{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:36775"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:36775","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Characterising the Emission and Dispersion of Aerosols from the Toilet Plume and Quantification of the Associated Infection Risk","abstract":"Toilet flushing is known to generate aerosol plumes that can contain pathogenic microorganisms, and shared toilet facilities have been implicated in the transmission of infectious diseases. However, few studies have quantified the infection risks posed by these aerosols or investigated in detail how they disperse after flushing. This thesis presents an integrated analysis of airborne infection risks associated with toilet plume aerosols, combining controlled experimental studies, quantitative microbial risk assessment (QMRA), and computational fluid dynamics (CFD) simulations. The aim is to investigate aerosol generation, dispersion, and mitigation strategies in shared toilet settings. Controlled chamber experiments were conducted using a gravity-flow, close-coupled toilet, with and without a cubicle enclosure over a range of ventilation rates. The generation of aerosols was characterised by flushing a salt solution, revealing a large proportion of smaller particles (< 5 μm). Particle concentrations peaked in the first 1 min after flushing and returned to background levels within 10 min. Bioaerosol sampling using Escherichia coli showed that most bacteria were released in the first 5 min after flushing, with ventilation rates having a modest influence on airborne concentrations. Continuous but low-level bacterial deposition suggested cumulative risks from surface contamination. A QMRA framework was developed to assess the infection risks associated with single flushing events, accounting for transient aerosol dynamics and realistic occupancy durations. Two models were developed: one combining particle concentrations with estimated viral loads, and another using measured bioaerosol data. When applied to the experimental results, these models suggested non-negligible infection risks, particularly for pathogens present at high faecal concentrations, such as norovirus. The introduction of short delays (> 1 min) between toilet users significantly reduced the estimated infection risks. CFD simulations further examined aerosol dispersion and exposure risks, demonstrating how room layout, ventilation rate, and outlet positioning influence aerosol removal. Optimised ventilation strategies, including increased airflow and repositioned outlets, substantially reduced airborne particle concentrations. This research provides new insights and robust methods to evaluate and mitigate airborne infection risks from toilet plume aerosols, with implications for public health guidance and the design of safer shared toilet environments.","abstract_html":"Toilet flushing is known to generate aerosol plumes that can contain pathogenic microorganisms, and shared toilet facilities have been implicated in the transmission of infectious diseases. However, few studies have quantified the infection risks posed by these aerosols or investigated in detail how they disperse after flushing. This thesis presents an integrated analysis of airborne infection risks associated with toilet plume aerosols, combining controlled experimental studies, quantitative microbial risk assessment (QMRA), and computational fluid dynamics (CFD) simulations. The aim is to investigate aerosol generation, dispersion, and mitigation strategies in shared toilet settings. Controlled chamber experiments were conducted using a gravity-flow, close-coupled toilet, with and without a cubicle enclosure over a range of ventilation rates. The generation of aerosols was characterised by flushing a salt solution, revealing a large proportion of smaller particles (&lt; 5 μm). Particle concentrations peaked in the first 1 min after flushing and returned to background levels within 10 min. Bioaerosol sampling using Escherichia coli showed that most bacteria were released in the first 5 min after flushing, with ventilation rates having a modest influence on airborne concentrations. Continuous but low-level bacterial deposition suggested cumulative risks from surface contamination. A QMRA framework was developed to assess the infection risks associated with single flushing events, accounting for transient aerosol dynamics and realistic occupancy durations. Two models were developed: one combining particle concentrations with estimated viral loads, and another using measured bioaerosol data. When applied to the experimental results, these models suggested non-negligible infection risks, particularly for pathogens present at high faecal concentrations, such as norovirus. The introduction of short delays (&gt; 1 min) between toilet users significantly reduced the estimated infection risks. CFD simulations further examined aerosol dispersion and exposure risks, demonstrating how room layout, ventilation rate, and outlet positioning influence aerosol removal. Optimised ventilation strategies, including increased airflow and repositioned outlets, substantially reduced airborne particle concentrations. This research provides new insights and robust methods to evaluate and mitigate airborne infection risks from toilet plume aerosols, with implications for public health guidance and the design of safer shared toilet environments.","abstract_has_math":false,"creators":["Higham, Ciara Angel"],"institution":"University of Leeds","degree_name":"Integrated Ph.D and Master","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Fletcher, Louise A.","Noakes, Catherine J.","López-García, Martín"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-05","date_published":"2025-05","updated_at":"2026-11-18T23:29:36Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/S022732/1"],"render_values":[{"text":"EP/S022732/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000312138149"],"render_values":[{"text":"0000-0003-1213-8149","href":"https://orcid.org/0000-0003-1213-8149","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/36775/1/Higham_CA_Computing_PhD_2025.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A36775","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fletcher, Louise A.","Noakes, Catherine J.","López-García, Martín"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["UK Research and Innovation"]},{"key":"dc:creator","label":"Author","values":["Higham, Ciara Angel"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000312138149"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-05"]},{"key":"dc:date.issued","label":"Date","values":["2025-05"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Computing (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/36775/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] World Health Organization. Global technical consultation report on proposed terminology for pathogens that transmit through the air. [Online]. 2024. [Accessed 15 March 2025]. Available from: https://www.who.int/publications/m/item/global-technical-consultation-report-on-proposed-terminology-for-pathogens-that-transmit-through-the-air. [2] Johnson, D., Lynch, R., Marshall, C., Mead, K., and Hirst, D. Aerosol Generation by Modern Flush Toilets. [Online]. Aerosol Science and Technology. 2013, 47(9), pp.1047–1057. [Accessed 14 November 2023]. Available from: https://doi.org/10.1080/02786826.2013.814911. [3] Henning, D. N. Use of public washrooms in an enclosed, suburban shopping plaza. [Online]. National Research Council of Canada, 1977. [Accessed 4 January 2024]. Available from: https://doi.org/10.4224/20359222. [4] King, M.-F., Noakes, C., Sleigh, A., and Camargo-Valero, M. Bioaerosol deposition in single and two-bed hospital rooms: A numerical and experimental study. [Online]. Building and Environment. 2013, 59, pp.436–447. [Accessed 4 April 2024]. Available from: https://doi.org/10.1016/j.buildenv.2012. 09.011. [5] Lopez, G. U., Gerba, C. P., Tamimi, A. H., Kitajima, M., Maxwell, S. L., and Rose, J. B. Transfer efficiency of bacteria and viruses from porous and nonporous fomites to fingers under different relative humidity conditions. [Online]. Applied and Environmental Microbiology. 2013, 79(18), pp.5728– 5734. [Accessed 9 January 2023]. Available from: https://doi.org/10.1128/AEM.01030-13. [6] Lai, A. C. K., Tan, T. F., Li, W. S., and Ip, D. K. M. Emission strength of airborne pathogens during toilet flushing. [Online]. Indoor Air. 2018, 28(1), pp.73–79. [Accessed 3 September 2024]. Available from: https://doi.org/10.1111/ina.12406. [7] Zhang, T., Yao, L., Gao, Z., and Wang, F. Particle exposure risk to a lavatory user after flushing a squat toilet. [Online]. Scientific Reports. 2022, 12(1), article no: 21088 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1038/s41598-022-25106-4. [8] Li, P., Zhang, T., and Zhang, Y. Measuring the flushing-generated flow and aerosols in lavatory of commercial aircraft. [Online]. Building and Environment. 2022, 214, article no: 108948 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.108948. [9] Cai, C., Kim, P., Connor, T. H., Liu, Y., and Floyd, E. L. Reducing the particles generated by flushing institutional toilets. [Online]. Journal of Occupational and Environmental Hygiene. 2022, 19(5), pp.318–326. [Accessed 25 February 2025]. Available from: https://doi.org/10.1080/15459624. 2022.2053693. [10] Gerba, C. P., Wallis, C., and Melnick, J. L. Microbiological Hazards of Household Toilets: Droplet Production and the Fate of Residual Organisms. [Online]. Applied Microbiology. 1975, 30(2), pp.229–237. [Accessed 13 November 2023]. Available from: https://doi.org/10.1128/am.30.2.229-237.1975. [11] Darlow, H. M. and Bale, W. R. Infective hazards of water-closets. [Online]. The Lancet. 1959, 273(7084), pp.1196–1200. [Accessed 13 November 2023]. Available from: https://doi.org/10.1016/S0140-6736(59)91201-2. [12] Knowlton, S. D., Boles, C. L., Perencevich, E. N., Diekema, D. J., Nonnenmann, M. W., and CDC Epicenters Program. Bioaerosol concentrations generated from toilet flushing in a hospital-based patient care setting. [Online]. Antimicrobial Resistance & Infection Control. 2018, 7(1), article no: 16 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi. org/10.1186/s13756-018-0301-9. [13] Paddy, E. N., Afolabi, O. O. D., and Sohail, M. Exploring toilet plume bioaerosol exposure dynamics in public toilets using a Design of Experiments approach. [Online]. Scientific Reports. 2024, 14(1), article no: 10665 [no pagination]. [Accessed 21 February 2025]. Available from: https://doi.org/10. 1038/s41598-024-61039-w. [14] Haas, C. N., Rose, J. B., and Gerba, C. P. Quantitative Microbial Risk Assessment. [Online]. 2nd ed. Wiley, 2014. [Accessed 15 March 2024]. Available from: https://doi.org/10.1002/9781118910030. [15] Rangel, J. M., Sparling, P. H., Crowe, C., Griffin, P. M., and Swerdlow, D. L. Epidemiology of Escherichia coli O157:H7 Outbreaks, United States, 1982–2002. [Online]. Emerging Infectious Diseases. 2005, 11(4), pp.603–609. [Accessed 27 February 2025]. Available from: https://doi.org/10.3201/eid1104.040739. [16] Czepiel, J., Dróżdż, M., Pituch, H., Kuijper, E. J., Perucki, W., Mielimonka, A., Goldman, S., Wultańska, D., Garlicki, A., and Biesiada, G. Clostridium difficile infection: review. [Online]. European Journal of Clinical Microbiology & Infectious Diseases. 2019, 38(7), pp.1211–1221. [Accessed 5 November 2024]. Available from: https://doi.org/10.1007/s10096-019-03539-6. [17] Teunis, P. F. M., Sukhrie, F. H. A., Vennema, H., Bogerman, J., Beersma, M. F. C., and Koopmans, M. P. G. Shedding of norovirus in symptomatic and asymptomatic infections. [Online]. Epidemiology and Infection. 2015, 143(8), pp.1710–1717. [Accessed 20 November 2024]. Available from: https://doi. org/10.1017/S095026881400274X. [18] Crawford, S. E., Ramani, S., Tate, J. E., Parashar, U. D., Svensson, L., Hagbom, M., Franco, M. A., Greenberg, H. B., O’Ryan, M., Kang, G., Desselberger, U., and Estes, M. K. Rotavirus infection. [Online]. Nature Reviews Disease Primers. 2017, 3(1), pp.1–16. [Accessed 27 February 2025]. Available from: https://doi.org/10.1038/nrdp.2017.83. [19] McKinney, K. R., Gong, Y. Y., and Lewis, T. G. Environmental transmission of SARS at Amoy Gardens. [Online]. Journal of Environmental Health. 2006, 68(9), pp.26–52. [Accessed 6 February 2023]. Available from: https://pubmed.ncbi.nlm.nih.gov/32569870/. [20] Termansen, M. B. and Frische, S. Fecal-oral transmission of SARS-CoV-2: A systematic review of evidence from epidemiological and experimental studies. [Online]. American Journal of Infection Control. 2023, 51(12), pp.1430–1437. [Accessed 19 November 2024]. Available from: https://doi.org/10.1016/j. ajic.2023.04.170. [21] Tan, M., Tian, Y., Zhang, D., Wang, Q., and Gao, Z. Aerosol Transmission of Norovirus. [Online]. Viruses. 2024, 16(1), article no: 151 [no pagination]. [Accessed 16 May 2024]. Available from: https://doi.org/10.3390/v16010151. [22] Ahmed, S. M., Hall, A. J., Robinson, A. E., Verhoef, L., Premkumar, P., Parashar, U. D., Koopmans, M., and Lopman, B. A. Global prevalence of norovirus in cases of gastroenteritis: a systematic review and meta-analysis. [Online]. The Lancet. Infectious Diseases. 2014, 14(8), pp.725–730. [Accessed 9 February 2023]. Available from: https://doi.org/10.1016/S1473-3099(14) 70767-4. [23] Sandmann, F. G., Shallcross, L., Adams, N., Allen, D. J., Coen, P. G., Jeanes, A., Kozlakidis, Z., Larkin, L., Wurie, F., Robotham, J. V., Jit, M., and Deeny, S. R. Estimating the Hospital Burden of Norovirus-Associated Gastroenteritis in England and Its Opportunity Costs for Nonadmitted Patients. [Online]. Clinical Infectious Diseases. 2018, 67(5), pp.693–700. [Accessed 11 March 2025]. Available from: https://doi.org/10.1093/cid/ciy167. [24] Robilotti, E., Deresinski, S., and Pinsky, B. A. Norovirus. [Online]. Clinical Microbiology Reviews. 2015, 28(1), pp.134–164. [Accessed 21 January 2025]. Available from: https://doi.org/10.1128/CMR.00075-14. [25] UK Health Security Agency. National norovirus and rotavirus surveillance reports: 2024 to 2025 season. [Online]. 2025. [Accessed 11 February 2025]. Available from: https://www.gov.uk/government/statistics/national-norovirus-and-rotavirus-surveillance-reports-2024-to-2025-season/national-norovirus-and-rotavirus-report-week-10-report-data-to-week-8-data-up-to-23-february-2025. [26] NHS England. NHS norovirus pressure hits winter high. [Online]. 2025. [Accessed 18 March 2025]. Available from: https://www.england.nhs.uk/2025/01/nhs-norovirus-pressure-hits-winter-high/. [27] Alsved, M., Nyström, K., Thuresson, S., Nygren, D., Patzi-Churqui, M., Hussein, T., Fraenkel, C.-J., Medstrand, P., and Löndahl, J. Infectivity of exhaled SARS-CoV-2 aerosols is sufficient to transmit COVID-19 within minutes. [Online]. Scientific Reports. 2023, 13(1), article no: 21245 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1038/s41598-023-47829-8. [28] Hungerford, D., Vivancos, R., Read, J. M., Iturriza-Gomara, M., French, N., and Cunliffe, N. A. Rotavirus vaccine impact and socioeconomic deprivation: an interrupted time-series analysis of gastrointestinal disease outcomes across primary and secondary care in the UK. [Online]. BMC Medicine. 2018, 16(1), article no: 10 [no pagination]. [Accessed 11 March 2025]. Available from: https://doi.org/10.1186/s12916-017-0989-z. [29] Sadiq, A., Bostan, N., Yinda, K. C., Naseem, S., and Sattar, S. Rotavirus: Genetics, pathogenesis and vaccine advances. [Online]. Reviews in Medical Virology. 2018, 28(6), article no: e2003 [no pagination]. [Accessed 12 March 2024]. Available from: https://doi.org/10.1002/rmv.2003. [30] Wilde, J., Van, R., Pickering, L., Eiden, J., and Yolken, R. Detection of rotaviruses in the day care environment by reverse transcriptase polymerase chain reaction. [Online]. The Journal of Infectious Diseases. 1992, 166(3), pp.507–511. [Accessed 12 April 2024]. Available from: https://doi.org/10. 1093/infdis/166.3.507. [31] Bager, P., Svalgaard, I. B., Lomholt, F. K., Emborg, H.-D., Christiansen, L. E., Soborg, B., Hviid, A., and Vestergaard, L. S. The hospital and mortality burden of COVID-19 compared with influenza in Denmark: a national observational cohort study, 2022–24. [Online]. The Lancet Infectious Diseases. 2025, 0(0). [Accessed 11 March 2025]. Available from: https://doi.org/10. 1016/S1473-3099(24)00806-5. [32] Liu, E., Dean, C. A., and Elder, K. T. Editorial: The impact of COVID-19 on vulnerable populations. [Online]. Frontiers in Public Health. 2023, 11, article no: 1267723 [no pagination]. [Accessed 12 March 2025]. Available from: https://doi.org/10.3389/fpubh.2023.1267723. [33] Wu, Y., Guo, C., Tang, L., Hong, Z., Zhou, J., Dong, X., Yin, H., Xiao, Q., Tang, Y., Qu, X., Kuang, L., Fang, X., Mishra, N., Lu, J., Shan, H., Jiang, G., and Huang, X. Prolonged presence of SARS-CoV-2 viral RNA in faecal samples. [Online]. The Lancet Gastroenterology & Hepatology. 2020, 5(5), pp.434–435. [Accessed 11 March 2025]. Available from: https://doi. org/10.1016/S2468-1253(20)30083-2. [34] Kaper, J. B., Nataro, J. P., and Mobley, H. L. T. Pathogenic Escherichia coli. [Online]. Nature Reviews Microbiology. 2004, 2(2), pp.123–140. [Accessed 11 March 2025]. Available from: https://doi.org/10.1038/nrmicro818. [35] UK Health Security Agency. Annual epidemiological commentary: Gram-negative, MRSA, MSSA bacteraemia and C. difficile infections, up to and including financial year 2023 to 2024. [Online]. 2024. [Accessed 11 March 2025]. Available from: https://www.gov.uk/government/statistics/mrsa-mssa-and-e-coli-bacteraemia-and-c-difficile-infection-annual-epidemiological-commentary/annual-epidemiological-commentary-gram-negative-mrsa-mssa-bacteraemia-and-c-difficile-infections-up-to-and-including-financial-year-2023-to-2024. [36] Ludden, C., Coll, F., Gouliouris, T., Restif, O., Blane, B., Blackwell, G. A., Kumar, N., Naydenova, P., Crawley, C., Brown, N. M., Parkhill, J., and Peacock, S. J. Defining nosocomial transmission of Escherichia coli and antimicrobial resistance genes: a genomic surveillance study. [Online]. The Lancet Microbe. 2021, 2(9), pp.e472–e480. [Accessed 11 March 2025]. Available from: https://doi.org/10.1016/S2666-5247(21)00117-8. [37] Manning, S., Alcamo, I., and Heymann, D. Escherichia Coli Infections. [Online]. 3rd ed. Chelsea House, 2020. [Accessed 17 March 2025]. Available from: https://books.google.co.uk/books?id=UWmLEAAAQBAJ. [38] Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., and Ho, T. Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus. [Online]. New England Journal of Medicine. 2004, 350(17), pp.1731–1739. [Accessed 4 March 2025]. Available from: https://doi.org/10.1056/NEJMoa032867. [39] Kang, M., Wei, J., Yuan, J., Guo, J., Zhang, Y., Hang, J., Qu, Y., Qian, H., Zhuang, Y., Chen, X., Peng, X., Shi, T., Wang, J., Wu, J., Song, T., He, J., Li, Y., and Zhong, N. Probable Evidence of Fecal Aerosol Transmission of SARS-CoV-2 in a High-Rise Building. [Online]. Annals of Internal Medicine. 2020,173(12), pp.974–980. [Accessed 3 February 2023]. Available from: https://doi.org/10.7326/M20-0928. [40] Malki-Epshtein, L., Adzic, F., Roberts, B. M., Hathway, E. A., Iddon, C., Mustafa, M., and Cook, M. Measurement and rapid assessment of indoor air quality at mass gathering events to assess ventilation performance and reduce aerosol transmission of SARS-CoV-2. [Online]. Building Services Engineering Research & Technology. 2023, 44(2), pp.113–133. [Accessed 19 February 2025]. Available from: https://doi.org/10.1177/01436244221137995. [41] Ali, W., Hu, Z., Tang, Z.-R., Liu, S.-Y., Nasir, Z. A., Coulon, F., Liu, P., and Yan, C. Quantitative microbial risk assessment of bioaerosol emissions from squat and bidet toilets during flushing. [Online]. Risk Analysis. 2025. [Accessed 6 June 2024]. Available from: https://doi.org/10.1111/risa. 70000. [42] Denpetkul, T., Pumkaew, M., Sittipunsakda, O., Leaungwutiwong, P., Mongkolsuk, S., and Sirikanchana, K. Effects of face masks and ventilation on the risk of SARS-CoV-2 respiratory transmission in public toilets: a quantitative microbial risk assessment. [Online]. Journal of Water and Health. 2022, 20(2), pp.300–313. [Accessed 1 March 2025]. Available from: https://doi.org/10. 2166/wh.2022.190. [43] Goforth, M. P., Boone, S. A., Clark, J., Valenzuela, P. B., McKinney, J., Ijaz, M. K., and Gerba, C. P. Impacts of lid closure during toilet flushing and of toilet bowl cleaning on viral contamination of surfaces in United States restrooms. [Online]. American Journal of Infection Control. 2024, 52(2), pp.141–146. [Accessed 8 March 2024]. Available from: https://doi.org/10.1016/j.ajic.2023.11.020. [44] Johnson, D. L., Lynch, R. A., Villanella, S. M., Jones, J. F., Fang, H., Mead, K. R., and Hirst, D. V. L. Persistence of Bowl Water Contamination during Sequential Flushes of Contaminated Toilets. [Online]. Journal of environmental health. 2017, 80(3), pp.34–49. [Accessed 31 January 2025]. Available from: https://pubmed.ncbi.nlm.nih.gov/29651169/. [45] Best, E. L., Sandoe, J. A. T., and Wilcox, M. H. Potential for aerosolization of Clostridium difficile after flushing toilets: the role of toilet lids in reducing environmental contamination risk. [Online]. Journal of Hospital Infection. 2012, 80(1), pp.1–5. [Accessed 13 February 2024]. Available from: https://doi.org/10.1016/j.jhin.2011.08.010. [46] Abney, S., Bright, K., McKinney, J., Ijaz, M. K., and Gerba, C. Toilet hygiene—review and research needs. [Online]. Journal of Applied Microbiology. 2021, 131(6), pp.2705–2714. [Accessed 22 February 2025]. Available from: https://doi.org/10.1111/jam.15121. [47] Barker, J. and Bloomfield, S. F. Survival of Salmonella in bathrooms and toilets in domestic homes following salmonellosis. [Online]. Journal of Applied Microbiology. 2000, 89(1), pp.137–144. [Accessed 4 April 2023]. Available from: https://doi.org/10.1046/j.1365-2672.2000.01091.x. [48] Abney, S. E., Higham, C. A., Wilson, A. M., Ijaz, M. K., McKinney, J., Reynolds, K. A., and Gerba, C. P. Transmission of Viruses from Restroom Use: A Quantitative Microbial Risk Assessment. [Online]. Food and Environmental Virology. 2024, 16(1), pp.65–78. [Accessed 13 September 2024]. Available from: https://doi.org/10.1007/s12560-023-09580-1. [49] Barker, J. and Jones, M. V. The potential spread of infection caused by aerosol contamination of surfaces after flushing a domestic toilet. [Online]. Journal of Applied Microbiology. 2005, 99(2), pp.339–347. [Accessed 3 February 2024]. Available from: https://doi.org/10.1111/j.1365-2672.2005. 02610.x. [50] Ali, W., An, D.-z., Yang, Y.-f., Cui, B.-b., Ma, J.-x., Zhu, H., Li, M., Ai, X.-J., and Yan, C. Comparing bioaerosol emission after flushing in squat and bidet toilets: Quantitative microbial risk assessment for defecation and hand washing postures. [Online]. Building and Environment. 2022, 221, article no: 109284 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.109284. [51] Amoah, I. D., Pillay, L., Deepnarian, N., Awolusi, O., Pillay, K., Ramlal, P., Kumari, S., and Bux, F. Detection of SARS-CoV-2 RNA on contact surfaces within shared sanitation facilities. [Online]. International Journal of Hygiene and Environmental Health. 2021, 236, article no: 113807 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.ijheh.2021.113807. [52] Crimaldi, J. P., True, A. C., Linden, K. G., Hernandez, M. T., Larson, L. T., and Pauls, A. K. Commercial toilets emit energetic and rapidly spreading aerosol plumes. [Online]. Scientific Reports. 2022, 12(1), article no: 20493 [no pagination]. [Accessed 1 October 2023]. Available from: https://doi. org/10.1038/s41598-022-24686-5. [53] Jessen, C. U. Airborne Microorganisms: Occurrance and Control. [Online]. G.E.C. Gad Forlag, Copenhagen. 1955. [Accessed 2 February 2023]. [54] Newsom, S. W. B. Microbiology of hospital toilets. [Online]. The Lancet. 1972, 300(7779), pp.700–703. [Accessed 24 February 2025]. Available from: https://doi.org/10.1016/S0140-6736(72)92102-2. [55] Flügge, C. Ueber Luftinfection. [Online]. Zeitschrift für Hygiene und Infectionskrankheiten. 1897, 25(1), pp.179–224. [Accessed 3 March 2023]. Available from: https://doi.org/10.1007/BF02220473. [56] Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., and Katoshevski, D. Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities. [Online]. Journal of Aerosol Science. 2009, 40(3), pp.256–269. [Accessed 15 January 2025]. Available from: https://doi.org/10.1016/j.jaerosci.2008.11.002. [57] Johnson, G. R., Morawska, L., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Chao, C. Y. H., Wan, M. P., Li, Y., Xie, X., Katoshevski, D., and Corbett, S. Modality of human expired aerosol size distributions. [Online]. Journal of Aerosol Science. 2011, 42(12), pp.839–851. [Accessed 24 February 2025]. Available from: https://doi.org/10.1016/j.jaerosci.2011.07.009. [58] Foat, T. G., Higgins, B., Abbs, C., Maishman, T., Coldrick, S., Kelsey, A., Ivings, M. J., Parker, S. T., and Noakes, C. J. Modeling the effect of temperature and relative humidity on exposure to SARS-CoV-2 in a mechanically ventilated room. [Online]. Indoor Air. 2022, 32(11), article no: e13146 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1111/ina.13146. [59] Stettler, M. E. J., Nishida, R. T., Oliveira, P. M. de, Mesquita, L. C. C., Johnson, T. J., Galea, E. R., Grandison, A., Ewer, J., Carruthers, D., Sykes, D., Kumar, P., Avital, E., Obeysekara, A. I. B., Doorly, D., Hardalupas, Y., Green, D. C., Coldrick, S., Parker, S., and Boies, A. M. Source terms for benchmarking models of SARS-CoV-2 transmission via aerosols and droplets. [Online]. Royal Society Open Science. 2022, 9(5), article no: 212022 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10. 1098/rsos.212022. [60] Calmet, H., Inthavong, K., Both, A., Surapaneni, A., Mira, D., Egukitza, B., and Houzeaux, G. Large eddy simulation of cough jet dynamics, droplet transport, and inhalability over a ten minute exposure. [Online]. Physics of Fluids. 2021, 33(12), article no: 125122 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1063/5.0072148. [61] Coldrick, S., Kelsey, A., Ivings, M. J., Foat, T. G., Parker, S. T., Noakes, C. J., Bennett, A., Rickard, H., and Moore, G. Modeling and experimental study of dispersion and deposition of respiratory emissions with implications for disease transmission. [Online]. Indoor Air. 2022, 32(2), article no: e13000 [no pagination]. [Accessed 13 November 2024]. Available from: https://doi. org/10.1111/ina.13000. [62] Oliveira, P. M. de, Mesquita, L. C. C., Gkantonas, S., Giusti, A., and Mastorakos, E. Evolution of spray and aerosol from respiratory releases: theoretical estimates for insight on viral transmission. [Online]. Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences. 2021, 477(2245), article no: 20200584 [no pagination]. [Accessed 15 January 2025]. Available from: https://doi.org/10.1098/rspa.2020.0584. [63] Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., and Olin, A.-C. Exhaled particles and small airways. [Online]. Respiratory Research. 2019, 20(1), article no: 8 [no pagination]. [Accessed 15 January 2025]. Available from: https://doi.org/10.1186/s12931-019-0970-9. [64] Fennelly, K. P. Particle sizes of infectious aerosols: implications for infection control. [Online]. The Lancet. Respiratory Medicine. 2020, 8(9), pp.914–924. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/S2213-2600(20)30323-4. [65] Gregson, F. K., Watson, N. A., Orton, C. M., Haddrell, A. E., McCarthy, L. P., Finnie, T. J., Gent, R., Donaldson, G. C., Shah, P. L., Calder, J. D., Bzdek, B. R., Costello, D., and Reid, J. P. Comparing aerosol concentrations and particle size distributions generated by singing, speaking and breathing. [Online]. Aerosol Science and Technology. 2021, 55(6), pp.681–691. [Accessed 15 January 2025]. Available from: https://doi.org/10.1080/02786826.2021. 1883544. [66] Yan, J., Grantham, M., Pantelic, J., Bueno de Mesquita, P. J., Albert, B., Liu, F., Ehrman, S., Milton, D. K., and EMIT Consortium. Infectious virus in exhaled breath of symptomatic seasonal influenza cases from a college community. [Online]. Proceedings of the National Academy of Sciences. 2018, 115(5), pp.1081–1086. [Accessed 24 February 2025]. Available from: https://doi.org/10.1073/pnas.1716561115. [67] Lindsley, W. G., Noti, J. D., Blachere, F. M., Thewlis, R. E., Martin, S. B., Othumpangat, S., Noorbakhsh, B., Goldsmith, W. T., Vishnu, A., Palmer, J. E., Clark, K. E., and Beezhold, D. H. Viable Influenza A Virus in Airborne Particles from Human Coughs. [Online]. Journal of Occupational and Environmental Hygiene. 2015, 12(2), pp.107–113. [Accessed 24 February 2025]. Available from: https://doi.org/10.1080/15459624.2014.973113. [68] Coleman, K. K., Tay, D. J. W., Tan, K. S., Ong, S. W. X., Than, T. S., Koh, M. H., Chin, Y. Q., Nasir, H., Mak, T. M., Chu, J. J. H., Milton, D. K., Chow, V. T. K., Tambyah, P. A., Chen, M., and Tham, K. W. Viral Load of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Respiratory Aerosols Emitted by Patients With Coronavirus Disease 2019 (COVID-19) While Breathing, Talking, and Singing. [Online]. Clinical Infectious Diseases.2022, 74(10), pp.1722–1728. [Accessed 8 July 2024]. Available from: https://doi.org/10.1093/cid/ciab691. [69] Malik, M. and Kunze, T. Detection of SARS-CoV-2 RNA in exhaled breath and its potential for prevention measures. [Online]. Infection Prevention in Practice. 2023, 5(3), article no: 100299 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1016/j.infpip.2023.100299. [70] Lane, G., Zhou, G., Hultquist, J. F., Simons, L. M., Redondo, R. L., Ozer, E. A., McCarthy, D. M., Ison, M. G., Achenbach, C. J., Wang, X., Wai, C. M., Wyatt, E., Aalsburg, A., Yang, Q., Noto, T., Alisoltani, A., Ysselstein, D., Awatramani, R., Murphy, R., Theron, G., and Zelano, C. [Pre-print] Quantity of SARS-CoV-2 RNA copies exhaled per minute during natural breathing over the course of COVID-19 infection. [Online]. eLife. 2024. [Accessed 24 February 2025]. Available from: https://doi.org/10.7554/eLife.91686.1. [71] Leung, N. H. L., Chu, D. K. W., Shiu, E. Y. C., Chan, K.-H., McDevitt, J. J., Hau, B. J. P., Yen, H.-L., Li, Y., Ip, D. K. M., Peiris, J. S. M., Seto, W.-H., Leung, G. M., Milton, D. K., and Cowling, B. J. Respiratory virus shedding in exhaled breath and efficacy of face masks. [Online]. Nature Medicine. 2020, 26(5), pp.676–680. [Accessed 24 February 2025]. Available from: https:// doi.org/10.1038/s41591-020-0843-2. [72] Fabian, P., Brain, J., Houseman, E. A., Gern, J., and Milton, D. K. Origin of exhaled breath particles from healthy and human rhinovirus-infected subjects. [Online]. Journal of Aerosol Medicine and Pulmonary Drug Delivery. 2011, 24(3), pp.137–147. [Accessed 10 October 2024]. Available from: https://doi.org/10.1089/jamp.2010.0815. [73] Ghumra, D. P., Shetty, N., McBrearty, K. R., Puthussery, J. V., Sumlin, B. J., Gardiner, W. D., Doherty, B. M., Magrecki, J. P., Brody, D. L., Esparza, T. J., O’Halloran, J. A., Presti, R. M., Bricker, T. L., Boon, A. C. M., Yuede, C. M., Cirrito, J. R., and Chakrabarty, R. K. Rapid Direct Detection of SARS-CoV-2 Aerosols in Exhaled Breath at the Point of Care. [Online]. ACS Sensors. 2023, 8(8), pp.3023–3031. [Accessed 24 February 2025]. Available from: https://doi.org/10.1021/acssensors.3c00512. [74] Lai, J., Coleman, K. K., Tai, S. H. S., German, J., Hong, F., Albert, B., Esparza, Y., Srikakulapu, A. K., Schanz, M., Maldonado, I. S., Oertel, M., Fadul, N., Gold, T. L., Weston, S., Mullins, K., McPhaul, K. M., Frieman, M., and Milton, D. K. Exhaled Breath Aerosol Shedding of Highly Transmissible Versus Prior Severe Acute Respiratory Syndrome Coronavirus 2 Variants. [Online]. Clinical Infectious Diseases. 2022, 76(5), pp.786–794. [Accessed 24 February 2025]. Available from: https://doi.org/10.1093/cid/ciac846. [75] Adenaiye, O. O., Lai, J., Bueno de Mesquita, P. J., Hong, F., Youssefi, S., German, J., Tai, S. H. S., Albert, B., Schanz, M., Weston, S., Hang, J., Fung, C., Chung, H. K., Coleman, K. K., Sapoval, N., Treangen, T., Berry, I. M., Mullins, K., Frieman, M., Ma, T., and Milton, D. K. Infectious Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Exhaled Aerosols and Efficacy of Masks During Early Mild Infection. [Online]. Clinical Infectious Diseases. 2021, 75(1), pp.e241–e248. [Accessed 24 February 2025]. Available from: https://doi.org/10.1093/cid/ciab797. [76] Zheng, Y., Chen, H., Yao, M., and Li, X. Bacterial pathogens were detected from human exhaled breath using a novel protocol. [Online]. Journal of Aerosol Science. 2018, 117, pp.224–234. [Accessed 24 February 2025]. Available from: https://doi.org/10.1016/j.jaerosci.2017.12.009. [77] Anisuzzaman, n., Hossain, M. S., Hatta, T., Labony, S. S., Kwofie, K. D., Kawada, H., Tsuji, N., and Alim, M. A. Food- and vector-borne parasitic zoonoses: Global burden and impacts. [Online]. Advances in Parasitology. 2023, 120, pp.87–136. [Accessed 15 March 2025]. Available from: https://doi.org/10.1016/bs.apar.2023.02.001. [78] Abney, S. E., Ijaz, M. K., McKinney, J., and Gerba, C. P. Laundry Hygiene and Odor Control: State of the Science. [Online]. Applied and Environmental Microbiology. 2021, 87(14), article no: e03002-20 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1128/AEM.03002-20. [79] Rashid, T., VonVille, H., Hasan, I., and Garey, K. Shoe soles as a potential vector for pathogen transmission: a systematic review. [Online]. Journal of Applied Microbiology. 2016, 121(5), pp.1223–1231. [Accessed 24 February 2025]. Available from: https://doi.org/10.1111/jam.13250. [80] Wells, W. F. On Air-borne infection Study II. Droplets and Droplet Nuclei. [Online]. American Journal of Epidemiology. 1934, 20(3), pp.611–618. [Accessed 14 December 2023]. Available from: https://doi.org/10.1093/oxfordjournals.aje.a118097. [81] Randall, K., Ewing, E. T., Marr, L. C., Jimenez, J. L., and Bourouiba, L. How did we get here: what are droplets and aerosols and how far do they go? A historical perspective on the transmission of respiratory infectious diseases. [Online]. Interface Focus. 2021, 11(6), article no: 20210049 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1098/rsfs.2021.0049. [82] Sayers, R. R. and Jones, R. R. Silicosis and Similar Dust Diseases: Medical Aspects and Control. [Online]. Public Health Reports (1896-1970). 1938, 53(33), pp.1453–1472. [Accessed 25 February 2025]. Available from: https://doi.org/10.2307/4582633. [83] Wijk, A. M. V. and Patterson, H. S. The Percentage of Particles of Different Sizes Removed from Dust-Laden Air by Breathing. [Online]. Journal of Industrial Hygiene. 1940, 22, pp.31–35. [Accessed 25 February 2025]. Available from: https://www.cabdirect.org/cabdirect/abstract/19422200462. [84] Langmuir, A. D. The Potentialities of Biological Warfare against Man: An Epidemiological Appraisal. [Online]. Public Health Reports (1896-1970). 1951, 66(13), pp.387–399. [Accessed 15 January 2025]. Available from: https://doi.org/10.2307/4587679. [85] Wells, W. F. Airborne Contagion and Air Hygiene: An Ecological Study of Droplet Infections. [Online]. Journal of the American Medical Association. 1955, 159(1), p.90. [Accessed 15 January 2025]. Available from: https://doi.org/10.1001/jama.1955.02960180092033. [86] Bourouiba, L. Turbulent Gas Clouds and Respiratory Pathogen Emissions: Potential Implications for Reducing Transmission of COVID-19. [Online]. JAMA. 2020, 323(18), pp.1837–1838. [Accessed 18 December 2024]. Available from: https://doi.org/10.1001/jama.2020.4756. [87] Hou, Y. J., Okuda, K., Edwards, C. E., Martinez, D. R., Asakura, T., Dinnon, K. H., Kato, T., Lee, R. E., Yount, B. L., Mascenik, T. M., Chen, G., Olivier, K. N., Ghio, A., Tse, L. V., Leist, S. R., Gralinski, L. E., Schäfer, A., Dang, H., Gilmore, R., Nakano, S., Sun, L., Fulcher, M. L., Livraghi-Butrico, A., Nicely, N. I., Cameron, M., Cameron, C., Kelvin, D. J., Silva, A. de, Margolis, D. M., Markmann, A., Bartelt, L., Zumwalt, R., Martinez, F. J., Salvatore, S. P., Borczuk, A., Tata, P. R., Sontake, V., Kimple, A., Jaspers, I., O’Neal, W. K., Randell, S. H., Boucher, R. C., and Baric, R. S. SARS-CoV-2 Reverse Genetics Reveals a Variable Infection Gradient in the Respiratory Tract. [Online]. Cell. 2020, 182(2), pp.429–446. [Accessed 15 March 2025]. Available from: https://doi.org/10.1016/j.cell.2020.05.042. [88] Chin, A. W. H., Chu, J. T. S., Perera, M. R. A., Hui, K. P. Y., Yen, H.-L., Chan, M. C. W., Peiris, M., and Poon, L. L. M. Stability of SARS-CoV-2 in different environmental conditions. [Online]. The Lancet Microbe. 2020, 1(1), p.e10. [Accessed 15 January 2025]. Available from: https://doi.org/10 .1016/S2666-5247(20)30003-3. [89] Biryukov, J., Boydston, J. A., Dunning, R. A., Yeager, J. J., Wood, S., Reese, A. L., Ferris, A., Miller, D., Weaver, W., Zeitouni, N. E., Phillips, A., Freeburger, D., Hooper, I., Ratnesar-Shumate, S., Yolitz, J., Krause, M., Williams, G., Dawson, D. G., Herzog, A., Dabisch, P., Wahl, V., Hevey, M. C., and Altamura, L. A. Increasing Temperature and Relative Humidity Accelerates Inactivation of SARS-CoV-2 on Surfaces. [Online]. mSphere. 2020, 5(4), article no: e00441-20 [no pagination]. [Accessed 15 January 2025]. Available from: https://doi.org/10.1128/msphere.00441-20. [90] McEldowney, S. and Fletcher, M. The effect of temperature and relative humidity on the survival of bacteria attached to dry solid surfaces. [Online]. Letters in Applied Microbiology. 1988, 7(4), pp.83–86. [Accessed 25 February 2025]. Available from: https://doi.org/10.1111/j.1472-765X.1988.tb01258.x. [91] Pal, R., Sarkar, S., and Mukhopadhyay, A. Influence of ambient conditions on evaporation and transport of respiratory droplets in indoor environment. [Online]. International Communications in Heat and Mass Transfer. 2021, 129, article no: 105750 [no pagination]. [Accessed 15 January 2025]. Available from: https://doi.org/10.1016/j.icheatmasstransfer.2021.105750. [92] Walker, M. D., Vincent, J. C., Benson, L., Stone, C. A., Harris, G., Ambler, R. E., Watts, P., Slatter, T., López-García, M., King, M.-F., Noakes, C. J., and Thomas, R. J. Effect of Relative Humidity on Transfer of Aerosol Deposited Artificial and Human Saliva from Surfaces to Artificial Finger Pads. [Online]. Viruses. 2022, 14(5), article no: 1048 [no pagination]. [Accessed 2 January 2025]. Available from: https://doi.org/10.3390/v14051048. [93] Liu, F., Qian, H., Luo, Z., Wang, S., and Zheng, X. A laboratory study of the expiratory airflow and particle dispersion in the stratified indoor environment. [Online]. Building and Environment. 2020, 180, article no: 106988 [no pagination]. [Accessed 12 March 2025]. Available from: https://doi.org/10. 1016/j.buildenv.2020.106988. [94] Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., and Chwang, A. T. Y. Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems. [Online]. Indoor Air. 2006, 16(2), pp.111– 128. [Accessed 12 March 2025]. Available from: https://doi.org/10.1111/j.1600-0668.2005.00407.x. [95] Sze To, G. N., Wan, M. P., Chao, C. Y. H., Fang, L., and Melikov, A. Experimental Study of Dispersion and Deposition of Expiratory Aerosols in Aircraft Cabins and Impact on Infectious Disease Transmission. [Online]. Aerosol Science and Technology. 2009, 43(5), pp.466–485. [Accessed 18 March 2025]. Available from: https://doi.org/10.1080/02786820902736658. [96] Sun, S., Li, J., and Han, J. How human thermal plume influences near-human transport of respiratory droplets and airborne particles: a review. [Online]. Environmental Chemistry Letters. 2021, 19(3), pp.1971–1982. [Accessed 12 March 2025]. Available from: https://doi.org/10.1007/s10311-020-01178-4. [97] Hobday, R. A. and Dancer, S. J. Roles of sunlight and natural ventilation for controlling infection: historical and current perspectives. [Online]. Journal of Hospital Infection. 2013, 84(4), pp.271–282. [Accessed 12 March 2025]. Available from: https://doi.org/10.1016/j.jhin.2013.04.011. [98] Raiteux, J., Eschlimann, M., Marangon, A., Rogée, S., Dadvisard, M., Taysse, L., and Larigauderie, G. Inactivation of SARS-CoV-2 by Simulated Sunlight on Contaminated Surfaces. [Online]. Microbiology Spectrum. 2021, 9(1), article no: e0033321 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10.1128/spectrum.00333-21. [99] Schuit, M., Gardner, S., Wood, S., Bower, K., Williams, G., Freeburger, D., and Dabisch, P. The Influence of Simulated Sunlight on the Inactivation of Influenza Virus in Aerosols. [Online]. The Journal of Infectious Diseases. 2020, 221(3), pp.372–378. [Accessed 11 August 202]. Available from: https://doi.org/10.1093/infdis/jiz582. [100] West, R., Michie, S., Rubin, G. J., and Amlôt, R. Applying principles of behaviour change to reduce SARS-CoV-2 transmission. [Online]. Nature Human Behaviour. 2020, 4(5), pp.451–459. [Accessed 15 January 2025]. Available from: https://doi.org/10.1038/s41562-020-0887-9. [101] Mousa, A., Winskill, P., Watson, O. J., Ratmann, O., Monod, M., Ajelli, M., Diallo, A., Dodd, P. J., Grijalva, C. G., Kiti, M. C., Krishnan, A., Kumar, R., Kumar, S., Kwok, K. O., Lanata, C. F., Waroux, O. L. P. de, Leung, K., Mahikul, W., Melegaro, A., Morrow, C. D., Mossong, J., Neal, E. F., Nokes, D. J., Panngum, W., Potter, G. E., Russell, F. M., Saha, S., Sugimoto, J. D., Wei, W. I., Wood, R. R., Wu, J., Zhang, J., Walker, P., and Whittaker, C. Social contact patterns and implications for infectious disease transmission – a systematic review and meta-analysis of contact surveys. [Online]. eLife. 2021, 10, article no: e70294 [no pagination]. [Accessed 12 March 2025]. Available from: https://doi.org/10.7554/eLife.70294. [102] Marks, M., Millat-Martinez, P., Ouchi, D., Roberts, C. h., Alemany, A., Corbacho-Monné, M., Ubals, M., Tobias, A., Tebé, C., Ballana, E., Bassat, Q., Baro, B., Vall-Mayans, M., G-Beiras, C., Prat, N., Ara, J., Clotet, B., and Mitjà, O. Transmission of COVID-19 in 282 clusters in Catalonia, Spain: a cohort study. [Online]. The Lancet Infectious Diseases. 2021, 21(5), pp.629–636. [Accessed 15 January 2025]. Available from: https://doi.org/10.1016/S1473-3099(20)30985-3. [103] Marc, A., Kerioui, M., Blanquart, F., Bertrand, J., Mitjà, O., Corbacho-Monné, M., Marks, M., and Guedj, J. Quantifying the relationship between SARS-CoV-2 viral load and infectiousness. [Online]. eLife. 2021, 10, article no: e69302 [no pagination]. [Accessed 2 February 2025]. Available from: https://doi.org/10.7554/eLife.69302. [104] Memoli, M. J., Czajkowski, L., Reed, S., Athota, R., Bristol, T., Proudfoot, K., Fargis, S., Stein, M., Dunfee, R. L., Shaw, P. A., Davey, R. T., and Taubenberger, J. K. Validation of the Wild-type Influenza A Human Challenge Model H1N1pdMIST: An A(H1N1)pdm09 Dose-Finding Investigational New Drug Study. [Online]. Clinical Infectious Diseases. 2015, 60(5), pp.693–702. [Accessed 25 February 2025]. Available from: https://doi.org/10.1093/cid/ciu924. [105] Mayer, B. T., Krantz, E. M., Wald, A., Corey, L., Casper, C., Gantt, S., and Schiffer, J. T. Estimating the Risk of Human Herpesvirus 6 and Cytomegalovirus Transmission to Ugandan Infants from Viral Shedding in Saliva by Household Contacts. [Online]. Viruses. 2020, 12(2), article no: 171 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10. 3390/v12020171. [106] Boucoiran, I., Mayer, B. T., Krantz, E. M., Marchant, A., Pati, S., Boppana, S., Wald, A., Corey, L., Casper, C., Schiffer, J. T., and Gantt, S. Non-Primary Maternal CMV Infection Following Viral Shedding in Infants. [Online]. The Pediatric infectious disease journal. 2018, 37(7), pp.627–631. [Accessed 25 February 2025]. Available from: https://doi.org/10.1097/INF. 0000000000001877. [107] Zeng, L., Li, J., Lv, M., Li, Z., Yao, L., Gao, J., Wu, Q., Wang, Z., Yang, X., Tang, G., Qu, G., and Jiang, G. Environmental Stability and Transmissibility of Enveloped Viruses at Varied Animate and Inanimate Interfaces. [Online]. Environment & Health. 2023, 1(1), pp.15–31. [Accessed 12 March 2025]. Available from: https://doi.org/10.1021/envhealth.3c00005. [108] Vasickova, P., Pavlik, I., Verani, M., and Carducci, A. Issues Concerning Survival of Viruses on Surfaces. [Online]. Food and Environmental Virology. 2010, 2(1), pp.24–34. [Accessed 12 March 2025]. Available from: https://doi.org/10.1007/s12560-010-9025-6. [109] Katzenberger, R. H., Rösel, A., and Vonberg, R.-P. Bacterial survival on inanimate surfaces: a field study. [Online]. BMC Research Notes. 2021, 14(1), article no: 97 [no pagination]. [Accessed 12 March 2025]. Available from: https://doi.org/10.1186/s13104-021-05492-0. [110] Kreider, J., Curtiss, P., and Rabl, A. Heating and Cooling of Buildings: Design for Efficiency. [Online]. 3rd ed. CRC Press, 2016. [Accessed 17 March 2025]. Available from: https://doi.org/10.1201/9781315374567-24. [111] Scientific Advisory Group for Emergencies. Environmental Modelling Group: Role of ventilation in controlling SARS-CoV-2 transmission. [Online]. 2020. [Accessed 15 March 2025]. Available from: https://www.gov.uk/government/publications/emg-role-of-ventilation-in-controlling-sars-cov-2-transmission-30-september-2020. [112] Lipinski, T., Ahmad, D., Serey, N., and Jouhara, H. Review of ventilation strategies to reduce the risk of disease transmission in high occupancy buildings. [Online]. International Journal of Thermofluids. 2020, 7-8, article no: 100045 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1016/j.ijft.2020.100045. [113] Department for Levelling Up, Housing and Communities. The Building Regulations 2010. Approved Document F: Ventilation. [Online]. HM Government, 2021. [Accessed 3 December 2025]. Available from: https://www.gov.uk/government/publications/ventilation-approved-document-f. [114] Roberts, B. M., Adzic, F., Hathway, E. A., Iddon, C., Jones, B., Cook, M. J., and Malki-Epshtein, L., Measurement of ventilation effectiveness and indoor air quality in toilets at mass gathering events. In: 43rd AIVC, 11th TightVent Conference and 9th Venticool Conference 2023, 4 - 5 October 2023, Copenhagen. [Online]. AIVC, 2023, pp.575–584. [Accessed 13 March 2025]. Available from: https://www.aivc.org/resource/measurement-ventilation-effectiveness-and-indoor-air-quality-toilets-mass-gathering-events?volume=39582. [115] Lee, M. C. J. and Tham, K. W. Public toilets with insufficient ventilation present high cross infection risk. [Online]. Scientific Reports. 2021, 11(1), article no: 20623 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10.1038/s41598-021-00166-0. [116] Jung, J., Lee, J., Jo, S., Bae, S., Kim, J. Y., Cha, H. H., Lim, Y.-J., Kwak, S. H., Hong, M. J., Kim, E. O., Bae, J.-Y., Kang, C., Sung, M., Park, M.-S., and Kim, S.-H. Nosocomial Outbreak of COVID-19 in a Hematologic Ward. [Online]. Infection & Chemotherapy. 2021, 53(2), pp.332–341. [Accessed 8 March 2024]. Available from: https://doi.org/10.3947/ic.2021.0046. [117] Li, T., Katz, A., Osei-Twum, J.-A., James, L., Leung, V., Bozek, P., Persaud, N., O’Campo, P., and Siegel, J. A. Science tells us that portable air filters reduce infection risk. It’s time for public health authorities to make this clear. [Online]. Journal of Infection and Public Health. 2025, 18(3), article no: 102650 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.jiph.2024.102650. [118] Buising, K. L., Schofield, R., Irving, L., Keywood, M., Stevens, A., Keogh, N., Skidmore, G., Wadlow, I., Kevin, K., Rismanchi, B., Wheeler, A. J., Humphries, R. S., Kainer, M., Monty, J., McGain, F., and Marshall, C. Use of portable air cleaners to reduce aerosol transmission on a hospital coronavirus disease 2019 (COVID-19) ward. [Online]. Infection Control and Hospital Epidemiology. 2022, 43(8), pp.987–992. [Accessed 17 March 2025]. Available from: https://doi.org/10.1017/ice.2021.284. [119] Derk, R. C., Coyle, J. P., Lindsley, W. G., Blachere, F. M., Lemons, A. R., Service, S. K., Martin, S. B., Mead, K. R., Fotta, S. A., Reynolds, J. S., McKinney, W. G., Sinsel, E. W., Beezhold, D. H., and Noti, J. D. Efficacy of Do-It-Yourself air filtration units in reducing exposure to simulated respiratory aerosols. [Online]. Building and Environment. 2023, 229, article no: 109920 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.109920. [120] Coyle, J. P., Derk, R. C., Lindsley, W. G., Blachere, F. M., Boots, T., Lemons, A. R., Martin, S. B., Mead, K. R., Fotta, S. A., Reynolds, J. S., McKinney, W. G., Sinsel, E. W., Beezhold, D. H., and Noti, J. D. Efficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room. [Online]. Viruses. 2021, 13(12), article no: 2536 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.3390/v13122536. [121] Fennelly, M., Hellebust, S., Wenger, J., O’Connor, D., Griffith, G. W., Plant, B. J., and Prentice, M. B. Portable HEPA filtration successfully augments natural-ventilation-mediated airborne particle clearance in a legacy design hospital ward. [Online]. Journal of Hospital Infection. 2023, 131, pp.54–57. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j. jhin.2022.09.017. [122] Rutala, W. A., Jones, S. M., Worthington, J. M., Reist, P. C., and Weber, D. J. Efficacy of portable filtration units in reducing aerosolized particles in the size range of Mycobacterium tuberculosis. [Online]. Infection Control and Hospital Epidemiology. 1995, 16(7), pp.391–398. [Accessed 17 March 2025]. Available from: https://doi.org/10.1086/647136. [123] Conway Morris, A., Sharrocks, K., Bousfield, R., Kermack, L., Maes, M., Higginson, E., Forrest, S., Pereira-Dias, J., Cormie, C., Old, T., Brooks, S., Hamed, I., Koenig, A., Turner, A., White, P., Floto, R. A., Dougan, G., Gkrania-Klotsas, E., Gouliouris, T., Baker, S., and Navapurkar, V. The Removal of Airborne Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) and Other Microbial Bioaerosols by Air Filtration on Coronavirus Disease 2019 (COVID-19) Surge Units. [Online]. Clinical Infectious Diseases.2022, 75(1), pp.e97–e101. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/cid/ciab933. [124] Thuresson, S., Fraenkel, C. J., Sasinovich, S., Soldemyr, J., Widell, A., Medstrand, P., Alsved, M., and Löndahl, J. Airborne Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Hospitals: Effects of Aerosol-Generating Procedures, HEPA-Filtration Units, Patient Viral Load, and Physical Distance. [Online]. Clinical Infectious Diseases. 2022, 75(1), pp.e89–e96. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/cid/ciac161. [125] Ueki, H., Ujie, M., Komori, Y., Kato, T., Imai, M., and Kawaoka, Y. Effectiveness of HEPA Filters at Removing Infectious SARS-CoV-2 from the Air. [Online]. mSphere. 2022, 7(4), article no: e0008622 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1128/msphere.00086-22. [126] Myers, N. T., Laumbach, R. J., Black, K. G., Ohman-Strickland, P., Alimokhtari, S., Legard, A., De Resende, A., Calderon, L., Lu, F. T., Mainelis, G., and Kipen, H. M. Portable air cleaners and residential exposure to SARS-CoV-2 aerosols: A real-world study. [Online]. Indoor Air. 2022, 32(4), article no: e13029 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/ina.13029. [127] Boswell, T. C. and Fox, P. C. Reduction in MRSA environmental contamination with a portable HEPA-filtration unit. [Online]. The Journal of Hospital Infection. 2006, 63(1), pp.47–54. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.jhin.2005.11.011. [128] Kowalski, W. UVGI Disinfection Theory. [Online]. Springer, 2009. [Accessed 26 February 2025]. Available from: https://doi.org/10.1007/978-3-642-01999-9_2. [129] Buonanno, M., Ponnaiya, B., Welch, D., Stanislauskas, M., Randers-Pehrson, G., Smilenov, L., Lowy, F. D., Owens, D. M., and Brenner, D. J. Germicidal Efficacy and Mammalian Skin Safety of 222-nm UV Light. [Online]. Radiation research. 2017, 187(4), pp.483–491. [Accessed 26 February 2025]. Available from: https://doi.org/10.1667/RR0010CC.1. [130] Tavares, R. S. N., Adamoski, D., Girasole, A., Lima, E. N., Silva Justo-Junior, A. da, Domingues, R., Silveira, A. C. C., Marques, R. E., Carvalho, M. de, Ambrosio, A. L. B., Leme, A. F. P., and Dias, S. M. G. Different biological effects of exposure to far-UVC (222 nm) and near-UVC (254 nm) irradiation. [Online]. Journal of Photochemistry and Photobiology B: Biology. 2023, 243, article no: 112713 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.jphotobiol.2023.112713. [131] Bueno de Mesquita, P. J., Sokas, R. K., Rice, M. B., and Nardell, E. A. FarUVC: Technology Update with an Untapped Potential to Mitigate Airborne Infections. [Online]. Annals of the American Thoracic Society. 2023, 20(12), pp.1700–1702. [Accessed 26 February 2025]. Available from: https://doi.org/10.1513/AnnalsATS.202305-460VP. [132] Eadie, E., Hiwar, W., Fletcher, L., Tidswell, E., O’Mahoney, P., Buonanno, M., Welch, D., Adamson, C. S., Brenner, D. J., Noakes, C., and Wood, K. Far-UVC (222 nm) efficiently inactivates an airborne pathogen in a room sized chamber. [Online]. Scientific Reports. 2022, 12(1), article no: 4373 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10. 1038/s41598-022-08462-z. [133] Welch, D., Buonanno, M., Grilj, V., Shuryak, I., Crickmore, C., Bigelow, A. W., Randers-Pehrson, G., Johnson, G. W., and Brenner, D. J. Far-UVC light: A new tool to control the spread of airborne-mediated microbial diseases. [Online]. Scientific Reports. 2018, 8(1), article no: 2752 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1038/s41598-018-21058-w. [134] Kitagawa, H., Nomura, T., Nazmul, T., Omori, K., Shigemoto, N., Sakaguchi, T., and Ohge, H. Effectiveness of 222-nm ultraviolet light on disinfecting SARS-CoV-2 surface contamination. [Online]. American Journal of Infection Control. 2021, 49(3), pp.299–301. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2020.08.022. [135] Kaple, C. E., Memic, S., Cadnum, J. L., and Donskey, C. J. Evaluation of an automated far ultraviolet-C light technology for decontamination of surfaces and aerosolized viruses in bathrooms. [Online]. Antimicrobial Resistance & Infection Control. 2024, 13(1), article no: 114 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1186/s13756-024-01473-7. [136] Bang, J.-I., Jo, Y.-L., Lee, E.-T., and Sung, M. Far-UVC (222 nm) disinfection performance in residential spaces: Experimental study on Bacillus subtilis contamination. [Online]. Results in Engineering. 2025, 25, article no: 103642 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.rineng.2024.103642. [137] Kitagawa, H., Kaiki, Y., Tadera, K., Nomura, T., Omori, K., Shigemoto, N., Takahashi, S., and Ohge, H. Pilot study on the decontamination efficacy of an installed 222-nm ultraviolet disinfection device (Care222™), with a motion sensor, in a shared bathroom. [Online]. Photodiagnosis and Photodynamic Therapy. 2021, 34, article no: 102334 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.pdpdt.2021.102334. 138] Browne, K. and Mitchell, B. G. Multimodal environmental cleaning strategies to prevent healthcare-associated infections. [Online]. Antimicrobial Resistance & Infection Control. 2023, 12(1), article no: 83 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1186/s13756-023-01274-4. [139] Donskey, C. J. Does improving surface cleaning and disinfection reduce healthcare-associated infections? [Online]. American Journal of Infection Control. 2013, 41(5), pp.S12–S19. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2012.12.010. [140] Sassi, H. P., Reynolds, K. A., Pepper, I. L., and Gerba, C. P. Evaluation of hospital-grade disinfectants on viral deposition on surfaces after toilet flushing. [Online]. American Journal of Infection Control. 2018, 46(5), pp.507–511. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2017.11.005. [141] Kollepara, P. K., Siegenfeld, A. F., Taleb, N. N., and Bar-Yam, Y. Unmasking the mask studies: why the effectiveness of surgical masks in preventing respiratory infections has been underestimated. [Online]. Journal of Travel Medicine. 2021, article no: taab144 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1093/jtm/taab144. [142] Das, S., Sarkar, S., Das, A., Das, S., Chakraborty, P., and Sarkar, J. A comprehensive review of various categories of face masks resistant to Covid19. [Online]. Clinical Epidemiology and Global Health. 2021, 12, article no: 100835 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10.1016/j.cegh.2021.100835. [143] MacIntyre, C. R. and Chughtai, A. A. A rapid systematic review of the efficacy of face masks and respirators against coronaviruses and other respiratory transmissible viruses for the community, healthcare workers and sick patients. [Online]. International Journal of Nursing Studies. 2020, 108, article no: 103629 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1016/j.ijnurstu.2020.103629. [144] Barasheed, O., Almasri, N., Badahdah, A.-M., Heron, L., Taylor, J., McPhee, K., Ridda, I., Haworth, E., Dwyer, D. E., and Rashid, H. Pilot Randomised Controlled Trial to Test Effectiveness of Facemasks in Preventing Influenza like Illness Transmission among Australian Hajj Pilgrims in 2011. [Online]. Infectious Disorders - Drug Targets. 2014, pp.110–116. [Accessed 25 February 2025]. Available from: https://doi.org/10.2174/1871526514666141021112855. [145] Canini, L., Andréoletti, L., Ferrari, P., D’Angelo, R., Blanchon, T., Lemaitre, M., Filleul, L., Ferry, J.-P., Desmaizieres, M., Smadja, S., Valleron, A.-J., and Carrat, F. Surgical Mask to Prevent Influenza Transmission in Households: A Cluster Randomized Trial. [Online]. PLOS ONE. 2010, 5(11), article no: e13998 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1371/journal.pone.0013998. [146] Johnson, D. F., Druce, J. D., Birch, C., and Grayson, M. L. A Quantitative Assessment of the Efficacy of Surgical and N95 Masks to Filter Influenza Virus in Patients with Acute Influenza Infection. [Online]. Clinical Infectious Diseases. 2009, 49(2), pp.275–277. [Accessed 25 February 2025]. Available from: https://doi.org/10.1086/600041. [147] MacIntyre, C. R., Zhang, Y., Chughtai, A. A., Seale, H., Zhang, D., Chu, Y., Zhang, H., Rahman, B., and Wang, Q. Cluster randomised controlled trial to examine medical mask use as source control for people with respiratory illness. [Online]. BMJ Open. 2016, 6(12), article no: e012330 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1136/bmjopen-2016-012330. [148] Liang, M., Gao, L., Cheng, C., Zhou, Q., Uy, J. P., Heiner, K., and Sun, C. Efficacy of face mask in preventing respiratory virus transmission: A systematic review and meta-analysis. [Online]. Travel Medicine and Infectious Disease. 2020, 36, article no: 101751 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.tmaid.2020.101751. [149] Jumaa, P. A. Hand hygiene: simple and complex. [Online]. International Journal of Infectious Diseases. 2005, 9(1), pp.3–14. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.ijid.2004.05.005. [150] Aiello, A. E., Coulborn, R. M., Perez, V., and Larson, E. L. Effect of Hand Hygiene on Infectious Disease Risk in the Community Setting: A Meta-Analysis. [Online]. American Journal of Public Health. 2008, 98(8), pp.1372–1381. [Accessed 26 February 2025]. Available from: https://doi.org/10.2105/AJPH.2007.124610. [151] Girou, E., Loyeau, S., Legrand, P., Oppein, F., and Brun-Buisson, C. Efficacy of handrubbing with alcohol based solution versus standard handwashing with antiseptic soap: randomised clinical trial. [Online]. BMJ. 2002, 325(7360), article no: 362 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1136/bmj.325.7360.362. [152] Mouajou, V., Adams, K., DeLisle, G., and Quach, C. Hand hygiene compliance in the prevention of hospital-acquired infections: a systematic review. [Online]. The Journal of Hospital Infection. 2022, 119, pp.33–48. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.jhin.2021.09.016. [153] Sickbert-Bennett, E. E., DiBiase, L. M., Willis, T. M. S., Wolak, E. S., Weber, D. J., and Rutala, W. A. Reduction of Healthcare-Associated Infections by Exceeding High Compliance with Hand Hygiene Practices. [Online]. Emerging Infectious Diseases. 2016, 22(9), pp.1628–1630. [Accessed 26 February 2025]. Available from: https://doi.org/10.3201/eid2209.151440. [154] Gammon, J., Hunt, J., Duffy, L., Humphreys, I., Hinkin, J., and Watkins, A. Impact of an educational intervention on hand hygiene practice among nursing students, with a focus on hand drying efficacy. [Online]. Journal of Infection Prevention. 2024, 25(1), pp.3–10. [Accessed 26 February 2025]. Available from: https://doi.org/10.1177/17571774231224695. [155] Carter, W. H. Flushed: How the Plumber Saved Civilization. [Online]. Atria Books, 2006. [Accessed 17 March 2025]. Available from: https://books.google.co.uk/books?id=QiGdMafoOUkC. [156] Allen, E. and Swoboda, D. How Buildings Work: The Natural Order of Architecture. [Online]. Oxford University Press, 2005. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/oso/9780195161984.001.0001. [157] Ritchie, L. Toilet. [Online]. 2012. [Accessed 26 February 2025]. Available from: https://flic.kr/p/cSuKFf. [158] Gugleta, L. Beautiful and modern bathroom seat. [Online]. 2019. [Accessed 27 February 2025]. Available from: https://unsplash.com/photos/whiteflush-toilet-8mMUnl_exqY. [159] Acabashi. City of London Cemetery and Crematorium permissive lavatory block cubicle 1. [Online]. 2020. [Accessed 26 February 2025]. Available from: https://flic.kr/p/2jhBHfu. [160] Beltz, G. Toilet. [Online]. 2017. [Accessed 26 February 2025]. Available from: https://flic.kr/p/TV7Czj. [161] Miller, D. K. Crazy Flushmate 2. [Online]. 2008. [Accessed 26 February 2025]. Available from: https://flic.kr/p/5faAve. [162] Kecko. Swiss SBB Train Toilet. [Online]. 2010. [Accessed 26 February 2025]. Available from: https://flic.kr/p/88Aiqw. [163] United States General Accounting Office. Water Infrastructure: Water-efficient Plumbing Fixtures Reduce Water Consumption and Wastewater Flows. [Online]. 2000. [Accessed 17 March 2025]. Available from: https://www.gao.gov/assets/rced-00-232.pdf. [164] U.S. Department of Housing and Urban Development. The Rehab Guide: Kitchens & baths. [Online]. 2000. [Accessed 17 March 2025]. Available from: https://books.google.co.uk/books?id=1r86ejmwQzQC. [165] United Nations Environment Programme. Every Drop Counts: Environmentally Sound Technologies for Urban and Domestic Water Use Efficiency. [Online]. 2008. [Accessed 17 March 2025]. Available from: http://digitallibrary.un.org/record/644388. [166] Li, Y.-Y., Wang, J.-X., and Chen, X. Can a toilet promote virus transmission? From a fluid dynamics perspective. [Online]. Physics of Fluids. 2020, 32(6), article no: 065107 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1063/5.0013318. [167] LaNasa, P. J. and Upp, E. L. Basic Flow Measurement Laws. In: LaNasa, P. J. and Upp, E. L., eds. Fluid Flow Measurement. [Online]. 2nd ed. Gulf Professional Publishing, 2002, pp.19–29. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/b978-0-12-409524-3.00002-2. [168] Rapp, B. E. Fluids. In: Rapp, B. E., ed. Microfluidics: Modelling, Mechanics and Mathematics. [Online]. Elsevier, 2017, pp.243–263. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/B978-1-4557-3141-1.50009-5. [169] Dandekar, R., Shen, N., Naar, B., and Bourouiba, L. Splash on a liquid pool: coupled cavity–sheet unsteady dynamics. [Online]. Journal of Fluid Mechanics. 2025, 1002, article no: A13 [no pagination]. [Accessed 27 February 2025]. Available from: https://doi.org/10.1017/jfm.2024.1105. [170] Zhang, H., Zhang, X., Yi, X., He, F., Niu, F., and Hao, P. Effect of wettability on droplet impact: Spreading and splashing. [Online]. Experimental Thermal and Fluid Science. 2021, 124, article no: 110369 [no pagination]. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/j.expthermflusci.2021.110369. [171] Zhang, H., Su, X., Xiao, Q., and Lai, A. C. K. Experimental study on droplet and bioaerosol emissions from flushing a squat toilet. [Online]. Building and Environment. 2024, 250, p.v. [Accessed 21 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2024.111162. [172] Macher, J. M. Positive-hole correction of multiple-jet impactors for collecting viable microorganisms. [Online]. American Industrial Hygiene Association Journal. 1989, 50(11), pp.561–568. [Accessed 17 March 2025]. Available from: https://doi.org/10.1080/15298668991375164. [173] Halkman, H. B. D. and Halkman, A. K. Indicator Organisms. In: Batt, C. A. and Tortorello, M. L., eds. Encyclopedia of Food Microbiology. [Online]. 2nd ed. Academic Press, 2014, pp.358–363. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/B978-0-12-384730-0.00396-7. [174] Eden, R. ENTEROBACTERIACEAE, COLIFORMS AND E. COLI | Classical and Modern Methods for Detection and Enumeration. In: Batt, C. A. and Tortorello, M. L., eds. Encyclopedia of Food Microbiology. [Online]. 2nd ed. Academic Press, 2014, pp.667–673. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/B978-0-12-384730-0.00097-5. [175] Price, R. G., Wildeboer, D., Price, R. G., and Wildeboer, D. E. coli as an Indicator of Contamination and Health Risk in Environmental Waters. In: Escherichia coli – Recent Advances on Physiology, Pathogenesis and Biotechnological Applications. [Online]. InTech, 2017. [Accessed 27 February 2025]. Available from: https://doi.org/10.5772/67330. [176] Holcomb, D. A. and Stewart, J. R. Microbial Indicators of Fecal Pollution: Recent Progress and Challenges in Assessing Water Quality. [Online]. Current Environmental Health Reports. 2020, 7(3), pp.311–324. [Accessed 27 February 2025]. Available from: https://doi.org/10.1007/s40572-020-00278-1. [177] Riemann, H. and Cliver, D. O. Foodborne Infections and Intoxications. [Online]. 2011. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/B978-0-12-416041-5.00037-8. [178] Im, J., Nichols, C., Bjerregaard-Andersen, M., Sow, A. G., Løfberg, S., Tall, A., Pak, G. D., Aaby, P., Baker, S., Clemens, J. D., Espinoza, L. M. C., Konings, F., May, J., Monteiro, M., Niang, A., Panzner, U., Park, S. E., Schütt-Gerowitt, H., Wierzba, T. F., Marks, F., and Kalckreuth, V. von. Prevalence of Salmonella Excretion in Stool: A Community Survey in 2 Sites, Guinea-Bissau and Senegal. [Online]. Clinical Infectious Diseases. 2016, 62, pp.S50–S55. [Accessed 27 February 2025]. Available from: https://doi.org/10.1093/cid/civ789. [179] Hale, T. L. and Keusch, G. T. Medical Microbiology. [Online]. 4th ed. University of Texas Medical Branch at Galveston, 1996. [Accessed 27 February 2025]. Available from: https://www.ncbi.nlm.nih.gov/books/NBK7627/. [180] Guh, A. Y. and Kutty, P. K. Clostridioides difficile Infection. [Online]. Annals of Internal Medicine. 2018, 169(7), pp.ITC49–ITC64. [Accessed 27 February 2025]. Available from: https://doi.org/10.7326/AITC201810020. [181] Lee, N., Chan, M. C. W., Wong, B., Choi, K. W., Sin, W., Lui, G., Chan, R. C. W., Lai, R. W. M., Cockram, C. S., Sung, J. J. Y., and Leung, W. K. Fecal Viral Concentration and Diarrhea in Norovirus Gastroenteritis. [Online]. Emerging Infectious Diseases. 2007, 13(9), pp.1399–1401. [Accessed 25 January 2024]. Available from: https://doi.org/10.3201/eid1309.061535. [182] Brown, D. M., Butler, D., Orman, N. R., and Davies, J. W. Gross solids transport in small diameter sewers. [Online]. Water Science and Technology. 1996, 33(9), pp.25–30. [Accessed 26 January 2024]. Available from: https://doi.org/10.1016/0273-1223(96)00366-6. [183] Flewett, T. H. Rotavirus in the home and hospital nursery. [Online]. British Medical Journal (Clinical Research Ed.) 1983, 287(6392), pp.568–569. [Accessed 17 March 2025]. Available from: https://doi.org/10.1136/bmj.287.6392.568. [184] Dennehy, P. H. Transmission of rotavirus and other enteric pathogens in the home. [Online]. The Pediatric Infectious Disease Journal. 2000, 19(10), S103–S105. [Accessed 27 February 2025]. Available from: https://doi.org/10.1097/00006454-200010001-00003. [185] Zhu, N., Zhang, D., Wang, W., Li, X., Yang, B., Song, J., Zhao, X., Huang, B., Shi, W., Lu, R., Niu, P., Zhan, F., Ma, X., Wang, D., Xu, W., Wu, G., Gao, G. F., and Tan, W. A Novel Coronavirus from Patients with Pneumonia in China, 2019. [Online]. New England Journal of Medicine. 2020, 382(8), pp.727–733. [Accessed 15 January 2025]. Available from: https://doi.org/10.1056/NEJMoa2001017. [186] Foladori, P., Cutrupi, F., Segata, N., Manara, S., Pinto, F., Malpei, F., Bruni, L., and La Rosa, G. SARS-CoV-2 from faeces to wastewater treatment: What do we know? A review. [Online]. Science of The Total Environment. 2020, 743, article no: 140444 [no pagination]. [Accessed 23 January 2024]. Available from: https://doi.org/10.1016/j.scitotenv.2020.140444. [187] Dada, A. C. and Gyawali, P. Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants. [Online]. Science of The Total Environment. 2021, 763, article no: 142989 [no pagination]. [Accessed 12 January 2024]. Available from: https://doi.org/10.1016/j.scitotenv.2020.142989. [188] Barroso-Arévalo, S., Rivera, B., Domínguez, L., and Sánchez-Vizcaíno, J. M. First Detection of SARS-CoV-2 B.1.1.7 Variant of Concern in an Asymptomatic Dog in Spain. [Online]. Viruses. 2021, 13(7), article no: 1379 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.3390/v13071379. [189] Gortázar, C., Barroso-Arévalo, S., Ferreras-Colino, E., Isla, J., Fuente, G. d. l., Rivera, B., Domínguez, L., Fuente, J. d. l., and Sánchez-Vizcaíno, J. M. Natural SARS-CoV-2 Infection in Kept Ferrets, Spain. [Online]. Emerging Infectious Diseases. 2021, 27(7), article no: 1994 [no pagination]. [Accessed 19 November 2024]. Available from: https://doi.org/10.3201/eid2707.210096. [190] Dergham, J., Delerce, J., Bedotto, M., La Scola, B., and Moal, V. Isolation of Viable SARS-CoV-2 Virus from Feces of an Immunocompromised Patient Suggesting a Possible Fecal Mode of Transmission. [Online]. Journal of Clinical Medicine. 2021, 10(12), article no: 2696 [no pagination]. [Accessed 19 November 2024]. Available from: https://doi.org/10.3390/jcm10122696. [191] Zhou, J., Li, C., Liu, X., Chiu, M. C., Zhao, X., Wang, D., Wei, Y., Lee, A., Zhang, A. J., Chu, H., Cai, J.-P., Yip, C. C.-Y., Chan, I. H.-Y., Wong, K. K.-Y., Tsang, O. T.-Y., Chan, K.-H., Chan, J. F.-W., To, K. K.-W., Chen, H., and Yuen, K. Y. Infection of bat and human intestinal organoids by SARS-CoV-2. [Online]. Nature Medicine. 2020, 26(7), pp.1077–1083. [Accessed 17 March 2025]. Available from: https://doi.org/10.1038/s41591-020-0912-6. [192] Yao, H., Lu, X., Chen, Q., Xu, K., Chen, Y., Cheng, L., Liu, F., Wu, Z., Wu, H., Jin, C., Zheng, M., Wu, N., Jiang, C., and Li, L. Patient-derived mutations impact pathogenicity of SARS-CoV-2. [Online]. 2020. [Accessed 19 November 2024]. Available from: https://doi.org/10.1101/2020.04.14.20060160. [193] Das Adhikari, U., Eng, G., Farcasanu, M., Avena, L. E., Choudhary, M. C., Triant, V. A., Flagg, M., Schiff, A. E., Gomez, I., Froehle, L. M., Diefenbach, T. J., Ronsard, L., Lingwood, D., Lee, G. C., Rabi, S. A., Erstad, D., Velmahos, G., Li, J. Z., Hodin, R., Stone, J. R., Honko, A. N., Griffiths, A., Yilmaz, Ö. H., and Kwon, D. S. Fecal Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-Cov-2) RNA Is Associated With Decreased Coronavirus Disease 2019 (COVID-19) Survival. [Online]. Clinical Infectious Diseases. 2022, 74(6), pp.1081–1084. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/cid/ciab623. [194] Audsley, J. M., Holmes, N. E., Mordant, F. L., Douros, C., Zufan, S. E., Nguyen, T. H. O., Kedzierski, L., Rowntree, L. C., Hensen, L., Subbarao, K., Kedzierska, K., Nicholson, S., Sherry, N., Thevarajan, I., Tran, T., and Druce, J. Temporal differences in culturable severe acute respiratory coronavirus virus 2 (SARS-CoV-2) from the respiratory and gastrointestinal tracts in a patient with moderate coronavirus disease 2019 (COVID-19). [Online]. Infection Control and Hospital Epidemiology. 2022, 43(9), pp.1286–1288. [Accessed 17 March 2025]. Available from: https://doi.org/10.1017/ice.2021.223. [195] Jeong, H. W., Kim, S.-M., Kim, H.-S., Kim, Y.-I., Kim, J. H., Cho, J. Y., Kim, S.-h., Kang, H., Kim, S.-G., Park, S.-J., Kim, E.-H., and Choi, Y. K. Viable SARS-CoV-2 in various specimens from COVID-19 patients. [Online]. Clinical Microbiology and Infection. 2020, 26(11), pp.1520–1524. [Accessed 19 November 2024]. Available from: https://doi.org/10.1016/j.cmi.2020.07.020. [196] Jiao, L., Li, H., Xu, J., Yang, M., Ma, C., Li, J., Zhao, S., Wang, H., Yang, Y., Yu, W., Wang, J., Yang, J., Long, H., Gao, J., Ding, K., Wu, D., Kuang, D., Zhao, Y., Liu, J., Lu, S., Liu, H., and Peng, X. The Gastrointestinal Tract Is an Alternative Route for SARS-CoV-2 Infection in a Nonhuman Primate Model. [Online]. Gastroenterology. 2021, 160(5), pp.1647–1661. [Accessed 17 March 2025]. Available from: https://doi.org/10.1053/j.gastro.2020.12.001. [197] Xiao, F., Sun, J., Xu, Y., Li, F., Huang, X., Li, H., Zhao, J., Huang, J., and Zhao, J. Infectious SARS-CoV-2 in Feces of Patient with Severe COVID-19. [Online]. Emerging Infectious Diseases. 2020, 26(8), pp.1920–1922. [Accessed 17 March 2025]. Available from: https://doi.org/10.3201/eid2608.200681. [198] Bartlett, S. L., Diel, D. G., Wang, L., Zec, S., Laverack, M., Martins, M., Caserta, L. C., Killian, M. L., Terio, K., Olmstead, C., Delaney, M. A., Stokol, T., Ivančić, M., Jenkins-Moore, M., Ingerman, K., Teegan, T., McCann, C., Thomas, P., McAloose, D., Sykes, J. M., and Calle, P. P. SARS-CoV-2 Infection And Longitudinal Fecal Screening In Malayan Tigers (Panthera tigris jacksoni), Amur Tigers (Panthera tigris altaica), And African Lions (Panthera leo krugeri) At The Bronx Zoo, New York, USA. [Online]. Journal of Zoo and Wildlife Medicine. 2021, 51(4), pp.733–744. [Accessed 17 March 2025]. Available from: https://doi.org/10.1638/2020-0171. [199] Wang, W., Xu, Y., Gao, R., Lu, R., Han, K., Wu, G., and Tan, W. Detection of SARS-CoV-2 in Different Types of Clinical Specimens. [Online]. JAMA. 2020, 323(18), article no: 1843 [no pagination]. [Accessed 19 November 2024]. Available from: https://doi.org/10.1001/jama.2020.3786. [200] Zhang, Y., Chen, C., Song, Y., Zhu, S., Wang, D., Zhang, H., Han, G., Weng, Y., Xu, J., Xu, J., Yu, P., Jiang, W., Yang, X., Lang, Z., Yan, D., Wang, Y., Song, J., Gao, G. F., Wu, G., and Xu, W. Excretion of SARS-CoV-2 through faecal specimens. [Online]. Emerging Microbes & Infections. 2020, 9(1), pp.2501–2508. [Accessed 17 March 2025]. Available from: https://doi.org/10.1080/22221751.2020.1844551. [201] Riley, E. C., Murphy, G., and Riley, R. L. Airborne spread of measles in a suburban elementary school. [Online]. American Journal of Epidemiology. 1978, 107(5), pp.421–432. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/oxfordjournals.aje.a112560. [202] Buonanno, G., Stabile, L., and Morawska, L. Estimation of airborne viral emission: Quanta emission rate of SARS-CoV-2 for infection risk assessment. [Online]. Environment International. 2020, 141, article no: 105794 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10. 1016/j.envint.2020.105794. [203] Noakes, C. J. and Sleigh, A., Applying the Wells-Riley equation to the risk of airborne infection in hospital environments: The importance of stochastic and proximity effects. In: Indoor Air 2008: the 11th International Conference on Indoor Air Quality and Climate, 17 - 18 August 2008, Copenhagen. [Online]. ISIAQ, 2008, pp.161–168. [Accessed 15 March 2025]. Available from: https://eprints.whiterose.ac.uk/7702/1/Noakes-indoorair2008.pdf. [204] Edwards, A. J., King, M.-F., Noakes, C. J., Peckham, D., and López-García, M. The Wells–Riley model revisited: Randomness, heterogeneity, and transient behaviours. [Online]. Risk Analysis. 2024, 44(9), pp.2125–2147. [Accessed 28 February 2025]. Available from: https://doi.org/10.1111/risa.14295. [205] Gammaitoni, L. and Nucci, M. C. Using a mathematical model to evaluate the efficacy of TB control measures. [Online]. Emerging Infectious Diseases. 1997, 3(3), pp.335–342. [Accessed 28 February 2025]. Available from: https://doi.org/10.3201/eid0303.970310. [206] Nardell, E. A., Keegan, J., Cheney, S. A., and Etkind, S. C. Airborne infection. Theoretical limits of protection achievable by building ventilation. [Online]. The American Review of Respiratory Disease. 1991, 144(2), pp.302–306. [Accessed 17 March 2025]. Available from: https://doi.org/10.1164/ajrccm/144.2.302. [207] Escombe, A. R., Oeser, C. C., Gilman, R. H., Navincopa, M., Ticona, E., Pan, W., Martínez, C., Chacaltana, J., Rodríguez, R., Moore, D. A. J., Friedland, J. S., and Evans, C. A. Natural Ventilation for the Prevention of Airborne Contagion. [Online]. PLOS Medicine. 2007, 4(2), article no: e68 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1371/journal.pmed.0040068. [208] Gao, N. P., Niu, J. L., Perino, M., and Heiselberg, P. The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation. [Online]. Building and Environment. 2008, 43(11), pp.1805–1817. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2007.10.023. [209] Qian, H., Li, Y., Nielsen, P. V., and Huang, X. Spatial distribution of infection risk of SARS transmission in a hospital ward. [Online]. Building and Environment. 2009, 44(8), pp.1651–1658. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2008.11.002. [210] Tung, Y.-C. and Hu, S.-C. Infection Risk of Indoor Airborne Transmission of Diseases in Multiple Spaces. [Online]. Architectural Science Review. 2008, 51(1), pp.14–20. [Accessed 28 February 2025]. Available from: https://doi.org/10.3763/asre.2008.5103. [211] Wang, Z., Galea, E. R., Grandison, A., Ewer, J., and Jia, F. A coupled Computational Fluid Dynamics and Wells-Riley model to predict COVID-19 infection probability for passengers on long-distance trains. [Online]. Safety Science. 2022, 147, article no: 105572 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.ssci.2021.105572. [212] Pantelic, J. and Tham, K. W. Assessment of the mixing air delivery system ability to protect occupants from the airborne infectious disease transmission using Wells–Riley approach. [Online]. HVAC&R Research. 2012, 18(4), pp.562–574. [Accessed 28 February 2025]. Available from: https://doi.org/10.1080/10789669.2012.647230. [213] Guo, Y., Qian, H., Sun, Z., Cao, J., Liu, F., Luo, X., Ling, R., Weschler, L. B., Mo, J., and Zhang, Y. Assessing and controlling infection risk with Wells-Riley model and spatial flow impact factor (SFIF). [Online]. Sustainable Cities and Society. 2021, 67, article no: 102719 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.scs.2021.102719. [214] Lau, Z., Griffiths, I. M., English, A., and Kaouri, K. Predicting the spatiotemporal infection risk in indoor spaces using an efficient airborne transmission model. [Online]. Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences. 2022, 478(2259), article no: 20210383 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1098/rspa.2021.0383. [215] Ding, S., Lee, J. S., Mohamed, M. A., and Ng, B. F. Infection risk of SARSCoV-2 in a dining setting: Deposited droplets and aerosols. [Online]. Building and Environment. 2022, 213, article no: 108888 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.108888. [216] Li, J., Cheng, Z., Zhang, Y., Mao, N., Guo, S., Wang, Q., Zhao, L., and Long, E. Evaluation of infection risk for SARS-CoV-2 transmission on university campuses. [Online]. Science and Technology for the Built Environment. 2021, 27(9), pp.1165–1180. [Accessed 28 February 2025]. Available from: https://doi.org/10.1080/23744731.2021.1948762. [217] Li, H., Shankar, S. N., Witanachchi, C. T., Lednicky, J. A., Loeb, J. C., Alam, M. M., Fan, Z. H., Mohamed, K., Eiguren-Fernandez, A., and Wu, C.-Y. Environmental Surveillance and Transmission Risk Assessments for SARS-CoV-2 in a Fitness Center. [Online]. Aerosol and Air Quality Research. 2021, 21(11), article no: 210106 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.4209/aaqr.210106. [218] Timpitak, W. and Pochai, N. A Mathematical Model of Risk Assessment on Airborne Infection in a Room with an Outlet Ventilation System. [Online]. Engineering Letters. 2022, 30(2). [Accessed 19 January 2025]. Available from: https://www.engineeringletters.com/issues_v30/issue_2/EL_30_2_56.pdf. [219] Boonmeemapasuk, W. and Pochai, N. A Risk Model of Airborne Transmission and Vaccine Efficacy in an Outpatient Room with a Ventilation System. [Online]. Engineering Letters. 2022, 30(2). [Accessed 17 March 2025]. Available from: https://www.engineeringletters.com/issues_v30/issue_2/EL_30_2_28.pdf. [220] Wood, S. G. A., Craske, J., and Burridge, H. C. Relating quanta conservation and compartmental epidemiological models of airborne disease outbreaks in buildings. [Online]. Scientific Reports. 2023, 13(1), article no: 17335 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1038/s41598-023-44527-3. [221] Haas, C. N., Rose, J. B., and Gerba, C. P. Quantitative Microbial Risk Assessment. [Online]. Wiley, 1999. [Accessed 18 March 2025]. Available from: https://books.google.co.uk/books?id=vjVhhwQh9N8C. [222] Rose, J. B., Haas, C. N., and Regli, S. Risk assessment and control of waterborne giardiasis. [Online]. American Journal of Public Health. 1991, 81(6), pp.709–713. [Accessed 28 February 2025]. Available from: https://doi.org/10.2105/ajph.81.6.709. [223] Schmid-Hempel, P. Immune defence, parasite evasion strategies and their relevance for ‘macroscopic phenomena’ such as virulence. [Online]. Philosophical Transactions of the Royal Society B: Biological Sciences. 2009, 364(1513), pp.85–98. [Accessed 28 February 2025]. Available from: https://doi.org/10.1098/rstb.2008.0157. [224] Haas, C. N. Estimation of risk due to low doses of microorganisms: a comparison of alternative methodologies. [Online]. American Journal of Epidemiology. 1983, 118(4), pp.573–582. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/oxfordjournals.aje.a113662. [225] Sze To, G. N. and Chao, C. Y. H. Review and comparison between the Wells-Riley and dose-response approaches to risk assessment of infectious respiratory diseases. [Online]. Indoor Air. 2010, 20(1), pp.2–16. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/j.1600-0668.2009.00621.x. [226] Williams, M. S., Baker, M. R., Guina, T., Hewitt, J. A., Lanning, L., Hill, H., May, J. M., Fogtman, B., and Pittman, P. R. Retrospective Analysis of Pneumonic Tularemia in Operation Whitecoat Human Subjects: Disease Progression and Tetracycline Efficacy. [Online]. Frontiers in Medicine. 2019, 6, article no: 229 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10.3389/fmed.2019.00229. [227] Killingley, B., Mann, A. J., Kalinova, M., Boyers, A., Goonawardane, N., Zhou, J., Lindsell, K., Hare, S. S., Brown, J., Frise, R., Smith, E., Hopkins, C., Noulin, N., Löndt, B., Wilkinson, T., Harden, S., McShane, H., Baillet, M., Gilbert, A., Jacobs, M., Charman, C., Mande, P., Nguyen-Van-Tam, J. S., Semple, M. G., Read, R. C., Ferguson, N. M., Openshaw, P. J., Rapeport, G., Barclay, W. S., Catchpole, A. P., and Chiu, C. Safety, tolerability and viral kinetics during SARS-CoV-2 human challenge in young adults. [Online]. Nature Medicine. 2022, 28(5), pp.1031–1041. [Accessed 15 January 2025]. Available from: https://doi.org/10.1038/s41591-022-01780-9. [228] McCullogh, N. B. and Eisele, C. W. Experimental human salmonellosis. I. Pathogenicity of strains of Salmonella meleagridis and Salmonella anatum obtained from spray-dried whole egg. [Online]. The Journal of Infectious Diseases. 1951, 88(3), pp.278–289. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/infdis/88.3.278. [229] DuPont, H. L., Hornick, R. B., Dawkins, A. T., Snyder, M. J., and Formal, S. B. The Response of Man to Virulent Shigella flexneri 2a. [Online]. The Journal of Infectious Diseases. 1969, 119(3), pp.296–299. [Accessed 3 March 2025]. Available from: https://doi.org/10.1093/infdis/119.3.296. [230] Ward, R. L., Bernstein, D. I., Young, E. C., Sherwood, J. R., Knowlton, D. R., and Schiff, G. M. Human rotavirus studies in volunteers: determination of infectious dose and serological response to infection. [Online]. The Journal of Infectious Diseases. 1986, 154(5), pp.871–880. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/infdis/154.5.871. [231] Zhang, X. and Wang, J. Dose-response Relation Deduced for Coronaviruses From Coronavirus Disease 2019, Severe Acute Respiratory Syndrome, and Middle East Respiratory Syndrome: Meta-analysis Results and its Application for Infection Risk Assessment of Aerosol Transmission. [Online]. Clinical Infectious Diseases. 2021, 73(1), pp.e241–e245. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/cid/ciaa1675. [232] Dediego, M. L., Pewe, L., Alvarez, E., Rejas, M. T., Perlman, S., and Enjuanes, L. Pathogenicity of severe acute respiratory coronavirus deletion mutants in hACE-2 transgenic mice. [Online]. Virology. 2008, 376(2), pp.379–389. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.virol.2008.03.005. [233] Koprowski, H. Immunization against poliomyelitis with living attenuated virus. [Online]. The American Journal of Tropical Medicine and Hygiene. 1956, 5(3), pp.440–452. [Accessed 17 March 2025]. Available from: https://doi.org/10.4269/ajtmh.1956.5.440. [234] Cliver, D. O. Experimental Infection by Waterborne Enteroviruses. [Online]. Journal of Food Protection. 1981, 44(11), pp.861–865. [Accessed 17 March 2025]. Available from: https://doi.org/10.4315/0362-028X-44.11.861. [235] Toth, D. J. A., Gundlapalli, A. V., Schell, W. A., Bulmahn, K., Walton, T. E., Woods, C. W., Coghill, C., Gallegos, F., Samore, M. H., and Adler, F. R. Quantitative models of the dose-response and time course of inhalational anthrax in humans. [Online]. PLoS pathogens. 2013, 9(8), article no: e1003555 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1371/journal.ppat.1003555. [236] Murphy, B. R., Clements, M. L., Madore, H. P., Steinberg, J., O’Donnell, S., Betts, R., Demico, D., Reichman, R. C., Dolin, R., and Maassab, H. F. Dose Response of Cold-Adapted, Reassortant Influenza A/California/10/78 Virus (H1N1) in Adult Volunteers. [Online]. The Journal of Infectious Diseases. 1984, 149(5), p.816. [Accessed 15 January 2025]. Available from: https://doi.org/10.1093/infdis/149.5.816. [237] Hendley, J. O., Edmondson, W. P., and Gwaltney, J. M. Relation between naturally acquired immunity and infectivity of two rhinoviruses in volunteers. [Online]. The Journal of Infectious Diseases. 1972, 125(3), pp.243–248. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/infdis/125.3.243. [238] DuPont, H. L., Formal, S. B., Hornick, R. B., Snyder, M. J., Libonati, J. P., Sheahan, D. G., LaBrec, E. H., and Kalas, J. P. Pathogenesis of Escherichia coli diarrhea. [Online]. The New England Journal of Medicine. 1971, 285(1), pp.1–9. [Accessed 17 March 2025]. Available from: https://doi.org/10.1056/NEJM197107012850101. [239] Allen, L. J. S. An introduction to stochastic processes with applications to biology. [Online]. 2nd ed. CRC Press, 2003. [Accessed 15 January 2025]. Available from: https://doi.org/10.1201/b12537. [240] King, M.-F., Noakes, C. J., and Sleigh, P. A. Modeling environmental contamination in hospital single- and four-bed rooms. [Online]. Indoor Air. 2015, 25(6), pp.694–707. [Accessed 15 January 2025]. Available from: https://doi.org/10.1111/ina.12186. [241] Pessoa-Silva, C. L., Dharan, S., Hugonnet, S., Touveneau, S., Posfay-Barbe, K., Pfister, R., and Pittet, D. Dynamics of bacterial hand contamination during routine neonatal care. [Online]. Infection Control and Hospital Epidemiology. 2004, 25(3), pp.192–197. [Accessed 17 March 2025]. Available from: https://doi.org/10.1086/502376. [242] Wilson, A. M., Mussio, I., Verhougstraete, M. P., Jung, Y., Ashraf, A., Chilton, S., and Hamilton, K. A. A risk-risk tradeoff approach for incorporating the public’s risk perceptions into quantitative microbial risk assessment. [Online]. Journal of Occupational and Environmental Hygiene. 2025, 0(0), pp.1–17. [Accessed 20 January 2025]. Available from: https://doi.org/10.1080/15459624.2024.2423756. [243] Environmental Protection Agency (EPA). National primary drinking water regulations: Long Term 1 Enhanced Surface Water Treatment Rule. Final rule. [Online]. Federal Register. 2002, 67(9), pp.1811–1844. [Accessed 17 March 2025]. Available from: https://www.federalregister.gov/d/02-409. [244] Reynolds, K. A., Verhougstraete, M. P., Mena, K. D., Sattar, S. A., Scott, E. A., and Gerba, C. P. Quantifying pathogen infection risks from household laundry practices. [Online]. Journal of Applied Microbiology. 2022, 132(2), pp.1435–1448. [Accessed 20 January 2025]. Available from: https://doi.org/10.1111/jam.15273. [245] Ryan, M. O., Haas, C. N., Gurian, P. L., Gerba, C. P., Panzl, B. M., and Rose, J. B. Application of quantitative microbial risk assessment for selection of microbial reduction targets for hard surface disinfectants. [Online]. American Journal of Infection Control. 2014, 42(11), pp.1165–1172. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2014.07.024. [246] King, M.-F., Wilson, A. M., Weir, M. H., López-García, M., Proctor, J., Hiwar, W., Khan, A., Fletcher, L. A., Sleigh, P. A., Clifton, I., Dancer, S. J., Wilcox, M., Reynolds, K. A., and Noakes, C. J. Modeling fomite-mediated SARS-CoV-2 exposure through personal protective equipment doffing in a hospital environment. [Online]. Indoor Air. 2022, 32(1), article no: e12938 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/ina.12938. [247] Mizukoshi, A., Nakama, C., Okumura, J., and Azuma, K. Assessing the risk of COVID-19 from multiple pathways of exposure to SARS-CoV-2: Modeling in health-care settings and effectiveness of nonpharmaceutical interventions. [Online]. Environment International. 2021, 147, article no: 106338 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.envint.2020.106338. [248] Schijven, J. F., Wind, M., Todt, D., Howes, J., Tamele, B., and Steinmann, E. Risk assessment of banknotes as a fomite of SARS-CoV-2 in cash payment transactions. [Online]. Risk Analysis. 2023, 43(4), pp.700–708. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/risa.13935. [249] Zhang, X., Wu, J., Smith, L. M., Li, X., Yancey, O., Franzblau, A., Dvonch, J. T., Xi, C., and Neitzel, R. L. Monitoring SARS-CoV-2 in air and on surfaces and estimating infection risk in buildings and buses on a university campus. [Online]. Journal of Exposure Science & Environmental Epidemiology. 2022, 32(5), pp.751–758. [Accessed 1 March 2025]. Available from: https://doi.org/10.1038/s41370-022-00442-9. [250] Bate, A. M., Miller, D., King, M.-F., Moseley, K.-A., Xu, J., Hall, I., López-García, M., Parker, S. T., and Noakes, C. J. A quantitative microbial risk assessment approach to estimate exposure to SARS-CoV-2 on a bus. [Online]. Journal of Transport & Health. 2024, 38, article no: 101829 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.jth.2024.101829. [251] Wilson, A. M., Reynolds, K. A., Sexton, J. D., and Canales, R. A. Modeling Surface Disinfection Needs To Meet Microbial Risk Reduction Targets. [Online]. Applied and Environmental Microbiology. 2018, 84(18), article no: e00709–18 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1128/AEM.00709-18. [252] Wilson, A. M., Reynolds, K. A., and Canales, R. A. Estimating the effect of hand hygiene compliance and surface cleaning timing on infection risk reductions with a mathematical modeling approach. [Online]. American Journal of Infection Control. 2019, 47(12), pp.1453–1459. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2019.05.023. [253] Wilson, A. M., King, M.-F., López-García, M., Clifton, I. J., Proctor, J., Reynolds, K. A., and Noakes, C. J. Effects of patient room layout on viral accruement on healthcare professionals’ hands. [Online]. Indoor Air. 2021, 31(5), pp.1657–1672. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/ina.12834. [254] Armstrong, T. W. and Haas, C. N. A Quantitative Microbial Risk Assessment Model for Legionnaires’ Disease: Animal Model Selection and Dose Response Modeling. [Online]. Risk Analysis. 2007, 27(6), pp.1581–1596. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/j.1539-6924.2007.00990.x. [255] Madera-García, V., Mraz, A. L., Lopez-Galvez, N., Weir, M. H., Werner, J., Beamer, P. I., and Verhougstraete, M. P. Legionella pneumophila as a Health Hazard to Miners: A Pilot Study of Water Quality and QMRA. [Online]. Water. 2019, 11(8), article no: 1528 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.3390/w11081528. [256] Pepper, I. L. and Gerba, C. P. Risk of infection from Legionella associated with spray irrigation of reclaimed water. [Online]. Water Research. 2018, 139, pp.101–107. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.watres.2018.04.001. [257] Xu, P.-C., Zhang, C.-M., and Wang, X. C. Numerical simulation for spatial distribution of water aerosol produced from nozzle spray and health risk related to Legionella pneumophila in spray scenarios. [Online]. Water Research. 2022, 216, article no: 118304 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.watres.2022.118304. [258] Hamilton, K. A., Kuppravalli, A., Heida, A., Joshi, S., Haas, C. N., Verhougstraete, M., and Gerrity, D. Legionnaires’ disease in dental offices: Quantifying aerosol risks to dental workers and patients. [Online]. Journal of Occupational and Environmental Hygiene. 2021, 18(8), pp.378–393. [Accessed 1 March 2025]. Available from: https://doi.org/10.1080/15459624.2021.1939878. [259] Hamilton, K. A., Hamilton, M. T., Johnson, W., Jjemba, P., Bukhari, Z., LeChevallier, M., and Haas, C. N. Health risks from exposure to Legionella in reclaimed water aerosols: Toilet flushing, spray irrigation, and cooling towers. [Online]. Water Research. 2018, 134, pp.261–279. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.watres.2017.12.022. [260] Hamilton, K. A., Hamilton, M. T., Johnson, W., Jjemba, P., Bukhari, Z., LeChevallier, M., Haas, C. N., and Gurian, P. L. Risk-Based Critical Concentrations of Legionella pneumophila for Indoor Residential Water Uses. [Online]. Environmental Science & Technology. 2019, 53(8), pp.4528–4541. [Accessed 17 March 2025]. Available from: https://doi.org/10.1021/acs.est.8b03000. [261] Ahmed, W., Vieritz, A., Goonetilleke, A., and Gardner, T. Health risk from the use of roof-harvested rainwater in Southeast Queensland, Australia, as potable or nonpotable water, determined using quantitative microbial risk assessment. [Online]. Applied and Environmental Microbiology. 2010, 76(22), pp.7382–7391. [Accessed 17 March 2025]. Available from: https://doi.org/10.1128/AEM.00944-10. [262] Blanky, M., Sharaby, Y., Rodríguez-Martínez, S., Halpern, M., and Friedler, E. Greywater reuse - Assessment of the health risk induced by Legionella pneumophila. [Online]. Water Research. 2017, 125, pp.410–417. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.watres.2017. 08.068. [263] Bouwknegt, M., Schijven, J. F., Schalk, J. A. C., and Roda Husman, A. M. de. Quantitative risk estimation for a Legionella pneumophila infection due to whirlpool use. [Online]. Risk Analysis. 2013, 33(7), pp.1228–1236. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/j.1539-6924.2012.01909.x. [264] Chen, M., Shi, L., Liu, G., Wu, X., and Lu, Y. Aerosol exposure assessment during reclaimed water utilization in China and risk evaluation in case of Legionella. [Online]. Frontiers of Environmental Science & Engineering. 2021, 16(7), article no: 95 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1007/s11783-021-1516-1. [265] Kusumawardhana, A., Zlatanovic, L., Bosch, A., and Hoek, J. P. van der. Microbiological Health Risk Assessment of Water Conservation Strategies: A Case Study in Amsterdam. [Online]. International Journal of Environmental Research and Public Health. 2021, 18(5), article no: 2595 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.3390/ijerph18052595. [266] Massiot, G., Courault, D., Jacob, P., and Albert, I. Monitoring the risk of Legionella infection using a general Bayesian network updated from temporal measurements in agricultural irrigation with reclaimed wastewater. [Online]. Environmental Science: Water Research & Technology. 2022, 9(1), pp.176–192. [Accessed 1 March 2025]. Available from: https://doi.org/10.1039/D2EW00311B. [267] Ali, W., Yang, Y.-f., Gong, L., Yan, C., and Cui, B.-b. Emission characteristics and quantitative health risk assessment of bioaerosols in an indoor toilet after flushing under various ventilation scenarios. [Online]. Building and Environment. 2022, 207, article no: 108463 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2021.108463. [268] Chen, Y.-h., Yan, C., Yang, Y.-f., and Ma, J.-x. Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants. [Online]. The Science of the Total Environment. 2021, 755, article no: 142615 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.scitotenv.2020.142615. [269] Ma, J., An, D., Cui, B., Liu, M., Zhu, H., Li, M., Ai, X., Ali, W., and Yan, C. What are the disease burden and its sensitivity analysis of workers exposing to Staphylococcus aureus bioaerosol during warm and cold periods in a wastewater treatment plant? [Online]. Environmental Science and Pollution Research. 2022, 29(55), pp.82938–82947. [Accessed 1 March 2025]. Available from: https://doi.org/10.1007/s11356-022-21447-9. [270] Wu, J.-t., Song, X.-q., Liang, L.-w., and Yan, C. Estimating acceptable exposure time for bioaerosols emission in a wastewater treatment plant by reverse quantitative microbial risk assessment based on various risk benchmarks. [Online]. Environmental Science and Pollution Research. 2022, 29(9), pp.13345–13355. [Accessed 1 March 2025]. Available from: https://doi.org/10.1007/s11356-021-16699-w. [271] Yan, C., Leng, Y.-L., and Wu, J.-T. Quantitative microbial risk assessment for occupational health of temporary entrants and staffs equipped with various grade PPE and exposed to microbial bioaerosols in two WWTPs. [Online]. International Archives of Occupational and Environmental Health. 2021, 94(6), pp.1327–1343. [Accessed 17 March 2025]. Available from: https://doi.org/10.1007/s00420-021-01663-5. [272] Yan, C., Zhao, X.-y., Luo, X., An, D.-z., Zhu, H., Li, M., Ai, X.-j., and Ali, W. Quantitative microbial risk assessment with nasal/oral breathing pattern for S. aureus bioaerosol emission from aeration tanks and residual sludge storage yard in a wastewater treatment plant. [Online]. Environmental Science and Pollution Research. 2023, 30(8), pp.21252–21262. [Accessed 1 March 2025]. Available from: https://doi.org/10.1007/s11356-022-23621-5. [273] Dean, K. and Mitchell, J. Reverse QMRA for Pseudomonas aeruginosa in Premise Plumbing to Inform Risk Management. [Online]. Journal of Environmental Engineering. 2020, 146(3). [Accessed 1 March 2025]. Available from: https://doi.org/10.1061/(ASCE)EE.1943-7870.0001641. [274] Augenbraun, B. L., Lasner, Z. D., Mitra, D., Prabhu, S., Raval, S., Sawaoka, H., and Doyle, J. M. Assessment and mitigation of aerosol airborne SARSCoV-2 transmission in laboratory and office environments. [Online]. Journal of Occupational and Environmental Hygiene. 2020, 17(10), pp.447–456. [Accessed 17 March 2025]. Available from: https://doi.org/10.1080/15459624.2020.1805117. [275] Wagner, J., Sparks, T. L., Miller, S., Chen, W., Macher, J. M., and Waldman, J. M. Modeling the impacts of physical distancing and other exposure determinants on aerosol transmission. [Online]. Journal of Occupational and Environmental Hygiene. 2021, 18(10), pp.495–509. [Accessed 1 March 2025]. Available from: https://doi.org/10.1080/15459624.2021.1963445. [276] Bale, R., Iida, A., Yamakawa, M., Li, C., and Tsubokura, M. Quantifying the COVID19 infection risk due to droplet/aerosol inhalation. [Online]. Scientific Reports. 2022, 12(1), article no: 11186 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1038/s41598-022-14862-y. [277] Cortellessa, G., Stabile, L., Arpino, F., Faleiros, D. E., Bos, W. van den, Morawska, L., and Buonanno, G. Close proximity risk assessment for SARSCoV-2 infection. [Online]. Science of The Total Environment. 2021, 794, article no: 148749 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.scitotenv.2021.148749. [278] Domino, S. P. A Case Study on Pathogen Transport, Deposition, Evaporation and Transmission: Linking High-Fidelity Computational Fluid Dynamics Simulations to Probability of Infection. [Online]. International Journal of Computational Fluid Dynamics. 2021, 35(9), pp.743–757. [Accessed 1 March 2025]. Available from: https://doi.org/10.1080/10618562.2021.1905801. [279] Hedworth, H. A., Karam, M., McConnell, J., Sutherland, J. C., and Saad, T. Mitigation strategies for airborne disease transmission in orchestras using computational fluid dynamics. [Online]. Science Advances. 2021, 7(26), article no: eabg4511 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1126/sciadv.abg4511. [280] Bertone, M., Mikszewski, A., Stabile, L., Riccio, G., Cortellessa, G., d’Ambrosio, F. R., Papa, V., Morawska, L., and Buonanno, G. Assessment of SARS-CoV2 airborne infection transmission risk in public buses. [Online]. Geoscience Frontiers. 2022, 13(6), article no: 101398 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.gsf.2022.101398. [281] Rocha-Melogno, L., Crank, K., Bergin, M. H., Gray, G. C., Bibby, K., and Deshusses, M. A. Quantitative risk assessment of COVID-19 aerosol transmission indoors: a mechanistic stochastic web application. [Online]. Environmental Technology. 2023, 44(9), pp.1201–1212. [Accessed 1 March 2025]. Available from: https://doi.org/10.1080/09593330.2021.1998228. [282] Buonanno, G., Morawska, L., and Stabile, L. Quantitative assessment of the risk of airborne transmission of SARS-CoV-2 infection: Prospective and retrospective applications. [Online]. Environment International. 2020, 145, article no: 106112 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.envint.2020.106112. [283] Dhawan, S. and Biswas, P. Aerosol Dynamics Model for Estimating the Risk from Short-Range Airborne Transmission and Inhalation of Expiratory Droplets of SARS-CoV-2. [Online]. Environmental Science & Technology. 2021, 55(13), pp.8987–8999. [Accessed 1 March 2025]. Available from: https://doi.org/10.1021/acs.est.1c00235. [284] Henriques, A., Mounet, N., Aleixo, L., Elson, P., Devine, J., Azzopardi, G., Andreini, M., Rognlien, M., Tarocco, N., and Tang, J. Modelling airborne transmission of SARS-CoV-2 using CARA: risk assessment for enclosed spaces. [Online]. Interface Focus. 2022, 12(2), article no: 20210076 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1098/rsfs.2021.0076. [285] Parhizkar, H., Van Den Wymelenberg, K. G., Haas, C. N., and Corsi, R. L. A Quantitative Risk Estimation Platform for Indoor Aerosol Transmission of COVID-19. [Online]. Risk Analysis. 2022, 42(9), pp.2075–2088. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/risa.13844. [286] Carducci, A., Donzelli, G., Cioni, L., Federigi, I., Lombardi, R., and Verani, M. Quantitative Microbial Risk Assessment for Workers Exposed to Bioaerosol in Wastewater Treatment Plants Aimed at the Choice and Setup of Safety Measures. [Online]. International Journal of Environmental Research and Public Health. 2018, 15(7), article no: 1490 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.3390/ijerph15071490. [287] Carducci, A., Donzelli, G., Cioni, L., and Verani, M. Quantitative Microbial Risk Assessment in Occupational Settings Applied to the Airborne Human Adenovirus Infection. [Online]. International Journal of Environmental Research and Public Health. 2016, 13(7), article no: 733 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.3390/ijerph13070733. [288] Xu, C., Wei, X., Liu, L., Su, L., Liu, W., Wang, Y., and Nielsen, P. V. Effects of personalized ventilation interventions on airborne infection risk and transmission between occupants. [Online]. Building and Environment. 2020, 180, article no: 107008 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2020.107008. [289] Nicas, M. and Jones, R. M. Relative Contributions of Four Exposure Pathways to Influenza Infection Risk. [Online]. Risk Analysis. 2009, 29(9), pp.1292–1303. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/j.1539-6924.2009.01253.x. [290] Lim, K.-Y., Hamilton, A. J., and Jiang, S. C. Assessment of public health risk associated with viral contamination in harvested urban stormwater for domestic applications. [Online]. Science of The Total Environment. 2015, 523, pp.95–108. [Accessed 5 March 2025]. Available from: https://doi.org/10.1016/j.scitotenv.2015.03.077. [291] Mousavi, E. and Bhattacharya, A. Event based approach for modeling indoor airflow patterns. [Online]. Journal of Building Engineering. 2022, 51, p.104244. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.jobe.2022.104244. [292] Ye, W., Pan, Y., He, L., Chen, B., Liu, J., Gao, J., Wang, Y., and Yang, Y. Design with modeling techniques. In: Goodfellow, H. D. and Wang, Y., eds. Industrial Ventilation Design Guidebook. [Online]. 2nd ed. Elsevier, 2021, pp.109–183. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/b978-0-12-816673-4.00008-0. [293] Noakes, C. J. and Sleigh, P. A. Mathematical models for assessing the role of airflow on the risk of airborne infection in hospital wards. [Online]. Journal of the Royal Society, Interface. 2009, 6, pp.S791–S800. [Accessed 17 March 2025]. Available from: https://doi.org/10.1098/rsif.2009.0305.focus. [294] López-García, M., King, M.-F., and Noakes, C. J. A Multicompartment SIS Stochastic Model with Zonal Ventilation for the Spread of Nosocomial Infections: Detection, Outbreak Management, and Infection Control. [Online]. Risk Analysis. 2019, 39(8), pp.1825–1842. [Accessed 3 March 2025]. Available from: https://doi.org/10.1111/risa.13300. [295] National Institute of Standards and Technology (NIST), CONTAM. [Software]. [Accessed 17 March 2025]. Available from: https://www.nist.gov/services-resources/software/contam. [296] Edwards, A. J., Benson, L., Guo, Z., López-García, M., Noakes, C. J., Peckham, D., and King, M.-F. A mathematical model for assessing transient airborne infection risks in a multi-zone hospital ward. [Online]. Building and Environment. 2023, 238, article no: 110344 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2023.110344. [297] Yan, S., Wang, L., Birnkrant, M. J., Zhai, J., and Miller, S. L. Evaluating SARS-CoV-2 airborne quanta transmission and exposure risk in a mechanically ventilated multizone office building. [Online]. Building and Environment. 2022, 219, article no: 109184 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.109184. [298] Shrestha, P., DeGraw, J. W., Zhang, M., and Liu, X. Multizonal modeling of SARS-CoV-2 aerosol dispersion in a virtual office building. [Online]. Building and Environment. 2021, 206, article no: 108347 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2021.108347. [299] Cheong, C. H., Park, B., and Lee, S. Design Method to Prevent Airborne Infection in an Emergency Department. [Online]. Journal of Asian Architecture and Building Engineering. 2018, 17(3), pp.573–579. [Accessed 3 March 2025]. Available from: https://doi.org/10.3130/jaabe.17.581. [300] Emmerich, S. J., Heinzerling, D., Choi, J.-i., and Persily, A. K. Multizone modeling of strategies to reduce the spread of airborne infectious agents in healthcare facilities. [Online]. Building and Environment. 2013, 60, pp.105–115. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2012.11.013. [301] Navthar, R. R., Kotakar, S. G., and Khire, M. Y., Computational Fluid Dynamics: Computer Simulation. In: 2011 3rd International Conference on Computer Technology and Development, 25 - 27 November 2011, Chengdu. [Online]. ASME Press, 2011. [Accessed 15 January 2025]. Available from: https://doi.org/10.1115/1.859919.paper190. [302] Hathway, E., Noakes, C., Sleigh, P., and Fletcher, L. CFD simulation of irborne pathogen transport due to human activities. [Online]. Building and Environment. 2011, 46(12), pp.2500–2511. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2011.06.001. [303] Wang, J. and Chow, T.-T. Influence of human movement on the transport of airborne infectious particles in hospital. [Online]. Journal of Building Performance Simulation. 2015, 8(4), pp.205–215. [Accessed 3 March 2025]. Available from: https://doi.org/10.1080/19401493.2014.905636. [304] Jo, S., Hong, J., Lee, S.-E., Ki, M., Choi, B. Y., and Sung, M. Airflow analysis of Pyeongtaek St Mary’s Hospital during hospitalization of the first Middle East respiratory syndrome patient in Korea. [Online]. Royal Society Open Science. 2019, 6(3), article no: 181164 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1098/rsos.181164. [305] Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., and Qian, H. Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong. [Online]. Indoor Air. 2005, 15(2), pp.83–95. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/j.1600-0668.2004.00317.x. [306] ANSYS, Inc., ANSYS Fluent (version 2023 R2). [Software]. 2023. [Accessed 3 January 2025]. Available from: https://www.ansys.com/products. [307] Siemens Digital Industries Software, STAR CCM+. [Software]. [Accessed 17 March 2025]. Available from: https://plm.sw.siemens.com/en-US/simcenter/fluids-thermal-simulation/star-ccm/. [308] Mirzaie, M., Lakzian, E., Khan, A., Warkiani, M. E., Mahian, O., and Ahmadi, G. COVID-19 spread in a classroom equipped with partition – A CFD approach. [Online]. Journal of Hazardous Materials. 2021, 420, article no: 126587 [no pagination]. [Accessed 21 January 2025]. Available from: https://doi.org/10.1016/j.jhazmat.2021.126587. [309] Abuhegazy, M., Talaat, K., Anderoglu, O., and Poroseva, S. V. Numerical investigation of aerosol transport in a classroom with relevance to COVID-19. [Online]. Physics of Fluids. 2020, 32(10), article no: 103311 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1063/5.0029118. [310] Foster, A. and Kinzel, M. Estimating COVID-19 exposure in a classroom setting: A comparison between mathematical and numerical models. [Online]. Physics of Fluids. 2021, 33(2), article no: 021904 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1063/5.0040755. [311] Pei, G., Azimi, P., Rim, D., and Allen, J. G. A CFD study on the effect of portable air cleaner placement on airborne infection control in a classroom. [Online]. Environmental science. Processes & impacts. 2024, 26(9), pp.1476–1488. [Accessed 3 March 2025]. Available from: https://doi.org/10.1039/d4em00114a. [312] Firatoglu, Z. A. The effect of natural ventilation on airborne transmission of the COVID-19 virus spread by sneezing in the classroom. [Online]. The Science of the Total Environment. 2023, 896, article no: 165113 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.scitotenv.2023.165113. [313] ElShimi, M., Morcos, S. M., Mostafa, G. M., Khalil, E. E., El-Hariry, G. A., and ElDegwy, A. A novel transparent cabin used in the classroom during the coronavirus pandemic: a CFD analysis. [Online]. Journal of Engineering and Applied Science. 2024, 71(1), article no: 19 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1186/s44147-023-00316-3. [314] Yan, W., Zhang, Y., Sun, Y., and Li, D. Experimental and CFD study of unsteady airborne pollutant transport within an aircraft cabin mock-up. [Online]. Building and Environment. 2009, 44(1), pp.34–43. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2008.01.010. [315] Webner, F., Shishkin, A., Schmeling, D., and Wagner, C. A Direct Infection Risk Model for CFD Predictions and Its Application to SARS-CoV-2 Aircraft Cabin Transmission. [Online]. Indoor Air. 2024, 2024(1), article no: 9927275 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1155/2024/9927275. [316] Zee, M., Davis, A. C., Clark, A. D., Wu, T., Jones, S. P., Waite, L. L., Cummins, J. J., and Olson, N. A. Computational fluid dynamics modeling of cough transport in an aircraft cabin. [Online]. Scientific Reports. 2021, 11(1), article no: 23329 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1038/s41598-021-02663-8. [317] ANSYS, Inc. ANSYS Fluent Theory Guide. [Online]. 2021. [Accessed 22 January 2025]. Available from: https://www.afs.enea.it/project/neptunius/docs/fluent/html/th/main_pre.htm. [318] Ge, X., Wang, H., Liu, S., Li, Z., Tong, X., and Pu, J. Application of Fibonacci Sequence and Lucas Sequence on the Design of the Toilet Siphon Pipe Shape. [Online]. Journal of Engineering and Technological Sciences. 2019, 51(4), pp.463–478. [Accessed 18 February 2025]. Available from: https://doi.org/10.5614/j.eng.technol.sci.2019.51.4.2. [319] Li, Z., Ge, X., Li, K., and Tong, X. Siphon pipe parameter optimization of the toilet using CFD-DEM coupling method. [Online]. International Journal of Numerical Methods for Calculation and Design in Engineering. 2021, 37(1). [Accessed 18 February 2025]. Available from: https://doi.org/10.23967/j.rimni.2020.10.003. [320] Yang, S., Zhang, Y., Hemida, H., Wang, Y., and Ren, D. Flow Field Simulation Analysis of Train Siphon Toilet with Variable Pipe Diameter Based on the Investigation of Siphon Performance. [Online]. Journal of Physics: Conference Series. 2020, 1626(1), p.012099. [Accessed 18 February 2025]. Available from: https://doi.org/10.1088/1742-6596/1626/1/012099. [321] Wang, Y., Xiu, G., and Tan, H. CAD and CAE Analysis for Siphon Jet Toilet. [Online]. Physics Procedia. 2011, 19, pp.472–476. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.phpro.2011.06.194. [322] Wu, S.-C., Guo, M.-Y., Wang, J.-X., Yao, S., Chen, J., and Li, Y.-y. Liquid curtain-based strategy to restrain plume during flushing. [Online]. Physics of Fluids. 2020, 32(11), article no: 111707 [no pagination]. [Accessed 11 February 2025]. Available from: https://doi.org/10.1063/5.0033836. [323] Wan, J., Wei, J., Lin, Y., and Zhang, T. Numerical Investigation of Bioaerosol Transport in a Compact Lavatory. [Online]. Buildings. 2021, 11(11), article no: 526 [no pagination]. [Accessed 22 January 2025]. Available from: https://doi.org/10.3390/buildings11110526. [324] Li, P., Liu, W., and Zhang, T. T. CFD modeling of dynamic airflow and particle transmission in an aircraft lavatory. [Online]. Building Simulation. 2023, 16(8), pp.1375–1390. [Accessed 18 February 2025]. Available from: https://doi.org/10.1007/s12273-023-1031-3. [325] COMSOL, Inc., COMSOL. [Software]. 2024. [Accessed 17 March 2025]. Available from: https://www.comsol.com/. [326] Liu, H., Zhang, Z., Zhang, Y., and Zhou, X. Impact of ventilation efficiency on restraining hazardous toilet plume post-flushing in indoor environments. [Online]. Indoor and Built Environment. 2024, 33(10), pp.1897–1911. [Accessed 21 January 2025]. Available from: https://doi.org/10.1177/1420326X241262650. [327] Ho, M. S., Glass, R. I., Monroe, S. S., Madore, H. P., Stine, S., Pinsky, P. F., Cubitt, D., Ashley, C., and Caul, E. O. Viral gastroenteritis aboard a cruise ship. [Online]. Lancet (London, England). 1989, 2(8669), pp.961–965. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/s0140-6736(89)90964-1. [328] Widdowson, M.-A., Glass, R., Monroe, S., Beard, R. S., Bateman, J. W., Lurie, P., and Johnson, C. Probable Transmission of Norovirus on an Airplane. [Online]. JAMA. 2005, 293(15), pp.1855–1860. [Accessed 15 January 2025]. Available from: https://doi.org/10.1001/jama.293.15.1859. [329] National Research Council (US) Subcommittee on Microbiological Criteria. An Evaluation of the Role of Microbiological Criteria for Foods and Food Ingredients. [Online]. National Academies Press, 1985. [Accessed 24 February 2025]. Available from: https://doi.org/10.17226/372. [330] Percival, S. L., Yates, M. V., Williams, D. D., Chalmers, R., and Gray, N. Microbiology of Waterborne Diseases: Microbiological Aspects and Risks. [Online]. 2nd ed. Elsevier, 2014. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/C2010-0-67101-X. [331] Seidman, L., Kraus, M., Brandner, D., and Mowery, J. Laboratory Manual for Biotechnology and Laboratory Science. [Online]. CRC Press, 2022. [Accessed 17 March 2025]. Available from: https://doi.org/10.1201/9781003360742. [332] Noakes, C. J., Fletcher, L. A., Sleigh, P. A., Booth, W. B., Beato-Arribas, B., and Tomlinson, N., Comparison of tracer techniques for evaluating the behaviour of bioaerosols in hospital isolation rooms. In Proceedings of the Healthy Buildings, Kuala Lumpur, Malaysia, 13–17 September 2009. In: 9th International Conference and Exhibition on Healthy Buildings 2009, 13 – 17 September 2009, Syracuse. [Online]. ISIAQ, 2009, pp.1642–1645. [Accessed 17 March 2025]. Available from: https://www.proceedings.com/17570.html. [333] King, M.-F., Camargo-Valero, M., Matamoros-Veloza, A., Sleigh, P., and Noakes, C. J. An Effective Surrogate Tracer Technique for S. aureus Bioaerosols in a Mechanically Ventilated Hospital Room Replica Using Dilute Aqueous Lithium Chloride. [Online]. Atmosphere. 2017, 8(12), article no: 238 [no pagination]. [Accessed 23 May 2024]. Available from: https://doi.org/10.3390/atmos8120238. [334] Huang, H.-L., Lee, M.-K., and Shih, H.-W. Assessment of Indoor Bioaerosols n Public Spaces by Real-Time Measured Airborne Particles. [Online]. Aerosol and Air Quality Research. 2017, 17(9), pp.2276–2288. [Accessed 24 February 2025]. Available from: https://doi.org/10.4209/aaqr.2017.02.0089. [335] Božić, J., Ilić, P., and Ilić, S. Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems. [Online]. Brazilian Archives of Biology and Technology. 2019, 62, article no: p.e19180295 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/https://doi.org/10.1590/1678-4324-2019180295. [336] Boone, S. A., Ijaz, M. K., McKinney, J., and Gerba, C. P. Resuspension and Dissemination of MS2 Virus from Flooring After Human Activities in Built Environment: Impact of Dust Particles. [Online]. Microorganisms. 2024, 12(12), article no: 2564 [no pagination]. [Accessed 31 January 2025]. Available from: https://doi.org/10.3390/microorganisms12122564. [337] Wanger, A., Chavez, V., Huang, R. S. P., Wahed, A., Actor, J. K., and Dasgupta, A. Media for the Clinical Microbiology Laboratory. In: Wanger, A., Chavez, V., Huang, R. S. P., Wahed, A., Actor, J. K., and Dasgupta, A., eds. Microbiology and Molecular Diagnosis in Pathology. [Online]. Elsevier, 2017, pp.51–60. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/b978-0-12-805351-5.00004-1. [338] Hiwar, W., Kharrufa, H., King, M.-F., Salman, N., Fletcher, L., and Noakes, C., Multiplate air passive sampler to measure deposition rate of airborne microorganisms over time. In: 16th Conference of the International Society of Indoor Air Quality & Climate, 1 - 5 November 2020, Online. [Online]. ISIAQ, 2021, pp.708–713. [Accessed 17 March 2025]. Available from: https://www.proceedings.com/57711.html. [339] Hiwar, W., King, M.-F., Kharrufa, H., Tidswell, E., Fletcher, L. A., and Noakes, C. J. The impact of ventilation rate on reducing the microorganisms load in the air and on surfaces in a room-sized chamber. [Online]. Indoor Air. 2022, 32(11), article no: e13161 [no pagination]. [Accessed 20 February 2025]. Available from: https://doi.org/10.1111/ina.13161. [340] Hathway, A., Sleigh, A., and Noakes, C., CFD modelling of transient pathogen release in indoor environments due to human activity. In: International Conference on Room Air Distribution RoomVent 2007, 13 - 15 June 2007, Finland. [Online]. FINVAC, 2007. [Accessed 17 March 2025]. Available from: https://eprints.whiterose.ac.uk/7699/1/Hathway_Roomvent07.pdf. [341] NHS England. Health Technical Memorandum 03-01: Specialised ventilation for healthcare premises. [Online]. 2021. [Accessed 17 March 2025]. Available from: https://www.england.nhs.uk/publication/specialised-ventilationfor-healthcare-buildings/. [342] Cantium Scientific. Correction of sample counts. [Online]. [Accessed 7 March 2025]. Available from: https://confluence.external-share.com/content/685314/countcorrection. [343] The British Standards Institution. BS 6465-2:2017: Sanitary installations: Space recommendations. Code of practice. [Online]. 2017. [Accessed 17 March 2025]. Available from: https://knowledge.bsigroup.com/products/sanitaryinstallations-space-recommendations-code-of-practice. [344] R Foundation for Statistical Computing, R: A Language and Environment for Statistical Computing. [Software]. 2023. [Accessed 17 March 2025]. Available from: https://www.R-project.org/. [345] Schmid-Hempel, P. and Frank, S. A. Pathogenesis, Virulence, and Infective Dose. [Online]. PLoS Pathogens. 2007, 3(10), article no: e147 [no pagination]. [Accessed 23 February 2025]. Available from: https://doi.org/10.1371/journal.ppat.0030147. [346] Ramlal, P. S., Lin, J., Buckley, C. A., Stenström, T. A., and Amoah, I. D. An assessment of the health risks associated with shared sanitation: a case study of the community ablution blocks in Durban, South Africa. [Online]. Environmental Monitoring and Assessment. 2022, 194(3), article no: 166 [no pagination]. [Accessed 23 February 2025]. Available from: https://doi.org/10.1007/s10661-022-09815-x. [347] Higham, C. A., López-García, M., Noakes, C. J., Tidswell, E., and Fletcher, L. A Quantitative Microbial Risk Assessment (QMRA) framework for exposure from toilet flushing using experimental aerosol concentration measurements. [Online]. Indoor Environments. 2025, 2(1), article no: 100069 [no pagination]. [Accessed 10 March 2025]. Available from: https://doi.org/10.1016/j.indenv.2024.100069. [348] Rawls, S. K. Restroom usage in selected public buildings and facilities: a comparison of females and males. Ph.D thesis. Virginia Polytechnic Institute and State University, 1988. [349] Gwynne, S. M. V., Hunt, A. L. E., Thomas, J. R., Thompson, A. J. L., and Séguin, L. The toilet paper: Bathroom dwell time observations at an airport. [Online]. Journal of Building Engineering. 2019, 24, article no: 100751 [no pagination]. [Accessed 21 May 2024]. Available from: https://doi.org/10.1016/j.jobe.2019.100751. [350] Baillie, M. A., Fraser, S., and Brown, M. J. Do women spend more time in the restroom than men? [Online]. Psychological Reports. 2009, 105(3), pp.789–790. [Accessed 8 September 2024]. Available from: https://doi.org/10.2466/PR0.105.3.789-790."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Integrated Ph.D and Master"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/S022732/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/36775/1/Higham_CA_Computing_PhD_2025.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Toilet flushing is known to generate aerosol plumes that can contain pathogenic microorganisms, and shared toilet facilities have been implicated in the transmission of infectious diseases. However, few studies have quantified the infection risks posed by these aerosols or investigated in detail how they disperse after flushing. This thesis presents an integrated analysis of airborne infection risks associated with toilet plume aerosols, combining controlled experimental studies, quantitative microbial risk assessment (QMRA), and computational fluid dynamics (CFD) simulations. The aim is to investigate aerosol generation, dispersion, and mitigation strategies in shared toilet settings. Controlled chamber experiments were conducted using a gravity-flow, close-coupled toilet, with and without a cubicle enclosure over a range of ventilation rates. The generation of aerosols was characterised by flushing a salt solution, revealing a large proportion of smaller particles (< 5 μm). Particle concentrations peaked in the first 1 min after flushing and returned to background levels within 10 min. Bioaerosol sampling using Escherichia coli showed that most bacteria were released in the first 5 min after flushing, with ventilation rates having a modest influence on airborne concentrations. Continuous but low-level bacterial deposition suggested cumulative risks from surface contamination. A QMRA framework was developed to assess the infection risks associated with single flushing events, accounting for transient aerosol dynamics and realistic occupancy durations. Two models were developed: one combining particle concentrations with estimated viral loads, and another using measured bioaerosol data. When applied to the experimental results, these models suggested non-negligible infection risks, particularly for pathogens present at high faecal concentrations, such as norovirus. The introduction of short delays (> 1 min) between toilet users significantly reduced the estimated infection risks. CFD simulations further examined aerosol dispersion and exposure risks, demonstrating how room layout, ventilation rate, and outlet positioning influence aerosol removal. Optimised ventilation strategies, including increased airflow and repositioned outlets, substantially reduced airborne particle concentrations. This research provides new insights and robust methods to evaluate and mitigate airborne infection risks from toilet plume aerosols, with implications for public health guidance and the design of safer shared toilet environments."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Characterising the Emission and Dispersion of Aerosols from the Toilet Plume and Quantification of the Associated Infection Risk"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fletcher, Louise A.","Noakes, Catherine J.","López-García, Martín"],"dc:contributor.sponsor":["UK Research and Innovation"],"dc:creator":["Higham, Ciara Angel"],"dc:date":["2025-05"],"dc:date.issued":["2025-05"],"dc:description.abstract":["Toilet flushing is known to generate aerosol plumes that can contain pathogenic microorganisms, and shared toilet facilities have been implicated in the transmission of infectious diseases. However, few studies have quantified the infection risks posed by these aerosols or investigated in detail how they disperse after flushing. This thesis presents an integrated analysis of airborne infection risks associated with toilet plume aerosols, combining controlled experimental studies, quantitative microbial risk assessment (QMRA), and computational fluid dynamics (CFD) simulations. The aim is to investigate aerosol generation, dispersion, and mitigation strategies in shared toilet settings. Controlled chamber experiments were conducted using a gravity-flow, close-coupled toilet, with and without a cubicle enclosure over a range of ventilation rates. The generation of aerosols was characterised by flushing a salt solution, revealing a large proportion of smaller particles (< 5 μm). Particle concentrations peaked in the first 1 min after flushing and returned to background levels within 10 min. Bioaerosol sampling using Escherichia coli showed that most bacteria were released in the first 5 min after flushing, with ventilation rates having a modest influence on airborne concentrations. Continuous but low-level bacterial deposition suggested cumulative risks from surface contamination. A QMRA framework was developed to assess the infection risks associated with single flushing events, accounting for transient aerosol dynamics and realistic occupancy durations. Two models were developed: one combining particle concentrations with estimated viral loads, and another using measured bioaerosol data. When applied to the experimental results, these models suggested non-negligible infection risks, particularly for pathogens present at high faecal concentrations, such as norovirus. The introduction of short delays (> 1 min) between toilet users significantly reduced the estimated infection risks. CFD simulations further examined aerosol dispersion and exposure risks, demonstrating how room layout, ventilation rate, and outlet positioning influence aerosol removal. Optimised ventilation strategies, including increased airflow and repositioned outlets, substantially reduced airborne particle concentrations. This research provides new insights and robust methods to evaluate and mitigate airborne infection risks from toilet plume aerosols, with implications for public health guidance and the design of safer shared toilet environments."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/S022732/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/36775/1/Higham_CA_Computing_PhD_2025.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Computing (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/36775/"],"dc:relation.references":["[1] World Health Organization. Global technical consultation report on proposed terminology for pathogens that transmit through the air. [Online]. 2024. [Accessed 15 March 2025]. Available from: https://www.who.int/publications/m/item/global-technical-consultation-report-on-proposed-terminology-for-pathogens-that-transmit-through-the-air. [2] Johnson, D., Lynch, R., Marshall, C., Mead, K., and Hirst, D. Aerosol Generation by Modern Flush Toilets. [Online]. Aerosol Science and Technology. 2013, 47(9), pp.1047–1057. [Accessed 14 November 2023]. Available from: https://doi.org/10.1080/02786826.2013.814911. [3] Henning, D. N. Use of public washrooms in an enclosed, suburban shopping plaza. [Online]. National Research Council of Canada, 1977. [Accessed 4 January 2024]. Available from: https://doi.org/10.4224/20359222. [4] King, M.-F., Noakes, C., Sleigh, A., and Camargo-Valero, M. Bioaerosol deposition in single and two-bed hospital rooms: A numerical and experimental study. [Online]. Building and Environment. 2013, 59, pp.436–447. [Accessed 4 April 2024]. Available from: https://doi.org/10.1016/j.buildenv.2012. 09.011. [5] Lopez, G. U., Gerba, C. P., Tamimi, A. H., Kitajima, M., Maxwell, S. L., and Rose, J. B. Transfer efficiency of bacteria and viruses from porous and nonporous fomites to fingers under different relative humidity conditions. [Online]. Applied and Environmental Microbiology. 2013, 79(18), pp.5728– 5734. [Accessed 9 January 2023]. Available from: https://doi.org/10.1128/AEM.01030-13. [6] Lai, A. C. K., Tan, T. F., Li, W. S., and Ip, D. K. M. Emission strength of airborne pathogens during toilet flushing. [Online]. Indoor Air. 2018, 28(1), pp.73–79. [Accessed 3 September 2024]. Available from: https://doi.org/10.1111/ina.12406. [7] Zhang, T., Yao, L., Gao, Z., and Wang, F. Particle exposure risk to a lavatory user after flushing a squat toilet. [Online]. Scientific Reports. 2022, 12(1), article no: 21088 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1038/s41598-022-25106-4. [8] Li, P., Zhang, T., and Zhang, Y. Measuring the flushing-generated flow and aerosols in lavatory of commercial aircraft. [Online]. Building and Environment. 2022, 214, article no: 108948 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.108948. [9] Cai, C., Kim, P., Connor, T. H., Liu, Y., and Floyd, E. L. Reducing the particles generated by flushing institutional toilets. [Online]. Journal of Occupational and Environmental Hygiene. 2022, 19(5), pp.318–326. [Accessed 25 February 2025]. Available from: https://doi.org/10.1080/15459624. 2022.2053693. [10] Gerba, C. P., Wallis, C., and Melnick, J. L. Microbiological Hazards of Household Toilets: Droplet Production and the Fate of Residual Organisms. [Online]. Applied Microbiology. 1975, 30(2), pp.229–237. [Accessed 13 November 2023]. Available from: https://doi.org/10.1128/am.30.2.229-237.1975. [11] Darlow, H. M. and Bale, W. R. Infective hazards of water-closets. [Online]. The Lancet. 1959, 273(7084), pp.1196–1200. [Accessed 13 November 2023]. Available from: https://doi.org/10.1016/S0140-6736(59)91201-2. [12] Knowlton, S. D., Boles, C. L., Perencevich, E. N., Diekema, D. J., Nonnenmann, M. W., and CDC Epicenters Program. Bioaerosol concentrations generated from toilet flushing in a hospital-based patient care setting. [Online]. Antimicrobial Resistance & Infection Control. 2018, 7(1), article no: 16 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi. org/10.1186/s13756-018-0301-9. [13] Paddy, E. N., Afolabi, O. O. D., and Sohail, M. Exploring toilet plume bioaerosol exposure dynamics in public toilets using a Design of Experiments approach. [Online]. Scientific Reports. 2024, 14(1), article no: 10665 [no pagination]. [Accessed 21 February 2025]. Available from: https://doi.org/10. 1038/s41598-024-61039-w. [14] Haas, C. N., Rose, J. B., and Gerba, C. P. Quantitative Microbial Risk Assessment. [Online]. 2nd ed. Wiley, 2014. [Accessed 15 March 2024]. Available from: https://doi.org/10.1002/9781118910030. [15] Rangel, J. M., Sparling, P. H., Crowe, C., Griffin, P. M., and Swerdlow, D. L. Epidemiology of Escherichia coli O157:H7 Outbreaks, United States, 1982–2002. [Online]. Emerging Infectious Diseases. 2005, 11(4), pp.603–609. [Accessed 27 February 2025]. Available from: https://doi.org/10.3201/eid1104.040739. [16] Czepiel, J., Dróżdż, M., Pituch, H., Kuijper, E. J., Perucki, W., Mielimonka, A., Goldman, S., Wultańska, D., Garlicki, A., and Biesiada, G. Clostridium difficile infection: review. [Online]. European Journal of Clinical Microbiology & Infectious Diseases. 2019, 38(7), pp.1211–1221. [Accessed 5 November 2024]. Available from: https://doi.org/10.1007/s10096-019-03539-6. [17] Teunis, P. F. M., Sukhrie, F. H. A., Vennema, H., Bogerman, J., Beersma, M. F. C., and Koopmans, M. P. G. Shedding of norovirus in symptomatic and asymptomatic infections. [Online]. Epidemiology and Infection. 2015, 143(8), pp.1710–1717. [Accessed 20 November 2024]. Available from: https://doi. org/10.1017/S095026881400274X. [18] Crawford, S. E., Ramani, S., Tate, J. E., Parashar, U. D., Svensson, L., Hagbom, M., Franco, M. A., Greenberg, H. B., O’Ryan, M., Kang, G., Desselberger, U., and Estes, M. K. Rotavirus infection. [Online]. Nature Reviews Disease Primers. 2017, 3(1), pp.1–16. [Accessed 27 February 2025]. Available from: https://doi.org/10.1038/nrdp.2017.83. [19] McKinney, K. R., Gong, Y. Y., and Lewis, T. G. Environmental transmission of SARS at Amoy Gardens. [Online]. Journal of Environmental Health. 2006, 68(9), pp.26–52. [Accessed 6 February 2023]. Available from: https://pubmed.ncbi.nlm.nih.gov/32569870/. [20] Termansen, M. B. and Frische, S. Fecal-oral transmission of SARS-CoV-2: A systematic review of evidence from epidemiological and experimental studies. [Online]. American Journal of Infection Control. 2023, 51(12), pp.1430–1437. [Accessed 19 November 2024]. Available from: https://doi.org/10.1016/j. ajic.2023.04.170. [21] Tan, M., Tian, Y., Zhang, D., Wang, Q., and Gao, Z. Aerosol Transmission of Norovirus. [Online]. Viruses. 2024, 16(1), article no: 151 [no pagination]. [Accessed 16 May 2024]. Available from: https://doi.org/10.3390/v16010151. [22] Ahmed, S. M., Hall, A. J., Robinson, A. E., Verhoef, L., Premkumar, P., Parashar, U. D., Koopmans, M., and Lopman, B. A. Global prevalence of norovirus in cases of gastroenteritis: a systematic review and meta-analysis. [Online]. The Lancet. Infectious Diseases. 2014, 14(8), pp.725–730. [Accessed 9 February 2023]. Available from: https://doi.org/10.1016/S1473-3099(14) 70767-4. [23] Sandmann, F. G., Shallcross, L., Adams, N., Allen, D. J., Coen, P. G., Jeanes, A., Kozlakidis, Z., Larkin, L., Wurie, F., Robotham, J. V., Jit, M., and Deeny, S. R. Estimating the Hospital Burden of Norovirus-Associated Gastroenteritis in England and Its Opportunity Costs for Nonadmitted Patients. [Online]. Clinical Infectious Diseases. 2018, 67(5), pp.693–700. [Accessed 11 March 2025]. Available from: https://doi.org/10.1093/cid/ciy167. [24] Robilotti, E., Deresinski, S., and Pinsky, B. A. Norovirus. [Online]. Clinical Microbiology Reviews. 2015, 28(1), pp.134–164. [Accessed 21 January 2025]. Available from: https://doi.org/10.1128/CMR.00075-14. [25] UK Health Security Agency. National norovirus and rotavirus surveillance reports: 2024 to 2025 season. [Online]. 2025. [Accessed 11 February 2025]. Available from: https://www.gov.uk/government/statistics/national-norovirus-and-rotavirus-surveillance-reports-2024-to-2025-season/national-norovirus-and-rotavirus-report-week-10-report-data-to-week-8-data-up-to-23-february-2025. [26] NHS England. NHS norovirus pressure hits winter high. [Online]. 2025. [Accessed 18 March 2025]. Available from: https://www.england.nhs.uk/2025/01/nhs-norovirus-pressure-hits-winter-high/. [27] Alsved, M., Nyström, K., Thuresson, S., Nygren, D., Patzi-Churqui, M., Hussein, T., Fraenkel, C.-J., Medstrand, P., and Löndahl, J. Infectivity of exhaled SARS-CoV-2 aerosols is sufficient to transmit COVID-19 within minutes. [Online]. Scientific Reports. 2023, 13(1), article no: 21245 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1038/s41598-023-47829-8. [28] Hungerford, D., Vivancos, R., Read, J. M., Iturriza-Gomara, M., French, N., and Cunliffe, N. A. Rotavirus vaccine impact and socioeconomic deprivation: an interrupted time-series analysis of gastrointestinal disease outcomes across primary and secondary care in the UK. [Online]. BMC Medicine. 2018, 16(1), article no: 10 [no pagination]. [Accessed 11 March 2025]. Available from: https://doi.org/10.1186/s12916-017-0989-z. [29] Sadiq, A., Bostan, N., Yinda, K. C., Naseem, S., and Sattar, S. Rotavirus: Genetics, pathogenesis and vaccine advances. [Online]. Reviews in Medical Virology. 2018, 28(6), article no: e2003 [no pagination]. [Accessed 12 March 2024]. Available from: https://doi.org/10.1002/rmv.2003. [30] Wilde, J., Van, R., Pickering, L., Eiden, J., and Yolken, R. Detection of rotaviruses in the day care environment by reverse transcriptase polymerase chain reaction. [Online]. The Journal of Infectious Diseases. 1992, 166(3), pp.507–511. [Accessed 12 April 2024]. Available from: https://doi.org/10. 1093/infdis/166.3.507. [31] Bager, P., Svalgaard, I. B., Lomholt, F. K., Emborg, H.-D., Christiansen, L. E., Soborg, B., Hviid, A., and Vestergaard, L. S. The hospital and mortality burden of COVID-19 compared with influenza in Denmark: a national observational cohort study, 2022–24. [Online]. The Lancet Infectious Diseases. 2025, 0(0). [Accessed 11 March 2025]. Available from: https://doi.org/10. 1016/S1473-3099(24)00806-5. [32] Liu, E., Dean, C. A., and Elder, K. T. Editorial: The impact of COVID-19 on vulnerable populations. [Online]. Frontiers in Public Health. 2023, 11, article no: 1267723 [no pagination]. [Accessed 12 March 2025]. Available from: https://doi.org/10.3389/fpubh.2023.1267723. [33] Wu, Y., Guo, C., Tang, L., Hong, Z., Zhou, J., Dong, X., Yin, H., Xiao, Q., Tang, Y., Qu, X., Kuang, L., Fang, X., Mishra, N., Lu, J., Shan, H., Jiang, G., and Huang, X. Prolonged presence of SARS-CoV-2 viral RNA in faecal samples. [Online]. The Lancet Gastroenterology & Hepatology. 2020, 5(5), pp.434–435. [Accessed 11 March 2025]. Available from: https://doi. org/10.1016/S2468-1253(20)30083-2. [34] Kaper, J. B., Nataro, J. P., and Mobley, H. L. T. Pathogenic Escherichia coli. [Online]. Nature Reviews Microbiology. 2004, 2(2), pp.123–140. [Accessed 11 March 2025]. Available from: https://doi.org/10.1038/nrmicro818. [35] UK Health Security Agency. Annual epidemiological commentary: Gram-negative, MRSA, MSSA bacteraemia and C. difficile infections, up to and including financial year 2023 to 2024. [Online]. 2024. [Accessed 11 March 2025]. Available from: https://www.gov.uk/government/statistics/mrsa-mssa-and-e-coli-bacteraemia-and-c-difficile-infection-annual-epidemiological-commentary/annual-epidemiological-commentary-gram-negative-mrsa-mssa-bacteraemia-and-c-difficile-infections-up-to-and-including-financial-year-2023-to-2024. [36] Ludden, C., Coll, F., Gouliouris, T., Restif, O., Blane, B., Blackwell, G. A., Kumar, N., Naydenova, P., Crawley, C., Brown, N. M., Parkhill, J., and Peacock, S. J. Defining nosocomial transmission of Escherichia coli and antimicrobial resistance genes: a genomic surveillance study. [Online]. The Lancet Microbe. 2021, 2(9), pp.e472–e480. [Accessed 11 March 2025]. Available from: https://doi.org/10.1016/S2666-5247(21)00117-8. [37] Manning, S., Alcamo, I., and Heymann, D. Escherichia Coli Infections. [Online]. 3rd ed. Chelsea House, 2020. [Accessed 17 March 2025]. Available from: https://books.google.co.uk/books?id=UWmLEAAAQBAJ. [38] Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., and Ho, T. Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus. [Online]. New England Journal of Medicine. 2004, 350(17), pp.1731–1739. [Accessed 4 March 2025]. Available from: https://doi.org/10.1056/NEJMoa032867. [39] Kang, M., Wei, J., Yuan, J., Guo, J., Zhang, Y., Hang, J., Qu, Y., Qian, H., Zhuang, Y., Chen, X., Peng, X., Shi, T., Wang, J., Wu, J., Song, T., He, J., Li, Y., and Zhong, N. Probable Evidence of Fecal Aerosol Transmission of SARS-CoV-2 in a High-Rise Building. [Online]. Annals of Internal Medicine. 2020,173(12), pp.974–980. [Accessed 3 February 2023]. Available from: https://doi.org/10.7326/M20-0928. [40] Malki-Epshtein, L., Adzic, F., Roberts, B. M., Hathway, E. A., Iddon, C., Mustafa, M., and Cook, M. Measurement and rapid assessment of indoor air quality at mass gathering events to assess ventilation performance and reduce aerosol transmission of SARS-CoV-2. [Online]. Building Services Engineering Research & Technology. 2023, 44(2), pp.113–133. [Accessed 19 February 2025]. Available from: https://doi.org/10.1177/01436244221137995. [41] Ali, W., Hu, Z., Tang, Z.-R., Liu, S.-Y., Nasir, Z. A., Coulon, F., Liu, P., and Yan, C. Quantitative microbial risk assessment of bioaerosol emissions from squat and bidet toilets during flushing. [Online]. Risk Analysis. 2025. [Accessed 6 June 2024]. Available from: https://doi.org/10.1111/risa. 70000. [42] Denpetkul, T., Pumkaew, M., Sittipunsakda, O., Leaungwutiwong, P., Mongkolsuk, S., and Sirikanchana, K. Effects of face masks and ventilation on the risk of SARS-CoV-2 respiratory transmission in public toilets: a quantitative microbial risk assessment. [Online]. Journal of Water and Health. 2022, 20(2), pp.300–313. [Accessed 1 March 2025]. Available from: https://doi.org/10. 2166/wh.2022.190. [43] Goforth, M. P., Boone, S. A., Clark, J., Valenzuela, P. B., McKinney, J., Ijaz, M. K., and Gerba, C. P. Impacts of lid closure during toilet flushing and of toilet bowl cleaning on viral contamination of surfaces in United States restrooms. [Online]. American Journal of Infection Control. 2024, 52(2), pp.141–146. [Accessed 8 March 2024]. Available from: https://doi.org/10.1016/j.ajic.2023.11.020. [44] Johnson, D. L., Lynch, R. A., Villanella, S. M., Jones, J. F., Fang, H., Mead, K. R., and Hirst, D. V. L. Persistence of Bowl Water Contamination during Sequential Flushes of Contaminated Toilets. [Online]. Journal of environmental health. 2017, 80(3), pp.34–49. [Accessed 31 January 2025]. Available from: https://pubmed.ncbi.nlm.nih.gov/29651169/. [45] Best, E. L., Sandoe, J. A. T., and Wilcox, M. H. Potential for aerosolization of Clostridium difficile after flushing toilets: the role of toilet lids in reducing environmental contamination risk. [Online]. Journal of Hospital Infection. 2012, 80(1), pp.1–5. [Accessed 13 February 2024]. Available from: https://doi.org/10.1016/j.jhin.2011.08.010. [46] Abney, S., Bright, K., McKinney, J., Ijaz, M. K., and Gerba, C. Toilet hygiene—review and research needs. [Online]. Journal of Applied Microbiology. 2021, 131(6), pp.2705–2714. [Accessed 22 February 2025]. Available from: https://doi.org/10.1111/jam.15121. [47] Barker, J. and Bloomfield, S. F. Survival of Salmonella in bathrooms and toilets in domestic homes following salmonellosis. [Online]. Journal of Applied Microbiology. 2000, 89(1), pp.137–144. [Accessed 4 April 2023]. Available from: https://doi.org/10.1046/j.1365-2672.2000.01091.x. [48] Abney, S. E., Higham, C. A., Wilson, A. M., Ijaz, M. K., McKinney, J., Reynolds, K. A., and Gerba, C. P. Transmission of Viruses from Restroom Use: A Quantitative Microbial Risk Assessment. [Online]. Food and Environmental Virology. 2024, 16(1), pp.65–78. [Accessed 13 September 2024]. Available from: https://doi.org/10.1007/s12560-023-09580-1. [49] Barker, J. and Jones, M. V. The potential spread of infection caused by aerosol contamination of surfaces after flushing a domestic toilet. [Online]. Journal of Applied Microbiology. 2005, 99(2), pp.339–347. [Accessed 3 February 2024]. Available from: https://doi.org/10.1111/j.1365-2672.2005. 02610.x. [50] Ali, W., An, D.-z., Yang, Y.-f., Cui, B.-b., Ma, J.-x., Zhu, H., Li, M., Ai, X.-J., and Yan, C. Comparing bioaerosol emission after flushing in squat and bidet toilets: Quantitative microbial risk assessment for defecation and hand washing postures. [Online]. Building and Environment. 2022, 221, article no: 109284 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.109284. [51] Amoah, I. D., Pillay, L., Deepnarian, N., Awolusi, O., Pillay, K., Ramlal, P., Kumari, S., and Bux, F. Detection of SARS-CoV-2 RNA on contact surfaces within shared sanitation facilities. [Online]. International Journal of Hygiene and Environmental Health. 2021, 236, article no: 113807 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.ijheh.2021.113807. [52] Crimaldi, J. P., True, A. C., Linden, K. G., Hernandez, M. T., Larson, L. T., and Pauls, A. K. Commercial toilets emit energetic and rapidly spreading aerosol plumes. [Online]. Scientific Reports. 2022, 12(1), article no: 20493 [no pagination]. [Accessed 1 October 2023]. Available from: https://doi. org/10.1038/s41598-022-24686-5. [53] Jessen, C. U. Airborne Microorganisms: Occurrance and Control. [Online]. G.E.C. Gad Forlag, Copenhagen. 1955. [Accessed 2 February 2023]. [54] Newsom, S. W. B. Microbiology of hospital toilets. [Online]. The Lancet. 1972, 300(7779), pp.700–703. [Accessed 24 February 2025]. Available from: https://doi.org/10.1016/S0140-6736(72)92102-2. [55] Flügge, C. Ueber Luftinfection. [Online]. Zeitschrift für Hygiene und Infectionskrankheiten. 1897, 25(1), pp.179–224. [Accessed 3 March 2023]. Available from: https://doi.org/10.1007/BF02220473. [56] Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., and Katoshevski, D. Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities. [Online]. Journal of Aerosol Science. 2009, 40(3), pp.256–269. [Accessed 15 January 2025]. Available from: https://doi.org/10.1016/j.jaerosci.2008.11.002. [57] Johnson, G. R., Morawska, L., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Chao, C. Y. H., Wan, M. P., Li, Y., Xie, X., Katoshevski, D., and Corbett, S. Modality of human expired aerosol size distributions. [Online]. Journal of Aerosol Science. 2011, 42(12), pp.839–851. [Accessed 24 February 2025]. Available from: https://doi.org/10.1016/j.jaerosci.2011.07.009. [58] Foat, T. G., Higgins, B., Abbs, C., Maishman, T., Coldrick, S., Kelsey, A., Ivings, M. J., Parker, S. T., and Noakes, C. J. Modeling the effect of temperature and relative humidity on exposure to SARS-CoV-2 in a mechanically ventilated room. [Online]. Indoor Air. 2022, 32(11), article no: e13146 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1111/ina.13146. [59] Stettler, M. E. J., Nishida, R. T., Oliveira, P. M. de, Mesquita, L. C. C., Johnson, T. J., Galea, E. R., Grandison, A., Ewer, J., Carruthers, D., Sykes, D., Kumar, P., Avital, E., Obeysekara, A. I. B., Doorly, D., Hardalupas, Y., Green, D. C., Coldrick, S., Parker, S., and Boies, A. M. Source terms for benchmarking models of SARS-CoV-2 transmission via aerosols and droplets. [Online]. Royal Society Open Science. 2022, 9(5), article no: 212022 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10. 1098/rsos.212022. [60] Calmet, H., Inthavong, K., Both, A., Surapaneni, A., Mira, D., Egukitza, B., and Houzeaux, G. Large eddy simulation of cough jet dynamics, droplet transport, and inhalability over a ten minute exposure. [Online]. Physics of Fluids. 2021, 33(12), article no: 125122 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1063/5.0072148. [61] Coldrick, S., Kelsey, A., Ivings, M. J., Foat, T. G., Parker, S. T., Noakes, C. J., Bennett, A., Rickard, H., and Moore, G. Modeling and experimental study of dispersion and deposition of respiratory emissions with implications for disease transmission. [Online]. Indoor Air. 2022, 32(2), article no: e13000 [no pagination]. [Accessed 13 November 2024]. Available from: https://doi. org/10.1111/ina.13000. [62] Oliveira, P. M. de, Mesquita, L. C. C., Gkantonas, S., Giusti, A., and Mastorakos, E. Evolution of spray and aerosol from respiratory releases: theoretical estimates for insight on viral transmission. [Online]. Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences. 2021, 477(2245), article no: 20200584 [no pagination]. [Accessed 15 January 2025]. Available from: https://doi.org/10.1098/rspa.2020.0584. [63] Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., and Olin, A.-C. Exhaled particles and small airways. [Online]. Respiratory Research. 2019, 20(1), article no: 8 [no pagination]. [Accessed 15 January 2025]. Available from: https://doi.org/10.1186/s12931-019-0970-9. [64] Fennelly, K. P. Particle sizes of infectious aerosols: implications for infection control. [Online]. The Lancet. Respiratory Medicine. 2020, 8(9), pp.914–924. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/S2213-2600(20)30323-4. [65] Gregson, F. K., Watson, N. A., Orton, C. M., Haddrell, A. E., McCarthy, L. P., Finnie, T. J., Gent, R., Donaldson, G. C., Shah, P. L., Calder, J. D., Bzdek, B. R., Costello, D., and Reid, J. P. Comparing aerosol concentrations and particle size distributions generated by singing, speaking and breathing. [Online]. Aerosol Science and Technology. 2021, 55(6), pp.681–691. [Accessed 15 January 2025]. Available from: https://doi.org/10.1080/02786826.2021. 1883544. [66] Yan, J., Grantham, M., Pantelic, J., Bueno de Mesquita, P. J., Albert, B., Liu, F., Ehrman, S., Milton, D. K., and EMIT Consortium. Infectious virus in exhaled breath of symptomatic seasonal influenza cases from a college community. [Online]. Proceedings of the National Academy of Sciences. 2018, 115(5), pp.1081–1086. [Accessed 24 February 2025]. Available from: https://doi.org/10.1073/pnas.1716561115. [67] Lindsley, W. G., Noti, J. D., Blachere, F. M., Thewlis, R. E., Martin, S. B., Othumpangat, S., Noorbakhsh, B., Goldsmith, W. T., Vishnu, A., Palmer, J. E., Clark, K. E., and Beezhold, D. H. Viable Influenza A Virus in Airborne Particles from Human Coughs. [Online]. Journal of Occupational and Environmental Hygiene. 2015, 12(2), pp.107–113. [Accessed 24 February 2025]. Available from: https://doi.org/10.1080/15459624.2014.973113. [68] Coleman, K. K., Tay, D. J. W., Tan, K. S., Ong, S. W. X., Than, T. S., Koh, M. H., Chin, Y. Q., Nasir, H., Mak, T. M., Chu, J. J. H., Milton, D. K., Chow, V. T. K., Tambyah, P. A., Chen, M., and Tham, K. W. Viral Load of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Respiratory Aerosols Emitted by Patients With Coronavirus Disease 2019 (COVID-19) While Breathing, Talking, and Singing. [Online]. Clinical Infectious Diseases.2022, 74(10), pp.1722–1728. [Accessed 8 July 2024]. Available from: https://doi.org/10.1093/cid/ciab691. [69] Malik, M. and Kunze, T. Detection of SARS-CoV-2 RNA in exhaled breath and its potential for prevention measures. [Online]. Infection Prevention in Practice. 2023, 5(3), article no: 100299 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1016/j.infpip.2023.100299. [70] Lane, G., Zhou, G., Hultquist, J. F., Simons, L. M., Redondo, R. L., Ozer, E. A., McCarthy, D. M., Ison, M. G., Achenbach, C. J., Wang, X., Wai, C. M., Wyatt, E., Aalsburg, A., Yang, Q., Noto, T., Alisoltani, A., Ysselstein, D., Awatramani, R., Murphy, R., Theron, G., and Zelano, C. [Pre-print] Quantity of SARS-CoV-2 RNA copies exhaled per minute during natural breathing over the course of COVID-19 infection. [Online]. eLife. 2024. [Accessed 24 February 2025]. Available from: https://doi.org/10.7554/eLife.91686.1. [71] Leung, N. H. L., Chu, D. K. W., Shiu, E. Y. C., Chan, K.-H., McDevitt, J. J., Hau, B. J. P., Yen, H.-L., Li, Y., Ip, D. K. M., Peiris, J. S. M., Seto, W.-H., Leung, G. M., Milton, D. K., and Cowling, B. J. Respiratory virus shedding in exhaled breath and efficacy of face masks. [Online]. Nature Medicine. 2020, 26(5), pp.676–680. [Accessed 24 February 2025]. Available from: https:// doi.org/10.1038/s41591-020-0843-2. [72] Fabian, P., Brain, J., Houseman, E. A., Gern, J., and Milton, D. K. Origin of exhaled breath particles from healthy and human rhinovirus-infected subjects. [Online]. Journal of Aerosol Medicine and Pulmonary Drug Delivery. 2011, 24(3), pp.137–147. [Accessed 10 October 2024]. Available from: https://doi.org/10.1089/jamp.2010.0815. [73] Ghumra, D. P., Shetty, N., McBrearty, K. R., Puthussery, J. V., Sumlin, B. J., Gardiner, W. D., Doherty, B. M., Magrecki, J. P., Brody, D. L., Esparza, T. J., O’Halloran, J. A., Presti, R. M., Bricker, T. L., Boon, A. C. M., Yuede, C. M., Cirrito, J. R., and Chakrabarty, R. K. Rapid Direct Detection of SARS-CoV-2 Aerosols in Exhaled Breath at the Point of Care. [Online]. ACS Sensors. 2023, 8(8), pp.3023–3031. [Accessed 24 February 2025]. Available from: https://doi.org/10.1021/acssensors.3c00512. [74] Lai, J., Coleman, K. K., Tai, S. H. S., German, J., Hong, F., Albert, B., Esparza, Y., Srikakulapu, A. K., Schanz, M., Maldonado, I. S., Oertel, M., Fadul, N., Gold, T. L., Weston, S., Mullins, K., McPhaul, K. M., Frieman, M., and Milton, D. K. Exhaled Breath Aerosol Shedding of Highly Transmissible Versus Prior Severe Acute Respiratory Syndrome Coronavirus 2 Variants. [Online]. Clinical Infectious Diseases. 2022, 76(5), pp.786–794. [Accessed 24 February 2025]. Available from: https://doi.org/10.1093/cid/ciac846. [75] Adenaiye, O. O., Lai, J., Bueno de Mesquita, P. J., Hong, F., Youssefi, S., German, J., Tai, S. H. S., Albert, B., Schanz, M., Weston, S., Hang, J., Fung, C., Chung, H. K., Coleman, K. K., Sapoval, N., Treangen, T., Berry, I. M., Mullins, K., Frieman, M., Ma, T., and Milton, D. K. Infectious Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Exhaled Aerosols and Efficacy of Masks During Early Mild Infection. [Online]. Clinical Infectious Diseases. 2021, 75(1), pp.e241–e248. [Accessed 24 February 2025]. Available from: https://doi.org/10.1093/cid/ciab797. [76] Zheng, Y., Chen, H., Yao, M., and Li, X. Bacterial pathogens were detected from human exhaled breath using a novel protocol. [Online]. Journal of Aerosol Science. 2018, 117, pp.224–234. [Accessed 24 February 2025]. Available from: https://doi.org/10.1016/j.jaerosci.2017.12.009. [77] Anisuzzaman, n., Hossain, M. S., Hatta, T., Labony, S. S., Kwofie, K. D., Kawada, H., Tsuji, N., and Alim, M. A. Food- and vector-borne parasitic zoonoses: Global burden and impacts. [Online]. Advances in Parasitology. 2023, 120, pp.87–136. [Accessed 15 March 2025]. Available from: https://doi.org/10.1016/bs.apar.2023.02.001. [78] Abney, S. E., Ijaz, M. K., McKinney, J., and Gerba, C. P. Laundry Hygiene and Odor Control: State of the Science. [Online]. Applied and Environmental Microbiology. 2021, 87(14), article no: e03002-20 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/10.1128/AEM.03002-20. [79] Rashid, T., VonVille, H., Hasan, I., and Garey, K. Shoe soles as a potential vector for pathogen transmission: a systematic review. [Online]. Journal of Applied Microbiology. 2016, 121(5), pp.1223–1231. [Accessed 24 February 2025]. Available from: https://doi.org/10.1111/jam.13250. [80] Wells, W. F. On Air-borne infection Study II. Droplets and Droplet Nuclei. [Online]. American Journal of Epidemiology. 1934, 20(3), pp.611–618. [Accessed 14 December 2023]. Available from: https://doi.org/10.1093/oxfordjournals.aje.a118097. [81] Randall, K., Ewing, E. T., Marr, L. C., Jimenez, J. L., and Bourouiba, L. How did we get here: what are droplets and aerosols and how far do they go? A historical perspective on the transmission of respiratory infectious diseases. [Online]. Interface Focus. 2021, 11(6), article no: 20210049 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1098/rsfs.2021.0049. [82] Sayers, R. R. and Jones, R. R. Silicosis and Similar Dust Diseases: Medical Aspects and Control. [Online]. Public Health Reports (1896-1970). 1938, 53(33), pp.1453–1472. [Accessed 25 February 2025]. Available from: https://doi.org/10.2307/4582633. [83] Wijk, A. M. V. and Patterson, H. S. The Percentage of Particles of Different Sizes Removed from Dust-Laden Air by Breathing. [Online]. Journal of Industrial Hygiene. 1940, 22, pp.31–35. [Accessed 25 February 2025]. Available from: https://www.cabdirect.org/cabdirect/abstract/19422200462. [84] Langmuir, A. D. The Potentialities of Biological Warfare against Man: An Epidemiological Appraisal. [Online]. Public Health Reports (1896-1970). 1951, 66(13), pp.387–399. [Accessed 15 January 2025]. Available from: https://doi.org/10.2307/4587679. [85] Wells, W. F. Airborne Contagion and Air Hygiene: An Ecological Study of Droplet Infections. [Online]. Journal of the American Medical Association. 1955, 159(1), p.90. [Accessed 15 January 2025]. Available from: https://doi.org/10.1001/jama.1955.02960180092033. [86] Bourouiba, L. Turbulent Gas Clouds and Respiratory Pathogen Emissions: Potential Implications for Reducing Transmission of COVID-19. [Online]. JAMA. 2020, 323(18), pp.1837–1838. [Accessed 18 December 2024]. Available from: https://doi.org/10.1001/jama.2020.4756. [87] Hou, Y. J., Okuda, K., Edwards, C. E., Martinez, D. R., Asakura, T., Dinnon, K. H., Kato, T., Lee, R. E., Yount, B. L., Mascenik, T. M., Chen, G., Olivier, K. N., Ghio, A., Tse, L. V., Leist, S. R., Gralinski, L. E., Schäfer, A., Dang, H., Gilmore, R., Nakano, S., Sun, L., Fulcher, M. L., Livraghi-Butrico, A., Nicely, N. I., Cameron, M., Cameron, C., Kelvin, D. J., Silva, A. de, Margolis, D. M., Markmann, A., Bartelt, L., Zumwalt, R., Martinez, F. J., Salvatore, S. P., Borczuk, A., Tata, P. R., Sontake, V., Kimple, A., Jaspers, I., O’Neal, W. K., Randell, S. H., Boucher, R. C., and Baric, R. S. SARS-CoV-2 Reverse Genetics Reveals a Variable Infection Gradient in the Respiratory Tract. [Online]. Cell. 2020, 182(2), pp.429–446. [Accessed 15 March 2025]. Available from: https://doi.org/10.1016/j.cell.2020.05.042. [88] Chin, A. W. H., Chu, J. T. S., Perera, M. R. A., Hui, K. P. Y., Yen, H.-L., Chan, M. C. W., Peiris, M., and Poon, L. L. M. Stability of SARS-CoV-2 in different environmental conditions. [Online]. The Lancet Microbe. 2020, 1(1), p.e10. [Accessed 15 January 2025]. Available from: https://doi.org/10 .1016/S2666-5247(20)30003-3. [89] Biryukov, J., Boydston, J. A., Dunning, R. A., Yeager, J. J., Wood, S., Reese, A. L., Ferris, A., Miller, D., Weaver, W., Zeitouni, N. E., Phillips, A., Freeburger, D., Hooper, I., Ratnesar-Shumate, S., Yolitz, J., Krause, M., Williams, G., Dawson, D. G., Herzog, A., Dabisch, P., Wahl, V., Hevey, M. C., and Altamura, L. A. Increasing Temperature and Relative Humidity Accelerates Inactivation of SARS-CoV-2 on Surfaces. [Online]. mSphere. 2020, 5(4), article no: e00441-20 [no pagination]. [Accessed 15 January 2025]. Available from: https://doi.org/10.1128/msphere.00441-20. [90] McEldowney, S. and Fletcher, M. The effect of temperature and relative humidity on the survival of bacteria attached to dry solid surfaces. [Online]. Letters in Applied Microbiology. 1988, 7(4), pp.83–86. [Accessed 25 February 2025]. Available from: https://doi.org/10.1111/j.1472-765X.1988.tb01258.x. [91] Pal, R., Sarkar, S., and Mukhopadhyay, A. Influence of ambient conditions on evaporation and transport of respiratory droplets in indoor environment. [Online]. International Communications in Heat and Mass Transfer. 2021, 129, article no: 105750 [no pagination]. [Accessed 15 January 2025]. Available from: https://doi.org/10.1016/j.icheatmasstransfer.2021.105750. [92] Walker, M. D., Vincent, J. C., Benson, L., Stone, C. A., Harris, G., Ambler, R. E., Watts, P., Slatter, T., López-García, M., King, M.-F., Noakes, C. J., and Thomas, R. J. Effect of Relative Humidity on Transfer of Aerosol Deposited Artificial and Human Saliva from Surfaces to Artificial Finger Pads. [Online]. Viruses. 2022, 14(5), article no: 1048 [no pagination]. [Accessed 2 January 2025]. Available from: https://doi.org/10.3390/v14051048. [93] Liu, F., Qian, H., Luo, Z., Wang, S., and Zheng, X. A laboratory study of the expiratory airflow and particle dispersion in the stratified indoor environment. [Online]. Building and Environment. 2020, 180, article no: 106988 [no pagination]. [Accessed 12 March 2025]. Available from: https://doi.org/10. 1016/j.buildenv.2020.106988. [94] Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., and Chwang, A. T. Y. Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems. [Online]. Indoor Air. 2006, 16(2), pp.111– 128. [Accessed 12 March 2025]. Available from: https://doi.org/10.1111/j.1600-0668.2005.00407.x. [95] Sze To, G. N., Wan, M. P., Chao, C. Y. H., Fang, L., and Melikov, A. Experimental Study of Dispersion and Deposition of Expiratory Aerosols in Aircraft Cabins and Impact on Infectious Disease Transmission. [Online]. Aerosol Science and Technology. 2009, 43(5), pp.466–485. [Accessed 18 March 2025]. Available from: https://doi.org/10.1080/02786820902736658. [96] Sun, S., Li, J., and Han, J. How human thermal plume influences near-human transport of respiratory droplets and airborne particles: a review. [Online]. Environmental Chemistry Letters. 2021, 19(3), pp.1971–1982. [Accessed 12 March 2025]. Available from: https://doi.org/10.1007/s10311-020-01178-4. [97] Hobday, R. A. and Dancer, S. J. Roles of sunlight and natural ventilation for controlling infection: historical and current perspectives. [Online]. Journal of Hospital Infection. 2013, 84(4), pp.271–282. [Accessed 12 March 2025]. Available from: https://doi.org/10.1016/j.jhin.2013.04.011. [98] Raiteux, J., Eschlimann, M., Marangon, A., Rogée, S., Dadvisard, M., Taysse, L., and Larigauderie, G. Inactivation of SARS-CoV-2 by Simulated Sunlight on Contaminated Surfaces. [Online]. Microbiology Spectrum. 2021, 9(1), article no: e0033321 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10.1128/spectrum.00333-21. [99] Schuit, M., Gardner, S., Wood, S., Bower, K., Williams, G., Freeburger, D., and Dabisch, P. The Influence of Simulated Sunlight on the Inactivation of Influenza Virus in Aerosols. [Online]. The Journal of Infectious Diseases. 2020, 221(3), pp.372–378. [Accessed 11 August 202]. Available from: https://doi.org/10.1093/infdis/jiz582. [100] West, R., Michie, S., Rubin, G. J., and Amlôt, R. Applying principles of behaviour change to reduce SARS-CoV-2 transmission. [Online]. Nature Human Behaviour. 2020, 4(5), pp.451–459. [Accessed 15 January 2025]. Available from: https://doi.org/10.1038/s41562-020-0887-9. [101] Mousa, A., Winskill, P., Watson, O. J., Ratmann, O., Monod, M., Ajelli, M., Diallo, A., Dodd, P. J., Grijalva, C. G., Kiti, M. C., Krishnan, A., Kumar, R., Kumar, S., Kwok, K. O., Lanata, C. F., Waroux, O. L. P. de, Leung, K., Mahikul, W., Melegaro, A., Morrow, C. D., Mossong, J., Neal, E. F., Nokes, D. J., Panngum, W., Potter, G. E., Russell, F. M., Saha, S., Sugimoto, J. D., Wei, W. I., Wood, R. R., Wu, J., Zhang, J., Walker, P., and Whittaker, C. Social contact patterns and implications for infectious disease transmission – a systematic review and meta-analysis of contact surveys. [Online]. eLife. 2021, 10, article no: e70294 [no pagination]. [Accessed 12 March 2025]. Available from: https://doi.org/10.7554/eLife.70294. [102] Marks, M., Millat-Martinez, P., Ouchi, D., Roberts, C. h., Alemany, A., Corbacho-Monné, M., Ubals, M., Tobias, A., Tebé, C., Ballana, E., Bassat, Q., Baro, B., Vall-Mayans, M., G-Beiras, C., Prat, N., Ara, J., Clotet, B., and Mitjà, O. Transmission of COVID-19 in 282 clusters in Catalonia, Spain: a cohort study. [Online]. The Lancet Infectious Diseases. 2021, 21(5), pp.629–636. [Accessed 15 January 2025]. Available from: https://doi.org/10.1016/S1473-3099(20)30985-3. [103] Marc, A., Kerioui, M., Blanquart, F., Bertrand, J., Mitjà, O., Corbacho-Monné, M., Marks, M., and Guedj, J. Quantifying the relationship between SARS-CoV-2 viral load and infectiousness. [Online]. eLife. 2021, 10, article no: e69302 [no pagination]. [Accessed 2 February 2025]. Available from: https://doi.org/10.7554/eLife.69302. [104] Memoli, M. J., Czajkowski, L., Reed, S., Athota, R., Bristol, T., Proudfoot, K., Fargis, S., Stein, M., Dunfee, R. L., Shaw, P. A., Davey, R. T., and Taubenberger, J. K. Validation of the Wild-type Influenza A Human Challenge Model H1N1pdMIST: An A(H1N1)pdm09 Dose-Finding Investigational New Drug Study. [Online]. Clinical Infectious Diseases. 2015, 60(5), pp.693–702. [Accessed 25 February 2025]. Available from: https://doi.org/10.1093/cid/ciu924. [105] Mayer, B. T., Krantz, E. M., Wald, A., Corey, L., Casper, C., Gantt, S., and Schiffer, J. T. Estimating the Risk of Human Herpesvirus 6 and Cytomegalovirus Transmission to Ugandan Infants from Viral Shedding in Saliva by Household Contacts. [Online]. Viruses. 2020, 12(2), article no: 171 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10. 3390/v12020171. [106] Boucoiran, I., Mayer, B. T., Krantz, E. M., Marchant, A., Pati, S., Boppana, S., Wald, A., Corey, L., Casper, C., Schiffer, J. T., and Gantt, S. Non-Primary Maternal CMV Infection Following Viral Shedding in Infants. [Online]. The Pediatric infectious disease journal. 2018, 37(7), pp.627–631. [Accessed 25 February 2025]. Available from: https://doi.org/10.1097/INF. 0000000000001877. [107] Zeng, L., Li, J., Lv, M., Li, Z., Yao, L., Gao, J., Wu, Q., Wang, Z., Yang, X., Tang, G., Qu, G., and Jiang, G. Environmental Stability and Transmissibility of Enveloped Viruses at Varied Animate and Inanimate Interfaces. [Online]. Environment & Health. 2023, 1(1), pp.15–31. [Accessed 12 March 2025]. Available from: https://doi.org/10.1021/envhealth.3c00005. [108] Vasickova, P., Pavlik, I., Verani, M., and Carducci, A. Issues Concerning Survival of Viruses on Surfaces. [Online]. Food and Environmental Virology. 2010, 2(1), pp.24–34. [Accessed 12 March 2025]. Available from: https://doi.org/10.1007/s12560-010-9025-6. [109] Katzenberger, R. H., Rösel, A., and Vonberg, R.-P. Bacterial survival on inanimate surfaces: a field study. [Online]. BMC Research Notes. 2021, 14(1), article no: 97 [no pagination]. [Accessed 12 March 2025]. Available from: https://doi.org/10.1186/s13104-021-05492-0. [110] Kreider, J., Curtiss, P., and Rabl, A. Heating and Cooling of Buildings: Design for Efficiency. [Online]. 3rd ed. CRC Press, 2016. [Accessed 17 March 2025]. Available from: https://doi.org/10.1201/9781315374567-24. [111] Scientific Advisory Group for Emergencies. Environmental Modelling Group: Role of ventilation in controlling SARS-CoV-2 transmission. [Online]. 2020. [Accessed 15 March 2025]. Available from: https://www.gov.uk/government/publications/emg-role-of-ventilation-in-controlling-sars-cov-2-transmission-30-september-2020. [112] Lipinski, T., Ahmad, D., Serey, N., and Jouhara, H. Review of ventilation strategies to reduce the risk of disease transmission in high occupancy buildings. [Online]. International Journal of Thermofluids. 2020, 7-8, article no: 100045 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1016/j.ijft.2020.100045. [113] Department for Levelling Up, Housing and Communities. The Building Regulations 2010. Approved Document F: Ventilation. [Online]. HM Government, 2021. [Accessed 3 December 2025]. Available from: https://www.gov.uk/government/publications/ventilation-approved-document-f. [114] Roberts, B. M., Adzic, F., Hathway, E. A., Iddon, C., Jones, B., Cook, M. J., and Malki-Epshtein, L., Measurement of ventilation effectiveness and indoor air quality in toilets at mass gathering events. In: 43rd AIVC, 11th TightVent Conference and 9th Venticool Conference 2023, 4 - 5 October 2023, Copenhagen. [Online]. AIVC, 2023, pp.575–584. [Accessed 13 March 2025]. Available from: https://www.aivc.org/resource/measurement-ventilation-effectiveness-and-indoor-air-quality-toilets-mass-gathering-events?volume=39582. [115] Lee, M. C. J. and Tham, K. W. Public toilets with insufficient ventilation present high cross infection risk. [Online]. Scientific Reports. 2021, 11(1), article no: 20623 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10.1038/s41598-021-00166-0. [116] Jung, J., Lee, J., Jo, S., Bae, S., Kim, J. Y., Cha, H. H., Lim, Y.-J., Kwak, S. H., Hong, M. J., Kim, E. O., Bae, J.-Y., Kang, C., Sung, M., Park, M.-S., and Kim, S.-H. Nosocomial Outbreak of COVID-19 in a Hematologic Ward. [Online]. Infection & Chemotherapy. 2021, 53(2), pp.332–341. [Accessed 8 March 2024]. Available from: https://doi.org/10.3947/ic.2021.0046. [117] Li, T., Katz, A., Osei-Twum, J.-A., James, L., Leung, V., Bozek, P., Persaud, N., O’Campo, P., and Siegel, J. A. Science tells us that portable air filters reduce infection risk. It’s time for public health authorities to make this clear. [Online]. Journal of Infection and Public Health. 2025, 18(3), article no: 102650 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.jiph.2024.102650. [118] Buising, K. L., Schofield, R., Irving, L., Keywood, M., Stevens, A., Keogh, N., Skidmore, G., Wadlow, I., Kevin, K., Rismanchi, B., Wheeler, A. J., Humphries, R. S., Kainer, M., Monty, J., McGain, F., and Marshall, C. Use of portable air cleaners to reduce aerosol transmission on a hospital coronavirus disease 2019 (COVID-19) ward. [Online]. Infection Control and Hospital Epidemiology. 2022, 43(8), pp.987–992. [Accessed 17 March 2025]. Available from: https://doi.org/10.1017/ice.2021.284. [119] Derk, R. C., Coyle, J. P., Lindsley, W. G., Blachere, F. M., Lemons, A. R., Service, S. K., Martin, S. B., Mead, K. R., Fotta, S. A., Reynolds, J. S., McKinney, W. G., Sinsel, E. W., Beezhold, D. H., and Noti, J. D. Efficacy of Do-It-Yourself air filtration units in reducing exposure to simulated respiratory aerosols. [Online]. Building and Environment. 2023, 229, article no: 109920 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.109920. [120] Coyle, J. P., Derk, R. C., Lindsley, W. G., Blachere, F. M., Boots, T., Lemons, A. R., Martin, S. B., Mead, K. R., Fotta, S. A., Reynolds, J. S., McKinney, W. G., Sinsel, E. W., Beezhold, D. H., and Noti, J. D. Efficacy of Ventilation, HEPA Air Cleaners, Universal Masking, and Physical Distancing for Reducing Exposure to Simulated Exhaled Aerosols in a Meeting Room. [Online]. Viruses. 2021, 13(12), article no: 2536 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.3390/v13122536. [121] Fennelly, M., Hellebust, S., Wenger, J., O’Connor, D., Griffith, G. W., Plant, B. J., and Prentice, M. B. Portable HEPA filtration successfully augments natural-ventilation-mediated airborne particle clearance in a legacy design hospital ward. [Online]. Journal of Hospital Infection. 2023, 131, pp.54–57. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j. jhin.2022.09.017. [122] Rutala, W. A., Jones, S. M., Worthington, J. M., Reist, P. C., and Weber, D. J. Efficacy of portable filtration units in reducing aerosolized particles in the size range of Mycobacterium tuberculosis. [Online]. Infection Control and Hospital Epidemiology. 1995, 16(7), pp.391–398. [Accessed 17 March 2025]. Available from: https://doi.org/10.1086/647136. [123] Conway Morris, A., Sharrocks, K., Bousfield, R., Kermack, L., Maes, M., Higginson, E., Forrest, S., Pereira-Dias, J., Cormie, C., Old, T., Brooks, S., Hamed, I., Koenig, A., Turner, A., White, P., Floto, R. A., Dougan, G., Gkrania-Klotsas, E., Gouliouris, T., Baker, S., and Navapurkar, V. The Removal of Airborne Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) and Other Microbial Bioaerosols by Air Filtration on Coronavirus Disease 2019 (COVID-19) Surge Units. [Online]. Clinical Infectious Diseases.2022, 75(1), pp.e97–e101. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/cid/ciab933. [124] Thuresson, S., Fraenkel, C. J., Sasinovich, S., Soldemyr, J., Widell, A., Medstrand, P., Alsved, M., and Löndahl, J. Airborne Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Hospitals: Effects of Aerosol-Generating Procedures, HEPA-Filtration Units, Patient Viral Load, and Physical Distance. [Online]. Clinical Infectious Diseases. 2022, 75(1), pp.e89–e96. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/cid/ciac161. [125] Ueki, H., Ujie, M., Komori, Y., Kato, T., Imai, M., and Kawaoka, Y. Effectiveness of HEPA Filters at Removing Infectious SARS-CoV-2 from the Air. [Online]. mSphere. 2022, 7(4), article no: e0008622 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1128/msphere.00086-22. [126] Myers, N. T., Laumbach, R. J., Black, K. G., Ohman-Strickland, P., Alimokhtari, S., Legard, A., De Resende, A., Calderon, L., Lu, F. T., Mainelis, G., and Kipen, H. M. Portable air cleaners and residential exposure to SARS-CoV-2 aerosols: A real-world study. [Online]. Indoor Air. 2022, 32(4), article no: e13029 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/ina.13029. [127] Boswell, T. C. and Fox, P. C. Reduction in MRSA environmental contamination with a portable HEPA-filtration unit. [Online]. The Journal of Hospital Infection. 2006, 63(1), pp.47–54. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.jhin.2005.11.011. [128] Kowalski, W. UVGI Disinfection Theory. [Online]. Springer, 2009. [Accessed 26 February 2025]. Available from: https://doi.org/10.1007/978-3-642-01999-9_2. [129] Buonanno, M., Ponnaiya, B., Welch, D., Stanislauskas, M., Randers-Pehrson, G., Smilenov, L., Lowy, F. D., Owens, D. M., and Brenner, D. J. Germicidal Efficacy and Mammalian Skin Safety of 222-nm UV Light. [Online]. Radiation research. 2017, 187(4), pp.483–491. [Accessed 26 February 2025]. Available from: https://doi.org/10.1667/RR0010CC.1. [130] Tavares, R. S. N., Adamoski, D., Girasole, A., Lima, E. N., Silva Justo-Junior, A. da, Domingues, R., Silveira, A. C. C., Marques, R. E., Carvalho, M. de, Ambrosio, A. L. B., Leme, A. F. P., and Dias, S. M. G. Different biological effects of exposure to far-UVC (222 nm) and near-UVC (254 nm) irradiation. [Online]. Journal of Photochemistry and Photobiology B: Biology. 2023, 243, article no: 112713 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.jphotobiol.2023.112713. [131] Bueno de Mesquita, P. J., Sokas, R. K., Rice, M. B., and Nardell, E. A. FarUVC: Technology Update with an Untapped Potential to Mitigate Airborne Infections. [Online]. Annals of the American Thoracic Society. 2023, 20(12), pp.1700–1702. [Accessed 26 February 2025]. Available from: https://doi.org/10.1513/AnnalsATS.202305-460VP. [132] Eadie, E., Hiwar, W., Fletcher, L., Tidswell, E., O’Mahoney, P., Buonanno, M., Welch, D., Adamson, C. S., Brenner, D. J., Noakes, C., and Wood, K. Far-UVC (222 nm) efficiently inactivates an airborne pathogen in a room sized chamber. [Online]. Scientific Reports. 2022, 12(1), article no: 4373 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10. 1038/s41598-022-08462-z. [133] Welch, D., Buonanno, M., Grilj, V., Shuryak, I., Crickmore, C., Bigelow, A. W., Randers-Pehrson, G., Johnson, G. W., and Brenner, D. J. Far-UVC light: A new tool to control the spread of airborne-mediated microbial diseases. [Online]. Scientific Reports. 2018, 8(1), article no: 2752 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1038/s41598-018-21058-w. [134] Kitagawa, H., Nomura, T., Nazmul, T., Omori, K., Shigemoto, N., Sakaguchi, T., and Ohge, H. Effectiveness of 222-nm ultraviolet light on disinfecting SARS-CoV-2 surface contamination. [Online]. American Journal of Infection Control. 2021, 49(3), pp.299–301. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2020.08.022. [135] Kaple, C. E., Memic, S., Cadnum, J. L., and Donskey, C. J. Evaluation of an automated far ultraviolet-C light technology for decontamination of surfaces and aerosolized viruses in bathrooms. [Online]. Antimicrobial Resistance & Infection Control. 2024, 13(1), article no: 114 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1186/s13756-024-01473-7. [136] Bang, J.-I., Jo, Y.-L., Lee, E.-T., and Sung, M. Far-UVC (222 nm) disinfection performance in residential spaces: Experimental study on Bacillus subtilis contamination. [Online]. Results in Engineering. 2025, 25, article no: 103642 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.rineng.2024.103642. [137] Kitagawa, H., Kaiki, Y., Tadera, K., Nomura, T., Omori, K., Shigemoto, N., Takahashi, S., and Ohge, H. Pilot study on the decontamination efficacy of an installed 222-nm ultraviolet disinfection device (Care222™), with a motion sensor, in a shared bathroom. [Online]. Photodiagnosis and Photodynamic Therapy. 2021, 34, article no: 102334 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.pdpdt.2021.102334. 138] Browne, K. and Mitchell, B. G. Multimodal environmental cleaning strategies to prevent healthcare-associated infections. [Online]. Antimicrobial Resistance & Infection Control. 2023, 12(1), article no: 83 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1186/s13756-023-01274-4. [139] Donskey, C. J. Does improving surface cleaning and disinfection reduce healthcare-associated infections? [Online]. American Journal of Infection Control. 2013, 41(5), pp.S12–S19. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2012.12.010. [140] Sassi, H. P., Reynolds, K. A., Pepper, I. L., and Gerba, C. P. Evaluation of hospital-grade disinfectants on viral deposition on surfaces after toilet flushing. [Online]. American Journal of Infection Control. 2018, 46(5), pp.507–511. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2017.11.005. [141] Kollepara, P. K., Siegenfeld, A. F., Taleb, N. N., and Bar-Yam, Y. Unmasking the mask studies: why the effectiveness of surgical masks in preventing respiratory infections has been underestimated. [Online]. Journal of Travel Medicine. 2021, article no: taab144 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1093/jtm/taab144. [142] Das, S., Sarkar, S., Das, A., Das, S., Chakraborty, P., and Sarkar, J. A comprehensive review of various categories of face masks resistant to Covid19. [Online]. Clinical Epidemiology and Global Health. 2021, 12, article no: 100835 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10.1016/j.cegh.2021.100835. [143] MacIntyre, C. R. and Chughtai, A. A. A rapid systematic review of the efficacy of face masks and respirators against coronaviruses and other respiratory transmissible viruses for the community, healthcare workers and sick patients. [Online]. International Journal of Nursing Studies. 2020, 108, article no: 103629 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1016/j.ijnurstu.2020.103629. [144] Barasheed, O., Almasri, N., Badahdah, A.-M., Heron, L., Taylor, J., McPhee, K., Ridda, I., Haworth, E., Dwyer, D. E., and Rashid, H. Pilot Randomised Controlled Trial to Test Effectiveness of Facemasks in Preventing Influenza like Illness Transmission among Australian Hajj Pilgrims in 2011. [Online]. Infectious Disorders - Drug Targets. 2014, pp.110–116. [Accessed 25 February 2025]. Available from: https://doi.org/10.2174/1871526514666141021112855. [145] Canini, L., Andréoletti, L., Ferrari, P., D’Angelo, R., Blanchon, T., Lemaitre, M., Filleul, L., Ferry, J.-P., Desmaizieres, M., Smadja, S., Valleron, A.-J., and Carrat, F. Surgical Mask to Prevent Influenza Transmission in Households: A Cluster Randomized Trial. [Online]. PLOS ONE. 2010, 5(11), article no: e13998 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1371/journal.pone.0013998. [146] Johnson, D. F., Druce, J. D., Birch, C., and Grayson, M. L. A Quantitative Assessment of the Efficacy of Surgical and N95 Masks to Filter Influenza Virus in Patients with Acute Influenza Infection. [Online]. Clinical Infectious Diseases. 2009, 49(2), pp.275–277. [Accessed 25 February 2025]. Available from: https://doi.org/10.1086/600041. [147] MacIntyre, C. R., Zhang, Y., Chughtai, A. A., Seale, H., Zhang, D., Chu, Y., Zhang, H., Rahman, B., and Wang, Q. Cluster randomised controlled trial to examine medical mask use as source control for people with respiratory illness. [Online]. BMJ Open. 2016, 6(12), article no: e012330 [no pagination]. [Accessed 25 February 2025]. Available from: https://doi.org/10.1136/bmjopen-2016-012330. [148] Liang, M., Gao, L., Cheng, C., Zhou, Q., Uy, J. P., Heiner, K., and Sun, C. Efficacy of face mask in preventing respiratory virus transmission: A systematic review and meta-analysis. [Online]. Travel Medicine and Infectious Disease. 2020, 36, article no: 101751 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.tmaid.2020.101751. [149] Jumaa, P. A. Hand hygiene: simple and complex. [Online]. International Journal of Infectious Diseases. 2005, 9(1), pp.3–14. [Accessed 26 February 2025]. Available from: https://doi.org/10.1016/j.ijid.2004.05.005. [150] Aiello, A. E., Coulborn, R. M., Perez, V., and Larson, E. L. Effect of Hand Hygiene on Infectious Disease Risk in the Community Setting: A Meta-Analysis. [Online]. American Journal of Public Health. 2008, 98(8), pp.1372–1381. [Accessed 26 February 2025]. Available from: https://doi.org/10.2105/AJPH.2007.124610. [151] Girou, E., Loyeau, S., Legrand, P., Oppein, F., and Brun-Buisson, C. Efficacy of handrubbing with alcohol based solution versus standard handwashing with antiseptic soap: randomised clinical trial. [Online]. BMJ. 2002, 325(7360), article no: 362 [no pagination]. [Accessed 26 February 2025]. Available from: https://doi.org/10.1136/bmj.325.7360.362. [152] Mouajou, V., Adams, K., DeLisle, G., and Quach, C. Hand hygiene compliance in the prevention of hospital-acquired infections: a systematic review. [Online]. The Journal of Hospital Infection. 2022, 119, pp.33–48. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.jhin.2021.09.016. [153] Sickbert-Bennett, E. E., DiBiase, L. M., Willis, T. M. S., Wolak, E. S., Weber, D. J., and Rutala, W. A. Reduction of Healthcare-Associated Infections by Exceeding High Compliance with Hand Hygiene Practices. [Online]. Emerging Infectious Diseases. 2016, 22(9), pp.1628–1630. [Accessed 26 February 2025]. Available from: https://doi.org/10.3201/eid2209.151440. [154] Gammon, J., Hunt, J., Duffy, L., Humphreys, I., Hinkin, J., and Watkins, A. Impact of an educational intervention on hand hygiene practice among nursing students, with a focus on hand drying efficacy. [Online]. Journal of Infection Prevention. 2024, 25(1), pp.3–10. [Accessed 26 February 2025]. Available from: https://doi.org/10.1177/17571774231224695. [155] Carter, W. H. Flushed: How the Plumber Saved Civilization. [Online]. Atria Books, 2006. [Accessed 17 March 2025]. Available from: https://books.google.co.uk/books?id=QiGdMafoOUkC. [156] Allen, E. and Swoboda, D. How Buildings Work: The Natural Order of Architecture. [Online]. Oxford University Press, 2005. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/oso/9780195161984.001.0001. [157] Ritchie, L. Toilet. [Online]. 2012. [Accessed 26 February 2025]. Available from: https://flic.kr/p/cSuKFf. [158] Gugleta, L. Beautiful and modern bathroom seat. [Online]. 2019. [Accessed 27 February 2025]. Available from: https://unsplash.com/photos/whiteflush-toilet-8mMUnl_exqY. [159] Acabashi. City of London Cemetery and Crematorium permissive lavatory block cubicle 1. [Online]. 2020. [Accessed 26 February 2025]. Available from: https://flic.kr/p/2jhBHfu. [160] Beltz, G. Toilet. [Online]. 2017. [Accessed 26 February 2025]. Available from: https://flic.kr/p/TV7Czj. [161] Miller, D. K. Crazy Flushmate 2. [Online]. 2008. [Accessed 26 February 2025]. Available from: https://flic.kr/p/5faAve. [162] Kecko. Swiss SBB Train Toilet. [Online]. 2010. [Accessed 26 February 2025]. Available from: https://flic.kr/p/88Aiqw. [163] United States General Accounting Office. Water Infrastructure: Water-efficient Plumbing Fixtures Reduce Water Consumption and Wastewater Flows. [Online]. 2000. [Accessed 17 March 2025]. Available from: https://www.gao.gov/assets/rced-00-232.pdf. [164] U.S. Department of Housing and Urban Development. The Rehab Guide: Kitchens & baths. [Online]. 2000. [Accessed 17 March 2025]. Available from: https://books.google.co.uk/books?id=1r86ejmwQzQC. [165] United Nations Environment Programme. Every Drop Counts: Environmentally Sound Technologies for Urban and Domestic Water Use Efficiency. [Online]. 2008. [Accessed 17 March 2025]. Available from: http://digitallibrary.un.org/record/644388. [166] Li, Y.-Y., Wang, J.-X., and Chen, X. Can a toilet promote virus transmission? From a fluid dynamics perspective. [Online]. Physics of Fluids. 2020, 32(6), article no: 065107 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1063/5.0013318. [167] LaNasa, P. J. and Upp, E. L. Basic Flow Measurement Laws. In: LaNasa, P. J. and Upp, E. L., eds. Fluid Flow Measurement. [Online]. 2nd ed. Gulf Professional Publishing, 2002, pp.19–29. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/b978-0-12-409524-3.00002-2. [168] Rapp, B. E. Fluids. In: Rapp, B. E., ed. Microfluidics: Modelling, Mechanics and Mathematics. [Online]. Elsevier, 2017, pp.243–263. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/B978-1-4557-3141-1.50009-5. [169] Dandekar, R., Shen, N., Naar, B., and Bourouiba, L. Splash on a liquid pool: coupled cavity–sheet unsteady dynamics. [Online]. Journal of Fluid Mechanics. 2025, 1002, article no: A13 [no pagination]. [Accessed 27 February 2025]. Available from: https://doi.org/10.1017/jfm.2024.1105. [170] Zhang, H., Zhang, X., Yi, X., He, F., Niu, F., and Hao, P. Effect of wettability on droplet impact: Spreading and splashing. [Online]. Experimental Thermal and Fluid Science. 2021, 124, article no: 110369 [no pagination]. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/j.expthermflusci.2021.110369. [171] Zhang, H., Su, X., Xiao, Q., and Lai, A. C. K. Experimental study on droplet and bioaerosol emissions from flushing a squat toilet. [Online]. Building and Environment. 2024, 250, p.v. [Accessed 21 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2024.111162. [172] Macher, J. M. Positive-hole correction of multiple-jet impactors for collecting viable microorganisms. [Online]. American Industrial Hygiene Association Journal. 1989, 50(11), pp.561–568. [Accessed 17 March 2025]. Available from: https://doi.org/10.1080/15298668991375164. [173] Halkman, H. B. D. and Halkman, A. K. Indicator Organisms. In: Batt, C. A. and Tortorello, M. L., eds. Encyclopedia of Food Microbiology. [Online]. 2nd ed. Academic Press, 2014, pp.358–363. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/B978-0-12-384730-0.00396-7. [174] Eden, R. ENTEROBACTERIACEAE, COLIFORMS AND E. COLI | Classical and Modern Methods for Detection and Enumeration. In: Batt, C. A. and Tortorello, M. L., eds. Encyclopedia of Food Microbiology. [Online]. 2nd ed. Academic Press, 2014, pp.667–673. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/B978-0-12-384730-0.00097-5. [175] Price, R. G., Wildeboer, D., Price, R. G., and Wildeboer, D. E. coli as an Indicator of Contamination and Health Risk in Environmental Waters. In: Escherichia coli – Recent Advances on Physiology, Pathogenesis and Biotechnological Applications. [Online]. InTech, 2017. [Accessed 27 February 2025]. Available from: https://doi.org/10.5772/67330. [176] Holcomb, D. A. and Stewart, J. R. Microbial Indicators of Fecal Pollution: Recent Progress and Challenges in Assessing Water Quality. [Online]. Current Environmental Health Reports. 2020, 7(3), pp.311–324. [Accessed 27 February 2025]. Available from: https://doi.org/10.1007/s40572-020-00278-1. [177] Riemann, H. and Cliver, D. O. Foodborne Infections and Intoxications. [Online]. 2011. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/B978-0-12-416041-5.00037-8. [178] Im, J., Nichols, C., Bjerregaard-Andersen, M., Sow, A. G., Løfberg, S., Tall, A., Pak, G. D., Aaby, P., Baker, S., Clemens, J. D., Espinoza, L. M. C., Konings, F., May, J., Monteiro, M., Niang, A., Panzner, U., Park, S. E., Schütt-Gerowitt, H., Wierzba, T. F., Marks, F., and Kalckreuth, V. von. Prevalence of Salmonella Excretion in Stool: A Community Survey in 2 Sites, Guinea-Bissau and Senegal. [Online]. Clinical Infectious Diseases. 2016, 62, pp.S50–S55. [Accessed 27 February 2025]. Available from: https://doi.org/10.1093/cid/civ789. [179] Hale, T. L. and Keusch, G. T. Medical Microbiology. [Online]. 4th ed. University of Texas Medical Branch at Galveston, 1996. [Accessed 27 February 2025]. Available from: https://www.ncbi.nlm.nih.gov/books/NBK7627/. [180] Guh, A. Y. and Kutty, P. K. Clostridioides difficile Infection. [Online]. Annals of Internal Medicine. 2018, 169(7), pp.ITC49–ITC64. [Accessed 27 February 2025]. Available from: https://doi.org/10.7326/AITC201810020. [181] Lee, N., Chan, M. C. W., Wong, B., Choi, K. W., Sin, W., Lui, G., Chan, R. C. W., Lai, R. W. M., Cockram, C. S., Sung, J. J. Y., and Leung, W. K. Fecal Viral Concentration and Diarrhea in Norovirus Gastroenteritis. [Online]. Emerging Infectious Diseases. 2007, 13(9), pp.1399–1401. [Accessed 25 January 2024]. Available from: https://doi.org/10.3201/eid1309.061535. [182] Brown, D. M., Butler, D., Orman, N. R., and Davies, J. W. Gross solids transport in small diameter sewers. [Online]. Water Science and Technology. 1996, 33(9), pp.25–30. [Accessed 26 January 2024]. Available from: https://doi.org/10.1016/0273-1223(96)00366-6. [183] Flewett, T. H. Rotavirus in the home and hospital nursery. [Online]. British Medical Journal (Clinical Research Ed.) 1983, 287(6392), pp.568–569. [Accessed 17 March 2025]. Available from: https://doi.org/10.1136/bmj.287.6392.568. [184] Dennehy, P. H. Transmission of rotavirus and other enteric pathogens in the home. [Online]. The Pediatric Infectious Disease Journal. 2000, 19(10), S103–S105. [Accessed 27 February 2025]. Available from: https://doi.org/10.1097/00006454-200010001-00003. [185] Zhu, N., Zhang, D., Wang, W., Li, X., Yang, B., Song, J., Zhao, X., Huang, B., Shi, W., Lu, R., Niu, P., Zhan, F., Ma, X., Wang, D., Xu, W., Wu, G., Gao, G. F., and Tan, W. A Novel Coronavirus from Patients with Pneumonia in China, 2019. [Online]. New England Journal of Medicine. 2020, 382(8), pp.727–733. [Accessed 15 January 2025]. Available from: https://doi.org/10.1056/NEJMoa2001017. [186] Foladori, P., Cutrupi, F., Segata, N., Manara, S., Pinto, F., Malpei, F., Bruni, L., and La Rosa, G. SARS-CoV-2 from faeces to wastewater treatment: What do we know? A review. [Online]. Science of The Total Environment. 2020, 743, article no: 140444 [no pagination]. [Accessed 23 January 2024]. Available from: https://doi.org/10.1016/j.scitotenv.2020.140444. [187] Dada, A. C. and Gyawali, P. Quantitative microbial risk assessment (QMRA) of occupational exposure to SARS-CoV-2 in wastewater treatment plants. [Online]. Science of The Total Environment. 2021, 763, article no: 142989 [no pagination]. [Accessed 12 January 2024]. Available from: https://doi.org/10.1016/j.scitotenv.2020.142989. [188] Barroso-Arévalo, S., Rivera, B., Domínguez, L., and Sánchez-Vizcaíno, J. M. First Detection of SARS-CoV-2 B.1.1.7 Variant of Concern in an Asymptomatic Dog in Spain. [Online]. Viruses. 2021, 13(7), article no: 1379 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.3390/v13071379. [189] Gortázar, C., Barroso-Arévalo, S., Ferreras-Colino, E., Isla, J., Fuente, G. d. l., Rivera, B., Domínguez, L., Fuente, J. d. l., and Sánchez-Vizcaíno, J. M. Natural SARS-CoV-2 Infection in Kept Ferrets, Spain. [Online]. Emerging Infectious Diseases. 2021, 27(7), article no: 1994 [no pagination]. [Accessed 19 November 2024]. Available from: https://doi.org/10.3201/eid2707.210096. [190] Dergham, J., Delerce, J., Bedotto, M., La Scola, B., and Moal, V. Isolation of Viable SARS-CoV-2 Virus from Feces of an Immunocompromised Patient Suggesting a Possible Fecal Mode of Transmission. [Online]. Journal of Clinical Medicine. 2021, 10(12), article no: 2696 [no pagination]. [Accessed 19 November 2024]. Available from: https://doi.org/10.3390/jcm10122696. [191] Zhou, J., Li, C., Liu, X., Chiu, M. C., Zhao, X., Wang, D., Wei, Y., Lee, A., Zhang, A. J., Chu, H., Cai, J.-P., Yip, C. C.-Y., Chan, I. H.-Y., Wong, K. K.-Y., Tsang, O. T.-Y., Chan, K.-H., Chan, J. F.-W., To, K. K.-W., Chen, H., and Yuen, K. Y. Infection of bat and human intestinal organoids by SARS-CoV-2. [Online]. Nature Medicine. 2020, 26(7), pp.1077–1083. [Accessed 17 March 2025]. Available from: https://doi.org/10.1038/s41591-020-0912-6. [192] Yao, H., Lu, X., Chen, Q., Xu, K., Chen, Y., Cheng, L., Liu, F., Wu, Z., Wu, H., Jin, C., Zheng, M., Wu, N., Jiang, C., and Li, L. Patient-derived mutations impact pathogenicity of SARS-CoV-2. [Online]. 2020. [Accessed 19 November 2024]. Available from: https://doi.org/10.1101/2020.04.14.20060160. [193] Das Adhikari, U., Eng, G., Farcasanu, M., Avena, L. E., Choudhary, M. C., Triant, V. A., Flagg, M., Schiff, A. E., Gomez, I., Froehle, L. M., Diefenbach, T. J., Ronsard, L., Lingwood, D., Lee, G. C., Rabi, S. A., Erstad, D., Velmahos, G., Li, J. Z., Hodin, R., Stone, J. R., Honko, A. N., Griffiths, A., Yilmaz, Ö. H., and Kwon, D. S. Fecal Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-Cov-2) RNA Is Associated With Decreased Coronavirus Disease 2019 (COVID-19) Survival. [Online]. Clinical Infectious Diseases. 2022, 74(6), pp.1081–1084. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/cid/ciab623. [194] Audsley, J. M., Holmes, N. E., Mordant, F. L., Douros, C., Zufan, S. E., Nguyen, T. H. O., Kedzierski, L., Rowntree, L. C., Hensen, L., Subbarao, K., Kedzierska, K., Nicholson, S., Sherry, N., Thevarajan, I., Tran, T., and Druce, J. Temporal differences in culturable severe acute respiratory coronavirus virus 2 (SARS-CoV-2) from the respiratory and gastrointestinal tracts in a patient with moderate coronavirus disease 2019 (COVID-19). [Online]. Infection Control and Hospital Epidemiology. 2022, 43(9), pp.1286–1288. [Accessed 17 March 2025]. Available from: https://doi.org/10.1017/ice.2021.223. [195] Jeong, H. W., Kim, S.-M., Kim, H.-S., Kim, Y.-I., Kim, J. H., Cho, J. Y., Kim, S.-h., Kang, H., Kim, S.-G., Park, S.-J., Kim, E.-H., and Choi, Y. K. Viable SARS-CoV-2 in various specimens from COVID-19 patients. [Online]. Clinical Microbiology and Infection. 2020, 26(11), pp.1520–1524. [Accessed 19 November 2024]. Available from: https://doi.org/10.1016/j.cmi.2020.07.020. [196] Jiao, L., Li, H., Xu, J., Yang, M., Ma, C., Li, J., Zhao, S., Wang, H., Yang, Y., Yu, W., Wang, J., Yang, J., Long, H., Gao, J., Ding, K., Wu, D., Kuang, D., Zhao, Y., Liu, J., Lu, S., Liu, H., and Peng, X. The Gastrointestinal Tract Is an Alternative Route for SARS-CoV-2 Infection in a Nonhuman Primate Model. [Online]. Gastroenterology. 2021, 160(5), pp.1647–1661. [Accessed 17 March 2025]. Available from: https://doi.org/10.1053/j.gastro.2020.12.001. [197] Xiao, F., Sun, J., Xu, Y., Li, F., Huang, X., Li, H., Zhao, J., Huang, J., and Zhao, J. Infectious SARS-CoV-2 in Feces of Patient with Severe COVID-19. [Online]. Emerging Infectious Diseases. 2020, 26(8), pp.1920–1922. [Accessed 17 March 2025]. Available from: https://doi.org/10.3201/eid2608.200681. [198] Bartlett, S. L., Diel, D. G., Wang, L., Zec, S., Laverack, M., Martins, M., Caserta, L. C., Killian, M. L., Terio, K., Olmstead, C., Delaney, M. A., Stokol, T., Ivančić, M., Jenkins-Moore, M., Ingerman, K., Teegan, T., McCann, C., Thomas, P., McAloose, D., Sykes, J. M., and Calle, P. P. SARS-CoV-2 Infection And Longitudinal Fecal Screening In Malayan Tigers (Panthera tigris jacksoni), Amur Tigers (Panthera tigris altaica), And African Lions (Panthera leo krugeri) At The Bronx Zoo, New York, USA. [Online]. Journal of Zoo and Wildlife Medicine. 2021, 51(4), pp.733–744. [Accessed 17 March 2025]. Available from: https://doi.org/10.1638/2020-0171. [199] Wang, W., Xu, Y., Gao, R., Lu, R., Han, K., Wu, G., and Tan, W. Detection of SARS-CoV-2 in Different Types of Clinical Specimens. [Online]. JAMA. 2020, 323(18), article no: 1843 [no pagination]. [Accessed 19 November 2024]. Available from: https://doi.org/10.1001/jama.2020.3786. [200] Zhang, Y., Chen, C., Song, Y., Zhu, S., Wang, D., Zhang, H., Han, G., Weng, Y., Xu, J., Xu, J., Yu, P., Jiang, W., Yang, X., Lang, Z., Yan, D., Wang, Y., Song, J., Gao, G. F., Wu, G., and Xu, W. Excretion of SARS-CoV-2 through faecal specimens. [Online]. Emerging Microbes & Infections. 2020, 9(1), pp.2501–2508. [Accessed 17 March 2025]. Available from: https://doi.org/10.1080/22221751.2020.1844551. [201] Riley, E. C., Murphy, G., and Riley, R. L. Airborne spread of measles in a suburban elementary school. [Online]. American Journal of Epidemiology. 1978, 107(5), pp.421–432. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/oxfordjournals.aje.a112560. [202] Buonanno, G., Stabile, L., and Morawska, L. Estimation of airborne viral emission: Quanta emission rate of SARS-CoV-2 for infection risk assessment. [Online]. Environment International. 2020, 141, article no: 105794 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10. 1016/j.envint.2020.105794. [203] Noakes, C. J. and Sleigh, A., Applying the Wells-Riley equation to the risk of airborne infection in hospital environments: The importance of stochastic and proximity effects. In: Indoor Air 2008: the 11th International Conference on Indoor Air Quality and Climate, 17 - 18 August 2008, Copenhagen. [Online]. ISIAQ, 2008, pp.161–168. [Accessed 15 March 2025]. Available from: https://eprints.whiterose.ac.uk/7702/1/Noakes-indoorair2008.pdf. [204] Edwards, A. J., King, M.-F., Noakes, C. J., Peckham, D., and López-García, M. The Wells–Riley model revisited: Randomness, heterogeneity, and transient behaviours. [Online]. Risk Analysis. 2024, 44(9), pp.2125–2147. [Accessed 28 February 2025]. Available from: https://doi.org/10.1111/risa.14295. [205] Gammaitoni, L. and Nucci, M. C. Using a mathematical model to evaluate the efficacy of TB control measures. [Online]. Emerging Infectious Diseases. 1997, 3(3), pp.335–342. [Accessed 28 February 2025]. Available from: https://doi.org/10.3201/eid0303.970310. [206] Nardell, E. A., Keegan, J., Cheney, S. A., and Etkind, S. C. Airborne infection. Theoretical limits of protection achievable by building ventilation. [Online]. The American Review of Respiratory Disease. 1991, 144(2), pp.302–306. [Accessed 17 March 2025]. Available from: https://doi.org/10.1164/ajrccm/144.2.302. [207] Escombe, A. R., Oeser, C. C., Gilman, R. H., Navincopa, M., Ticona, E., Pan, W., Martínez, C., Chacaltana, J., Rodríguez, R., Moore, D. A. J., Friedland, J. S., and Evans, C. A. Natural Ventilation for the Prevention of Airborne Contagion. [Online]. PLOS Medicine. 2007, 4(2), article no: e68 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1371/journal.pmed.0040068. [208] Gao, N. P., Niu, J. L., Perino, M., and Heiselberg, P. The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation. [Online]. Building and Environment. 2008, 43(11), pp.1805–1817. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2007.10.023. [209] Qian, H., Li, Y., Nielsen, P. V., and Huang, X. Spatial distribution of infection risk of SARS transmission in a hospital ward. [Online]. Building and Environment. 2009, 44(8), pp.1651–1658. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2008.11.002. [210] Tung, Y.-C. and Hu, S.-C. Infection Risk of Indoor Airborne Transmission of Diseases in Multiple Spaces. [Online]. Architectural Science Review. 2008, 51(1), pp.14–20. [Accessed 28 February 2025]. Available from: https://doi.org/10.3763/asre.2008.5103. [211] Wang, Z., Galea, E. R., Grandison, A., Ewer, J., and Jia, F. A coupled Computational Fluid Dynamics and Wells-Riley model to predict COVID-19 infection probability for passengers on long-distance trains. [Online]. Safety Science. 2022, 147, article no: 105572 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.ssci.2021.105572. [212] Pantelic, J. and Tham, K. W. Assessment of the mixing air delivery system ability to protect occupants from the airborne infectious disease transmission using Wells–Riley approach. [Online]. HVAC&R Research. 2012, 18(4), pp.562–574. [Accessed 28 February 2025]. Available from: https://doi.org/10.1080/10789669.2012.647230. [213] Guo, Y., Qian, H., Sun, Z., Cao, J., Liu, F., Luo, X., Ling, R., Weschler, L. B., Mo, J., and Zhang, Y. Assessing and controlling infection risk with Wells-Riley model and spatial flow impact factor (SFIF). [Online]. Sustainable Cities and Society. 2021, 67, article no: 102719 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.scs.2021.102719. [214] Lau, Z., Griffiths, I. M., English, A., and Kaouri, K. Predicting the spatiotemporal infection risk in indoor spaces using an efficient airborne transmission model. [Online]. Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences. 2022, 478(2259), article no: 20210383 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1098/rspa.2021.0383. [215] Ding, S., Lee, J. S., Mohamed, M. A., and Ng, B. F. Infection risk of SARSCoV-2 in a dining setting: Deposited droplets and aerosols. [Online]. Building and Environment. 2022, 213, article no: 108888 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.108888. [216] Li, J., Cheng, Z., Zhang, Y., Mao, N., Guo, S., Wang, Q., Zhao, L., and Long, E. Evaluation of infection risk for SARS-CoV-2 transmission on university campuses. [Online]. Science and Technology for the Built Environment. 2021, 27(9), pp.1165–1180. [Accessed 28 February 2025]. Available from: https://doi.org/10.1080/23744731.2021.1948762. [217] Li, H., Shankar, S. N., Witanachchi, C. T., Lednicky, J. A., Loeb, J. C., Alam, M. M., Fan, Z. H., Mohamed, K., Eiguren-Fernandez, A., and Wu, C.-Y. Environmental Surveillance and Transmission Risk Assessments for SARS-CoV-2 in a Fitness Center. [Online]. Aerosol and Air Quality Research. 2021, 21(11), article no: 210106 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.4209/aaqr.210106. [218] Timpitak, W. and Pochai, N. A Mathematical Model of Risk Assessment on Airborne Infection in a Room with an Outlet Ventilation System. [Online]. Engineering Letters. 2022, 30(2). [Accessed 19 January 2025]. Available from: https://www.engineeringletters.com/issues_v30/issue_2/EL_30_2_56.pdf. [219] Boonmeemapasuk, W. and Pochai, N. A Risk Model of Airborne Transmission and Vaccine Efficacy in an Outpatient Room with a Ventilation System. [Online]. Engineering Letters. 2022, 30(2). [Accessed 17 March 2025]. Available from: https://www.engineeringletters.com/issues_v30/issue_2/EL_30_2_28.pdf. [220] Wood, S. G. A., Craske, J., and Burridge, H. C. Relating quanta conservation and compartmental epidemiological models of airborne disease outbreaks in buildings. [Online]. Scientific Reports. 2023, 13(1), article no: 17335 [no pagination]. [Accessed 28 February 2025]. Available from: https://doi.org/10.1038/s41598-023-44527-3. [221] Haas, C. N., Rose, J. B., and Gerba, C. P. Quantitative Microbial Risk Assessment. [Online]. Wiley, 1999. [Accessed 18 March 2025]. Available from: https://books.google.co.uk/books?id=vjVhhwQh9N8C. [222] Rose, J. B., Haas, C. N., and Regli, S. Risk assessment and control of waterborne giardiasis. [Online]. American Journal of Public Health. 1991, 81(6), pp.709–713. [Accessed 28 February 2025]. Available from: https://doi.org/10.2105/ajph.81.6.709. [223] Schmid-Hempel, P. Immune defence, parasite evasion strategies and their relevance for ‘macroscopic phenomena’ such as virulence. [Online]. Philosophical Transactions of the Royal Society B: Biological Sciences. 2009, 364(1513), pp.85–98. [Accessed 28 February 2025]. Available from: https://doi.org/10.1098/rstb.2008.0157. [224] Haas, C. N. Estimation of risk due to low doses of microorganisms: a comparison of alternative methodologies. [Online]. American Journal of Epidemiology. 1983, 118(4), pp.573–582. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/oxfordjournals.aje.a113662. [225] Sze To, G. N. and Chao, C. Y. H. Review and comparison between the Wells-Riley and dose-response approaches to risk assessment of infectious respiratory diseases. [Online]. Indoor Air. 2010, 20(1), pp.2–16. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/j.1600-0668.2009.00621.x. [226] Williams, M. S., Baker, M. R., Guina, T., Hewitt, J. A., Lanning, L., Hill, H., May, J. M., Fogtman, B., and Pittman, P. R. Retrospective Analysis of Pneumonic Tularemia in Operation Whitecoat Human Subjects: Disease Progression and Tetracycline Efficacy. [Online]. Frontiers in Medicine. 2019, 6, article no: 229 [no pagination]. [Accessed 13 March 2025]. Available from: https://doi.org/10.3389/fmed.2019.00229. [227] Killingley, B., Mann, A. J., Kalinova, M., Boyers, A., Goonawardane, N., Zhou, J., Lindsell, K., Hare, S. S., Brown, J., Frise, R., Smith, E., Hopkins, C., Noulin, N., Löndt, B., Wilkinson, T., Harden, S., McShane, H., Baillet, M., Gilbert, A., Jacobs, M., Charman, C., Mande, P., Nguyen-Van-Tam, J. S., Semple, M. G., Read, R. C., Ferguson, N. M., Openshaw, P. J., Rapeport, G., Barclay, W. S., Catchpole, A. P., and Chiu, C. Safety, tolerability and viral kinetics during SARS-CoV-2 human challenge in young adults. [Online]. Nature Medicine. 2022, 28(5), pp.1031–1041. [Accessed 15 January 2025]. Available from: https://doi.org/10.1038/s41591-022-01780-9. [228] McCullogh, N. B. and Eisele, C. W. Experimental human salmonellosis. I. Pathogenicity of strains of Salmonella meleagridis and Salmonella anatum obtained from spray-dried whole egg. [Online]. The Journal of Infectious Diseases. 1951, 88(3), pp.278–289. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/infdis/88.3.278. [229] DuPont, H. L., Hornick, R. B., Dawkins, A. T., Snyder, M. J., and Formal, S. B. The Response of Man to Virulent Shigella flexneri 2a. [Online]. The Journal of Infectious Diseases. 1969, 119(3), pp.296–299. [Accessed 3 March 2025]. Available from: https://doi.org/10.1093/infdis/119.3.296. [230] Ward, R. L., Bernstein, D. I., Young, E. C., Sherwood, J. R., Knowlton, D. R., and Schiff, G. M. Human rotavirus studies in volunteers: determination of infectious dose and serological response to infection. [Online]. The Journal of Infectious Diseases. 1986, 154(5), pp.871–880. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/infdis/154.5.871. [231] Zhang, X. and Wang, J. Dose-response Relation Deduced for Coronaviruses From Coronavirus Disease 2019, Severe Acute Respiratory Syndrome, and Middle East Respiratory Syndrome: Meta-analysis Results and its Application for Infection Risk Assessment of Aerosol Transmission. [Online]. Clinical Infectious Diseases. 2021, 73(1), pp.e241–e245. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/cid/ciaa1675. [232] Dediego, M. L., Pewe, L., Alvarez, E., Rejas, M. T., Perlman, S., and Enjuanes, L. Pathogenicity of severe acute respiratory coronavirus deletion mutants in hACE-2 transgenic mice. [Online]. Virology. 2008, 376(2), pp.379–389. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.virol.2008.03.005. [233] Koprowski, H. Immunization against poliomyelitis with living attenuated virus. [Online]. The American Journal of Tropical Medicine and Hygiene. 1956, 5(3), pp.440–452. [Accessed 17 March 2025]. Available from: https://doi.org/10.4269/ajtmh.1956.5.440. [234] Cliver, D. O. Experimental Infection by Waterborne Enteroviruses. [Online]. Journal of Food Protection. 1981, 44(11), pp.861–865. [Accessed 17 March 2025]. Available from: https://doi.org/10.4315/0362-028X-44.11.861. [235] Toth, D. J. A., Gundlapalli, A. V., Schell, W. A., Bulmahn, K., Walton, T. E., Woods, C. W., Coghill, C., Gallegos, F., Samore, M. H., and Adler, F. R. Quantitative models of the dose-response and time course of inhalational anthrax in humans. [Online]. PLoS pathogens. 2013, 9(8), article no: e1003555 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1371/journal.ppat.1003555. [236] Murphy, B. R., Clements, M. L., Madore, H. P., Steinberg, J., O’Donnell, S., Betts, R., Demico, D., Reichman, R. C., Dolin, R., and Maassab, H. F. Dose Response of Cold-Adapted, Reassortant Influenza A/California/10/78 Virus (H1N1) in Adult Volunteers. [Online]. The Journal of Infectious Diseases. 1984, 149(5), p.816. [Accessed 15 January 2025]. Available from: https://doi.org/10.1093/infdis/149.5.816. [237] Hendley, J. O., Edmondson, W. P., and Gwaltney, J. M. Relation between naturally acquired immunity and infectivity of two rhinoviruses in volunteers. [Online]. The Journal of Infectious Diseases. 1972, 125(3), pp.243–248. [Accessed 17 March 2025]. Available from: https://doi.org/10.1093/infdis/125.3.243. [238] DuPont, H. L., Formal, S. B., Hornick, R. B., Snyder, M. J., Libonati, J. P., Sheahan, D. G., LaBrec, E. H., and Kalas, J. P. Pathogenesis of Escherichia coli diarrhea. [Online]. The New England Journal of Medicine. 1971, 285(1), pp.1–9. [Accessed 17 March 2025]. Available from: https://doi.org/10.1056/NEJM197107012850101. [239] Allen, L. J. S. An introduction to stochastic processes with applications to biology. [Online]. 2nd ed. CRC Press, 2003. [Accessed 15 January 2025]. Available from: https://doi.org/10.1201/b12537. [240] King, M.-F., Noakes, C. J., and Sleigh, P. A. Modeling environmental contamination in hospital single- and four-bed rooms. [Online]. Indoor Air. 2015, 25(6), pp.694–707. [Accessed 15 January 2025]. Available from: https://doi.org/10.1111/ina.12186. [241] Pessoa-Silva, C. L., Dharan, S., Hugonnet, S., Touveneau, S., Posfay-Barbe, K., Pfister, R., and Pittet, D. Dynamics of bacterial hand contamination during routine neonatal care. [Online]. Infection Control and Hospital Epidemiology. 2004, 25(3), pp.192–197. [Accessed 17 March 2025]. Available from: https://doi.org/10.1086/502376. [242] Wilson, A. M., Mussio, I., Verhougstraete, M. P., Jung, Y., Ashraf, A., Chilton, S., and Hamilton, K. A. A risk-risk tradeoff approach for incorporating the public’s risk perceptions into quantitative microbial risk assessment. [Online]. Journal of Occupational and Environmental Hygiene. 2025, 0(0), pp.1–17. [Accessed 20 January 2025]. Available from: https://doi.org/10.1080/15459624.2024.2423756. [243] Environmental Protection Agency (EPA). National primary drinking water regulations: Long Term 1 Enhanced Surface Water Treatment Rule. Final rule. [Online]. Federal Register. 2002, 67(9), pp.1811–1844. [Accessed 17 March 2025]. Available from: https://www.federalregister.gov/d/02-409. [244] Reynolds, K. A., Verhougstraete, M. P., Mena, K. D., Sattar, S. A., Scott, E. A., and Gerba, C. P. Quantifying pathogen infection risks from household laundry practices. [Online]. Journal of Applied Microbiology. 2022, 132(2), pp.1435–1448. [Accessed 20 January 2025]. Available from: https://doi.org/10.1111/jam.15273. [245] Ryan, M. O., Haas, C. N., Gurian, P. L., Gerba, C. P., Panzl, B. M., and Rose, J. B. Application of quantitative microbial risk assessment for selection of microbial reduction targets for hard surface disinfectants. [Online]. American Journal of Infection Control. 2014, 42(11), pp.1165–1172. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2014.07.024. [246] King, M.-F., Wilson, A. M., Weir, M. H., López-García, M., Proctor, J., Hiwar, W., Khan, A., Fletcher, L. A., Sleigh, P. A., Clifton, I., Dancer, S. J., Wilcox, M., Reynolds, K. A., and Noakes, C. J. Modeling fomite-mediated SARS-CoV-2 exposure through personal protective equipment doffing in a hospital environment. [Online]. Indoor Air. 2022, 32(1), article no: e12938 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/ina.12938. [247] Mizukoshi, A., Nakama, C., Okumura, J., and Azuma, K. Assessing the risk of COVID-19 from multiple pathways of exposure to SARS-CoV-2: Modeling in health-care settings and effectiveness of nonpharmaceutical interventions. [Online]. Environment International. 2021, 147, article no: 106338 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.envint.2020.106338. [248] Schijven, J. F., Wind, M., Todt, D., Howes, J., Tamele, B., and Steinmann, E. Risk assessment of banknotes as a fomite of SARS-CoV-2 in cash payment transactions. [Online]. Risk Analysis. 2023, 43(4), pp.700–708. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/risa.13935. [249] Zhang, X., Wu, J., Smith, L. M., Li, X., Yancey, O., Franzblau, A., Dvonch, J. T., Xi, C., and Neitzel, R. L. Monitoring SARS-CoV-2 in air and on surfaces and estimating infection risk in buildings and buses on a university campus. [Online]. Journal of Exposure Science & Environmental Epidemiology. 2022, 32(5), pp.751–758. [Accessed 1 March 2025]. Available from: https://doi.org/10.1038/s41370-022-00442-9. [250] Bate, A. M., Miller, D., King, M.-F., Moseley, K.-A., Xu, J., Hall, I., López-García, M., Parker, S. T., and Noakes, C. J. A quantitative microbial risk assessment approach to estimate exposure to SARS-CoV-2 on a bus. [Online]. Journal of Transport & Health. 2024, 38, article no: 101829 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.jth.2024.101829. [251] Wilson, A. M., Reynolds, K. A., Sexton, J. D., and Canales, R. A. Modeling Surface Disinfection Needs To Meet Microbial Risk Reduction Targets. [Online]. Applied and Environmental Microbiology. 2018, 84(18), article no: e00709–18 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1128/AEM.00709-18. [252] Wilson, A. M., Reynolds, K. A., and Canales, R. A. Estimating the effect of hand hygiene compliance and surface cleaning timing on infection risk reductions with a mathematical modeling approach. [Online]. American Journal of Infection Control. 2019, 47(12), pp.1453–1459. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.ajic.2019.05.023. [253] Wilson, A. M., King, M.-F., López-García, M., Clifton, I. J., Proctor, J., Reynolds, K. A., and Noakes, C. J. Effects of patient room layout on viral accruement on healthcare professionals’ hands. [Online]. Indoor Air. 2021, 31(5), pp.1657–1672. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/ina.12834. [254] Armstrong, T. W. and Haas, C. N. A Quantitative Microbial Risk Assessment Model for Legionnaires’ Disease: Animal Model Selection and Dose Response Modeling. [Online]. Risk Analysis. 2007, 27(6), pp.1581–1596. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/j.1539-6924.2007.00990.x. [255] Madera-García, V., Mraz, A. L., Lopez-Galvez, N., Weir, M. H., Werner, J., Beamer, P. I., and Verhougstraete, M. P. Legionella pneumophila as a Health Hazard to Miners: A Pilot Study of Water Quality and QMRA. [Online]. Water. 2019, 11(8), article no: 1528 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.3390/w11081528. [256] Pepper, I. L. and Gerba, C. P. Risk of infection from Legionella associated with spray irrigation of reclaimed water. [Online]. Water Research. 2018, 139, pp.101–107. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.watres.2018.04.001. [257] Xu, P.-C., Zhang, C.-M., and Wang, X. C. Numerical simulation for spatial distribution of water aerosol produced from nozzle spray and health risk related to Legionella pneumophila in spray scenarios. [Online]. Water Research. 2022, 216, article no: 118304 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.watres.2022.118304. [258] Hamilton, K. A., Kuppravalli, A., Heida, A., Joshi, S., Haas, C. N., Verhougstraete, M., and Gerrity, D. Legionnaires’ disease in dental offices: Quantifying aerosol risks to dental workers and patients. [Online]. Journal of Occupational and Environmental Hygiene. 2021, 18(8), pp.378–393. [Accessed 1 March 2025]. Available from: https://doi.org/10.1080/15459624.2021.1939878. [259] Hamilton, K. A., Hamilton, M. T., Johnson, W., Jjemba, P., Bukhari, Z., LeChevallier, M., and Haas, C. N. Health risks from exposure to Legionella in reclaimed water aerosols: Toilet flushing, spray irrigation, and cooling towers. [Online]. Water Research. 2018, 134, pp.261–279. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.watres.2017.12.022. [260] Hamilton, K. A., Hamilton, M. T., Johnson, W., Jjemba, P., Bukhari, Z., LeChevallier, M., Haas, C. N., and Gurian, P. L. Risk-Based Critical Concentrations of Legionella pneumophila for Indoor Residential Water Uses. [Online]. Environmental Science & Technology. 2019, 53(8), pp.4528–4541. [Accessed 17 March 2025]. Available from: https://doi.org/10.1021/acs.est.8b03000. [261] Ahmed, W., Vieritz, A., Goonetilleke, A., and Gardner, T. Health risk from the use of roof-harvested rainwater in Southeast Queensland, Australia, as potable or nonpotable water, determined using quantitative microbial risk assessment. [Online]. Applied and Environmental Microbiology. 2010, 76(22), pp.7382–7391. [Accessed 17 March 2025]. Available from: https://doi.org/10.1128/AEM.00944-10. [262] Blanky, M., Sharaby, Y., Rodríguez-Martínez, S., Halpern, M., and Friedler, E. Greywater reuse - Assessment of the health risk induced by Legionella pneumophila. [Online]. Water Research. 2017, 125, pp.410–417. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.watres.2017. 08.068. [263] Bouwknegt, M., Schijven, J. F., Schalk, J. A. C., and Roda Husman, A. M. de. Quantitative risk estimation for a Legionella pneumophila infection due to whirlpool use. [Online]. Risk Analysis. 2013, 33(7), pp.1228–1236. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/j.1539-6924.2012.01909.x. [264] Chen, M., Shi, L., Liu, G., Wu, X., and Lu, Y. Aerosol exposure assessment during reclaimed water utilization in China and risk evaluation in case of Legionella. [Online]. Frontiers of Environmental Science & Engineering. 2021, 16(7), article no: 95 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1007/s11783-021-1516-1. [265] Kusumawardhana, A., Zlatanovic, L., Bosch, A., and Hoek, J. P. van der. Microbiological Health Risk Assessment of Water Conservation Strategies: A Case Study in Amsterdam. [Online]. International Journal of Environmental Research and Public Health. 2021, 18(5), article no: 2595 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.3390/ijerph18052595. [266] Massiot, G., Courault, D., Jacob, P., and Albert, I. Monitoring the risk of Legionella infection using a general Bayesian network updated from temporal measurements in agricultural irrigation with reclaimed wastewater. [Online]. Environmental Science: Water Research & Technology. 2022, 9(1), pp.176–192. [Accessed 1 March 2025]. Available from: https://doi.org/10.1039/D2EW00311B. [267] Ali, W., Yang, Y.-f., Gong, L., Yan, C., and Cui, B.-b. Emission characteristics and quantitative health risk assessment of bioaerosols in an indoor toilet after flushing under various ventilation scenarios. [Online]. Building and Environment. 2022, 207, article no: 108463 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2021.108463. [268] Chen, Y.-h., Yan, C., Yang, Y.-f., and Ma, J.-x. Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants. [Online]. The Science of the Total Environment. 2021, 755, article no: 142615 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.scitotenv.2020.142615. [269] Ma, J., An, D., Cui, B., Liu, M., Zhu, H., Li, M., Ai, X., Ali, W., and Yan, C. What are the disease burden and its sensitivity analysis of workers exposing to Staphylococcus aureus bioaerosol during warm and cold periods in a wastewater treatment plant? [Online]. Environmental Science and Pollution Research. 2022, 29(55), pp.82938–82947. [Accessed 1 March 2025]. Available from: https://doi.org/10.1007/s11356-022-21447-9. [270] Wu, J.-t., Song, X.-q., Liang, L.-w., and Yan, C. Estimating acceptable exposure time for bioaerosols emission in a wastewater treatment plant by reverse quantitative microbial risk assessment based on various risk benchmarks. [Online]. Environmental Science and Pollution Research. 2022, 29(9), pp.13345–13355. [Accessed 1 March 2025]. Available from: https://doi.org/10.1007/s11356-021-16699-w. [271] Yan, C., Leng, Y.-L., and Wu, J.-T. Quantitative microbial risk assessment for occupational health of temporary entrants and staffs equipped with various grade PPE and exposed to microbial bioaerosols in two WWTPs. [Online]. International Archives of Occupational and Environmental Health. 2021, 94(6), pp.1327–1343. [Accessed 17 March 2025]. Available from: https://doi.org/10.1007/s00420-021-01663-5. [272] Yan, C., Zhao, X.-y., Luo, X., An, D.-z., Zhu, H., Li, M., Ai, X.-j., and Ali, W. Quantitative microbial risk assessment with nasal/oral breathing pattern for S. aureus bioaerosol emission from aeration tanks and residual sludge storage yard in a wastewater treatment plant. [Online]. Environmental Science and Pollution Research. 2023, 30(8), pp.21252–21262. [Accessed 1 March 2025]. Available from: https://doi.org/10.1007/s11356-022-23621-5. [273] Dean, K. and Mitchell, J. Reverse QMRA for Pseudomonas aeruginosa in Premise Plumbing to Inform Risk Management. [Online]. Journal of Environmental Engineering. 2020, 146(3). [Accessed 1 March 2025]. Available from: https://doi.org/10.1061/(ASCE)EE.1943-7870.0001641. [274] Augenbraun, B. L., Lasner, Z. D., Mitra, D., Prabhu, S., Raval, S., Sawaoka, H., and Doyle, J. M. Assessment and mitigation of aerosol airborne SARSCoV-2 transmission in laboratory and office environments. [Online]. Journal of Occupational and Environmental Hygiene. 2020, 17(10), pp.447–456. [Accessed 17 March 2025]. Available from: https://doi.org/10.1080/15459624.2020.1805117. [275] Wagner, J., Sparks, T. L., Miller, S., Chen, W., Macher, J. M., and Waldman, J. M. Modeling the impacts of physical distancing and other exposure determinants on aerosol transmission. [Online]. Journal of Occupational and Environmental Hygiene. 2021, 18(10), pp.495–509. [Accessed 1 March 2025]. Available from: https://doi.org/10.1080/15459624.2021.1963445. [276] Bale, R., Iida, A., Yamakawa, M., Li, C., and Tsubokura, M. Quantifying the COVID19 infection risk due to droplet/aerosol inhalation. [Online]. Scientific Reports. 2022, 12(1), article no: 11186 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1038/s41598-022-14862-y. [277] Cortellessa, G., Stabile, L., Arpino, F., Faleiros, D. E., Bos, W. van den, Morawska, L., and Buonanno, G. Close proximity risk assessment for SARSCoV-2 infection. [Online]. Science of The Total Environment. 2021, 794, article no: 148749 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.scitotenv.2021.148749. [278] Domino, S. P. A Case Study on Pathogen Transport, Deposition, Evaporation and Transmission: Linking High-Fidelity Computational Fluid Dynamics Simulations to Probability of Infection. [Online]. International Journal of Computational Fluid Dynamics. 2021, 35(9), pp.743–757. [Accessed 1 March 2025]. Available from: https://doi.org/10.1080/10618562.2021.1905801. [279] Hedworth, H. A., Karam, M., McConnell, J., Sutherland, J. C., and Saad, T. Mitigation strategies for airborne disease transmission in orchestras using computational fluid dynamics. [Online]. Science Advances. 2021, 7(26), article no: eabg4511 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1126/sciadv.abg4511. [280] Bertone, M., Mikszewski, A., Stabile, L., Riccio, G., Cortellessa, G., d’Ambrosio, F. R., Papa, V., Morawska, L., and Buonanno, G. Assessment of SARS-CoV2 airborne infection transmission risk in public buses. [Online]. Geoscience Frontiers. 2022, 13(6), article no: 101398 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.gsf.2022.101398. [281] Rocha-Melogno, L., Crank, K., Bergin, M. H., Gray, G. C., Bibby, K., and Deshusses, M. A. Quantitative risk assessment of COVID-19 aerosol transmission indoors: a mechanistic stochastic web application. [Online]. Environmental Technology. 2023, 44(9), pp.1201–1212. [Accessed 1 March 2025]. Available from: https://doi.org/10.1080/09593330.2021.1998228. [282] Buonanno, G., Morawska, L., and Stabile, L. Quantitative assessment of the risk of airborne transmission of SARS-CoV-2 infection: Prospective and retrospective applications. [Online]. Environment International. 2020, 145, article no: 106112 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.envint.2020.106112. [283] Dhawan, S. and Biswas, P. Aerosol Dynamics Model for Estimating the Risk from Short-Range Airborne Transmission and Inhalation of Expiratory Droplets of SARS-CoV-2. [Online]. Environmental Science & Technology. 2021, 55(13), pp.8987–8999. [Accessed 1 March 2025]. Available from: https://doi.org/10.1021/acs.est.1c00235. [284] Henriques, A., Mounet, N., Aleixo, L., Elson, P., Devine, J., Azzopardi, G., Andreini, M., Rognlien, M., Tarocco, N., and Tang, J. Modelling airborne transmission of SARS-CoV-2 using CARA: risk assessment for enclosed spaces. [Online]. Interface Focus. 2022, 12(2), article no: 20210076 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1098/rsfs.2021.0076. [285] Parhizkar, H., Van Den Wymelenberg, K. G., Haas, C. N., and Corsi, R. L. A Quantitative Risk Estimation Platform for Indoor Aerosol Transmission of COVID-19. [Online]. Risk Analysis. 2022, 42(9), pp.2075–2088. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/risa.13844. [286] Carducci, A., Donzelli, G., Cioni, L., Federigi, I., Lombardi, R., and Verani, M. Quantitative Microbial Risk Assessment for Workers Exposed to Bioaerosol in Wastewater Treatment Plants Aimed at the Choice and Setup of Safety Measures. [Online]. International Journal of Environmental Research and Public Health. 2018, 15(7), article no: 1490 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.3390/ijerph15071490. [287] Carducci, A., Donzelli, G., Cioni, L., and Verani, M. Quantitative Microbial Risk Assessment in Occupational Settings Applied to the Airborne Human Adenovirus Infection. [Online]. International Journal of Environmental Research and Public Health. 2016, 13(7), article no: 733 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.3390/ijerph13070733. [288] Xu, C., Wei, X., Liu, L., Su, L., Liu, W., Wang, Y., and Nielsen, P. V. Effects of personalized ventilation interventions on airborne infection risk and transmission between occupants. [Online]. Building and Environment. 2020, 180, article no: 107008 [no pagination]. [Accessed 1 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2020.107008. [289] Nicas, M. and Jones, R. M. Relative Contributions of Four Exposure Pathways to Influenza Infection Risk. [Online]. Risk Analysis. 2009, 29(9), pp.1292–1303. [Accessed 1 March 2025]. Available from: https://doi.org/10.1111/j.1539-6924.2009.01253.x. [290] Lim, K.-Y., Hamilton, A. J., and Jiang, S. C. Assessment of public health risk associated with viral contamination in harvested urban stormwater for domestic applications. [Online]. Science of The Total Environment. 2015, 523, pp.95–108. [Accessed 5 March 2025]. Available from: https://doi.org/10.1016/j.scitotenv.2015.03.077. [291] Mousavi, E. and Bhattacharya, A. Event based approach for modeling indoor airflow patterns. [Online]. Journal of Building Engineering. 2022, 51, p.104244. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.jobe.2022.104244. [292] Ye, W., Pan, Y., He, L., Chen, B., Liu, J., Gao, J., Wang, Y., and Yang, Y. Design with modeling techniques. In: Goodfellow, H. D. and Wang, Y., eds. Industrial Ventilation Design Guidebook. [Online]. 2nd ed. Elsevier, 2021, pp.109–183. [Accessed 27 February 2025]. Available from: https://doi.org/10.1016/b978-0-12-816673-4.00008-0. [293] Noakes, C. J. and Sleigh, P. A. Mathematical models for assessing the role of airflow on the risk of airborne infection in hospital wards. [Online]. Journal of the Royal Society, Interface. 2009, 6, pp.S791–S800. [Accessed 17 March 2025]. Available from: https://doi.org/10.1098/rsif.2009.0305.focus. [294] López-García, M., King, M.-F., and Noakes, C. J. A Multicompartment SIS Stochastic Model with Zonal Ventilation for the Spread of Nosocomial Infections: Detection, Outbreak Management, and Infection Control. [Online]. Risk Analysis. 2019, 39(8), pp.1825–1842. [Accessed 3 March 2025]. Available from: https://doi.org/10.1111/risa.13300. [295] National Institute of Standards and Technology (NIST), CONTAM. [Software]. [Accessed 17 March 2025]. Available from: https://www.nist.gov/services-resources/software/contam. [296] Edwards, A. J., Benson, L., Guo, Z., López-García, M., Noakes, C. J., Peckham, D., and King, M.-F. A mathematical model for assessing transient airborne infection risks in a multi-zone hospital ward. [Online]. Building and Environment. 2023, 238, article no: 110344 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2023.110344. [297] Yan, S., Wang, L., Birnkrant, M. J., Zhai, J., and Miller, S. L. Evaluating SARS-CoV-2 airborne quanta transmission and exposure risk in a mechanically ventilated multizone office building. [Online]. Building and Environment. 2022, 219, article no: 109184 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2022.109184. [298] Shrestha, P., DeGraw, J. W., Zhang, M., and Liu, X. Multizonal modeling of SARS-CoV-2 aerosol dispersion in a virtual office building. [Online]. Building and Environment. 2021, 206, article no: 108347 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2021.108347. [299] Cheong, C. H., Park, B., and Lee, S. Design Method to Prevent Airborne Infection in an Emergency Department. [Online]. Journal of Asian Architecture and Building Engineering. 2018, 17(3), pp.573–579. [Accessed 3 March 2025]. Available from: https://doi.org/10.3130/jaabe.17.581. [300] Emmerich, S. J., Heinzerling, D., Choi, J.-i., and Persily, A. K. Multizone modeling of strategies to reduce the spread of airborne infectious agents in healthcare facilities. [Online]. Building and Environment. 2013, 60, pp.105–115. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2012.11.013. [301] Navthar, R. R., Kotakar, S. G., and Khire, M. Y., Computational Fluid Dynamics: Computer Simulation. In: 2011 3rd International Conference on Computer Technology and Development, 25 - 27 November 2011, Chengdu. [Online]. ASME Press, 2011. [Accessed 15 January 2025]. Available from: https://doi.org/10.1115/1.859919.paper190. [302] Hathway, E., Noakes, C., Sleigh, P., and Fletcher, L. CFD simulation of irborne pathogen transport due to human activities. [Online]. Building and Environment. 2011, 46(12), pp.2500–2511. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2011.06.001. [303] Wang, J. and Chow, T.-T. Influence of human movement on the transport of airborne infectious particles in hospital. [Online]. Journal of Building Performance Simulation. 2015, 8(4), pp.205–215. [Accessed 3 March 2025]. Available from: https://doi.org/10.1080/19401493.2014.905636. [304] Jo, S., Hong, J., Lee, S.-E., Ki, M., Choi, B. Y., and Sung, M. Airflow analysis of Pyeongtaek St Mary’s Hospital during hospitalization of the first Middle East respiratory syndrome patient in Korea. [Online]. Royal Society Open Science. 2019, 6(3), article no: 181164 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1098/rsos.181164. [305] Li, Y., Huang, X., Yu, I. T. S., Wong, T. W., and Qian, H. Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong. [Online]. Indoor Air. 2005, 15(2), pp.83–95. [Accessed 17 March 2025]. Available from: https://doi.org/10.1111/j.1600-0668.2004.00317.x. [306] ANSYS, Inc., ANSYS Fluent (version 2023 R2). [Software]. 2023. [Accessed 3 January 2025]. Available from: https://www.ansys.com/products. [307] Siemens Digital Industries Software, STAR CCM+. [Software]. [Accessed 17 March 2025]. Available from: https://plm.sw.siemens.com/en-US/simcenter/fluids-thermal-simulation/star-ccm/. [308] Mirzaie, M., Lakzian, E., Khan, A., Warkiani, M. E., Mahian, O., and Ahmadi, G. COVID-19 spread in a classroom equipped with partition – A CFD approach. [Online]. Journal of Hazardous Materials. 2021, 420, article no: 126587 [no pagination]. [Accessed 21 January 2025]. Available from: https://doi.org/10.1016/j.jhazmat.2021.126587. [309] Abuhegazy, M., Talaat, K., Anderoglu, O., and Poroseva, S. V. Numerical investigation of aerosol transport in a classroom with relevance to COVID-19. [Online]. Physics of Fluids. 2020, 32(10), article no: 103311 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1063/5.0029118. [310] Foster, A. and Kinzel, M. Estimating COVID-19 exposure in a classroom setting: A comparison between mathematical and numerical models. [Online]. Physics of Fluids. 2021, 33(2), article no: 021904 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1063/5.0040755. [311] Pei, G., Azimi, P., Rim, D., and Allen, J. G. A CFD study on the effect of portable air cleaner placement on airborne infection control in a classroom. [Online]. Environmental science. Processes & impacts. 2024, 26(9), pp.1476–1488. [Accessed 3 March 2025]. Available from: https://doi.org/10.1039/d4em00114a. [312] Firatoglu, Z. A. The effect of natural ventilation on airborne transmission of the COVID-19 virus spread by sneezing in the classroom. [Online]. The Science of the Total Environment. 2023, 896, article no: 165113 [no pagination]. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/j.scitotenv.2023.165113. [313] ElShimi, M., Morcos, S. M., Mostafa, G. M., Khalil, E. E., El-Hariry, G. A., and ElDegwy, A. A novel transparent cabin used in the classroom during the coronavirus pandemic: a CFD analysis. [Online]. Journal of Engineering and Applied Science. 2024, 71(1), article no: 19 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1186/s44147-023-00316-3. [314] Yan, W., Zhang, Y., Sun, Y., and Li, D. Experimental and CFD study of unsteady airborne pollutant transport within an aircraft cabin mock-up. [Online]. Building and Environment. 2009, 44(1), pp.34–43. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.buildenv.2008.01.010. [315] Webner, F., Shishkin, A., Schmeling, D., and Wagner, C. A Direct Infection Risk Model for CFD Predictions and Its Application to SARS-CoV-2 Aircraft Cabin Transmission. [Online]. Indoor Air. 2024, 2024(1), article no: 9927275 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1155/2024/9927275. [316] Zee, M., Davis, A. C., Clark, A. D., Wu, T., Jones, S. P., Waite, L. L., Cummins, J. J., and Olson, N. A. Computational fluid dynamics modeling of cough transport in an aircraft cabin. [Online]. Scientific Reports. 2021, 11(1), article no: 23329 [no pagination]. [Accessed 3 March 2025]. Available from: https://doi.org/10.1038/s41598-021-02663-8. [317] ANSYS, Inc. ANSYS Fluent Theory Guide. [Online]. 2021. [Accessed 22 January 2025]. Available from: https://www.afs.enea.it/project/neptunius/docs/fluent/html/th/main_pre.htm. [318] Ge, X., Wang, H., Liu, S., Li, Z., Tong, X., and Pu, J. Application of Fibonacci Sequence and Lucas Sequence on the Design of the Toilet Siphon Pipe Shape. [Online]. Journal of Engineering and Technological Sciences. 2019, 51(4), pp.463–478. [Accessed 18 February 2025]. Available from: https://doi.org/10.5614/j.eng.technol.sci.2019.51.4.2. [319] Li, Z., Ge, X., Li, K., and Tong, X. Siphon pipe parameter optimization of the toilet using CFD-DEM coupling method. [Online]. International Journal of Numerical Methods for Calculation and Design in Engineering. 2021, 37(1). [Accessed 18 February 2025]. Available from: https://doi.org/10.23967/j.rimni.2020.10.003. [320] Yang, S., Zhang, Y., Hemida, H., Wang, Y., and Ren, D. Flow Field Simulation Analysis of Train Siphon Toilet with Variable Pipe Diameter Based on the Investigation of Siphon Performance. [Online]. Journal of Physics: Conference Series. 2020, 1626(1), p.012099. [Accessed 18 February 2025]. Available from: https://doi.org/10.1088/1742-6596/1626/1/012099. [321] Wang, Y., Xiu, G., and Tan, H. CAD and CAE Analysis for Siphon Jet Toilet. [Online]. Physics Procedia. 2011, 19, pp.472–476. [Accessed 3 March 2025]. Available from: https://doi.org/10.1016/j.phpro.2011.06.194. [322] Wu, S.-C., Guo, M.-Y., Wang, J.-X., Yao, S., Chen, J., and Li, Y.-y. Liquid curtain-based strategy to restrain plume during flushing. [Online]. Physics of Fluids. 2020, 32(11), article no: 111707 [no pagination]. [Accessed 11 February 2025]. Available from: https://doi.org/10.1063/5.0033836. [323] Wan, J., Wei, J., Lin, Y., and Zhang, T. Numerical Investigation of Bioaerosol Transport in a Compact Lavatory. [Online]. Buildings. 2021, 11(11), article no: 526 [no pagination]. [Accessed 22 January 2025]. Available from: https://doi.org/10.3390/buildings11110526. [324] Li, P., Liu, W., and Zhang, T. T. CFD modeling of dynamic airflow and particle transmission in an aircraft lavatory. [Online]. Building Simulation. 2023, 16(8), pp.1375–1390. [Accessed 18 February 2025]. Available from: https://doi.org/10.1007/s12273-023-1031-3. [325] COMSOL, Inc., COMSOL. [Software]. 2024. [Accessed 17 March 2025]. Available from: https://www.comsol.com/. [326] Liu, H., Zhang, Z., Zhang, Y., and Zhou, X. Impact of ventilation efficiency on restraining hazardous toilet plume post-flushing in indoor environments. [Online]. Indoor and Built Environment. 2024, 33(10), pp.1897–1911. [Accessed 21 January 2025]. Available from: https://doi.org/10.1177/1420326X241262650. [327] Ho, M. S., Glass, R. I., Monroe, S. S., Madore, H. P., Stine, S., Pinsky, P. F., Cubitt, D., Ashley, C., and Caul, E. O. Viral gastroenteritis aboard a cruise ship. [Online]. Lancet (London, England). 1989, 2(8669), pp.961–965. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/s0140-6736(89)90964-1. [328] Widdowson, M.-A., Glass, R., Monroe, S., Beard, R. S., Bateman, J. W., Lurie, P., and Johnson, C. Probable Transmission of Norovirus on an Airplane. [Online]. JAMA. 2005, 293(15), pp.1855–1860. [Accessed 15 January 2025]. Available from: https://doi.org/10.1001/jama.293.15.1859. [329] National Research Council (US) Subcommittee on Microbiological Criteria. An Evaluation of the Role of Microbiological Criteria for Foods and Food Ingredients. [Online]. National Academies Press, 1985. [Accessed 24 February 2025]. Available from: https://doi.org/10.17226/372. [330] Percival, S. L., Yates, M. V., Williams, D. D., Chalmers, R., and Gray, N. Microbiology of Waterborne Diseases: Microbiological Aspects and Risks. [Online]. 2nd ed. Elsevier, 2014. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/C2010-0-67101-X. [331] Seidman, L., Kraus, M., Brandner, D., and Mowery, J. Laboratory Manual for Biotechnology and Laboratory Science. [Online]. CRC Press, 2022. [Accessed 17 March 2025]. Available from: https://doi.org/10.1201/9781003360742. [332] Noakes, C. J., Fletcher, L. A., Sleigh, P. A., Booth, W. B., Beato-Arribas, B., and Tomlinson, N., Comparison of tracer techniques for evaluating the behaviour of bioaerosols in hospital isolation rooms. In Proceedings of the Healthy Buildings, Kuala Lumpur, Malaysia, 13–17 September 2009. In: 9th International Conference and Exhibition on Healthy Buildings 2009, 13 – 17 September 2009, Syracuse. [Online]. ISIAQ, 2009, pp.1642–1645. [Accessed 17 March 2025]. Available from: https://www.proceedings.com/17570.html. [333] King, M.-F., Camargo-Valero, M., Matamoros-Veloza, A., Sleigh, P., and Noakes, C. J. An Effective Surrogate Tracer Technique for S. aureus Bioaerosols in a Mechanically Ventilated Hospital Room Replica Using Dilute Aqueous Lithium Chloride. [Online]. Atmosphere. 2017, 8(12), article no: 238 [no pagination]. [Accessed 23 May 2024]. Available from: https://doi.org/10.3390/atmos8120238. [334] Huang, H.-L., Lee, M.-K., and Shih, H.-W. Assessment of Indoor Bioaerosols n Public Spaces by Real-Time Measured Airborne Particles. [Online]. Aerosol and Air Quality Research. 2017, 17(9), pp.2276–2288. [Accessed 24 February 2025]. Available from: https://doi.org/10.4209/aaqr.2017.02.0089. [335] Božić, J., Ilić, P., and Ilić, S. Indoor Air Quality in the Hospital: The Influence of Heating, Ventilating and Conditioning Systems. [Online]. Brazilian Archives of Biology and Technology. 2019, 62, article no: p.e19180295 [no pagination]. [Accessed 24 February 2025]. Available from: https://doi.org/https://doi.org/10.1590/1678-4324-2019180295. [336] Boone, S. A., Ijaz, M. K., McKinney, J., and Gerba, C. P. Resuspension and Dissemination of MS2 Virus from Flooring After Human Activities in Built Environment: Impact of Dust Particles. [Online]. Microorganisms. 2024, 12(12), article no: 2564 [no pagination]. [Accessed 31 January 2025]. Available from: https://doi.org/10.3390/microorganisms12122564. [337] Wanger, A., Chavez, V., Huang, R. S. P., Wahed, A., Actor, J. K., and Dasgupta, A. Media for the Clinical Microbiology Laboratory. In: Wanger, A., Chavez, V., Huang, R. S. P., Wahed, A., Actor, J. K., and Dasgupta, A., eds. Microbiology and Molecular Diagnosis in Pathology. [Online]. Elsevier, 2017, pp.51–60. [Accessed 17 March 2025]. Available from: https://doi.org/10.1016/b978-0-12-805351-5.00004-1. [338] Hiwar, W., Kharrufa, H., King, M.-F., Salman, N., Fletcher, L., and Noakes, C., Multiplate air passive sampler to measure deposition rate of airborne microorganisms over time. In: 16th Conference of the International Society of Indoor Air Quality & Climate, 1 - 5 November 2020, Online. [Online]. ISIAQ, 2021, pp.708–713. [Accessed 17 March 2025]. Available from: https://www.proceedings.com/57711.html. [339] Hiwar, W., King, M.-F., Kharrufa, H., Tidswell, E., Fletcher, L. A., and Noakes, C. J. The impact of ventilation rate on reducing the microorganisms load in the air and on surfaces in a room-sized chamber. [Online]. Indoor Air. 2022, 32(11), article no: e13161 [no pagination]. [Accessed 20 February 2025]. Available from: https://doi.org/10.1111/ina.13161. [340] Hathway, A., Sleigh, A., and Noakes, C., CFD modelling of transient pathogen release in indoor environments due to human activity. In: International Conference on Room Air Distribution RoomVent 2007, 13 - 15 June 2007, Finland. [Online]. FINVAC, 2007. [Accessed 17 March 2025]. Available from: https://eprints.whiterose.ac.uk/7699/1/Hathway_Roomvent07.pdf. [341] NHS England. Health Technical Memorandum 03-01: Specialised ventilation for healthcare premises. [Online]. 2021. [Accessed 17 March 2025]. Available from: https://www.england.nhs.uk/publication/specialised-ventilationfor-healthcare-buildings/. [342] Cantium Scientific. Correction of sample counts. [Online]. [Accessed 7 March 2025]. Available from: https://confluence.external-share.com/content/685314/countcorrection. [343] The British Standards Institution. BS 6465-2:2017: Sanitary installations: Space recommendations. Code of practice. [Online]. 2017. [Accessed 17 March 2025]. Available from: https://knowledge.bsigroup.com/products/sanitaryinstallations-space-recommendations-code-of-practice. [344] R Foundation for Statistical Computing, R: A Language and Environment for Statistical Computing. [Software]. 2023. [Accessed 17 March 2025]. Available from: https://www.R-project.org/. [345] Schmid-Hempel, P. and Frank, S. A. Pathogenesis, Virulence, and Infective Dose. [Online]. PLoS Pathogens. 2007, 3(10), article no: e147 [no pagination]. [Accessed 23 February 2025]. Available from: https://doi.org/10.1371/journal.ppat.0030147. [346] Ramlal, P. S., Lin, J., Buckley, C. A., Stenström, T. A., and Amoah, I. D. An assessment of the health risks associated with shared sanitation: a case study of the community ablution blocks in Durban, South Africa. [Online]. Environmental Monitoring and Assessment. 2022, 194(3), article no: 166 [no pagination]. [Accessed 23 February 2025]. Available from: https://doi.org/10.1007/s10661-022-09815-x. [347] Higham, C. A., López-García, M., Noakes, C. J., Tidswell, E., and Fletcher, L. A Quantitative Microbial Risk Assessment (QMRA) framework for exposure from toilet flushing using experimental aerosol concentration measurements. [Online]. Indoor Environments. 2025, 2(1), article no: 100069 [no pagination]. [Accessed 10 March 2025]. Available from: https://doi.org/10.1016/j.indenv.2024.100069. [348] Rawls, S. K. Restroom usage in selected public buildings and facilities: a comparison of females and males. Ph.D thesis. Virginia Polytechnic Institute and State University, 1988. [349] Gwynne, S. M. V., Hunt, A. L. E., Thomas, J. R., Thompson, A. J. L., and Séguin, L. The toilet paper: Bathroom dwell time observations at an airport. [Online]. Journal of Building Engineering. 2019, 24, article no: 100751 [no pagination]. [Accessed 21 May 2024]. Available from: https://doi.org/10.1016/j.jobe.2019.100751. [350] Baillie, M. A., Fraser, S., and Brown, M. J. Do women spend more time in the restroom than men? [Online]. Psychological Reports. 2009, 105(3), pp.789–790. [Accessed 8 September 2024]. Available from: https://doi.org/10.2466/PR0.105.3.789-790."],"dcterms:accessrights":["public"],"dc:title":["Characterising the Emission and Dispersion of Aerosols from the Toilet Plume and Quantification of the Associated Infection Risk"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Integrated Ph.D and Master"],"person:identifier.orcid":["0000000312138149"]},"updated_at":"2026-11-18T23:29:36Z"}