrum. 78(12), 123108 (2007). [36] D. T. D. Childs, A. B. Krysa, K. L. Kennedy, D. G. Revin, J. W. Cockburn, R. A. Hogg, and S. J. Matcher, “A Rapid Swept-Source Mid-Infrared Laser,” International Semiconductor Laser Conference 2014, 155–156 (2014). [37] M.J. Weida, D. Arnone, and T. Day, “Tunable QC laser opens up mid-IR sensing applications,” Laser focus world 42(7), S13 (2006). [38] J. Faist, F. Capasso, D.L. Sivco, C. Sirtori, A.L. Hutchinson, and A.Y. Cho, “Quantum cascade laser,” Science 264(5158), 553-556 (1994). [39] A. Wittmann, Y. Bonetti, M. Fischer, J. Faist, S. Blaser, and E. Gini, “Distributed-Feedback Quantum-Cascade Lasers at 9 µm Operating in Continuous Wave Up to 423 K,” IEEE Photon. Technol. Lett., 21(12), 814-816 (2009). [40] G. Luo, C. Peng, H.Q. Le, S.S. Pei, H. Lee, W.Y. Hwang, B. Ishaug, and J. Zheng, “Broadly wavelength-tunable external cavity, mid-infrared quantum cascade lasers,” IEEE J. Quantum Electron., 38(5), 486-494 (2002). [41] A. Hugi, R. Terazzi, Y. Bonetti, A. Wittmann, M. Fischer, M. Beck, J. Faist, and E. Gini, “External cavity quantum cascade laser tunable from 7.6 to 11.4 µm,” Appl. Phys. Lett. 95(6), 061103 (2009). [42] J. Faist, F. Capasso, C. Sirtori, D.L. Sivco, J.N. Baillargeon, A.L. Hutchinson, S.N.G. Chu, and A.Y. Cho, “High power mid‐infrared (λ~ 5 µm) quantum cascade lasers operating above room temperature,” Appl. Phys. Lett. 68(26), 3680-3682 (1996). [43] I. Zorin, R. Su, A. Prylepa, J. Kilgus, M. Brandstetter, and B. Heise, “Mid-infrared Fourier-domain optical coherence tomography with a pyroelectric linear array,” Opt. Express 26(25), 33428-33439 (2018). [44] S. Freer, D. Revin, K. Groom, and S. J. Matcher, “Towards swept-source mid-infrared OCT,” Biophotonics: Photonic Solutions for Better Health Care VI 2018, 70 (2018). [45] C. K. Hitzenberger and M. Pircher, \"MUW Approach of PS OCT,\" Optical Coherence Tomography: Technology and Applications, 1103-1136 (2015). [46] B. Baumann, \"Polarization sensitive optical coherence tomography: a review of technology and applications,\" Appl. Sci. 7(5), 474 (2017). [47] M. Pircher, E. Goetzinger, R. Leitgeb, and C. K. Hitzenberger, \"Three dimensional polarization sensitive OCT of human skin in vivo,\" Opt. Express 12(14), 3236-3244 (2004). [48] B. Fortune, C.F. Burgoyne, G. Cull, J. Reynaud, and L. Wang, “Onset and progression of peripapillary retinal nerve fiber layer (RNFL) retardance changes occur earlier than RNFL thickness changes in experimental glaucoma,” Investig. Ophthalmol. Vis. Sci. 54(8), 5653-5661 (2013). [49] J. F. De Boer, T. E. Milner, M. J. Van Gemert, and J. S. Nelson, \"Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography,\" Opt. Lett. 22(12), 934-936 (1997). [50] C. K. Hitzenberger, E. Götzinger, M. Sticker, M. Pircher, and A. F. Fercher, \"Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography,\" Opt. Express 9(13), 780-790 (2001). [51] J. Zhang, S. Guo, W. Jung, J. S. Nelson, and Z. Chen, \"Determination of birefringence and absolute optic axis orientation using polarization-sensitive optical coherence tomography with PM fibers,\" Opt. Express 11(24) 3262-3270 (2003). [52] S. Makita, M. Yamanari, and Y. Yasuno, \"Generalized Jones matrix optical coherence tomography: performance and local birefringence imaging,\" Opt. Express 18(2), 854-876 (2010). [53] E. Götzinger, M. Pircher, and C. K. Hitzenberger, \"High speed spectral domain polarization sensitive optical coherence tomography of the human retina,\" Opt. Express 13(25), 10217-10229 (2005). [54] M. Yamanari, S. Makita, V. D. Madjarova, T. Yatagai, and Y. Yasuno, \"Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method,\" Opt. Express 14(14), 6502-6515 (2006). [55] R. Su, M. Kirillin, E. W. Chang, E. Sergeeva, S. H. Yun, and L. Mattsson, “Perspectives of mid-infrared optical coherence tomography for inspection and micrometrology of industrial ceramics,” Opt. Express 22(13), 15804 (2014). [56] D. T. D. Childs, R. A. Hogg, D. G. Revin, I. U. Rehman, J. W. Cockburn, and S. J. Matcher, “Sensitivity Advantage of QCL Tunable-Laser Mid-Infrared Spectroscopy Over FTIR Spectroscopy,” Appl. Spectrosc. Rev. 50(10), 822–839 (2015). [57] J. Welzel, E. Lankenau, R. Birngruber, and R. Engelhardt, “Optical coherence tomography of the human skin,” J. Am. Acad. Dermatol. 37(6), 958-963 (1997). [58] J.M. Olmedo, K.E. Warschaw, J.M. Schmitt, and D.L. Swanson, “Optical coherence tomography for the characterization of basal cell carcinoma in vivo: a pilot study,” J. Am. Acad. Dermatol. 55(3), 408-412 (2006). [59] M.A. Boone, S. Norrenberg, G.B. Jemec, and V. Del Marmol, “Imaging actinic keratosis by high‐definition optical coherence tomography. Histomorphologic correlation: a pilot study,” Exp. Dermatol. 22(2), 93-97 (2013). [60] T. Gambichler, P. Regeniter, F.G. Bechara, A. Orlikov, R. Vasa, G. Moussa, M. Stücker, P. Altmeyer, and K. Hoffmann, “Characterization of benign and malignant melanocytic skin lesions using optical coherence tomography in vivo,” J. Am. Acad. Dermatol. 57(4), 629-637 (2007). [61] H. Morsy, S. Kamp, L. Thrane, N. Behrendt, B. Saunder, H. Zayan, E. Abd Elmagid, and G.B. Jemec, “Optical coherence tomography imaging of psoriasis vulgaris: correlation with histology and disease severity,” Arch. Dermatol. Res. 302(2), 105-111 (2010). [62] M.J. Cobb, Y. Chen, R.A. Underwood, M.L. Usui, J. Olerud, and X. Li, “Noninvasive assessment of cutaneous wound healing using ultrahigh-resolution optical coherence tomography,” J. Biomed. Opt. 11(6), 064002 (2006). [63] M.R. Avanaki, and A. Hojjatoleslami, “Skin layer detection of optical coherence tomography images,” Optik 124(22), 5665-5668 (2013). [64] J. Weissman, T. Hancewicz, and P. Kaplan, “Optical coherence tomography of skin for measurement of epidermal thickness by shapelet-based image analysis,” Opt. Express 12(23), 5760-5769 (2004). [65] R.A. Byers, R. Maiti, S.G. Danby, E.J. Pang, B. Mitchell, M.J. Carré, R. Lewis, M.J. Cork, and S.J. Matcher, \"Sub-clinical assessment of atopic dermatitis severity using angiographic optical coherence tomography,\" Biomed. Opt. Express 9, 2001-2017 (2018). [66] B.W. Colston, M.J. Everett, L.B. Da Silva, L.L. Otis, P. Stroeve, and H. Nathel, “Imaging of hard- and soft-tissue structure in the oral cavity by optical coherence tomography,” Appl. Opt. 37(16), 3582-3585 (1998). [67] B.W. Colston, U.S. Sathyam, L.B. DaSilva, M.J. Everett, P. Stroeve, and L.L. Otis, “Dental OCT,” Opt. Express 3(6), 230-238 (1998). [68] F.I. Feldchtein, G.V. Gelikonov, V.M. Gelikonov, R.R. Iksanov, R.V. Kuranov, A.M. Se7geev, N.D. Gladkova, M.N. Ourutina, J.A. Warren, and D.H. Reitze, “In vivo OCT imaging of hard and soft tissue of the oral cavity,” Opt. Express 3(6), 239-250 (1998). [69] D. Fried, J. Xie, S. Shafi, J.D. Featherstone, T. Breunig, and C.Q. Le, “Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography,” J. Biomed. Opt. 7(4), 618-627 (2002). [70] A.K. Braz, C.M. Aguiar, and A.S. Gomes, “Evaluation of the integrity of dental sealants by optical coherence tomography,” Dent. Mater. 27(4), e60-e64 (2011). [71] J.H. Baek, J. Na, B.H. Lee, E. Choi, and W.S. Son, “Optical approach to the periodontal ligament under orthodontic tooth movement: a preliminary study with optical coherence tomography,” Am. J. Orthod. Dentofacial Orthop. 135(2), 252-259 (2009). [72] G. Loeb, and J.K. Barton, “Imaging botanical subjects with optical coherence tomography: a feasibility study,” Transactions of the ASAE, 46(6), 1751 (2003). [73] J.C. Clements, A.V. Zvyagin, K.K.M.B.D. Silva, T. Wanner, D.D. Sampson, and W.A. Cowling, “Optical coherence tomography as a novel tool for non‐destructive measurement of the hull thickness of lupin seeds,” Plant Breed. 123(3), 266-270 (2004). [74] N.K. Ravichandran, R.E. Wijesinghe, M.F. Shirazi, K. Park, S.Y. Lee, H.Y. Jung, M. Jeon, and J. Kim, “In vivo monitoring on growth and spread of gray leaf spot disease in capsicum annuum leaf using spectral domain optical coherence tomography,” J. Spectrosc. 2016 (2016). [75] T. Anna, S. Chakraborty, C.Y. Cheng, V. Srivastava, A. Chiou, and W.C. Kuo, “Elucidation of microstructural changes in leaves during senescence using spectral domain optical coherence tomography,” Sci. Rep. 9(1), 1-10 (2019). [76] M. Wagner, and H. Horn, “Optical coherence tomography in biofilm research: a comprehensive review,” Biotechnol. Bioeng. 114(7), 1386-1402 (2017). [77] C. Xi, D.L. Marks, S. Schlachter, W. Luo, and S.A. Boppart, “High-resolution three-dimensional imaging of biofilm development using optical coherence tomography,” J. Biomed. Opt. 11(3), 034001 (2006). [78] S. West, M. Wagner, C. Engelke, and H. Horn, “Optical coherence tomography for the in situ three-dimensional visualization and quantification of feed spacer channel fouling in reverse osmosis membrane modules,” J. Membr. Sci. 498, 345-352 (2016). [79] M. Wagner, D. Taherzadeh, C. Haisch, and H. Horn, “Investigation of the mesoscale structure and volumetric features of biofilms using optical coherence tomography,” Biotechnol. Bioeng. 107(5), 844-853 (2010). [80] R. Murga, P.S. Stewart, and D. Daly, “Quantitative analysis of biofilm thickness variability,” Biotechnol. Bioeng. 45(6), 503-510 (1995). [81] Y. Shen, C. Huang, G.L. Monroy, D. Janjaroen, N. Derlon, J. Lin, R. Espinosa-Marzal, E. Morgenroth, S.A. Boppart, N.J. Ashbolt, and W.T. Liu, “Response of simulated drinking water biofilm mechanical and structural properties to long-term disinfectant exposure,” Environ. Sci. Technol. 50(4), 1779-1787 (2016). [82] F. Blauert, H. Horn, and M. Wagner, “Time‐resolved biofilm deformation measurements using optical coherence tomography,” Biotechnol. Bioeng. 112(9), 1893-1905 (2015). [1] W.C. Lin, D.G. Revin, and S.J. Matcher, \"Methods for reducing relative intensity noise in swept-source mid-infrared OCT,\" Proc. SPIE 11359, 113590P (2020). [2] W.C. Lin, and S.J. Matcher, “Swept-source OCT using pulsed mid-infrared light,” Proc. SPIE 10890, 108902D (2019). [3] D.T. Childs, R.A. Hogg, D.G. Revin, I.U. Rehman, J.W. Cockburn, and S.J. Matcher, “Sensitivity advantage of QCL tunable-laser mid-infrared spectroscopy over FTIR spectroscopy,” Appl. Spectrosc. Rev. 50(10), 822-839 (2015). [4] D.T.D. Childs, R.A. Hogg, D.G. Revin, I.U. Rehman, J.W. Cockburn, and S.J. Matcher, “The mid-infrared swept laser: life beyond OCT?,” Proc. SPIE 9312, 9312-39 (2015). [5] I. Zorin, R. Su, A. Prylepa, J. Kilgus, M. Brandstetter, and B. Heise, “Mid-infrared Fourier-domain optical coherence tomography with a pyroelectric linear array,” Opt. Express 26(25), 33428-33439 (2018). [6] C.S. Colley, J.C. Hebden, D.T. Delpy, A.D. Cambrey, R.A. Brown, E.A. Zibik, W.H. Ng, L.R. Wilson, and J.W. Cockburn, “Mid-infrared optical coherence tomography,” Rev. Sci. Instrum. 78(12), 123108 (2007). [7] N.M. Israelsen, C.R. Petersen, A. Barh, D. Jain, M. Jensen, G. Hannesschläger, P. Tidemand-Lichtenberg, C. Pedersen, A. Podoleanu, and O. Bang, “Real-time high-resolution mid-infrared optical coherence tomography,” Light Sci. Appl. 8(1), 1-13 (2019). [8] S. Freer, D. Revin, K. Groom, and S.J. Matcher, “Towards swept-source mid-infrared OCT,” Biophotonics: Photonic Solutions for Better Health Care VI, 70 (2018). [1] W.C. Lin, R.A. Byers, W. Li, S.G. Danby, M.J. Cork, and S.J. Matcher, “Imaging striae distensae: a comparison between PS-OCT and digital dermoscopy,” Biomed. Opt. Express 12(6), 3296-3311 (2021). [2] S. Ud-Din, D. McGeorge, and A. Bayat, “Topical management of striae distensae (stretch marks): Prevention and therapy of striae rubrae and albae,” J. Eur. Acad. Dermtol. Venereol. 30(2), 211-222 (2016). [3] S. Shuster, “The cause of striae distensae,” Acta Derm. Venereol. Suppl. 59(85), 161 (1979). [4] S. Cho, E. S. Park, D. H. Lee, K. Li, and J. H. Chung, “Clinical features and risk factors for striae distensae in Korean adolescents”, J. Eur. Acad. Dermatol. Venereol. 20(9), 1108-1113 (2006). [5] R. C. T. Cordeiro, K. G. Zecchin, and A. M. de Moraes, “Expression of estrogen, androgen, and glucocorticoid receptors in recent striae distensae,” Int. J. Dermatol. 49(1), 30–32 (2010). [6] K. S. Lee, Y. J. Rho, S. I. Jang, M. H. Suh, and J. Y. Song, “Decreased expression of collagen and fibronectin genes in striae distensae tissue,” Clin. Exp. Dermatol. 19(4), 285–288 (1994). [7] A. Hague, and A. Bayat, “Therapeutic targets in the management of striae distensae: A systematic review,” J. Am. Acad. Dermatol. 77(3), 559-568 (2017). [8] K. Yamaguchi, N. Suganuma, and K. Ohashi, “Quality of life evaluation in Japanese pregnant women with striae gravidarum: a cross-sectional study,” BMC Res. Notes 5(1), 450 (2012). [9] C. Cho, E. Cho, N. Kim, J. Shin, S. Woo, J. Lee, J. Lee, E. Lee, and J. Ha, \"Biophysical properties of striae rubra and striae alba in human skin: Comparison with normal skin,\" Skin Res. Technol. 25(3), 283-288 (2019). [10] O. Rangel, I. Arias, E. García, and S. Lopez-Padilla, “Topical tretinoin 0.1% for pregnancy-related abdominal striae: an open-label, multicenter, prospective study,” Adv. Ther. 18(4), 181-186 (2001). [11] D. Hexsel, M. Soirefmann, M. D. Porto, J. Schilling‐Souza, C. Siega, and T. Dal'Forno, “Superficial dermabrasion versus topical tretinoin on early striae distensae: a randomized, pilot study,” Dermatol. Surg. 40(5), 537-544 (2014). [12] P. Deprez, “Easy Peel for the Treatment of Stretch Marks,” Int. J. Cosmet. Surg. Aesthet. Dermatol. 2(3), 201-204 (2002). [13] S. Bitencourt, A. Lunardelli, R. H. Amaral, H. B. Dias, E. S. Boschi, and J. R. de Oliveira, “Safety and patient subjective efficacy of using galvanopuncture for the treatment of striae distensae,” J. Cosmet Dermatol. 15(4), 393-398 (2016). [14] A. S. Aldahan, V. V. Shah, S. Mlacker, S. Samarkandy, M. Alsaidan, and K Nouri, “Laser and light treatments for striae distensae: a comprehensive review of the literature,” Am. J. Clin. Dermatol. 17(3), 239-256 (2016). [15] M. Bleve, P. Capra, F. Pavanetto, and P. Perugini, “Ultrasound and 3D skin imaging: Methods to evaluate efficacy of striae distensae treatment,” Dermatol. Res. Pract. 2012, (2012). [16] D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, and C. A. Puliafito, “Optical Coherence Tomography,” Sci. New Ser. 254(5035), 1178–1181 (1991). [17] M. C. Pierce, J. Strasswimmer, B. H. Park, B. Cense, and J. F. De Boer, “Advances in Optical Coherence Tomography Imaging for Dermatology,” J. Invest. Dermatol. 123(3), 458-463 (2004). [18] M. R. Hee, E. A. Swanson, J. G. Fujimoto, and D. Huang, “Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging,” J. Opt. Soc. Am. B 9(6), 903-908 (1992). [19] M. J. Everett, K. Schoenenberger, B. W. Colston, and L. B. Da Silva, “Birefringence characterization of biological tissue by use of optical coherence tomography,” Opt. Lett. 23(3), 228-230 (1998). [20] C. Hitzenberger, E. Goetzinger, M. Sticker, M. Pircher, and A. Fercher, “Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography,” Opt. Express 9(13), 780-790 (2001). [21] M. Pircher, C. K. Hitzenberger, and U. Schmidt-Erfurth, “Polarization sensitive optical coherence tomography in the human eye,” Prog. Retin. Eye Res. 30(6), 431–451 (2011). [22] J. Walther, J. Golde, L. Kirsten, F. Tetschke, F. Hempel, T. Rosenauer, C. Hannig, and E. Koch, “In vivo imaging of human oral hard and soft tissues by polarization-sensitive optical coherence tomography,” J. Biomed. Opt. 22(12), 121717 (2017). [23] B. Baumann, “Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications,” Appl. Sci. 7(5), 474 (2017). [24] M. K. Al-Qaisi, and T. Akkin, “Polarization-sensitive optical coherence tomography based on polarization-maintaining fibers and frequency multiplexing,” Opt. Express 16(17), 13032–13041 (2008). [25] Z. Lu, D. Kasaragod, and S. J. Matcher, “Conical scan polarization-sensitive optical coherence tomography,” Biomed. Opt. Express 5(3), 752–762 (2014). [26] R. Byers, and S. Matcher, “Attenuation of stripe artifacts in optical coherence tomography images through wavelet-FFT filtering,” Biomed. Opt. Express 10(8), 4179-4189 (2019). [27] E. Götzinger, M. Pircher, W. Geitzenauer, C. Ahlers, B. Baumann, S. Michels, U. Schmidt-Erfurth, and C. K. Hitzenberger, \"Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography,\" Opt. Express 16(21), 16410-16422 (2008). [28] L. Chin, X. Yang, R. A. McLaughlin, P. B. Noble, and D. D. Sampson, \"En face parametric imaging of tissue birefringence using polarization-sensitive optical coherence tomography,\" J. Biomed. Opt. 18(6), 066005 (2013). [29] P. Zheng, R.M. Lavker, and A.M. Kligman, “Anatomy of striae,” Br. J. Dermatol. 112(2), 185-193 (1985). [30] S. Makita, M. Yamanari, and Y. Yasuno, \"Generalized Jones matrix optical coherence tomography: performance and local birefringence imaging,\" Opt. Express 18, 854-876 (2010). [31] M. E. H. Jaspers, F. Feroldi, M. Vlig, J. F. de Boer, and P. P. M. van Zuijlen, \"In vivo polarization-sensitive optical coherence tomography of human burn scars: birefringence quantification and correspondence with histologically determined collagen density,\" J. Biomed. Opt. 22(12), 121712 (2017). [32] S. G. Adie, T. R. Hillman, and D. D. Sampson, \"Detection of multiple scattering in optical coherence tomography using the spatial distribution of Stokes vectors,\" Opt. Express 15, 18033-18049 (2007). [33] P. Gong, L. Chin, S. Es’haghian, Y. M. Liew, F. M. Wood, D. D. Sampson, and R. A. McLaughlin, \"Imaging of skin birefringence for human scar assessment using polarization-sensitive optical coherence tomography aided by vascular masking,\" J. Biomed. Opt. 19(12), 126014 (2014). [1] E. O’Sullivan and A. Milosevic, “UK National Clinical Guidelines in Paediatric Dentistry: diagnosis, prevention and management of dental erosion,” Int. J. Paediatr. Dent. 18, 29–38 (2008). [2] O. Fejerskov, B. Nyvad, E.A. Kidd, “Dental caries: The disease and its clinical management,” Oxford, Blackwell Munksgaard 2, 20-48 (2008). [3] A. C. Sosa, J. M. Solis, N. Cruz-Fierro, S. López, and S. Nakagoshi, “Dental Erosion: Causes, diagnostics and treatment.,” J. Oral Res. 3(4), 257–261 (2014). [4] C. H. Wilder-Smith, P. Wilder-Smith, H. Kawakami-Wong, J. Voronets, K. Osann, and A. Lussi, “Quantification of Dental Erosions in Patients With GERD Using Optical Coherence Tomography Before and After Double-Blind, Randomized Treatment With Esomeprazole or Placebo,” Am. J. Gastroenterol. 104(11), 2788–2795 (2009). [5] K. H. Chan, A. C. Chan, C. L. Darling, and D. Fried, “Methods for monitoring erosion using optical coherence tomography,” Lasers in Dentistry XIX, International Society for Optics and Photonics 8566, 856606 (2013). [6] K. H. Chan, H. Tom, and D. Fried, “Monitoring the inhibition of erosion by a CO laser with OCT,” Lasers in Dentistry XX, International Society for Optics and Photonics 8929, 89290F (2014). [7] K. H. Chan, H. Tom, C. L. Darling, and D. Fried, “A method for monitoring enamel erosion using laser irradiated surfaces and optical coherence tomography,” Lasers Surg. Med. 46(9), 672–678 (2014). [8] M. C. D. de Moraes, A. Z. Freitas, and A. C. C. Aranha, “Progression of erosive lesions after Nd:YAG laser and fluoride using optical coherence tomography,” Lasers Med. Sci. 32(1), 1–8 (2017). [9] M. C. Huysmans, A. Young, and C. Ganss, “The role of fluoride in erosion therapy,” Erosive Tooth Wear, Karger Publishers 25, 230-243 (2014). [10] M. A. R. Buzalaf, A. C. Magalhães, and A. Wiegand, “Alternatives to fluoride in the prevention and treatment of dental erosion,” Erosive Tooth Wear, Karger Publishers 25, 244-252 (2014). [11] X. Wang, B. Megert, E. Hellwig, K. W. Neuhaus, and A. Lussi, “Preventing erosion with novel agents,” J. Dent. 39(2), 163–170 (2011). [12] A. Wiegand and T. Attin, “Randomised in situ trial on the effect of milk and CPP-ACP on dental erosion,” J. Dent. 42(9), 1210–1215 (2014). [13] S. Ranjitkar, J. A. Kaidonis, L. C. Richards, and G. C. Townsend, “The effect of CPP–ACP on enamel wear under severe erosive conditions,” Arch. Oral Biol. 54(6), 527–532 (2009). [14] S. Ranjitkar, J. M. Rodriguez, J. A. Kaidonis, L. C. Richards, G. C. Townsend, and D. W. Bartlett, “The effect of casein phosphopeptide–amorphous calcium phosphate on erosive enamel and dentine wear by toothbrush abrasion,” J. Dent. 37(4), 250–254 (2009). [15] A.M.A. Maia, C. Longbottom, A.S.L. Gomes, and J.M. Girkin, “Enamel erosion and prevention efficacy characterized by confocal laser scanning microscope,” Microsc. Res. Tech. 77, 439–45 (2014). [16] R. Kilano, “The effect of Stannous-containing fluoride toothpaste and Tooth Mousse in the prevention of dental erosion: an in-vitro study using Optical Coherence Tomography”, The University of Sheffield, 2018. [17] R. Byers, and S. Matcher, “Attenuation of stripe artifacts in optical coherence tomography images through wavelet-FFT filtering,” Biomed. Opt. Express 10(8), 4179-4189 (2019). [1] S. A. R. Mousavi, A. Chauvin, F. Pascaud, S. Kellenberger, and E. E. Farmer, “Glutamate receptor-like genes mediate leaf-to-leaf wound signalling,” Nature 500(7463), 422–426 (2013). [2] E. E. Farmer, D. Gasperini, and I. F. Acosta, “The squeeze cell hypothesis for the activation of jasmonate synthesis in response to wounding,” New Phytol. 204(2), 282–288 (2014). [3] J. Boadi, \"Clinical applications of ultra-high resolution and phase-sensitive optical coherence tomography,\" University of Sheffield (2016). [4] J. Williams, W. C. Lin, W. Li, S. Wang, S. J. Matcher, and A. A. Chauvet, \"Translating Optical Coherence Tomography Technologies from Clinical Studies to Botany: Real Time Imaging of Long-Distance Signaling in Plants,\" Optical Coherence Tomography, Optical Society of America, OM4E-6 (2020). [1] H.C. Flemming, G. Schaule, T. Griebe, J. Schmitt, and A. Tamachkiarowa, “Biofouling—the Achilles heel of membrane processes,” Desalination, 113(2-3), 215-225 (1997). [2] C. Dreszer, A. D. Wexler, S. Drusová, T. Overdijk, A. Zwijnenburg, H.-C. Flemming, J. C. Kruithof, and J. S. Vrouwenvelder, “In-situ biofilm characterization in membrane systems using Optical Coherence Tomography: Formation, structure, detachment and impact of flux change,” Water Res. 67, 243–254 (2014). [3] S. Chellam, J.G. Jacangelo, T.P. Bonacquisti, and B.A. Schauer, “Effect of pretreatment on surface water nanofiltration,” J. Am. Water Work. Assoc. 89(10), 77-89 (1997). [4] M. Wagner, and H. Horn, “Optical coherence tomography in biofilm research: a comprehensive review,” Biotechnol. Bioeng. 114(7), 1386-1402 (2017). [5] M. Piculell, C. Suarez, C. Li, M. Christensson, F. Persson, M. Wagner, M. Hermansson, K. Jönsson, and T. Welander, “The inhibitory effects of reject water on nitrifying populations grown at different biofilm thickness,” Water Res. 104, 292-302 (2016). [6] M. Wagner, D. Taherzadeh, C. Haisch, and H. Horn, “Investigation of the mesoscale structure and volumetric features of biofilms using optical coherence tomography,” Biotechnol. Bioeng. 107(5), 844-853 (2010). [7] P. Deines, R. Sekar, P.S. Husband, J.B. Boxall, A.M. Osborn, and C.A. Biggs, “A new coupon design for simultaneous analysis of in situ microbial biofilm formation and community structure in drinking water distribution systems,” Appl. Microbiol. Biotechnol. 87(2), 749-756 (2010). [8] K.E. Fish, and J.B. Boxall, “Biofilm microbiome (re)growth dynamics in drinking water distribution systems are impacted by chlorine concentration,” Front. Microbiol. 9, 2519 (2018). [9] F.C. Pick, K.E. Fish, and J.B. Boxall, “Assimilable organic carbon cycling within drinking water distribution systems,” Water Res. 198, 117147 (2021)."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.874985"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["n/a"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/32333/1/Thesis_WaiChingLin_finalcopy.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis chronicles the development of a mid-infrared optical coherence tomography (MIROCT) system and various applications of near-infrared (NIR) OCT. With regards to the development of MIR-OCT, the ultimate goal is to build a swept-source system with a commercial external cavity quantum cascade laser, using heterodyne detection to improve the signal-to-noise ratio. We have characterized the sources of noise within the system: quantization noise from the analogue-to-digital convertor, shot noise from the detectors and relative intensity noise (RIN) of the laser. By using pulse-to-pulse normalization with two paired detectors, the RIN measured can be reduced -97dB/Hz to -115dB/Hz. Next, we investigate the feasibility of using polarization-sensitive OCT to quantify the severity of striae distensae. We have shown that the estimated tissue birefringence of striae-affected skin is significantly greater (p<0.001) than visually normal skin. There is also a loose correlation between tissue birefringence and the subjective visual scores. In botany, we have shown that even with a weak acid treatment, it is possible to quantify the effect of acid erosion on teeth. Calculating the slope of the reflectivity profile is a reliable method for quantifying and potentially monitoring the demineralisation of teeth. The results show that the initial reflectivity readings before treatment is an important factor in determining the magnitude of reflectivity changes after treatment. In botany, we aimed to investigate the stability of plant petiole diameter measurements using OCT. We have demonstrated that spectrometer-based OCT can accurately track changes in the diameter of plant petioles, with an accuracy of ~1.0 µm. With regards to biofilm, we aimed to determine whether there is a minimum detectable limit when OCT is used for the quantification of biofilm thickness, and have shown that biofilm as thin as 13.1 µm can be measured."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development and Applications of Near- and Mid-infrared OCT"]}]}],"canonical_facts":{"dc:contributor.advisor":["Matcher, Stephen","Groom, Kristian"],"dc:contributor.sponsor":["University of Sheffield"],"dc:creator":["Lin, Wai Ching"],"dc:date":["2021-09"],"dc:date.issued":["2021-09"],"dc:description.abstract":["This thesis chronicles the development of a mid-infrared optical coherence tomography (MIROCT) system and various applications of near-infrared (NIR) OCT. With regards to the development of MIR-OCT, the ultimate goal is to build a swept-source system with a commercial external cavity quantum cascade laser, using heterodyne detection to improve the signal-to-noise ratio. We have characterized the sources of noise within the system: quantization noise from the analogue-to-digital convertor, shot noise from the detectors and relative intensity noise (RIN) of the laser. By using pulse-to-pulse normalization with two paired detectors, the RIN measured can be reduced -97dB/Hz to -115dB/Hz. Next, we investigate the feasibility of using polarization-sensitive OCT to quantify the severity of striae distensae. We have shown that the estimated tissue birefringence of striae-affected skin is significantly greater (p<0.001) than visually normal skin. There is also a loose correlation between tissue birefringence and the subjective visual scores. In botany, we have shown that even with a weak acid treatment, it is possible to quantify the effect of acid erosion on teeth. Calculating the slope of the reflectivity profile is a reliable method for quantifying and potentially monitoring the demineralisation of teeth. The results show that the initial reflectivity readings before treatment is an important factor in determining the magnitude of reflectivity changes after treatment. In botany, we aimed to investigate the stability of plant petiole diameter measurements using OCT. We have demonstrated that spectrometer-based OCT can accurately track changes in the diameter of plant petioles, with an accuracy of ~1.0 µm. With regards to biofilm, we aimed to determine whether there is a minimum detectable limit when OCT is used for the quantification of biofilm thickness, and have shown that biofilm as thin as 13.1 µm can be measured."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.874985"],"dc:identifier.grantnumber":["n/a"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/32333/1/Thesis_WaiChingLin_finalcopy.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Electronic and Electrical Engineering (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/32333/"],"dc:relation.references":["[1] D. Huang, E. Swanson, C. Lin, J. Schuman, W. Stinson, W. Chang, M. Hee, T. Flotte, K. Gregory, C. Puliafito, and J. Fujimoto, “Optical coherence tomography,” Science 254(5035), 1178–1181 (1991). [2] T. L. Szabo, “Diagnostic Ultrasound Imaging: Inside Out,” 2nd ed. San Diego: Elsevier Science & Technology (2013). [3] B. R. Masters and M. Böhnke, “Three-Dimensional Confocal Microscopy of the Living Human Eye,” Annu. Rev. Biomed. Eng. 4(1), 69–91 (2002). [4] J.A. Izatt and M.A. Choma, “Theory of optical coherence tomography,” in Optical Coherence Tomography, 2nd ed., W. Drexler and J. G. Fujimoto, Eds., Cham: Springer International Publishing, 47-72 (2015). [5] P.H. Tomlins and R.K Wang, “Theory, developments and applications of optical coherence tomography,” J. Appl. Phys. D: Appl. Phys. 38(15), 2519 (2005). [6] E. A. Swanson, D. Huang, C. P. Lin, C. A. Puliafito, M. R. Hee, and J. G. Fujimoto, “High-speed optical coherence domain reflectometry,” Opt. Lett. 17(2), 151 (1992). [7] J. M. Schmitt, A. Knuttel, M. Yadlowsky, and M. A. Eckhaus, “Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering,” Phys. Med. Biol. 39(10), 1705–1720 (1994). [8] B. Bouma, M. E. Brezinski, J. G. Fujimoto, G. J. Tearney, S. A. Boppart, and M. R. Hee, “High-resolution optical coherence tomographic imaging using a mode-locked Ti:Al_2O_3 laser source,” Opt. Lett. 20(13), 1486 (1995). [9] W. Drexler, U. Morgner, F. X. Kärtner, C. Pitris, S. A. Boppart, X. D. Li, E. P. Ippen, and J. G. Fujimoto, “In vivo ultrahigh-resolution optical coherence tomography,” Opt. Lett. 24(17), 1221 (1999). [10] C. Chudoba, J. G. Fujimoto, E. P. Ippen, H.A. Haus, U. Morgner, F. X. Kärtner, V. Scheuer, G. Angelow, and T. Tschudi, “All-solid-state Cr:forsterite laser generating 14-fs pulses at 13 µm,” Opt. Lett. 26(5), 292 (2001). [11] P. Herz, Y. Chen, A. D. Aguirre, J. G. Fujimoto, H. Mashimo, J. M. Schmitt, A. Koski, J. Goodnow, and C. Petersen, “Ultrahigh resolution optical biopsy with endoscopic optical coherence tomography.,” Opt. Express 12(15), 3532–42 (2004). [12] W. Drexler, U. Morgner, R. K. Ghanta, F. X. Kärtner, J. S. Schuman, and J. G. Fujimoto, “Ultrahigh-resolution ophthalmic optical coherence tomography,” Nat. Med. 7(4), 502–506 (2001). [13] A. M. Rollins and J. A. Izatt, “Optimal interferometer designs for optical coherence tomography,” Opt. Lett. 24(21), 1484 (1999). [14] G. L. Abbas, V. W. S. Chan, and T. K. Yee, “Local-oscillator excess-noise suppression for homodyne and heterodyne detection,” Opt. Lett. 8(8), 419 (1983). [15] K. F. Kwong, D. Yankelevich, K. C. Chu, J. P. Heritage, and A. Dienes, “400-Hz mechanical scanning optical delay line,” Opt. Lett. 18(7), 558 (1993). [16] D. C. Edelstein, R. B. Romney, and M. Scheuermann, “Rapid programmable 300 ps optical delay scanner and signal‐averaging system for ultrafast measurements,” Rev. Sci. Instrum. 62(3), 579–583 (1991). [17] J. Szydlo, N. Delachenal, R. Gianotti, R. Wälti, H. Bleuler, and R. . Salathé, “Air-turbine driven optical low-coherence reflectometry at 28.6-kHz scan repetition rate,” Opt. Commun. 154(1–3), 1–4 (1998). [18] Y. S. Jin, S. G. Jeon, G. J. Kim, J. I. Kim, and C. H. Shon, “Rotary Optical Delay Line for Terahertz Pulse Detection,” Conference on Lasers and Electro-Optics - Pacific Rim 2007, 1–2 (2007). [19] A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. El-Zaiat, “Measurement of intraocular distances by backscattering spectral interferometry,” Opt. Commun., 117(1–2), 43–48 (1995). [20] M. Choma, M. Sarunic, C. Yang, and J. Izatt, “Sensitivity advantage of swept source and Fourier domain optical coherence tomography,” Opt. Express 11(18), 2183 (2003). [21] J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, “Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography,” Opt. Lett., 28(21), 2067 (2003). [22] R. Leitgeb, C. Hitzenberger, and A. Fercher, “Performance of fourier domain vs time domain optical coherence tomography,” Opt. Express 11(8), 889 (2003). [23] M. Wojtkowski, R. Leitgeb, A. Kowalczyk, T. Bajraszewski, and A. F. Fercher, “In vivo human retinal imaging by Fourier domain optical coherence tomography,” J. Biomed. Opt. 7(3), 457 (2002). [24] V. J. Srinivasan, M. Wojtkowski, A. J. Witkin, J. S. Duker, T. H. Ko, M. Carvalho, J. S. Schuman, A. Kowalczyk, and J. G. Fujimoto, “High-Definition and 3-dimensional Imaging of Macular Pathologies with High-speed Ultrahigh-Resolution Optical Coherence Tomography,” Ophthalmology 113(11), 2054–2065 (2006). [25] M. Wojtkowski, V. Srinivasan, J. G. Fujimoto, T. Ko, J. S. Schuman, A. Kowalczyk, and J. S. Duker, “Three-dimensional Retinal Imaging with High-Speed Ultrahigh-Resolution Optical Coherence Tomography,” Ophthalmology 112(10), 1734–1746 (2005). [26] B. Potsaid, I. Gorczynska, V. J. Srinivasan, Y. Chen, J. Jiang, A. Cable, and J. G. Fujimoto, “Ultrahigh speed Spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second,” Opt. Express 16(19), 15149 (2008). [27] S. R. Chinn, E. A. Swanson, and J. G. Fujimoto, “Optical coherence tomography using a frequency-tunable optical source,” Opt. Lett. 22(5), 340 (1997). [28] B. Golubovic, B. E. Bouma, G. J. Tearney, and J. G. Fujimoto, “Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser.,” Opt. Lett. 22(22), 1704–1706 (1997). [29] W. Y. Oh, S. H. Yun, G. J. Tearney, and B. E. Bouma, “115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser,” Opt. Lett. 30(23), 3159 (2005). [30] R. Huber, M. Wojtkowski, K. Taira, J. Fujimoto, and K. Hsu, “Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles.,” Opt. Express 13(9), 3513–3528 (2005). [31] R. Huber, M. Wojtkowski, and J. G. Fujimoto, “Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography,” Opt. Express 14(8), 3225 (2006). [32] D. C. Adler, Y. Chen, R. Huber, J. Schmitt, J. Connolly, and J. G. Fujimoto, “Three-dimensional endomicroscopy using optical coherence tomography,” Nat. Photonics 1(12), 709–716 (2007). [33] D. C. Adler, C. Zhou, T.-H. Tsai, J. Schmitt, Q. Huang, H. Mashimo, and J. G. Fujimoto, “Three-dimensional endomicroscopy of the human colon using optical coherence tomography,” Opt. Express 17(2), 784 (2009). [34] R. Gray, and D. Neuhoff, “Quantization,” IEEE transactions on information theory 44(6), 2325-2383 (1998). [35] C. S. Colley, J. C. Hebden, D. T. Delpy, A. D. Cambrey, R. A. Brown, E. A. Zibik, W. H. Ng, L. R. Wilson, and J. W. Cockburn, “Mid-infrared optical coherence tomography,” Rev. Sci. Instrum. 78(12), 123108 (2007). [36] D. T. D. Childs, A. B. Krysa, K. L. Kennedy, D. G. Revin, J. W. Cockburn, R. A. Hogg, and S. J. Matcher, “A Rapid Swept-Source Mid-Infrared Laser,” International Semiconductor Laser Conference 2014, 155–156 (2014). [37] M.J. Weida, D. Arnone, and T. Day, “Tunable QC laser opens up mid-IR sensing applications,” Laser focus world 42(7), S13 (2006). [38] J. Faist, F. Capasso, D.L. Sivco, C. Sirtori, A.L. Hutchinson, and A.Y. Cho, “Quantum cascade laser,” Science 264(5158), 553-556 (1994). [39] A. Wittmann, Y. Bonetti, M. Fischer, J. Faist, S. Blaser, and E. Gini, “Distributed-Feedback Quantum-Cascade Lasers at 9 µm Operating in Continuous Wave Up to 423 K,” IEEE Photon. Technol. Lett., 21(12), 814-816 (2009). [40] G. Luo, C. Peng, H.Q. Le, S.S. Pei, H. Lee, W.Y. Hwang, B. Ishaug, and J. Zheng, “Broadly wavelength-tunable external cavity, mid-infrared quantum cascade lasers,” IEEE J. Quantum Electron., 38(5), 486-494 (2002). [41] A. Hugi, R. Terazzi, Y. Bonetti, A. Wittmann, M. Fischer, M. Beck, J. Faist, and E. Gini, “External cavity quantum cascade laser tunable from 7.6 to 11.4 µm,” Appl. Phys. Lett. 95(6), 061103 (2009). [42] J. Faist, F. Capasso, C. Sirtori, D.L. Sivco, J.N. Baillargeon, A.L. Hutchinson, S.N.G. Chu, and A.Y. Cho, “High power mid‐infrared (λ~ 5 µm) quantum cascade lasers operating above room temperature,” Appl. Phys. Lett. 68(26), 3680-3682 (1996). [43] I. Zorin, R. Su, A. Prylepa, J. Kilgus, M. Brandstetter, and B. Heise, “Mid-infrared Fourier-domain optical coherence tomography with a pyroelectric linear array,” Opt. Express 26(25), 33428-33439 (2018). [44] S. Freer, D. Revin, K. Groom, and S. J. Matcher, “Towards swept-source mid-infrared OCT,” Biophotonics: Photonic Solutions for Better Health Care VI 2018, 70 (2018). [45] C. K. Hitzenberger and M. Pircher, \"MUW Approach of PS OCT,\" Optical Coherence Tomography: Technology and Applications, 1103-1136 (2015). [46] B. Baumann, \"Polarization sensitive optical coherence tomography: a review of technology and applications,\" Appl. Sci. 7(5), 474 (2017). [47] M. Pircher, E. Goetzinger, R. Leitgeb, and C. K. Hitzenberger, \"Three dimensional polarization sensitive OCT of human skin in vivo,\" Opt. Express 12(14), 3236-3244 (2004). [48] B. Fortune, C.F. Burgoyne, G. Cull, J. Reynaud, and L. Wang, “Onset and progression of peripapillary retinal nerve fiber layer (RNFL) retardance changes occur earlier than RNFL thickness changes in experimental glaucoma,” Investig. Ophthalmol. Vis. Sci. 54(8), 5653-5661 (2013). [49] J. F. De Boer, T. E. Milner, M. J. Van Gemert, and J. S. Nelson, \"Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography,\" Opt. Lett. 22(12), 934-936 (1997). [50] C. K. Hitzenberger, E. Götzinger, M. Sticker, M. Pircher, and A. F. Fercher, \"Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography,\" Opt. Express 9(13), 780-790 (2001). [51] J. Zhang, S. Guo, W. Jung, J. S. Nelson, and Z. Chen, \"Determination of birefringence and absolute optic axis orientation using polarization-sensitive optical coherence tomography with PM fibers,\" Opt. Express 11(24) 3262-3270 (2003). [52] S. Makita, M. Yamanari, and Y. Yasuno, \"Generalized Jones matrix optical coherence tomography: performance and local birefringence imaging,\" Opt. Express 18(2), 854-876 (2010). [53] E. Götzinger, M. Pircher, and C. K. Hitzenberger, \"High speed spectral domain polarization sensitive optical coherence tomography of the human retina,\" Opt. Express 13(25), 10217-10229 (2005). [54] M. Yamanari, S. Makita, V. D. Madjarova, T. Yatagai, and Y. Yasuno, \"Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method,\" Opt. Express 14(14), 6502-6515 (2006). [55] R. Su, M. Kirillin, E. W. Chang, E. Sergeeva, S. H. Yun, and L. Mattsson, “Perspectives of mid-infrared optical coherence tomography for inspection and micrometrology of industrial ceramics,” Opt. Express 22(13), 15804 (2014). [56] D. T. D. Childs, R. A. Hogg, D. G. Revin, I. U. Rehman, J. W. Cockburn, and S. J. Matcher, “Sensitivity Advantage of QCL Tunable-Laser Mid-Infrared Spectroscopy Over FTIR Spectroscopy,” Appl. Spectrosc. Rev. 50(10), 822–839 (2015). [57] J. Welzel, E. Lankenau, R. Birngruber, and R. Engelhardt, “Optical coherence tomography of the human skin,” J. Am. Acad. Dermatol. 37(6), 958-963 (1997). [58] J.M. Olmedo, K.E. Warschaw, J.M. Schmitt, and D.L. Swanson, “Optical coherence tomography for the characterization of basal cell carcinoma in vivo: a pilot study,” J. Am. Acad. Dermatol. 55(3), 408-412 (2006). [59] M.A. Boone, S. Norrenberg, G.B. Jemec, and V. Del Marmol, “Imaging actinic keratosis by high‐definition optical coherence tomography. Histomorphologic correlation: a pilot study,” Exp. Dermatol. 22(2), 93-97 (2013). [60] T. Gambichler, P. Regeniter, F.G. Bechara, A. Orlikov, R. Vasa, G. Moussa, M. Stücker, P. Altmeyer, and K. Hoffmann, “Characterization of benign and malignant melanocytic skin lesions using optical coherence tomography in vivo,” J. Am. Acad. Dermatol. 57(4), 629-637 (2007). [61] H. Morsy, S. Kamp, L. Thrane, N. Behrendt, B. Saunder, H. Zayan, E. Abd Elmagid, and G.B. Jemec, “Optical coherence tomography imaging of psoriasis vulgaris: correlation with histology and disease severity,” Arch. Dermatol. Res. 302(2), 105-111 (2010). [62] M.J. Cobb, Y. Chen, R.A. Underwood, M.L. Usui, J. Olerud, and X. Li, “Noninvasive assessment of cutaneous wound healing using ultrahigh-resolution optical coherence tomography,” J. Biomed. Opt. 11(6), 064002 (2006). [63] M.R. Avanaki, and A. Hojjatoleslami, “Skin layer detection of optical coherence tomography images,” Optik 124(22), 5665-5668 (2013). [64] J. Weissman, T. Hancewicz, and P. Kaplan, “Optical coherence tomography of skin for measurement of epidermal thickness by shapelet-based image analysis,” Opt. Express 12(23), 5760-5769 (2004). [65] R.A. Byers, R. Maiti, S.G. Danby, E.J. Pang, B. Mitchell, M.J. Carré, R. Lewis, M.J. Cork, and S.J. Matcher, \"Sub-clinical assessment of atopic dermatitis severity using angiographic optical coherence tomography,\" Biomed. Opt. Express 9, 2001-2017 (2018). [66] B.W. Colston, M.J. Everett, L.B. Da Silva, L.L. Otis, P. Stroeve, and H. Nathel, “Imaging of hard- and soft-tissue structure in the oral cavity by optical coherence tomography,” Appl. Opt. 37(16), 3582-3585 (1998). [67] B.W. Colston, U.S. Sathyam, L.B. DaSilva, M.J. Everett, P. Stroeve, and L.L. Otis, “Dental OCT,” Opt. Express 3(6), 230-238 (1998). [68] F.I. Feldchtein, G.V. Gelikonov, V.M. Gelikonov, R.R. Iksanov, R.V. Kuranov, A.M. Se7geev, N.D. Gladkova, M.N. Ourutina, J.A. Warren, and D.H. Reitze, “In vivo OCT imaging of hard and soft tissue of the oral cavity,” Opt. Express 3(6), 239-250 (1998). [69] D. Fried, J. Xie, S. Shafi, J.D. Featherstone, T. Breunig, and C.Q. Le, “Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography,” J. Biomed. Opt. 7(4), 618-627 (2002). [70] A.K. Braz, C.M. Aguiar, and A.S. Gomes, “Evaluation of the integrity of dental sealants by optical coherence tomography,” Dent. Mater. 27(4), e60-e64 (2011). [71] J.H. Baek, J. Na, B.H. Lee, E. Choi, and W.S. Son, “Optical approach to the periodontal ligament under orthodontic tooth movement: a preliminary study with optical coherence tomography,” Am. J. Orthod. Dentofacial Orthop. 135(2), 252-259 (2009). [72] G. Loeb, and J.K. Barton, “Imaging botanical subjects with optical coherence tomography: a feasibility study,” Transactions of the ASAE, 46(6), 1751 (2003). [73] J.C. Clements, A.V. Zvyagin, K.K.M.B.D. Silva, T. Wanner, D.D. Sampson, and W.A. Cowling, “Optical coherence tomography as a novel tool for non‐destructive measurement of the hull thickness of lupin seeds,” Plant Breed. 123(3), 266-270 (2004). [74] N.K. Ravichandran, R.E. Wijesinghe, M.F. Shirazi, K. Park, S.Y. Lee, H.Y. Jung, M. Jeon, and J. Kim, “In vivo monitoring on growth and spread of gray leaf spot disease in capsicum annuum leaf using spectral domain optical coherence tomography,” J. Spectrosc. 2016 (2016). [75] T. Anna, S. Chakraborty, C.Y. Cheng, V. Srivastava, A. Chiou, and W.C. Kuo, “Elucidation of microstructural changes in leaves during senescence using spectral domain optical coherence tomography,” Sci. Rep. 9(1), 1-10 (2019). [76] M. Wagner, and H. Horn, “Optical coherence tomography in biofilm research: a comprehensive review,” Biotechnol. Bioeng. 114(7), 1386-1402 (2017). [77] C. Xi, D.L. Marks, S. Schlachter, W. Luo, and S.A. Boppart, “High-resolution three-dimensional imaging of biofilm development using optical coherence tomography,” J. Biomed. Opt. 11(3), 034001 (2006). [78] S. West, M. Wagner, C. Engelke, and H. Horn, “Optical coherence tomography for the in situ three-dimensional visualization and quantification of feed spacer channel fouling in reverse osmosis membrane modules,” J. Membr. Sci. 498, 345-352 (2016). [79] M. Wagner, D. Taherzadeh, C. Haisch, and H. Horn, “Investigation of the mesoscale structure and volumetric features of biofilms using optical coherence tomography,” Biotechnol. Bioeng. 107(5), 844-853 (2010). [80] R. Murga, P.S. Stewart, and D. Daly, “Quantitative analysis of biofilm thickness variability,” Biotechnol. Bioeng. 45(6), 503-510 (1995). [81] Y. Shen, C. Huang, G.L. Monroy, D. Janjaroen, N. Derlon, J. Lin, R. Espinosa-Marzal, E. Morgenroth, S.A. Boppart, N.J. Ashbolt, and W.T. Liu, “Response of simulated drinking water biofilm mechanical and structural properties to long-term disinfectant exposure,” Environ. Sci. Technol. 50(4), 1779-1787 (2016). [82] F. Blauert, H. Horn, and M. Wagner, “Time‐resolved biofilm deformation measurements using optical coherence tomography,” Biotechnol. Bioeng. 112(9), 1893-1905 (2015). [1] W.C. Lin, D.G. Revin, and S.J. Matcher, \"Methods for reducing relative intensity noise in swept-source mid-infrared OCT,\" Proc. SPIE 11359, 113590P (2020). [2] W.C. Lin, and S.J. Matcher, “Swept-source OCT using pulsed mid-infrared light,” Proc. SPIE 10890, 108902D (2019). [3] D.T. Childs, R.A. Hogg, D.G. Revin, I.U. Rehman, J.W. Cockburn, and S.J. Matcher, “Sensitivity advantage of QCL tunable-laser mid-infrared spectroscopy over FTIR spectroscopy,” Appl. Spectrosc. Rev. 50(10), 822-839 (2015). [4] D.T.D. Childs, R.A. Hogg, D.G. Revin, I.U. Rehman, J.W. Cockburn, and S.J. Matcher, “The mid-infrared swept laser: life beyond OCT?,” Proc. SPIE 9312, 9312-39 (2015). [5] I. Zorin, R. Su, A. Prylepa, J. Kilgus, M. Brandstetter, and B. Heise, “Mid-infrared Fourier-domain optical coherence tomography with a pyroelectric linear array,” Opt. Express 26(25), 33428-33439 (2018). [6] C.S. Colley, J.C. Hebden, D.T. Delpy, A.D. Cambrey, R.A. Brown, E.A. Zibik, W.H. Ng, L.R. Wilson, and J.W. Cockburn, “Mid-infrared optical coherence tomography,” Rev. Sci. Instrum. 78(12), 123108 (2007). [7] N.M. Israelsen, C.R. Petersen, A. Barh, D. Jain, M. Jensen, G. Hannesschläger, P. Tidemand-Lichtenberg, C. Pedersen, A. Podoleanu, and O. Bang, “Real-time high-resolution mid-infrared optical coherence tomography,” Light Sci. Appl. 8(1), 1-13 (2019). [8] S. Freer, D. Revin, K. Groom, and S.J. Matcher, “Towards swept-source mid-infrared OCT,” Biophotonics: Photonic Solutions for Better Health Care VI, 70 (2018). [1] W.C. Lin, R.A. Byers, W. Li, S.G. Danby, M.J. Cork, and S.J. Matcher, “Imaging striae distensae: a comparison between PS-OCT and digital dermoscopy,” Biomed. Opt. Express 12(6), 3296-3311 (2021). [2] S. Ud-Din, D. McGeorge, and A. Bayat, “Topical management of striae distensae (stretch marks): Prevention and therapy of striae rubrae and albae,” J. Eur. Acad. Dermtol. Venereol. 30(2), 211-222 (2016). [3] S. Shuster, “The cause of striae distensae,” Acta Derm. Venereol. Suppl. 59(85), 161 (1979). [4] S. Cho, E. S. Park, D. H. Lee, K. Li, and J. H. Chung, “Clinical features and risk factors for striae distensae in Korean adolescents”, J. Eur. Acad. Dermatol. Venereol. 20(9), 1108-1113 (2006). [5] R. C. T. Cordeiro, K. G. Zecchin, and A. M. de Moraes, “Expression of estrogen, androgen, and glucocorticoid receptors in recent striae distensae,” Int. J. Dermatol. 49(1), 30–32 (2010). [6] K. S. Lee, Y. J. Rho, S. I. Jang, M. H. Suh, and J. Y. Song, “Decreased expression of collagen and fibronectin genes in striae distensae tissue,” Clin. Exp. Dermatol. 19(4), 285–288 (1994). [7] A. Hague, and A. Bayat, “Therapeutic targets in the management of striae distensae: A systematic review,” J. Am. Acad. Dermatol. 77(3), 559-568 (2017). [8] K. Yamaguchi, N. Suganuma, and K. Ohashi, “Quality of life evaluation in Japanese pregnant women with striae gravidarum: a cross-sectional study,” BMC Res. Notes 5(1), 450 (2012). [9] C. Cho, E. Cho, N. Kim, J. Shin, S. Woo, J. Lee, J. Lee, E. Lee, and J. Ha, \"Biophysical properties of striae rubra and striae alba in human skin: Comparison with normal skin,\" Skin Res. Technol. 25(3), 283-288 (2019). [10] O. Rangel, I. Arias, E. García, and S. Lopez-Padilla, “Topical tretinoin 0.1% for pregnancy-related abdominal striae: an open-label, multicenter, prospective study,” Adv. Ther. 18(4), 181-186 (2001). [11] D. Hexsel, M. Soirefmann, M. D. Porto, J. Schilling‐Souza, C. Siega, and T. Dal'Forno, “Superficial dermabrasion versus topical tretinoin on early striae distensae: a randomized, pilot study,” Dermatol. Surg. 40(5), 537-544 (2014). [12] P. Deprez, “Easy Peel for the Treatment of Stretch Marks,” Int. J. Cosmet. Surg. Aesthet. Dermatol. 2(3), 201-204 (2002). [13] S. Bitencourt, A. Lunardelli, R. H. Amaral, H. B. Dias, E. S. Boschi, and J. R. de Oliveira, “Safety and patient subjective efficacy of using galvanopuncture for the treatment of striae distensae,” J. Cosmet Dermatol. 15(4), 393-398 (2016). [14] A. S. Aldahan, V. V. Shah, S. Mlacker, S. Samarkandy, M. Alsaidan, and K Nouri, “Laser and light treatments for striae distensae: a comprehensive review of the literature,” Am. J. Clin. Dermatol. 17(3), 239-256 (2016). [15] M. Bleve, P. Capra, F. Pavanetto, and P. Perugini, “Ultrasound and 3D skin imaging: Methods to evaluate efficacy of striae distensae treatment,” Dermatol. Res. Pract. 2012, (2012). [16] D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, and C. A. Puliafito, “Optical Coherence Tomography,” Sci. New Ser. 254(5035), 1178–1181 (1991). [17] M. C. Pierce, J. Strasswimmer, B. H. Park, B. Cense, and J. F. De Boer, “Advances in Optical Coherence Tomography Imaging for Dermatology,” J. Invest. Dermatol. 123(3), 458-463 (2004). [18] M. R. Hee, E. A. Swanson, J. G. Fujimoto, and D. Huang, “Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging,” J. Opt. Soc. Am. B 9(6), 903-908 (1992). [19] M. J. Everett, K. Schoenenberger, B. W. Colston, and L. B. Da Silva, “Birefringence characterization of biological tissue by use of optical coherence tomography,” Opt. Lett. 23(3), 228-230 (1998). [20] C. Hitzenberger, E. Goetzinger, M. Sticker, M. Pircher, and A. Fercher, “Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography,” Opt. Express 9(13), 780-790 (2001). [21] M. Pircher, C. K. Hitzenberger, and U. Schmidt-Erfurth, “Polarization sensitive optical coherence tomography in the human eye,” Prog. Retin. Eye Res. 30(6), 431–451 (2011). [22] J. Walther, J. Golde, L. Kirsten, F. Tetschke, F. Hempel, T. Rosenauer, C. Hannig, and E. Koch, “In vivo imaging of human oral hard and soft tissues by polarization-sensitive optical coherence tomography,” J. Biomed. Opt. 22(12), 121717 (2017). [23] B. Baumann, “Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications,” Appl. Sci. 7(5), 474 (2017). [24] M. K. Al-Qaisi, and T. Akkin, “Polarization-sensitive optical coherence tomography based on polarization-maintaining fibers and frequency multiplexing,” Opt. Express 16(17), 13032–13041 (2008). [25] Z. Lu, D. Kasaragod, and S. J. Matcher, “Conical scan polarization-sensitive optical coherence tomography,” Biomed. Opt. Express 5(3), 752–762 (2014). [26] R. Byers, and S. Matcher, “Attenuation of stripe artifacts in optical coherence tomography images through wavelet-FFT filtering,” Biomed. Opt. Express 10(8), 4179-4189 (2019). [27] E. Götzinger, M. Pircher, W. Geitzenauer, C. Ahlers, B. Baumann, S. Michels, U. Schmidt-Erfurth, and C. K. Hitzenberger, \"Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography,\" Opt. Express 16(21), 16410-16422 (2008). [28] L. Chin, X. Yang, R. A. McLaughlin, P. B. Noble, and D. D. Sampson, \"En face parametric imaging of tissue birefringence using polarization-sensitive optical coherence tomography,\" J. Biomed. Opt. 18(6), 066005 (2013). [29] P. Zheng, R.M. Lavker, and A.M. Kligman, “Anatomy of striae,” Br. J. Dermatol. 112(2), 185-193 (1985). [30] S. Makita, M. Yamanari, and Y. Yasuno, \"Generalized Jones matrix optical coherence tomography: performance and local birefringence imaging,\" Opt. Express 18, 854-876 (2010). [31] M. E. H. Jaspers, F. Feroldi, M. Vlig, J. F. de Boer, and P. P. M. van Zuijlen, \"In vivo polarization-sensitive optical coherence tomography of human burn scars: birefringence quantification and correspondence with histologically determined collagen density,\" J. Biomed. Opt. 22(12), 121712 (2017). [32] S. G. Adie, T. R. Hillman, and D. D. Sampson, \"Detection of multiple scattering in optical coherence tomography using the spatial distribution of Stokes vectors,\" Opt. Express 15, 18033-18049 (2007). [33] P. Gong, L. Chin, S. Es’haghian, Y. M. Liew, F. M. Wood, D. D. Sampson, and R. A. McLaughlin, \"Imaging of skin birefringence for human scar assessment using polarization-sensitive optical coherence tomography aided by vascular masking,\" J. Biomed. Opt. 19(12), 126014 (2014). [1] E. O’Sullivan and A. Milosevic, “UK National Clinical Guidelines in Paediatric Dentistry: diagnosis, prevention and management of dental erosion,” Int. J. Paediatr. Dent. 18, 29–38 (2008). [2] O. Fejerskov, B. Nyvad, E.A. Kidd, “Dental caries: The disease and its clinical management,” Oxford, Blackwell Munksgaard 2, 20-48 (2008). [3] A. C. Sosa, J. M. Solis, N. Cruz-Fierro, S. López, and S. Nakagoshi, “Dental Erosion: Causes, diagnostics and treatment.,” J. Oral Res. 3(4), 257–261 (2014). [4] C. H. Wilder-Smith, P. Wilder-Smith, H. Kawakami-Wong, J. Voronets, K. Osann, and A. Lussi, “Quantification of Dental Erosions in Patients With GERD Using Optical Coherence Tomography Before and After Double-Blind, Randomized Treatment With Esomeprazole or Placebo,” Am. J. Gastroenterol. 104(11), 2788–2795 (2009). [5] K. H. Chan, A. C. Chan, C. L. Darling, and D. Fried, “Methods for monitoring erosion using optical coherence tomography,” Lasers in Dentistry XIX, International Society for Optics and Photonics 8566, 856606 (2013). [6] K. H. Chan, H. Tom, and D. Fried, “Monitoring the inhibition of erosion by a CO laser with OCT,” Lasers in Dentistry XX, International Society for Optics and Photonics 8929, 89290F (2014). [7] K. H. Chan, H. Tom, C. L. Darling, and D. Fried, “A method for monitoring enamel erosion using laser irradiated surfaces and optical coherence tomography,” Lasers Surg. Med. 46(9), 672–678 (2014). [8] M. C. D. de Moraes, A. Z. Freitas, and A. C. C. Aranha, “Progression of erosive lesions after Nd:YAG laser and fluoride using optical coherence tomography,” Lasers Med. Sci. 32(1), 1–8 (2017). [9] M. C. Huysmans, A. Young, and C. Ganss, “The role of fluoride in erosion therapy,” Erosive Tooth Wear, Karger Publishers 25, 230-243 (2014). [10] M. A. R. Buzalaf, A. C. Magalhães, and A. Wiegand, “Alternatives to fluoride in the prevention and treatment of dental erosion,” Erosive Tooth Wear, Karger Publishers 25, 244-252 (2014). [11] X. Wang, B. Megert, E. Hellwig, K. W. Neuhaus, and A. Lussi, “Preventing erosion with novel agents,” J. Dent. 39(2), 163–170 (2011). [12] A. Wiegand and T. Attin, “Randomised in situ trial on the effect of milk and CPP-ACP on dental erosion,” J. Dent. 42(9), 1210–1215 (2014). [13] S. Ranjitkar, J. A. Kaidonis, L. C. Richards, and G. C. Townsend, “The effect of CPP–ACP on enamel wear under severe erosive conditions,” Arch. Oral Biol. 54(6), 527–532 (2009). [14] S. Ranjitkar, J. M. Rodriguez, J. A. Kaidonis, L. C. Richards, G. C. Townsend, and D. W. Bartlett, “The effect of casein phosphopeptide–amorphous calcium phosphate on erosive enamel and dentine wear by toothbrush abrasion,” J. Dent. 37(4), 250–254 (2009). [15] A.M.A. Maia, C. Longbottom, A.S.L. Gomes, and J.M. Girkin, “Enamel erosion and prevention efficacy characterized by confocal laser scanning microscope,” Microsc. Res. Tech. 77, 439–45 (2014). [16] R. Kilano, “The effect of Stannous-containing fluoride toothpaste and Tooth Mousse in the prevention of dental erosion: an in-vitro study using Optical Coherence Tomography”, The University of Sheffield, 2018. [17] R. Byers, and S. Matcher, “Attenuation of stripe artifacts in optical coherence tomography images through wavelet-FFT filtering,” Biomed. Opt. Express 10(8), 4179-4189 (2019). [1] S. A. R. Mousavi, A. Chauvin, F. Pascaud, S. Kellenberger, and E. E. Farmer, “Glutamate receptor-like genes mediate leaf-to-leaf wound signalling,” Nature 500(7463), 422–426 (2013). [2] E. E. Farmer, D. Gasperini, and I. F. Acosta, “The squeeze cell hypothesis for the activation of jasmonate synthesis in response to wounding,” New Phytol. 204(2), 282–288 (2014). [3] J. Boadi, \"Clinical applications of ultra-high resolution and phase-sensitive optical coherence tomography,\" University of Sheffield (2016). [4] J. Williams, W. C. Lin, W. Li, S. Wang, S. J. Matcher, and A. A. Chauvet, \"Translating Optical Coherence Tomography Technologies from Clinical Studies to Botany: Real Time Imaging of Long-Distance Signaling in Plants,\" Optical Coherence Tomography, Optical Society of America, OM4E-6 (2020). [1] H.C. Flemming, G. Schaule, T. Griebe, J. Schmitt, and A. Tamachkiarowa, “Biofouling—the Achilles heel of membrane processes,” Desalination, 113(2-3), 215-225 (1997). [2] C. Dreszer, A. D. Wexler, S. Drusová, T. Overdijk, A. Zwijnenburg, H.-C. Flemming, J. C. Kruithof, and J. S. Vrouwenvelder, “In-situ biofilm characterization in membrane systems using Optical Coherence Tomography: Formation, structure, detachment and impact of flux change,” Water Res. 67, 243–254 (2014). [3] S. Chellam, J.G. Jacangelo, T.P. Bonacquisti, and B.A. Schauer, “Effect of pretreatment on surface water nanofiltration,” J. Am. Water Work. Assoc. 89(10), 77-89 (1997). [4] M. Wagner, and H. Horn, “Optical coherence tomography in biofilm research: a comprehensive review,” Biotechnol. Bioeng. 114(7), 1386-1402 (2017). [5] M. Piculell, C. Suarez, C. Li, M. Christensson, F. Persson, M. Wagner, M. Hermansson, K. Jönsson, and T. Welander, “The inhibitory effects of reject water on nitrifying populations grown at different biofilm thickness,” Water Res. 104, 292-302 (2016). [6] M. Wagner, D. Taherzadeh, C. Haisch, and H. Horn, “Investigation of the mesoscale structure and volumetric features of biofilms using optical coherence tomography,” Biotechnol. Bioeng. 107(5), 844-853 (2010). [7] P. Deines, R. Sekar, P.S. Husband, J.B. Boxall, A.M. Osborn, and C.A. Biggs, “A new coupon design for simultaneous analysis of in situ microbial biofilm formation and community structure in drinking water distribution systems,” Appl. Microbiol. Biotechnol. 87(2), 749-756 (2010). [8] K.E. Fish, and J.B. Boxall, “Biofilm microbiome (re)growth dynamics in drinking water distribution systems are impacted by chlorine concentration,” Front. Microbiol. 9, 2519 (2018). [9] F.C. Pick, K.E. Fish, and J.B. Boxall, “Assimilable organic carbon cycling within drinking water distribution systems,” Water Res. 198, 117147 (2021)."],"dcterms:accessrights":["public"],"dc:title":["Development and Applications of Near- and Mid-infrared OCT"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000212613125"]},"updated_at":"2026-11-18T23:21:14Z"}