{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:36308"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:36308","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Monitoring and Detecting Legionella within Evaporative Cooling Towers","abstract":"Legionella pneumophila, a waterborne bacterium, is the primary cause of Legionnaires’ disease, a severe form of pneumonia contracted through the inhalation of contaminated aerosols. While this study focuses on L. pneumophila, other species, such as Legionella longbeachae, can also cause the disease, particularly in Australia and New Zealand. Cooling towers are a predominant source of Legionnaires' outbreaks, as they support the growth of both sessile and planktonic microbial communities and facilitate their aerosolisation. Therefore, microbial growth within these structures must be rigorously controlled through a variety of control measures. Currently, the efficacy of these control measures is assessed by routine monitoring of bulk water samples using culture-based methods. However, this reliance on planktonic samples combined with culture methods, typically delays remedial actions, allowing outbreaks to occur. This thesis aims to minimise the delay between the detection of Legionella and the implementation of remedial actions to prevent outbreaks. It hypothesises that biofilm samples could potentially serve as lead indicators for the rapid detection of L. pneumophila, thereby enabling timely corrective measures. Additionally, this research explores how biofilm samples enhance our understanding of interactions between biofilms, planktonic communities, and physicochemical parameters, potentially revealing key factors and trends that influence Legionella growth and lead to outbreaks. To investigate whether biofilm samples could serve as lead indicators for Legionella detection, a novel and optimised biofilm sampling technique was developed and subsequently employed. This method was complemented by independently assessed emerging detection techniques and applied across four strategically selected operational cooling towers over an 18-month period. Additionally, the impact of microbial concentration, viability, and bacterial community structure was examined using flow cytometry and 16S rRNA bacterial community analysis, respectively. This approach significantly enhanced the likelihood of identifying precursor events indicative of Legionella presence. The research revealed that biofilm samples exclusively identified L. pneumophila during the study period, with Legionella spp. found in higher concentrations in biofilms compared to bulk water. This underscores biofilms as a crucial ecological niche for Legionella spp. Although bacterial concentrations, viability, and physicochemical parameters were found to be insufficient predictors of Legionella proliferation, the composition of the bacterial community within biofilms played a pivotal role. Biofilms, while sharing a core set of taxa with bulk water, exhibited a unique community dominated by low-abundance and rare taxa that significantly influenced microbial interactions and ecological dynamics. These dynamics include the introduction of additional organic compounds and nitrogen, as well as the potential reduction of competitive bacterial populations, which can foster the growth of L. pneumophila. These findings suggest that biofilms can serve as a lead indicator for L. pneumophila, highlighting the need for more comprehensive monitoring policies, practices, and regulations. Such measures should include the assessment of biofilm samples alongside traditional planktonic samples. Prioritising biofilm samples provides a more accurate and holistic understanding of the dynamics of Legionella, revealing crucial insights into the microbial communities that foster conditions conducive to the presence of L. pneumophila. Therefore, integrating biofilm sampling into current monitoring strategies will not only enhance our understanding of Legionella proliferation but also allow for the earlier implementation of remedial actions. Ultimately, this approach is expected to reduce the risk of Legionella outbreaks, thereby safeguarding public health.","abstract_html":"Legionella pneumophila, a waterborne bacterium, is the primary cause of Legionnaires’ disease, a severe form of pneumonia contracted through the inhalation of contaminated aerosols. While this study focuses on L. pneumophila, other species, such as Legionella longbeachae, can also cause the disease, particularly in Australia and New Zealand. Cooling towers are a predominant source of Legionnaires&#x27; outbreaks, as they support the growth of both sessile and planktonic microbial communities and facilitate their aerosolisation. Therefore, microbial growth within these structures must be rigorously controlled through a variety of control measures. Currently, the efficacy of these control measures is assessed by routine monitoring of bulk water samples using culture-based methods. However, this reliance on planktonic samples combined with culture methods, typically delays remedial actions, allowing outbreaks to occur. This thesis aims to minimise the delay between the detection of Legionella and the implementation of remedial actions to prevent outbreaks. It hypothesises that biofilm samples could potentially serve as lead indicators for the rapid detection of L. pneumophila, thereby enabling timely corrective measures. Additionally, this research explores how biofilm samples enhance our understanding of interactions between biofilms, planktonic communities, and physicochemical parameters, potentially revealing key factors and trends that influence Legionella growth and lead to outbreaks. To investigate whether biofilm samples could serve as lead indicators for Legionella detection, a novel and optimised biofilm sampling technique was developed and subsequently employed. This method was complemented by independently assessed emerging detection techniques and applied across four strategically selected operational cooling towers over an 18-month period. Additionally, the impact of microbial concentration, viability, and bacterial community structure was examined using flow cytometry and 16S rRNA bacterial community analysis, respectively. This approach significantly enhanced the likelihood of identifying precursor events indicative of Legionella presence. The research revealed that biofilm samples exclusively identified L. pneumophila during the study period, with Legionella spp. found in higher concentrations in biofilms compared to bulk water. This underscores biofilms as a crucial ecological niche for Legionella spp. Although bacterial concentrations, viability, and physicochemical parameters were found to be insufficient predictors of Legionella proliferation, the composition of the bacterial community within biofilms played a pivotal role. Biofilms, while sharing a core set of taxa with bulk water, exhibited a unique community dominated by low-abundance and rare taxa that significantly influenced microbial interactions and ecological dynamics. These dynamics include the introduction of additional organic compounds and nitrogen, as well as the potential reduction of competitive bacterial populations, which can foster the growth of L. pneumophila. These findings suggest that biofilms can serve as a lead indicator for L. pneumophila, highlighting the need for more comprehensive monitoring policies, practices, and regulations. Such measures should include the assessment of biofilm samples alongside traditional planktonic samples. Prioritising biofilm samples provides a more accurate and holistic understanding of the dynamics of Legionella, revealing crucial insights into the microbial communities that foster conditions conducive to the presence of L. pneumophila. Therefore, integrating biofilm sampling into current monitoring strategies will not only enhance our understanding of Legionella proliferation but also allow for the earlier implementation of remedial actions. Ultimately, this approach is expected to reduce the risk of Legionella outbreaks, thereby safeguarding public health.","abstract_has_math":false,"creators":["KERRY, MICHAEL"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Fish, Katherine"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-05","date_published":"2024-05","updated_at":"2026-11-18T23:28:51Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/36308/1/MK%20PHD%20White%20Rose%20Submission.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A36308","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fish, Katherine"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["HSE","Sellafield"]},{"key":"dc:creator","label":"Author","values":["KERRY, MICHAEL"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-05"]},{"key":"dc:date.issued","label":"Date","values":["2024-05"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Civil and Structural Engineering (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/36308/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Abdel-Nour, M., Duncan, C., Low, D. E. and Guyard, C. (2013) 'Biofilms: the stronghold of L. pneumophila ', International journal of molecular sciences, 14(11), pp. 21660-21675. Abu Khweek, A. and Amer, A. O. (2018) 'Factors mediating environmental biofilm formation by L. pneumophila ', Frontiers in cellular and infection microbiology, 8, pp. 38. Aloraini, S., Alum, A. and Abbaszadegan, M. (2023) 'Impact of pipe material and temperature on drinking water microbiome and prevalence of Legionella, Mycobacterium, and Pseudomonas species', Microorganisms, 11(2), pp. 352. Alrahimi, J., Aldahlawi, A., Hassoubah, S., Al-Jadani, S., Alyamani, W. and Alotaibi, N. (2022) 'An Insight into the Microbiology, Epidemiology, and Host Cell Biology of L. pneumophila : A Review of Literature', Biosciences Biotechnology Research Asia, 19(3), pp. 561-577. Ames, N. J., Ranucci, A., Moriyama, B. and Wallen, G. R. (2017) 'The human microbiome and understanding the 16S rRNA gene in translational nursing science', Nursing research, 66(2), pp. 184-197. Ashbolt, N. J. (2015) 'Microbial contamination of drinking water and human health from community water systems', Current environmental health reports, 2, pp. 95-106. ASHRAE (2018) 188: In Legionellosis: Risk Management for Building Water Systems; American Society of Heating, Refrigerating and Air- Conditioning Engineers. Atlanta: ASHRAE. Azeredo, J., Azevedo, N. F., Briandet, R., Cerca, N., Coenye, T., Costa, A. R., Desvaux, M., Di Bonaventura, G., Hébraud, M., Jaglic, Z., & Kačániová, M. (2017). Critical review on biofilm methods. Critical Reviews in Microbiology, 43(3), 313-351. Barrette, I. (2019) 'Comparison of Legiolert and a conventional culture method for detection of L. pneumophila from cooling towers in Québec', Journal of AOAC International, 102(4), pp. 1235-1240. Bautista-de los Santos, Q. M., Schroeder, J. L., Sevillano-Rivera, M. C., Sungthong, R., Ijaz, U. Z., Sloan, W. T. and Pinto, A. J. (2016) 'Emerging investigators series: microbial communities in full-scale drinking water distribution systems–a meta-analysis', Environmental Science: Water Research & Technology, 2(4), pp. 631-644. Bedrina, B., Macián, S., Solís, I., Fernández-Lafuente, R., Baldrich, E. and Rodríguez, G. (2013) 'Fast immunosensing technique to detect L. pneumophila in different natural and anthropogenic environments: comparative and collaborative trials', BMC microbiology, 13, pp. 1-9. Boamah, D. K., Zhou, G., Ensminger, A. W. and O’Connor, T. J. (2017) ‘From many hosts, one accidental pathogen: the diverse protozoan hosts of Legionella’, Frontiers in Cellular and Infection Microbiology, 7, p. 477. Boczek, L. A., Tang, M., Formal, C., Lytle, D. and Ryu, H. (2021) 'Comparison of two culture methods for the enumeration of L. pneumophila from potable water samples', Journal of water and health, 19(3), pp. 468-477. Bonetta, S., Pignata, C., Bonetta, S., Meucci, L., Giacosa, D., Marino, E., Gilli, G. and Carraro, E. (2017) 'Viability of L. pneumophila in water samples: a comparison of propidium monoazide (PMA) treatment on membrane filters and in liquid', International journal of environmental research and public health, 14(5), pp. 467. Burillo, A., Pedro-Botet, M. L. and Bouza, E. (2017) 'Microbiology and epidemiology of Legionnaire's disease', Infectious Disease Clinics, 31(1), pp. 7-27. Buse, H. Y., Ji, P., Gomez‐Alvarez, V., Pruden, A., Edwards, M. A. and Ashbolt, N. J. (2017) 'Effect of temperature and colonization of L. pneumophila and Vermamoeba vermiformis on bacterial community composition of copper drinking water biofilms', Microbial biotechnology, 10(4), pp. 773-788. Campaña, M., Del Hoyo, R., Monleón-Getino, A. and Checa, J. (2023) 'Predicting Legionella contamination in cooling towers and evaporative condensers from microbiological and physicochemical parameters', International Journal of Hygiene and Environmental Health, 248, pp. 114117. Casino, P., López, A., Peiró, S., Ríos, M., Ríos, S., Porta, A., Agustí, G., Asensio, D., Marqués, A. M. and Piqué, N. (2022) 'GVPC medium manufactured without oxygen improves the growth of Legionella spp. and exhibits enhanced selectivity properties', Microbiology Spectrum, 10(2), pp. e02401-21. Cavallaro, A., Rhoads, W. J., Huwiler, S. G., Stachler, E. and Hammes, F. (2022) 'Potential probiotic approaches to control Legionella in engineered aquatic ecosystems', FEMS Microbiology Ecology, 98(8), pp. fiac071. Centers for Disease Control and Prevention (CDC). (2017). Developing a Water Management Program to Reduce Legionella Growth & Spread in Buildings—A Practical Guide to Implementing Industry Standards. Atlanta: U.S. Centers for Disease Control and Prevention. (2019). CDC Sampling Procedure and Potential Sampling Sites. Retrieved from https://www.cdc.gov/investigate-legionella/media/pdfs/cdc-sampling-procedure.pdf Collins, S., Stevenson, D., Walker, J. and Bennett, A. (2017) 'Evaluation of Legionella real‐time PCR against traditional culture for routine and public health testing of water samples', Journal of applied microbiology, 122(6), pp. 1692-1703. Costerton, J. W., Lewandowski, Z., Caldwell, D. E., Korber, D. R. and Lappin-Scott, H. M. (1995) ‘Microbial biofilms’, Annual Review of Microbiology, 49, pp. 711–745. Crook, B., Willerton, L., Smith, D., Wilson, L., Poran, V., Helps, J. and McDermott, P. (2020) 'Legionella risk in evaporative cooling systems and underlying causes of associated breaches in health and safety compliance', International journal of hygiene and environmental health, 224, pp. 113425. Cullom, A. C., Martin, R. L., Song, Y., Williams, K., Williams, A., Pruden, A. and Edwards, M. A. (2020) 'Critical review: propensity of premise plumbing pipe materials to enhance or diminish growth of Legionella and other opportunistic pathogens', Pathogens, 9(11), pp. 957. De Filippis, P., Mozzetti, C., Messina, A. and D'Alò, G. L. (2018) 'Prevalence of Legionella in retirement homes and group homes water distribution systems', Science of the total environment, 643, pp. 715-724. Declerck, P. (2010) 'Biofilms: the environmental playground of L. pneumophila ', Environmental microbiology, 12(3), pp. 557-566. Di Gregorio, L., Tandoi, V., Congestri, R., Rossetti, S. and Di Pippo, F. (2017) 'Unravelling the core microbiome of biofilms in cooling tower systems', Biofouling, 33(10), pp. 793-806. Di Pippo, F., Di Gregorio, L., Congestri, R., Tandoi, V. and Rossetti, S. (2018) 'Biofilm growth and control in cooling water industrial systems', FEMS microbiology ecology, 94(5), pp. fiy044. Díaz-Flores, Á., Montero, J. C., Castro, F. J., Alejandres, E. M., Bayón, C., Solís, I., Fernández-Lafuente, R. and Rodríguez, G. (2015) 'Comparing methods of determining Legionella spp. in complex water matrices', BMC microbiology, 15, pp. 1-9. Donohue, M. J., Vesper, S., Mistry, J. and Donohue, J. M. (2019) 'Impact of chlorine and chloramine on the detection and quantification of L. pneumophila and Mycobacterium species', Applied and environmental microbiology, 85(24), pp. e01942-19. Eble, D., Gehrig, V., Schubert‐Ullrich, P., Köppel, R. and Füchslin, H. (2021) 'Comparison of the culture method with multiplex PCR for the confirmation of Legionella spp. and L. pneumophila ', Journal of Applied Microbiology, 131(5), pp. 2600-2609. Ezenarro, J. J., Párraga-Niño, N., Sabrià, M., Del Campo, F. J., Muñoz-Pascual, F.-X., Mas, J. and Uria, N. (2020) 'Rapid detection of L. pneumophila in drinking water, based on filter immunoassay and chronoamperometric measurement', Biosensors, 10(9), pp. 102. Fields, B. S., Benson, R. F. and Besser, R. E. (2002) 'Legionella and Legionnaires' disease: 25 years of investigation', Clinical microbiology reviews, 15(3), pp. 506-526. Fish, K. E., Reeves-McLaren, N., Husband, S. and Boxall, J. (2020) 'Uncharted waters: the unintended impacts of residual chlorine on water quality and biofilms', npj Biofilms and Microbiomes, 6(1), pp. 34. Fisher, K. E., Wickenberg, L. P., Leonidas, L. F., Ranz, A. A., Habib, M. A., Buford, R. M. and McCoy, W. F. (2020) 'Next Day Legionella PCR: a highly reliable negative screen for Legionella in the built environment', Journal of Water and Health, 18(3), pp. 345-357. Flemming, H.-C., & Wingender, J. (2010). The biofilm matrix. Nature Reviews Microbiology, 8(9), 623–633. Flemming, H.-C., Wingender, J., Szewzyk, U., Steinberg, P., Rice, S. A. and Kjelleberg, S. (2016) 'Biofilms: an emergent form of bacterial life', Nature Reviews Microbiology, 14(9), pp. 563-575. Flemming, H.-C. (2020) 'Biofouling and me: My Stockholm syndrome with biofilms', Water research, 173, pp. 115576. Fliermans, C., Cherry, W., Orrison, L., Smith, S., Tison, D. and Pope, D. (1981) ‘Ecological distribution of L. pneumophila’, Applied and Environmental Microbiology, 41(1), pp. 9–16. Foster, K., Gorton, R. and Waller, J. (2006) ‘Outbreak of legionellosis associated with a spa pool, United Kingdom’, Weekly Releases (1997–2007), 11(38), p. 3053. Füchslin, H. P., Kötzsch, S., Keserue, H. A. and Egli, T. (2010) 'Rapid and quantitative detection of L. pneumophila applying immunomagnetic separation and flow cytometry', Cytometry Part A: The Journal of the International Society for Advancement of Cytometry, 77(3), pp. 264-274. Gabrielli, M., Turolla, A. and Antonelli, M. (2021) 'Bacterial dynamics in drinking water distribution systems and flow cytometry monitoring scheme optimization', Journal of Environmental Management, 286, pp. 112151. García, M.T., Jones, S., Pelaz, C., Millar, R.D. and Abu Kwaik, Y. (2007) 'Acanthamoeba polyphaga resuscitates viable non-culturable Legionella pneumophila after disinfection', Environmental Microbiology, 9(5), pp. 1267–1277. Garner, E., McLain, J., Bowers, J., Engelthaler, D. M., Edwards, M. A. and Pruden, A. (2018) 'Microbial ecology and water chemistry impact regrowth of opportunistic pathogens in full-scale reclaimed water distribution systems', Environmental science & technology, 52(16), pp. 9056-9068. Greenberg, S. G. (2021) Legionella Biofilm Formation Potential on Different Pipe Materials Used for Low Nutrient Municipality Tap Water. Arizona State University. Greub, G. and Raoult, D. (2004) ‘Microorganisms resistant to free-living amoebae’, Clinical Microbiology Reviews, 17(2), pp. 413–433. Hammer, E. (2018) Temporal and Ecological Community Dynamics of Water-Cooling Tower Associated Legionella spp. Clemson University. Health and Safety Executive (2014) HSG274 Part 1 Legionnaires' disease: The control of Legionella bacteria in evaporative cooling systems. Available at: https://www.hse.gov.uk/pubns/books/hsg274.htm (Accessed: 01/01/2023). Helmi, K., David, F., Di Martino, P., Jaffrezic, M.-P. and Ingrand, V. (2018) 'Assessment of flow cytometry for microbial water quality monitoring in cooling tower water and oxidizing biocide treatment efficiency', Journal of microbiological methods, 152, pp. 201-209. Hemmerling, C., Labrosse, A., Ruess, L. and Steinert, M. (2023) ‘L. pneumophila and free-living nematodes: Environmental co-occurrence and trophic link’, Microorganisms, 11(3), p. 738. Huang, S.-W., Hsu, B.-M., Wu, S.-F., Fan, C.-W., Shih, F.-C., Lin, Y.-C. and Ji, D.-D. (2010) ‘Water quality parameters associated with prevalence of Legionella in hot spring facility water bodies’, Water Research, 44(16), pp. 4805–4811. Huws, S., McBain, A. J. and Gilbert, P. (2005) ‘Protozoan grazing and its impact upon population dynamics in biofilm communities’, Journal of Applied Microbiology, 98(1), pp. 238–244. International Organization for Standardization (ISO) (1998) ISO 11731:1998 Water quality — Detection and enumeration of Legionella. Geneva: ISO. International Organization for Standardization (ISO) (2017) ISO 11731:2017 Water quality — Enumeration of Legionella. Geneva: ISO. Irons, J., Dunn, M., Kefala, K., Thorn, S., Lakha, F., Caesar, D. et al. (2013) ‘The effect of a large Legionnaires' disease outbreak in Southwest Edinburgh on acute and critical care services’, QJM: An International Journal of Medicine, 106(12), pp. 1087–1094. Islam, M. A., Hassen, W. M., Tayabali, A. F., & Dubowski, J. J. (2020). Antimicrobial warnericin RK peptide functionalized GaAs/AlGaAs biosensor for highly sensitive and selective detection of Legionella pneumophila. Biochemical Engineering Journal, 154, 107435 Isberg, R. R., O’Connor, T. J. and Heidtman, M. (2009) ‘The L. pneumophila replication vacuole: making a cosy niche inside host cells’, Nature Reviews Microbiology, 7(1), pp. 13–24. Jomehzadeh, N., Moosavian, M., Saki, M. and Rashno, M. (2019) 'Legionella and legionnaires' disease: An overview', Journal of Acute Disease, 8(6), pp. 221-232. Jürgens, K., & Matz, C. (2002). Predation as a shaping force for the phenotypic and genotypic composition of planktonic bacteria. Antonie van Leeuwenhoek, 81(1-4), 413–434. Kanarek, P., Bogiel, T. and Breza-Boruta, B. (2022) 'Legionellosis risk—an overview of Legionella spp. habitats in Europe', Environmental Science and Pollution Research, 29(51), pp. 76532-76542. Keserue, H.-A., Cornillie, N., Ehlert, A.-K., Mills, D. C., Morger, D., Piffaretti, A., Schaffhauser, D. F. and Schwyzer, I. I. (2021) 'Validation of the L. pneumophila SG1 DETECT Kit for Quantification of L. pneumophila Serogroup 1 Bacteria in Potable Waters, Process Waters, and Surface Waters: AOAC Performance Tested Methodsm 052002', Journal of AOAC International, 104(3), pp. 776-789. Keserue, H. A., Baumgartner, A., Felleisen, R. and Egli, T. (2012) 'Rapid detection of total and viable L egionella pneumophila in tap water by immunomagnetic separation, double fluorescent staining and flow cytometry', Microbial biotechnology, 5(6), pp. 753-763. Kyritsakas, G., Boxall, J. and Speight, V. (2023) 'Forecasting bacteriological presence in treated drinking water using machine learning', Frontiers in Water, 5, pp. 1199632. Learbuch, K., Smidt, H. and Van Der Wielen, P. (2021) 'Influence of pipe materials on the microbial community in unchlorinated drinking water and biofilm', Water Research, 194, pp. 116922. Leoni, E., Catalani, F., Marini, S. and Dallolio, L. (2018) ‘Legionellosis associated with recreational waters: a systematic review of cases and outbreaks in swimming pools, spa pools, and similar environments’, International Journal of Environmental Research and Public Health, 15(8), p. 1612. Liu, Z., Lin, Y., Stout, J., Hwang, C., Vidic, R. and Yu, V. (2006) ‘Effect of flow regimes on the presence of Legionella within the biofilm of a model plumbing system’, Journal of Applied Microbiology, 101(2), pp. 437–442. Llewellyn, A. C., Lucas, C. E., Roberts, S. E., Brown, E. W., Nayak, B. S., Raphael, B. H. and Winchell, J. M. (2017) 'Distribution of Legionella and bacterial community composition among regionally diverse US cooling towers', PloS one, 12(12), pp. e0189937. Loret, J.-F. and Greub, G. (2010) ‘Free-living amoebae: Biological by-passes in water treatment’, International Journal of Hygiene and Environmental Health, 213(3), pp. 167–175. Lucas, C. E., Taylor Jr, T. H. and Fields, B. S. (2011) 'Accuracy and precision of Legionella isolation by US laboratories in the ELITE program pilot study', Water research, 45(15), pp. 4428-4436. Margot, C., Rhoads, W., Gabrielli, M., Olive, M. and Hammes, F. (2024) ‘Dynamics of drinking water biofilm formation associated with Legionella spp. colonization’, npj Biofilms and Microbiomes, 10(1), p. 101. Martín-Muñoz, D., Tirado, D. F. and Calvo, L. (2022) 'Inactivation of Legionella in aqueous media by high-pressure carbon dioxide', The Journal of Supercritical Fluids, 180, pp. 105431. Mathieu, L., Paris, T. and Block, J.-C. (2019) 'Microbiome of drinking water distribution systems', The Structure and Function of Aquatic Microbial Communities, pp. 261-311. McDaniel, E. A., Wahl, S. A., Ishii, S. i., Pinto, A., Ziels, R., Nielsen, P. H. et al. (2021) ‘Prospects for multi-omics in the microbial ecology of water engineering’, Water Research, 205, p. 117608. Miller, R. D. and Koebel, D. A. (2006) 'Legionella prevalence in cooling towers: association with specific biocide treatments', ASHRAE transactions, 112, pp. 700. Monteiro, S. N., Robalo, A. M. and Santos, R. J. (2021) 'Evaluation of Legiolert™ for the detection of L. pneumophila and comparison with spread-plate culture and qPCR methods', Current Microbiology, 78(5), pp. 1792-1797. Nescerecka, A., Hammes, F. and Juhna, T. (2016) ‘A pipeline for developing and testing staining protocols for flow cytometry, demonstrated with SYBR Green I and propidium iodide viability staining’, Journal of Microbiological Methods, 131, pp. 172–180. Nisar, M. A., Ross, K. E., Brown, M. H., Bentham, R., & Whiley, H. (2020). Legionella pneumophila and Protozoan Hosts: Implications for the Control of Hospital and Potable Water Systems. Pathogens, 9(4), 286 Niu, C., Zhang, Y. and Zhang, Y. (2022) 'Evaluation of a most probable number method for detection and quantification of L. pneumophila ', Pathogens, 11(7), pp. 789. O'Mahony, M., Stanwell-Smith, R., Tillett, H., Harper, D., Hutchison, J., Farrell, I. et al. (1990) ‘The Stafford outbreak of Legionnaires’ disease’, Epidemiology & Infection, 104(3), pp. 361–380. Oliva, G., Sahr, T. and Buchrieser, C. (2018) 'The life cycle of L. pneumophila: cellular differentiation is linked to virulence and metabolism', Frontiers in cellular and infection microbiology, 8, pp. 3. Othieno, R., Evans, C., McCallum, A., McCormick, D., Stevenson, J., Donaghy, M. and Lakha, F. (2014) 'The 2012 Edinburgh Legionnaires' disease outbreak', Scottish Medical Journal, 59(1), pp. E23-E23. Paniagua, A. T., Paranjape, K., Hu, M., Bedard, E. and Faucher, S. P. (2020) 'Impact of temperature on L. pneumophila , its protozoan host cells, and the microbial diversity of the biofilm community of a pilot cooling tower', Science of the total environment, 712, pp. 136131. Paranjape, K., Bédard, É., Shetty, D., Hu, M., Choon, F. C. P., Prévost, M. and Faucher, S. P. (2020a) 'Unravelling the importance of the eukaryotic and bacterial communities and their relationship with Legionella spp. ecology in cooling towers: a complex network', Microbiome, 8, pp. 1-19. Paranjape, K., Bédard, É., Whyte, L. G., Ronholm, J., Prévost, M. and Faucher, S. P. (2020b) 'Presence of Legionella spp. in cooling towers: the role of microbial diversity, Pseudomonas, and continuous chlorine application', Water research, 169, pp. 115252. Párraga-Niño, N., Quero, S., Ventós-Alfonso, A., Uria, N., Castillo-Fernandez, O., Ezenarro, J. J., Muñoz, F.-X., Garcia-Nuñez, M. and Sabrià, M. (2018) 'New system for the detection of L. pneumophila in water samples', Talanta, 189, pp. 324-331. Paruch, L. (2022) 'Molecular diagnostic tools applied for assessing microbial water quality', International Journal of Environmental Research and Public Health, 19(9), pp. 5128. Paschke, A., Schaible, U. E. and Hein, W. (2019) 'Legionella transmission through cooling towers: towards better control and research of a neglected pathogen', The Lancet Respiratory Medicine, 7(5), pp. 378-380. Pécastaings, S., Bergé, M., Dubourg, K. and Roques, C. (2010) 'Sessile L. pneumophila is able to grow on surfaces and generate structured monospecies biofilms', Biofouling, 26(7), pp. 809-819. Pereira, A., Silva, A. R. and Melo, L. F. (2021) 'Legionella and biofilms—integrated surveillance to bridge science and real-field demands', Microorganisms, 9(6), pp. 1212. Pereira, R. P., Peplies, J., Höfle, M. G. and Brettar, I. (2017) 'Bacterial community dynamics in a cooling tower with emphasis on pathogenic bacteria and Legionella species using universal and genus-specific deep sequencing', Water research, 122, pp. 363-376. Phin, N., Parry-Ford, F., Harrison, T., Stagg, H. R., Zhang, N., Kumar, K., Lortholary, O., Zumla, A. and Abubakar, I. (2014) 'Epidemiology and clinical management of Legionnaires' disease', The Lancet infectious diseases, 14(10), pp. 1011-1021. Pick, F. C. and Fish, K. E. (2024) 'Emerging investigator series: optimisation of drinking water biofilm cell detachment and sample homogenisation methods for rapid quantification via flow cytometry', Environmental Science: Water Research & Technology, 10(4), pp. 797-813. Pierre, D., Baron, J. L., Ma, X., Sidari III, F. P., Wagener, M. M. and Stout, J. E. (2019) 'Water quality as a predictor of Legionella positivity of building water systems', Pathogens, 8(4), pp. 295. Pinel, I., Hankinson, P., Moed, D., Wyseure, L., Vrouwenvelder, J. S. and van Loosdrecht, M. C. (2021) 'Efficient cooling tower operation at alkaline pH for the control of L. pneumophila and other pathogenic genera', Water Research, 197, pp. 117047. Pinel, I., Moed, D., Vrouwenvelder, J. S. and Van Loosdrecht, M. (2020a) 'Bacterial community dynamics and disinfection impact in cooling water systems', Water research, 172, pp. 115505. Pinel, I. S., Kim, L. H., Proença Borges, V. R., Farhat, N. M., Witkamp, G.-J., van Loosdrecht, M. C. and Vrouwenvelder, J. S. (2020b) 'Effect of phosphate availability on biofilm formation in cooling towers', Biofouling, 36(7), pp. 800-815. Polwart, N., Grant, R., Barnes, H., Holmes, E., Lindley, T. and Cooper, A. 'A Field Test for Rapid Detection of L. pneumophila serogroup 1 in Water Samples'. Prevention, C. f. D. C. a. (2017) Developing a Water Management Program to Reduce Legionella Growth & Spread in Buildings—A Practical Guide to Implementing Industry Standards, Atlanta. Proctor, C. R., Dai, D., Edwards, M. A. and Pruden, A. (2017) 'Interactive effects of temperature, organic carbon, and pipe material on microbiota composition and L. pneumophila in hot water plumbing systems', Microbiome, 5, pp. 1-15. Proner, M. C., de Meneses, A. C., Veiga, A. A., Schluter, H., Oliveira, D. b. d. and Luccio, M. D. (2021) 'Industrial cooling systems and antibiofouling strategies: a comprehensive review', Industrial & Engineering Chemistry Research, 60(8), pp. 3278-3294. Rakić, A., Vukić Lušić, D. and Jurčev Savičević, A. (2022) 'Influence of metal concentration and plumbing materials on Legionella contamination', Microorganisms, 10(5), pp. 1051. Ridgway, H. and Olson, B. (1982) ‘Chlorine resistance patterns of bacteria from two drinking water distribution systems’, Applied and Environmental Microbiology, 44(4), pp. 972–987. Roeselers, G., Coolen, J., van der Wielen, P. W., Jaspers, M. C., Atsma, A., de Graaf, B. and Schuren, F. (2015) 'Microbial biogeography of drinking water: patterns in phylogenetic diversity across space and time', Environmental microbiology, 17(7), pp. 2505-2514. Samuelsson, J., Payne Hallström, L., Marrone, G., & Gomes Dias, J. (2023). Legionnaires’ disease in the EU/EEA*: increasing trend from 2017 to 2019. Eurosurveillance, 28(11) Sartory, D., Spies, K., Lange, B., Schneider, S. and Langer, B. (2017) ‘Evaluation of a most probable number method for the enumeration of L. pneumophila from potable and related water samples’, Letters in Applied Microbiology, 64(4), pp. 271–275. Scaturro, M., Poznanski, E., Mupo, M., Blasior, P., Seeber, M., Prast, A.-M., Romanin, E., Girolamo, A., Rota, M. C. and Bella, A. (2020) 'Evaluation of GVPC and BCYE media for Legionella detection and enumeration in water samples by ISO 11731: does plating on BCYE medium really improve yield?', Pathogens, 9(9), pp. 757. Schleich, C., Chan, S., Pullerits, K., Besmer, M. D., Paul, C. J., Rådström, P. and Keucken, A. (2019) 'Mapping dynamics of bacterial communities in a full-scale drinking water distribution system using flow cytometry', Water, 11(10), pp. 2137. Sciences, N. A. o., Division, M., Earth, D. o., Studies, L., Health, B. o. P., Practice, P. H., Sciences, B. o. L., Science, W., Board, T. and Systems, C. o. M. o. L. i. W. (2020) Management of Legionella in water systems. National Academies Press. Sciuto, E. L., Laganà, P., Filice, S., Scalese, S., Libertino, S., Corso, D., Faro, G. and Coniglio, M. A. (2021) 'Environmental management of Legionella in domestic water systems: Consolidated and innovative approaches for disinfection methods and risk assessment', Microorganisms, 9(3), pp. 577. Segal, G., Purcell, M. and Shuman, H. A. (1998) ‘Host cell killing and bacterial conjugation require overlapping sets of genes within a 22-kb region of the L. pneumophila genome’, Proceedings of the National Academy of Sciences, 95(4), pp. 1669–1674. Shaheen, M. and Ashbolt, N. J. (2021) 'Differential bacterial predation by free-living amoebae may result in blooms of Legionella in drinking water systems', Microorganisms, 9(1), pp. 174. Shaheen, M., Scott, C. and Ashbolt, N. J. (2019) 'Long-term persistence of infectious Legionella with free-living amoebae in drinking water biofilms', International journal of hygiene and environmental health, 222(4), pp. 678-686. Stewart, C. R., Muthye, V. and Cianciotto, N. P. (2012) 'L. pneumophila persists within biofilms formed by Klebsiella pneumoniae, Flavobacterium sp., and Pseudomonas fluorescens under dynamic flow conditions', PloS one, 7(11), pp. e50560. Streich, P., Redwitz, J., Walser-Reichenbach, S., Herr, C. E., Elsner, M. and Seidel, M. (2024) 'Culture-Independent Quantification of L. pneumophila in Evaporative Cooling Systems Using Immunomagnetic Separation Coupled with Flow Cytometry', Applied Microbiology, 4(1), pp. 284-296. Sun, Z., Bai, X., Chen, X., McCrae, D. and Saaski, E. (2013) ‘A simple, specific, and rapid lateral-flow immunochromatographic test method for detection of L. pneumophila in water samples’, International Proceedings of Chemical, Biological and Environmental Engineering, 58, pp. 125–130. Surman, S., Morton, G., Keevil, B. and Fitzgeorge, R. (2001) ‘L. pneumophila proliferation is not dependent on intracellular replication’, Legionella, pp. 86–89. Tan, B., Ng, C., Nshimyimana, J. P., Loh, L. L., Gin, K. Y.-H. and Thompson, J. R. (2015) ‘Next-generation sequencing (NGS) for assessment of microbial water quality: current progress, challenges, and future opportunities’, Frontiers in Microbiology, 6, p. 1027. Tan, L. T.-H., Tee, W. Y., Khan, T. M., Ming, L. C. and Letchumanan, V. (2021) 'L. pneumophila —The causative agent of Legionnaires’ disease', Progress In Microbes & Molecular Biology, 4(1). Taylor, M., Ross, K. and Bentham, R. (2009) 'Legionella, protozoa, and biofilms: interactions within complex microbial systems', Microbial ecology, 58, pp. 538-547. Taylor, M. J., Bentham, R. H. and Ross, K. E. (2014) 'Limitations of using propidium monoazide with qPCR to discriminate between live and dead Legionella in biofilm samples', Microbiology insights, 7, pp. MBI. S17723. Temmerman, R., Vervaeren, H., Noseda, B., Boon, N. and Verstraete, W. (2006) 'Necrotrophic growth of L. pneumophila ', Applied and environmental microbiology, 72(6), pp. 4323-4328. Tewari, R., Mehta, S. and Vaishnav, P. (2019) 'Influence of microbes in cooling tower: a review', Int Res J Eng Technol, 6(8), pp. 376-383. Thomas, J. M. and Ashbolt, N. J. (2011) ‘Do free-living amoebae in treated drinking water systems present an emerging health risk?’, Environmental Science & Technology, 45(3), pp. 860–869. Thom, C., Smith, C. J., Moore, G., Weir, P. and Ijaz, U. Z. (2022) 'Microbiomes in drinking water treatment and distribution: A meta-analysis from source to tap', Water Research, 212, pp. 118106. Toplitsch, D., Platzer, S., Zehner, R., Maitz, S., Mascher, F. and Kittinger, C. (2021) 'Comparison of updated methods for Legionella detection in environmental water samples', International Journal of Environmental Research and Public Health, 18(10), pp. 5436. Tsao, H.-F., Scheikl, U., Herbold, C., Indra, A., Walochnik, J., & Horn, M. (2019). The cooling tower water microbiota: Seasonal dynamics and co-occurrence of bacterial and protist phylotypes. Water Research, 159, 464–479 Van der Kooij, D., Veenendaal, H. R. and Scheffer, W. J. (2005) ‘Biofilm formation and multiplication of Legionella in a model warm water system with pipes of copper, stainless steel and cross-linked polyethylene’, Water Research, 39(13), pp. 2789–2798. Viasus, D., Gaia, V., Manzur-Barbur, C. and Carratalà, J. (2022) 'Legionnaires’ disease: update on diagnosis and treatment', Infectious Diseases and Therapy, 11(3), pp. 973-986. Waak, M. B., LaPara, T. M., Halle, C. and Hozalski, R. M. (2018) 'Occurrence of Legionella spp. in water-main biofilms from two drinking water distribution systems', Environmental science & technology, 52(14), pp. 7630-7639. Wade, W., Spratt, D., Dymock, D. and Weightman, A. (1997) 'Molecular detection of novel anaerobic species in dentoalveolar abscesses', Clinical infectious diseases, 25(Supplement_2), pp. S235-S236. Wadowsky, R. M., Wolford, R., McNamara, A. and Yee, R. B. (1985) 'Effect of temperature, pH, and oxygen level on the multiplication of naturally occurring L. pneumophila in potable water', Applied and environmental microbiology, 49(5), pp. 1197-1205. Wales, A. D. and Davies, R. H. (2015) 'Co-selection of resistance to antibiotics, biocides and heavy metals, and its relevance to foodborne pathogens', Antibiotics, 4(4), pp. 567-604. Walker, J. T. and McDermott, P. J. (2021) 'Confirming the presence of L. pneumophila in your water system: a review of current Legionella testing methods', Journal of AOAC International, 104(4), pp. 1135-1147. Wang, H., Proctor, C. R., Edwards, M. A., Pryor, M., Santo Domingo, J. W., Ryu, H., Camper, A. K., Olson, A. and Pruden, A. (2014) 'Microbial community response to chlorine conversion in a chloraminated drinking water distribution system', Environmental science & technology, 48(18), pp. 10624-10633. Wei, C., Yu, C., Meng, J., Li, J., Li, Q. and Li, S. (2023) 'Detachable and reassemble sandwiching device with high dynamic range for multivolume droplet digital polymerase chain reactions', Sensors and Actuators B: Chemical, pp. 135013. Whiley, H. and Taylor, M. (2016) 'Legionella detection by culture and qPCR: comparing apples and oranges', Critical reviews in microbiology, 42(1), pp. 65-74. World Health Organization (WHO) (2007) Legionella and the prevention of legionellosis. Geneva: World Health Organization. Available at: https://apps.who.int/iris/handle/10665/43233 (Accessed: 19 December 2024). Yamaguchi, N., Tokunaga, Y., Goto, S., Fujii, Y., Banno, F. and Edagawa, A. (2017) 'Rapid on-site monitoring of L. pneumophila in cooling tower water using a portable microfluidic system', Scientific reports, 7(1), pp. 3092. Young, C., Smith, D., Wafer, T. and Crook, B. (2021) 'Rapid testing and interventions to control Legionella proliferation following a Legionnaires’ disease outbreak associated with cooling towers', Microorganisms, 9(3), pp. 615. Zhang, Y. and Liu, W.-T. (2019) 'The application of molecular tools to study the drinking water microbiome–Current understanding and future needs', Critical Reviews in Environmental Science and Technology, 49(13), pp. 1188-1235. Zhang, L., Fritsch, M., Hammond, L., Landini, P., & Kjelleberg, S. (2023). Understanding bacterial biofilms: From definition to treatment strategies. Frontiers in Cellular and Infection Microbiology, 13, 1137947."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/36308/1/MK%20PHD%20White%20Rose%20Submission.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Legionella pneumophila, a waterborne bacterium, is the primary cause of Legionnaires’ disease, a severe form of pneumonia contracted through the inhalation of contaminated aerosols. While this study focuses on L. pneumophila, other species, such as Legionella longbeachae, can also cause the disease, particularly in Australia and New Zealand. Cooling towers are a predominant source of Legionnaires' outbreaks, as they support the growth of both sessile and planktonic microbial communities and facilitate their aerosolisation. Therefore, microbial growth within these structures must be rigorously controlled through a variety of control measures. Currently, the efficacy of these control measures is assessed by routine monitoring of bulk water samples using culture-based methods. However, this reliance on planktonic samples combined with culture methods, typically delays remedial actions, allowing outbreaks to occur. This thesis aims to minimise the delay between the detection of Legionella and the implementation of remedial actions to prevent outbreaks. It hypothesises that biofilm samples could potentially serve as lead indicators for the rapid detection of L. pneumophila, thereby enabling timely corrective measures. Additionally, this research explores how biofilm samples enhance our understanding of interactions between biofilms, planktonic communities, and physicochemical parameters, potentially revealing key factors and trends that influence Legionella growth and lead to outbreaks. To investigate whether biofilm samples could serve as lead indicators for Legionella detection, a novel and optimised biofilm sampling technique was developed and subsequently employed. This method was complemented by independently assessed emerging detection techniques and applied across four strategically selected operational cooling towers over an 18-month period. Additionally, the impact of microbial concentration, viability, and bacterial community structure was examined using flow cytometry and 16S rRNA bacterial community analysis, respectively. This approach significantly enhanced the likelihood of identifying precursor events indicative of Legionella presence. The research revealed that biofilm samples exclusively identified L. pneumophila during the study period, with Legionella spp. found in higher concentrations in biofilms compared to bulk water. This underscores biofilms as a crucial ecological niche for Legionella spp. Although bacterial concentrations, viability, and physicochemical parameters were found to be insufficient predictors of Legionella proliferation, the composition of the bacterial community within biofilms played a pivotal role. Biofilms, while sharing a core set of taxa with bulk water, exhibited a unique community dominated by low-abundance and rare taxa that significantly influenced microbial interactions and ecological dynamics. These dynamics include the introduction of additional organic compounds and nitrogen, as well as the potential reduction of competitive bacterial populations, which can foster the growth of L. pneumophila. These findings suggest that biofilms can serve as a lead indicator for L. pneumophila, highlighting the need for more comprehensive monitoring policies, practices, and regulations. Such measures should include the assessment of biofilm samples alongside traditional planktonic samples. Prioritising biofilm samples provides a more accurate and holistic understanding of the dynamics of Legionella, revealing crucial insights into the microbial communities that foster conditions conducive to the presence of L. pneumophila. Therefore, integrating biofilm sampling into current monitoring strategies will not only enhance our understanding of Legionella proliferation but also allow for the earlier implementation of remedial actions. Ultimately, this approach is expected to reduce the risk of Legionella outbreaks, thereby safeguarding public health."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Monitoring and Detecting Legionella within Evaporative Cooling Towers"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fish, Katherine"],"dc:contributor.sponsor":["HSE","Sellafield"],"dc:creator":["KERRY, MICHAEL"],"dc:date":["2024-05"],"dc:date.issued":["2024-05"],"dc:description.abstract":["Legionella pneumophila, a waterborne bacterium, is the primary cause of Legionnaires’ disease, a severe form of pneumonia contracted through the inhalation of contaminated aerosols. While this study focuses on L. pneumophila, other species, such as Legionella longbeachae, can also cause the disease, particularly in Australia and New Zealand. Cooling towers are a predominant source of Legionnaires' outbreaks, as they support the growth of both sessile and planktonic microbial communities and facilitate their aerosolisation. Therefore, microbial growth within these structures must be rigorously controlled through a variety of control measures. Currently, the efficacy of these control measures is assessed by routine monitoring of bulk water samples using culture-based methods. However, this reliance on planktonic samples combined with culture methods, typically delays remedial actions, allowing outbreaks to occur. This thesis aims to minimise the delay between the detection of Legionella and the implementation of remedial actions to prevent outbreaks. It hypothesises that biofilm samples could potentially serve as lead indicators for the rapid detection of L. pneumophila, thereby enabling timely corrective measures. Additionally, this research explores how biofilm samples enhance our understanding of interactions between biofilms, planktonic communities, and physicochemical parameters, potentially revealing key factors and trends that influence Legionella growth and lead to outbreaks. To investigate whether biofilm samples could serve as lead indicators for Legionella detection, a novel and optimised biofilm sampling technique was developed and subsequently employed. This method was complemented by independently assessed emerging detection techniques and applied across four strategically selected operational cooling towers over an 18-month period. Additionally, the impact of microbial concentration, viability, and bacterial community structure was examined using flow cytometry and 16S rRNA bacterial community analysis, respectively. This approach significantly enhanced the likelihood of identifying precursor events indicative of Legionella presence. The research revealed that biofilm samples exclusively identified L. pneumophila during the study period, with Legionella spp. found in higher concentrations in biofilms compared to bulk water. This underscores biofilms as a crucial ecological niche for Legionella spp. Although bacterial concentrations, viability, and physicochemical parameters were found to be insufficient predictors of Legionella proliferation, the composition of the bacterial community within biofilms played a pivotal role. Biofilms, while sharing a core set of taxa with bulk water, exhibited a unique community dominated by low-abundance and rare taxa that significantly influenced microbial interactions and ecological dynamics. These dynamics include the introduction of additional organic compounds and nitrogen, as well as the potential reduction of competitive bacterial populations, which can foster the growth of L. pneumophila. These findings suggest that biofilms can serve as a lead indicator for L. pneumophila, highlighting the need for more comprehensive monitoring policies, practices, and regulations. Such measures should include the assessment of biofilm samples alongside traditional planktonic samples. Prioritising biofilm samples provides a more accurate and holistic understanding of the dynamics of Legionella, revealing crucial insights into the microbial communities that foster conditions conducive to the presence of L. pneumophila. Therefore, integrating biofilm sampling into current monitoring strategies will not only enhance our understanding of Legionella proliferation but also allow for the earlier implementation of remedial actions. Ultimately, this approach is expected to reduce the risk of Legionella outbreaks, thereby safeguarding public health."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/36308/1/MK%20PHD%20White%20Rose%20Submission.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Civil and Structural Engineering (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/36308/"],"dc:relation.references":["Abdel-Nour, M., Duncan, C., Low, D. E. and Guyard, C. (2013) 'Biofilms: the stronghold of L. pneumophila ', International journal of molecular sciences, 14(11), pp. 21660-21675. Abu Khweek, A. and Amer, A. O. (2018) 'Factors mediating environmental biofilm formation by L. pneumophila ', Frontiers in cellular and infection microbiology, 8, pp. 38. Aloraini, S., Alum, A. and Abbaszadegan, M. (2023) 'Impact of pipe material and temperature on drinking water microbiome and prevalence of Legionella, Mycobacterium, and Pseudomonas species', Microorganisms, 11(2), pp. 352. Alrahimi, J., Aldahlawi, A., Hassoubah, S., Al-Jadani, S., Alyamani, W. and Alotaibi, N. (2022) 'An Insight into the Microbiology, Epidemiology, and Host Cell Biology of L. pneumophila : A Review of Literature', Biosciences Biotechnology Research Asia, 19(3), pp. 561-577. Ames, N. J., Ranucci, A., Moriyama, B. and Wallen, G. R. (2017) 'The human microbiome and understanding the 16S rRNA gene in translational nursing science', Nursing research, 66(2), pp. 184-197. Ashbolt, N. J. (2015) 'Microbial contamination of drinking water and human health from community water systems', Current environmental health reports, 2, pp. 95-106. ASHRAE (2018) 188: In Legionellosis: Risk Management for Building Water Systems; American Society of Heating, Refrigerating and Air- Conditioning Engineers. Atlanta: ASHRAE. Azeredo, J., Azevedo, N. F., Briandet, R., Cerca, N., Coenye, T., Costa, A. R., Desvaux, M., Di Bonaventura, G., Hébraud, M., Jaglic, Z., & Kačániová, M. (2017). Critical review on biofilm methods. Critical Reviews in Microbiology, 43(3), 313-351. Barrette, I. (2019) 'Comparison of Legiolert and a conventional culture method for detection of L. pneumophila from cooling towers in Québec', Journal of AOAC International, 102(4), pp. 1235-1240. Bautista-de los Santos, Q. M., Schroeder, J. L., Sevillano-Rivera, M. C., Sungthong, R., Ijaz, U. Z., Sloan, W. T. and Pinto, A. J. (2016) 'Emerging investigators series: microbial communities in full-scale drinking water distribution systems–a meta-analysis', Environmental Science: Water Research & Technology, 2(4), pp. 631-644. Bedrina, B., Macián, S., Solís, I., Fernández-Lafuente, R., Baldrich, E. and Rodríguez, G. (2013) 'Fast immunosensing technique to detect L. pneumophila in different natural and anthropogenic environments: comparative and collaborative trials', BMC microbiology, 13, pp. 1-9. Boamah, D. K., Zhou, G., Ensminger, A. W. and O’Connor, T. J. (2017) ‘From many hosts, one accidental pathogen: the diverse protozoan hosts of Legionella’, Frontiers in Cellular and Infection Microbiology, 7, p. 477. Boczek, L. A., Tang, M., Formal, C., Lytle, D. and Ryu, H. (2021) 'Comparison of two culture methods for the enumeration of L. pneumophila from potable water samples', Journal of water and health, 19(3), pp. 468-477. Bonetta, S., Pignata, C., Bonetta, S., Meucci, L., Giacosa, D., Marino, E., Gilli, G. and Carraro, E. (2017) 'Viability of L. pneumophila in water samples: a comparison of propidium monoazide (PMA) treatment on membrane filters and in liquid', International journal of environmental research and public health, 14(5), pp. 467. Burillo, A., Pedro-Botet, M. L. and Bouza, E. (2017) 'Microbiology and epidemiology of Legionnaire's disease', Infectious Disease Clinics, 31(1), pp. 7-27. Buse, H. Y., Ji, P., Gomez‐Alvarez, V., Pruden, A., Edwards, M. A. and Ashbolt, N. J. (2017) 'Effect of temperature and colonization of L. pneumophila and Vermamoeba vermiformis on bacterial community composition of copper drinking water biofilms', Microbial biotechnology, 10(4), pp. 773-788. Campaña, M., Del Hoyo, R., Monleón-Getino, A. and Checa, J. (2023) 'Predicting Legionella contamination in cooling towers and evaporative condensers from microbiological and physicochemical parameters', International Journal of Hygiene and Environmental Health, 248, pp. 114117. Casino, P., López, A., Peiró, S., Ríos, M., Ríos, S., Porta, A., Agustí, G., Asensio, D., Marqués, A. M. and Piqué, N. (2022) 'GVPC medium manufactured without oxygen improves the growth of Legionella spp. and exhibits enhanced selectivity properties', Microbiology Spectrum, 10(2), pp. e02401-21. Cavallaro, A., Rhoads, W. J., Huwiler, S. G., Stachler, E. and Hammes, F. (2022) 'Potential probiotic approaches to control Legionella in engineered aquatic ecosystems', FEMS Microbiology Ecology, 98(8), pp. fiac071. Centers for Disease Control and Prevention (CDC). (2017). Developing a Water Management Program to Reduce Legionella Growth & Spread in Buildings—A Practical Guide to Implementing Industry Standards. Atlanta: U.S. Centers for Disease Control and Prevention. (2019). CDC Sampling Procedure and Potential Sampling Sites. Retrieved from https://www.cdc.gov/investigate-legionella/media/pdfs/cdc-sampling-procedure.pdf Collins, S., Stevenson, D., Walker, J. and Bennett, A. (2017) 'Evaluation of Legionella real‐time PCR against traditional culture for routine and public health testing of water samples', Journal of applied microbiology, 122(6), pp. 1692-1703. Costerton, J. W., Lewandowski, Z., Caldwell, D. E., Korber, D. R. and Lappin-Scott, H. M. (1995) ‘Microbial biofilms’, Annual Review of Microbiology, 49, pp. 711–745. Crook, B., Willerton, L., Smith, D., Wilson, L., Poran, V., Helps, J. and McDermott, P. (2020) 'Legionella risk in evaporative cooling systems and underlying causes of associated breaches in health and safety compliance', International journal of hygiene and environmental health, 224, pp. 113425. Cullom, A. C., Martin, R. L., Song, Y., Williams, K., Williams, A., Pruden, A. and Edwards, M. A. (2020) 'Critical review: propensity of premise plumbing pipe materials to enhance or diminish growth of Legionella and other opportunistic pathogens', Pathogens, 9(11), pp. 957. De Filippis, P., Mozzetti, C., Messina, A. and D'Alò, G. L. (2018) 'Prevalence of Legionella in retirement homes and group homes water distribution systems', Science of the total environment, 643, pp. 715-724. Declerck, P. (2010) 'Biofilms: the environmental playground of L. pneumophila ', Environmental microbiology, 12(3), pp. 557-566. Di Gregorio, L., Tandoi, V., Congestri, R., Rossetti, S. and Di Pippo, F. (2017) 'Unravelling the core microbiome of biofilms in cooling tower systems', Biofouling, 33(10), pp. 793-806. Di Pippo, F., Di Gregorio, L., Congestri, R., Tandoi, V. and Rossetti, S. (2018) 'Biofilm growth and control in cooling water industrial systems', FEMS microbiology ecology, 94(5), pp. fiy044. Díaz-Flores, Á., Montero, J. C., Castro, F. J., Alejandres, E. M., Bayón, C., Solís, I., Fernández-Lafuente, R. and Rodríguez, G. (2015) 'Comparing methods of determining Legionella spp. in complex water matrices', BMC microbiology, 15, pp. 1-9. Donohue, M. J., Vesper, S., Mistry, J. and Donohue, J. M. (2019) 'Impact of chlorine and chloramine on the detection and quantification of L. pneumophila and Mycobacterium species', Applied and environmental microbiology, 85(24), pp. e01942-19. Eble, D., Gehrig, V., Schubert‐Ullrich, P., Köppel, R. and Füchslin, H. (2021) 'Comparison of the culture method with multiplex PCR for the confirmation of Legionella spp. and L. pneumophila ', Journal of Applied Microbiology, 131(5), pp. 2600-2609. Ezenarro, J. J., Párraga-Niño, N., Sabrià, M., Del Campo, F. J., Muñoz-Pascual, F.-X., Mas, J. and Uria, N. (2020) 'Rapid detection of L. pneumophila in drinking water, based on filter immunoassay and chronoamperometric measurement', Biosensors, 10(9), pp. 102. Fields, B. S., Benson, R. F. and Besser, R. E. (2002) 'Legionella and Legionnaires' disease: 25 years of investigation', Clinical microbiology reviews, 15(3), pp. 506-526. Fish, K. E., Reeves-McLaren, N., Husband, S. and Boxall, J. (2020) 'Uncharted waters: the unintended impacts of residual chlorine on water quality and biofilms', npj Biofilms and Microbiomes, 6(1), pp. 34. Fisher, K. E., Wickenberg, L. P., Leonidas, L. F., Ranz, A. A., Habib, M. A., Buford, R. M. and McCoy, W. F. (2020) 'Next Day Legionella PCR: a highly reliable negative screen for Legionella in the built environment', Journal of Water and Health, 18(3), pp. 345-357. Flemming, H.-C., & Wingender, J. (2010). The biofilm matrix. Nature Reviews Microbiology, 8(9), 623–633. Flemming, H.-C., Wingender, J., Szewzyk, U., Steinberg, P., Rice, S. A. and Kjelleberg, S. (2016) 'Biofilms: an emergent form of bacterial life', Nature Reviews Microbiology, 14(9), pp. 563-575. Flemming, H.-C. (2020) 'Biofouling and me: My Stockholm syndrome with biofilms', Water research, 173, pp. 115576. Fliermans, C., Cherry, W., Orrison, L., Smith, S., Tison, D. and Pope, D. (1981) ‘Ecological distribution of L. pneumophila’, Applied and Environmental Microbiology, 41(1), pp. 9–16. Foster, K., Gorton, R. and Waller, J. (2006) ‘Outbreak of legionellosis associated with a spa pool, United Kingdom’, Weekly Releases (1997–2007), 11(38), p. 3053. Füchslin, H. P., Kötzsch, S., Keserue, H. A. and Egli, T. (2010) 'Rapid and quantitative detection of L. pneumophila applying immunomagnetic separation and flow cytometry', Cytometry Part A: The Journal of the International Society for Advancement of Cytometry, 77(3), pp. 264-274. Gabrielli, M., Turolla, A. and Antonelli, M. (2021) 'Bacterial dynamics in drinking water distribution systems and flow cytometry monitoring scheme optimization', Journal of Environmental Management, 286, pp. 112151. García, M.T., Jones, S., Pelaz, C., Millar, R.D. and Abu Kwaik, Y. (2007) 'Acanthamoeba polyphaga resuscitates viable non-culturable Legionella pneumophila after disinfection', Environmental Microbiology, 9(5), pp. 1267–1277. Garner, E., McLain, J., Bowers, J., Engelthaler, D. M., Edwards, M. A. and Pruden, A. (2018) 'Microbial ecology and water chemistry impact regrowth of opportunistic pathogens in full-scale reclaimed water distribution systems', Environmental science & technology, 52(16), pp. 9056-9068. Greenberg, S. G. (2021) Legionella Biofilm Formation Potential on Different Pipe Materials Used for Low Nutrient Municipality Tap Water. Arizona State University. Greub, G. and Raoult, D. (2004) ‘Microorganisms resistant to free-living amoebae’, Clinical Microbiology Reviews, 17(2), pp. 413–433. Hammer, E. (2018) Temporal and Ecological Community Dynamics of Water-Cooling Tower Associated Legionella spp. Clemson University. Health and Safety Executive (2014) HSG274 Part 1 Legionnaires' disease: The control of Legionella bacteria in evaporative cooling systems. Available at: https://www.hse.gov.uk/pubns/books/hsg274.htm (Accessed: 01/01/2023). Helmi, K., David, F., Di Martino, P., Jaffrezic, M.-P. and Ingrand, V. (2018) 'Assessment of flow cytometry for microbial water quality monitoring in cooling tower water and oxidizing biocide treatment efficiency', Journal of microbiological methods, 152, pp. 201-209. Hemmerling, C., Labrosse, A., Ruess, L. and Steinert, M. (2023) ‘L. pneumophila and free-living nematodes: Environmental co-occurrence and trophic link’, Microorganisms, 11(3), p. 738. Huang, S.-W., Hsu, B.-M., Wu, S.-F., Fan, C.-W., Shih, F.-C., Lin, Y.-C. and Ji, D.-D. (2010) ‘Water quality parameters associated with prevalence of Legionella in hot spring facility water bodies’, Water Research, 44(16), pp. 4805–4811. Huws, S., McBain, A. J. and Gilbert, P. (2005) ‘Protozoan grazing and its impact upon population dynamics in biofilm communities’, Journal of Applied Microbiology, 98(1), pp. 238–244. International Organization for Standardization (ISO) (1998) ISO 11731:1998 Water quality — Detection and enumeration of Legionella. Geneva: ISO. International Organization for Standardization (ISO) (2017) ISO 11731:2017 Water quality — Enumeration of Legionella. Geneva: ISO. Irons, J., Dunn, M., Kefala, K., Thorn, S., Lakha, F., Caesar, D. et al. (2013) ‘The effect of a large Legionnaires' disease outbreak in Southwest Edinburgh on acute and critical care services’, QJM: An International Journal of Medicine, 106(12), pp. 1087–1094. Islam, M. A., Hassen, W. M., Tayabali, A. F., & Dubowski, J. J. (2020). Antimicrobial warnericin RK peptide functionalized GaAs/AlGaAs biosensor for highly sensitive and selective detection of Legionella pneumophila. Biochemical Engineering Journal, 154, 107435 Isberg, R. R., O’Connor, T. J. and Heidtman, M. (2009) ‘The L. pneumophila replication vacuole: making a cosy niche inside host cells’, Nature Reviews Microbiology, 7(1), pp. 13–24. Jomehzadeh, N., Moosavian, M., Saki, M. and Rashno, M. (2019) 'Legionella and legionnaires' disease: An overview', Journal of Acute Disease, 8(6), pp. 221-232. Jürgens, K., & Matz, C. (2002). Predation as a shaping force for the phenotypic and genotypic composition of planktonic bacteria. Antonie van Leeuwenhoek, 81(1-4), 413–434. Kanarek, P., Bogiel, T. and Breza-Boruta, B. (2022) 'Legionellosis risk—an overview of Legionella spp. habitats in Europe', Environmental Science and Pollution Research, 29(51), pp. 76532-76542. Keserue, H.-A., Cornillie, N., Ehlert, A.-K., Mills, D. C., Morger, D., Piffaretti, A., Schaffhauser, D. F. and Schwyzer, I. I. (2021) 'Validation of the L. pneumophila SG1 DETECT Kit for Quantification of L. pneumophila Serogroup 1 Bacteria in Potable Waters, Process Waters, and Surface Waters: AOAC Performance Tested Methodsm 052002', Journal of AOAC International, 104(3), pp. 776-789. Keserue, H. A., Baumgartner, A., Felleisen, R. and Egli, T. (2012) 'Rapid detection of total and viable L egionella pneumophila in tap water by immunomagnetic separation, double fluorescent staining and flow cytometry', Microbial biotechnology, 5(6), pp. 753-763. Kyritsakas, G., Boxall, J. and Speight, V. (2023) 'Forecasting bacteriological presence in treated drinking water using machine learning', Frontiers in Water, 5, pp. 1199632. Learbuch, K., Smidt, H. and Van Der Wielen, P. (2021) 'Influence of pipe materials on the microbial community in unchlorinated drinking water and biofilm', Water Research, 194, pp. 116922. Leoni, E., Catalani, F., Marini, S. and Dallolio, L. (2018) ‘Legionellosis associated with recreational waters: a systematic review of cases and outbreaks in swimming pools, spa pools, and similar environments’, International Journal of Environmental Research and Public Health, 15(8), p. 1612. Liu, Z., Lin, Y., Stout, J., Hwang, C., Vidic, R. and Yu, V. (2006) ‘Effect of flow regimes on the presence of Legionella within the biofilm of a model plumbing system’, Journal of Applied Microbiology, 101(2), pp. 437–442. Llewellyn, A. C., Lucas, C. E., Roberts, S. E., Brown, E. W., Nayak, B. S., Raphael, B. H. and Winchell, J. M. (2017) 'Distribution of Legionella and bacterial community composition among regionally diverse US cooling towers', PloS one, 12(12), pp. e0189937. Loret, J.-F. and Greub, G. (2010) ‘Free-living amoebae: Biological by-passes in water treatment’, International Journal of Hygiene and Environmental Health, 213(3), pp. 167–175. Lucas, C. E., Taylor Jr, T. H. and Fields, B. S. (2011) 'Accuracy and precision of Legionella isolation by US laboratories in the ELITE program pilot study', Water research, 45(15), pp. 4428-4436. Margot, C., Rhoads, W., Gabrielli, M., Olive, M. and Hammes, F. (2024) ‘Dynamics of drinking water biofilm formation associated with Legionella spp. colonization’, npj Biofilms and Microbiomes, 10(1), p. 101. Martín-Muñoz, D., Tirado, D. F. and Calvo, L. (2022) 'Inactivation of Legionella in aqueous media by high-pressure carbon dioxide', The Journal of Supercritical Fluids, 180, pp. 105431. Mathieu, L., Paris, T. and Block, J.-C. (2019) 'Microbiome of drinking water distribution systems', The Structure and Function of Aquatic Microbial Communities, pp. 261-311. McDaniel, E. A., Wahl, S. A., Ishii, S. i., Pinto, A., Ziels, R., Nielsen, P. H. et al. (2021) ‘Prospects for multi-omics in the microbial ecology of water engineering’, Water Research, 205, p. 117608. Miller, R. D. and Koebel, D. A. (2006) 'Legionella prevalence in cooling towers: association with specific biocide treatments', ASHRAE transactions, 112, pp. 700. Monteiro, S. N., Robalo, A. M. and Santos, R. J. (2021) 'Evaluation of Legiolert™ for the detection of L. pneumophila and comparison with spread-plate culture and qPCR methods', Current Microbiology, 78(5), pp. 1792-1797. Nescerecka, A., Hammes, F. and Juhna, T. (2016) ‘A pipeline for developing and testing staining protocols for flow cytometry, demonstrated with SYBR Green I and propidium iodide viability staining’, Journal of Microbiological Methods, 131, pp. 172–180. Nisar, M. A., Ross, K. E., Brown, M. H., Bentham, R., & Whiley, H. (2020). Legionella pneumophila and Protozoan Hosts: Implications for the Control of Hospital and Potable Water Systems. Pathogens, 9(4), 286 Niu, C., Zhang, Y. and Zhang, Y. (2022) 'Evaluation of a most probable number method for detection and quantification of L. pneumophila ', Pathogens, 11(7), pp. 789. O'Mahony, M., Stanwell-Smith, R., Tillett, H., Harper, D., Hutchison, J., Farrell, I. et al. (1990) ‘The Stafford outbreak of Legionnaires’ disease’, Epidemiology & Infection, 104(3), pp. 361–380. Oliva, G., Sahr, T. and Buchrieser, C. (2018) 'The life cycle of L. pneumophila: cellular differentiation is linked to virulence and metabolism', Frontiers in cellular and infection microbiology, 8, pp. 3. Othieno, R., Evans, C., McCallum, A., McCormick, D., Stevenson, J., Donaghy, M. and Lakha, F. (2014) 'The 2012 Edinburgh Legionnaires' disease outbreak', Scottish Medical Journal, 59(1), pp. E23-E23. Paniagua, A. T., Paranjape, K., Hu, M., Bedard, E. and Faucher, S. P. (2020) 'Impact of temperature on L. pneumophila , its protozoan host cells, and the microbial diversity of the biofilm community of a pilot cooling tower', Science of the total environment, 712, pp. 136131. Paranjape, K., Bédard, É., Shetty, D., Hu, M., Choon, F. C. P., Prévost, M. and Faucher, S. P. (2020a) 'Unravelling the importance of the eukaryotic and bacterial communities and their relationship with Legionella spp. ecology in cooling towers: a complex network', Microbiome, 8, pp. 1-19. Paranjape, K., Bédard, É., Whyte, L. G., Ronholm, J., Prévost, M. and Faucher, S. P. (2020b) 'Presence of Legionella spp. in cooling towers: the role of microbial diversity, Pseudomonas, and continuous chlorine application', Water research, 169, pp. 115252. Párraga-Niño, N., Quero, S., Ventós-Alfonso, A., Uria, N., Castillo-Fernandez, O., Ezenarro, J. J., Muñoz, F.-X., Garcia-Nuñez, M. and Sabrià, M. (2018) 'New system for the detection of L. pneumophila in water samples', Talanta, 189, pp. 324-331. Paruch, L. (2022) 'Molecular diagnostic tools applied for assessing microbial water quality', International Journal of Environmental Research and Public Health, 19(9), pp. 5128. Paschke, A., Schaible, U. E. and Hein, W. (2019) 'Legionella transmission through cooling towers: towards better control and research of a neglected pathogen', The Lancet Respiratory Medicine, 7(5), pp. 378-380. Pécastaings, S., Bergé, M., Dubourg, K. and Roques, C. (2010) 'Sessile L. pneumophila is able to grow on surfaces and generate structured monospecies biofilms', Biofouling, 26(7), pp. 809-819. Pereira, A., Silva, A. R. and Melo, L. F. (2021) 'Legionella and biofilms—integrated surveillance to bridge science and real-field demands', Microorganisms, 9(6), pp. 1212. Pereira, R. P., Peplies, J., Höfle, M. G. and Brettar, I. (2017) 'Bacterial community dynamics in a cooling tower with emphasis on pathogenic bacteria and Legionella species using universal and genus-specific deep sequencing', Water research, 122, pp. 363-376. Phin, N., Parry-Ford, F., Harrison, T., Stagg, H. R., Zhang, N., Kumar, K., Lortholary, O., Zumla, A. and Abubakar, I. (2014) 'Epidemiology and clinical management of Legionnaires' disease', The Lancet infectious diseases, 14(10), pp. 1011-1021. Pick, F. C. and Fish, K. E. (2024) 'Emerging investigator series: optimisation of drinking water biofilm cell detachment and sample homogenisation methods for rapid quantification via flow cytometry', Environmental Science: Water Research & Technology, 10(4), pp. 797-813. Pierre, D., Baron, J. L., Ma, X., Sidari III, F. P., Wagener, M. M. and Stout, J. E. (2019) 'Water quality as a predictor of Legionella positivity of building water systems', Pathogens, 8(4), pp. 295. Pinel, I., Hankinson, P., Moed, D., Wyseure, L., Vrouwenvelder, J. S. and van Loosdrecht, M. C. (2021) 'Efficient cooling tower operation at alkaline pH for the control of L. pneumophila and other pathogenic genera', Water Research, 197, pp. 117047. Pinel, I., Moed, D., Vrouwenvelder, J. S. and Van Loosdrecht, M. (2020a) 'Bacterial community dynamics and disinfection impact in cooling water systems', Water research, 172, pp. 115505. Pinel, I. S., Kim, L. H., Proença Borges, V. R., Farhat, N. M., Witkamp, G.-J., van Loosdrecht, M. C. and Vrouwenvelder, J. S. (2020b) 'Effect of phosphate availability on biofilm formation in cooling towers', Biofouling, 36(7), pp. 800-815. Polwart, N., Grant, R., Barnes, H., Holmes, E., Lindley, T. and Cooper, A. 'A Field Test for Rapid Detection of L. pneumophila serogroup 1 in Water Samples'. Prevention, C. f. D. C. a. (2017) Developing a Water Management Program to Reduce Legionella Growth & Spread in Buildings—A Practical Guide to Implementing Industry Standards, Atlanta. Proctor, C. R., Dai, D., Edwards, M. A. and Pruden, A. (2017) 'Interactive effects of temperature, organic carbon, and pipe material on microbiota composition and L. pneumophila in hot water plumbing systems', Microbiome, 5, pp. 1-15. Proner, M. C., de Meneses, A. C., Veiga, A. A., Schluter, H., Oliveira, D. b. d. and Luccio, M. D. (2021) 'Industrial cooling systems and antibiofouling strategies: a comprehensive review', Industrial & Engineering Chemistry Research, 60(8), pp. 3278-3294. Rakić, A., Vukić Lušić, D. and Jurčev Savičević, A. (2022) 'Influence of metal concentration and plumbing materials on Legionella contamination', Microorganisms, 10(5), pp. 1051. Ridgway, H. and Olson, B. (1982) ‘Chlorine resistance patterns of bacteria from two drinking water distribution systems’, Applied and Environmental Microbiology, 44(4), pp. 972–987. Roeselers, G., Coolen, J., van der Wielen, P. W., Jaspers, M. C., Atsma, A., de Graaf, B. and Schuren, F. (2015) 'Microbial biogeography of drinking water: patterns in phylogenetic diversity across space and time', Environmental microbiology, 17(7), pp. 2505-2514. Samuelsson, J., Payne Hallström, L., Marrone, G., & Gomes Dias, J. (2023). Legionnaires’ disease in the EU/EEA*: increasing trend from 2017 to 2019. Eurosurveillance, 28(11) Sartory, D., Spies, K., Lange, B., Schneider, S. and Langer, B. (2017) ‘Evaluation of a most probable number method for the enumeration of L. pneumophila from potable and related water samples’, Letters in Applied Microbiology, 64(4), pp. 271–275. Scaturro, M., Poznanski, E., Mupo, M., Blasior, P., Seeber, M., Prast, A.-M., Romanin, E., Girolamo, A., Rota, M. C. and Bella, A. (2020) 'Evaluation of GVPC and BCYE media for Legionella detection and enumeration in water samples by ISO 11731: does plating on BCYE medium really improve yield?', Pathogens, 9(9), pp. 757. Schleich, C., Chan, S., Pullerits, K., Besmer, M. D., Paul, C. J., Rådström, P. and Keucken, A. (2019) 'Mapping dynamics of bacterial communities in a full-scale drinking water distribution system using flow cytometry', Water, 11(10), pp. 2137. Sciences, N. A. o., Division, M., Earth, D. o., Studies, L., Health, B. o. P., Practice, P. H., Sciences, B. o. L., Science, W., Board, T. and Systems, C. o. M. o. L. i. W. (2020) Management of Legionella in water systems. National Academies Press. Sciuto, E. L., Laganà, P., Filice, S., Scalese, S., Libertino, S., Corso, D., Faro, G. and Coniglio, M. A. (2021) 'Environmental management of Legionella in domestic water systems: Consolidated and innovative approaches for disinfection methods and risk assessment', Microorganisms, 9(3), pp. 577. Segal, G., Purcell, M. and Shuman, H. A. (1998) ‘Host cell killing and bacterial conjugation require overlapping sets of genes within a 22-kb region of the L. pneumophila genome’, Proceedings of the National Academy of Sciences, 95(4), pp. 1669–1674. Shaheen, M. and Ashbolt, N. J. (2021) 'Differential bacterial predation by free-living amoebae may result in blooms of Legionella in drinking water systems', Microorganisms, 9(1), pp. 174. Shaheen, M., Scott, C. and Ashbolt, N. J. (2019) 'Long-term persistence of infectious Legionella with free-living amoebae in drinking water biofilms', International journal of hygiene and environmental health, 222(4), pp. 678-686. Stewart, C. R., Muthye, V. and Cianciotto, N. P. (2012) 'L. pneumophila persists within biofilms formed by Klebsiella pneumoniae, Flavobacterium sp., and Pseudomonas fluorescens under dynamic flow conditions', PloS one, 7(11), pp. e50560. Streich, P., Redwitz, J., Walser-Reichenbach, S., Herr, C. E., Elsner, M. and Seidel, M. (2024) 'Culture-Independent Quantification of L. pneumophila in Evaporative Cooling Systems Using Immunomagnetic Separation Coupled with Flow Cytometry', Applied Microbiology, 4(1), pp. 284-296. Sun, Z., Bai, X., Chen, X., McCrae, D. and Saaski, E. (2013) ‘A simple, specific, and rapid lateral-flow immunochromatographic test method for detection of L. pneumophila in water samples’, International Proceedings of Chemical, Biological and Environmental Engineering, 58, pp. 125–130. Surman, S., Morton, G., Keevil, B. and Fitzgeorge, R. (2001) ‘L. pneumophila proliferation is not dependent on intracellular replication’, Legionella, pp. 86–89. Tan, B., Ng, C., Nshimyimana, J. P., Loh, L. L., Gin, K. Y.-H. and Thompson, J. R. (2015) ‘Next-generation sequencing (NGS) for assessment of microbial water quality: current progress, challenges, and future opportunities’, Frontiers in Microbiology, 6, p. 1027. Tan, L. T.-H., Tee, W. Y., Khan, T. M., Ming, L. C. and Letchumanan, V. (2021) 'L. pneumophila —The causative agent of Legionnaires’ disease', Progress In Microbes & Molecular Biology, 4(1). Taylor, M., Ross, K. and Bentham, R. (2009) 'Legionella, protozoa, and biofilms: interactions within complex microbial systems', Microbial ecology, 58, pp. 538-547. Taylor, M. J., Bentham, R. H. and Ross, K. E. (2014) 'Limitations of using propidium monoazide with qPCR to discriminate between live and dead Legionella in biofilm samples', Microbiology insights, 7, pp. MBI. S17723. Temmerman, R., Vervaeren, H., Noseda, B., Boon, N. and Verstraete, W. (2006) 'Necrotrophic growth of L. pneumophila ', Applied and environmental microbiology, 72(6), pp. 4323-4328. Tewari, R., Mehta, S. and Vaishnav, P. (2019) 'Influence of microbes in cooling tower: a review', Int Res J Eng Technol, 6(8), pp. 376-383. Thomas, J. M. and Ashbolt, N. J. (2011) ‘Do free-living amoebae in treated drinking water systems present an emerging health risk?’, Environmental Science & Technology, 45(3), pp. 860–869. Thom, C., Smith, C. J., Moore, G., Weir, P. and Ijaz, U. Z. (2022) 'Microbiomes in drinking water treatment and distribution: A meta-analysis from source to tap', Water Research, 212, pp. 118106. Toplitsch, D., Platzer, S., Zehner, R., Maitz, S., Mascher, F. and Kittinger, C. (2021) 'Comparison of updated methods for Legionella detection in environmental water samples', International Journal of Environmental Research and Public Health, 18(10), pp. 5436. Tsao, H.-F., Scheikl, U., Herbold, C., Indra, A., Walochnik, J., & Horn, M. (2019). The cooling tower water microbiota: Seasonal dynamics and co-occurrence of bacterial and protist phylotypes. Water Research, 159, 464–479 Van der Kooij, D., Veenendaal, H. R. and Scheffer, W. J. (2005) ‘Biofilm formation and multiplication of Legionella in a model warm water system with pipes of copper, stainless steel and cross-linked polyethylene’, Water Research, 39(13), pp. 2789–2798. Viasus, D., Gaia, V., Manzur-Barbur, C. and Carratalà, J. (2022) 'Legionnaires’ disease: update on diagnosis and treatment', Infectious Diseases and Therapy, 11(3), pp. 973-986. Waak, M. B., LaPara, T. M., Halle, C. and Hozalski, R. M. (2018) 'Occurrence of Legionella spp. in water-main biofilms from two drinking water distribution systems', Environmental science & technology, 52(14), pp. 7630-7639. Wade, W., Spratt, D., Dymock, D. and Weightman, A. (1997) 'Molecular detection of novel anaerobic species in dentoalveolar abscesses', Clinical infectious diseases, 25(Supplement_2), pp. S235-S236. Wadowsky, R. M., Wolford, R., McNamara, A. and Yee, R. B. (1985) 'Effect of temperature, pH, and oxygen level on the multiplication of naturally occurring L. pneumophila in potable water', Applied and environmental microbiology, 49(5), pp. 1197-1205. Wales, A. D. and Davies, R. H. (2015) 'Co-selection of resistance to antibiotics, biocides and heavy metals, and its relevance to foodborne pathogens', Antibiotics, 4(4), pp. 567-604. Walker, J. T. and McDermott, P. J. (2021) 'Confirming the presence of L. pneumophila in your water system: a review of current Legionella testing methods', Journal of AOAC International, 104(4), pp. 1135-1147. Wang, H., Proctor, C. R., Edwards, M. A., Pryor, M., Santo Domingo, J. W., Ryu, H., Camper, A. K., Olson, A. and Pruden, A. (2014) 'Microbial community response to chlorine conversion in a chloraminated drinking water distribution system', Environmental science & technology, 48(18), pp. 10624-10633. Wei, C., Yu, C., Meng, J., Li, J., Li, Q. and Li, S. (2023) 'Detachable and reassemble sandwiching device with high dynamic range for multivolume droplet digital polymerase chain reactions', Sensors and Actuators B: Chemical, pp. 135013. Whiley, H. and Taylor, M. (2016) 'Legionella detection by culture and qPCR: comparing apples and oranges', Critical reviews in microbiology, 42(1), pp. 65-74. World Health Organization (WHO) (2007) Legionella and the prevention of legionellosis. Geneva: World Health Organization. Available at: https://apps.who.int/iris/handle/10665/43233 (Accessed: 19 December 2024). Yamaguchi, N., Tokunaga, Y., Goto, S., Fujii, Y., Banno, F. and Edagawa, A. (2017) 'Rapid on-site monitoring of L. pneumophila in cooling tower water using a portable microfluidic system', Scientific reports, 7(1), pp. 3092. Young, C., Smith, D., Wafer, T. and Crook, B. (2021) 'Rapid testing and interventions to control Legionella proliferation following a Legionnaires’ disease outbreak associated with cooling towers', Microorganisms, 9(3), pp. 615. Zhang, Y. and Liu, W.-T. (2019) 'The application of molecular tools to study the drinking water microbiome–Current understanding and future needs', Critical Reviews in Environmental Science and Technology, 49(13), pp. 1188-1235. Zhang, L., Fritsch, M., Hammond, L., Landini, P., & Kjelleberg, S. (2023). Understanding bacterial biofilms: From definition to treatment strategies. Frontiers in Cellular and Infection Microbiology, 13, 1137947."],"dcterms:accessrights":["public"],"dc:title":["Monitoring and Detecting Legionella within Evaporative Cooling Towers"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T23:28:51Z"}