{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:32601"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:32601","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Designing Patient Specific Magnetically Actuated Tentacle Robots for Minimally Invasive Surgery","abstract":"Currently, we are limited in the tools available to reach deep inside the human body in a non-invasive manner, patients therefore may not have the option to be assessed or treated for life-threatening diseases. The long-term vision of this work is to provide surgeons with the capability to administer care with the aid of soft magnetic manipulators. The operator, needing minimally invasive access to a specific site via a complex winding pathway will be able to design personalized manipulators and fabricate them on demand. Magnetic control will allow the manipulators to be extremely soft and thin. Controlling the position of multiple anchor points along the length of the manipulator will allow shape forming for tortuous curvilinear trajectories without exerting significant pressure on surrounding tissues. Full-body control will also provide the ability to stiffen part of the manipulator to accomplish specific surgical tasks that need structural rigidity. In this thesis, this vision has been taken and soft, shape forming, magnetic manipulators have been developed. Novel modelling, simulation, optimization and fabrication techniques have been established as well as the introduction and demonstration of the concept of material reinforcement for magnetic actuation. Tentacles down to 2 mm diameter have been produced which are currently capable of semi-autonomous, low contact navigation into tortuous, soft phantoms of the digestive and respiratory anatomy - areas of the body which cannot easily be accessed using traditional minimally invasive methods. Whilst there remain many developments to be made, significant and meaningful progress has been demonstrated here on the journey towards autonomous follow-the-leader navigation. It is hoped that this work and any which develop onwards from it will continue to enable miniaturized magnetic endoluminal navigation and thus contribute to the continued progress of medical diagnostics and treatment.","abstract_html":"Currently, we are limited in the tools available to reach deep inside the human body in a non-invasive manner, patients therefore may not have the option to be assessed or treated for life-threatening diseases. The long-term vision of this work is to provide surgeons with the capability to administer care with the aid of soft magnetic manipulators. The operator, needing minimally invasive access to a specific site via a complex winding pathway will be able to design personalized manipulators and fabricate them on demand. Magnetic control will allow the manipulators to be extremely soft and thin. Controlling the position of multiple anchor points along the length of the manipulator will allow shape forming for tortuous curvilinear trajectories without exerting significant pressure on surrounding tissues. Full-body control will also provide the ability to stiffen part of the manipulator to accomplish specific surgical tasks that need structural rigidity. In this thesis, this vision has been taken and soft, shape forming, magnetic manipulators have been developed. Novel modelling, simulation, optimization and fabrication techniques have been established as well as the introduction and demonstration of the concept of material reinforcement for magnetic actuation. Tentacles down to 2 mm diameter have been produced which are currently capable of semi-autonomous, low contact navigation into tortuous, soft phantoms of the digestive and respiratory anatomy - areas of the body which cannot easily be accessed using traditional minimally invasive methods. Whilst there remain many developments to be made, significant and meaningful progress has been demonstrated here on the journey towards autonomous follow-the-leader navigation. It is hoped that this work and any which develop onwards from it will continue to enable miniaturized magnetic endoluminal navigation and thus contribute to the continued progress of medical diagnostics and treatment.","abstract_has_math":false,"creators":["Lloyd, Peter Robert"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Valdastri, Pietro"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-12","date_published":"2022-12","updated_at":"2026-11-18T23:22:02Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.879530"],"render_values":[{"text":"uk.bl.ethos.879530","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/R045291/1","EP/V009818/1","818045"],"render_values":[{"text":"EP/R045291/1","href":null,"code":true},{"text":"EP/V009818/1","href":null,"code":true},{"text":"818045","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["000000024927071X"],"render_values":[{"text":"0000-0002-4927-071X","href":"https://orcid.org/0000-0002-4927-071X","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/32601/1/PRL_Thesis_30-03-2023.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A32601","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Valdastri, Pietro"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC","ERC"]},{"key":"dc:creator","label":"Author","values":["Lloyd, Peter Robert"]},{"key":"person:identifier.orcid","label":"ORCID","values":["000000024927071X"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-12"]},{"key":"dc:date.issued","label":"Date","values":["2022-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Electronic & Electrical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/32601/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] T. da Veiga, J. H. Chandler, P. Lloyd, G. Pittiglio, N. J. Wilkinson, A. K. Hoshiar, R. A. Harris, and P. Valdastri, “Challenges of continuum robots in clinical context: a review,” Progress in Biomedical Engineering, vol. 2, no. 3, p. 032003, aug 2020. [2] C. Heunis, J. Sikorski, and S. Misra, “Flexible Instruments for Endovascular Interventions: Improved Magnetic Steering, Actuation, and Image-Guided Surgical Instruments,” IEEE Robotics and Automation Magazine, vol. 25, no. 3, pp. 71–82, 2018. [3] G. Pittiglio, P. Lloyd, T. da Veiga, O. Onaizah, C. Pompili, J. Chandler, and P. Valdastri, “Patient-specific magnetic catheters for atraumatic autonomous endoscopy,” Soft Robotics, 2022. [4] J. Burgner-Kahrs, D. C. Rucker, and H. Choset, “Continuum robots for medical applications: A survey,” IEEE Transactions on Robotics, vol. 31, no. 6, pp. 1261–1280, 2015. [5] P. E. Dupont, B. J. Nelson, M. Goldfarb, B. Hannaford, A. Menciassi, M. K. O’Malley, N. Simaan, P. Valdastri, and G.-Z. Yang, “A decade retrospective of medical robotics research from 2010 to 2020,” Science Robotics, vol. 6, no. 60, p. eabi8017, 2021. [Online]. Available: https: //www.science.org/doi/abs/10.1126/scirobotics.abi8017 [6] C. Majidi, “Soft-matter engineering for soft robotics,” Advanced Materials Technologies, vol. 4, no. 2, p. 1800477, 2019. [7] P.-G. de Gennes, “Soft matter (nobel lecture),” Angewandte Chemie International Edition in English, vol. 31, no. 7, pp. 842–845, 1992. [8] N. Kastor, V. Vikas, E. Cohen, and R. D. White, “A definition of soft materials for use in the design of robots.” Soft Robotics, pp. 181–182, Sep 2017. [9] I. Levental, P. C. Georges, and P. A. Janmey, “Soft biological materials and their impact on cell function,” Soft Matter, vol. 3, pp. 299–306, 2007. [Online]. Available: http://dx.doi.org/10.1039/B610522J [10] S. Toggweiler, J. Leipsic, R. K. Binder, M. Freeman, M. Barbanti, R. H. Heijmen, D. A.Wood, and J. G.Webb, “Management of vascular access in transcatheter aortic valve replacement,” JACC: Cardiovascular Interventions, vol. 6, no. 8, pp. 767–776, 2013. [11] J. Edelmann, A. J. Petruska, and B. J. Nelson, “Magnetic control of continuum devices,” The International Journal of Robotics Research, vol. 36, no. 1, pp. 68–85, 2017. [12] S. Jeon, A. K. Hoshiar, K. Kim, S. Lee, E. Kim, S. Lee, J.-y. Kim, B. J. Nelson, H.-J. Cha, B.-J. Yi, and H. Choi, “A Magnetically Controlled Soft Microrobot Steering a Guidewire in a Three-Dimensional Phantom Vascular Network,” Soft Robotics, vol. 6, no. 1, pp. 54–68, oct 2018. [Online]. Available: https://doi.org/10.1089/soro.2018.0019 [13] Y. Kim, G. A. Parada, S. Liu, and X. Zhao, “Ferromagnetic soft continuum robots,” Science Robotics, vol. 4, no. 33, p. eaax7329, 2019. [14] L. B. Kratchman, T. L. Bruns, J. J. Abbott, and R. J. Webster, “Guiding elastic rods with a robot-manipulated magnet for medical applications,” IEEE Transactions on Robotics, vol. 33, no. 1, pp. 227–233, Feb 2017. [15] C. M. Heunis, Y. P. Wotte, J. Sikorski, G. P. Furtado, and S. Misra, “The armm system-autonomous steering of magnetically-actuated catheters: Towards endovascular applications,” IEEE Robotics and automation letters, vol. 5, no. 2, pp. 704–711, 2020. [16] G. Z. Lum, Z. Ye, X. Dong, H. Marvi, O. Erin, W. Hu, and M. Sitti, “Shape-programmable magnetic soft matter,” Proceedings of the National Academy of Sciences, vol. 113, no. 41, pp. E6007 LP – E6015, oct 2016. [Online]. Available: http://www.pnas.org/content/113/41/E6007.abstract [17] M. Richter, V. K. Venkiteswaran, and S. Misra, “Multi-point orientation control of discretely-magnetized continuum manipulators,” IEEE Robotics and Automation Letters, vol. 6, no. 2, pp. 3607–3614, 2021. [18] P. Lloyd, O. Onaizah, G. Pittiglio, D. K. Vithanage, J. H. Chandler, and P. Valdastri, “Magnetic soft continuum robots with braided reinforcement,” IEEE Robotics and Automation Letters, vol. 7, no. 4, pp. 9770–9777, 2022. [19] T. Xu, J. Zhang, M. Salehizadeh, O. Onaizah, and E. Diller, “Millimeter-scale flexible robots with programmable three-dimensional magnetization and motions,” Science Robotics, vol. 4, no. 29, p. eaav4494, 2019. [20] C. Pawashe, S. Floyd, and M. Sitti, “Modeling and experimental characterization of an untethered magnetic micro-robot,” The International Journal of Robotics Research, vol. 28, no. 8, pp. 1077–1094, 2009. [Online]. Available: https: //doi.org/10.1177/0278364909341413 [21] J. C. Norton, P. R. Slawinski, H. S. Lay, J. W. Martin, B. F. Cox, G. Cummins, M. P. Desmulliez, R. E. Clutton, K. L. Obstein, S. Cochran, and P. Valdastri, “Intelligent magnetic manipulation for gastrointestinal ultrasound,” Science Robotics, vol. 4, no. 31, pp. 1–14, 2019. [22] J. W. Martin, B. Scaglioni, J. C. Norton, V. Subramanian, A. Arezzo, K. L. Obstein, and P. Valdastri, “Enabling the future of colonoscopy with intelligent and autonomous magnetic manipulation,” Nature machine intelligence, vol. 2, no. 10, pp. 595–606, 2020. [23] P. Lloyd, A. K. Hoshiar, T. da Veiga, A. Attanasio, N. Marahrens, J. H. Chandler, and P. Valdastri, “A learnt approach for the design of magnetically actuated shape forming soft tentacle robots,” IEEE Robotics and Automation Letters, vol. 5, no. 3, pp. 3937–3944, 2020. [24] P. Lloyd, G. Pittiglio, J. H. Chandler, and P. Valdastri, “Optimal design of soft continuum magnetic robots under follow-the-leader shape forming actuation,” in 2020 International Symposium on Medical Robotics (ISMR), 2020, pp. 111–117. [25] P. Lloyd, Z. Koszowska, M. Di Lecce, O. Onaizah, J. H. Chandler, and P. Valdastri, “Feasibility of fiber reinforcement within magnetically actuated soft continuum robots,” Frontiers in Robotics and AI, vol. 8, 2021. [Online]. Available: https://www.frontiersin.org/article/10.3389/frobt.2021.715662 [26] P. Lloyd, T. L. Thomas, V. K. Venkiteswaran, G. Pittiglio, J. H. Chandler, P. Valdastri, and S. Misra, “A magnetically-actuated coiling soft robot with variable stiffness,” IEEE Robotics and Automation Letters, under review - submitted October 2022. [27] B. J. Nelson, S. Gervasoni, P. W. Chiu, L. Zhang, and A. Zemmar, “Magnetically actuated medical robots: An in vivo perspective,” Proceedings of the IEEE, 2022. [28] H. Tillander, “Magnetic guidance of a catheter with articulated steel tip,” Acta radiologica, vol. 35, no. 1, pp. 62–64, 1951. [29] F. Carpi and C. Pappone, “Stereotaxis niobe magnetic navigation system for endocardial catheter ablation and gastrointestinal capsule endoscopy,” Expert review of medical devices, vol. 6, no. 5, pp. 487–498, 2009. [30] E. Gang, B. L. Nguyen, Y. Shachar, L. Farkas, L. Farkas, B. Marx, D. Johnson, M. Fishbein, C. Gaudio, and S. Kim, “Dynamically shaped magnetic fields initial animal validation of a new remote electrophysiology catheter guidance and control system,” Circulation. Arrhythmia and electrophysiology, vol. 4, pp. 770–7, 06 2011. [31] Y. Chitalia, S. Jeong, J. Bok, V. Nguyen, S. Melkote, J. J. Chern, and J. P. Desai, “Towards the design and development of a pediatric neuroendoscope tool,” in 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2019, pp. 2998–3004. [32] E. Diller, J. Zhuang, G. Zhan Lum, M. R. Edwards, and M. Sitti, “Continuously distributed magnetization profile for millimeter-scale elastomeric undulatory swimming,” Applied Physics Letters, vol. 104, no. 17, p. 174101, 2014. [33] R. Zhao, Y. Kim, S. A. Chester, P. Sharma, and X. Zhao, “Mechanics of hard-magnetic soft materials,” Journal of the Mechanics and Physics of Solids, vol. 124, pp. 244–263, 2019. [Online]. Available: http://www.sciencedirect.com/science/ article/pii/S0022509618307646 [34] V. K. Venkiteswaran, L. F. P. Samaniego, J. Sikorski, and S. Misra, “Bio-inspired terrestrial motion of magnetic soft millirobots,” IEEE Robotics and Automation Letters, vol. 4, no. 2, pp. 1753–1759, 2019. [35] P. E. Dupont, N. Simaan, H. Choset, and C. Rucker, “Continuum robots for medical interventions,” Proceedings of the IEEE, vol. 110, no. 7, pp. 847–870, 2022. [36] B. Siciliano, L. Sciavicco, L. Villani, and G. Oriolo, Robotics: Modelling, Planning and Control. Springer Publishing Company, Incorporated, 2010. [37] M. Pfeiffer, C. Riediger, J. Weitz, and S. Speidel, “Learning soft tissue behavior of organs for surgical navigation with convolutional neural networks,” International Journal of Computer Assisted Radiology and Surgery, vol. 14, no. 7, pp. 1147–1155, 2019. [Online]. Available: https://doi.org/10.1007/s11548-019-01965-7 [38] A. Madani, A. Bakhaty, J. Kim, Y. Mubarak, and M. R. K. Mofrad, “Bridging Finite Element and Machine Learning Modeling: Stress Prediction of Arterial Walls in Atherosclerosis,” Journal of Biomechanical Engineering, vol. 141, no. 8, may 2019. [Online]. Available: https://doi.org/10.1115/1.4043290 [39] T. Da Veiga, J. H. Chandler, G. Pittiglio, P. Lloyd, M. Holdar, O. Onaizah, A. Alazmani, and P. Valdastri, “Material characterization for magnetic soft robots,” in 2021 IEEE 4th International Conference on Soft Robotics (RoboSoft), 2021, pp. 335–342. [40] M. Di Lecce, O. Onaizah, P. Lloyd, J. Chandler, and P. Valdastri, “Evolutionary inverse material identification: Bespoke characterization of soft materials using a metaheuristic algorithm,” Front Robot AI., no. 14;8:790571, Jan 2022. [41] R. J. Roesthuis and S. Misra, “Steering of multisegment continuum manipulators using rigid-link modeling and fbg-based shape sensing,” IEEE transactions on robotics, vol. 32, no. 2, pp. 372–382, 2016. [42] S. Salmanipour and E. Diller, “Eight-Degrees-of-Freedom Remote Actuation of Small Magnetic Mechanisms,” in 2018 IEEE International Conference on Robotics and Automation (ICRA), 2018, pp. 3608–3613. [43] F. Connolly, P. Polygerinos, C. J. Walsh, and K. Bertoldi, “Mechanical programming of soft actuators by varying fiber angle,” Soft Robotics, vol. 2, no. 1, pp. 26–32, 2015."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.879530"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/R045291/1","EP/V009818/1","818045"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/32601/1/PRL_Thesis_30-03-2023.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Currently, we are limited in the tools available to reach deep inside the human body in a non-invasive manner, patients therefore may not have the option to be assessed or treated for life-threatening diseases. The long-term vision of this work is to provide surgeons with the capability to administer care with the aid of soft magnetic manipulators. The operator, needing minimally invasive access to a specific site via a complex winding pathway will be able to design personalized manipulators and fabricate them on demand. Magnetic control will allow the manipulators to be extremely soft and thin. Controlling the position of multiple anchor points along the length of the manipulator will allow shape forming for tortuous curvilinear trajectories without exerting significant pressure on surrounding tissues. Full-body control will also provide the ability to stiffen part of the manipulator to accomplish specific surgical tasks that need structural rigidity. In this thesis, this vision has been taken and soft, shape forming, magnetic manipulators have been developed. Novel modelling, simulation, optimization and fabrication techniques have been established as well as the introduction and demonstration of the concept of material reinforcement for magnetic actuation. Tentacles down to 2 mm diameter have been produced which are currently capable of semi-autonomous, low contact navigation into tortuous, soft phantoms of the digestive and respiratory anatomy - areas of the body which cannot easily be accessed using traditional minimally invasive methods. Whilst there remain many developments to be made, significant and meaningful progress has been demonstrated here on the journey towards autonomous follow-the-leader navigation. It is hoped that this work and any which develop onwards from it will continue to enable miniaturized magnetic endoluminal navigation and thus contribute to the continued progress of medical diagnostics and treatment."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Designing Patient Specific Magnetically Actuated Tentacle Robots for Minimally Invasive Surgery"]}]}],"canonical_facts":{"dc:contributor.advisor":["Valdastri, Pietro"],"dc:contributor.sponsor":["EPSRC","ERC"],"dc:creator":["Lloyd, Peter Robert"],"dc:date":["2022-12"],"dc:date.issued":["2022-12"],"dc:description.abstract":["Currently, we are limited in the tools available to reach deep inside the human body in a non-invasive manner, patients therefore may not have the option to be assessed or treated for life-threatening diseases. The long-term vision of this work is to provide surgeons with the capability to administer care with the aid of soft magnetic manipulators. The operator, needing minimally invasive access to a specific site via a complex winding pathway will be able to design personalized manipulators and fabricate them on demand. Magnetic control will allow the manipulators to be extremely soft and thin. Controlling the position of multiple anchor points along the length of the manipulator will allow shape forming for tortuous curvilinear trajectories without exerting significant pressure on surrounding tissues. Full-body control will also provide the ability to stiffen part of the manipulator to accomplish specific surgical tasks that need structural rigidity. In this thesis, this vision has been taken and soft, shape forming, magnetic manipulators have been developed. Novel modelling, simulation, optimization and fabrication techniques have been established as well as the introduction and demonstration of the concept of material reinforcement for magnetic actuation. Tentacles down to 2 mm diameter have been produced which are currently capable of semi-autonomous, low contact navigation into tortuous, soft phantoms of the digestive and respiratory anatomy - areas of the body which cannot easily be accessed using traditional minimally invasive methods. Whilst there remain many developments to be made, significant and meaningful progress has been demonstrated here on the journey towards autonomous follow-the-leader navigation. It is hoped that this work and any which develop onwards from it will continue to enable miniaturized magnetic endoluminal navigation and thus contribute to the continued progress of medical diagnostics and treatment."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.879530"],"dc:identifier.grantnumber":["EP/R045291/1","EP/V009818/1","818045"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/32601/1/PRL_Thesis_30-03-2023.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Electronic & Electrical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/32601/"],"dc:relation.references":["[1] T. da Veiga, J. H. Chandler, P. Lloyd, G. Pittiglio, N. J. Wilkinson, A. K. Hoshiar, R. A. Harris, and P. Valdastri, “Challenges of continuum robots in clinical context: a review,” Progress in Biomedical Engineering, vol. 2, no. 3, p. 032003, aug 2020. [2] C. Heunis, J. Sikorski, and S. Misra, “Flexible Instruments for Endovascular Interventions: Improved Magnetic Steering, Actuation, and Image-Guided Surgical Instruments,” IEEE Robotics and Automation Magazine, vol. 25, no. 3, pp. 71–82, 2018. [3] G. Pittiglio, P. Lloyd, T. da Veiga, O. Onaizah, C. Pompili, J. Chandler, and P. Valdastri, “Patient-specific magnetic catheters for atraumatic autonomous endoscopy,” Soft Robotics, 2022. [4] J. Burgner-Kahrs, D. C. Rucker, and H. Choset, “Continuum robots for medical applications: A survey,” IEEE Transactions on Robotics, vol. 31, no. 6, pp. 1261–1280, 2015. [5] P. E. Dupont, B. J. Nelson, M. Goldfarb, B. Hannaford, A. Menciassi, M. K. O’Malley, N. Simaan, P. Valdastri, and G.-Z. Yang, “A decade retrospective of medical robotics research from 2010 to 2020,” Science Robotics, vol. 6, no. 60, p. eabi8017, 2021. [Online]. Available: https: //www.science.org/doi/abs/10.1126/scirobotics.abi8017 [6] C. Majidi, “Soft-matter engineering for soft robotics,” Advanced Materials Technologies, vol. 4, no. 2, p. 1800477, 2019. [7] P.-G. de Gennes, “Soft matter (nobel lecture),” Angewandte Chemie International Edition in English, vol. 31, no. 7, pp. 842–845, 1992. [8] N. Kastor, V. Vikas, E. Cohen, and R. D. White, “A definition of soft materials for use in the design of robots.” Soft Robotics, pp. 181–182, Sep 2017. [9] I. Levental, P. C. Georges, and P. A. Janmey, “Soft biological materials and their impact on cell function,” Soft Matter, vol. 3, pp. 299–306, 2007. [Online]. Available: http://dx.doi.org/10.1039/B610522J [10] S. Toggweiler, J. Leipsic, R. K. Binder, M. Freeman, M. Barbanti, R. H. Heijmen, D. A.Wood, and J. G.Webb, “Management of vascular access in transcatheter aortic valve replacement,” JACC: Cardiovascular Interventions, vol. 6, no. 8, pp. 767–776, 2013. [11] J. Edelmann, A. J. Petruska, and B. J. Nelson, “Magnetic control of continuum devices,” The International Journal of Robotics Research, vol. 36, no. 1, pp. 68–85, 2017. [12] S. Jeon, A. K. Hoshiar, K. Kim, S. Lee, E. Kim, S. Lee, J.-y. Kim, B. J. Nelson, H.-J. Cha, B.-J. Yi, and H. Choi, “A Magnetically Controlled Soft Microrobot Steering a Guidewire in a Three-Dimensional Phantom Vascular Network,” Soft Robotics, vol. 6, no. 1, pp. 54–68, oct 2018. [Online]. Available: https://doi.org/10.1089/soro.2018.0019 [13] Y. Kim, G. A. Parada, S. Liu, and X. Zhao, “Ferromagnetic soft continuum robots,” Science Robotics, vol. 4, no. 33, p. eaax7329, 2019. [14] L. B. Kratchman, T. L. Bruns, J. J. Abbott, and R. J. Webster, “Guiding elastic rods with a robot-manipulated magnet for medical applications,” IEEE Transactions on Robotics, vol. 33, no. 1, pp. 227–233, Feb 2017. [15] C. M. Heunis, Y. P. Wotte, J. Sikorski, G. P. Furtado, and S. Misra, “The armm system-autonomous steering of magnetically-actuated catheters: Towards endovascular applications,” IEEE Robotics and automation letters, vol. 5, no. 2, pp. 704–711, 2020. [16] G. Z. Lum, Z. Ye, X. Dong, H. Marvi, O. Erin, W. Hu, and M. Sitti, “Shape-programmable magnetic soft matter,” Proceedings of the National Academy of Sciences, vol. 113, no. 41, pp. E6007 LP – E6015, oct 2016. [Online]. Available: http://www.pnas.org/content/113/41/E6007.abstract [17] M. Richter, V. K. Venkiteswaran, and S. Misra, “Multi-point orientation control of discretely-magnetized continuum manipulators,” IEEE Robotics and Automation Letters, vol. 6, no. 2, pp. 3607–3614, 2021. [18] P. Lloyd, O. Onaizah, G. Pittiglio, D. K. Vithanage, J. H. Chandler, and P. Valdastri, “Magnetic soft continuum robots with braided reinforcement,” IEEE Robotics and Automation Letters, vol. 7, no. 4, pp. 9770–9777, 2022. [19] T. Xu, J. Zhang, M. Salehizadeh, O. Onaizah, and E. Diller, “Millimeter-scale flexible robots with programmable three-dimensional magnetization and motions,” Science Robotics, vol. 4, no. 29, p. eaav4494, 2019. [20] C. Pawashe, S. Floyd, and M. Sitti, “Modeling and experimental characterization of an untethered magnetic micro-robot,” The International Journal of Robotics Research, vol. 28, no. 8, pp. 1077–1094, 2009. [Online]. Available: https: //doi.org/10.1177/0278364909341413 [21] J. C. Norton, P. R. Slawinski, H. S. Lay, J. W. Martin, B. F. Cox, G. Cummins, M. P. Desmulliez, R. E. Clutton, K. L. Obstein, S. Cochran, and P. Valdastri, “Intelligent magnetic manipulation for gastrointestinal ultrasound,” Science Robotics, vol. 4, no. 31, pp. 1–14, 2019. [22] J. W. Martin, B. Scaglioni, J. C. Norton, V. Subramanian, A. Arezzo, K. L. Obstein, and P. Valdastri, “Enabling the future of colonoscopy with intelligent and autonomous magnetic manipulation,” Nature machine intelligence, vol. 2, no. 10, pp. 595–606, 2020. [23] P. Lloyd, A. K. Hoshiar, T. da Veiga, A. Attanasio, N. Marahrens, J. H. Chandler, and P. Valdastri, “A learnt approach for the design of magnetically actuated shape forming soft tentacle robots,” IEEE Robotics and Automation Letters, vol. 5, no. 3, pp. 3937–3944, 2020. [24] P. Lloyd, G. Pittiglio, J. H. Chandler, and P. Valdastri, “Optimal design of soft continuum magnetic robots under follow-the-leader shape forming actuation,” in 2020 International Symposium on Medical Robotics (ISMR), 2020, pp. 111–117. [25] P. Lloyd, Z. Koszowska, M. Di Lecce, O. Onaizah, J. H. Chandler, and P. Valdastri, “Feasibility of fiber reinforcement within magnetically actuated soft continuum robots,” Frontiers in Robotics and AI, vol. 8, 2021. [Online]. Available: https://www.frontiersin.org/article/10.3389/frobt.2021.715662 [26] P. Lloyd, T. L. Thomas, V. K. Venkiteswaran, G. Pittiglio, J. H. Chandler, P. Valdastri, and S. Misra, “A magnetically-actuated coiling soft robot with variable stiffness,” IEEE Robotics and Automation Letters, under review - submitted October 2022. [27] B. J. Nelson, S. Gervasoni, P. W. Chiu, L. Zhang, and A. Zemmar, “Magnetically actuated medical robots: An in vivo perspective,” Proceedings of the IEEE, 2022. [28] H. Tillander, “Magnetic guidance of a catheter with articulated steel tip,” Acta radiologica, vol. 35, no. 1, pp. 62–64, 1951. [29] F. Carpi and C. Pappone, “Stereotaxis niobe magnetic navigation system for endocardial catheter ablation and gastrointestinal capsule endoscopy,” Expert review of medical devices, vol. 6, no. 5, pp. 487–498, 2009. [30] E. Gang, B. L. Nguyen, Y. Shachar, L. Farkas, L. Farkas, B. Marx, D. Johnson, M. Fishbein, C. Gaudio, and S. Kim, “Dynamically shaped magnetic fields initial animal validation of a new remote electrophysiology catheter guidance and control system,” Circulation. Arrhythmia and electrophysiology, vol. 4, pp. 770–7, 06 2011. [31] Y. Chitalia, S. Jeong, J. Bok, V. Nguyen, S. Melkote, J. J. Chern, and J. P. Desai, “Towards the design and development of a pediatric neuroendoscope tool,” in 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2019, pp. 2998–3004. [32] E. Diller, J. Zhuang, G. Zhan Lum, M. R. Edwards, and M. Sitti, “Continuously distributed magnetization profile for millimeter-scale elastomeric undulatory swimming,” Applied Physics Letters, vol. 104, no. 17, p. 174101, 2014. [33] R. Zhao, Y. Kim, S. A. Chester, P. Sharma, and X. Zhao, “Mechanics of hard-magnetic soft materials,” Journal of the Mechanics and Physics of Solids, vol. 124, pp. 244–263, 2019. [Online]. Available: http://www.sciencedirect.com/science/ article/pii/S0022509618307646 [34] V. K. Venkiteswaran, L. F. P. Samaniego, J. Sikorski, and S. Misra, “Bio-inspired terrestrial motion of magnetic soft millirobots,” IEEE Robotics and Automation Letters, vol. 4, no. 2, pp. 1753–1759, 2019. [35] P. E. Dupont, N. Simaan, H. Choset, and C. Rucker, “Continuum robots for medical interventions,” Proceedings of the IEEE, vol. 110, no. 7, pp. 847–870, 2022. [36] B. Siciliano, L. Sciavicco, L. Villani, and G. Oriolo, Robotics: Modelling, Planning and Control. Springer Publishing Company, Incorporated, 2010. [37] M. Pfeiffer, C. Riediger, J. Weitz, and S. Speidel, “Learning soft tissue behavior of organs for surgical navigation with convolutional neural networks,” International Journal of Computer Assisted Radiology and Surgery, vol. 14, no. 7, pp. 1147–1155, 2019. [Online]. Available: https://doi.org/10.1007/s11548-019-01965-7 [38] A. Madani, A. Bakhaty, J. Kim, Y. Mubarak, and M. R. K. Mofrad, “Bridging Finite Element and Machine Learning Modeling: Stress Prediction of Arterial Walls in Atherosclerosis,” Journal of Biomechanical Engineering, vol. 141, no. 8, may 2019. [Online]. Available: https://doi.org/10.1115/1.4043290 [39] T. Da Veiga, J. H. Chandler, G. Pittiglio, P. Lloyd, M. Holdar, O. Onaizah, A. Alazmani, and P. Valdastri, “Material characterization for magnetic soft robots,” in 2021 IEEE 4th International Conference on Soft Robotics (RoboSoft), 2021, pp. 335–342. [40] M. Di Lecce, O. Onaizah, P. Lloyd, J. Chandler, and P. Valdastri, “Evolutionary inverse material identification: Bespoke characterization of soft materials using a metaheuristic algorithm,” Front Robot AI., no. 14;8:790571, Jan 2022. [41] R. J. Roesthuis and S. Misra, “Steering of multisegment continuum manipulators using rigid-link modeling and fbg-based shape sensing,” IEEE transactions on robotics, vol. 32, no. 2, pp. 372–382, 2016. [42] S. Salmanipour and E. Diller, “Eight-Degrees-of-Freedom Remote Actuation of Small Magnetic Mechanisms,” in 2018 IEEE International Conference on Robotics and Automation (ICRA), 2018, pp. 3608–3613. [43] F. Connolly, P. Polygerinos, C. J. Walsh, and K. Bertoldi, “Mechanical programming of soft actuators by varying fiber angle,” Soft Robotics, vol. 2, no. 1, pp. 26–32, 2015."],"dcterms:accessrights":["public"],"dc:title":["Designing Patient Specific Magnetically Actuated Tentacle Robots for Minimally Invasive Surgery"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["000000024927071X"]},"updated_at":"2026-11-18T23:22:02Z"}