{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:34606"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:34606","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Integrating sensors into total hip replacements","abstract":"Total hip replacement (THR) is a successful intervention for late stage osteoarthritis. The NJR reported in 2022, that 100,000 total hip replacement (THR) surgeries were performed in England, Wales and N.Ireland . Use of THR is increasing and younger patients are receiving THRs. Implants need to be reliable, have good survivorship, be cost effective and enable surgeons to provide a high level of patient care to reduce the growing burden on clinicians, healthcare providers and the economy. Instrumented implants capable of in-vivo sensing would allow for the continuous monitoring of patients post operatively. Data collected from the implant could provide insight into the function of the implant in-vivo and track the recovery of the patients. Previous work on integrating sensing systems into THRs has focused on measuring joint reaction forces and component loosening. Tracking joint kinematics would allow the collection of metrics such as joint range of motion and step count which are commonly used to track post operative recovery. Furthermore, measuring the components relative position and orientation could enable the detection of adverse events and so give early indications of component damage or the need for clinical intervention. The aim of this thesis was to develop a sensing system for use within a THR to measure the relative kinematics of the components. This thesis has resulted in a validated engineering prototype. With further development this sensing method could feature within an instrumented THR implant and be used to measure the kinematics of the components in vivo. Metrics such as joint range of motion, step count and risk of component impingement or impingement driven subluxation could be extracted and used to guide post operative care.","abstract_html":"Total hip replacement (THR) is a successful intervention for late stage osteoarthritis. The NJR reported in 2022, that 100,000 total hip replacement (THR) surgeries were performed in England, Wales and N.Ireland . Use of THR is increasing and younger patients are receiving THRs. Implants need to be reliable, have good survivorship, be cost effective and enable surgeons to provide a high level of patient care to reduce the growing burden on clinicians, healthcare providers and the economy. Instrumented implants capable of in-vivo sensing would allow for the continuous monitoring of patients post operatively. Data collected from the implant could provide insight into the function of the implant in-vivo and track the recovery of the patients. Previous work on integrating sensing systems into THRs has focused on measuring joint reaction forces and component loosening. Tracking joint kinematics would allow the collection of metrics such as joint range of motion and step count which are commonly used to track post operative recovery. Furthermore, measuring the components relative position and orientation could enable the detection of adverse events and so give early indications of component damage or the need for clinical intervention. The aim of this thesis was to develop a sensing system for use within a THR to measure the relative kinematics of the components. This thesis has resulted in a validated engineering prototype. With further development this sensing method could feature within an instrumented THR implant and be used to measure the kinematics of the components in vivo. Metrics such as joint range of motion, step count and risk of component impingement or impingement driven subluxation could be extracted and used to guide post operative care.","abstract_has_math":false,"creators":["Vickers, Oliver George"],"institution":"University of Leeds","degree_name":"Integrated Ph.D and Master","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Williams, Sophie","Culmer, Pete","Isaac, Graham","Kay, Robert","Board, Tim"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-09","date_published":"2023-09","updated_at":"2026-11-18T23:25:57Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/L014823/1","EP/R003971/1"],"render_values":[{"text":"EP/L014823/1","href":null,"code":true},{"text":"EP/R003971/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000206825148"],"render_values":[{"text":"0000-0002-0682-5148","href":"https://orcid.org/0000-0002-0682-5148","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/34606/1/Vickers_Thesis_Final_270323.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A34606","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Williams, Sophie","Culmer, Pete","Isaac, Graham","Kay, Robert","Board, Tim"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC"]},{"key":"dc:creator","label":"Author","values":["Vickers, Oliver George"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000206825148"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-09"]},{"key":"dc:date.issued","label":"Date","values":["2023-09"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Mechanical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/34606/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Abbott 2017. Press release: ABBOTT LAUNCHES THE FIRST AND ONLY SMARTPHONE COMPATIBLE INSERTABLE CARDIAC MONITOR IN THE U.S. [Accessed 15 June 2020]. Available from: abbott.mediaroom.com/. Abdulkarim, A., Ellanti, P., Motterlini, N., Fahey, T. and O’Byrne, J.M. 2013. Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trials. Orthopedic reviews. 5(1). Albert, J.A., Owolabi, V., Gebel, A., Brahms, C.M., Granacher, U. and Arnrich, B. 2020. Evaluation of the pose tracking performance of the azure kinect and kinect v2 for gait analysis in comparison with a gold standard: A pilot study. Sensors. 20(18), p.5104. Ali, M., Al-Hajjar, M., Jennings, L.M. and Fisher, J. 2017. Wear and deformation of metal-on-polyethylene hip replacements under edge loading conditions due to variations in surgical positioning In: Orthopaedic Proceedings. The British Editorial Society of Bone & Joint Surgery, p.12. Ali, M., Al-Hajjar, M., Partridge, S., Williams, S., Fisher, J. and Jennings, L.M. 2016. Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 230(5), pp.389–397. Almouahed, S., Gouriou, M., Hamitouche, C., Stindel, E. and Roux, C. 2011. The use of piezoceramics as electrical energy harvesters within instrumented knee implant during walking. IEEE/ASME Transactions on Mechatronics. 16(5), pp.799–807. Alshuhri, A.A., Holsgrove, T.P., Miles, A.W. and Cunningham, J.L. 2015. Development of a non-invasive diagnostic technique for acetabular component loosening in total hip replacements. Medical Engineering and Physics. 37(8), pp.739–745. Amar, A. Ben, Kouki, A.B. and Cao, H. 2015. Power approaches for implantable medical devices. sensors. 15(11), pp.28889–28914. Amstutz, H.C., Lodwig, R.M., Schurman, D.J. and Hodgson, A.G. 1975. Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus. Clinical orthopaedics and related research. (111), pp.124–130. AOA 2018. National Joint Replacement Registry: Hip, Knee & Shoulder Arthroplasty Annual Report 2018. Arami, A., Aminian, K., Forchelet, D. and Renaud, P. 2014. Implantable and wearable measurement system for smart knee prosthesis In: 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings. IEEE, pp.240–243. Arami, A., Simoncini, M., Atasoy, O., Ali, S., Hasenkamp, W., Bertsch, A., Meurville, E., Tanner, S., Renaud, P. and Dehollain, C. 2013. Instrumented knee prosthesis for force and kinematics measurements. IEEE transactions on automation science and engineering. 10(3), pp.615–624. Arami, A., Simoncini, M., Atasoy, O., Hasenkamp, W., Ali, S., Bertsch, A., Meurville, E., Tanner, S., Dejnabadi, H. and Leclercq, V. 2011. Instrumented prosthesis for knee implants monitoring In: 2011 IEEE international conference on automation science and engineering. IEEE, pp.828–835. Asif, Z. and Munir, M. 2005. Integrating the supply chain with RFID: A technical and business analysis. Communications of the Association for Information Systems. 15(1), p.24. Awal, M.R., Jusoh, M., Sabapathy, T., Kamarudin, M.R. and Rahim, R.A. 2016. State-of-the-art developments of acoustic energy transfer. International Journal of Antennas and Propagation. 2016. Balaban, A.L., Bakhvalov, Y.A. and Denisov, P.A. 2018. Review of methods for solving inverse problems in identifying permanent magnets of executive elements in dynamic devices In: MATEC Web of Conferences. EDP Sciences, p.4022. Baumann, A.P., O’Neill, C., Owens, M.C., Weber, S.C., Sivan, S., D’Amico, R., Carmody, S., Bini, S., Sawyer, A.J. and Lotz, J.C. 2020. FDA Public Workshop: Orthopaedic Sensing, Measuring, and Advanced Reporting Technology (SMART) Devices. Journal of orthopaedic research: official publication of the Orthopaedic Research Society. Bergmann, G, Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J. and Duda, G.N. 2001. Hip contact forces and gait patterns from routine activities. Journal of Biomechanics. 34(7), pp.859–871. Bergmann, G., Graichen, F., Dymke, J., Rohlmann, A., Duda, G.N. and Damm, P. 2012. High-tech hip implant for wireless temperature measurements in vivo. PLoS One. 7(8), p.e43489. Bergmann, G., Graichen, F., Jendrzynski, H. and Rohlmann, A. 1987. Long Term Animal Tests with Instrumented Hip Implants In: Biomechanics: Basic and Applied Research. Springer, pp.317–324. Bergmann, G., Graichen, F. and Rohlmann, A. 1993. Hip joint loading during walking and running, measured in two patients. Journal of biomechanics. 26(8), pp.969–990. Bergmann, G., Graichen, F., Rohlmann, A., Verdonschot, N. and van Lenthe, G.H. 2001. Frictional heating of total hip implants, Part 1: measurements in patients. Journal of Biomechanics. 34(4), pp.421–428. Bergmann, G., Graichen, F., Siraky, J., Jendrzynski, H. and Rohlmann, A. 1988. Multichannel strain gauge telemetry for orthopaedic implants. Journal of Biomechanics. 21(2), pp.169–176. Beshchasna, N., Uhlemann, J. and Wolter, K.-J. 2006. Researching of biochemical degradation of electronic materials in fluid electrolytic mediums In: 2006 29th International Spring Seminar on Electronics Technology. IEEE, pp.149–155. Bluetooth.com 2020. Learn about Bluetooth. [Accessed 15 June 2020]. Available from: bluetooth.com. Bock, D.C., Marschilok, A.C., Takeuchi, K.J. and Takeuchi, E.S. 2012. Batteries used to power implantable biomedical devices. Electrochimica acta. 84, pp.155–164. Bosker, B.H., Verheyen, C., Horstmann, W.G. and Tulp, N.J.A. 2007. Poor accuracy of freehand cup positioning during total hip arthroplasty. Archives of orthopaedic and trauma surgery. 127(5), pp.375–379. Bradley, P.D. 2011. Wireless medical implant technology—Recent advances and future developments In: 2011 Proceedings of the European Solid-State Device Research Conference (ESSDERC). IEEE, pp.54–58. British Heart Foundation 2020. Life with a pacemaker: Two inspiring stories. [Accessed 15 June 2020]. Available from: bhf.org.uk. Brown, T.D. and Callaghan, J.J. 2008. (ii) Impingement in total hip replacement: mechanisms and consequences. Current orthopaedics. 22(6), pp.376–391. Burns, A.J., Johnson, M.E. and Honeyman, P. 2016. A brief chronology of medical device security. Communications of the ACM. 59(10), pp.66–72. Camacho, J.M. and Sosa, V. 2013. Alternative method to calculate the magnetic field of permanent magnets with azimuthal symmetry. Revista mexicana de física E. 59(1), pp.8–17. Cao, H., Landge, V., Tata, U., Seo, Y.-S., Rao, S., Tang, S.-J., Tibbals, H.F., Spechler, S. and Chiao, J.-C. 2012. An implantable, batteryless, and wireless capsule with integrated impedance and pH sensors for gastroesophageal reflux monitoring. IEEE Transactions on Biomedical Engineering. 59(11), pp.3131–3139. Carlson, C.E., Mann, R.W. and Harris, W.H. 1974. A radio telemetry device for monitoring cartilage surface pressures in the human hip. IEEE Transactions on Biomedical Engineering. (4), pp.257–264. Çelik, T. and Kisioglu, Y. 2019. Determination of The Hip Stem Loosening Using Vibration Method. European Journal of Engineering and Natural Sciences. 3(1), pp.73–77. Cheney, D. 2013. CBS 60 Minute: Dick Cheney’s Heart. [Accessed 10 November 2020]. Available from: https://www.cbsnews.com/video/dick-cheneys-heart/. Chung, J.K., Pratt, G.W., Babyn, P.S. and Poss, R. 1979. NEW DIAGNOSTIC-TECHNIQUE FOR THE EVALUATION OF PROSTHETIC FIXATION In: IEEE Transactions on Biomedical Engineering. IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC 345 E 47TH ST, NEW YORK, NY …, p.532. CIHI 2018. Hip and Knee Replacements in Canada, 2016–2017: Canadian Joint Replacement Registry Annual Report. Ottawa, ON. Clearswift 2020. Infographic: Cybersecurity challenges in the UK healthcare sector. [Accessed 10 November 2020]. Available from: https://www.clearswift.com/blog/2020/01/22/infographic-cybersecurity-challenges-uk-healthcare-sector. Conaty-Buck, S. 2017. Cybersecurity and healthcare records. American Nurse Today. 12(9), pp.62–64. Cushner, F., Schiller, P., Gross, J., Mueller, J.K. and Hunter, W. 2021. A total knee arthroplasty prosthesis capable of remote patient monitoring In: Orthopaedic Proceedings. The British Editorial Society of Bone & Joint Surgery, p.18. Cushner, F.D., Schiller, P.J., Mueller, J.K.P., Gross, J.M. and Hunter, W.L. 2022. A cadaveric study addressing the feasibility of remote patient monitoring prosthesis for total knee arthroplasty. The Journal of Arthroplasty. 37(6), pp.S350–S354. Damm, P., Dymke, J., Ackermann, R., Bender, A., Graichen, F., Halder, A., Beier, A. and Bergmann, G. 2013. Friction in total hip joint prosthesis measured in vivo during walking. PloS one. 8(11). Damm, P., Graichen, F., Rohlmann, A., Bender, A. and Bergmann, G. 2010. Total hip joint prosthesis for in vivo measurement of forces and moments. Medical engineering & physics. 32(1), pp.95–100. Daou, H.E.L., Ng, K.C.G., Van Arkel, R., Jeffers, J.R.T. and y Baena, F.R. 2019. Robotic hip joint testing: Development and experimental protocols. Medical engineering & physics. 63, pp.57–62. Dargel, J., Oppermann, J., Brüggemann, G.-P. and Eysel, P. 2014. Dislocation following total hip replacement. Deutsches Ärzteblatt International. 111(51–52), p.884. Davies, J.P., Tse, M.-K. and Harris, W.H. 1996. Monitoring the integrity of the cement—metal interface of total joint components in vitro using acoustic emission and ultrasound. The Journal of arthroplasty. 11(5), pp.594–601. Davy, D.T., Kotzar, G.M., Brown, R.H., Heiple, K.G., Goldberg, V.M., Heiple, J.K.G., Berilla, J. and Burstein, A.H. 1988. Telemetric force measurements across the hip after total arthroplasty. The Journal of bone and joint surgery. American volume. 70(1), pp.45–50. Deyle, G. 2005. Diagnostic Imaging in Primary Care Physical Therapy. Primary Care for the Physical Therapist., pp.323-cp4. DHSC 2018. Securing cyber resilience in health and care: October 2018 update. Cyber Security Policy. DiGioia III, A.M., Jaramaz, B., Plakseychuk, A.Y., Moody Jr, J.E., Nikou, C., LaBarca, R.S., Levison, T.J. and Picard, F. 2002. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. The Journal of arthroplasty. 17(3), pp.359–364. Disilvestro, M.R., Sherman, J.T. and Dietz, T.L. 2007. In vivo joint space measurement device and method. Domas, S. 2019. Maybe Your Pacemaker Can’t Kill You. InSecurity [PODCAST]. Domas, S. 2016. Protecting Medical Devices from Cyberharm. Tedx Talks. [Online]. [Accessed 13 August 2020]. Available from: https://www.youtube.com/watch?v=EyqwUFJKZo0. Dorr, L.D., Wolf, A.W., Chandler, R. and Conaty, J.P. 1983. Classification and treatment of dislocations of total hip arthroplasty. Clinical orthopaedics and related research. (173), pp.151–158. English and Kilvington 1979. In vivo records of hip loads using a femoral implant with telemetric output (a prelimary report). Journal of biomedical engineering. 1(2), pp.111–115. Ermakova, A., Ribeiro, M., Spitzer, D. and Ortner, M. 2018. Analytical Development of a Four-Axis Magnetic Multimedia Control Element. IEEE Sensors Journal. 18(19), pp.7819–7825. Ewald, H., Ruther, C., Mittelmeier, W., Bader, R. and Kluess, D. 2011. A novel in vivo sensor for loosening diagnostics in total hip replacement In: SENSORS, 2011 IEEE. IEEE, pp.89–92. FCC 2017. Medical Device Radiocommunications Service. Available from: https://www.fcc.gov/medical-device-radiocommunications-service-medradio. FDA 2015a. Class 2 Device Recall Merlinhome RF Remote Monitoring Transmitter, Model EX1150, with software versions 6.1M or 7.0. FDA 2018a. Content of Premarket Submissions for Management of Cybersecurity in Medical Devices. FDA 2013. Cybersecurity for Medical Devices and Hospital Networks: FDA Safety Communication. [Accessed 10 November 2020]. Available from: http://wayback.archive-it.org/7993/20170722144747/https:/www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm356423.htm. FDA 2018b. Cybersecurity Updates Affecting Medtronic Implantable Cardiac Device Programmers: FDA Safety Communication. [Accessed 10 November 2020]. Available from: https://www.fda.gov/medical-devices/safety-communications/cybersecurity-updates-affecting-medtronic-implantable-cardiac-device-programmers-fda-safety. FDA 2015b. Cybersecurity Vulnerabilities of Hospira Symbiq Infusion System: FDA Safety Communication. [Accessed 10 November 2020]. Available from: https://web.archive.org/web/20170111070001/http:/www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm456815.htm. FDA 2014. GUIDANCE DOCUMENT Content of Premarket Submissions for Management of Cybersecurity in Medical Devices. [Accessed 10 November 2020]. Available from: https://www.fda.gov/regulatory-information/search-fda-guidance-documents/content-premarket-submissions-management-cybersecurity-medical-devices-0. FDA 2018c. Medtronic Recalls Remote Controllers for MiniMed Insulin Pumps for Potential Cybersecurity Risks. FDA 2020. SweynTooth Cybersecurity Vulnerabilities May Affect Certain Medical Devices: FDA Safety Communication. FDA 2019. URGENT/11 Cybersecurity Vulnerabilities in a Widely-Used Third-Party Software Component May Introduce Risks During Use of Certain Medical Devices: FDA Safety Communication. [Accessed 10 November 2020]. Available from: https://www.fda.gov/medical-devices/safety-communications/urgent11-cybersecurity-vulnerabilities-widely-used-third-party-software-component-may-introduce. Gabriel, S., Lau, R.W. and Gabriel, C. 1996. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Physics in medicine & biology. 41(11), p.2271. Geerdink, C.H., Grimm, B., Vencken, W., Heyligers, I.C. and Tonino, A.J. 2008. The determination of linear and angular penetration of the femoral head into the acetabular component as an assessment of wear in total hip replacement: a comparison of four computer-assisted methods. The Journal of Bone and Joint Surgery. British volume. 90(7), pp.839–846. Georgiou, A.P. and Cunningham, J.L. 2001. Accurate diagnosis of hip prosthesis loosening using a vibrational technique. Clinical Biomechanics. 16(4), pp.315–323. Ghaffari, M., Nickmanesh, R., Tamannaee, N. and Farahmand, F. 2012. The impingement-dislocation risk of total hip replacement: Effects of cup orientation and patient maneuvers In: 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE, pp.6801–6804. Ghorbani, S., Mahdaviani, K., Thaler, A., Kording, K., Cook, D.J., Blohm, G. and Troje, N.F. 2021. MoVi: A large multi-purpose human motion and video dataset. Plos one. 16(6), p.e0253157. Girase, H., Nyayapati, P., Booker, J., Lotz, J.C., Bailey, J.F. and Matthew, R.P. 2021. Automated assessment and classification of spine, hip, and knee pathologies from sit-to-stand movements collected in clinical practice. Journal of Biomechanics. 128, p.110786. Goodin, D. 2011. Insulin pump hack delivers fatal dosage over the air. theregister. [Online]. [Accessed 10 November 2020]. Available from: https://www.theregister.com/2011/10/27/fatal_insulin_pump_attack/. Graichen, F. and Bergmann, G. 1991. Four-channel telemetry system for in vivo measurement of hip joint forces. Journal of biomedical engineering. 13(5), pp.370–374. Graichen, F., Bergmann, G. and Rohlmann, A. 1999. Hip endoprosthesis for in vivo measurement of joint force and temperature. Journal of biomechanics. 32(10), pp.1113–1117. Gray, P. 2012. Pacemakers, defibrillators open to attack. theregister. [Online]. [Accessed 10 November 2020]. Available from: https://www.theregister.com/2012/10/17/pacemakers_open_to_wireless_attack/. Grillini, L. and Affatato, S. 2013. How to measure wear following total hip arthroplasty. Hip International. 23(3), pp.233–242. Guevara-Valdivia, M.E. and Torres, P.I. 2011. Remote Monitoring of Implantable Pacemaker, Cardioverter Defibrillator, and Cardiac Resynchronizer, Modern Pacemakers - Present and Future, Prof. Mithilesh R Das. Hadley, M., Hardaker, C., Isaac, G. and Fisher, J. 2018. Wear of different materials for total hip replacement under adverse stop-dwell-start in vitro wear simulation conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 232(12), pp.1261–1270. Halperin, D., Heydt-Benjamin, T.S., Ransford, B., Clark, S.S., Defend, B., Morgan, W., Fu, K., Kohno, T. and Maisel, W.H. 2008. Pacemakers and implantable cardiac defibrillators: Software radio attacks and zero-power defenses In: 2008 IEEE Symposium on Security and Privacy (sp 2008). IEEE, pp.129–142. Hammerberg, E.M., Wan, Z., Dastane, M. and Dorr, L.D. 2010. Wear and Range of Motion of Different Femoral Head Sizes. The Journal of Arthroplasty. 25(6), pp.839–843. Hassan, D.M., Johnston, G.H.F., Dust, W.N.C., Watson, G. and Dolovich, A.T. 1998. Accuracy of intraoperative assessment of acetabular prosthesis placement. The Journal of Arthroplasty. 13(1), pp.80–84. Henderson, D.M. 1977. Euler angles, quaternions, and transformation matrices for space shuttle analysis. Herrmann, S., Kaehler, M., Grawe, R., Kluess, D., Woernle, C. and Bader, R. 2015. Physiological-like testing of the dislocation stability of artificial hip joints In: New Trends in Mechanism and Machine Science: From Fundamentals to Industrial Applications. Springer, pp.659–667. Islam, M.N. and Yuce, M.R. 2016. Review of Medical Implant Communication System (MICS) band and network. ICT Express. 2(4), pp.188–194. Jantara, V.L. 2020. Wind turbine gearboxes: Failures, surface treatments and condition monitoring. Non-Destructive Testing and Condition Monitoring Techniques for Renewable Energy Industrial Assets., pp.69–90. Jaramaz, B., Nikou, C., Simon, D.A. and DiGioia, A.M. 1997. Range of motion after total hip arthroplasty: Experimental verification of the analytical simulator In: CVRMed-MRCAS’97. Springer, pp.573–582. Jones, D., Wang, L., Ghanbari, A., Vardakastani, V., Kedgley, A.E., Gardiner, M.D., Vincent, T.L., Culmer, P.R. and Alazmani, A. 2020. Design and evaluation of magnetic Hall effect tactile sensors for use in sensorized splints. Sensors. 20(4), p.1123. Joung, Y.-H. 2013. Development of implantable medical devices: from an engineering perspective. International neurourology journal. 17(3), p.98. Kebbach, M., Grawe, R., Geier, A., Winter, E., Bergschmidt, P., Kluess, D., D’Lima, D., Woernle, C. and Bader, R. 2019. Effect of surgical parameters on the biomechanical behaviour of bicondylar total knee endoprostheses–A robot-assisted test method based on a musculoskeletal model. Scientific reports. 9(1), p.14504. Kelmers, E., Szuba, A., King, S.W., Palan, J., Freear, S., Pandit, H.G. and van Duren, B.H. 2022. Smart Knee Implants: An Overview of Current Technologies and Future Possibilities. Indian Journal of Orthopaedics., pp.1–8. Kennedy, J.G., Rogers, W.B., Soffe, K.E., Sullivan, R.J., Griffen, D.G. and Sheehan, L.J. 1998. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. The Journal of arthroplasty. 13(5), pp.530–534. Khan, W. and Badii, A. 2019. Pathological gait abnormality detection and segmentation by processing the hip joints motion data to support mobile gait rehabilitation. Research in C Medical & Engineering Sciences. 7(03). Khokle, R., Esselle, K. and Bokor, D. 2018. Design, Modeling, and Evaluation of the Eddy Current Sensor Deeply Implanted in the Human Body. Sensors. 18(11), p.3888. Kilvington, M. and Goodman, R.M.F. 1981. In vivo hip joint forces recorded on a strain gauged ‘English’prosthesis using an implanted transmitter. Engineering in Medicine. 10(4), pp.175–187. Kim, J.T. and Yoo, J.J. 2016. Implant design in cementless hip arthroplasty. Hip & pelvis. 28(2), pp.65–75. Kiourti, A., Costa, J.R., Fernandes, C.A. and Nikita, K.S. 2014. A broadband implantable and a dual-band on-body repeater antenna: Design and transmission performance. IEEE transactions on antennas and propagation. 62(6), pp.2899–2908. Kirsten, S., Uhlemann, J., Braunschweig, M. and Wolter, K.J. 2012. Packaging of electronic devices for long-term implantation In: 2012 35th International Spring Seminar on Electronics Technology. IEEE, pp.123–127. Knight, S.R., Aujla, R. and Biswas, S.P. 2011. Total Hip Arthroplasty-over 100 years of operative history. Orthopedic reviews. 3(2). Komistek, R.D., Dennis, D.A., Ochoa, J.A., Haas, B.D. and Hammill, C. 2002. In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty. JBJS. 84(10), pp.1836–1841. Kotzar, G.M., Davy, D.T., Goldberg, V.M., Heiple, K.G., Berilla, J., Heiple Jr, K.G., Brown, R.H. and Burstein, A.H. 1991. Telemeterized in vivo hip joint force data: a report on two patients after total hip surgery. Journal of Orthopaedic Research. 9(5), pp.621–633. Lachiewicz, P.F., Soileau, E.S. and Martell, J.M. 2016. Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 years: the effect of femoral head size. Clinical Orthopaedics and Related Research®. 474(2), pp.365–371. Lange, H.-E., Hohlfeld, D., Bader, R. and Kluess, D. 2020. A piezoelectric energy harvesting concept for an energy-autonomous instrumented total hip replacement. Smart Materials and Structures. Learmonth, I.D., Young, C. and Rorabeck, C. 2007. The operation of the century: total hip replacement. The Lancet. 370(9597), pp.1508–1519. Ledet, E.H., Liddle, B., Kradinova, K. and Harper, S. 2018. Smart implants in orthopedic surgery, improving patient outcomes: a review. Innovation and entrepreneurship in health. 5, p.41. Lewinnek, G.E., Lewis, J.L., Tarr, R., Compere, C.L. and Zimmerman, J.R. 1978. Incidence of dislocation following hip arthroplasty for patients in the rehabilitation setting. J Bone Joint Surg Am. 60(2), pp.217–220. Li, P.L.S., Jones, N.B. and Gregg, P.J. 1996. Vibration analysis in the detection of total hip prosthetic loosening. Medical engineering & physics. 18(7), pp.596–600. Liu, Q., Cheng, X., Yan, D. and Zhou, Y. 2019. Plain radiography findings to predict dislocation after total hip arthroplasty. Journal of Orthopaedic Translation. Lombardi Jr, A. V, Mallory, T.H., Dennis, D.A., Komistek, R.D., Fada, R.A. and Northcut, E.J. 2000. An in vivo determination of total hip arthroplasty pistoning during activity. The Journal of Arthroplasty. 15(6), pp.702–709. Lumetti, S., Malagò, P., Spitzer, D., Zaruba, S. and Ortner, M. 2020. Computationally Efficient Magnetic Position System Calibration In: Engineering Proceedings. Multidisciplinary Digital Publishing Institute, p.72. Luo, Y., Coppola, S.M., Dixon, P.C., Li, S., Dennerlein, J.T. and Hu, B. 2020. A database of human gait performance on irregular and uneven surfaces collected by wearable sensors. Scientific data. 7(1), p.219. Lutz., C. and Foletto., A. 2019. Joystick with Allegro Position Sensor IC. Maag, C., Metcalfe, A., Cracaoanu, I., Wise, C. and Auger, D.D. 2021. The development of simulator testing for total knee replacements. Biosurface and Biotribology. 7(2), pp.70–82. Maggs, J. and Wilson, M. 2017. The relative merits of cemented and uncemented prostheses in total hip arthroplasty. Indian journal of orthopaedics. 51(4), p.377. Malagò, P., Slanovc, F., Herzog, S., Lumetti, S., Schaden, T., Pellegrinetti, A., Moridi, M., Abert, C., Suess, D. and Ortner, M. 2020. Magnetic Position System Design Method Applied to Three-Axis Joystick Motion Tracking. Sensors. 20(23), p.6873. Malik, A., Maheshwari, A. and Dorr, L.D. 2007. Impingement with total hip replacement. JBJS. 89(8), pp.1832–1842. Maneewongvatana, S. and Mount, D.M. 1999. Analysis of approximate nearest neighbor searching with clustered point sets. arXiv preprint cs/9901013. Marchetti, E., Krantz, N., Berton, C., Bocquet, D., Fouilleron, N., Migaud, H. and Girard, J. 2011. Component impingement in total hip arthroplasty: frequency and risk factors. A continuous retrieval analysis series of 416 cup. Orthopaedics & Traumatology: Surgery & Research. 97(2), pp.127–133. Marschner, U., Grätz, H., Jettkant, B., Ruwisch, D., Woldt, G., Fischer, W.-J. and Clasbrummel, B. 2009. Integration of a wireless lock-in measurement of hip prosthesis vibrations for loosening detection. Sensors and Actuators A: Physical. 156(1), pp.145–154. Matharu, G.S., Culliford, D.J., Blom, A.W. and Judge, A. 2022. Projections for primary hip and knee replacement surgery up to the year 2060: an analysis based on data from The National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. The Annals of The Royal College of Surgeons of England. 104(6), pp.443–448. Mathworks 2021. Levenberg-Marquardt backpropagation. Available from: https://uk.mathworks.com/help/deeplearning/ref/trainlm.html. MathWorks 2019. magcal. [Accessed 27 February 2024]. Available from: https://uk.mathworks.com/help/nav/ref/magcal.html. Mavrogordato, M., Taylor, M., Taylor, A. and Browne, M. 2011. Real time monitoring of progressive damage during loading of a simplified total hip stem construct using embedded acoustic emission sensors. Medical engineering & physics. 33(4), pp.395–406. McCalden, R.W., Naudie, D.D., Yuan, X. and Bourne, R.B. 2005. Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. JBJS. 87(10), pp.2323–2334. McKellop, H.A. 2007. The lexicon of polyethylene wear in artificial joints. Biomaterials. 28(34), pp.5049–5057. McKellop, H.A. and D’Lima, D. 2008. How have wear testing and joint simulator studies helped to discriminate among materials and designs? JAAOS-Journal of the American Academy of Orthopaedic Surgeons. 16, pp.S111–S119. MDCG 2019. MDCG 2019-16 - Guidance on Cybersecurity for medical devices. Melexis 2021. How to use a magnetometer in a position sensor application. Melia, G. 2013. Electromagnetic absorption by the human body from 1-15 GHz. (Doctoral Dissertation, University of York). Mentiplay, B.F., Banky, M., Clark, R.A., Kahn, M.B. and Williams, G. 2018. Lower limb angular velocity during walking at various speeds. Gait & posture. 65, pp.190–196. Mohammadbagherpoor, H., Ierymenko, P., Craver, M.H., Carlson, J., Dausch, D., Grant, E. and Lucey, J.D. 2019. An Implantable Wireless Inductive Sensor System Designed To Monitor Prosthesis Motion in Total Joint Replacement Surgery. IEEE Transactions on Biomedical Engineering. Muro-De-La-Herran, A., Garcia-Zapirain, B. and Mendez-Zorrilla, A. 2014. Gait analysis methods: An overview of wearable and non-wearable systems, highlighting clinical applications. Sensors. 14(2), pp.3362–3394. Murray, D.W. 1992. Impingement and loosening of the long posterior wall acetabular implant. The Journal of bone and joint surgery. British volume. 74(3), pp.377–379. Murray, D.W. 1993. The definition and measurement of acetabular orientation. The Journal of bone and joint surgery. British volume. 75(2), pp.228–232. Nagymáté, G. and Kiss, R.M. 2018. Application of OptiTrack motion capture systems in human movement analysis: A systematic literature review. Recent Innovations in Mechatronics. 5(1.), pp.1–9. National Joint Registry 2020. 17th Annual Report 2020. [Accessed 13 November 2020]. Available from: https://reports.njrcentre.org.uk/Portals/0/PDFdownloads/NJR 17th Annual Report 2020.pdf. Nelson, B.D., Karipott, S.S., Wang, Y. and Ong, K.G. 2020. Wireless Technologies for Implantable Devices. Sensors. 20(16), p.4604. NHS 2023. Osteoarthritis. Available from: https://www.nhs.uk/conditions/osteoarthritis/. NJR 2018. NJR 15th Annual Report 2018. NJR 2022. NJR Report 2022. Available from: https://www.njrcentre.org.uk/. NOAA - NCEI 2024. Geomagnetism Frequently Asked Questions. Available from: www.ncei.noaa.gov/. O’Dwyer Lancaster‐Jones, O., Williams, S., Jennings, L.M., Thompson, J., Isaac, G.H., Fisher, J. and Al‐Hajjar, M. 2018. An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 106(5), pp.1897–1906. OptiTrack 2023. OptiTrack for Movement Sciences. Available from: optitrack.com. Orthload 2019. Loading of Orthopaedic Implants. [Accessed 30 January 2020]. Available from: https://orthoload.com/. Orthopaedic Design & Technology 2021. First Knee Replacement Surgery with Persona IQ Smart Knee. [Accessed 2 June 2023]. Available from: https://www.odtmag.com/contents/view_breaking-news/2021-10-13/first-knee-replacement-surgery-with-persona-iq-smart-knee/. Ortho-tag 2020. Ortho-tag. [Accessed 18 November 2020]. Available from: www.orthotag.com/. Ortner, M., Ribeiro, M. and Spitzer, D. 2018. Absolute long-range linear position system with a single 3-D magnetic field sensor. IEEE Transactions on Magnetics. 55(1), pp.1–4. Otake, Y., Suzuki, N., Hattori, A., Hayashibe, M., Miki, H., Yamamura, M., Sugano, N., Yonenobu, K. and Ochi, T. 2005. Soft-Tissue Balance Evaluation System for Total Hip Arthroplasty by Intraoperative Contact Pressure Measurement at the Hip Joint. Studies in health technology and informatics. 119, p.416. Ozeri, S. and Shmilovitz, D. 2010. Ultrasonic transcutaneous energy transfer for powering implanted devices. Ultrasonics. 50(6), pp.556–566. Ozyagcilar, T. 2012. Calibrating an ecompass in the presence of hard and soft-iron interference. Freescale Semiconductor Ltd., pp.1–17. Padgett, D.E. and Warashina, H. 2004. The unstable total hip replacement. Clinical Orthopaedics and Related Research®. 420, pp.72–79. Pancharoen, K., Zhu, D. and Beeby, S.P. 2014. A hip implant energy harvester In: Journal of Physics: Conference Series. IOP Publishing, p.12038. Panero, E., Digo, E., Agostini, V. and Gastaldi, L. 2018. Comparison of different motion capture setups for gait analysis: Validation of spatio-temporal parameters estimation In: 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA). IEEE, pp.1–6. Parvizi, J., Kim, G.K., Parvizi, J. and Kim, G.K. 2010. Bone Scan. High Yield Orthopaedics., pp.66–67. Pounds, G. 2023. Development of a Novel Motion-Capture Methodology to Assess Medial Meniscus Displacement during Cadaveric Gait Simulation [IN PRINT]. University of Leeds. Pryce, G., Al-Hajjar, M., Thompson, J., Wilcox, R., Board, T. and Williams, S. 2021. AN IN VITRO METHOD TO INVESTIGATE IMPLANT IMPINGEMENT OF HIP ARTHROPLASTIES In: Orthopaedic Proceedings. The British Editorial Society of Bone & Joint Surgery, p.21. Pryce, G.M. 2019. PhD: Polyethylene acetabular liner rim damage in total hip replacements. University of Leeds, White Rose eTheses Online. Pryce, G.M., Sabu, B., Al-Hajjar, M., Wilcox, R.K., Thompson, J., Isaac, G.H., Board, T. and Williams, S. 2022. Impingement in total hip arthroplasty: A geometric model. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 236(4), pp.504–514. Puers, R., Catrysse, M., Vandevoorde, G., Collier, R.J., Louridas, E., Burny, F., Donkerwolcke, M. and Moulart, F. 2000. A telemetry system for the detection of hip prosthesis loosening by vibration analysis. Sensors and Actuators A: Physical. 85(1–3), pp.42–47. Rieger, J.S., Jaeger, S., Schuld, C., Kretzer, J.P. and Bitsch, R.G. 2013. A vibrational technique for diagnosing loosened total hip endoprostheses: An experimental sawbone study. Medical engineering & physics. 35(3), pp.329–337. Rittmeister, M. and Callitsis, C. 2006. Factors influencing cup orientation in 500 consecutive total hip replacements. Clinical Orthopaedics and Related Research®. 445, pp.192–196. Roithmayr, C.M., Hodges, D.H. and Cross, P. 2016. Dynamics: Theory and Application of Kane’s Method [Online]. Cambridge University Press. Available from: https://books.google.co.uk/books?id=dKizCwAAQBAJ. Roques, A., Browne, M., Thompson, J., Rowland, C. and Taylor, A. 2004. Investigation of fatigue crack growth in acrylic bone cement using the acoustic emission technique. Biomaterials. 25(5), pp.769–778. Rosenstein, A.D., McCoy, G.F., Bulstrode, C.J., McLardy-Smith, P.D., Cunningham, J.L. and Turner-Smith, A.R. 1989. The differentiation of loose and secure femoral implants in total hip replacement using a vibrational technique: an anatomical and pilot clinical study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 203(2), pp.77–81. Rowland, C., Browne, M., Taylor, A. and Leatherhead, U.K. 2004. Dynamic health monitoring of metal on metal hip prostheses using acoustic emission In: 26th European conference on acoustic emission testing. Citeseer, pp.465–467. Rowlands, A., Duck, F.A. and Cunningham, J.L. 2008. Bone vibration measurement using ultrasound: Application to detection of hip prosthesis loosening. Medical engineering & physics. 30(3), pp.278–284. Ruther, C., Ewald, H., Mittelmeier, W., Bader, R. and Kluess, D. 2010. Localization of uncemented hip Stem loosening with a novel in-vivo sensor system based on vibration analysis In: 6th World Congress of Biomechanics (WCB 2010). August 1-6, 2010 Singapore. Springer, pp.620–623. Ruther, C., Gabler, C., Ewald, H., Ellenrieder, M., Haenle, M., Lindner, T., Mittelmeier, W., Bader, R. and Kluess, D. 2014. In vivo monitoring of implant osseointegration in a rabbit model using acoustic sound analysis. Journal of Orthopaedic Research. 32(4), pp.606–612. Ruther, C., Timm, U., Ewald, H., Mittelmeier, W., Bader, R., Schmelter, R., Lohrengel, A. and Kluess, D. 2012. Current possibilities for detection of loosening of total hip replacements and how intelligent implants could improve diagnostic accuracy In: Recent advances in arthroplasty. IntechOpen. Rychlik, M., Wendland, G., Jackowski, M., Rennert, R., Schaser, K.-D. and Nowotny, J. 2023. Calibration procedure and biomechanical validation of an universal six degree-of-freedom robotic system for hip joint testing. Journal of Orthopaedic Surgery and Research. 18(1), p.164. Rydell, N.W. 1966. Forces acting on the femoral head-prosthesis: a study on strain gauge supplied prostheses in living persons. Acta Orthopaedica Scandinavica. 37(sup88), pp.1–132. Sample, A.P., Yeager, D.J., Powledge, P.S., Mamishev, A. V and Smith, J.R. 2008. Design of an RFID-based battery-free programmable sensing platform. IEEE transactions on instrumentation and measurement. 57(11), pp.2608–2615. Sauer, S., Kirsten, S., Storck, F., Grätz, H., Marschner, U., Ruwisch, D. and Fischer, W.-J. 2013. A medical wireless measurement system for hip prosthesis loosening detection based on vibration analysis. Sensors & Transducers. 18(1), p.134. Scifert, C.F., Brown, T.D. and Lipman, J.D. 1999. Finite element analysis of a novel design approach to resisting total hip dislocation. Clinical Biomechanics. 14(10), pp.697–703. Sejdić, E., Rothfuss, M.A., Stachel, J.R., Franconi, N.G., Bocan, K., Lovell, M.R. and Mickle, M.H. 2013. Innovation and translation efforts in wireless medical connectivity, telemedicine and eMedicine: a story from the RFID Center of Excellence at the University of Pittsburgh. Annals of biomedical engineering. 41(9), pp.1913–1925. Semlitsch, M. and Willert, H.G. 1997. Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 211(1), pp.73–88. Shadid, R. and Noghanian, S. 2018. A literature survey on wireless power transfer for biomedical devices. International Journal of Antennas and Propagation. 2018. SHAR 2017. Swedish Hip Arthroplasty Register Annual Report 2017. Shon, W.Y., Baldini, T., Peterson, M.G., Wright, T.M. and Salvati, E.A. 2005. Impingement in total hip arthroplasty: a study of retrieved acetabular components. The Journal of arthroplasty. 20(4), pp.427–435. Siciliano, B., Khatib, O. and Kröger, T. 2008. Springer handbook of robotics. Springer. Silva, N.M., Santos, P.M., Ferreira, J.A.F., dos Santos, M.P.S., Ramos, A., Simões, J.A.O., Reis, M. and Morais, R. 2013. Power management architecture for smart hip prostheses comprising multiple energy harvesting systems. Sensors and Actuators A: physical. 202, pp.183–192. Singh, J.A., Yu, S., Chen, L. and Cleveland, J.D. 2019. Rates of total joint replacement in the United States: future projections to 2020–2040 using the national inpatient sample. The Journal of rheumatology. 46(9), pp.1134–1140. Soares dos Santos, M.P., Ferreira, J.A.F., Ramos, A., Simões, J.A.O., Morais, R., Silva, N.M., Santos, P.M., Reis, M.C. and Oliveira, T. 2014. Instrumented hip joint replacements, femoral replacements and femoral fracture stabilizers. Expert review of medical devices. 11(6), pp.617–635. Soares dos Santos, M.P., Ferreira, J.A.F., Ramos, A., Simões, J.A.O., Morais, R., Silva, N.M., Santos, P.M., Reis, M.J.C.S. and Oliveira, T. 2013. Instrumented hip implants: Electric supply systems. Journal of Biomechanics. 46(15), pp.2561–2571. Southampton, U.H. 2018. Press release: Doctors implant and programme pacemaker using Bluetooth technology. [Accessed 15 June 2020]. Available from: uhs.nhs.uk/. Souto, G., Muralter, F., Arjona, L., Landaluce, H. and Perallos, A. 2019. Protocol for Streaming Data from an RFID Sensor Network. Sensors. 19(14), p.3148. Stryker 2023. MotionSense with OrthoLogIQ. Where innovation meets recovery. Sugiyama, H., Whiteside, L.A. and Kaiser, A.D. 1989. Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission. Clinical orthopaedics and related research. (249), pp.122–128. Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P. and Gretzer, C. 2006. Aseptic loosening, not only a question of wear: a review of different theories. Acta orthopaedica. 77(2), pp.177–197. Teeter, M., Lam, K., Howard, J., Lanting, B. and Yuan, X. 2016. RADIOSTEREOMETRIC ANALYSIS USING CLINICAL RADIOGRAPHIC VIEWS: MEASURING TOTAL HIP CUP POSITION AND WEAR In: Orthopaedic Proceedings. The British Editorial Society of Bone & Joint Surgery, p.5. Temmerman, O.P.P., Raijmakers, P., Berkhof, J., Hoekstra, O.S., Teule, G.J.J. and Heyligers, I.C. 2005. Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis. The Journal of bone and joint surgery. British volume. 87(6), pp.781–785. Teshome, A.K., Kibret, B. and Lai, D.T.H. 2018. A review of implant communication technology in WBAN: Progress and challenges. IEEE reviews in biomedical engineering. 12, pp.88–99. Tesla, N. 1900. System of transmission of electrical energy. TracPatch Health 2021. TracPatch. Turley, G.A., Ahmed, S.M.Y., Williams, M.A. and Griffin, D.R. 2011. Establishing a range of motion boundary for total hip arthroplasty. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 225(8), pp.769–782. Uhlemann, J., Schindler, S., Schlottig, G., Drechsler, M., Starcke, S., Vollmer, G. and Wolter, K.-J. 2005. Cytotoxicity of COB materials In: Proceedings Electronic Components and Technology, 2005. ECTC’05. IEEE, pp.593–596. Usrey, M.M., Noble, P.C., Rudner, L.J., Conditt, M.A., Birman, M. V, Santore, R.F. and Mathis, K.B. 2006. Does neck/liner impingement increase wear of ultrahigh-molecular-weight polyethylene liners? The Journal of arthroplasty. 21(6), pp.65–71. Varga, M. and Wolter, K.-J. 2014. Sensors and imaging methods for detecting loosening of orthopedic implants—a review In: 2014 IEEE 20th International Symposium for Design and Technology in Electronic Packaging (SIITME). IEEE, pp.333–335. Vena, A., Sorli, B., Charlot, B. and Naudi, S. 2015. An RFID-based implant for identification and pressure sensing of orthopedic prosthesis In: 2015 1st URSI Atlantic Radio Science Conference (URSI AT-RASC). IEEE, p.1. Vickers, O.G., Culmer, P.R., Isaac, G.H., Kay, R.W., Shuttleworth, M.P., Board, T. and Williams, S. 2021. Is in vivo sensing in a total hip replacement a possibility? A review on past systems and future challenges. Progress in Biomedical Engineering. 3(4), p.42004. Virtanen, P., Gommers, R., Oliphant, T.E., Haberland, M., Reddy, T., Cournapeau, D., Burovski, E., Peterson, P., Weckesser, W. and Bright, J. 2020. SciPy 1.0: fundamental algorithms for scientific computing in Python. Nature methods. 17(3), pp.261–272. Wageningen, D. van and Waffenschmidt, E. 2018. Basic principle of inductive power transmission. [Accessed 14 June 2020]. Available from: http://www.wirelesspowerconsortium.com/. Wevers and Surgeon 2000. Acoustic Emission and Composites. Comprehensive Composite Materials., pp.345–357. WHO 1993. Electromagnetic fields (300 Hz to 300 GHz / published under the joint sponsorship of the United Nations Environment Programme, the International Radiation Protection Association, and the World Health Organization. World Health Organization. Williams, S., Butterfield, M., Stewart, T., Ingham, E., Stone, M. and Fisher, J. 2003. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 217(2), pp.147–153. Williams, S.P. 2022. PhD: Impingement in total hip replacements. University of Leeds, White Rose eTheses Online. Wooley, P.H. and Schwarz, E.M. 2004. Aseptic loosening. Gene therapy. 11(4), p.402. Xiao, Z., Tan, X., Chen, X., Chen, S., Zhang, Z., Zhang, H., Wang, J., Huang, Y., Zhang, P. and Zheng, L. 2015. An implantable RFID sensor tag toward continuous glucose monitoring. IEEE journal of biomedical and health informatics. 19(3), pp.910–919. Yao, M. 2017. Your Electronic Medical Records Could Be Worth $1000 To Hackers. Forbes. [Online]. [Accessed 9 November 2020]. Available from: www.forbes.com/. Zimmer Biomet 2023. Persona IQ, The Smart Knee."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Integrated Ph.D and Master"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/L014823/1","EP/R003971/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/34606/1/Vickers_Thesis_Final_270323.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Total hip replacement (THR) is a successful intervention for late stage osteoarthritis. The NJR reported in 2022, that 100,000 total hip replacement (THR) surgeries were performed in England, Wales and N.Ireland . Use of THR is increasing and younger patients are receiving THRs. Implants need to be reliable, have good survivorship, be cost effective and enable surgeons to provide a high level of patient care to reduce the growing burden on clinicians, healthcare providers and the economy. Instrumented implants capable of in-vivo sensing would allow for the continuous monitoring of patients post operatively. Data collected from the implant could provide insight into the function of the implant in-vivo and track the recovery of the patients. Previous work on integrating sensing systems into THRs has focused on measuring joint reaction forces and component loosening. Tracking joint kinematics would allow the collection of metrics such as joint range of motion and step count which are commonly used to track post operative recovery. Furthermore, measuring the components relative position and orientation could enable the detection of adverse events and so give early indications of component damage or the need for clinical intervention. The aim of this thesis was to develop a sensing system for use within a THR to measure the relative kinematics of the components. This thesis has resulted in a validated engineering prototype. With further development this sensing method could feature within an instrumented THR implant and be used to measure the kinematics of the components in vivo. Metrics such as joint range of motion, step count and risk of component impingement or impingement driven subluxation could be extracted and used to guide post operative care."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Integrating sensors into total hip replacements"]}]}],"canonical_facts":{"dc:contributor.advisor":["Williams, Sophie","Culmer, Pete","Isaac, Graham","Kay, Robert","Board, Tim"],"dc:contributor.sponsor":["EPSRC"],"dc:creator":["Vickers, Oliver George"],"dc:date":["2023-09"],"dc:date.issued":["2023-09"],"dc:description.abstract":["Total hip replacement (THR) is a successful intervention for late stage osteoarthritis. The NJR reported in 2022, that 100,000 total hip replacement (THR) surgeries were performed in England, Wales and N.Ireland . Use of THR is increasing and younger patients are receiving THRs. Implants need to be reliable, have good survivorship, be cost effective and enable surgeons to provide a high level of patient care to reduce the growing burden on clinicians, healthcare providers and the economy. Instrumented implants capable of in-vivo sensing would allow for the continuous monitoring of patients post operatively. Data collected from the implant could provide insight into the function of the implant in-vivo and track the recovery of the patients. Previous work on integrating sensing systems into THRs has focused on measuring joint reaction forces and component loosening. Tracking joint kinematics would allow the collection of metrics such as joint range of motion and step count which are commonly used to track post operative recovery. Furthermore, measuring the components relative position and orientation could enable the detection of adverse events and so give early indications of component damage or the need for clinical intervention. The aim of this thesis was to develop a sensing system for use within a THR to measure the relative kinematics of the components. This thesis has resulted in a validated engineering prototype. With further development this sensing method could feature within an instrumented THR implant and be used to measure the kinematics of the components in vivo. Metrics such as joint range of motion, step count and risk of component impingement or impingement driven subluxation could be extracted and used to guide post operative care."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/L014823/1","EP/R003971/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/34606/1/Vickers_Thesis_Final_270323.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Mechanical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/34606/"],"dc:relation.references":["Abbott 2017. Press release: ABBOTT LAUNCHES THE FIRST AND ONLY SMARTPHONE COMPATIBLE INSERTABLE CARDIAC MONITOR IN THE U.S. [Accessed 15 June 2020]. Available from: abbott.mediaroom.com/. Abdulkarim, A., Ellanti, P., Motterlini, N., Fahey, T. and O’Byrne, J.M. 2013. Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trials. Orthopedic reviews. 5(1). Albert, J.A., Owolabi, V., Gebel, A., Brahms, C.M., Granacher, U. and Arnrich, B. 2020. Evaluation of the pose tracking performance of the azure kinect and kinect v2 for gait analysis in comparison with a gold standard: A pilot study. Sensors. 20(18), p.5104. Ali, M., Al-Hajjar, M., Jennings, L.M. and Fisher, J. 2017. Wear and deformation of metal-on-polyethylene hip replacements under edge loading conditions due to variations in surgical positioning In: Orthopaedic Proceedings. The British Editorial Society of Bone & Joint Surgery, p.12. Ali, M., Al-Hajjar, M., Partridge, S., Williams, S., Fisher, J. and Jennings, L.M. 2016. Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 230(5), pp.389–397. Almouahed, S., Gouriou, M., Hamitouche, C., Stindel, E. and Roux, C. 2011. The use of piezoceramics as electrical energy harvesters within instrumented knee implant during walking. IEEE/ASME Transactions on Mechatronics. 16(5), pp.799–807. Alshuhri, A.A., Holsgrove, T.P., Miles, A.W. and Cunningham, J.L. 2015. Development of a non-invasive diagnostic technique for acetabular component loosening in total hip replacements. Medical Engineering and Physics. 37(8), pp.739–745. Amar, A. Ben, Kouki, A.B. and Cao, H. 2015. Power approaches for implantable medical devices. sensors. 15(11), pp.28889–28914. Amstutz, H.C., Lodwig, R.M., Schurman, D.J. and Hodgson, A.G. 1975. Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus. Clinical orthopaedics and related research. (111), pp.124–130. AOA 2018. National Joint Replacement Registry: Hip, Knee & Shoulder Arthroplasty Annual Report 2018. Arami, A., Aminian, K., Forchelet, D. and Renaud, P. 2014. Implantable and wearable measurement system for smart knee prosthesis In: 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings. IEEE, pp.240–243. Arami, A., Simoncini, M., Atasoy, O., Ali, S., Hasenkamp, W., Bertsch, A., Meurville, E., Tanner, S., Renaud, P. and Dehollain, C. 2013. Instrumented knee prosthesis for force and kinematics measurements. IEEE transactions on automation science and engineering. 10(3), pp.615–624. Arami, A., Simoncini, M., Atasoy, O., Hasenkamp, W., Ali, S., Bertsch, A., Meurville, E., Tanner, S., Dejnabadi, H. and Leclercq, V. 2011. Instrumented prosthesis for knee implants monitoring In: 2011 IEEE international conference on automation science and engineering. IEEE, pp.828–835. Asif, Z. and Munir, M. 2005. Integrating the supply chain with RFID: A technical and business analysis. Communications of the Association for Information Systems. 15(1), p.24. Awal, M.R., Jusoh, M., Sabapathy, T., Kamarudin, M.R. and Rahim, R.A. 2016. State-of-the-art developments of acoustic energy transfer. International Journal of Antennas and Propagation. 2016. Balaban, A.L., Bakhvalov, Y.A. and Denisov, P.A. 2018. Review of methods for solving inverse problems in identifying permanent magnets of executive elements in dynamic devices In: MATEC Web of Conferences. EDP Sciences, p.4022. Baumann, A.P., O’Neill, C., Owens, M.C., Weber, S.C., Sivan, S., D’Amico, R., Carmody, S., Bini, S., Sawyer, A.J. and Lotz, J.C. 2020. FDA Public Workshop: Orthopaedic Sensing, Measuring, and Advanced Reporting Technology (SMART) Devices. Journal of orthopaedic research: official publication of the Orthopaedic Research Society. Bergmann, G, Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J. and Duda, G.N. 2001. Hip contact forces and gait patterns from routine activities. Journal of Biomechanics. 34(7), pp.859–871. Bergmann, G., Graichen, F., Dymke, J., Rohlmann, A., Duda, G.N. and Damm, P. 2012. High-tech hip implant for wireless temperature measurements in vivo. PLoS One. 7(8), p.e43489. Bergmann, G., Graichen, F., Jendrzynski, H. and Rohlmann, A. 1987. Long Term Animal Tests with Instrumented Hip Implants In: Biomechanics: Basic and Applied Research. Springer, pp.317–324. Bergmann, G., Graichen, F. and Rohlmann, A. 1993. Hip joint loading during walking and running, measured in two patients. Journal of biomechanics. 26(8), pp.969–990. Bergmann, G., Graichen, F., Rohlmann, A., Verdonschot, N. and van Lenthe, G.H. 2001. Frictional heating of total hip implants, Part 1: measurements in patients. Journal of Biomechanics. 34(4), pp.421–428. Bergmann, G., Graichen, F., Siraky, J., Jendrzynski, H. and Rohlmann, A. 1988. Multichannel strain gauge telemetry for orthopaedic implants. Journal of Biomechanics. 21(2), pp.169–176. Beshchasna, N., Uhlemann, J. and Wolter, K.-J. 2006. Researching of biochemical degradation of electronic materials in fluid electrolytic mediums In: 2006 29th International Spring Seminar on Electronics Technology. IEEE, pp.149–155. Bluetooth.com 2020. Learn about Bluetooth. [Accessed 15 June 2020]. Available from: bluetooth.com. Bock, D.C., Marschilok, A.C., Takeuchi, K.J. and Takeuchi, E.S. 2012. Batteries used to power implantable biomedical devices. Electrochimica acta. 84, pp.155–164. Bosker, B.H., Verheyen, C., Horstmann, W.G. and Tulp, N.J.A. 2007. Poor accuracy of freehand cup positioning during total hip arthroplasty. Archives of orthopaedic and trauma surgery. 127(5), pp.375–379. Bradley, P.D. 2011. Wireless medical implant technology—Recent advances and future developments In: 2011 Proceedings of the European Solid-State Device Research Conference (ESSDERC). IEEE, pp.54–58. British Heart Foundation 2020. Life with a pacemaker: Two inspiring stories. [Accessed 15 June 2020]. Available from: bhf.org.uk. Brown, T.D. and Callaghan, J.J. 2008. (ii) Impingement in total hip replacement: mechanisms and consequences. Current orthopaedics. 22(6), pp.376–391. Burns, A.J., Johnson, M.E. and Honeyman, P. 2016. A brief chronology of medical device security. Communications of the ACM. 59(10), pp.66–72. Camacho, J.M. and Sosa, V. 2013. Alternative method to calculate the magnetic field of permanent magnets with azimuthal symmetry. Revista mexicana de física E. 59(1), pp.8–17. Cao, H., Landge, V., Tata, U., Seo, Y.-S., Rao, S., Tang, S.-J., Tibbals, H.F., Spechler, S. and Chiao, J.-C. 2012. An implantable, batteryless, and wireless capsule with integrated impedance and pH sensors for gastroesophageal reflux monitoring. IEEE Transactions on Biomedical Engineering. 59(11), pp.3131–3139. Carlson, C.E., Mann, R.W. and Harris, W.H. 1974. A radio telemetry device for monitoring cartilage surface pressures in the human hip. IEEE Transactions on Biomedical Engineering. (4), pp.257–264. Çelik, T. and Kisioglu, Y. 2019. Determination of The Hip Stem Loosening Using Vibration Method. European Journal of Engineering and Natural Sciences. 3(1), pp.73–77. Cheney, D. 2013. CBS 60 Minute: Dick Cheney’s Heart. [Accessed 10 November 2020]. Available from: https://www.cbsnews.com/video/dick-cheneys-heart/. Chung, J.K., Pratt, G.W., Babyn, P.S. and Poss, R. 1979. NEW DIAGNOSTIC-TECHNIQUE FOR THE EVALUATION OF PROSTHETIC FIXATION In: IEEE Transactions on Biomedical Engineering. IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC 345 E 47TH ST, NEW YORK, NY …, p.532. CIHI 2018. Hip and Knee Replacements in Canada, 2016–2017: Canadian Joint Replacement Registry Annual Report. Ottawa, ON. Clearswift 2020. Infographic: Cybersecurity challenges in the UK healthcare sector. [Accessed 10 November 2020]. Available from: https://www.clearswift.com/blog/2020/01/22/infographic-cybersecurity-challenges-uk-healthcare-sector. Conaty-Buck, S. 2017. Cybersecurity and healthcare records. American Nurse Today. 12(9), pp.62–64. Cushner, F., Schiller, P., Gross, J., Mueller, J.K. and Hunter, W. 2021. A total knee arthroplasty prosthesis capable of remote patient monitoring In: Orthopaedic Proceedings. The British Editorial Society of Bone & Joint Surgery, p.18. Cushner, F.D., Schiller, P.J., Mueller, J.K.P., Gross, J.M. and Hunter, W.L. 2022. A cadaveric study addressing the feasibility of remote patient monitoring prosthesis for total knee arthroplasty. The Journal of Arthroplasty. 37(6), pp.S350–S354. Damm, P., Dymke, J., Ackermann, R., Bender, A., Graichen, F., Halder, A., Beier, A. and Bergmann, G. 2013. Friction in total hip joint prosthesis measured in vivo during walking. PloS one. 8(11). Damm, P., Graichen, F., Rohlmann, A., Bender, A. and Bergmann, G. 2010. Total hip joint prosthesis for in vivo measurement of forces and moments. Medical engineering & physics. 32(1), pp.95–100. Daou, H.E.L., Ng, K.C.G., Van Arkel, R., Jeffers, J.R.T. and y Baena, F.R. 2019. Robotic hip joint testing: Development and experimental protocols. Medical engineering & physics. 63, pp.57–62. Dargel, J., Oppermann, J., Brüggemann, G.-P. and Eysel, P. 2014. Dislocation following total hip replacement. Deutsches Ärzteblatt International. 111(51–52), p.884. Davies, J.P., Tse, M.-K. and Harris, W.H. 1996. Monitoring the integrity of the cement—metal interface of total joint components in vitro using acoustic emission and ultrasound. The Journal of arthroplasty. 11(5), pp.594–601. Davy, D.T., Kotzar, G.M., Brown, R.H., Heiple, K.G., Goldberg, V.M., Heiple, J.K.G., Berilla, J. and Burstein, A.H. 1988. Telemetric force measurements across the hip after total arthroplasty. The Journal of bone and joint surgery. American volume. 70(1), pp.45–50. Deyle, G. 2005. Diagnostic Imaging in Primary Care Physical Therapy. Primary Care for the Physical Therapist., pp.323-cp4. DHSC 2018. Securing cyber resilience in health and care: October 2018 update. Cyber Security Policy. DiGioia III, A.M., Jaramaz, B., Plakseychuk, A.Y., Moody Jr, J.E., Nikou, C., LaBarca, R.S., Levison, T.J. and Picard, F. 2002. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. The Journal of arthroplasty. 17(3), pp.359–364. Disilvestro, M.R., Sherman, J.T. and Dietz, T.L. 2007. In vivo joint space measurement device and method. Domas, S. 2019. Maybe Your Pacemaker Can’t Kill You. InSecurity [PODCAST]. Domas, S. 2016. Protecting Medical Devices from Cyberharm. Tedx Talks. [Online]. [Accessed 13 August 2020]. Available from: https://www.youtube.com/watch?v=EyqwUFJKZo0. Dorr, L.D., Wolf, A.W., Chandler, R. and Conaty, J.P. 1983. Classification and treatment of dislocations of total hip arthroplasty. Clinical orthopaedics and related research. (173), pp.151–158. English and Kilvington 1979. In vivo records of hip loads using a femoral implant with telemetric output (a prelimary report). Journal of biomedical engineering. 1(2), pp.111–115. Ermakova, A., Ribeiro, M., Spitzer, D. and Ortner, M. 2018. Analytical Development of a Four-Axis Magnetic Multimedia Control Element. IEEE Sensors Journal. 18(19), pp.7819–7825. Ewald, H., Ruther, C., Mittelmeier, W., Bader, R. and Kluess, D. 2011. A novel in vivo sensor for loosening diagnostics in total hip replacement In: SENSORS, 2011 IEEE. IEEE, pp.89–92. FCC 2017. Medical Device Radiocommunications Service. Available from: https://www.fcc.gov/medical-device-radiocommunications-service-medradio. FDA 2015a. Class 2 Device Recall Merlinhome RF Remote Monitoring Transmitter, Model EX1150, with software versions 6.1M or 7.0. FDA 2018a. Content of Premarket Submissions for Management of Cybersecurity in Medical Devices. FDA 2013. Cybersecurity for Medical Devices and Hospital Networks: FDA Safety Communication. [Accessed 10 November 2020]. Available from: http://wayback.archive-it.org/7993/20170722144747/https:/www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm356423.htm. FDA 2018b. Cybersecurity Updates Affecting Medtronic Implantable Cardiac Device Programmers: FDA Safety Communication. [Accessed 10 November 2020]. Available from: https://www.fda.gov/medical-devices/safety-communications/cybersecurity-updates-affecting-medtronic-implantable-cardiac-device-programmers-fda-safety. FDA 2015b. Cybersecurity Vulnerabilities of Hospira Symbiq Infusion System: FDA Safety Communication. [Accessed 10 November 2020]. Available from: https://web.archive.org/web/20170111070001/http:/www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm456815.htm. FDA 2014. GUIDANCE DOCUMENT Content of Premarket Submissions for Management of Cybersecurity in Medical Devices. [Accessed 10 November 2020]. Available from: https://www.fda.gov/regulatory-information/search-fda-guidance-documents/content-premarket-submissions-management-cybersecurity-medical-devices-0. FDA 2018c. Medtronic Recalls Remote Controllers for MiniMed Insulin Pumps for Potential Cybersecurity Risks. FDA 2020. SweynTooth Cybersecurity Vulnerabilities May Affect Certain Medical Devices: FDA Safety Communication. FDA 2019. URGENT/11 Cybersecurity Vulnerabilities in a Widely-Used Third-Party Software Component May Introduce Risks During Use of Certain Medical Devices: FDA Safety Communication. [Accessed 10 November 2020]. Available from: https://www.fda.gov/medical-devices/safety-communications/urgent11-cybersecurity-vulnerabilities-widely-used-third-party-software-component-may-introduce. Gabriel, S., Lau, R.W. and Gabriel, C. 1996. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Physics in medicine & biology. 41(11), p.2271. Geerdink, C.H., Grimm, B., Vencken, W., Heyligers, I.C. and Tonino, A.J. 2008. The determination of linear and angular penetration of the femoral head into the acetabular component as an assessment of wear in total hip replacement: a comparison of four computer-assisted methods. The Journal of Bone and Joint Surgery. British volume. 90(7), pp.839–846. Georgiou, A.P. and Cunningham, J.L. 2001. Accurate diagnosis of hip prosthesis loosening using a vibrational technique. Clinical Biomechanics. 16(4), pp.315–323. Ghaffari, M., Nickmanesh, R., Tamannaee, N. and Farahmand, F. 2012. The impingement-dislocation risk of total hip replacement: Effects of cup orientation and patient maneuvers In: 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE, pp.6801–6804. Ghorbani, S., Mahdaviani, K., Thaler, A., Kording, K., Cook, D.J., Blohm, G. and Troje, N.F. 2021. MoVi: A large multi-purpose human motion and video dataset. Plos one. 16(6), p.e0253157. Girase, H., Nyayapati, P., Booker, J., Lotz, J.C., Bailey, J.F. and Matthew, R.P. 2021. Automated assessment and classification of spine, hip, and knee pathologies from sit-to-stand movements collected in clinical practice. Journal of Biomechanics. 128, p.110786. Goodin, D. 2011. Insulin pump hack delivers fatal dosage over the air. theregister. [Online]. [Accessed 10 November 2020]. Available from: https://www.theregister.com/2011/10/27/fatal_insulin_pump_attack/. Graichen, F. and Bergmann, G. 1991. Four-channel telemetry system for in vivo measurement of hip joint forces. Journal of biomedical engineering. 13(5), pp.370–374. Graichen, F., Bergmann, G. and Rohlmann, A. 1999. Hip endoprosthesis for in vivo measurement of joint force and temperature. Journal of biomechanics. 32(10), pp.1113–1117. Gray, P. 2012. Pacemakers, defibrillators open to attack. theregister. [Online]. [Accessed 10 November 2020]. Available from: https://www.theregister.com/2012/10/17/pacemakers_open_to_wireless_attack/. Grillini, L. and Affatato, S. 2013. How to measure wear following total hip arthroplasty. Hip International. 23(3), pp.233–242. Guevara-Valdivia, M.E. and Torres, P.I. 2011. Remote Monitoring of Implantable Pacemaker, Cardioverter Defibrillator, and Cardiac Resynchronizer, Modern Pacemakers - Present and Future, Prof. Mithilesh R Das. Hadley, M., Hardaker, C., Isaac, G. and Fisher, J. 2018. Wear of different materials for total hip replacement under adverse stop-dwell-start in vitro wear simulation conditions. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 232(12), pp.1261–1270. Halperin, D., Heydt-Benjamin, T.S., Ransford, B., Clark, S.S., Defend, B., Morgan, W., Fu, K., Kohno, T. and Maisel, W.H. 2008. Pacemakers and implantable cardiac defibrillators: Software radio attacks and zero-power defenses In: 2008 IEEE Symposium on Security and Privacy (sp 2008). IEEE, pp.129–142. Hammerberg, E.M., Wan, Z., Dastane, M. and Dorr, L.D. 2010. Wear and Range of Motion of Different Femoral Head Sizes. The Journal of Arthroplasty. 25(6), pp.839–843. Hassan, D.M., Johnston, G.H.F., Dust, W.N.C., Watson, G. and Dolovich, A.T. 1998. Accuracy of intraoperative assessment of acetabular prosthesis placement. The Journal of Arthroplasty. 13(1), pp.80–84. Henderson, D.M. 1977. Euler angles, quaternions, and transformation matrices for space shuttle analysis. Herrmann, S., Kaehler, M., Grawe, R., Kluess, D., Woernle, C. and Bader, R. 2015. Physiological-like testing of the dislocation stability of artificial hip joints In: New Trends in Mechanism and Machine Science: From Fundamentals to Industrial Applications. Springer, pp.659–667. Islam, M.N. and Yuce, M.R. 2016. Review of Medical Implant Communication System (MICS) band and network. ICT Express. 2(4), pp.188–194. Jantara, V.L. 2020. Wind turbine gearboxes: Failures, surface treatments and condition monitoring. Non-Destructive Testing and Condition Monitoring Techniques for Renewable Energy Industrial Assets., pp.69–90. Jaramaz, B., Nikou, C., Simon, D.A. and DiGioia, A.M. 1997. Range of motion after total hip arthroplasty: Experimental verification of the analytical simulator In: CVRMed-MRCAS’97. Springer, pp.573–582. Jones, D., Wang, L., Ghanbari, A., Vardakastani, V., Kedgley, A.E., Gardiner, M.D., Vincent, T.L., Culmer, P.R. and Alazmani, A. 2020. Design and evaluation of magnetic Hall effect tactile sensors for use in sensorized splints. Sensors. 20(4), p.1123. Joung, Y.-H. 2013. Development of implantable medical devices: from an engineering perspective. International neurourology journal. 17(3), p.98. Kebbach, M., Grawe, R., Geier, A., Winter, E., Bergschmidt, P., Kluess, D., D’Lima, D., Woernle, C. and Bader, R. 2019. Effect of surgical parameters on the biomechanical behaviour of bicondylar total knee endoprostheses–A robot-assisted test method based on a musculoskeletal model. Scientific reports. 9(1), p.14504. Kelmers, E., Szuba, A., King, S.W., Palan, J., Freear, S., Pandit, H.G. and van Duren, B.H. 2022. Smart Knee Implants: An Overview of Current Technologies and Future Possibilities. Indian Journal of Orthopaedics., pp.1–8. Kennedy, J.G., Rogers, W.B., Soffe, K.E., Sullivan, R.J., Griffen, D.G. and Sheehan, L.J. 1998. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. The Journal of arthroplasty. 13(5), pp.530–534. Khan, W. and Badii, A. 2019. Pathological gait abnormality detection and segmentation by processing the hip joints motion data to support mobile gait rehabilitation. Research in C Medical & Engineering Sciences. 7(03). Khokle, R., Esselle, K. and Bokor, D. 2018. Design, Modeling, and Evaluation of the Eddy Current Sensor Deeply Implanted in the Human Body. Sensors. 18(11), p.3888. Kilvington, M. and Goodman, R.M.F. 1981. In vivo hip joint forces recorded on a strain gauged ‘English’prosthesis using an implanted transmitter. Engineering in Medicine. 10(4), pp.175–187. Kim, J.T. and Yoo, J.J. 2016. Implant design in cementless hip arthroplasty. Hip & pelvis. 28(2), pp.65–75. Kiourti, A., Costa, J.R., Fernandes, C.A. and Nikita, K.S. 2014. A broadband implantable and a dual-band on-body repeater antenna: Design and transmission performance. IEEE transactions on antennas and propagation. 62(6), pp.2899–2908. Kirsten, S., Uhlemann, J., Braunschweig, M. and Wolter, K.J. 2012. Packaging of electronic devices for long-term implantation In: 2012 35th International Spring Seminar on Electronics Technology. IEEE, pp.123–127. Knight, S.R., Aujla, R. and Biswas, S.P. 2011. Total Hip Arthroplasty-over 100 years of operative history. Orthopedic reviews. 3(2). Komistek, R.D., Dennis, D.A., Ochoa, J.A., Haas, B.D. and Hammill, C. 2002. In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty. JBJS. 84(10), pp.1836–1841. Kotzar, G.M., Davy, D.T., Goldberg, V.M., Heiple, K.G., Berilla, J., Heiple Jr, K.G., Brown, R.H. and Burstein, A.H. 1991. Telemeterized in vivo hip joint force data: a report on two patients after total hip surgery. Journal of Orthopaedic Research. 9(5), pp.621–633. Lachiewicz, P.F., Soileau, E.S. and Martell, J.M. 2016. Wear and osteolysis of highly crosslinked polyethylene at 10 to 14 years: the effect of femoral head size. Clinical Orthopaedics and Related Research®. 474(2), pp.365–371. Lange, H.-E., Hohlfeld, D., Bader, R. and Kluess, D. 2020. A piezoelectric energy harvesting concept for an energy-autonomous instrumented total hip replacement. Smart Materials and Structures. Learmonth, I.D., Young, C. and Rorabeck, C. 2007. The operation of the century: total hip replacement. The Lancet. 370(9597), pp.1508–1519. Ledet, E.H., Liddle, B., Kradinova, K. and Harper, S. 2018. Smart implants in orthopedic surgery, improving patient outcomes: a review. Innovation and entrepreneurship in health. 5, p.41. Lewinnek, G.E., Lewis, J.L., Tarr, R., Compere, C.L. and Zimmerman, J.R. 1978. Incidence of dislocation following hip arthroplasty for patients in the rehabilitation setting. J Bone Joint Surg Am. 60(2), pp.217–220. Li, P.L.S., Jones, N.B. and Gregg, P.J. 1996. Vibration analysis in the detection of total hip prosthetic loosening. Medical engineering & physics. 18(7), pp.596–600. Liu, Q., Cheng, X., Yan, D. and Zhou, Y. 2019. Plain radiography findings to predict dislocation after total hip arthroplasty. Journal of Orthopaedic Translation. Lombardi Jr, A. V, Mallory, T.H., Dennis, D.A., Komistek, R.D., Fada, R.A. and Northcut, E.J. 2000. An in vivo determination of total hip arthroplasty pistoning during activity. The Journal of Arthroplasty. 15(6), pp.702–709. Lumetti, S., Malagò, P., Spitzer, D., Zaruba, S. and Ortner, M. 2020. Computationally Efficient Magnetic Position System Calibration In: Engineering Proceedings. Multidisciplinary Digital Publishing Institute, p.72. Luo, Y., Coppola, S.M., Dixon, P.C., Li, S., Dennerlein, J.T. and Hu, B. 2020. A database of human gait performance on irregular and uneven surfaces collected by wearable sensors. Scientific data. 7(1), p.219. Lutz., C. and Foletto., A. 2019. Joystick with Allegro Position Sensor IC. Maag, C., Metcalfe, A., Cracaoanu, I., Wise, C. and Auger, D.D. 2021. The development of simulator testing for total knee replacements. Biosurface and Biotribology. 7(2), pp.70–82. Maggs, J. and Wilson, M. 2017. The relative merits of cemented and uncemented prostheses in total hip arthroplasty. Indian journal of orthopaedics. 51(4), p.377. Malagò, P., Slanovc, F., Herzog, S., Lumetti, S., Schaden, T., Pellegrinetti, A., Moridi, M., Abert, C., Suess, D. and Ortner, M. 2020. Magnetic Position System Design Method Applied to Three-Axis Joystick Motion Tracking. Sensors. 20(23), p.6873. Malik, A., Maheshwari, A. and Dorr, L.D. 2007. Impingement with total hip replacement. JBJS. 89(8), pp.1832–1842. Maneewongvatana, S. and Mount, D.M. 1999. Analysis of approximate nearest neighbor searching with clustered point sets. arXiv preprint cs/9901013. Marchetti, E., Krantz, N., Berton, C., Bocquet, D., Fouilleron, N., Migaud, H. and Girard, J. 2011. Component impingement in total hip arthroplasty: frequency and risk factors. A continuous retrieval analysis series of 416 cup. Orthopaedics & Traumatology: Surgery & Research. 97(2), pp.127–133. Marschner, U., Grätz, H., Jettkant, B., Ruwisch, D., Woldt, G., Fischer, W.-J. and Clasbrummel, B. 2009. Integration of a wireless lock-in measurement of hip prosthesis vibrations for loosening detection. Sensors and Actuators A: Physical. 156(1), pp.145–154. Matharu, G.S., Culliford, D.J., Blom, A.W. and Judge, A. 2022. Projections for primary hip and knee replacement surgery up to the year 2060: an analysis based on data from The National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. The Annals of The Royal College of Surgeons of England. 104(6), pp.443–448. Mathworks 2021. Levenberg-Marquardt backpropagation. Available from: https://uk.mathworks.com/help/deeplearning/ref/trainlm.html. MathWorks 2019. magcal. [Accessed 27 February 2024]. Available from: https://uk.mathworks.com/help/nav/ref/magcal.html. Mavrogordato, M., Taylor, M., Taylor, A. and Browne, M. 2011. Real time monitoring of progressive damage during loading of a simplified total hip stem construct using embedded acoustic emission sensors. Medical engineering & physics. 33(4), pp.395–406. McCalden, R.W., Naudie, D.D., Yuan, X. and Bourne, R.B. 2005. Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. JBJS. 87(10), pp.2323–2334. McKellop, H.A. 2007. The lexicon of polyethylene wear in artificial joints. Biomaterials. 28(34), pp.5049–5057. McKellop, H.A. and D’Lima, D. 2008. How have wear testing and joint simulator studies helped to discriminate among materials and designs? JAAOS-Journal of the American Academy of Orthopaedic Surgeons. 16, pp.S111–S119. MDCG 2019. MDCG 2019-16 - Guidance on Cybersecurity for medical devices. Melexis 2021. How to use a magnetometer in a position sensor application. Melia, G. 2013. Electromagnetic absorption by the human body from 1-15 GHz. (Doctoral Dissertation, University of York). Mentiplay, B.F., Banky, M., Clark, R.A., Kahn, M.B. and Williams, G. 2018. Lower limb angular velocity during walking at various speeds. Gait & posture. 65, pp.190–196. Mohammadbagherpoor, H., Ierymenko, P., Craver, M.H., Carlson, J., Dausch, D., Grant, E. and Lucey, J.D. 2019. An Implantable Wireless Inductive Sensor System Designed To Monitor Prosthesis Motion in Total Joint Replacement Surgery. IEEE Transactions on Biomedical Engineering. Muro-De-La-Herran, A., Garcia-Zapirain, B. and Mendez-Zorrilla, A. 2014. Gait analysis methods: An overview of wearable and non-wearable systems, highlighting clinical applications. Sensors. 14(2), pp.3362–3394. Murray, D.W. 1992. Impingement and loosening of the long posterior wall acetabular implant. The Journal of bone and joint surgery. British volume. 74(3), pp.377–379. Murray, D.W. 1993. The definition and measurement of acetabular orientation. The Journal of bone and joint surgery. British volume. 75(2), pp.228–232. Nagymáté, G. and Kiss, R.M. 2018. Application of OptiTrack motion capture systems in human movement analysis: A systematic literature review. Recent Innovations in Mechatronics. 5(1.), pp.1–9. National Joint Registry 2020. 17th Annual Report 2020. [Accessed 13 November 2020]. Available from: https://reports.njrcentre.org.uk/Portals/0/PDFdownloads/NJR 17th Annual Report 2020.pdf. Nelson, B.D., Karipott, S.S., Wang, Y. and Ong, K.G. 2020. Wireless Technologies for Implantable Devices. Sensors. 20(16), p.4604. NHS 2023. Osteoarthritis. Available from: https://www.nhs.uk/conditions/osteoarthritis/. NJR 2018. NJR 15th Annual Report 2018. NJR 2022. NJR Report 2022. Available from: https://www.njrcentre.org.uk/. NOAA - NCEI 2024. Geomagnetism Frequently Asked Questions. Available from: www.ncei.noaa.gov/. O’Dwyer Lancaster‐Jones, O., Williams, S., Jennings, L.M., Thompson, J., Isaac, G.H., Fisher, J. and Al‐Hajjar, M. 2018. An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements. Journal of Biomedical Materials Research Part B: Applied Biomaterials. 106(5), pp.1897–1906. OptiTrack 2023. OptiTrack for Movement Sciences. Available from: optitrack.com. Orthload 2019. Loading of Orthopaedic Implants. [Accessed 30 January 2020]. Available from: https://orthoload.com/. Orthopaedic Design & Technology 2021. First Knee Replacement Surgery with Persona IQ Smart Knee. [Accessed 2 June 2023]. Available from: https://www.odtmag.com/contents/view_breaking-news/2021-10-13/first-knee-replacement-surgery-with-persona-iq-smart-knee/. Ortho-tag 2020. Ortho-tag. [Accessed 18 November 2020]. Available from: www.orthotag.com/. Ortner, M., Ribeiro, M. and Spitzer, D. 2018. Absolute long-range linear position system with a single 3-D magnetic field sensor. IEEE Transactions on Magnetics. 55(1), pp.1–4. Otake, Y., Suzuki, N., Hattori, A., Hayashibe, M., Miki, H., Yamamura, M., Sugano, N., Yonenobu, K. and Ochi, T. 2005. Soft-Tissue Balance Evaluation System for Total Hip Arthroplasty by Intraoperative Contact Pressure Measurement at the Hip Joint. Studies in health technology and informatics. 119, p.416. Ozeri, S. and Shmilovitz, D. 2010. Ultrasonic transcutaneous energy transfer for powering implanted devices. Ultrasonics. 50(6), pp.556–566. Ozyagcilar, T. 2012. Calibrating an ecompass in the presence of hard and soft-iron interference. Freescale Semiconductor Ltd., pp.1–17. Padgett, D.E. and Warashina, H. 2004. The unstable total hip replacement. Clinical Orthopaedics and Related Research®. 420, pp.72–79. Pancharoen, K., Zhu, D. and Beeby, S.P. 2014. A hip implant energy harvester In: Journal of Physics: Conference Series. IOP Publishing, p.12038. Panero, E., Digo, E., Agostini, V. and Gastaldi, L. 2018. Comparison of different motion capture setups for gait analysis: Validation of spatio-temporal parameters estimation In: 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA). IEEE, pp.1–6. Parvizi, J., Kim, G.K., Parvizi, J. and Kim, G.K. 2010. Bone Scan. High Yield Orthopaedics., pp.66–67. Pounds, G. 2023. Development of a Novel Motion-Capture Methodology to Assess Medial Meniscus Displacement during Cadaveric Gait Simulation [IN PRINT]. University of Leeds. Pryce, G., Al-Hajjar, M., Thompson, J., Wilcox, R., Board, T. and Williams, S. 2021. AN IN VITRO METHOD TO INVESTIGATE IMPLANT IMPINGEMENT OF HIP ARTHROPLASTIES In: Orthopaedic Proceedings. The British Editorial Society of Bone & Joint Surgery, p.21. Pryce, G.M. 2019. PhD: Polyethylene acetabular liner rim damage in total hip replacements. University of Leeds, White Rose eTheses Online. Pryce, G.M., Sabu, B., Al-Hajjar, M., Wilcox, R.K., Thompson, J., Isaac, G.H., Board, T. and Williams, S. 2022. Impingement in total hip arthroplasty: A geometric model. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 236(4), pp.504–514. Puers, R., Catrysse, M., Vandevoorde, G., Collier, R.J., Louridas, E., Burny, F., Donkerwolcke, M. and Moulart, F. 2000. A telemetry system for the detection of hip prosthesis loosening by vibration analysis. Sensors and Actuators A: Physical. 85(1–3), pp.42–47. Rieger, J.S., Jaeger, S., Schuld, C., Kretzer, J.P. and Bitsch, R.G. 2013. A vibrational technique for diagnosing loosened total hip endoprostheses: An experimental sawbone study. Medical engineering & physics. 35(3), pp.329–337. Rittmeister, M. and Callitsis, C. 2006. Factors influencing cup orientation in 500 consecutive total hip replacements. Clinical Orthopaedics and Related Research®. 445, pp.192–196. Roithmayr, C.M., Hodges, D.H. and Cross, P. 2016. Dynamics: Theory and Application of Kane’s Method [Online]. Cambridge University Press. Available from: https://books.google.co.uk/books?id=dKizCwAAQBAJ. Roques, A., Browne, M., Thompson, J., Rowland, C. and Taylor, A. 2004. Investigation of fatigue crack growth in acrylic bone cement using the acoustic emission technique. Biomaterials. 25(5), pp.769–778. Rosenstein, A.D., McCoy, G.F., Bulstrode, C.J., McLardy-Smith, P.D., Cunningham, J.L. and Turner-Smith, A.R. 1989. The differentiation of loose and secure femoral implants in total hip replacement using a vibrational technique: an anatomical and pilot clinical study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 203(2), pp.77–81. Rowland, C., Browne, M., Taylor, A. and Leatherhead, U.K. 2004. Dynamic health monitoring of metal on metal hip prostheses using acoustic emission In: 26th European conference on acoustic emission testing. Citeseer, pp.465–467. Rowlands, A., Duck, F.A. and Cunningham, J.L. 2008. Bone vibration measurement using ultrasound: Application to detection of hip prosthesis loosening. Medical engineering & physics. 30(3), pp.278–284. Ruther, C., Ewald, H., Mittelmeier, W., Bader, R. and Kluess, D. 2010. Localization of uncemented hip Stem loosening with a novel in-vivo sensor system based on vibration analysis In: 6th World Congress of Biomechanics (WCB 2010). August 1-6, 2010 Singapore. Springer, pp.620–623. Ruther, C., Gabler, C., Ewald, H., Ellenrieder, M., Haenle, M., Lindner, T., Mittelmeier, W., Bader, R. and Kluess, D. 2014. In vivo monitoring of implant osseointegration in a rabbit model using acoustic sound analysis. Journal of Orthopaedic Research. 32(4), pp.606–612. Ruther, C., Timm, U., Ewald, H., Mittelmeier, W., Bader, R., Schmelter, R., Lohrengel, A. and Kluess, D. 2012. Current possibilities for detection of loosening of total hip replacements and how intelligent implants could improve diagnostic accuracy In: Recent advances in arthroplasty. IntechOpen. Rychlik, M., Wendland, G., Jackowski, M., Rennert, R., Schaser, K.-D. and Nowotny, J. 2023. Calibration procedure and biomechanical validation of an universal six degree-of-freedom robotic system for hip joint testing. Journal of Orthopaedic Surgery and Research. 18(1), p.164. Rydell, N.W. 1966. Forces acting on the femoral head-prosthesis: a study on strain gauge supplied prostheses in living persons. Acta Orthopaedica Scandinavica. 37(sup88), pp.1–132. Sample, A.P., Yeager, D.J., Powledge, P.S., Mamishev, A. V and Smith, J.R. 2008. Design of an RFID-based battery-free programmable sensing platform. IEEE transactions on instrumentation and measurement. 57(11), pp.2608–2615. Sauer, S., Kirsten, S., Storck, F., Grätz, H., Marschner, U., Ruwisch, D. and Fischer, W.-J. 2013. A medical wireless measurement system for hip prosthesis loosening detection based on vibration analysis. Sensors & Transducers. 18(1), p.134. Scifert, C.F., Brown, T.D. and Lipman, J.D. 1999. Finite element analysis of a novel design approach to resisting total hip dislocation. Clinical Biomechanics. 14(10), pp.697–703. Sejdić, E., Rothfuss, M.A., Stachel, J.R., Franconi, N.G., Bocan, K., Lovell, M.R. and Mickle, M.H. 2013. Innovation and translation efforts in wireless medical connectivity, telemedicine and eMedicine: a story from the RFID Center of Excellence at the University of Pittsburgh. Annals of biomedical engineering. 41(9), pp.1913–1925. Semlitsch, M. and Willert, H.G. 1997. Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 211(1), pp.73–88. Shadid, R. and Noghanian, S. 2018. A literature survey on wireless power transfer for biomedical devices. International Journal of Antennas and Propagation. 2018. SHAR 2017. Swedish Hip Arthroplasty Register Annual Report 2017. Shon, W.Y., Baldini, T., Peterson, M.G., Wright, T.M. and Salvati, E.A. 2005. Impingement in total hip arthroplasty: a study of retrieved acetabular components. The Journal of arthroplasty. 20(4), pp.427–435. Siciliano, B., Khatib, O. and Kröger, T. 2008. Springer handbook of robotics. Springer. Silva, N.M., Santos, P.M., Ferreira, J.A.F., dos Santos, M.P.S., Ramos, A., Simões, J.A.O., Reis, M. and Morais, R. 2013. Power management architecture for smart hip prostheses comprising multiple energy harvesting systems. Sensors and Actuators A: physical. 202, pp.183–192. Singh, J.A., Yu, S., Chen, L. and Cleveland, J.D. 2019. Rates of total joint replacement in the United States: future projections to 2020–2040 using the national inpatient sample. The Journal of rheumatology. 46(9), pp.1134–1140. Soares dos Santos, M.P., Ferreira, J.A.F., Ramos, A., Simões, J.A.O., Morais, R., Silva, N.M., Santos, P.M., Reis, M.C. and Oliveira, T. 2014. Instrumented hip joint replacements, femoral replacements and femoral fracture stabilizers. Expert review of medical devices. 11(6), pp.617–635. Soares dos Santos, M.P., Ferreira, J.A.F., Ramos, A., Simões, J.A.O., Morais, R., Silva, N.M., Santos, P.M., Reis, M.J.C.S. and Oliveira, T. 2013. Instrumented hip implants: Electric supply systems. Journal of Biomechanics. 46(15), pp.2561–2571. Southampton, U.H. 2018. Press release: Doctors implant and programme pacemaker using Bluetooth technology. [Accessed 15 June 2020]. Available from: uhs.nhs.uk/. Souto, G., Muralter, F., Arjona, L., Landaluce, H. and Perallos, A. 2019. Protocol for Streaming Data from an RFID Sensor Network. Sensors. 19(14), p.3148. Stryker 2023. MotionSense with OrthoLogIQ. Where innovation meets recovery. Sugiyama, H., Whiteside, L.A. and Kaiser, A.D. 1989. Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission. Clinical orthopaedics and related research. (249), pp.122–128. Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P. and Gretzer, C. 2006. Aseptic loosening, not only a question of wear: a review of different theories. Acta orthopaedica. 77(2), pp.177–197. Teeter, M., Lam, K., Howard, J., Lanting, B. and Yuan, X. 2016. RADIOSTEREOMETRIC ANALYSIS USING CLINICAL RADIOGRAPHIC VIEWS: MEASURING TOTAL HIP CUP POSITION AND WEAR In: Orthopaedic Proceedings. The British Editorial Society of Bone & Joint Surgery, p.5. Temmerman, O.P.P., Raijmakers, P., Berkhof, J., Hoekstra, O.S., Teule, G.J.J. and Heyligers, I.C. 2005. Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis. The Journal of bone and joint surgery. British volume. 87(6), pp.781–785. Teshome, A.K., Kibret, B. and Lai, D.T.H. 2018. A review of implant communication technology in WBAN: Progress and challenges. IEEE reviews in biomedical engineering. 12, pp.88–99. Tesla, N. 1900. System of transmission of electrical energy. TracPatch Health 2021. TracPatch. Turley, G.A., Ahmed, S.M.Y., Williams, M.A. and Griffin, D.R. 2011. Establishing a range of motion boundary for total hip arthroplasty. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 225(8), pp.769–782. Uhlemann, J., Schindler, S., Schlottig, G., Drechsler, M., Starcke, S., Vollmer, G. and Wolter, K.-J. 2005. Cytotoxicity of COB materials In: Proceedings Electronic Components and Technology, 2005. ECTC’05. IEEE, pp.593–596. Usrey, M.M., Noble, P.C., Rudner, L.J., Conditt, M.A., Birman, M. V, Santore, R.F. and Mathis, K.B. 2006. Does neck/liner impingement increase wear of ultrahigh-molecular-weight polyethylene liners? The Journal of arthroplasty. 21(6), pp.65–71. Varga, M. and Wolter, K.-J. 2014. Sensors and imaging methods for detecting loosening of orthopedic implants—a review In: 2014 IEEE 20th International Symposium for Design and Technology in Electronic Packaging (SIITME). IEEE, pp.333–335. Vena, A., Sorli, B., Charlot, B. and Naudi, S. 2015. An RFID-based implant for identification and pressure sensing of orthopedic prosthesis In: 2015 1st URSI Atlantic Radio Science Conference (URSI AT-RASC). IEEE, p.1. Vickers, O.G., Culmer, P.R., Isaac, G.H., Kay, R.W., Shuttleworth, M.P., Board, T. and Williams, S. 2021. Is in vivo sensing in a total hip replacement a possibility? A review on past systems and future challenges. Progress in Biomedical Engineering. 3(4), p.42004. Virtanen, P., Gommers, R., Oliphant, T.E., Haberland, M., Reddy, T., Cournapeau, D., Burovski, E., Peterson, P., Weckesser, W. and Bright, J. 2020. SciPy 1.0: fundamental algorithms for scientific computing in Python. Nature methods. 17(3), pp.261–272. Wageningen, D. van and Waffenschmidt, E. 2018. Basic principle of inductive power transmission. [Accessed 14 June 2020]. Available from: http://www.wirelesspowerconsortium.com/. Wevers and Surgeon 2000. Acoustic Emission and Composites. Comprehensive Composite Materials., pp.345–357. WHO 1993. Electromagnetic fields (300 Hz to 300 GHz / published under the joint sponsorship of the United Nations Environment Programme, the International Radiation Protection Association, and the World Health Organization. World Health Organization. Williams, S., Butterfield, M., Stewart, T., Ingham, E., Stone, M. and Fisher, J. 2003. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 217(2), pp.147–153. Williams, S.P. 2022. PhD: Impingement in total hip replacements. University of Leeds, White Rose eTheses Online. Wooley, P.H. and Schwarz, E.M. 2004. Aseptic loosening. Gene therapy. 11(4), p.402. Xiao, Z., Tan, X., Chen, X., Chen, S., Zhang, Z., Zhang, H., Wang, J., Huang, Y., Zhang, P. and Zheng, L. 2015. An implantable RFID sensor tag toward continuous glucose monitoring. IEEE journal of biomedical and health informatics. 19(3), pp.910–919. Yao, M. 2017. Your Electronic Medical Records Could Be Worth $1000 To Hackers. Forbes. [Online]. [Accessed 9 November 2020]. Available from: www.forbes.com/. Zimmer Biomet 2023. Persona IQ, The Smart Knee."],"dcterms:accessrights":["public"],"dc:title":["Integrating sensors into total hip replacements"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Integrated Ph.D and Master"],"person:identifier.orcid":["0000000206825148"]},"updated_at":"2026-11-18T23:25:57Z"}