{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:34063"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:34063","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Fast frequency containment in power systems with volatile inertia","abstract":"This doctoral thesis addresses the critical challenges posed by the integration of renewable energy sources (RESs) into modern power systems, focusing on the impact on frequency stability in the face of volatile inertia. With RESs rapidly penetrating into power grids to achieve global decarbonisation goals, the intermittent nature of these sources introduces operational complexities that demand novel strategies for preserving the active power balance. Traditional frequency control practices, built upon stable inertia contributions, face significant disruptions due to the reduced or absent inertia inherent to RESs. Consequently, the system frequency dynamics become swift and unpredictable, rendering conventional methods of frequency protection and control obsolete. This research unveils a comprehensive methodology for detecting, locating, and estimating the magnitude of loss of generation (LoG) events in power systems characterised by substantial RES integration. Using the superimposed circuit methodology, nodal current injections from RESs are estimated, forming a system of linear equations that pinpoint LoG events by changes in the nodal currents with unparalleled accuracy. This method transcends traditional reliance on frequency measurements and knowledge of system inertia, making it robust and versatile in real-world applications. Central to this research is the exploration of optimal fast frequency containment (OFFC), which consists of active power injections from RESs to swiftly arrest frequency deviations resulting from LoG events. A new paradigm emerges for OFFC, strategically decomposing the frequency response into transient and steady-state deviations. This approach yields an optimal allocation of power resources to effectively counteract LoG events. Contrary to conventional step-function injections, the proposed methodology ensures that transient deviations are prioritised, thereby conserving energy resources and minimising the time required for frequency to be recovered within statutory limits. The allocation of resources for correcting steady-state deviations subsequently follows if resources are available after mitigating the transient deviation, promoting the preservation of steam turbines' lifespan. In conclusion, this research highlights the critical intersections between RES integration, frequency stability, and LoG event dynamics. By introducing pioneering methodologies and challenging established assumptions, this thesis contributes to the evolution of power grid management strategies in an era of escalating renewable energy adoption. The insights derived bridge theoretical discourse with practical implications, empowering power systems to effectively navigate the complexities of renewable energy integration while ensuring resilience and stability.","abstract_html":"This doctoral thesis addresses the critical challenges posed by the integration of renewable energy sources (RESs) into modern power systems, focusing on the impact on frequency stability in the face of volatile inertia. With RESs rapidly penetrating into power grids to achieve global decarbonisation goals, the intermittent nature of these sources introduces operational complexities that demand novel strategies for preserving the active power balance. Traditional frequency control practices, built upon stable inertia contributions, face significant disruptions due to the reduced or absent inertia inherent to RESs. Consequently, the system frequency dynamics become swift and unpredictable, rendering conventional methods of frequency protection and control obsolete. This research unveils a comprehensive methodology for detecting, locating, and estimating the magnitude of loss of generation (LoG) events in power systems characterised by substantial RES integration. Using the superimposed circuit methodology, nodal current injections from RESs are estimated, forming a system of linear equations that pinpoint LoG events by changes in the nodal currents with unparalleled accuracy. This method transcends traditional reliance on frequency measurements and knowledge of system inertia, making it robust and versatile in real-world applications. Central to this research is the exploration of optimal fast frequency containment (OFFC), which consists of active power injections from RESs to swiftly arrest frequency deviations resulting from LoG events. A new paradigm emerges for OFFC, strategically decomposing the frequency response into transient and steady-state deviations. This approach yields an optimal allocation of power resources to effectively counteract LoG events. Contrary to conventional step-function injections, the proposed methodology ensures that transient deviations are prioritised, thereby conserving energy resources and minimising the time required for frequency to be recovered within statutory limits. The allocation of resources for correcting steady-state deviations subsequently follows if resources are available after mitigating the transient deviation, promoting the preservation of steam turbines&#x27; lifespan. In conclusion, this research highlights the critical intersections between RES integration, frequency stability, and LoG event dynamics. By introducing pioneering methodologies and challenging established assumptions, this thesis contributes to the evolution of power grid management strategies in an era of escalating renewable energy adoption. The insights derived bridge theoretical discourse with practical implications, empowering power systems to effectively navigate the complexities of renewable energy integration while ensuring resilience and stability.","abstract_has_math":false,"creators":["Sanchez Cortes, Jesus"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Azizi, Sadegh","Li, Kang"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-12","date_published":"2023-12","updated_at":"2026-11-18T23:25:06Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["2019-000021-01EXTF-00253"],"render_values":[{"text":"2019-000021-01EXTF-00253","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000347060599"],"render_values":[{"text":"0000-0003-4706-0599","href":"https://orcid.org/0000-0003-4706-0599","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/34063/1/SanchezCortes_J_EEE_PhD_2023.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A34063","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Azizi, Sadegh","Li, Kang"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["CONACyT Mexico"]},{"key":"dc:creator","label":"Author","values":["Sanchez Cortes, Jesus"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000347060599"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-12"]},{"key":"dc:date.issued","label":"Date","values":["2023-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Electronic & Electrical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/34063/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] H. Kirkham, W. Dickerson, and A. Phadke, “Defining power system frequency,” in 2018 IEEE Power Energy Society General Meeting (PESGM), 2018, pp. 1–5. [2] P. Kundur, J. Paserba, V. Ajjarapu, G. Andersson, A. Bose, C. Canizares, N. Hatziargyriou, D. Hill, A. Stankovic, C. Taylor, T. Van Cutsem, and V. Vittal, “Definition and classification of power system stability ieee/cigre joint task force on stability terms and definitions,” IEEE Transactions on Power Systems, vol. 19, no. 3, pp. 1387–1401, 2004. [3] O. Elgerd, “Control of electric power systems,” IEEE Control Systems Magazine, vol. 1, no. 2, pp. 4–16, 1981. [4] A. Gomez-Exposito, A. J. Conejo, and C. Ca˜nizares, Electric energy systems: analysis and operation. CRC press, 2018. [5] F. Milano, F. D¨orfler, G. Hug, D. J. Hill, and G. Verbi¨A, “Foundations and challenges of low-inertia systems (invited paper),” in 2018 Power Systems Computation Conference (PSCC), 2018, pp. 1–25. [6] D. Zografos and M. Ghandhari, “Power system inertia estimation by approaching load power change after a disturbance,” in 2017 IEEE Power & Energy Society General Meeting. IEEE, 2017, pp. 1–5. [7] N. G. ESO, “The enhanced frequency control capability (EFCC) project, closing down report,” 2019. [8] MIGRATE, “Development and tests of new protection solutions when reaching 100pe penetration,” Dec 2018. [9] P. Kundur, Power System Stability and Control. McGraw-Hill, 1994. [10] ENTSO-E, “Future system inertia,” Feb 2018. [11] Y. Zhang, P. Markham, T. Xia, L. Chen, Y. Ye, Z. Wu, Z. Yuan, L. Wang, J. Bank, J. Burgett et al., “Wide-area frequency monitoring network (fnet) architecture and applications,” IEEE Transactions on smart grid, vol. 1, no. 2, pp. 159–167, 2010. [12] P. M. Anderson, Power system protection. John Wiley & Sons IEEE Press, 1999. [13] V. V. Terzija, “Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation,” IEEE Transactions on Power Systems, vol. 21, no. 3, pp. 1260–1266, 2006. [14] P. Tielens and D. Van Hertem, “The relevance of inertia in power systems,” Renewable and sustainable energy reviews, vol. 55, pp. 999–1009, 2016. [15] M. Sun, G. Liu, M. Popov, V. Terzija, and S. Azizi, “Underfrequency load shedding using locally estimated rocof of the center of inertia,” IEEE Transactions on Power Systems, vol. 36, no. 5, pp. 4212–4222, 2021. [16] J. Dong, J. Zuo, L. Wang, K. S. Kook, I.-Y. Chung, Y. Liu, S. Affare, B. Rogers, and M. Ingram, “Analysis of power system disturbances based on wide-area frequency measurements,” in 2007 IEEE Power Engineering Society General Meeting. IEEE, 2007, pp. 1–8. [17] A. Bykhovsky and J. H. Chow, “Power system disturbance identification from recorded dynamic data at the northfield substation,” International journal of electrical power & energy systems, vol. 25, no. 10, pp. 787–795, 2003. [18] J. Bank et al., “Generator trip identification using wide-area measurements and historical data analysis, psce 2006,” 2006. [19] W. Li, J. Tang, J. Ma, and Y. Liu, “Online detection of start time and location for hypocenter in north america power grid,” IEEE Transactions on Smart Grid, vol. 1, no. 3, pp. 253–260, 2010. [20] K. Mei, S. M. Rovnyak, and C.-M. Ong, “Clustering-based dynamic event location using wide-area phasor measurements,” IEEE Transactions on Power Systems, vol. 23, no. 2, pp. 673–679, 2008. [21] J. S. Thorp, C. E. Seyler, and A. G. Phadke, “Electromechanical wave propagation in large electric power systems,” IEEE Transactions on Circuits and Systems I: Fundamental Theory and Applications, vol. 45, no. 6, pp. 614–622, 1998. [22] T. Xia, H. Zhang, R. Gardner, J. Bank, J. Dong, J. Zuo, Y. Liu, L. Beard, P. Hirsch, G. Zhang et al., “Wide-area frequency based event location estimation,” in 2007 IEEE Power Engineering Society General Meeting. IEEE, 2007, pp. 1–7. [23] G. Zheng, Y. Liu, and G. Radman, “Wide area frequency based generation trip event location estimation,” in 2012 IEEE Power and Energy Society General Meeting. IEEE, 2012, pp. 1–6. [24] W.-T. Li, C.-K. Wen, J.-C. Chen, K.-K. Wong, J.-H. Teng, and C. Yuen, “Location identification of power line outages using pmu measurements with bad data,” IEEE Transactions on Power Systems, vol. 31, no. 5, pp. 3624–3635, 2015. [25] G. Frigo, A. Derviˇskadi´c, Y. Zuo, and M. Paolone, “Pmu-based rocof measurements: Uncertainty limits and metrological significance in power system applications,” IEEE Transactions on Instrumentation and Measurement, vol. 68, no. 10, pp. 3810–3822, 2019. [26] U. Rudez and R. Mihalic, “Analysis of underfrequency load shedding using a frequency gradient,” IEEE transactions on power delivery, vol. 26, no. 2, pp. 565–575, 2009. [27] H. Zhang, F. Shi, Y. Liu, and V. Terzija, “Adaptive online disturbance location considering anisotropy of frequency propagation speeds,” IEEE Transactions on Power Systems, vol. 31, no. 2, pp. 931–941, 2015. [28] D.-I. Kim, A. White, and Y.-J. Shin, “Pmu-based event localization technique for wide-area power system,” IEEE Transactions on Power Systems, vol. 33, no. 6, pp. 5875–5883, 2018. [29] S. M. Rovnyak and K. Mei, “Dynamic event detection and location using wide area phasor measurements,” European Transactions on Electrical Power, vol. 21, no. 4, pp. 1589–1599, 2011. [30] R. Azizipanah-Abarghooee, M. Malekpour, M. Paolone, and V. Terzija, “A new approach to the online estimation of the loss of generation size in power systems,” IEEE Transactions on Power Systems, vol. 34, no. 3, pp. 2103–2113, 2018. [31] N. Shams, P. Wall, and V. Terzija, “Active power imbalance detection, size and location estimation using limited pmu measurements,” IEEE Transactions on Power Systems, vol. 34, no. 2, pp. 1362–1372, 2018. [32] S. Azizi, M. R. Jegarluei, A. S. Dobakhshari, G. Liu, and V. Terzija, “Wide-area identification of the size and location of loss of generation events by sparse pmus,” IEEE Transactions on Power Delivery, vol. 36, no. 4, pp. 2397–2407, 2020. [33] G. G. Solutions, “Enhanced frequency control capability (EFCC), optimisation detailed design,” Jan 2016. [Online]. Available: https://www.nationalgrideso. com/document/135981/download [34] Y. Cheng, R. Azizipanah-Abarghooee, S. Azizi, L. Ding, and V. Terzija, “Smart frequency control in low inertia energy systems based on frequency response techniques: A review,” Applied Energy, vol. 279, p. 115798, 2020. [35] W. He, X. Yuan, and J. Hu, “Inertia provision and estimation of PLL-based dfig wind turbines,” IEEE Transactions on power systems, vol. 32, no. 1, pp. 510–521, 2016. [36] L. Harnefors, M. Schweizer, J. Kukkola, M. Routimo, M. Hinkkanen, and X. Wang, “Generic PLL-based grid-forming control,” IEEE Transactions on Power Electronics, vol. 37, no. 2, pp. 1201–1204, 2021. [37] X. Guo, D. Zhu, J. Hu, X. Zou, Y. Kang, and J. M. Guerrero, “Inertial PLL of grid-connected converter for fast frequency support,” CSEE Journal of Power and Energy Systems, 2022. [38] C. Zhang, E. Rakhshani, N. Veerakumar, J. L. R. Torres, and P. Palensky, “Modeling and optimal tuning of hybrid ESS supporting fast active power regulation of ully decoupled wind power generators,” IEEE Access, vol. 9, pp. 46 409–46 421, 2021. [39] J. Lee, S. Jeong, H. Kim, Y. Yoo, S. Jung, M. Yoon, and G. Jang, “Analytical approach for fast frequency response control of VSC HVDC,” IEEE Access, vol. 9, pp. 91 303–91 313, 2021. [40] M. Kabsha and Z. H. Rather, “A new control scheme for fast frequency support from HVDC connected offshore wind farm in low-inertia system,” IEEE Transactions on Sustainable Energy, vol. 11, no. 3, pp. 1829–1837, 2019. [41] K. Jose, O. Adeuyi, J. Liang, and C. E. Ugalde-Loo, “Coordination of fast frequency support from multi-terminal HVDC grids,” in 2018 IEEE international energy conference (ENERGYCON). IEEE, 2018, pp. 1–6. [42] O. Stanojev, U. Markovic, E. Vrettos, P. Aristidou, D. Callaway, and G. Hug, “Enhanced MPC for fast frequency control in inverter-dominated power systems,” in 2020 International Conference on Smart Energy Systems and Technologies (SEST). IEEE, 2020, pp. 1–6. [43] D. Yang, L. Hua, and X. Zhang, “Fast frequency support of a DFIG based on overspeed de-loaded curve,” in 2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia). IEEE, 2021, pp. 1314–1318. [44] M. Kheshti, S. Lin, X. Zhao, L. Ding, M. Yin, and V. Terzija, “Gaussian distribution-based inertial control of wind turbine generators for fast frequency response in low inertia systems,” IEEE Transactions on Sustainable Energy, vol. 13, no. 3, pp. 1641–1653, 2022. [45] X. Zhao, Y. Xue, and X.-P. Zhang, “Fast frequency support from wind turbine systems by arresting frequency nadir close to settling frequency,” IEEE Open Access Journal of Power and Energy, vol. 7, pp. 191–202, 2020. [46] G. Xu, L. Xu, and J. Morrow, “System frequency support using wind turbine kinetic energy and energy storage system,” in 2nd IET Renewable Power Generation Conference (RPG 2013). IET, 2013. [47] K. Sun, K.-J. Li, W. Bao, Z. Liu, M. Wang, W.-J. Lee et al., “Frequency compensation control strategy of energy storage in the wind-energy storage hybrid system for improving frequency response performance,” in 2019 IEEE Industry Applications Society Annual Meeting. IEEE, 2019, pp. 1–8. [48] W. Liu, G. Geng, Q. Jiang, H. Fan, and J. Yu, “Model-free fast frequency control support with energy storage system,” IEEE Transactions on Power Systems, vol. 35, no. 4, pp. 3078–3086, 2019. [49] Y. Yoo, S. Jung, and G. Jang, “Dynamic inertia response support by energy storage system with renewable energy integration substation,” Journal of Modern Power Systems and Clean Energy, vol. 8, no. 2, pp. 260–266, 2019. [50] W. Bao, L. Ding, Z. Liu, G. Zhu, M. Kheshti, Q.Wu, and V. Terzija, “Analytically derived fixed termination time for stepwise inertial control of wind turbines-part i: Analytical derivation,” International Journal of Electrical Power & Energy Systems, vol. 121, p. 106120, 2020. [51] Y. Guo, W. Bao, L. Ding, Z. Liu, M. Kheshti, Q. Wu, and V. Terzija, “Analytically derived fixed termination time for stepwise inertial control of wind turbines part ii: Application strategy,” International Journal of Electrical Power & Energy Systems, vol. 121, p. 106106, 2020. [52] P. Anderson and M. Mirheydar, “A low-order system frequency response model,” IEEE Transactions on Power Systems, vol. 5, no. 3, pp. 720–729, 1990. [53] N. G. ESO, “Dynamic containment response balancing service, test guidance for providers,” Jun 2022. [54] ——, The grid code, Issue 6, Revision 16. Great Britain, 2023. [55] J. J. Grainger and W. D. Stevenson Jr, Power system analysis. McGraw-Hill series in electrical and computer engineering, 1994. [56] W. C. New and W. C. New, Load shedding, load restoration and generator protection using solid-state and electromechanical underfrequency relays. General Electric Company, Power Systems Management, 1974. [57] J. D. Glover, M. S. Sarma, and T. Overbye, Power system analysis & design, SI version. Cengage Learning, 2012. [58] A. Ulbig, T. S. Borsche, and G. Andersson, “Impact of low rotational inertia on power system stability and operation,” IFAC Proceedings Volumes, vol. 47, no. 3, pp. 7290–7297, 2014. [59] U. Rudez and R. Mihalic, “Wams-based underfrequency load shedding with shortterm frequency prediction,” IEEE Transactions on Power Delivery, vol. 31, no. 4, pp. 1912–1920, 2015. [60] S. Azizi, M. Sun, G. Liu, and V. Terzija, “Local frequency-based estimation of the rate of change of frequency of the center of inertia,” IEEE Transactions on Power Systems, vol. 35, no. 6, pp. 4948–4951, 2020. [61] J. S. Cortes and D. R. Romero, “Esquemas dinamicos de tiro de carga por baja frecuencia mediante logica difusa,” in 27 Reunion Internacional de Verano de Potencia, Aplicaciones Industriales y Exposicion Industrial (RVP-AI). IEEE, 2014, pp. 1–8 SIS–17, PON–89. [62] P. Warren, “A review of demand-side management policy in the UK,” Renewable and Sustainable Energy Reviews, vol. 29, pp. 941–951, 2014. [63] H. Bevrani, Robust power system frequency control. Springer, 2014, vol. 4. [64] A. J. Wood, B. F. Wollenberg, and G. B. Shebl´e, Power generation, operation, and control. John Wiley & Sons, 2013. [65] C. Rowland, D. Smaha, and J. Pope, “Coordination of load conservation with turbine-generator underfrequency protection,” IEEE Transactions on Power Apparatus and Systems, no. 3, pp. 1137–1150, 1980. [66] Y. Omar, I. Abidin, S. Yusof, H. Hashim, and H. A. Rashid, “Under frequency load shedding (ufls): Principles and implementation,” in 2010 IEEE International Conference on Power and Energy. IEEE, 2010, pp. 414–419. [67] J. Sanchez Cortes, “Diseño de esquemas de tiro de carga por baja frecuencia utilizando tecnicas inteligentes,” MSc thesis, 2014. [68] M. Abedini, M. Sanaye-Pasand, and S. Azizi, “Adaptive load shedding scheme to preserve the power system stability following large disturbances,” IET Generation, Transmission & Distribution, vol. 8, no. 12, pp. 2124–2133, 2014. [69] RielloUPS, “The blackout report: what happens when there is no power?” 2019. [70] T. S. Borsche, T. Liu, and D. J. Hill, “Effects of rotational inertia on power system damping and frequency transients,” in 2015 54th IEEE conference on decision and control (CDC). IEEE, 2015, pp. 5940–5946. [71] I. P. P. S. R. Committee et al., “Ieee guide for abnormal frequency protection for power generating plants,” IEEE Std C37. 106-2003 (Revision of ANSI/IEEE C37. 106-1987), pp. 0 1–34, 2004. [72] J. Berdy, P. Brown, and L. Goff, “Protection of steam turbine generators during abnormal frequency conditions,” General Electric Company, Schenectady, New York, 1974. [73] R. Warner, T. Dillman, and M. Baldwin, “Off-frequency turbine-generator unit operation,” in Proc. Am. Power Conf.;(United States), vol. 38, 1976. [74] P. K. Pathak and A. R. Gupta, “Battery energy storage system,” in 2018 4th International Conference on Computational Intelligence & Communication Technology (CICT). IEEE, 2018, pp. 1–9. [75] M. Kheshti, L. Ding, W. Bao, M. Yin, Q. Wu, and V. Terzija, “Toward intelligent inertial frequency participation of wind farms for the grid frequency control,” IEEE Transactions on Industrial Informatics, vol. 16, no. 11, pp. 6772–6786, 2019. [76] L. Ruttledge, N. W. Miller, J. O’Sullivan, and D. Flynn, “Frequency response of power systems with variable speed wind turbines,” IEEE transactions on Sustainable Energy, vol. 3, no. 4, pp. 683–691, 2012. [77] M. Garmroodi, G. Verbiˇc, and D. J. Hill, “Frequency support from wind turbine generators with a time-variable droop characteristic,” IEEE Transactions on Sustainable Energy, vol. 9, no. 2, pp. 676–684, 2017. [78] F. D´ıaz-Gonz´alez, M. Hau, A. Sumper, and O. Gomis-Bellmunt, “Participation of wind power plants in system frequency control: Review of grid code requirements and control methods,” Renewable and Sustainable Energy Reviews, vol. 34, pp. 551–564, 2014. [79] J. Van de Vyver, J. D. De Kooning, B. Meersman, L. Vandevelde, and T. L. Vandoorn, “Droop control as an alternative inertial response strategy for the synthetic inertia on wind turbines,” IEEE Transactions on Power Systems, vol. 31, no. 2, pp. 1129–1138, 2015. [80] X. Zhang, X. Zha, S. Yue, and Y. Chen, “A frequency regulation strategy for wind power based on limited over-speed de-loading curve partitioning,” IEEE Access, vol. 6, pp. 22 938–22 951, 2018. [81] W. Bao, Q. Wu, L. Ding, S. Huang, F. Teng, and V. Terzija, “Synthetic inertial control of wind farm with bess based on model predictive control,” IET Renewable Power Generation, vol. 14, no. 13, pp. 2447–2455, 2020. [82] M. Dreidy, H. Mokhlis, and S. Mekhilef, “Inertia response and frequency control techniques for renewable energy sources: A review,” Renewable and sustainable energy reviews, vol. 69, pp. 144–155, 2017. [83] C. Rahmann, J. Jara, and M. Salles, “Effects of inertia emulation in modern wind parks on isolated power systems,” in 2015 IEEE Power & Energy Society General Meeting. IEEE, 2015, pp. 1–5. [84] W. Bao, L. Ding, S. Yin, K. Wang, and V. Terzija, “Active rotor speed protection for dfig synthetic inertia control,” 2016. [85] R. Eriksson, N. Modig, and K. Elkington, “Synthetic inertia versus fast frequency response: a definition,” IET renewable power generation, vol. 12, no. 5, pp. 507– 514, 2018. [86] U. Energy, “Pathways for the gb electricity sector to 2030,” Full Report, 2016. [87] N. Mendis, K. M. Muttaqi, and S. Perera, “Management of batterysupercapacitor hybrid energy storage and synchronous condenser for isolated operation of pmsg based variable-speed wind turbine generating systems,” IEEE Transactions on smart grid, vol. 5, no. 2, pp. 944–953, 2014. [88] S. Azizi and M. Sanaye-Pasand, “From available synchrophasor data to shortcircuit fault identity: Formulation and feasibility analysis,” IEEE Transactions on Power Systems, vol. 32, no. 3, pp. 2062–2071, 2016. [89] K. Jia, Z. Yang, Y. Fang, T. Bi, and M. Sumner, “Influence of inverter-interfaced renewable energy generators on directional relay and an improved scheme,” IEEE Transactions on Power Electronics, vol. 34, no. 12, pp. 11 843–11 855, 2019. [90] J. S. Cortes, M. R. Jegarluei, P. Aristidou, K. Li, and S. Azizi, “Size/location estimation for loss of generation events in power systems with high penetration of renewables,” Electric Power Systems Research, vol. 219, p. 109242, 2023. [91] A. S. Dobakhshari, S. Azizi, M. Paolone, and V. Terzija, “Ultra fast linear state estimation utilizing scada measurements,” IEEE Transactions on Power Systems, vol. 34, no. 4, pp. 2622–2631, 2019. [92] C. D. Meyer, Matrix analysis and applied linear algebra. SIAM, 2000. [93] T. T. GmbH, Grid code-High and extra high voltage, 2017. [94] R. D. Zimmerman, C. E. Murillo-S´anchez, and D. Gan, MATPOWER: A MATLAB power system simulation package. Manual, Power Systems Engineering Research Center, Ithaca NY, 2007, vol. 3.2. [95] S. Azizi, A. S. Dobakhshari, S. A. N. Sarmadi, and A. M. Ranjbar, “Optimal PMU placement by an equivalent linear formulation for exhaustive search,” IEEE Transactions on Smart Grid, vol. 3, no. 1, pp. 174–182, 2012. [96] S. M. for Power SystemsWorking Group et al., “IEEE standard for synchrophasor measurements for power systems,” IEEE Std C, vol. 37, pp. 1–61. [97] A. Abur and A. G. Exposito, Power system state estimation: theory and implementation. CRC press, 2004. [98] S. Sarri, M. Pignati, P. Romano, L. Zanni, and M. Paolone, “A hardware-in-theloop test platform for the performance assessment of a PMU-based real-time state estimator for active distribution networks,” in 2015 IEEE Eindhoven PowerTech. IEEE, 2015, pp. 1–6. [99] A. G. Phadke and J. S. Thorp, Computer relaying for power systems. John Wiley & Sons, 2009. [100] F. C. Schweppe and J. Wildes, “Power system static-state estimation, part I: Exact model,” IEEE Transactions on Power Apparatus and Systems, vol. PAS- 89, no. 1, pp. 120–125, 1970. [101] J. Sanchez Cortes, M. Rezaei Jegarluei, and S. Azizi, “Targeted fast frequency response by decomposing frequency into transient and steady-state deviations,” in 2023 International Conference on Energy Technologies for Future Grids (ETFG). IEEE, 2023. [102] R. Bracewell, The Fourier transform and its applications. McGraw-Hill, 1986. [103] A. Aksoy and M. Martelli, “Mixed partial derivatives and Fubini’s theorem,” The College Mathematics Journal, vol. 33, no. 2, pp. 126–130, 2002. [104] N. Chaudhuri, B. Chaudhuri, R. Majumder, and A. Yazdani, Multi-terminal direct-current grids: Modeling, analysis, and control. John Wiley & Sons, 2014. [105] P. Rodr´ıguez, J. Pou, J. Bergas, J. I. Candela, R. P. Burgos, and D. Boroyevich, “Decoupled double synchronous reference frame PLL for power converters control,” IEEE Transactions on Power Electronics, vol. 22, no. 2, pp. 584–592, 2007. [106] M. R. Jegarluei, P. Aristidou, and S. Azizi, “Wide-area backup protection against asymmetrical faults in the presence of renewable energy sources,” International Journal of Electrical Power & Energy Systems, vol. 144, p. 108528, 2023. [107] K. Ma, W. Chen, M. Liserre, and F. Blaabjerg, “Power controllability of a threephase converter with an unbalanced ac source,” IEEE Transactions on Power Electronics, vol. 30, no. 3, pp. 1591–1604, 2014."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["2019-000021-01EXTF-00253"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/34063/1/SanchezCortes_J_EEE_PhD_2023.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This doctoral thesis addresses the critical challenges posed by the integration of renewable energy sources (RESs) into modern power systems, focusing on the impact on frequency stability in the face of volatile inertia. With RESs rapidly penetrating into power grids to achieve global decarbonisation goals, the intermittent nature of these sources introduces operational complexities that demand novel strategies for preserving the active power balance. Traditional frequency control practices, built upon stable inertia contributions, face significant disruptions due to the reduced or absent inertia inherent to RESs. Consequently, the system frequency dynamics become swift and unpredictable, rendering conventional methods of frequency protection and control obsolete. This research unveils a comprehensive methodology for detecting, locating, and estimating the magnitude of loss of generation (LoG) events in power systems characterised by substantial RES integration. Using the superimposed circuit methodology, nodal current injections from RESs are estimated, forming a system of linear equations that pinpoint LoG events by changes in the nodal currents with unparalleled accuracy. This method transcends traditional reliance on frequency measurements and knowledge of system inertia, making it robust and versatile in real-world applications. Central to this research is the exploration of optimal fast frequency containment (OFFC), which consists of active power injections from RESs to swiftly arrest frequency deviations resulting from LoG events. A new paradigm emerges for OFFC, strategically decomposing the frequency response into transient and steady-state deviations. This approach yields an optimal allocation of power resources to effectively counteract LoG events. Contrary to conventional step-function injections, the proposed methodology ensures that transient deviations are prioritised, thereby conserving energy resources and minimising the time required for frequency to be recovered within statutory limits. The allocation of resources for correcting steady-state deviations subsequently follows if resources are available after mitigating the transient deviation, promoting the preservation of steam turbines' lifespan. In conclusion, this research highlights the critical intersections between RES integration, frequency stability, and LoG event dynamics. By introducing pioneering methodologies and challenging established assumptions, this thesis contributes to the evolution of power grid management strategies in an era of escalating renewable energy adoption. The insights derived bridge theoretical discourse with practical implications, empowering power systems to effectively navigate the complexities of renewable energy integration while ensuring resilience and stability."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Fast frequency containment in power systems with volatile inertia"]}]}],"canonical_facts":{"dc:contributor.advisor":["Azizi, Sadegh","Li, Kang"],"dc:contributor.sponsor":["CONACyT Mexico"],"dc:creator":["Sanchez Cortes, Jesus"],"dc:date":["2023-12"],"dc:date.issued":["2023-12"],"dc:description.abstract":["This doctoral thesis addresses the critical challenges posed by the integration of renewable energy sources (RESs) into modern power systems, focusing on the impact on frequency stability in the face of volatile inertia. With RESs rapidly penetrating into power grids to achieve global decarbonisation goals, the intermittent nature of these sources introduces operational complexities that demand novel strategies for preserving the active power balance. Traditional frequency control practices, built upon stable inertia contributions, face significant disruptions due to the reduced or absent inertia inherent to RESs. Consequently, the system frequency dynamics become swift and unpredictable, rendering conventional methods of frequency protection and control obsolete. This research unveils a comprehensive methodology for detecting, locating, and estimating the magnitude of loss of generation (LoG) events in power systems characterised by substantial RES integration. Using the superimposed circuit methodology, nodal current injections from RESs are estimated, forming a system of linear equations that pinpoint LoG events by changes in the nodal currents with unparalleled accuracy. This method transcends traditional reliance on frequency measurements and knowledge of system inertia, making it robust and versatile in real-world applications. Central to this research is the exploration of optimal fast frequency containment (OFFC), which consists of active power injections from RESs to swiftly arrest frequency deviations resulting from LoG events. A new paradigm emerges for OFFC, strategically decomposing the frequency response into transient and steady-state deviations. This approach yields an optimal allocation of power resources to effectively counteract LoG events. Contrary to conventional step-function injections, the proposed methodology ensures that transient deviations are prioritised, thereby conserving energy resources and minimising the time required for frequency to be recovered within statutory limits. The allocation of resources for correcting steady-state deviations subsequently follows if resources are available after mitigating the transient deviation, promoting the preservation of steam turbines' lifespan. In conclusion, this research highlights the critical intersections between RES integration, frequency stability, and LoG event dynamics. By introducing pioneering methodologies and challenging established assumptions, this thesis contributes to the evolution of power grid management strategies in an era of escalating renewable energy adoption. The insights derived bridge theoretical discourse with practical implications, empowering power systems to effectively navigate the complexities of renewable energy integration while ensuring resilience and stability."],"dc:format":["text"],"dc:identifier.grantnumber":["2019-000021-01EXTF-00253"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/34063/1/SanchezCortes_J_EEE_PhD_2023.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Electronic & Electrical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/34063/"],"dc:relation.references":["[1] H. Kirkham, W. Dickerson, and A. Phadke, “Defining power system frequency,” in 2018 IEEE Power Energy Society General Meeting (PESGM), 2018, pp. 1–5. [2] P. Kundur, J. Paserba, V. Ajjarapu, G. Andersson, A. Bose, C. Canizares, N. Hatziargyriou, D. Hill, A. Stankovic, C. Taylor, T. Van Cutsem, and V. Vittal, “Definition and classification of power system stability ieee/cigre joint task force on stability terms and definitions,” IEEE Transactions on Power Systems, vol. 19, no. 3, pp. 1387–1401, 2004. [3] O. Elgerd, “Control of electric power systems,” IEEE Control Systems Magazine, vol. 1, no. 2, pp. 4–16, 1981. [4] A. Gomez-Exposito, A. J. Conejo, and C. Ca˜nizares, Electric energy systems: analysis and operation. CRC press, 2018. [5] F. Milano, F. D¨orfler, G. Hug, D. J. Hill, and G. Verbi¨A, “Foundations and challenges of low-inertia systems (invited paper),” in 2018 Power Systems Computation Conference (PSCC), 2018, pp. 1–25. [6] D. Zografos and M. Ghandhari, “Power system inertia estimation by approaching load power change after a disturbance,” in 2017 IEEE Power & Energy Society General Meeting. IEEE, 2017, pp. 1–5. [7] N. G. ESO, “The enhanced frequency control capability (EFCC) project, closing down report,” 2019. [8] MIGRATE, “Development and tests of new protection solutions when reaching 100pe penetration,” Dec 2018. [9] P. Kundur, Power System Stability and Control. McGraw-Hill, 1994. [10] ENTSO-E, “Future system inertia,” Feb 2018. [11] Y. Zhang, P. Markham, T. Xia, L. Chen, Y. Ye, Z. Wu, Z. Yuan, L. Wang, J. Bank, J. Burgett et al., “Wide-area frequency monitoring network (fnet) architecture and applications,” IEEE Transactions on smart grid, vol. 1, no. 2, pp. 159–167, 2010. [12] P. M. Anderson, Power system protection. John Wiley & Sons IEEE Press, 1999. [13] V. V. Terzija, “Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation,” IEEE Transactions on Power Systems, vol. 21, no. 3, pp. 1260–1266, 2006. [14] P. Tielens and D. Van Hertem, “The relevance of inertia in power systems,” Renewable and sustainable energy reviews, vol. 55, pp. 999–1009, 2016. [15] M. Sun, G. Liu, M. Popov, V. Terzija, and S. Azizi, “Underfrequency load shedding using locally estimated rocof of the center of inertia,” IEEE Transactions on Power Systems, vol. 36, no. 5, pp. 4212–4222, 2021. [16] J. Dong, J. Zuo, L. Wang, K. S. Kook, I.-Y. Chung, Y. Liu, S. Affare, B. Rogers, and M. Ingram, “Analysis of power system disturbances based on wide-area frequency measurements,” in 2007 IEEE Power Engineering Society General Meeting. IEEE, 2007, pp. 1–8. [17] A. Bykhovsky and J. H. Chow, “Power system disturbance identification from recorded dynamic data at the northfield substation,” International journal of electrical power & energy systems, vol. 25, no. 10, pp. 787–795, 2003. [18] J. Bank et al., “Generator trip identification using wide-area measurements and historical data analysis, psce 2006,” 2006. [19] W. Li, J. Tang, J. Ma, and Y. Liu, “Online detection of start time and location for hypocenter in north america power grid,” IEEE Transactions on Smart Grid, vol. 1, no. 3, pp. 253–260, 2010. [20] K. Mei, S. M. Rovnyak, and C.-M. Ong, “Clustering-based dynamic event location using wide-area phasor measurements,” IEEE Transactions on Power Systems, vol. 23, no. 2, pp. 673–679, 2008. [21] J. S. Thorp, C. E. Seyler, and A. G. Phadke, “Electromechanical wave propagation in large electric power systems,” IEEE Transactions on Circuits and Systems I: Fundamental Theory and Applications, vol. 45, no. 6, pp. 614–622, 1998. [22] T. Xia, H. Zhang, R. Gardner, J. Bank, J. Dong, J. Zuo, Y. Liu, L. Beard, P. Hirsch, G. Zhang et al., “Wide-area frequency based event location estimation,” in 2007 IEEE Power Engineering Society General Meeting. IEEE, 2007, pp. 1–7. [23] G. Zheng, Y. Liu, and G. Radman, “Wide area frequency based generation trip event location estimation,” in 2012 IEEE Power and Energy Society General Meeting. IEEE, 2012, pp. 1–6. [24] W.-T. Li, C.-K. Wen, J.-C. Chen, K.-K. Wong, J.-H. Teng, and C. Yuen, “Location identification of power line outages using pmu measurements with bad data,” IEEE Transactions on Power Systems, vol. 31, no. 5, pp. 3624–3635, 2015. [25] G. Frigo, A. Derviˇskadi´c, Y. Zuo, and M. Paolone, “Pmu-based rocof measurements: Uncertainty limits and metrological significance in power system applications,” IEEE Transactions on Instrumentation and Measurement, vol. 68, no. 10, pp. 3810–3822, 2019. [26] U. Rudez and R. Mihalic, “Analysis of underfrequency load shedding using a frequency gradient,” IEEE transactions on power delivery, vol. 26, no. 2, pp. 565–575, 2009. [27] H. Zhang, F. Shi, Y. Liu, and V. Terzija, “Adaptive online disturbance location considering anisotropy of frequency propagation speeds,” IEEE Transactions on Power Systems, vol. 31, no. 2, pp. 931–941, 2015. [28] D.-I. Kim, A. White, and Y.-J. Shin, “Pmu-based event localization technique for wide-area power system,” IEEE Transactions on Power Systems, vol. 33, no. 6, pp. 5875–5883, 2018. [29] S. M. Rovnyak and K. Mei, “Dynamic event detection and location using wide area phasor measurements,” European Transactions on Electrical Power, vol. 21, no. 4, pp. 1589–1599, 2011. [30] R. Azizipanah-Abarghooee, M. Malekpour, M. Paolone, and V. Terzija, “A new approach to the online estimation of the loss of generation size in power systems,” IEEE Transactions on Power Systems, vol. 34, no. 3, pp. 2103–2113, 2018. [31] N. Shams, P. Wall, and V. Terzija, “Active power imbalance detection, size and location estimation using limited pmu measurements,” IEEE Transactions on Power Systems, vol. 34, no. 2, pp. 1362–1372, 2018. [32] S. Azizi, M. R. Jegarluei, A. S. Dobakhshari, G. Liu, and V. Terzija, “Wide-area identification of the size and location of loss of generation events by sparse pmus,” IEEE Transactions on Power Delivery, vol. 36, no. 4, pp. 2397–2407, 2020. [33] G. G. Solutions, “Enhanced frequency control capability (EFCC), optimisation detailed design,” Jan 2016. [Online]. Available: https://www.nationalgrideso. com/document/135981/download [34] Y. Cheng, R. Azizipanah-Abarghooee, S. Azizi, L. Ding, and V. Terzija, “Smart frequency control in low inertia energy systems based on frequency response techniques: A review,” Applied Energy, vol. 279, p. 115798, 2020. [35] W. He, X. Yuan, and J. Hu, “Inertia provision and estimation of PLL-based dfig wind turbines,” IEEE Transactions on power systems, vol. 32, no. 1, pp. 510–521, 2016. [36] L. Harnefors, M. Schweizer, J. Kukkola, M. Routimo, M. Hinkkanen, and X. Wang, “Generic PLL-based grid-forming control,” IEEE Transactions on Power Electronics, vol. 37, no. 2, pp. 1201–1204, 2021. [37] X. Guo, D. Zhu, J. Hu, X. Zou, Y. Kang, and J. M. Guerrero, “Inertial PLL of grid-connected converter for fast frequency support,” CSEE Journal of Power and Energy Systems, 2022. [38] C. Zhang, E. Rakhshani, N. Veerakumar, J. L. R. Torres, and P. Palensky, “Modeling and optimal tuning of hybrid ESS supporting fast active power regulation of ully decoupled wind power generators,” IEEE Access, vol. 9, pp. 46 409–46 421, 2021. [39] J. Lee, S. Jeong, H. Kim, Y. Yoo, S. Jung, M. Yoon, and G. Jang, “Analytical approach for fast frequency response control of VSC HVDC,” IEEE Access, vol. 9, pp. 91 303–91 313, 2021. [40] M. Kabsha and Z. H. Rather, “A new control scheme for fast frequency support from HVDC connected offshore wind farm in low-inertia system,” IEEE Transactions on Sustainable Energy, vol. 11, no. 3, pp. 1829–1837, 2019. [41] K. Jose, O. Adeuyi, J. Liang, and C. E. Ugalde-Loo, “Coordination of fast frequency support from multi-terminal HVDC grids,” in 2018 IEEE international energy conference (ENERGYCON). IEEE, 2018, pp. 1–6. [42] O. Stanojev, U. Markovic, E. Vrettos, P. Aristidou, D. Callaway, and G. Hug, “Enhanced MPC for fast frequency control in inverter-dominated power systems,” in 2020 International Conference on Smart Energy Systems and Technologies (SEST). IEEE, 2020, pp. 1–6. [43] D. Yang, L. Hua, and X. Zhang, “Fast frequency support of a DFIG based on overspeed de-loaded curve,” in 2021 IEEE/IAS Industrial and Commercial Power System Asia (I&CPS Asia). IEEE, 2021, pp. 1314–1318. [44] M. Kheshti, S. Lin, X. Zhao, L. Ding, M. Yin, and V. Terzija, “Gaussian distribution-based inertial control of wind turbine generators for fast frequency response in low inertia systems,” IEEE Transactions on Sustainable Energy, vol. 13, no. 3, pp. 1641–1653, 2022. [45] X. Zhao, Y. Xue, and X.-P. Zhang, “Fast frequency support from wind turbine systems by arresting frequency nadir close to settling frequency,” IEEE Open Access Journal of Power and Energy, vol. 7, pp. 191–202, 2020. [46] G. Xu, L. Xu, and J. Morrow, “System frequency support using wind turbine kinetic energy and energy storage system,” in 2nd IET Renewable Power Generation Conference (RPG 2013). IET, 2013. [47] K. Sun, K.-J. Li, W. Bao, Z. Liu, M. Wang, W.-J. Lee et al., “Frequency compensation control strategy of energy storage in the wind-energy storage hybrid system for improving frequency response performance,” in 2019 IEEE Industry Applications Society Annual Meeting. IEEE, 2019, pp. 1–8. [48] W. Liu, G. Geng, Q. Jiang, H. Fan, and J. Yu, “Model-free fast frequency control support with energy storage system,” IEEE Transactions on Power Systems, vol. 35, no. 4, pp. 3078–3086, 2019. [49] Y. Yoo, S. Jung, and G. Jang, “Dynamic inertia response support by energy storage system with renewable energy integration substation,” Journal of Modern Power Systems and Clean Energy, vol. 8, no. 2, pp. 260–266, 2019. [50] W. Bao, L. Ding, Z. Liu, G. Zhu, M. Kheshti, Q.Wu, and V. Terzija, “Analytically derived fixed termination time for stepwise inertial control of wind turbines-part i: Analytical derivation,” International Journal of Electrical Power & Energy Systems, vol. 121, p. 106120, 2020. [51] Y. Guo, W. Bao, L. Ding, Z. Liu, M. Kheshti, Q. Wu, and V. Terzija, “Analytically derived fixed termination time for stepwise inertial control of wind turbines part ii: Application strategy,” International Journal of Electrical Power & Energy Systems, vol. 121, p. 106106, 2020. [52] P. Anderson and M. Mirheydar, “A low-order system frequency response model,” IEEE Transactions on Power Systems, vol. 5, no. 3, pp. 720–729, 1990. [53] N. G. ESO, “Dynamic containment response balancing service, test guidance for providers,” Jun 2022. [54] ——, The grid code, Issue 6, Revision 16. Great Britain, 2023. [55] J. J. Grainger and W. D. Stevenson Jr, Power system analysis. McGraw-Hill series in electrical and computer engineering, 1994. [56] W. C. New and W. C. New, Load shedding, load restoration and generator protection using solid-state and electromechanical underfrequency relays. General Electric Company, Power Systems Management, 1974. [57] J. D. Glover, M. S. Sarma, and T. Overbye, Power system analysis & design, SI version. Cengage Learning, 2012. [58] A. Ulbig, T. S. Borsche, and G. Andersson, “Impact of low rotational inertia on power system stability and operation,” IFAC Proceedings Volumes, vol. 47, no. 3, pp. 7290–7297, 2014. [59] U. Rudez and R. Mihalic, “Wams-based underfrequency load shedding with shortterm frequency prediction,” IEEE Transactions on Power Delivery, vol. 31, no. 4, pp. 1912–1920, 2015. [60] S. Azizi, M. Sun, G. Liu, and V. Terzija, “Local frequency-based estimation of the rate of change of frequency of the center of inertia,” IEEE Transactions on Power Systems, vol. 35, no. 6, pp. 4948–4951, 2020. [61] J. S. Cortes and D. R. Romero, “Esquemas dinamicos de tiro de carga por baja frecuencia mediante logica difusa,” in 27 Reunion Internacional de Verano de Potencia, Aplicaciones Industriales y Exposicion Industrial (RVP-AI). IEEE, 2014, pp. 1–8 SIS–17, PON–89. [62] P. Warren, “A review of demand-side management policy in the UK,” Renewable and Sustainable Energy Reviews, vol. 29, pp. 941–951, 2014. [63] H. Bevrani, Robust power system frequency control. Springer, 2014, vol. 4. [64] A. J. Wood, B. F. Wollenberg, and G. B. Shebl´e, Power generation, operation, and control. John Wiley & Sons, 2013. [65] C. Rowland, D. Smaha, and J. Pope, “Coordination of load conservation with turbine-generator underfrequency protection,” IEEE Transactions on Power Apparatus and Systems, no. 3, pp. 1137–1150, 1980. [66] Y. Omar, I. Abidin, S. Yusof, H. Hashim, and H. A. Rashid, “Under frequency load shedding (ufls): Principles and implementation,” in 2010 IEEE International Conference on Power and Energy. IEEE, 2010, pp. 414–419. [67] J. Sanchez Cortes, “Diseño de esquemas de tiro de carga por baja frecuencia utilizando tecnicas inteligentes,” MSc thesis, 2014. [68] M. Abedini, M. Sanaye-Pasand, and S. Azizi, “Adaptive load shedding scheme to preserve the power system stability following large disturbances,” IET Generation, Transmission & Distribution, vol. 8, no. 12, pp. 2124–2133, 2014. [69] RielloUPS, “The blackout report: what happens when there is no power?” 2019. [70] T. S. Borsche, T. Liu, and D. J. Hill, “Effects of rotational inertia on power system damping and frequency transients,” in 2015 54th IEEE conference on decision and control (CDC). IEEE, 2015, pp. 5940–5946. [71] I. P. P. S. R. Committee et al., “Ieee guide for abnormal frequency protection for power generating plants,” IEEE Std C37. 106-2003 (Revision of ANSI/IEEE C37. 106-1987), pp. 0 1–34, 2004. [72] J. Berdy, P. Brown, and L. Goff, “Protection of steam turbine generators during abnormal frequency conditions,” General Electric Company, Schenectady, New York, 1974. [73] R. Warner, T. Dillman, and M. Baldwin, “Off-frequency turbine-generator unit operation,” in Proc. Am. Power Conf.;(United States), vol. 38, 1976. [74] P. K. Pathak and A. R. Gupta, “Battery energy storage system,” in 2018 4th International Conference on Computational Intelligence & Communication Technology (CICT). IEEE, 2018, pp. 1–9. [75] M. Kheshti, L. Ding, W. Bao, M. Yin, Q. Wu, and V. Terzija, “Toward intelligent inertial frequency participation of wind farms for the grid frequency control,” IEEE Transactions on Industrial Informatics, vol. 16, no. 11, pp. 6772–6786, 2019. [76] L. Ruttledge, N. W. Miller, J. O’Sullivan, and D. Flynn, “Frequency response of power systems with variable speed wind turbines,” IEEE transactions on Sustainable Energy, vol. 3, no. 4, pp. 683–691, 2012. [77] M. Garmroodi, G. Verbiˇc, and D. J. Hill, “Frequency support from wind turbine generators with a time-variable droop characteristic,” IEEE Transactions on Sustainable Energy, vol. 9, no. 2, pp. 676–684, 2017. [78] F. D´ıaz-Gonz´alez, M. Hau, A. Sumper, and O. Gomis-Bellmunt, “Participation of wind power plants in system frequency control: Review of grid code requirements and control methods,” Renewable and Sustainable Energy Reviews, vol. 34, pp. 551–564, 2014. [79] J. Van de Vyver, J. D. De Kooning, B. Meersman, L. Vandevelde, and T. L. Vandoorn, “Droop control as an alternative inertial response strategy for the synthetic inertia on wind turbines,” IEEE Transactions on Power Systems, vol. 31, no. 2, pp. 1129–1138, 2015. [80] X. Zhang, X. Zha, S. Yue, and Y. Chen, “A frequency regulation strategy for wind power based on limited over-speed de-loading curve partitioning,” IEEE Access, vol. 6, pp. 22 938–22 951, 2018. [81] W. Bao, Q. Wu, L. Ding, S. Huang, F. Teng, and V. Terzija, “Synthetic inertial control of wind farm with bess based on model predictive control,” IET Renewable Power Generation, vol. 14, no. 13, pp. 2447–2455, 2020. [82] M. Dreidy, H. Mokhlis, and S. Mekhilef, “Inertia response and frequency control techniques for renewable energy sources: A review,” Renewable and sustainable energy reviews, vol. 69, pp. 144–155, 2017. [83] C. Rahmann, J. Jara, and M. Salles, “Effects of inertia emulation in modern wind parks on isolated power systems,” in 2015 IEEE Power & Energy Society General Meeting. IEEE, 2015, pp. 1–5. [84] W. Bao, L. Ding, S. Yin, K. Wang, and V. Terzija, “Active rotor speed protection for dfig synthetic inertia control,” 2016. [85] R. Eriksson, N. Modig, and K. Elkington, “Synthetic inertia versus fast frequency response: a definition,” IET renewable power generation, vol. 12, no. 5, pp. 507– 514, 2018. [86] U. Energy, “Pathways for the gb electricity sector to 2030,” Full Report, 2016. [87] N. Mendis, K. M. Muttaqi, and S. Perera, “Management of batterysupercapacitor hybrid energy storage and synchronous condenser for isolated operation of pmsg based variable-speed wind turbine generating systems,” IEEE Transactions on smart grid, vol. 5, no. 2, pp. 944–953, 2014. [88] S. Azizi and M. Sanaye-Pasand, “From available synchrophasor data to shortcircuit fault identity: Formulation and feasibility analysis,” IEEE Transactions on Power Systems, vol. 32, no. 3, pp. 2062–2071, 2016. [89] K. Jia, Z. Yang, Y. Fang, T. Bi, and M. Sumner, “Influence of inverter-interfaced renewable energy generators on directional relay and an improved scheme,” IEEE Transactions on Power Electronics, vol. 34, no. 12, pp. 11 843–11 855, 2019. [90] J. S. Cortes, M. R. Jegarluei, P. Aristidou, K. Li, and S. Azizi, “Size/location estimation for loss of generation events in power systems with high penetration of renewables,” Electric Power Systems Research, vol. 219, p. 109242, 2023. [91] A. S. Dobakhshari, S. Azizi, M. Paolone, and V. Terzija, “Ultra fast linear state estimation utilizing scada measurements,” IEEE Transactions on Power Systems, vol. 34, no. 4, pp. 2622–2631, 2019. [92] C. D. Meyer, Matrix analysis and applied linear algebra. SIAM, 2000. [93] T. T. GmbH, Grid code-High and extra high voltage, 2017. [94] R. D. Zimmerman, C. E. Murillo-S´anchez, and D. Gan, MATPOWER: A MATLAB power system simulation package. Manual, Power Systems Engineering Research Center, Ithaca NY, 2007, vol. 3.2. [95] S. Azizi, A. S. Dobakhshari, S. A. N. Sarmadi, and A. M. Ranjbar, “Optimal PMU placement by an equivalent linear formulation for exhaustive search,” IEEE Transactions on Smart Grid, vol. 3, no. 1, pp. 174–182, 2012. [96] S. M. for Power SystemsWorking Group et al., “IEEE standard for synchrophasor measurements for power systems,” IEEE Std C, vol. 37, pp. 1–61. [97] A. Abur and A. G. Exposito, Power system state estimation: theory and implementation. CRC press, 2004. [98] S. Sarri, M. Pignati, P. Romano, L. Zanni, and M. Paolone, “A hardware-in-theloop test platform for the performance assessment of a PMU-based real-time state estimator for active distribution networks,” in 2015 IEEE Eindhoven PowerTech. IEEE, 2015, pp. 1–6. [99] A. G. Phadke and J. S. Thorp, Computer relaying for power systems. John Wiley & Sons, 2009. [100] F. C. Schweppe and J. Wildes, “Power system static-state estimation, part I: Exact model,” IEEE Transactions on Power Apparatus and Systems, vol. PAS- 89, no. 1, pp. 120–125, 1970. [101] J. Sanchez Cortes, M. Rezaei Jegarluei, and S. Azizi, “Targeted fast frequency response by decomposing frequency into transient and steady-state deviations,” in 2023 International Conference on Energy Technologies for Future Grids (ETFG). IEEE, 2023. [102] R. Bracewell, The Fourier transform and its applications. McGraw-Hill, 1986. [103] A. Aksoy and M. Martelli, “Mixed partial derivatives and Fubini’s theorem,” The College Mathematics Journal, vol. 33, no. 2, pp. 126–130, 2002. [104] N. Chaudhuri, B. Chaudhuri, R. Majumder, and A. Yazdani, Multi-terminal direct-current grids: Modeling, analysis, and control. John Wiley & Sons, 2014. [105] P. Rodr´ıguez, J. Pou, J. Bergas, J. I. Candela, R. P. Burgos, and D. Boroyevich, “Decoupled double synchronous reference frame PLL for power converters control,” IEEE Transactions on Power Electronics, vol. 22, no. 2, pp. 584–592, 2007. [106] M. R. Jegarluei, P. Aristidou, and S. Azizi, “Wide-area backup protection against asymmetrical faults in the presence of renewable energy sources,” International Journal of Electrical Power & Energy Systems, vol. 144, p. 108528, 2023. [107] K. Ma, W. Chen, M. Liserre, and F. Blaabjerg, “Power controllability of a threephase converter with an unbalanced ac source,” IEEE Transactions on Power Electronics, vol. 30, no. 3, pp. 1591–1604, 2014."],"dcterms:accessrights":["public"],"dc:title":["Fast frequency containment in power systems with volatile inertia"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000347060599"]},"updated_at":"2026-11-18T23:25:06Z"}