{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:34106"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:34106","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Development of Novel Coatings for Full Field Strain Measurements","abstract":"Reflection Photoelastic Stress Analysis (RPSA) is an experimental technique used in industries to assist in a variety of design and manufacture processes. Users can benefit from immediate qualitative and quantitative information, for example, about maximum shear strains in complex geometries. One such user of RPSA, and the focus of this research, is Airbus that perform RPSA within the manufacturing process of their aircraft wing assemblies. Although insightful, RPSA procedures suffer from complicated application processes, a need for skilled engineers and large timescales for data collection. These issues all stem from one vital component — the photoelastic coating material. Common commercially available RPSA coatings are designed in such a way to compensate for failings in RPSA apparatus that were once insensitive to small changes in component surface strain. However, current commercially available automated photoelastic collection and analysis apparatus have given the potential for RPSA to be a truly effective method. This is due to high detection sensitivity of better than 0.1 nm that translates to a 20 micro strain resolution. RPSA techniques could benefit and compensate for using easy to apply, thinner (approximately 50 microns) but less sensitive coatings. As a result, this research aims to investigate and develop a novel, time-efficient and `smart' coating material that updates current RPSA methods. Whilst applications at Airbus are the focus of this research the wider applicability of this coating is extensive. Within this thesis, the key criteria for the new coating are outlined and explained by reviewing relevant theory, literature and all conducted experimental research. Coating development is divided into two main investigative topics: reflection photoelasticity (RPE) and mechanoluminescence (ML). The RPE development topic utilised a range of UV curable resins that were rationally designed into an optimum formulation. The coating was designed and tested with the automated RPE imaging device — the Grey Field Polariscope (GFP). The choice of UV curable materials provides a new range of rapid application coatings boasting a 20 s cure time whilst possessing similar RPE sensitivities of existing commercial products. Additionally, the coating was designed with thickness correction capabilities within post-processing to further promote the ease of use of the coating. By introducing a red tint to the formulation and imaging with the GFP, it was shown that thickness differences could be corrected in order to provide accurate RPSA data. At targetted thicknesses of 50 microns, correction by manipulation of different wavelengths of light has not been attempted before. Performing calibration experiments, the clear (WF31) and red tinted (WF-Red1) UV curable materials possessed strain-optic coefficients indicative of medium-high sensitivity coatings (K = 0.8 - 0.1). The ML topic investigated the introduction of a mechanoluminescent phosphor to the developed UV curable formulation to produce a novel dual-technique strain imaging coating. ML materials generate light under the influence of strain with the intensity able to provide a map of the surface's strain field. The objective was to capture the production of ML light whilst performing RPE simultaneously in order to provide additional information that would support both techniques. The commonly researched ML material strontium aluminate was utilised and was added at a 30 % weight percentage to the optimised UV curable formulation. It was demonstrated for the first time that concurrent measurement of both techniques was possible by filtering the green ML light against RPE performed monochromatically using red light. Qualitative comparisons demonstrated it utility, however challenges utilising ML within elastic conditions limits it use. Firstly, it was observed that the ML coating had a `one-shot' application with the intensity of produced light diminishing with subsequent loads. This was a result of the ML phosphor debonding with the carrier resin. Additionally, the light production within elastic conditions was poor requiring high strain rates to produce observable conditions. As a result, eliminating all ambient light is a prerequisite for successful application. However, ML demonstrated relativity high light intensities when at areas of high strain, singularities, and when the component breached its elastic limit. Therefore, it has been shown that ML's potentially usefulness could be a validation technique to go alongside photoelasticity. The research has successfully demonstrated the high performance of a new reflection coating with the ability for application, data collection and processing, and coating removal to be performed in one single day — an order of magnitude better than existing techniques. Combination with ML materials for simultaneous RPE and ML capture has been demonstrated with the ability for RPE validation however not without difficulties. However, a novel technique/apparatus has been designed and implemented which allows for the first time PE and ML data to be measured simultaneously.","abstract_html":"Reflection Photoelastic Stress Analysis (RPSA) is an experimental technique used in industries to assist in a variety of design and manufacture processes. Users can benefit from immediate qualitative and quantitative information, for example, about maximum shear strains in complex geometries. One such user of RPSA, and the focus of this research, is Airbus that perform RPSA within the manufacturing process of their aircraft wing assemblies. Although insightful, RPSA procedures suffer from complicated application processes, a need for skilled engineers and large timescales for data collection. These issues all stem from one vital component — the photoelastic coating material. Common commercially available RPSA coatings are designed in such a way to compensate for failings in RPSA apparatus that were once insensitive to small changes in component surface strain. However, current commercially available automated photoelastic collection and analysis apparatus have given the potential for RPSA to be a truly effective method. This is due to high detection sensitivity of better than 0.1 nm that translates to a 20 micro strain resolution. RPSA techniques could benefit and compensate for using easy to apply, thinner (approximately 50 microns) but less sensitive coatings. As a result, this research aims to investigate and develop a novel, time-efficient and `smart&#x27; coating material that updates current RPSA methods. Whilst applications at Airbus are the focus of this research the wider applicability of this coating is extensive. Within this thesis, the key criteria for the new coating are outlined and explained by reviewing relevant theory, literature and all conducted experimental research. Coating development is divided into two main investigative topics: reflection photoelasticity (RPE) and mechanoluminescence (ML). The RPE development topic utilised a range of UV curable resins that were rationally designed into an optimum formulation. The coating was designed and tested with the automated RPE imaging device — the Grey Field Polariscope (GFP). The choice of UV curable materials provides a new range of rapid application coatings boasting a 20 s cure time whilst possessing similar RPE sensitivities of existing commercial products. Additionally, the coating was designed with thickness correction capabilities within post-processing to further promote the ease of use of the coating. By introducing a red tint to the formulation and imaging with the GFP, it was shown that thickness differences could be corrected in order to provide accurate RPSA data. At targetted thicknesses of 50 microns, correction by manipulation of different wavelengths of light has not been attempted before. Performing calibration experiments, the clear (WF31) and red tinted (WF-Red1) UV curable materials possessed strain-optic coefficients indicative of medium-high sensitivity coatings (K = 0.8 - 0.1). The ML topic investigated the introduction of a mechanoluminescent phosphor to the developed UV curable formulation to produce a novel dual-technique strain imaging coating. ML materials generate light under the influence of strain with the intensity able to provide a map of the surface&#x27;s strain field. The objective was to capture the production of ML light whilst performing RPE simultaneously in order to provide additional information that would support both techniques. The commonly researched ML material strontium aluminate was utilised and was added at a 30 % weight percentage to the optimised UV curable formulation. It was demonstrated for the first time that concurrent measurement of both techniques was possible by filtering the green ML light against RPE performed monochromatically using red light. Qualitative comparisons demonstrated it utility, however challenges utilising ML within elastic conditions limits it use. Firstly, it was observed that the ML coating had a `one-shot&#x27; application with the intensity of produced light diminishing with subsequent loads. This was a result of the ML phosphor debonding with the carrier resin. Additionally, the light production within elastic conditions was poor requiring high strain rates to produce observable conditions. As a result, eliminating all ambient light is a prerequisite for successful application. However, ML demonstrated relativity high light intensities when at areas of high strain, singularities, and when the component breached its elastic limit. Therefore, it has been shown that ML&#x27;s potentially usefulness could be a validation technique to go alongside photoelasticity. The research has successfully demonstrated the high performance of a new reflection coating with the ability for application, data collection and processing, and coating removal to be performed in one single day — an order of magnitude better than existing techniques. Combination with ML materials for simultaneous RPE and ML capture has been demonstrated with the ability for RPE validation however not without difficulties. However, a novel technique/apparatus has been designed and implemented which allows for the first time PE and ML data to be measured simultaneously.","abstract_has_math":false,"creators":["Fraser, William"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Tomlinson, Rachel","Parnell, Andrew"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-07","date_published":"2023-07","updated_at":"2026-11-18T23:25:06Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/R513313/1"],"render_values":[{"text":"EP/R513313/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000154305617"],"render_values":[{"text":"0000-0001-5430-5617","href":"https://orcid.org/0000-0001-5430-5617","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/34106/1/Fraser.%20William%2C%20190207623.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A34106","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tomlinson, Rachel","Parnell, Andrew"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC Doctoral Training Partnership (DTP) Scholarship"]},{"key":"dc:creator","label":"Author","values":["Fraser, William"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000154305617"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-07"]},{"key":"dc:date.issued","label":"Date","values":["2023-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Mechanical Engineering (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/34106/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] E. Hearn. Mechanics of Materials 2: An introduction to the Mechanics of Elastic and Plastic Deformation of Solids and Structural Materials, volume 3. Butterworth-Heinemann, 1997. [2] K. Ramesh. Photoelasticity, pages 701–742. Springer US, Boston, MA, 2008. [3] K. Ramesh. Digital Photoelasticity: Advanced Techniques and Applications. Springer Berlin Heidelberg, 2000. [4] G. Calvert, J. Lesniak, and M. Honlet. Applications of modern automated photoelasticity to industrial problems. Insight, 44(4):224–227, 2002. [5] B. Neethi Simon and K. Ramesh. A Simple Method to Plot Photoelastic Fringes and Phasemaps from Finite Element Results. Journal of Aerospace Sciences and Technologies, 62(3), 2010. [6] M. Geramizadeh, H. Katoozian, R. Amid, and M. Kadkhodazadeh. Comparison of finite element results with photoelastic stress analysis around dental implants with different threads. Dental and medical problems, 55(1):17–22, 2018. [7] Vishay Precision Group: Micro Measurements. PhotoStress Coating Materials and Adhesives. Retrieved from http://www.vishaypg.com/docs/11222/pscoat.pdf, 2015. [8] B. E. Foust, J. R. Lesniak, and R. E. Rowlands. Stress analysis of a pinned wood joint by grey-field photoelasticity. Composites Part B: Engineering, 61:291–299, 2014. [9] J. Hubner, J. Nicolosi, L. Chen, P. Ifju, and W. El-Ratal. Oblique incidence response of photoelastic coatings. Experimental Techniques, 29(3):52–56, 2005. [10] J. P. Hubner, P. G. Ifju, K. S. Schanze, Y. Liu, L. Chen, and W. El-Ratal. Luminescent photoelastic coatings. Experimental Mechanics, 44(4):416–424, 2004. [11] Vishay Precision Group: Micro Measurements. Instructions for Casting and Contouring PhotoStress Sheets: Application note B-221. Retrieved from http://www.vishaypg.com/ docs/11221/ib-221.pdf, 2015. [12] Vishay Precision Group: Micro Measurements. Instructions for Bonding Flat and Contoured PhotoStress Sheets: Application Note B-223. Retrieved from http://www.vishaypg.com/ docs/11223/ib-223ib.pdf, 2015. [13] Airbus. A320ceo. https://aircraft.airbus.com/en/aircraft/a320-the-mostsuccessful- aircraft-family-ever/a320ceo Date Accessed 03/04/2023. [14] J. Lesniak and M. Zickel. Applications of automated grey-field polariscope. In Proceedings of the 1998 SEM Spring Conference on Experimental Mechanics, pages 298–301, Houston, Texas, 1998. [15] H. D. Young, R. A. Freedman, F. W. Sears, and M. W. Zemansky. Sears and Zemansky’s university physics : with modern physics technology update. Pearson Education, Harlow, Essex, thirteenth edition, 2014. [16] E. Hecht. Optics. Pearson, 5th edition, 2017. [17] M. Bass, E. W. V. Stryland, D. R. Williams, and W. L. Wolfe. Handbook of Optics Volume II Devices, Measurements, and Properties. McGraw-Hill Professional, 2nd edition, 1995. [18] J. Pavlin, N. Vaupotič, and M. Čepič. Direction dependence of the extraordinary refraction index in uniaxial nematic liquid crystals. Eur. J. Phys., 34(2):331–344, jan 2013. [19] E. Wolf and M. Born. Principle of Optics. Pergamon Press, 5th edition, 1975. [20] A. Praveen, Z. Weijun, and R. Raghunath. Photoelastic birefringence of copolymers with non-planar structure. Polymer (Guildf)., 164:217–222, 2019. [21] D. Harrington and S. Sueoka. Polarization modeling and predictions for DKIST part 3: focal ratio and thermal dependencies of spectral polarization fringes and optic retardance. J. Astron. Telesc. Instruments, Syst., 4(1), 2018. [22] F. El-Diasty, M. A. Soliman, A. F. T. Elgendy, and A. Ashour. Birefringence dispersion in uniaxial material irradiated by gamma rays: cellulose triacetate films. J. Opt. A Pure Appl. Opt., 9(3):247–252, feb 2007. [23] G. Cloud. Optical methods in experimental mechanics - Part 29: Photoelasticity I - Birefringence and relative retardation. Exp. Tech., 31(6):27–29, 2007. [24] P. Theocaris and E. Gdoutos. Two-Dimensional Photoelasticity, page 113. Springer Berlin Heidelberg, Berlin, Heidelberg, 1979. [25] G. H. Ryder. Strength of materials. The Macmillan Press Ltd, 3rd edition, 1969. [26] T. H. G. Megson. Structural and stress analysis. Elsevier Butterworth-Heinemann, 2nd edition, 2005. [27] G. Cloud. Optical Methods in Experimental Mechanics - Part 30: Photoelasticity II - Birefringence in Materials. Exp. Tech., 32(1):13–16, 2008. [28] Tadashi Inoue. Strain-Induced Birefringence of Amorphous Polymers and Molecular Design of Optical Polymers. ACS Applied Polymer Materials, 3(5):2264–2273, 2021. [29] T. Freegarde. Introduction to the Physics of Waves. Cambridge University Press, 2012. [30] P. Hariharan. Basics of interferometry. Elsevier Academic Press, 2nd edition, 2006. [31] K. Ramesh. Photoelasticity. In Springer Handbook Experimental Solid Mechanics, pages 701 – 742. Springer, 2008. [32] M. Ramji and K. Ramesh. Whole field evaluation of stress components in digital photoelasticity - Issues, implementation and application. Opt. Lasers Eng., 46(3):257–271, 2008. [33] E. A. Patterson. Digital Photoelasticity: Principles, Practice and Potential. Strain, 38(1):27–39, 2002. [34] K. Ramesh and S. Sasikumar. Digital photoelasticity: Recent developments and diverse applications. Optics and Lasers in Engineering, 135, 2020. [35] F. W. Hecker and B. Morche. Computer-Aided Measurement of Relative Retardations in Plane Photoelasticity. In H Wieringa, editor, Exp. Stress Anal., pages 535–542, Dordrecht, 1986. Springer Netherlands. [36] E. A. Patterson and Z. F. Wang. Towards full field automated photoelastic analysis of complex components. Strain, 27(2):49–53, 1991. [37] A. Asundi, L. Tong, and C. Boay. Phase-shifting method with a normal polariscope. Appl. Opt., 38(28):5931–5935, oct 1999. [38] Z. F. Wang and E. A. Patterson. Use of phase-stepping with demodulation and fuzzy sets for birefringence measurement. Opt. Lasers Eng., 22(2):91–104, 1995. [39] W. Ji and E. Patterson. Simulation of errors in automated photoelasticity. Exp. Mech., 38(2):132–139, 1998. [40] M. Ramji and K. Ramesh. Stress separation in digital photoelasticity part a-photoelastic data unwrapping and smoothing. Journal of Aerospace Sciences and Technologies, pages 5–15, 2008. [41] G. M. Brown and J. L. Sullivan. The computer-aided holophotoelastic method. Experimental Mechanics, 30(2):135–144, 1990. [42] A. Ajovalasit, S. Barone, and G. Petrucci. A method for reducing the influence of quarter-wave plate errors in phase stepping photoelasticity. J. Strain Anal. Eng. Des., 33(3):207–216, 1998. [43] G. Cloud. Optical Methods in Experimental Mechanics Part 38: Photoelasticity X—Transfer of Stress Data From Model to Prototype. Exp. Tech., 33(5), 2008. [44] K. Ramesh. Basics of photoelasticity and photoplasticity. In Developments in Photoelasticity, 2053-2563, pages 1–41. IOP Publishing, 2021. [45] Vishay Precision Group: Micro Measurements. Corrections to Photoelastic Coating Fringe-Order Measurements: Technical Note TN-706-1. Retrieved from https://docs. micro-measurements.com/?id=2536, 2015. [46] E. A. Patterson and Z. F. Wang. Simultaneous observation of phase-stepped images for automated photoelasticity. J. Strain Anal. Eng. Des., 33(1):1–15, 1998. [47] J. Lesniak, S. J. Zhang, and E. A. Patterson. Design and evaluation of the poleidoscope: A novel digital polariscope. Exp. Mech., 44(2):128–135, 2004. [48] J. W. Hobbs, R. J. Greene, and E. A. Patterson. A novel instrument for transient photoelasticity. Experimental Mechanics, 43(4):403–409, 2003. [49] J. Lesniak, M. Zickel, and C. W. D. Johnson. An Innovative Polariscope for Photoelastic Stress Analysis. In Proc. 1997 SEM Spring Conf. Exp. Mech., pages 219 – 224, 1997. [50] Stress Photonics Inc. GFP1400 Operator’s Manual, 2014. [51] M. Mesnager. Sur la Determination Optique des Tensions Interieures dans les Solides a Trois Dimensions (French) [On the Optical Determination of Interior Tensions in Three Dimensional Solids]. Comptes Rendus, (190):1249, 1930. [52] Engineering ToolBox. Young’s Modulus - Tensile and Yield Strength for common Materials. https://www.engineeringtoolbox.com/young-modulus-d_417.html Date Accessed 30/12/2019, 2003. [53] F. Zandman, S. Redner, and J. W. Dally. Photoelastic coatings. Society for Experimental Stress Analysis. SESA monograph ; no. 3. Iowa State University Press, Ames, 1977. [54] S. Paipetis. Photoelasticity in engineering practice - Conventional Three-Dimensional Photoelasticity: A Review of Principles and Materials. Elsevier Applied Science, London, 1985. [55] G. Cloud. Optical Methods in Experimental Mechanics - Part 42: Photoelasticity XIV - Reflection Photoelasticity. Experimental Techniques, 34(4):15 – 19, 2010. [56] ITW Performance Polymers. Devcon 2 Ton®Epoxy Technical Data Sheet. Retrieved from https://itwperformancepolymers.com/wp-content/uploads/umb/1008/2-tonepoxy_ 041318.pdf, 2018. [57] D. Lam and M. W. Ellens. Method for detecting stress and strain. Retrieved from https: //patents.google.com/patent/US6650405B2/en, 2001. [58] F. Zandman. Stress Analysis of a Guided Missile Tail Section with the Photoelastic Technique. In SESA, volume 17, pages 135 – 150, 1960. [59] B. Kenny and J. W. Hugill. Comparison of Fringe Multiplication and Tardy Compensation Methods for a Frozen Stress Investigation. Strain, 3(1):3–7, 1967. [60] G. H. Staab and T. G. Richard. An experimental investigation of cog-root strains in V-belts using birefringent coatings. Exp. Mech., 22(12):476–480, dec 1982. [61] B. E. Foust, J. R. Lesniak, and R. E. Rowlands. Determining Individual Stresses Throughout a Pinned Aluminum Joint by Reflective Photoelasticity. Experimental Mechanics, 51(9):1441–1452, 2011. [62] J. Hubner, L. Chen, Y. Liu, K. Schanze, P. Ifju, J. Nicolosi, and W. El-Ratal. Characterization of a new luminescent photoelastic coating. Experimental Mechanics, 45(2):137–143, 2005. [63] J. Hubner, S. Jiang, Y. Liu, K. Schanze, P. Ifju, D. A. Jenkins, and W. El-Ratal. Method and apparatus for measuring strain using a luminescent photoelastic coating . Retrieved from https://patents.google.com/patent/US20040066503A1/en, 2004. [64] F. Bacon. Of the advancement of learning. J. M. Dent & sons, 1915. [65] B. P. Chandra. Mechanoluminescence. In D. R. Vij, editor, Luminescence of Solids, pages 361–389. Springer US, Boston, MA, 1998. [66] N. C. Eddingsaas and K. S. Suslick. Light from sonication of crystal slurries. Nature, 444(7116):163, 2006. [67] A. Feng, S. Michels, A. Lamberti, and P. F. Smet. Mechanoluminescent Materials: A New Way to Analyze Stress by Light. Proceedings, 2(8):492, 2018. [68] D. O. Olawale, T. Dickens, W. G. Sullivan, O. I. Okoli, J. O. Sobanjo, and B. Wang. Progress in triboluminescence-based smart optical sensor system. J. Lumin., 131(7):1407 – 1418, 2011. [69] B. P. Chandra, R. N. Baghel, and V. K. Chandra. Mechanoluminescence glow curve of ZnS:Mn. Chalcogenide Lett., 7(1):1–9, 2010. [70] B P Chandra, V K Chandra, and Piyush Jha. Microscopic theory of elastico-mechanoluminescent smart materials. Appl. Phys. Lett., 104(3), 2014. [71] C. Li, C. Xu, L. Zhang, H. Yamada, and Y. Imai. Dynamic visualization of stress distribution on metal by mechanoluminescence images. J. Vis., 11(4):329–335, 2008. [72] V K Chandra and B P Chandra. Dynamics of the mechanoluminescence induced by elastic deformation of persistent luminescent crystals. Journal of Luminescence, 132(3):858–869, 2012. [73] H. Zhang, H. Yamada, N. Terasaki, and C. Xu. Ultraviolet mechanoluminescence from SrAl2O4:Ce and SrAl2O4:Ce,Ho. Applied Physics Letters, 91(8), aug 2007. [74] W. Wang, T. Matsubara, Y. Takao, Y. Imai, and C. Xu. Visualization of Stress Distribution Using Smart Mechanoluminescence Sensor. Mater. Sci. Forum, 614:169–174, 2009. [75] S. Timilsina, K. H. Lee, I. Y. Jang, and J. S. Kim. Mechanoluminescent determination of the mode I stress intensity factor in SrAl2O4:Eu2+,Dy3+. Acta Materialia, 61(19):7197–7206, 2013. [76] G. J. Yun, M. R. Rahimi, A. H. Gandomi, G. Lim, and J. Choi. Stress sensing performance using mechanoluminescence of SrAl 2 O 4 :Eu (SAOE) and SrAl 2 O 4 :Eu, Dy (SAOED) under mechanical loadings. Smart Materials and Structures, 22(5):055006, 2013. [77] V. K. Chandra and B. P. Chandra. Suitable materials for elastico mechanoluminescence-based stress sensors. Optical Materials, 34(1):194–200, 2011. [78] A.F. Banishev and A.A. Banishev. Deformation Stimulated Luminescence of a Composite Produced on the Basis of Polymethylmethacrylate Transparent in the Visible Region and Finely Dispersed Powder of SrAl2O4:(Eu2+, Dy3+) Phosphor. Inorg. Mater. Appl. Res., 10:647 – 651, 2019. [79] A. I. Azad, M. R. Rahimi, and G. J. Yun. Quantitative full-field strain measurements by SAOED (SrAl2O4:Eu2+,Dy3+) mechanoluminescent materials. Smart Materials and Structures, 25(9):95032, 2016. [80] K. Kanamaru and H. Utsunomiya. In-situ observation of nonuniform deformation during tensile test of aluminum alloy sheet by means of screen-printed mechanoluminescence film. Scripta Materialia, 209:114388, 2022. [81] C. N. Xu, T. Watanabe, M. Akiyama, and X. G. Zheng. Preparation and characteristics of highly triboluminescent ZnS film. Mater. Res. Bull., 34(10):1491–1500, 1999. [82] C. N. Xu, T. Watanabe, M. Akiyama, and X. G. Zheng. Artificial skin to sense mechanical stress by visible light emission. Appl. Phys. Lett., 74(9):1236–1238, 1999. [83] D. Olawale, O. Okoli, R. Fontenot, and W. Hollerman. Triboluminescence: Theory, synthesis, and application. Springer International Publishing, 2016. [84] A. Feng and P. F. Smet. A Review of Mechanoluminescence in Inorganic Solids: Compounds, Mechanisms, Models and Applications. Materials (Basel, Switzerland), 11(4), mar 2018. [85] P. Jongchansitto, D. Boyer, I. Preechawuttipong, and X. Balandraud. Using Mechanoluminescent Materials to Visualize Interparticle Contact Intensity in Granular Media. Experimental Mechanics, 60(1):51–64, 2020. [86] N. Terasaki, Y. Fujio, S. Horiuchi, H. Akiyama, and M. Itabashi. Mechanoluminescent study for optimization of joint design on cross tension test. The Journal of Adhesion, 98(6):637–646, 2022. [87] B. Chen, D. Peng, P. Lu, Z. Sheng, K. Yan, and Y. Fu. Modeling and validation of mechanoluminescent strain sensing mechanism at quasi-static loading rates. Materials & Design, 226:111588, 2023. [88] Arkema. UviCure S105. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_LambsonCationics/p/ uvicure-s105/, 2019. [89] M. Boyle, C. Martin, and J. Neuner. Epoxy Resins. In Composites, volume 21. ASM International, 2001. [90] K. B. Tator. Epoxy Resins and Curatives. In Protective Organic Coatings, volume 5B. ASM International, 2015. [91] J. Crivello. Investigations of the reactivity of “kick-started” oxetanes in photoinitiated cationic polymerization. J. Polym. Sci. Part A Polym. Chem., 53(4):586–593, 2015. [92] Arkema. UviCure S140. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_LambsonCationics/p/ uvicure-s140/, 2019. [93] J. Crivello. The discovery and development of onium salt cationic photoinitiators. J. Polym. Sci. Part A Polym. Chem., 37(23):4241 – 4254, 1999. [94] Arkema. SpeedCure 992. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_Lambson/p/speedcure- 992/, 2019. [95] Y. Yagci, S. Jockusch, and N. J. Turro. Photoinitiated Polymerization: Advances, Challenges, and Opportunities. Macromolecules, 43(15):6245–6260, 2010. [96] M. Sangermano, I. Roppolo, and A. Chiappone. New Horizons in Cationic Photopolymerization. Polymers (Basel)., 10(2):136, jan 2018. [97] Arkema. UviCure S128. Technical Data Sheet. Retrieved from https: //americas.sartomer.arkema.com/en/product-finders/product/f/sartomer_ LambsonCationics/p/uvicure-s128/, 2019. [98] Arkema. UviCure S160. Technical Data Sheet. Retrieved from https: //americas.sartomer.arkema.com/en/product-finders/product/f/sartomer_ LambsonCationics/p/uvicure-s160/, 2019. [99] Arkema. UviCure S150. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_LambsonCationics/p/ uvicure-s150/, 2019. [100] Arkema. UviCure S130. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_LambsonCationics/p/ uvicure-s130/, 2019. [101] Arkema. SpeedCure 976. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_Lambson/p/speedcure- 976/, 2019. [102] Arkema. UviCure and SpeedCure. https://emea.sartomer.arkema.com/en/ Accessed 05/04/2023. [103] Q-Lab Corporation. Specification Bulletin LP-0862-A: Q-panel - Steel and Iron Phosphated Panels, 2018. [104] RK PrintCoat Instruments Ltd. K Hand Coater. Retrieved from https://www.rkprint. com/wp-content/uploads/2018/02/New-K-HAND-COATER.pdf, Accessed 20/06/2023. [105] Dymax. UVC - 5 Manual and Technical Data. Retrieved from https://dymax.com/images/ pdf/manuals/man088eu_uvc-5_conveyor_user_guide.pdf, 2015. [106] Jenton Group. Flexible Solutions for Modular UV Curing. Retrieved from http://www.jentonconverting.co.uk/index_html_files/Jenton_UV_Brochure_ 31012011.pdf, (n.d). [107] D. Lam and M. W. Ellens. Photoelastic coating for structural monitoring. Retrieved from https://patents.google.com/patent/US8432537B2/en, 2013. [108] American coatings association. Optimum Viscosity for Paint Application. Retrieved from https://www.paint.org/coatingstech-magazine/articles/optimum-viscositypaint- application/#:~:text=There%20is%20a%20rule%20of,%2C%20brushing%2C% 20or%20roll%20coating., Accessed 17/04/2023. [109] Lechler GmbH. Atomization methods. Retrieved from https://www.lechler.com/de-en/technology/basics-nozzle-technology/ atomization-methods., Accessed 17/04/2023. [110] C Yuangyai and H B Nembhard. Design of Experiments: A Key to Innovation in Nanotechnology. In Emerging Nanotechnologies for Manufacturing, Micro and Nano Technologies, pages 207–234. William Andrew Publishing, Boston, 2010. [111] R. Kent. Design quality management. In Quality Management in Plastics Processing, pages 227–262. Elsevier, 2016. [112] Minitab. Design of experiment statisical software. Retrieved from https://www.minitab. com/en-us/, Accessed on 10/02/2020. [113] Vishay Precision Group: Micro Measurements. Calibration of Photostress Coatings: Tech Note TN-701-1. Retrieved from http://www.vishaypg.com/docs/11211/11211_te.pdf, 2011. [114] SPOTS Project. Good Practice Guide to Reflection Photoelasticity. Calibration and Assessment of Optical Strain Measurements, 2005. [115] Omega. 3 element 0/45/90 planar, compact rosette strain gauges. Retrieved from https://www.omega.com/en-us/force-strain-measurement/straingauges/ rosette-strain-gauges/p/SGD-3-ELEMENT45. [116] National Instruments. NI-9235 C Series Strain/Bridge Input Module. Retrieved from https: //www.ni.com/en-gb/support/model.ni-9235.html. [117] RK PrintCoat Instruments Ltd. K Control Coater. Retrieved from https://www.rkprint. com/products/k-control-coater/. [118] R. Schaefer. Mechanical Properties of Rubber. In Harris’ Shock and Vibration Handbook, chapter 33. 2002. [119] A. N. Gent and R. P. Campion. Engineering with Rubber: How to Design Rubber Components. Engineering with Rubber: How to Design Rubber Components. Hanser, 2001. [120] X. Fernández-Francos, S. Kazarian, X. Ramis, and A. Serra. Simultaneous Monitoring of Curing Shrinkage and Degree of Cure of Thermosets by Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy. Applied spectroscopy, 67:1427–1436, 2013. [121] Arkema. Arkema’s Photoinitiator Centre of Excellence. https://sartomer.arkema. com/en/innovations/collaborative-partnerships/photoinitiator-center-ofexcellence/ Accessed 18/05/2023. [122] ThermoFisher Scientific. Nicolet™ iS50 FTIR Spectrometer. Retrieved from https://www. thermofisher.com/order/catalog/product/912A0760, Accessed 22/10/2021. [123] Specac. Golden Gate Diamond ATR Datasheet. Retrieved from https://www.specac.com/ en/documents/data-sheets/golden-gate-datasheet, Accessed 22/10/2021. [124] Excelitas. OmniCure S2000 Spot UV Curing System. [125] Lambson. SpeedCure 976. Retrieved from https://www.lambson.com/_documents/tds/ speedcure_976.pdf, 2020. [126] W. Ji. Error analysis and system improvements in phase-stepping methods for photoelasticity. 1998. [127] Hammerite - AkzoNobel. Direct to Rust Metal Paint Aerosol Smooth Finish. Retrieved from https://www.hammerite.co.uk/product/direct-to-rust-metal-paint-aerosolsmooth- finish/, Accessed 30/05/2023. [128] Matweb. Aluminium 6082-T6 datasheet. Retrieved from http://www.matweb.com/search/ datasheet_print.aspx?matguid=fad29be6e64d4e95a241690f1f6e1eb7. [129] Ocean Insight. High resolution spectrometers. Retrieved from https://www.oceaninsight.com/products/spectrometers/high-resolution/, Accessed 31/05/2023. [130] Resin8. Transparent Red Tint. https://www.resin8.co.uk/collections/transparenttint/ products/transparent-tint-red?variant=41105454071988, Accessed on 09/16/2022. [131] Gary Cloud. Photoelasticity methods and applications, pages 101–144. Cambridge University Press, 1995. [132] Vishay Precision Group: Micro Measurements. General purpose strain gages - Rectangular Rosette. Retrieved from http://www.vishaypg.com/docs/11077/060wr.pdf, 2015. [133] Micro-measurementsl. P3 Strain Indicator and Recorder. Retrieved from https://micro-measurements.com/pca/detail/p3-strain-indicator-andrecorder, Accessed 13/06/2023. [134] Vishay Precision Group: Micro Measurements. Two-element 90 deg tee rosette for general-purpose use. Retrieved from https://micro-measurements.com/pca/detail/ 125uta, Accessed 30/06/2023. [135] Jochum Beetsma. Coating film defects. Retrieved from https://www.ulprospector.com/knowledge/451/pc-coating-film-defects/, Accessed 20/06/2023. [136] R. J. Greene and E. A. Patterson. An Integrated Approach to the Separation of Principal Surface Stresses Using Combined Thermo-Photo-Elasticity. Experimental Mechanics, 46(1):19–29, 2006. [137] Edmund Optics. BARIUM AND STRONTIUM PRODUCTS. Retrieved from https: //www.sakai-chem.co.jp/en/products_services_barium_strontium.php, Accessed 30/06/2023. [138] N. Terasaki, C. Xu, Y. Imai, and H. Yamada. Photocell System Driven by Mechanoluminescence. Japanese Journal of Applied Physics, 46(4B):2385–2388, apr 2007. [139] H. Zhang, N. Terasaki, H. Yamada, and C. Xu. Mechanoluminescence of europium-doped SrAMgSi2O7 (A = Ca, Sr, Ba). Jpn. J. Appl. Phys., 48(4 PART 2):04C109–1 – 04C109–4, apr 2009. [140] Y. Jia, M. Yei, and W. Jia. Stress-induced mechanoluminescence in SrAl2O4:Eu2+,Dy3+. Opt. Mater. (Amst)., 28(8):974–979, 2006. [141] Inc Thorlabs. CS505MU CMOS Camera. Retrieved from https://www.thorlabs.com/ thorproduct.cfm?partnumber=CS505MU, Accessed on 11/10/2022. [142] ImageJ. Register virtual stack slices - Image Jplugin. Retrieved from https://imagej.net/ plugins/register-virtual-stack-slices, Accessed on 11/10/2022. [143] Nemoto & co., Ltd. Phosphorescent pigments. Retrieved from https://www.nemoto.co. jp/en/luminouspigment/, Accessed 23/06/2023. [144] I. Arganda-Carreras, C. O. S. Sorzano, R Marabini, J. M. Carazo, C. Ortiz-de Solorzano, and J. Kybic. Consistent and Elastic Registration of Histological Sections Using Vector-Spline Regularization. In Reinhard R Beichel and Milan Sonka, editors, Computer Vision Approaches to Medical Image Analysis, pages 85–95, Berlin, Heidelberg, 2006. Springer Berlin Heidelberg. [145] W. Wang, W. Widiyastuti, T. Ogi, I. W. Lenggoro, and K. Okuyama. Correlations between Crystallite/Particle Size and Photoluminescence Properties of Submicrometer Phosphors. Chemistry of Materials, 19(7):1723–1730, 2007. [146] Y. Kim and S. Kang. Effect of particle size on photoluminescence emission intensity in ZnO. Acta Materialia, 59(8):3024–3031, 2011. [147] JEOL Ltd. Phosphorescent pigments. Retrieved from https://www.jeol.com/products/ scientific/sem/JSM-6010LA.php, Accessed 26/06/2023. [148] Thorlabs, Inc. Hard-Coated Edgepass Filters. Retrieved from https://www.thorlabs.com/ newgrouppage9.cfm?objectgroup_id=6082&pn=FESH0600, Accessed 26/06/2023. [149] Edmund Optics. SCHOTT RG-630, 50mm Dia., 3mm Thick, Colored Glass Longpass Filter. Retrieved from https://www.edmundoptics.co.uk/p/rg-630-50mmdia- longpass-filter/20628/, Accessed 26/06/2023. [150] Stress Photonics Inc. https://glassphotonics.com/all-products/grey-fieldpolariscopes/, Accessed on 08/04/2020. [151] AMETEK Brookfield. Dial Reading Viscometer. Retrieved from https://www.brookfieldengineering.com/products/viscometers/laboratoryviscometers/ dial-reading-viscometer, Accessed 17/04/2023. [152] C. Kallendorf, D. Cyterski, A. Spinks, and D. Dreifus. D3359 - 87: Measuring Adhesion by Tape Test. In Radiation Curing Test Methods, pages 339 – 343. RadTech International, Cincinnati, 1988. [153] Tinius Olsen. Model 5ST: Electromechanical Testing Machine. Retrieved from https:// www.tiniusolsen.com/product/model-5st/, Accessed on 18/04/2023. [154] TA Instruments. DSC 25. https://www.tainstruments.com/dsc-25/, Accessed on 06/01/2019. [155] P. Gill, T. T. Moghadam, and B. Ranjbar. Differential scanning calorimetry techniques: applications in biology and nanoscience. Journal of biomolecular techniques : JBT, 21(4):167–193, 2010. [156] ThermoFisher Scientific. Nicolet™ iS™ 10 FTIR Spectrometer. Retrieved from https://www.thermofisher.com/order/catalog/product/IQLAADGAAGFAHDMAPC, Accessed 22/10/2021. [157] ASTM International. D523 - 14 Standard Test Method For Specular Gloss, 2018."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/R513313/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/34106/1/Fraser.%20William%2C%20190207623.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Reflection Photoelastic Stress Analysis (RPSA) is an experimental technique used in industries to assist in a variety of design and manufacture processes. Users can benefit from immediate qualitative and quantitative information, for example, about maximum shear strains in complex geometries. One such user of RPSA, and the focus of this research, is Airbus that perform RPSA within the manufacturing process of their aircraft wing assemblies. Although insightful, RPSA procedures suffer from complicated application processes, a need for skilled engineers and large timescales for data collection. These issues all stem from one vital component — the photoelastic coating material. Common commercially available RPSA coatings are designed in such a way to compensate for failings in RPSA apparatus that were once insensitive to small changes in component surface strain. However, current commercially available automated photoelastic collection and analysis apparatus have given the potential for RPSA to be a truly effective method. This is due to high detection sensitivity of better than 0.1 nm that translates to a 20 micro strain resolution. RPSA techniques could benefit and compensate for using easy to apply, thinner (approximately 50 microns) but less sensitive coatings. As a result, this research aims to investigate and develop a novel, time-efficient and `smart' coating material that updates current RPSA methods. Whilst applications at Airbus are the focus of this research the wider applicability of this coating is extensive. Within this thesis, the key criteria for the new coating are outlined and explained by reviewing relevant theory, literature and all conducted experimental research. Coating development is divided into two main investigative topics: reflection photoelasticity (RPE) and mechanoluminescence (ML). The RPE development topic utilised a range of UV curable resins that were rationally designed into an optimum formulation. The coating was designed and tested with the automated RPE imaging device — the Grey Field Polariscope (GFP). The choice of UV curable materials provides a new range of rapid application coatings boasting a 20 s cure time whilst possessing similar RPE sensitivities of existing commercial products. Additionally, the coating was designed with thickness correction capabilities within post-processing to further promote the ease of use of the coating. By introducing a red tint to the formulation and imaging with the GFP, it was shown that thickness differences could be corrected in order to provide accurate RPSA data. At targetted thicknesses of 50 microns, correction by manipulation of different wavelengths of light has not been attempted before. Performing calibration experiments, the clear (WF31) and red tinted (WF-Red1) UV curable materials possessed strain-optic coefficients indicative of medium-high sensitivity coatings (K = 0.8 - 0.1). The ML topic investigated the introduction of a mechanoluminescent phosphor to the developed UV curable formulation to produce a novel dual-technique strain imaging coating. ML materials generate light under the influence of strain with the intensity able to provide a map of the surface's strain field. The objective was to capture the production of ML light whilst performing RPE simultaneously in order to provide additional information that would support both techniques. The commonly researched ML material strontium aluminate was utilised and was added at a 30 % weight percentage to the optimised UV curable formulation. It was demonstrated for the first time that concurrent measurement of both techniques was possible by filtering the green ML light against RPE performed monochromatically using red light. Qualitative comparisons demonstrated it utility, however challenges utilising ML within elastic conditions limits it use. Firstly, it was observed that the ML coating had a `one-shot' application with the intensity of produced light diminishing with subsequent loads. This was a result of the ML phosphor debonding with the carrier resin. Additionally, the light production within elastic conditions was poor requiring high strain rates to produce observable conditions. As a result, eliminating all ambient light is a prerequisite for successful application. However, ML demonstrated relativity high light intensities when at areas of high strain, singularities, and when the component breached its elastic limit. Therefore, it has been shown that ML's potentially usefulness could be a validation technique to go alongside photoelasticity. The research has successfully demonstrated the high performance of a new reflection coating with the ability for application, data collection and processing, and coating removal to be performed in one single day — an order of magnitude better than existing techniques. Combination with ML materials for simultaneous RPE and ML capture has been demonstrated with the ability for RPE validation however not without difficulties. However, a novel technique/apparatus has been designed and implemented which allows for the first time PE and ML data to be measured simultaneously."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of Novel Coatings for Full Field Strain Measurements"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tomlinson, Rachel","Parnell, Andrew"],"dc:contributor.sponsor":["EPSRC Doctoral Training Partnership (DTP) Scholarship"],"dc:creator":["Fraser, William"],"dc:date":["2023-07"],"dc:date.issued":["2023-07"],"dc:description.abstract":["Reflection Photoelastic Stress Analysis (RPSA) is an experimental technique used in industries to assist in a variety of design and manufacture processes. Users can benefit from immediate qualitative and quantitative information, for example, about maximum shear strains in complex geometries. One such user of RPSA, and the focus of this research, is Airbus that perform RPSA within the manufacturing process of their aircraft wing assemblies. Although insightful, RPSA procedures suffer from complicated application processes, a need for skilled engineers and large timescales for data collection. These issues all stem from one vital component — the photoelastic coating material. Common commercially available RPSA coatings are designed in such a way to compensate for failings in RPSA apparatus that were once insensitive to small changes in component surface strain. However, current commercially available automated photoelastic collection and analysis apparatus have given the potential for RPSA to be a truly effective method. This is due to high detection sensitivity of better than 0.1 nm that translates to a 20 micro strain resolution. RPSA techniques could benefit and compensate for using easy to apply, thinner (approximately 50 microns) but less sensitive coatings. As a result, this research aims to investigate and develop a novel, time-efficient and `smart' coating material that updates current RPSA methods. Whilst applications at Airbus are the focus of this research the wider applicability of this coating is extensive. Within this thesis, the key criteria for the new coating are outlined and explained by reviewing relevant theory, literature and all conducted experimental research. Coating development is divided into two main investigative topics: reflection photoelasticity (RPE) and mechanoluminescence (ML). The RPE development topic utilised a range of UV curable resins that were rationally designed into an optimum formulation. The coating was designed and tested with the automated RPE imaging device — the Grey Field Polariscope (GFP). The choice of UV curable materials provides a new range of rapid application coatings boasting a 20 s cure time whilst possessing similar RPE sensitivities of existing commercial products. Additionally, the coating was designed with thickness correction capabilities within post-processing to further promote the ease of use of the coating. By introducing a red tint to the formulation and imaging with the GFP, it was shown that thickness differences could be corrected in order to provide accurate RPSA data. At targetted thicknesses of 50 microns, correction by manipulation of different wavelengths of light has not been attempted before. Performing calibration experiments, the clear (WF31) and red tinted (WF-Red1) UV curable materials possessed strain-optic coefficients indicative of medium-high sensitivity coatings (K = 0.8 - 0.1). The ML topic investigated the introduction of a mechanoluminescent phosphor to the developed UV curable formulation to produce a novel dual-technique strain imaging coating. ML materials generate light under the influence of strain with the intensity able to provide a map of the surface's strain field. The objective was to capture the production of ML light whilst performing RPE simultaneously in order to provide additional information that would support both techniques. The commonly researched ML material strontium aluminate was utilised and was added at a 30 % weight percentage to the optimised UV curable formulation. It was demonstrated for the first time that concurrent measurement of both techniques was possible by filtering the green ML light against RPE performed monochromatically using red light. Qualitative comparisons demonstrated it utility, however challenges utilising ML within elastic conditions limits it use. Firstly, it was observed that the ML coating had a `one-shot' application with the intensity of produced light diminishing with subsequent loads. This was a result of the ML phosphor debonding with the carrier resin. Additionally, the light production within elastic conditions was poor requiring high strain rates to produce observable conditions. As a result, eliminating all ambient light is a prerequisite for successful application. However, ML demonstrated relativity high light intensities when at areas of high strain, singularities, and when the component breached its elastic limit. Therefore, it has been shown that ML's potentially usefulness could be a validation technique to go alongside photoelasticity. The research has successfully demonstrated the high performance of a new reflection coating with the ability for application, data collection and processing, and coating removal to be performed in one single day — an order of magnitude better than existing techniques. Combination with ML materials for simultaneous RPE and ML capture has been demonstrated with the ability for RPE validation however not without difficulties. However, a novel technique/apparatus has been designed and implemented which allows for the first time PE and ML data to be measured simultaneously."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/R513313/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/34106/1/Fraser.%20William%2C%20190207623.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Mechanical Engineering (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/34106/"],"dc:relation.references":["[1] E. Hearn. Mechanics of Materials 2: An introduction to the Mechanics of Elastic and Plastic Deformation of Solids and Structural Materials, volume 3. Butterworth-Heinemann, 1997. [2] K. Ramesh. Photoelasticity, pages 701–742. Springer US, Boston, MA, 2008. [3] K. Ramesh. Digital Photoelasticity: Advanced Techniques and Applications. Springer Berlin Heidelberg, 2000. [4] G. Calvert, J. Lesniak, and M. Honlet. Applications of modern automated photoelasticity to industrial problems. Insight, 44(4):224–227, 2002. [5] B. Neethi Simon and K. Ramesh. A Simple Method to Plot Photoelastic Fringes and Phasemaps from Finite Element Results. Journal of Aerospace Sciences and Technologies, 62(3), 2010. [6] M. Geramizadeh, H. Katoozian, R. Amid, and M. Kadkhodazadeh. Comparison of finite element results with photoelastic stress analysis around dental implants with different threads. Dental and medical problems, 55(1):17–22, 2018. [7] Vishay Precision Group: Micro Measurements. PhotoStress Coating Materials and Adhesives. Retrieved from http://www.vishaypg.com/docs/11222/pscoat.pdf, 2015. [8] B. E. Foust, J. R. Lesniak, and R. E. Rowlands. Stress analysis of a pinned wood joint by grey-field photoelasticity. Composites Part B: Engineering, 61:291–299, 2014. [9] J. Hubner, J. Nicolosi, L. Chen, P. Ifju, and W. El-Ratal. Oblique incidence response of photoelastic coatings. Experimental Techniques, 29(3):52–56, 2005. [10] J. P. Hubner, P. G. Ifju, K. S. Schanze, Y. Liu, L. Chen, and W. El-Ratal. Luminescent photoelastic coatings. Experimental Mechanics, 44(4):416–424, 2004. [11] Vishay Precision Group: Micro Measurements. Instructions for Casting and Contouring PhotoStress Sheets: Application note B-221. Retrieved from http://www.vishaypg.com/ docs/11221/ib-221.pdf, 2015. [12] Vishay Precision Group: Micro Measurements. Instructions for Bonding Flat and Contoured PhotoStress Sheets: Application Note B-223. Retrieved from http://www.vishaypg.com/ docs/11223/ib-223ib.pdf, 2015. [13] Airbus. A320ceo. https://aircraft.airbus.com/en/aircraft/a320-the-mostsuccessful- aircraft-family-ever/a320ceo Date Accessed 03/04/2023. [14] J. Lesniak and M. Zickel. Applications of automated grey-field polariscope. In Proceedings of the 1998 SEM Spring Conference on Experimental Mechanics, pages 298–301, Houston, Texas, 1998. [15] H. D. Young, R. A. Freedman, F. W. Sears, and M. W. Zemansky. Sears and Zemansky’s university physics : with modern physics technology update. Pearson Education, Harlow, Essex, thirteenth edition, 2014. [16] E. Hecht. Optics. Pearson, 5th edition, 2017. [17] M. Bass, E. W. V. Stryland, D. R. Williams, and W. L. Wolfe. Handbook of Optics Volume II Devices, Measurements, and Properties. McGraw-Hill Professional, 2nd edition, 1995. [18] J. Pavlin, N. Vaupotič, and M. Čepič. Direction dependence of the extraordinary refraction index in uniaxial nematic liquid crystals. Eur. J. Phys., 34(2):331–344, jan 2013. [19] E. Wolf and M. Born. Principle of Optics. Pergamon Press, 5th edition, 1975. [20] A. Praveen, Z. Weijun, and R. Raghunath. Photoelastic birefringence of copolymers with non-planar structure. Polymer (Guildf)., 164:217–222, 2019. [21] D. Harrington and S. Sueoka. Polarization modeling and predictions for DKIST part 3: focal ratio and thermal dependencies of spectral polarization fringes and optic retardance. J. Astron. Telesc. Instruments, Syst., 4(1), 2018. [22] F. El-Diasty, M. A. Soliman, A. F. T. Elgendy, and A. Ashour. Birefringence dispersion in uniaxial material irradiated by gamma rays: cellulose triacetate films. J. Opt. A Pure Appl. Opt., 9(3):247–252, feb 2007. [23] G. Cloud. Optical methods in experimental mechanics - Part 29: Photoelasticity I - Birefringence and relative retardation. Exp. Tech., 31(6):27–29, 2007. [24] P. Theocaris and E. Gdoutos. Two-Dimensional Photoelasticity, page 113. Springer Berlin Heidelberg, Berlin, Heidelberg, 1979. [25] G. H. Ryder. Strength of materials. The Macmillan Press Ltd, 3rd edition, 1969. [26] T. H. G. Megson. Structural and stress analysis. Elsevier Butterworth-Heinemann, 2nd edition, 2005. [27] G. Cloud. Optical Methods in Experimental Mechanics - Part 30: Photoelasticity II - Birefringence in Materials. Exp. Tech., 32(1):13–16, 2008. [28] Tadashi Inoue. Strain-Induced Birefringence of Amorphous Polymers and Molecular Design of Optical Polymers. ACS Applied Polymer Materials, 3(5):2264–2273, 2021. [29] T. Freegarde. Introduction to the Physics of Waves. Cambridge University Press, 2012. [30] P. Hariharan. Basics of interferometry. Elsevier Academic Press, 2nd edition, 2006. [31] K. Ramesh. Photoelasticity. In Springer Handbook Experimental Solid Mechanics, pages 701 – 742. Springer, 2008. [32] M. Ramji and K. Ramesh. Whole field evaluation of stress components in digital photoelasticity - Issues, implementation and application. Opt. Lasers Eng., 46(3):257–271, 2008. [33] E. A. Patterson. Digital Photoelasticity: Principles, Practice and Potential. Strain, 38(1):27–39, 2002. [34] K. Ramesh and S. Sasikumar. Digital photoelasticity: Recent developments and diverse applications. Optics and Lasers in Engineering, 135, 2020. [35] F. W. Hecker and B. Morche. Computer-Aided Measurement of Relative Retardations in Plane Photoelasticity. In H Wieringa, editor, Exp. Stress Anal., pages 535–542, Dordrecht, 1986. Springer Netherlands. [36] E. A. Patterson and Z. F. Wang. Towards full field automated photoelastic analysis of complex components. Strain, 27(2):49–53, 1991. [37] A. Asundi, L. Tong, and C. Boay. Phase-shifting method with a normal polariscope. Appl. Opt., 38(28):5931–5935, oct 1999. [38] Z. F. Wang and E. A. Patterson. Use of phase-stepping with demodulation and fuzzy sets for birefringence measurement. Opt. Lasers Eng., 22(2):91–104, 1995. [39] W. Ji and E. Patterson. Simulation of errors in automated photoelasticity. Exp. Mech., 38(2):132–139, 1998. [40] M. Ramji and K. Ramesh. Stress separation in digital photoelasticity part a-photoelastic data unwrapping and smoothing. Journal of Aerospace Sciences and Technologies, pages 5–15, 2008. [41] G. M. Brown and J. L. Sullivan. The computer-aided holophotoelastic method. Experimental Mechanics, 30(2):135–144, 1990. [42] A. Ajovalasit, S. Barone, and G. Petrucci. A method for reducing the influence of quarter-wave plate errors in phase stepping photoelasticity. J. Strain Anal. Eng. Des., 33(3):207–216, 1998. [43] G. Cloud. Optical Methods in Experimental Mechanics Part 38: Photoelasticity X—Transfer of Stress Data From Model to Prototype. Exp. Tech., 33(5), 2008. [44] K. Ramesh. Basics of photoelasticity and photoplasticity. In Developments in Photoelasticity, 2053-2563, pages 1–41. IOP Publishing, 2021. [45] Vishay Precision Group: Micro Measurements. Corrections to Photoelastic Coating Fringe-Order Measurements: Technical Note TN-706-1. Retrieved from https://docs. micro-measurements.com/?id=2536, 2015. [46] E. A. Patterson and Z. F. Wang. Simultaneous observation of phase-stepped images for automated photoelasticity. J. Strain Anal. Eng. Des., 33(1):1–15, 1998. [47] J. Lesniak, S. J. Zhang, and E. A. Patterson. Design and evaluation of the poleidoscope: A novel digital polariscope. Exp. Mech., 44(2):128–135, 2004. [48] J. W. Hobbs, R. J. Greene, and E. A. Patterson. A novel instrument for transient photoelasticity. Experimental Mechanics, 43(4):403–409, 2003. [49] J. Lesniak, M. Zickel, and C. W. D. Johnson. An Innovative Polariscope for Photoelastic Stress Analysis. In Proc. 1997 SEM Spring Conf. Exp. Mech., pages 219 – 224, 1997. [50] Stress Photonics Inc. GFP1400 Operator’s Manual, 2014. [51] M. Mesnager. Sur la Determination Optique des Tensions Interieures dans les Solides a Trois Dimensions (French) [On the Optical Determination of Interior Tensions in Three Dimensional Solids]. Comptes Rendus, (190):1249, 1930. [52] Engineering ToolBox. Young’s Modulus - Tensile and Yield Strength for common Materials. https://www.engineeringtoolbox.com/young-modulus-d_417.html Date Accessed 30/12/2019, 2003. [53] F. Zandman, S. Redner, and J. W. Dally. Photoelastic coatings. Society for Experimental Stress Analysis. SESA monograph ; no. 3. Iowa State University Press, Ames, 1977. [54] S. Paipetis. Photoelasticity in engineering practice - Conventional Three-Dimensional Photoelasticity: A Review of Principles and Materials. Elsevier Applied Science, London, 1985. [55] G. Cloud. Optical Methods in Experimental Mechanics - Part 42: Photoelasticity XIV - Reflection Photoelasticity. Experimental Techniques, 34(4):15 – 19, 2010. [56] ITW Performance Polymers. Devcon 2 Ton®Epoxy Technical Data Sheet. Retrieved from https://itwperformancepolymers.com/wp-content/uploads/umb/1008/2-tonepoxy_ 041318.pdf, 2018. [57] D. Lam and M. W. Ellens. Method for detecting stress and strain. Retrieved from https: //patents.google.com/patent/US6650405B2/en, 2001. [58] F. Zandman. Stress Analysis of a Guided Missile Tail Section with the Photoelastic Technique. In SESA, volume 17, pages 135 – 150, 1960. [59] B. Kenny and J. W. Hugill. Comparison of Fringe Multiplication and Tardy Compensation Methods for a Frozen Stress Investigation. Strain, 3(1):3–7, 1967. [60] G. H. Staab and T. G. Richard. An experimental investigation of cog-root strains in V-belts using birefringent coatings. Exp. Mech., 22(12):476–480, dec 1982. [61] B. E. Foust, J. R. Lesniak, and R. E. Rowlands. Determining Individual Stresses Throughout a Pinned Aluminum Joint by Reflective Photoelasticity. Experimental Mechanics, 51(9):1441–1452, 2011. [62] J. Hubner, L. Chen, Y. Liu, K. Schanze, P. Ifju, J. Nicolosi, and W. El-Ratal. Characterization of a new luminescent photoelastic coating. Experimental Mechanics, 45(2):137–143, 2005. [63] J. Hubner, S. Jiang, Y. Liu, K. Schanze, P. Ifju, D. A. Jenkins, and W. El-Ratal. Method and apparatus for measuring strain using a luminescent photoelastic coating . Retrieved from https://patents.google.com/patent/US20040066503A1/en, 2004. [64] F. Bacon. Of the advancement of learning. J. M. Dent & sons, 1915. [65] B. P. Chandra. Mechanoluminescence. In D. R. Vij, editor, Luminescence of Solids, pages 361–389. Springer US, Boston, MA, 1998. [66] N. C. Eddingsaas and K. S. Suslick. Light from sonication of crystal slurries. Nature, 444(7116):163, 2006. [67] A. Feng, S. Michels, A. Lamberti, and P. F. Smet. Mechanoluminescent Materials: A New Way to Analyze Stress by Light. Proceedings, 2(8):492, 2018. [68] D. O. Olawale, T. Dickens, W. G. Sullivan, O. I. Okoli, J. O. Sobanjo, and B. Wang. Progress in triboluminescence-based smart optical sensor system. J. Lumin., 131(7):1407 – 1418, 2011. [69] B. P. Chandra, R. N. Baghel, and V. K. Chandra. Mechanoluminescence glow curve of ZnS:Mn. Chalcogenide Lett., 7(1):1–9, 2010. [70] B P Chandra, V K Chandra, and Piyush Jha. Microscopic theory of elastico-mechanoluminescent smart materials. Appl. Phys. Lett., 104(3), 2014. [71] C. Li, C. Xu, L. Zhang, H. Yamada, and Y. Imai. Dynamic visualization of stress distribution on metal by mechanoluminescence images. J. Vis., 11(4):329–335, 2008. [72] V K Chandra and B P Chandra. Dynamics of the mechanoluminescence induced by elastic deformation of persistent luminescent crystals. Journal of Luminescence, 132(3):858–869, 2012. [73] H. Zhang, H. Yamada, N. Terasaki, and C. Xu. Ultraviolet mechanoluminescence from SrAl2O4:Ce and SrAl2O4:Ce,Ho. Applied Physics Letters, 91(8), aug 2007. [74] W. Wang, T. Matsubara, Y. Takao, Y. Imai, and C. Xu. Visualization of Stress Distribution Using Smart Mechanoluminescence Sensor. Mater. Sci. Forum, 614:169–174, 2009. [75] S. Timilsina, K. H. Lee, I. Y. Jang, and J. S. Kim. Mechanoluminescent determination of the mode I stress intensity factor in SrAl2O4:Eu2+,Dy3+. Acta Materialia, 61(19):7197–7206, 2013. [76] G. J. Yun, M. R. Rahimi, A. H. Gandomi, G. Lim, and J. Choi. Stress sensing performance using mechanoluminescence of SrAl 2 O 4 :Eu (SAOE) and SrAl 2 O 4 :Eu, Dy (SAOED) under mechanical loadings. Smart Materials and Structures, 22(5):055006, 2013. [77] V. K. Chandra and B. P. Chandra. Suitable materials for elastico mechanoluminescence-based stress sensors. Optical Materials, 34(1):194–200, 2011. [78] A.F. Banishev and A.A. Banishev. Deformation Stimulated Luminescence of a Composite Produced on the Basis of Polymethylmethacrylate Transparent in the Visible Region and Finely Dispersed Powder of SrAl2O4:(Eu2+, Dy3+) Phosphor. Inorg. Mater. Appl. Res., 10:647 – 651, 2019. [79] A. I. Azad, M. R. Rahimi, and G. J. Yun. Quantitative full-field strain measurements by SAOED (SrAl2O4:Eu2+,Dy3+) mechanoluminescent materials. Smart Materials and Structures, 25(9):95032, 2016. [80] K. Kanamaru and H. Utsunomiya. In-situ observation of nonuniform deformation during tensile test of aluminum alloy sheet by means of screen-printed mechanoluminescence film. Scripta Materialia, 209:114388, 2022. [81] C. N. Xu, T. Watanabe, M. Akiyama, and X. G. Zheng. Preparation and characteristics of highly triboluminescent ZnS film. Mater. Res. Bull., 34(10):1491–1500, 1999. [82] C. N. Xu, T. Watanabe, M. Akiyama, and X. G. Zheng. Artificial skin to sense mechanical stress by visible light emission. Appl. Phys. Lett., 74(9):1236–1238, 1999. [83] D. Olawale, O. Okoli, R. Fontenot, and W. Hollerman. Triboluminescence: Theory, synthesis, and application. Springer International Publishing, 2016. [84] A. Feng and P. F. Smet. A Review of Mechanoluminescence in Inorganic Solids: Compounds, Mechanisms, Models and Applications. Materials (Basel, Switzerland), 11(4), mar 2018. [85] P. Jongchansitto, D. Boyer, I. Preechawuttipong, and X. Balandraud. Using Mechanoluminescent Materials to Visualize Interparticle Contact Intensity in Granular Media. Experimental Mechanics, 60(1):51–64, 2020. [86] N. Terasaki, Y. Fujio, S. Horiuchi, H. Akiyama, and M. Itabashi. Mechanoluminescent study for optimization of joint design on cross tension test. The Journal of Adhesion, 98(6):637–646, 2022. [87] B. Chen, D. Peng, P. Lu, Z. Sheng, K. Yan, and Y. Fu. Modeling and validation of mechanoluminescent strain sensing mechanism at quasi-static loading rates. Materials & Design, 226:111588, 2023. [88] Arkema. UviCure S105. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_LambsonCationics/p/ uvicure-s105/, 2019. [89] M. Boyle, C. Martin, and J. Neuner. Epoxy Resins. In Composites, volume 21. ASM International, 2001. [90] K. B. Tator. Epoxy Resins and Curatives. In Protective Organic Coatings, volume 5B. ASM International, 2015. [91] J. Crivello. Investigations of the reactivity of “kick-started” oxetanes in photoinitiated cationic polymerization. J. Polym. Sci. Part A Polym. Chem., 53(4):586–593, 2015. [92] Arkema. UviCure S140. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_LambsonCationics/p/ uvicure-s140/, 2019. [93] J. Crivello. The discovery and development of onium salt cationic photoinitiators. J. Polym. Sci. Part A Polym. Chem., 37(23):4241 – 4254, 1999. [94] Arkema. SpeedCure 992. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_Lambson/p/speedcure- 992/, 2019. [95] Y. Yagci, S. Jockusch, and N. J. Turro. Photoinitiated Polymerization: Advances, Challenges, and Opportunities. Macromolecules, 43(15):6245–6260, 2010. [96] M. Sangermano, I. Roppolo, and A. Chiappone. New Horizons in Cationic Photopolymerization. Polymers (Basel)., 10(2):136, jan 2018. [97] Arkema. UviCure S128. Technical Data Sheet. Retrieved from https: //americas.sartomer.arkema.com/en/product-finders/product/f/sartomer_ LambsonCationics/p/uvicure-s128/, 2019. [98] Arkema. UviCure S160. Technical Data Sheet. Retrieved from https: //americas.sartomer.arkema.com/en/product-finders/product/f/sartomer_ LambsonCationics/p/uvicure-s160/, 2019. [99] Arkema. UviCure S150. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_LambsonCationics/p/ uvicure-s150/, 2019. [100] Arkema. UviCure S130. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_LambsonCationics/p/ uvicure-s130/, 2019. [101] Arkema. SpeedCure 976. Technical Data Sheet. Retrieved from https://emea.sartomer. arkema.com/en/product-finders/product/f/sartomer_Lambson/p/speedcure- 976/, 2019. [102] Arkema. UviCure and SpeedCure. https://emea.sartomer.arkema.com/en/ Accessed 05/04/2023. [103] Q-Lab Corporation. Specification Bulletin LP-0862-A: Q-panel - Steel and Iron Phosphated Panels, 2018. [104] RK PrintCoat Instruments Ltd. K Hand Coater. Retrieved from https://www.rkprint. com/wp-content/uploads/2018/02/New-K-HAND-COATER.pdf, Accessed 20/06/2023. [105] Dymax. UVC - 5 Manual and Technical Data. Retrieved from https://dymax.com/images/ pdf/manuals/man088eu_uvc-5_conveyor_user_guide.pdf, 2015. [106] Jenton Group. Flexible Solutions for Modular UV Curing. Retrieved from http://www.jentonconverting.co.uk/index_html_files/Jenton_UV_Brochure_ 31012011.pdf, (n.d). [107] D. Lam and M. W. Ellens. Photoelastic coating for structural monitoring. Retrieved from https://patents.google.com/patent/US8432537B2/en, 2013. [108] American coatings association. Optimum Viscosity for Paint Application. Retrieved from https://www.paint.org/coatingstech-magazine/articles/optimum-viscositypaint- application/#:~:text=There%20is%20a%20rule%20of,%2C%20brushing%2C% 20or%20roll%20coating., Accessed 17/04/2023. [109] Lechler GmbH. Atomization methods. Retrieved from https://www.lechler.com/de-en/technology/basics-nozzle-technology/ atomization-methods., Accessed 17/04/2023. [110] C Yuangyai and H B Nembhard. Design of Experiments: A Key to Innovation in Nanotechnology. In Emerging Nanotechnologies for Manufacturing, Micro and Nano Technologies, pages 207–234. William Andrew Publishing, Boston, 2010. [111] R. Kent. Design quality management. In Quality Management in Plastics Processing, pages 227–262. Elsevier, 2016. [112] Minitab. Design of experiment statisical software. Retrieved from https://www.minitab. com/en-us/, Accessed on 10/02/2020. [113] Vishay Precision Group: Micro Measurements. Calibration of Photostress Coatings: Tech Note TN-701-1. Retrieved from http://www.vishaypg.com/docs/11211/11211_te.pdf, 2011. [114] SPOTS Project. Good Practice Guide to Reflection Photoelasticity. Calibration and Assessment of Optical Strain Measurements, 2005. [115] Omega. 3 element 0/45/90 planar, compact rosette strain gauges. Retrieved from https://www.omega.com/en-us/force-strain-measurement/straingauges/ rosette-strain-gauges/p/SGD-3-ELEMENT45. [116] National Instruments. NI-9235 C Series Strain/Bridge Input Module. Retrieved from https: //www.ni.com/en-gb/support/model.ni-9235.html. [117] RK PrintCoat Instruments Ltd. K Control Coater. Retrieved from https://www.rkprint. com/products/k-control-coater/. [118] R. Schaefer. Mechanical Properties of Rubber. In Harris’ Shock and Vibration Handbook, chapter 33. 2002. [119] A. N. Gent and R. P. Campion. Engineering with Rubber: How to Design Rubber Components. Engineering with Rubber: How to Design Rubber Components. Hanser, 2001. [120] X. Fernández-Francos, S. Kazarian, X. Ramis, and A. Serra. Simultaneous Monitoring of Curing Shrinkage and Degree of Cure of Thermosets by Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy. Applied spectroscopy, 67:1427–1436, 2013. [121] Arkema. Arkema’s Photoinitiator Centre of Excellence. https://sartomer.arkema. com/en/innovations/collaborative-partnerships/photoinitiator-center-ofexcellence/ Accessed 18/05/2023. [122] ThermoFisher Scientific. Nicolet™ iS50 FTIR Spectrometer. Retrieved from https://www. thermofisher.com/order/catalog/product/912A0760, Accessed 22/10/2021. [123] Specac. Golden Gate Diamond ATR Datasheet. Retrieved from https://www.specac.com/ en/documents/data-sheets/golden-gate-datasheet, Accessed 22/10/2021. [124] Excelitas. OmniCure S2000 Spot UV Curing System. [125] Lambson. SpeedCure 976. Retrieved from https://www.lambson.com/_documents/tds/ speedcure_976.pdf, 2020. [126] W. Ji. Error analysis and system improvements in phase-stepping methods for photoelasticity. 1998. [127] Hammerite - AkzoNobel. Direct to Rust Metal Paint Aerosol Smooth Finish. Retrieved from https://www.hammerite.co.uk/product/direct-to-rust-metal-paint-aerosolsmooth- finish/, Accessed 30/05/2023. [128] Matweb. Aluminium 6082-T6 datasheet. Retrieved from http://www.matweb.com/search/ datasheet_print.aspx?matguid=fad29be6e64d4e95a241690f1f6e1eb7. [129] Ocean Insight. High resolution spectrometers. Retrieved from https://www.oceaninsight.com/products/spectrometers/high-resolution/, Accessed 31/05/2023. [130] Resin8. Transparent Red Tint. https://www.resin8.co.uk/collections/transparenttint/ products/transparent-tint-red?variant=41105454071988, Accessed on 09/16/2022. [131] Gary Cloud. Photoelasticity methods and applications, pages 101–144. Cambridge University Press, 1995. [132] Vishay Precision Group: Micro Measurements. General purpose strain gages - Rectangular Rosette. Retrieved from http://www.vishaypg.com/docs/11077/060wr.pdf, 2015. [133] Micro-measurementsl. P3 Strain Indicator and Recorder. Retrieved from https://micro-measurements.com/pca/detail/p3-strain-indicator-andrecorder, Accessed 13/06/2023. [134] Vishay Precision Group: Micro Measurements. Two-element 90 deg tee rosette for general-purpose use. Retrieved from https://micro-measurements.com/pca/detail/ 125uta, Accessed 30/06/2023. [135] Jochum Beetsma. Coating film defects. Retrieved from https://www.ulprospector.com/knowledge/451/pc-coating-film-defects/, Accessed 20/06/2023. [136] R. J. Greene and E. A. Patterson. An Integrated Approach to the Separation of Principal Surface Stresses Using Combined Thermo-Photo-Elasticity. Experimental Mechanics, 46(1):19–29, 2006. [137] Edmund Optics. BARIUM AND STRONTIUM PRODUCTS. Retrieved from https: //www.sakai-chem.co.jp/en/products_services_barium_strontium.php, Accessed 30/06/2023. [138] N. Terasaki, C. Xu, Y. Imai, and H. Yamada. Photocell System Driven by Mechanoluminescence. Japanese Journal of Applied Physics, 46(4B):2385–2388, apr 2007. [139] H. Zhang, N. Terasaki, H. Yamada, and C. Xu. Mechanoluminescence of europium-doped SrAMgSi2O7 (A = Ca, Sr, Ba). Jpn. J. Appl. Phys., 48(4 PART 2):04C109–1 – 04C109–4, apr 2009. [140] Y. Jia, M. Yei, and W. Jia. Stress-induced mechanoluminescence in SrAl2O4:Eu2+,Dy3+. Opt. Mater. (Amst)., 28(8):974–979, 2006. [141] Inc Thorlabs. CS505MU CMOS Camera. Retrieved from https://www.thorlabs.com/ thorproduct.cfm?partnumber=CS505MU, Accessed on 11/10/2022. [142] ImageJ. Register virtual stack slices - Image Jplugin. Retrieved from https://imagej.net/ plugins/register-virtual-stack-slices, Accessed on 11/10/2022. [143] Nemoto & co., Ltd. Phosphorescent pigments. Retrieved from https://www.nemoto.co. jp/en/luminouspigment/, Accessed 23/06/2023. [144] I. Arganda-Carreras, C. O. S. Sorzano, R Marabini, J. M. Carazo, C. Ortiz-de Solorzano, and J. Kybic. Consistent and Elastic Registration of Histological Sections Using Vector-Spline Regularization. In Reinhard R Beichel and Milan Sonka, editors, Computer Vision Approaches to Medical Image Analysis, pages 85–95, Berlin, Heidelberg, 2006. Springer Berlin Heidelberg. [145] W. Wang, W. Widiyastuti, T. Ogi, I. W. Lenggoro, and K. Okuyama. Correlations between Crystallite/Particle Size and Photoluminescence Properties of Submicrometer Phosphors. Chemistry of Materials, 19(7):1723–1730, 2007. [146] Y. Kim and S. Kang. Effect of particle size on photoluminescence emission intensity in ZnO. Acta Materialia, 59(8):3024–3031, 2011. [147] JEOL Ltd. Phosphorescent pigments. Retrieved from https://www.jeol.com/products/ scientific/sem/JSM-6010LA.php, Accessed 26/06/2023. [148] Thorlabs, Inc. Hard-Coated Edgepass Filters. Retrieved from https://www.thorlabs.com/ newgrouppage9.cfm?objectgroup_id=6082&pn=FESH0600, Accessed 26/06/2023. [149] Edmund Optics. SCHOTT RG-630, 50mm Dia., 3mm Thick, Colored Glass Longpass Filter. Retrieved from https://www.edmundoptics.co.uk/p/rg-630-50mmdia- longpass-filter/20628/, Accessed 26/06/2023. [150] Stress Photonics Inc. https://glassphotonics.com/all-products/grey-fieldpolariscopes/, Accessed on 08/04/2020. [151] AMETEK Brookfield. Dial Reading Viscometer. Retrieved from https://www.brookfieldengineering.com/products/viscometers/laboratoryviscometers/ dial-reading-viscometer, Accessed 17/04/2023. [152] C. Kallendorf, D. Cyterski, A. Spinks, and D. Dreifus. D3359 - 87: Measuring Adhesion by Tape Test. In Radiation Curing Test Methods, pages 339 – 343. RadTech International, Cincinnati, 1988. [153] Tinius Olsen. Model 5ST: Electromechanical Testing Machine. Retrieved from https:// www.tiniusolsen.com/product/model-5st/, Accessed on 18/04/2023. [154] TA Instruments. DSC 25. https://www.tainstruments.com/dsc-25/, Accessed on 06/01/2019. [155] P. Gill, T. T. Moghadam, and B. Ranjbar. Differential scanning calorimetry techniques: applications in biology and nanoscience. Journal of biomolecular techniques : JBT, 21(4):167–193, 2010. [156] ThermoFisher Scientific. Nicolet™ iS™ 10 FTIR Spectrometer. Retrieved from https://www.thermofisher.com/order/catalog/product/IQLAADGAAGFAHDMAPC, Accessed 22/10/2021. [157] ASTM International. D523 - 14 Standard Test Method For Specular Gloss, 2018."],"dcterms:accessrights":["public"],"dc:title":["Development of Novel Coatings for Full Field Strain Measurements"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000154305617"]},"updated_at":"2026-11-18T23:25:06Z"}