{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:33848"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:33848","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Accuracy of a New Method To Combine Digital Impressions With CBCT Scans Of The Edentulous Mandible","abstract":"Background and Aims: The treatment of edentulous arches with dental implants offers significant benefits over traditional removable prosthetics. However, current implant placement methods, whether freehand or guided, present challenges in terms of accuracy, invasiveness, and postoperative discomfort. The primary aim of this thesis was to address the concern of placement inaccuracy in fully edentulous patients and introduce a more precise method. Materials and Methods: A novel approach, the \"Fixed Edentulous Implant Guide\" (FEIG), is introduced. Unlike conventional tooth-based guides, the FEIG employs three two-part screws to aid matching of reference points to precisely align digital impressions with CBCT scans during virtual planning. This research explored the method's efficacy through in vitro studies and comprehensive literature reviews along with a novel approach to the calculation of the implant position used in the final study. Results: The findings of both the preliminary and final studies show that the novel method presented in this thesis is more accurate than both existing methods of edentulous guided surgery (mucosal borne and bone guides) and dentate guided implant surgery. Through statistical analysis with an independent samples t-test, the final study revealed that the significance is less than than 0.05 for each comparison between the novel FEIG method and the conventional mucosal borne edentulous guided surgery (p<0.001), and a statistically significant difference between the two methods is concluded. The evidence suggests that this approach is both safe and precise, especially when referencing the model to the CBCT scan. Conclusions: The final objective of the thesis was to examine whether it is both safe and accurate to place implants with flapless surgery with this new method that references the model to the CBCT scan. The study findings suggest that this statement can be upheld, and given the accuracy in terms of trueness and precision, it is concluded that the novel method provides an accurate method to place implants in an edentulous arch. Furthermore, as guided implant surgery can often mean that bone can be utilised in an angular or unconventional approach to avoid grafting, using this method may mean that patients with a medical contraindication to conventional flapped surgery may also benefit from full arch rehabilitation.","abstract_html":"Background and Aims: The treatment of edentulous arches with dental implants offers significant benefits over traditional removable prosthetics. However, current implant placement methods, whether freehand or guided, present challenges in terms of accuracy, invasiveness, and postoperative discomfort. The primary aim of this thesis was to address the concern of placement inaccuracy in fully edentulous patients and introduce a more precise method. Materials and Methods: A novel approach, the &quot;Fixed Edentulous Implant Guide&quot; (FEIG), is introduced. Unlike conventional tooth-based guides, the FEIG employs three two-part screws to aid matching of reference points to precisely align digital impressions with CBCT scans during virtual planning. This research explored the method&#x27;s efficacy through in vitro studies and comprehensive literature reviews along with a novel approach to the calculation of the implant position used in the final study. Results: The findings of both the preliminary and final studies show that the novel method presented in this thesis is more accurate than both existing methods of edentulous guided surgery (mucosal borne and bone guides) and dentate guided implant surgery. Through statistical analysis with an independent samples t-test, the final study revealed that the significance is less than than 0.05 for each comparison between the novel FEIG method and the conventional mucosal borne edentulous guided surgery (p&lt;0.001), and a statistically significant difference between the two methods is concluded. The evidence suggests that this approach is both safe and precise, especially when referencing the model to the CBCT scan. Conclusions: The final objective of the thesis was to examine whether it is both safe and accurate to place implants with flapless surgery with this new method that references the model to the CBCT scan. The study findings suggest that this statement can be upheld, and given the accuracy in terms of trueness and precision, it is concluded that the novel method provides an accurate method to place implants in an edentulous arch. Furthermore, as guided implant surgery can often mean that bone can be utilised in an angular or unconventional approach to avoid grafting, using this method may mean that patients with a medical contraindication to conventional flapped surgery may also benefit from full arch rehabilitation.","abstract_has_math":false,"creators":["Nulty, Adam Brian"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Hyde, Paul","Keeling, Andrew","Wood, David"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-08","date_published":"2023-08","updated_at":"2026-11-18T23:24:33Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000233297782"],"render_values":[{"text":"0000-0002-3329-7782","href":"https://orcid.org/0000-0002-3329-7782","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/33848/1/Adam%20Nulty%20PhD%20Thesis.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A33848","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hyde, Paul","Keeling, Andrew","Wood, David"]},{"key":"dc:creator","label":"Author","values":["Nulty, Adam Brian"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000233297782"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-08"]},{"key":"dc:date.issued","label":"Date","values":["2023-08"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Fixed and Removable Prosthodontics (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/33848/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Abdulmohsen, B., Parker, S., Braden, M. and Patel, M.P. 2016. A study to investigate and compare the physicomechanical properties of experimental and commercial temporary crown and bridge materials. Dental Materials. 32, pp.200-210. Abduo, J. 2019. Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses. The Journal of Advanced Prosthodontics. 11, pp.138-146. Akyalcin, S., Cozad, B.E., English, J.D., Colville, C.D. and Laman, S. 2013. Diagnostic accuracy of impression-free digital models. American Journal of Orthodontics and Dentofacial Orthopedics. 144, pp.916-922. Al Mortadi, N., Jones, Q., Eggbeer, D., Lewis, J. and Williams, R.J. 2015. Fabrication of a resin appliance with alloy components using digital technology without an analog impression. American Journal of Orthodontics and Dentofacial Orthopedics. 148, pp.862-867. Al-Imam, H., Gram, M., Benetti, A.R. and Gotfredsen, K. 2018. Accuracy of stereolithography additive casts used in a digital workflow. The Journal of Prosthetic Dentistry. 119, pp.580-585. Alharbi, N., Osman, R. and Wismeijer, D. 2016a. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations. The Journal of Prosthetic Dentistry. 115, pp.760-767. Alharbi, N., Osman, R. and Wismeijer, D. 2016b. Factors Influencing the Dimensional Accuracy of 3D-Printed Full-Coverage Dental Restorations Using Stereolithography Technology. The International Journal of Prosthodontics. 29, pp.503-510. Alharbi, N., van de Veen, A.J., Wismeijer, D. and Osman, R.B. 2018. Build angle and its influence on the flexure strength of stereolithography printed hybrid resin material. An in vitro study and a fractographic analysis. Materials Technology. 34, pp.12-17. Allen, P.F., Thomason, J.M., Jepson, N.J., Nohl, F., Smith, D.G. and Ellis, J. 2006a. A randomized controlled trial of implant-retained mandibular overdentures. J Dent Res. 85, pp.547-51. Allen, P.F., Thomason, J.M., Jepson, N.J.A., Nohl, F., Smith, D.G. and Ellis, J. 2006b. A Randomized Controlled Trial of Implant-retained Mandibular Overdentures. Journal of Dental Research. 85, pp.547-551. Alp, G., Murat, S. and Yilmaz, B. 2018. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers. Journal of Prosthodontics. 28, e491-e495. Amin, S., Weber, H.P., Finkelman, M., El Rafie, K., Kudara, Y. and Papaspyridakos, P. 2016. Digital vs. conventional full-arch implant impressions: a comparative study. Clinical Oral Implants Research. 28, pp.1360-1367. Andonović, V. 2010. Growing rapid prototyping as a technology in dental medicine. Mechanical Engineering Scientific Journal. 29, pp.31-39. Andriessen, F.S., Rijkens, D.R., van der Meer, W.J. and Wismeijer, D.W. 2014. Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study. The Journal of Prosthetic Dentistry. 111, pp.186-194. Anusavice, K.J., Phillips, R.W., Shen, C., and Rawls, H.R. 2013. Phillips' science of dental materials. Arisan, V., Karabuda, Z.C. and Ozdemir, T. 2010. Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. J Periodontol. 81, pp.43-51. Asiga. Available: https://www.asiga.com/products/materials/ [Accessed May 9, 2019]. Astudillo-Rubio, D., Delgado-Gaete, A., Bellot-Arcís, C., Montiel-Company, J.M., Pascual-Moscardó, A. and Almerich-Silla, J.M. 2018. Mechanical properties of provisional dental materials: A systematic review and meta-analysis. PloS one. 13, e0193162-e0193162. Atieh, M.A., Ibrahim, H.M. and Atieh, A.H. 2010. Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis. J Periodontol. 81, pp.1350-66. Atieh, M.A., Ritter, A.V., Ko, C.-C. and Duqum, I. 2017. Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance. The Journal of prosthetic dentistry. 118, pp.400-405. Atwood, D.A., 1971. Reduction of residual ridges: a major oral disease entity. J Prosthet Dent. Sep;26(3) pp. 266-79. Azari, A. and Nikzad, S. 2009. The evolution of rapid prototyping in dentistry: a review. Rapid Prototyping Journal. 15, pp.216-225. Bajraktarova-Valjakova, E., Korunoska-Stevkovska, V., Kapusevska, B., Gigovski, N., Bajraktarova-Misevska, C. and Grozdanov, A. 2018. Contemporary Dental Ceramic Materials, A Review: Chemical Composition, Physical and Mechanical Properties, Indications for Use. Open access Macedonian journal of medical sciences. 6, pp.1742-1755. Balkenhol, M., Köhler, H., Orbach, K. and Wöstmann, B. 2009. Fracture toughness of cross-linked and non-cross-linked temporary crown and fixed partial denture materials. Dental Materials. 25, pp.917-928. Basker, R.M., Davenport J.C., Tomlin, H.R. 1976. Prosthetic Treatment of the Edentulous Patient. MacMillan, London. Becker K, Schmücker U, Schwarz F, Drescher D. 2018. Accuracy and eligibility of CBCT to digitize dental plaster casts. Clin Oral Investig. 22(4), pp.1817-1823. doi: 10.1007/s00784-017-2277-x. Epub 2017 Dec 2. PMID: 29196949. Becker, K., Wilmes, B., Grandjean, C. and Drescher, D. 2018. Impact of manual control point selection accuracy on automated surface matching of digital dental models. Clin Oral Investig. 22, pp.801-810. Bego. 2020. Bego Resin. [Online]. [Accessed 2 Feb 2020]. Available from: https://www.bego.com/3d-printing/materials/ Behneke, A., Burwinkel, M. and Behneke, N. 2012. Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement. Clin Oral Implants Res. 23, pp.416-23. Behneke, A., Burwinkel, M., D’Hoedt, B. and Behneke, N. 2009. Clinical assessment of the reliability of a computer-aided implant planning concept using laboratory-fabricated templates based on cone beam computed tomography. Zeitschrift fu ̈r Zahna ̈rztliche Implantologie. 25, pp.339-352. Bhargav, A., Sanjairaj, V., Rosa, V., Feng, L.W. and Fuh YH, J. 2017. Applications of additive manufacturing in dentistry: A review. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 106, pp.2058-2064. Bhattacharjee, N., Urrios, A., Kang, S. and Folch, A. 2016. The upcoming 3D-printing revolution in microfluidics. Lab on a chip. 16, pp.1720-1742. Birnbaum, N.S. and Aaronson, H.B. 2008. Dental impressions using 3D digital scanners: virtual becomes reality. Compend Contin Educ Dent. 29, pp.494, 496, 498-505. Blomstedt, P. 2013. Dental surgery in ancient Egypt. J Hist Dent. 61, pp.129-42. Bona, A.D., Borba, M., Benetti, P. and Cecchetti, D. 2007. Effect of surface treatments on the bond strength of a zirconia-reinforced ceramic to composite resin. Brazilian Oral Research. 21, pp.10-15. Bona, A.D. and Kelly, J.R. 2008. The Clinical Success Of All-Ceramic Restorations. The Journal of the American Dental Association. 139, S8-S13. Bona, A.D., Pecho, O.E. and Alessandretti, R. 2015. Zirconia as a Dental Biomaterial. Materials (Basel, Switzerland). 8, pp.4978-4991. Bothe, R.T.B., K.E.; Davenport, H.A. 1940. Reaction of bone to multiple metallic implants. Surg Gynecol Obstet. 71, pp.598-602. Braian, M. and Wennerberg, A. 2019. Trueness and precision of 5 intraoral scanners for scanning edentulous and dentate complete-arch mandibular casts: A comparative in vitro study. The Journal of Prosthetic Dentistry. 122, 129-136.e2. Brånemark, P.I. 1983. Osseointegration and its experimental background. J Prosthet Dent. 50, pp.399-410. Brenes, C., Renne, W., Tolbert, T. and Fantaski, L. 2020. Effect of Print Angulation on Surface Roughness of 3D-Printed Models. Compend Contin Educ Dent. 41, e1-e4. Brodala, N. 2009. Flapless surgery and its effect on dental implant outcomes. International Journal of Oral Maxillofacial Implants. 24, pp.118-125. Brown, G.B., Currier, G.F., Kadioglu, O. and Kierl, J.P. 2018. Accuracy of 3-dimensional printed dental models reconstructed from digital intraoral impressions. American Journal of Orthodontics and Dentofacial Orthopedics. 154, pp.733-739. Buda, M., Bratos, M. and Sorensen, J.A. 2018. Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts. The Journal of Prosthetic Dentistry. 120, pp.913-918. Camlog. 2017. Guided surgery Sleeves. [Online]. [Accessed 10 Sept 2017]. Available from: https://www.biohorizonscamlog.com/en/portfolio/implant-systems/camlog/surgery Canullo, L., Fedele, G.R., Iannello, G. and Jepsen, S. 2010. Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial. Clin Oral Implants Res. 21, pp.115-21. Carter, S.-S.D., Costa, P.F., Vaquette, C., Ivanovski, S., Hutmacher, D.W. and Malda, J. 2017. Additive Biomanufacturing: An Advanced Approach for Periodontal Tissue Regeneration. Annals of Biomedical Engineering. 45, pp.12-22. Ceyhan, J.A., Johnson, G.H. and Lepe, X. 2003. The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions. The Journal of Prosthetic Dentistry. 90, pp.143-149. Cha, M.-S., Lee, S.-W., Huh, Y.-H., Cho, L.-R. and Park, C.-J. 2017. Metal stain on monolithic zirconia restoration: A case report. The Journal of Advanced Prosthodontics. 9, pp.138-142. Chai, J., Chu, F.C., Chow, T.W., Shum, N.C. and Hui, W.W. 2006. Influence of dental status on nutritional status of geriatric patients in a convalescent and rehabilitation hospital. Int J Prosthodont. 19, pp.244-9. Chen, J., Cai, H., Ren, X., Suo, L., Pei, X. and Wan, Q. 2017. A Systematic Review of the Survival and Complication Rates of All-Ceramic Resin-Bonded Fixed Dental Prostheses. Journal of Prosthodontics. 27, pp.535-543. Chebib, N., Imamura, Y., El Osta, N., Srinivasan, M., Muller, F. and Maniewicz, S. 2022. Fit and retention of complete denture bases: Part II – conventional impressions versus digital scans: A clinical controlled crossover study. Journal of Prosthetic Dentistry. S0022-3913(22)00464-4. Advance online publication. Chen, L., Lin, W.-S., Polido, W.D., Eckert, G.J. and Morton, D. 2019. Accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates. The Journal of Prosthetic Dentistry. 122, pp.309-314. Cheng, W., Fuh, J.Y.H., Nee, A.Y.C., Wong, Y.S., Loh, H.T. and Miyazawa, T. 1995. Multi‐objective optimization of part‐building orientation in stereolithography. Rapid Prototyping Journal. 1, pp.12-23. Chockalingam, K., Jawahar, N. and Chandrasekhar, U. 2006. Influence of layer thickness on mechanical properties in stereolithography. Rapid Prototyping Journal. 12, pp.106-113. Choi, J.W. and Kim, N. 2015. Clinical application of three-dimensional printing technology in craniofacial plastic surgery. Archives of Plastic Surgery. 42, pp.267-277. Chun, J.-H., Tahk, J., Chun, Y.-S., Park, J.-M. and Kim, M. 2017. Analysis on the Accuracy of Intraoral Scanners: The Effects of Mandibular Anterior Interdental Space. Applied Sciences. 7, 719. Cochran, D.L., Hermann, J.S., Schenk, R.K., Higginbottom, F.L. and Buser, D. 1997. Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible. J Periodontol. 68, pp.186-98. Cole, D., Bencharit, S., Carrico, C.K., Arias, A. and Tüfekçi, E. 2019. Evaluation of fit for 3D-printed retainers compared with thermoform retainers. American Journal of Orthodontics and Dentofacial Orthopedics. 155, pp.592-599. Dawood, A., Marti, B.M., Sauret-Jackson, V. and Darwood, A. 2015. 3D printing in dentistry. British Dental Journal. 219, pp.521-529. Della Bona, A., Borba, M., Benetti, P., Pecho, O.E., Alessandretti, R., Mosele, J.C. and Mores, R.T. 2014. Adhesion to Dental Ceramics. Current Oral Health Reports. 1, pp.232-238. Della Bona, A., Donassollo, T.A., Demarco, F.F., Barrett, A.A. and Mecholsky, J.J. 2007. Characterization and surface treatment effects on topography of a glass-infiltrated alumina/zirconia-reinforced ceramic. Dental Materials. 23, pp.769-775. Dietrich, C.A., Ender, A., Baumgartner, S. and Mehl, A. 2017. A validation study of reconstructed rapid prototyping models produced by two technologies. The Angle Orthodontist. 87, pp.782-787. Dimitrov, D., Van Wijck, W., Schreve, K. and De Beer, N. 2006. Investigating the achievable accuracy of three-dimensional printing. Rapid Prototyping Journal. 12, pp.42-52. Dizon, J.R.C., Espera, A.H., Chen, Q. and Advincula, R.C. 2018. Mechanical characterization of 3D-printed polymers. Additive Manufacturing. 20, pp.44-67. Dong, J., Zhang, F., Wu, G.H., Zhang, W. and Yin, J. 2015. Measurement of mucosal thickness in denture-bearing area of edentulous mandible. Chin Med J (Engl). 5, pp.342-347. El Kholy K, Janner SFM, Schimmel M, Buser D. 2019. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin Implant Dent Relat Res. 21(1) pp.101-107. Elizabeth, B. 2014. 3D Printed Ceramics [Online]. Available at: http://www.materialise.com/blog/3d-printed-ceramics/ [Accessed May 7, 2019]. Ellis, J. S., Levine, A., Bedos, C., Mojon, P., Rosberger, Z., Feine, J., & Thomason, J. M. 2011. Refusal of implant supported mandibular overdentures by elderly patients. Gerodontology, 28(1), pp.62–68. Emir, F. and Ayyildiz, S. 2021. Accuracy evaluation of complete-arch models manufactured by three different 3D printing technologies: a three-dimensional analysis. Journal of Prosthodontic Research. 65, pp.365-370. Ender, A., Attin, T. and Mehl, A. 2016. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. The Journal of Prosthetic Dentistry. 115, pp.313-320. Ender, A. and Mehl, A. 2013. Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision. The Journal of Prosthetic Dentistry. 109, pp.121-128. Ericsson, I., Persson, L.G., Berglundh, T., Marinello, C.P., Lindhe, J. and Klinge, B. 1995. Different types of inflammatory reactions in peri-implant soft tissues. J Clin Periodontol. 22, pp.255-61. Ersoy, A.E., Turkyilmaz, I., Ozan, O. and McGlumphy, E.A. 2008. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. J Periodontol. 79, pp.1339-45. Esposito, M., Ekestubbe, A. and Gröndahl, K. 1993. Radiological evaluation of marginal bone loss at tooth surfaces facing single Brånemark implants. Clinical Oral Implants Research. 4, pp.151-157. Esposito, M., Hirsch, J.M., Lekholm, U. and Thomsen, P. 1998. Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology. European Journal of Oral Sciences. 106, pp.527-551. Etemad-Shahidi, Y., Qallandar, O.B., Evenden, J., Alifui-Segbaya, F. and Ahmed, K.E. 2020. Accuracy of 3-Dimensionally Printed Full-Arch Dental Models: A Systematic Review. Journal of Clinical Medicine. 9, 3357. Ettl, S., Arold, O., Vogt, P., Hybl, O., Yang, Z., Xie, W. and Häusler, G. 2009. “Flying Triangulation”: A motion-robust optical 3D sensor principle. Fringe 2009. Springer Berlin Heidelberg. Evans, C.D.J. and Chen, S.T. 2007. Esthetic outcomes of immediate implant placements. Clinical Oral Implants Research. 0, 071025001541009 Exocad. 2019. CBCT To CBCT Dual Scan Data Matching with ExoPlan Software. [Online]. [Accessed 10 May 2019]. Available from: https://exocad.com/our-products/exoplan-galway Exocad. 2020. CAD Software. [Online]. [Accessed 20 Feb 2020]. Available from: https://exocad.com/ Farjood, E., Vojdani, M., Torabi, K. & Khaledi, A.A.R., 2017. 'Marginal and internal fit of metal copings fabricated with rapid prototyping and conventional waxing', The Journal of Prosthetic Dentistry, 117, pp.164-170. Farman, A.G. & Scarfe, W.C., 2006. 'Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography', American Journal of Orthodontics and Dentofacial Orthopedics, 130, pp.257-265. Favero, C.S., English, J.D., Cozad, B.E., Wirthlin, J.O., Short, M.M. & Kasper, F.K., 2017. 'Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models', American Journal of Orthodontics and Dentofacial Orthopedics, 152, pp.557-565. Fernandes, N., Van Den Heever, J., Hoogendijk, C., Botha, S., Booysen, G. & Els, J., 2016. 'Reconstruction of an Extensive Midfacial Defect Using Additive Manufacturing Techniques', Journal of Prosthodontics, 25, pp.589-594. Fisher B, M.S., 2013. 'Simultaneous registration of multi-view range images with adaptive kernel density estimation', Institute of Mathematics and its Applications, pp.31-62. Flügge, T.V., Schlager, S., Nelson, K., Nahles, S. & Metzger, M.C., 2013. 'Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner', American Journal of Orthodontics and Dentofacial Orthopedics, 144, pp.471-478. Formlabs. 2019. 3D Printing Equipment. [Online]. [Accessed 10 Feb 2019]. Available from: https://formlabs.com/uk/ Fukazawa, S., Odaira, C. & Kondo, H., 2017. 'Investigation of accuracy and reproducibility of abutment position by intraoral scanners', Journal of Prosthodontic Research, 61, pp.450-459. Gargiulo, A.W., Wentz, F.M. & Orban, B., 1961. 'Dimensions and Relations of the Dentogingival Junction in Humans', Journal of Periodontology, 32, pp.261-267. Gebhardt, A., Schmidt, F.-M., Hötter, J.-S., Sokalla, W. & Sokalla, P., 2010. 'Additive Manufacturing by selective laser melting the realizer desktop machine and its application for the dental industry', Physics Procedia, 5, pp.543-549. George, D. & Mallery, P., 2019. IBM SPSS Statistics Processes for Mac. IBM SPSS Statistics 26 Step by Step. Routledge. Gopichander, N., Halini Kumarai, K.V. & Vasanthakumar, M., 2015. 'Effect of polyester fiber reinforcement on the mechanical properties of interim fixed partial dentures', The Saudi Dental Journal, 27, pp.194-200. Grandin, H.M., Berner, S. & Dard, M., 2012. 'A Review of Titanium Zirconium (TiZr) Alloys for Use in Endosseous Dental Implants', Materials, 5, pp.1348-1360. Greenfield, E.J., 1913. 'Implantation of artificial crown and bridge abutments', Dent Cadmos., 55. Groth, C., Kravitz, N.D., & Shirck, J.M., 2018. 'Incorporating three-dimensional printing in orthodontics', 52, 1, pp.28-33. Guess, P.C., Schultheis, S., Bonfante, E.A., Coelho, P.G., Ferencz, J.L. & Silva, N.R.F.A., 2011. 'All-Ceramic Systems: Laboratory and Clinical Performance', Dental Clinics of North America, 55, pp.333-352. Hamza, T.A., Johnston, W.M. & Schricker, S.R., 2014. 'Effect of polyhedral silsesquioxane (POSS) on the flexural strength and color of interim materials', The Journal of Prosthetic Dentistry, 112, pp.228-234. Han, T., Kundu, S., Nag, A. & Xu, Y., 2019. '3D Printed Sensors for Biomedical Applications: A Review', Sensors (Basel, Switzerland), 19, 1706. Hayden, H.C., 2015. 'Exploration of Materials Used in 3-Dimensional Printing for the Dental Industry'. Hazeveld, A., Huddleston Slater, J.J.R. & Ren, Y., 2014. 'Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques', American Journal of Orthodontics and Dentofacial Orthopedics, 145, pp.108-115. Hermann, J.S., Cochran, D.L., Nummikoski, P.V. & Buser, D., 1997. 'Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible', Journal of Periodontology, 68, pp.1117-1130. IDDA. 2018. 3d printer. [Online]. [Accessed 18 Sept 2018]. Available from: https://www.IDDA.org IDDA. 2019. 3D Models [Online]. [Accessed 11 June 2019]. Available from: https://www.IDDA.org ISO 12836. Dentistry-Digitizing devices for CAD/CAM systems for indirect dental restorations-Test methods for assessing accuracy. Geneva; Switzerland: International Standards Organization (ISO); 2015. [Accessed July 31, 2018]. Keeling, A. The Positional Change Calculator. Created at Leeds University. 2021 Lansard, M., 2018. 3D Printing For the Dental Industry. ANIWAA.Inc. Lazzara, R.J. and Porter, S.S., 2006. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent, 26, pp.9-17. Lebon, N., Tapie, L., Vennat, E. and Mawussi, B., 2015. Influence of CAD/CAM tool and material on tool wear and roughness of dental prostheses after milling. The Journal of Prosthetic Dentistry, 114, pp.236-247. Lee JH, Park JM, Kim SM, Kim MJ, Lee JH, Kim MJ. 2013 An assessment of template-guided implant surgery in terms of accuracy and related factors. J Adv Prosthodont. 5(4) pp.440-7. Lee, J.-H., Yun, J.-H., Han, J.-S., Yeo, I.-S.L. and Yoon, H.-I., 2019. Repeatability of Intraoral Scanners for Complete Arch Scan of Partially Edentulous Dentitions: An In Vitro Study. Journal of clinical medicine, 8, 1187. Ligon, S.C., Liska, R., Stampfl, J., Gurr, M. and Mülhaupt, R., 2017. Polymers for 3D Printing and Customized Additive Manufacturing. Chemical reviews, 117, pp.10212-10290. Lim, J.-H., Park, J.-M., Kim, M., Heo, S.-J. and Myung, J.-Y., 2018. Comparison of digital intraoral scanner reproducibility and image trueness considering repetitive experience. The Journal of Prosthetic Dentistry, 119, pp.225-232. Loflin, W.A., English, J.D., Borders, C., Harris, L.M., Moon, A., Holland, J.N. and Kasper, F.K., 2019. Effect of print layer height on the assessment of 3D-printed models. American Journal of Orthodontics and Dentofacial Orthopedics, 156, pp.283-289. Ludlow, J.B., Laster, W.S., See, M., Bailey, L.T.J. and Hershey, H.G., 2007. Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics, 103, pp.534-542. Lund, H., Gröndahl, K. and Gröndahl, H.-G., 2010. Cone Beam Computed Tomography for Assessment of Root Length and Marginal Bone Level during Orthodontic Treatment. The Angle Orthodontist, 80, pp.466-473. Mack, A., 1971. Full Dentures., 11. Mahamood, S., Khader, M.A. and Ali, H., 2016. Applications of 3-D printing in orthodontics: a review. International Journal of Scientific Study, 3, pp.267-270. Mandelaris, G.R., 2010. Computer-guided implant dentistry for precise implant placement: combining specialized stereolithographically generated drilling guides and surgical implant instrumentation. The International journal of periodontics & restorative dentistry, 30, 275. Mangano, F., Gandolfi, A., Luongo, G. and Logozzo, S., 2017. Intraoral scanners in dentistry: a review of the current literature. BMC oral health, 17, 149-149. Mangano, F.G., Admakin, O., Bonacina, M., Biaggini, F., Farronato, D. and Lerner, H., 2020. Accuracy of 6 Desktop 3D Printers in Dentistry: A Comparative In Vitro Study. Eur J Prosthodont Restor Dent, 28, pp.75-85. Mangano, F.G., Hauschild, U., Veronesi, G., Imburgia, M., Mangano, C. and Admakin, O., 2019. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. BMC oral health, 19, 101-101. Mangano, F.G., Veronesi, G., Hauschild, U., Mijiritsky, E. and Mangano, C., 2016. Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study. PloS one, 11, e0163107-e0163107. Mansour, S., Gilbert, M. and Hague, R., 2007. A study of the impact of short-term ageing on the mechanical properties of a stereolithography resin. Materials Science and Engineering: A, 447, pp.277-284. Mao, Z., Park, K., Lee, K. and Li, X., 2013. Robust surface reconstruction of teeth from raw pointsets. International Journal for Numerical Methods in Biomedical Engineering, 30, pp.382-396. McGill, N., 2002. The McGill Consensus Statement on Overdentures: Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology, 19, pp.3-4. Medina-Sotomayor, P., Pascual-Moscardo, A. and Camps A, I., 2019. Accuracy of 4 digital scanning systems on prepared teeth digitally isolated from a complete dental arch. The Journal of Prosthetic Dentistry, 121, pp.811-820. Menini, M., Setti, P., Pera, F., Pera, P. and Pesce, P., 2017. Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure. Clinical Oral Investigations, 22, pp.1253-1262. Misch, C.E., 1990. Density of bone: Effect on treatment plans, surgical approach, healing, and progressive bone loading. International Journal of Oral Implantology, 6(2), pp.23-31. Miyazaki, T., Nakamura, T., Matsumura, H., Ban, S. and Kobayashi, T., 2013. Current status of zirconia restoration. Journal of Prosthodontic Research, 57, pp.236-261. Moörmann, W.H., 2006. The evolution of the CEREC system. The Journal of the American Dental Association, 137, pp.7S-13S. Murray, J.J., 2011. Adult Dental Health Surveys: 40 years on. British Dental Journal, 211, pp.407-408. N. Turner, B., Strong, R. and A. Gold, S., 2014. A review of melt extrusion additive manufacturing processes: I. Process design and modeling. Rapid Prototyping Journal, 20, pp.192-204. Nagy, Z.A., Simon, B., Tóth, Z. and Vág, J., 2018. Evaluating the efficiency of the Dental Teacher system as a digital preclinical teaching tool. European Journal of Dental Education, 22, e619-e623. Nasef, A.A., El-Beialy, A.R., Eid, F.H.K. and Mostafa, Y.A., 2017. Accuracy of Orthodontic 3D Printed Retainers versus Thermoformed Retainers. Open Journal of Medical Imaging, 07, pp.169-179. Nayar, S., Bhuminathan, S. and Bhat, W.M., 2015a. Rapid prototyping and stereolithography in dentistry. Journal of pharmacy & bioallied sciences, 7, S216-S219. Nayar, S., Ganesh, R. and Santhosh, S., 2015b. Fiber reinforced composites in prosthodontics - A systematic review. Journal of pharmacy & bioallied sciences, 7, S220-S222. Nedelcu, R., Olsson, P., Nyström, I., Rydén, J. and Thor, A., 2018. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method. Journal of Dentistry, 69, pp.110-118. Nedelcu RG, P.A., 2014. Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis. J Prosthet Dent, 112, pp.1461-1471. Nedelcu, R.G. and Persson, A.S.K., 2014. Scanning accuracy and precision in 4 intraoral scanners: An in vitro comparison based on 3-dimensional analysis. The Journal of Prosthetic Dentistry, 112, pp.1461-1471. Ng, J., Ruse, D. and Wyatt, C., 2014. A comparison of the marginal fit of crowns fabricated with digital and conventional methods. The Journal of Prosthetic Dentistry, 112, pp.555-560. Nickenig, H.-J. and Eitner, S., 2007. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates. Journal of Cranio-Maxillofacial Surgery, 35, pp.207-211. Oba, Y., Koizumi, H., Nakayama, D., Ishii, T., Akazawa, N. and Matsumura, H., 2014. Effect of silane and phosphate primers on the adhesive performance of atri-n-butylborane initiated luting agent bonded to zirconia. Dental Materials Journal, 33, pp.226-232. Oberoi, G., Nitsch, S., Edelmayer, M., Janjić, K., Müller, A.S. and Agis, H., 2018. 3D Printing-Encompassing the Facets of Dentistry. Frontiers in bioengineering and biotechnology, 6, 172-172. Oh KC, Shim JS, Park JM. 2021 In Vitro Comparison between Metal Sleeve-Free and Metal Sleeve-Incorporated 3D-Printed Computer-Assisted Implant Surgical Guides. Materials (Basel). 29;14(3) pp.615. Osstem. 2017. Guided surgery Kit. [Online]. [Accessed 10 Sept 2017]. Available from: https://www.osstemuk.com/surgery-kits/ Ottemer, X. and Colton, J.S., 2002. Effects of aging on epoxy‐based rapid tooling materials. Rapid Prototyping Journal, 8, pp.215-223. Park, G.-H., Son, K. & Lee, K.-B. 2019. Feasibility of using an intraoral scanner for a complete-arch digital scan. The Journal of Prosthetic Dentistry, 121, pp.803-810. Park, J.-M., Ahn, J.-S., Cha, H.-S. & Lee, J.-H. 2018. Wear Resistance of 3D Printing Resin Material Opposing Zirconia and Metal Antagonists. Materials (Basel, Switzerland), 11, 1043. Park, M.-E. & Shin, S.-Y. 2018. Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers. The Journal of Prosthetic Dentistry, 119, pp.861.e1-861.e7. Park, S., Kang, H.C., Lee, J., Shin, J. & Shin, Y.G. 2015. An enhanced method for registration of dental surfaces partially scanned by a 3D dental laser scanning. Computer Methods and Programs in Biomedicine, 118, pp.11-22. Patras, M., Naka, O., Doukoudakis, S. & Pissiotis, A. 2011. Management of Provisional Restorations' Deficiencies: A Literature Review. Journal of Esthetic and Restorative Dentistry, 24, pp.26-38. Patzelt, S.B.M., Bishti, S., Stampf, S. & Att, W. 2014. Accuracy of computer-aided design/computer-aided manufacturing–generated dental casts based on intraoral scanner data. The Journal of the American Dental Association, 145, pp.1133-1140. Patzelt, S.B.M., Emmanoulidi, A., Stampf, S., Strub, J.R. & Att, W. 2013a. Accuracy of full-arch scans using intraoral scanners. Clinical Oral Investigations, 18, pp.1687-1694. Patzelt, S.B.M., Vonau, S., Stampf, S. & Att, W. 2013b. Assessing the feasibility and accuracy of digitizing edentulous jaws. The Journal of the American Dental Association, 144, pp.914-920. Pauwels, R., Araki, K., Siewerdsen, J.H. & Thongvigitmanee, S.S. 2015. Technical aspects of dental CBCT: state of the art. Dentomaxillofacial Radiology, 44, 20140224. Peñate, L., Basilio, J., Roig, M. & Mercadé, M. 2015. Comparative study of interim materials for direct fixed dental prostheses and their fabrication with CAD/CAM technique. The Journal of Prosthetic Dentistry, 114, pp.248-253. Pesce, P., Pera, F., Setti, P. & Menini, M. 2018. Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation. The International Journal of Prosthodontics, 31, pp.171-175. Piedra Cascón, W., Parra Nuñez, A., Charlén Díez, I. & Revilla-León, M. 2018. Laboratory workflow to obtain long-term injected resin composite interim restorations from an additive manufactured esthetic diagnostic template. Journal of Esthetic and Restorative Dentistry, 31, pp.13-19. Pinsky, H.M., Dyda, S., Pinsky, R.W., Misch, K.A. & Sarment, D.P. 2006. Accuracy of three-dimensional measurements using cone-beam CT. Dentomaxillofacial Radiology, 35, pp.410-416. Prasad, S., Kader, N.A., Sujatha, G., Raj, T. & Patil, S. 2018. 3D printing in dentistry. Journal of 3D Printing in Medicine, 2, pp.89-91. PSM. 2018. Benefit System. [Online]. [Accessed 18 Sept 2018]. Available from: https://psm-medical.com/ Puebla, K., Arcaute, K., Quintana, R. & Wicker, R.B. 2012. Effects of environmental conditions, aging, and build orientations on the mechanical properties of ASTM type I specimens manufactured via stereolithography. Rapid Prototyping Journal, 18, pp.374-388. Rayyan, M.M., Aboushelib, M., Sayed, N.M., Ibrahim, A. & Jimbo, R. 2015. Comparison of interim restorations fabricated by CAD/CAM with those fabricated manually. The Journal of Prosthetic Dentistry, 114, pp.414-419. Rech-Ortega, C., Fernández-Estevan, L., Solá-Ruíz, M.F., Agustín-Panadero, R. & Labaig-Rueda, C. 2019. Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material versus intraoral scanner. Medicina Oral, Patologia Oral y Cirugia Bucal, 24, pp.e89-e95. Rehmann, P., Sichwardt, V. & Wöstmann, B. 2017. Intraoral Scanning Systems: Need for Maintenance. The International Journal of Prosthodontics, pp.27-29. Revilla-León, M., Gonzalez-Martín, Ó., Pérez López, J., Sánchez-Rubio, J.L. & Özcan, M. 2017. Position Accuracy of Implant Analogs on 3D Printed Polymer versus Conventional Dental Stone Casts Measured Using a Coordinate Measuring Machine. Journal of Prosthodontics, 27, pp.560-567. Revilla-León, M., Meyers, M.J., Zandinejad, A. & Özcan, M. 2018. A review on chemical composition, mechanical properties, and manufacturing work flow of additively manufactured current polymers for interim dental restorations. Journal of Esthetic and Restorative Dentistry, 31, pp.51-57. Revilla-León, M. & Özcan, M. 2017. Additive Manufacturing Technologies Used for 3D Metal Printing in Dentistry. Current Oral Health Reports, 4, pp.201-208. Reza, M. 2007. Nanomaterials and Nanosystems for Biomedical Applications. SpringerLink: Springer e-Books. Richert, R., Goujat, A., Venet, L., Viguie, G., Viennot, S., Robinson, P., Farges, J.-C., Fages, M. & Ducret, M. 2017. Intraoral Scanner Technologies: A Review to Make a Successful Impression. Journal of Healthcare Engineering, 2017, pp.8427595-8427595. Ritter, L., Reiz, S.D., Rothamel, D., Dreiseidler, T., Karapetian, V., Scheer, M. & Zöller, J.E. 2011. Registration accuracy of three-dimensional surface and cone beam computed tomography data for virtual implant planning. Clinical Oral Implants Research, 23, pp.447-452. Rodríguez-Ciurana, X., Vela-Nebot, X., Segalà-Torres, M., Calvo-Guirado, J.L., Cambra, J., Méndez-Blanco, V. & Tarnow, D.P. 2009. The effect of interimplant distance on the height of the interimplant bone crest when using platform-switched implants. Int J Periodontics Restorative Dent, 29, pp.141-51. Rovelo, P. 2016. Additive Manufacturing in the Medical and Dental Technology Industries. Available: https://3dprintingindustry.com/news/additive-manufacturing-medical-dental-technology-industries-80348/ [Accessed May 9, 2019]. Sakornwimon, N. & Leevailoj, C. 2017. Clinical marginal fit of zirconia crowns and patients’ preferences for impression techniques using intraoral digital scanner versus polyvinyl siloxane material. The Journal of Prosthetic Dentistry, 118, pp.386-391. Sason, G.K., Mistry, G., Tabassum, R. & Shetty, O. 2018. A comparative evaluation of intraoral and extraoral digital impressions: An in vivo study. Journal of Indian Prosthodontic Society, 18, pp.108-116. Schneider, D., Marquardt, P., Zwahlen, M. & Jung, R.E. 2009. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clinical Oral Implants Research, 20, pp.73-86. Schnutenhaus, S., Gröller, S., Luthardt, R.G. & Rudolph, H. 2018. Accuracy of the match between cone beam computed tomography and model scan data in template-guided implant planning: A prospective controlled clinical study. Clinical Implant Dentistry and Related Research, 20, pp.541-549. Schulze, R., Heil, U., Gross, D., Bruellmann, D. D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. 2011) Artefacts in CBCT: a review. Dento maxillo facial radiology. 40(5), pp.265–273. Schweiger, J., Edelhoff, D., & Güth, J. F. 2021. 3D Printing in Digital Prosthetic Dentistry: An Overview of Recent Developments in Additive Manufacturing. Journal of clinical medicine, 10, pp.9 Scopigno, R., Cignoni, P., Pietroni, N., Callieri, M. & Dellepiane, M. 2015. Digital Fabrication Techniques for Cultural Heritage: A Survey. Computer Graphics Forum, 36, pp.6-21. Siciliano, B. and Khatib, O. (eds.) 2016. Springer Handbook of Robotics. Springer. Sirona, D. Ineos X5 Lab Scanner Information [Online]. Available: https://www.dentsplysirona.com/en/explore/lab/cad-cam-equipment-dental-lab/scan.html [Accessed]. Spray, J.R., Black, C.G., Morris, H.F. & Ochi, S. 2000. The Influence of Bone Thickness on Facial Marginal Bone Response: Stage 1 Placement Through Stage 2 Uncovering. Annals of Periodontology, 5, pp.119-128. Stansbury, J.W. & Idacavage, M.J. 2016. 3D printing with polymers: Challenges among expanding options and opportunities. Dental Materials, 32, pp.54-64. Steele, J.G., Treasure, E.T., O'Sullivan, I., Morris, J. & Murray, J.J. 2012. Adult Dental Health Survey 2009: transformations in British oral health 1968–2009. British Dental Journal, 213, pp.523-527. Stewart, M. & Bagby, M. 2018. Clinical aspects of dental materials: Theory, practice, and cases. Wolters Kluwer Health/Lippincott Williams & Wilkins. Stratasys. 2017. Stratasys and Siemens to improve 3D printing volume production. Reinforced Plastics, 61, pp.10-11. Straumann. 2017. Guided surgery Spoons. [Online]. [Accessed 10 Sept 2017]. Available from: https://www.straumann.com/gb/en/dental-professionals/products-and-solutions/guided-surgery.html Sweeney, S., Smith, D.K. & Messersmith, M. 2015. Comparison of 5 types of interocclusal recording materials on the accuracy of articulation of digital models. American Journal of Orthodontics and Dentofacial Orthopedics, 148, pp.245-252. Swissmeda. 2017. User Guide for SMOP Pre-Post Implant position comparison Version 2.12. Switzerland. Sykes, L. 2004. Applications of rapid prototyping technology in maxillofacial prosthetics. International Journal of Prosthodontics, 14. Szeliski, R. 2010. Computer Vision: Algorithms and Applications. Springer. Tahayeri, A., Morgan, M., Fugolin, A.P., Bompolaki, D., Athirasala, A., Pfeifer, C.S., Ferracane, J.L. & Bertassoni, L.E. 2018. 3D printed versus conventionally cured provisional crown and bridge dental materials. Dental Materials: Official Publication of the Academy of Dental Materials, 34, pp.192-200. Tapie, L., Lebon, N., Mawussi, B., Fron-Chabouis, H., Duret, F. & Attal, J.P. 2015. Understanding dental CAD/CAM for restorations- accuracy from a mechanical engineering viewpoint. Int J Comput Dent, 18, pp.334-367. Tarnow, D.P., Cho, S.C. & Wallace, S.S. 2000. The Effect of Inter-Implant Distance on the Height of Inter-Implant Bone Crest. Journal of Periodontology, 71, pp.546-549. Teughels, W., Merheb, J. & Quirynen, M. 2009. Critical horizontal dimensions of interproximal and buccal bone around implants for optimal aesthetic outcomes: a systematic review. Clinical Oral Implants Research, 20, pp.134-145. Thomason, J.M., Feine, J., Exley, C., Moynihan, P., Müller, F., Naert, I., Ellis, J.S., Barclay, C., Butterworth, C., Scott, B., Lynch, C., Stewardson, D., Smith, P., Welfare, R., Hyde, T., McAndrew, R., Fenlon, M., Barclay, S. & Barker, D. 2009. The York consensus statement on implant-supported overdentures. European Journal of Prosthodontic and Restorative Dentistry. Ting-Shu, S. & Jian, S. 2014. Intraoral Digital Impression Technique: A Review. Journal of Prosthodontics, 24, pp.313-321. Torabi, K., Farjood, E. & Hamedani, S. 2015. Rapid Prototyping Technologies and their Applications in Prosthodontics, a Review of Literature. Journal of Dentistry (Shiraz, Iran), 16, pp.1-9. Tsakos, G., Herrick, K., Sheiham, A. & Watt, R.G. 2010. Edentulism and fruit and vegetable intake in low-income adults. J Dent Res., May, pp.462-467. Uhm, S.-H., Kim, J.-H., Jiang, H.B., Woo, C.-W., Chang, M., Kim, K.-N., Bae, J.-M. & Oh, S. 2017. Evaluation of the accuracy and precision of four intraoral scanners with 70% reduced inlay and four-unit bridge models of international standard. Dental Materials Journal, 36, pp.27-34. Urrios, A., Parra-Cabrera, C., Bhattacharjee, N., Gonzalez-Suarez, A.M., Rigat-Brugarolas, L.G., Nallapatti, U., Samitier, J., DeForest, C.A., Posas, F., Garcia-Cordero, J.L. & Folch, A. 2016. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab on a Chip, 16, pp.2287-2294. Vaidyanathan, T.K., Vaidyanathan, J. & Arghavani, D. 2016. Elastic, viscoelastic and viscoplastic contributions to compliance during deformation under stress in prosthodontic temporization materials. Acta Biomaterialia Odontologica Scandinavica, 2, pp.108-117. Van Assche, N., Vercruyssen, M., Coucke, W., Teughels, W., Jacobs, R. & Quirynen, M. 2012. Accuracy of computer-aided implant placement. Clinical Oral Implants Research, 23, pp.112-123. Van Steenberghe, D. 2005. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clinical Implant Dentistry and Related Research, 7, pp.111-120. Vos, T., Flaxman, A.D., Naghavi, M., et al. 2012. Years lived with disability (YLDs) for 1160 sequelae of 289 diseases and injuries 1990-2010: a systematic analysis for the Global Burden of Disease Study 2010 [published correction appears in Lancet. 2013 Feb 23;381(9867):628. AlMazroa, Mohammad A [added]; Memish, Ziad A [added]]. Lancet, 380(9859), pp.2163-2196 Witkowski, S., Komine, F. & Gerds, T. 2006. Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques. The Journal of Prosthetic Dentistry, 96, pp.47-52."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/33848/1/Adam%20Nulty%20PhD%20Thesis.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Background and Aims: The treatment of edentulous arches with dental implants offers significant benefits over traditional removable prosthetics. However, current implant placement methods, whether freehand or guided, present challenges in terms of accuracy, invasiveness, and postoperative discomfort. The primary aim of this thesis was to address the concern of placement inaccuracy in fully edentulous patients and introduce a more precise method. Materials and Methods: A novel approach, the \"Fixed Edentulous Implant Guide\" (FEIG), is introduced. Unlike conventional tooth-based guides, the FEIG employs three two-part screws to aid matching of reference points to precisely align digital impressions with CBCT scans during virtual planning. This research explored the method's efficacy through in vitro studies and comprehensive literature reviews along with a novel approach to the calculation of the implant position used in the final study. Results: The findings of both the preliminary and final studies show that the novel method presented in this thesis is more accurate than both existing methods of edentulous guided surgery (mucosal borne and bone guides) and dentate guided implant surgery. Through statistical analysis with an independent samples t-test, the final study revealed that the significance is less than than 0.05 for each comparison between the novel FEIG method and the conventional mucosal borne edentulous guided surgery (p<0.001), and a statistically significant difference between the two methods is concluded. The evidence suggests that this approach is both safe and precise, especially when referencing the model to the CBCT scan. Conclusions: The final objective of the thesis was to examine whether it is both safe and accurate to place implants with flapless surgery with this new method that references the model to the CBCT scan. The study findings suggest that this statement can be upheld, and given the accuracy in terms of trueness and precision, it is concluded that the novel method provides an accurate method to place implants in an edentulous arch. Furthermore, as guided implant surgery can often mean that bone can be utilised in an angular or unconventional approach to avoid grafting, using this method may mean that patients with a medical contraindication to conventional flapped surgery may also benefit from full arch rehabilitation."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Accuracy of a New Method To Combine Digital Impressions With CBCT Scans Of The Edentulous Mandible"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hyde, Paul","Keeling, Andrew","Wood, David"],"dc:creator":["Nulty, Adam Brian"],"dc:date":["2023-08"],"dc:date.issued":["2023-08"],"dc:description.abstract":["Background and Aims: The treatment of edentulous arches with dental implants offers significant benefits over traditional removable prosthetics. However, current implant placement methods, whether freehand or guided, present challenges in terms of accuracy, invasiveness, and postoperative discomfort. The primary aim of this thesis was to address the concern of placement inaccuracy in fully edentulous patients and introduce a more precise method. Materials and Methods: A novel approach, the \"Fixed Edentulous Implant Guide\" (FEIG), is introduced. Unlike conventional tooth-based guides, the FEIG employs three two-part screws to aid matching of reference points to precisely align digital impressions with CBCT scans during virtual planning. This research explored the method's efficacy through in vitro studies and comprehensive literature reviews along with a novel approach to the calculation of the implant position used in the final study. Results: The findings of both the preliminary and final studies show that the novel method presented in this thesis is more accurate than both existing methods of edentulous guided surgery (mucosal borne and bone guides) and dentate guided implant surgery. Through statistical analysis with an independent samples t-test, the final study revealed that the significance is less than than 0.05 for each comparison between the novel FEIG method and the conventional mucosal borne edentulous guided surgery (p<0.001), and a statistically significant difference between the two methods is concluded. The evidence suggests that this approach is both safe and precise, especially when referencing the model to the CBCT scan. Conclusions: The final objective of the thesis was to examine whether it is both safe and accurate to place implants with flapless surgery with this new method that references the model to the CBCT scan. The study findings suggest that this statement can be upheld, and given the accuracy in terms of trueness and precision, it is concluded that the novel method provides an accurate method to place implants in an edentulous arch. Furthermore, as guided implant surgery can often mean that bone can be utilised in an angular or unconventional approach to avoid grafting, using this method may mean that patients with a medical contraindication to conventional flapped surgery may also benefit from full arch rehabilitation."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/33848/1/Adam%20Nulty%20PhD%20Thesis.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Fixed and Removable Prosthodontics (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/33848/"],"dc:relation.references":["Abdulmohsen, B., Parker, S., Braden, M. and Patel, M.P. 2016. A study to investigate and compare the physicomechanical properties of experimental and commercial temporary crown and bridge materials. Dental Materials. 32, pp.200-210. Abduo, J. 2019. Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses. The Journal of Advanced Prosthodontics. 11, pp.138-146. Akyalcin, S., Cozad, B.E., English, J.D., Colville, C.D. and Laman, S. 2013. Diagnostic accuracy of impression-free digital models. American Journal of Orthodontics and Dentofacial Orthopedics. 144, pp.916-922. Al Mortadi, N., Jones, Q., Eggbeer, D., Lewis, J. and Williams, R.J. 2015. Fabrication of a resin appliance with alloy components using digital technology without an analog impression. American Journal of Orthodontics and Dentofacial Orthopedics. 148, pp.862-867. Al-Imam, H., Gram, M., Benetti, A.R. and Gotfredsen, K. 2018. Accuracy of stereolithography additive casts used in a digital workflow. The Journal of Prosthetic Dentistry. 119, pp.580-585. Alharbi, N., Osman, R. and Wismeijer, D. 2016a. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations. The Journal of Prosthetic Dentistry. 115, pp.760-767. Alharbi, N., Osman, R. and Wismeijer, D. 2016b. Factors Influencing the Dimensional Accuracy of 3D-Printed Full-Coverage Dental Restorations Using Stereolithography Technology. The International Journal of Prosthodontics. 29, pp.503-510. Alharbi, N., van de Veen, A.J., Wismeijer, D. and Osman, R.B. 2018. Build angle and its influence on the flexure strength of stereolithography printed hybrid resin material. An in vitro study and a fractographic analysis. Materials Technology. 34, pp.12-17. Allen, P.F., Thomason, J.M., Jepson, N.J., Nohl, F., Smith, D.G. and Ellis, J. 2006a. A randomized controlled trial of implant-retained mandibular overdentures. J Dent Res. 85, pp.547-51. Allen, P.F., Thomason, J.M., Jepson, N.J.A., Nohl, F., Smith, D.G. and Ellis, J. 2006b. A Randomized Controlled Trial of Implant-retained Mandibular Overdentures. Journal of Dental Research. 85, pp.547-551. Alp, G., Murat, S. and Yilmaz, B. 2018. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers. Journal of Prosthodontics. 28, e491-e495. Amin, S., Weber, H.P., Finkelman, M., El Rafie, K., Kudara, Y. and Papaspyridakos, P. 2016. Digital vs. conventional full-arch implant impressions: a comparative study. Clinical Oral Implants Research. 28, pp.1360-1367. Andonović, V. 2010. Growing rapid prototyping as a technology in dental medicine. Mechanical Engineering Scientific Journal. 29, pp.31-39. Andriessen, F.S., Rijkens, D.R., van der Meer, W.J. and Wismeijer, D.W. 2014. Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study. The Journal of Prosthetic Dentistry. 111, pp.186-194. Anusavice, K.J., Phillips, R.W., Shen, C., and Rawls, H.R. 2013. Phillips' science of dental materials. Arisan, V., Karabuda, Z.C. and Ozdemir, T. 2010. Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. J Periodontol. 81, pp.43-51. Asiga. Available: https://www.asiga.com/products/materials/ [Accessed May 9, 2019]. Astudillo-Rubio, D., Delgado-Gaete, A., Bellot-Arcís, C., Montiel-Company, J.M., Pascual-Moscardó, A. and Almerich-Silla, J.M. 2018. Mechanical properties of provisional dental materials: A systematic review and meta-analysis. PloS one. 13, e0193162-e0193162. Atieh, M.A., Ibrahim, H.M. and Atieh, A.H. 2010. Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis. J Periodontol. 81, pp.1350-66. Atieh, M.A., Ritter, A.V., Ko, C.-C. and Duqum, I. 2017. Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance. The Journal of prosthetic dentistry. 118, pp.400-405. Atwood, D.A., 1971. Reduction of residual ridges: a major oral disease entity. J Prosthet Dent. Sep;26(3) pp. 266-79. Azari, A. and Nikzad, S. 2009. The evolution of rapid prototyping in dentistry: a review. Rapid Prototyping Journal. 15, pp.216-225. Bajraktarova-Valjakova, E., Korunoska-Stevkovska, V., Kapusevska, B., Gigovski, N., Bajraktarova-Misevska, C. and Grozdanov, A. 2018. Contemporary Dental Ceramic Materials, A Review: Chemical Composition, Physical and Mechanical Properties, Indications for Use. Open access Macedonian journal of medical sciences. 6, pp.1742-1755. Balkenhol, M., Köhler, H., Orbach, K. and Wöstmann, B. 2009. Fracture toughness of cross-linked and non-cross-linked temporary crown and fixed partial denture materials. Dental Materials. 25, pp.917-928. Basker, R.M., Davenport J.C., Tomlin, H.R. 1976. Prosthetic Treatment of the Edentulous Patient. MacMillan, London. Becker K, Schmücker U, Schwarz F, Drescher D. 2018. Accuracy and eligibility of CBCT to digitize dental plaster casts. Clin Oral Investig. 22(4), pp.1817-1823. doi: 10.1007/s00784-017-2277-x. Epub 2017 Dec 2. PMID: 29196949. Becker, K., Wilmes, B., Grandjean, C. and Drescher, D. 2018. Impact of manual control point selection accuracy on automated surface matching of digital dental models. Clin Oral Investig. 22, pp.801-810. Bego. 2020. Bego Resin. [Online]. [Accessed 2 Feb 2020]. Available from: https://www.bego.com/3d-printing/materials/ Behneke, A., Burwinkel, M. and Behneke, N. 2012. Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement. Clin Oral Implants Res. 23, pp.416-23. Behneke, A., Burwinkel, M., D’Hoedt, B. and Behneke, N. 2009. Clinical assessment of the reliability of a computer-aided implant planning concept using laboratory-fabricated templates based on cone beam computed tomography. Zeitschrift fu ̈r Zahna ̈rztliche Implantologie. 25, pp.339-352. Bhargav, A., Sanjairaj, V., Rosa, V., Feng, L.W. and Fuh YH, J. 2017. Applications of additive manufacturing in dentistry: A review. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 106, pp.2058-2064. Bhattacharjee, N., Urrios, A., Kang, S. and Folch, A. 2016. The upcoming 3D-printing revolution in microfluidics. Lab on a chip. 16, pp.1720-1742. Birnbaum, N.S. and Aaronson, H.B. 2008. Dental impressions using 3D digital scanners: virtual becomes reality. Compend Contin Educ Dent. 29, pp.494, 496, 498-505. Blomstedt, P. 2013. Dental surgery in ancient Egypt. J Hist Dent. 61, pp.129-42. Bona, A.D., Borba, M., Benetti, P. and Cecchetti, D. 2007. Effect of surface treatments on the bond strength of a zirconia-reinforced ceramic to composite resin. Brazilian Oral Research. 21, pp.10-15. Bona, A.D. and Kelly, J.R. 2008. The Clinical Success Of All-Ceramic Restorations. The Journal of the American Dental Association. 139, S8-S13. Bona, A.D., Pecho, O.E. and Alessandretti, R. 2015. Zirconia as a Dental Biomaterial. Materials (Basel, Switzerland). 8, pp.4978-4991. Bothe, R.T.B., K.E.; Davenport, H.A. 1940. Reaction of bone to multiple metallic implants. Surg Gynecol Obstet. 71, pp.598-602. Braian, M. and Wennerberg, A. 2019. Trueness and precision of 5 intraoral scanners for scanning edentulous and dentate complete-arch mandibular casts: A comparative in vitro study. The Journal of Prosthetic Dentistry. 122, 129-136.e2. Brånemark, P.I. 1983. Osseointegration and its experimental background. J Prosthet Dent. 50, pp.399-410. Brenes, C., Renne, W., Tolbert, T. and Fantaski, L. 2020. Effect of Print Angulation on Surface Roughness of 3D-Printed Models. Compend Contin Educ Dent. 41, e1-e4. Brodala, N. 2009. Flapless surgery and its effect on dental implant outcomes. International Journal of Oral Maxillofacial Implants. 24, pp.118-125. Brown, G.B., Currier, G.F., Kadioglu, O. and Kierl, J.P. 2018. Accuracy of 3-dimensional printed dental models reconstructed from digital intraoral impressions. American Journal of Orthodontics and Dentofacial Orthopedics. 154, pp.733-739. Buda, M., Bratos, M. and Sorensen, J.A. 2018. Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts. The Journal of Prosthetic Dentistry. 120, pp.913-918. Camlog. 2017. Guided surgery Sleeves. [Online]. [Accessed 10 Sept 2017]. Available from: https://www.biohorizonscamlog.com/en/portfolio/implant-systems/camlog/surgery Canullo, L., Fedele, G.R., Iannello, G. and Jepsen, S. 2010. Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial. Clin Oral Implants Res. 21, pp.115-21. Carter, S.-S.D., Costa, P.F., Vaquette, C., Ivanovski, S., Hutmacher, D.W. and Malda, J. 2017. Additive Biomanufacturing: An Advanced Approach for Periodontal Tissue Regeneration. Annals of Biomedical Engineering. 45, pp.12-22. Ceyhan, J.A., Johnson, G.H. and Lepe, X. 2003. The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions. The Journal of Prosthetic Dentistry. 90, pp.143-149. Cha, M.-S., Lee, S.-W., Huh, Y.-H., Cho, L.-R. and Park, C.-J. 2017. Metal stain on monolithic zirconia restoration: A case report. The Journal of Advanced Prosthodontics. 9, pp.138-142. Chai, J., Chu, F.C., Chow, T.W., Shum, N.C. and Hui, W.W. 2006. Influence of dental status on nutritional status of geriatric patients in a convalescent and rehabilitation hospital. Int J Prosthodont. 19, pp.244-9. Chen, J., Cai, H., Ren, X., Suo, L., Pei, X. and Wan, Q. 2017. A Systematic Review of the Survival and Complication Rates of All-Ceramic Resin-Bonded Fixed Dental Prostheses. Journal of Prosthodontics. 27, pp.535-543. Chebib, N., Imamura, Y., El Osta, N., Srinivasan, M., Muller, F. and Maniewicz, S. 2022. Fit and retention of complete denture bases: Part II – conventional impressions versus digital scans: A clinical controlled crossover study. Journal of Prosthetic Dentistry. S0022-3913(22)00464-4. Advance online publication. Chen, L., Lin, W.-S., Polido, W.D., Eckert, G.J. and Morton, D. 2019. Accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates. The Journal of Prosthetic Dentistry. 122, pp.309-314. Cheng, W., Fuh, J.Y.H., Nee, A.Y.C., Wong, Y.S., Loh, H.T. and Miyazawa, T. 1995. Multi‐objective optimization of part‐building orientation in stereolithography. Rapid Prototyping Journal. 1, pp.12-23. Chockalingam, K., Jawahar, N. and Chandrasekhar, U. 2006. Influence of layer thickness on mechanical properties in stereolithography. Rapid Prototyping Journal. 12, pp.106-113. Choi, J.W. and Kim, N. 2015. Clinical application of three-dimensional printing technology in craniofacial plastic surgery. Archives of Plastic Surgery. 42, pp.267-277. Chun, J.-H., Tahk, J., Chun, Y.-S., Park, J.-M. and Kim, M. 2017. Analysis on the Accuracy of Intraoral Scanners: The Effects of Mandibular Anterior Interdental Space. Applied Sciences. 7, 719. Cochran, D.L., Hermann, J.S., Schenk, R.K., Higginbottom, F.L. and Buser, D. 1997. Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible. J Periodontol. 68, pp.186-98. Cole, D., Bencharit, S., Carrico, C.K., Arias, A. and Tüfekçi, E. 2019. Evaluation of fit for 3D-printed retainers compared with thermoform retainers. American Journal of Orthodontics and Dentofacial Orthopedics. 155, pp.592-599. Dawood, A., Marti, B.M., Sauret-Jackson, V. and Darwood, A. 2015. 3D printing in dentistry. British Dental Journal. 219, pp.521-529. Della Bona, A., Borba, M., Benetti, P., Pecho, O.E., Alessandretti, R., Mosele, J.C. and Mores, R.T. 2014. Adhesion to Dental Ceramics. Current Oral Health Reports. 1, pp.232-238. Della Bona, A., Donassollo, T.A., Demarco, F.F., Barrett, A.A. and Mecholsky, J.J. 2007. Characterization and surface treatment effects on topography of a glass-infiltrated alumina/zirconia-reinforced ceramic. Dental Materials. 23, pp.769-775. Dietrich, C.A., Ender, A., Baumgartner, S. and Mehl, A. 2017. A validation study of reconstructed rapid prototyping models produced by two technologies. The Angle Orthodontist. 87, pp.782-787. Dimitrov, D., Van Wijck, W., Schreve, K. and De Beer, N. 2006. Investigating the achievable accuracy of three-dimensional printing. Rapid Prototyping Journal. 12, pp.42-52. Dizon, J.R.C., Espera, A.H., Chen, Q. and Advincula, R.C. 2018. Mechanical characterization of 3D-printed polymers. Additive Manufacturing. 20, pp.44-67. Dong, J., Zhang, F., Wu, G.H., Zhang, W. and Yin, J. 2015. Measurement of mucosal thickness in denture-bearing area of edentulous mandible. Chin Med J (Engl). 5, pp.342-347. El Kholy K, Janner SFM, Schimmel M, Buser D. 2019. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin Implant Dent Relat Res. 21(1) pp.101-107. Elizabeth, B. 2014. 3D Printed Ceramics [Online]. Available at: http://www.materialise.com/blog/3d-printed-ceramics/ [Accessed May 7, 2019]. Ellis, J. S., Levine, A., Bedos, C., Mojon, P., Rosberger, Z., Feine, J., & Thomason, J. M. 2011. Refusal of implant supported mandibular overdentures by elderly patients. Gerodontology, 28(1), pp.62–68. Emir, F. and Ayyildiz, S. 2021. Accuracy evaluation of complete-arch models manufactured by three different 3D printing technologies: a three-dimensional analysis. Journal of Prosthodontic Research. 65, pp.365-370. Ender, A., Attin, T. and Mehl, A. 2016. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. The Journal of Prosthetic Dentistry. 115, pp.313-320. Ender, A. and Mehl, A. 2013. Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision. The Journal of Prosthetic Dentistry. 109, pp.121-128. Ericsson, I., Persson, L.G., Berglundh, T., Marinello, C.P., Lindhe, J. and Klinge, B. 1995. Different types of inflammatory reactions in peri-implant soft tissues. J Clin Periodontol. 22, pp.255-61. Ersoy, A.E., Turkyilmaz, I., Ozan, O. and McGlumphy, E.A. 2008. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. J Periodontol. 79, pp.1339-45. Esposito, M., Ekestubbe, A. and Gröndahl, K. 1993. Radiological evaluation of marginal bone loss at tooth surfaces facing single Brånemark implants. Clinical Oral Implants Research. 4, pp.151-157. Esposito, M., Hirsch, J.M., Lekholm, U. and Thomsen, P. 1998. Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology. European Journal of Oral Sciences. 106, pp.527-551. Etemad-Shahidi, Y., Qallandar, O.B., Evenden, J., Alifui-Segbaya, F. and Ahmed, K.E. 2020. Accuracy of 3-Dimensionally Printed Full-Arch Dental Models: A Systematic Review. Journal of Clinical Medicine. 9, 3357. Ettl, S., Arold, O., Vogt, P., Hybl, O., Yang, Z., Xie, W. and Häusler, G. 2009. “Flying Triangulation”: A motion-robust optical 3D sensor principle. Fringe 2009. Springer Berlin Heidelberg. Evans, C.D.J. and Chen, S.T. 2007. Esthetic outcomes of immediate implant placements. Clinical Oral Implants Research. 0, 071025001541009 Exocad. 2019. CBCT To CBCT Dual Scan Data Matching with ExoPlan Software. [Online]. [Accessed 10 May 2019]. Available from: https://exocad.com/our-products/exoplan-galway Exocad. 2020. CAD Software. [Online]. [Accessed 20 Feb 2020]. Available from: https://exocad.com/ Farjood, E., Vojdani, M., Torabi, K. & Khaledi, A.A.R., 2017. 'Marginal and internal fit of metal copings fabricated with rapid prototyping and conventional waxing', The Journal of Prosthetic Dentistry, 117, pp.164-170. Farman, A.G. & Scarfe, W.C., 2006. 'Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography', American Journal of Orthodontics and Dentofacial Orthopedics, 130, pp.257-265. Favero, C.S., English, J.D., Cozad, B.E., Wirthlin, J.O., Short, M.M. & Kasper, F.K., 2017. 'Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models', American Journal of Orthodontics and Dentofacial Orthopedics, 152, pp.557-565. Fernandes, N., Van Den Heever, J., Hoogendijk, C., Botha, S., Booysen, G. & Els, J., 2016. 'Reconstruction of an Extensive Midfacial Defect Using Additive Manufacturing Techniques', Journal of Prosthodontics, 25, pp.589-594. Fisher B, M.S., 2013. 'Simultaneous registration of multi-view range images with adaptive kernel density estimation', Institute of Mathematics and its Applications, pp.31-62. Flügge, T.V., Schlager, S., Nelson, K., Nahles, S. & Metzger, M.C., 2013. 'Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner', American Journal of Orthodontics and Dentofacial Orthopedics, 144, pp.471-478. Formlabs. 2019. 3D Printing Equipment. [Online]. [Accessed 10 Feb 2019]. Available from: https://formlabs.com/uk/ Fukazawa, S., Odaira, C. & Kondo, H., 2017. 'Investigation of accuracy and reproducibility of abutment position by intraoral scanners', Journal of Prosthodontic Research, 61, pp.450-459. Gargiulo, A.W., Wentz, F.M. & Orban, B., 1961. 'Dimensions and Relations of the Dentogingival Junction in Humans', Journal of Periodontology, 32, pp.261-267. Gebhardt, A., Schmidt, F.-M., Hötter, J.-S., Sokalla, W. & Sokalla, P., 2010. 'Additive Manufacturing by selective laser melting the realizer desktop machine and its application for the dental industry', Physics Procedia, 5, pp.543-549. George, D. & Mallery, P., 2019. IBM SPSS Statistics Processes for Mac. IBM SPSS Statistics 26 Step by Step. Routledge. Gopichander, N., Halini Kumarai, K.V. & Vasanthakumar, M., 2015. 'Effect of polyester fiber reinforcement on the mechanical properties of interim fixed partial dentures', The Saudi Dental Journal, 27, pp.194-200. Grandin, H.M., Berner, S. & Dard, M., 2012. 'A Review of Titanium Zirconium (TiZr) Alloys for Use in Endosseous Dental Implants', Materials, 5, pp.1348-1360. Greenfield, E.J., 1913. 'Implantation of artificial crown and bridge abutments', Dent Cadmos., 55. Groth, C., Kravitz, N.D., & Shirck, J.M., 2018. 'Incorporating three-dimensional printing in orthodontics', 52, 1, pp.28-33. Guess, P.C., Schultheis, S., Bonfante, E.A., Coelho, P.G., Ferencz, J.L. & Silva, N.R.F.A., 2011. 'All-Ceramic Systems: Laboratory and Clinical Performance', Dental Clinics of North America, 55, pp.333-352. Hamza, T.A., Johnston, W.M. & Schricker, S.R., 2014. 'Effect of polyhedral silsesquioxane (POSS) on the flexural strength and color of interim materials', The Journal of Prosthetic Dentistry, 112, pp.228-234. Han, T., Kundu, S., Nag, A. & Xu, Y., 2019. '3D Printed Sensors for Biomedical Applications: A Review', Sensors (Basel, Switzerland), 19, 1706. Hayden, H.C., 2015. 'Exploration of Materials Used in 3-Dimensional Printing for the Dental Industry'. Hazeveld, A., Huddleston Slater, J.J.R. & Ren, Y., 2014. 'Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques', American Journal of Orthodontics and Dentofacial Orthopedics, 145, pp.108-115. Hermann, J.S., Cochran, D.L., Nummikoski, P.V. & Buser, D., 1997. 'Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible', Journal of Periodontology, 68, pp.1117-1130. IDDA. 2018. 3d printer. [Online]. [Accessed 18 Sept 2018]. Available from: https://www.IDDA.org IDDA. 2019. 3D Models [Online]. [Accessed 11 June 2019]. Available from: https://www.IDDA.org ISO 12836. Dentistry-Digitizing devices for CAD/CAM systems for indirect dental restorations-Test methods for assessing accuracy. Geneva; Switzerland: International Standards Organization (ISO); 2015. [Accessed July 31, 2018]. Keeling, A. The Positional Change Calculator. Created at Leeds University. 2021 Lansard, M., 2018. 3D Printing For the Dental Industry. ANIWAA.Inc. Lazzara, R.J. and Porter, S.S., 2006. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent, 26, pp.9-17. Lebon, N., Tapie, L., Vennat, E. and Mawussi, B., 2015. Influence of CAD/CAM tool and material on tool wear and roughness of dental prostheses after milling. The Journal of Prosthetic Dentistry, 114, pp.236-247. Lee JH, Park JM, Kim SM, Kim MJ, Lee JH, Kim MJ. 2013 An assessment of template-guided implant surgery in terms of accuracy and related factors. J Adv Prosthodont. 5(4) pp.440-7. Lee, J.-H., Yun, J.-H., Han, J.-S., Yeo, I.-S.L. and Yoon, H.-I., 2019. Repeatability of Intraoral Scanners for Complete Arch Scan of Partially Edentulous Dentitions: An In Vitro Study. Journal of clinical medicine, 8, 1187. Ligon, S.C., Liska, R., Stampfl, J., Gurr, M. and Mülhaupt, R., 2017. Polymers for 3D Printing and Customized Additive Manufacturing. Chemical reviews, 117, pp.10212-10290. Lim, J.-H., Park, J.-M., Kim, M., Heo, S.-J. and Myung, J.-Y., 2018. Comparison of digital intraoral scanner reproducibility and image trueness considering repetitive experience. The Journal of Prosthetic Dentistry, 119, pp.225-232. Loflin, W.A., English, J.D., Borders, C., Harris, L.M., Moon, A., Holland, J.N. and Kasper, F.K., 2019. Effect of print layer height on the assessment of 3D-printed models. American Journal of Orthodontics and Dentofacial Orthopedics, 156, pp.283-289. Ludlow, J.B., Laster, W.S., See, M., Bailey, L.T.J. and Hershey, H.G., 2007. Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics, 103, pp.534-542. Lund, H., Gröndahl, K. and Gröndahl, H.-G., 2010. Cone Beam Computed Tomography for Assessment of Root Length and Marginal Bone Level during Orthodontic Treatment. The Angle Orthodontist, 80, pp.466-473. Mack, A., 1971. Full Dentures., 11. Mahamood, S., Khader, M.A. and Ali, H., 2016. Applications of 3-D printing in orthodontics: a review. International Journal of Scientific Study, 3, pp.267-270. Mandelaris, G.R., 2010. Computer-guided implant dentistry for precise implant placement: combining specialized stereolithographically generated drilling guides and surgical implant instrumentation. The International journal of periodontics & restorative dentistry, 30, 275. Mangano, F., Gandolfi, A., Luongo, G. and Logozzo, S., 2017. Intraoral scanners in dentistry: a review of the current literature. BMC oral health, 17, 149-149. Mangano, F.G., Admakin, O., Bonacina, M., Biaggini, F., Farronato, D. and Lerner, H., 2020. Accuracy of 6 Desktop 3D Printers in Dentistry: A Comparative In Vitro Study. Eur J Prosthodont Restor Dent, 28, pp.75-85. Mangano, F.G., Hauschild, U., Veronesi, G., Imburgia, M., Mangano, C. and Admakin, O., 2019. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. BMC oral health, 19, 101-101. Mangano, F.G., Veronesi, G., Hauschild, U., Mijiritsky, E. and Mangano, C., 2016. Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study. PloS one, 11, e0163107-e0163107. Mansour, S., Gilbert, M. and Hague, R., 2007. A study of the impact of short-term ageing on the mechanical properties of a stereolithography resin. Materials Science and Engineering: A, 447, pp.277-284. Mao, Z., Park, K., Lee, K. and Li, X., 2013. Robust surface reconstruction of teeth from raw pointsets. International Journal for Numerical Methods in Biomedical Engineering, 30, pp.382-396. McGill, N., 2002. The McGill Consensus Statement on Overdentures: Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology, 19, pp.3-4. Medina-Sotomayor, P., Pascual-Moscardo, A. and Camps A, I., 2019. Accuracy of 4 digital scanning systems on prepared teeth digitally isolated from a complete dental arch. The Journal of Prosthetic Dentistry, 121, pp.811-820. Menini, M., Setti, P., Pera, F., Pera, P. and Pesce, P., 2017. Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure. Clinical Oral Investigations, 22, pp.1253-1262. Misch, C.E., 1990. Density of bone: Effect on treatment plans, surgical approach, healing, and progressive bone loading. International Journal of Oral Implantology, 6(2), pp.23-31. Miyazaki, T., Nakamura, T., Matsumura, H., Ban, S. and Kobayashi, T., 2013. Current status of zirconia restoration. Journal of Prosthodontic Research, 57, pp.236-261. Moörmann, W.H., 2006. The evolution of the CEREC system. The Journal of the American Dental Association, 137, pp.7S-13S. Murray, J.J., 2011. Adult Dental Health Surveys: 40 years on. British Dental Journal, 211, pp.407-408. N. Turner, B., Strong, R. and A. Gold, S., 2014. A review of melt extrusion additive manufacturing processes: I. Process design and modeling. Rapid Prototyping Journal, 20, pp.192-204. Nagy, Z.A., Simon, B., Tóth, Z. and Vág, J., 2018. Evaluating the efficiency of the Dental Teacher system as a digital preclinical teaching tool. European Journal of Dental Education, 22, e619-e623. Nasef, A.A., El-Beialy, A.R., Eid, F.H.K. and Mostafa, Y.A., 2017. Accuracy of Orthodontic 3D Printed Retainers versus Thermoformed Retainers. Open Journal of Medical Imaging, 07, pp.169-179. Nayar, S., Bhuminathan, S. and Bhat, W.M., 2015a. Rapid prototyping and stereolithography in dentistry. Journal of pharmacy & bioallied sciences, 7, S216-S219. Nayar, S., Ganesh, R. and Santhosh, S., 2015b. Fiber reinforced composites in prosthodontics - A systematic review. Journal of pharmacy & bioallied sciences, 7, S220-S222. Nedelcu, R., Olsson, P., Nyström, I., Rydén, J. and Thor, A., 2018. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method. Journal of Dentistry, 69, pp.110-118. Nedelcu RG, P.A., 2014. Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis. J Prosthet Dent, 112, pp.1461-1471. Nedelcu, R.G. and Persson, A.S.K., 2014. Scanning accuracy and precision in 4 intraoral scanners: An in vitro comparison based on 3-dimensional analysis. The Journal of Prosthetic Dentistry, 112, pp.1461-1471. Ng, J., Ruse, D. and Wyatt, C., 2014. A comparison of the marginal fit of crowns fabricated with digital and conventional methods. The Journal of Prosthetic Dentistry, 112, pp.555-560. Nickenig, H.-J. and Eitner, S., 2007. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates. Journal of Cranio-Maxillofacial Surgery, 35, pp.207-211. Oba, Y., Koizumi, H., Nakayama, D., Ishii, T., Akazawa, N. and Matsumura, H., 2014. Effect of silane and phosphate primers on the adhesive performance of atri-n-butylborane initiated luting agent bonded to zirconia. Dental Materials Journal, 33, pp.226-232. Oberoi, G., Nitsch, S., Edelmayer, M., Janjić, K., Müller, A.S. and Agis, H., 2018. 3D Printing-Encompassing the Facets of Dentistry. Frontiers in bioengineering and biotechnology, 6, 172-172. Oh KC, Shim JS, Park JM. 2021 In Vitro Comparison between Metal Sleeve-Free and Metal Sleeve-Incorporated 3D-Printed Computer-Assisted Implant Surgical Guides. Materials (Basel). 29;14(3) pp.615. Osstem. 2017. Guided surgery Kit. [Online]. [Accessed 10 Sept 2017]. Available from: https://www.osstemuk.com/surgery-kits/ Ottemer, X. and Colton, J.S., 2002. Effects of aging on epoxy‐based rapid tooling materials. Rapid Prototyping Journal, 8, pp.215-223. Park, G.-H., Son, K. & Lee, K.-B. 2019. Feasibility of using an intraoral scanner for a complete-arch digital scan. The Journal of Prosthetic Dentistry, 121, pp.803-810. Park, J.-M., Ahn, J.-S., Cha, H.-S. & Lee, J.-H. 2018. Wear Resistance of 3D Printing Resin Material Opposing Zirconia and Metal Antagonists. Materials (Basel, Switzerland), 11, 1043. Park, M.-E. & Shin, S.-Y. 2018. Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers. The Journal of Prosthetic Dentistry, 119, pp.861.e1-861.e7. Park, S., Kang, H.C., Lee, J., Shin, J. & Shin, Y.G. 2015. An enhanced method for registration of dental surfaces partially scanned by a 3D dental laser scanning. Computer Methods and Programs in Biomedicine, 118, pp.11-22. Patras, M., Naka, O., Doukoudakis, S. & Pissiotis, A. 2011. Management of Provisional Restorations' Deficiencies: A Literature Review. Journal of Esthetic and Restorative Dentistry, 24, pp.26-38. Patzelt, S.B.M., Bishti, S., Stampf, S. & Att, W. 2014. Accuracy of computer-aided design/computer-aided manufacturing–generated dental casts based on intraoral scanner data. The Journal of the American Dental Association, 145, pp.1133-1140. Patzelt, S.B.M., Emmanoulidi, A., Stampf, S., Strub, J.R. & Att, W. 2013a. Accuracy of full-arch scans using intraoral scanners. Clinical Oral Investigations, 18, pp.1687-1694. Patzelt, S.B.M., Vonau, S., Stampf, S. & Att, W. 2013b. Assessing the feasibility and accuracy of digitizing edentulous jaws. The Journal of the American Dental Association, 144, pp.914-920. Pauwels, R., Araki, K., Siewerdsen, J.H. & Thongvigitmanee, S.S. 2015. Technical aspects of dental CBCT: state of the art. Dentomaxillofacial Radiology, 44, 20140224. Peñate, L., Basilio, J., Roig, M. & Mercadé, M. 2015. Comparative study of interim materials for direct fixed dental prostheses and their fabrication with CAD/CAM technique. The Journal of Prosthetic Dentistry, 114, pp.248-253. Pesce, P., Pera, F., Setti, P. & Menini, M. 2018. Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation. The International Journal of Prosthodontics, 31, pp.171-175. Piedra Cascón, W., Parra Nuñez, A., Charlén Díez, I. & Revilla-León, M. 2018. Laboratory workflow to obtain long-term injected resin composite interim restorations from an additive manufactured esthetic diagnostic template. Journal of Esthetic and Restorative Dentistry, 31, pp.13-19. Pinsky, H.M., Dyda, S., Pinsky, R.W., Misch, K.A. & Sarment, D.P. 2006. Accuracy of three-dimensional measurements using cone-beam CT. Dentomaxillofacial Radiology, 35, pp.410-416. Prasad, S., Kader, N.A., Sujatha, G., Raj, T. & Patil, S. 2018. 3D printing in dentistry. Journal of 3D Printing in Medicine, 2, pp.89-91. PSM. 2018. Benefit System. [Online]. [Accessed 18 Sept 2018]. Available from: https://psm-medical.com/ Puebla, K., Arcaute, K., Quintana, R. & Wicker, R.B. 2012. Effects of environmental conditions, aging, and build orientations on the mechanical properties of ASTM type I specimens manufactured via stereolithography. Rapid Prototyping Journal, 18, pp.374-388. Rayyan, M.M., Aboushelib, M., Sayed, N.M., Ibrahim, A. & Jimbo, R. 2015. Comparison of interim restorations fabricated by CAD/CAM with those fabricated manually. The Journal of Prosthetic Dentistry, 114, pp.414-419. Rech-Ortega, C., Fernández-Estevan, L., Solá-Ruíz, M.F., Agustín-Panadero, R. & Labaig-Rueda, C. 2019. Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material versus intraoral scanner. Medicina Oral, Patologia Oral y Cirugia Bucal, 24, pp.e89-e95. Rehmann, P., Sichwardt, V. & Wöstmann, B. 2017. Intraoral Scanning Systems: Need for Maintenance. The International Journal of Prosthodontics, pp.27-29. Revilla-León, M., Gonzalez-Martín, Ó., Pérez López, J., Sánchez-Rubio, J.L. & Özcan, M. 2017. Position Accuracy of Implant Analogs on 3D Printed Polymer versus Conventional Dental Stone Casts Measured Using a Coordinate Measuring Machine. Journal of Prosthodontics, 27, pp.560-567. Revilla-León, M., Meyers, M.J., Zandinejad, A. & Özcan, M. 2018. A review on chemical composition, mechanical properties, and manufacturing work flow of additively manufactured current polymers for interim dental restorations. Journal of Esthetic and Restorative Dentistry, 31, pp.51-57. Revilla-León, M. & Özcan, M. 2017. Additive Manufacturing Technologies Used for 3D Metal Printing in Dentistry. Current Oral Health Reports, 4, pp.201-208. Reza, M. 2007. Nanomaterials and Nanosystems for Biomedical Applications. SpringerLink: Springer e-Books. Richert, R., Goujat, A., Venet, L., Viguie, G., Viennot, S., Robinson, P., Farges, J.-C., Fages, M. & Ducret, M. 2017. Intraoral Scanner Technologies: A Review to Make a Successful Impression. Journal of Healthcare Engineering, 2017, pp.8427595-8427595. Ritter, L., Reiz, S.D., Rothamel, D., Dreiseidler, T., Karapetian, V., Scheer, M. & Zöller, J.E. 2011. Registration accuracy of three-dimensional surface and cone beam computed tomography data for virtual implant planning. Clinical Oral Implants Research, 23, pp.447-452. Rodríguez-Ciurana, X., Vela-Nebot, X., Segalà-Torres, M., Calvo-Guirado, J.L., Cambra, J., Méndez-Blanco, V. & Tarnow, D.P. 2009. The effect of interimplant distance on the height of the interimplant bone crest when using platform-switched implants. Int J Periodontics Restorative Dent, 29, pp.141-51. Rovelo, P. 2016. Additive Manufacturing in the Medical and Dental Technology Industries. Available: https://3dprintingindustry.com/news/additive-manufacturing-medical-dental-technology-industries-80348/ [Accessed May 9, 2019]. Sakornwimon, N. & Leevailoj, C. 2017. Clinical marginal fit of zirconia crowns and patients’ preferences for impression techniques using intraoral digital scanner versus polyvinyl siloxane material. The Journal of Prosthetic Dentistry, 118, pp.386-391. Sason, G.K., Mistry, G., Tabassum, R. & Shetty, O. 2018. A comparative evaluation of intraoral and extraoral digital impressions: An in vivo study. Journal of Indian Prosthodontic Society, 18, pp.108-116. Schneider, D., Marquardt, P., Zwahlen, M. & Jung, R.E. 2009. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clinical Oral Implants Research, 20, pp.73-86. Schnutenhaus, S., Gröller, S., Luthardt, R.G. & Rudolph, H. 2018. Accuracy of the match between cone beam computed tomography and model scan data in template-guided implant planning: A prospective controlled clinical study. Clinical Implant Dentistry and Related Research, 20, pp.541-549. Schulze, R., Heil, U., Gross, D., Bruellmann, D. D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. 2011) Artefacts in CBCT: a review. Dento maxillo facial radiology. 40(5), pp.265–273. Schweiger, J., Edelhoff, D., & Güth, J. F. 2021. 3D Printing in Digital Prosthetic Dentistry: An Overview of Recent Developments in Additive Manufacturing. Journal of clinical medicine, 10, pp.9 Scopigno, R., Cignoni, P., Pietroni, N., Callieri, M. & Dellepiane, M. 2015. Digital Fabrication Techniques for Cultural Heritage: A Survey. Computer Graphics Forum, 36, pp.6-21. Siciliano, B. and Khatib, O. (eds.) 2016. Springer Handbook of Robotics. Springer. Sirona, D. Ineos X5 Lab Scanner Information [Online]. Available: https://www.dentsplysirona.com/en/explore/lab/cad-cam-equipment-dental-lab/scan.html [Accessed]. Spray, J.R., Black, C.G., Morris, H.F. & Ochi, S. 2000. The Influence of Bone Thickness on Facial Marginal Bone Response: Stage 1 Placement Through Stage 2 Uncovering. Annals of Periodontology, 5, pp.119-128. Stansbury, J.W. & Idacavage, M.J. 2016. 3D printing with polymers: Challenges among expanding options and opportunities. Dental Materials, 32, pp.54-64. Steele, J.G., Treasure, E.T., O'Sullivan, I., Morris, J. & Murray, J.J. 2012. Adult Dental Health Survey 2009: transformations in British oral health 1968–2009. British Dental Journal, 213, pp.523-527. Stewart, M. & Bagby, M. 2018. Clinical aspects of dental materials: Theory, practice, and cases. Wolters Kluwer Health/Lippincott Williams & Wilkins. Stratasys. 2017. Stratasys and Siemens to improve 3D printing volume production. Reinforced Plastics, 61, pp.10-11. Straumann. 2017. Guided surgery Spoons. [Online]. [Accessed 10 Sept 2017]. Available from: https://www.straumann.com/gb/en/dental-professionals/products-and-solutions/guided-surgery.html Sweeney, S., Smith, D.K. & Messersmith, M. 2015. Comparison of 5 types of interocclusal recording materials on the accuracy of articulation of digital models. American Journal of Orthodontics and Dentofacial Orthopedics, 148, pp.245-252. Swissmeda. 2017. User Guide for SMOP Pre-Post Implant position comparison Version 2.12. Switzerland. Sykes, L. 2004. Applications of rapid prototyping technology in maxillofacial prosthetics. International Journal of Prosthodontics, 14. Szeliski, R. 2010. Computer Vision: Algorithms and Applications. Springer. Tahayeri, A., Morgan, M., Fugolin, A.P., Bompolaki, D., Athirasala, A., Pfeifer, C.S., Ferracane, J.L. & Bertassoni, L.E. 2018. 3D printed versus conventionally cured provisional crown and bridge dental materials. Dental Materials: Official Publication of the Academy of Dental Materials, 34, pp.192-200. Tapie, L., Lebon, N., Mawussi, B., Fron-Chabouis, H., Duret, F. & Attal, J.P. 2015. Understanding dental CAD/CAM for restorations- accuracy from a mechanical engineering viewpoint. Int J Comput Dent, 18, pp.334-367. Tarnow, D.P., Cho, S.C. & Wallace, S.S. 2000. The Effect of Inter-Implant Distance on the Height of Inter-Implant Bone Crest. Journal of Periodontology, 71, pp.546-549. Teughels, W., Merheb, J. & Quirynen, M. 2009. Critical horizontal dimensions of interproximal and buccal bone around implants for optimal aesthetic outcomes: a systematic review. Clinical Oral Implants Research, 20, pp.134-145. Thomason, J.M., Feine, J., Exley, C., Moynihan, P., Müller, F., Naert, I., Ellis, J.S., Barclay, C., Butterworth, C., Scott, B., Lynch, C., Stewardson, D., Smith, P., Welfare, R., Hyde, T., McAndrew, R., Fenlon, M., Barclay, S. & Barker, D. 2009. The York consensus statement on implant-supported overdentures. European Journal of Prosthodontic and Restorative Dentistry. Ting-Shu, S. & Jian, S. 2014. Intraoral Digital Impression Technique: A Review. Journal of Prosthodontics, 24, pp.313-321. Torabi, K., Farjood, E. & Hamedani, S. 2015. Rapid Prototyping Technologies and their Applications in Prosthodontics, a Review of Literature. Journal of Dentistry (Shiraz, Iran), 16, pp.1-9. Tsakos, G., Herrick, K., Sheiham, A. & Watt, R.G. 2010. Edentulism and fruit and vegetable intake in low-income adults. J Dent Res., May, pp.462-467. Uhm, S.-H., Kim, J.-H., Jiang, H.B., Woo, C.-W., Chang, M., Kim, K.-N., Bae, J.-M. & Oh, S. 2017. Evaluation of the accuracy and precision of four intraoral scanners with 70% reduced inlay and four-unit bridge models of international standard. Dental Materials Journal, 36, pp.27-34. Urrios, A., Parra-Cabrera, C., Bhattacharjee, N., Gonzalez-Suarez, A.M., Rigat-Brugarolas, L.G., Nallapatti, U., Samitier, J., DeForest, C.A., Posas, F., Garcia-Cordero, J.L. & Folch, A. 2016. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab on a Chip, 16, pp.2287-2294. Vaidyanathan, T.K., Vaidyanathan, J. & Arghavani, D. 2016. Elastic, viscoelastic and viscoplastic contributions to compliance during deformation under stress in prosthodontic temporization materials. Acta Biomaterialia Odontologica Scandinavica, 2, pp.108-117. Van Assche, N., Vercruyssen, M., Coucke, W., Teughels, W., Jacobs, R. & Quirynen, M. 2012. Accuracy of computer-aided implant placement. Clinical Oral Implants Research, 23, pp.112-123. Van Steenberghe, D. 2005. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clinical Implant Dentistry and Related Research, 7, pp.111-120. Vos, T., Flaxman, A.D., Naghavi, M., et al. 2012. Years lived with disability (YLDs) for 1160 sequelae of 289 diseases and injuries 1990-2010: a systematic analysis for the Global Burden of Disease Study 2010 [published correction appears in Lancet. 2013 Feb 23;381(9867):628. AlMazroa, Mohammad A [added]; Memish, Ziad A [added]]. Lancet, 380(9859), pp.2163-2196 Witkowski, S., Komine, F. & Gerds, T. 2006. Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques. The Journal of Prosthetic Dentistry, 96, pp.47-52."],"dcterms:accessrights":["public"],"dc:title":["Accuracy of a New Method To Combine Digital Impressions With CBCT Scans Of The Edentulous Mandible"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000233297782"]},"updated_at":"2026-11-18T23:24:33Z"}