{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:32404"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:32404","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Intelligent feature analysis of FDG PET-CT images for more accurate diagnosis in large vessel vasculitis","abstract":"Aortitis refers to inflammatory conditions affecting the aortic wall that cannot be explained by atherosclerosis alone. Large Vessel Vasculitis (LVV) is the main type of non-infectious aortitis and can affect any of the large arteries. Aortitis and LVV are difficult to diagnose and treat due to a variety of reasons such as non-specific symptoms and diagnostic tests, a large number of potential causes, and risks involved in providing incorrect or delayed treatment. [18F]-Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET-CT) imaging plays a key role in diagnosis of LVV due to its ability to detect inflammation early and non-invasively, but is mostly assessed qualitatively making its interpretation vulnerable to bias and inter-observer variation. Therefore, there is a need for more reliable imaging biomarkers which can be achieved with radiomic analysis. The aim of this thesis is to explore the diagnostic ability of radiomic features in FDG PET-CT imaging of aortitis. First, the feasibility is determined and a methodological pipeline established. Next, the findings are validated with data from multiple centres and the overall method automated. The first step of the method is the aortic segmentation using an artificial intelligence which produces similar radiomic features as the manual segmentation. When used as input in the diagnostic models, several individual radiomic features and groups of radiomic features demonstrated high diagnostic performance across the training, test and validation cohorts. In particular features based on heterogeneity perform well. The method displayed good generalizability and transferability which is important prerequisites for clinical use. These findings could be used to build an automated clinical decision tool which would facilitate objective and standardized assessment regardless of observer experience.","abstract_html":"Aortitis refers to inflammatory conditions affecting the aortic wall that cannot be explained by atherosclerosis alone. Large Vessel Vasculitis (LVV) is the main type of non-infectious aortitis and can affect any of the large arteries. Aortitis and LVV are difficult to diagnose and treat due to a variety of reasons such as non-specific symptoms and diagnostic tests, a large number of potential causes, and risks involved in providing incorrect or delayed treatment. [18F]-Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET-CT) imaging plays a key role in diagnosis of LVV due to its ability to detect inflammation early and non-invasively, but is mostly assessed qualitatively making its interpretation vulnerable to bias and inter-observer variation. Therefore, there is a need for more reliable imaging biomarkers which can be achieved with radiomic analysis. The aim of this thesis is to explore the diagnostic ability of radiomic features in FDG PET-CT imaging of aortitis. First, the feasibility is determined and a methodological pipeline established. Next, the findings are validated with data from multiple centres and the overall method automated. The first step of the method is the aortic segmentation using an artificial intelligence which produces similar radiomic features as the manual segmentation. When used as input in the diagnostic models, several individual radiomic features and groups of radiomic features demonstrated high diagnostic performance across the training, test and validation cohorts. In particular features based on heterogeneity perform well. The method displayed good generalizability and transferability which is important prerequisites for clinical use. These findings could be used to build an automated clinical decision tool which would facilitate objective and standardized assessment regardless of observer experience.","abstract_has_math":false,"creators":["Duff, Lisa Mairi"],"institution":"University of Leeds","degree_name":"Integrated Ph.D and Master","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Scarsbrook, Andrew F","Mackie, Sarah L","Bailey, Marc A","Morgan, Ann W","Tsoumpas, Charalampos"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-11","date_published":"2022-11","updated_at":"2026-11-18T23:21:28Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.878045"],"render_values":[{"text":"uk.bl.ethos.878045","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/L014823/1"],"render_values":[{"text":"EP/L014823/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000242956356"],"render_values":[{"text":"0000-0002-4295-6356","href":"https://orcid.org/0000-0002-4295-6356","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/32404/1/Thesis%20%288%29.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A32404","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Scarsbrook, Andrew F","Mackie, Sarah L","Bailey, Marc A","Morgan, Ann W","Tsoumpas, Charalampos"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC"]},{"key":"dc:creator","label":"Author","values":["Duff, Lisa Mairi"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000242956356"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-11"]},{"key":"dc:date.issued","label":"Date","values":["2022-11"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Mechanical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/32404/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. . Pugh D, Grayson P, Basu N, and Dhaun N. Aortitis: recent advances, current con�cepts and future possibilities. Heart 2021;107:1620–9. 2. Parikh M, Miller NR, Lee AG, Savino PJ, Vacarezza MN, Cornblath W, Eggen�berger E, Antonio-Santos A, Golnik K, Kardon R, et al. Prevalence of a normal C�reactive protein with an elevated erythrocyte sedimentation rate in biopsy-proven giant cell arteritis. Ophthalmology 2006;113:1842–5. 3. Monach PA. Biomarkers in vasculitis. Current opinion in rheumatology 2014;26:24. 4. Gornik HL and Creager MA. Aortitis. Circulation 2008;117:3039–51. 5. Stone JR, Bruneval P, Angelini A, Bartoloni G, Basso C, Batoroeva L, Buja LM, Butany J, d’Amati G, Fallon JT, et al. Consensus statement on surgical pathology of the aorta from the Society for Cardiovascular Pathology and the Association for European Cardiovascular Pathology: I. Inflammatory diseases. Cardiovascular Pathology 2015;24:267–78. 6. Marvisi C, Buttini EA, and Vaglio A. Aortitis and periaortitis: the puzzling spec�trum of inflammatory aortic diseases. La Presse Medicale 2020;49:104018. ´ 7. Monti S, Agueda AF, Luqmani RA, Buttgereit F, Cid M, Dejaco C, Mahr A, Ponte ´ C, Salvarani C, Schmidt W, et al. Systematic literature review informing the 2018 update of the EULAR recommendation for the management of large vessel vas�culitis: focus on giant cell arteritis. RMD open 2019;5:e001003. 121 122 8. Wallace ZS, Zhang Y, Perugino CA, Naden R, Choi HK, and Stone JH. Clin�ical phenotypes of IgG4-related disease: an analysis of two international cross�sectional cohorts. Annals of the rheumatic diseases 2019;78:406–12. 9. Peng L, Zhang P, Li J, Liu Z, Lu H, Zhu L, Wang X, Teng F, Li X, Guo H, et al. IgG4-related aortitis/periaortitis and periarteritis: a distinct spectrum of IgG4- related disease. Arthritis Research & Therapy 2020;22:1–11. 10. Horton B. An undescribed form of arteritis of temporal vessels. Proc Staff Mayo Clin Proc 1932;7:700–1. 11. Muratore F, Kermani TA, Crowson CS, Green AB, Salvarani C, Matteson EL, and Warrington KJ. Large-vessel giant cell arteritis: a cohort study. Rheumatology 2015;54:463–70. 12. Koster MJ, Matteson EL, and Warrington KJ. Large-vessel giant cell arteritis: di�agnosis, monitoring and management. Rheumatology 2018;57:ii32–ii42. 13. Kebed DT, Bois JP, Connolly HM, Scott CG, Bowen JM, Warrington KJ, Makol A, Greason KL, Schaff HV, and Anavekar NS. Spectrum of aortic disease in the giant cell arteritis population. The American Journal of Cardiology 2018;121:501– 8. 14. Dejaco C, Ramiro S, Duftner C, Besson FL, Bley TA, Blockmans D, Brouwer E, Cimmino MA, Clark E, Dasgupta B, et al. EULAR recommendations for the use of imaging in large vessel vasculitis in clinical practice. Annals of the rheumatic diseases 2018;77:636–43. 15. Salvarani C, Cantini F, and Hunder GG. Polymyalgia rheumatica and giant-cell arteritis. The Lancet 2008;372:234–45. 16. Maksimowicz-McKinnon K, Clark TM, and Hoffman GS. Takayasu arteritis and giant cell arteritis: a spectrum within the same disease? Medicine 2009;88:221–6. 17. Gonzalez-Gay MA, Garcıa-Porr ´ ua C, Llorca J, Hajeer AH, Bra ´ nas F, Dababneh ˜ A, Gonzalez-Louzao C, Rodriguez-Gil E, Rodrıguez-Ledo P, and Ollier W. Visual ´ manifestations of giant cell arteritis. Trends and clinical spectrum in 161 patients. Medicine 2000;79:283–92. 123 18. Gonzalez-Gay MA, Barros S, Lopez-Diaz MJ, Garcia-Porrua C, Sanchez-Andrade A, and Llorca J. Giant cell arteritis: disease patterns of clinical presentation in a series of 240 patients. Medicine 2005;84:269–76. 19. Robson JC, Kiran A, Maskell J, Hutchings A, Arden N, Dasgupta B, Hamilton W, Emin A, Culliford D, and Luqmani RA. The relative risk of aortic aneurysm in patients with giant cell arteritis compared with the general population of the UK. Annals of the rheumatic diseases 2015;74:129–35. 20. Richards BL, March L, and Gabriel SE. Epidemiology of large-vessel vasculidities. Best Practice & Research Clinical Rheumatology 2010;24:871–83. 21. Zaldivar Villon ML, Rocha JAL de la, and Espinoza LR. Takayasu arteritis: recent developments. Current Rheumatology Reports 2019;21:1–10. 22. Goel R, Chandan JS, Thayakaran R, Adderley NJ, Nirantharakumar K, and Harper L. Cardiovascular and renal morbidity in Takayasu arteritis: a Population-Based retrospective cohort study from the United Kingdom. Arthritis & Rheumatology 2021;73:504–11. 23. Petri H, Nevitt A, Sarsour K, Napalkov P, and Collinson N. Incidence of giant cell arteritis and characteristics of patients: data-driven analysis of comorbidities. Arthritis care & research 2015;67:390–5. 24. Sharma A, Mohammad AJ, and Turesson C. Incidence and prevalence of giant cell arteritis and polymyalgia rheumatica: a systematic literature review. In: Seminars in Arthritis and Rheumatism. Vol. 50. 5. Elsevier. 2020:1040–8. 25. Watts R, Al-Taiar A, Mooney J, Scott D, and MacGregor A. The epidemiology of Takayasu arteritis in the UK. Rheumatology 2009;48:1008–11. 26. Clifford AH, Arafat A, Idrees JJ, Roselli EE, Tan CD, Rodriguez ER, Svensson LG, Blackstone E, Johnston D, Pettersson G, et al. Outcomes among 196 patients with noninfectious proximal aortitis. Arthritis & Rheumatology 2019;71:2112–20. 27. Ferfar Y, Morinet S, Espitia O, Agard C, Vautier M, Comarmond C, Desbois AC, Domont F, Fouret PJ, Redheuil A, et al. Long-Term outcome and prognosis factors of isolated aortitis. Circulation 2020;142:92–4. 124 28. Tomasson G, Peloquin C, Mohammad A, Love TJ, Zhang Y, Choi HK, and Merkel PA. Risk for cardiovascular disease early and late after a diagnosis of giant-cell arteritis: a cohort study. Annals of internal medicine 2014;160:73–80. 29. Koster MJ, Warrington KJ, and Matteson EL. Morbidity and mortality of large�vessel vasculitides. Current rheumatology reports 2020;22:1–13. 30. Buttgereit F, Matteson EL, Dejaco C, and Dasgupta B. Prevention of glucocorti�coid morbidity in giant cell arteritis. Rheumatology 2018;57:ii11–ii21. 31. Foote EA, Postier RG, Greenfield RA, and Bronze MS. Infectious aortitis. Current Treatment Options in Cardiovascular Medicine 2005;7:89–97. 32. Barra L, Pope JE, Pequeno P, Gatley JM, and Widdifield J. Increased mortality for individuals with Giant Cell Arteritis: a population-based study. Arthritis Care & Research 2021. 33. Therkildsen P, Nielsen BD, Thurah A de, Hansen IT, Nørgaard M, and Hauge EM. All-cause and cause-specific mortality in patients with giant cell arteritis: a nationwide, population-based cohort study. Rheumatology 2022;61:1195–203. 34. Hill CL, Black RJ, Nossent JC, Ruediger C, Nguyen L, Ninan JV, and Lester S. Risk of mortality in patients with giant cell arteritis: a systematic review and meta�analysis. In: Seminars in arthritis and rheumatism. Vol. 46. 4. Elsevier. 2017:513– 9. 35. Uddhammar A, Eriksson AL, Nystrom L, Stenling R, and Rantap ¨ a¨a-Dahlqvist S. ¨ Increased mortality due to cardiovascular disease in patients with giant cell arteritis in northern Sweden. The Journal of Rheumatology 2002;29:737–42. 36. Muratore F, Pipitone N, and Salvarani C. Standard and biological treatment in large vessel vasculitis: guidelines and current approaches. Expert review of clinical immunology 2017;13:345–60. 37. Hellmich B, Agueda A, Monti S, Buttgereit F, De Boysson H, Brouwer E, Cassie R, Cid MC, Dasgupta B, Dejaco C, et al. 2018 Update of the EULAR recom�mendations for the management of large vessel vasculitis. Annals of the rheumatic diseases 2020;79:19–30. 125 38. Wilson JC, Sarsour K, Collinson N, Tuckwell K, Musselman D, Klearman M, Na�palkov P, Jick SS, Stone JH, and Meier CR. Serious adverse effects associated with glucocorticoid therapy in patients with giant cell arteritis (GCA): a nested case–control analysis. In: Seminars in arthritis and rheumatism. Vol. 46. 6. Else�vier. 2017:819–27. 39. Wu J, Keeley A, Mallen C, Morgan AW, and Pujades-Rodriguez M. Incidence of infections associated with oral glucocorticoid dose in people diagnosed with polymyalgia rheumatica or giant cell arteritis: a cohort study in England. Cmaj 2019;191:E680–E688. 40. Wu J, Mackie SL, and Pujades-Rodriguez M. Glucocorticoid dose-dependent risk of type 2 diabetes in six immune-mediated inflammatory diseases: a population�based cohort analysis. BMJ Open Diabetes Research and Care 2020;8:e001220. 41. Pujades-Rodriguez M, Morgan AW, Cubbon RM, and Wu J. Dose-dependent oral glucocorticoid cardiovascular risks in people with immune-mediated inflammatory diseases: A population-based cohort study. PLoS medicine 2020;17:e1003432. 42. Stone JH, Tuckwell K, Dimonaco S, Klearman M, Aringer M, Blockmans D, Brouwer E, Cid MC, Dasgupta B, Rech J, et al. Trial of tocilizumab in giant-cell arteritis. New England Journal of Medicine 2017;377:317–28. 43. Chang HW, Kim SH, Hakim AR, Chung S, Kim DJ, Lee JH, Kim JS, Lim C, and Park KH. Diameter and growth rate of the thoracic aorta—analysis based on serial computed tomography scans. Journal of Thoracic Disease 2020;12:4002. 44. Mensel B, Quadrat A, Schneider T, Kuhn JP, D ¨ orr M, V ¨ olzke H, Lieb W, Hegen- ¨ scheid K, and Lorbeer R. MRI-based determination of reference values of thoracic aortic wall thickness in a general population. European radiology 2014;24:2038– 44. 45. Choe YH, Han BK, Koh EM, Kim DK, Do YS, and Lee WR. Takayasu’s arteri�tis: assessment of disease activity with contrast-enhanced MR imaging. American Journal of Roentgenology 2000;175:505–11. 126 46. Tso E, Flamm SD, White RD, Schvartzman PR, Mascha E, and Hoffman GS. Takayasu arteritis: utility and limitations of magnetic resonance imaging in di�agnosis and treatment. Arthritis & Rheumatism: Official Journal of the American College of Rheumatology 2002;46:1634–42. 47. Besutti G, Muratore F, Mancuso P, Ferrari M, Galli E, Spaggiari L, Monelli F, Casali M, Versari A, Boiardi L, et al. Vessel inflammation and morphological changes in patients with large vessel vasculitis: a retrospective study. RMD open 2022;8:e001977. 48. Muto G, Yamashita H, Takahashi Y, Miyata Y, Morooka M, Minamimoto R, Kubota K, Kaneko H, Kano T, and Mimori A. Large vessel vasculitis in elderly patients: early diagnosis and steroid-response evaluation with FDG-PET/CT and contrast-enhanced CT. Rheumatology international 2014;34:1545–54. 49. Quinn KA, Ahlman MA, Alessi HD, LaValley MP, Neogi T, Marko J, Novakovich E, and Grayson PC. Association of 18F-Fluorodeoxyglucose Positron Emission Tomography and Angiographic Progression of Disease in Large-Vessel Vasculitis. Arthritis & Rheumatology 2022. 50. Nienhuis PH, Praagh GD van, Glaudemans AW, Brouwer E, and Slart RH. A re�view on the value of imaging in differentiating between large vessel vasculitis and atherosclerosis. Journal of personalized medicine 2021;11:236. 51. Planas-Rigol E, Corbera-Bellalta M, Espıgol-Frigole G, Terrades-Garcia N, Alba ´ M, et al. Giant-Cell Arteritis: Immunopathogenic Mechanisms Involved in Vascu�lar Inflammation and Remodeling. J Vasc 1: 103. doi: 10.4172/2471-9544.100103 Page 2 of 7 J Vasc ISSN: 2471-9544 JOV, an open access journal Volume 1• Issue 2• 100103. dose glucocorticoids, neutrophils have lower membrane expression of integrin CD11b, are less adhesive to endothelial cells and are able to suppress T cell proliferation. These abnormalities revert when 2016:3. 52. Gajree S, Borooah S, Dhillon N, Goudie C, Smith C, Aspinall P, and Dhillon B. Temporal artery biopsies in south-east Scotland: a five year review. The Journal of the Royal College of Physicians of Edinburgh 2017;47:124–8. 127 53. Slart RH et al. FDG-PET/CT (A) imaging in large vessel vasculitis and polymyal�gia rheumatica: joint procedural recommendation of the EANM, SNMMI, and the PET Interest Group (PIG), and endorsed by the ASNC. European journal of nuclear medicine and molecular imaging 2018;45:1250–69. 54. Slart RH, Glaudemans AW, Gheysens O, Lubberink M, Kero T, Dweck MR, Habib G, Gaemperli O, Saraste A, Gimelli A, et al. Procedural recommendations of car�diac PET/CT imaging: standardization in inflammatory-, infective-, infiltrative-, and innervation (4Is)-related cardiovascular diseases: a joint collaboration of the EACVI and the EANM. European Journal of Nuclear Medicine and Molecular Imaging 2020:1–24. 55. Ehman EC, Johnson GB, Villanueva-Meyer JE, Cha S, Leynes AP, Larson PEZ, and Hope TA. PET/MRI: where might it replace PET/CT? Journal of Magnetic Resonance Imaging 2017;46:1247–62. 56. Basu S, Kwee TC, Surti S, Akin EA, Yoo D, and Alavi A. Fundamentals of PET and PET/CT imaging. Annals of the New York Academy of Sciences 2011;1228:1– 18. 57. Levin CS and Hoffman EJ. Calculation of positron range and its effect on the fun�damental limit of positron emission tomography system spatial resolution. Physics in Medicine & Biology 1999;44:781. 58. Conti M and Eriksson L. Physics of pure and non-pure positron emitters for PET: a review and a discussion. EJNMMI physics 2016;3:1–17. 59. Schmitz RE, Alessio AM, Kinahan PE, Mason NS, and Lin EC. The physics of PET/Ct scanners. PET and PET/CT: a clinical guide 2005;3. 60. Berger A. How does it work?: Positron emission tomography. BMJ: British Medi�cal Journal 2003;326:1449. 61. Humm JL, Rosenfeld A, and Del Guerra A. From PET detectors to PET scanners. European journal of nuclear medicine and molecular imaging 2003;30:1574–97. 128 62. Moses WW. Fundamental limits of spatial resolution in PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detec�tors and Associated Equipment 2011;648:S236–S240. 63. Rapisarda E, Bettinardi V, Thielemans K, and Gilardi M. Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET. Physics in medicine & biology 2010;55:4131. 64. Slomka PJ, Pan T, Berman DS, and Germano G. Advances in SPECT and PET hardware. Progress in Cardiovascular Diseases 2015;57:566–78. 65. Surti S and Karp JS. Update on latest advances in time-of-flight PET. Physica Medica 2020;80:251–8. 66. Slomka PJ, Pan T, and Germano G. Recent advances and future progress in PET instrumentation. In: Seminars in nuclear medicine. Vol. 46. 1. Elsevier. 2016:5–19. 67. Bailey DL and Meikle SR. A convolution-subtraction scatter correction method for 3D PET. Physics in Medicine & Biology 1994;39:411. 68. Levin CS, Dahlbom M, and Hoffman EJ. A Monte Carlo correction for the effect of Compton scattering in 3-D PET brain imaging. IEEE transactions on nuclear science 1995;42:1181–5. 69. Watson CC, Newport D, and Casey ME. A single scatter simulation technique for scatter correction in 3D PET. Three-dimensional image reconstruction in radiology and nuclear medicine 1996:255–68. 70. Ollinger JM. Model-based scatter correction for fully 3D PET. Physics in Medicine & Biology 1996;41:153. 71. Polycarpou I, Thielemans K, Manjeshwar R, Aguiar P, Marsden PK, and Tsoumpas C. Comparative evaluation of scatter correction in 3D PET using different scatter�level approximations. Annals of nuclear medicine 2011;25:643–9. 72. Brasse D, Kinahan PE, Lartizien C, Comtat C, Casey M, and Michel C. Correction methods for random coincidences in fully 3D whole-body PET: impact on data and image quality. Journal of nuclear medicine 2005;46:859–67. 129 73. Słomski A, Rudy Z, Bednarski T, Białas P, Czerwinski E, Kapłon Ł, Kochanowski ´ A, Korcyl G, Kowal J, Kowalski P, et al. 3D PET image reconstruction based on the maximum likelihood estimation method (MLEM) algorithm. Bio-Algorithms and Med-Systems 2014;10:1–7. 74. Shepp LA and Vardi Y. Maximum likelihood reconstruction for emission tomog�raphy. IEEE transactions on medical imaging 1982;1:113–22. 75. Miller TR and Wallis JW. Clinically important characteristics of maximum-likelihood reconstruction. Journal of Nuclear Medicine 1992;33:1678–84. 76. Boellaard R, Van Lingen A, and Lammertsma AA. Experimental and clinical eval�uation of iterative reconstruction (OSEM) in dynamic PET: quantitative character�istics and effects on kinetic modeling. Journal of Nuclear Medicine 2001;42:808– 17. 77. Hudson HM and Larkin RS. Accelerated image reconstruction using ordered sub�sets of projection data. IEEE transactions on medical imaging 1994;13:601–9. 78. Bettinardi V, Presotto L, Rapisarda E, Picchio M, Gianolli L, and Gilardi M. Physical Performance of the new hybrid PET/CT Discovery-690. Medical physics 2011;38:5394–411. 79. Aide N, Lasnon C, Kesner A, Levin CS, Buvat I, Iagaru A, Hermann K, Badawi RD, Cherry SR, Bradley KM, et al. New PET technologies–embracing progress and pushing the limits. European journal of nuclear medicine and molecular imag�ing 2021;48:2711–26. 80. Hatt M, Le Rest CC, Tixier F, Badic B, Schick U, and Visvikis D. Radiomics: data are also images. Journal of Nuclear Medicine 2019;60:38S–44S. 81. Lee JS. A review of deep-learning-based approaches for attenuation correction in positron emission tomography. IEEE Transactions on Radiation and Plasma Med�ical Sciences 2020;5:160–84. 82. Reader AJ, Corda G, Mehranian A, Costa-Luis C da, Ellis S, and Schnabel JA. Deep learning for PET image reconstruction. IEEE Transactions on Radiation and Plasma Medical Sciences 2020;5:1–25. 130 83. Zhao YM, Li YH, Chen T, Zhang WG, Wang LH, Feng J, Li C, Zhang X, Fan W, and Hu YY. Image quality and lesion detectability in low-dose pediatric 18F�FDG scans using total-body PET/CT. European journal of nuclear medicine and molecular imaging 2021;48:3378–85. 84. Nadig V, Herrmann K, Mottaghy FM, and Schulz V. Hybrid total-body pet scan�ners—current status and future perspectives. European journal of nuclear medicine and molecular imaging 2022;49:445–59. 85. Van der Geest K, Treglia G, Glaudemans A, Brouwer E, Sandovici M, Jamar F, Gheysens O, and Slart R. Diagnostic value of [18F] FDG-PET/CT for treatment monitoring in large vessel vasculitis: a systematic review and meta-analysis. Euro�pean journal of nuclear medicine and molecular imaging 2021;48:3886–902. 86. Lodge MA. Repeatability of SUV in oncologic 18F-FDG PET. Journal of Nuclear Medicine 2017;58:523–32. 87. Praagh GD van, Nienhuis PH, Jong DM de, Reijrink M, Geest KSM van der, Brouwer E, Glaudemans AWJM, Sinha B, Willemsen ATM, and Slart RHJA. To�ward Reliable Uptake Metrics in Large Vessel Vasculitis Studies. Diagnostics 2021;11. 88. Wahl RL, Jacene H, Kasamon Y, and Lodge MA. From RECIST to PERCIST: evolving considerations for PET response criteria in solid tumors. Journal of nu�clear medicine 2009;50:122S–150S. 89. Schwartz J, Humm J, Gonen M, Kalaigian H, Schoder H, Larson S, and Nehmeh S. Repeatability of SUV measurements in serial PET. Medical physics 2011;38:2629– 38. 90. Fletcher J and Kinahan P. PET/CT standardized uptake values (SUVs) in clinical practice and assessing response to therapy. NIH Public Access 2010;31:496–505. 91. Adams MC, Turkington TG, Wilson JM, and Wong TZ. A systematic review of the factors affecting accuracy of SUV measurements. American Journal of Roentgenol�ogy 2010;195:310–20. 131 92. Eskian M, Alavi A, Khorasanizadeh M, Viglianti BL, Jacobsson H, Barwick TD, Meysamie A, Yi SK, Iwano S, Bybel B, et al. Effect of blood glucose level on standardized uptake value (SUV) in 18F-FDG PET-scan: a systematic review and meta-analysis of 20,807 individual SUV measurements. European journal of nu�clear medicine and molecular imaging 2019;46:224–37. 93. Iking J, Staniszewska M, Kessler L, Klose JM, Luckerath K, Fendler WP, Her- ¨ rmann K, and Rischpler C. Imaging inflammation with positron emission tomog�raphy. Biomedicines 2021;9:212. 94. Pelletier-Galarneau M and Ruddy TD. PET/CT for diagnosis and management of large-vessel vasculitis. Current cardiology reports 2019;21:34. 95. Nielsen BD, Hansen IT, Kramer S, Haraldsen A, Hjorthaug K, Bogsrud TV, Ejlersen JA, Stolle LB, Keller KK, Therkildsen P, et al. Simple dichotomous assessment of cranial artery inflammation by conventional 18F-FDG PET/CT shows high accu�racy for the diagnosis of giant cell arteritis: a case-control study. European Journal of Nuclear Medicine and Molecular Imaging 2019;46:184–93. 96. Patel PY, Dalal I, and Griffith B. [18F] FDG-PET Evaluation of Spinal Pathology in Patients in Oncology: Pearls and Pitfalls for the Neuroradiologist. American Journal of Neuroradiology 2022;43:332–40. 97. Lee SW, Kim SJ, Seo Y, Jeong SY, Ahn BC, and Lee J. F-18 FDG PET for as�sessment of disease activity of large vessel vasculitis: A systematic review and meta-analysis. Journal of Nuclear Cardiology 2019;26:59–67. 98. Veeranna V, Fisher A, Nagpal P, Ghosh N, Fisher E, Steigner M, Creager MA, Dorbala S, and Di Carli MF. Utility of multimodality imaging in diagnosis and follow-up of aortitis. Journal of Nuclear Cardiology 2016;23:590–5. 99. Vaidyanathan S, Patel C, Scarsbrook A, and Chowdhury F. FDG PET/CT in infec�tion and inflammation—current and emerging clinical applications. Clinical radi�ology 2015;70:787–800. 100. Chen Z, Liu M, Li L, and Chen L. Involvement of the Warburg effect in non-tumor diseases processes. Journal of cellular physiology 2018;233:2839–49. 132 101. Jacobson O, Kiesewetter DO, and Chen X. Fluorine-18 radiochemistry, labeling strategies and synthetic routes. Bioconjugate chemistry 2015;26:1–18. 102. Yu S. Review of 18F-FDG synthesis and quality control. Biomedical imaging and intervention journal 2006;2. 103. Fludeoxyglucose F 18 injection (FDG): Uses, dosage, side effects, interactions, warning. 2022. URL: https: // www. rxlist. com/fludeoxyglucose - drug. htm#indications. 104. Walter MA, Melzer RA, Schindler C, Muller-Brand J, Tyndall A, and Nitzsche EU. ¨ The value of [18 F] FDG-PET in the diagnosis of large-vessel vasculitis and the assessment of activity and extent of disease. European journal of nuclear medicine and molecular imaging 2005;32:674–81. 105. Nielsen BD, Gormsen LC, Hansen IT, Keller KK, Therkildsen P, and Hauge EM. Three days of high-dose glucocorticoid treatment attenuates large-vessel 18F-FDG uptake in large-vessel giant cell arteritis but with a limited impact on diagnostic ac�curacy. European journal of nuclear medicine and molecular imaging 2018;45:1119– 28. 106. Fuchs M, Briel M, Daikeler T, Walker UA, Rasch H, Berg S, Ng QK, Raatz H, Jayne D, Kotter I, et al. The impact of 18 F-FDG PET on the management of pa- ¨ tients with suspected large vessel vasculitis. European journal of nuclear medicine and molecular imaging 2012;39:344–53. 107. Stellingwerff MD, Brouwer E, Lensen KJD, Rutgers A, Arends S, Van Der Geest KS, Glaudemans AW, and Slart RH. Different scoring methods of FDG PET/CT in giant cell arteritis: need for standardization. Medicine 2015;94. 108. Grayson PC, Alehashemi S, Bagheri AA, Civelek AC, Cupps TR, Kaplan MJ, Malayeri AA, Merkel PA, Novakovich E, Bluemke DA, et al. 18F-fluorodeoxyglucose– positron emission tomography as an imaging biomarker in a prospective, longi�tudinal cohort of patients with large vessel vasculitis. Arthritis & Rheumatology 2018;70:439–49. 133 109. Kang F, Han Q, Zhou X, Zheng Z, Wang S, Ma W, Zhang K, Quan Z, Yang W, Wang J, et al. Performance of the PET vascular activity score (PETVAS) for qual�itative and quantitative assessment of inflammatory activity in Takayasu’s arteritis patients. European journal of nuclear medicine and molecular imaging 2020:1–11. 110. Quinn KA, Dashora H, Novakovich E, Ahlman MA, and Grayson PC. Use of 18F�fluorodeoxyglucose positron emission tomography to monitor tocilizumab effect on vascular inflammation in giant cell arteritis. Rheumatology 2021;60:4384–9. 111. Mackie SL, Dejaco C, Appenzeller S, Camellino D, Duftner C, Gonzalez-Chiappe S, Mahr A, Mukhtyar C, Reynolds G, De Souza AWS, et al. British Society for Rheumatology guideline on diagnosis and treatment of giant cell arteritis. Rheuma�tology 2020;59:e1–e23. 112. Versari A, Pipitone N, Casali M, Jamar F, and Pazzola G. Use of imaging tech�niques in large vessel vasculitis and related conditions. The quarterly journal of nuclear medicine and molecular imaging: official publication of the Italian Asso�ciation of Nuclear Medicine (AIMN)[and] the International Association of Radio�pharmacology (IAR),[and] Section of the Society of 2018;62:34–9. 113. Grayson PC, Alehashemi S, Bagheri AA, Civelek AC, Cupps TR, Kaplan MJ, Malayeri AA, Merkel PA, Novakovich E, Bluemke DA, et al. Positron emission to�mography as an imaging biomarker in a prospective, longitudinal cohort of patients with large vessel vasculitis. Arthritis & rheumatology (Hoboken, NJ) 2018;70:439. 114. Dashora HR, Rosenblum JS, Quinn KA, Alessi H, Novakovich E, Saboury B, Ahlman MA, and Grayson P. Comparing semi-quantitative and qualitative meth�ods of vascular FDG-PET activity measurement in large-vessel vasculitis. Journal of Nuclear Medicine 2021. 115. Laffon E and Marthan R. On Semi-quantitative Methods for Assessing Vascular 18FDG-PET Activity in Large-Vessels Vasculitis. Journal of Nuclear Medicine 2021. 134 116. Dellavedova L, Carletto M, Faggioli P, Sciascera A, Del Sole A, Mazzone A, and Maffioli L. The prognostic value of baseline 18 F-FDG PET/CT in steroid-naıve large-vessel vasculitis: introduction of volume-based parameters. European journal of nuclear medicine and molecular imaging 2016;43:340–8. 117. Motwani M. Hiding beyond plain sight: Textural analysis of positron emission tomography to identify high-risk plaques in carotid atherosclerosis. 2019. 118. Hatt M, Le Rest CC, Antonorsi N, Tixier F, Tankyevych O, Jaouen V, Lucia F, Bourbonne V, Schick U, Badic B, et al. Radiomics in PET/CT: current status and future AI-based evolutions. In: Seminars in Nuclear Medicine. Vol. 51. 2. Elsevier. 2021:126–33. 119. Lambin P, Rios-Velazquez E, Leijenaar R, Carvalho S, Van Stiphout RG, Granton P, Zegers CM, Gillies R, Boellard R, Dekker A, et al. Radiomics: extracting more information from medical images using advanced feature analysis. European jour�nal of cancer 2012;48:441–6. 120. O’Sullivan F, Roy S, and Eary J. A statistical measure of tissue heterogeneity with application to 3D PET sarcoma data. Biostatistics 2003;4:433–48. 121. El Naqa I, Grigsby PW, Apte A, Kidd E, Donnelly E, Khullar D, Chaudhari S, Yang D, Schmitt M, Laforest R, et al. Exploring feature-based approaches in PET images for predicting cancer treatment outcomes. Pattern recognition 2009;42:1162–71. 122. Galavis PE, Hollensen C, Jallow N, Paliwal B, and Jeraj R. Variability of textural features in FDG PET images due to different acquisition modes and reconstruction parameters. Acta oncologica 2010;49:1012–6. 123. Strand R, Malmberg F, Johansson L, Lind L, Sundbom M, Ahlstrom H, and Kull- ¨ berg J. A concept for holistic whole body MRI data analysis, Imiomics. PloS one 2017;12:e0169966. 124. Visvikis D, Le Rest CC, Jaouen V, and Hatt M. Artificial intelligence, machine (deep) learning and radio (geno) mics: definitions and nuclear medicine imag�ing applications. European Journal of Nuclear Medicine and Molecular Imaging 2019:1–8. 135 125. Duff L and Tsoumpas C. Automated diagnosis and prediction in cardiovascular diseases using tomographic imaging. 126. Visvikis D, Lambin P, Beuschau Mauridsen K, Hustinx R, Lassmann M, Rischpler C, Shi K, and Pruim J. Application of artificial intelligence in nuclear medicine and molecular imaging: a review of current status and future perspectives for clinical translation. European journal of nuclear medicine and molecular imaging 2022:1– 12. 127. Zhuang F, Qi Z, Duan K, Xi D, Zhu Y, Zhu H, Xiong H, and He Q. A comprehen�sive survey on transfer learning. Proceedings of the IEEE 2020;109:43–76. 128. Shorten C and Khoshgoftaar TM. A survey on image data augmentation for deep learning. Journal of big data 2019;6:1–48. 129. Park JE, Park SY, Kim HJ, and Kim HS. Reproducibility and generalizability in radiomics modeling: possible strategies in radiologic and statistical perspectives. Korean journal of radiology 2019;20:1124–37. 130. Slart RH, Williams MC, Juarez-Orozco LE, Rischpler C, Dweck MR, Glaudemans AW, Gimelli A, Georgoulias P, Gheysens O, Gaemperli O, et al. Position paper of the EACVI and EANM on artificial intelligence applications in multimodality car�diovascular imaging using SPECT/CT, PET/CT, and cardiac CT. European journal of nuclear medicine and molecular imaging 2021;48:1399–413. 131. Lovinfosse P, Visvikis D, Hustinx R, and Hatt M. FDG PET radiomics: a review of the methodological aspects. Clinical and Translational Imaging 2018;6:379–91. 132. Ferreira M, Lovinfosse P, Hermesse J, Decuypere M, Rousseau C, Lucia F, Schick U, Reinhold C, Robin P, Hatt M, et al. Comparison of radiomic pre-processing steps in the reproducible prediction of disease free survival across multi-scanners / centers. 2021. 133. Chen L, Li S, Bai Q, Yang J, Jiang S, and Miao Y. Review of image classification algorithms based on convolutional neural networks. Remote Sensing 2021;13:4712. 134. Sarvamangala D and Kulkarni RV. Convolutional neural networks in medical im�age understanding: a survey. Evolutionary intelligence 2022;15:1–22. 136 135. Shiri I, Rahmim A, Ghaffarian P, Geramifar P, Abdollahi H, and Bitarafan-Rajabi A. The impact of image reconstruction settings on 18F-FDG PET radiomic fea�tures: multi-scanner phantom and patient studies. European radiology 2017;27:4498– 509. 136. Pfaehler E, Beukinga RJ, Jong JR de, Slart RH, Slump CH, Dierckx RA, and Boel�laard R. Repeatability of 18F-FDG PET radiomic features: A phantom study to explore sensitivity to image reconstruction settings, noise, and delineation method. Medical physics 2019;46:665–78. 137. Reader AJ and Zaidi H. Advances in PET image reconstruction. PET clinics 2007;2:173– 90. 138. Yan J, Chu-Shern JL, Loi HY, Khor LK, Sinha AK, Quek ST, Tham IW, and Townsend D. Impact of image reconstruction settings on texture features in 18F�FDG PET. Journal of nuclear medicine 2015;56:1667–73. 139. Zwanenburg A, Vallieres M, Abdalah MA, Aerts HJ, Andrearczyk V, Apte A, ` Ashrafinia S, Bakas S, Beukinga RJ, Boellaard R, et al. The image biomarker standardization initiative: standardized quantitative radiomics for high-throughput image-based phenotyping. Radiology 2020;295:328. 140. Mali SA, Ibrahim A, Woodruff HC, Andrearczyk V, Muller H, Primakov S, Salahud- ¨ din Z, Chatterjee A, and Lambin P. Making radiomics more reproducible across scanner and imaging protocol variations: a review of harmonization methods. Jour�nal of Personalized Medicine 2021;11:842. 141. Da-Ano R, Visvikis D, and Hatt M. Harmonization strategies for multicenter ra�diomics investigations. Physics in Medicine & Biology 2020;65:24TR02. 142. Gatys LA, Ecker AS, and Bethge M. Image style transfer using convolutional neu�ral networks. In: Proceedings of the IEEE conference on computer vision and pat�tern recognition. 2016:2414–23. 143. Hognon C, Tixier F, Gallinato O, Colin T, Visvikis D, and Jaouen V. Standardiza�tion of multicentric image datasets with generative adversarial networks. In: IEEE Nuclear Science Symposium and Medical Imaging Conference 2019. 2019. 137 144. Modanwal G, Vellal A, Buda M, and Mazurowski MA. MRI image harmonization using cycle-consistent generative adversarial network. In: Medical Imaging 2020: Computer-Aided Diagnosis. Vol. 11314. SPIE. 2020:259–64. 145. Shah J, Gao F, Li B, Ghisays V, Luo J, Chen Y, Lee W, Zhou Y, Benzinger TL, Reiman EM, et al. Deep residual inception encoder-decoder network for amyloid PET harmonization. Alzheimer’s & Dementia 2022. 146. Da-Ano R, Masson I, Lucia F, Dore M, Robin P, Alfieri J, Rousseau C, Mervoyer ´ A, Reinhold C, Castelli J, et al. Performance comparison of modified ComBat for harmonization of radiomic features for multicenter studies. Scientific Reports 2020;10:1–12. 147. Papadimitroulas P, Brocki L, Chung NC, Marchadour W, Vermet F, Gaubert L, Eleftheriadis V, Plachouris D, Visvikis D, Kagadis GC, et al. Artificial intelligence: Deep learning in oncological radiomics and challenges of interpretability and data harmonization. Physica Medica 2021;83:108–21. 148. Orlhac F, Boughdad S, Philippe C, Stalla-Bourdillon H, Nioche C, Champion L, Soussan M, Frouin F, Frouin V, and Buvat I. A postreconstruction harmoniza�tion method for multicenter radiomic studies in PET. Journal of Nuclear Medicine 2018;59:1321–8. 149. Johnson WE, Li C, and Rabinovic A. Adjusting batch effects in microarray expres�sion data using empirical Bayes methods. Biostatistics 2007;8:118–27. 150. Fortin JP, Cullen N, Sheline YI, Taylor WD, Aselcioglu I, Cook PA, Adams P, Cooper C, Fava M, McGrath PJ, et al. Harmonization of cortical thickness mea�surements across scanners and sites. Neuroimage 2018;167:104–20. 151. Timmeren JE van, Cester D, Tanadini-Lang S, Alkadhi H, and Baessler B. Ra�diomics in medical imaging—“How-to” guide and critical reflection. Insights into Imaging 2020;11:1–16. 138 152. Shafiq-ul-Hassan M, Zhang GG, Latifi K, Ullah G, Hunt DC, Balagurunathan Y, Abdalah MA, Schabath MB, Goldgof DG, Mackin D, et al. Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels. Medical physics 2017;44:1050–62. 153. Leijenaar RT, Nalbantov G, Carvalho S, Van Elmpt WJ, Troost EG, Boellaard R, Aerts HJ, Gillies RJ, and Lambin P. The effect of SUV discretization in quantita�tive FDG-PET Radiomics: the need for standardized methodology in tumor texture analysis. Scientific reports 2015;5:1–10. 154. Gallivanone F, Interlenghi M, D’Ambrosio D, Trifiro G, and Castiglioni I. Pa- ` rameters influencing PET imaging features: a phantom study with irregular and heterogeneous synthetic lesions. Contrast media & molecular imaging 2018;2018. 155. Altazi BA, Zhang GG, Fernandez DC, Montejo ME, Hunt D, Werner J, Biagi�oli MC, and Moros EG. Reproducibility of F18-FDG PET radiomic features for different cervical tumor segmentation methods, gray-level discretization, and re�construction algorithms. Journal of applied clinical medical physics 2017;18:32– 48. 156. Piri R, Edenbrandt L, Larsson M, Enqvist O, Nøddeskou-Fink AH, Gerke O, and Høilund-Carlsen PF. Aortic wall segmentation in 18F-sodium fluoride PET/CT scans: Head-to-head comparison of artificial intelligence-based versus manual seg�mentation. Journal of Nuclear Cardiology 2022;29:2001–10. 157. Reinke A, Tizabi MD, Sudre CH, Eisenmann M, Radsch T, Baumgartner M, Acion ¨ L, Antonelli M, Arbel T, Bakas S, et al. Common limitations of image processing metrics: A picture story. arXiv preprint arXiv:2104.05642 2021. 158. Sedghi Gamechi Z, Bons LR, Giordano M, Bos D, Budde RP, Kofoed KF, Peder�sen JH, Roos-Hesselink JW, and Bruijne M de. Automated 3D segmentation and diameter measurement of the thoracic aorta on non-contrast enhanced CT. Euro�pean radiology 2019;29:4613–23. 159. Rahman H, Rahman S, and Din F. Automatic segmentation of the aorta in cardiac medical images. The Nucleus 2017;54:90–6. 139 160. Florez E, Fatemi A, Claudio PP, and Howard CM. Emergence of radiomics: novel methodology identifying imaging biomarkers of disease in diagnosis, response, and progression. SM journal of clinical and medical imaging 2018;4. 161. Jin Y, Pepe A, Li J, Gsaxner C, Zhao Fh, Kleesiek J, Frangi AF, and Egger J. Ai�based aortic vessel tree segmentation for cardiovascular diseases treatment: status quo. arXiv preprint arXiv:2108.02998 2021. 162. Noothout JM, De Vos BD, Wolterink JM, and Isgum I. Automatic segmentation of ˇ thoracic aorta segments in low-dose chest CT. In: Medical Imaging 2018: Image Processing. Vol. 10574. International Society for Optics and Photonics. 2018:105741S. 163. Ronneberger O, Fischer P, and Brox T. U-net: Convolutional networks for biomed�ical image segmentation. In: International Conference on Medical image comput�ing and computer-assisted intervention. Springer. 2015:234–41. 164. Mohammadi S, Mohammadi M, Dehlaghi V, and Ahmadi A. Automatic segmen�tation, detection, and diagnosis of abdominal aortic aneurysm (AAA) using convo�lutional neural networks and hough circles algorithm. Cardiovascular Engineering and Technology 2019;10:490–9. 165. Jha D, Riegler MA, Johansen D, Halvorsen P, and Johansen HD. Doubleu-net: A deep convolutional neural network for medical image segmentation. In: 2020 IEEE 33rd International symposium on computer-based medical systems (CBMS). IEEE. 2020:558–64. 166. Bonechi S, Andreini P, Mecocci A, Giannelli N, Scarselli F, Neri E, Bianchini M, and Dimitri GM. Segmentation of Aorta 3D CT Images Based on 2D Convolu�tional Neural Networks. Electronics 2021;10:2559. 167. Hahn LD, Baeumler K, and Hsiao A. Artificial intelligence and machine learning in aortic disease. Current Opinion in Cardiology 2021;36:695–703. 168. Xie Y, Padgett J, Biancardi AM, and Reeves AP. Automated aorta segmentation in low-dose chest CT images. International journal of computer assisted radiology and surgery 2014;9:211–9. 140 169. Egger J, Freisleben B, Setser R, Renapuraar R, Biermann C, and O’Donnell T. Aorta segmentation for stent simulation. arXiv preprint arXiv:1103.1773 2011. 170. Subasic M, Loncaric S, and Sorantin E. Region-based deformable model for aortic wall segmentation. In: 3rd International Symposium on Image and Signal Process�ing and Analysis, 2003. ISPA 2003. Proceedings of the. Vol. 2. IEEE. 2003:731– 5. 171. Brooks FJ and Grigsby PW. The effect of small tumor volumes on studies of intra�tumoral heterogeneity of tracer uptake. Journal of Nuclear Medicine 2014;55:37– 42. 172. Hatt M, Vallieres M, Visvikis D, and Zwanenburg A. IBSI: an international com�munity radiomics standardization initiative. 2018. 173. Nioche C, Orlhac F, Boughdad S, Reuze S, Goya-Outi J, Robert C, Pellot-Barakat ´ C, Soussan M, Frouin F, and Buvat I. LIFEx: a freeware for radiomic feature cal�culation in multimodality imaging to accelerate advances in the characterization of tumor heterogeneity. Cancer research 2018;78:4786–9. 174. Korte JC, Cardenas C, Hardcastle N, Kron T, Wang J, Bahig H, Elgohari B, Ger R, Court L, Fuller CD, et al. Radiomics feature stability of open-source software evaluated on apparent diffusion coefficient maps in head and neck cancer. Scien�tific reports 2021;11:1–11. 175. Van Griethuysen JJ, Fedorov A, Parmar C, Hosny A, Aucoin N, Narayan V, Beets�Tan RG, Fillion-Robin JC, Pieper S, and Aerts HJ. Computational radiomics sys�tem to decode the radiographic phenotype. Cancer research 2017;77:e104–e107. 176. Song J, Yin Y, Wang H, Chang Z, Liu Z, and Cui L. A review of original arti�cles published in the emerging field of radiomics. European journal of radiology 2020;127:108991. 177. Pfaehler E, Zhovannik I, Wei L, Boellaard R, Dekker A, Monshouwer R, El Naqa I, Bussink J, Gillies R, Wee L, et al. A systematic review and quality of reporting checklist for repeatability and reproducibility of radiomic features. Physics and imaging in radiation oncology 2021;20:69–75. 141 178. Lorbeer R, Grotz A, Dorr M, V ¨ olzke H, Lieb W, K ¨ uhn JP, and Mensel B. Ref- ¨ erence values of vessel diameters, stenosis prevalence, and arterial variations of the lower limb arteries in a male population sample using contrast-enhanced MR angiography. PLoS One 2018;13:e0197559. 179. Samarzija K, Milosevic P, Jurjevic Z, and Erdeljac E. Grading of carotid artery stenosis with computed tomography angiography: whether to use the narrowest diameter or the cross-sectional area. Insights into Imaging 2018;9:527–34. 180. Olson SL, Wijesinha MA, Panthofer AM, Blackwelder WC, Upchurch GR, Terrin ML, Curci JA, Baxter BT, and Matsumura JS. Evaluating growth patterns of ab�dominal aortic aneurysm diameter with serial computed tomography surveillance. JAMA surgery 2021;156:363–70. 181. Polak JF, Kronmal RA, Tell GS, O’Leary DH, Savage PJ, Gardin JM, Rutan GH, and Borhani NO. Compensatory increase in common carotid artery diameter: re�lation to blood pressure and artery intima-media thickness in older adults. Stroke 1996;27:2012–5. 182. Thapar A, Cheal D, Hopkins T, Ward S, Shaloub J, and Yusuf S. Internal or external wall diameter for abdominal aortic aneurysm screening? The Annals of The Royal College of Surgeons of England 2010;92:503–5. 183. Olive DJ. Principal component analysis. In: Robust multivariate analysis. Springer, 2017:189–217. 184. Fawcett T. An introduction to ROC analysis. Pattern recognition letters 2006;27:861– 74. 185. Leevy JL, Khoshgoftaar TM, Bauder RA, and Seliya N. A survey on addressing high-class imbalance in big data. Journal of Big Data 2018;5:1–30. 186. Klawonn F, Hoppner F, and May S. An alternative to ROC and AUC analysis of ¨ classifiers. In: Advances in Intelligent Data Analysis X: 10th International Sympo�sium, IDA 2011, Porto, Portugal, October 29-31, 2011. Proceedings 10. Springer. 2011:210–21. 142 187. Provost F and Fawcett T. Robust classification for imprecise environments. Ma�chine learning 2001;42:203–31. 188. Ling CX, Huang J, Zhang H, et al. AUC: a statistically consistent and more dis�criminating measure than accuracy. In: Ijcai. Vol. 3. 2003:519–24. 189. Halligan S, Altman DG, and Mallett S. Disadvantages of using the area under the receiver operating characteristic curve to assess imaging tests: a discussion and proposal for an alternative approach. European radiology 2015;25:932–9. 190. Harrington MB. Some methodological questions concerning receiver operating characteristic (ROC) analysis as a method for assessing image quality in radiol�ogy. Journal of digital imaging 1990;3:211–8. 191. Chalkidou A, O’Doherty MJ, and Marsden PK. False discovery rates in PET and CT studies with texture features: a systematic review. PloS one 2015;10:e0124165. 192. O’Connor JP, Aboagye EO, Adams JE, Aerts HJ, Barrington SF, Beer AJ, Boel�laard R, Bohndiek SE, Brady M, Brown G, et al. Imaging biomarker roadmap for cancer studies. Nature reviews Clinical oncology 2017;14:169–86. 193. Vallieres M, Zwanenburg A, Badic B, Le Rest CC, Visvikis D, and Hatt M. Re- ` sponsible radiomics research for faster clinical translation. 2018. 194. Collins GS, Reitsma JB, Altman DG, and Moons KG. Transparent reporting of a multivariable prediction model for individual prognosis or diagnosis (TRIPOD): the TRIPOD statement. Journal of British Surgery 2015;102:148–58. 195. Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig L, Lijmer JG, Moher D, Rennie D, De Vet HC, et al. STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. Clinical chemistry 2015;61:1446– 52. 196. Chen C, Grennan K, Badner J, Zhang D, Gershon E, Jin L, and Liu C. Removing batch effects in analysis of expression microarray data: an evaluation of six batch adjustment methods. PloS one 2011;6:e17238. 143 197. Jochems A, Deist TM, Van Soest J, Eble M, Bulens P, Coucke P, Dries W, Lambin P, and Dekker A. Distributed learning: developing a predictive model based on data from multiple hospitals without data leaving the hospital–a real life proof of concept. Radiotherapy and Oncology 2016;121:459–67. 198. Zerka F, Barakat S, Walsh S, Bogowicz M, Leijenaar RT, Jochems A, Miraglio B, Townend D, and Lambin P. Systematic review of privacy-preserving distributed machine learning from federated databases in health care. JCO clinical cancer in�formatics 2020;4:184–200. 199. Michael JR, Stanley C, Adamson R, and Kotevska O. Addressing the Limitations to Distributed Learning Containing Sensitive Data. 200. Verbraeken J, Wolting M, Katzy J, Kloppenburg J, Verbelen T, and Rellermeyer JS. A survey on distributed machine learning. Acm computing surveys (csur) 2020;53:1– 33. 201. Ford RA, Price W, and Nicholson I. Privacy and accountability in black-box medicine. Mich. Telecomm. & Tech. L. Rev. 2016;23:1. 202. Wang S, Dong D, Li L, Li H, Bai Y, Hu Y, Huang Y, Yu X, Liu S, Qiu X, et al. A deep learning radiomics model to identify poor outcome in COVID-19 patients with underlying health conditions: A multicenter study. IEEE Journal of Biomedi�cal and Health Informatics 2021;25:2353–62. 203. Wennmann M, Klein A, Bauer F, Chmelik J, Grozinger M, Uhlenbrock C, Lochner ¨ J, Nonnenmacher T, Rotkopf LT, Sauer S, et al. Combining deep learning and radiomics for automated, objective, comprehensive bone marrow characterization from whole-body MRI: a multicentric feasibility study. Investigative Radiology 2022;57:752–63. 204. Brown P, Zhong J, Frood R, Currie S, Gilbert A, Appelt A, Sebag-Montefiore D, and Scarsbrook A. Prediction of outcome in anal squamous cell carcinoma using radiomic feature analysis of pre-treatment FDG PET-CT. European journal of nu�clear medicine and molecular imaging 2019;46:2790–9. 144 205. Boellaard R, Delgado-Bolton R, Oyen WJ, Giammarile F, Tatsch K, Eschner W, Verzijlbergen FJ, Barrington SF, Pike LC, Weber WA, et al. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0. European journal of nuclear medicine and molecular imaging 2015;42:328–54. 206. Kikinis R, Pieper SD, and Vosburgh KG. 3D Slicer: a platform for subject-specific image analysis, visualization, and clinical support. In: Intraoperative imaging and image-guided therapy. Springer, 2014:277–89. 207. Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M, et al. 3D Slicer as an image comput�ing platform for the Quantitative Imaging Network. Magnetic resonance imaging 2012;30:1323–41. 208. Steyerberg EW. Validation in prediction research: the waste by data splitting. Jour�nal of clinical epidemiology 2018;103:131–3. 209. Langs G, Rohrich S, Hofmanninger J, Prayer F, Pan J, Herold C, and Prosch ¨ H. Machine learning: from radiomics to discovery and routine. Der Radiologe 2018;58:1–6. 210. Nappi C and Cuocolo A. The machine learning approach: Artificial intelligence is coming to support critical clinical thinking. 2020. 211. Shrestha S and Sengupta PP. Machine learning for nuclear cardiology: The way forward. 2019. 212. Lodge MA, Chaudhry MA, and Wahl RL. Noise considerations for PET quantifi�cation using maximum and peak standardized uptake value. Journal of Nuclear Medicine 2012;53:1041–7. 213. Duff L, Scarsbrook AF, Mackie SL, Frood R, Bailey M, Morgan AW, and Tsoumpas C. A methodological framework for AI-assisted diagnosis of active aortitis using Radiomic analysis of FDG PET–CT Images: Initial analysis. Journal of Nuclear Cardiology 2022. 214. Hatt M, Lucia F, Schick U, and Visvikis D. Multicentric validation of radiomics findings: challenges and opportunities. EBioMedicine 2019;47:20–1. 145 215. Duff LM, Scarsbrook AF, Ravikumar N, Frood R, Praagh GD van, Mackie SL, Bailey MA, Tarkin JM, Mason JC, Geest KS van der, et al. An Automated Method for Artifical Intelligence Assisted Diagnosis of Active Aortitis Using Radiomic Analysis of FDG PET-CT Images. Biomolecules 2023;13:343. 216. LIDA. Target. Last accessed 1st April 2022. 2022. URL: https://lida.leeds. ac.uk/target/. 217. Dice LR. Measures of the amount of ecologic association between species. Ecol�ogy 1945;26:297–302. 218. Van Griethuysen JJ, Fedorov A, Parmar C, Hosny A, Aucoin N, Narayan V, Beets�Tan RG, Fillion-Robin JC, Pieper S, and Aerts HJ. Computational radiomics sys�tem to decode the radiographic phenotype. Cancer research 2017;77:e104–e107. 219. Xing H, Hao Z, Zhu W, Sun D, Ding J, Zhang H, Liu Y, and Huo L. Preoper�ative prediction of pathological grade in pancreatic ductal adenocarcinoma based on 18F-FDG PET/CT radiomics. EJNMMI research 2021;11:1–10. 220. Sun X and Xu W. Fast implementation of DeLong’s algorithm for comparing the areas under correlated receiver operating characteristic curves. IEEE Signal Pro�cessing Letters 2014;21:1389–93. 221. DeLong ER, DeLong DM, and Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988:837–45. 222. Larue RT, Defraene G, De Ruysscher D, Lambin P, and Van Elmpt W. Quantitative radiomics studies for tissue characterization: a review of technology and method�ological procedures. The British journal of radiology 2017;90:20160665. 223. Lopez-Linares K, Garcıa I, Garcıa-Familiar A, Macıa I, and Ballester MAG. 3D ´ convolutional neural network for abdominal aortic aneurysm segmentation. arXiv preprint arXiv:1903.00879 2019. 224. Sollini M, Antunovic L, Chiti A, and Kirienko M. Towards clinical application of image mining: a systematic review on artificial intelligence and radiomics. Euro�pean journal of nuclear medicine and molecular imaging 2019:1–17. 146 225. Ronrick Da, Lucia F, Masson I, Abgral R, Alfieri J, Rousseau C, Mervoyer A, Reinhold C, Pradier O, Schick U, et al. Pre-selecting radiomic features based on their robustness to changes in imaging properties of multicentre data: impact on predictive modelling performance compared to ComBat harmonization of all avail�able features. 2021. 226. Schlett C, Hendel T, Weckbach S, Reiser M, Kauczor H, Nikolaou K, Gunther M, ¨ Forsting M, Hosten N, Volzke H, et al. Population-based imaging and radiomics: ¨ rationale and perspective of the German National Cohort MRI Study. In: RoFo- ¨ Fortschritte auf dem Gebiet der Rontgenstrahlen und der bildgebenden Verfahren ¨ . Vol. 188. 07. © Georg Thieme Verlag KG. 2016:652–61. 227. Traverso A, Wee L, Dekker A, and Gillies R. Repeatability and reproducibility of radiomic features: a systematic review. International Journal of Radiation Oncol�ogy* Biology* Physics 2018;102:1143–58. 228. Fei JL, Pu CL, Xu FY, Wu Y, and Hu HJ. Progress in radiomics of common heart disease based on cardiac magnetic resonance imaging. Journal of Molecular and Clinical Medicine 2021;4:29–38. 229. Juarez-Orozco LE, Martinez-Manzanera O, Zant FM van der, Knol RJ, and Knuuti J. Deep learning in quantitative PET myocardial perfusion imaging: a study on cardiovascular event prediction. Cardiovascular Imaging 2020;13:180–2. 230. Kwiecinski J, Kolossvary M, Tzolos E, Meah M, Adamson P, Joshi N, Williams M, Van Beek E, Berman D, Maurovich-Horvat P, et al. 18F-sodium fluoride positron emission tomography and coronary plaque radiomics derived from computed to�mography angiography for prediction of myocardial infarction. European Heart Journal 2022;43:ehac544–212. 231. Yip SS and Aerts HJ. Applications and limitations of radiomics. Physics in Medicine & Biology 2016;61:R150. 232. Ibrahim A, Primakov S, Barufaldi B, Acciavatti RJ, Granzier RW, Hustinx R, Mot�taghy FM, Woodruff HC, Wildberger JE, Lambin P, et al. The effects of in-plane 147 spatial resolution on CT-based radiomic features’ stability with and without Com�Bat harmonization. Cancers 2021;13:1848. 233. Orlhac F and Buvat I. Comment on Ibrahim et al. The Effects of In-Plane Spatial Resolution on CT-Based Radiomic Features’ Stability with and without ComBat Harmonization. Cancers 2021, 13, 1848. Cancers 2021;13:3037. 234. Orlhac F, Eertink JJ, Cottereau AS, Zijlstra JM, Thieblemont C, Meignan MA, Boellaard R, and Buvat I. A guide to ComBat harmonization of imaging biomark�ers in multicenter studies. Journal of Nuclear Medicine 2021. 235. Bettinelli A, Marturano F, Avanzo M, Loi E, Menghi E, Mezzenga E, Pirrone G, Sarnelli A, Strigari L, Strolin S, and Paiusco M. A Novel Benchmarking Ap�proach to Assess the Agreement among Radiomic Tools. Radiology 0000;0. PMID: 35230182:211604. 236. Carles M, Fechter T, Martı-Bonmatı L, Baltas D, and Mix M. Experimental phan�tom evaluation to identify robust positron emission tomography (PET) radiomic features. EJNMMI physics 2021;8:1–17. 237. Oliveira C, Amstutz F, Vuong D, Bogowicz M, Hullner M, Foerster R, Basler L, ¨ Schroder C, Eboulet EI, Pless M, et al. Preselection of robust radiomic features ¨ does not improve outcome modelling in non-small cell lung cancer based on clini�cal routine FDG-PET imaging. EJNMMI research 2021;11:1–12. 238. Toner YC, Ghotbi AA, Naidu S, Sakurai K, Leent MM van, Jordan S, Ordikhani F, Amadori L, Sofias AM, Fisher EL, et al. Systematically evaluating DOTATATE and FDG as PET immuno-imaging tracers of cardiovascular inflammation. Scientific reports 2022;12:1–15. 239. Jensen JK, Madsen JS, Jensen ME, Kjaer A, and Ripa RS. [64Cu] Cu-DOTATATE PET metrics in the investigation of atherosclerotic inflammation in humans. Jour�nal of Nuclear Cardiology 2022:1–15. 148 240. Jiemy WF, Heeringa P, Kamps JA, Laken CJ van der, Slart RH, and Brouwer E. Positron emission tomography (PET) and single photon emission computed to�mography (SPECT) imaging of macrophages in large vessel vasculitis: current sta�tus and future prospects. Autoimmunity reviews 2018;17:715–26. 241. Pugliese F, Gaemperli O, Kinderlerer AR, Lamare F, Shalhoub J, Davies AH, Rimoldi OE, Mason JC, and Camici PG. Imaging of vascular inflammation with [11C]-PK11195 and positron emission tomography/computed tomography angiog�raphy. Journal of the American College of Cardiology 2010;56:653–61. 242. Lamare F, Hinz R, Gaemperli O, Pugliese F, Mason JC, Spinks T, Camici PG, and Rimoldi OE. Detection and quantification of large-vessel inflammation with 11C-(R)-PK11195 PET/CT. Journal of Nuclear Medicine 2011;52:33–9. 243. Espitia O, Schanus J, Agard C, Kraeber-Boder´ e F, Hersant J, Serfaty JM, and Jamet ´ B. Specific features to differentiate Giant cell arteritis aortitis from aortic atheroma using FDG-PET/CT. Scientific Reports 2021;11:1–10. 244. Zerizer I, Tan K, Khan S, Barwick T, Marzola MC, Rubello D, and Al-Nahhas A. Role of FDG-PET and PET/CT in the diagnosis and management of vasculitis. European journal of radiology 2010;73:504–9. 245. Soussan M, Nicolas P, Schramm C, Katsahian S, Pop G, Fain O, and Mekinian A. Management of large-vessel vasculitis with FDG-PET: a systematic literature review and meta-analysis. Medicine 2015;94. 246. Tatsumi M, Cohade C, Nakamoto Y, and Wahl RL. Fluorodeoxyglucose uptake in the aortic wall at PET/CT: possible finding for active atherosclerosis. Radiology 2003;229:831–7. 247. Tomaszewski MR and Gillies RJ. The biological meaning of radiomic features. Radiology 2021;298:505–16"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Integrated Ph.D and Master"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.878045"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/L014823/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/32404/1/Thesis%20%288%29.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Aortitis refers to inflammatory conditions affecting the aortic wall that cannot be explained by atherosclerosis alone. Large Vessel Vasculitis (LVV) is the main type of non-infectious aortitis and can affect any of the large arteries. Aortitis and LVV are difficult to diagnose and treat due to a variety of reasons such as non-specific symptoms and diagnostic tests, a large number of potential causes, and risks involved in providing incorrect or delayed treatment. [18F]-Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET-CT) imaging plays a key role in diagnosis of LVV due to its ability to detect inflammation early and non-invasively, but is mostly assessed qualitatively making its interpretation vulnerable to bias and inter-observer variation. Therefore, there is a need for more reliable imaging biomarkers which can be achieved with radiomic analysis. The aim of this thesis is to explore the diagnostic ability of radiomic features in FDG PET-CT imaging of aortitis. First, the feasibility is determined and a methodological pipeline established. Next, the findings are validated with data from multiple centres and the overall method automated. The first step of the method is the aortic segmentation using an artificial intelligence which produces similar radiomic features as the manual segmentation. When used as input in the diagnostic models, several individual radiomic features and groups of radiomic features demonstrated high diagnostic performance across the training, test and validation cohorts. In particular features based on heterogeneity perform well. The method displayed good generalizability and transferability which is important prerequisites for clinical use. These findings could be used to build an automated clinical decision tool which would facilitate objective and standardized assessment regardless of observer experience."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Intelligent feature analysis of FDG PET-CT images for more accurate diagnosis in large vessel vasculitis"]}]}],"canonical_facts":{"dc:contributor.advisor":["Scarsbrook, Andrew F","Mackie, Sarah L","Bailey, Marc A","Morgan, Ann W","Tsoumpas, Charalampos"],"dc:contributor.sponsor":["EPSRC"],"dc:creator":["Duff, Lisa Mairi"],"dc:date":["2022-11"],"dc:date.issued":["2022-11"],"dc:description.abstract":["Aortitis refers to inflammatory conditions affecting the aortic wall that cannot be explained by atherosclerosis alone. Large Vessel Vasculitis (LVV) is the main type of non-infectious aortitis and can affect any of the large arteries. Aortitis and LVV are difficult to diagnose and treat due to a variety of reasons such as non-specific symptoms and diagnostic tests, a large number of potential causes, and risks involved in providing incorrect or delayed treatment. [18F]-Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography (FDG PET-CT) imaging plays a key role in diagnosis of LVV due to its ability to detect inflammation early and non-invasively, but is mostly assessed qualitatively making its interpretation vulnerable to bias and inter-observer variation. Therefore, there is a need for more reliable imaging biomarkers which can be achieved with radiomic analysis. The aim of this thesis is to explore the diagnostic ability of radiomic features in FDG PET-CT imaging of aortitis. First, the feasibility is determined and a methodological pipeline established. Next, the findings are validated with data from multiple centres and the overall method automated. The first step of the method is the aortic segmentation using an artificial intelligence which produces similar radiomic features as the manual segmentation. When used as input in the diagnostic models, several individual radiomic features and groups of radiomic features demonstrated high diagnostic performance across the training, test and validation cohorts. In particular features based on heterogeneity perform well. The method displayed good generalizability and transferability which is important prerequisites for clinical use. These findings could be used to build an automated clinical decision tool which would facilitate objective and standardized assessment regardless of observer experience."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.878045"],"dc:identifier.grantnumber":["EP/L014823/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/32404/1/Thesis%20%288%29.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Mechanical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/32404/"],"dc:relation.references":["1. . Pugh D, Grayson P, Basu N, and Dhaun N. Aortitis: recent advances, current con�cepts and future possibilities. Heart 2021;107:1620–9. 2. Parikh M, Miller NR, Lee AG, Savino PJ, Vacarezza MN, Cornblath W, Eggen�berger E, Antonio-Santos A, Golnik K, Kardon R, et al. Prevalence of a normal C�reactive protein with an elevated erythrocyte sedimentation rate in biopsy-proven giant cell arteritis. Ophthalmology 2006;113:1842–5. 3. Monach PA. Biomarkers in vasculitis. Current opinion in rheumatology 2014;26:24. 4. Gornik HL and Creager MA. Aortitis. Circulation 2008;117:3039–51. 5. Stone JR, Bruneval P, Angelini A, Bartoloni G, Basso C, Batoroeva L, Buja LM, Butany J, d’Amati G, Fallon JT, et al. Consensus statement on surgical pathology of the aorta from the Society for Cardiovascular Pathology and the Association for European Cardiovascular Pathology: I. Inflammatory diseases. Cardiovascular Pathology 2015;24:267–78. 6. Marvisi C, Buttini EA, and Vaglio A. Aortitis and periaortitis: the puzzling spec�trum of inflammatory aortic diseases. La Presse Medicale 2020;49:104018. ´ 7. Monti S, Agueda AF, Luqmani RA, Buttgereit F, Cid M, Dejaco C, Mahr A, Ponte ´ C, Salvarani C, Schmidt W, et al. Systematic literature review informing the 2018 update of the EULAR recommendation for the management of large vessel vas�culitis: focus on giant cell arteritis. RMD open 2019;5:e001003. 121 122 8. Wallace ZS, Zhang Y, Perugino CA, Naden R, Choi HK, and Stone JH. Clin�ical phenotypes of IgG4-related disease: an analysis of two international cross�sectional cohorts. Annals of the rheumatic diseases 2019;78:406–12. 9. Peng L, Zhang P, Li J, Liu Z, Lu H, Zhu L, Wang X, Teng F, Li X, Guo H, et al. IgG4-related aortitis/periaortitis and periarteritis: a distinct spectrum of IgG4- related disease. Arthritis Research & Therapy 2020;22:1–11. 10. Horton B. An undescribed form of arteritis of temporal vessels. Proc Staff Mayo Clin Proc 1932;7:700–1. 11. Muratore F, Kermani TA, Crowson CS, Green AB, Salvarani C, Matteson EL, and Warrington KJ. Large-vessel giant cell arteritis: a cohort study. Rheumatology 2015;54:463–70. 12. Koster MJ, Matteson EL, and Warrington KJ. Large-vessel giant cell arteritis: di�agnosis, monitoring and management. Rheumatology 2018;57:ii32–ii42. 13. Kebed DT, Bois JP, Connolly HM, Scott CG, Bowen JM, Warrington KJ, Makol A, Greason KL, Schaff HV, and Anavekar NS. Spectrum of aortic disease in the giant cell arteritis population. The American Journal of Cardiology 2018;121:501– 8. 14. Dejaco C, Ramiro S, Duftner C, Besson FL, Bley TA, Blockmans D, Brouwer E, Cimmino MA, Clark E, Dasgupta B, et al. EULAR recommendations for the use of imaging in large vessel vasculitis in clinical practice. Annals of the rheumatic diseases 2018;77:636–43. 15. Salvarani C, Cantini F, and Hunder GG. Polymyalgia rheumatica and giant-cell arteritis. The Lancet 2008;372:234–45. 16. Maksimowicz-McKinnon K, Clark TM, and Hoffman GS. Takayasu arteritis and giant cell arteritis: a spectrum within the same disease? Medicine 2009;88:221–6. 17. Gonzalez-Gay MA, Garcıa-Porr ´ ua C, Llorca J, Hajeer AH, Bra ´ nas F, Dababneh ˜ A, Gonzalez-Louzao C, Rodriguez-Gil E, Rodrıguez-Ledo P, and Ollier W. Visual ´ manifestations of giant cell arteritis. Trends and clinical spectrum in 161 patients. Medicine 2000;79:283–92. 123 18. Gonzalez-Gay MA, Barros S, Lopez-Diaz MJ, Garcia-Porrua C, Sanchez-Andrade A, and Llorca J. Giant cell arteritis: disease patterns of clinical presentation in a series of 240 patients. Medicine 2005;84:269–76. 19. Robson JC, Kiran A, Maskell J, Hutchings A, Arden N, Dasgupta B, Hamilton W, Emin A, Culliford D, and Luqmani RA. The relative risk of aortic aneurysm in patients with giant cell arteritis compared with the general population of the UK. Annals of the rheumatic diseases 2015;74:129–35. 20. Richards BL, March L, and Gabriel SE. Epidemiology of large-vessel vasculidities. Best Practice & Research Clinical Rheumatology 2010;24:871–83. 21. Zaldivar Villon ML, Rocha JAL de la, and Espinoza LR. Takayasu arteritis: recent developments. Current Rheumatology Reports 2019;21:1–10. 22. Goel R, Chandan JS, Thayakaran R, Adderley NJ, Nirantharakumar K, and Harper L. Cardiovascular and renal morbidity in Takayasu arteritis: a Population-Based retrospective cohort study from the United Kingdom. Arthritis & Rheumatology 2021;73:504–11. 23. Petri H, Nevitt A, Sarsour K, Napalkov P, and Collinson N. Incidence of giant cell arteritis and characteristics of patients: data-driven analysis of comorbidities. Arthritis care & research 2015;67:390–5. 24. Sharma A, Mohammad AJ, and Turesson C. Incidence and prevalence of giant cell arteritis and polymyalgia rheumatica: a systematic literature review. In: Seminars in Arthritis and Rheumatism. Vol. 50. 5. Elsevier. 2020:1040–8. 25. Watts R, Al-Taiar A, Mooney J, Scott D, and MacGregor A. The epidemiology of Takayasu arteritis in the UK. Rheumatology 2009;48:1008–11. 26. Clifford AH, Arafat A, Idrees JJ, Roselli EE, Tan CD, Rodriguez ER, Svensson LG, Blackstone E, Johnston D, Pettersson G, et al. Outcomes among 196 patients with noninfectious proximal aortitis. Arthritis & Rheumatology 2019;71:2112–20. 27. Ferfar Y, Morinet S, Espitia O, Agard C, Vautier M, Comarmond C, Desbois AC, Domont F, Fouret PJ, Redheuil A, et al. Long-Term outcome and prognosis factors of isolated aortitis. Circulation 2020;142:92–4. 124 28. Tomasson G, Peloquin C, Mohammad A, Love TJ, Zhang Y, Choi HK, and Merkel PA. Risk for cardiovascular disease early and late after a diagnosis of giant-cell arteritis: a cohort study. Annals of internal medicine 2014;160:73–80. 29. Koster MJ, Warrington KJ, and Matteson EL. Morbidity and mortality of large�vessel vasculitides. Current rheumatology reports 2020;22:1–13. 30. Buttgereit F, Matteson EL, Dejaco C, and Dasgupta B. Prevention of glucocorti�coid morbidity in giant cell arteritis. Rheumatology 2018;57:ii11–ii21. 31. Foote EA, Postier RG, Greenfield RA, and Bronze MS. Infectious aortitis. Current Treatment Options in Cardiovascular Medicine 2005;7:89–97. 32. Barra L, Pope JE, Pequeno P, Gatley JM, and Widdifield J. Increased mortality for individuals with Giant Cell Arteritis: a population-based study. Arthritis Care & Research 2021. 33. Therkildsen P, Nielsen BD, Thurah A de, Hansen IT, Nørgaard M, and Hauge EM. All-cause and cause-specific mortality in patients with giant cell arteritis: a nationwide, population-based cohort study. Rheumatology 2022;61:1195–203. 34. Hill CL, Black RJ, Nossent JC, Ruediger C, Nguyen L, Ninan JV, and Lester S. Risk of mortality in patients with giant cell arteritis: a systematic review and meta�analysis. In: Seminars in arthritis and rheumatism. Vol. 46. 4. Elsevier. 2017:513– 9. 35. Uddhammar A, Eriksson AL, Nystrom L, Stenling R, and Rantap ¨ a¨a-Dahlqvist S. ¨ Increased mortality due to cardiovascular disease in patients with giant cell arteritis in northern Sweden. The Journal of Rheumatology 2002;29:737–42. 36. Muratore F, Pipitone N, and Salvarani C. Standard and biological treatment in large vessel vasculitis: guidelines and current approaches. Expert review of clinical immunology 2017;13:345–60. 37. Hellmich B, Agueda A, Monti S, Buttgereit F, De Boysson H, Brouwer E, Cassie R, Cid MC, Dasgupta B, Dejaco C, et al. 2018 Update of the EULAR recom�mendations for the management of large vessel vasculitis. Annals of the rheumatic diseases 2020;79:19–30. 125 38. Wilson JC, Sarsour K, Collinson N, Tuckwell K, Musselman D, Klearman M, Na�palkov P, Jick SS, Stone JH, and Meier CR. Serious adverse effects associated with glucocorticoid therapy in patients with giant cell arteritis (GCA): a nested case–control analysis. In: Seminars in arthritis and rheumatism. Vol. 46. 6. Else�vier. 2017:819–27. 39. Wu J, Keeley A, Mallen C, Morgan AW, and Pujades-Rodriguez M. Incidence of infections associated with oral glucocorticoid dose in people diagnosed with polymyalgia rheumatica or giant cell arteritis: a cohort study in England. Cmaj 2019;191:E680–E688. 40. Wu J, Mackie SL, and Pujades-Rodriguez M. Glucocorticoid dose-dependent risk of type 2 diabetes in six immune-mediated inflammatory diseases: a population�based cohort analysis. BMJ Open Diabetes Research and Care 2020;8:e001220. 41. Pujades-Rodriguez M, Morgan AW, Cubbon RM, and Wu J. Dose-dependent oral glucocorticoid cardiovascular risks in people with immune-mediated inflammatory diseases: A population-based cohort study. PLoS medicine 2020;17:e1003432. 42. Stone JH, Tuckwell K, Dimonaco S, Klearman M, Aringer M, Blockmans D, Brouwer E, Cid MC, Dasgupta B, Rech J, et al. Trial of tocilizumab in giant-cell arteritis. New England Journal of Medicine 2017;377:317–28. 43. Chang HW, Kim SH, Hakim AR, Chung S, Kim DJ, Lee JH, Kim JS, Lim C, and Park KH. Diameter and growth rate of the thoracic aorta—analysis based on serial computed tomography scans. Journal of Thoracic Disease 2020;12:4002. 44. Mensel B, Quadrat A, Schneider T, Kuhn JP, D ¨ orr M, V ¨ olzke H, Lieb W, Hegen- ¨ scheid K, and Lorbeer R. MRI-based determination of reference values of thoracic aortic wall thickness in a general population. European radiology 2014;24:2038– 44. 45. Choe YH, Han BK, Koh EM, Kim DK, Do YS, and Lee WR. Takayasu’s arteri�tis: assessment of disease activity with contrast-enhanced MR imaging. American Journal of Roentgenology 2000;175:505–11. 126 46. Tso E, Flamm SD, White RD, Schvartzman PR, Mascha E, and Hoffman GS. Takayasu arteritis: utility and limitations of magnetic resonance imaging in di�agnosis and treatment. Arthritis & Rheumatism: Official Journal of the American College of Rheumatology 2002;46:1634–42. 47. Besutti G, Muratore F, Mancuso P, Ferrari M, Galli E, Spaggiari L, Monelli F, Casali M, Versari A, Boiardi L, et al. Vessel inflammation and morphological changes in patients with large vessel vasculitis: a retrospective study. RMD open 2022;8:e001977. 48. Muto G, Yamashita H, Takahashi Y, Miyata Y, Morooka M, Minamimoto R, Kubota K, Kaneko H, Kano T, and Mimori A. Large vessel vasculitis in elderly patients: early diagnosis and steroid-response evaluation with FDG-PET/CT and contrast-enhanced CT. Rheumatology international 2014;34:1545–54. 49. Quinn KA, Ahlman MA, Alessi HD, LaValley MP, Neogi T, Marko J, Novakovich E, and Grayson PC. Association of 18F-Fluorodeoxyglucose Positron Emission Tomography and Angiographic Progression of Disease in Large-Vessel Vasculitis. Arthritis & Rheumatology 2022. 50. Nienhuis PH, Praagh GD van, Glaudemans AW, Brouwer E, and Slart RH. A re�view on the value of imaging in differentiating between large vessel vasculitis and atherosclerosis. Journal of personalized medicine 2021;11:236. 51. Planas-Rigol E, Corbera-Bellalta M, Espıgol-Frigole G, Terrades-Garcia N, Alba ´ M, et al. Giant-Cell Arteritis: Immunopathogenic Mechanisms Involved in Vascu�lar Inflammation and Remodeling. J Vasc 1: 103. doi: 10.4172/2471-9544.100103 Page 2 of 7 J Vasc ISSN: 2471-9544 JOV, an open access journal Volume 1• Issue 2• 100103. dose glucocorticoids, neutrophils have lower membrane expression of integrin CD11b, are less adhesive to endothelial cells and are able to suppress T cell proliferation. These abnormalities revert when 2016:3. 52. Gajree S, Borooah S, Dhillon N, Goudie C, Smith C, Aspinall P, and Dhillon B. Temporal artery biopsies in south-east Scotland: a five year review. The Journal of the Royal College of Physicians of Edinburgh 2017;47:124–8. 127 53. Slart RH et al. FDG-PET/CT (A) imaging in large vessel vasculitis and polymyal�gia rheumatica: joint procedural recommendation of the EANM, SNMMI, and the PET Interest Group (PIG), and endorsed by the ASNC. European journal of nuclear medicine and molecular imaging 2018;45:1250–69. 54. Slart RH, Glaudemans AW, Gheysens O, Lubberink M, Kero T, Dweck MR, Habib G, Gaemperli O, Saraste A, Gimelli A, et al. Procedural recommendations of car�diac PET/CT imaging: standardization in inflammatory-, infective-, infiltrative-, and innervation (4Is)-related cardiovascular diseases: a joint collaboration of the EACVI and the EANM. European Journal of Nuclear Medicine and Molecular Imaging 2020:1–24. 55. Ehman EC, Johnson GB, Villanueva-Meyer JE, Cha S, Leynes AP, Larson PEZ, and Hope TA. PET/MRI: where might it replace PET/CT? Journal of Magnetic Resonance Imaging 2017;46:1247–62. 56. Basu S, Kwee TC, Surti S, Akin EA, Yoo D, and Alavi A. Fundamentals of PET and PET/CT imaging. Annals of the New York Academy of Sciences 2011;1228:1– 18. 57. Levin CS and Hoffman EJ. Calculation of positron range and its effect on the fun�damental limit of positron emission tomography system spatial resolution. Physics in Medicine & Biology 1999;44:781. 58. Conti M and Eriksson L. Physics of pure and non-pure positron emitters for PET: a review and a discussion. EJNMMI physics 2016;3:1–17. 59. Schmitz RE, Alessio AM, Kinahan PE, Mason NS, and Lin EC. The physics of PET/Ct scanners. PET and PET/CT: a clinical guide 2005;3. 60. Berger A. How does it work?: Positron emission tomography. BMJ: British Medi�cal Journal 2003;326:1449. 61. Humm JL, Rosenfeld A, and Del Guerra A. From PET detectors to PET scanners. European journal of nuclear medicine and molecular imaging 2003;30:1574–97. 128 62. Moses WW. Fundamental limits of spatial resolution in PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detec�tors and Associated Equipment 2011;648:S236–S240. 63. Rapisarda E, Bettinardi V, Thielemans K, and Gilardi M. Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET. Physics in medicine & biology 2010;55:4131. 64. Slomka PJ, Pan T, Berman DS, and Germano G. Advances in SPECT and PET hardware. Progress in Cardiovascular Diseases 2015;57:566–78. 65. Surti S and Karp JS. Update on latest advances in time-of-flight PET. Physica Medica 2020;80:251–8. 66. Slomka PJ, Pan T, and Germano G. Recent advances and future progress in PET instrumentation. In: Seminars in nuclear medicine. Vol. 46. 1. Elsevier. 2016:5–19. 67. Bailey DL and Meikle SR. A convolution-subtraction scatter correction method for 3D PET. Physics in Medicine & Biology 1994;39:411. 68. Levin CS, Dahlbom M, and Hoffman EJ. A Monte Carlo correction for the effect of Compton scattering in 3-D PET brain imaging. IEEE transactions on nuclear science 1995;42:1181–5. 69. Watson CC, Newport D, and Casey ME. A single scatter simulation technique for scatter correction in 3D PET. Three-dimensional image reconstruction in radiology and nuclear medicine 1996:255–68. 70. Ollinger JM. Model-based scatter correction for fully 3D PET. Physics in Medicine & Biology 1996;41:153. 71. Polycarpou I, Thielemans K, Manjeshwar R, Aguiar P, Marsden PK, and Tsoumpas C. Comparative evaluation of scatter correction in 3D PET using different scatter�level approximations. Annals of nuclear medicine 2011;25:643–9. 72. Brasse D, Kinahan PE, Lartizien C, Comtat C, Casey M, and Michel C. Correction methods for random coincidences in fully 3D whole-body PET: impact on data and image quality. Journal of nuclear medicine 2005;46:859–67. 129 73. Słomski A, Rudy Z, Bednarski T, Białas P, Czerwinski E, Kapłon Ł, Kochanowski ´ A, Korcyl G, Kowal J, Kowalski P, et al. 3D PET image reconstruction based on the maximum likelihood estimation method (MLEM) algorithm. Bio-Algorithms and Med-Systems 2014;10:1–7. 74. Shepp LA and Vardi Y. Maximum likelihood reconstruction for emission tomog�raphy. IEEE transactions on medical imaging 1982;1:113–22. 75. Miller TR and Wallis JW. Clinically important characteristics of maximum-likelihood reconstruction. Journal of Nuclear Medicine 1992;33:1678–84. 76. Boellaard R, Van Lingen A, and Lammertsma AA. Experimental and clinical eval�uation of iterative reconstruction (OSEM) in dynamic PET: quantitative character�istics and effects on kinetic modeling. Journal of Nuclear Medicine 2001;42:808– 17. 77. Hudson HM and Larkin RS. Accelerated image reconstruction using ordered sub�sets of projection data. IEEE transactions on medical imaging 1994;13:601–9. 78. Bettinardi V, Presotto L, Rapisarda E, Picchio M, Gianolli L, and Gilardi M. Physical Performance of the new hybrid PET/CT Discovery-690. Medical physics 2011;38:5394–411. 79. Aide N, Lasnon C, Kesner A, Levin CS, Buvat I, Iagaru A, Hermann K, Badawi RD, Cherry SR, Bradley KM, et al. New PET technologies–embracing progress and pushing the limits. European journal of nuclear medicine and molecular imag�ing 2021;48:2711–26. 80. Hatt M, Le Rest CC, Tixier F, Badic B, Schick U, and Visvikis D. Radiomics: data are also images. Journal of Nuclear Medicine 2019;60:38S–44S. 81. Lee JS. A review of deep-learning-based approaches for attenuation correction in positron emission tomography. IEEE Transactions on Radiation and Plasma Med�ical Sciences 2020;5:160–84. 82. Reader AJ, Corda G, Mehranian A, Costa-Luis C da, Ellis S, and Schnabel JA. Deep learning for PET image reconstruction. IEEE Transactions on Radiation and Plasma Medical Sciences 2020;5:1–25. 130 83. Zhao YM, Li YH, Chen T, Zhang WG, Wang LH, Feng J, Li C, Zhang X, Fan W, and Hu YY. Image quality and lesion detectability in low-dose pediatric 18F�FDG scans using total-body PET/CT. European journal of nuclear medicine and molecular imaging 2021;48:3378–85. 84. Nadig V, Herrmann K, Mottaghy FM, and Schulz V. Hybrid total-body pet scan�ners—current status and future perspectives. European journal of nuclear medicine and molecular imaging 2022;49:445–59. 85. Van der Geest K, Treglia G, Glaudemans A, Brouwer E, Sandovici M, Jamar F, Gheysens O, and Slart R. Diagnostic value of [18F] FDG-PET/CT for treatment monitoring in large vessel vasculitis: a systematic review and meta-analysis. Euro�pean journal of nuclear medicine and molecular imaging 2021;48:3886–902. 86. Lodge MA. Repeatability of SUV in oncologic 18F-FDG PET. Journal of Nuclear Medicine 2017;58:523–32. 87. Praagh GD van, Nienhuis PH, Jong DM de, Reijrink M, Geest KSM van der, Brouwer E, Glaudemans AWJM, Sinha B, Willemsen ATM, and Slart RHJA. To�ward Reliable Uptake Metrics in Large Vessel Vasculitis Studies. Diagnostics 2021;11. 88. Wahl RL, Jacene H, Kasamon Y, and Lodge MA. From RECIST to PERCIST: evolving considerations for PET response criteria in solid tumors. Journal of nu�clear medicine 2009;50:122S–150S. 89. Schwartz J, Humm J, Gonen M, Kalaigian H, Schoder H, Larson S, and Nehmeh S. Repeatability of SUV measurements in serial PET. Medical physics 2011;38:2629– 38. 90. Fletcher J and Kinahan P. PET/CT standardized uptake values (SUVs) in clinical practice and assessing response to therapy. NIH Public Access 2010;31:496–505. 91. Adams MC, Turkington TG, Wilson JM, and Wong TZ. A systematic review of the factors affecting accuracy of SUV measurements. American Journal of Roentgenol�ogy 2010;195:310–20. 131 92. Eskian M, Alavi A, Khorasanizadeh M, Viglianti BL, Jacobsson H, Barwick TD, Meysamie A, Yi SK, Iwano S, Bybel B, et al. Effect of blood glucose level on standardized uptake value (SUV) in 18F-FDG PET-scan: a systematic review and meta-analysis of 20,807 individual SUV measurements. European journal of nu�clear medicine and molecular imaging 2019;46:224–37. 93. Iking J, Staniszewska M, Kessler L, Klose JM, Luckerath K, Fendler WP, Her- ¨ rmann K, and Rischpler C. Imaging inflammation with positron emission tomog�raphy. Biomedicines 2021;9:212. 94. Pelletier-Galarneau M and Ruddy TD. PET/CT for diagnosis and management of large-vessel vasculitis. Current cardiology reports 2019;21:34. 95. Nielsen BD, Hansen IT, Kramer S, Haraldsen A, Hjorthaug K, Bogsrud TV, Ejlersen JA, Stolle LB, Keller KK, Therkildsen P, et al. Simple dichotomous assessment of cranial artery inflammation by conventional 18F-FDG PET/CT shows high accu�racy for the diagnosis of giant cell arteritis: a case-control study. European Journal of Nuclear Medicine and Molecular Imaging 2019;46:184–93. 96. Patel PY, Dalal I, and Griffith B. [18F] FDG-PET Evaluation of Spinal Pathology in Patients in Oncology: Pearls and Pitfalls for the Neuroradiologist. American Journal of Neuroradiology 2022;43:332–40. 97. Lee SW, Kim SJ, Seo Y, Jeong SY, Ahn BC, and Lee J. F-18 FDG PET for as�sessment of disease activity of large vessel vasculitis: A systematic review and meta-analysis. Journal of Nuclear Cardiology 2019;26:59–67. 98. Veeranna V, Fisher A, Nagpal P, Ghosh N, Fisher E, Steigner M, Creager MA, Dorbala S, and Di Carli MF. Utility of multimodality imaging in diagnosis and follow-up of aortitis. Journal of Nuclear Cardiology 2016;23:590–5. 99. Vaidyanathan S, Patel C, Scarsbrook A, and Chowdhury F. FDG PET/CT in infec�tion and inflammation—current and emerging clinical applications. Clinical radi�ology 2015;70:787–800. 100. Chen Z, Liu M, Li L, and Chen L. Involvement of the Warburg effect in non-tumor diseases processes. Journal of cellular physiology 2018;233:2839–49. 132 101. Jacobson O, Kiesewetter DO, and Chen X. Fluorine-18 radiochemistry, labeling strategies and synthetic routes. Bioconjugate chemistry 2015;26:1–18. 102. Yu S. Review of 18F-FDG synthesis and quality control. Biomedical imaging and intervention journal 2006;2. 103. Fludeoxyglucose F 18 injection (FDG): Uses, dosage, side effects, interactions, warning. 2022. URL: https: // www. rxlist. com/fludeoxyglucose - drug. htm#indications. 104. Walter MA, Melzer RA, Schindler C, Muller-Brand J, Tyndall A, and Nitzsche EU. ¨ The value of [18 F] FDG-PET in the diagnosis of large-vessel vasculitis and the assessment of activity and extent of disease. European journal of nuclear medicine and molecular imaging 2005;32:674–81. 105. Nielsen BD, Gormsen LC, Hansen IT, Keller KK, Therkildsen P, and Hauge EM. Three days of high-dose glucocorticoid treatment attenuates large-vessel 18F-FDG uptake in large-vessel giant cell arteritis but with a limited impact on diagnostic ac�curacy. European journal of nuclear medicine and molecular imaging 2018;45:1119– 28. 106. Fuchs M, Briel M, Daikeler T, Walker UA, Rasch H, Berg S, Ng QK, Raatz H, Jayne D, Kotter I, et al. The impact of 18 F-FDG PET on the management of pa- ¨ tients with suspected large vessel vasculitis. European journal of nuclear medicine and molecular imaging 2012;39:344–53. 107. Stellingwerff MD, Brouwer E, Lensen KJD, Rutgers A, Arends S, Van Der Geest KS, Glaudemans AW, and Slart RH. Different scoring methods of FDG PET/CT in giant cell arteritis: need for standardization. Medicine 2015;94. 108. Grayson PC, Alehashemi S, Bagheri AA, Civelek AC, Cupps TR, Kaplan MJ, Malayeri AA, Merkel PA, Novakovich E, Bluemke DA, et al. 18F-fluorodeoxyglucose– positron emission tomography as an imaging biomarker in a prospective, longi�tudinal cohort of patients with large vessel vasculitis. Arthritis & Rheumatology 2018;70:439–49. 133 109. Kang F, Han Q, Zhou X, Zheng Z, Wang S, Ma W, Zhang K, Quan Z, Yang W, Wang J, et al. Performance of the PET vascular activity score (PETVAS) for qual�itative and quantitative assessment of inflammatory activity in Takayasu’s arteritis patients. European journal of nuclear medicine and molecular imaging 2020:1–11. 110. Quinn KA, Dashora H, Novakovich E, Ahlman MA, and Grayson PC. Use of 18F�fluorodeoxyglucose positron emission tomography to monitor tocilizumab effect on vascular inflammation in giant cell arteritis. Rheumatology 2021;60:4384–9. 111. Mackie SL, Dejaco C, Appenzeller S, Camellino D, Duftner C, Gonzalez-Chiappe S, Mahr A, Mukhtyar C, Reynolds G, De Souza AWS, et al. British Society for Rheumatology guideline on diagnosis and treatment of giant cell arteritis. Rheuma�tology 2020;59:e1–e23. 112. Versari A, Pipitone N, Casali M, Jamar F, and Pazzola G. Use of imaging tech�niques in large vessel vasculitis and related conditions. The quarterly journal of nuclear medicine and molecular imaging: official publication of the Italian Asso�ciation of Nuclear Medicine (AIMN)[and] the International Association of Radio�pharmacology (IAR),[and] Section of the Society of 2018;62:34–9. 113. Grayson PC, Alehashemi S, Bagheri AA, Civelek AC, Cupps TR, Kaplan MJ, Malayeri AA, Merkel PA, Novakovich E, Bluemke DA, et al. Positron emission to�mography as an imaging biomarker in a prospective, longitudinal cohort of patients with large vessel vasculitis. Arthritis & rheumatology (Hoboken, NJ) 2018;70:439. 114. Dashora HR, Rosenblum JS, Quinn KA, Alessi H, Novakovich E, Saboury B, Ahlman MA, and Grayson P. Comparing semi-quantitative and qualitative meth�ods of vascular FDG-PET activity measurement in large-vessel vasculitis. Journal of Nuclear Medicine 2021. 115. Laffon E and Marthan R. On Semi-quantitative Methods for Assessing Vascular 18FDG-PET Activity in Large-Vessels Vasculitis. Journal of Nuclear Medicine 2021. 134 116. Dellavedova L, Carletto M, Faggioli P, Sciascera A, Del Sole A, Mazzone A, and Maffioli L. The prognostic value of baseline 18 F-FDG PET/CT in steroid-naıve large-vessel vasculitis: introduction of volume-based parameters. European journal of nuclear medicine and molecular imaging 2016;43:340–8. 117. Motwani M. Hiding beyond plain sight: Textural analysis of positron emission tomography to identify high-risk plaques in carotid atherosclerosis. 2019. 118. Hatt M, Le Rest CC, Antonorsi N, Tixier F, Tankyevych O, Jaouen V, Lucia F, Bourbonne V, Schick U, Badic B, et al. Radiomics in PET/CT: current status and future AI-based evolutions. In: Seminars in Nuclear Medicine. Vol. 51. 2. Elsevier. 2021:126–33. 119. Lambin P, Rios-Velazquez E, Leijenaar R, Carvalho S, Van Stiphout RG, Granton P, Zegers CM, Gillies R, Boellard R, Dekker A, et al. Radiomics: extracting more information from medical images using advanced feature analysis. European jour�nal of cancer 2012;48:441–6. 120. O’Sullivan F, Roy S, and Eary J. A statistical measure of tissue heterogeneity with application to 3D PET sarcoma data. Biostatistics 2003;4:433–48. 121. El Naqa I, Grigsby PW, Apte A, Kidd E, Donnelly E, Khullar D, Chaudhari S, Yang D, Schmitt M, Laforest R, et al. Exploring feature-based approaches in PET images for predicting cancer treatment outcomes. Pattern recognition 2009;42:1162–71. 122. Galavis PE, Hollensen C, Jallow N, Paliwal B, and Jeraj R. Variability of textural features in FDG PET images due to different acquisition modes and reconstruction parameters. Acta oncologica 2010;49:1012–6. 123. Strand R, Malmberg F, Johansson L, Lind L, Sundbom M, Ahlstrom H, and Kull- ¨ berg J. A concept for holistic whole body MRI data analysis, Imiomics. PloS one 2017;12:e0169966. 124. Visvikis D, Le Rest CC, Jaouen V, and Hatt M. Artificial intelligence, machine (deep) learning and radio (geno) mics: definitions and nuclear medicine imag�ing applications. European Journal of Nuclear Medicine and Molecular Imaging 2019:1–8. 135 125. Duff L and Tsoumpas C. Automated diagnosis and prediction in cardiovascular diseases using tomographic imaging. 126. Visvikis D, Lambin P, Beuschau Mauridsen K, Hustinx R, Lassmann M, Rischpler C, Shi K, and Pruim J. Application of artificial intelligence in nuclear medicine and molecular imaging: a review of current status and future perspectives for clinical translation. European journal of nuclear medicine and molecular imaging 2022:1– 12. 127. Zhuang F, Qi Z, Duan K, Xi D, Zhu Y, Zhu H, Xiong H, and He Q. A comprehen�sive survey on transfer learning. Proceedings of the IEEE 2020;109:43–76. 128. Shorten C and Khoshgoftaar TM. A survey on image data augmentation for deep learning. Journal of big data 2019;6:1–48. 129. Park JE, Park SY, Kim HJ, and Kim HS. Reproducibility and generalizability in radiomics modeling: possible strategies in radiologic and statistical perspectives. Korean journal of radiology 2019;20:1124–37. 130. Slart RH, Williams MC, Juarez-Orozco LE, Rischpler C, Dweck MR, Glaudemans AW, Gimelli A, Georgoulias P, Gheysens O, Gaemperli O, et al. Position paper of the EACVI and EANM on artificial intelligence applications in multimodality car�diovascular imaging using SPECT/CT, PET/CT, and cardiac CT. European journal of nuclear medicine and molecular imaging 2021;48:1399–413. 131. Lovinfosse P, Visvikis D, Hustinx R, and Hatt M. FDG PET radiomics: a review of the methodological aspects. Clinical and Translational Imaging 2018;6:379–91. 132. Ferreira M, Lovinfosse P, Hermesse J, Decuypere M, Rousseau C, Lucia F, Schick U, Reinhold C, Robin P, Hatt M, et al. Comparison of radiomic pre-processing steps in the reproducible prediction of disease free survival across multi-scanners / centers. 2021. 133. Chen L, Li S, Bai Q, Yang J, Jiang S, and Miao Y. Review of image classification algorithms based on convolutional neural networks. Remote Sensing 2021;13:4712. 134. Sarvamangala D and Kulkarni RV. Convolutional neural networks in medical im�age understanding: a survey. Evolutionary intelligence 2022;15:1–22. 136 135. Shiri I, Rahmim A, Ghaffarian P, Geramifar P, Abdollahi H, and Bitarafan-Rajabi A. The impact of image reconstruction settings on 18F-FDG PET radiomic fea�tures: multi-scanner phantom and patient studies. European radiology 2017;27:4498– 509. 136. Pfaehler E, Beukinga RJ, Jong JR de, Slart RH, Slump CH, Dierckx RA, and Boel�laard R. Repeatability of 18F-FDG PET radiomic features: A phantom study to explore sensitivity to image reconstruction settings, noise, and delineation method. Medical physics 2019;46:665–78. 137. Reader AJ and Zaidi H. Advances in PET image reconstruction. PET clinics 2007;2:173– 90. 138. Yan J, Chu-Shern JL, Loi HY, Khor LK, Sinha AK, Quek ST, Tham IW, and Townsend D. Impact of image reconstruction settings on texture features in 18F�FDG PET. Journal of nuclear medicine 2015;56:1667–73. 139. Zwanenburg A, Vallieres M, Abdalah MA, Aerts HJ, Andrearczyk V, Apte A, ` Ashrafinia S, Bakas S, Beukinga RJ, Boellaard R, et al. The image biomarker standardization initiative: standardized quantitative radiomics for high-throughput image-based phenotyping. Radiology 2020;295:328. 140. Mali SA, Ibrahim A, Woodruff HC, Andrearczyk V, Muller H, Primakov S, Salahud- ¨ din Z, Chatterjee A, and Lambin P. Making radiomics more reproducible across scanner and imaging protocol variations: a review of harmonization methods. Jour�nal of Personalized Medicine 2021;11:842. 141. Da-Ano R, Visvikis D, and Hatt M. Harmonization strategies for multicenter ra�diomics investigations. Physics in Medicine & Biology 2020;65:24TR02. 142. Gatys LA, Ecker AS, and Bethge M. Image style transfer using convolutional neu�ral networks. In: Proceedings of the IEEE conference on computer vision and pat�tern recognition. 2016:2414–23. 143. Hognon C, Tixier F, Gallinato O, Colin T, Visvikis D, and Jaouen V. Standardiza�tion of multicentric image datasets with generative adversarial networks. In: IEEE Nuclear Science Symposium and Medical Imaging Conference 2019. 2019. 137 144. Modanwal G, Vellal A, Buda M, and Mazurowski MA. MRI image harmonization using cycle-consistent generative adversarial network. In: Medical Imaging 2020: Computer-Aided Diagnosis. Vol. 11314. SPIE. 2020:259–64. 145. Shah J, Gao F, Li B, Ghisays V, Luo J, Chen Y, Lee W, Zhou Y, Benzinger TL, Reiman EM, et al. Deep residual inception encoder-decoder network for amyloid PET harmonization. Alzheimer’s & Dementia 2022. 146. Da-Ano R, Masson I, Lucia F, Dore M, Robin P, Alfieri J, Rousseau C, Mervoyer ´ A, Reinhold C, Castelli J, et al. Performance comparison of modified ComBat for harmonization of radiomic features for multicenter studies. Scientific Reports 2020;10:1–12. 147. Papadimitroulas P, Brocki L, Chung NC, Marchadour W, Vermet F, Gaubert L, Eleftheriadis V, Plachouris D, Visvikis D, Kagadis GC, et al. Artificial intelligence: Deep learning in oncological radiomics and challenges of interpretability and data harmonization. Physica Medica 2021;83:108–21. 148. Orlhac F, Boughdad S, Philippe C, Stalla-Bourdillon H, Nioche C, Champion L, Soussan M, Frouin F, Frouin V, and Buvat I. A postreconstruction harmoniza�tion method for multicenter radiomic studies in PET. Journal of Nuclear Medicine 2018;59:1321–8. 149. Johnson WE, Li C, and Rabinovic A. Adjusting batch effects in microarray expres�sion data using empirical Bayes methods. Biostatistics 2007;8:118–27. 150. Fortin JP, Cullen N, Sheline YI, Taylor WD, Aselcioglu I, Cook PA, Adams P, Cooper C, Fava M, McGrath PJ, et al. Harmonization of cortical thickness mea�surements across scanners and sites. Neuroimage 2018;167:104–20. 151. Timmeren JE van, Cester D, Tanadini-Lang S, Alkadhi H, and Baessler B. Ra�diomics in medical imaging—“How-to” guide and critical reflection. Insights into Imaging 2020;11:1–16. 138 152. Shafiq-ul-Hassan M, Zhang GG, Latifi K, Ullah G, Hunt DC, Balagurunathan Y, Abdalah MA, Schabath MB, Goldgof DG, Mackin D, et al. Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels. Medical physics 2017;44:1050–62. 153. Leijenaar RT, Nalbantov G, Carvalho S, Van Elmpt WJ, Troost EG, Boellaard R, Aerts HJ, Gillies RJ, and Lambin P. The effect of SUV discretization in quantita�tive FDG-PET Radiomics: the need for standardized methodology in tumor texture analysis. Scientific reports 2015;5:1–10. 154. Gallivanone F, Interlenghi M, D’Ambrosio D, Trifiro G, and Castiglioni I. Pa- ` rameters influencing PET imaging features: a phantom study with irregular and heterogeneous synthetic lesions. Contrast media & molecular imaging 2018;2018. 155. Altazi BA, Zhang GG, Fernandez DC, Montejo ME, Hunt D, Werner J, Biagi�oli MC, and Moros EG. Reproducibility of F18-FDG PET radiomic features for different cervical tumor segmentation methods, gray-level discretization, and re�construction algorithms. Journal of applied clinical medical physics 2017;18:32– 48. 156. Piri R, Edenbrandt L, Larsson M, Enqvist O, Nøddeskou-Fink AH, Gerke O, and Høilund-Carlsen PF. Aortic wall segmentation in 18F-sodium fluoride PET/CT scans: Head-to-head comparison of artificial intelligence-based versus manual seg�mentation. Journal of Nuclear Cardiology 2022;29:2001–10. 157. Reinke A, Tizabi MD, Sudre CH, Eisenmann M, Radsch T, Baumgartner M, Acion ¨ L, Antonelli M, Arbel T, Bakas S, et al. Common limitations of image processing metrics: A picture story. arXiv preprint arXiv:2104.05642 2021. 158. Sedghi Gamechi Z, Bons LR, Giordano M, Bos D, Budde RP, Kofoed KF, Peder�sen JH, Roos-Hesselink JW, and Bruijne M de. Automated 3D segmentation and diameter measurement of the thoracic aorta on non-contrast enhanced CT. Euro�pean radiology 2019;29:4613–23. 159. Rahman H, Rahman S, and Din F. Automatic segmentation of the aorta in cardiac medical images. The Nucleus 2017;54:90–6. 139 160. Florez E, Fatemi A, Claudio PP, and Howard CM. Emergence of radiomics: novel methodology identifying imaging biomarkers of disease in diagnosis, response, and progression. SM journal of clinical and medical imaging 2018;4. 161. Jin Y, Pepe A, Li J, Gsaxner C, Zhao Fh, Kleesiek J, Frangi AF, and Egger J. Ai�based aortic vessel tree segmentation for cardiovascular diseases treatment: status quo. arXiv preprint arXiv:2108.02998 2021. 162. Noothout JM, De Vos BD, Wolterink JM, and Isgum I. Automatic segmentation of ˇ thoracic aorta segments in low-dose chest CT. In: Medical Imaging 2018: Image Processing. Vol. 10574. International Society for Optics and Photonics. 2018:105741S. 163. Ronneberger O, Fischer P, and Brox T. U-net: Convolutional networks for biomed�ical image segmentation. In: International Conference on Medical image comput�ing and computer-assisted intervention. Springer. 2015:234–41. 164. Mohammadi S, Mohammadi M, Dehlaghi V, and Ahmadi A. Automatic segmen�tation, detection, and diagnosis of abdominal aortic aneurysm (AAA) using convo�lutional neural networks and hough circles algorithm. Cardiovascular Engineering and Technology 2019;10:490–9. 165. Jha D, Riegler MA, Johansen D, Halvorsen P, and Johansen HD. Doubleu-net: A deep convolutional neural network for medical image segmentation. In: 2020 IEEE 33rd International symposium on computer-based medical systems (CBMS). IEEE. 2020:558–64. 166. Bonechi S, Andreini P, Mecocci A, Giannelli N, Scarselli F, Neri E, Bianchini M, and Dimitri GM. Segmentation of Aorta 3D CT Images Based on 2D Convolu�tional Neural Networks. Electronics 2021;10:2559. 167. Hahn LD, Baeumler K, and Hsiao A. Artificial intelligence and machine learning in aortic disease. Current Opinion in Cardiology 2021;36:695–703. 168. Xie Y, Padgett J, Biancardi AM, and Reeves AP. Automated aorta segmentation in low-dose chest CT images. International journal of computer assisted radiology and surgery 2014;9:211–9. 140 169. Egger J, Freisleben B, Setser R, Renapuraar R, Biermann C, and O’Donnell T. Aorta segmentation for stent simulation. arXiv preprint arXiv:1103.1773 2011. 170. Subasic M, Loncaric S, and Sorantin E. Region-based deformable model for aortic wall segmentation. In: 3rd International Symposium on Image and Signal Process�ing and Analysis, 2003. ISPA 2003. Proceedings of the. Vol. 2. IEEE. 2003:731– 5. 171. Brooks FJ and Grigsby PW. The effect of small tumor volumes on studies of intra�tumoral heterogeneity of tracer uptake. Journal of Nuclear Medicine 2014;55:37– 42. 172. Hatt M, Vallieres M, Visvikis D, and Zwanenburg A. IBSI: an international com�munity radiomics standardization initiative. 2018. 173. Nioche C, Orlhac F, Boughdad S, Reuze S, Goya-Outi J, Robert C, Pellot-Barakat ´ C, Soussan M, Frouin F, and Buvat I. LIFEx: a freeware for radiomic feature cal�culation in multimodality imaging to accelerate advances in the characterization of tumor heterogeneity. Cancer research 2018;78:4786–9. 174. Korte JC, Cardenas C, Hardcastle N, Kron T, Wang J, Bahig H, Elgohari B, Ger R, Court L, Fuller CD, et al. Radiomics feature stability of open-source software evaluated on apparent diffusion coefficient maps in head and neck cancer. Scien�tific reports 2021;11:1–11. 175. Van Griethuysen JJ, Fedorov A, Parmar C, Hosny A, Aucoin N, Narayan V, Beets�Tan RG, Fillion-Robin JC, Pieper S, and Aerts HJ. Computational radiomics sys�tem to decode the radiographic phenotype. Cancer research 2017;77:e104–e107. 176. Song J, Yin Y, Wang H, Chang Z, Liu Z, and Cui L. A review of original arti�cles published in the emerging field of radiomics. European journal of radiology 2020;127:108991. 177. Pfaehler E, Zhovannik I, Wei L, Boellaard R, Dekker A, Monshouwer R, El Naqa I, Bussink J, Gillies R, Wee L, et al. A systematic review and quality of reporting checklist for repeatability and reproducibility of radiomic features. Physics and imaging in radiation oncology 2021;20:69–75. 141 178. Lorbeer R, Grotz A, Dorr M, V ¨ olzke H, Lieb W, K ¨ uhn JP, and Mensel B. Ref- ¨ erence values of vessel diameters, stenosis prevalence, and arterial variations of the lower limb arteries in a male population sample using contrast-enhanced MR angiography. PLoS One 2018;13:e0197559. 179. Samarzija K, Milosevic P, Jurjevic Z, and Erdeljac E. Grading of carotid artery stenosis with computed tomography angiography: whether to use the narrowest diameter or the cross-sectional area. Insights into Imaging 2018;9:527–34. 180. Olson SL, Wijesinha MA, Panthofer AM, Blackwelder WC, Upchurch GR, Terrin ML, Curci JA, Baxter BT, and Matsumura JS. Evaluating growth patterns of ab�dominal aortic aneurysm diameter with serial computed tomography surveillance. JAMA surgery 2021;156:363–70. 181. Polak JF, Kronmal RA, Tell GS, O’Leary DH, Savage PJ, Gardin JM, Rutan GH, and Borhani NO. Compensatory increase in common carotid artery diameter: re�lation to blood pressure and artery intima-media thickness in older adults. Stroke 1996;27:2012–5. 182. Thapar A, Cheal D, Hopkins T, Ward S, Shaloub J, and Yusuf S. Internal or external wall diameter for abdominal aortic aneurysm screening? The Annals of The Royal College of Surgeons of England 2010;92:503–5. 183. Olive DJ. Principal component analysis. In: Robust multivariate analysis. Springer, 2017:189–217. 184. Fawcett T. An introduction to ROC analysis. Pattern recognition letters 2006;27:861– 74. 185. Leevy JL, Khoshgoftaar TM, Bauder RA, and Seliya N. A survey on addressing high-class imbalance in big data. Journal of Big Data 2018;5:1–30. 186. Klawonn F, Hoppner F, and May S. An alternative to ROC and AUC analysis of ¨ classifiers. In: Advances in Intelligent Data Analysis X: 10th International Sympo�sium, IDA 2011, Porto, Portugal, October 29-31, 2011. Proceedings 10. Springer. 2011:210–21. 142 187. Provost F and Fawcett T. Robust classification for imprecise environments. Ma�chine learning 2001;42:203–31. 188. Ling CX, Huang J, Zhang H, et al. AUC: a statistically consistent and more dis�criminating measure than accuracy. In: Ijcai. Vol. 3. 2003:519–24. 189. Halligan S, Altman DG, and Mallett S. Disadvantages of using the area under the receiver operating characteristic curve to assess imaging tests: a discussion and proposal for an alternative approach. European radiology 2015;25:932–9. 190. Harrington MB. Some methodological questions concerning receiver operating characteristic (ROC) analysis as a method for assessing image quality in radiol�ogy. Journal of digital imaging 1990;3:211–8. 191. Chalkidou A, O’Doherty MJ, and Marsden PK. False discovery rates in PET and CT studies with texture features: a systematic review. PloS one 2015;10:e0124165. 192. O’Connor JP, Aboagye EO, Adams JE, Aerts HJ, Barrington SF, Beer AJ, Boel�laard R, Bohndiek SE, Brady M, Brown G, et al. Imaging biomarker roadmap for cancer studies. Nature reviews Clinical oncology 2017;14:169–86. 193. Vallieres M, Zwanenburg A, Badic B, Le Rest CC, Visvikis D, and Hatt M. Re- ` sponsible radiomics research for faster clinical translation. 2018. 194. Collins GS, Reitsma JB, Altman DG, and Moons KG. Transparent reporting of a multivariable prediction model for individual prognosis or diagnosis (TRIPOD): the TRIPOD statement. Journal of British Surgery 2015;102:148–58. 195. Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig L, Lijmer JG, Moher D, Rennie D, De Vet HC, et al. STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. Clinical chemistry 2015;61:1446– 52. 196. Chen C, Grennan K, Badner J, Zhang D, Gershon E, Jin L, and Liu C. Removing batch effects in analysis of expression microarray data: an evaluation of six batch adjustment methods. PloS one 2011;6:e17238. 143 197. Jochems A, Deist TM, Van Soest J, Eble M, Bulens P, Coucke P, Dries W, Lambin P, and Dekker A. Distributed learning: developing a predictive model based on data from multiple hospitals without data leaving the hospital–a real life proof of concept. Radiotherapy and Oncology 2016;121:459–67. 198. Zerka F, Barakat S, Walsh S, Bogowicz M, Leijenaar RT, Jochems A, Miraglio B, Townend D, and Lambin P. Systematic review of privacy-preserving distributed machine learning from federated databases in health care. JCO clinical cancer in�formatics 2020;4:184–200. 199. Michael JR, Stanley C, Adamson R, and Kotevska O. Addressing the Limitations to Distributed Learning Containing Sensitive Data. 200. Verbraeken J, Wolting M, Katzy J, Kloppenburg J, Verbelen T, and Rellermeyer JS. A survey on distributed machine learning. Acm computing surveys (csur) 2020;53:1– 33. 201. Ford RA, Price W, and Nicholson I. Privacy and accountability in black-box medicine. Mich. Telecomm. & Tech. L. Rev. 2016;23:1. 202. Wang S, Dong D, Li L, Li H, Bai Y, Hu Y, Huang Y, Yu X, Liu S, Qiu X, et al. A deep learning radiomics model to identify poor outcome in COVID-19 patients with underlying health conditions: A multicenter study. IEEE Journal of Biomedi�cal and Health Informatics 2021;25:2353–62. 203. Wennmann M, Klein A, Bauer F, Chmelik J, Grozinger M, Uhlenbrock C, Lochner ¨ J, Nonnenmacher T, Rotkopf LT, Sauer S, et al. Combining deep learning and radiomics for automated, objective, comprehensive bone marrow characterization from whole-body MRI: a multicentric feasibility study. Investigative Radiology 2022;57:752–63. 204. Brown P, Zhong J, Frood R, Currie S, Gilbert A, Appelt A, Sebag-Montefiore D, and Scarsbrook A. Prediction of outcome in anal squamous cell carcinoma using radiomic feature analysis of pre-treatment FDG PET-CT. European journal of nu�clear medicine and molecular imaging 2019;46:2790–9. 144 205. Boellaard R, Delgado-Bolton R, Oyen WJ, Giammarile F, Tatsch K, Eschner W, Verzijlbergen FJ, Barrington SF, Pike LC, Weber WA, et al. FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0. European journal of nuclear medicine and molecular imaging 2015;42:328–54. 206. Kikinis R, Pieper SD, and Vosburgh KG. 3D Slicer: a platform for subject-specific image analysis, visualization, and clinical support. In: Intraoperative imaging and image-guided therapy. Springer, 2014:277–89. 207. Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M, et al. 3D Slicer as an image comput�ing platform for the Quantitative Imaging Network. Magnetic resonance imaging 2012;30:1323–41. 208. Steyerberg EW. Validation in prediction research: the waste by data splitting. Jour�nal of clinical epidemiology 2018;103:131–3. 209. Langs G, Rohrich S, Hofmanninger J, Prayer F, Pan J, Herold C, and Prosch ¨ H. Machine learning: from radiomics to discovery and routine. Der Radiologe 2018;58:1–6. 210. Nappi C and Cuocolo A. The machine learning approach: Artificial intelligence is coming to support critical clinical thinking. 2020. 211. Shrestha S and Sengupta PP. Machine learning for nuclear cardiology: The way forward. 2019. 212. Lodge MA, Chaudhry MA, and Wahl RL. Noise considerations for PET quantifi�cation using maximum and peak standardized uptake value. Journal of Nuclear Medicine 2012;53:1041–7. 213. Duff L, Scarsbrook AF, Mackie SL, Frood R, Bailey M, Morgan AW, and Tsoumpas C. A methodological framework for AI-assisted diagnosis of active aortitis using Radiomic analysis of FDG PET–CT Images: Initial analysis. Journal of Nuclear Cardiology 2022. 214. Hatt M, Lucia F, Schick U, and Visvikis D. Multicentric validation of radiomics findings: challenges and opportunities. EBioMedicine 2019;47:20–1. 145 215. Duff LM, Scarsbrook AF, Ravikumar N, Frood R, Praagh GD van, Mackie SL, Bailey MA, Tarkin JM, Mason JC, Geest KS van der, et al. An Automated Method for Artifical Intelligence Assisted Diagnosis of Active Aortitis Using Radiomic Analysis of FDG PET-CT Images. Biomolecules 2023;13:343. 216. LIDA. Target. Last accessed 1st April 2022. 2022. URL: https://lida.leeds. ac.uk/target/. 217. Dice LR. Measures of the amount of ecologic association between species. Ecol�ogy 1945;26:297–302. 218. Van Griethuysen JJ, Fedorov A, Parmar C, Hosny A, Aucoin N, Narayan V, Beets�Tan RG, Fillion-Robin JC, Pieper S, and Aerts HJ. Computational radiomics sys�tem to decode the radiographic phenotype. Cancer research 2017;77:e104–e107. 219. Xing H, Hao Z, Zhu W, Sun D, Ding J, Zhang H, Liu Y, and Huo L. Preoper�ative prediction of pathological grade in pancreatic ductal adenocarcinoma based on 18F-FDG PET/CT radiomics. EJNMMI research 2021;11:1–10. 220. Sun X and Xu W. Fast implementation of DeLong’s algorithm for comparing the areas under correlated receiver operating characteristic curves. IEEE Signal Pro�cessing Letters 2014;21:1389–93. 221. DeLong ER, DeLong DM, and Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988:837–45. 222. Larue RT, Defraene G, De Ruysscher D, Lambin P, and Van Elmpt W. Quantitative radiomics studies for tissue characterization: a review of technology and method�ological procedures. The British journal of radiology 2017;90:20160665. 223. Lopez-Linares K, Garcıa I, Garcıa-Familiar A, Macıa I, and Ballester MAG. 3D ´ convolutional neural network for abdominal aortic aneurysm segmentation. arXiv preprint arXiv:1903.00879 2019. 224. Sollini M, Antunovic L, Chiti A, and Kirienko M. Towards clinical application of image mining: a systematic review on artificial intelligence and radiomics. Euro�pean journal of nuclear medicine and molecular imaging 2019:1–17. 146 225. Ronrick Da, Lucia F, Masson I, Abgral R, Alfieri J, Rousseau C, Mervoyer A, Reinhold C, Pradier O, Schick U, et al. Pre-selecting radiomic features based on their robustness to changes in imaging properties of multicentre data: impact on predictive modelling performance compared to ComBat harmonization of all avail�able features. 2021. 226. Schlett C, Hendel T, Weckbach S, Reiser M, Kauczor H, Nikolaou K, Gunther M, ¨ Forsting M, Hosten N, Volzke H, et al. Population-based imaging and radiomics: ¨ rationale and perspective of the German National Cohort MRI Study. In: RoFo- ¨ Fortschritte auf dem Gebiet der Rontgenstrahlen und der bildgebenden Verfahren ¨ . Vol. 188. 07. © Georg Thieme Verlag KG. 2016:652–61. 227. Traverso A, Wee L, Dekker A, and Gillies R. Repeatability and reproducibility of radiomic features: a systematic review. International Journal of Radiation Oncol�ogy* Biology* Physics 2018;102:1143–58. 228. Fei JL, Pu CL, Xu FY, Wu Y, and Hu HJ. Progress in radiomics of common heart disease based on cardiac magnetic resonance imaging. Journal of Molecular and Clinical Medicine 2021;4:29–38. 229. Juarez-Orozco LE, Martinez-Manzanera O, Zant FM van der, Knol RJ, and Knuuti J. Deep learning in quantitative PET myocardial perfusion imaging: a study on cardiovascular event prediction. Cardiovascular Imaging 2020;13:180–2. 230. Kwiecinski J, Kolossvary M, Tzolos E, Meah M, Adamson P, Joshi N, Williams M, Van Beek E, Berman D, Maurovich-Horvat P, et al. 18F-sodium fluoride positron emission tomography and coronary plaque radiomics derived from computed to�mography angiography for prediction of myocardial infarction. European Heart Journal 2022;43:ehac544–212. 231. Yip SS and Aerts HJ. Applications and limitations of radiomics. Physics in Medicine & Biology 2016;61:R150. 232. Ibrahim A, Primakov S, Barufaldi B, Acciavatti RJ, Granzier RW, Hustinx R, Mot�taghy FM, Woodruff HC, Wildberger JE, Lambin P, et al. The effects of in-plane 147 spatial resolution on CT-based radiomic features’ stability with and without Com�Bat harmonization. Cancers 2021;13:1848. 233. Orlhac F and Buvat I. Comment on Ibrahim et al. The Effects of In-Plane Spatial Resolution on CT-Based Radiomic Features’ Stability with and without ComBat Harmonization. Cancers 2021, 13, 1848. Cancers 2021;13:3037. 234. Orlhac F, Eertink JJ, Cottereau AS, Zijlstra JM, Thieblemont C, Meignan MA, Boellaard R, and Buvat I. A guide to ComBat harmonization of imaging biomark�ers in multicenter studies. Journal of Nuclear Medicine 2021. 235. Bettinelli A, Marturano F, Avanzo M, Loi E, Menghi E, Mezzenga E, Pirrone G, Sarnelli A, Strigari L, Strolin S, and Paiusco M. A Novel Benchmarking Ap�proach to Assess the Agreement among Radiomic Tools. Radiology 0000;0. PMID: 35230182:211604. 236. Carles M, Fechter T, Martı-Bonmatı L, Baltas D, and Mix M. Experimental phan�tom evaluation to identify robust positron emission tomography (PET) radiomic features. EJNMMI physics 2021;8:1–17. 237. Oliveira C, Amstutz F, Vuong D, Bogowicz M, Hullner M, Foerster R, Basler L, ¨ Schroder C, Eboulet EI, Pless M, et al. Preselection of robust radiomic features ¨ does not improve outcome modelling in non-small cell lung cancer based on clini�cal routine FDG-PET imaging. EJNMMI research 2021;11:1–12. 238. Toner YC, Ghotbi AA, Naidu S, Sakurai K, Leent MM van, Jordan S, Ordikhani F, Amadori L, Sofias AM, Fisher EL, et al. Systematically evaluating DOTATATE and FDG as PET immuno-imaging tracers of cardiovascular inflammation. Scientific reports 2022;12:1–15. 239. Jensen JK, Madsen JS, Jensen ME, Kjaer A, and Ripa RS. [64Cu] Cu-DOTATATE PET metrics in the investigation of atherosclerotic inflammation in humans. Jour�nal of Nuclear Cardiology 2022:1–15. 148 240. Jiemy WF, Heeringa P, Kamps JA, Laken CJ van der, Slart RH, and Brouwer E. Positron emission tomography (PET) and single photon emission computed to�mography (SPECT) imaging of macrophages in large vessel vasculitis: current sta�tus and future prospects. Autoimmunity reviews 2018;17:715–26. 241. Pugliese F, Gaemperli O, Kinderlerer AR, Lamare F, Shalhoub J, Davies AH, Rimoldi OE, Mason JC, and Camici PG. Imaging of vascular inflammation with [11C]-PK11195 and positron emission tomography/computed tomography angiog�raphy. Journal of the American College of Cardiology 2010;56:653–61. 242. Lamare F, Hinz R, Gaemperli O, Pugliese F, Mason JC, Spinks T, Camici PG, and Rimoldi OE. Detection and quantification of large-vessel inflammation with 11C-(R)-PK11195 PET/CT. Journal of Nuclear Medicine 2011;52:33–9. 243. Espitia O, Schanus J, Agard C, Kraeber-Boder´ e F, Hersant J, Serfaty JM, and Jamet ´ B. Specific features to differentiate Giant cell arteritis aortitis from aortic atheroma using FDG-PET/CT. Scientific Reports 2021;11:1–10. 244. Zerizer I, Tan K, Khan S, Barwick T, Marzola MC, Rubello D, and Al-Nahhas A. Role of FDG-PET and PET/CT in the diagnosis and management of vasculitis. European journal of radiology 2010;73:504–9. 245. Soussan M, Nicolas P, Schramm C, Katsahian S, Pop G, Fain O, and Mekinian A. Management of large-vessel vasculitis with FDG-PET: a systematic literature review and meta-analysis. Medicine 2015;94. 246. Tatsumi M, Cohade C, Nakamoto Y, and Wahl RL. Fluorodeoxyglucose uptake in the aortic wall at PET/CT: possible finding for active atherosclerosis. Radiology 2003;229:831–7. 247. Tomaszewski MR and Gillies RJ. The biological meaning of radiomic features. Radiology 2021;298:505–16"],"dcterms:accessrights":["public"],"dc:title":["Intelligent feature analysis of FDG PET-CT images for more accurate diagnosis in large vessel vasculitis"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Integrated Ph.D and Master"],"person:identifier.orcid":["0000000242956356"]},"updated_at":"2026-11-18T23:21:28Z"}