{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:35026"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:35026","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Advances in near-field electron ptychography","abstract":"Over the past few years, ptychography has drawn considerable attention for its ability to recover high contrast and ultra-high resolution images without the need for high quality optics. In its conventional form, it is a type of scanned-probe microscopy, in which a convergent beam – the ptychographic probe – illuminates a small patch of a sample, and then scans through a grid of positions to cover a region of interest, recording diffraction patterns at each point in the grid. Near-field ptychography, originally proposed as a tool to image a larger field of view, was first demonstrated with X-ray and quickly extended to visible light and electron microscopy. In X-ray and visible light community, the near-field ptychography was well explored and combined with multislice and tomography to image three-dimensional samples. Previously, near-field electron ptychography has been proved to be able to image a much larger field of view with fewer diffraction patterns. This thesis keeps exploring the performance of the near-field ptychography with electron microscopy. Our novel design of the amplitude diffuser together with the new experimental arrangement make better use of electron dose and reduce inelastic scattering. The variable magnifications are possible in this geometry, via appropriate adjustment of condenser and projection lens settings. Next, our setup is extended to image the magnetic sample in Lorentz TEM mode. Finally, we make the first attempt at achieving atomic resolution and imaging biological specimens under low voltage conditions using this technique.","abstract_html":"Over the past few years, ptychography has drawn considerable attention for its ability to recover high contrast and ultra-high resolution images without the need for high quality optics. In its conventional form, it is a type of scanned-probe microscopy, in which a convergent beam – the ptychographic probe – illuminates a small patch of a sample, and then scans through a grid of positions to cover a region of interest, recording diffraction patterns at each point in the grid. Near-field ptychography, originally proposed as a tool to image a larger field of view, was first demonstrated with X-ray and quickly extended to visible light and electron microscopy. In X-ray and visible light community, the near-field ptychography was well explored and combined with multislice and tomography to image three-dimensional samples. Previously, near-field electron ptychography has been proved to be able to image a much larger field of view with fewer diffraction patterns. This thesis keeps exploring the performance of the near-field ptychography with electron microscopy. Our novel design of the amplitude diffuser together with the new experimental arrangement make better use of electron dose and reduce inelastic scattering. The variable magnifications are possible in this geometry, via appropriate adjustment of condenser and projection lens settings. Next, our setup is extended to image the magnetic sample in Lorentz TEM mode. Finally, we make the first attempt at achieving atomic resolution and imaging biological specimens under low voltage conditions using this technique.","abstract_has_math":false,"creators":["You, Shengbo"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Maiden, Andrew","Rodenburg, John","Walther, Thomas"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-09","date_published":"2023-09","updated_at":"2026-11-18T23:26:40Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0009000807399903"],"render_values":[{"text":"0009-0008-0739-9903","href":"https://orcid.org/0009-0008-0739-9903","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/35026/1/You%20Shengbo%20190268831%20-%20corrected.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A35026","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Maiden, Andrew","Rodenburg, John","Walther, Thomas"]},{"key":"dc:creator","label":"Author","values":["You, Shengbo"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0009000807399903"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-09"]},{"key":"dc:date.issued","label":"Date","values":["2023-09"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Electronic and Electrical Engineering (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/35026/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/35026/1/You%20Shengbo%20190268831%20-%20corrected.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Over the past few years, ptychography has drawn considerable attention for its ability to recover high contrast and ultra-high resolution images without the need for high quality optics. In its conventional form, it is a type of scanned-probe microscopy, in which a convergent beam – the ptychographic probe – illuminates a small patch of a sample, and then scans through a grid of positions to cover a region of interest, recording diffraction patterns at each point in the grid. Near-field ptychography, originally proposed as a tool to image a larger field of view, was first demonstrated with X-ray and quickly extended to visible light and electron microscopy. In X-ray and visible light community, the near-field ptychography was well explored and combined with multislice and tomography to image three-dimensional samples. Previously, near-field electron ptychography has been proved to be able to image a much larger field of view with fewer diffraction patterns. This thesis keeps exploring the performance of the near-field ptychography with electron microscopy. Our novel design of the amplitude diffuser together with the new experimental arrangement make better use of electron dose and reduce inelastic scattering. The variable magnifications are possible in this geometry, via appropriate adjustment of condenser and projection lens settings. Next, our setup is extended to image the magnetic sample in Lorentz TEM mode. Finally, we make the first attempt at achieving atomic resolution and imaging biological specimens under low voltage conditions using this technique."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Advances in near-field electron ptychography"]}]}],"canonical_facts":{"dc:contributor.advisor":["Maiden, Andrew","Rodenburg, John","Walther, Thomas"],"dc:creator":["You, Shengbo"],"dc:date":["2023-09"],"dc:date.issued":["2023-09"],"dc:description.abstract":["Over the past few years, ptychography has drawn considerable attention for its ability to recover high contrast and ultra-high resolution images without the need for high quality optics. In its conventional form, it is a type of scanned-probe microscopy, in which a convergent beam – the ptychographic probe – illuminates a small patch of a sample, and then scans through a grid of positions to cover a region of interest, recording diffraction patterns at each point in the grid. Near-field ptychography, originally proposed as a tool to image a larger field of view, was first demonstrated with X-ray and quickly extended to visible light and electron microscopy. In X-ray and visible light community, the near-field ptychography was well explored and combined with multislice and tomography to image three-dimensional samples. Previously, near-field electron ptychography has been proved to be able to image a much larger field of view with fewer diffraction patterns. This thesis keeps exploring the performance of the near-field ptychography with electron microscopy. Our novel design of the amplitude diffuser together with the new experimental arrangement make better use of electron dose and reduce inelastic scattering. The variable magnifications are possible in this geometry, via appropriate adjustment of condenser and projection lens settings. Next, our setup is extended to image the magnetic sample in Lorentz TEM mode. Finally, we make the first attempt at achieving atomic resolution and imaging biological specimens under low voltage conditions using this technique."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/35026/1/You%20Shengbo%20190268831%20-%20corrected.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Electronic and Electrical Engineering (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/35026/"],"dcterms:accessrights":["public"],"dc:title":["Advances in near-field electron ptychography"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0009000807399903"]},"updated_at":"2026-11-18T23:26:40Z"}