{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:35200"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:35200","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Development of a Pulsed Optical Pumped Rubidium Clock","abstract":"Since the first ammonia clock in 1949, atomic clocks have been developed to provide improved frequency stability as well as miniature designs capable of being worn on the wrist. With a small number of notable exceptions, most research activity has been directed at improving clock accuracy without regard to power or size, or with very constrained power and volume goals. A design that offers improved frequency stability, within a moderate volume, and that can be used whilst moving, would prove a widely useful reference in laboratory, communication, and navigation applications. To fill this gap, this thesis uses simplified apparatus to achieve the Pulsed Optical Pumping (POP) technique; proves the viability of an alternative to a conventional cylindrical cavity; develops a higher-resolution Digital to Analog Convertor (DAC) than anything commercially available; and does so in a way that can fit within the volume of a shoebox. Limiting factors to the performance of a 85Rb cell are calculated, and a central Ramsey fringe with 100 Hz Full Width at Half Maximum (FWHM) is achieved. A route to demonstrating long-term stability of 2x10-14 (τ=100sec) whilst maintaining -123 dBc/Hz (1Hz offset) close-to-carrier phase noise is provided. The clock’s performance has not been measured as the laser and microwave locking loops are not fully functional.","abstract_html":"Since the first ammonia clock in 1949, atomic clocks have been developed to provide improved frequency stability as well as miniature designs capable of being worn on the wrist. With a small number of notable exceptions, most research activity has been directed at improving clock accuracy without regard to power or size, or with very constrained power and volume goals. A design that offers improved frequency stability, within a moderate volume, and that can be used whilst moving, would prove a widely useful reference in laboratory, communication, and navigation applications. To fill this gap, this thesis uses simplified apparatus to achieve the Pulsed Optical Pumping (POP) technique; proves the viability of an alternative to a conventional cylindrical cavity; develops a higher-resolution Digital to Analog Convertor (DAC) than anything commercially available; and does so in a way that can fit within the volume of a shoebox. Limiting factors to the performance of a 85Rb cell are calculated, and a central Ramsey fringe with 100 Hz Full Width at Half Maximum (FWHM) is achieved. A route to demonstrating long-term stability of 2x10-14 (τ=100sec) whilst maintaining -123 dBc/Hz (1Hz offset) close-to-carrier phase noise is provided. The clock’s performance has not been measured as the laser and microwave locking loops are not fully functional.","abstract_has_math":false,"creators":["Kenny, Stuart Edward"],"institution":"University of York","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Everard, Jeremy Kenneth Arthur","Bale, Simon Jonathan"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-12","date_published":"2023-12","updated_at":"2026-11-18T23:27:10Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/R512151/1"],"render_values":[{"text":"EP/R512151/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["000000020142613X"],"render_values":[{"text":"0000-0002-0142-613X","href":"https://orcid.org/0000-0002-0142-613X","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/35200/1/Kenny_204046842.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A35200","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Everard, Jeremy Kenneth Arthur","Bale, Simon Jonathan"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC","Leonardo MW Ltd."]},{"key":"dc:creator","label":"Author","values":["Kenny, Stuart Edward"]},{"key":"person:identifier.orcid","label":"ORCID","values":["000000020142613X"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-12"]},{"key":"dc:date.issued","label":"Date","values":["2023-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Physics, Engineering and Technology (York)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of York"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/35200/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] R. Descartes, Renati Descartes Principia philosophiae. apud [et per] Ludovicum Elzevirium, 1644. [2] A. Janiak, ‘Space, atoms and mathematical divisibility in Newton’, Stud. Hist. Philos. Sci., vol. 31, no. 2, pp. 203–230, Jun. 2000. [3] M. A. Lombardi, ‘The evolution of time measurement, part 3: atomic clocks [Recalibration]’, IEEE Instrum. Meas. Mag., vol. 14, no. 6, pp. 46–49, Dec. 2011. [4] I. I. Rabi, J. R. Zacharias, S. Millman, and P. Kusch, ‘A New Method of Measuring Nuclear Magnetic Moment’, Phys. Rev., vol. 53, no. 4, pp. 318–318, Feb. 1938. [5] D. B. Sullivan, ‘Time and frequency measurement at NIST: the first 100 years’, in Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218), 2001, pp. 4–17. [6] L. Essen and J. V. L. Parry, ‘An Atomic Standard of Frequency and Time Interval: A Cæsium Resonator’, Nature, vol. 176, p. 280, Aug. 1955. [7] W. Markowitz, R. G. Hall, L. Essen, and J. V. Parry, ‘Frequency of Cesium in Terms of Ephemeris Time’, Phys. Rev. Lett., vol. 1, pp. 105–107, Aug. 1958. [8] ‘Definition of the second’, BIPM. [Online]. Available: https://www.bipm.org/en/publications/si-brochure/second.html. [Accessed: 23-Jul-2018]. [9] G. Busca, L.-G. Bernier, and P. Rochat, ‘Active hydrogen maser atomic frequency standard’, 5838206A, 17-Nov-1998. [10] M. A. Humphrey, ‘Precision measurements with atomic hydrogen masers’, PhD, Harvard University, 2003. [11] T. Burtichelov, ‘Developing an Ultra-Low Phase Noise Atomic Frequency Reference using Coherent Population Trapping (CPT) in Rubidium’, PhD, University of York, 2017. [12] M. Arditi, ‘Gas Cell “Atomic Clocks” Using Buffer Gases and Optical Orientation’, in 12th Annual Symposium on Frequency Control, 1958, pp. 606–622. [13] C. Cohen-Tannoudji and A. Kastler, ‘Optical Pumping’, in Progress in Optics, vol. 5, E. Wolf, Ed. Elsevier, 1966, pp. 1–81. [14] W. Happer, ‘Optical Pumping’, Reviews of Modern Physics, vol. 44, no. April 1972, Apr. 1972. [15] E. Arimondo, M. Inguscio, and P. Violino, ‘Experimental determinations of the hyperfine structure in the alkali atoms’, Rev. Mod. Phys., vol. 49, no. 1, pp. 31–75, Jan. 1977. [16] ‘PRS10 Rubidium Frequency Standard Operation and Service Manual’, Stanford Research Systems. [17] D. Castelvecchi, ‘100 Years Ago, a Quantum Experiment Explained Why We Don’t Fall through Our Chairs’, SA Space & Physics, vol. 5, Apr-2022. [18] D. B. Sullivan et al., ‘Primary Atomic Frequency Standards at NIST’, J. Res. Natl. Inst. Stand. Technol., vol. 106, no. 1, pp. 47–63, Feb. 2001. [19] R. E. Beehler, R. C. Mockler, and J. M. Richardson, ‘Cesium Beam Atomic Time and Frequency Standards’, Metrologia, vol. 1, no. 3, p. 114, Jul. 1965. [20] B. J. Dalton and P. L. Knight, ‘The effects of laser field fluctuations on coherent population trapping’, J. Phys. B At. Mol. Opt. Phys., vol. 15, no. 21, p. 3997, 1982. [21] The Editors of Encyclopædia Britannica, ‘D-lines’, Encyclopædia Britannica. Encyclopædia Britannica, inc., 20-Jul-1998. [22] E. Arimondo, ‘Coherent Population Trapping in Laser Spectroscopy’, in Progress in Optics, vol. 35, E. Wolf, Ed. Elsevier, 1996, pp. 257–354. [23] S. Goka, ‘85Rb D1-line CPT atomic clock with low power consumption’, in 2009 IEEE International Frequency Control Symposium Joint with the 22nd European Frequency and Time forum, 2009, pp. 578–581. [24] M. Arditi and T. R. Carver, ‘Pressure, Light, and Temperature Shifts in Optical Detection of 0-0 Hyperfine Resonance of Alkali Metals’, Phys. Rev., vol. 124, no. 3, pp. 800–809, Nov. 1961. [25] N. F. Ramsey, ‘A New Molecular Beam Resonance Method’, Phys. Rev., vol. 76, no. 7, pp. 996–996, Oct. 1949. [26] J. Guéna et al., ‘Demonstration of a dual alkali Rb/Cs fountain clock’, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 57, no. 3, pp. 647–653, Mar. 2010. [27] R. Wynands and S. Weyers, ‘Atomic fountain clocks’, Metrologia, vol. 42, no. 3, p. S64, Jun. 2005. [28] G. J. Dick, J. D. Prestage, C. A. Greenhall, and L. Maleki, ‘Local oscillator introduced degradation of medium-term stability in passive atomic frequency standards’, in Proceedings of the 22th Annual Precise Time and Time Interval Systems and Applications Meeting December 4 - 6, 1990 Sheraton Premiere Hotel Vienna, Virginia, Vienna, Virginia, 1990, pp. 487–508. [29] F. G. Ascarrunz et al., ‘A Portable Cold 87Rb Atomic Clock with Frequency Instability at One Day in the 10−15Range’, in 2018 IEEE International Frequency Control Symposium (IFCS), 2018, pp. 1–3. [30] ‘SpectraDynamics cRb- Clock - a portable cold Rubidium microwave atomic clock’, SDI. [Online]. Available: https://spectradynamics.com/products/crb-clock/. [Accessed: 13-Aug-2020]. [31] ‘Portable Microwave Cold Atomic Clock - Dimensions’. [Online]. Available: https://app.dimensions.ai/details/grant/grant.4382146. [Accessed: 21-May-2024]. [32] S. Micalizio, C. E. Calosso, A. Godone, and F. Levi, ‘Metrological characterization of the pulsed Rb clock with optical detection’, Metrologia, vol. 49, no. 4, p. 425, May 2012. [33] T. Rosenband et al., ‘Frequency ratio of Al+ and Hg+ single-ion optical clocks; metrology at the 17th decimal place’, Science, vol. 319, no. 5871, pp. 1808–1812, Mar. 2008. [34] D. J. Jones et al., ‘Carrier-envelope phase control of femtosecond mode-locked lasers and direct optical frequency synthesis’, Science, vol. 288, no. 5466, pp. 635–640, Apr. 2000. [35] M. Vengalattore, ‘Viewpoint: A Boost in Precision for Optical Atomic Clocks’, Physics, vol. 11, no. 22, 05-Mar-2018. [36] N. Poli, C. W. Oates, P. Gill, and G. M. Tino, ‘Optical atomic clocks’, arXiv [physics.atom-ph], 10-Jan-2014. [37] N. Ohtsubo, Y. Li, K. Matsubara, T. Ido, and K. Hayasaka, ‘Frequency measurement of the clock transition of an indium ion sympathetically-cooled in a linear trap’, Opt. Express, vol. 25, no. 10, pp. 11725–11735, May 2017. [38] S. M. Brewer et al., ‘Measurements ofAl+27andMg+25magnetic constants for improved ion-clock accuracy’, Phys. Rev. A, vol. 100, no. 1, Jul. 2019. [39] M. Piotrowski, J. Scarabel, M. Lobino, E. Streed, and S. Gensemer, ‘Studies of thorium and ytterbium ion trap loading from laser ablation for gravity monitoring with nuclear clocks’, OSA Contin., vol. 3, no. 8, p. 2210, Aug. 2020. [40] J. Yao et al., ‘Optical-Clock-Based Time Scale’, Phys Rev Appl, vol. 12, no. 4, 2019. [41] M. Gellesch et al., ‘Transportable optical atomic clocks for use in out-of-the-lab environments’, Advanced Optical Technologies, vol. 9, no. 5, pp. 313–325, Oct. 2020. [42] M. Aldous et al., ‘Route to a Portable Optical Clock’, in 2018 IEEE International Frequency Control Symposium (IFCS), 2018, pp. 1–3. [43] D. W. Allan, ‘Statistics of atomic frequency standards’, Proc. IEEE, vol. 54, no. 2, pp. 221–230, Feb. 1966. [44] ‘1139-1999 - IEEE Standard Definitions of Physical Quantities for Fundamental Frequency and Time Metrology-Random Instabilities’, IEEE Std 1139-1999. IEEE, pp. 1–40, 21-Jul-1999. [45] M. Weiss and K. Shenoi, ‘TDEV Then and Now’, in ISTF 2015, Edinburgh, 2015. [46] T. Mai, ‘Technology readiness level’, NASA, 2015. [Online]. Available: http://www.nasa.gov/directorates/heo/scan/engineering/technology/txt_accordion1.html. [Accessed: 11-Sep-2018]. [47] J. Everard, T. Burtichelov, and K. Ng, ‘Ultralow Phase Noise 10-MHz Crystal Oscillators’, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 66, no. 1, pp. 181–191, Jan. 2019. [48] D. B. Sullivan, D. W. Allan, D. A. Howe, and F. L. Walls, ‘Characterisation of Clocks and Oscillators, NIST technical note 1337’, NIST, Mar. 1990. [49] ‘Allan Variance’, Iowa State University. [Online]. Available: http://home.engineering.iastate.edu/~shermanp/AERE432/lectures/Rate%20Gyros/Allan%20variance.pdf. [Accessed: 11-Sep-2018]. [50] J. Kitching, ‘Chip-scale atomic devices’, Applied Physics Reviews, vol. 5, no. 3, p. 031302, Sep. 2018. [51] M. Gharavipour, ‘Ramsey Spectroscopy in a Rubidium Vapor Cell and Realization of an Ultra-Stable Atomic Clock’, PhD, UNIVERSITÉ DE NEUCHÂTEL, 2018. [52] R. M. Eisberg and R. Resnick, Quantum Physics of Atoms, Molecules, Solids, Nuclei, and Particles. Wiley, 1985. [53] R. C. Pooser, A. M. Marino, V. Boyer, K. M. Jones, and P. D. Lett, ‘Quantum correlated light beams from non-degenerate four-wave mixing in an atomic vapor: the D1 and D2 lines of 85Rb and 87Rb’, Opt. Express, vol. 17, no. 19, pp. 16722–16730, Sep. 2009. [54] W. H. Wollaston, ‘XII. A method of examining refractive and dispersive powers, by prismatic reflection’, Philosophical Transactions of the Royal Society of London, vol. 92, pp. 365–380, Jan. 1997. [55] D. A. Steck, ‘Rubidium 85 D Line Data’, no. 2.14. 23-Dec-2010. [56] P. Zeeman, ‘XXXIII. Doublets and triplets in the spectrum produced by external magnetic forces.—(II.)’, The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science, vol. 44, no. 268, pp. 255–259, Sep. 1897. [57] R. Shankar, Principles of Quantum Mechanics. Springer US, 1995. [58] T. Burtichelov, ‘Design and Construction of a Rubidium Atomic Clock’, University of York, Jun. 2012. [59] T. Zanon, S. Guerandel, E. de Clercq, D. Holleville, N. Dimarcq, and A. Clairon, ‘High contrast Ramsey fringes with coherent-population-trapping pulses in a double lambda atomic system’, Phys. Rev. Lett., vol. 94, no. 19, p. 193002, May 2005. [60] B. Gao, ‘Effects of Zeeman degeneracy on the steady-state properties of an atom interacting with a near-resonant laser field: Analytic results’, Phys. Rev. A, vol. 48, no. 3, pp. 2443–2448, Sep. 1993. [61] N. F. Ramsey, ‘Experiments with separated oscillatory fields and hydrogen masers’, Rev. Mod. Phys., vol. 63, no. 3, pp. 541–552, Jul. 1990. [62] N. F. Ramsey, ‘A molecular beam resonance method with separated oscillating fields’, Physical Review, vol. 78, no. 6, Jun. 1950. [63] T. Scholtes, S. Woetzel, R. IJsselsteijn, V. Schultze, and H.-G. Meyer, ‘Intrinsic relaxation rates of polarized Cs vapor in miniaturized cells’, Appl. Phys. B, vol. 117, no. 1, pp. 211–218, Oct. 2014. [64] T. Lindvall, M. Merimaa, I. Tittonen, and E. Ikonen, ‘ALL-OPTICAL ATOMIC CLOCK BASED ON DARK STATES OF 85Rb’, in Frequency Standards and Metrology, WORLD SCIENTIFIC, 2002, pp. 183–190. [65] J. Vanier and C. Audoin, The Quantum Physics of Atomic Frequency Standards. A. Hilger, 1989. [66] J. Vanier, J.-F. Simard, and J.-S. Boulanger, ‘Relaxation and frequency shifts in the ground state of Rb85’, Phys. Rev. A Gen. Phys., vol. 9, no. 3, pp. 1031–1040, Mar. 1974. [67] Y. Ito, D. Sato, K. Kamada, and T. Kobayashi, ‘Optimal densities of alkali metal atoms in an optically pumped K-Rb hybrid atomic magnetometer considering the spatial distribution of spin polarization’, Opt. Express, vol. 24, no. 14, pp. 15391–15402, Jul. 2016. [68] K. Ishikawa and T. Yabuzaki, ‘Diffusion coefficient and sublevel coherence of Rb atoms in N2 buffer gas’, Phys. Rev. A, vol. 62, no. 6, p. 065401, Nov. 2000. [69] O. Firstenberg, M. Shuker, A. Ben-Kish, D. R. Fredkin, N. Davidson, and A. Ron, ‘Theory of Dicke narrowing in coherent population trapping’, arXiv [quant-ph], 02-Jan-2007. [70] S. Micalizio, A. Godone, F. Levi, and J. Vanier, ‘Spin-exchange frequency shift in alkali-metal-vapor cell frequency standards’, Phys. Rev. A, vol. 73, no. 3, p. 033414, Mar. 2006. [71] J.-H. Liu et al., ‘The polarization and the fundamental sensitivity of 39K (133Cs)-85Rb-4He hybrid optical pumping spin exchange relaxation free atomic magnetometers’, Sci. Rep., vol. 7, no. 1, p. 6776, Jul. 2017. [72] H. Shang et al., ‘Design of a Measuring Device and Experimental Study into the Relationship between Temperature and the Density of Alkali Metal-Vapor’, Photonics, vol. 10, no. 2, p. 112, Jan. 2023. [73] C. B. Alcock, V. P. Itkin, and M. K. Horrigan, ‘Vapour Pressure Equations for the Metallic Elements: 298–2500K’, Can. Metall. Q., vol. 23, no. 3, pp. 309–313, Jul. 1984. [74] F. Levi, C. E. Calosso, A. Godone, and S. Micalizio, ‘Pulsed optically pumped Rb clock: A high stability vapor cell frequency standard’, in 2013 Joint European Frequency and Time Forum International Frequency Control Symposium (EFTF/IFC), 2013, pp. 599–605. [75] R. Li, L. Zhou, J. Wang, and M. Zhan, ‘Measurement of the quadratic Zeeman shift of 85Rb hyperfine sublevels using stimulated Raman transitions’, arXiv [physics.atom-ph], 01-Dec-2008. [76] A. Godone, S. Micalizio, C. E. Calosso, and F. Levi, ‘The pulsed rubidium clock’, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 3, pp. 525–529, Mar. 2006. [77] A. Godone, S. Micalizio, F. Levi, and C. Calosso, ‘Microwave cavities for vapor cell frequency standards’, Rev. Sci. Instrum., vol. 82, no. 7, p. 074703, Jul. 2011. [78] T. Burtichelov and J. Everard, ‘Latest results in the development of an ultra-low phase noise Rb CPT vapour cell atomic clock’, in 2017 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFC), 2017, pp. 837–841. [79] S. Micalizio, A. Godone, C. Calosso, F. Levi, C. Affolderbach, and F. Gruet, ‘Pulsed optically pumped rubidium clock with high frequency-stability performance’, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 59, no. 3, pp. 457–462, Mar. 2012. [80] Q. Shen, H. Lin, J. Deng, and Y. Wang, ‘Pulsed optically pumped atomic clock with a medium- to long-term frequency stability of 10−15’, Rev. Sci. Instrum., vol. 91, no. 4, p. 045114, Apr. 2020. [81] Q. Su-Ping, Z. Yi, and G. Si-Hong, ‘Dependence of the 85Rb coherent population trapping resonance characteristic on the pressure of N2 buffer gas’, Chin. Physics B, vol. 22, no. 9, p. 099501, Sep. 2013. [82] P. Yun et al., ‘High-Performance Coherent Population Trapping Clock with Polarization Modulation’, Phys. Rev. Applied, vol. 7, no. 1, p. 014018, Jan. 2017. [83] M. Stähler et al., ‘Coherent population trapping resonances in thermal (85)Rb vapor: D(1) versus D(2) line excitation’, Opt. Lett., vol. 27, no. 16, pp. 1472–1474, Aug. 2002. [84] V. N. Baryshev, M. S. Aleynikov, G. V. Osipenko, and I. Yu. Blinov, ‘Technique of pulsed optical pumping and pulsed excitation of microwave resonances using the Ramsey scheme in a 87Rb cell with a buffer gas’, Quantum Electron., vol. 48, no. 5, p. 443, May 2018. [85] V. Baryshev, M. Aleynikov, G. Osipenko, V. Epikhin, I. Blinov, and S. Donchenko, ‘Pulsed Optically Pumped Rb Clock: Laboratory Prototype at VNIIFTRI’, in Proc. of 2016 IEEE Int. Frequency Control Symposium, Roosevelt Hotel, New Orleans, Louisiana, USA, pp. 205–208. [86] M. A. Kasevich, E. Riis, S. Chu, and R. G. DeVoe, ‘RF spectroscopy in an atomic fountain’, Phys. Rev. Lett., vol. 63, no. 6, pp. 612–615, Aug. 1989. [87] D. M. Pozar, Microwave Engineering. John Wiley & Sons, 2011. [88] S. Ramo, J. R. Whinnery, and T. Van Duzer, Fields and waves in communication electronics. John Wiley & Sons, 1965. [89] H. Eklund, A. Roos, and S. T. Eng, ‘Rotation of laser beam polarization in acousto-optic devices’, Opt. Quantum Electron., vol. 7, no. 2, pp. 73–79, Mar. 1975. [90] R. Paschotta, ‘Acousto-optic Modulators’, RP Photonics Consulting GmbH, 05-Jul-2019. [Online]. Available: https://www.rp-photonics.com/acousto_optic_modulators.html. [Accessed: 19-Oct-2019]. [91] W. J. Schwenger and J. M. Higbie, ‘High-speed acousto-optic shutter with no optical frequency shift’, Rev. Sci. Instrum., vol. 83, no. 8, p. 083110, Aug. 2012. [92] M. Egan, ‘The 20-Bit DAC Is the Easiest Part of a 1-ppm-Accurate Precision Voltage Source | Analog Devices’, Analog Dialogue, vol. 44, no. 4, pp. 1–4, Apr-2010. [93] R. Y. Richard Lyons, ‘Reducing ADC Quantization Noise’, Microwaves & Radio Frequency, 17-Jun-2005. [Online]. Available: http://www.mwrf.com/components/reducing-adc-quantization-noise. [Accessed: 16-Apr-2018]. [94] SiliconLabs, ‘AN118 - Improving ADC resolution by oversampling and averaging’. Jul-2013. [95] S. Micalizio, F. Levi, C. E. Calosso, M. Gozzelino, and A. Godone, ‘A pulsed-Laser Rb atomic frequency standard for GNSS applications’, GPS Solutions, vol. 25, no. 3, p. 94, Apr. 2021. [96] S. Schmidt-Eberle, ‘Phase and frequency locking of diode lasers’, TOPTICA Photonics AG, Apr. 2021. [97] M. Gozzelino et al., ‘Realization of a pulsed optically pumped Rb clock with a frequency stability below [Formula: see text]’, Sci. Rep., vol. 13, no. 1, p. 12974, Aug. 2023. [98] S. Micalizio, C. E. Calosso, F. Levi, and A. Godone, ‘Ramsey-fringe shape in an alkali-metal vapor cell with buffer gas’, Phys. Rev. A, vol. 88, no. 3, p. 033401, Sep. 2013."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/R512151/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/35200/1/Kenny_204046842.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Since the first ammonia clock in 1949, atomic clocks have been developed to provide improved frequency stability as well as miniature designs capable of being worn on the wrist. With a small number of notable exceptions, most research activity has been directed at improving clock accuracy without regard to power or size, or with very constrained power and volume goals. A design that offers improved frequency stability, within a moderate volume, and that can be used whilst moving, would prove a widely useful reference in laboratory, communication, and navigation applications. To fill this gap, this thesis uses simplified apparatus to achieve the Pulsed Optical Pumping (POP) technique; proves the viability of an alternative to a conventional cylindrical cavity; develops a higher-resolution Digital to Analog Convertor (DAC) than anything commercially available; and does so in a way that can fit within the volume of a shoebox. Limiting factors to the performance of a 85Rb cell are calculated, and a central Ramsey fringe with 100 Hz Full Width at Half Maximum (FWHM) is achieved. A route to demonstrating long-term stability of 2x10-14 (τ=100sec) whilst maintaining -123 dBc/Hz (1Hz offset) close-to-carrier phase noise is provided. The clock’s performance has not been measured as the laser and microwave locking loops are not fully functional."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of a Pulsed Optical Pumped Rubidium Clock"]}]}],"canonical_facts":{"dc:contributor.advisor":["Everard, Jeremy Kenneth Arthur","Bale, Simon Jonathan"],"dc:contributor.sponsor":["EPSRC","Leonardo MW Ltd."],"dc:creator":["Kenny, Stuart Edward"],"dc:date":["2023-12"],"dc:date.issued":["2023-12"],"dc:description.abstract":["Since the first ammonia clock in 1949, atomic clocks have been developed to provide improved frequency stability as well as miniature designs capable of being worn on the wrist. With a small number of notable exceptions, most research activity has been directed at improving clock accuracy without regard to power or size, or with very constrained power and volume goals. A design that offers improved frequency stability, within a moderate volume, and that can be used whilst moving, would prove a widely useful reference in laboratory, communication, and navigation applications. To fill this gap, this thesis uses simplified apparatus to achieve the Pulsed Optical Pumping (POP) technique; proves the viability of an alternative to a conventional cylindrical cavity; develops a higher-resolution Digital to Analog Convertor (DAC) than anything commercially available; and does so in a way that can fit within the volume of a shoebox. Limiting factors to the performance of a 85Rb cell are calculated, and a central Ramsey fringe with 100 Hz Full Width at Half Maximum (FWHM) is achieved. A route to demonstrating long-term stability of 2x10-14 (τ=100sec) whilst maintaining -123 dBc/Hz (1Hz offset) close-to-carrier phase noise is provided. The clock’s performance has not been measured as the laser and microwave locking loops are not fully functional."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/R512151/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/35200/1/Kenny_204046842.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Physics, Engineering and Technology (York)"],"dc:publisher.institution":["University of York"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/35200/"],"dc:relation.references":["[1] R. Descartes, Renati Descartes Principia philosophiae. apud [et per] Ludovicum Elzevirium, 1644. [2] A. Janiak, ‘Space, atoms and mathematical divisibility in Newton’, Stud. Hist. Philos. Sci., vol. 31, no. 2, pp. 203–230, Jun. 2000. [3] M. A. Lombardi, ‘The evolution of time measurement, part 3: atomic clocks [Recalibration]’, IEEE Instrum. Meas. Mag., vol. 14, no. 6, pp. 46–49, Dec. 2011. [4] I. I. Rabi, J. R. Zacharias, S. Millman, and P. Kusch, ‘A New Method of Measuring Nuclear Magnetic Moment’, Phys. Rev., vol. 53, no. 4, pp. 318–318, Feb. 1938. [5] D. B. Sullivan, ‘Time and frequency measurement at NIST: the first 100 years’, in Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218), 2001, pp. 4–17. [6] L. Essen and J. V. L. Parry, ‘An Atomic Standard of Frequency and Time Interval: A Cæsium Resonator’, Nature, vol. 176, p. 280, Aug. 1955. [7] W. Markowitz, R. G. Hall, L. Essen, and J. V. Parry, ‘Frequency of Cesium in Terms of Ephemeris Time’, Phys. Rev. Lett., vol. 1, pp. 105–107, Aug. 1958. [8] ‘Definition of the second’, BIPM. [Online]. Available: https://www.bipm.org/en/publications/si-brochure/second.html. [Accessed: 23-Jul-2018]. [9] G. Busca, L.-G. Bernier, and P. Rochat, ‘Active hydrogen maser atomic frequency standard’, 5838206A, 17-Nov-1998. [10] M. A. Humphrey, ‘Precision measurements with atomic hydrogen masers’, PhD, Harvard University, 2003. [11] T. Burtichelov, ‘Developing an Ultra-Low Phase Noise Atomic Frequency Reference using Coherent Population Trapping (CPT) in Rubidium’, PhD, University of York, 2017. [12] M. Arditi, ‘Gas Cell “Atomic Clocks” Using Buffer Gases and Optical Orientation’, in 12th Annual Symposium on Frequency Control, 1958, pp. 606–622. [13] C. Cohen-Tannoudji and A. Kastler, ‘Optical Pumping’, in Progress in Optics, vol. 5, E. Wolf, Ed. Elsevier, 1966, pp. 1–81. [14] W. Happer, ‘Optical Pumping’, Reviews of Modern Physics, vol. 44, no. April 1972, Apr. 1972. [15] E. Arimondo, M. Inguscio, and P. Violino, ‘Experimental determinations of the hyperfine structure in the alkali atoms’, Rev. Mod. Phys., vol. 49, no. 1, pp. 31–75, Jan. 1977. [16] ‘PRS10 Rubidium Frequency Standard Operation and Service Manual’, Stanford Research Systems. [17] D. Castelvecchi, ‘100 Years Ago, a Quantum Experiment Explained Why We Don’t Fall through Our Chairs’, SA Space & Physics, vol. 5, Apr-2022. [18] D. B. Sullivan et al., ‘Primary Atomic Frequency Standards at NIST’, J. Res. Natl. Inst. Stand. Technol., vol. 106, no. 1, pp. 47–63, Feb. 2001. [19] R. E. Beehler, R. C. Mockler, and J. M. Richardson, ‘Cesium Beam Atomic Time and Frequency Standards’, Metrologia, vol. 1, no. 3, p. 114, Jul. 1965. [20] B. J. Dalton and P. L. Knight, ‘The effects of laser field fluctuations on coherent population trapping’, J. Phys. B At. Mol. Opt. Phys., vol. 15, no. 21, p. 3997, 1982. [21] The Editors of Encyclopædia Britannica, ‘D-lines’, Encyclopædia Britannica. Encyclopædia Britannica, inc., 20-Jul-1998. [22] E. Arimondo, ‘Coherent Population Trapping in Laser Spectroscopy’, in Progress in Optics, vol. 35, E. Wolf, Ed. Elsevier, 1996, pp. 257–354. [23] S. Goka, ‘85Rb D1-line CPT atomic clock with low power consumption’, in 2009 IEEE International Frequency Control Symposium Joint with the 22nd European Frequency and Time forum, 2009, pp. 578–581. [24] M. Arditi and T. R. Carver, ‘Pressure, Light, and Temperature Shifts in Optical Detection of 0-0 Hyperfine Resonance of Alkali Metals’, Phys. Rev., vol. 124, no. 3, pp. 800–809, Nov. 1961. [25] N. F. Ramsey, ‘A New Molecular Beam Resonance Method’, Phys. Rev., vol. 76, no. 7, pp. 996–996, Oct. 1949. [26] J. Guéna et al., ‘Demonstration of a dual alkali Rb/Cs fountain clock’, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 57, no. 3, pp. 647–653, Mar. 2010. [27] R. Wynands and S. Weyers, ‘Atomic fountain clocks’, Metrologia, vol. 42, no. 3, p. S64, Jun. 2005. [28] G. J. Dick, J. D. Prestage, C. A. Greenhall, and L. Maleki, ‘Local oscillator introduced degradation of medium-term stability in passive atomic frequency standards’, in Proceedings of the 22th Annual Precise Time and Time Interval Systems and Applications Meeting December 4 - 6, 1990 Sheraton Premiere Hotel Vienna, Virginia, Vienna, Virginia, 1990, pp. 487–508. [29] F. G. Ascarrunz et al., ‘A Portable Cold 87Rb Atomic Clock with Frequency Instability at One Day in the 10−15Range’, in 2018 IEEE International Frequency Control Symposium (IFCS), 2018, pp. 1–3. [30] ‘SpectraDynamics cRb- Clock - a portable cold Rubidium microwave atomic clock’, SDI. [Online]. Available: https://spectradynamics.com/products/crb-clock/. [Accessed: 13-Aug-2020]. [31] ‘Portable Microwave Cold Atomic Clock - Dimensions’. [Online]. Available: https://app.dimensions.ai/details/grant/grant.4382146. [Accessed: 21-May-2024]. [32] S. Micalizio, C. E. Calosso, A. Godone, and F. Levi, ‘Metrological characterization of the pulsed Rb clock with optical detection’, Metrologia, vol. 49, no. 4, p. 425, May 2012. [33] T. Rosenband et al., ‘Frequency ratio of Al+ and Hg+ single-ion optical clocks; metrology at the 17th decimal place’, Science, vol. 319, no. 5871, pp. 1808–1812, Mar. 2008. [34] D. J. Jones et al., ‘Carrier-envelope phase control of femtosecond mode-locked lasers and direct optical frequency synthesis’, Science, vol. 288, no. 5466, pp. 635–640, Apr. 2000. [35] M. Vengalattore, ‘Viewpoint: A Boost in Precision for Optical Atomic Clocks’, Physics, vol. 11, no. 22, 05-Mar-2018. [36] N. Poli, C. W. Oates, P. Gill, and G. M. Tino, ‘Optical atomic clocks’, arXiv [physics.atom-ph], 10-Jan-2014. [37] N. Ohtsubo, Y. Li, K. Matsubara, T. Ido, and K. Hayasaka, ‘Frequency measurement of the clock transition of an indium ion sympathetically-cooled in a linear trap’, Opt. Express, vol. 25, no. 10, pp. 11725–11735, May 2017. [38] S. M. Brewer et al., ‘Measurements ofAl+27andMg+25magnetic constants for improved ion-clock accuracy’, Phys. Rev. A, vol. 100, no. 1, Jul. 2019. [39] M. Piotrowski, J. Scarabel, M. Lobino, E. Streed, and S. Gensemer, ‘Studies of thorium and ytterbium ion trap loading from laser ablation for gravity monitoring with nuclear clocks’, OSA Contin., vol. 3, no. 8, p. 2210, Aug. 2020. [40] J. Yao et al., ‘Optical-Clock-Based Time Scale’, Phys Rev Appl, vol. 12, no. 4, 2019. [41] M. Gellesch et al., ‘Transportable optical atomic clocks for use in out-of-the-lab environments’, Advanced Optical Technologies, vol. 9, no. 5, pp. 313–325, Oct. 2020. [42] M. Aldous et al., ‘Route to a Portable Optical Clock’, in 2018 IEEE International Frequency Control Symposium (IFCS), 2018, pp. 1–3. [43] D. W. Allan, ‘Statistics of atomic frequency standards’, Proc. IEEE, vol. 54, no. 2, pp. 221–230, Feb. 1966. [44] ‘1139-1999 - IEEE Standard Definitions of Physical Quantities for Fundamental Frequency and Time Metrology-Random Instabilities’, IEEE Std 1139-1999. IEEE, pp. 1–40, 21-Jul-1999. [45] M. Weiss and K. Shenoi, ‘TDEV Then and Now’, in ISTF 2015, Edinburgh, 2015. [46] T. Mai, ‘Technology readiness level’, NASA, 2015. [Online]. Available: http://www.nasa.gov/directorates/heo/scan/engineering/technology/txt_accordion1.html. [Accessed: 11-Sep-2018]. [47] J. Everard, T. Burtichelov, and K. Ng, ‘Ultralow Phase Noise 10-MHz Crystal Oscillators’, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 66, no. 1, pp. 181–191, Jan. 2019. [48] D. B. Sullivan, D. W. Allan, D. A. Howe, and F. L. Walls, ‘Characterisation of Clocks and Oscillators, NIST technical note 1337’, NIST, Mar. 1990. [49] ‘Allan Variance’, Iowa State University. [Online]. Available: http://home.engineering.iastate.edu/~shermanp/AERE432/lectures/Rate%20Gyros/Allan%20variance.pdf. [Accessed: 11-Sep-2018]. [50] J. Kitching, ‘Chip-scale atomic devices’, Applied Physics Reviews, vol. 5, no. 3, p. 031302, Sep. 2018. [51] M. Gharavipour, ‘Ramsey Spectroscopy in a Rubidium Vapor Cell and Realization of an Ultra-Stable Atomic Clock’, PhD, UNIVERSITÉ DE NEUCHÂTEL, 2018. [52] R. M. Eisberg and R. Resnick, Quantum Physics of Atoms, Molecules, Solids, Nuclei, and Particles. Wiley, 1985. [53] R. C. Pooser, A. M. Marino, V. Boyer, K. M. Jones, and P. D. Lett, ‘Quantum correlated light beams from non-degenerate four-wave mixing in an atomic vapor: the D1 and D2 lines of 85Rb and 87Rb’, Opt. Express, vol. 17, no. 19, pp. 16722–16730, Sep. 2009. [54] W. H. Wollaston, ‘XII. A method of examining refractive and dispersive powers, by prismatic reflection’, Philosophical Transactions of the Royal Society of London, vol. 92, pp. 365–380, Jan. 1997. [55] D. A. Steck, ‘Rubidium 85 D Line Data’, no. 2.14. 23-Dec-2010. [56] P. Zeeman, ‘XXXIII. Doublets and triplets in the spectrum produced by external magnetic forces.—(II.)’, The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science, vol. 44, no. 268, pp. 255–259, Sep. 1897. [57] R. Shankar, Principles of Quantum Mechanics. Springer US, 1995. [58] T. Burtichelov, ‘Design and Construction of a Rubidium Atomic Clock’, University of York, Jun. 2012. [59] T. Zanon, S. Guerandel, E. de Clercq, D. Holleville, N. Dimarcq, and A. Clairon, ‘High contrast Ramsey fringes with coherent-population-trapping pulses in a double lambda atomic system’, Phys. Rev. Lett., vol. 94, no. 19, p. 193002, May 2005. [60] B. Gao, ‘Effects of Zeeman degeneracy on the steady-state properties of an atom interacting with a near-resonant laser field: Analytic results’, Phys. Rev. A, vol. 48, no. 3, pp. 2443–2448, Sep. 1993. [61] N. F. Ramsey, ‘Experiments with separated oscillatory fields and hydrogen masers’, Rev. Mod. Phys., vol. 63, no. 3, pp. 541–552, Jul. 1990. [62] N. F. Ramsey, ‘A molecular beam resonance method with separated oscillating fields’, Physical Review, vol. 78, no. 6, Jun. 1950. [63] T. Scholtes, S. Woetzel, R. IJsselsteijn, V. Schultze, and H.-G. Meyer, ‘Intrinsic relaxation rates of polarized Cs vapor in miniaturized cells’, Appl. Phys. B, vol. 117, no. 1, pp. 211–218, Oct. 2014. [64] T. Lindvall, M. Merimaa, I. Tittonen, and E. Ikonen, ‘ALL-OPTICAL ATOMIC CLOCK BASED ON DARK STATES OF 85Rb’, in Frequency Standards and Metrology, WORLD SCIENTIFIC, 2002, pp. 183–190. [65] J. Vanier and C. Audoin, The Quantum Physics of Atomic Frequency Standards. A. Hilger, 1989. [66] J. Vanier, J.-F. Simard, and J.-S. Boulanger, ‘Relaxation and frequency shifts in the ground state of Rb85’, Phys. Rev. A Gen. Phys., vol. 9, no. 3, pp. 1031–1040, Mar. 1974. [67] Y. Ito, D. Sato, K. Kamada, and T. Kobayashi, ‘Optimal densities of alkali metal atoms in an optically pumped K-Rb hybrid atomic magnetometer considering the spatial distribution of spin polarization’, Opt. Express, vol. 24, no. 14, pp. 15391–15402, Jul. 2016. [68] K. Ishikawa and T. Yabuzaki, ‘Diffusion coefficient and sublevel coherence of Rb atoms in N2 buffer gas’, Phys. Rev. A, vol. 62, no. 6, p. 065401, Nov. 2000. [69] O. Firstenberg, M. Shuker, A. Ben-Kish, D. R. Fredkin, N. Davidson, and A. Ron, ‘Theory of Dicke narrowing in coherent population trapping’, arXiv [quant-ph], 02-Jan-2007. [70] S. Micalizio, A. Godone, F. Levi, and J. Vanier, ‘Spin-exchange frequency shift in alkali-metal-vapor cell frequency standards’, Phys. Rev. A, vol. 73, no. 3, p. 033414, Mar. 2006. [71] J.-H. Liu et al., ‘The polarization and the fundamental sensitivity of 39K (133Cs)-85Rb-4He hybrid optical pumping spin exchange relaxation free atomic magnetometers’, Sci. Rep., vol. 7, no. 1, p. 6776, Jul. 2017. [72] H. Shang et al., ‘Design of a Measuring Device and Experimental Study into the Relationship between Temperature and the Density of Alkali Metal-Vapor’, Photonics, vol. 10, no. 2, p. 112, Jan. 2023. [73] C. B. Alcock, V. P. Itkin, and M. K. Horrigan, ‘Vapour Pressure Equations for the Metallic Elements: 298–2500K’, Can. Metall. Q., vol. 23, no. 3, pp. 309–313, Jul. 1984. [74] F. Levi, C. E. Calosso, A. Godone, and S. Micalizio, ‘Pulsed optically pumped Rb clock: A high stability vapor cell frequency standard’, in 2013 Joint European Frequency and Time Forum International Frequency Control Symposium (EFTF/IFC), 2013, pp. 599–605. [75] R. Li, L. Zhou, J. Wang, and M. Zhan, ‘Measurement of the quadratic Zeeman shift of 85Rb hyperfine sublevels using stimulated Raman transitions’, arXiv [physics.atom-ph], 01-Dec-2008. [76] A. Godone, S. Micalizio, C. E. Calosso, and F. Levi, ‘The pulsed rubidium clock’, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 3, pp. 525–529, Mar. 2006. [77] A. Godone, S. Micalizio, F. Levi, and C. Calosso, ‘Microwave cavities for vapor cell frequency standards’, Rev. Sci. Instrum., vol. 82, no. 7, p. 074703, Jul. 2011. [78] T. Burtichelov and J. Everard, ‘Latest results in the development of an ultra-low phase noise Rb CPT vapour cell atomic clock’, in 2017 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFC), 2017, pp. 837–841. [79] S. Micalizio, A. Godone, C. Calosso, F. Levi, C. Affolderbach, and F. Gruet, ‘Pulsed optically pumped rubidium clock with high frequency-stability performance’, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 59, no. 3, pp. 457–462, Mar. 2012. [80] Q. Shen, H. Lin, J. Deng, and Y. Wang, ‘Pulsed optically pumped atomic clock with a medium- to long-term frequency stability of 10−15’, Rev. Sci. Instrum., vol. 91, no. 4, p. 045114, Apr. 2020. [81] Q. Su-Ping, Z. Yi, and G. Si-Hong, ‘Dependence of the 85Rb coherent population trapping resonance characteristic on the pressure of N2 buffer gas’, Chin. Physics B, vol. 22, no. 9, p. 099501, Sep. 2013. [82] P. Yun et al., ‘High-Performance Coherent Population Trapping Clock with Polarization Modulation’, Phys. Rev. Applied, vol. 7, no. 1, p. 014018, Jan. 2017. [83] M. Stähler et al., ‘Coherent population trapping resonances in thermal (85)Rb vapor: D(1) versus D(2) line excitation’, Opt. Lett., vol. 27, no. 16, pp. 1472–1474, Aug. 2002. [84] V. N. Baryshev, M. S. Aleynikov, G. V. Osipenko, and I. Yu. Blinov, ‘Technique of pulsed optical pumping and pulsed excitation of microwave resonances using the Ramsey scheme in a 87Rb cell with a buffer gas’, Quantum Electron., vol. 48, no. 5, p. 443, May 2018. [85] V. Baryshev, M. Aleynikov, G. Osipenko, V. Epikhin, I. Blinov, and S. Donchenko, ‘Pulsed Optically Pumped Rb Clock: Laboratory Prototype at VNIIFTRI’, in Proc. of 2016 IEEE Int. Frequency Control Symposium, Roosevelt Hotel, New Orleans, Louisiana, USA, pp. 205–208. [86] M. A. Kasevich, E. Riis, S. Chu, and R. G. DeVoe, ‘RF spectroscopy in an atomic fountain’, Phys. Rev. Lett., vol. 63, no. 6, pp. 612–615, Aug. 1989. [87] D. M. Pozar, Microwave Engineering. John Wiley & Sons, 2011. [88] S. Ramo, J. R. Whinnery, and T. Van Duzer, Fields and waves in communication electronics. John Wiley & Sons, 1965. [89] H. Eklund, A. Roos, and S. T. Eng, ‘Rotation of laser beam polarization in acousto-optic devices’, Opt. Quantum Electron., vol. 7, no. 2, pp. 73–79, Mar. 1975. [90] R. Paschotta, ‘Acousto-optic Modulators’, RP Photonics Consulting GmbH, 05-Jul-2019. [Online]. Available: https://www.rp-photonics.com/acousto_optic_modulators.html. [Accessed: 19-Oct-2019]. [91] W. J. Schwenger and J. M. Higbie, ‘High-speed acousto-optic shutter with no optical frequency shift’, Rev. Sci. Instrum., vol. 83, no. 8, p. 083110, Aug. 2012. [92] M. Egan, ‘The 20-Bit DAC Is the Easiest Part of a 1-ppm-Accurate Precision Voltage Source | Analog Devices’, Analog Dialogue, vol. 44, no. 4, pp. 1–4, Apr-2010. [93] R. Y. Richard Lyons, ‘Reducing ADC Quantization Noise’, Microwaves & Radio Frequency, 17-Jun-2005. [Online]. Available: http://www.mwrf.com/components/reducing-adc-quantization-noise. [Accessed: 16-Apr-2018]. [94] SiliconLabs, ‘AN118 - Improving ADC resolution by oversampling and averaging’. Jul-2013. [95] S. Micalizio, F. Levi, C. E. Calosso, M. Gozzelino, and A. Godone, ‘A pulsed-Laser Rb atomic frequency standard for GNSS applications’, GPS Solutions, vol. 25, no. 3, p. 94, Apr. 2021. [96] S. Schmidt-Eberle, ‘Phase and frequency locking of diode lasers’, TOPTICA Photonics AG, Apr. 2021. [97] M. Gozzelino et al., ‘Realization of a pulsed optically pumped Rb clock with a frequency stability below [Formula: see text]’, Sci. Rep., vol. 13, no. 1, p. 12974, Aug. 2023. [98] S. Micalizio, C. E. Calosso, F. Levi, and A. Godone, ‘Ramsey-fringe shape in an alkali-metal vapor cell with buffer gas’, Phys. Rev. A, vol. 88, no. 3, p. 033401, Sep. 2013."],"dcterms:accessrights":["public"],"dc:title":["Development of a Pulsed Optical Pumped Rubidium Clock"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["000000020142613X"]},"updated_at":"2026-11-18T23:27:10Z"}