{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:33871"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:33871","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Mechanical Design Optimisation of a Tibial Insert for use in Instrumented Total Knee Replacement","abstract":"This PhD research has presented guidelines on how to design, manufacture, and test a smart knee implant. The aim of this PhD research was to investigate how to modify a conventional tibial insert design to incorporate sensors and electronic components whilst ensuring patient safety. Several manufacturing methods were developed to address manufacturing and assembling challenges. Computational and experimental studies were carried out to analyse the structural strength, wear performance, and safety of a modified tibial insert. Additional experimental studies were performed to illustrate the feasibility and practical applications for making measurements with embedded sensors. Previous studies on instrumented tibial inserts did not address manufacturing limitations nor safety concerns.","abstract_html":"This PhD research has presented guidelines on how to design, manufacture, and test a smart knee implant. The aim of this PhD research was to investigate how to modify a conventional tibial insert design to incorporate sensors and electronic components whilst ensuring patient safety. Several manufacturing methods were developed to address manufacturing and assembling challenges. Computational and experimental studies were carried out to analyse the structural strength, wear performance, and safety of a modified tibial insert. Additional experimental studies were performed to illustrate the feasibility and practical applications for making measurements with embedded sensors. Previous studies on instrumented tibial inserts did not address manufacturing limitations nor safety concerns.","abstract_has_math":false,"creators":["Kelmers, Edgars"],"institution":"University of Leeds","degree_name":"Integrated Ph.D and Master","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Pandit, Hemant","van Duren, Bernard H.","Jennings, Louise M.","Wilcox, Ruth K."],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-11","date_published":"2023-11","updated_at":"2026-11-18T23:24:33Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/33871/3/Video%202%2C%20CPRESS%2C%20modified%20tibial%20insert%20with%20a%20hole%2C%20GMK%20Primary%20size%203%20left.avi"],"render_values":[{"text":"https://etheses.whiterose.ac.uk/id/eprint/33871/3/Video%202%2C%20CPRESS%2C%20modified%20tibial%20insert%20with%20a%20hole%2C%20GMK%20Primary%20size%203%20left.avi","href":"https://etheses.whiterose.ac.uk/id/eprint/33871/3/Video%202%2C%20CPRESS%2C%20modified%20tibial%20insert%20with%20a%20hole%2C%20GMK%20Primary%20size%203%20left.avi","code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/L014823/1"],"render_values":[{"text":"EP/L014823/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000251334700"],"render_values":[{"text":"0000-0002-5133-4700","href":"https://orcid.org/0000-0002-5133-4700","code":true}]}]},"links":{"outbound_url":"https://etheses.whiterose.ac.uk/id/eprint/33871/2/Video%201%2C%20CPRESS%2C%20original%20unmodified%20tibial%20insert%2C%20GMK%20Primary%20size%203%20left.avi","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://etheses.whiterose.ac.uk/id/eprint/33871/2/Video%201%2C%20CPRESS%2C%20original%20unmodified%20tibial%20insert%2C%20GMK%20Primary%20size%203%20left.avi","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":"https://etheses.whiterose.ac.uk/id/eprint/33871/1/Edgars%20Kelmers%2C%20PhD%20thesis%20Nov-2023%2C%20Mechanical%20Design%20Optimisation%20of%20a%20Tibial%20Insert%20for%20use%20in%20Instrumented%20Total%20Knee%20Replacement.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A33871","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pandit, Hemant","van Duren, Bernard H.","Jennings, Louise M.","Wilcox, Ruth K."]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Engineering and Physical Sciences Research Council (EPSRC)"]},{"key":"dc:creator","label":"Author","values":["Kelmers, Edgars"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000251334700"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-11"]},{"key":"dc:date.issued","label":"Date","values":["2023-11"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/33871/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. Human anatomy planes. National Cancer Institute. 2. Losina E, Thornhill TS, Rome BN, Wright J, Katz JN. The dramatic increase in total knee replacement utilization rates in the United States cannot be fully explained by growth in population size and the obesity epidemic. JBJS. 2012;94(3):201-207. doi: 10.2106/JBJS.J.01958. PubMed PMID: 22298051. 3. NJR. National Joint Registry for England, Wales, Northern Ireland and the Isle of Man: 15th Annual Report. 2018. 4. Inacio MCS, Paxton EW, Graves SE, Namba RS, Nemes S. Projected increase in total knee arthroplasty in the United States – an alternative projection model. Osteoarthr Cartil. 2017;25(11):1797-1803. doi: https://doi.org/10.1016/j.joca.2017.07.022. 5. Kurtz SM, Ong KL, Lau E, Widmer M, Maravic M, Gómez-Barrena E, et al. International survey of primary and revision total knee replacement. Int Orthop. 2011;35(12):1783-1789. doi: https://doi.org/10.1007/s00264-011-1235-5. Epub 2011/03/15. PubMed PMID: 21404023. 6. Schwartz AM, Farley KX, Guild GN, Bradbury TL. Projections and Epidemiology of Revision Hip and Knee Arthroplasty in the United States to 2030. The Journal of Arthroplasty. 2020;35(6, Supplement):S79-S85. doi: https://doi.org/10.1016/j.arth.2020.02.030. 7. Evans JT, Walker RW, Evans JP, Blom AW, Sayers A, Whitehouse MR. How long does a knee replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up. The Lancet. 2019;393(10172):655-663. doi: https://doi.org/10.1016/S0140-6736(18)32531-5. 8. Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). Hip, Knee & Shoulder Arthroplasty: 2019 Annual Report. Adelaide: AOA, 2019. 9. Torrão JND, dos Santos MPS, Ferreira JAF. Instrumented knee joint implants: innovations and promising concepts. Expert Review of Medical Devices. 2015;12(5):571-584. doi: https://doi.org/10.1586/17434440.2015.1068114. 10. Crescini D, Sardini E, Serpelloni M, . An Autonomous Sensor for Force Measurements in Human Knee Implants. Procedia Chem. 2009;1(1):718-721. doi: https://doi.org/10.1016/j.proche.2009.07.179. 11. Crescini D, Sardini E, Serpelloni M, . Design and test of an autonomous sensor for force measurements in human knee implants. Sens Actuator A Phys. 2011;166(1):1-8. doi: https://doi.org/10.1016/j.sna.2010.12.010. 12. Simoncini M. Design and integration of an instrumented knee prosthesis. PhD thesis 2014. 13. Clarke HD, Scott WN, Insall JN, Pedersen HB, Math KR, Vigorita VJ, et al. Anatomy. Insall & Scott Surgery of the Knee, 5th edition, chapter 1. Philadelphia: Elsevier Health Sciences; 2012. 14. Taylor WR, Schütz P, Bergmann G, List R, Postolka B, Hitz M, et al. A comprehensive assessment of the musculoskeletal system: The CAMS-Knee data set. Journal of Biomechanics. 2017;65:32-39. doi: https://doi.org/10.1016/j.jbiomech.2017.09.022. 15. Halder A, Kutzner I, Graichen F, Heinlein B, Beier A, Bergmann G. Influence of Limb Alignment on Mediolateral Loading in Total Knee Replacement: In Vivo Measurements in Five Patients. JBJS. 2012;94(11):1023-1029. doi: 10.2106/jbjs.K.00927. PubMed PMID: 00004623-201206060-00007. 16. Chen Z, Jin Z. Prediction of in-vivo kinematics and contact track of total knee arthroplasty during walking. Biosurface and Biotribology. 2016;2(3):86-94. doi: https://doi.org/10.1016/j.bsbt.2016.08.002. 17. Popoola OO, Yao JQ, Johnson TS, Blanchard CR. Wear, delamination, and fatigue resistance of melt-annealed highly crosslinked UHMWPE cruciate-retaining knee inserts under activities of daily living. Journal of Orthopaedic Research. 2010;28(9):1120-1126. doi: 10.1002/jor.21104. 18. Schwiesau J, Fritz B, Kutzner I, Bergmann G, Grupp TM. CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities. Biomed Res Int. 2014;2014:567374-567374. doi: 10.1155/2014/567374. Epub 2014/11/20. PubMed PMID: 25506594. 19. Grupp TM, Fritz B, Kutzner I, Schilling C, Bergmann G, Schwiesau J. Vitamin E stabilised polyethylene for total knee arthroplasty evaluated under highly demanding activities wear simulation. Acta Biomaterialia. 2017;48:415-422. doi: https://doi.org/10.1016/j.actbio.2016.10.031. 20. Saxby DJ, Modenese L, Bryant AL, Gerus P, Killen B, Fortin K, et al. Tibiofemoral contact forces during walking, running and sidestepping. Gait & Posture. 2016;49:78-85. doi: https://doi.org/10.1016/j.gaitpost.2016.06.014. 21. Bergmann G, Bender A, Graichen F, Dymke J, Rohlmann A, Trepczynski A, et al. Standardized loads acting in knee implants. PLoS One. 2014;9(1):e86035-e86035. doi: 10.1371/journal.pone.0086035. PubMed PMID: 24465856. 22. Messier SP, Pater M, Beavers DP, Legault C, Loeser RF, Hunter DJ, et al. Influences of alignment and obesity on knee joint loading in osteoarthritic gait. Osteoarthr Cartil. 2014;22(7):912-917. doi: 10.1016/j.joca.2014.05.013. Epub 2014/05/21. PubMed PMID: 24857973. 23. Kumar D, Manal KT, Rudolph KS. Knee joint loading during gait in healthy controls and individuals with knee osteoarthritis. Osteoarthr Cartil. 2013;21(2):298-305. doi: https://doi.org/10.1016/j.joca.2012.11.008. 24. Worsley P, Stokes M, Barrett D, Taylor M. Joint loading asymmetries in knee replacement patients observed both pre- and six months post-operation. Clinical Biomechanics. 2013;28(8):892-897. doi: https://doi.org/10.1016/j.clinbiomech.2013.07.014. 25. Kutzner I, Küther S, Heinlein B, Dymke J, Bender A, Halder AM, et al. The effect of valgus braces on medial compartment load of the knee joint – in vivo load measurements in three subjects. Journal of Biomechanics. 2011;44(7):1354-1360. doi: https://doi.org/10.1016/j.jbiomech.2011.01.014. 26. Lundberg HJ, Ngai V, Wimmer MA. Comparison of ISO Standard and TKR patient axial force profiles during the stance phase of gait. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2012;226(3):227-234. doi: 10.1177/0954411911431650. PubMed PMID: 22558837. 27. Winby CR, Lloyd DG, Besier TF, Kirk TB. Muscle and external load contribution to knee joint contact loads during normal gait. Journal of Biomechanics. 2009;42(14):2294-2300. doi: https://doi.org/10.1016/j.jbiomech.2009.06.019. 28. D'Lima DD, Steklov N, Patil S, Colwell CW, Jr. The Mark Coventry Award: in vivo knee forces during recreation and exercise after knee arthroplasty. Clin Orthop Relat R. 2008;466(11):2605-2611. doi: https://doi.org/10.1007/s11999-008-0345-x. Epub 2008/06/19. PubMed PMID: 18563502. 29. Messier SP, Gutekunst DJ, Davis C, DeVita P. Weight loss reduces knee-joint loads in overweight and obese older adults with knee osteoarthritis. Arthritis & Rheumatism. 2005;52(7):2026-2032. doi: 10.1002/art.21139. 30. Kurtz SM. 8 - The Origins and Adaptations of UHMWPE for Knee Replacements. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 106-122. 31. Kurtz SM, Zagorski M. 3 - Packaging and Sterilization of UHMWPE. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 21-32. 32. Kaivosoja E, Tiainen VM, Takakubo Y, Rajchel B, Sobiecki J, Konttinen YT, et al. 7 - Materials used for hip and knee implants. In: Affatato S, editor. Wear of Orthopaedic Implants and Artificial Joints: Woodhead Publishing; 2013. p. 178-218. 33. Medacta. GMK Primary [accessed 2020 May 15]. Available from: https://www.medacta.com/EN/gmk-primary. 34. Kurtz SM. 9 - The Clinical Performance of UHMWPE in Knee Replacements. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 123-144. 35. ISO. ISO 16087:2013 Implants for surgery — Roentgen stereophotogrammetric analysis for the assessment of migration of orthopaedic implants. 36. van IJsseldijk EA, Valstar ER, Stoel BC, de Ridder R, Nelissen RGHH, Kaptein BL. Measuring polyethylene wear in total knee arthroplasty by RSA: Differences between weight-bearing and non-weight-bearing positioning. Journal of Orthopaedic Research. 2014;32(4):613-617. doi: https://doi.org/10.1002/jor.22579. 37. Losina E, Katz JN. Total knee arthroplasty on the rise in younger patients: are we sure that past performance will guarantee future success? Arthritis Rheum. 2012;64(2):339-341. doi: 10.1002/art.33371. PubMed PMID: 22252374. 38. Nam D, Nunley RM, Barrack RL. Patient dissatisfaction following total knee replacement. BJJ. 2014;96-B(11_Supple_A):96-100. doi: https://doi.org/10.1302/0301-620x.96b11.34152. 39. Gunaratne R, Pratt DN, Banda J, Fick DP, Khan RJK, Robertson BW. Patient Dissatisfaction Following Total Knee Arthroplasty: A Systematic Review of the Literature. The Journal of Arthroplasty. 2017;32(12):3854-3860. doi: https://doi.org/10.1016/j.arth.2017.07.021. 40. Uvehammer J, Kärrholm J, Brandsson S, Herberts P, Carlsson L, Karlsson J, et al. In vivo kinematics of total knee arthroplasty: Flat compared with concave tibial joint surface. Journal of Orthopaedic Research. 2000;18(6):856-864. doi: 10.1002/jor.1100180603. 41. Ardestani MM, Moazen M, Jin Z. Contribution of geometric design parameters to knee implant performance: Conflicting impact of conformity on kinematics and contact mechanics. The Knee. 2015;22(3):217-224. doi: https://doi.org/10.1016/j.knee.2015.02.011. 42. Koh Y-G, Nam J-H, Kang K-T. Effect of geometric variations on tibiofemoral surface and post-cam design of normal knee kinematics restoration. Journal of Experimental Orthopaedics. 2018;5(1):53. doi: 10.1186/s40634-018-0167-z. 43. Li Y, Wang S, Wang Y, Yang M. Does Kinematic Alignment Improve Short-Term Functional Outcomes after Total Knee Arthroplasty Compared with Mechanical Alignment? A Systematic Review and Meta-analysis. J Knee Surg. 2018;31(01):078-086. doi: 10.1055/s-0037-1602136. Epub 01.05.2017. 44. Chen C, Li R. Cementless versus cemented total knee arthroplasty in young patients: a meta-analysis of randomized controlled trials. J Orthop Surg Res. 2019;14(1):262-262. doi: 10.1186/s13018-019-1293-8. PubMed PMID: 31426816. 45. Longo UG, Ciuffreda M, Mannering N, D'Andrea V, Cimmino M, Denaro V. Patellar Resurfacing in Total Knee Arthroplasty: Systematic Review and Meta-Analysis. The Journal of Arthroplasty. 2018;33(2):620-632. doi: 10.1016/j.arth.2017.08.041. 46. Verra WC, Boom LGHvd, Jacobs WCH, Schoones JW, Wymenga AB, Nelissen RGHH. Similar outcome after retention or sacrifice of the posterior cruciate ligament in total knee arthroplasty. Acta Orthop. 2015;86(2):195-201. doi: 10.3109/17453674.2014.973329. Epub 2014/10/17. PubMed PMID: 25323799. 47. Young T, Dowsey MM, Pandy M, Choong PF. A Systematic Review of Clinical Functional Outcomes After Medial Stabilized Versus Non-Medial Stabilized Total Knee Joint Replacement. Front Surg. 2018;5:25-25. doi: 10.3389/fsurg.2018.00025. PubMed PMID: 29696144. 48. Kaufman KR, Kovacevic N, Irby SE, Colwell CW. Instrumented implant for measuring tibiofemoral forces. Journal of Biomechanics. 1996;29(5):667-671. doi: https://doi.org/10.1016/0021-9290(95)00124-7. 49. ASTM F3141-17a, Standard Guide for Total Knee Replacement Loading Profiles. West Conshohocken, PA: ASTM International; 2017. 50. O’Connor C, Kiourti A. Wireless Sensors for Smart Orthopedic Implants. Journal of Bio- and Tribo-Corrosion. 2017;3(2):20. doi: https://doi.org/10.1007/s40735-017-0078-z. 51. Karipott SS, Veetil PM, Nelson BD, Guldberg RE, Ong KG. An Embedded Wireless Temperature Sensor for Orthopedic Implants. IEEE Sensors Journal. 2018;18(3):1265-1272. doi: https://doi.org/10.1109/JSEN.2017.2780226. 52. Pritchett JW. Heat Generated by Knee Prostheses. Clinical Orthopaedics and Related Research®. 2006;442:195-198. doi: https://doi.org/10.1097/01.blo.0000183739.50869.bb. PubMed PMID: 00003086-200601000-00031. 53. Liu X, Berger JL, Ogirala A, Mickle MH. A Touch Probe Method of Operating an Implantable RFID Tag for Orthopedic Implant Identification. IEEE Transactions on Biomedical Circuits and Systems. 2013;7(3):236-242. doi: https://doi.org/10.1109/TBCAS.2012.2201258. 54. Meswania JM, Taylor SJG, Blunn GW. Design and characterization of a novel permanent magnet synchronous motor used in a growing prosthesis for young patients with bone cancer. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2008;222(3):393-402. doi: https://doi.org/10.1243/09544119JEIM247. 55. OrthopedicDesign&Technology. First Knee Replacement Surgery with Persona IQ Smart Knee: Orthopedic Design & Technology; 2022 [accessed 2022 Jul-29]. Available from: https://www.odtmag.com/contents/view_breaking-news/2021-10-13/first-knee-replacement-surgery-with-persona-iq-smart-knee/. 56. ZimmerBiomet. Persona IQ [accessed 2022 Jul-29]. Available from: https://www.zimmerbiomet.com/en/products-and-solutions/specialties/knee/persona-iq.html. 57. Taylor SJG, Walker PS. Forces and moments telemetered from two distal femoral replacements during various activities. Journal of Biomechanics. 2001;34(7):839-848. doi: https://doi.org/10.1016/S0021-9290(01)00042-2. 58. D’Lima DD, Patil S, Steklov N, Slamin JE, Colwell CWJ. THE CHITRANJAN RANAWAT AWARD: In Vivo Knee Forces after Total Knee Arthroplasty. Clin Orthop Relat R. 2005;440:45-49. doi: https://doi.org/10.1097/01.blo.0000186559.62942.8c. PubMed PMID: 00003086-200511000-00010. 59. D’Lima DD, Patil S, Steklov N, Chien S, Colwell CW. In vivo knee moments and shear after total knee arthroplasty. Journal of Biomechanics. 2007;40:S11-S17. doi: https://doi.org/10.1016/j.jbiomech.2007.03.004. 60. Heinlein B, Kutzner I, Graichen F, Bender A, Rohlmann A, Halder AM, et al. ESB clinical biomechanics award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months. Clinical Biomechanics. 2009;24(4):315-326. doi: https://doi.org/10.1016/j.clinbiomech.2009.01.011. 61. Kirking B, Krevolin J, Townsend C, Colwell CW, D’Lima DD. A multiaxial force-sensing implantable tibial prosthesis. Journal of Biomechanics. 2006;39(9):1744-1751. doi: https://doi.org/10.1016/j.jbiomech.2005.05.023. 62. Heinlein B, Graichen F, Bender A, Rohlmann A, Bergmann G. Design, calibration and pre-clinical testing of an instrumented tibial tray. Journal of Biomechanics. 2007;40:S4-S10. doi: https://doi.org/10.1016/j.jbiomech.2007.02.014. 63. Holmberg J, Alexander L, Rajamani R, Bechtold JE. Battery-Less Wireless Instrumented Knee Implant. Journal of Medical Devices. 2013;7(1). doi: https://doi.org/10.1115/1.4023412. 64. Cushner F, Schiller P, Gross J, Mueller JK, Hunter W. A total knee arthroplasty prosthesis capable of remote patient monitoring. Orthopaedic Proceedings. 2021;103-B(SUPP_9):18-18. doi: https://doi.org/10.1302/1358-992x.2021.9.018. 65. Cushner FD, Sculco PK, Long WJ. The Talking Knee Is a Reality: What Your Knee Can Tell You After Total Knee Arthroplasty. Journal of Orthopaedic Experience & Innovation. 2022. 66. Graichen F, Arnold R, Rohlmann A, Bergmann G. Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants. IEEE Transactions on Biomedical Engineering. 2007;54(2):253-261. doi: 10.1109/TBME.2006.886857. 67. Morris B, D D'Lima D, Slamin J, Kovacevic N, W. Arms S, P. Townsend C, et al. e-Knee: Evolution of the Electronic Knee Prosthesis: Telemetry Technology Development. JBJS. 2001;83-A Suppl 2:62-66. doi: 10.2106/00004623-200100021-00013. 68. Forchelet D, Simoncini M, Arami A, Bertsch A, Meurville E, Aminian K, et al. Enclosed electronic system for force measurements in knee implants. Sensors (Basel). 2014;14(8):15009-15021. doi: 10.3390/s140815009. PubMed PMID: 25196007. 69. Safaei M, Anton SR. Self-Powered Multifunctional Instrumented Knee Implant. ASME. 2018(51951):V002T006A008. doi: 10.1115/SMASIS2018-8078. PubMed Central PMCID: PMCSmart Materials, Adaptive Structures and Intelligent Systems. 70. D'Lima DD, Patil S, Steklov N, Colwell CW, Jr. The 2011 ABJS Nicolas Andry Award: 'Lab'-in-a-knee: in vivo knee forces, kinematics, and contact analysis. Clin Orthop Relat R. 2011;469(10):2953-2970. doi: https://doi.org/10.1007/s11999-011-1916-9. Epub 2011/05/20. PubMed PMID: 21598121. 71. Almouahed S, Hamitouche C, Stindel E, Roux C, editors. New trends in instrumented knee prostheses. 2008 3rd International Conference on Information and Communication Technologies: From Theory to Applications; 2008 7-11 April 2008. 72. Camp J, F. Graboyes R. Us Medical Devices: Choices and Consequences. SSRN Electronic Journal. 2018. doi: 10.2139/ssrn.3191321. 73. Arami A, Simoncini M, Atasoy O, Hasenkamp W, Ali S, Bertsch A, et al., editors. Instrumented prosthesis for knee implants monitoring. 2011 IEEE International Conference on Automation Science and Engineering; 2011 24-27 Aug. 2011. 74. Baronio G, Luciano V, Sardini E, Serpelloni M. Design considerations of an electromechanical generator implanted in human total knee prosthesis. International Journal of Mechatronics and Manufacturing Systems. 2013;6(3):270-284. doi: 10.1504/ijmms.2013.056453. PubMed PMID: 56453. 75. Ibrahim A, Jain M, Salman E, Willing R, Towfighian S. A Smart Knee Implant Using Triboelectric Energy Harvesters. Smart Materials and Structures. 2018. doi: https://doi.org/10.1088/1361-665X/aaf3f1. 76. Mentink MJA. Measurement of bearing load in unicompartmental knee arthroplasty using an instrumented knee bearing. PhD Thesis 2014. 77. Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on medical devices, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directives 90/385/EEC and 93/42/EEC (Text with EEA relevance.). 78. Kurtz SM. 2 - From Ethylene Gas to UHMWPE Component: The Process of Producing Orthopedic Implants. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 7-20. 79. Scott CEH, Eaton MJ, Nutton RW, Wade FA, Evans SL, Pankaj P. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty. Bone & Joint Research. 2017;6(1):22-30. doi: 10.1302/2046-3758.61.Bjr-2016-0142.R1. 80. Rajamäki A, Niemeläinen M, Junnila M, Lehtovirta L, Karsikas M, Ponkilainen V, et al. Thicker polyethylene inserts (≥ 13 mm) increase the risk for early failure after primary cruciate-retaining total knee arthroplasty (TKA): a single-centre study of 7643 TKAs. Knee Surgery, Sports Traumatology, Arthroscopy. 2023;31(3):1018-1025. doi: 10.1007/s00167-022-07189-8. 81. Muratoglu OK, Bragdon CR. 15 - Highly Cross-Linked and Melted UHMWPE. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 264-273. 82. Spece H, Schachtner JT, MacDonald DW, Klein GR, Mont MA, Lee G-C, et al. Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty. The Journal of Arthroplasty. 2019;34(12):3088-3093. doi: https://doi.org/10.1016/j.arth.2019.07.018. 83. Kang JY, Lee YS. Same-Level Fracture of the Tibial Metal Tray and Polyethylene Insert After Total Knee Arthroplasty. Orthopedics. 2016;39(4):e787-789. doi: 10.3928/01477447-20160513-03. PubMed PMID: 27203415. 84. Li AE, Sneag DB, Miller TT, Lipman JD, Padgett DE, Potter HG. MRI of Polyethylene Tibial Inserts in Total Knee Arthroplasty: Normal and Abnormal Appearances. American Journal of Roentgenology. 2016;206(6):1264-1271. doi: 10.2214/AJR.15.15107. 85. Teeter MG, McAuley JP, Naudie DD. Fracture of Two Moderately Cross-Linked Polyethylene Tibial Inserts in a TKR Patient. Case Rep Orthop. 2014;2014:491384-491384. doi: 10.1155/2014/491384. Epub 2014/01/08. PubMed PMID: 24511401. 86. Currier BH, Currier JH, Franklin KJ, Mayor MB, Reinitz SD, Van Citters DW. Comparison of Wear and Oxidation in Retrieved Conventional and Highly Cross-Linked UHMWPE Tibial Inserts. The Journal of Arthroplasty. 2015;30(12):2349-2353. doi: https://doi.org/10.1016/j.arth.2015.06.014. 87. Bei Y, Fregly B. The relationship between contact pressure, insert thickness, and mild wear in total knee replacements. CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES. 2004;6:145-152. 88. Collier JP, Mayor MB, McNamara JL, Surprenant VA, Jensen RE. Analysis of the Failure of 122 Polyethylene Inserts From Uncemented Tibial Knee Components. Clinical Orthopaedics and Related Research®. 1991;273:232-242. PubMed PMID: 00003086-199112000-00034. 89. Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. JBJS. 1986;68(7):1041-1051. PubMed PMID: 00004623-198668070-00010. 90. Pijls BG, Van der Linden-Van der Zwaag HMJ, Nelissen RGHH. Polyethylene thickness is a risk factor for wear necessitating insert exchange. Int Orthop. 2012;36(6):1175-1180. doi: 10.1007/s00264-011-1412-6. 91. Institution TBS. BS EN ISO 21536:2009+A1:2014. Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants. 2009. 92. FDA. Knee Joint Patellofemorotibial and Femorotibial Metal/Polymer Porous-Coated Uncemented Prostheses - Class II Special Controls Guidance Document for Industry and FDA 2003/2018 [accessed 2020 May 14]. Available from: https://www.fda.gov/medical-devices/guidance-documents-medical-devices-and-radiation-emitting-products/knee-joint-patellofemorotibial-and-femorotibial-metalpolymer-porous-coated-uncemented-prostheses. 93. Koh Y-G, Jung K-H, Hong H-T, Kim K-M, Kang K-T. Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance. Journal of Clinical Medicine. 2019;8:2023. doi: 10.3390/jcm8112023. 94. MatOrtho. SAIPH Knee System [accessed 2020 January 28]. Available from: https://www.matortho.com/products/saiph-knee-system/. 95. Corin_group. Global APEX Knee™ Reconstruction System [accessed 2020 January 28]. Available from: https://www.coringroup.com/assets/product-resources/apex/GKL-014-Global-Apex-Knee-System-Brochure-REV-0.pdf. 96. Kobayashi H, Mitsugi N, Mochida Y, Taki N, Akamatsu Y, Aratake M, et al. Mid- term results of stryker® scorpio plus mobile bearing total knee arthroplasty. Sports Medicine, Arthroscopy, Rehabilitation, Therapy & Technology. 2012;4(1):38. doi: 10.1186/1758-2555-4-38. 97. Zimmer. Zimmer®NexGen® Trabecular Metal™ Monoblock Tibial Components Surgical Technique Addendum 2012 [accessed 2020 May 15]. Available from: https://www.zimmerbiomet.com/content/dam/zimmer-biomet/medical-professionals/000-surgical-techniques/knee/zimmer-nexgen-trabecular-metal-monoblock-tibial-components-surgical-technique.pdf. 98. Klein GR, Levine HB, Hartzband MA. Removal of a Well-Fixed Trabecular Metal Monoblock Tibial Component. The Journal of Arthroplasty. 2008;23(4):619-622. doi: https://doi.org/10.1016/j.arth.2007.05.004. 99. Biomet. The Oxford® Partial Knee [accessed 2020 January 28]. Available from: http://www.biomet.com/web_accents/biomet_products/oxfordSignature.cfm. 100. MedicalEXPO. Biomet, Vanguard XP [accessed 2020 January 28]. Available from: https://www.medicalexpo.com/prod/biomet/product-74862-695258.html. 101. Conformis. iTotal [accessed 2020 January 28]. Available from: https://www.conformis.com/custom-made-knee-implants/products/itotal/. 102. Harman MK, DesJardins J, Benson L, Banks SA, LaBerge M, Hodge WA. Comparison of polyethylene tibial insert damage from in vivo function and in vitro wear simulation. J Orthop Res. 2009;27(4):540-548. doi: 10.1002/jor.20743. Epub 2008/10/22. PubMed PMID: 18932244. 103. Haider H. 32 - Tribological Assessment of UHMWPE in the Knee. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 599-634. 104. Mendenhall S. 2008 Hip and Knee Implant Review. Orthopedic Network News. 2008 August 10. 105. Bowden AE, Bergström J. 39 - Computer Modeling and Simulation of UHMWPE. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 753-771. 106. Teeter MG, Parikh A, Taylor M, Sprague J, Naudie DD. Wear and Creep Behavior of Total Knee Implants Undergoing Wear Testing. The Journal of Arthroplasty. 2015;30(1):130-134. doi: https://doi.org/10.1016/j.arth.2014.08.001. 107. AMTI. ADL Knee Simulator 6-Station Joint Simulator [accessed 2023 May 07]. Available from: https://www.amti.biz/product/knee-simulator/. 108. ISO. ISO 14243-1:2009+A1:2020. Implants for surgery. Wear of total knee-joint prostheses. Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test. 109. ISO. ISO 14243-3:2014+A1:2020. Implants for surgery. Wear of total knee-joint prostheses. Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test. 110. Abdelgaied A, Fisher J, Jennings LM. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements. Journal of the Mechanical Behavior of Biomedical Materials. 2018;78:282-291. doi: https://doi.org/10.1016/j.jmbbm.2017.11.022. 111. ASTM F2003-02(2015), Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air. West Conshohocken, PA: ASTM International; 2015. 112. ASTM F2777-16, Standard Test Method for Evaluating Knee Bearing (Tibial Insert) Endurance and Deformation Under High Flexion. West Conshohocken, PA: ASTM International; 2016. 113. EndoLab. [accessed 2020 February 19]. Available from: https://www.endolab.org/default.asp. 114. ASTM F1800-19e1, Standard Practice for Cyclic Fatigue Testing of Metal Tibial Tray Components of Total Knee Joint Replacements. West Conshohocken, PA: ASTM International; 2019. 115. ASTM F2083-12, Standard Specification for Knee Replacement Prosthesis. West Conshohocken, PA: ASTM International; 2012. 116. Villa T, Migliavacca F, Gastaldi D, Colombo M, Pietrabissa R. Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations. Journal of Biomechanics. 2004;37(1):45-53. doi: https://doi.org/10.1016/S0021-9290(03)00255-0. 117. Ahir SP, Blunn GW, Haider H, Walker PS. Evaluation of a testing method for the fatigue performance of total knee tibial trays. Journal of Biomechanics. 1999;32(10):1049-1057. doi: https://doi.org/10.1016/S0021-9290(99)00094-9. 118. Fish J, Belytschko T. Introduction. A First Course in Finite Elements. Chichester: Wiley; 2007. p. 1-9. 119. Anderson AE, Ellis BJ, Weiss JA. Verification, validation and sensitivity studies in computational biomechanics. Computer methods in biomechanics and biomedical engineering. 2007;10(3):171-184. doi: 10.1080/10255840601160484. PubMed PMID: 17558646. 120. Bergmann G, Graichen F, Rohlmann A, Westerhoff P, Heinlein B, Bender A, et al. Design and Calibration of Load Sensing Orthopaedic Implants. Journal of Biomechanical Engineering. 2008;130(2). doi: 10.1115/1.2898831. 121. Pegg EC, Murray DW, Pandit HG, O’Connor JJ, Gill HS. Fracture of mobile unicompartmental knee bearings: A parametric finite element study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2013;227(11):1213-1223. doi: 10.1177/0954411913494326. PubMed PMID: 23940210. 122. Hasenkamp W, Thevenaz N, Villard J, Bertsch A, Arami A, Aminian K, et al. Design and test of a MEMS strain-sensing device for monitoring artificial knee implants. Biomedical Microdevices. 2013;15(5):831-839. doi: 10.1007/s10544-013-9770-z. 123. ASTM F3161-16, Standard Test Method for Finite Element Analysis (FEA) of Metallic Orthopaedic Total Knee Femoral Components under Closing Conditions. West Conshohocken, PA: ASTM International; 2016. 124. ASTM F3334-19, Standard Practice for Finite Element Analysis (FEA) of Metallic Orthopaedic Total Knee Tibial Components. West Conshohocken, PA: ASTM International; 2019. 125. Kurtz SM. 1 - A Primer on UHMWPE. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 1-6. 126. ACNIS_INTERNATIONAL. POLYMERS [accessed 2020 06-Jan]. Available from: http://www.acnis-titanium.com/en/polymers/. 127. Medacta. GMK Primary product range [accessed 2020 06-Jan]. Available from: https://www.medacta.com/EN/gmk-primary. 128. Malito LG, Arevalo S, Kozak A, Spiegelberg S, Bellare A, Pruitt L. Material properties of ultra-high molecular weight polyethylene: Comparison of tension, compression, nanomechanics and microstructure across clinical formulations. Journal of the Mechanical Behavior of Biomedical Materials. 2018;83:9-19. doi: https://doi.org/10.1016/j.jmbbm.2018.03.029. 129. Bianchi F, rinaldi S, Quagliana I, Siccardi F. Polyethylene in TKA: do we really need cross-linked polyethylene? MORE Journal. 2011;01. 130. Ansari F, Gludovatz B, Kozak A, Ritchie RO, Pruitt LA. Notch fatigue of ultrahigh molecular weight polyethylene (UHMWPE) used in total joint replacements. Journal of the Mechanical Behavior of Biomedical Materials. 2016;60:267-279. doi: https://doi.org/10.1016/j.jmbbm.2016.02.014. 131. Zheng X, Wu K, Wang J, Ma L, Yu J, Xu J. Mechanical characteristics of medical grade UHMWPE under dynamic compression. Journal of Materials Science: Materials in Medicine. 2019;30(5):50. doi: 10.1007/s10856-019-6254-6. 132. Lu Y-C, Wu C-Y, Chang T-K, Huang C-H, Huang C-H. Elastoplastic behavior of highly cross-linked and vitamin E-stabilized polyethylene – A biomechanical study. Clinical Biomechanics. 2018;59:152-158. doi: https://doi.org/10.1016/j.clinbiomech.2018.09.021. 133. Johnston HE. The Eﬀect of Surgical Alignment and Soft Tissue Constraints on the Kinematics, Contact Pressure and Wear of a Total Knee Replacement. PhD thesis. [PhD thesis]. Leeds: University of Leeds; 2019. 134. Aherwar A, Singh A, Patnaik A. Current and future biocompatibility aspects of biomaterials for hip prosthesis. AIMS Journal. 2016;3:23-43. doi: 10.3934/bioeng.2016.1.23. 135. ABAQUS ducumentation. Contact constraint enforcement methods in Abaqus/Standard. [accessed 2022 Jul 14]. Available from: https://abaqus-docs.mit.edu/2017/English/SIMACAEITNRefMap/simaitn-c-contactconstraints.htm#:~:text=The%20default%20constraint%20enforcement%20method,overclosure%20relationship%20is%20in%20effect. 136. Budynas R, Nisbett K. Shigley's Mechanical Engineering Design. 9th edition: McGraw-Hill Higher Education; 2010. 137. Smith&Nephew. JOURNEY II XR Measurements [accessed 2020 Jun 05]. Available from: https://www.smith-nephew.com/global/assets/pdf/products/surgical/journeyii-xr-specs.pdf. 138. Stryker. RESTORIS® MCK MultiCompartmental Knee System [accessed 2020 Jun 05]. Available from: https://www.strykermeded.com/media/1708/restoris-mck-technical-data-sheet.pdf. 139. Medacta. MOTO® Medial Partial Knee System [accessed 2020 Jun 05]. Available from: https://media.medacta.com/media/moto-specification-guide-9938moto11sg-rev02.pdf. 140. Nabrdalik M, Sobociński M. Numerical analysis of stress distribution generated in spherical polyethylene inserts by knee joint endoprotheses’ sleds %J Polish Journal of Chemical Technology. 2019;21(2):1-5. doi: doi:10.2478/pjct-2019-0012. 141. ABAQUS Analysis User's Manual. ABAQUS Online Documentation: Version 6.6. Section 18.2.1 Classical metal plasticity.2006. 142. Godest AC, Beaugonin M, Haug E, Taylor M, Gregson PJ. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. Journal of Biomechanics. 2002;35(2):267-275. doi: https://doi.org/10.1016/S0021-9290(01)00179-8. 143. Abaqus. Abaqus Analysis User`s Manual 6.10. Chapter 25.1.4 Three-dimensional solid element library [accessed 2023 Jan 03]. Available from: http://130.149.89.49:2080/v6.10/books/usb/default.htm?startat=pt06ch25s01ael03.html. 144. Abaqus. Abaqus Analysis User`s Manual 6.11. Chapter 27.1.1 Solid (continuum) elements [accessed 2023 Jan 03]. Available from: http://130.149.89.49:2080/v6.11/books/usb/default.htm?startat=pt06ch27s01alm01.html. 145. Abaqus. Abaqus Analysis User`s Manual 6.6. Chapter 21.1.4 Section controls [accessed 2023 Jan 03]. Available from: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/usb/default.htm?startat=pt06ch21s01aus90.html. 146. ABAQUS Analysis User's Manual. ABAQUS Online Documentation: Version 6.6-1. Section 29.2.11.2006. 147. Jahani F. Modelling of dynamic edge loading in total hip replacements with ceramic on plyethylene bearings. PhD Thesis. [PhD Thesis]: University of Leeds; 2017. 148. Liu F, Wang M, Wang J, Du W. The influence of frontally flat bearing design on contact mechanics and kinematics in total knee joint replacements. Tribology International. 2019;136:23-30. doi: https://doi.org/10.1016/j.triboint.2019.03.006. 149. Lee K-Y, Pienkowski D. Viscoelastic recovery of creep-deformed ultra-high molecular weight polyethylene (UHMWPE). ASTM special technical publication. 1998;1307:30-36. 150. Drewniak EI, Crisco JJ, Spenciner DB, Fleming BC. Accuracy of circular contact area measurements with thin-film pressure sensors. Journal of Biomechanics. 2007;40(11):2569-2572. doi: https://doi.org/10.1016/j.jbiomech.2006.12.002. 151. Khosravipour I, Pejhan S, Luo Y, Wyss UP. Customized surface-guided knee implant: Contact analysis and experimental test. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2017;232(1):90-100. doi: 10.1177/0954411917744586. 152. Chen P, Colwell C, D’lima D. A Nonlinear Viscoelastic Finite Element Model of Polyethylene. Molecular & Cellular Biomechanics. 2011;8(2):135. 153. Bitter T, Khan I, Marriott T, Lovelady E, Verdonschot N, Janssen D. The effects of manufacturing tolerances and assembly force on the volumetric wear at the taper junction in modular total hip arthroplasty. Computer Methods in Biomechanics and Biomedical Engineering. 2019;22(13):1061-1072. doi: 10.1080/10255842.2019.1627524. 154. Institution BS. BS EN 22768-1:1993, ISO 2768-1:1989. General tolerances. Tolerances for linear and angular dimensions without individual tolerance indications. 1989. 155. OrthoLoad. Standard Loads Knee Joint 2014 [accessed 2020 Nov 05]. Available from: https://orthoload.com/test-loads/standard-loads-knee-joint/. 156. Abaqus. Abaqus Analysis User`s Manual 6.6. Chapter 2.4 Comparison of implicit and explicit procedures [accessed 2023 Feb 17]. Available from: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/gsa/default.htm?startat=ch02s04.html. 157. Abaqus. Abaqus Analysis User`s Manual 6.6. Chapter 3.1 Types of problems suited for ABAQUS/Explicit [accessed 2023 Feb 17]. Available from: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/gsx/default.htm?startat=ch03s01.html. 158. Research Computing at the University of Leeds. ARC Acknowledgement [accessed 2022 Sep 28]. Available from: https://arcdocs.leeds.ac.uk/usage/acknowledgement.html. 159. Research Computing at the University of Leeds. ARC3. Available from: https://arcdocs.leeds.ac.uk/systems/arc3.html. 160. MILLER RH, EDWARDS WB, BRANDON SCE, MORTON AM, DELUZIO KJ. Why Don’t Most Runners Get Knee Osteoarthritis? A Case for Per-Unit-Distance Loads. Medicine & Science in Sports & Exercise. 2014;46(3):572-579. doi: 10.1249/mss.0000000000000135. PubMed PMID: 00005768-201403000-00018. 161. Abaqus. Abaqus Analysis User`s Manual 6.6. Chapter 7. Linear Dynamics 7.1 Introduction [accessed 2023 Feb 24]. Available from: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/gsa/default.htm?startat=ch07s01.html. 162. Abaqus. Abaqus Analysis User`s Manual 6.14. 6.3.2 Implicit dynamic analysis using direct integration [accessed 2023 Jan 03]. Available from: http://130.149.89.49:2080/v6.14/books/usb/default.htm?startat=pt03ch06s03at07.html. 163. Piziali RL, Seering WP, Nagel DA, Schurman DJ. The function of the primary ligaments of the knee in anterior-posterior and medial-lateral motions. Journal of Biomechanics. 1980;13(9):777-784. doi: https://doi.org/10.1016/0021-9290(80)90239-0. 164. Völlner F, Pilsl U, Craiovan B, Zeman F, Schneider M, Wörner M, et al. Stability of knee ligament complex of Thiel-embalmed cadaver compared to in vivo knee. Journal of the Mechanical Behavior of Biomedical Materials. 2017;71:392-396. doi: https://doi.org/10.1016/j.jmbbm.2017.04.009. 165. Markolf K, Mensch J, Amstutz H. Stiffness and laxity of the knee--the contributions of the supporting structures. A quantitative in vitro study. JBJS. 1976;58(5):583-594. PubMed PMID: 00004623-197658050-00001. 166. Haider H, Walker P, DesJardins J, Blunn G. Effects of Patient and Surgical Alignment Variables on Kinematics in TKR Simulation Under Force-Control. Journal of Astm International. 2006;3. doi: 10.1520/JAI100248. 167. Wang X-H, Bi Z, Dong X, Hu S-Y, Xu L-j, Cheng C-K. Increasing the height of the anterior lip on a tibial insert in a posterior stabilized knee prosthesis has little effect on the wear rate. Med Eng Phys. 2021;91:48-53. doi: https://doi.org/10.1016/j.medengphy.2021.03.007. 168. Maag C, Cracaoanu I, Langhorn J, Heldreth M. Total knee replacement wear during simulated gait with mechanical and anatomic alignments. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2021;235(5):515-522. doi: 10.1177/0954411921991269. PubMed PMID: 33522419. 169. D'Lima DD, Steklov N, Fregly BJ, Banks SA, Colwell Jr. CW. In vivo contact stresses during activities of daily living after knee arthroplasty. Journal of Orthopaedic Research. 2008;26(12):1549-1555. doi: https://doi.org/10.1002/jor.20670. 170. Bartel DL, Rawlinson JJ, Burstein AH, Ranawat CS, Flynn WFJ. Stresses in Polyethylene Components of Contemporary Total Knee Replacements. Clinical Orthopaedics and Related Research®. 1995;317:76-82. PubMed PMID: 00003086-199508000-00012. 171. Kurtz SM, Bartel DL, Rimnac CM. Postirradiation Aging Affects Stress and Strain in Polyethylene Components. Clinical Orthopaedics and Related Research®. 1998;350:209-220. PubMed PMID: 00003086-199805000-00029. 172. Mell SP, Fullam S, Wimmer MA, Lundberg HJ. Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2018;232(6):545-552. doi: 10.1177/0954411918770700. PubMed PMID: 29658386. 173. Chen Z, Zhang J, Gao Y, Chen S, Zhang X, Jin Z. Effects of interference assembly of a tibial insert on the tibiofemoral contact mechanics in total knee replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2019;233(9):948-953. doi: 10.1177/0954411919859905. PubMed PMID: 31234760. 174. Schwiesau J, Schilling C, Utzschneider S, Jansson V, Fritz B, Blömer W, et al. Knee wear simulation under conditions of highly demanding daily activities – Influence on an unicompartmental fixed bearing knee design. Med Eng Phys. 2013;35(8):1204-1211. doi: https://doi.org/10.1016/j.medengphy.2012.12.015. 175. Pruitt LA, Ansari F, Kury M, Mehdizah A, Patten EW, Huddlestein J, et al. Clinical trade-offs in cross-linked ultrahigh-molecular-weight polyethylene used in total joint arthroplasty. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2013;101B(3):476-484. doi: https://doi.org/10.1002/jbm.b.32887. 176. Completo A, Fonseca F, Simões JA. Finite Element and Experimental Cortex Strains of the Intact and Implanted Tibia. Journal of Biomechanical Engineering. 2007;129(5):791-797. doi: 10.1115/1.2768382. 177. Oosterom R, van Ostayen RAJ, Antonelli V, Bersee HEN. Effect of Interface Conditions between Ultrahigh Molecular Weight Polyethylene and Polymethyl Methacrylate Bone Cement on the Mechanical Behaviour of Total Shoulder Arthroplasty. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2005;219(6):425-435. doi: 10.1243/095441105x34455. PubMed PMID: 16312102. 178. Shi W, Li XY, Dong H. Improved wear resistance of ultra-high molecular weight polyethylene by plasma immersion ion implantation. Wear. 2001;250(1):544-552. doi: https://doi.org/10.1016/S0043-1648(01)00636-6. 179. Halloran JP, Petrella AJ, Rullkoetter PJ. Explicit finite element modeling of total knee replacement mechanics. Journal of Biomechanics. 2005;38(2):323-331. doi: https://doi.org/10.1016/j.jbiomech.2004.02.046. 180. Willing R, Kim IY. A holistic numerical model to predict strain hardening and damage of UHMWPE under multiple total knee replacement kinematics and experimental validation. Journal of Biomechanics. 2009;42(15):2520-2527. doi: https://doi.org/10.1016/j.jbiomech.2009.07.008. 181. Bischoff JE, Dharia MA, Hertzler JS, Schipper ON. Evaluation of Total Ankle Arthroplasty Using Highly Crosslinked Ultrahigh-Molecular-Weight Polyethylene Subjected to Physiological Loading. Foot & Ankle International. 2019;40(8):880-887. doi: 10.1177/1071100719847645. PubMed PMID: 31091414. 182. Brockett CL, Abdelgaied A, Haythornthwaite T, Hardaker C, Fisher J, Jennings LM. The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2016;230(5):429-439. doi: 10.1177/0954411916645134. PubMed PMID: 27160561. 183. Pandey RM. Approaches to sample size calculation in comparative studies. The Indian Journal of Pediatrics. 1999;66(4):533-538. doi: 10.1007/BF02727163. 184. Jones SR, Carley S, Harrison M. An introduction to power and sample size estimation. Emerg Med J. 2003;20(5):453-458. doi: 10.1136/emj.20.5.453. Epub 2003/09/05. PubMed PMID: 12954688; PubMed Central PMCID: PMCPMC1726174. 185. Rapuri VR, Clarke HD, Spangehl MJ, Beauchamp CP. Five Cases of Failure of the Tibial Polyethylene Insert Locking Mechanism in One Design of Constrained Knee Arthroplasty. The Journal of Arthroplasty. 2011;26(6):976.e921-976.e924. doi: https://doi.org/10.1016/j.arth.2010.07.013. 186. Sanders AP, Raeymaekers B. The effect of polyethylene creep on tibial insert locking screw loosening and back-out in prosthetic knee joints. Journal of the Mechanical Behavior of Biomedical Materials. 2014;38:1-5. doi: https://doi.org/10.1016/j.jmbbm.2014.06.002. 187. von Keudell A, Agrawal K, Rubash HE. Atraumatic Late Screw Loosening of the Tibial Polyethylene Insert Locking Mechanism in a Constrained Knee Arthroplasty: A Case Report. The Orthopaedic Journal at Harvard Medical School. 2016;17:93-98. 188. Vasiljeva K. Ksenija Vasiljeva ORCID 0000-0002-2049-6491 [accessed 2023 Feb 27]. Available from: https://orcid.org/0000-0002-2049-6491. 189. Carpenter T. Thomas Carpenter ORCID 0000-0001-5676-1739 [accessed 2023 Feb 27]. Available from: https://orcid.org/0000-0001-5676-1739. 190. PARALLAX. PLX-DAQ 2020 [updated 2021 Dec 01; accessed 2023 Jan 16]. Available from: https://www.parallax.com/package/plx-daq/. 191. NetDevil. PLX-DAQ version 2 - now with 64 bit support! (and further new features) [Arduino forum]. 2016 [accessed 2023 Jan 16]. Open source software]. Available from: https://forum.arduino.cc/t/plx-daq-version-2-now-with-64-bit-support-and-further-new-features/420628. 192. Rossom Sv, Smith CR, Thelen DG, Vanwanseele B, Assche DV, Jonkers I. Knee Joint Loading in Healthy Adults During Functional Exercises: Implications for Rehabilitation Guidelines. Journal of Orthopaedic & Sports Physical Therapy. 2018;48(3):162-173. doi: 10.2519/jospt.2018.7459. PubMed PMID: 29308697. 193. Arami A, Simoncini M, Atasoy O, Ali S, Hasenkamp W, Bertsch A, et al. Instrumented Knee Prosthesis for Force and Kinematics Measurements. IEEE Transactions on Automation Science and Engineering. 2013;10(3):615-624. doi: 10.1109/TASE.2012.2226030. 194. ISO. ISO 14879-1:2020. Implants for surgery. Total kneejoint prostheses. Determination of endurance properties of knee tibial trays. 195. Ahir SP. Development of clinically relevant testing methods for the fatigue performance for tibial trays. Doctoral thesis.: University College London (University of London); 2004. 196. Kandahari AM, Yang X, Laroche KA, Dighe AS, Pan D, Cui Q. A review of UHMWPE wear-induced osteolysis: the role for early detection of the immune response. Bone Res. 2016;4:16014. doi: 10.1038/boneres.2016.14. Epub 2016/07/29. PubMed PMID: 27468360; PubMed Central PMCID: PMCPMC4941197. 197. Okazaki Y. Effects of fine microstructures and precipitates of laser-sintered Co–28Cr–6Mo alloy femoral components on wear rate of UHMWPE inserts in a knee joint simulator. Journal of the Mechanical Behavior of Biomedical Materials. 2020;112:103998. doi: https://doi.org/10.1016/j.jmbbm.2020.103998. 198. MettlerToledo. Operating Instructions Excellence Plus Analytical Balances XP Models - Part 1 [accessed 2023 Jan 12]. Available from: https://www.mt.com/dam/P5/labtec/02_Analytical_Balances/03_XP/03_Documentations/03_Operating_Instructions/OI_XP_Analytical_Part_1_EN.pdf. 199. Dodge Y. The concise encyclopedia of statistics. Page 427 Pooled Variance: Springer Science & Business Media; 2008. 200. Okazaki Y, Hosoba M, Miura S, Mochizuki T. Effects of knee simulator control method and radiation dose on UHMWPE wear rate, and relationship between wear rate and clinical revision rate in National Joint Registry. Journal of the Mechanical Behavior of Biomedical Materials. 2019;90:182-190. doi: https://doi.org/10.1016/j.jmbbm.2018.09.034. 201. Fisher J, McEwen H, Tipper J, Jennings L, Farrar R, Stone M, et al. Wear-simulation analysis of rotating-platform mobile-bearing knees. Orthopedics. 2006;29(9):S36. 202. Affatato S, Valigi MC, Logozzo S. Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners. Materials. 2017;10(4):364. PubMed PMID: doi:10.3390/ma10040364."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Integrated Ph.D and Master"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/L014823/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/33871/1/Edgars%20Kelmers%2C%20PhD%20thesis%20Nov-2023%2C%20Mechanical%20Design%20Optimisation%20of%20a%20Tibial%20Insert%20for%20use%20in%20Instrumented%20Total%20Knee%20Replacement.pdf","https://etheses.whiterose.ac.uk/id/eprint/33871/2/Video%201%2C%20CPRESS%2C%20original%20unmodified%20tibial%20insert%2C%20GMK%20Primary%20size%203%20left.avi","https://etheses.whiterose.ac.uk/id/eprint/33871/3/Video%202%2C%20CPRESS%2C%20modified%20tibial%20insert%20with%20a%20hole%2C%20GMK%20Primary%20size%203%20left.avi"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This PhD research has presented guidelines on how to design, manufacture, and test a smart knee implant. The aim of this PhD research was to investigate how to modify a conventional tibial insert design to incorporate sensors and electronic components whilst ensuring patient safety. Several manufacturing methods were developed to address manufacturing and assembling challenges. Computational and experimental studies were carried out to analyse the structural strength, wear performance, and safety of a modified tibial insert. Additional experimental studies were performed to illustrate the feasibility and practical applications for making measurements with embedded sensors. Previous studies on instrumented tibial inserts did not address manufacturing limitations nor safety concerns."]},{"key":"dc:format","label":"Dc Format","values":["text","video"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Mechanical Design Optimisation of a Tibial Insert for use in Instrumented Total Knee Replacement"]}]}],"canonical_facts":{"dc:contributor.advisor":["Pandit, Hemant","van Duren, Bernard H.","Jennings, Louise M.","Wilcox, Ruth K."],"dc:contributor.sponsor":["Engineering and Physical Sciences Research Council (EPSRC)"],"dc:creator":["Kelmers, Edgars"],"dc:date":["2023-11"],"dc:date.issued":["2023-11"],"dc:description.abstract":["This PhD research has presented guidelines on how to design, manufacture, and test a smart knee implant. The aim of this PhD research was to investigate how to modify a conventional tibial insert design to incorporate sensors and electronic components whilst ensuring patient safety. Several manufacturing methods were developed to address manufacturing and assembling challenges. Computational and experimental studies were carried out to analyse the structural strength, wear performance, and safety of a modified tibial insert. Additional experimental studies were performed to illustrate the feasibility and practical applications for making measurements with embedded sensors. Previous studies on instrumented tibial inserts did not address manufacturing limitations nor safety concerns."],"dc:format":["text","video"],"dc:identifier.grantnumber":["EP/L014823/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/33871/1/Edgars%20Kelmers%2C%20PhD%20thesis%20Nov-2023%2C%20Mechanical%20Design%20Optimisation%20of%20a%20Tibial%20Insert%20for%20use%20in%20Instrumented%20Total%20Knee%20Replacement.pdf","https://etheses.whiterose.ac.uk/id/eprint/33871/2/Video%201%2C%20CPRESS%2C%20original%20unmodified%20tibial%20insert%2C%20GMK%20Primary%20size%203%20left.avi","https://etheses.whiterose.ac.uk/id/eprint/33871/3/Video%202%2C%20CPRESS%2C%20modified%20tibial%20insert%20with%20a%20hole%2C%20GMK%20Primary%20size%203%20left.avi"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/33871/"],"dc:relation.references":["1. Human anatomy planes. National Cancer Institute. 2. Losina E, Thornhill TS, Rome BN, Wright J, Katz JN. The dramatic increase in total knee replacement utilization rates in the United States cannot be fully explained by growth in population size and the obesity epidemic. JBJS. 2012;94(3):201-207. doi: 10.2106/JBJS.J.01958. PubMed PMID: 22298051. 3. NJR. National Joint Registry for England, Wales, Northern Ireland and the Isle of Man: 15th Annual Report. 2018. 4. Inacio MCS, Paxton EW, Graves SE, Namba RS, Nemes S. Projected increase in total knee arthroplasty in the United States – an alternative projection model. Osteoarthr Cartil. 2017;25(11):1797-1803. doi: https://doi.org/10.1016/j.joca.2017.07.022. 5. Kurtz SM, Ong KL, Lau E, Widmer M, Maravic M, Gómez-Barrena E, et al. International survey of primary and revision total knee replacement. Int Orthop. 2011;35(12):1783-1789. doi: https://doi.org/10.1007/s00264-011-1235-5. Epub 2011/03/15. PubMed PMID: 21404023. 6. Schwartz AM, Farley KX, Guild GN, Bradbury TL. Projections and Epidemiology of Revision Hip and Knee Arthroplasty in the United States to 2030. The Journal of Arthroplasty. 2020;35(6, Supplement):S79-S85. doi: https://doi.org/10.1016/j.arth.2020.02.030. 7. Evans JT, Walker RW, Evans JP, Blom AW, Sayers A, Whitehouse MR. How long does a knee replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up. The Lancet. 2019;393(10172):655-663. doi: https://doi.org/10.1016/S0140-6736(18)32531-5. 8. Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). Hip, Knee & Shoulder Arthroplasty: 2019 Annual Report. Adelaide: AOA, 2019. 9. Torrão JND, dos Santos MPS, Ferreira JAF. Instrumented knee joint implants: innovations and promising concepts. Expert Review of Medical Devices. 2015;12(5):571-584. doi: https://doi.org/10.1586/17434440.2015.1068114. 10. Crescini D, Sardini E, Serpelloni M, . An Autonomous Sensor for Force Measurements in Human Knee Implants. Procedia Chem. 2009;1(1):718-721. doi: https://doi.org/10.1016/j.proche.2009.07.179. 11. Crescini D, Sardini E, Serpelloni M, . Design and test of an autonomous sensor for force measurements in human knee implants. Sens Actuator A Phys. 2011;166(1):1-8. doi: https://doi.org/10.1016/j.sna.2010.12.010. 12. Simoncini M. Design and integration of an instrumented knee prosthesis. PhD thesis 2014. 13. Clarke HD, Scott WN, Insall JN, Pedersen HB, Math KR, Vigorita VJ, et al. Anatomy. Insall & Scott Surgery of the Knee, 5th edition, chapter 1. Philadelphia: Elsevier Health Sciences; 2012. 14. Taylor WR, Schütz P, Bergmann G, List R, Postolka B, Hitz M, et al. A comprehensive assessment of the musculoskeletal system: The CAMS-Knee data set. Journal of Biomechanics. 2017;65:32-39. doi: https://doi.org/10.1016/j.jbiomech.2017.09.022. 15. Halder A, Kutzner I, Graichen F, Heinlein B, Beier A, Bergmann G. Influence of Limb Alignment on Mediolateral Loading in Total Knee Replacement: In Vivo Measurements in Five Patients. JBJS. 2012;94(11):1023-1029. doi: 10.2106/jbjs.K.00927. PubMed PMID: 00004623-201206060-00007. 16. Chen Z, Jin Z. Prediction of in-vivo kinematics and contact track of total knee arthroplasty during walking. Biosurface and Biotribology. 2016;2(3):86-94. doi: https://doi.org/10.1016/j.bsbt.2016.08.002. 17. Popoola OO, Yao JQ, Johnson TS, Blanchard CR. Wear, delamination, and fatigue resistance of melt-annealed highly crosslinked UHMWPE cruciate-retaining knee inserts under activities of daily living. Journal of Orthopaedic Research. 2010;28(9):1120-1126. doi: 10.1002/jor.21104. 18. Schwiesau J, Fritz B, Kutzner I, Bergmann G, Grupp TM. CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities. Biomed Res Int. 2014;2014:567374-567374. doi: 10.1155/2014/567374. Epub 2014/11/20. PubMed PMID: 25506594. 19. Grupp TM, Fritz B, Kutzner I, Schilling C, Bergmann G, Schwiesau J. Vitamin E stabilised polyethylene for total knee arthroplasty evaluated under highly demanding activities wear simulation. Acta Biomaterialia. 2017;48:415-422. doi: https://doi.org/10.1016/j.actbio.2016.10.031. 20. Saxby DJ, Modenese L, Bryant AL, Gerus P, Killen B, Fortin K, et al. Tibiofemoral contact forces during walking, running and sidestepping. Gait & Posture. 2016;49:78-85. doi: https://doi.org/10.1016/j.gaitpost.2016.06.014. 21. Bergmann G, Bender A, Graichen F, Dymke J, Rohlmann A, Trepczynski A, et al. Standardized loads acting in knee implants. PLoS One. 2014;9(1):e86035-e86035. doi: 10.1371/journal.pone.0086035. PubMed PMID: 24465856. 22. Messier SP, Pater M, Beavers DP, Legault C, Loeser RF, Hunter DJ, et al. Influences of alignment and obesity on knee joint loading in osteoarthritic gait. Osteoarthr Cartil. 2014;22(7):912-917. doi: 10.1016/j.joca.2014.05.013. Epub 2014/05/21. PubMed PMID: 24857973. 23. Kumar D, Manal KT, Rudolph KS. Knee joint loading during gait in healthy controls and individuals with knee osteoarthritis. Osteoarthr Cartil. 2013;21(2):298-305. doi: https://doi.org/10.1016/j.joca.2012.11.008. 24. Worsley P, Stokes M, Barrett D, Taylor M. Joint loading asymmetries in knee replacement patients observed both pre- and six months post-operation. Clinical Biomechanics. 2013;28(8):892-897. doi: https://doi.org/10.1016/j.clinbiomech.2013.07.014. 25. Kutzner I, Küther S, Heinlein B, Dymke J, Bender A, Halder AM, et al. The effect of valgus braces on medial compartment load of the knee joint – in vivo load measurements in three subjects. Journal of Biomechanics. 2011;44(7):1354-1360. doi: https://doi.org/10.1016/j.jbiomech.2011.01.014. 26. Lundberg HJ, Ngai V, Wimmer MA. Comparison of ISO Standard and TKR patient axial force profiles during the stance phase of gait. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2012;226(3):227-234. doi: 10.1177/0954411911431650. PubMed PMID: 22558837. 27. Winby CR, Lloyd DG, Besier TF, Kirk TB. Muscle and external load contribution to knee joint contact loads during normal gait. Journal of Biomechanics. 2009;42(14):2294-2300. doi: https://doi.org/10.1016/j.jbiomech.2009.06.019. 28. D'Lima DD, Steklov N, Patil S, Colwell CW, Jr. The Mark Coventry Award: in vivo knee forces during recreation and exercise after knee arthroplasty. Clin Orthop Relat R. 2008;466(11):2605-2611. doi: https://doi.org/10.1007/s11999-008-0345-x. Epub 2008/06/19. PubMed PMID: 18563502. 29. Messier SP, Gutekunst DJ, Davis C, DeVita P. Weight loss reduces knee-joint loads in overweight and obese older adults with knee osteoarthritis. Arthritis & Rheumatism. 2005;52(7):2026-2032. doi: 10.1002/art.21139. 30. Kurtz SM. 8 - The Origins and Adaptations of UHMWPE for Knee Replacements. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 106-122. 31. Kurtz SM, Zagorski M. 3 - Packaging and Sterilization of UHMWPE. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 21-32. 32. Kaivosoja E, Tiainen VM, Takakubo Y, Rajchel B, Sobiecki J, Konttinen YT, et al. 7 - Materials used for hip and knee implants. In: Affatato S, editor. Wear of Orthopaedic Implants and Artificial Joints: Woodhead Publishing; 2013. p. 178-218. 33. Medacta. GMK Primary [accessed 2020 May 15]. Available from: https://www.medacta.com/EN/gmk-primary. 34. Kurtz SM. 9 - The Clinical Performance of UHMWPE in Knee Replacements. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 123-144. 35. ISO. ISO 16087:2013 Implants for surgery — Roentgen stereophotogrammetric analysis for the assessment of migration of orthopaedic implants. 36. van IJsseldijk EA, Valstar ER, Stoel BC, de Ridder R, Nelissen RGHH, Kaptein BL. Measuring polyethylene wear in total knee arthroplasty by RSA: Differences between weight-bearing and non-weight-bearing positioning. Journal of Orthopaedic Research. 2014;32(4):613-617. doi: https://doi.org/10.1002/jor.22579. 37. Losina E, Katz JN. Total knee arthroplasty on the rise in younger patients: are we sure that past performance will guarantee future success? Arthritis Rheum. 2012;64(2):339-341. doi: 10.1002/art.33371. PubMed PMID: 22252374. 38. Nam D, Nunley RM, Barrack RL. Patient dissatisfaction following total knee replacement. BJJ. 2014;96-B(11_Supple_A):96-100. doi: https://doi.org/10.1302/0301-620x.96b11.34152. 39. Gunaratne R, Pratt DN, Banda J, Fick DP, Khan RJK, Robertson BW. Patient Dissatisfaction Following Total Knee Arthroplasty: A Systematic Review of the Literature. The Journal of Arthroplasty. 2017;32(12):3854-3860. doi: https://doi.org/10.1016/j.arth.2017.07.021. 40. Uvehammer J, Kärrholm J, Brandsson S, Herberts P, Carlsson L, Karlsson J, et al. In vivo kinematics of total knee arthroplasty: Flat compared with concave tibial joint surface. Journal of Orthopaedic Research. 2000;18(6):856-864. doi: 10.1002/jor.1100180603. 41. Ardestani MM, Moazen M, Jin Z. Contribution of geometric design parameters to knee implant performance: Conflicting impact of conformity on kinematics and contact mechanics. The Knee. 2015;22(3):217-224. doi: https://doi.org/10.1016/j.knee.2015.02.011. 42. Koh Y-G, Nam J-H, Kang K-T. Effect of geometric variations on tibiofemoral surface and post-cam design of normal knee kinematics restoration. Journal of Experimental Orthopaedics. 2018;5(1):53. doi: 10.1186/s40634-018-0167-z. 43. Li Y, Wang S, Wang Y, Yang M. Does Kinematic Alignment Improve Short-Term Functional Outcomes after Total Knee Arthroplasty Compared with Mechanical Alignment? A Systematic Review and Meta-analysis. J Knee Surg. 2018;31(01):078-086. doi: 10.1055/s-0037-1602136. Epub 01.05.2017. 44. Chen C, Li R. Cementless versus cemented total knee arthroplasty in young patients: a meta-analysis of randomized controlled trials. J Orthop Surg Res. 2019;14(1):262-262. doi: 10.1186/s13018-019-1293-8. PubMed PMID: 31426816. 45. Longo UG, Ciuffreda M, Mannering N, D'Andrea V, Cimmino M, Denaro V. Patellar Resurfacing in Total Knee Arthroplasty: Systematic Review and Meta-Analysis. The Journal of Arthroplasty. 2018;33(2):620-632. doi: 10.1016/j.arth.2017.08.041. 46. Verra WC, Boom LGHvd, Jacobs WCH, Schoones JW, Wymenga AB, Nelissen RGHH. Similar outcome after retention or sacrifice of the posterior cruciate ligament in total knee arthroplasty. Acta Orthop. 2015;86(2):195-201. doi: 10.3109/17453674.2014.973329. Epub 2014/10/17. PubMed PMID: 25323799. 47. Young T, Dowsey MM, Pandy M, Choong PF. A Systematic Review of Clinical Functional Outcomes After Medial Stabilized Versus Non-Medial Stabilized Total Knee Joint Replacement. Front Surg. 2018;5:25-25. doi: 10.3389/fsurg.2018.00025. PubMed PMID: 29696144. 48. Kaufman KR, Kovacevic N, Irby SE, Colwell CW. Instrumented implant for measuring tibiofemoral forces. Journal of Biomechanics. 1996;29(5):667-671. doi: https://doi.org/10.1016/0021-9290(95)00124-7. 49. ASTM F3141-17a, Standard Guide for Total Knee Replacement Loading Profiles. West Conshohocken, PA: ASTM International; 2017. 50. O’Connor C, Kiourti A. Wireless Sensors for Smart Orthopedic Implants. Journal of Bio- and Tribo-Corrosion. 2017;3(2):20. doi: https://doi.org/10.1007/s40735-017-0078-z. 51. Karipott SS, Veetil PM, Nelson BD, Guldberg RE, Ong KG. An Embedded Wireless Temperature Sensor for Orthopedic Implants. IEEE Sensors Journal. 2018;18(3):1265-1272. doi: https://doi.org/10.1109/JSEN.2017.2780226. 52. Pritchett JW. Heat Generated by Knee Prostheses. Clinical Orthopaedics and Related Research®. 2006;442:195-198. doi: https://doi.org/10.1097/01.blo.0000183739.50869.bb. PubMed PMID: 00003086-200601000-00031. 53. Liu X, Berger JL, Ogirala A, Mickle MH. A Touch Probe Method of Operating an Implantable RFID Tag for Orthopedic Implant Identification. IEEE Transactions on Biomedical Circuits and Systems. 2013;7(3):236-242. doi: https://doi.org/10.1109/TBCAS.2012.2201258. 54. Meswania JM, Taylor SJG, Blunn GW. Design and characterization of a novel permanent magnet synchronous motor used in a growing prosthesis for young patients with bone cancer. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2008;222(3):393-402. doi: https://doi.org/10.1243/09544119JEIM247. 55. OrthopedicDesign&Technology. First Knee Replacement Surgery with Persona IQ Smart Knee: Orthopedic Design & Technology; 2022 [accessed 2022 Jul-29]. Available from: https://www.odtmag.com/contents/view_breaking-news/2021-10-13/first-knee-replacement-surgery-with-persona-iq-smart-knee/. 56. ZimmerBiomet. Persona IQ [accessed 2022 Jul-29]. Available from: https://www.zimmerbiomet.com/en/products-and-solutions/specialties/knee/persona-iq.html. 57. Taylor SJG, Walker PS. Forces and moments telemetered from two distal femoral replacements during various activities. Journal of Biomechanics. 2001;34(7):839-848. doi: https://doi.org/10.1016/S0021-9290(01)00042-2. 58. D’Lima DD, Patil S, Steklov N, Slamin JE, Colwell CWJ. THE CHITRANJAN RANAWAT AWARD: In Vivo Knee Forces after Total Knee Arthroplasty. Clin Orthop Relat R. 2005;440:45-49. doi: https://doi.org/10.1097/01.blo.0000186559.62942.8c. PubMed PMID: 00003086-200511000-00010. 59. D’Lima DD, Patil S, Steklov N, Chien S, Colwell CW. In vivo knee moments and shear after total knee arthroplasty. Journal of Biomechanics. 2007;40:S11-S17. doi: https://doi.org/10.1016/j.jbiomech.2007.03.004. 60. Heinlein B, Kutzner I, Graichen F, Bender A, Rohlmann A, Halder AM, et al. ESB clinical biomechanics award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months. Clinical Biomechanics. 2009;24(4):315-326. doi: https://doi.org/10.1016/j.clinbiomech.2009.01.011. 61. Kirking B, Krevolin J, Townsend C, Colwell CW, D’Lima DD. A multiaxial force-sensing implantable tibial prosthesis. Journal of Biomechanics. 2006;39(9):1744-1751. doi: https://doi.org/10.1016/j.jbiomech.2005.05.023. 62. Heinlein B, Graichen F, Bender A, Rohlmann A, Bergmann G. Design, calibration and pre-clinical testing of an instrumented tibial tray. Journal of Biomechanics. 2007;40:S4-S10. doi: https://doi.org/10.1016/j.jbiomech.2007.02.014. 63. Holmberg J, Alexander L, Rajamani R, Bechtold JE. Battery-Less Wireless Instrumented Knee Implant. Journal of Medical Devices. 2013;7(1). doi: https://doi.org/10.1115/1.4023412. 64. Cushner F, Schiller P, Gross J, Mueller JK, Hunter W. A total knee arthroplasty prosthesis capable of remote patient monitoring. Orthopaedic Proceedings. 2021;103-B(SUPP_9):18-18. doi: https://doi.org/10.1302/1358-992x.2021.9.018. 65. Cushner FD, Sculco PK, Long WJ. The Talking Knee Is a Reality: What Your Knee Can Tell You After Total Knee Arthroplasty. Journal of Orthopaedic Experience & Innovation. 2022. 66. Graichen F, Arnold R, Rohlmann A, Bergmann G. Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants. IEEE Transactions on Biomedical Engineering. 2007;54(2):253-261. doi: 10.1109/TBME.2006.886857. 67. Morris B, D D'Lima D, Slamin J, Kovacevic N, W. Arms S, P. Townsend C, et al. e-Knee: Evolution of the Electronic Knee Prosthesis: Telemetry Technology Development. JBJS. 2001;83-A Suppl 2:62-66. doi: 10.2106/00004623-200100021-00013. 68. Forchelet D, Simoncini M, Arami A, Bertsch A, Meurville E, Aminian K, et al. Enclosed electronic system for force measurements in knee implants. Sensors (Basel). 2014;14(8):15009-15021. doi: 10.3390/s140815009. PubMed PMID: 25196007. 69. Safaei M, Anton SR. Self-Powered Multifunctional Instrumented Knee Implant. ASME. 2018(51951):V002T006A008. doi: 10.1115/SMASIS2018-8078. PubMed Central PMCID: PMCSmart Materials, Adaptive Structures and Intelligent Systems. 70. D'Lima DD, Patil S, Steklov N, Colwell CW, Jr. The 2011 ABJS Nicolas Andry Award: 'Lab'-in-a-knee: in vivo knee forces, kinematics, and contact analysis. Clin Orthop Relat R. 2011;469(10):2953-2970. doi: https://doi.org/10.1007/s11999-011-1916-9. Epub 2011/05/20. PubMed PMID: 21598121. 71. Almouahed S, Hamitouche C, Stindel E, Roux C, editors. New trends in instrumented knee prostheses. 2008 3rd International Conference on Information and Communication Technologies: From Theory to Applications; 2008 7-11 April 2008. 72. Camp J, F. Graboyes R. Us Medical Devices: Choices and Consequences. SSRN Electronic Journal. 2018. doi: 10.2139/ssrn.3191321. 73. Arami A, Simoncini M, Atasoy O, Hasenkamp W, Ali S, Bertsch A, et al., editors. Instrumented prosthesis for knee implants monitoring. 2011 IEEE International Conference on Automation Science and Engineering; 2011 24-27 Aug. 2011. 74. Baronio G, Luciano V, Sardini E, Serpelloni M. Design considerations of an electromechanical generator implanted in human total knee prosthesis. International Journal of Mechatronics and Manufacturing Systems. 2013;6(3):270-284. doi: 10.1504/ijmms.2013.056453. PubMed PMID: 56453. 75. Ibrahim A, Jain M, Salman E, Willing R, Towfighian S. A Smart Knee Implant Using Triboelectric Energy Harvesters. Smart Materials and Structures. 2018. doi: https://doi.org/10.1088/1361-665X/aaf3f1. 76. Mentink MJA. Measurement of bearing load in unicompartmental knee arthroplasty using an instrumented knee bearing. PhD Thesis 2014. 77. Regulation (EU) 2017/745 of the European Parliament and of the Council of 5 April 2017 on medical devices, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directives 90/385/EEC and 93/42/EEC (Text with EEA relevance.). 78. Kurtz SM. 2 - From Ethylene Gas to UHMWPE Component: The Process of Producing Orthopedic Implants. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 7-20. 79. Scott CEH, Eaton MJ, Nutton RW, Wade FA, Evans SL, Pankaj P. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty. Bone & Joint Research. 2017;6(1):22-30. doi: 10.1302/2046-3758.61.Bjr-2016-0142.R1. 80. Rajamäki A, Niemeläinen M, Junnila M, Lehtovirta L, Karsikas M, Ponkilainen V, et al. Thicker polyethylene inserts (≥ 13 mm) increase the risk for early failure after primary cruciate-retaining total knee arthroplasty (TKA): a single-centre study of 7643 TKAs. Knee Surgery, Sports Traumatology, Arthroscopy. 2023;31(3):1018-1025. doi: 10.1007/s00167-022-07189-8. 81. Muratoglu OK, Bragdon CR. 15 - Highly Cross-Linked and Melted UHMWPE. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 264-273. 82. Spece H, Schachtner JT, MacDonald DW, Klein GR, Mont MA, Lee G-C, et al. Reasons for Revision, Oxidation, and Damage Mechanisms of Retrieved Vitamin E-Stabilized Highly Crosslinked Polyethylene in Total Knee Arthroplasty. The Journal of Arthroplasty. 2019;34(12):3088-3093. doi: https://doi.org/10.1016/j.arth.2019.07.018. 83. Kang JY, Lee YS. Same-Level Fracture of the Tibial Metal Tray and Polyethylene Insert After Total Knee Arthroplasty. Orthopedics. 2016;39(4):e787-789. doi: 10.3928/01477447-20160513-03. PubMed PMID: 27203415. 84. Li AE, Sneag DB, Miller TT, Lipman JD, Padgett DE, Potter HG. MRI of Polyethylene Tibial Inserts in Total Knee Arthroplasty: Normal and Abnormal Appearances. American Journal of Roentgenology. 2016;206(6):1264-1271. doi: 10.2214/AJR.15.15107. 85. Teeter MG, McAuley JP, Naudie DD. Fracture of Two Moderately Cross-Linked Polyethylene Tibial Inserts in a TKR Patient. Case Rep Orthop. 2014;2014:491384-491384. doi: 10.1155/2014/491384. Epub 2014/01/08. PubMed PMID: 24511401. 86. Currier BH, Currier JH, Franklin KJ, Mayor MB, Reinitz SD, Van Citters DW. Comparison of Wear and Oxidation in Retrieved Conventional and Highly Cross-Linked UHMWPE Tibial Inserts. The Journal of Arthroplasty. 2015;30(12):2349-2353. doi: https://doi.org/10.1016/j.arth.2015.06.014. 87. Bei Y, Fregly B. The relationship between contact pressure, insert thickness, and mild wear in total knee replacements. CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES. 2004;6:145-152. 88. Collier JP, Mayor MB, McNamara JL, Surprenant VA, Jensen RE. Analysis of the Failure of 122 Polyethylene Inserts From Uncemented Tibial Knee Components. Clinical Orthopaedics and Related Research®. 1991;273:232-242. PubMed PMID: 00003086-199112000-00034. 89. Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. JBJS. 1986;68(7):1041-1051. PubMed PMID: 00004623-198668070-00010. 90. Pijls BG, Van der Linden-Van der Zwaag HMJ, Nelissen RGHH. Polyethylene thickness is a risk factor for wear necessitating insert exchange. Int Orthop. 2012;36(6):1175-1180. doi: 10.1007/s00264-011-1412-6. 91. Institution TBS. BS EN ISO 21536:2009+A1:2014. Non-active surgical implants. Joint replacement implants. Specific requirements for knee-joint replacement implants. 2009. 92. FDA. Knee Joint Patellofemorotibial and Femorotibial Metal/Polymer Porous-Coated Uncemented Prostheses - Class II Special Controls Guidance Document for Industry and FDA 2003/2018 [accessed 2020 May 14]. Available from: https://www.fda.gov/medical-devices/guidance-documents-medical-devices-and-radiation-emitting-products/knee-joint-patellofemorotibial-and-femorotibial-metalpolymer-porous-coated-uncemented-prostheses. 93. Koh Y-G, Jung K-H, Hong H-T, Kim K-M, Kang K-T. Optimal Design of Patient-Specific Total Knee Arthroplasty for Improvement in Wear Performance. Journal of Clinical Medicine. 2019;8:2023. doi: 10.3390/jcm8112023. 94. MatOrtho. SAIPH Knee System [accessed 2020 January 28]. Available from: https://www.matortho.com/products/saiph-knee-system/. 95. Corin_group. Global APEX Knee™ Reconstruction System [accessed 2020 January 28]. Available from: https://www.coringroup.com/assets/product-resources/apex/GKL-014-Global-Apex-Knee-System-Brochure-REV-0.pdf. 96. Kobayashi H, Mitsugi N, Mochida Y, Taki N, Akamatsu Y, Aratake M, et al. Mid- term results of stryker® scorpio plus mobile bearing total knee arthroplasty. Sports Medicine, Arthroscopy, Rehabilitation, Therapy & Technology. 2012;4(1):38. doi: 10.1186/1758-2555-4-38. 97. Zimmer. Zimmer®NexGen® Trabecular Metal™ Monoblock Tibial Components Surgical Technique Addendum 2012 [accessed 2020 May 15]. Available from: https://www.zimmerbiomet.com/content/dam/zimmer-biomet/medical-professionals/000-surgical-techniques/knee/zimmer-nexgen-trabecular-metal-monoblock-tibial-components-surgical-technique.pdf. 98. Klein GR, Levine HB, Hartzband MA. Removal of a Well-Fixed Trabecular Metal Monoblock Tibial Component. The Journal of Arthroplasty. 2008;23(4):619-622. doi: https://doi.org/10.1016/j.arth.2007.05.004. 99. Biomet. The Oxford® Partial Knee [accessed 2020 January 28]. Available from: http://www.biomet.com/web_accents/biomet_products/oxfordSignature.cfm. 100. MedicalEXPO. Biomet, Vanguard XP [accessed 2020 January 28]. Available from: https://www.medicalexpo.com/prod/biomet/product-74862-695258.html. 101. Conformis. iTotal [accessed 2020 January 28]. Available from: https://www.conformis.com/custom-made-knee-implants/products/itotal/. 102. Harman MK, DesJardins J, Benson L, Banks SA, LaBerge M, Hodge WA. Comparison of polyethylene tibial insert damage from in vivo function and in vitro wear simulation. J Orthop Res. 2009;27(4):540-548. doi: 10.1002/jor.20743. Epub 2008/10/22. PubMed PMID: 18932244. 103. Haider H. 32 - Tribological Assessment of UHMWPE in the Knee. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 599-634. 104. Mendenhall S. 2008 Hip and Knee Implant Review. Orthopedic Network News. 2008 August 10. 105. Bowden AE, Bergström J. 39 - Computer Modeling and Simulation of UHMWPE. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 753-771. 106. Teeter MG, Parikh A, Taylor M, Sprague J, Naudie DD. Wear and Creep Behavior of Total Knee Implants Undergoing Wear Testing. The Journal of Arthroplasty. 2015;30(1):130-134. doi: https://doi.org/10.1016/j.arth.2014.08.001. 107. AMTI. ADL Knee Simulator 6-Station Joint Simulator [accessed 2023 May 07]. Available from: https://www.amti.biz/product/knee-simulator/. 108. ISO. ISO 14243-1:2009+A1:2020. Implants for surgery. Wear of total knee-joint prostheses. Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test. 109. ISO. ISO 14243-3:2014+A1:2020. Implants for surgery. Wear of total knee-joint prostheses. Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test. 110. Abdelgaied A, Fisher J, Jennings LM. A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements. Journal of the Mechanical Behavior of Biomedical Materials. 2018;78:282-291. doi: https://doi.org/10.1016/j.jmbbm.2017.11.022. 111. ASTM F2003-02(2015), Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air. West Conshohocken, PA: ASTM International; 2015. 112. ASTM F2777-16, Standard Test Method for Evaluating Knee Bearing (Tibial Insert) Endurance and Deformation Under High Flexion. West Conshohocken, PA: ASTM International; 2016. 113. EndoLab. [accessed 2020 February 19]. Available from: https://www.endolab.org/default.asp. 114. ASTM F1800-19e1, Standard Practice for Cyclic Fatigue Testing of Metal Tibial Tray Components of Total Knee Joint Replacements. West Conshohocken, PA: ASTM International; 2019. 115. ASTM F2083-12, Standard Specification for Knee Replacement Prosthesis. West Conshohocken, PA: ASTM International; 2012. 116. Villa T, Migliavacca F, Gastaldi D, Colombo M, Pietrabissa R. Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations. Journal of Biomechanics. 2004;37(1):45-53. doi: https://doi.org/10.1016/S0021-9290(03)00255-0. 117. Ahir SP, Blunn GW, Haider H, Walker PS. Evaluation of a testing method for the fatigue performance of total knee tibial trays. Journal of Biomechanics. 1999;32(10):1049-1057. doi: https://doi.org/10.1016/S0021-9290(99)00094-9. 118. Fish J, Belytschko T. Introduction. A First Course in Finite Elements. Chichester: Wiley; 2007. p. 1-9. 119. Anderson AE, Ellis BJ, Weiss JA. Verification, validation and sensitivity studies in computational biomechanics. Computer methods in biomechanics and biomedical engineering. 2007;10(3):171-184. doi: 10.1080/10255840601160484. PubMed PMID: 17558646. 120. Bergmann G, Graichen F, Rohlmann A, Westerhoff P, Heinlein B, Bender A, et al. Design and Calibration of Load Sensing Orthopaedic Implants. Journal of Biomechanical Engineering. 2008;130(2). doi: 10.1115/1.2898831. 121. Pegg EC, Murray DW, Pandit HG, O’Connor JJ, Gill HS. Fracture of mobile unicompartmental knee bearings: A parametric finite element study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2013;227(11):1213-1223. doi: 10.1177/0954411913494326. PubMed PMID: 23940210. 122. Hasenkamp W, Thevenaz N, Villard J, Bertsch A, Arami A, Aminian K, et al. Design and test of a MEMS strain-sensing device for monitoring artificial knee implants. Biomedical Microdevices. 2013;15(5):831-839. doi: 10.1007/s10544-013-9770-z. 123. ASTM F3161-16, Standard Test Method for Finite Element Analysis (FEA) of Metallic Orthopaedic Total Knee Femoral Components under Closing Conditions. West Conshohocken, PA: ASTM International; 2016. 124. ASTM F3334-19, Standard Practice for Finite Element Analysis (FEA) of Metallic Orthopaedic Total Knee Tibial Components. West Conshohocken, PA: ASTM International; 2019. 125. Kurtz SM. 1 - A Primer on UHMWPE. In: Kurtz SM, editor. UHMWPE Biomaterials Handbook (Third Edition). Oxford: William Andrew Publishing; 2016. p. 1-6. 126. ACNIS_INTERNATIONAL. POLYMERS [accessed 2020 06-Jan]. Available from: http://www.acnis-titanium.com/en/polymers/. 127. Medacta. GMK Primary product range [accessed 2020 06-Jan]. Available from: https://www.medacta.com/EN/gmk-primary. 128. Malito LG, Arevalo S, Kozak A, Spiegelberg S, Bellare A, Pruitt L. Material properties of ultra-high molecular weight polyethylene: Comparison of tension, compression, nanomechanics and microstructure across clinical formulations. Journal of the Mechanical Behavior of Biomedical Materials. 2018;83:9-19. doi: https://doi.org/10.1016/j.jmbbm.2018.03.029. 129. Bianchi F, rinaldi S, Quagliana I, Siccardi F. Polyethylene in TKA: do we really need cross-linked polyethylene? MORE Journal. 2011;01. 130. Ansari F, Gludovatz B, Kozak A, Ritchie RO, Pruitt LA. Notch fatigue of ultrahigh molecular weight polyethylene (UHMWPE) used in total joint replacements. Journal of the Mechanical Behavior of Biomedical Materials. 2016;60:267-279. doi: https://doi.org/10.1016/j.jmbbm.2016.02.014. 131. Zheng X, Wu K, Wang J, Ma L, Yu J, Xu J. Mechanical characteristics of medical grade UHMWPE under dynamic compression. Journal of Materials Science: Materials in Medicine. 2019;30(5):50. doi: 10.1007/s10856-019-6254-6. 132. Lu Y-C, Wu C-Y, Chang T-K, Huang C-H, Huang C-H. Elastoplastic behavior of highly cross-linked and vitamin E-stabilized polyethylene – A biomechanical study. Clinical Biomechanics. 2018;59:152-158. doi: https://doi.org/10.1016/j.clinbiomech.2018.09.021. 133. Johnston HE. The Eﬀect of Surgical Alignment and Soft Tissue Constraints on the Kinematics, Contact Pressure and Wear of a Total Knee Replacement. PhD thesis. [PhD thesis]. Leeds: University of Leeds; 2019. 134. Aherwar A, Singh A, Patnaik A. Current and future biocompatibility aspects of biomaterials for hip prosthesis. AIMS Journal. 2016;3:23-43. doi: 10.3934/bioeng.2016.1.23. 135. ABAQUS ducumentation. Contact constraint enforcement methods in Abaqus/Standard. [accessed 2022 Jul 14]. Available from: https://abaqus-docs.mit.edu/2017/English/SIMACAEITNRefMap/simaitn-c-contactconstraints.htm#:~:text=The%20default%20constraint%20enforcement%20method,overclosure%20relationship%20is%20in%20effect. 136. Budynas R, Nisbett K. Shigley's Mechanical Engineering Design. 9th edition: McGraw-Hill Higher Education; 2010. 137. Smith&Nephew. JOURNEY II XR Measurements [accessed 2020 Jun 05]. Available from: https://www.smith-nephew.com/global/assets/pdf/products/surgical/journeyii-xr-specs.pdf. 138. Stryker. RESTORIS® MCK MultiCompartmental Knee System [accessed 2020 Jun 05]. Available from: https://www.strykermeded.com/media/1708/restoris-mck-technical-data-sheet.pdf. 139. Medacta. MOTO® Medial Partial Knee System [accessed 2020 Jun 05]. Available from: https://media.medacta.com/media/moto-specification-guide-9938moto11sg-rev02.pdf. 140. Nabrdalik M, Sobociński M. Numerical analysis of stress distribution generated in spherical polyethylene inserts by knee joint endoprotheses’ sleds %J Polish Journal of Chemical Technology. 2019;21(2):1-5. doi: doi:10.2478/pjct-2019-0012. 141. ABAQUS Analysis User's Manual. ABAQUS Online Documentation: Version 6.6. Section 18.2.1 Classical metal plasticity.2006. 142. Godest AC, Beaugonin M, Haug E, Taylor M, Gregson PJ. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. Journal of Biomechanics. 2002;35(2):267-275. doi: https://doi.org/10.1016/S0021-9290(01)00179-8. 143. Abaqus. Abaqus Analysis User`s Manual 6.10. Chapter 25.1.4 Three-dimensional solid element library [accessed 2023 Jan 03]. Available from: http://130.149.89.49:2080/v6.10/books/usb/default.htm?startat=pt06ch25s01ael03.html. 144. Abaqus. Abaqus Analysis User`s Manual 6.11. Chapter 27.1.1 Solid (continuum) elements [accessed 2023 Jan 03]. Available from: http://130.149.89.49:2080/v6.11/books/usb/default.htm?startat=pt06ch27s01alm01.html. 145. Abaqus. Abaqus Analysis User`s Manual 6.6. Chapter 21.1.4 Section controls [accessed 2023 Jan 03]. Available from: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/usb/default.htm?startat=pt06ch21s01aus90.html. 146. ABAQUS Analysis User's Manual. ABAQUS Online Documentation: Version 6.6-1. Section 29.2.11.2006. 147. Jahani F. Modelling of dynamic edge loading in total hip replacements with ceramic on plyethylene bearings. PhD Thesis. [PhD Thesis]: University of Leeds; 2017. 148. Liu F, Wang M, Wang J, Du W. The influence of frontally flat bearing design on contact mechanics and kinematics in total knee joint replacements. Tribology International. 2019;136:23-30. doi: https://doi.org/10.1016/j.triboint.2019.03.006. 149. Lee K-Y, Pienkowski D. Viscoelastic recovery of creep-deformed ultra-high molecular weight polyethylene (UHMWPE). ASTM special technical publication. 1998;1307:30-36. 150. Drewniak EI, Crisco JJ, Spenciner DB, Fleming BC. Accuracy of circular contact area measurements with thin-film pressure sensors. Journal of Biomechanics. 2007;40(11):2569-2572. doi: https://doi.org/10.1016/j.jbiomech.2006.12.002. 151. Khosravipour I, Pejhan S, Luo Y, Wyss UP. Customized surface-guided knee implant: Contact analysis and experimental test. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2017;232(1):90-100. doi: 10.1177/0954411917744586. 152. Chen P, Colwell C, D’lima D. A Nonlinear Viscoelastic Finite Element Model of Polyethylene. Molecular & Cellular Biomechanics. 2011;8(2):135. 153. Bitter T, Khan I, Marriott T, Lovelady E, Verdonschot N, Janssen D. The effects of manufacturing tolerances and assembly force on the volumetric wear at the taper junction in modular total hip arthroplasty. Computer Methods in Biomechanics and Biomedical Engineering. 2019;22(13):1061-1072. doi: 10.1080/10255842.2019.1627524. 154. Institution BS. BS EN 22768-1:1993, ISO 2768-1:1989. General tolerances. Tolerances for linear and angular dimensions without individual tolerance indications. 1989. 155. OrthoLoad. Standard Loads Knee Joint 2014 [accessed 2020 Nov 05]. Available from: https://orthoload.com/test-loads/standard-loads-knee-joint/. 156. Abaqus. Abaqus Analysis User`s Manual 6.6. Chapter 2.4 Comparison of implicit and explicit procedures [accessed 2023 Feb 17]. Available from: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/gsa/default.htm?startat=ch02s04.html. 157. Abaqus. Abaqus Analysis User`s Manual 6.6. Chapter 3.1 Types of problems suited for ABAQUS/Explicit [accessed 2023 Feb 17]. Available from: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/gsx/default.htm?startat=ch03s01.html. 158. Research Computing at the University of Leeds. ARC Acknowledgement [accessed 2022 Sep 28]. Available from: https://arcdocs.leeds.ac.uk/usage/acknowledgement.html. 159. Research Computing at the University of Leeds. ARC3. Available from: https://arcdocs.leeds.ac.uk/systems/arc3.html. 160. MILLER RH, EDWARDS WB, BRANDON SCE, MORTON AM, DELUZIO KJ. Why Don’t Most Runners Get Knee Osteoarthritis? A Case for Per-Unit-Distance Loads. Medicine & Science in Sports & Exercise. 2014;46(3):572-579. doi: 10.1249/mss.0000000000000135. PubMed PMID: 00005768-201403000-00018. 161. Abaqus. Abaqus Analysis User`s Manual 6.6. Chapter 7. Linear Dynamics 7.1 Introduction [accessed 2023 Feb 24]. Available from: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/gsa/default.htm?startat=ch07s01.html. 162. Abaqus. Abaqus Analysis User`s Manual 6.14. 6.3.2 Implicit dynamic analysis using direct integration [accessed 2023 Jan 03]. Available from: http://130.149.89.49:2080/v6.14/books/usb/default.htm?startat=pt03ch06s03at07.html. 163. Piziali RL, Seering WP, Nagel DA, Schurman DJ. The function of the primary ligaments of the knee in anterior-posterior and medial-lateral motions. Journal of Biomechanics. 1980;13(9):777-784. doi: https://doi.org/10.1016/0021-9290(80)90239-0. 164. Völlner F, Pilsl U, Craiovan B, Zeman F, Schneider M, Wörner M, et al. Stability of knee ligament complex of Thiel-embalmed cadaver compared to in vivo knee. Journal of the Mechanical Behavior of Biomedical Materials. 2017;71:392-396. doi: https://doi.org/10.1016/j.jmbbm.2017.04.009. 165. Markolf K, Mensch J, Amstutz H. Stiffness and laxity of the knee--the contributions of the supporting structures. A quantitative in vitro study. JBJS. 1976;58(5):583-594. PubMed PMID: 00004623-197658050-00001. 166. Haider H, Walker P, DesJardins J, Blunn G. Effects of Patient and Surgical Alignment Variables on Kinematics in TKR Simulation Under Force-Control. Journal of Astm International. 2006;3. doi: 10.1520/JAI100248. 167. Wang X-H, Bi Z, Dong X, Hu S-Y, Xu L-j, Cheng C-K. Increasing the height of the anterior lip on a tibial insert in a posterior stabilized knee prosthesis has little effect on the wear rate. Med Eng Phys. 2021;91:48-53. doi: https://doi.org/10.1016/j.medengphy.2021.03.007. 168. Maag C, Cracaoanu I, Langhorn J, Heldreth M. Total knee replacement wear during simulated gait with mechanical and anatomic alignments. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2021;235(5):515-522. doi: 10.1177/0954411921991269. PubMed PMID: 33522419. 169. D'Lima DD, Steklov N, Fregly BJ, Banks SA, Colwell Jr. CW. In vivo contact stresses during activities of daily living after knee arthroplasty. Journal of Orthopaedic Research. 2008;26(12):1549-1555. doi: https://doi.org/10.1002/jor.20670. 170. Bartel DL, Rawlinson JJ, Burstein AH, Ranawat CS, Flynn WFJ. Stresses in Polyethylene Components of Contemporary Total Knee Replacements. Clinical Orthopaedics and Related Research®. 1995;317:76-82. PubMed PMID: 00003086-199508000-00012. 171. Kurtz SM, Bartel DL, Rimnac CM. Postirradiation Aging Affects Stress and Strain in Polyethylene Components. Clinical Orthopaedics and Related Research®. 1998;350:209-220. PubMed PMID: 00003086-199805000-00029. 172. Mell SP, Fullam S, Wimmer MA, Lundberg HJ. Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2018;232(6):545-552. doi: 10.1177/0954411918770700. PubMed PMID: 29658386. 173. Chen Z, Zhang J, Gao Y, Chen S, Zhang X, Jin Z. Effects of interference assembly of a tibial insert on the tibiofemoral contact mechanics in total knee replacement. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2019;233(9):948-953. doi: 10.1177/0954411919859905. PubMed PMID: 31234760. 174. Schwiesau J, Schilling C, Utzschneider S, Jansson V, Fritz B, Blömer W, et al. Knee wear simulation under conditions of highly demanding daily activities – Influence on an unicompartmental fixed bearing knee design. Med Eng Phys. 2013;35(8):1204-1211. doi: https://doi.org/10.1016/j.medengphy.2012.12.015. 175. Pruitt LA, Ansari F, Kury M, Mehdizah A, Patten EW, Huddlestein J, et al. Clinical trade-offs in cross-linked ultrahigh-molecular-weight polyethylene used in total joint arthroplasty. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2013;101B(3):476-484. doi: https://doi.org/10.1002/jbm.b.32887. 176. Completo A, Fonseca F, Simões JA. Finite Element and Experimental Cortex Strains of the Intact and Implanted Tibia. Journal of Biomechanical Engineering. 2007;129(5):791-797. doi: 10.1115/1.2768382. 177. Oosterom R, van Ostayen RAJ, Antonelli V, Bersee HEN. Effect of Interface Conditions between Ultrahigh Molecular Weight Polyethylene and Polymethyl Methacrylate Bone Cement on the Mechanical Behaviour of Total Shoulder Arthroplasty. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2005;219(6):425-435. doi: 10.1243/095441105x34455. PubMed PMID: 16312102. 178. Shi W, Li XY, Dong H. Improved wear resistance of ultra-high molecular weight polyethylene by plasma immersion ion implantation. Wear. 2001;250(1):544-552. doi: https://doi.org/10.1016/S0043-1648(01)00636-6. 179. Halloran JP, Petrella AJ, Rullkoetter PJ. Explicit finite element modeling of total knee replacement mechanics. Journal of Biomechanics. 2005;38(2):323-331. doi: https://doi.org/10.1016/j.jbiomech.2004.02.046. 180. Willing R, Kim IY. A holistic numerical model to predict strain hardening and damage of UHMWPE under multiple total knee replacement kinematics and experimental validation. Journal of Biomechanics. 2009;42(15):2520-2527. doi: https://doi.org/10.1016/j.jbiomech.2009.07.008. 181. Bischoff JE, Dharia MA, Hertzler JS, Schipper ON. Evaluation of Total Ankle Arthroplasty Using Highly Crosslinked Ultrahigh-Molecular-Weight Polyethylene Subjected to Physiological Loading. Foot & Ankle International. 2019;40(8):880-887. doi: 10.1177/1071100719847645. PubMed PMID: 31091414. 182. Brockett CL, Abdelgaied A, Haythornthwaite T, Hardaker C, Fisher J, Jennings LM. The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2016;230(5):429-439. doi: 10.1177/0954411916645134. PubMed PMID: 27160561. 183. Pandey RM. Approaches to sample size calculation in comparative studies. The Indian Journal of Pediatrics. 1999;66(4):533-538. doi: 10.1007/BF02727163. 184. Jones SR, Carley S, Harrison M. An introduction to power and sample size estimation. Emerg Med J. 2003;20(5):453-458. doi: 10.1136/emj.20.5.453. Epub 2003/09/05. PubMed PMID: 12954688; PubMed Central PMCID: PMCPMC1726174. 185. Rapuri VR, Clarke HD, Spangehl MJ, Beauchamp CP. Five Cases of Failure of the Tibial Polyethylene Insert Locking Mechanism in One Design of Constrained Knee Arthroplasty. The Journal of Arthroplasty. 2011;26(6):976.e921-976.e924. doi: https://doi.org/10.1016/j.arth.2010.07.013. 186. Sanders AP, Raeymaekers B. The effect of polyethylene creep on tibial insert locking screw loosening and back-out in prosthetic knee joints. Journal of the Mechanical Behavior of Biomedical Materials. 2014;38:1-5. doi: https://doi.org/10.1016/j.jmbbm.2014.06.002. 187. von Keudell A, Agrawal K, Rubash HE. Atraumatic Late Screw Loosening of the Tibial Polyethylene Insert Locking Mechanism in a Constrained Knee Arthroplasty: A Case Report. The Orthopaedic Journal at Harvard Medical School. 2016;17:93-98. 188. Vasiljeva K. Ksenija Vasiljeva ORCID 0000-0002-2049-6491 [accessed 2023 Feb 27]. Available from: https://orcid.org/0000-0002-2049-6491. 189. Carpenter T. Thomas Carpenter ORCID 0000-0001-5676-1739 [accessed 2023 Feb 27]. Available from: https://orcid.org/0000-0001-5676-1739. 190. PARALLAX. PLX-DAQ 2020 [updated 2021 Dec 01; accessed 2023 Jan 16]. Available from: https://www.parallax.com/package/plx-daq/. 191. NetDevil. PLX-DAQ version 2 - now with 64 bit support! (and further new features) [Arduino forum]. 2016 [accessed 2023 Jan 16]. Open source software]. Available from: https://forum.arduino.cc/t/plx-daq-version-2-now-with-64-bit-support-and-further-new-features/420628. 192. Rossom Sv, Smith CR, Thelen DG, Vanwanseele B, Assche DV, Jonkers I. Knee Joint Loading in Healthy Adults During Functional Exercises: Implications for Rehabilitation Guidelines. Journal of Orthopaedic & Sports Physical Therapy. 2018;48(3):162-173. doi: 10.2519/jospt.2018.7459. PubMed PMID: 29308697. 193. Arami A, Simoncini M, Atasoy O, Ali S, Hasenkamp W, Bertsch A, et al. Instrumented Knee Prosthesis for Force and Kinematics Measurements. IEEE Transactions on Automation Science and Engineering. 2013;10(3):615-624. doi: 10.1109/TASE.2012.2226030. 194. ISO. ISO 14879-1:2020. Implants for surgery. Total kneejoint prostheses. Determination of endurance properties of knee tibial trays. 195. Ahir SP. Development of clinically relevant testing methods for the fatigue performance for tibial trays. Doctoral thesis.: University College London (University of London); 2004. 196. Kandahari AM, Yang X, Laroche KA, Dighe AS, Pan D, Cui Q. A review of UHMWPE wear-induced osteolysis: the role for early detection of the immune response. Bone Res. 2016;4:16014. doi: 10.1038/boneres.2016.14. Epub 2016/07/29. PubMed PMID: 27468360; PubMed Central PMCID: PMCPMC4941197. 197. Okazaki Y. Effects of fine microstructures and precipitates of laser-sintered Co–28Cr–6Mo alloy femoral components on wear rate of UHMWPE inserts in a knee joint simulator. Journal of the Mechanical Behavior of Biomedical Materials. 2020;112:103998. doi: https://doi.org/10.1016/j.jmbbm.2020.103998. 198. MettlerToledo. Operating Instructions Excellence Plus Analytical Balances XP Models - Part 1 [accessed 2023 Jan 12]. Available from: https://www.mt.com/dam/P5/labtec/02_Analytical_Balances/03_XP/03_Documentations/03_Operating_Instructions/OI_XP_Analytical_Part_1_EN.pdf. 199. Dodge Y. The concise encyclopedia of statistics. Page 427 Pooled Variance: Springer Science & Business Media; 2008. 200. Okazaki Y, Hosoba M, Miura S, Mochizuki T. Effects of knee simulator control method and radiation dose on UHMWPE wear rate, and relationship between wear rate and clinical revision rate in National Joint Registry. Journal of the Mechanical Behavior of Biomedical Materials. 2019;90:182-190. doi: https://doi.org/10.1016/j.jmbbm.2018.09.034. 201. Fisher J, McEwen H, Tipper J, Jennings L, Farrar R, Stone M, et al. Wear-simulation analysis of rotating-platform mobile-bearing knees. Orthopedics. 2006;29(9):S36. 202. Affatato S, Valigi MC, Logozzo S. Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners. Materials. 2017;10(4):364. PubMed PMID: doi:10.3390/ma10040364."],"dcterms:accessrights":["public"],"dc:title":["Mechanical Design Optimisation of a Tibial Insert for use in Instrumented Total Knee Replacement"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Integrated Ph.D and Master"],"person:identifier.orcid":["0000000251334700"]},"updated_at":"2026-11-18T23:24:33Z"}