{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:36627"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:36627","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Wireless Surgical Capsule Robots for the Gastrointestinal Tract: Towards small scale therapeutic functions without on-board computation","abstract":"Capsule robots provide an alternative route of entry to the gastrointestinal tract with minimal discomfort to patients. There are many examples of therapeutic capsules, but a gap exists in their capability in carrying out complex surgical functions such as manipulation in a suitable capsule size. There are two major factors for that limit the size of capsules; small scale actuators and on-board computation and communication required to control them. Controlling soft actuation wirelessly with an on-board pneumatic source of pressure could help with miniaturisation of efficient small scale actuators due to their scalability. An untethered robotic capsule that can provide volumetric expansion using a chemical reaction without on-board electronic components was designed along with a theoretical model for predicting the inflation behaviour. The expansion is based on the reaction between chemicals that are safe for ingestion, operated with thermal input provided by alternating magnetic fields from outside the body. Additionally, a new amplifier design that can deliver power to simple receiver circuits in parallel was presented. This allows the control of a wireless capsule that can use the electrical power for applications such as heating a target location, powering small motors bidirectionally and turn on LEDs without the use of a microcontroller. The design was tested for up to 6 addressable components, and an analysis on the limitations of this approach has been carried out. An example design of a capsule robot capable of anchoring itself to the intestinal tissues, use its manipulator arm to target a specific location and heat the location to patch wounds, or destroy pathogens or cancer cells was presented. Together, the wireless soft actuator and the wireless powering method should benefit further miniaturisation of therapeutic capsule robots capable of more complex in-vivo surgical functionality.","abstract_html":"Capsule robots provide an alternative route of entry to the gastrointestinal tract with minimal discomfort to patients. There are many examples of therapeutic capsules, but a gap exists in their capability in carrying out complex surgical functions such as manipulation in a suitable capsule size. There are two major factors for that limit the size of capsules; small scale actuators and on-board computation and communication required to control them. Controlling soft actuation wirelessly with an on-board pneumatic source of pressure could help with miniaturisation of efficient small scale actuators due to their scalability. An untethered robotic capsule that can provide volumetric expansion using a chemical reaction without on-board electronic components was designed along with a theoretical model for predicting the inflation behaviour. The expansion is based on the reaction between chemicals that are safe for ingestion, operated with thermal input provided by alternating magnetic fields from outside the body. Additionally, a new amplifier design that can deliver power to simple receiver circuits in parallel was presented. This allows the control of a wireless capsule that can use the electrical power for applications such as heating a target location, powering small motors bidirectionally and turn on LEDs without the use of a microcontroller. The design was tested for up to 6 addressable components, and an analysis on the limitations of this approach has been carried out. An example design of a capsule robot capable of anchoring itself to the intestinal tissues, use its manipulator arm to target a specific location and heat the location to patch wounds, or destroy pathogens or cancer cells was presented. Together, the wireless soft actuator and the wireless powering method should benefit further miniaturisation of therapeutic capsule robots capable of more complex in-vivo surgical functionality.","abstract_has_math":false,"creators":["Esendag, Kaan"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Damian, Dana"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-03","date_published":"2025-03","updated_at":"2026-11-18T23:29:21Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/M508135/1"],"render_values":[{"text":"EP/M508135/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000233523735"],"render_values":[{"text":"0000-0002-3352-3735","href":"https://orcid.org/0000-0002-3352-3735","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/36627/1/KaanEsendag_ThesisFinal.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A36627","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Damian, Dana"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC DTP Early Career Researcher Scholarship"]},{"key":"dc:creator","label":"Author","values":["Esendag, Kaan"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000233523735"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-03"]},{"key":"dc:date.issued","label":"Date","values":["2025-03"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Automatic Control and Systems Engineering (Sheffield)","Electronic and Electrical Engineering (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/36627/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] M. Simi, G. Gerboni, A. Menciassi, and P. Valdastri, “Magnetic torsion springmechanism for a wireless biopsy capsule,” Journal of Medical Devices, vol. 7, no. 4,p. 041009, 09 2013. [Online]. Available: https://doi.org/10.1115/1.4025185 [2] D. Ye, J. Xue, S. Yuan, F. Zhang, S. Song, J. Wang, and M. Q.-H. Meng, “Designand control of a magnetically-actuated capsule robot with biopsy function,” IEEETransactions on Biomedical Engineering, vol. 69, no. 9, pp. 2905–2915, 2022. [3] Z. Nagy, R. Oung, J. J. Abbott, and B. J. Nelson, “Experimental investigation of magneticself-assembly for swallowable modular robots,” in 2008 IEEE/RSJ InternationalConference on Intelligent Robots and Systems, 2008, pp. 1915–1920. [4] L. Yan, T. Wang, D. Liu, J. Peng, Z. Jiao, and C.-Y. Chen, “Capsule robot forobesity treatment with wireless powering and communication,” IEEE Transactions onIndustrial Electronics, vol. 62, no. 2, pp. 1125–1133, 2015. [5] Y. Tang, M. Li, T. Wang, X. Dong, W. Hu, and M. Sitti, “Wireless miniature magneticphase-change soft actuators,” Advanced Materials, 2022. [6] M. Boyvat, D. M. Vogt, and R. J. Wood, “Ultrastrong and high-strokewireless soft actuators through liquid-gas phase change,” Advanced MaterialsTechnologies, vol. 4, no. 2, p. 1800381, 2019. [Online]. Available: https://onlinelibrary.wiley.com/doi/abs/10.1002/admt.201800381 [7] S. Wu, Y. Hong, Y. Zhao, J. Yin, and Y. Zhu, “Caterpillar-inspired softcrawling robot with distributed programmable thermal actuation,” ScienceAdvances, vol. 9, no. 12, p. eadf8014, 2023. [Online]. Available: https://www.science.org/doi/abs/10.1126/sciadv.adf8014 [8] M. E. M. K. Abdelaziz, J. Zhao, B. G. Rosa, H.-T. Lee, D. Simon, K. Vyas,B. Li, H. Koguna, Y. Li, A. A. Demircali, H. Uvet, G. Gencoglan, A. Akcay,M. Elriedy, J. Kinross, R. Dasgupta, Z. Takats, E. Yeatman, G.-Z. Yang, andB. Temelkuran, “Fiberbots: Robotic fibers for high-precision minimally invasivesurgery,” Science Advances, vol. 10, no. 3, p. eadj1984, 2024. [Online]. Available:https://www.science.org/doi/abs/10.1126/sciadv.adj1984 [9] M. S. M. Ali and K. Takahata, “Wireless microfluidic control with integratedshape-memory-alloy actuators operated by field frequency modulation,” Journal ofMicromechanics and Microengineering, vol. 21, no. 7, p. 075005, jun 2011. [Online].Available: https://dx.doi.org/10.1088/0960-1317/21/7/075005 [10] W. Chen, J. Sui, and C. Wang, “Magnetically actuated capsule robots: A review,”IEEE Access, vol. 10, pp. 88 398–88 420, 2022. [11] R. L. Siegel, K. D. Miller, N. S. Wagle, and A. Jemal, “Cancer statistics, 2023,” CA: ACancer Journal for Clinicians, vol. 73, no. 1, pp. 17–48, 2023. [Online]. Available:https://acsjournals.onlinelibrary.wiley.com/doi/abs/10.3322/caac.21763 [12] M. F. Hale, R. Sidhu, and M. E. McAlindon, “Capsule endoscopy: current practice andfuture directions,” World journal of gastroenterology, vol. 20, no. 24, pp. 7752–7759,Jun 2014. [13] S. N. Adler and Y. C. Metzger, “PillCam COLON capsule endoscopy: recent advancesand new insights,” Therapeutic Advances in Gastroenterology, vol. 4, no. 4, pp. 265–268, Jul. 2011. [14] N. K. Mandsberg, J. F. Christfort, K. Kamguyan, A. Boisen, and S. K. Srivastava,“Orally ingestible medical devices for gut engineering,” Advanced Drug DeliveryReviews, vol. 165-166, pp. 142–154, 2020. [15] H.-L. Ching, M. F. Hale, and M. E. McAlindon, “Current and future role ofmagnetically assisted gastric capsule endoscopy in the upper gastrointestinal tract,”Therapeutic Advances in Gastroenterology, vol. 9, no. 3, pp. 313–321, 2016, pMID:27134661. [Online]. Available: https://doi.org/10.1177/1756283X16633052 [16] S. Yim and M. Sitti, “Shape-programmable soft capsule robots for semi-implantabledrug delivery,” IEEE Transactions on Robotics, vol. 28, no. 5, pp. 1198–1202, 2012. [17] W. Yu, R. Rahimi, M. Ochoa, R. Pinal, and B. Ziaie, “A smart capsule with gi-tractlocation-specific payload release,” IEEE Transactions on Biomedical Engineering,vol. 62, no. 9, pp. 2289–2295, 2015. [18] O. Erin, M. Boyvat, J. Lazovic, M. E. Tiryaki, and M. Sitti, “Wireless mri-poweredreversible orientation-locking capsule robot,” Advanced Science, vol. 8, no. 13, p.2100463, 2021. [Online]. Available: https://onlinelibrary.wiley.com/doi/abs/10.1002/advs.202100463 [19] V. H. Le, H. L. Rodriguez, C. Lee, G. Go, J. Zhen, V. D. Nguyen, H. Choi, S. Y.Ko, J.-O. Park, and S. Park, “A soft-magnet-based drug-delivery module for activelocomotive intestinal capsule endoscopy using an electromagnetic actuation system,”Sensors and Actuators A: Physical, vol. 243, pp. 81–89, 2016. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S0924424716301194 [20] M. Beccani, G. Aiello, N. Gkotsis, H. Tunc, A. Taddese, E. Susilo,P. Völgyesi, Ákos Lédeczi, E. D. Momi, and P. Valdastri, “Componentbased design of a drug delivery capsule robot,” Sensors and ActuatorsA: Physical, vol. 245, pp. 180–188, 2016. [Online]. Available: https://www.sciencedirect.com/science/article/pii/S0924424716301807 [21] M. Rehan, I. Al-Bahadly, D. G. Thomas, W. Young, L. K. Cheng, andE. Avci, “Smart capsules for sensing and sampling the gut: status, challengesand prospects,” Gut, vol. 73, no. 1, pp. 186–202, 2024. [Online]. Available:https://gut.bmj.com/content/73/1/186 [22] Y. L. Kong, X. Zou, C. A. McCandler, A. R. Kirtane, S. Ning, J. Zhou, A. Abid,M. Jafari, J. Rogner, D. Minahan, J. E. Collins, S. McDonnell, C. Cleveland, T. Bensel,S. Tamang, G. Arrick, A. Gimbel, T. Hua, U. Ghosh, V. Soares, N. Wang, A. Wahane,A. Hayward, S. Zhang, B. R. Smith, R. Langer, and G. Traverso, “3d-printed gastricresident electronics,” Advanced Materials Technologies, vol. 4, no. 3, p. 1800490,2019. [23] V. H. Le, V. D. Nguyen, C. Lee, G. Go, J.-O. Park, and S. Park,“Miniaturized biopsy module using gripper tool for active locomotive capsuleendoscope,” Mechatronics, vol. 44, pp. 52–59, 2017. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S0957415817300582 [24] D. Ye, F. Zhang, S. Yuan, S. Song, and M. Q.-H. Meng, “Magnetically driven wirelesscapsule robot with targeting biopsy function,” in 2019 IEEE International Conferenceon Robotics and Biomimetics (ROBIO), 2019, pp. 1222–1227. [25] M. Rehan, I. Al-Bahadly, D. G. Thomas, and E. Avci, “Development of a roboticcapsule for in vivo sampling of gut microbiota,” IEEE Robotics and AutomationLetters, vol. 7, no. 4, pp. 9517–9524, 2022. [26] H. Rezaei Nejad, B. C. M. Oliveira, A. Sadeqi, A. Dehkharghani, I. Kondova,J. A. M. Langermans, J. S. Guasto, S. Tzipori, G. Widmer, and S. R. Sonkusale,“Ingestible osmotic pill for in vivo sampling of gut microbiomes,” AdvancedIntelligent Systems, vol. 1, no. 5, p. 1900053, 2019. [Online]. Available:https://onlinelibrary.wiley.com/doi/abs/10.1002/aisy.201900053 [27] F. Munoz, G. Alici, and W. Li, “A review of drug delivery systems for capsuleendoscopy,” Advanced Drug Delivery Reviews, vol. 71, pp. 77–85, 2014. [28] S. Song, S. Yuan, F. Zhang, J. Su, D. Ye, J. Wang, and M. Q.-H. Meng, “Integrateddesign and decoupled control of anchoring and drug release for wireless capsulerobots,” IEEE/ASME Transactions on Mechatronics, vol. 27, no. 5, pp. 2897–2907,2022. [29] J. Gao and G. Yan, “Design and implementation of a clamper-based and motor-drivencapsule robot powered by wireless power transmission,” IEEE Access, vol. 7, pp.138 151–138 161, 2019. [30] W. Chen, Q. Ke, S. He, W. Luo, X. C. Ji, and G. Yan, “Experimental research onanchoring force in intestine for the motion of capsule robot,” Journal of MedicalEngineering and Technology, vol. 37, no. 5, pp. 334–341, 2013. [31] B. H. K. Leung, C. C. Y. Poon, R. Zhang, Y. Zheng, C. K. W. Chan, P. W. Y. Chiu,J. Y. W. Lau, and J. J. Y. Sung, “A therapeutic wireless capsule for treatment ofgastrointestinal haemorrhage by balloon tamponade effect,” IEEE Transactions onBiomedical Engineering, vol. 64, no. 5, pp. 1106–1114, 2017. [32] J. A. Vale, P. D. Miller, and R. S. Kirby, “Balloon dilatation of the prostate–shouldit have a place in the urologist’s armamentarium?” J R Soc Med, vol. 86, no. 2, pp.83–86, Feb. 1993. [33] K. Sunada, H. Yamamoto, H. Kita, T. Yano, H. Sato, Y. Hayashi, T. Miyata, Y. Sekine,A. Kuno, M. Iwamoto, H. Ohnishi, K. Ido, and K. Sugano, “Clinical outcomes ofenteroscopy using the double-balloon method for strictures of the small intestine,”World J Gastroenterol, vol. 11, no. 7, pp. 1087–1089, Feb. 2005. [34] Pasricha, T. Smith, B. F. ; Mitchell, V. R. ; Fang, B. Brooks, E. R. ; Gerding, J. S.; Washington, M. K. Valdastri, P. Obstein, and K. L., “Controlled colonic insufflationby a remotely triggered capsule for improved mucosal visualization,” Endoscopy,vol. 46, no. 07, pp. 614–618, Jun. 2014. [35] P. Valdastri, M. Simi, and R. J. Webster, 3rd, “Advanced technologies for gastrointestinalendoscopy,” The Annual Reviews of Biomedical Engineering, vol. 14, pp. 397–429,May 2012. [36] M. Adami and A. Seibel, “On-board pneumatic pressure generation methods for softrobotics applications,” Actuators, vol. 8, no. 1, 2019. [37] A. L. Evenchik, A. Q. Kane, E. Oh, and R. L. Truby, “Electrically controllablematerials for soft, bioinspired machines,” Annual Review of Materials Research,vol. 53, no. Volume 53, 2023, pp. 225–251, 2023. [Online]. Available: https://www.annualreviews.org/content/journals/10.1146/annurev-matsci-080921-102916 [38] J. Jung, S. Shin, M. Li, and Y. T. Kim, “Telemetry transmission to support bidirectionalcommunication for capsule endoscope using human body communication,” IEEEMicrowave and Wireless Components Letters, vol. 31, no. 7, pp. 905–908, 2021. [39] R. Fontana, F. Mulana, C. Cavallotti, G. Tortora, M. Vigliar, M. Vatteroni, andA. Menciassi, “An innovative wireless endoscopic capsule with spherical shape,” IEEETransactions on Biomedical Circuits and Systems, vol. 11, no. 1, pp. 143–152, 2017. [40] M. J. Christoe, J. Yuan, A. Michael, and K. Kalantar-Zadeh, “Bluetooth signal attenuationanalysis in human body tissue analogues,” IEEE Access, vol. 9, pp. 85 144–85 150,2021. [41] J. H. Palep, “Robotic assisted minimally invasive surgery,” Journal of Minimal AccessSurgery, vol. 5, no. 1, pp. 1–7, Jan. 2009. [42] J. Huang, Z. Zhang, and S. Wang, “Efficacy of the da vinci surgicalsystem in colorectal surgery comparing with traditional laparoscopic surgery oropen surgery: A meta-analysis,” International Journal of Advanced RoboticSystems, vol. 13, no. 5, p. 1729881416664849, 2016. [Online]. Available:https://doi.org/10.1177/1729881416664849 [43] T. Haidegger, S. Speidel, D. Stoyanov, and R. M. Satava, “Robot-assisted minimallyinvasive surgery—surgical robotics in the data age,” Proceedings of the IEEE, vol.110, no. 7, pp. 835–846, 2022. [44] A. R. Lanfranco, A. E. Castellanos, J. P. Desai, and W. C. Meyers, “Robotic surgery:a current perspective,” Annals of Surgery, vol. 239, no. 1, pp. 14–21, Jan. 2004. [45] D. Jain, A. Goyal, and S. Zavala, “Predicting colonoscopy time: A quality improvementinitiative,” Clinical Endoscopy, vol. 49, no. 6, pp. 555–559, 2016. [46] H. Kang and M. H. Thoufeeq, “Size of colorectal polyps determines time takento remove them endoscopically,” Endoscopy International Open, vol. 6, no. 5, pp.E610–E615, 2018. [47] U. Akyuz and F. Akyuz, “Diagnostic and therapeutic capability of Double-Balloonenteroscopy in clinical practice,” Clin Endosc, vol. 49, no. 2, pp. 157–160, Mar. 2016. [48] S. R. Lieber, B. J. Heller, C. F. Martin, C.W. Howard, and S. Crockett, “Complicationsof anesthesia services in gastrointestinal endoscopic procedures,” ClinicalGastroenterology and Hepatology, vol. 18, no. 9, pp. 2118–2127.e4, 2020. [Online].Available: https://www.sciencedirect.com/science/article/pii/S1542356519311103 [49] R. M. Bonnor and K. A. Ludwig, “Laparoscopic colectomy for colon cancer: comparableto conventional oncologic surgery?” Clin. Colon Rectal Surg., vol. 18, no. 3, pp.174–181, aug 2005. [50] K. Wang, J. Ma, F. Wang, Z. Wang, G. Yan, and Y. Zhou, “Full-driving soft roboticcolonoscope in compliant colon tissue,” J. Med. Eng. Technol., vol. 41, no. 8, pp.662–669, Nov. 2017. [51] C. J. Fyock and P. V. Draganov, “Colonoscopic polypectomy and associated techniques,”World journal of gastroenterology, vol. 16, no. 29, pp. 3630–3637, 2010. [52] L. Liu, S. Towfighian, and A. Hila, “A review of locomotion systems for capsuleendoscopy,” IEEE Reviews in Biomedical Engineering, vol. 8, pp. 138–151, 2015. [53] H. F. Helander and L. Fändriks, “Surface area of the digestive tract - revisited,”Scandinavian Journal of Gastroenterology, vol. 49, no. 6, pp. 681–689, 2014. [54] G. Kiran, I. Yilmaz, S. Aydin, F. Sanlikan, and E. Ozkaya, “The shortest distancebetween the skin and the peritoneal cavity is obtained with fascial elevation: a preliminaryprospective laparoscopic entry study,” Facts Views Vis Obgyn, vol. 14, no. 2, pp.171–175, Jun. 2022. [55] A. E. Deatsch and B. A. Evans, “Heating efficiency in magnetic nanoparticle hyperthermia,”Journal of Magnetism and Magnetic Materials, vol. 354, pp. 163–172,2014. [56] A. Bhardwaj, K. Parekh, and N. Jain, “In vitro hyperthermic effect of magnetic fluidon cervical and breast cancer cells,” Scientific Reports, vol. 10, no. 1, p. 15249, Sep2020. [57] P. R. Slawinski, K. L. Obstein, and P. Valdastri, “Capsule endoscopy of the future:What’s on the horizon?” World J Gastroenterol, vol. 21, no. 37, pp. 10 528–10 541,Oct. 2015. [58] Q. Cao, R. Deng, Y. Pan, R. Liu, Y. Chen, G. Gong, J. Zou, H. Yang, and D. Han,“Robotic wireless capsule endoscopy: recent advances and upcoming technologies,”Nature Communications, vol. 15, no. 1, p. 4597, May 2024. [Online]. Available:https://doi.org/10.1038/s41467-024-49019-0 [59] A. Z. Taddese, P. R. Slawinski, K. L. Obstein, and P. Valdastri, “Closed loop controlof a tethered magnetic capsule endoscope,” Robot Sci Syst, vol. 2016, Jun. 2016. [60] S. Miyashita, S. Guitron, K. Yoshida, S. Li, D. D. Damian, and D. Rus, “Ingestible,controllable, and degradable origami robot for patching stomach wounds,” in 2016IEEE International Conference on Robotics and Automation (ICRA), 2016, pp. 909–916. [61] A. du Plessis d’Argentré, S. Perry, Y. Iwata, H. Iwasaki, E. Iwase, A. Fabozzo, I. Will,D. Rus, D. D. Damian, and S. Miyashita, “Programmable medicine: Autonomous,ingestible, deployable hydrogel patch and plug for stomach ulcer therapy,” in 2018IEEE International Conference on Robotics and Automation (ICRA), 2018, pp. 1511–1518. [62] Y. Shi, G. Yan, W. Chen, and B. Zhu, “Micro-intestinal robot withwireless power transmission: design, analysis and experiment,” Computersin Biology and Medicine, vol. 66, pp. 343–351, 2015. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S0010482515002036 [63] K. Wang, G. Yan, G. Ma, and D. Ye, “An earthworm-like robotic endoscopesystem for human intestine: Design, analysis, and experiment,” Annals ofBiomedical Engineering, vol. 37, no. 1, pp. 210–221, Jan 2009. [Online]. Available:https://doi.org/10.1007/s10439-008-9597-6 [64] R. A. Ganz, J. Viveiros, A. Ahmad, A. Ahmadi, A. Khalil, M. J. Tolkoff, N. S.Nishioka, and M. R. Hamblin, “Helicobacter pylori in patients can be killed by visiblelight,” Lasers in Surgery and Medicine, vol. 36, no. 4, pp. 260–265, 2005. [Online].Available: https://onlinelibrary.wiley.com/doi/abs/10.1002/lsm.20161 [65] G. Tortora, B. Orsini, P. Pecile, A. Menciassi, F. Fusi, and G. Romano, “An ingestiblecapsule for the photodynamic therapy of helicobacter pylori infection,” IEEE/ASMETransactions on Mechatronics, vol. 21, no. 4, pp. 1935–1942, 2016. [66] Q. Tang, G. Jin, G. Wang, T. Liu, X. Liu, B. Wang, and H. Cao, “Currentsampling methods for gut microbiota: A call for more precise devices,”Frontiers in Cellular and Infection Microbiology, vol. 10, 2020. [Online].Available: https://www.frontiersin.org/journals/cellular-and-infection-microbiology/articles/10.3389/fcimb.2020.00151 [67] J. Wang, M. Leach, E. G. Lim, Z. Wang, R. Pei, and Y. Huang, “An implantable andconformal antenna for wireless capsule endoscopy,” IEEE Antennas and WirelessPropagation Letters, vol. 17, no. 7, pp. 1153–1157, 2018. [68] P. R. Slawinski, K. L. Obstein, and P. Valdastri, “Emerging issues and future developmentsin capsule endoscopy,” Techniques in Gastrointestinal Endoscopy, vol. 17,no. 1, pp. 40–46, 2015. [69] B. Boyd, K. Esendag, S. Miyashita, and D. D. Damian, “Development of a nearfieldwireless power transfer system for controlling electronic motors within capsuleendoscopes,” in Hamlyn Symposium on Medical Robotics 2024, vol. 16, June 2024,pp. 95–96. [70] Z. Li, M. C. Hoang, C.-S. Kim, E. Choi, D. Bang, J.-O. Park, and B. Kang, “Modularcapsules with assembly and separation mechanism: Proof of concept,” Actuators,vol. 10, no. 7, 2021. [Online]. Available: https://www.mdpi.com/2076-0825/10/7/159 [71] F. Peker and O. Ferhano˘glu, “Multi-capsule endoscopy: An initial study on modelingand phantom experimentation of a magnetic capsule train,” Journal of Medical andBiological Engineering, vol. 41, no. 3, pp. 315–321, Jun 2021. [Online]. Available:https://doi.org/10.1007/s40846-021-00610-6 [72] J. Guo, P. Liu, S. Guo, L. Wang, and G. Sun, “Development of a novel wireless spiralcapsule robot with modular structure,” in 2017 IEEE International Conference onMechatronics and Automation (ICMA), 2017, pp. 439–444. [73] X. Ma, D. E. Vogtmann, and S. Bergbreiter, “Dynamics and scaling ofmagnetically folding multi-material structures,” 2016 IEEE International Conferenceon Robotics and Automation (ICRA), pp. 1899–1906, 2016. [Online]. Available:https://api.semanticscholar.org/CorpusID:17929579 [74] H. Suzuki and R. J. Wood, “Origami-inspired miniature manipulator for teleoperatedmicrosurgery,” Nature Machine Intelligence, vol. 2, no. 8, pp. 437–446, 2020. [75] J. Liu, X. Chen, Q. Lahondes, K. Esendag, D. Damian, and S. Miyashita, “Origamirobot self-folding by magnetic induction,” in 2022 IEEE/RSJ International Conferenceon Intelligent Robots and Systems (IROS), 2022, pp. 2519–2525. [76] J. Han, D. Rus, and S. Miyashita, “Roblets: Robotic tablets that self-assemble andself-fold into a robot,” in 2023 IEEE/RSJ International Conference on IntelligentRobots and Systems (IROS), 2023, pp. 4709–4714. [77] M. P. Kummer, J. J. Abbott, B. E. Kratochvil, R. Borer, A. Sengul, and B. J. Nelson,“Octomag: An electromagnetic system for 5-dof wireless micromanipulation,” IEEETransactions on Robotics, vol. 26, no. 6, pp. 1006–1017, 2010. [78] K. Esendag, M. E. McAlindon, D. Rus, S. Miyashita, and D. D. Damian, “Developmentof an untethered inflatable capsule robot for stricture dilation - a preliminary study,” inHamlyn Symposium on Medical Robotics 2023, vol. 15, June 2023, pp. 101–102. [79] O. Onaizah and E. Diller, “Tetherless mobile micro-surgical scissors using magneticactuation,” in 2019 International Conference on Robotics and Automation (ICRA),2019, pp. 894–899. [80] A. Lim, A. Schonewille, C. Forbrigger, T. Looi, J. Drake, and E. Diller, “Designand comparison of magnetically-actuated dexterous forceps instruments for neuroendoscopy,”IEEE Transactions on Biomedical Engineering, vol. 68, no. 3, pp. 846–856,2021. [81] S. Guitron, A. Guha, S. Li, and D. Rus, “Autonomous locomotion of a miniature,untethered origami robot using hall effect sensor-based magnetic localization,” in2017 IEEE International Conference on Robotics and Automation (ICRA), 2017, pp.4807–4813. [82] J. Liu, H. Sugiyama, T. Nakayama, and S. Miyashita, “Magnetic sensor based topographiclocalization for automatic dislocation of ingested button battery,” in 2020 IEEEInternational Conference on Robotics and Automation (ICRA), 2020, pp. 5488–5494. [83] D. Wang, B. Zhao, X. Li, L. Dong, M. Zhang, J. Zou, and G. Gu, “Dexterouselectrical-driven soft robots with reconfigurable chiral-lattice foot design,” NatureCommunications, vol. 14, no. 1, p. 5067, Aug 2023. [Online]. Available:https://doi.org/10.1038/s41467-023-40626-x [84] A. Wiranata, M. Kanno, N. Chiya, H. Okabe, T. Horii, T. Fujie, N. Hosoya, andS. Maeda, “High-frequency oscillations of low-voltage dielectric elastomer actuators,”Applied Physics Express, vol. 15, 12 2021. [85] S. Rahmanian, A. Alibakhshi, H. Mouharrar, J. M. Benitez, and F. J. Montáns, “Lowvoltagedielectric elastomer actuators by electro-mechanical resonance syntonization,”International Journal of Mechanical Sciences, vol. 263, p. 108758, 2024. [Online].Available: https://www.sciencedirect.com/science/article/pii/S0020740323006604 [86] S. Wu, G. L. Baker, J. Yin, and Y. Zhu, “Fast thermal actuators for soft robotics,” SoftRobotics, vol. 9, no. 6, pp. 1031–1039, 2022, pMID: 34874763. [Online]. Available:https://doi.org/10.1089/soro.2021.0080 [87] Y. Wu, J. K. Yim, J. Liang, Z. Shao, M. Qi, J. Zhong, Z. Luo, X. Yan, M. Zhang,X. Wang, R. S. Fearing, R. J. Full, and L. Lin, “Insect-scale fast moving andultrarobust soft robot,” Science Robotics, vol. 4, no. 32, p. eaax1594, 2019. [Online].Available: https://www.science.org/doi/abs/10.1126/scirobotics.aax1594 [88] S. M. Felton, K. P. Becker, D. M. Aukes, and R. J. Wood, “Self-folding withshape memory composites at the millimeter scale,” Journal of Micromechanicsand Microengineering, vol. 25, no. 8, p. 085004, jul 2015. [Online]. Available:https://dx.doi.org/10.1088/0960-1317/25/8/085004 [89] N. Sabahi, W. Chen, C.-H. Wang, J. J. Kruzic, and X. Li, “A review onadditive manufacturing of shape-memory materials for biomedical applications,”JOM, vol. 72, no. 3, pp. 1229–1253, Mar 2020. [Online]. Available:https://doi.org/10.1007/s11837-020-04013-x [90] M.-S. Kim, J.-K. Heo, H. Rodrigue, H.-T. Lee, S. Pané, M.-W. Han, and S.-H.Ahn, “Shape memory alloy (sma) actuators: The role of material, form, and scalingeffects,” Advanced Materials, vol. 35, no. 33, p. 2208517, 2023. [Online]. Available:https://onlinelibrary.wiley.com/doi/abs/10.1002/adma.202208517 [91] W. Huang, Z. Ding, C. Wang, J. Wei, Y. Zhao, and H. Purnawali, “Shape memorymaterials,” Materials Today, vol. 13, no. 7, pp. 54–61, 2010. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S1369702110701280 [92] K. Wang, H. Si, Q. Wan, Z. Wang, A. Qin, and B. Z. Tang, “Luminescenttwo-way reversible shape memory polymers prepared by hydroxyl–yne clickpolymerization,” J. Mater. Chem. C, vol. 8, pp. 16 121–16 128, 2020. [Online].Available: http://dx.doi.org/10.1039/D0TC03888A [93] R. Regmi, S. R. Bhattarai, C. Sudakar, A. S. Wani, R. Cunningham, P. P. Vaishnava,R. Naik, D. Oupicky, and G. Lawes, “Hyperthermia controlled rapid drug releasefrom thermosensitive magnetic microgels,” J. Mater. Chem., vol. 20, pp. 6158–6163,2010. [Online]. Available: http://dx.doi.org/10.1039/C0JM00844C [94] F. G. Downs, D. J. Lunn, M. J. Booth, J. B. Sauer, W. J. Ramsay, R. G. Klemperer,C. J. Hawker, and H. Bayley, “Multi-responsive hydrogel structures from patterneddroplet networks,” Nature Chemistry, vol. 12, no. 4, pp. 363–371, Apr 2020. [Online].Available: https://doi.org/10.1038/s41557-020-0444-1 [95] Y. S. Kim, M. Liu, Y. Ishida, Y. Ebina, M. Osada, T. Sasaki, T. Hikima, M. Takata,and T. Aida, “Thermoresponsive actuation enabled by permittivity switching inan electrostatically anisotropic hydrogel,” Nature Materials, vol. 14, no. 10, pp.1002–1007, Oct 2015. [Online]. Available: https://doi.org/10.1038/nmat4363 [96] M. Santhamoorthy, T. T. Vy Phan, V. Ramkumar, C. J. Raorane, K. Thirupathi,and S.-C. Kim, “Thermo-sensitive poly (n-isopropylacrylamide-co-polyacrylamide)hydrogel for ph-responsive therapeutic delivery,” Polymers, vol. 14, no. 19, 2022.[Online]. Available: https://www.mdpi.com/2073-4360/14/19/4128 [97] S. M. Mirvakili and R. Langer, “Wireless on-demand drug delivery,” Nature Electronics,vol. 4, no. 7, pp. 464–477, 2021. [98] C. Löwenberg, M. Balk, C. Wischke, M. Behl, and A. Lendlein, “Shape-memoryhydrogels: Evolution of structural principles to enable shape switching of hydrophilicpolymer networks,” Accounts of Chemical Research, vol. 50, no. 4, pp. 723–732,2017. [Online]. Available: https://doi.org/10.1021/acs.accounts.6b00584 [99] A. Razmjou, M. R. Barati, G. P. Simon, K. Suzuki, and H. Wang, “Fast deswelling ofnanocomposite polymer hydrogels via magnetic field-induced heating for emerging fodesalination,” Environmental Science & Technology, vol. 47, no. 12, pp. 6297–6305,2013, pMID: 23663180. [Online]. Available: https://doi.org/10.1021/es4005152 [100] Y. Liu, B. Shaw, M. D. Dickey, and J. Genzer, “Sequential self-folding of polymersheets,” Science Advances, vol. 3, no. 3, p. e1602417, 2017. [Online]. Available:https://www.science.org/doi/abs/10.1126/sciadv.1602417 [101] M. Boyvat and M. Sitti, “Remote modular electronics for wireless magneticdevices,” Advanced Science, vol. 8, no. 17, p. 2101198, 2021. [Online]. Available:https://onlinelibrary.wiley.com/doi/abs/10.1002/advs.202101198 [102] J. Baltrusaitis and V. H. Grassian, “Carbonic acid formation from reaction of carbondioxide and water coordinated to al(oh)3: A quantum chemical study,” The Journal ofPhysical Chemistry A, vol. 114, no. 6, pp. 2350–2356, 2010. [103] V. Vallem, E. Roosa, T. Ledinh, S. Rashid Nadimi, A. Kiani, and M. D. Dickey,“Soft electrochemical bubble actuator with liquid metal electrode using an embodiedhydrogel pneumatic source,” Soft Matter, vol. 18, pp. 9291–9298, 2022. [Online].Available: http://dx.doi.org/10.1039/D2SM00874B [104] S. M. Mirvakili, D. Sim, I. W. Hunter, and R. Langer, “Actuation of untetheredpneumatic artificial muscles and soft robots using magnetically induced liquid-to-gasphase transitions,” Science Robotics, vol. 5, no. 41, 2020. [105] S. Hirai, T. Nagatomo, T. Hiraki, H. Ishizuka, Y. Kawahara, and N. Miki, “Microelastic pouch motors: Elastically deformable and miniaturized soft actuators usingliquid-to-gas phase change,” IEEE Robotics and Automation Letters, vol. 6, no. 3, pp.5373–5380, 2021. [106] S. T. Brittain, O. J. A. Schueller, H. Wu, S. Whitesides, and G. M. Whitesides,“Microorigami: Fabrication of small, three-dimensional, metallic structures,” TheJournal of Physical Chemistry B, vol. 105, no. 2, pp. 347–350, 2001. [Online].Available: https://doi.org/10.1021/jp002556e [107] T. Tachi, “Origamizer,” 2010, accessed on October 31, 2024. [Online]. Available:www.tsg.ne.jp/TT/software/ [108] ——, “Origamizing polyhedral surfaces,” IEEE transactions on visualization andcomputer graphics, vol. 16, pp. 298–311, 03 2010. [109] E. D. Demaine, M. L. Demaine, D. Koschitz, and T. Tachi, “Curved crease folding- a review on art, design and mathematics,” in Semantic Scholar, 2011. [Online].Available: https://api.semanticscholar.org/CorpusID:15416501 [110] N. Benbernou, E. D. Demaine, M. L. Demaine, and A. Ovadya, “A universalcrease pattern for folding orthogonal shapes,” 2009. [Online]. Available:https://arxiv.org/abs/0909.5388 [111] T. Tachi, “3d origami design based on tucking molecule,” in Semantic Scholar, 2008.[Online]. Available: https://api.semanticscholar.org/CorpusID:15986677 [112] A. Yellowhorse and L. L. Howell, “Creating rigid foldability to enable mobility oforigami-inspired mechanisms,” Journal of Mechanisms and Robotics, vol. 8, no. 1, p.011011, 08 2015. [Online]. Available: https://doi.org/10.1115/1.4029923 [113] K. Miura, “Method of packaging and deployment of large membranes in space,”in Semantic Scholar, 1985. [Online]. Available: https://api.semanticscholar.org/CorpusID:109375609 [114] D. Rus and M. T. Tolley, “Design, fabrication and control of origami robots,” NatureReviews Materials, vol. 3, no. 6, pp. 101–112, Jun 2018. [Online]. Available:https://doi.org/10.1038/s41578-018-0009-8 [115] D. A. McAdams and W. Li, “A novel method to design and optimize flat-foldableorigami structures through a genetic algorithm,” Journal of Computing andInformation Science in Engineering, vol. 14, no. 3, p. 031008, 06 2014. [Online].Available: https://doi.org/10.1115/1.4026509 [116] J. T. Overvelde, T. A. de Jong, Y. Shevchenko, S. A. Becerra, G. M. Whitesides,J. C. Weaver, C. Hoberman, and K. Bertoldi, “A three-dimensional actuatedorigami-inspired transformable metamaterial with multiple degrees of freedom,”Nature Communications, vol. 7, no. 1, p. 10929, Mar 2016. [Online]. Available:https://doi.org/10.1038/ncomms10929 [117] S. Wu, Q. Ze, J. Dai, N. Udipi, G. H. Paulino, and R. Zhao, “Stretchable origamirobotic arm with omnidirectional bending and twisting,” Proceedings of the NationalAcademy of Sciences, vol. 118, no. 36, p. e2110023118, 2021. [Online]. Available:https://www.pnas.org/doi/abs/10.1073/pnas.2110023118 [118] J. Liu, X. Chen, Q. Lahondes, K. Esendag, D. Damian, and S. Miyashita, “Origamirobot self-folding by magnetic induction,” in 2022 IEEE/RSJ International Conferenceon Intelligent Robots and Systems (IROS), 2022, pp. 2519–2525. [119] S. Miyashita, S. Guitron, M. Ludersdorfer, C. R. Sung, and D. Rus, “An untetheredminiature origami robot that self-folds, walks, swims, and degrades,” in 2015 IEEEInternational Conference on Robotics and Automation (ICRA), 2015, pp. 1490–1496. [120] K. Zhu, H. Nii, O. N. N. Fernando, and A. D. Cheok, “Selective inductivepowering system for paper computing,” in Proceedings of the 8th InternationalConference on Advances in Computer Entertainment Technology, ser. ACE ’11. NewYork, NY, USA: Association for Computing Machinery, 2011. [Online]. Available:https://doi.org/10.1145/2071423.2071497 [121] M. Boyvat, J.-S. Koh, and R. J. Wood, “Addressable wireless actuation for multijointfolding robots and devices,” Science Robotics, vol. 2, no. 8, p. eaan1544, 2017.[Online]. Available: https://www.science.org/doi/abs/10.1126/scirobotics.aan1544 [122] J. O. Jacobsen, B. G. Winder, L. L. Howell, and S. P. Magleby, “Lamina emergentmechanisms and their basic elements,” Journal of Mechanisms and Robotics, vol. 2,no. 1, p. 011003, 11 2009. [Online]. Available: https://doi.org/10.1115/1.4000523 [123] P. S. Gollnick, S. P. Magleby, and L. L. Howell, “An introduction to multilayer laminaemergent mechanisms,” Journal of Mechanical Design, vol. 133, no. 8, p. 081006, 082011. [Online]. Available: https://doi.org/10.1115/1.4004542 [124] I. L. Delimont, S. P. Magleby, and L. L. Howell, “Evaluating complianthinge geometries for origami-inspired mechanisms,” Journal of Mechanismsand Robotics, vol. 7, no. 1, p. 011009, 02 2015. [Online]. Available:https://doi.org/10.1115/1.4029325 [125] H. Shigemune, S. Maeda, Y. Hara, and S. Hashimoto, “Design of paper mechatronics:Towards a fully printed robot,” in 2014 IEEE/RSJ International Conference onIntelligent Robots and Systems, 2014, pp. 536–541. [126] H. Shigemune, S. Maeda, Y. Hara, N. Hosoya, and S. Hashimoto, “Origami robot:A self-folding paper robot with an electrothermal actuator created by printing,”IEEE/ASME Transactions on Mechatronics, vol. 21, no. 6, pp. 2746–2754, 2016. [127] Y. Li, R. Torah, S. Beeby, and J. Tudor, “An all-inkjet printed flexible capacitor on atextile using a new poly(4-vinylphenol) dielectric ink for wearable applications,” inSENSORS, 2012 IEEE, 2012, pp. 1–4. [128] K. Myny, S. Smout, M. Rockelé, A. Bhoolokam, T. H. Ke, S. Steudel, B. Cobb,A. Gulati, F. G. Rodriguez, K. Obata, M. Marinkovic, D.-V. Pham, A. Hoppe, G. H.Gelinck, J. Genoe, W. Dehaene, and P. Heremans, “A thin-film microprocessor withinkjet print-programmable memory,” Scientific Reports, vol. 4, no. 1, p. 7398, Dec2014. [Online]. Available: https://doi.org/10.1038/srep07398 [129] H. Yasuda, T. Tachi, M. Lee, and J. Yang, “Origami-based tunable truss structures fornon-volatile mechanical memory operation,” Nature Communications, vol. 8, no. 1, p.962, Oct 2017. [Online]. Available: https://doi.org/10.1038/s41467-017-00670-w [130] S. Miyashita, L. Meeker, M. Go¨ldi, Y. Kawahara, and D. Rus, “Self-folding printableelastic electric devices: Resistor, capacitor, and inductor,” in 2014 IEEE InternationalConference on Robotics and Automation (ICRA), 2014, pp. 1446–1453. [131] S. Critcher and T. J. Freeborn, “Flexible pcb failures from dynamic activity and theirimpacts on bioimpedance measurements: A wearable case study,” IEEE Open Journalof Circuits and Systems, vol. 2, pp. 732–742, 2021. [132] S.-W. Hwang, H. Tao, D.-H. Kim, H. Cheng, J.-K. Song, E. Rill, M. A.Brenckle, B. Panilaitis, S. M. Won, Y.-S. Kim, Y. M. Song, K. J. Yu, A. Ameen,R. Li, Y. Su, M. Yang, D. L. Kaplan, M. R. Zakin, M. J. Slepian, Y. Huang,F. G. Omenetto, and J. A. Rogers, “A physically transient form of siliconelectronics,” Science, vol. 337, no. 6102, pp. 1640–1644, 2012. [Online]. Available:https://www.science.org/doi/abs/10.1126/science.1226325 [133] U.S. Food and Drug Administration, “Code of federal regulations, title 21, volume 6,section 582.1431,” 2024. [134] G.-Z. Yang, J. Bellingham, P. E. Dupont, P. Fischer, L. Floridi, R. Full, N. Jacobstein,V. Kumar, M. McNutt, R. Merrifield, B. J. Nelson, B. Scassellati, M. Taddeo,R. Taylor, M. Veloso, Z. L. Wang, and R. Wood, “The grand challenges of <i>sciencerobotics</i>,” Science Robotics, vol. 3, no. 14, p. eaar7650, 2018. [Online]. Available:https://www.science.org/doi/abs/10.1126/scirobotics.aar7650 [135] J. Gao, S. Tian, C. Yuan, Z. Ma, C. Gao, G. Yan, R. Li, Q. Tan, and L. Zhang, “Designand optimization of a novel double-layer helmholtz coil for wirelessly powering acapsule robot,” IEEE Transactions on Power Electronics, vol. 39, no. 1, pp. 1826–1839,2024. [136] S. R. Khan, S. K. Pavuluri, G. Cummins, and M. P. Y. Desmulliez, “Wireless powertransfer techniques for implantable medical devices: A review,” Sensors, vol. 20,no. 12, 2020. [137] S. R. Ruth, M. gu Kim, H. Oda, Z. Wang, Y. Khan, J. Chang, P. M.Fox, and Z. Bao, “Post-surgical wireless monitoring of arterial healthprogression,” iScience, vol. 24, no. 9, p. 103079, 2021. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S2589004221010476 [138] K. Obaideen, L. Albasha, U. Iqbal, and H. Mir, “Wireless power transfer: Applications,challenges, barriers, and the role of ai in achieving sustainable development goals - abibliometric analysis,” Energy Strategy Reviews, vol. 53, p. 101376, 2024. [Online].Available: https://www.sciencedirect.com/science/article/pii/S2211467X2400083X [139] K. Na, H. Jang, H. Ma, and F. Bien, “Tracking optimal efficiency of magnetic resonancewireless power transfer system for biomedical capsule endoscopy,” IEEETransactions on Microwave Theory and Techniques, vol. 63, no. 1, pp. 295–304, 2015. [140] J. Zhiwei, Y. Guozheng, Jiangpingping, W. Zhiwu, and L. Hua, “Efficiencyoptimization of wireless power transmission systems for active capsule endoscopes,”Physiological Measurement, vol. 32, no. 10, p. 1561, aug 2011. [Online]. Available:https://dx.doi.org/10.1088/0967-3334/32/10/005 [141] Y. Palagani, K. Mohanarangam, J. H. Shim, and J. R. Choi, “Wireless power transferanalysis of circular and spherical coils under misalignment conditions for biomedicalimplants,” Biosensors and Bioelectronics, vol. 141, p. 111283, 2019. [Online].Available: https://www.sciencedirect.com/science/article/pii/S0956566319303422 [142] Z. Jia, G. Yan, Y. Shi, and B. Zhu, “A wireless power transmission system for anactive capsule endoscope for colon inspection,” J. Med. Eng. Technol., vol. 36, no. 5,pp. 235–241, Jul. 2012. [143] B. Lenaerts and R. Puers, “An inductive power link for a wireless endoscope,”Biosensors and Bioelectronics, vol. 22, no. 7, pp. 1390–1395, 2007. [Online].Available: https://www.sciencedirect.com/science/article/pii/S0956566306002892 [144] M. R. Basar, M. Y. Ahmad, J. Cho, and F. Ibrahim, “An improved wearable resonantwireless power transfer system for biomedical capsule endoscope,” IEEE Transactionson Industrial Electronics, vol. 65, no. 10, pp. 7772–7781, 2018. [145] S. R. Khan, S. K. Pavuluri, G. Cummins, and M. P. Y. Desmulliez, “Miniaturized 3-dcross-type receiver for wirelessly powered capsule endoscopy,” IEEE Transactions onMicrowave Theory and Techniques, vol. 67, no. 5, pp. 1985–1993, 2019. [146] S. Aldhaher, P. C. K. Luk, and J. F. Whidborne, “Wireless power transfer using class einverter with saturable dc-feed inductor,” in 2013 IEEE Energy Conversion Congressand Exposition, 2013, pp. 1902–1909. [147] H. Liu, Q. Shao, and X. Fang, “Modeling and optimization of class-e amplifier atsubnominal condition in a wireless power transfer system for biomedical implants,”IEEE Transactions on Biomedical Circuits and Systems, vol. 11, no. 1, pp. 35–43,2017. [148] J. Wu, C. Zhao, Z. Lin, J. Du, Y. Hu, and X. He, “Wireless power and data transfer viaa common inductive link using frequency division multiplexing,” IEEE Transactionson Industrial Electronics, vol. 62, no. 12, pp. 7810–7820, 2015. [149] P. Wang, Y. Sun, X. Li, and Z. Ye, “An optimization method for simultaneouswireless power and data transfer systems,” Electronics, vol. 9, no. 12, 2020. [Online].Available: https://www.mdpi.com/2079-9292/9/12/2073 [150] H. Wang and J. Xu, “Research on the efficiency of multiphase wireless power transfersystem with phase-shift control and magnetic field superposition,” InternationalJournal of Electronics, vol. 108, no. 4, pp. 636–646, 2021. [Online]. Available:https://doi.org/10.1080/00207217.2020.1793410 [151] A. Abramson, E. Caffarel-Salvador, V. Soares, D. Minahan, R. Y. Tian, X. Lu, D. Dellal,Y. Gao, S. Kim, J. Wainer, J. Collins, S. Tamang, A. Hayward, T. Yoshitake,H.-C. Lee, J. Fujimoto, J. Fels, M. R. Frederiksen, N. Rahbek, Ulrikand Roxhed,R. Langer, and G. Traverso, “A luminal unfolding microneedle injector for oral deliveryof macromolecules,” Nature Medicine, vol. 25, no. 10, pp. 1512–1518, Oct2019. [152] U.S. Food and Drug Administration, “Code of federal regulations, title 21, volume 3,section 184.1033,” 1994. [153] ——, “Code of federal regulations, title 21, volume 3, section 184.1736,” 1983. [154] F. Fiorillo, Soft Magnetic Materials in Characterization and Measurement of MagneticMaterials. Elsevier, 2004. [155] H. B. Bohidar, “Hydrodynamic properties of gelatin in dilute solutions,” Int. J. Biol.Macromol., vol. 23, no. 1, pp. 1–6, Jul. 1998. [156] J. Kestin, M. Sokolov, and W. A. Wakeham, “Viscosity of liquid water in the range-8 °c to 150 °c,” Journal of Physical and Chemical Reference Data, vol. 7, no. 3, pp.941–948, 1978. [157] B. T. Smith, Solubility and Dissolution in Remington Education: Physical Pharmacy.London: Pharmaceutical Press, 2016. [158] W. J. Bae, J. B. Choi, K. S. Kim, S. J. Kim, H. J. Cho, U. S. Ha, S. H. Hong, J. Y. Lee,and S. W. Kim, “Ab168. evaluation of the biocompatibility of packing materials for acatheter,” Translational Andrology and Urology, vol. 4, no. Suppl 1, 2015. [159] Y. Yang, J. Wang, L. Wang, Q. Wu, L. Ling, Y. Yang, S. Ning, Y. Xie, Q. Cao, L. Li,J. Liu, Q. Ling, and J. Zang, “Magnetic soft robotic bladder for assisted urination,”Science Advances, vol. 8, no. 34, 2022. [160] H. Yuk, C. E. Varela, C. S. Nabzdyk, X. Mao, R. F. Padera, E. T. Roche, and X. Zhao,“Dry double-sided tape for adhesion of wet tissues and devices,” Nature, vol. 575, no.7781, pp. 169–174, Nov 2019. [161] H. Tang and M. Mayersohn, “Porcine prediction of pharmacokinetic parameters inpeople: A pig in a poke?” Drug Metabolism and Disposition, vol. 46, no. 11, pp.1712–1724, 2018. [162] G. Bandini, A. Buffi, M. Marracci, B. Tellini, T. Rizzo, M. Macucci, S. Strangio,and G. Iannaccone, “Electromagnetic design of an inductive wireless power transfersystem for endoscopic capsule,” in 2023 IEEE International Instrumentation andMeasurement Technology Conference (I2MTC), 2023, pp. 1–6."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/M508135/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/36627/1/KaanEsendag_ThesisFinal.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Capsule robots provide an alternative route of entry to the gastrointestinal tract with minimal discomfort to patients. There are many examples of therapeutic capsules, but a gap exists in their capability in carrying out complex surgical functions such as manipulation in a suitable capsule size. There are two major factors for that limit the size of capsules; small scale actuators and on-board computation and communication required to control them. Controlling soft actuation wirelessly with an on-board pneumatic source of pressure could help with miniaturisation of efficient small scale actuators due to their scalability. An untethered robotic capsule that can provide volumetric expansion using a chemical reaction without on-board electronic components was designed along with a theoretical model for predicting the inflation behaviour. The expansion is based on the reaction between chemicals that are safe for ingestion, operated with thermal input provided by alternating magnetic fields from outside the body. Additionally, a new amplifier design that can deliver power to simple receiver circuits in parallel was presented. This allows the control of a wireless capsule that can use the electrical power for applications such as heating a target location, powering small motors bidirectionally and turn on LEDs without the use of a microcontroller. The design was tested for up to 6 addressable components, and an analysis on the limitations of this approach has been carried out. An example design of a capsule robot capable of anchoring itself to the intestinal tissues, use its manipulator arm to target a specific location and heat the location to patch wounds, or destroy pathogens or cancer cells was presented. Together, the wireless soft actuator and the wireless powering method should benefit further miniaturisation of therapeutic capsule robots capable of more complex in-vivo surgical functionality."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Wireless Surgical Capsule Robots for the Gastrointestinal Tract: Towards small scale therapeutic functions without on-board computation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Damian, Dana"],"dc:contributor.sponsor":["EPSRC DTP Early Career Researcher Scholarship"],"dc:creator":["Esendag, Kaan"],"dc:date":["2025-03"],"dc:date.issued":["2025-03"],"dc:description.abstract":["Capsule robots provide an alternative route of entry to the gastrointestinal tract with minimal discomfort to patients. There are many examples of therapeutic capsules, but a gap exists in their capability in carrying out complex surgical functions such as manipulation in a suitable capsule size. There are two major factors for that limit the size of capsules; small scale actuators and on-board computation and communication required to control them. Controlling soft actuation wirelessly with an on-board pneumatic source of pressure could help with miniaturisation of efficient small scale actuators due to their scalability. An untethered robotic capsule that can provide volumetric expansion using a chemical reaction without on-board electronic components was designed along with a theoretical model for predicting the inflation behaviour. The expansion is based on the reaction between chemicals that are safe for ingestion, operated with thermal input provided by alternating magnetic fields from outside the body. Additionally, a new amplifier design that can deliver power to simple receiver circuits in parallel was presented. This allows the control of a wireless capsule that can use the electrical power for applications such as heating a target location, powering small motors bidirectionally and turn on LEDs without the use of a microcontroller. The design was tested for up to 6 addressable components, and an analysis on the limitations of this approach has been carried out. An example design of a capsule robot capable of anchoring itself to the intestinal tissues, use its manipulator arm to target a specific location and heat the location to patch wounds, or destroy pathogens or cancer cells was presented. Together, the wireless soft actuator and the wireless powering method should benefit further miniaturisation of therapeutic capsule robots capable of more complex in-vivo surgical functionality."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/M508135/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/36627/1/KaanEsendag_ThesisFinal.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Automatic Control and Systems Engineering (Sheffield)","Electronic and Electrical Engineering (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/36627/"],"dc:relation.references":["[1] M. Simi, G. Gerboni, A. Menciassi, and P. Valdastri, “Magnetic torsion springmechanism for a wireless biopsy capsule,” Journal of Medical Devices, vol. 7, no. 4,p. 041009, 09 2013. [Online]. Available: https://doi.org/10.1115/1.4025185 [2] D. Ye, J. Xue, S. Yuan, F. Zhang, S. Song, J. Wang, and M. Q.-H. Meng, “Designand control of a magnetically-actuated capsule robot with biopsy function,” IEEETransactions on Biomedical Engineering, vol. 69, no. 9, pp. 2905–2915, 2022. [3] Z. Nagy, R. Oung, J. J. Abbott, and B. J. Nelson, “Experimental investigation of magneticself-assembly for swallowable modular robots,” in 2008 IEEE/RSJ InternationalConference on Intelligent Robots and Systems, 2008, pp. 1915–1920. [4] L. Yan, T. Wang, D. Liu, J. Peng, Z. Jiao, and C.-Y. Chen, “Capsule robot forobesity treatment with wireless powering and communication,” IEEE Transactions onIndustrial Electronics, vol. 62, no. 2, pp. 1125–1133, 2015. [5] Y. Tang, M. Li, T. Wang, X. Dong, W. Hu, and M. Sitti, “Wireless miniature magneticphase-change soft actuators,” Advanced Materials, 2022. [6] M. Boyvat, D. M. Vogt, and R. J. Wood, “Ultrastrong and high-strokewireless soft actuators through liquid-gas phase change,” Advanced MaterialsTechnologies, vol. 4, no. 2, p. 1800381, 2019. [Online]. Available: https://onlinelibrary.wiley.com/doi/abs/10.1002/admt.201800381 [7] S. Wu, Y. Hong, Y. Zhao, J. Yin, and Y. Zhu, “Caterpillar-inspired softcrawling robot with distributed programmable thermal actuation,” ScienceAdvances, vol. 9, no. 12, p. eadf8014, 2023. [Online]. Available: https://www.science.org/doi/abs/10.1126/sciadv.adf8014 [8] M. E. M. K. Abdelaziz, J. Zhao, B. G. Rosa, H.-T. Lee, D. Simon, K. Vyas,B. Li, H. Koguna, Y. Li, A. A. Demircali, H. Uvet, G. Gencoglan, A. Akcay,M. Elriedy, J. Kinross, R. Dasgupta, Z. Takats, E. Yeatman, G.-Z. Yang, andB. Temelkuran, “Fiberbots: Robotic fibers for high-precision minimally invasivesurgery,” Science Advances, vol. 10, no. 3, p. eadj1984, 2024. [Online]. Available:https://www.science.org/doi/abs/10.1126/sciadv.adj1984 [9] M. S. M. Ali and K. Takahata, “Wireless microfluidic control with integratedshape-memory-alloy actuators operated by field frequency modulation,” Journal ofMicromechanics and Microengineering, vol. 21, no. 7, p. 075005, jun 2011. [Online].Available: https://dx.doi.org/10.1088/0960-1317/21/7/075005 [10] W. Chen, J. Sui, and C. Wang, “Magnetically actuated capsule robots: A review,”IEEE Access, vol. 10, pp. 88 398–88 420, 2022. [11] R. L. Siegel, K. D. Miller, N. S. Wagle, and A. Jemal, “Cancer statistics, 2023,” CA: ACancer Journal for Clinicians, vol. 73, no. 1, pp. 17–48, 2023. [Online]. Available:https://acsjournals.onlinelibrary.wiley.com/doi/abs/10.3322/caac.21763 [12] M. F. Hale, R. Sidhu, and M. E. McAlindon, “Capsule endoscopy: current practice andfuture directions,” World journal of gastroenterology, vol. 20, no. 24, pp. 7752–7759,Jun 2014. [13] S. N. Adler and Y. C. Metzger, “PillCam COLON capsule endoscopy: recent advancesand new insights,” Therapeutic Advances in Gastroenterology, vol. 4, no. 4, pp. 265–268, Jul. 2011. [14] N. K. Mandsberg, J. F. Christfort, K. Kamguyan, A. Boisen, and S. K. Srivastava,“Orally ingestible medical devices for gut engineering,” Advanced Drug DeliveryReviews, vol. 165-166, pp. 142–154, 2020. [15] H.-L. Ching, M. F. Hale, and M. E. McAlindon, “Current and future role ofmagnetically assisted gastric capsule endoscopy in the upper gastrointestinal tract,”Therapeutic Advances in Gastroenterology, vol. 9, no. 3, pp. 313–321, 2016, pMID:27134661. [Online]. Available: https://doi.org/10.1177/1756283X16633052 [16] S. Yim and M. Sitti, “Shape-programmable soft capsule robots for semi-implantabledrug delivery,” IEEE Transactions on Robotics, vol. 28, no. 5, pp. 1198–1202, 2012. [17] W. Yu, R. Rahimi, M. Ochoa, R. Pinal, and B. Ziaie, “A smart capsule with gi-tractlocation-specific payload release,” IEEE Transactions on Biomedical Engineering,vol. 62, no. 9, pp. 2289–2295, 2015. [18] O. Erin, M. Boyvat, J. Lazovic, M. E. Tiryaki, and M. Sitti, “Wireless mri-poweredreversible orientation-locking capsule robot,” Advanced Science, vol. 8, no. 13, p.2100463, 2021. [Online]. Available: https://onlinelibrary.wiley.com/doi/abs/10.1002/advs.202100463 [19] V. H. Le, H. L. Rodriguez, C. Lee, G. Go, J. Zhen, V. D. Nguyen, H. Choi, S. Y.Ko, J.-O. Park, and S. Park, “A soft-magnet-based drug-delivery module for activelocomotive intestinal capsule endoscopy using an electromagnetic actuation system,”Sensors and Actuators A: Physical, vol. 243, pp. 81–89, 2016. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S0924424716301194 [20] M. Beccani, G. Aiello, N. Gkotsis, H. Tunc, A. Taddese, E. Susilo,P. Völgyesi, Ákos Lédeczi, E. D. Momi, and P. Valdastri, “Componentbased design of a drug delivery capsule robot,” Sensors and ActuatorsA: Physical, vol. 245, pp. 180–188, 2016. [Online]. Available: https://www.sciencedirect.com/science/article/pii/S0924424716301807 [21] M. Rehan, I. Al-Bahadly, D. G. Thomas, W. Young, L. K. Cheng, andE. Avci, “Smart capsules for sensing and sampling the gut: status, challengesand prospects,” Gut, vol. 73, no. 1, pp. 186–202, 2024. [Online]. Available:https://gut.bmj.com/content/73/1/186 [22] Y. L. Kong, X. Zou, C. A. McCandler, A. R. Kirtane, S. Ning, J. Zhou, A. Abid,M. Jafari, J. Rogner, D. Minahan, J. E. Collins, S. McDonnell, C. Cleveland, T. Bensel,S. Tamang, G. Arrick, A. Gimbel, T. Hua, U. Ghosh, V. Soares, N. Wang, A. Wahane,A. Hayward, S. Zhang, B. R. Smith, R. Langer, and G. Traverso, “3d-printed gastricresident electronics,” Advanced Materials Technologies, vol. 4, no. 3, p. 1800490,2019. [23] V. H. Le, V. D. Nguyen, C. Lee, G. Go, J.-O. Park, and S. Park,“Miniaturized biopsy module using gripper tool for active locomotive capsuleendoscope,” Mechatronics, vol. 44, pp. 52–59, 2017. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S0957415817300582 [24] D. Ye, F. Zhang, S. Yuan, S. Song, and M. Q.-H. Meng, “Magnetically driven wirelesscapsule robot with targeting biopsy function,” in 2019 IEEE International Conferenceon Robotics and Biomimetics (ROBIO), 2019, pp. 1222–1227. [25] M. Rehan, I. Al-Bahadly, D. G. Thomas, and E. Avci, “Development of a roboticcapsule for in vivo sampling of gut microbiota,” IEEE Robotics and AutomationLetters, vol. 7, no. 4, pp. 9517–9524, 2022. [26] H. Rezaei Nejad, B. C. M. Oliveira, A. Sadeqi, A. Dehkharghani, I. Kondova,J. A. M. Langermans, J. S. Guasto, S. Tzipori, G. Widmer, and S. R. Sonkusale,“Ingestible osmotic pill for in vivo sampling of gut microbiomes,” AdvancedIntelligent Systems, vol. 1, no. 5, p. 1900053, 2019. [Online]. Available:https://onlinelibrary.wiley.com/doi/abs/10.1002/aisy.201900053 [27] F. Munoz, G. Alici, and W. Li, “A review of drug delivery systems for capsuleendoscopy,” Advanced Drug Delivery Reviews, vol. 71, pp. 77–85, 2014. [28] S. Song, S. Yuan, F. Zhang, J. Su, D. Ye, J. Wang, and M. Q.-H. Meng, “Integrateddesign and decoupled control of anchoring and drug release for wireless capsulerobots,” IEEE/ASME Transactions on Mechatronics, vol. 27, no. 5, pp. 2897–2907,2022. [29] J. Gao and G. Yan, “Design and implementation of a clamper-based and motor-drivencapsule robot powered by wireless power transmission,” IEEE Access, vol. 7, pp.138 151–138 161, 2019. [30] W. Chen, Q. Ke, S. He, W. Luo, X. C. Ji, and G. Yan, “Experimental research onanchoring force in intestine for the motion of capsule robot,” Journal of MedicalEngineering and Technology, vol. 37, no. 5, pp. 334–341, 2013. [31] B. H. K. Leung, C. C. Y. Poon, R. Zhang, Y. Zheng, C. K. W. Chan, P. W. Y. Chiu,J. Y. W. Lau, and J. J. Y. Sung, “A therapeutic wireless capsule for treatment ofgastrointestinal haemorrhage by balloon tamponade effect,” IEEE Transactions onBiomedical Engineering, vol. 64, no. 5, pp. 1106–1114, 2017. [32] J. A. Vale, P. D. Miller, and R. S. Kirby, “Balloon dilatation of the prostate–shouldit have a place in the urologist’s armamentarium?” J R Soc Med, vol. 86, no. 2, pp.83–86, Feb. 1993. [33] K. Sunada, H. Yamamoto, H. Kita, T. Yano, H. Sato, Y. Hayashi, T. Miyata, Y. Sekine,A. Kuno, M. Iwamoto, H. Ohnishi, K. Ido, and K. Sugano, “Clinical outcomes ofenteroscopy using the double-balloon method for strictures of the small intestine,”World J Gastroenterol, vol. 11, no. 7, pp. 1087–1089, Feb. 2005. [34] Pasricha, T. Smith, B. F. ; Mitchell, V. R. ; Fang, B. Brooks, E. R. ; Gerding, J. S.; Washington, M. K. Valdastri, P. Obstein, and K. L., “Controlled colonic insufflationby a remotely triggered capsule for improved mucosal visualization,” Endoscopy,vol. 46, no. 07, pp. 614–618, Jun. 2014. [35] P. Valdastri, M. Simi, and R. J. Webster, 3rd, “Advanced technologies for gastrointestinalendoscopy,” The Annual Reviews of Biomedical Engineering, vol. 14, pp. 397–429,May 2012. [36] M. Adami and A. Seibel, “On-board pneumatic pressure generation methods for softrobotics applications,” Actuators, vol. 8, no. 1, 2019. [37] A. L. Evenchik, A. Q. Kane, E. Oh, and R. L. Truby, “Electrically controllablematerials for soft, bioinspired machines,” Annual Review of Materials Research,vol. 53, no. Volume 53, 2023, pp. 225–251, 2023. [Online]. Available: https://www.annualreviews.org/content/journals/10.1146/annurev-matsci-080921-102916 [38] J. Jung, S. Shin, M. Li, and Y. T. Kim, “Telemetry transmission to support bidirectionalcommunication for capsule endoscope using human body communication,” IEEEMicrowave and Wireless Components Letters, vol. 31, no. 7, pp. 905–908, 2021. [39] R. Fontana, F. Mulana, C. Cavallotti, G. Tortora, M. Vigliar, M. Vatteroni, andA. Menciassi, “An innovative wireless endoscopic capsule with spherical shape,” IEEETransactions on Biomedical Circuits and Systems, vol. 11, no. 1, pp. 143–152, 2017. [40] M. J. Christoe, J. Yuan, A. Michael, and K. Kalantar-Zadeh, “Bluetooth signal attenuationanalysis in human body tissue analogues,” IEEE Access, vol. 9, pp. 85 144–85 150,2021. [41] J. H. Palep, “Robotic assisted minimally invasive surgery,” Journal of Minimal AccessSurgery, vol. 5, no. 1, pp. 1–7, Jan. 2009. [42] J. Huang, Z. Zhang, and S. Wang, “Efficacy of the da vinci surgicalsystem in colorectal surgery comparing with traditional laparoscopic surgery oropen surgery: A meta-analysis,” International Journal of Advanced RoboticSystems, vol. 13, no. 5, p. 1729881416664849, 2016. [Online]. Available:https://doi.org/10.1177/1729881416664849 [43] T. Haidegger, S. Speidel, D. Stoyanov, and R. M. Satava, “Robot-assisted minimallyinvasive surgery—surgical robotics in the data age,” Proceedings of the IEEE, vol.110, no. 7, pp. 835–846, 2022. [44] A. R. Lanfranco, A. E. Castellanos, J. P. Desai, and W. C. Meyers, “Robotic surgery:a current perspective,” Annals of Surgery, vol. 239, no. 1, pp. 14–21, Jan. 2004. [45] D. Jain, A. Goyal, and S. Zavala, “Predicting colonoscopy time: A quality improvementinitiative,” Clinical Endoscopy, vol. 49, no. 6, pp. 555–559, 2016. [46] H. Kang and M. H. Thoufeeq, “Size of colorectal polyps determines time takento remove them endoscopically,” Endoscopy International Open, vol. 6, no. 5, pp.E610–E615, 2018. [47] U. Akyuz and F. Akyuz, “Diagnostic and therapeutic capability of Double-Balloonenteroscopy in clinical practice,” Clin Endosc, vol. 49, no. 2, pp. 157–160, Mar. 2016. [48] S. R. Lieber, B. J. Heller, C. F. Martin, C.W. Howard, and S. Crockett, “Complicationsof anesthesia services in gastrointestinal endoscopic procedures,” ClinicalGastroenterology and Hepatology, vol. 18, no. 9, pp. 2118–2127.e4, 2020. [Online].Available: https://www.sciencedirect.com/science/article/pii/S1542356519311103 [49] R. M. Bonnor and K. A. Ludwig, “Laparoscopic colectomy for colon cancer: comparableto conventional oncologic surgery?” Clin. Colon Rectal Surg., vol. 18, no. 3, pp.174–181, aug 2005. [50] K. Wang, J. Ma, F. Wang, Z. Wang, G. Yan, and Y. Zhou, “Full-driving soft roboticcolonoscope in compliant colon tissue,” J. Med. Eng. Technol., vol. 41, no. 8, pp.662–669, Nov. 2017. [51] C. J. Fyock and P. V. Draganov, “Colonoscopic polypectomy and associated techniques,”World journal of gastroenterology, vol. 16, no. 29, pp. 3630–3637, 2010. [52] L. Liu, S. Towfighian, and A. Hila, “A review of locomotion systems for capsuleendoscopy,” IEEE Reviews in Biomedical Engineering, vol. 8, pp. 138–151, 2015. [53] H. F. Helander and L. Fändriks, “Surface area of the digestive tract - revisited,”Scandinavian Journal of Gastroenterology, vol. 49, no. 6, pp. 681–689, 2014. [54] G. Kiran, I. Yilmaz, S. Aydin, F. Sanlikan, and E. Ozkaya, “The shortest distancebetween the skin and the peritoneal cavity is obtained with fascial elevation: a preliminaryprospective laparoscopic entry study,” Facts Views Vis Obgyn, vol. 14, no. 2, pp.171–175, Jun. 2022. [55] A. E. Deatsch and B. A. Evans, “Heating efficiency in magnetic nanoparticle hyperthermia,”Journal of Magnetism and Magnetic Materials, vol. 354, pp. 163–172,2014. [56] A. Bhardwaj, K. Parekh, and N. Jain, “In vitro hyperthermic effect of magnetic fluidon cervical and breast cancer cells,” Scientific Reports, vol. 10, no. 1, p. 15249, Sep2020. [57] P. R. Slawinski, K. L. Obstein, and P. Valdastri, “Capsule endoscopy of the future:What’s on the horizon?” World J Gastroenterol, vol. 21, no. 37, pp. 10 528–10 541,Oct. 2015. [58] Q. Cao, R. Deng, Y. Pan, R. Liu, Y. Chen, G. Gong, J. Zou, H. Yang, and D. Han,“Robotic wireless capsule endoscopy: recent advances and upcoming technologies,”Nature Communications, vol. 15, no. 1, p. 4597, May 2024. [Online]. Available:https://doi.org/10.1038/s41467-024-49019-0 [59] A. Z. Taddese, P. R. Slawinski, K. L. Obstein, and P. Valdastri, “Closed loop controlof a tethered magnetic capsule endoscope,” Robot Sci Syst, vol. 2016, Jun. 2016. [60] S. Miyashita, S. Guitron, K. Yoshida, S. Li, D. D. Damian, and D. Rus, “Ingestible,controllable, and degradable origami robot for patching stomach wounds,” in 2016IEEE International Conference on Robotics and Automation (ICRA), 2016, pp. 909–916. [61] A. du Plessis d’Argentré, S. Perry, Y. Iwata, H. Iwasaki, E. Iwase, A. Fabozzo, I. Will,D. Rus, D. D. Damian, and S. Miyashita, “Programmable medicine: Autonomous,ingestible, deployable hydrogel patch and plug for stomach ulcer therapy,” in 2018IEEE International Conference on Robotics and Automation (ICRA), 2018, pp. 1511–1518. [62] Y. Shi, G. Yan, W. Chen, and B. Zhu, “Micro-intestinal robot withwireless power transmission: design, analysis and experiment,” Computersin Biology and Medicine, vol. 66, pp. 343–351, 2015. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S0010482515002036 [63] K. Wang, G. Yan, G. Ma, and D. Ye, “An earthworm-like robotic endoscopesystem for human intestine: Design, analysis, and experiment,” Annals ofBiomedical Engineering, vol. 37, no. 1, pp. 210–221, Jan 2009. [Online]. Available:https://doi.org/10.1007/s10439-008-9597-6 [64] R. A. Ganz, J. Viveiros, A. Ahmad, A. Ahmadi, A. Khalil, M. J. Tolkoff, N. S.Nishioka, and M. R. Hamblin, “Helicobacter pylori in patients can be killed by visiblelight,” Lasers in Surgery and Medicine, vol. 36, no. 4, pp. 260–265, 2005. [Online].Available: https://onlinelibrary.wiley.com/doi/abs/10.1002/lsm.20161 [65] G. Tortora, B. Orsini, P. Pecile, A. Menciassi, F. Fusi, and G. Romano, “An ingestiblecapsule for the photodynamic therapy of helicobacter pylori infection,” IEEE/ASMETransactions on Mechatronics, vol. 21, no. 4, pp. 1935–1942, 2016. [66] Q. Tang, G. Jin, G. Wang, T. Liu, X. Liu, B. Wang, and H. Cao, “Currentsampling methods for gut microbiota: A call for more precise devices,”Frontiers in Cellular and Infection Microbiology, vol. 10, 2020. [Online].Available: https://www.frontiersin.org/journals/cellular-and-infection-microbiology/articles/10.3389/fcimb.2020.00151 [67] J. Wang, M. Leach, E. G. Lim, Z. Wang, R. Pei, and Y. Huang, “An implantable andconformal antenna for wireless capsule endoscopy,” IEEE Antennas and WirelessPropagation Letters, vol. 17, no. 7, pp. 1153–1157, 2018. [68] P. R. Slawinski, K. L. Obstein, and P. Valdastri, “Emerging issues and future developmentsin capsule endoscopy,” Techniques in Gastrointestinal Endoscopy, vol. 17,no. 1, pp. 40–46, 2015. [69] B. Boyd, K. Esendag, S. Miyashita, and D. D. Damian, “Development of a nearfieldwireless power transfer system for controlling electronic motors within capsuleendoscopes,” in Hamlyn Symposium on Medical Robotics 2024, vol. 16, June 2024,pp. 95–96. [70] Z. Li, M. C. Hoang, C.-S. Kim, E. Choi, D. Bang, J.-O. Park, and B. Kang, “Modularcapsules with assembly and separation mechanism: Proof of concept,” Actuators,vol. 10, no. 7, 2021. [Online]. Available: https://www.mdpi.com/2076-0825/10/7/159 [71] F. Peker and O. Ferhano˘glu, “Multi-capsule endoscopy: An initial study on modelingand phantom experimentation of a magnetic capsule train,” Journal of Medical andBiological Engineering, vol. 41, no. 3, pp. 315–321, Jun 2021. [Online]. Available:https://doi.org/10.1007/s40846-021-00610-6 [72] J. Guo, P. Liu, S. Guo, L. Wang, and G. Sun, “Development of a novel wireless spiralcapsule robot with modular structure,” in 2017 IEEE International Conference onMechatronics and Automation (ICMA), 2017, pp. 439–444. [73] X. Ma, D. E. Vogtmann, and S. Bergbreiter, “Dynamics and scaling ofmagnetically folding multi-material structures,” 2016 IEEE International Conferenceon Robotics and Automation (ICRA), pp. 1899–1906, 2016. [Online]. Available:https://api.semanticscholar.org/CorpusID:17929579 [74] H. Suzuki and R. J. Wood, “Origami-inspired miniature manipulator for teleoperatedmicrosurgery,” Nature Machine Intelligence, vol. 2, no. 8, pp. 437–446, 2020. [75] J. Liu, X. Chen, Q. Lahondes, K. Esendag, D. Damian, and S. Miyashita, “Origamirobot self-folding by magnetic induction,” in 2022 IEEE/RSJ International Conferenceon Intelligent Robots and Systems (IROS), 2022, pp. 2519–2525. [76] J. Han, D. Rus, and S. Miyashita, “Roblets: Robotic tablets that self-assemble andself-fold into a robot,” in 2023 IEEE/RSJ International Conference on IntelligentRobots and Systems (IROS), 2023, pp. 4709–4714. [77] M. P. Kummer, J. J. Abbott, B. E. Kratochvil, R. Borer, A. Sengul, and B. J. Nelson,“Octomag: An electromagnetic system for 5-dof wireless micromanipulation,” IEEETransactions on Robotics, vol. 26, no. 6, pp. 1006–1017, 2010. [78] K. Esendag, M. E. McAlindon, D. Rus, S. Miyashita, and D. D. Damian, “Developmentof an untethered inflatable capsule robot for stricture dilation - a preliminary study,” inHamlyn Symposium on Medical Robotics 2023, vol. 15, June 2023, pp. 101–102. [79] O. Onaizah and E. Diller, “Tetherless mobile micro-surgical scissors using magneticactuation,” in 2019 International Conference on Robotics and Automation (ICRA),2019, pp. 894–899. [80] A. Lim, A. Schonewille, C. Forbrigger, T. Looi, J. Drake, and E. Diller, “Designand comparison of magnetically-actuated dexterous forceps instruments for neuroendoscopy,”IEEE Transactions on Biomedical Engineering, vol. 68, no. 3, pp. 846–856,2021. [81] S. Guitron, A. Guha, S. Li, and D. Rus, “Autonomous locomotion of a miniature,untethered origami robot using hall effect sensor-based magnetic localization,” in2017 IEEE International Conference on Robotics and Automation (ICRA), 2017, pp.4807–4813. [82] J. Liu, H. Sugiyama, T. Nakayama, and S. Miyashita, “Magnetic sensor based topographiclocalization for automatic dislocation of ingested button battery,” in 2020 IEEEInternational Conference on Robotics and Automation (ICRA), 2020, pp. 5488–5494. [83] D. Wang, B. Zhao, X. Li, L. Dong, M. Zhang, J. Zou, and G. Gu, “Dexterouselectrical-driven soft robots with reconfigurable chiral-lattice foot design,” NatureCommunications, vol. 14, no. 1, p. 5067, Aug 2023. [Online]. Available:https://doi.org/10.1038/s41467-023-40626-x [84] A. Wiranata, M. Kanno, N. Chiya, H. Okabe, T. Horii, T. Fujie, N. Hosoya, andS. Maeda, “High-frequency oscillations of low-voltage dielectric elastomer actuators,”Applied Physics Express, vol. 15, 12 2021. [85] S. Rahmanian, A. Alibakhshi, H. Mouharrar, J. M. Benitez, and F. J. Montáns, “Lowvoltagedielectric elastomer actuators by electro-mechanical resonance syntonization,”International Journal of Mechanical Sciences, vol. 263, p. 108758, 2024. [Online].Available: https://www.sciencedirect.com/science/article/pii/S0020740323006604 [86] S. Wu, G. L. Baker, J. Yin, and Y. Zhu, “Fast thermal actuators for soft robotics,” SoftRobotics, vol. 9, no. 6, pp. 1031–1039, 2022, pMID: 34874763. [Online]. Available:https://doi.org/10.1089/soro.2021.0080 [87] Y. Wu, J. K. Yim, J. Liang, Z. Shao, M. Qi, J. Zhong, Z. Luo, X. Yan, M. Zhang,X. Wang, R. S. Fearing, R. J. Full, and L. Lin, “Insect-scale fast moving andultrarobust soft robot,” Science Robotics, vol. 4, no. 32, p. eaax1594, 2019. [Online].Available: https://www.science.org/doi/abs/10.1126/scirobotics.aax1594 [88] S. M. Felton, K. P. Becker, D. M. Aukes, and R. J. Wood, “Self-folding withshape memory composites at the millimeter scale,” Journal of Micromechanicsand Microengineering, vol. 25, no. 8, p. 085004, jul 2015. [Online]. Available:https://dx.doi.org/10.1088/0960-1317/25/8/085004 [89] N. Sabahi, W. Chen, C.-H. Wang, J. J. Kruzic, and X. Li, “A review onadditive manufacturing of shape-memory materials for biomedical applications,”JOM, vol. 72, no. 3, pp. 1229–1253, Mar 2020. [Online]. Available:https://doi.org/10.1007/s11837-020-04013-x [90] M.-S. Kim, J.-K. Heo, H. Rodrigue, H.-T. Lee, S. Pané, M.-W. Han, and S.-H.Ahn, “Shape memory alloy (sma) actuators: The role of material, form, and scalingeffects,” Advanced Materials, vol. 35, no. 33, p. 2208517, 2023. [Online]. Available:https://onlinelibrary.wiley.com/doi/abs/10.1002/adma.202208517 [91] W. Huang, Z. Ding, C. Wang, J. Wei, Y. Zhao, and H. Purnawali, “Shape memorymaterials,” Materials Today, vol. 13, no. 7, pp. 54–61, 2010. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S1369702110701280 [92] K. Wang, H. Si, Q. Wan, Z. Wang, A. Qin, and B. Z. Tang, “Luminescenttwo-way reversible shape memory polymers prepared by hydroxyl–yne clickpolymerization,” J. Mater. Chem. C, vol. 8, pp. 16 121–16 128, 2020. [Online].Available: http://dx.doi.org/10.1039/D0TC03888A [93] R. Regmi, S. R. Bhattarai, C. Sudakar, A. S. Wani, R. Cunningham, P. P. Vaishnava,R. Naik, D. Oupicky, and G. Lawes, “Hyperthermia controlled rapid drug releasefrom thermosensitive magnetic microgels,” J. Mater. Chem., vol. 20, pp. 6158–6163,2010. [Online]. Available: http://dx.doi.org/10.1039/C0JM00844C [94] F. G. Downs, D. J. Lunn, M. J. Booth, J. B. Sauer, W. J. Ramsay, R. G. Klemperer,C. J. Hawker, and H. Bayley, “Multi-responsive hydrogel structures from patterneddroplet networks,” Nature Chemistry, vol. 12, no. 4, pp. 363–371, Apr 2020. [Online].Available: https://doi.org/10.1038/s41557-020-0444-1 [95] Y. S. Kim, M. Liu, Y. Ishida, Y. Ebina, M. Osada, T. Sasaki, T. Hikima, M. Takata,and T. Aida, “Thermoresponsive actuation enabled by permittivity switching inan electrostatically anisotropic hydrogel,” Nature Materials, vol. 14, no. 10, pp.1002–1007, Oct 2015. [Online]. Available: https://doi.org/10.1038/nmat4363 [96] M. Santhamoorthy, T. T. Vy Phan, V. Ramkumar, C. J. Raorane, K. Thirupathi,and S.-C. Kim, “Thermo-sensitive poly (n-isopropylacrylamide-co-polyacrylamide)hydrogel for ph-responsive therapeutic delivery,” Polymers, vol. 14, no. 19, 2022.[Online]. Available: https://www.mdpi.com/2073-4360/14/19/4128 [97] S. M. Mirvakili and R. Langer, “Wireless on-demand drug delivery,” Nature Electronics,vol. 4, no. 7, pp. 464–477, 2021. [98] C. Löwenberg, M. Balk, C. Wischke, M. Behl, and A. Lendlein, “Shape-memoryhydrogels: Evolution of structural principles to enable shape switching of hydrophilicpolymer networks,” Accounts of Chemical Research, vol. 50, no. 4, pp. 723–732,2017. [Online]. Available: https://doi.org/10.1021/acs.accounts.6b00584 [99] A. Razmjou, M. R. Barati, G. P. Simon, K. Suzuki, and H. Wang, “Fast deswelling ofnanocomposite polymer hydrogels via magnetic field-induced heating for emerging fodesalination,” Environmental Science & Technology, vol. 47, no. 12, pp. 6297–6305,2013, pMID: 23663180. [Online]. Available: https://doi.org/10.1021/es4005152 [100] Y. Liu, B. Shaw, M. D. Dickey, and J. Genzer, “Sequential self-folding of polymersheets,” Science Advances, vol. 3, no. 3, p. e1602417, 2017. [Online]. Available:https://www.science.org/doi/abs/10.1126/sciadv.1602417 [101] M. Boyvat and M. Sitti, “Remote modular electronics for wireless magneticdevices,” Advanced Science, vol. 8, no. 17, p. 2101198, 2021. [Online]. Available:https://onlinelibrary.wiley.com/doi/abs/10.1002/advs.202101198 [102] J. Baltrusaitis and V. H. Grassian, “Carbonic acid formation from reaction of carbondioxide and water coordinated to al(oh)3: A quantum chemical study,” The Journal ofPhysical Chemistry A, vol. 114, no. 6, pp. 2350–2356, 2010. [103] V. Vallem, E. Roosa, T. Ledinh, S. Rashid Nadimi, A. Kiani, and M. D. Dickey,“Soft electrochemical bubble actuator with liquid metal electrode using an embodiedhydrogel pneumatic source,” Soft Matter, vol. 18, pp. 9291–9298, 2022. [Online].Available: http://dx.doi.org/10.1039/D2SM00874B [104] S. M. Mirvakili, D. Sim, I. W. Hunter, and R. Langer, “Actuation of untetheredpneumatic artificial muscles and soft robots using magnetically induced liquid-to-gasphase transitions,” Science Robotics, vol. 5, no. 41, 2020. [105] S. Hirai, T. Nagatomo, T. Hiraki, H. Ishizuka, Y. Kawahara, and N. Miki, “Microelastic pouch motors: Elastically deformable and miniaturized soft actuators usingliquid-to-gas phase change,” IEEE Robotics and Automation Letters, vol. 6, no. 3, pp.5373–5380, 2021. [106] S. T. Brittain, O. J. A. Schueller, H. Wu, S. Whitesides, and G. M. Whitesides,“Microorigami: Fabrication of small, three-dimensional, metallic structures,” TheJournal of Physical Chemistry B, vol. 105, no. 2, pp. 347–350, 2001. [Online].Available: https://doi.org/10.1021/jp002556e [107] T. Tachi, “Origamizer,” 2010, accessed on October 31, 2024. [Online]. Available:www.tsg.ne.jp/TT/software/ [108] ——, “Origamizing polyhedral surfaces,” IEEE transactions on visualization andcomputer graphics, vol. 16, pp. 298–311, 03 2010. [109] E. D. Demaine, M. L. Demaine, D. Koschitz, and T. Tachi, “Curved crease folding- a review on art, design and mathematics,” in Semantic Scholar, 2011. [Online].Available: https://api.semanticscholar.org/CorpusID:15416501 [110] N. Benbernou, E. D. Demaine, M. L. Demaine, and A. Ovadya, “A universalcrease pattern for folding orthogonal shapes,” 2009. [Online]. Available:https://arxiv.org/abs/0909.5388 [111] T. Tachi, “3d origami design based on tucking molecule,” in Semantic Scholar, 2008.[Online]. Available: https://api.semanticscholar.org/CorpusID:15986677 [112] A. Yellowhorse and L. L. Howell, “Creating rigid foldability to enable mobility oforigami-inspired mechanisms,” Journal of Mechanisms and Robotics, vol. 8, no. 1, p.011011, 08 2015. [Online]. Available: https://doi.org/10.1115/1.4029923 [113] K. Miura, “Method of packaging and deployment of large membranes in space,”in Semantic Scholar, 1985. [Online]. Available: https://api.semanticscholar.org/CorpusID:109375609 [114] D. Rus and M. T. Tolley, “Design, fabrication and control of origami robots,” NatureReviews Materials, vol. 3, no. 6, pp. 101–112, Jun 2018. [Online]. Available:https://doi.org/10.1038/s41578-018-0009-8 [115] D. A. McAdams and W. Li, “A novel method to design and optimize flat-foldableorigami structures through a genetic algorithm,” Journal of Computing andInformation Science in Engineering, vol. 14, no. 3, p. 031008, 06 2014. [Online].Available: https://doi.org/10.1115/1.4026509 [116] J. T. Overvelde, T. A. de Jong, Y. Shevchenko, S. A. Becerra, G. M. Whitesides,J. C. Weaver, C. Hoberman, and K. Bertoldi, “A three-dimensional actuatedorigami-inspired transformable metamaterial with multiple degrees of freedom,”Nature Communications, vol. 7, no. 1, p. 10929, Mar 2016. [Online]. Available:https://doi.org/10.1038/ncomms10929 [117] S. Wu, Q. Ze, J. Dai, N. Udipi, G. H. Paulino, and R. Zhao, “Stretchable origamirobotic arm with omnidirectional bending and twisting,” Proceedings of the NationalAcademy of Sciences, vol. 118, no. 36, p. e2110023118, 2021. [Online]. Available:https://www.pnas.org/doi/abs/10.1073/pnas.2110023118 [118] J. Liu, X. Chen, Q. Lahondes, K. Esendag, D. Damian, and S. Miyashita, “Origamirobot self-folding by magnetic induction,” in 2022 IEEE/RSJ International Conferenceon Intelligent Robots and Systems (IROS), 2022, pp. 2519–2525. [119] S. Miyashita, S. Guitron, M. Ludersdorfer, C. R. Sung, and D. Rus, “An untetheredminiature origami robot that self-folds, walks, swims, and degrades,” in 2015 IEEEInternational Conference on Robotics and Automation (ICRA), 2015, pp. 1490–1496. [120] K. Zhu, H. Nii, O. N. N. Fernando, and A. D. Cheok, “Selective inductivepowering system for paper computing,” in Proceedings of the 8th InternationalConference on Advances in Computer Entertainment Technology, ser. ACE ’11. NewYork, NY, USA: Association for Computing Machinery, 2011. [Online]. Available:https://doi.org/10.1145/2071423.2071497 [121] M. Boyvat, J.-S. Koh, and R. J. Wood, “Addressable wireless actuation for multijointfolding robots and devices,” Science Robotics, vol. 2, no. 8, p. eaan1544, 2017.[Online]. Available: https://www.science.org/doi/abs/10.1126/scirobotics.aan1544 [122] J. O. Jacobsen, B. G. Winder, L. L. Howell, and S. P. Magleby, “Lamina emergentmechanisms and their basic elements,” Journal of Mechanisms and Robotics, vol. 2,no. 1, p. 011003, 11 2009. [Online]. Available: https://doi.org/10.1115/1.4000523 [123] P. S. Gollnick, S. P. Magleby, and L. L. Howell, “An introduction to multilayer laminaemergent mechanisms,” Journal of Mechanical Design, vol. 133, no. 8, p. 081006, 082011. [Online]. Available: https://doi.org/10.1115/1.4004542 [124] I. L. Delimont, S. P. Magleby, and L. L. Howell, “Evaluating complianthinge geometries for origami-inspired mechanisms,” Journal of Mechanismsand Robotics, vol. 7, no. 1, p. 011009, 02 2015. [Online]. Available:https://doi.org/10.1115/1.4029325 [125] H. Shigemune, S. Maeda, Y. Hara, and S. Hashimoto, “Design of paper mechatronics:Towards a fully printed robot,” in 2014 IEEE/RSJ International Conference onIntelligent Robots and Systems, 2014, pp. 536–541. [126] H. Shigemune, S. Maeda, Y. Hara, N. Hosoya, and S. Hashimoto, “Origami robot:A self-folding paper robot with an electrothermal actuator created by printing,”IEEE/ASME Transactions on Mechatronics, vol. 21, no. 6, pp. 2746–2754, 2016. [127] Y. Li, R. Torah, S. Beeby, and J. Tudor, “An all-inkjet printed flexible capacitor on atextile using a new poly(4-vinylphenol) dielectric ink for wearable applications,” inSENSORS, 2012 IEEE, 2012, pp. 1–4. [128] K. Myny, S. Smout, M. Rockelé, A. Bhoolokam, T. H. Ke, S. Steudel, B. Cobb,A. Gulati, F. G. Rodriguez, K. Obata, M. Marinkovic, D.-V. Pham, A. Hoppe, G. H.Gelinck, J. Genoe, W. Dehaene, and P. Heremans, “A thin-film microprocessor withinkjet print-programmable memory,” Scientific Reports, vol. 4, no. 1, p. 7398, Dec2014. [Online]. Available: https://doi.org/10.1038/srep07398 [129] H. Yasuda, T. Tachi, M. Lee, and J. Yang, “Origami-based tunable truss structures fornon-volatile mechanical memory operation,” Nature Communications, vol. 8, no. 1, p.962, Oct 2017. [Online]. Available: https://doi.org/10.1038/s41467-017-00670-w [130] S. Miyashita, L. Meeker, M. Go¨ldi, Y. Kawahara, and D. Rus, “Self-folding printableelastic electric devices: Resistor, capacitor, and inductor,” in 2014 IEEE InternationalConference on Robotics and Automation (ICRA), 2014, pp. 1446–1453. [131] S. Critcher and T. J. Freeborn, “Flexible pcb failures from dynamic activity and theirimpacts on bioimpedance measurements: A wearable case study,” IEEE Open Journalof Circuits and Systems, vol. 2, pp. 732–742, 2021. [132] S.-W. Hwang, H. Tao, D.-H. Kim, H. Cheng, J.-K. Song, E. Rill, M. A.Brenckle, B. Panilaitis, S. M. Won, Y.-S. Kim, Y. M. Song, K. J. Yu, A. Ameen,R. Li, Y. Su, M. Yang, D. L. Kaplan, M. R. Zakin, M. J. Slepian, Y. Huang,F. G. Omenetto, and J. A. Rogers, “A physically transient form of siliconelectronics,” Science, vol. 337, no. 6102, pp. 1640–1644, 2012. [Online]. Available:https://www.science.org/doi/abs/10.1126/science.1226325 [133] U.S. Food and Drug Administration, “Code of federal regulations, title 21, volume 6,section 582.1431,” 2024. [134] G.-Z. Yang, J. Bellingham, P. E. Dupont, P. Fischer, L. Floridi, R. Full, N. Jacobstein,V. Kumar, M. McNutt, R. Merrifield, B. J. Nelson, B. Scassellati, M. Taddeo,R. Taylor, M. Veloso, Z. L. Wang, and R. Wood, “The grand challenges of <i>sciencerobotics</i>,” Science Robotics, vol. 3, no. 14, p. eaar7650, 2018. [Online]. Available:https://www.science.org/doi/abs/10.1126/scirobotics.aar7650 [135] J. Gao, S. Tian, C. Yuan, Z. Ma, C. Gao, G. Yan, R. Li, Q. Tan, and L. Zhang, “Designand optimization of a novel double-layer helmholtz coil for wirelessly powering acapsule robot,” IEEE Transactions on Power Electronics, vol. 39, no. 1, pp. 1826–1839,2024. [136] S. R. Khan, S. K. Pavuluri, G. Cummins, and M. P. Y. Desmulliez, “Wireless powertransfer techniques for implantable medical devices: A review,” Sensors, vol. 20,no. 12, 2020. [137] S. R. Ruth, M. gu Kim, H. Oda, Z. Wang, Y. Khan, J. Chang, P. M.Fox, and Z. Bao, “Post-surgical wireless monitoring of arterial healthprogression,” iScience, vol. 24, no. 9, p. 103079, 2021. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S2589004221010476 [138] K. Obaideen, L. Albasha, U. Iqbal, and H. Mir, “Wireless power transfer: Applications,challenges, barriers, and the role of ai in achieving sustainable development goals - abibliometric analysis,” Energy Strategy Reviews, vol. 53, p. 101376, 2024. [Online].Available: https://www.sciencedirect.com/science/article/pii/S2211467X2400083X [139] K. Na, H. Jang, H. Ma, and F. Bien, “Tracking optimal efficiency of magnetic resonancewireless power transfer system for biomedical capsule endoscopy,” IEEETransactions on Microwave Theory and Techniques, vol. 63, no. 1, pp. 295–304, 2015. [140] J. Zhiwei, Y. Guozheng, Jiangpingping, W. Zhiwu, and L. Hua, “Efficiencyoptimization of wireless power transmission systems for active capsule endoscopes,”Physiological Measurement, vol. 32, no. 10, p. 1561, aug 2011. [Online]. Available:https://dx.doi.org/10.1088/0967-3334/32/10/005 [141] Y. Palagani, K. Mohanarangam, J. H. Shim, and J. R. Choi, “Wireless power transferanalysis of circular and spherical coils under misalignment conditions for biomedicalimplants,” Biosensors and Bioelectronics, vol. 141, p. 111283, 2019. [Online].Available: https://www.sciencedirect.com/science/article/pii/S0956566319303422 [142] Z. Jia, G. Yan, Y. Shi, and B. Zhu, “A wireless power transmission system for anactive capsule endoscope for colon inspection,” J. Med. Eng. Technol., vol. 36, no. 5,pp. 235–241, Jul. 2012. [143] B. Lenaerts and R. Puers, “An inductive power link for a wireless endoscope,”Biosensors and Bioelectronics, vol. 22, no. 7, pp. 1390–1395, 2007. [Online].Available: https://www.sciencedirect.com/science/article/pii/S0956566306002892 [144] M. R. Basar, M. Y. Ahmad, J. Cho, and F. Ibrahim, “An improved wearable resonantwireless power transfer system for biomedical capsule endoscope,” IEEE Transactionson Industrial Electronics, vol. 65, no. 10, pp. 7772–7781, 2018. [145] S. R. Khan, S. K. Pavuluri, G. Cummins, and M. P. Y. Desmulliez, “Miniaturized 3-dcross-type receiver for wirelessly powered capsule endoscopy,” IEEE Transactions onMicrowave Theory and Techniques, vol. 67, no. 5, pp. 1985–1993, 2019. [146] S. Aldhaher, P. C. K. Luk, and J. F. Whidborne, “Wireless power transfer using class einverter with saturable dc-feed inductor,” in 2013 IEEE Energy Conversion Congressand Exposition, 2013, pp. 1902–1909. [147] H. Liu, Q. Shao, and X. Fang, “Modeling and optimization of class-e amplifier atsubnominal condition in a wireless power transfer system for biomedical implants,”IEEE Transactions on Biomedical Circuits and Systems, vol. 11, no. 1, pp. 35–43,2017. [148] J. Wu, C. Zhao, Z. Lin, J. Du, Y. Hu, and X. He, “Wireless power and data transfer viaa common inductive link using frequency division multiplexing,” IEEE Transactionson Industrial Electronics, vol. 62, no. 12, pp. 7810–7820, 2015. [149] P. Wang, Y. Sun, X. Li, and Z. Ye, “An optimization method for simultaneouswireless power and data transfer systems,” Electronics, vol. 9, no. 12, 2020. [Online].Available: https://www.mdpi.com/2079-9292/9/12/2073 [150] H. Wang and J. Xu, “Research on the efficiency of multiphase wireless power transfersystem with phase-shift control and magnetic field superposition,” InternationalJournal of Electronics, vol. 108, no. 4, pp. 636–646, 2021. [Online]. Available:https://doi.org/10.1080/00207217.2020.1793410 [151] A. Abramson, E. Caffarel-Salvador, V. Soares, D. Minahan, R. Y. Tian, X. Lu, D. Dellal,Y. Gao, S. Kim, J. Wainer, J. Collins, S. Tamang, A. Hayward, T. Yoshitake,H.-C. Lee, J. Fujimoto, J. Fels, M. R. Frederiksen, N. Rahbek, Ulrikand Roxhed,R. Langer, and G. Traverso, “A luminal unfolding microneedle injector for oral deliveryof macromolecules,” Nature Medicine, vol. 25, no. 10, pp. 1512–1518, Oct2019. [152] U.S. Food and Drug Administration, “Code of federal regulations, title 21, volume 3,section 184.1033,” 1994. [153] ——, “Code of federal regulations, title 21, volume 3, section 184.1736,” 1983. [154] F. Fiorillo, Soft Magnetic Materials in Characterization and Measurement of MagneticMaterials. Elsevier, 2004. [155] H. B. Bohidar, “Hydrodynamic properties of gelatin in dilute solutions,” Int. J. Biol.Macromol., vol. 23, no. 1, pp. 1–6, Jul. 1998. [156] J. Kestin, M. Sokolov, and W. A. Wakeham, “Viscosity of liquid water in the range-8 °c to 150 °c,” Journal of Physical and Chemical Reference Data, vol. 7, no. 3, pp.941–948, 1978. [157] B. T. Smith, Solubility and Dissolution in Remington Education: Physical Pharmacy.London: Pharmaceutical Press, 2016. [158] W. J. Bae, J. B. Choi, K. S. Kim, S. J. Kim, H. J. Cho, U. S. Ha, S. H. Hong, J. Y. Lee,and S. W. Kim, “Ab168. evaluation of the biocompatibility of packing materials for acatheter,” Translational Andrology and Urology, vol. 4, no. Suppl 1, 2015. [159] Y. Yang, J. Wang, L. Wang, Q. Wu, L. Ling, Y. Yang, S. Ning, Y. Xie, Q. Cao, L. Li,J. Liu, Q. Ling, and J. Zang, “Magnetic soft robotic bladder for assisted urination,”Science Advances, vol. 8, no. 34, 2022. [160] H. Yuk, C. E. Varela, C. S. Nabzdyk, X. Mao, R. F. Padera, E. T. Roche, and X. Zhao,“Dry double-sided tape for adhesion of wet tissues and devices,” Nature, vol. 575, no.7781, pp. 169–174, Nov 2019. [161] H. Tang and M. Mayersohn, “Porcine prediction of pharmacokinetic parameters inpeople: A pig in a poke?” Drug Metabolism and Disposition, vol. 46, no. 11, pp.1712–1724, 2018. [162] G. Bandini, A. Buffi, M. Marracci, B. Tellini, T. Rizzo, M. Macucci, S. Strangio,and G. Iannaccone, “Electromagnetic design of an inductive wireless power transfersystem for endoscopic capsule,” in 2023 IEEE International Instrumentation andMeasurement Technology Conference (I2MTC), 2023, pp. 1–6."],"dcterms:accessrights":["public"],"dc:title":["Wireless Surgical Capsule Robots for the Gastrointestinal Tract: Towards small scale therapeutic functions without on-board computation"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000233523735"]},"updated_at":"2026-11-18T23:29:21Z"}