{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:33262"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:33262","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Fault modelling and analysis of permanent magnet machines for offshore wind power application","abstract":"Wind energy, as one of the most promising renewable energy sources, has been well developed in the past 30 years. However, the improvement in reliability and availability of wind turbine systems is still an important topic to both academia and industry due to the high operation and maintenance cost. As two of the key components of a wind turbine system, the wind generator and gearbox, have the longest downtime although they are less prone to failure than the power converters and their associated control units. Therefore, it is necessary to study the faults of wind generators and try to reduce their downtime by detecting their faults at an early stage and then implementing effective maintenance. Among all the faults of these wind generators, the winding fault, as the second most frequent fault, has attracted significant interest. It has been reported by the Electrical Apparatus Service Association (EASA) that there are five major winding faults, namely (1) inter-turn (turn-to-turn) short circuit (ITSC), (2) coil-to-coil short circuit, (3) open circuit of one phase, (4) phase-to-phase short circuit, and (5) coil-to-ground short circuit. Amongst all the faults, the ITSC fault, often regarded as one of the root causes of other winding faults, has attracted increasing attention from researchers over the last few years. This thesis will mainly focus on modelling and analysis of permanent magnet machines under ITSC fault for wind power application.","abstract_html":"Wind energy, as one of the most promising renewable energy sources, has been well developed in the past 30 years. However, the improvement in reliability and availability of wind turbine systems is still an important topic to both academia and industry due to the high operation and maintenance cost. As two of the key components of a wind turbine system, the wind generator and gearbox, have the longest downtime although they are less prone to failure than the power converters and their associated control units. Therefore, it is necessary to study the faults of wind generators and try to reduce their downtime by detecting their faults at an early stage and then implementing effective maintenance. Among all the faults of these wind generators, the winding fault, as the second most frequent fault, has attracted significant interest. It has been reported by the Electrical Apparatus Service Association (EASA) that there are five major winding faults, namely (1) inter-turn (turn-to-turn) short circuit (ITSC), (2) coil-to-coil short circuit, (3) open circuit of one phase, (4) phase-to-phase short circuit, and (5) coil-to-ground short circuit. Amongst all the faults, the ITSC fault, often regarded as one of the root causes of other winding faults, has attracted increasing attention from researchers over the last few years. This thesis will mainly focus on modelling and analysis of permanent magnet machines under ITSC fault for wind power application.","abstract_has_math":false,"creators":["Mei, Zeting"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Li, Guang-jin","Zhu, Zi-Qiang"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-05","date_published":"2023-05","updated_at":"2026-11-18T23:23:21Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/R004900/1"],"render_values":[{"text":"EP/R004900/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000178402913"],"render_values":[{"text":"0000-0001-7840-2913","href":"https://orcid.org/0000-0001-7840-2913","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/33262/7/2023-07-12-Thesis-ZTM-v7-final-April.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A33262","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Li, Guang-jin","Zhu, Zi-Qiang"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["UK Engineering and Physical Science Research Council (EPSRC) Partnership, a new partnership in Offshore Wind"]},{"key":"dc:creator","label":"Author","values":["Mei, Zeting"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000178402913"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-05"]},{"key":"dc:date.issued","label":"Date","values":["2023-05"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Electronic and Electrical Engineering (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/33262/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] V. Yaramasu, B. Wu, P. C. Sen, S. Kouro, and M. Narimani, “High-power wind energy conversion systems: State-of-the-art and emerging technologies,” Proc. IEEE, vol. 103, no. 5, pp. 740–788, May 2015. [2] Global Wind Energy Council (GWEC), “Global Wind Report 2022,” 2022. [Online]. Available: https://gwec.net/gwecs-latest-reports/ [3] B. Lu, Y. Li, X. Wu, and Z. Yang, “A review of recent advances in wind turbine condition monitoring and fault diagnosis,” in 2009 IEEE Power Electronics and Machines in Wind Applications, Jun. 2009, pp. 1–7. [4] M. R. Wilkinson, F. Spinato, and P. J. Tavner, “Condition Monitoring of Generators & Other Subassemblies in Wind Turbine Drive Trains,” in 2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, Sep. 2007, pp. 388–392. [5] “The Inside of a Wind Turbine,” Energy.gov. https://www.energy.gov/eere/wind/inside-wind-turbine-0 (accessed Feb. 03, 2019). [6] GE Renewable Energy, “Haliade 150-6MW Offshore Wind Turbine.” https://www.ge.com/renewableenergy/wind-energy/offshore-wind/offshore-turbine-haliade-150-6mw (accessed Apr. 27, 2023). [7] F. Blaabjerg, M. Liserre, and K. Ma, “Power electronics converters for wind turbine systems,” IEEE Trans. Ind. Appl., vol. 48, no. 2, pp. 708–719, Mar. 2012. [8] N. M. A. Freire and J. Marques Cardoso Antonio, “Fault detection and condition monitoring of PMSGs in offshore wind turbines,” Machines, vol. 9, no. 11, p. 260, Oct. 2021. [9] H. Badihi, Y. Zhang, B. Jiang, P. Pillay, and S. Rakheja, “A comprehensive review on signal-based and model-based condition monitoring of wind turbines: fault diagnosis and lifetime prognosis,” Proc. IEEE, vol. 110, no. 6, pp. 754–806, Jun. 2022. [10] V. Yaramasu and B. Wu, Model Predictive Control of Wind Energy Conversion Systems. in IEEE Press Series on Power Engineering. Wiley, 2017. [11] S. Nandi, H. A. Toliyat, and X. Li, “Condition monitoring and fault diagnosis of electrical motors--a review,” IEEE Trans. Energy Convers., vol. 20, no. 4, pp. 719–729, Dec. 2005. [12] A. Bellini, F. Filippetti, C. Tassoni, and G. Capolino, “Advances in diagnostic techniques for induction machines,” IEEE Trans. Ind. Electron., vol. 55, no. 12, pp. 4109–4126, Dec. 2008. [13] A. Gandhi, T. Corrigan, and L. Parsa, “Recent advances in modeling and online detection of stator interturn faults in electrical motors,” IEEE Trans. Ind. Electron., vol. 58, no. 5, pp. 1564–1575, May 2011. [14] R. M. Tallam, S. B. Lee, G. C. Stone, G. B. Kliman, J. Yoo, T. G. Habetler, and R. G. Harley, “A survey of methods for detection of stator-related faults in induction machines,” IEEE Trans. Ind. Appl., vol. 43, no. 4, pp. 920–933, Jul. 2007. [15] A. Siddique, G. S. Yadava, and B. Singh, “A review of stator fault monitoring techniques of induction motors,” IEEE Trans. Energy Convers., vol. 20, no. 1, pp. 106–114, Mar. 2005. [16] S. Grubic, J. M. Aller, B. Lu, and T. G. Habetler, “A survey on testing and monitoring methods for stator insulation systems of low-voltage induction machines focusing on turn insulation problems,” IEEE Trans. Ind. Electron., vol. 55, no. 12, pp. 4127–4136, Dec. 2008. [17] M. Riera-Guasp, J. A. Antonino-Daviu, and G. Capolino, “Advances in electrical machine, power electronic, and drive condition monitoring and fault detection: state of the art,” IEEE Trans. Ind. Electron., vol. 62, no. 3, pp. 1746–1759, Mar. 2015. [18] S. B. Lee, G. C. Stone, J. Antonino-Daviu, K. N. Gyftakis, E. G. Strangas, P. Maussion and C. A. Platero, “Condition monitoring of industrial electric machines: state of the art and future challenges,” IEEE Ind. Electron. Mag., vol. 14, no. 4, pp. 158–167, Dec. 2020. [19] S. Choi, M. S. Haque, M. T. B. Tarek, V. Mulpuri, Y. Duan, S. Das, V. Garg, D. M. Ionel, M. A. Masrur, B. Mirafzal, and H. A. Toliyat, “Fault diagnosis techniques for permanent magnet ac machine and drives-a review of current state of the art,” IEEE Trans. Transport. Electrific., vol. 4, no. 2, pp. 444–463, Jun. 2018. [20] T. Orlowska-Kowalska, M. Wolkiewicz, P. Pietrzak, M. Skowron, P. Ewert, G. Tarchala, M. Krzysztofiak, and C. T. Kowalski, “Fault diagnosis and fault-tolerant control of PMSM drives-state of the art and future challenges,” IEEE Access, vol. 10, pp. 59979–60024, Jun. 2022. [21] A. H. Bonnett and C. Yung, “Increased efficiency versus increased reliability,” IEEE Ind. Appl. Mag., vol. 14, no. 1, pp. 29–36, Jan. 2008. [22] ABB Report, “Motors don’t just fail...do they? A guide to preventing failure.” [Online]. Available: https://new.abb.com/docs/librariesprovider53/about-downloads/ motors_ebook.pdf?sfvrsn=4 [23] B. Li, Y. Tipsuwan, and J. C. Hung, “Neural-network-based motor rolling bearing fault diagnosis,” IEEE Trans. Ind. Electron., vol. 47, no. 5, pp. 1060–1069, Oct. 2000. [24] F. Immovilli, A. Bellini, R. Rubini, and C. Tassoni, “Diagnosis of bearing faults in induction machines by vibration or current signals: a critical comparison,” IEEE Trans. Ind. Appl., vol. 46, no. 4, pp. 1350–1359, Jul. 2010. [25] X. Gong and W. Qiao, “Bearing fault diagnosis for direct-drive wind turbines via current-demodulated signals,” IEEE Trans. Ind. Electron., vol. 60, no. 8, pp. 3419–3428, Aug. 2013. [26] M. D. Prieto, G. Cirrincione, A. G. Espinosa, J. A. Ortega, and H. Henao, “Bearing fault detection by a novel condition-monitoring scheme based on statistical-time features and neural networks,” IEEE Trans. Ind. Electron., vol. 60, no. 8, pp. 3398–3407, Aug. 2013. [27] L. Frosini, C. Harlişca, and L. Szabó, “Induction machine bearing fault detection by means of statistical processing of the stray flux measurement,”IEEE Trans. Ind. Electron., vol. 62, no. 3, pp. 1846–1854, Mar. 2015. [28] F. Cheng, C. Wei, L. Qu, and W. Qiao, “Fault diagnosis of wind turbine gearbox using DFIG stator current analysis,” in 2016 IEEE Energy Conversion Congress and Exposition (ECCE), Sep. 2016, pp. 1–7. [29] G. M. Joksimovic and J. Penman, “The detection of inter-turn short circuits in the stator windings of operating motors,” IEEE Trans. Ind. Electron., vol. 47, no. 5, pp. 1078–1084, Oct. 2000. [30] R. M. Tallam, T. G. Habetler, and R. G. Harley, “Transient model for induction machines with stator winding turn faults,”IEEE Trans. Ind. Appl., vol. 38, no. 3, pp. 632–637, May 2002. [31] C. Gerada, K. J. Bradley, M. Sumner, P. Wheeler, S. Picker, J. Clare, C. Whitley, and G. Towers, “The results do mesh,” IEEE Ind. Appl. Mag., vol. 13, no. 2, pp. 62–72, Mar. 2007. [32] P. Naderi, “Modified magnetic-equivalent-circuit approach for various faults studying in saturable double-cage-induction machines,” IET Electr. Power Appl., vol. 11, no. 7, pp. 1224–1234, Apr. 2017. [33] J. Penman, H. G. Sedding, B. A. Lloyd, and W. T. Fink, “Detection and location of interturn short circuits in the stator windings of operating motors,” IEEE Trans. Energy Convers., vol. 9, no. 4, pp. 652–658, Dec. 1994. [34] A. J. M. Cardoso, S. M. A. Cruz, and D. S. B. Fonseca, “Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park’s vector approach,” IEEE Trans. Energy Convers., vol. 14, no. 3, pp. 595–598, Sep. 1999. [35] G. B. Kliman, R. A. Koegl, J. Stein, R. D. Endicott, and M. W. Madden, “Noninvasive detection of broken rotor bars in operating induction motors,”IEEE Trans. Energy Convers., vol. 3, no. 4, pp. 873–879, Dec. 1988. [36] A. Bellini, F. Filippetti, G. Franceschini, C. Tassoni, and G. B. Kliman, “Quantitative evaluation of induction motor broken bars by means of electrical signature analysis,” IEEE Trans. Ind. Appl., vol. 37, no. 5, pp. 1248–1255, Sep. 2001. [37] M. E. H. Benbouzid and G. B. Kliman, “What stator current processing-based technique to use for induction motor rotor faults diagnosis?,” IEEE Trans. Energy Convers., vol. 18, no. 2, pp. 238–244, Jun. 2003. [38] H. Henao, H. Razik, and G.- Capolino, “Analytical approach of the stator current frequency harmonics computation for detection of induction machine rotor faults,” IEEE Trans. Ind. Appl., vol. 41, no. 3, pp. 801–807, May 2005. [39] J. A. Antonino-Daviu, M. Riera-Guasp, J. R. Folch, and M. P. M. Palomares, “Validation of a new method for the diagnosis of rotor bar failures via wavelet transform in industrial induction machines,” IEEE Trans. Ind. Appl., vol. 42, no. 4, pp. 990–996, Jul. 2006. [40] S. Nandi, R. M. Bharadwaj, and H. A. Toliyat, “Performance analysis of a three-phase induction motor under mixed eccentricity condition,” IEEE Trans. Energy Convers., vol. 17, no. 3, pp. 392–399, Sep. 2002. [41] G. M. Joksimovic, “Dynamic simulation of cage induction machine with air gap eccentricity,” IEE Proc., Electr. Power Appl., vol. 152, no. 4, pp. 803–811, Jul. 2005. [42] X. Li, Q. Wu, and S. Nandi, “Performance Analysis of a Three-Phase Induction Machine With Inclined Static Eccentricity,” IEEE Trans. Ind. Appl., vol. 43, no. 2, pp. 531–541, Mar. 2007. [43] A. Ceban, R. Pusca, and R. Romary, “Study of rotor faults in induction motors using external magnetic field analysis,” IEEE Trans. Ind. Electron., vol. 59, no. 5, pp. 2082–2093, May 2012. [44] P. Naderi and A. Shiri, “Rotor/stator inter-turn short circuit fault detection for saturable wound-rotor induction machine by modified magnetic equivalent circuit approach,” IEEE Trans. Magn., vol. 53, no. 7, pp. 1–13, Jul. 2017. [45] J. Faiz, S. M. M. Moosavi, M. B. Abadi, and S. M. A. Cruz, “Magnetic equivalent circuit modelling of doubly-fed induction generator with assessment of rotor inter-turn short-circuit fault indices,” IET Renew. Power Gener., vol. 10, no. 9, pp. 1431–1440, Oct. 2016. [46] Y. Gritli, L. Zarri, C. Rossi, F. Filippetti, G. Capolino, and D. Casadei, “Advanced diagnosis of electrical faults in wound-rotor induction machines,” IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 4012–4024, Sep. 2013. [47] Y. Gritli, C. Rossi, D. Casadei, F. Filippetti, and G. Capolino, “A diagnostic space vector-based index for rotor electrical fault detection in wound-rotor induction machines under speed transient,” IEEE Trans. Ind. Electron., vol. 64, no. 5, pp. 3892–3902, May 2017. [48] B. M. Ebrahimi and J. Faiz, “Feature extraction for short-circuit fault detection in permanent-magnet synchronous motors using stator-current monitoring,” IEEE Trans. Power Electron., vol. 25, no. 10, pp. 2673–2682, Oct. 2010. [49] L. Romeral, J. C. Urresty, J. R. Ruiz, and A. G. Espinosa, “Modeling of surface-mounted permanent magnet synchronous motors with stator winding interturn faults,” IEEE Trans. Ind. Electron., vol. 58, no. 5, pp. 1576–1585, May 2011. [50] K. Kim, J. Park, J. Hur, and B. Kim, “Comparison of the fault characteristics of IPM-type and SPM-type BLDC motors under inter-turn fault conditions using winding function theory,” IEEE Trans. Ind. Appl., vol. 50, no. 2, pp. 986–994, Mar. 2014. [51] P. Naderi, “Magnetic-equivalent-circuit approach for inter-turn and demagnetisation faults analysis in surface mounted permanent-magnet synchronous machines using pole specific search-coil technique,” IET Electr. Power Appl., vol. 12, no. 7, pp. 916–928, Aug. 2018. [52] M. A. Awadallah, M. M. Morcos, S. Gopalakrishnan, and T. W. Nehl, “Detection of stator short circuits in VSI-fed brushless DC motors using wavelet transform,” IEEE Trans. Energy Convers., vol. 21, no. 1, pp. 1–8, Mar. 2006. [53] B. Vaseghi, B. Nahid-Mobarakeh, N. Takorabet, and F. Meibody-Tabar, “Modeling of non-salient PM synchronous machines under stator winding inter-turn fault condition: dynamic model - FEM model,” in 2007 IEEE Vehicle Power and Propulsion Conference, Sep. 2007, pp. 635–640. [54] J. Farooq, S. Srairi, A. Djerdir, and A. Miraoui, “Use of permeance network method in the demagnetization phenomenon modeling in a permanent magnet motor,” IEEE Trans. Magn., vol. 42, no. 4, pp. 1295–1298, Apr. 2006. [55] B. M. Ebrahimi and J. Faiz, “Demagnetization fault diagnosis in surface mounted permanent magnet synchronous motors,” IEEE Trans. Magn., vol. 49, no. 3, pp. 1185–1192, Mar. 2013. [56] B. M. Ebrahimi and J. Faiz, “Demagnetization fault diagnosis in surface mounted permanent magnet synchronous motors,” IEEE Transactions on Magnetics, vol. 49, no. 3, pp. 1185–1192, Mar. 2013. [57] J. R. R. Ruiz, A. G. Espinosa, L. Romeral, and J. Cusidó, “Demagnetization diagnosis in permanent magnet synchronous motors under non-stationary speed conditions,” Electr. Power Syst. Res., vol. 80, no. 10, pp. 1277–1285, May 2010. [58] J. Hong, S. Park, D. Hyun, T. Kang, S. B. Lee, C. Kral, and A. Haumer, “Detection and classification of rotor demagnetization and eccentricity faults for PM synchronous motors,” IEEE Trans. Ind. Appl., vol. 48, no. 3, pp. 923–932, May 2012. [59] H. Chen, R. Qu, J. Li, and D. Li, “Demagnetization performance of a 7 MW interior permanent magnet wind generator with fractional-slot concentrated windings,” IEEE Trans. Magn., vol. 51, no. 11, pp. 1–4, Nov. 2015. [60] J. Faiz and H. Nejadi-Koti, “Demagnetization fault indexes in permanent magnet synchronous motors—An overview,” IEEE Trans. Magn., vol. 52, no. 4, pp. 1–11, Apr. 2016. [61] G. Choi, Y. Zhang, and T. M. Jahns, “Experimental verification of rotor demagnetization in a fractional-slot concentrated-winding PM synchronous machine under drive fault conditions,” IEEE Trans. Ind. Appl., vol. 53, no. 4, pp. 3467–3475, Jul. 2017. [62] J. Faiz and I. Tabatabaei, “Extension of winding function theory for nonuniform air gap in electric machinery,” IEEE Trans. Magn., vol. 38, no. 6, pp. 3654–3657, Nov. 2002. [63] U. Kim and D. K. Lieu, “Magnetic field calculation in permanent magnet motors with rotor eccentricity: without slotting effect,” IEEE Trans. Magn., vol. 34, no. 4, pp. 2243–2252, Jul. 1998. [64] U. Kim and D. K. Lieu, “Magnetic field calculation in permanent magnet motors with rotor eccentricity: with slotting effect considered,” IEEE Trans. Magn., vol. 34, no. 4, pp. 2253–2266, Jul. 1998. [65] D. G. Dorrell, M. Hsieh, and Y. Guo, “Unbalanced magnet pull in large brushless rare-earth permanent magnet motors with rotor eccentricity,” IEEE Trans. Magn., vol. 45, no. 10, pp. 4586–4589, Oct. 2009. [66] B. M. Ebrahimi, J. Faiz, and M. J. Roshtkhari, “Static-, dynamic-, and mixed-eccentricity fault diagnoses in permanent-magnet synchronous motors,”IEEE Trans. Ind. Electron., vol. 56, no. 11, pp. 4727–4739, Nov. 2009. [67] Y. Li, Q. Lu, Z. Q. Zhu, L. J. Wu, G. J. Li, and D. Wu, “Analytical synthesis of air-gap field distribution in permanent magnet machines with rotor eccentricity by superposition method,” IEEE Trans. Magn., vol. 51, no. 11, pp. 1–4, Nov. 2015. [68] K. Alewine and W. Chen, “A review of electrical winding failures in wind turbine generators,” IEEE Elect. Insul. Mag., vol. 28, no. 4, pp. 8–13, Jul. 2012. [69] A. H. Bonnett and G. C. Soukup, “Cause and analysis of stator and rotor failures in three-phase squirrel-cage induction motors,” IEEE Trans. Ind. Appl., vol. 28, no. 4, pp. 921–937, Jul. 1992. [70] A. H. Bonnett, “Root cause methodology for induction motors: a step-by-step guide to examining failure,” IEEE Ind. Appl. Mag., vol. 18, no. 6, pp. 50–62, Nov. 2012. [71] B. A. Welchko, T. A. Lipo, T. M. Jahns, and S. E. Schulz, “Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations,” IEEE Trans. Power Electron., vol. 19, no. 4, pp. 1108–1116, Jul. 2004. [72] B. A. Welchko, T. M. Jahns, and S. Hiti, “IPM synchronous machine drive response to a single-phase open circuit fault,” IEEE Trans. Power Electron., vol. 17, no. 5, pp. 764–771, Sep. 2002. [73] B. A. Welchko, T. M. Jahns, W. L. Soong, and J. M. Nagashima, “IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults,” IEEE Trans. Energy Convers., vol. 18, no. 2, pp. 291–298, Jun. 2003. [74] G. Choi and T. M. Jahns, “PM synchronous machine drive response to asymmetrical short-circuit faults,” IEEE Trans. Ind. Appl., vol. 52, no. 3, pp. 2176–2185, May 2016. [75] G. Choi and T. M. Jahns, “Investigation of key factors influencing the response of permanent magnet synchronous machines to three-phase symmetrical short-circuit faults,” IEEE Trans. Energy Convers., vol. 31, no. 4, pp. 1488–1497, Dec. 2016. [76] Electrical Apparatus Service Association, Inc, Failures in Three-Phase Stator Windings, 1985. [Online]. Available: https://easa.com/resources/failures-in-three-phase-stator-windings [77] S. B. Lee, J. Yang, K. Younsi, and R. M. Bharadwaj, “An online groundwall and phase-to-phase insulation quality assessment technique for AC-machine stator windings,” IEEE Trans. Ind. Appl., vol. 42, no. 4, pp. 946–957, Jul. 2006. [78] G. C. Stone, I. Culbert, E. A. Boulter, and H. Dhirani, Electrical Insulation for Rotating Machines: Design, Evaluation, Aging, Testing, and Repair, 2nd ed. in IEEE Press Series on Power Engineering. Wiley, 2014. [79] M. Mostafaei and J. Faiz, “An overview of various faults detection methods in synchronous generators,” IET Electr. Power Appl., vol. 15, no. 4, pp. 391–404, Apr. 2021. [80] H. Kim, T. Kong, S. B. Lee, T. Kang, N. Oh, Y. Kim, S. Park, C. Lim, G.C. Stone, “Experience with stator insulation testing and turn/phase insulation failures in the power generation industry,” IEEE Trans. Ind. Appl., vol. 54, no. 3, pp. 2225–2236, May 2018. [81] T. Griffith, A. H. Bonnett, B. Lockley, C. Yung, and C. Nyberg, “Revisions to IEEE standard 1068,” IEEE Ind. Appl. Mag., vol. 17, no. 1, pp. 26–35, Nov. 2010. [82] G. Klempner and I. Kerszenbaum, Handbook of large turbo-generator operation and maintenance, 3rd ed., vol. 91. John Wiley & Sons, 2018. [83] H. A. Toliyat and T. A. Lipo, “Transient analysis of cage induction machines under stator, rotor bar and end ring faults,” IEEE Trans. Energy Convers., vol. 10, no. 2, pp. 241–247, Jun. 1995. [84] P. P. Reichmeider, C. A. Gross, D. Querrey, D. Novosel, and S. Salon, “Internal faults in synchronous machines. I. the machine model,” IEEE Trans. Energy Convers., vol. 15, no. 4, pp. 376–379, Dec. 2000. [85] A. Gandhi, T. Corrigan, and L. Parsa, “Recent advances in modeling and online detection of stator interturn faults in electrical motors,” IEEE Trans. Ind. Electron., vol. 58, no. 5, pp. 1564–1575, May 2011. [86] X. Tu, L. Dessaint, M. E. Kahel, and A. O. Barry, “A new model of synchronous machine internal faults based on winding distribution,” IEEE Trans. Ind. Electron., vol. 53, no. 6, pp. 1818–1828, Dec. 2006. [87] X. Tu, L. Dessaint, N. Fallati, and B. D. Kelper, “Modeling and real-time simulation of internal faults in synchronous generators with parallel-connected windings,” IEEE Trans. Ind. Electron., vol. 54, no. 3, pp. 1400–1409, Jun. 2007. [88] B. Gu, J. Choi, and I. Jung, “Development and analysis of interturn short fault model of PMSMs with series and parallel winding connections,” IEEE Trans. Power Electron., vol. 29, no. 4, pp. 2016–2026, Apr. 2014. [89] H. Qian, H. Guo, and X. Ding, “Modeling and analysis of interturn short fault in permanent magnet synchronous motors with multistrands windings,” IEEE Trans. Power Electron., vol. 31, no. 3, pp. 2496–2509, Mar. 2016. [90] G. Forstner, A. Kugi, and W. Kemmetmüller, “A magnetic equivalent circuit based modeling framework for electric motors applied to a PMSM with winding short circuit,” IEEE Trans. Power Electron., vol. 35, no. 11, pp. 12285–12295, Nov. 2020. [91] C. Gao, K. Lv, J. Si, H. Feng, and Y. Hu, “Research on interturn short-circuit fault indicators for direct-drive permanent magnet synchronous motor,” IEEE J. Emerg. Sel. Top. Power Electron., vol. 10, no. 2, pp. 1902–1914, Apr. 2022. [92] H. W. Derbas, J. M. Williams, A. C. Koenig, and S. D. Pekarek, “A comparison of nodal- and mesh-based magnetic equivalent circuit models,” IEEE Trans. Energy Convers., vol. 24, no. 2, pp. 388–396, Jun. 2009. [93] B. Vaseghi, N. Takorabet, and F. Meibody-Tabar, “Fault analysis and parameter identification of permanent-magnet motors by the finite-element method,”IEEE Trans. Magn., vol. 45, no. 9, pp. 3290–3295, Sep. 2009. [94] V. Ostovic, Dynamics of saturated electric machines. Springer Science & Business Media, 1989. [95] M. Amrhein and P. T. Krein, “3-D magnetic equivalent circuit framework for modeling electromechanical devices,” IEEE Trans. Energy Convers., vol. 24, no. 2, pp. 397–405, Jun. 2009. [96] J. Faiz, H. Nejadi-Koti, and A. H. Exiri, “Inductance-based inter-turn fault detection in permanent magnet synchronous machine using magnetic equivalent circuit model,” Electr. Power Compon. Syst., vol. 45, no. 9, pp. 1016–1030, Jun. 2017. [97] J. Faiz and M. Ghasemi-Bijan, “Estimation of induction machine inductances using three-dimensional magnetic equivalent circuit,” IET Electr. Power Appl., vol. 9, no. 2, pp. 117–127, Feb. 2015. [98] O. A. Mohammed, Z. Liu, S. Liu, and N. Y. Abed, “Internal short circuit fault diagnosis for PM machines using FE-based phase variable model and wavelets analysis,” IEEE Trans. Magn., vol. 43, no. 4, pp. 1729–1732, Apr. 2007. [99] B. Vaseghi, B. Nahid-mobarakh, N. Takorabet, and F. Meibody-Tabar, “Inductance identification and study of PM motor with winding turn short circuit fault,” IEEE Trans. Magn., vol. 47, no. 5, pp. 978–981, May 2011. [100] T. W. Nehl, F. A. Fouad, and N. A. Demerdash, “Determination of saturated values of rotating machinery incremental and apparent inductances by an energy perturbation method,” IEEE Trans. Power App. Syst.*, vol. PAS-101, no. 12, pp. 4441–4451, Dec. 1982. [101] N. A. Demerdash and T. W. Nehl, “Electric machinery parameters and torques by current and energy perturbations from field computations. I. Theory and formulation,” IEEE Trans. Energy Convers., vol. 14, no. 4, pp. 1507–1513, Dec. 1999. [102] N. A. O. Demerdash and J. F. Bangura, “Characterization of induction motors in adjustable-speed drives using a time-stepping coupled finite-element state-space method including experimental validation,” IEEE Trans. Ind. Appl., vol. 35, no. 4, pp. 790–802, Jul/Aug. 1999. [103] J. F. Bangura and N. A. Demerdash, “Simulation of inverter-fed induction motor drives with pulse-width modulation by a time-stepping coupled finite element-flux linkage-based state space model,” IEEE Trans. Energy Convers., vol. 14, no. 3, pp. 518–525, Sep. 1999. [104] N. A. Demerdash and T. W. Nehl, “Electric machinery parameters and torques by current and energy perturbations from field computations. II. Applications and results,” IEEE Trans. Energy Convers., vol. 14, no. 4, pp. 1514–1522, Dec. 1999. [105] D. C. White and H. H. Woodson, Electromechanical Energy Conversion. in The M.I.T. core curriculum program in electrical engineering. Wiley, 1959. [106] P. Krause, O. Wasynczuk, and S. D. Sudhoff, Analysis of Electric Machinery and Drive Systems, 2nd ed. in IEEE Press Series on Power Engineering. Wiley, 2002. [107] S. Umans, A. Fitzgerald, and C. Kingsley, Electric Machinery, 7th ed. McGraw-Hill Higher Education, 2013. [108] G. R. Slemon and A. Straughen, Electric Machines. Addison-Wesley Pub. Co., 1980. [109] X. Wang, Y. Sun, B. Ouyang, W. Wang, Z. Zhu, and D. Howe, “Transient behaviour of salient-pole synchronous machines with internal stator winding faults,” IEE Proc., Electr. Power Appl., vol. 149, no. 2, pp. 143–151, Mar. 2002. [110] M. Dai, A. Keyhani, and T. Sebastian, “Fault analysis of a PM brushless DC motor using finite element method,” IEEE Trans. Energy Convers., vol. 20, no. 1, pp. 1–6, Mar. 2005. [111] L. S. Maraaba, Z. M. Al-Hamouz, and M. A. Abido, “Mathematical modeling, simulation and experimental testing of interior-mount LSPMSM under stator inter-turn fault,” IEEE Trans. Energy Convers., vol. 34, no. 3, pp. 1213–1222, Sep. 2019. [112] D. S. B. Fonseca, C. M. C. Santos, and A. J. M. Cardoso, “Stator faults modeling and diagnostics of line-start permanent magnet synchronous motors,” IEEE Trans. Ind. Appl., vol. 56, no. 3, pp. 2590–2599, Mar. 2020. [113] Z. Sun, J. Wang, D. Howe, and G. Jewell, “Analytical prediction of the short-circuit current in fault-tolerant permanent-magnet machines,” IEEE Trans. Ind. Electron., vol. 55, no. 12, pp. 4210–4217, Dec. 2008. [114] C. Gao, K. Lv, J. Si, P. Su, and C. Gan, “A physical faulty model based on coil sub-element for direct-drive permanent magnet synchronous motor,” IEEE Access, vol. 7, pp. 151307–151319, Oct. 2019. [115] F. Wu, P. Zheng, and T. M. Jahns, “Analytical modeling of interturn short circuit for multiphase fault-tolerant PM machines with fractional slot concentrated windings,” IEEE Trans. Ind. Appl., vol. 53, no. 3, pp. 1994–2006, Jun. 2017. [116] J. A. Haylock, B. C. Mecrow, A. G. Jack, and D. J. Atkinson, “Operation of fault tolerant machines with winding failures,” IEEE Trans. Energy Convers, vol. 14, no. 4, pp. 1490–1495, Dec. 1999. [117] A. J. Mitcham, G. Antonopoulos, and J. J. A. Cullen, “Implications of shorted turn faults in bar wound PM machines,” IEE Proc., Electr. Power Appl., vol. 151, no. 6, pp. 651–657, Nov. 2004. [118] P. Arumugam, T. Hamiti, and C. Gerada, “Modeling of different winding configurations for fault-tolerant permanent magnet machines to restrain interturn short-circuit current,” IEEE Trans. Energy Convers., vol. 27, no. 2, pp. 351–361, Jun. 2012. [119] N. Bianchi, M. Dai Pré, L. Alberti, and E. Fornasiero, Theory and Design of Fractional-Slot PM Machines. in IEEE IAS tutorial corse notes. Cleup, 2007. [120] A. M. EL-Refaie, “Fractional-slot concentrated-windings synchronous permanent magnet machines: Opportunities and challenges,” IEEE Trans. Ind. Electron., vol. 57, no. 1, pp. 107–121, Jan. 2010. [121] A. M. El-Refaie, “Fault-tolerant permanent magnet machines: a review,” IET Electr. Power Appl., vol. 5, no. 1, pp. 59–74, Jan. 2011. [122] W. Zhao, L. Xu, and G. Liu, “Overview of permanent-magnet fault-tolerant machines: Topology and design,” CES Trans. Electr. Mach. Syst., vol. 2, no. 1, pp. 51–64, Mar. 2018. [123] B. Prieto, M. Martínez-Iturralde, L. Fontán, and I. Elosegui, “Fault-tolerant permanent magnet synchronous machine – phase, pole and slot number selection criterion based on inductance calculation,” IET Electr. Power Appl., vol. 9, no. 2, pp. 138–149, Feb. 2015. [124] W. Lee and G. Choi, “A comprehensive review of fault-tolerant ac machine drive topologies: Inverter, control, and electric machine,” in 2021 IEEE 13th international symposium on diagnostics for electrical machines, Power Electronics and Drives (SDEMPED), IEEE, 2021, pp. 269–275. [125] T. Kim, H. Lee, and S. Kwak, “The internal fault analysis of brushless dc motors based on the winding function theory,” IEEE Trans. Magn., vol. 45, no. 5, pp. 2090–2096, May 2009. [126] M. Ojaghi and V. Bahari, “Rotor damping effects in dynamic modeling of three-phase synchronous machines under the stator interturn faults—winding function approach,” IEEE Trans. Ind. Appl., vol. 53, no. 3, pp. 3020–3028, May 2017. [127] Z. T. Mei, G. J. Li, Z. Q. Zhu, R. Clark, A. Thomas, and Z. Azar, “Scaling effect on inter-turn short-circuit of PM machines for wind power application,” in 2021 IEEE International Electric Machines and Drives Conference (IEMDC), 2021, pp. 1–8. [128] B. Ge, S. Xiao, Z. Liu, D. Tao, and X. Sun, “Improved model of synchronous generators internal faults based on circuit-coupled FEM,” IEEE Trans. Energy Convers., vol. 32, no. 3, pp. 876–884, Sep. 2017. [129] M. Zafarani, E. Bostanci, Y. Qi, T. Goktas, and B. Akin, “Interturn short-circuit faults in permanent magnet synchronous machines: An extended review and comprehensive analysis,” IEEE J. Emerg. Sel. Top. Power Electron., vol. 6, no. 4, pp. 2173–2191, Dec. 2018. [130] A. Berzoy, A. A. S. Mohamed, and O. Mohammed, “Impact of inter-turn short-circuit location on induction machines parameters through FE computations,” IEEE Trans. Magn., vol. 53, no. 6, pp. 1–4, Jun. 2017. [131] B. Sen, J. Wang, and P. Lazari, “A high-fidelity computationally efficient transient model of interior permanent-magnet machine with stator turn fault,” IEEE Trans. Ind. Electron., vol. 63, no. 2, pp. 773–783, Feb. 2016. [132] A. Sarikhani and O. A. Mohammed, “Inter-turn fault modeling of a variable speed PM wind generator using physics-based approach,” in 2011 IEEE International Electric Machines Drives Conference (IEMDC), May 2011, pp. 636–641. [133] J. K. Tangudu, T. M. Jahns, A. M. El-Refaie, and Z. Q. Zhu, “Segregation of torque components in fractional-slot concentrated-winding interior PM machines using frozen permeability,” in 2009 IEEE Energy Conversion Congress and Exposition, Sep. 2009, pp. 3814–3821. doi: 10.1109/ECCE.2009.5316039. [134] J. R. Hendershot and T. J. E. Miller, Design of Brushless Permanent-Magnet Machines. Motor Design Books, 2010. [135] T. A. Lipo, Analysis of Synchronous Machines, 2nd ed. CRC Press, 2012. [136] M. B. K. Bouzid, G. Champenois, A. Maalaoui, and S. Tnani, “Efficient simplified physical faulty model of a permanent magnet synchronous generator dedicated to stator fault diagnosis Part I: faulty model conception,” IEEE Trans. Ind. Appl., vol. 53, no. 3, pp. 2752–2761, May 2017. [137] P. J. Davis, Circulant Matrices. in Monographs and textbooks in pure and applied mathematics. Wiley, 1979. [138] J. Huang, M. Kang, J. Yang, H. Jiang, and D. Liu, “Multiphase machine theory and its applications,” in 2008 International Conference on Electrical Machines and Systems, 2008, pp. 1–7. [139] A. G. Yepes, J. A. Riveros, J. Doval-Gandoy, F. Barrero, Ó. Lopez, B. Bogado, M. Jones, and E. Levi, “Parameter identification of multiphase induction machines with distributed windings—Part 1: Sinusoidal excitation methods,” IEEE Trans. Energy Convers., vol. 27, no. 4, Art. no. 4, Dec. 2012. [140] Z. T. Mei, G. J. Li, Z. Q. Zhu, R. Clark, A. Thomas, and Z. Azar, “Modelling and Analysis of Inter-Turn Short-Circuit Fault of PM Machines with Parallel-Connected Coils,” IEEE Trans. Energy Convers., pp. 1–11, 2023. [141] Z. T. Mei, G. J. Li, Z. Q. Zhu, R. Clark, A. Thomas, and Z. Azar, “Scaling effect on inter-turn short-circuit fault of PM machines for wind power application,” IEEE Trans. Ind. Appl., vol. 59, no. 1, pp. 789–800, Feb. 2023. [142] D. K. Kana Padinharu,G. J. Li, Z. Q. Zhu, M. P. Foster, D. A. Stone, A. Griffo, R. Clark, A. Thomas, “Scaling effect on electromagnetic performance of surface-mounted permanent-magnet Vernier machine,” IEEE Trans. Magn., vol. 56, no. 5, pp. 1–15, May 2020. [143] J. Faiz, H. Nejadi-Koti, and Z. Valipour, “Comprehensive review on inter-turn fault indexes in permanent magnet motors,” IET Electr. Power Appl., vol. 11, no. 1, pp. 142–156, Jan. 2017. [144] J. Zhang, W. Zhan, and M. Ehsani, “Diagnosis and fault-tolerant control of permanent magnet synchronous motors with interturn short-circuit fault,” IEEE Trans. Control Syst. Technol., pp. 1–8, 2023. [145] U. Shipurkar, H. Polinder, and J. A. Ferreira, “Modularity in wind türbine generator systems — Opportunities and challenges,” in 2016 18th European Conference on Power Electronics and Applications (EPE’16 ECCE Europe), 2016, pp. 1–10. [146] S. Bomben, G. Mottershead, I. Kerszenbaum, and G. Klempner, Handbook of Large Hydro Generators: Operation and Maintenance. John Wiley & Sons, 2021. [147] Z. Q. Zhu, “A simple method for measuring cogging torque in permanent magnet machines,” in 2009 IEEE Power Energy Society General Meeting, 2009, pp. 1–4."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/R004900/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/33262/7/2023-07-12-Thesis-ZTM-v7-final-April.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Wind energy, as one of the most promising renewable energy sources, has been well developed in the past 30 years. However, the improvement in reliability and availability of wind turbine systems is still an important topic to both academia and industry due to the high operation and maintenance cost. As two of the key components of a wind turbine system, the wind generator and gearbox, have the longest downtime although they are less prone to failure than the power converters and their associated control units. Therefore, it is necessary to study the faults of wind generators and try to reduce their downtime by detecting their faults at an early stage and then implementing effective maintenance. Among all the faults of these wind generators, the winding fault, as the second most frequent fault, has attracted significant interest. It has been reported by the Electrical Apparatus Service Association (EASA) that there are five major winding faults, namely (1) inter-turn (turn-to-turn) short circuit (ITSC), (2) coil-to-coil short circuit, (3) open circuit of one phase, (4) phase-to-phase short circuit, and (5) coil-to-ground short circuit. Amongst all the faults, the ITSC fault, often regarded as one of the root causes of other winding faults, has attracted increasing attention from researchers over the last few years. This thesis will mainly focus on modelling and analysis of permanent magnet machines under ITSC fault for wind power application."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Fault modelling and analysis of permanent magnet machines for offshore wind power application"]}]}],"canonical_facts":{"dc:contributor.advisor":["Li, Guang-jin","Zhu, Zi-Qiang"],"dc:contributor.sponsor":["UK Engineering and Physical Science Research Council (EPSRC) Partnership, a new partnership in Offshore Wind"],"dc:creator":["Mei, Zeting"],"dc:date":["2023-05"],"dc:date.issued":["2023-05"],"dc:description.abstract":["Wind energy, as one of the most promising renewable energy sources, has been well developed in the past 30 years. However, the improvement in reliability and availability of wind turbine systems is still an important topic to both academia and industry due to the high operation and maintenance cost. As two of the key components of a wind turbine system, the wind generator and gearbox, have the longest downtime although they are less prone to failure than the power converters and their associated control units. Therefore, it is necessary to study the faults of wind generators and try to reduce their downtime by detecting their faults at an early stage and then implementing effective maintenance. Among all the faults of these wind generators, the winding fault, as the second most frequent fault, has attracted significant interest. It has been reported by the Electrical Apparatus Service Association (EASA) that there are five major winding faults, namely (1) inter-turn (turn-to-turn) short circuit (ITSC), (2) coil-to-coil short circuit, (3) open circuit of one phase, (4) phase-to-phase short circuit, and (5) coil-to-ground short circuit. Amongst all the faults, the ITSC fault, often regarded as one of the root causes of other winding faults, has attracted increasing attention from researchers over the last few years. This thesis will mainly focus on modelling and analysis of permanent magnet machines under ITSC fault for wind power application."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/R004900/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/33262/7/2023-07-12-Thesis-ZTM-v7-final-April.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Electronic and Electrical Engineering (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/33262/"],"dc:relation.references":["[1] V. Yaramasu, B. Wu, P. C. Sen, S. Kouro, and M. Narimani, “High-power wind energy conversion systems: State-of-the-art and emerging technologies,” Proc. IEEE, vol. 103, no. 5, pp. 740–788, May 2015. [2] Global Wind Energy Council (GWEC), “Global Wind Report 2022,” 2022. [Online]. Available: https://gwec.net/gwecs-latest-reports/ [3] B. Lu, Y. Li, X. Wu, and Z. Yang, “A review of recent advances in wind turbine condition monitoring and fault diagnosis,” in 2009 IEEE Power Electronics and Machines in Wind Applications, Jun. 2009, pp. 1–7. [4] M. R. Wilkinson, F. Spinato, and P. J. Tavner, “Condition Monitoring of Generators & Other Subassemblies in Wind Turbine Drive Trains,” in 2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, Sep. 2007, pp. 388–392. [5] “The Inside of a Wind Turbine,” Energy.gov. https://www.energy.gov/eere/wind/inside-wind-turbine-0 (accessed Feb. 03, 2019). [6] GE Renewable Energy, “Haliade 150-6MW Offshore Wind Turbine.” https://www.ge.com/renewableenergy/wind-energy/offshore-wind/offshore-turbine-haliade-150-6mw (accessed Apr. 27, 2023). [7] F. Blaabjerg, M. Liserre, and K. Ma, “Power electronics converters for wind turbine systems,” IEEE Trans. Ind. Appl., vol. 48, no. 2, pp. 708–719, Mar. 2012. [8] N. M. A. Freire and J. Marques Cardoso Antonio, “Fault detection and condition monitoring of PMSGs in offshore wind turbines,” Machines, vol. 9, no. 11, p. 260, Oct. 2021. [9] H. Badihi, Y. Zhang, B. Jiang, P. Pillay, and S. Rakheja, “A comprehensive review on signal-based and model-based condition monitoring of wind turbines: fault diagnosis and lifetime prognosis,” Proc. IEEE, vol. 110, no. 6, pp. 754–806, Jun. 2022. [10] V. Yaramasu and B. Wu, Model Predictive Control of Wind Energy Conversion Systems. in IEEE Press Series on Power Engineering. Wiley, 2017. [11] S. Nandi, H. A. Toliyat, and X. Li, “Condition monitoring and fault diagnosis of electrical motors--a review,” IEEE Trans. Energy Convers., vol. 20, no. 4, pp. 719–729, Dec. 2005. [12] A. Bellini, F. Filippetti, C. Tassoni, and G. Capolino, “Advances in diagnostic techniques for induction machines,” IEEE Trans. Ind. Electron., vol. 55, no. 12, pp. 4109–4126, Dec. 2008. [13] A. Gandhi, T. Corrigan, and L. Parsa, “Recent advances in modeling and online detection of stator interturn faults in electrical motors,” IEEE Trans. Ind. Electron., vol. 58, no. 5, pp. 1564–1575, May 2011. [14] R. M. Tallam, S. B. Lee, G. C. Stone, G. B. Kliman, J. Yoo, T. G. Habetler, and R. G. Harley, “A survey of methods for detection of stator-related faults in induction machines,” IEEE Trans. Ind. Appl., vol. 43, no. 4, pp. 920–933, Jul. 2007. [15] A. Siddique, G. S. Yadava, and B. Singh, “A review of stator fault monitoring techniques of induction motors,” IEEE Trans. Energy Convers., vol. 20, no. 1, pp. 106–114, Mar. 2005. [16] S. Grubic, J. M. Aller, B. Lu, and T. G. Habetler, “A survey on testing and monitoring methods for stator insulation systems of low-voltage induction machines focusing on turn insulation problems,” IEEE Trans. Ind. Electron., vol. 55, no. 12, pp. 4127–4136, Dec. 2008. [17] M. Riera-Guasp, J. A. Antonino-Daviu, and G. Capolino, “Advances in electrical machine, power electronic, and drive condition monitoring and fault detection: state of the art,” IEEE Trans. Ind. Electron., vol. 62, no. 3, pp. 1746–1759, Mar. 2015. [18] S. B. Lee, G. C. Stone, J. Antonino-Daviu, K. N. Gyftakis, E. G. Strangas, P. Maussion and C. A. Platero, “Condition monitoring of industrial electric machines: state of the art and future challenges,” IEEE Ind. Electron. Mag., vol. 14, no. 4, pp. 158–167, Dec. 2020. [19] S. Choi, M. S. Haque, M. T. B. Tarek, V. Mulpuri, Y. Duan, S. Das, V. Garg, D. M. Ionel, M. A. Masrur, B. Mirafzal, and H. A. Toliyat, “Fault diagnosis techniques for permanent magnet ac machine and drives-a review of current state of the art,” IEEE Trans. Transport. Electrific., vol. 4, no. 2, pp. 444–463, Jun. 2018. [20] T. Orlowska-Kowalska, M. Wolkiewicz, P. Pietrzak, M. Skowron, P. Ewert, G. Tarchala, M. Krzysztofiak, and C. T. Kowalski, “Fault diagnosis and fault-tolerant control of PMSM drives-state of the art and future challenges,” IEEE Access, vol. 10, pp. 59979–60024, Jun. 2022. [21] A. H. Bonnett and C. Yung, “Increased efficiency versus increased reliability,” IEEE Ind. Appl. Mag., vol. 14, no. 1, pp. 29–36, Jan. 2008. [22] ABB Report, “Motors don’t just fail...do they? A guide to preventing failure.” [Online]. Available: https://new.abb.com/docs/librariesprovider53/about-downloads/ motors_ebook.pdf?sfvrsn=4 [23] B. Li, Y. Tipsuwan, and J. C. Hung, “Neural-network-based motor rolling bearing fault diagnosis,” IEEE Trans. Ind. Electron., vol. 47, no. 5, pp. 1060–1069, Oct. 2000. [24] F. Immovilli, A. Bellini, R. Rubini, and C. Tassoni, “Diagnosis of bearing faults in induction machines by vibration or current signals: a critical comparison,” IEEE Trans. Ind. Appl., vol. 46, no. 4, pp. 1350–1359, Jul. 2010. [25] X. Gong and W. Qiao, “Bearing fault diagnosis for direct-drive wind turbines via current-demodulated signals,” IEEE Trans. Ind. Electron., vol. 60, no. 8, pp. 3419–3428, Aug. 2013. [26] M. D. Prieto, G. Cirrincione, A. G. Espinosa, J. A. Ortega, and H. Henao, “Bearing fault detection by a novel condition-monitoring scheme based on statistical-time features and neural networks,” IEEE Trans. Ind. Electron., vol. 60, no. 8, pp. 3398–3407, Aug. 2013. [27] L. Frosini, C. Harlişca, and L. Szabó, “Induction machine bearing fault detection by means of statistical processing of the stray flux measurement,”IEEE Trans. Ind. Electron., vol. 62, no. 3, pp. 1846–1854, Mar. 2015. [28] F. Cheng, C. Wei, L. Qu, and W. Qiao, “Fault diagnosis of wind turbine gearbox using DFIG stator current analysis,” in 2016 IEEE Energy Conversion Congress and Exposition (ECCE), Sep. 2016, pp. 1–7. [29] G. M. Joksimovic and J. Penman, “The detection of inter-turn short circuits in the stator windings of operating motors,” IEEE Trans. Ind. Electron., vol. 47, no. 5, pp. 1078–1084, Oct. 2000. [30] R. M. Tallam, T. G. Habetler, and R. G. Harley, “Transient model for induction machines with stator winding turn faults,”IEEE Trans. Ind. Appl., vol. 38, no. 3, pp. 632–637, May 2002. [31] C. Gerada, K. J. Bradley, M. Sumner, P. Wheeler, S. Picker, J. Clare, C. Whitley, and G. Towers, “The results do mesh,” IEEE Ind. Appl. Mag., vol. 13, no. 2, pp. 62–72, Mar. 2007. [32] P. Naderi, “Modified magnetic-equivalent-circuit approach for various faults studying in saturable double-cage-induction machines,” IET Electr. Power Appl., vol. 11, no. 7, pp. 1224–1234, Apr. 2017. [33] J. Penman, H. G. Sedding, B. A. Lloyd, and W. T. Fink, “Detection and location of interturn short circuits in the stator windings of operating motors,” IEEE Trans. Energy Convers., vol. 9, no. 4, pp. 652–658, Dec. 1994. [34] A. J. M. Cardoso, S. M. A. Cruz, and D. S. B. Fonseca, “Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park’s vector approach,” IEEE Trans. Energy Convers., vol. 14, no. 3, pp. 595–598, Sep. 1999. [35] G. B. Kliman, R. A. Koegl, J. Stein, R. D. Endicott, and M. W. Madden, “Noninvasive detection of broken rotor bars in operating induction motors,”IEEE Trans. Energy Convers., vol. 3, no. 4, pp. 873–879, Dec. 1988. [36] A. Bellini, F. Filippetti, G. Franceschini, C. Tassoni, and G. B. Kliman, “Quantitative evaluation of induction motor broken bars by means of electrical signature analysis,” IEEE Trans. Ind. Appl., vol. 37, no. 5, pp. 1248–1255, Sep. 2001. [37] M. E. H. Benbouzid and G. B. Kliman, “What stator current processing-based technique to use for induction motor rotor faults diagnosis?,” IEEE Trans. Energy Convers., vol. 18, no. 2, pp. 238–244, Jun. 2003. [38] H. Henao, H. Razik, and G.- Capolino, “Analytical approach of the stator current frequency harmonics computation for detection of induction machine rotor faults,” IEEE Trans. Ind. Appl., vol. 41, no. 3, pp. 801–807, May 2005. [39] J. A. Antonino-Daviu, M. Riera-Guasp, J. R. Folch, and M. P. M. Palomares, “Validation of a new method for the diagnosis of rotor bar failures via wavelet transform in industrial induction machines,” IEEE Trans. Ind. Appl., vol. 42, no. 4, pp. 990–996, Jul. 2006. [40] S. Nandi, R. M. Bharadwaj, and H. A. Toliyat, “Performance analysis of a three-phase induction motor under mixed eccentricity condition,” IEEE Trans. Energy Convers., vol. 17, no. 3, pp. 392–399, Sep. 2002. [41] G. M. Joksimovic, “Dynamic simulation of cage induction machine with air gap eccentricity,” IEE Proc., Electr. Power Appl., vol. 152, no. 4, pp. 803–811, Jul. 2005. [42] X. Li, Q. Wu, and S. Nandi, “Performance Analysis of a Three-Phase Induction Machine With Inclined Static Eccentricity,” IEEE Trans. Ind. Appl., vol. 43, no. 2, pp. 531–541, Mar. 2007. [43] A. Ceban, R. Pusca, and R. Romary, “Study of rotor faults in induction motors using external magnetic field analysis,” IEEE Trans. Ind. Electron., vol. 59, no. 5, pp. 2082–2093, May 2012. [44] P. Naderi and A. Shiri, “Rotor/stator inter-turn short circuit fault detection for saturable wound-rotor induction machine by modified magnetic equivalent circuit approach,” IEEE Trans. Magn., vol. 53, no. 7, pp. 1–13, Jul. 2017. [45] J. Faiz, S. M. M. Moosavi, M. B. Abadi, and S. M. A. Cruz, “Magnetic equivalent circuit modelling of doubly-fed induction generator with assessment of rotor inter-turn short-circuit fault indices,” IET Renew. Power Gener., vol. 10, no. 9, pp. 1431–1440, Oct. 2016. [46] Y. Gritli, L. Zarri, C. Rossi, F. Filippetti, G. Capolino, and D. Casadei, “Advanced diagnosis of electrical faults in wound-rotor induction machines,” IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 4012–4024, Sep. 2013. [47] Y. Gritli, C. Rossi, D. Casadei, F. Filippetti, and G. Capolino, “A diagnostic space vector-based index for rotor electrical fault detection in wound-rotor induction machines under speed transient,” IEEE Trans. Ind. Electron., vol. 64, no. 5, pp. 3892–3902, May 2017. [48] B. M. Ebrahimi and J. Faiz, “Feature extraction for short-circuit fault detection in permanent-magnet synchronous motors using stator-current monitoring,” IEEE Trans. Power Electron., vol. 25, no. 10, pp. 2673–2682, Oct. 2010. [49] L. Romeral, J. C. Urresty, J. R. Ruiz, and A. G. Espinosa, “Modeling of surface-mounted permanent magnet synchronous motors with stator winding interturn faults,” IEEE Trans. Ind. Electron., vol. 58, no. 5, pp. 1576–1585, May 2011. [50] K. Kim, J. Park, J. Hur, and B. Kim, “Comparison of the fault characteristics of IPM-type and SPM-type BLDC motors under inter-turn fault conditions using winding function theory,” IEEE Trans. Ind. Appl., vol. 50, no. 2, pp. 986–994, Mar. 2014. [51] P. Naderi, “Magnetic-equivalent-circuit approach for inter-turn and demagnetisation faults analysis in surface mounted permanent-magnet synchronous machines using pole specific search-coil technique,” IET Electr. Power Appl., vol. 12, no. 7, pp. 916–928, Aug. 2018. [52] M. A. Awadallah, M. M. Morcos, S. Gopalakrishnan, and T. W. Nehl, “Detection of stator short circuits in VSI-fed brushless DC motors using wavelet transform,” IEEE Trans. Energy Convers., vol. 21, no. 1, pp. 1–8, Mar. 2006. [53] B. Vaseghi, B. Nahid-Mobarakeh, N. Takorabet, and F. Meibody-Tabar, “Modeling of non-salient PM synchronous machines under stator winding inter-turn fault condition: dynamic model - FEM model,” in 2007 IEEE Vehicle Power and Propulsion Conference, Sep. 2007, pp. 635–640. [54] J. Farooq, S. Srairi, A. Djerdir, and A. Miraoui, “Use of permeance network method in the demagnetization phenomenon modeling in a permanent magnet motor,” IEEE Trans. Magn., vol. 42, no. 4, pp. 1295–1298, Apr. 2006. [55] B. M. Ebrahimi and J. Faiz, “Demagnetization fault diagnosis in surface mounted permanent magnet synchronous motors,” IEEE Trans. Magn., vol. 49, no. 3, pp. 1185–1192, Mar. 2013. [56] B. M. Ebrahimi and J. Faiz, “Demagnetization fault diagnosis in surface mounted permanent magnet synchronous motors,” IEEE Transactions on Magnetics, vol. 49, no. 3, pp. 1185–1192, Mar. 2013. [57] J. R. R. Ruiz, A. G. Espinosa, L. Romeral, and J. Cusidó, “Demagnetization diagnosis in permanent magnet synchronous motors under non-stationary speed conditions,” Electr. Power Syst. Res., vol. 80, no. 10, pp. 1277–1285, May 2010. [58] J. Hong, S. Park, D. Hyun, T. Kang, S. B. Lee, C. Kral, and A. Haumer, “Detection and classification of rotor demagnetization and eccentricity faults for PM synchronous motors,” IEEE Trans. Ind. Appl., vol. 48, no. 3, pp. 923–932, May 2012. [59] H. Chen, R. Qu, J. Li, and D. Li, “Demagnetization performance of a 7 MW interior permanent magnet wind generator with fractional-slot concentrated windings,” IEEE Trans. Magn., vol. 51, no. 11, pp. 1–4, Nov. 2015. [60] J. Faiz and H. Nejadi-Koti, “Demagnetization fault indexes in permanent magnet synchronous motors—An overview,” IEEE Trans. Magn., vol. 52, no. 4, pp. 1–11, Apr. 2016. [61] G. Choi, Y. Zhang, and T. M. Jahns, “Experimental verification of rotor demagnetization in a fractional-slot concentrated-winding PM synchronous machine under drive fault conditions,” IEEE Trans. Ind. Appl., vol. 53, no. 4, pp. 3467–3475, Jul. 2017. [62] J. Faiz and I. Tabatabaei, “Extension of winding function theory for nonuniform air gap in electric machinery,” IEEE Trans. Magn., vol. 38, no. 6, pp. 3654–3657, Nov. 2002. [63] U. Kim and D. K. Lieu, “Magnetic field calculation in permanent magnet motors with rotor eccentricity: without slotting effect,” IEEE Trans. Magn., vol. 34, no. 4, pp. 2243–2252, Jul. 1998. [64] U. Kim and D. K. Lieu, “Magnetic field calculation in permanent magnet motors with rotor eccentricity: with slotting effect considered,” IEEE Trans. Magn., vol. 34, no. 4, pp. 2253–2266, Jul. 1998. [65] D. G. Dorrell, M. Hsieh, and Y. Guo, “Unbalanced magnet pull in large brushless rare-earth permanent magnet motors with rotor eccentricity,” IEEE Trans. Magn., vol. 45, no. 10, pp. 4586–4589, Oct. 2009. [66] B. M. Ebrahimi, J. Faiz, and M. J. Roshtkhari, “Static-, dynamic-, and mixed-eccentricity fault diagnoses in permanent-magnet synchronous motors,”IEEE Trans. Ind. Electron., vol. 56, no. 11, pp. 4727–4739, Nov. 2009. [67] Y. Li, Q. Lu, Z. Q. Zhu, L. J. Wu, G. J. Li, and D. Wu, “Analytical synthesis of air-gap field distribution in permanent magnet machines with rotor eccentricity by superposition method,” IEEE Trans. Magn., vol. 51, no. 11, pp. 1–4, Nov. 2015. [68] K. Alewine and W. Chen, “A review of electrical winding failures in wind turbine generators,” IEEE Elect. Insul. Mag., vol. 28, no. 4, pp. 8–13, Jul. 2012. [69] A. H. Bonnett and G. C. Soukup, “Cause and analysis of stator and rotor failures in three-phase squirrel-cage induction motors,” IEEE Trans. Ind. Appl., vol. 28, no. 4, pp. 921–937, Jul. 1992. [70] A. H. Bonnett, “Root cause methodology for induction motors: a step-by-step guide to examining failure,” IEEE Ind. Appl. Mag., vol. 18, no. 6, pp. 50–62, Nov. 2012. [71] B. A. Welchko, T. A. Lipo, T. M. Jahns, and S. E. Schulz, “Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations,” IEEE Trans. Power Electron., vol. 19, no. 4, pp. 1108–1116, Jul. 2004. [72] B. A. Welchko, T. M. Jahns, and S. Hiti, “IPM synchronous machine drive response to a single-phase open circuit fault,” IEEE Trans. Power Electron., vol. 17, no. 5, pp. 764–771, Sep. 2002. [73] B. A. Welchko, T. M. Jahns, W. L. Soong, and J. M. Nagashima, “IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults,” IEEE Trans. Energy Convers., vol. 18, no. 2, pp. 291–298, Jun. 2003. [74] G. Choi and T. M. Jahns, “PM synchronous machine drive response to asymmetrical short-circuit faults,” IEEE Trans. Ind. Appl., vol. 52, no. 3, pp. 2176–2185, May 2016. [75] G. Choi and T. M. Jahns, “Investigation of key factors influencing the response of permanent magnet synchronous machines to three-phase symmetrical short-circuit faults,” IEEE Trans. Energy Convers., vol. 31, no. 4, pp. 1488–1497, Dec. 2016. [76] Electrical Apparatus Service Association, Inc, Failures in Three-Phase Stator Windings, 1985. [Online]. Available: https://easa.com/resources/failures-in-three-phase-stator-windings [77] S. B. Lee, J. Yang, K. Younsi, and R. M. Bharadwaj, “An online groundwall and phase-to-phase insulation quality assessment technique for AC-machine stator windings,” IEEE Trans. Ind. Appl., vol. 42, no. 4, pp. 946–957, Jul. 2006. [78] G. C. Stone, I. Culbert, E. A. Boulter, and H. Dhirani, Electrical Insulation for Rotating Machines: Design, Evaluation, Aging, Testing, and Repair, 2nd ed. in IEEE Press Series on Power Engineering. Wiley, 2014. [79] M. Mostafaei and J. Faiz, “An overview of various faults detection methods in synchronous generators,” IET Electr. Power Appl., vol. 15, no. 4, pp. 391–404, Apr. 2021. [80] H. Kim, T. Kong, S. B. Lee, T. Kang, N. Oh, Y. Kim, S. Park, C. Lim, G.C. Stone, “Experience with stator insulation testing and turn/phase insulation failures in the power generation industry,” IEEE Trans. Ind. Appl., vol. 54, no. 3, pp. 2225–2236, May 2018. [81] T. Griffith, A. H. Bonnett, B. Lockley, C. Yung, and C. Nyberg, “Revisions to IEEE standard 1068,” IEEE Ind. Appl. Mag., vol. 17, no. 1, pp. 26–35, Nov. 2010. [82] G. Klempner and I. Kerszenbaum, Handbook of large turbo-generator operation and maintenance, 3rd ed., vol. 91. John Wiley & Sons, 2018. [83] H. A. Toliyat and T. A. Lipo, “Transient analysis of cage induction machines under stator, rotor bar and end ring faults,” IEEE Trans. Energy Convers., vol. 10, no. 2, pp. 241–247, Jun. 1995. [84] P. P. Reichmeider, C. A. Gross, D. Querrey, D. Novosel, and S. Salon, “Internal faults in synchronous machines. I. the machine model,” IEEE Trans. Energy Convers., vol. 15, no. 4, pp. 376–379, Dec. 2000. [85] A. Gandhi, T. Corrigan, and L. Parsa, “Recent advances in modeling and online detection of stator interturn faults in electrical motors,” IEEE Trans. Ind. Electron., vol. 58, no. 5, pp. 1564–1575, May 2011. [86] X. Tu, L. Dessaint, M. E. Kahel, and A. O. Barry, “A new model of synchronous machine internal faults based on winding distribution,” IEEE Trans. Ind. Electron., vol. 53, no. 6, pp. 1818–1828, Dec. 2006. [87] X. Tu, L. Dessaint, N. Fallati, and B. D. Kelper, “Modeling and real-time simulation of internal faults in synchronous generators with parallel-connected windings,” IEEE Trans. Ind. Electron., vol. 54, no. 3, pp. 1400–1409, Jun. 2007. [88] B. Gu, J. Choi, and I. Jung, “Development and analysis of interturn short fault model of PMSMs with series and parallel winding connections,” IEEE Trans. Power Electron., vol. 29, no. 4, pp. 2016–2026, Apr. 2014. [89] H. Qian, H. Guo, and X. Ding, “Modeling and analysis of interturn short fault in permanent magnet synchronous motors with multistrands windings,” IEEE Trans. Power Electron., vol. 31, no. 3, pp. 2496–2509, Mar. 2016. [90] G. Forstner, A. Kugi, and W. Kemmetmüller, “A magnetic equivalent circuit based modeling framework for electric motors applied to a PMSM with winding short circuit,” IEEE Trans. Power Electron., vol. 35, no. 11, pp. 12285–12295, Nov. 2020. [91] C. Gao, K. Lv, J. Si, H. Feng, and Y. Hu, “Research on interturn short-circuit fault indicators for direct-drive permanent magnet synchronous motor,” IEEE J. Emerg. Sel. Top. Power Electron., vol. 10, no. 2, pp. 1902–1914, Apr. 2022. [92] H. W. Derbas, J. M. Williams, A. C. Koenig, and S. D. Pekarek, “A comparison of nodal- and mesh-based magnetic equivalent circuit models,” IEEE Trans. Energy Convers., vol. 24, no. 2, pp. 388–396, Jun. 2009. [93] B. Vaseghi, N. Takorabet, and F. Meibody-Tabar, “Fault analysis and parameter identification of permanent-magnet motors by the finite-element method,”IEEE Trans. Magn., vol. 45, no. 9, pp. 3290–3295, Sep. 2009. [94] V. Ostovic, Dynamics of saturated electric machines. Springer Science & Business Media, 1989. [95] M. Amrhein and P. T. Krein, “3-D magnetic equivalent circuit framework for modeling electromechanical devices,” IEEE Trans. Energy Convers., vol. 24, no. 2, pp. 397–405, Jun. 2009. [96] J. Faiz, H. Nejadi-Koti, and A. H. Exiri, “Inductance-based inter-turn fault detection in permanent magnet synchronous machine using magnetic equivalent circuit model,” Electr. Power Compon. Syst., vol. 45, no. 9, pp. 1016–1030, Jun. 2017. [97] J. Faiz and M. Ghasemi-Bijan, “Estimation of induction machine inductances using three-dimensional magnetic equivalent circuit,” IET Electr. Power Appl., vol. 9, no. 2, pp. 117–127, Feb. 2015. [98] O. A. Mohammed, Z. Liu, S. Liu, and N. Y. Abed, “Internal short circuit fault diagnosis for PM machines using FE-based phase variable model and wavelets analysis,” IEEE Trans. Magn., vol. 43, no. 4, pp. 1729–1732, Apr. 2007. [99] B. Vaseghi, B. Nahid-mobarakh, N. Takorabet, and F. Meibody-Tabar, “Inductance identification and study of PM motor with winding turn short circuit fault,” IEEE Trans. Magn., vol. 47, no. 5, pp. 978–981, May 2011. [100] T. W. Nehl, F. A. Fouad, and N. A. Demerdash, “Determination of saturated values of rotating machinery incremental and apparent inductances by an energy perturbation method,” IEEE Trans. Power App. Syst.*, vol. PAS-101, no. 12, pp. 4441–4451, Dec. 1982. [101] N. A. Demerdash and T. W. Nehl, “Electric machinery parameters and torques by current and energy perturbations from field computations. I. Theory and formulation,” IEEE Trans. Energy Convers., vol. 14, no. 4, pp. 1507–1513, Dec. 1999. [102] N. A. O. Demerdash and J. F. Bangura, “Characterization of induction motors in adjustable-speed drives using a time-stepping coupled finite-element state-space method including experimental validation,” IEEE Trans. Ind. Appl., vol. 35, no. 4, pp. 790–802, Jul/Aug. 1999. [103] J. F. Bangura and N. A. Demerdash, “Simulation of inverter-fed induction motor drives with pulse-width modulation by a time-stepping coupled finite element-flux linkage-based state space model,” IEEE Trans. Energy Convers., vol. 14, no. 3, pp. 518–525, Sep. 1999. [104] N. A. Demerdash and T. W. Nehl, “Electric machinery parameters and torques by current and energy perturbations from field computations. II. Applications and results,” IEEE Trans. Energy Convers., vol. 14, no. 4, pp. 1514–1522, Dec. 1999. [105] D. C. White and H. H. Woodson, Electromechanical Energy Conversion. in The M.I.T. core curriculum program in electrical engineering. Wiley, 1959. [106] P. Krause, O. Wasynczuk, and S. D. Sudhoff, Analysis of Electric Machinery and Drive Systems, 2nd ed. in IEEE Press Series on Power Engineering. Wiley, 2002. [107] S. Umans, A. Fitzgerald, and C. Kingsley, Electric Machinery, 7th ed. McGraw-Hill Higher Education, 2013. [108] G. R. Slemon and A. Straughen, Electric Machines. Addison-Wesley Pub. Co., 1980. [109] X. Wang, Y. Sun, B. Ouyang, W. Wang, Z. Zhu, and D. Howe, “Transient behaviour of salient-pole synchronous machines with internal stator winding faults,” IEE Proc., Electr. Power Appl., vol. 149, no. 2, pp. 143–151, Mar. 2002. [110] M. Dai, A. Keyhani, and T. Sebastian, “Fault analysis of a PM brushless DC motor using finite element method,” IEEE Trans. Energy Convers., vol. 20, no. 1, pp. 1–6, Mar. 2005. [111] L. S. Maraaba, Z. M. Al-Hamouz, and M. A. Abido, “Mathematical modeling, simulation and experimental testing of interior-mount LSPMSM under stator inter-turn fault,” IEEE Trans. Energy Convers., vol. 34, no. 3, pp. 1213–1222, Sep. 2019. [112] D. S. B. Fonseca, C. M. C. Santos, and A. J. M. Cardoso, “Stator faults modeling and diagnostics of line-start permanent magnet synchronous motors,” IEEE Trans. Ind. Appl., vol. 56, no. 3, pp. 2590–2599, Mar. 2020. [113] Z. Sun, J. Wang, D. Howe, and G. Jewell, “Analytical prediction of the short-circuit current in fault-tolerant permanent-magnet machines,” IEEE Trans. Ind. Electron., vol. 55, no. 12, pp. 4210–4217, Dec. 2008. [114] C. Gao, K. Lv, J. Si, P. Su, and C. Gan, “A physical faulty model based on coil sub-element for direct-drive permanent magnet synchronous motor,” IEEE Access, vol. 7, pp. 151307–151319, Oct. 2019. [115] F. Wu, P. Zheng, and T. M. Jahns, “Analytical modeling of interturn short circuit for multiphase fault-tolerant PM machines with fractional slot concentrated windings,” IEEE Trans. Ind. Appl., vol. 53, no. 3, pp. 1994–2006, Jun. 2017. [116] J. A. Haylock, B. C. Mecrow, A. G. Jack, and D. J. Atkinson, “Operation of fault tolerant machines with winding failures,” IEEE Trans. Energy Convers, vol. 14, no. 4, pp. 1490–1495, Dec. 1999. [117] A. J. Mitcham, G. Antonopoulos, and J. J. A. Cullen, “Implications of shorted turn faults in bar wound PM machines,” IEE Proc., Electr. Power Appl., vol. 151, no. 6, pp. 651–657, Nov. 2004. [118] P. Arumugam, T. Hamiti, and C. Gerada, “Modeling of different winding configurations for fault-tolerant permanent magnet machines to restrain interturn short-circuit current,” IEEE Trans. Energy Convers., vol. 27, no. 2, pp. 351–361, Jun. 2012. [119] N. Bianchi, M. Dai Pré, L. Alberti, and E. Fornasiero, Theory and Design of Fractional-Slot PM Machines. in IEEE IAS tutorial corse notes. Cleup, 2007. [120] A. M. EL-Refaie, “Fractional-slot concentrated-windings synchronous permanent magnet machines: Opportunities and challenges,” IEEE Trans. Ind. Electron., vol. 57, no. 1, pp. 107–121, Jan. 2010. [121] A. M. El-Refaie, “Fault-tolerant permanent magnet machines: a review,” IET Electr. Power Appl., vol. 5, no. 1, pp. 59–74, Jan. 2011. [122] W. Zhao, L. Xu, and G. Liu, “Overview of permanent-magnet fault-tolerant machines: Topology and design,” CES Trans. Electr. Mach. Syst., vol. 2, no. 1, pp. 51–64, Mar. 2018. [123] B. Prieto, M. Martínez-Iturralde, L. Fontán, and I. Elosegui, “Fault-tolerant permanent magnet synchronous machine – phase, pole and slot number selection criterion based on inductance calculation,” IET Electr. Power Appl., vol. 9, no. 2, pp. 138–149, Feb. 2015. [124] W. Lee and G. Choi, “A comprehensive review of fault-tolerant ac machine drive topologies: Inverter, control, and electric machine,” in 2021 IEEE 13th international symposium on diagnostics for electrical machines, Power Electronics and Drives (SDEMPED), IEEE, 2021, pp. 269–275. [125] T. Kim, H. Lee, and S. Kwak, “The internal fault analysis of brushless dc motors based on the winding function theory,” IEEE Trans. Magn., vol. 45, no. 5, pp. 2090–2096, May 2009. [126] M. Ojaghi and V. Bahari, “Rotor damping effects in dynamic modeling of three-phase synchronous machines under the stator interturn faults—winding function approach,” IEEE Trans. Ind. Appl., vol. 53, no. 3, pp. 3020–3028, May 2017. [127] Z. T. Mei, G. J. Li, Z. Q. Zhu, R. Clark, A. Thomas, and Z. Azar, “Scaling effect on inter-turn short-circuit of PM machines for wind power application,” in 2021 IEEE International Electric Machines and Drives Conference (IEMDC), 2021, pp. 1–8. [128] B. Ge, S. Xiao, Z. Liu, D. Tao, and X. Sun, “Improved model of synchronous generators internal faults based on circuit-coupled FEM,” IEEE Trans. Energy Convers., vol. 32, no. 3, pp. 876–884, Sep. 2017. [129] M. Zafarani, E. Bostanci, Y. Qi, T. Goktas, and B. Akin, “Interturn short-circuit faults in permanent magnet synchronous machines: An extended review and comprehensive analysis,” IEEE J. Emerg. Sel. Top. Power Electron., vol. 6, no. 4, pp. 2173–2191, Dec. 2018. [130] A. Berzoy, A. A. S. Mohamed, and O. Mohammed, “Impact of inter-turn short-circuit location on induction machines parameters through FE computations,” IEEE Trans. Magn., vol. 53, no. 6, pp. 1–4, Jun. 2017. [131] B. Sen, J. Wang, and P. Lazari, “A high-fidelity computationally efficient transient model of interior permanent-magnet machine with stator turn fault,” IEEE Trans. Ind. Electron., vol. 63, no. 2, pp. 773–783, Feb. 2016. [132] A. Sarikhani and O. A. Mohammed, “Inter-turn fault modeling of a variable speed PM wind generator using physics-based approach,” in 2011 IEEE International Electric Machines Drives Conference (IEMDC), May 2011, pp. 636–641. [133] J. K. Tangudu, T. M. Jahns, A. M. El-Refaie, and Z. Q. Zhu, “Segregation of torque components in fractional-slot concentrated-winding interior PM machines using frozen permeability,” in 2009 IEEE Energy Conversion Congress and Exposition, Sep. 2009, pp. 3814–3821. doi: 10.1109/ECCE.2009.5316039. [134] J. R. Hendershot and T. J. E. Miller, Design of Brushless Permanent-Magnet Machines. Motor Design Books, 2010. [135] T. A. Lipo, Analysis of Synchronous Machines, 2nd ed. CRC Press, 2012. [136] M. B. K. Bouzid, G. Champenois, A. Maalaoui, and S. Tnani, “Efficient simplified physical faulty model of a permanent magnet synchronous generator dedicated to stator fault diagnosis Part I: faulty model conception,” IEEE Trans. Ind. Appl., vol. 53, no. 3, pp. 2752–2761, May 2017. [137] P. J. Davis, Circulant Matrices. in Monographs and textbooks in pure and applied mathematics. Wiley, 1979. [138] J. Huang, M. Kang, J. Yang, H. Jiang, and D. Liu, “Multiphase machine theory and its applications,” in 2008 International Conference on Electrical Machines and Systems, 2008, pp. 1–7. [139] A. G. Yepes, J. A. Riveros, J. Doval-Gandoy, F. Barrero, Ó. Lopez, B. Bogado, M. Jones, and E. Levi, “Parameter identification of multiphase induction machines with distributed windings—Part 1: Sinusoidal excitation methods,” IEEE Trans. Energy Convers., vol. 27, no. 4, Art. no. 4, Dec. 2012. [140] Z. T. Mei, G. J. Li, Z. Q. Zhu, R. Clark, A. Thomas, and Z. Azar, “Modelling and Analysis of Inter-Turn Short-Circuit Fault of PM Machines with Parallel-Connected Coils,” IEEE Trans. Energy Convers., pp. 1–11, 2023. [141] Z. T. Mei, G. J. Li, Z. Q. Zhu, R. Clark, A. Thomas, and Z. Azar, “Scaling effect on inter-turn short-circuit fault of PM machines for wind power application,” IEEE Trans. Ind. Appl., vol. 59, no. 1, pp. 789–800, Feb. 2023. [142] D. K. Kana Padinharu,G. J. Li, Z. Q. Zhu, M. P. Foster, D. A. Stone, A. Griffo, R. Clark, A. Thomas, “Scaling effect on electromagnetic performance of surface-mounted permanent-magnet Vernier machine,” IEEE Trans. Magn., vol. 56, no. 5, pp. 1–15, May 2020. [143] J. Faiz, H. Nejadi-Koti, and Z. Valipour, “Comprehensive review on inter-turn fault indexes in permanent magnet motors,” IET Electr. Power Appl., vol. 11, no. 1, pp. 142–156, Jan. 2017. [144] J. Zhang, W. Zhan, and M. Ehsani, “Diagnosis and fault-tolerant control of permanent magnet synchronous motors with interturn short-circuit fault,” IEEE Trans. Control Syst. Technol., pp. 1–8, 2023. [145] U. Shipurkar, H. Polinder, and J. A. Ferreira, “Modularity in wind türbine generator systems — Opportunities and challenges,” in 2016 18th European Conference on Power Electronics and Applications (EPE’16 ECCE Europe), 2016, pp. 1–10. [146] S. Bomben, G. Mottershead, I. Kerszenbaum, and G. Klempner, Handbook of Large Hydro Generators: Operation and Maintenance. John Wiley & Sons, 2021. [147] Z. Q. Zhu, “A simple method for measuring cogging torque in permanent magnet machines,” in 2009 IEEE Power Energy Society General Meeting, 2009, pp. 1–4."],"dcterms:accessrights":["public"],"dc:title":["Fault modelling and analysis of permanent magnet machines for offshore wind power application"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000178402913"]},"updated_at":"2026-11-18T23:23:21Z"}