{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:36770"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:36770","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Pathology in the gastrointestinal tract causing anaemia- lesion location and the role of capsule endoscopy.","abstract":"Iron deficiency anaemia (IDA) is a common clinical problem in the adult population. The prevalence of pan enteric pathology in IDA is unknown. Oesophagogastroduodenoscopy (OGD) is the gold standard examination, but it can be poorly tolerated and often requires the use of sedation. Meanwhile capsule endoscopy allows us to image the upper gastrointestinal tract (GI) and the small bowel in one sitting and it is well tolerated. The demand for capsule endoscopy is increasing, but evaluation capsule endoscopy videos is time consuming and requires the readers ongoing attention. Preliminary data has shown that the use of artificial intelligence (AI) in capsule endoscopy can significantly reduce reading times. With the growing demand for capsule endoscopy there is a need for biomarkers which can help risk stratify capsule endoscopy referrals. This thesis examines the role of capsule endoscopy in patients with IDA and also evaluated the role of faecal immunochemical test (FIT) for risk stratifying patients for small bowel capsule endoscopy. As part of this thesis, a multicentre prospective study of 170 patients was carried out which investigated the prevalence of pan enteric pathology in patients with IDA. The diagnostic yield of lesions responsible for blood loss on OGD, capsule endoscopy and colonoscopy were 27.6%, 49.4% and 20% respectively (p <0.0001). We also compared the use of magnetically controlled capsule endoscopy (MACE) with OGD in the assessment of the upper gastrointestinal tract prospectively in 158 patients with IDA. This study showed that MACE identified significantly more lesions compared with OGD in the upper GI tract 119 vs 57 (95% CI 0.0- 0.08; P <0.001). No adverse events were recorded and there was no capsule retention. In the setting of IDA and the small bowel, a multicentre prospective study of 128 patients evaluated the role of AI- assisted reading in small bowel (SB) capsule endoscopy. In this study AI- assisted SB reading significantly reduced the reading time [ mean standard read 18.13 min (SD 8.34) vs AI assisted SB reading time 2.27 (SD 2.05) (p<0.0001)]. The per patient diagnostic yield between standard read and AI assisted read was non-inferior [48.4%, 95%CI (40.0- 57.0) vs 53.9%, 95%CI (45.3- 62.3)]. The role of FIT in the detection of small bowel pathology is yet to be defined. In this single centre prospective study the role of FIT in predicting small bowel pathology in 79 patients with IDA was evaluated. We did not find that FIT conferred any additional benefit in the detection of small bowel pathology in patients with IDA, however the diagnostic yield of small bowel capsule endoscopy in patients with IDA is high at 40.2%. In conclusions this thesis supports the use of MACE in the evaluation of the upper GI tract and small bowel in patients with first presentation and /or refractory IDA. It also supports the role of artificial intelligence in SB capsule endoscopy. There is a pressing need for biomarkers to help triage SB capsule endoscopy referrals, however FIT is not a reliable biomarker for the presence of SB pathology in patients with IDA.","abstract_html":"Iron deficiency anaemia (IDA) is a common clinical problem in the adult population. The prevalence of pan enteric pathology in IDA is unknown. Oesophagogastroduodenoscopy (OGD) is the gold standard examination, but it can be poorly tolerated and often requires the use of sedation. Meanwhile capsule endoscopy allows us to image the upper gastrointestinal tract (GI) and the small bowel in one sitting and it is well tolerated. The demand for capsule endoscopy is increasing, but evaluation capsule endoscopy videos is time consuming and requires the readers ongoing attention. Preliminary data has shown that the use of artificial intelligence (AI) in capsule endoscopy can significantly reduce reading times. With the growing demand for capsule endoscopy there is a need for biomarkers which can help risk stratify capsule endoscopy referrals. This thesis examines the role of capsule endoscopy in patients with IDA and also evaluated the role of faecal immunochemical test (FIT) for risk stratifying patients for small bowel capsule endoscopy. As part of this thesis, a multicentre prospective study of 170 patients was carried out which investigated the prevalence of pan enteric pathology in patients with IDA. The diagnostic yield of lesions responsible for blood loss on OGD, capsule endoscopy and colonoscopy were 27.6%, 49.4% and 20% respectively (p &lt;0.0001). We also compared the use of magnetically controlled capsule endoscopy (MACE) with OGD in the assessment of the upper gastrointestinal tract prospectively in 158 patients with IDA. This study showed that MACE identified significantly more lesions compared with OGD in the upper GI tract 119 vs 57 (95% CI 0.0- 0.08; P &lt;0.001). No adverse events were recorded and there was no capsule retention. In the setting of IDA and the small bowel, a multicentre prospective study of 128 patients evaluated the role of AI- assisted reading in small bowel (SB) capsule endoscopy. In this study AI- assisted SB reading significantly reduced the reading time [ mean standard read 18.13 min (SD 8.34) vs AI assisted SB reading time 2.27 (SD 2.05) (p&lt;0.0001)]. The per patient diagnostic yield between standard read and AI assisted read was non-inferior [48.4%, 95%CI (40.0- 57.0) vs 53.9%, 95%CI (45.3- 62.3)]. The role of FIT in the detection of small bowel pathology is yet to be defined. In this single centre prospective study the role of FIT in predicting small bowel pathology in 79 patients with IDA was evaluated. We did not find that FIT conferred any additional benefit in the detection of small bowel pathology in patients with IDA, however the diagnostic yield of small bowel capsule endoscopy in patients with IDA is high at 40.2%. In conclusions this thesis supports the use of MACE in the evaluation of the upper GI tract and small bowel in patients with first presentation and /or refractory IDA. It also supports the role of artificial intelligence in SB capsule endoscopy. There is a pressing need for biomarkers to help triage SB capsule endoscopy referrals, however FIT is not a reliable biomarker for the presence of SB pathology in patients with IDA.","abstract_has_math":false,"creators":["Oka, Priya"],"institution":"University of Sheffield","degree_name":"M.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Sidhu, Reena","Mark, McAlindon","Imran, Aziz"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-12","date_published":"2024-12","updated_at":"2026-11-18T23:29:36Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0009000924055448"],"render_values":[{"text":"0009-0009-2405-5448","href":"https://orcid.org/0009-0009-2405-5448","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/36770/1/Thesis%20with%20corrections240425.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A36770","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sidhu, Reena","Mark, McAlindon","Imran, Aziz"]},{"key":"dc:creator","label":"Author","values":["Oka, Priya"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0009000924055448"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-12"]},{"key":"dc:date.issued","label":"Date","values":["2024-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medicine (Sheffield)","Division of Clinical Medicine, School of Medicine and Population Health"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/36770/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. Goddard AF, James MW, McIntyre AS, Scott BB, Gastroenterology BSo. Guidelines for the management of iron deficiency anaemia. Gut. 2011;60(10):1309-16. 2. Kepczyk T, Kadakia SC. Prospective evaluation of gastrointestinal tract in patients with iron-deficiency anemia. Dig Dis Sci. 1995;40(6):1283-9. 3. Rockey DC, Cello JP. Evaluation of the gastrointestinal tract in patients with iron deficiency anemia. N Engl J Med. 1993;329(23):1691-5. 4. Hardwick RH, Armstrong CP. Synchronous upper and lower gastrointestinal endoscopy is an effective method of investigating iron-deficiency anaemia. Br J Surg. 1997;84(12):1725-8. 5. Niv E, Elis A, Zissin R, Naftali T, Novis B, Lishner M. Iron deficiency anemia in patients without gastrointestinal symptoms--a prospective study. Fam Pract. 2005;22(1):58-61. 6. Wilcox CM, Alexander LN, Clark WS. Prospective evaluation of the gastrointestinal tract in patients with iron deficiency and no systemic or gastrointestinal symptoms or signs. Am J Med. 1997;103(5):405-9. 7. Ching H-L, Phillips V, Healy A, Sidhu R, McAlindon M. PTH-022 A Novel Experience of The Pillcam® ESO 3 Capsule Endoscope In Patients Unwilling To Undergo Conventional Upper GI Endoscopy. Gut. 2016;65(Suppl 1):A228-A. 8. de Franchis R, Eisen GM, Laine L, Fernandez-Urien I, Herrerias JM, Brown RD, et al. Esophageal capsule endoscopy for screening and surveillance of esophageal varices in patients with portal hypertension. Hepatology. 2008;47(5):1595-603. 9. Gutkin E, Shalomov A, Hussain SA, Kim SH, Cortes R, Gray S, et al. Pillcam ESO(®) is more accurate than clinical scoring systems in risk stratifying emergency room patients with acute upper gastrointestinal bleeding. Therap Adv Gastroenterol. 2013;6(3):193-8. 10. Liao Z, Hou X, Lin-Hu EQ, Sheng JQ, Ge ZZ, Jiang B, et al. Accuracy of Magnetically Controlled Capsule Endoscopy, Compared With Conventional Gastroscopy, in Detection of Gastric Diseases. Clin Gastroenterol Hepatol. 2016;14(9):1266-73.e1. 11. Irvine AJ, Sanders DS, Hopper A, Kurien M, Sidhu R. How does tolerability of double balloon enteroscopy compare to other forms of endoscopy? Frontline Gastroenterol. 2016;7(1):41-6. 12. Nemeth A, Wurm Johansson G, Nielsen J, Thorlacius H, Toth E. Capsule retention related to small bowel capsule endoscopy: a large European single-center 10-year clinical experience. United European Gastroenterol J. 2017;5(5):677-86. 13. 14. Lewis BS. Small intestinal bleeding. Gastroenterol Clin North Am. 1994;23(1):67-91. Triester SL, Leighton JA, Leontiadis GI, Fleischer DE, Hara AK, Heigh RI, et al. A meta analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with obscure gastrointestinal bleeding. Am J Gastroenterol. 2005;100(11):2407-18. 15. Koulaouzidis A, Rondonotti E, Giannakou A, Plevris JN. Diagnostic yield of small bowel capsule endoscopy in patients with iron-deficiency anemia: a systematic review. Gastrointest Endosc. 2012;76(5):983-92. 107 16. Page 108 of 129 Li XL, Shen JT, Li YP, Tang CW, Huang LB, Li CC, et al. Capsule endoscopy in diagnosis of small bowel diseases: a health technology assessment. J Evid Based Med. 2014;7(2):84 102. 17. Yung DE, Rondonotti E, Giannakou A, Avni T, Rosa B, Toth E, et al. Capsule endoscopy in young patients with iron deficiency anaemia and negative bidirectional gastrointestinal endoscopy. United European Gastroenterol J. 2017;5(7):974-81. 18. Hale MF, Rahman I, Drew K, Sidhu R, Riley SA, Patel P, et al. Magnetically steerable gastric capsule endoscopy is equivalent to flexible endoscopy in the detection of markers in an excised porcine stomach model: results of a randomized trial. Endoscopy. 2015;47(7):650-3. 19. Hale MF, Drew K, Sidhu R, McAlindon ME. Does magnetically assisted capsule endoscopy improve small bowel capsule endoscopy completion rate? A randomised controlled trial. Endosc Int Open. 2016;4(2):E215-21. 20. Saurin J-C, Lapalus MG, Cholet F, D’Halluin PN, Filoche B, Gaudric M, et al. Can we shorten the small-bowel capsule reading time with the “Quick-view” image detection system? Digestive and liver disease. 2012;44(6):477-81. 21. Westerhof J, Koornstra JJ, Weersma RK. Can we reduce capsule endoscopy reading times? Gastrointestinal endoscopy. 2009;69(3):497-502. 22. Hosoe N, Rey J-F, Imaeda H, Bessho R, Ichikawa R, Ida Y, et al. Evaluations of capsule endoscopy software in reducing the reading time and the rate of false negatives by inexperienced endoscopists. Clinics and research in hepatology and gastroenterology. 2012;36(1):66-71. 23. Leenhardt R, Vasseur P, Li C, Saurin JC, Rahmi G, Cholet F, et al. A neural network algorithm for detection of GI angiectasia during small-bowel capsule endoscopy. Gastrointestinal endoscopy. 2019;89(1):189-94. 24. Ding Z, Shi H, Zhang H, Meng L, Fan M, Han C, et al. Gastroenterologist-Level Identification of Small-Bowel Diseases and Normal Variants by Capsule Endoscopy Using a Deep-Learning Model. Gastroenterology. 2019;157(4):1044-54.e5. 25. Spada C, Piccirelli S, Hassan C, Ferrari C, Toth E, González-Suárez B, et al. AI-assisted capsule endoscopy reading in suspected small bowel bleeding: a multicentre prospective study. The Lancet Digital Health. 2024;6(5):e345-e53. 26. Young GP, Symonds EL, Allison JE, Cole SR, Fraser CG, Halloran SP, et al. Advances in Fecal Occult Blood Tests: the FIT revolution. Dig Dis Sci. 2015;60(3):609-22. 27. Grobbee EJ, Wisse PHA, Schreuders EH, van Roon A, van Dam L, Zauber AG, et al. Guaiac-based faecal occult blood tests versus faecal immunochemical tests for colorectal cancer screening in average-risk individuals. Cochrane Database Syst Rev. 2022;6(6):CD009276. 28. Brenner H, Tao S. Superior diagnostic performance of faecal immunochemical tests for haemoglobin in a head-to-head comparison with guaiac based faecal occult blood test among 2235 participants of screening colonoscopy. Eur J Cancer. 2013;49(14):3049-54. 29. Kuipers EJ, Rösch T, Bretthauer M. Colorectal cancer screening--optimizing current strategies and new directions. Nat Rev Clin Oncol. 2013;10(3):130-42. 30. Schreuders EH, Ruco A, Rabeneck L, Schoen RE, Sung JJ, Young GP, et al. Colorectal cancer screening: a global overview of existing programmes. Gut. 2015;64(10):1637-49. 31. Nieuwenburg SAV, Vuik FER, Kruip MJHA, Kuipers EJ, Spaander MCW. Effect of anticoagulants and NSAIDs on accuracy of faecal immunochemical tests (FITs) in colorectal cancer screening: a systematic review and meta-analysis. Gut. 2019;68(5):866-72. 108 32. Page 109 of 129 Allison JE, Fraser CG, Halloran SP, Young GP. Population screening for colorectal cancer means getting FIT: the past, present, and future of colorectal cancer screening using the fecal immunochemical test for hemoglobin (FIT). Gut Liver. 2014;8(2):117-30. 33. Cole SR, Young GP, Esterman A, Cadd B, Morcom J. A Randomised Trial of the Impact of New Faecal Haemoglobin Test Technologies on Population Participation in Screening for Colorectal Cancer. Journal of Medical Screening. 2003;10(3):117-22. 34. Chapman C, Bunce J, Oliver S, Ng O, Tangri A, Rogers R, et al. Service evaluation of faecal immunochemical testing and anaemia for risk stratification in the 2-week-wait pathway for colorectal cancer. BJS Open. 2019;3(3):395-402. 35. Monahan KJ, Davies MM, Abulafi M, Banerjea A, Nicholson BD, Arasaradnam R, et al. Faecal immunochemical testing (FIT) in patients with signs or symptoms of suspected colorectal cancer (CRC): a joint guideline from the Association of Coloproctology of Great Britain and Ireland (ACPGBI) and the British Society of Gastroenterology (BSG). Gut. 2022;71(10):1939-62. 36. Park JJ, Cheon JH. Small bowel evaluation in asymptomatic fecal immunochemical test-positive patients with a negative colonoscopy: is it necessary? Dig Dis Sci. 2011;56(10):2773-5. 37. Levi Z, Rozen P, Hazazi R, Vilkin A, Waked A, Maoz E, et al. A quantitative immunochemical fecal occult blood test for colorectal neoplasia. Ann Intern Med. 2007;146(4):244-55. 38. Park DI, Ryu S, Kim YH, Lee SH, Lee CK, Eun CS, et al. Comparison of guaiac-based and quantitative immunochemical fecal occult blood testing in a population at average risk undergoing colorectal cancer screening. Am J Gastroenterol. 2010;105(9):2017-25. 39. McQuaid KR, Laine L. A systematic review and meta-analysis of randomized, controlled trials of moderate sedation for routine endoscopic procedures. Gastrointest Endosc. 2008;67(6):910-23. 40. Crooks CJ, Card TR, West J. The risk of unexpected hospital admissions and primary care visits after an elective day-case gastroscopy: A cohort study within England. Aliment Pharmacol Ther. 2022. 41. Ravindran S, Bassett P, Shaw T, Dron M, Broughton R, Johnston D, et al. National census of UK endoscopy services in 2019. Frontline Gastroenterol. 2021;12(6):451-60. 42. Ford AC, Marwaha A, Lim A, Moayyedi P. What is the prevalence of clinically significant endoscopic findings in subjects with dyspepsia? Systematic review and meta analysis. Clin Gastroenterol Hepatol. 2010;8(10):830-7, 7.e1-2. 43. Tai FWD, Wray N, Sidhu R, Hopper A, McAlindon M. Factors associated with oesophagogastric cancers missed by gastroscopy: a case-control study. Frontline Gastroenterol. 2020;11(3):194-201. 44. Moayyedi P, Tepper J, Hilsden R, Rabeneck L. International comparisons of manpower in gastroenterology. Am J Gastroenterol. 2007;102(3):478-81. 45. Hori S, Tsuda K, Murayama S, Matsushita M, Yukawa K, Kozuka T. CT of gastric carcinoma: preliminary results with a new scanning technique. Radiographics. 1992;12(2):257-68. 46. Minami M, Kawauchi N, Itai Y, Niki T, Sasaki Y. Gastric tumors: radiologic-pathologic correlation and accuracy of T staging with dynamic CT. Radiology. 1992;185(1):173-8. 47. Low VH, Levine MS, Rubesin SE, Laufer I, Herlinger H. Diagnosis of gastric carcinoma: sensitivity of double-contrast barium studies. AJR Am J Roentgenol. 1994;162(2):329-34. 109 48. Page 110 of 129 Levine MS, Chu P, Furth EE, Rubesin SE, Laufer I, Herlinger H. Carcinoma of the esophagus and esophagogastric junction: sensitivity of radiographic diagnosis. AJR Am J Roentgenol. 1997;168(6):1423-6. 49. Khanderia E, Markar SR, Acharya A, Kim Y, Kim YW, Hanna GB. The Influence of Gastric Cancer Screening on the Stage at Diagnosis and Survival: A Meta-Analysis of Comparative Studies in the Far East. J Clin Gastroenterol. 2016;50(3):190-7. 50. Kim JW, Shin SS, Heo SH, Lim HS, Lim NY, Park YK, et al. The role of three dimensional multidetector CT gastrography in the preoperative imaging of stomach cancer: emphasis on detection and localization of the tumor. Korean J Radiol. 2015;16(1):80-9. 51. Kim JH, Park SH, Hong HS, Auh YH. CT gastrography. Abdom Imaging. 2005;30(5):509-17. 52. Bouchard S, Ibrahim M, Van Gossum A. Video capsule endoscopy: perspectives of a revolutionary technique. World J Gastroenterol. 2014;20(46):17330-44. 53. Ching HL, Healy A, Thurston V, Hale MF, Sidhu R, McAlindon ME. Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience. World J Gastroenterol. 2018;24(26):2893-901. 54. Park J, Cho YK, Kim JH. Current and Future Use of Esophageal Capsule Endoscopy. Clin Endosc. 2018;51(4):317-22. 55. Bhardwaj A, Hollenbeak CS, Pooran N, Mathew A. A meta-analysis of the diagnostic accuracy of esophageal capsule endoscopy for Barrett's esophagus in patients with gastroesophageal reflux disease. Am J Gastroenterol. 2009;104(6):1533-9. 56. Liu L, Towfighian S, Hila A. A Review of Locomotion Systems for Capsule Endoscopy. IEEE Rev Biomed Eng. 2015;8:138-51. 57. Koulaouzidis A, Iakovidis DK, Karargyris A, Rondonotti E. Wireless endoscopy in 2020: Will it still be a capsule? World J Gastroenterol. 2015;21(17):5119-30. 58. Carpi F, Galbiati S, Carpi A. Magnetic shells for gastrointestinal endoscopic capsules as a means to control their motion. Biomed Pharmacother. 2006;60(8):370-4. 59. Ching HL, Hale MF, Sidhu R, Beg S, Ragunath K, McAlindon ME. Magnetically assisted capsule endoscopy in suspected acute upper GI bleeding versus esophagogastroduodenoscopy in detecting focal lesions. Gastrointest Endosc. 2019;90(3):430-9. 60. Rahman I, Pioche M, Shim CS, Lee SP, Sung IK, Saurin JC, et al. Magnetic-assisted capsule endoscopy in the upper GI tract by using a novel navigation system (with video). Gastrointest Endosc. 2016;83(5):889-95.e1. 61. Ching HL, Hale MF, Kurien M, Campbell JA, Chetcuti Zammit S, Healy A, et al. Diagnostic yield of magnetically assisted capsule endoscopy versus gastroscopy in recurrent and refractory iron deficiency anemia. Endoscopy. 2019;51(5):409-18. 62. Denzer UW, Rösch T, Hoytat B, Abdel-Hamid M, Hebuterne X, Vanbiervielt G, et al. Magnetically guided capsule versus conventional gastroscopy for upper abdominal complaints: a prospective blinded study. J Clin Gastroenterol. 2015;49(2):101-7. 63. Qian YY, Zhu SG, Hou X, Zhou W, An W, Su XJ, et al. Preliminary study of magnetically controlled capsule gastroscopy for diagnosing superficial gastric neoplasia. Dig Liver Dis. 2018;50(10):1041-6. 64. Zhao AJ, Qian YY, Sun H, Hou X, Pan J, Liu X, et al. Screening for gastric cancer with magnetically controlled capsule gastroscopy in asymptomatic individuals. Gastrointest Endosc. 2018;88(3):466-74.e1. 110 65. Page 111 of 129 Ching HL, Hale MF, Sidhu R, McAlindon ME. Reassessing the value of gastroscopy for the investigation of dyspepsia. Frontline Gastroenterol. 2018;9(1):62-6. 66. Kelvin FM, Maglinte DD. Enteroclysis or small bowel follow-through in Crohn' s diseases? Gastroenterology. 1998;114(6):1349-51. 67. Panes J, Bouhnik Y, Reinisch W, Stoker J, Taylor SA, Baumgart DC, et al. Imaging techniques for assessment of inflammatory bowel disease: joint ECCO and ESGAR evidence based consensus guidelines. J Crohns Colitis. 2013;7(7):556-85. 68. Ahmed O, Rodrigues DM, Nguyen GC. Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis. Can J Gastroenterol Hepatol. 2016;2016:7857352. 69. Pennazio M, Spada C, Eliakim R, Keuchel M, May A, Mulder CJ, et al. Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline. Endoscopy. 2015;47(4):352-76. 70. Dolak W, Kulnigg-Dabsch S, Evstatiev R, Gasche C, Trauner M, Püspök A. A randomized head-to-head study of small-bowel imaging comparing MiroCam and EndoCapsule. Endoscopy. 2012;44(11):1012-20. 71. Hartmann D, Eickhoff A, Damian U, Riemann JF. Diagnosis of small-bowel pathology using paired capsule endoscopy with two different devices: a randomized study. Endoscopy. 2007;39(12):1041-5. 72. Cave DR, Fleischer DE, Leighton JA, Faigel DO, Heigh RI, Sharma VK, et al. A multicenter randomized comparison of the Endocapsule and the Pillcam SB. Gastrointest Endosc. 2008;68(3):487-94. 73. Pioche M, Gaudin JL, Filoche B, Jacob P, Lamouliatte H, Lapalus MG, et al. Prospective, randomized comparison of two small-bowel capsule endoscopy systems in patients with obscure GI bleeding. Gastrointest Endosc. 2011;73(6):1181-8. 74. Riccioni ME, Urgesi R, Spada C, Cianci R, Pelecca G, Bizzotto A, et al. Unexplained iron deficiency anaemia: Is it worthwhile to perform capsule endoscopy? Dig Liver Dis. 2010;42(8):560-6. 75. Milano A, Balatsinou C, Filippone A, Caldarella MP, Laterza F, Lapenna D, et al. A prospective evaluation of iron deficiency anemia in the GI endoscopy setting: role of standard endoscopy, videocapsule endoscopy, and CT-enteroclysis. Gastrointest Endosc. 2011;73(5):1002-8. 76. Liao Z, Gao R, Xu C, Li ZS. Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. Gastrointest Endosc. 2010;71(2):280-6. 77. Yung DE, Rondonotti E, Sykes C, Pennazio M, Plevris JN, Koulaouzidis A. Systematic review and meta-analysis: is bowel preparation still necessary in small bowel capsule endoscopy? Expert Rev Gastroenterol Hepatol. 2017;11(10):979-93. 78. Rokkas T, Papaxoinis K, Triantafyllou K, Pistiolas D, Ladas SD. Does purgative preparation influence the diagnostic yield of small bowel video capsule endoscopy?: A meta-analysis. Am J Gastroenterol. 2009;104(1):219-27. 79. Katsinelos P, Fasoylas K, Chatzimavroudis G, Lazaraki G, Zavos C, Pilpilidis I, et al. Diagnostic yield and clinical management after capsule endoscopy in daily clinical practice: A single-center experience. Hippokratia. 2010;14(4):271-6. 111 80. Page 112 of 129 Ramirez FC, Shaukat MS, Young MA, Johnson DA, Akins R. Feasibility and safety of string, wireless capsule endoscopy in the diagnosis of Barrett's esophagus. Gastrointest Endosc. 2005;61(6):741-6. 81. Singh A, Marshall C, Chaudhuri B, Okoli C, Foley A, Person SD, et al. Timing of video capsule endoscopy relative to overt obscure GI bleeding: implications from a retrospective study. Gastrointest Endosc. 2013;77(5):761-6. 82. Rondonotti E, Soncini M, Girelli C, Ballardini G, Bianchi G, Brunati S, et al. Small bowel capsule endoscopy in clinical practice: a multicenter 7-year survey. Eur J Gastroenterol Hepatol. 2010;22(11):1380-6. 83. Cheung DY, Kim JS, Shim KN, Choi MG, Group KGIS. The Usefulness of Capsule Endoscopy for Small Bowel Tumors. Clin Endosc. 2016;49(1):21-5. 84. Pasha SF, Pennazio M, Rondonotti E, Wolf D, Buras MR, Albert JG, et al. Capsule Retention in Crohn's Disease: A Meta-analysis. Inflamm Bowel Dis. 2020;26(1):33-42. 85. Caunedo-Alvarez A, Romero-Vazquez J, Herrerias-Gutierrez JM. Patency and Agile capsules. World J Gastroenterol. 2008;14(34):5269-73. 86. Rozendorn N, Klang E, Lahat A, Yablecovitch D, Kopylov U, Eliakim A, et al. Prediction of patency capsule retention in known Crohn's disease patients by using magnetic resonance imaging. Gastrointest Endosc. 2016;83(1):182-7. 87. Zagorowicz ES, Pietrzak AM, Wronska E, Pachlewski J, Rutkowski P, Kraszewska E, et al. Small bowel tumors detected and missed during capsule endoscopy: single center experience. World J Gastroenterol. 2013;19(47):9043-8. 88. Kim TJ, Kim ER, Chang DK, Kim YH, Hong SN. Comparison of the Efficacy and Safety of Single- versus Double-Balloon Enteroscopy Performed by Endoscopist Experts in Single Balloon Enteroscopy: A Single-Center Experience and Meta-Analysis. Gut Liver. 2017;11(4):520-7. 89. Cooper GS, Kou TD, Rex DK. Complications following colonoscopy with anesthesia assistance: a population-based analysis. JAMA Intern Med. 2013;173(7):551-6. 90. Wang P, Xu T, Ngamruengphong S, Makary MA, Kalloo A, Hutfless S. Rates of infection after colonoscopy and osophagogastroduodenoscopy in ambulatory surgery centres in the USA. Gut. 2018;67(9):1626-36. 91. Zhao S, Wang S, Pan P, Xia T, Chang X, Yang X, et al. Magnitude, Risk Factors, and Factors Associated With Adenoma Miss Rate of Tandem Colonoscopy: A Systematic Review and Meta-analysis. Gastroenterology. 2019;156(6):1661-74.e11. 92. Moss S, Mathews C, Day TJ, Smith S, Seaman HE, Snowball J, et al. Increased uptake and improved outcomes of bowel cancer screening with a faecal immunochemical test: results from a pilot study within the national screening programme in England. Gut. 2017;66(9):1631-44. 93. Palmer CK, Thomas MC, von Wagner C, Raine R. Reasons for non-uptake and subsequent participation in the NHS Bowel Cancer Screening Programme: a qualitative study. Br J Cancer. 2014;110(7):1705-11. 94. Al-Najami I, Rancinger CP, Larsen MK, Spolén E, Baatrup G. The Diagnostic Yield of Colonoscopy Stratified by Indications. Gastroenterol Res Pract. 2017;2017:4910143. 95. Gavin DR, Valori RM, Anderson JT, Donnelly MT, Williams JG, Swarbrick ET. The national colonoscopy audit: a nationwide assessment of the quality and safety of colonoscopy in the UK. Gut. 2013;62(2):242-9. 112 96. Page 113 of 129 Deding U, Kaalby L, Bøggild H, Plantener E, Wollesen MK, Kobaek-Larsen M, et al. Colon Capsule Endoscopy vs. CT Colonography Following Incomplete Colonoscopy: A Systematic Review with Meta-Analysis. Cancers (Basel). 2020;12(11). 97. Pickhardt PJ, Correale L, Morra L, Regge D, Hassan C. JOURNAL CLUB: Extracolonic Findings at CT Colonography: Systematic Review and Meta-Analysis. AJR Am J Roentgenol. 2018;211(1):25-39. 98. Spada C, Hassan C, Bellini D, Burling D, Cappello G, Carretero C, et al. Imaging alternatives to colonoscopy: CT colonography and colon capsule. European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastrointestinal and Abdominal Radiology (ESGAR) Guideline - Update 2020. Eur Radiol. 2021;31(5):2967-82. 99. Vuik FER, Nieuwenburg SAV, Moen S, Spada C, Senore C, Hassan C, et al. Colon capsule endoscopy in colorectal cancer screening: a systematic review. Endoscopy. 2021;53(8):815-24. 100. Möllers T, Schwab M, Gildein L, Hoffmeister M, Albert J, Brenner H, et al. Second generation colon capsule endoscopy for detection of colorectal polyps: Systematic review and meta-analysis of clinical trials. Endosc Int Open. 2021;9(4):E562-E71. 101. Spada C, Barbaro F, Andrisani G, Minelli Grazioli L, Hassan C, Costamagna I, et al. Colon capsule endoscopy: What we know and what we would like to know. World J Gastroenterol. 2014;20(45):16948-55. 102. Ismail MS, Murphy G, Semenov S, McNamara D. Comparing Colon Capsule Endoscopy to colonoscopy; a symptomatic patient's perspective. BMC Gastroenterol. 2022;22(1):31. 103. Spada C, Hassan C, Galmiche JP, Neuhaus H, Dumonceau JM, Adler S, et al. Colon capsule endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline. Endoscopy. 2012;44(5):527-36. 104. Baltes P, Bota M, Albert J, Philipper M, Hörster HG, Hagenmüller F, et al. PillCamColon2 after incomplete colonoscopy - A prospective multicenter study. World J Gastroenterol. 2018;24(31):3556-66. 105. NHS. Clinical guide for using colon capsule endoscopy in the lower gastrointestinal pathway. https://www.nice.org.uk/Media/Default/About/COVID-19/Specialty guides/triaging-patients-with-lower-gi-symptoms.pdf (access March 31, 2021).November 2020. [ 106. MacLeod C, Hudson J, Brogan M, Cotton S, Treweek S, MacLennan G, et al. ScotCap - A large observational cohort study. Colorectal Dis. 2022;24(4):411-21. 107. Deding U, Kaalby L, Baatrup G, Kobaek-Larsen M, Thygesen MK, Epstein O, et al. The Effect of Prucalopride on the Completion Rate and Polyp Detection Rate of Colon Capsule Endoscopies. Clin Epidemiol. 2022;14:437-44. 108. Bruining DH, Oliva S, Fleisher MR, Fischer M, Fletcher JG, group Bs. Panenteric capsule endoscopy versus ileocolonoscopy plus magnetic resonance enterography in Crohn's disease: a multicentre, prospective study. BMJ Open Gastroenterol. 2020;7(1). 109. Cosnes J, Gower-Rousseau C, Seksik P, Cortot A. Epidemiology and natural history of inflammatory bowel diseases. Gastroenterology. 2011;140(6):1785-94. 110. Yamamoto T, Watanabe T. Surgery for luminal Crohn's disease. World J Gastroenterol. 2014;20(1):78-90. 111. Meister T, Heinzow HS, Domagk D, Dortgolz A, Lenze F, Ross M, et al. Colon capsule endoscopy versus standard colonoscopy in assessing disease activity of ulcerative colitis: a prospective trial. Tech Coloproctol. 2013;17(6):641-6. 113 Page 114 of 129 112. Sung J, Ho KY, Chiu HM, Ching J, Travis S, Peled R. The use of Pillcam Colon in assessing mucosal inflammation in ulcerative colitis: a multicenter study. Endoscopy. 2012;44(8):754-8. 113. Mehdizadeh S, Chen GC, Barkodar L, Enayati PJ, Pirouz S, Yadegari M, et al. Capsule endoscopy in patients with Crohn's disease: diagnostic yield and safety. Gastrointest Endosc. 2010;71(1):121-7. 114. Eliakim R, Spada C, Lapidus A, Eyal I, Pecere S, Fernández-Urién I, et al. Evaluation of a new pan-enteric video capsule endoscopy system in patients with suspected or established inflammatory bowel disease - feasibility study. Endosc Int Open. 2018;6(10):E1235-E46. 115. Snook J, Bhala N, Beales ILP, Cannings D, Kightley C, Logan RP, et al. British Society of Gastroenterology guidelines for the management of iron deficiency anaemia in adults. Gut. 2021;70(11):2030-51. 116. Landy J, Macfarlane B. Synchronous bidirectional endoscopy for iron deficiency anaemia: is it appropriate for patients under 50? Postgraduate Medical Journal. 2010;86(1016):338-40. 117. Urquhart J, Eisen G, Faigel DO, Mattek N, Holub J, Lieberman DA. A closer look at same-day bidirectional endoscopy. Gastrointestinal Endoscopy. 2009;69(2):271-7. 118. Stone H, Almilaji O, John C, Smith C, Surgenor SL, Ayres L, et al. The dedicated iron deficiency anaemia clinic: a 15-year experience. Frontline Gastroenterol. 2022;13(1):20-4. 119. McIntyre AS, Long RG. Prospective survey of investigations in outpatients referred with iron deficiency anaemia. Gut. 1993;34(8):1102-7. 120. Pengelly S, Fabricius M, McMenamin D, Wu E, Metzner M, Lewis SJ, et al. Attendance at iron deficiency anaemia clinic: audit of outcomes 5 years on. Colorectal Dis. 2013;15(4):423-7. 121. Cappellini MD, Motta I. Anemia in Clinical Practice-Definition and Classification: Does Hemoglobin Change With Aging? Semin Hematol. 2015;52(4):261-9. 122. Saurin JC, Delvaux M, Gaudin JL, Fassler I, Villarejo J, Vahedi K, et al. Diagnostic value of endoscopic capsule in patients with obscure digestive bleeding: blinded comparison with video push-enteroscopy. Endoscopy. 2003;35(7):576-84. 123. Annibale B, Capurso G, Chistolini A, D’Ambra G, DiGiulio E, Monarca B, et al. Gastrointestinal causes of refractory iron deficiency anemia in patients without gastrointestinal symptoms. The American journal of medicine. 2001;111(6):439-45. 124. Majid S, Salih M, Wasaya R, Jafri W. Predictors of gastrointestinal lesions on endoscopy in iron deficiency anemia without gastrointestinal symptoms. BMC Gastroenterology. 2008;8(1):52. 125. Yates JM, Logan ECM, Stewart RM. Iron deficiency anaemia in general practice: clinical outcomes over three years and factors influencing diagnostic investigations. Postgraduate Medical Journal. 2004;80(945):405-10. 126. Johnston C, Yung D, Joshi A, Plevris J, Koulaouzidis A. Small bowel malignancy in patients undergoing capsule endoscopy at a tertiary care academic center: Case series and review of the literature. Endoscopy International Open. 2017;05(06):E463-E70. 127. Sidhu PS, McAlindon ME, Drew K, Sidhu R. The Utility of Capsule Endoscopy in Patients under 50 Years of Age with Recurrent Iron Deficiency Anaemia: Is the Juice Worth the Squeeze? Gastroenterol Res Pract. 2015;2015:948574. 114 Page 115 of 129 128. Silva AC, Sheppard ZA, Surgenor SL, Williams EJ, Thomas PW, Snook JA. Clinical risk factors for underlying gastrointestinal malignancy in iron deficiency anaemia: the IDIOM study. Frontline Gastroenterology. 2014;5(4):237-42. 129. James MW, Chen CM, Goddard WP, Scott BB, Goddard AF. Risk factors for gastrointestinal malignancy in patients with iron-deficiency anaemia. Eur J Gastroenterol Hepatol. 2005;17(11):1197-203. 130. Kepczyk MT, Kadakia CSC. Prospective evaluation of gastrointestinal tract in patients with iron-deficiency anemia. Digestive Diseases and Sciences. 1995;40(6):1283-9. 131. Zaman A, Katon RM. Push enteroscopy for obscure gastrointestinal bleeding yields a high incidence of proximal lesions within reach of a standard endoscope. Gastrointest Endosc. 1998;47(5):372-6. 132. Descamps C, Schmit A, Van Gossum A. \"Missed\" upper gastrointestinal tract lesions may explain \"occult\" bleeding. Endoscopy. 1999;31(6):452-5. 133. Crooks CJ, Card TR, West J. The risk of unexpected hospital admissions and primary care visits after an elective day‐case gastroscopy: a cohort study within England. Alimentary Pharmacology & Therapeutics. 2022;56(1):56-66. 134. Campo R, Brullet E, Montserrat A, Calvet X, Moix J, Rué M, et al. Identification of factors that influence tolerance of upper gastrointestinal endoscopy. Eur J Gastroenterol Hepatol. 1999;11(2):201-4. 135. E. Mulcahy PK, M. R. Banks,, H. Factors Associated with Tolerance to, and Discomfort with, Unsedated Diagnostic Gastroscopy. Scandinavian Journal of Gastroenterology. 2001;36(12):1352-7. 136. Macleod C, Hudson J, Brogan M, Cotton S, Treweek S, Maclennan G, et al. ScotCap – A large observational cohort study. Colorectal Disease. 2022;24(4):411-21. 137. Rosa B, Andrade P, Lopes S, Gonçalves AR, Serrazina J, Marílio Cardoso P, et al. Pan Enteric Capsule Endoscopy: Current Applications and Future Perspectives. GE Port J Gastroenterol. 2024;31(2):89-100. 138. Liao Z, Duan XD, Xin L, Bo LM, Wang XH, Xiao GH, et al. Feasibility and safety of magnetic-controlled capsule endoscopy system in examination of human stomach: a pilot study in healthy volunteers. J Interv Gastroenterol. 2012;2(4):155-60. 139. Zou WB, Hou XH, Xin L, Liu J, Bo LM, Yu GY, et al. Magnetic-controlled capsule endoscopy vs. gastroscopy for gastric diseases: a two-center self-controlled comparative trial. Endoscopy. 2015;47(6):525-8. 140. Jiang B, Qian YY, Pan J, Jiang X, Wang YC, Zhu JH, et al. Second-generation magnetically controlled capsule gastroscopy with improved image resolution and frame rate: a randomized controlled clinical trial (with video). Gastrointest Endosc. 2020;91(6):1379-87. 141. Zhu SG, Qian YY, Tang XY, Zhu QQ, Zhou W, Du H, et al. Gastric preparation for magnetically controlled capsule endoscopy: A prospective, randomized single-blinded controlled trial. Dig Liver Dis. 2018;50(1):42-7. 142. Jiang X, Pan J, Li Z-S, Liao Z. Standardized examination procedure of magnetically controlled capsule endoscopy. VideoGIE. 2019;4(6):239-43. 143. Spencer HL, Lobo AJ, Riley SA. Variations in the reporting of endoscopies by different endoscopists. Clin Med (Lond). 2007;7(1):23-7. 144. Pimenta-Melo AR, Monteiro-Soares M, Libânio D, Dinis-Ribeiro M. Missing rate for gastric cancer during upper gastrointestinal endoscopy: a systematic review and meta analysis. European journal of gastroenterology & hepatology. 2016;28(9):1041-9. 115 Page 116 of 129 145. Teh JL, Tan JR, Lau LJ, Saxena N, Salim A, Tay A, et al. Longer examination time improves detection of gastric cancer during diagnostic upper gastrointestinal endoscopy. Clin Gastroenterol Hepatol. 2015;13(3):480-7.e2. 146. Park JM, Huo SM, Lee HH, Lee B-I, Song HJ, Choi M-G. Longer Observation Time Increases Proportion of Neoplasms Detected by Esophagogastroduodenoscopy. Gastroenterology. 2017;153(2):460-9.e1. 147. Tai FWD, Ching HL, Sloan M, Sidhu R, Mcalindon M. Comparison of patient tolerance and acceptability of magnet-controlled capsule endoscopy and flexible endoscopy in the investigation of dyspepsia. Endoscopy International Open. 2022;10(06):E735-E44. 148. Tai FWD, Healy A, Thokala P, Chetcuti Zammit S, Sidhu R, McAlindon M. Cost comparison of oral, transnasal and magnet assisted capsule endoscopy in the examination of the upper gastrointestinal tract in patients with dyspepsia. Frontline gastroenterology. 2022;14(4):300-5. 149. YF X, ZX W, He S Zhou YY ZY, He JL, Peng X, Yang ZX, Lv QJ, Yang H BJ, Fan CQ, Tang B, Hu CJ, Jie MM, Liu E, Lin H, Koulaouzidis A, XY Z. Fully automated magnetically controlled capsule endoscopy for examination of the stomach and small bowel: a prospective, feasibility, two-centre study.2021; 6(11):[914- 21 pp.]. 150. Meltzer AC, Kumar A, Kallus SJ, Schueler SA, Mattu N, Ma Y, et al. Magnetically controlled capsule for assessment of the gastric mucosa in symptomatic patients: a prospective, single-arm, single-center, comparative study. IGIE. 2023;2(2):139-47. 151. Wang S, Huang Y, Hu W, Mao H, McAlindon ME, Liu Y, et al. Detachable string magnetically controlled capsule endoscopy for detecting high-risk varices in compensated advanced chronic liver disease (CHESS1801): A prospective multicenter study. Lancet Reg Health West Pac. 2021;6:100072. 152. McAlindon ME. String used for oesophageal capsule endoscopy: help or hindrance? Eur J Gastroenterol Hepatol. 2024;36(12):1470-1. 153. Yu Y, Liao Z, Jiang X, Pan J, Zhou W, Lau JYW. The use of magnet‐controlled capsule endoscopy as the initial diagnostic tool in patients with acute upper gastrointestinal bleeding. Journal of Gastroenterology and Hepatology. 2023;38(11):2027-34. 154. Iddan G, Meron G, Glukhovsky A, Swain P. Wireless capsule endoscopy. Nature. 2000;405(6785):417. 155. Ebigbo A, Mendel R, Probst A, Manzeneder J, Souza Jr LAD, Papa JP, et al. Computer aided diagnosis using deep learning in the evaluation of early oesophageal adenocarcinoma. Gut. 2019;68(7):1143-5. 156. Hirasawa T, Aoyama K, Tanimoto T, Ishihara S, Shichijo S, Ozawa T, et al. Application of artificial intelligence using a convolutional neural network for detecting gastric cancer in endoscopic images. Gastric Cancer. 2018;21(4):653-60. 157. Beg S, Wronska E, Araujo I, González Suárez B, Ivanova E, Fedorov E, et al. Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy. Gastrointest Endosc. 2020;91(6):1322-7. 158. Piccirelli S, Mussetto A, Bellumat A, Cannizzaro R, Pennazio M, Pezzoli A, et al. New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times. Diagnostics. 2022;12(8):1783. 159. Tsuboi A, Oka S, Aoyama K, Saito H, Aoki T, Yamada A, et al. Artificial intelligence using a convolutional neural network for automatic detection of small‐bowel angioectasia in capsule endoscopy images. Digestive Endoscopy. 2020;32(3):382-90. 116 Page 117 of 129 160. Pennazio M, Rondonotti E, Despott EJ, Dray X, Keuchel M, Moreels T, et al. Small bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2022. Endoscopy. 2023;55(1):58-95. 161. Lai LH, Wong GL, Chow DK, Lau JY, Sung JJ, Leung WK. Inter-observer variations on interpretation of capsule endoscopies. Eur J Gastroenterol Hepatol. 2006;18(3):283-6. 162. Guralnik JM, Eisenstaedt RS, Ferrucci L, Klein HG, Woodman RC. Prevalence of anemia in persons 65 years and older in the United States: evidence for a high rate of unexplained anemia. Blood. 2004;104(8):2263-8. 163. Lopez A, Cacoub P, Macdougall IC, Peyrin-Biroulet L. Iron deficiency anaemia. Lancet. 2016;387(10021):907-16. 164. Pasricha SR, Tye-Din J, Muckenthaler MU, Swinkels DW. Iron deficiency. Lancet. 2021;397(10270):233-48. 165. Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig L, et al. STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. BMJ. 2015;351:h5527. 166. Rosa B, Margalit-Yehuda R, Gatt K, Sciberras M, Girelli C, Saurin JC, et al. Scoring systems in clinical small-bowel capsule endoscopy: all you need to know! Endosc Int Open. 2021;9(6):E802-E23. 167. Sealock RJ, Thrift AP, El-Serag HB, Sellin J. Long-term follow up of patients with obscure gastrointestinal bleeding examined with video capsule endoscopy. Medicine (Baltimore). 2018;97(29):e11429. 168. Olano C, Pazos X, Avendaño K, Calleri A, Ketzoian C. Diagnostic yield and predictive factors of findings in small-bowel capsule endoscopy in the setting of iron-deficiency anemia. Endosc Int Open. 2018;6(6):E688-E93. 169. Yung DE, Vijayan S, Avni T, Douglas S, Kopylov U, Koulaouzidis A. Fecal occult blood testing for the prediction of small-bowel pathology detected by capsule endoscopy: a systematic review and meta-analysis. Ann Gastroenterol. 2017;30(2):186-91. 170. Endo H, Kato T, Sakai E, Taniguchi L, Arimoto J, Kawamura H, et al. Is a fecal occult blood test a useful tool for judging whether to perform capsule endoscopy in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy? J Gastroenterol. 2017;52(2):194-202. 171. Efthymiou M, Allen PB, Jayasekera C, Taylor PV, Taylor AC. Value of fecal occult blood test as a screening test before capsule endoscopy. Eur J Gastroenterol Hepatol. 2011;23(8):690-4. 172. Kobayashi Y, Watabe H, Yamada A, Suzuki H, Hirata Y, Yamaji Y, et al. Impact of fecal occult blood on obscure gastrointestinal bleeding: observational study. World J Gastroenterol. 2015;21(1):326-32. 173. Levi Z, Gal E, Vilkin A, Chonen Y, Belfer RG, Fraser G, et al. Fecal immunochemical test and small bowel lesions detected on capsule endoscopy: results of a prospective study in patients with obscure occult gastrointestinal bleeding. Eur J Gastroenterol Hepatol. 2011;23(11):1024-8. 174. Judge C, Tighe D, Barry L, O'Neill J, Wong J, Shahin A, et al. Predicting pathology on small bowel capsule endoscopy: a good FIT. Endosc Int Open. 2019;7(11):E1379-E85. 175. Katsinelos P, Chatzimavroudis G, Terzoudis S, Patsis I, Fasoulas K, Katsinelos T, et al. Diagnostic yield and clinical impact of capsule endoscopy in obscure gastrointestinal 117 Page 118 of 129 bleeding during routine clinical practice: a single-center experience. Med Princ Pract. 2011;20(1):60-5. 176. Ko CW, Siddique SM, Patel A, Harris A, Sultan S, Altayar O, et al. AGA Clinical Practice Guidelines on the Gastrointestinal Evaluation of Iron Deficiency Anemia. Gastroenterology. 2020;159(3):1085-94. 177. Gerson LB, Fidler JL, Cave DR, Leighton JA. ACG Clinical Guideline: Diagnosis and Management of Small Bowel Bleeding. Am J Gastroenterol. 2015;110(9):1265-87; quiz 88. 178. Dickey S, Rockey DC. The Natural History of Iron Deficiency Anemia. Am J Med Sci. 2019;358(5):357-62. 179. Liao Z, Gao R, Xu C, Li Z-S. Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. Gastrointestinal endoscopy. 2010;71(2):280-6. 180. Wang X, Hu X, Xu Y, Yong J, Li X, Zhang K, et al. A systematic review on diagnosis and treatment of gastrointestinal diseases by magnetically controlled capsule endoscopy and artificial intelligence. Therapeutic Advances in Gastroenterology. 2023;16. 181. Gao Y, Cai MX, Tian B, Lin H, Jiang ZY, Yang XC, et al. Setting 6-Minute Minimal Examination Time Improves the Detection of Focal Upper Gastrointestinal Tract Lesions During Endoscopy: A Multicenter Prospective Study. Clin Transl Gastroenterol. 2023;14(8):e00612. 182. Jiang X, Pan J, Xu Q, Song YH, Sun HH, Peng C, et al. Diagnostic accuracy of magnetically guided capsule endoscopy with a detachable string for detecting oesophagogastric varices in adults with cirrhosis: prospective multicentre study. BMJ. 2024;384:e078581."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["M.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/36770/1/Thesis%20with%20corrections240425.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Iron deficiency anaemia (IDA) is a common clinical problem in the adult population. The prevalence of pan enteric pathology in IDA is unknown. Oesophagogastroduodenoscopy (OGD) is the gold standard examination, but it can be poorly tolerated and often requires the use of sedation. Meanwhile capsule endoscopy allows us to image the upper gastrointestinal tract (GI) and the small bowel in one sitting and it is well tolerated. The demand for capsule endoscopy is increasing, but evaluation capsule endoscopy videos is time consuming and requires the readers ongoing attention. Preliminary data has shown that the use of artificial intelligence (AI) in capsule endoscopy can significantly reduce reading times. With the growing demand for capsule endoscopy there is a need for biomarkers which can help risk stratify capsule endoscopy referrals. This thesis examines the role of capsule endoscopy in patients with IDA and also evaluated the role of faecal immunochemical test (FIT) for risk stratifying patients for small bowel capsule endoscopy. As part of this thesis, a multicentre prospective study of 170 patients was carried out which investigated the prevalence of pan enteric pathology in patients with IDA. The diagnostic yield of lesions responsible for blood loss on OGD, capsule endoscopy and colonoscopy were 27.6%, 49.4% and 20% respectively (p <0.0001). We also compared the use of magnetically controlled capsule endoscopy (MACE) with OGD in the assessment of the upper gastrointestinal tract prospectively in 158 patients with IDA. This study showed that MACE identified significantly more lesions compared with OGD in the upper GI tract 119 vs 57 (95% CI 0.0- 0.08; P <0.001). No adverse events were recorded and there was no capsule retention. In the setting of IDA and the small bowel, a multicentre prospective study of 128 patients evaluated the role of AI- assisted reading in small bowel (SB) capsule endoscopy. In this study AI- assisted SB reading significantly reduced the reading time [ mean standard read 18.13 min (SD 8.34) vs AI assisted SB reading time 2.27 (SD 2.05) (p<0.0001)]. The per patient diagnostic yield between standard read and AI assisted read was non-inferior [48.4%, 95%CI (40.0- 57.0) vs 53.9%, 95%CI (45.3- 62.3)]. The role of FIT in the detection of small bowel pathology is yet to be defined. In this single centre prospective study the role of FIT in predicting small bowel pathology in 79 patients with IDA was evaluated. We did not find that FIT conferred any additional benefit in the detection of small bowel pathology in patients with IDA, however the diagnostic yield of small bowel capsule endoscopy in patients with IDA is high at 40.2%. In conclusions this thesis supports the use of MACE in the evaluation of the upper GI tract and small bowel in patients with first presentation and /or refractory IDA. It also supports the role of artificial intelligence in SB capsule endoscopy. There is a pressing need for biomarkers to help triage SB capsule endoscopy referrals, however FIT is not a reliable biomarker for the presence of SB pathology in patients with IDA."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Pathology in the gastrointestinal tract causing anaemia- lesion location and the role of capsule endoscopy."]}]}],"canonical_facts":{"dc:contributor.advisor":["Sidhu, Reena","Mark, McAlindon","Imran, Aziz"],"dc:creator":["Oka, Priya"],"dc:date":["2024-12"],"dc:date.issued":["2024-12"],"dc:description.abstract":["Iron deficiency anaemia (IDA) is a common clinical problem in the adult population. The prevalence of pan enteric pathology in IDA is unknown. Oesophagogastroduodenoscopy (OGD) is the gold standard examination, but it can be poorly tolerated and often requires the use of sedation. Meanwhile capsule endoscopy allows us to image the upper gastrointestinal tract (GI) and the small bowel in one sitting and it is well tolerated. The demand for capsule endoscopy is increasing, but evaluation capsule endoscopy videos is time consuming and requires the readers ongoing attention. Preliminary data has shown that the use of artificial intelligence (AI) in capsule endoscopy can significantly reduce reading times. With the growing demand for capsule endoscopy there is a need for biomarkers which can help risk stratify capsule endoscopy referrals. This thesis examines the role of capsule endoscopy in patients with IDA and also evaluated the role of faecal immunochemical test (FIT) for risk stratifying patients for small bowel capsule endoscopy. As part of this thesis, a multicentre prospective study of 170 patients was carried out which investigated the prevalence of pan enteric pathology in patients with IDA. The diagnostic yield of lesions responsible for blood loss on OGD, capsule endoscopy and colonoscopy were 27.6%, 49.4% and 20% respectively (p <0.0001). We also compared the use of magnetically controlled capsule endoscopy (MACE) with OGD in the assessment of the upper gastrointestinal tract prospectively in 158 patients with IDA. This study showed that MACE identified significantly more lesions compared with OGD in the upper GI tract 119 vs 57 (95% CI 0.0- 0.08; P <0.001). No adverse events were recorded and there was no capsule retention. In the setting of IDA and the small bowel, a multicentre prospective study of 128 patients evaluated the role of AI- assisted reading in small bowel (SB) capsule endoscopy. In this study AI- assisted SB reading significantly reduced the reading time [ mean standard read 18.13 min (SD 8.34) vs AI assisted SB reading time 2.27 (SD 2.05) (p<0.0001)]. The per patient diagnostic yield between standard read and AI assisted read was non-inferior [48.4%, 95%CI (40.0- 57.0) vs 53.9%, 95%CI (45.3- 62.3)]. The role of FIT in the detection of small bowel pathology is yet to be defined. In this single centre prospective study the role of FIT in predicting small bowel pathology in 79 patients with IDA was evaluated. We did not find that FIT conferred any additional benefit in the detection of small bowel pathology in patients with IDA, however the diagnostic yield of small bowel capsule endoscopy in patients with IDA is high at 40.2%. In conclusions this thesis supports the use of MACE in the evaluation of the upper GI tract and small bowel in patients with first presentation and /or refractory IDA. It also supports the role of artificial intelligence in SB capsule endoscopy. There is a pressing need for biomarkers to help triage SB capsule endoscopy referrals, however FIT is not a reliable biomarker for the presence of SB pathology in patients with IDA."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/36770/1/Thesis%20with%20corrections240425.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Medicine (Sheffield)","Division of Clinical Medicine, School of Medicine and Population Health"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/36770/"],"dc:relation.references":["1. Goddard AF, James MW, McIntyre AS, Scott BB, Gastroenterology BSo. Guidelines for the management of iron deficiency anaemia. Gut. 2011;60(10):1309-16. 2. Kepczyk T, Kadakia SC. Prospective evaluation of gastrointestinal tract in patients with iron-deficiency anemia. Dig Dis Sci. 1995;40(6):1283-9. 3. Rockey DC, Cello JP. Evaluation of the gastrointestinal tract in patients with iron deficiency anemia. N Engl J Med. 1993;329(23):1691-5. 4. Hardwick RH, Armstrong CP. Synchronous upper and lower gastrointestinal endoscopy is an effective method of investigating iron-deficiency anaemia. Br J Surg. 1997;84(12):1725-8. 5. Niv E, Elis A, Zissin R, Naftali T, Novis B, Lishner M. Iron deficiency anemia in patients without gastrointestinal symptoms--a prospective study. Fam Pract. 2005;22(1):58-61. 6. Wilcox CM, Alexander LN, Clark WS. Prospective evaluation of the gastrointestinal tract in patients with iron deficiency and no systemic or gastrointestinal symptoms or signs. Am J Med. 1997;103(5):405-9. 7. Ching H-L, Phillips V, Healy A, Sidhu R, McAlindon M. PTH-022 A Novel Experience of The Pillcam® ESO 3 Capsule Endoscope In Patients Unwilling To Undergo Conventional Upper GI Endoscopy. Gut. 2016;65(Suppl 1):A228-A. 8. de Franchis R, Eisen GM, Laine L, Fernandez-Urien I, Herrerias JM, Brown RD, et al. Esophageal capsule endoscopy for screening and surveillance of esophageal varices in patients with portal hypertension. Hepatology. 2008;47(5):1595-603. 9. Gutkin E, Shalomov A, Hussain SA, Kim SH, Cortes R, Gray S, et al. Pillcam ESO(®) is more accurate than clinical scoring systems in risk stratifying emergency room patients with acute upper gastrointestinal bleeding. Therap Adv Gastroenterol. 2013;6(3):193-8. 10. Liao Z, Hou X, Lin-Hu EQ, Sheng JQ, Ge ZZ, Jiang B, et al. Accuracy of Magnetically Controlled Capsule Endoscopy, Compared With Conventional Gastroscopy, in Detection of Gastric Diseases. Clin Gastroenterol Hepatol. 2016;14(9):1266-73.e1. 11. Irvine AJ, Sanders DS, Hopper A, Kurien M, Sidhu R. How does tolerability of double balloon enteroscopy compare to other forms of endoscopy? Frontline Gastroenterol. 2016;7(1):41-6. 12. Nemeth A, Wurm Johansson G, Nielsen J, Thorlacius H, Toth E. Capsule retention related to small bowel capsule endoscopy: a large European single-center 10-year clinical experience. United European Gastroenterol J. 2017;5(5):677-86. 13. 14. Lewis BS. Small intestinal bleeding. Gastroenterol Clin North Am. 1994;23(1):67-91. Triester SL, Leighton JA, Leontiadis GI, Fleischer DE, Hara AK, Heigh RI, et al. A meta analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with obscure gastrointestinal bleeding. Am J Gastroenterol. 2005;100(11):2407-18. 15. Koulaouzidis A, Rondonotti E, Giannakou A, Plevris JN. Diagnostic yield of small bowel capsule endoscopy in patients with iron-deficiency anemia: a systematic review. Gastrointest Endosc. 2012;76(5):983-92. 107 16. Page 108 of 129 Li XL, Shen JT, Li YP, Tang CW, Huang LB, Li CC, et al. Capsule endoscopy in diagnosis of small bowel diseases: a health technology assessment. J Evid Based Med. 2014;7(2):84 102. 17. Yung DE, Rondonotti E, Giannakou A, Avni T, Rosa B, Toth E, et al. Capsule endoscopy in young patients with iron deficiency anaemia and negative bidirectional gastrointestinal endoscopy. United European Gastroenterol J. 2017;5(7):974-81. 18. Hale MF, Rahman I, Drew K, Sidhu R, Riley SA, Patel P, et al. Magnetically steerable gastric capsule endoscopy is equivalent to flexible endoscopy in the detection of markers in an excised porcine stomach model: results of a randomized trial. Endoscopy. 2015;47(7):650-3. 19. Hale MF, Drew K, Sidhu R, McAlindon ME. Does magnetically assisted capsule endoscopy improve small bowel capsule endoscopy completion rate? A randomised controlled trial. Endosc Int Open. 2016;4(2):E215-21. 20. Saurin J-C, Lapalus MG, Cholet F, D’Halluin PN, Filoche B, Gaudric M, et al. Can we shorten the small-bowel capsule reading time with the “Quick-view” image detection system? Digestive and liver disease. 2012;44(6):477-81. 21. Westerhof J, Koornstra JJ, Weersma RK. Can we reduce capsule endoscopy reading times? Gastrointestinal endoscopy. 2009;69(3):497-502. 22. Hosoe N, Rey J-F, Imaeda H, Bessho R, Ichikawa R, Ida Y, et al. Evaluations of capsule endoscopy software in reducing the reading time and the rate of false negatives by inexperienced endoscopists. Clinics and research in hepatology and gastroenterology. 2012;36(1):66-71. 23. Leenhardt R, Vasseur P, Li C, Saurin JC, Rahmi G, Cholet F, et al. A neural network algorithm for detection of GI angiectasia during small-bowel capsule endoscopy. Gastrointestinal endoscopy. 2019;89(1):189-94. 24. Ding Z, Shi H, Zhang H, Meng L, Fan M, Han C, et al. Gastroenterologist-Level Identification of Small-Bowel Diseases and Normal Variants by Capsule Endoscopy Using a Deep-Learning Model. Gastroenterology. 2019;157(4):1044-54.e5. 25. Spada C, Piccirelli S, Hassan C, Ferrari C, Toth E, González-Suárez B, et al. AI-assisted capsule endoscopy reading in suspected small bowel bleeding: a multicentre prospective study. The Lancet Digital Health. 2024;6(5):e345-e53. 26. Young GP, Symonds EL, Allison JE, Cole SR, Fraser CG, Halloran SP, et al. Advances in Fecal Occult Blood Tests: the FIT revolution. Dig Dis Sci. 2015;60(3):609-22. 27. Grobbee EJ, Wisse PHA, Schreuders EH, van Roon A, van Dam L, Zauber AG, et al. Guaiac-based faecal occult blood tests versus faecal immunochemical tests for colorectal cancer screening in average-risk individuals. Cochrane Database Syst Rev. 2022;6(6):CD009276. 28. Brenner H, Tao S. Superior diagnostic performance of faecal immunochemical tests for haemoglobin in a head-to-head comparison with guaiac based faecal occult blood test among 2235 participants of screening colonoscopy. Eur J Cancer. 2013;49(14):3049-54. 29. Kuipers EJ, Rösch T, Bretthauer M. Colorectal cancer screening--optimizing current strategies and new directions. Nat Rev Clin Oncol. 2013;10(3):130-42. 30. Schreuders EH, Ruco A, Rabeneck L, Schoen RE, Sung JJ, Young GP, et al. Colorectal cancer screening: a global overview of existing programmes. Gut. 2015;64(10):1637-49. 31. Nieuwenburg SAV, Vuik FER, Kruip MJHA, Kuipers EJ, Spaander MCW. Effect of anticoagulants and NSAIDs on accuracy of faecal immunochemical tests (FITs) in colorectal cancer screening: a systematic review and meta-analysis. Gut. 2019;68(5):866-72. 108 32. Page 109 of 129 Allison JE, Fraser CG, Halloran SP, Young GP. Population screening for colorectal cancer means getting FIT: the past, present, and future of colorectal cancer screening using the fecal immunochemical test for hemoglobin (FIT). Gut Liver. 2014;8(2):117-30. 33. Cole SR, Young GP, Esterman A, Cadd B, Morcom J. A Randomised Trial of the Impact of New Faecal Haemoglobin Test Technologies on Population Participation in Screening for Colorectal Cancer. Journal of Medical Screening. 2003;10(3):117-22. 34. Chapman C, Bunce J, Oliver S, Ng O, Tangri A, Rogers R, et al. Service evaluation of faecal immunochemical testing and anaemia for risk stratification in the 2-week-wait pathway for colorectal cancer. BJS Open. 2019;3(3):395-402. 35. Monahan KJ, Davies MM, Abulafi M, Banerjea A, Nicholson BD, Arasaradnam R, et al. Faecal immunochemical testing (FIT) in patients with signs or symptoms of suspected colorectal cancer (CRC): a joint guideline from the Association of Coloproctology of Great Britain and Ireland (ACPGBI) and the British Society of Gastroenterology (BSG). Gut. 2022;71(10):1939-62. 36. Park JJ, Cheon JH. Small bowel evaluation in asymptomatic fecal immunochemical test-positive patients with a negative colonoscopy: is it necessary? Dig Dis Sci. 2011;56(10):2773-5. 37. Levi Z, Rozen P, Hazazi R, Vilkin A, Waked A, Maoz E, et al. A quantitative immunochemical fecal occult blood test for colorectal neoplasia. Ann Intern Med. 2007;146(4):244-55. 38. Park DI, Ryu S, Kim YH, Lee SH, Lee CK, Eun CS, et al. Comparison of guaiac-based and quantitative immunochemical fecal occult blood testing in a population at average risk undergoing colorectal cancer screening. Am J Gastroenterol. 2010;105(9):2017-25. 39. McQuaid KR, Laine L. A systematic review and meta-analysis of randomized, controlled trials of moderate sedation for routine endoscopic procedures. Gastrointest Endosc. 2008;67(6):910-23. 40. Crooks CJ, Card TR, West J. The risk of unexpected hospital admissions and primary care visits after an elective day-case gastroscopy: A cohort study within England. Aliment Pharmacol Ther. 2022. 41. Ravindran S, Bassett P, Shaw T, Dron M, Broughton R, Johnston D, et al. National census of UK endoscopy services in 2019. Frontline Gastroenterol. 2021;12(6):451-60. 42. Ford AC, Marwaha A, Lim A, Moayyedi P. What is the prevalence of clinically significant endoscopic findings in subjects with dyspepsia? Systematic review and meta analysis. Clin Gastroenterol Hepatol. 2010;8(10):830-7, 7.e1-2. 43. Tai FWD, Wray N, Sidhu R, Hopper A, McAlindon M. Factors associated with oesophagogastric cancers missed by gastroscopy: a case-control study. Frontline Gastroenterol. 2020;11(3):194-201. 44. Moayyedi P, Tepper J, Hilsden R, Rabeneck L. International comparisons of manpower in gastroenterology. Am J Gastroenterol. 2007;102(3):478-81. 45. Hori S, Tsuda K, Murayama S, Matsushita M, Yukawa K, Kozuka T. CT of gastric carcinoma: preliminary results with a new scanning technique. Radiographics. 1992;12(2):257-68. 46. Minami M, Kawauchi N, Itai Y, Niki T, Sasaki Y. Gastric tumors: radiologic-pathologic correlation and accuracy of T staging with dynamic CT. Radiology. 1992;185(1):173-8. 47. Low VH, Levine MS, Rubesin SE, Laufer I, Herlinger H. Diagnosis of gastric carcinoma: sensitivity of double-contrast barium studies. AJR Am J Roentgenol. 1994;162(2):329-34. 109 48. Page 110 of 129 Levine MS, Chu P, Furth EE, Rubesin SE, Laufer I, Herlinger H. Carcinoma of the esophagus and esophagogastric junction: sensitivity of radiographic diagnosis. AJR Am J Roentgenol. 1997;168(6):1423-6. 49. Khanderia E, Markar SR, Acharya A, Kim Y, Kim YW, Hanna GB. The Influence of Gastric Cancer Screening on the Stage at Diagnosis and Survival: A Meta-Analysis of Comparative Studies in the Far East. J Clin Gastroenterol. 2016;50(3):190-7. 50. Kim JW, Shin SS, Heo SH, Lim HS, Lim NY, Park YK, et al. The role of three dimensional multidetector CT gastrography in the preoperative imaging of stomach cancer: emphasis on detection and localization of the tumor. Korean J Radiol. 2015;16(1):80-9. 51. Kim JH, Park SH, Hong HS, Auh YH. CT gastrography. Abdom Imaging. 2005;30(5):509-17. 52. Bouchard S, Ibrahim M, Van Gossum A. Video capsule endoscopy: perspectives of a revolutionary technique. World J Gastroenterol. 2014;20(46):17330-44. 53. Ching HL, Healy A, Thurston V, Hale MF, Sidhu R, McAlindon ME. Upper gastrointestinal tract capsule endoscopy using a nurse-led protocol: First reported experience. World J Gastroenterol. 2018;24(26):2893-901. 54. Park J, Cho YK, Kim JH. Current and Future Use of Esophageal Capsule Endoscopy. Clin Endosc. 2018;51(4):317-22. 55. Bhardwaj A, Hollenbeak CS, Pooran N, Mathew A. A meta-analysis of the diagnostic accuracy of esophageal capsule endoscopy for Barrett's esophagus in patients with gastroesophageal reflux disease. Am J Gastroenterol. 2009;104(6):1533-9. 56. Liu L, Towfighian S, Hila A. A Review of Locomotion Systems for Capsule Endoscopy. IEEE Rev Biomed Eng. 2015;8:138-51. 57. Koulaouzidis A, Iakovidis DK, Karargyris A, Rondonotti E. Wireless endoscopy in 2020: Will it still be a capsule? World J Gastroenterol. 2015;21(17):5119-30. 58. Carpi F, Galbiati S, Carpi A. Magnetic shells for gastrointestinal endoscopic capsules as a means to control their motion. Biomed Pharmacother. 2006;60(8):370-4. 59. Ching HL, Hale MF, Sidhu R, Beg S, Ragunath K, McAlindon ME. Magnetically assisted capsule endoscopy in suspected acute upper GI bleeding versus esophagogastroduodenoscopy in detecting focal lesions. Gastrointest Endosc. 2019;90(3):430-9. 60. Rahman I, Pioche M, Shim CS, Lee SP, Sung IK, Saurin JC, et al. Magnetic-assisted capsule endoscopy in the upper GI tract by using a novel navigation system (with video). Gastrointest Endosc. 2016;83(5):889-95.e1. 61. Ching HL, Hale MF, Kurien M, Campbell JA, Chetcuti Zammit S, Healy A, et al. Diagnostic yield of magnetically assisted capsule endoscopy versus gastroscopy in recurrent and refractory iron deficiency anemia. Endoscopy. 2019;51(5):409-18. 62. Denzer UW, Rösch T, Hoytat B, Abdel-Hamid M, Hebuterne X, Vanbiervielt G, et al. Magnetically guided capsule versus conventional gastroscopy for upper abdominal complaints: a prospective blinded study. J Clin Gastroenterol. 2015;49(2):101-7. 63. Qian YY, Zhu SG, Hou X, Zhou W, An W, Su XJ, et al. Preliminary study of magnetically controlled capsule gastroscopy for diagnosing superficial gastric neoplasia. Dig Liver Dis. 2018;50(10):1041-6. 64. Zhao AJ, Qian YY, Sun H, Hou X, Pan J, Liu X, et al. Screening for gastric cancer with magnetically controlled capsule gastroscopy in asymptomatic individuals. Gastrointest Endosc. 2018;88(3):466-74.e1. 110 65. Page 111 of 129 Ching HL, Hale MF, Sidhu R, McAlindon ME. Reassessing the value of gastroscopy for the investigation of dyspepsia. Frontline Gastroenterol. 2018;9(1):62-6. 66. Kelvin FM, Maglinte DD. Enteroclysis or small bowel follow-through in Crohn' s diseases? Gastroenterology. 1998;114(6):1349-51. 67. Panes J, Bouhnik Y, Reinisch W, Stoker J, Taylor SA, Baumgart DC, et al. Imaging techniques for assessment of inflammatory bowel disease: joint ECCO and ESGAR evidence based consensus guidelines. J Crohns Colitis. 2013;7(7):556-85. 68. Ahmed O, Rodrigues DM, Nguyen GC. Magnetic Resonance Imaging of the Small Bowel in Crohn's Disease: A Systematic Review and Meta-Analysis. Can J Gastroenterol Hepatol. 2016;2016:7857352. 69. Pennazio M, Spada C, Eliakim R, Keuchel M, May A, Mulder CJ, et al. Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline. Endoscopy. 2015;47(4):352-76. 70. Dolak W, Kulnigg-Dabsch S, Evstatiev R, Gasche C, Trauner M, Püspök A. A randomized head-to-head study of small-bowel imaging comparing MiroCam and EndoCapsule. Endoscopy. 2012;44(11):1012-20. 71. Hartmann D, Eickhoff A, Damian U, Riemann JF. Diagnosis of small-bowel pathology using paired capsule endoscopy with two different devices: a randomized study. Endoscopy. 2007;39(12):1041-5. 72. Cave DR, Fleischer DE, Leighton JA, Faigel DO, Heigh RI, Sharma VK, et al. A multicenter randomized comparison of the Endocapsule and the Pillcam SB. Gastrointest Endosc. 2008;68(3):487-94. 73. Pioche M, Gaudin JL, Filoche B, Jacob P, Lamouliatte H, Lapalus MG, et al. Prospective, randomized comparison of two small-bowel capsule endoscopy systems in patients with obscure GI bleeding. Gastrointest Endosc. 2011;73(6):1181-8. 74. Riccioni ME, Urgesi R, Spada C, Cianci R, Pelecca G, Bizzotto A, et al. Unexplained iron deficiency anaemia: Is it worthwhile to perform capsule endoscopy? Dig Liver Dis. 2010;42(8):560-6. 75. Milano A, Balatsinou C, Filippone A, Caldarella MP, Laterza F, Lapenna D, et al. A prospective evaluation of iron deficiency anemia in the GI endoscopy setting: role of standard endoscopy, videocapsule endoscopy, and CT-enteroclysis. Gastrointest Endosc. 2011;73(5):1002-8. 76. Liao Z, Gao R, Xu C, Li ZS. Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. Gastrointest Endosc. 2010;71(2):280-6. 77. Yung DE, Rondonotti E, Sykes C, Pennazio M, Plevris JN, Koulaouzidis A. Systematic review and meta-analysis: is bowel preparation still necessary in small bowel capsule endoscopy? Expert Rev Gastroenterol Hepatol. 2017;11(10):979-93. 78. Rokkas T, Papaxoinis K, Triantafyllou K, Pistiolas D, Ladas SD. Does purgative preparation influence the diagnostic yield of small bowel video capsule endoscopy?: A meta-analysis. Am J Gastroenterol. 2009;104(1):219-27. 79. Katsinelos P, Fasoylas K, Chatzimavroudis G, Lazaraki G, Zavos C, Pilpilidis I, et al. Diagnostic yield and clinical management after capsule endoscopy in daily clinical practice: A single-center experience. Hippokratia. 2010;14(4):271-6. 111 80. Page 112 of 129 Ramirez FC, Shaukat MS, Young MA, Johnson DA, Akins R. Feasibility and safety of string, wireless capsule endoscopy in the diagnosis of Barrett's esophagus. Gastrointest Endosc. 2005;61(6):741-6. 81. Singh A, Marshall C, Chaudhuri B, Okoli C, Foley A, Person SD, et al. Timing of video capsule endoscopy relative to overt obscure GI bleeding: implications from a retrospective study. Gastrointest Endosc. 2013;77(5):761-6. 82. Rondonotti E, Soncini M, Girelli C, Ballardini G, Bianchi G, Brunati S, et al. Small bowel capsule endoscopy in clinical practice: a multicenter 7-year survey. Eur J Gastroenterol Hepatol. 2010;22(11):1380-6. 83. Cheung DY, Kim JS, Shim KN, Choi MG, Group KGIS. The Usefulness of Capsule Endoscopy for Small Bowel Tumors. Clin Endosc. 2016;49(1):21-5. 84. Pasha SF, Pennazio M, Rondonotti E, Wolf D, Buras MR, Albert JG, et al. Capsule Retention in Crohn's Disease: A Meta-analysis. Inflamm Bowel Dis. 2020;26(1):33-42. 85. Caunedo-Alvarez A, Romero-Vazquez J, Herrerias-Gutierrez JM. Patency and Agile capsules. World J Gastroenterol. 2008;14(34):5269-73. 86. Rozendorn N, Klang E, Lahat A, Yablecovitch D, Kopylov U, Eliakim A, et al. Prediction of patency capsule retention in known Crohn's disease patients by using magnetic resonance imaging. Gastrointest Endosc. 2016;83(1):182-7. 87. Zagorowicz ES, Pietrzak AM, Wronska E, Pachlewski J, Rutkowski P, Kraszewska E, et al. Small bowel tumors detected and missed during capsule endoscopy: single center experience. World J Gastroenterol. 2013;19(47):9043-8. 88. Kim TJ, Kim ER, Chang DK, Kim YH, Hong SN. Comparison of the Efficacy and Safety of Single- versus Double-Balloon Enteroscopy Performed by Endoscopist Experts in Single Balloon Enteroscopy: A Single-Center Experience and Meta-Analysis. Gut Liver. 2017;11(4):520-7. 89. Cooper GS, Kou TD, Rex DK. Complications following colonoscopy with anesthesia assistance: a population-based analysis. JAMA Intern Med. 2013;173(7):551-6. 90. Wang P, Xu T, Ngamruengphong S, Makary MA, Kalloo A, Hutfless S. Rates of infection after colonoscopy and osophagogastroduodenoscopy in ambulatory surgery centres in the USA. Gut. 2018;67(9):1626-36. 91. Zhao S, Wang S, Pan P, Xia T, Chang X, Yang X, et al. Magnitude, Risk Factors, and Factors Associated With Adenoma Miss Rate of Tandem Colonoscopy: A Systematic Review and Meta-analysis. Gastroenterology. 2019;156(6):1661-74.e11. 92. Moss S, Mathews C, Day TJ, Smith S, Seaman HE, Snowball J, et al. Increased uptake and improved outcomes of bowel cancer screening with a faecal immunochemical test: results from a pilot study within the national screening programme in England. Gut. 2017;66(9):1631-44. 93. Palmer CK, Thomas MC, von Wagner C, Raine R. Reasons for non-uptake and subsequent participation in the NHS Bowel Cancer Screening Programme: a qualitative study. Br J Cancer. 2014;110(7):1705-11. 94. Al-Najami I, Rancinger CP, Larsen MK, Spolén E, Baatrup G. The Diagnostic Yield of Colonoscopy Stratified by Indications. Gastroenterol Res Pract. 2017;2017:4910143. 95. Gavin DR, Valori RM, Anderson JT, Donnelly MT, Williams JG, Swarbrick ET. The national colonoscopy audit: a nationwide assessment of the quality and safety of colonoscopy in the UK. Gut. 2013;62(2):242-9. 112 96. Page 113 of 129 Deding U, Kaalby L, Bøggild H, Plantener E, Wollesen MK, Kobaek-Larsen M, et al. Colon Capsule Endoscopy vs. CT Colonography Following Incomplete Colonoscopy: A Systematic Review with Meta-Analysis. Cancers (Basel). 2020;12(11). 97. Pickhardt PJ, Correale L, Morra L, Regge D, Hassan C. JOURNAL CLUB: Extracolonic Findings at CT Colonography: Systematic Review and Meta-Analysis. AJR Am J Roentgenol. 2018;211(1):25-39. 98. Spada C, Hassan C, Bellini D, Burling D, Cappello G, Carretero C, et al. Imaging alternatives to colonoscopy: CT colonography and colon capsule. European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastrointestinal and Abdominal Radiology (ESGAR) Guideline - Update 2020. Eur Radiol. 2021;31(5):2967-82. 99. Vuik FER, Nieuwenburg SAV, Moen S, Spada C, Senore C, Hassan C, et al. Colon capsule endoscopy in colorectal cancer screening: a systematic review. Endoscopy. 2021;53(8):815-24. 100. Möllers T, Schwab M, Gildein L, Hoffmeister M, Albert J, Brenner H, et al. Second generation colon capsule endoscopy for detection of colorectal polyps: Systematic review and meta-analysis of clinical trials. Endosc Int Open. 2021;9(4):E562-E71. 101. Spada C, Barbaro F, Andrisani G, Minelli Grazioli L, Hassan C, Costamagna I, et al. Colon capsule endoscopy: What we know and what we would like to know. World J Gastroenterol. 2014;20(45):16948-55. 102. Ismail MS, Murphy G, Semenov S, McNamara D. Comparing Colon Capsule Endoscopy to colonoscopy; a symptomatic patient's perspective. BMC Gastroenterol. 2022;22(1):31. 103. Spada C, Hassan C, Galmiche JP, Neuhaus H, Dumonceau JM, Adler S, et al. Colon capsule endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline. Endoscopy. 2012;44(5):527-36. 104. Baltes P, Bota M, Albert J, Philipper M, Hörster HG, Hagenmüller F, et al. PillCamColon2 after incomplete colonoscopy - A prospective multicenter study. World J Gastroenterol. 2018;24(31):3556-66. 105. NHS. Clinical guide for using colon capsule endoscopy in the lower gastrointestinal pathway. https://www.nice.org.uk/Media/Default/About/COVID-19/Specialty guides/triaging-patients-with-lower-gi-symptoms.pdf (access March 31, 2021).November 2020. [ 106. MacLeod C, Hudson J, Brogan M, Cotton S, Treweek S, MacLennan G, et al. ScotCap - A large observational cohort study. Colorectal Dis. 2022;24(4):411-21. 107. Deding U, Kaalby L, Baatrup G, Kobaek-Larsen M, Thygesen MK, Epstein O, et al. The Effect of Prucalopride on the Completion Rate and Polyp Detection Rate of Colon Capsule Endoscopies. Clin Epidemiol. 2022;14:437-44. 108. Bruining DH, Oliva S, Fleisher MR, Fischer M, Fletcher JG, group Bs. Panenteric capsule endoscopy versus ileocolonoscopy plus magnetic resonance enterography in Crohn's disease: a multicentre, prospective study. BMJ Open Gastroenterol. 2020;7(1). 109. Cosnes J, Gower-Rousseau C, Seksik P, Cortot A. Epidemiology and natural history of inflammatory bowel diseases. Gastroenterology. 2011;140(6):1785-94. 110. Yamamoto T, Watanabe T. Surgery for luminal Crohn's disease. World J Gastroenterol. 2014;20(1):78-90. 111. Meister T, Heinzow HS, Domagk D, Dortgolz A, Lenze F, Ross M, et al. Colon capsule endoscopy versus standard colonoscopy in assessing disease activity of ulcerative colitis: a prospective trial. Tech Coloproctol. 2013;17(6):641-6. 113 Page 114 of 129 112. Sung J, Ho KY, Chiu HM, Ching J, Travis S, Peled R. The use of Pillcam Colon in assessing mucosal inflammation in ulcerative colitis: a multicenter study. Endoscopy. 2012;44(8):754-8. 113. Mehdizadeh S, Chen GC, Barkodar L, Enayati PJ, Pirouz S, Yadegari M, et al. Capsule endoscopy in patients with Crohn's disease: diagnostic yield and safety. Gastrointest Endosc. 2010;71(1):121-7. 114. Eliakim R, Spada C, Lapidus A, Eyal I, Pecere S, Fernández-Urién I, et al. Evaluation of a new pan-enteric video capsule endoscopy system in patients with suspected or established inflammatory bowel disease - feasibility study. Endosc Int Open. 2018;6(10):E1235-E46. 115. Snook J, Bhala N, Beales ILP, Cannings D, Kightley C, Logan RP, et al. British Society of Gastroenterology guidelines for the management of iron deficiency anaemia in adults. Gut. 2021;70(11):2030-51. 116. Landy J, Macfarlane B. Synchronous bidirectional endoscopy for iron deficiency anaemia: is it appropriate for patients under 50? Postgraduate Medical Journal. 2010;86(1016):338-40. 117. Urquhart J, Eisen G, Faigel DO, Mattek N, Holub J, Lieberman DA. A closer look at same-day bidirectional endoscopy. Gastrointestinal Endoscopy. 2009;69(2):271-7. 118. Stone H, Almilaji O, John C, Smith C, Surgenor SL, Ayres L, et al. The dedicated iron deficiency anaemia clinic: a 15-year experience. Frontline Gastroenterol. 2022;13(1):20-4. 119. McIntyre AS, Long RG. Prospective survey of investigations in outpatients referred with iron deficiency anaemia. Gut. 1993;34(8):1102-7. 120. Pengelly S, Fabricius M, McMenamin D, Wu E, Metzner M, Lewis SJ, et al. Attendance at iron deficiency anaemia clinic: audit of outcomes 5 years on. Colorectal Dis. 2013;15(4):423-7. 121. Cappellini MD, Motta I. Anemia in Clinical Practice-Definition and Classification: Does Hemoglobin Change With Aging? Semin Hematol. 2015;52(4):261-9. 122. Saurin JC, Delvaux M, Gaudin JL, Fassler I, Villarejo J, Vahedi K, et al. Diagnostic value of endoscopic capsule in patients with obscure digestive bleeding: blinded comparison with video push-enteroscopy. Endoscopy. 2003;35(7):576-84. 123. Annibale B, Capurso G, Chistolini A, D’Ambra G, DiGiulio E, Monarca B, et al. Gastrointestinal causes of refractory iron deficiency anemia in patients without gastrointestinal symptoms. The American journal of medicine. 2001;111(6):439-45. 124. Majid S, Salih M, Wasaya R, Jafri W. Predictors of gastrointestinal lesions on endoscopy in iron deficiency anemia without gastrointestinal symptoms. BMC Gastroenterology. 2008;8(1):52. 125. Yates JM, Logan ECM, Stewart RM. Iron deficiency anaemia in general practice: clinical outcomes over three years and factors influencing diagnostic investigations. Postgraduate Medical Journal. 2004;80(945):405-10. 126. Johnston C, Yung D, Joshi A, Plevris J, Koulaouzidis A. Small bowel malignancy in patients undergoing capsule endoscopy at a tertiary care academic center: Case series and review of the literature. Endoscopy International Open. 2017;05(06):E463-E70. 127. Sidhu PS, McAlindon ME, Drew K, Sidhu R. The Utility of Capsule Endoscopy in Patients under 50 Years of Age with Recurrent Iron Deficiency Anaemia: Is the Juice Worth the Squeeze? Gastroenterol Res Pract. 2015;2015:948574. 114 Page 115 of 129 128. Silva AC, Sheppard ZA, Surgenor SL, Williams EJ, Thomas PW, Snook JA. Clinical risk factors for underlying gastrointestinal malignancy in iron deficiency anaemia: the IDIOM study. Frontline Gastroenterology. 2014;5(4):237-42. 129. James MW, Chen CM, Goddard WP, Scott BB, Goddard AF. Risk factors for gastrointestinal malignancy in patients with iron-deficiency anaemia. Eur J Gastroenterol Hepatol. 2005;17(11):1197-203. 130. Kepczyk MT, Kadakia CSC. Prospective evaluation of gastrointestinal tract in patients with iron-deficiency anemia. Digestive Diseases and Sciences. 1995;40(6):1283-9. 131. Zaman A, Katon RM. Push enteroscopy for obscure gastrointestinal bleeding yields a high incidence of proximal lesions within reach of a standard endoscope. Gastrointest Endosc. 1998;47(5):372-6. 132. Descamps C, Schmit A, Van Gossum A. \"Missed\" upper gastrointestinal tract lesions may explain \"occult\" bleeding. Endoscopy. 1999;31(6):452-5. 133. Crooks CJ, Card TR, West J. The risk of unexpected hospital admissions and primary care visits after an elective day‐case gastroscopy: a cohort study within England. Alimentary Pharmacology & Therapeutics. 2022;56(1):56-66. 134. Campo R, Brullet E, Montserrat A, Calvet X, Moix J, Rué M, et al. Identification of factors that influence tolerance of upper gastrointestinal endoscopy. Eur J Gastroenterol Hepatol. 1999;11(2):201-4. 135. E. Mulcahy PK, M. R. Banks,, H. Factors Associated with Tolerance to, and Discomfort with, Unsedated Diagnostic Gastroscopy. Scandinavian Journal of Gastroenterology. 2001;36(12):1352-7. 136. Macleod C, Hudson J, Brogan M, Cotton S, Treweek S, Maclennan G, et al. ScotCap – A large observational cohort study. Colorectal Disease. 2022;24(4):411-21. 137. Rosa B, Andrade P, Lopes S, Gonçalves AR, Serrazina J, Marílio Cardoso P, et al. Pan Enteric Capsule Endoscopy: Current Applications and Future Perspectives. GE Port J Gastroenterol. 2024;31(2):89-100. 138. Liao Z, Duan XD, Xin L, Bo LM, Wang XH, Xiao GH, et al. Feasibility and safety of magnetic-controlled capsule endoscopy system in examination of human stomach: a pilot study in healthy volunteers. J Interv Gastroenterol. 2012;2(4):155-60. 139. Zou WB, Hou XH, Xin L, Liu J, Bo LM, Yu GY, et al. Magnetic-controlled capsule endoscopy vs. gastroscopy for gastric diseases: a two-center self-controlled comparative trial. Endoscopy. 2015;47(6):525-8. 140. Jiang B, Qian YY, Pan J, Jiang X, Wang YC, Zhu JH, et al. Second-generation magnetically controlled capsule gastroscopy with improved image resolution and frame rate: a randomized controlled clinical trial (with video). Gastrointest Endosc. 2020;91(6):1379-87. 141. Zhu SG, Qian YY, Tang XY, Zhu QQ, Zhou W, Du H, et al. Gastric preparation for magnetically controlled capsule endoscopy: A prospective, randomized single-blinded controlled trial. Dig Liver Dis. 2018;50(1):42-7. 142. Jiang X, Pan J, Li Z-S, Liao Z. Standardized examination procedure of magnetically controlled capsule endoscopy. VideoGIE. 2019;4(6):239-43. 143. Spencer HL, Lobo AJ, Riley SA. Variations in the reporting of endoscopies by different endoscopists. Clin Med (Lond). 2007;7(1):23-7. 144. Pimenta-Melo AR, Monteiro-Soares M, Libânio D, Dinis-Ribeiro M. Missing rate for gastric cancer during upper gastrointestinal endoscopy: a systematic review and meta analysis. European journal of gastroenterology & hepatology. 2016;28(9):1041-9. 115 Page 116 of 129 145. Teh JL, Tan JR, Lau LJ, Saxena N, Salim A, Tay A, et al. Longer examination time improves detection of gastric cancer during diagnostic upper gastrointestinal endoscopy. Clin Gastroenterol Hepatol. 2015;13(3):480-7.e2. 146. Park JM, Huo SM, Lee HH, Lee B-I, Song HJ, Choi M-G. Longer Observation Time Increases Proportion of Neoplasms Detected by Esophagogastroduodenoscopy. Gastroenterology. 2017;153(2):460-9.e1. 147. Tai FWD, Ching HL, Sloan M, Sidhu R, Mcalindon M. Comparison of patient tolerance and acceptability of magnet-controlled capsule endoscopy and flexible endoscopy in the investigation of dyspepsia. Endoscopy International Open. 2022;10(06):E735-E44. 148. Tai FWD, Healy A, Thokala P, Chetcuti Zammit S, Sidhu R, McAlindon M. Cost comparison of oral, transnasal and magnet assisted capsule endoscopy in the examination of the upper gastrointestinal tract in patients with dyspepsia. Frontline gastroenterology. 2022;14(4):300-5. 149. YF X, ZX W, He S Zhou YY ZY, He JL, Peng X, Yang ZX, Lv QJ, Yang H BJ, Fan CQ, Tang B, Hu CJ, Jie MM, Liu E, Lin H, Koulaouzidis A, XY Z. Fully automated magnetically controlled capsule endoscopy for examination of the stomach and small bowel: a prospective, feasibility, two-centre study.2021; 6(11):[914- 21 pp.]. 150. Meltzer AC, Kumar A, Kallus SJ, Schueler SA, Mattu N, Ma Y, et al. Magnetically controlled capsule for assessment of the gastric mucosa in symptomatic patients: a prospective, single-arm, single-center, comparative study. IGIE. 2023;2(2):139-47. 151. Wang S, Huang Y, Hu W, Mao H, McAlindon ME, Liu Y, et al. Detachable string magnetically controlled capsule endoscopy for detecting high-risk varices in compensated advanced chronic liver disease (CHESS1801): A prospective multicenter study. Lancet Reg Health West Pac. 2021;6:100072. 152. McAlindon ME. String used for oesophageal capsule endoscopy: help or hindrance? Eur J Gastroenterol Hepatol. 2024;36(12):1470-1. 153. Yu Y, Liao Z, Jiang X, Pan J, Zhou W, Lau JYW. The use of magnet‐controlled capsule endoscopy as the initial diagnostic tool in patients with acute upper gastrointestinal bleeding. Journal of Gastroenterology and Hepatology. 2023;38(11):2027-34. 154. Iddan G, Meron G, Glukhovsky A, Swain P. Wireless capsule endoscopy. Nature. 2000;405(6785):417. 155. Ebigbo A, Mendel R, Probst A, Manzeneder J, Souza Jr LAD, Papa JP, et al. Computer aided diagnosis using deep learning in the evaluation of early oesophageal adenocarcinoma. Gut. 2019;68(7):1143-5. 156. Hirasawa T, Aoyama K, Tanimoto T, Ishihara S, Shichijo S, Ozawa T, et al. Application of artificial intelligence using a convolutional neural network for detecting gastric cancer in endoscopic images. Gastric Cancer. 2018;21(4):653-60. 157. Beg S, Wronska E, Araujo I, González Suárez B, Ivanova E, Fedorov E, et al. Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy. Gastrointest Endosc. 2020;91(6):1322-7. 158. Piccirelli S, Mussetto A, Bellumat A, Cannizzaro R, Pennazio M, Pezzoli A, et al. New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times. Diagnostics. 2022;12(8):1783. 159. Tsuboi A, Oka S, Aoyama K, Saito H, Aoki T, Yamada A, et al. Artificial intelligence using a convolutional neural network for automatic detection of small‐bowel angioectasia in capsule endoscopy images. Digestive Endoscopy. 2020;32(3):382-90. 116 Page 117 of 129 160. Pennazio M, Rondonotti E, Despott EJ, Dray X, Keuchel M, Moreels T, et al. Small bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2022. Endoscopy. 2023;55(1):58-95. 161. Lai LH, Wong GL, Chow DK, Lau JY, Sung JJ, Leung WK. Inter-observer variations on interpretation of capsule endoscopies. Eur J Gastroenterol Hepatol. 2006;18(3):283-6. 162. Guralnik JM, Eisenstaedt RS, Ferrucci L, Klein HG, Woodman RC. Prevalence of anemia in persons 65 years and older in the United States: evidence for a high rate of unexplained anemia. Blood. 2004;104(8):2263-8. 163. Lopez A, Cacoub P, Macdougall IC, Peyrin-Biroulet L. Iron deficiency anaemia. Lancet. 2016;387(10021):907-16. 164. Pasricha SR, Tye-Din J, Muckenthaler MU, Swinkels DW. Iron deficiency. Lancet. 2021;397(10270):233-48. 165. Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig L, et al. STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. BMJ. 2015;351:h5527. 166. Rosa B, Margalit-Yehuda R, Gatt K, Sciberras M, Girelli C, Saurin JC, et al. Scoring systems in clinical small-bowel capsule endoscopy: all you need to know! Endosc Int Open. 2021;9(6):E802-E23. 167. Sealock RJ, Thrift AP, El-Serag HB, Sellin J. Long-term follow up of patients with obscure gastrointestinal bleeding examined with video capsule endoscopy. Medicine (Baltimore). 2018;97(29):e11429. 168. Olano C, Pazos X, Avendaño K, Calleri A, Ketzoian C. Diagnostic yield and predictive factors of findings in small-bowel capsule endoscopy in the setting of iron-deficiency anemia. Endosc Int Open. 2018;6(6):E688-E93. 169. Yung DE, Vijayan S, Avni T, Douglas S, Kopylov U, Koulaouzidis A. Fecal occult blood testing for the prediction of small-bowel pathology detected by capsule endoscopy: a systematic review and meta-analysis. Ann Gastroenterol. 2017;30(2):186-91. 170. Endo H, Kato T, Sakai E, Taniguchi L, Arimoto J, Kawamura H, et al. Is a fecal occult blood test a useful tool for judging whether to perform capsule endoscopy in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy? J Gastroenterol. 2017;52(2):194-202. 171. Efthymiou M, Allen PB, Jayasekera C, Taylor PV, Taylor AC. Value of fecal occult blood test as a screening test before capsule endoscopy. Eur J Gastroenterol Hepatol. 2011;23(8):690-4. 172. Kobayashi Y, Watabe H, Yamada A, Suzuki H, Hirata Y, Yamaji Y, et al. Impact of fecal occult blood on obscure gastrointestinal bleeding: observational study. World J Gastroenterol. 2015;21(1):326-32. 173. Levi Z, Gal E, Vilkin A, Chonen Y, Belfer RG, Fraser G, et al. Fecal immunochemical test and small bowel lesions detected on capsule endoscopy: results of a prospective study in patients with obscure occult gastrointestinal bleeding. Eur J Gastroenterol Hepatol. 2011;23(11):1024-8. 174. Judge C, Tighe D, Barry L, O'Neill J, Wong J, Shahin A, et al. Predicting pathology on small bowel capsule endoscopy: a good FIT. Endosc Int Open. 2019;7(11):E1379-E85. 175. Katsinelos P, Chatzimavroudis G, Terzoudis S, Patsis I, Fasoulas K, Katsinelos T, et al. Diagnostic yield and clinical impact of capsule endoscopy in obscure gastrointestinal 117 Page 118 of 129 bleeding during routine clinical practice: a single-center experience. Med Princ Pract. 2011;20(1):60-5. 176. Ko CW, Siddique SM, Patel A, Harris A, Sultan S, Altayar O, et al. AGA Clinical Practice Guidelines on the Gastrointestinal Evaluation of Iron Deficiency Anemia. Gastroenterology. 2020;159(3):1085-94. 177. Gerson LB, Fidler JL, Cave DR, Leighton JA. ACG Clinical Guideline: Diagnosis and Management of Small Bowel Bleeding. Am J Gastroenterol. 2015;110(9):1265-87; quiz 88. 178. Dickey S, Rockey DC. The Natural History of Iron Deficiency Anemia. Am J Med Sci. 2019;358(5):357-62. 179. Liao Z, Gao R, Xu C, Li Z-S. Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. Gastrointestinal endoscopy. 2010;71(2):280-6. 180. Wang X, Hu X, Xu Y, Yong J, Li X, Zhang K, et al. A systematic review on diagnosis and treatment of gastrointestinal diseases by magnetically controlled capsule endoscopy and artificial intelligence. Therapeutic Advances in Gastroenterology. 2023;16. 181. Gao Y, Cai MX, Tian B, Lin H, Jiang ZY, Yang XC, et al. Setting 6-Minute Minimal Examination Time Improves the Detection of Focal Upper Gastrointestinal Tract Lesions During Endoscopy: A Multicenter Prospective Study. Clin Transl Gastroenterol. 2023;14(8):e00612. 182. Jiang X, Pan J, Xu Q, Song YH, Sun HH, Peng C, et al. Diagnostic accuracy of magnetically guided capsule endoscopy with a detachable string for detecting oesophagogastric varices in adults with cirrhosis: prospective multicentre study. BMJ. 2024;384:e078581."],"dcterms:accessrights":["public"],"dc:title":["Pathology in the gastrointestinal tract causing anaemia- lesion location and the role of capsule endoscopy."],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["M.D"],"person:identifier.orcid":["0009000924055448"]},"updated_at":"2026-11-18T23:29:36Z"}