{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:37163"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:37163","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Quantifying knee meniscus tissue behaviour: A combined experimental and computational study","abstract":"Damage to knee meniscus tissue has been associated with the onset and progression of musculoskeletal diseases such as osteoarthritis. Through previous computational studies, the meniscus material property parameters have been found to directly affect knee contact mechanics and meniscus kinematics considered as key variables that reflect knee and meniscus health. However, characterising these properties remain challenging. Previous studies have used techniques that compromise tissue integrity, require sectioning of meniscus tissue or make compromising assumptions leading to potential inaccuracies in measurements. The aim of the study was to develop new methods to characterise meniscus mechanical properties. This involved imaging the tissue under load and using inverse finite element analysis with corresponding meniscus kinematic measurements from MRI data. A sensitivity analysis was conducted to establish meniscus radial distance sensitivity to linear transverse isotropic material property parameters. An added feature that distinguishes the current study was the study of both meniscus kinematics and contact mechanics concurrently with changes to meniscus property parameters to understand their relationship. The outcomes suggest a 3T MRI scanner of isotropic resolution ~0.3 mm would sufficiently capture meniscus kinematics and that the Efibre, Eplane and Gplane-fibre material parameters would be sufficient for capturing meniscus response in situ. Meniscus kinematics and contact mechanics were found to be linked in their response. A novel MRI-compatible loading rig was designed, built and calibrated for loading the knee joint in vitro following the finite element sensitivity analysis. The MRI-compatible rig provides for two flexion configurations (i.e., neutral and 45 degrees in flexion) and allows axial rotation, a key component relevant to the screw-home mechanism, to investigate its effect on meniscus loading and response. Meniscus radial distance measurements were obtained for various loading and knee configurations from the MR images for three porcine samples. A novel feature was that the measurements were made with reference to tibial tubercles locations such that the tibia internal-external rotations could be assumed to have no effect on the measures. Knee FE models were built, and the meniscus radial distance measurement technique replicated programmatically for material property identification purposes using the finite element method updating procedure with the particle swarm optimiser. Outcomes from the material property parameter identification study suggested consistency in the Eplane term at 20 MPa for all the three porcine samples considered. The derived Efibre term was in the range 161 MPa to 250 MPa while the Gplane-fibre term occurred in the range 13 MPa to 30 MPa. Normalised root mean squared error (NRMSE) in the range 7% to 11% was measured for the three knee samples used. Outcomes were verified using a brute force parameter identification technique. A validation study performed using meniscus radial distances obtained from a different knee configuration was deemed inconclusive due to modelling difficulties. However, a partial validation based on the medial meniscus radial distances showed NRMSE of ~9 % which was comparable to the optimised ranges. Porcine lateral meniscus kinematics were not sufficiently captured using the developed knee FE model. To conclude novel methods were developed for the non-invasive characterisation of subject-specific meniscus material property parameters using a combination of measurements from medical imaging and computational techniques. The methods developed provides for the characterisation of representative human meniscal tissue material properties and the assessment of meniscus replacement devices laying the foundations for patient stratification studies.","abstract_html":"Damage to knee meniscus tissue has been associated with the onset and progression of musculoskeletal diseases such as osteoarthritis. Through previous computational studies, the meniscus material property parameters have been found to directly affect knee contact mechanics and meniscus kinematics considered as key variables that reflect knee and meniscus health. However, characterising these properties remain challenging. Previous studies have used techniques that compromise tissue integrity, require sectioning of meniscus tissue or make compromising assumptions leading to potential inaccuracies in measurements. The aim of the study was to develop new methods to characterise meniscus mechanical properties. This involved imaging the tissue under load and using inverse finite element analysis with corresponding meniscus kinematic measurements from MRI data. A sensitivity analysis was conducted to establish meniscus radial distance sensitivity to linear transverse isotropic material property parameters. An added feature that distinguishes the current study was the study of both meniscus kinematics and contact mechanics concurrently with changes to meniscus property parameters to understand their relationship. The outcomes suggest a 3T MRI scanner of isotropic resolution ~0.3 mm would sufficiently capture meniscus kinematics and that the Efibre, Eplane and Gplane-fibre material parameters would be sufficient for capturing meniscus response in situ. Meniscus kinematics and contact mechanics were found to be linked in their response. A novel MRI-compatible loading rig was designed, built and calibrated for loading the knee joint in vitro following the finite element sensitivity analysis. The MRI-compatible rig provides for two flexion configurations (i.e., neutral and 45 degrees in flexion) and allows axial rotation, a key component relevant to the screw-home mechanism, to investigate its effect on meniscus loading and response. Meniscus radial distance measurements were obtained for various loading and knee configurations from the MR images for three porcine samples. A novel feature was that the measurements were made with reference to tibial tubercles locations such that the tibia internal-external rotations could be assumed to have no effect on the measures. Knee FE models were built, and the meniscus radial distance measurement technique replicated programmatically for material property identification purposes using the finite element method updating procedure with the particle swarm optimiser. Outcomes from the material property parameter identification study suggested consistency in the Eplane term at 20 MPa for all the three porcine samples considered. The derived Efibre term was in the range 161 MPa to 250 MPa while the Gplane-fibre term occurred in the range 13 MPa to 30 MPa. Normalised root mean squared error (NRMSE) in the range 7% to 11% was measured for the three knee samples used. Outcomes were verified using a brute force parameter identification technique. A validation study performed using meniscus radial distances obtained from a different knee configuration was deemed inconclusive due to modelling difficulties. However, a partial validation based on the medial meniscus radial distances showed NRMSE of ~9 % which was comparable to the optimised ranges. Porcine lateral meniscus kinematics were not sufficiently captured using the developed knee FE model. To conclude novel methods were developed for the non-invasive characterisation of subject-specific meniscus material property parameters using a combination of measurements from medical imaging and computational techniques. The methods developed provides for the characterisation of representative human meniscal tissue material properties and the assessment of meniscus replacement devices laying the foundations for patient stratification studies.","abstract_has_math":false,"creators":["Zantiba, Sherif Abubakari"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Wilcox, Ruth","Mengoni, Marlène","Wijayathunga, Nagitha","Conaghan, Philip"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-11","date_published":"2024-11","updated_at":"2026-11-18T23:30:26Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["2444470"],"render_values":[{"text":"2444470","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000232232813"],"render_values":[{"text":"0000-0002-3223-2813","href":"https://orcid.org/0000-0002-3223-2813","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/37163/1/SZ_Thesis_2024%20-%20Quantifying%20knee%20meniscus%20tissue%20behaviour.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A37163","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wilcox, Ruth","Mengoni, Marlène","Wijayathunga, Nagitha","Conaghan, Philip"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["EPSRC"]},{"key":"dc:creator","label":"Author","values":["Zantiba, Sherif Abubakari"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000232232813"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-11"]},{"key":"dc:date.issued","label":"Date","values":["2024-11"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Mechanical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/37163/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] NHS England » Musculoskeletal health. [Online]. Available: https://www.england.nhs.uk/elective-care-transformation/best-practice-solutions/musculoskeletal/. [Accessed: 14 Oct. 2024]. [2] E. Biver et al., ‘Gut microbiota and osteoarthritis management: An expert consensus of the European society for clinical and economic aspects of osteoporosis, osteoarthritis and musculoskeletal diseases (ESCEO)’, Ageing Research Reviews, vol. 55, p. 100946, Nov. 2019 [Online]. Available: 10.1016/j.arr.2019.100946. [3] S. Jerban et al., ‘Magnetic resonance imaging (MRI) studies of knee joint under mechanical loading: Review’, Magnetic Resonance Imaging, vol. 65, no. August 2019, pp. 27–36, 2020 [Online]. Available: 10.1016/j.mri.2019.09.007. [4] V. L. Johnson and D. J. Hunter, ‘The epidemiology of osteoarthritis’, Best Practice and Research: Clinical Rheumatology, vol. 28, no. 1, pp. 5–15, Feb. 2014 [Online]. Available: 10.1016/j.berh.2014.01.004. [5] K. M. Fischenich et al., ‘Chronic changes in the articular cartilage and meniscus following traumatic impact to the lapine knee’, J Biomech, vol. 48, no. 2, pp. 246–253, Jan. 2015 [Online]. Available: 10.1016/j.jbiomech.2014.11.038. [6] S. Fathy and M. El Messiry, ‘Study of the Effect of Cyclic Stress on the Mechanical Properties of Braided Anterior Cruciate Ligament (ACL)’, Journal of Textile Science & Engineering, vol. 06, no. 02, 2016 [Online]. Available: 10.4172/2165-8064.1000252 [Accessed: 22 January 2021]. [7] Z. Trad et al., ‘Finite element models of the knee joint’, in SpringerBriefs in Applied Sciences and Technology, no. 9783319741574, Springer Verlag, 2018, pp. 1–34 [Online]. Available: 10.1007/978-3-319-74158-1_1 [Accessed: 18 November 2020]. [8] L. S. Lohmander et al., ‘The long-term consequence of anterior cruciate ligament and meniscus injuries: Osteoarthritis’, American Journal of Sports Medicine, vol. 35, no. 10, pp. 1756–1769, Oct. 2007 [Online]. Available: 10.1177/0363546507307396. [9] A. J. S. Fox et al., ‘The Basic Science of Human Knee Menisci: Structure, Composition, and Function’, Sports Health, vol. 4, no. 4, pp. 340–351, Jul. 2012 [Online]. Available: 10.1177/1941738111429419. [10] A. J. S. Fox et al., ‘The human meniscus: A review of anatomy, function, injury, and advances in treatment’, Clinical Anatomy, vol. 28, no. 2, pp. 269–287, 2015 [Online]. Available: 10.1002/ca.22456. [11] C. Scotti et al., ‘Meniscus repair and regeneration: review on current methods and research potential’, European Cells and Materials, vol. 26, pp. 150–170, Sep. 2013 [Online]. Available: 10.22203/eCM.v026a11. [12] L. R. Shelton, ‘A closer look at osteoarthritis’, Nurse Practitioner, vol. 38, no. 7, pp. 30–36, Jul. 2013 [Online]. Available: 10.1097/01.NPR.0000431178.49311.42. [13] M. Englund et al., ‘The Role of the Meniscus in Knee Osteoar thritis : a Cause or Consequence?’ [Online]. Available: 10.1016/j.rcl.2009.03.003 [Accessed: 28 July 2021]. [14] T. J. Fairbank, ‘Knee joint changes after meniscectomy.’, The Journal of bone and joint surgery. American volume, vol. 30 B, no. 4, pp. 664–670, 1948 [Online]. Available: 10.1302/0301-620x.30b4.664. [15] A. M. Seitz et al., ‘Osteoarthritis-Related Degeneration Alters the Biomechanical Properties of Human Menisci Before the Articular Cartilage’, Frontiers in Bioengineering and Biotechnology, vol. 9, May 2021 [Online]. Available: 10.3389/FBIOE.2021.659989 [Accessed: 28 July 2021]. [16] C. A. Murphy et al., ‘The Meniscus in Normal and Osteoarthritic Tissues: Facing the Structure Property Challenges and Current Treatment Trends’, Annual Review of Biomedical Engineering, vol. 21, no. 1, pp. 495–521, Jun. 2019 [Online]. Available: 10.1146/annurev-bioeng-060418. [17] K. Messner and J. Gao, ‘The menisci of the knee joint. Anatomical and functional characteristics, and a rationale for clinical treatment’, Journal of Anatomy, vol. 193, no. 2, pp. 161–178, Aug. 1998 [Online]. Available: 10.1046/j.1469-7580.1998.19320161.x. [18] I. D. Hutchinson et al., ‘Restoration of the meniscus: Form and function’, American Journal of Sports Medicine, vol. 42, no. 4, pp. 987–998, Apr. 2014 [Online]. Available: 10.1177/0363546513498503. [19] A. C. T. Vrancken et al., ‘3D geometry analysis of the medial meniscus - A statistical shape modeling approach’, Journal of Anatomy, vol. 225, no. 4, pp. 395–402, 2014 [Online]. Available: 10.1111/joa.12223. [20] J. J. Elsner et al., ‘Mri-based characterization of bone anatomy in the human knee for size matching of a medial meniscal implant’, Journal of Biomechanical Engineering, vol. 132, no. 10, pp. 1–11, 2010 [Online]. Available: 10.1115/1.4002490. [21] P. Łuczkiewicz et al., ‘Influence of meniscus shape in the cross sectional plane on the knee contact mechanics’, Journal of Biomechanics, vol. 48, no. 8, pp. 1356–1363, Jun. 2015 [Online]. Available: 10.1016/J.JBIOMECH.2015.03.002. [22] J. R. Meakin et al., ‘Finite element analysis of the meniscus: The influence of geometry and material properties on its behaviour’, Knee, vol. 10, no. 1, pp. 33–41, Mar. 2003 [Online]. Available: 10.1016/S0968-0160(02)00106-0. [23] Q. Meng et al., ‘The effects of geometric uncertainties on computational modelling of knee biomechanics’, Royal Society Open Science, vol. 4, no. 8, p. 170670, Aug. 2017 [Online]. Available: 10.1098/rsos.170670. [24] J. Yao et al., ‘Effect of meniscus modelling assumptions in a static tibiofemoral finite element model: importance of geometry over material’, Biomech Model Mechanobiol, vol. 23, no. 3, pp. 1055–1065, Jun. 2024 [Online]. Available: 10.1007/s10237-024-01822-w. [25] K. N. Hauch et al., ‘Geometry, time-dependent and failure properties of human meniscal attachments’[Online]. Availablewww.elsevier.com/locate/jbiomech[Accessed: 9June2023]. [26] D. Kohn and B. Moreno, ‘Meniscus insertion anatomy as a basis for meniscus replacement: A morphological cadaveric study’, Arthroscopy: The Journal of Arthroscopic and Related Surgery, vol. 11, no. 1, pp. 96–103, Feb. 1995 [Online]. Available: 10.1016/0749-8063(95)90095-0. [27] E. K. Danso et al., ‘Characterization of site-specific biomechanical properties of human meniscus-Importance of collagen and fluid on mechanical nonlinearities’, Journal of Biomechanics, vol. 48, no. 8, pp. 1499–1507, Jun. 2015 [Online]. Available: 10.1016/j.jbiomech.2015.01.048. [28] E. K. Danso et al., ‘Comparison of nonlinear mechanical properties of bovine articular cartilage and meniscus’, Journal of Biomechanics, vol. 47, no. 1, pp. 200–206, Jan. 2014 [Online]. Available: 10.1016/j.jbiomech.2013.09.015. [29] K. Lechner et al., ‘Is the circumferential tensile modulus within a human medial meniscus affected by the test sample location and cross-sectional area?’, Journal of Orthopaedic Research, vol. 18, no. 6, pp. 945–951, Jan. 2000 [Online]. Available: 10.1002/JOR.1100180614. [30] D. C. Fithian et al., ‘Material Properties and Structure-Function Relationships in the Menisci’, Clinical Orthopaedics and Related Research®, vol. 252, p. 19, Mar. 1990. [31] C. S. Proctor et al., ‘Material properties of the normal medial bovine meniscus’, Journal of Orthopaedic Research, vol. 7, no. 6, pp. 771–782, 1989 [Online]. Available: 10.1002/jor.1100070602. [32] J. M. Peloquin et al., ‘Advances in quantification of meniscus tensile mechanics including nonlinearity, yield, and failure’, Journal of Biomechanical Engineering, vol. 138, no. 2, Feb. 2016 [Online]. Available: 10.1115/1.4032354 [Accessed: 12 March 2023]. [33] M. Tissakht and A. M. Ahmed, ‘Tensile stress-strain characteristics of the human meniscal material’, Journal of Biomechanics, vol. 28, no. 4, pp. 411–422, 1995 [Online]. Available: 10.1016/0021-9290(94)00081-E. [34] M. L. Tanaka et al., ‘Comparison of Biomechanical Properties of Native Menisci and Bacterial Cellulose Implant’, International Journal of Polymeric Materials and Polymeric Biomaterials, vol. 63, no. 17, pp. 891–897, Nov. 2014 [Online]. Available: 10.1080/00914037.2014.886226. [35] T. L. Haut Donahue et al., ‘How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint’, Journal of Biomechanics, vol. 36, no. 1, pp. 19–34, Jan. 2003 [Online]. Available: 10.1016/S0021-9290(02)00305-6. [36] J. Yao et al., ‘Sensitivities of Medial Meniscal Motion and Deformation to Material Properties of Articular Cartilage, Meniscus and Meniscal Attachments Using Design of Experiments Methods’, Journal of Biomechanical Engineering, vol. 128, no. 3, pp. 399–408, Dec. 2005 [Online]. Available: 10.1115/1.2191077. [37] M. Mengoni, ‘Using inverse finite element analysis to identify spinal tissue behaviour in situ’, Methods, vol. 185, pp. 105–109, Jan. 2020 [Online]. Available: 10.1016/j.ymeth.2020.02.004. [38] T. Simkheada et al., ‘Comparison of constitutive models for meniscus and their effect on the knee joint biomechanics during gait’, Computer Methods in Biomechanics and Biomedical Engineering, vol. 0, no. 0, pp. 1–14, 2022 [Online]. Available: 10.1080/10255842.2022.2163587. [39] B. B. Wheatley et al., ‘An optimized transversely isotropic, hyper-poro-viscoelastic finite element model of the meniscus to evaluate mechanical degradation following traumatic loading’, Journal of Biomechanics, vol. 48, no. 8, pp. 1454–1460, Jun. 2015 [Online]. Available: 10.1016/J.JBIOMECH.2015.02.028. [40] B. Seyfi et al., ‘Mechanical modeling and characterization of meniscus tissue using flat punch indentation and inverse finite element method’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 77, pp. 337–346, Jan. 2018 [Online]. Available: 10.1016/J.JMBBM.2017.09.023. [41] M. A. Sweigart et al., ‘Intraspecies and Interspecies Comparison of the Compressive Properties of the Medial Meniscus’, Annals of Biomedical Engineering, vol. 32, no. 11, pp. 1569–1579, Nov. 2004 [Online]. Available: 10.1114/B:ABME.0000049040.70767.5c. [42] M. De Rosa et al., ‘Mechanical properties of meniscal circumferential fibers using an inverse finite element analysis approach’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 126, p. 105073, Feb. 2022 [Online]. Available: 10.1016/j.jmbbm.2022.105073. [43] M. Freutel et al., ‘Material properties of individual menisci and their attachments obtained through inverse FE-analysis’[Online]. Availablehttp://dx.doi.org/10.1016/j.jbiomech.2015.03.014. [44] E. Peña et al., ‘Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics’, Clinical Biomechanics, vol. 20, no. 5, pp. 498–507, 2005 [Online]. Available: 10.1016/j.clinbiomech.2005.01.009. [45] B. B. Avants et al., ‘A reproducible evaluation of ANTs similarity metric performance in brain image registration’, NeuroImage, vol. 54, no. 3, pp. 2033–2044, Feb. 2011 [Online]. Available: 10.1016/j.neuroimage.2010.09.025. [46] R. J. Cooper et al., ‘Three subject-specific human tibiofemoral joint finite element models: complete three-dimensional imaging (CT & MR), experimental validation and modelling dataset.’, [Dataset], 2023[Online]. Availablehttps://archive.researchdata.leeds.ac.uk/1082/[Accessed: 19June2023]. [47] R. Readiof et al., ‘Replicating the mechanical environment of an experimental natural knee simulator in specimen-specific tibiofemoral finite element models for the study of menisci.’, in 17th International Symposium on Computational Methods in Biomechanics and Biomedical Engineering and 5th Conference on Imaging and Visualisation., Germany, 2021. [48] V. Sanchis-Alfonso et al., ‘Evaluation of Patellar Contact Pressure Changes after Static versus Dynamic Medial Patellofemoral Ligament Reconstructions Using a Finite Element Model’, Journal of Clinical Medicine, vol. 8, no. 12, p. 2093, Dec. 2019 [Online]. Available: 10.3390/jcm8122093. [49] K. A. Athanasiou and J. Sanchez-Adams, ‘Synthesis Lectures on Tissue Engineering Engineering the Knee Meniscus’, 2009[Online]. Availablewww.morganclaypool.com[Accessed: 10August2020]. [50] E. S. Grood et al., ‘Ligamentous Medial and Capsular Laxity Restraints in Intact’, The Journal of Bone and Joint Surgery, vol. 63, no. 8, pp. 1257–1269, 1981. [51] S. D. Masouros et al., ‘(i) Biomechanics of the knee joint’, Orthopaedics and Trauma, vol. 24, no. 2, pp. 84–91, Apr. 2010 [Online]. Available: 10.1016/j.mporth.2010.03.005. [52] C. M. Gupte et al., ‘The meniscofemoral ligaments: Secondary restraints to the posterior drawer’, Journal of Bone and Joint Surgery - Series B, vol. 85, no. 5, pp. 765–773, Jul. 2003 [Online]. Available: 10.1302/0301-620x.85b5.13771. [53] S. Knecht et al., ‘A review on the mechanical quality of articular cartilage - Implications for the diagnosis of osteoarthritis’, Clinical Biomechanics, vol. 21, no. 10, pp. 999–1012, Dec. 2006 [Online]. Available: 10.1016/j.clinbiomech.2006.07.001. [54] J. R. Ralphs and M. Benjamin, ‘The joint capsule: structure, composition, ageing and disease*’, 1994. [55] N. Caplan and D. F. Kader, ‘Ligamentous restraints to anterior-posterior drawer in the human knee: A biomechanical study’, in Classic Papers in Orthopaedics, 2014, pp. 141–143[Online]. Availablewww.ejbjs.org[Accessed: 14December2020]. [56] K. Tanifuji et al., ‘Three-dimensional computed tomography confirmed that the meniscal root attachments and meniscofemoral ligaments are morphologically consistent’, Knee Surgery, Sports Traumatology, Arthroscopy, vol. 28, pp. 3450–3456, 2020 [Online]. Available: 10.1007/s00167-020-06095-1. [57] P. S. Walker and J. V. Hajek, ‘The load-bearing area in the knee joint’, Journal of Biomechanics, vol. 5, no. 6, pp. 581–589, Nov. 1972 [Online]. Available: 10.1016/0021-9290(72)90030-9. [58] W. I. Hammer, Functional Soft Tissue Examination and Treatment by Manual Methods: New Perspectives. Jones and Bartlett Publishers, 2005[Online]. Availablehttps://books.google.co.uk/books?id=4b5Dy_clARAC. [59] D. J. Hunter and S. Bierma-Zeinstra, ‘Osteoarthritis’, The Lancet, vol. 393, no. 10182, pp. 1745–1759, Apr. 2019 [Online]. Available: 10.1016/S0140-6736(19)30417-9. [60] E. Rath and J. C. Richmond, ‘The menisci: basic science and advances in treatment’[Online]. Availablehttp://bjsm.bmj.com/[Accessed: 3December2020]. [61] P. S. Walker and M. J. Erkman, ‘The role of the menisci in force transmission across the knee’, CLIN.ORTHOP., vol. No. 109, pp. 184–192, 1975 [Online]. Available: 10.1097/00003086-197506000-00027. [62] B. B. Seedhom and D. J. Hargreaves, ‘Transmission of the load in the knee joint with special reference to the role of the menisci PART II: experimental results, discussion and conclusions Experimental work Specimens and test conditions’, 1979. [63] E. A. Makris et al., ‘The knee meniscus: Structure-function, pathophysiology, current repair techniques, and prospects for regeneration’, Biomaterials, vol. 32, no. 30, pp. 7411–7431, Oct. 2011 [Online]. Available: 10.1016/j.biomaterials.2011.06.037. [64] I. D. McDermott et al., ‘An anatomical study of meniscal allograft sizing’, Knee Surgery, Sports Traumatology, Arthroscopy, vol. 12, no. 2, pp. 130–135, Mar. 2004 [Online]. Available: 10.1007/s00167-003-0366-7. [65] T. Takroni et al., ‘Anatomical study: comparing the human, sheep and pig knee meniscus’, Journal of Experimental Orthopaedics, vol. 3, no. 1, 2016[Online]. Availablehttp://dx.doi.org/10.1186/s40634-016-0071-3. [66] B. L. Proffen et al., ‘A comparative anatomical study of the human knee and six animal species’, Knee, vol. 19, no. 4, pp. 493–499, Aug. 2012 [Online]. Available: 10.1016/j.knee.2011.07.005. [67] E. S. Mameri et al., ‘Review of Meniscus Anatomy and Biomechanics’, Current Reviews in Musculoskeletal Medicine, vol. 15, no. 5, p. 323, Aug. 2022 [Online]. Available: 10.1007/s12178-022-09768-1. [68] D. L. Johnson et al., ‘Insertion-site anatomy of the human menisci: Gross, arthroscopic, and topographical anatomy as a basis for meniscal transplantation’, Arthroscopy: The Journal of Arthroscopic and Related Surgery, vol. 11, no. 4, pp. 386–394, Aug. 1995 [Online]. Available: 10.1016/0749-8063(95)90188-4. [69] D. C. Fithian et al., ‘Material properties and structure-function relationships in the menisci’, Clin Orthop Relat Res, no. 252, pp. 19–31, Mar. 1990. [70] M. A. Sweigart and K. A. Athanasiou, ‘Toward tissue engineering of the knee meniscus’, in Tissue Engineering, 2001, vol. 7, no. 2, pp. 111–129[Online]. Availablehttps://www.liebertpub.com/doi/abs/10.1089/107632701300062697[Accessed: 3December2020]. [71] D. L. Skaggs et al., ‘Radial tie fibers influence the tensile properties of the bovine medial meniscus’, Journal of Orthopaedic Research, vol. 12, no. 2, pp. 176–185, Mar. 1994 [Online]. Available: 10.1002/jor.1100120205. [72] C. M. Gupte et al., ‘Meniscofemoral ligaments revisited’, The Journal of Bone and Joint Surgery. British volume, vol. 84-B, no. 6, pp. 846–851, Aug. 2002 [Online]. Available: 10.1302/0301-620x.84b6.0840846. [73] J. Herwig et al., ‘Chemical changes of human knee joint menisci in various stages of degeneration’, Annals of the Rheumatic Diseases, vol. 43, no. 4, pp. 635–640, Aug. 1984 [Online]. Available: 10.1136/ard.43.4.635. [74] M. Imeni et al., ‘Constitutive modeling of menisci tissue: a critical review of analytical and numerical approaches’, Biomechanics and Modeling in Mechanobiology, vol. 19, no. 6, pp. 1979–1996, Dec. 2020 [Online]. Available: 10.1007/s10237-020-01352-1. [75] N. G. Shrive et al., ‘Load-bearing in the knee joint’, Clinical Orthopaedics and Related Research, vol. NO.131, no. 131, pp. 279–287, Mar. 1978 [Online]. Available: 10.1097/00003086-197803000-00046. [76] J. Melrose et al., ‘The biology of meniscal pathology in osteoarthritis and its contribution to joint disease: beyond simple mechanics’, CONNECTIVE TISSUE RESEARCH, vol. 58, no. 3–4, SI, pp. 282–294, 2017 [Online]. Available: 10.1080/03008207.2017.1284824. [77] M. Benjamin et al., ‘Quantitative differences in the histology of the attachment zones of the meniscal horns in the knee joint of man.’, Journal of anatomy, vol. 177, pp. 127–34, Aug. 1991. [78] T. J. A. Mommersteeg et al., ‘Nonuniform distribution of collagen density in human knee ligaments’, Journal of Orthopaedic Research, vol. 12, no. 2, pp. 238–245, Mar. 1994 [Online]. Available: 10.1002/jor.1100120213. [79] C. M. Disney et al., ‘A review of techniques for visualising soft tissue microstructure deformation and quantifying strain Ex Vivo’, Journal of Microscopy, vol. 272, no. 3, pp. 165–179, Dec. 2018 [Online]. Available: 10.1111/jmi.12701. [80] J. Schwer et al., The biomechanical properties of human menisci: A systematic review - ScienceDirect. [Online]. Available: https://www.sciencedirect.com/science/article/pii/S1742706123007146?fr=RR-2&ref=pdf_download&rr=88c7cb130d7c2213. [Accessed: 31 May 2024]. [81] M. Kazemi et al., ‘Recent advances in computational mechanics of the human knee joint’, Computational and Mathematical Methods in Medicine, vol. 2013, p. 28, 2013 [Online]. Available: 10.1155/2013/718423. [82] E. Donnelly, ‘Methods for assessing bone quality: A review’, in Clinical Orthopaedics and Related Research, 2011, vol. 469, no. 8, pp. 2128–2138[Online]. Availablehttps://www.ncbi.nlm.nih.gov/pubmed/21116752[Accessed: 5December2019]. [83] S. E. Arevalo et al., ‘A methodological framework for nanomechanical characterization of soft biomaterials and polymers’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 134, p. 105384, Oct. 2022 [Online]. Available: 10.1016/j.jmbbm.2022.105384. [84] T. C. Gasser et al., ‘Hyperelastic modelling of arterial layers with distributed collagen fibre orientations’, Journal of the Royal Society Interface, vol. 3, no. 6, pp. 15–35, 2006 [Online]. Available: 10.1098/rsif.2005.0073. [85] G. A. Holzapfel et al., ‘A new constitutive framework for arterial wall mechanics and a comparative study of material models’, Journal of Elasticity, vol. 61, no. 1–3, pp. 1–48, 2000 [Online]. Available: 10.1023/A:1010835316564. [86] M. Mengoni et al., ‘Annulus fibrosus functional extrafibrillar and fibrous mechanical behaviour: Experimental and computational characterisation’, Royal Society Open Science, vol. 4, no. 8, Aug. 2017 [Online]. Available: 10.1098/rsos.170807 [Accessed: 9 October 2020]. [87] K. Navindaran et al., ‘Techniques for characterizing mechanical properties of soft tissues’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 138, p. 105575, Feb. 2023 [Online]. Available: 10.1016/j.jmbbm.2022.105575. [88] P. B. Lewis et al., ‘Multiple freeze-thaw cycled meniscal allograft tissue: A biomechanical, biochemical, and histologic analysis’, J Orthop Res, vol. 26, no. 1, pp. 49–55, Jan. 2008 [Online]. Available: 10.1002/jor.20473. [89] S. Ahmad et al., ‘Cryopreservation versus fresh frozen meniscal allograft: A biomechanical comparative analysis’, J Orthop Surg (Hong Kong), vol. 25, no. 3, p. 2309499017727946, Sep. 2017 [Online]. Available: 10.1177/2309499017727946. [90] A. C. Abraham et al., ‘Hyperelastic properties of human meniscal attachments’, Journal of Biomechanics, vol. 44, no. 3, pp. 413–418, Feb. 2011 [Online]. Available: 10.1016/j.jbiomech.2010.10.001. [91] P. G. Bullough et al., ‘The strength of the menisci of the knee as it relates to their fine structure’, J Bone Joint Surg Br, vol. 52, no. 3, pp. 564–567, Aug. 1970. [92] D. Q. Nesbitt et al., ‘Effect of age on the failure properties of human meniscus: high-speed strain mapping of tissue tears’, Journal of Biomechanics, p. 110126, 2020 [Online]. Available: 10.1016/j.jbiomech.2020.110126. [93] D. Warnecke et al., ‘Degeneration alters the biomechanical properties and structural composition of lateral human menisci’, Osteoarthritis Cartilage, vol. 28, no. 11, pp. 1482–1491, Nov. 2020 [Online]. Available: 10.1016/j.joca.2020.07.004. [94] M. Freutel et al., ‘Mechanical properties and morphological analysis of the transitional zone between meniscal body and ligamentous meniscal attachments’, Journal of Biomechanics, vol. 48, no. 8, pp. 1350–1355, Jun. 2015 [Online]. Available: 10.1016/j.jbiomech.2015.03.003. [95] B. S. Henderson et al., ‘Tensile fatigue strength and endurance limit of human meniscus’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 127, p. 105057, Mar. 2022 [Online]. Available: 10.1016/j.jmbbm.2021.105057. [96] K. M. Fischenich et al., ‘Effects of degeneration on the compressive and tensile properties of human meniscus’, J Biomech, vol. 48, no. 8, pp. 1407–1411, Jun. 2015 [Online]. Available: 10.1016/j.jbiomech.2015.02.042. [97] X. Y. Yin et al., ‘The Perimensical Capsule: Potential Supporting Structure Surrounding Meniscus’, CARTILAGE, vol. 13, no. 1_suppl, pp. 208S-215S, Dec. 2021 [Online]. Available: 10.1177/1947603519892316. [98] J. M. Párraga Quiroga et al., ‘Should a native depth-dependent distribution of human meniscus constitutive components be considered in FEA-models of the knee joint?’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 38, pp. 242–250, Oct. 2014 [Online]. Available: 10.1016/j.jmbbm.2014.03.005. [99] C. Jacquet et al., ‘Preservation Methods Influence the Biomechanical Properties of Human Lateral Menisci: An Ex Vivo Comparative Study of 3 Methods’, Orthopaedic Journal of Sports Medicine, vol. 7, no. 4, p. 2325967119841622, Apr. 2019 [Online]. Available: 10.1177/2325967119841622. [100] S. Yan et al., ‘Tensile biomechanical characteristics of human meniscus’, Emerging Materials Research, vol. 5, pp. 1–6, Jun. 2016 [Online]. Available: 10.1680/jemmr.15.00031. [101] J. D. Finan et al., ‘Non-ideal effects in indentation testing of soft tissues’, Biomech Model Mechanobiol, vol. 13, no. 3, pp. 573–584, Jun. 2014 [Online]. Available: 10.1007/s10237-013-0519-7. [102] A. E. Peters et al., ‘Tissue material properties and computational modelling of the human tibiofemoral joint: A critical review’, PeerJ, vol. 2018, no. 1, 2018[Online]. Availablehttps://pubmed.ncbi.nlm.nih.gov/29379690/[Accessed: 26November2020]. [103] A. M. Seitz et al., ‘Stress-relaxation response of human menisci under confined compression conditions’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 26, pp. 68–80, Oct. 2013 [Online]. Available: 10.1016/j.jmbbm.2013.05.027. [104] T. Long et al., ‘Experiments and hyperelastic modeling of porcine meniscus show heterogeneity at high strains’, Biomech Model Mechanobiol, vol. 21, no. 6, pp. 1641–1658, Dec. 2022 [Online]. Available: 10.1007/s10237-022-01611-3. [105] K. N. Hauch et al., ‘Nanoindentation of the insertional zones of human meniscal attachments into underlying bone’, 2008[Online]. Availablewww.sciencedirect.comjournalhomepage:www.elsevier.com/locate/jmbbm[Accessed: 9June2023]. [106] M. Berni et al., ‘Anisotropy and inhomogeneity of permeability and fibrous network response in the pars intermedia of the human lateral meniscus’, Acta Biomater, vol. 135, pp. 393–402, Nov. 2021 [Online]. Available: 10.1016/j.actbio.2021.08.020. [107] H. N. Chia and M. L. Hull, ‘Compressive moduli of the human medial meniscus in the axial and radial directions at equilibrium and at a physiological strain rate’, J Orthop Res, vol. 26, no. 7, pp. 951–956, Jul. 2008 [Online]. Available: 10.1002/jor.20573. [108] B. W. Leslie et al., ‘Anisotropic response of the human knee joint meniscus to unconfined compression’, Proc Inst Mech Eng H, vol. 214, no. 6, pp. 631–635, 2000 [Online]. Available: 10.1243/0954411001535651. [109] (PDF) Interspecies variation of compressive biomechanical properties of the meniscus, ResearchGate. [Online]. Available: https://www.researchgate.net/publication/15606160_Interspecies_variation_of_compressive_biomechanical_properties_of_the_meniscus. [Accessed: 09 Apr. 2025]. [110] Y. Katsuragawa et al., ‘Changes of human menisci in osteoarthritic knee joints’, Osteoarthritis Cartilage, vol. 18, no. 9, pp. 1133–1143, Sep. 2010 [Online]. Available: 10.1016/j.joca.2010.05.017. [111] A. Morejon et al., ‘Compressive Properties and Hydraulic Permeability of Human Meniscus: Relationships With Tissue Structure and Composition’, Front. Bioeng. Biotechnol., vol. 8, Feb. 2021[Online]. Availablehttps://www.frontiersin.org/journals/bioengineering-and-biotechnology/articles/10.3389/fbioe.2020.622552/full[Accessed: 9April2025]. [112] M. F. Mahmood et al., ‘Proteoglycans exert a significant effect on human meniscal stiffness through ionic effects’, Clinical Biomechanics, vol. 77, p. 105028, Jul. 2020 [Online]. Available: 10.1016/j.clinbiomech.2020.105028. [113] P. Bursac et al., ‘Influence of donor age on the biomechanical and biochemical properties of human meniscal allografts’, American Journal of Sports Medicine, vol. 37, no. 5, pp. 884–889, May 2009 [Online]. Available: 10.1177/0363546508330140. [114] M. Son et al., ‘Regional variation in T1ρ and T2 times in osteoarthritic human menisci: correlation with mechanical properties and matrix composition’, Osteoarthritis Cartilage, vol. 21, no. 6, pp. 796–805, Jun. 2013 [Online]. Available: 10.1016/j.joca.2013.03.002. [115] R. C. Nordberg et al., ‘Enhanced cellular infiltration of human adipose-derived stem cells in allograft menisci using a needle-punch method’, J Orthop Surg Res, vol. 11, no. 1, p. 132, Oct. 2016 [Online]. Available: 10.1186/s13018-016-0467-x. [116] D. Truhn et al., ‘A multi-purpose force-controlled loading device for cartilage and meniscus functionality assessment using advanced MRI techniques’, J Mech Behav Biomed Mater, vol. 101, p. 103428, Jan. 2020 [Online]. Available: 10.1016/j.jmbbm.2019.103428. [117] S. Nebelung et al., ‘Functional MRI Mapping of Human Meniscus Functionality and its Relation to Degeneration’, Sci Rep, vol. 10, no. 1, p. 2499, Feb. 2020 [Online]. Available: 10.1038/s41598-020-59573-4. [118] K. M. Fischenich et al., ‘Dynamic compression of human and ovine meniscal tissue compared with a potential thermoplastic elastomer hydrogel replacement’, J Biomed Mater Res A, vol. 105, no. 10, pp. 2722–2728, Oct. 2017 [Online]. Available: 10.1002/jbm.a.36129. [119] J. T. Moyer et al., ‘NANOINDENTATION OF HUMAN MENISCAL SURFACES’, J Biomech, vol. 45, no. 13, pp. 2230–2235, Aug. 2012 [Online]. Available: 10.1016/j.jbiomech.2012.06.017. [120] J. T. Moyer et al., ‘Indentation properties and glycosaminoglycan content of human menisci in the deep zone’, Acta Biomaterialia, vol. 9, no. 5, pp. 6624–6629, May 2013 [Online]. Available: 10.1016/j.actbio.2012.12.033. [121] A. C. Abraham and T. L. H. Donahue, ‘From meniscus to bone: a quantitative evaluation of structure and function of the human meniscal attachments’, Acta Biomater, vol. 9, no. 5, pp. 6322–6329, May 2013 [Online]. Available: 10.1016/j.actbio.2013.01.031. [122] Deleterious effects of osteoarthritis on the structure and function of the meniscal enthesis - PMC. [Online]. Available: https://pmc.ncbi.nlm.nih.gov/articles/PMC3923977/. [Accessed: 09 Apr. 2025]. [123] J. T. J. Honkanen et al., ‘Contrast enhanced imaging of human meniscus using cone beam CT’, Osteoarthritis Cartilage, vol. 23, no. 8, pp. 1367–1376, Aug. 2015 [Online]. Available: 10.1016/j.joca.2015.03.037. [124] J. Ala-Myllymäki et al., ‘Optical spectroscopic characterization of human meniscus biomechanical properties’, J Biomed Opt, vol. 22, no. 12, pp. 1–10, Dec. 2017 [Online]. Available: 10.1117/1.JBO.22.12.125008. [125] R. J. Cooper et al., ‘Development of robust finite element models of porcine tibiofemoral joints loaded under varied flexion angles and tibial freedoms’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 109, p. 103797, Sep. 2020 [Online]. Available: 10.1016/j.jmbbm.2020.103797. [126] R. Cooper et al., ‘Three subject-specific human tibiofemoral joint finite element models: complete three-dimensional imaging (CT & MR), experimental validation and modelling dataset.’ University of Leeds, 2023[Online]. Availablehttps://archive.researchdata.leeds.ac.uk/1082/[Accessed: 20July2023]. [127] G. Li et al., ‘Variability of a three-dimensional finite element model constructed using magnetic resonance images of a knee for joint contact stress analysis’, Journal of Biomechanical Engineering, vol. 123, no. 4, pp. 341–346, 2001 [Online]. Available: 10.1115/1.1385841. [128] N. Bien et al., ‘Deep-learning-assisted diagnosis for knee magnetic resonance imaging: Development and retrospective validation of MRNet’, PLoS Medicine, vol. 15, no. 11, Nov. 2018 [Online]. Available: 10.1371/journal.pmed.1002699 [Accessed: 10 August 2020]. [129] C. Herberhold et al., ‘An MR-based technique for quantifying the deformation of articular cartilage during mechanical loading in an intact cadaver joint’, Magnetic Resonance in Medicine, 1998 [Online]. Available: 10.1002/mrm.1910390522. [130] M. Freutel et al., ‘Medial meniscal displacement and strain in three dimensions under compressive loads: MR assessment’, Journal of Magnetic Resonance Imaging, vol. 40, no. 5, pp. 1181–1188, 2014 [Online]. Available: 10.1002/jmri.24461. [131] F. Eckstein et al., ‘Accuracy of cartilage volume and thickness measurements with magnetic resonance imaging’, Clinical Orthopaedics and Related Research, 1998 [Online]. Available: 10.1097/00003086-199807000-00017. [132] S. Cotofana et al., ‘In vivo measures of cartilage deformation: Patterns in healthy and osteoarthritic female knees using 3T MR imaging’, European Radiology, vol. 21, no. 6, pp. 1127–1135, Jun. 2011 [Online]. Available: 10.1007/S00330-011-2057-Y/FIGURES/4. [133] M. J. Ciarelli et al., ‘Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography.’, Journal of orthopaedic research : official publication of the Orthopaedic Research Society, vol. 9, no. 5, pp. 674–682, Sep. 1991 [Online]. Available: 10.1002/jor.1100090507. [134] P. Suetens, Fundamentals of Medical Imaging, Second Edition. 2009. [135] (Mar. 28, 2017), ‘T1, T2 and PD weighted imaging - Radiology Cafe’. [Online]. Availablehttps://www.radiologycafe.com/frcr-physics-notes/mr-imaging/t1-t2-and-pd-weighted-imaging/[Accessed: 30March2024]. [136] C. Herberhold et al., ‘In situ measurement of articular cartilage deformation in intact femoropatellar joints under static loading’, Journal of Biomechanics, vol. 32, no. 12, pp. 1287–1295, Dec. 1999 [Online]. Available: 10.1016/S0021-9290(99)00130-X. [137] T. Nishii et al., ‘Change in knee cartilage T2 in response to mechanical loading’, Journal of magnetic resonance imaging : JMRI, vol. 28, no. 1, pp. 175–180, Jul. 2008 [Online]. Available: 10.1002/JMRI.21418. [138] T. Shiomi et al., ‘Loading and knee alignment have significant influence on cartilage MRI T2 in porcine knee joints’, Osteoarthritis and Cartilage, vol. 18, no. 7, pp. 902–908, Jul. 2010 [Online]. Available: 10.1016/j.joca.2010.05.002. [139] P. Schad et al., ‘Magnetic resonance imaging of human knee joint functionality under variable compressive in-situ loading and axis alignment’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 110, no. March, p. 103890, Oct. 2020 [Online]. Available: 10.1016/j.jmbbm.2020.103890. [140] O. Said et al., ‘An MRI-compatible varus–valgus loading device for whole-knee joint functionality assessment based on compartmental compression: a proof-of-concept study’, Magnetic Resonance Materials in Physics, Biology and Medicine, vol. 33, no. 6, pp. 839–854, Dec. 2020 [Online]. Available: 10.1007/s10334-020-00844-6. [141] Y. Song et al., ‘Articular cartilage MR imaging and thickness mapping of a loaded knee joint before and after meniscectomy’, Osteoarthritis and Cartilage, 2006 [Online]. Available: 10.1016/j.joca.2006.01.011. [142] J. Yao et al., ‘Stresses and Strains in the Medial Meniscus of an ACL Deficient Knee under Anterior Loading: A Finite Element Analysis with Image-Based Experimental Validation’, Journal of Biomechanical Engineering, vol. 128, no. 1, pp. 135–141, Sep. 2005 [Online]. Available: 10.1115/1.2132373. [143] R. Patel et al., ‘Loaded versus unloaded magnetic resonance imaging (MRI) of the knee: Effect on meniscus extrusion in healthy volunteers and patients with osteoarthritis’, European Journal of Radiology Open, vol. 3, pp. 100–107, Jan. 2016 [Online]. Available: 10.1016/j.ejro.2016.05.002. [144] C. Stehling et al., ‘Loading of the knee during 3.0 T MRI is associated with significantly increased medial meniscus extrusion in mild and moderate osteoarthritis’, Eur J Radiol, vol. 81, no. 8, pp. 1839–1845, 2012 [Online]. Available: 10.1016/j.ejrad.2011.05.027. [145] F. Svensson et al., ‘Meniscal body extrusion and cartilage coverage in middle-aged and elderly without radiographic knee osteoarthritis’, European Radiology, vol. 29, pp. 1848–1854, 2019 [Online]. Available: 10.1007/s00330-018-5741-3. [146] D. L. W. Lukas Haug and M. R. and A. J. N. Daniel Haddad, Patrick Böhm, ‘Dynamic MRI Assessment of Normal Knee Kinematics’, vol. 4, no. 1, pp. 64–75, 2016 [Online]. Available: 10.21767/2471-8416.100041. [147] B. Potočnik et al., ‘A patient-specific knee joint computer model using MRI data and “in vivo” compressive load fromtheopticalforce measuring system’, Journal of Computing and Information Technology, vol. 16, no. 3, pp. 209–222, 2008 [Online]. Available: 10.2498/cit.1001126. [148] S. J. Shefelbine et al., ‘MRI analysis of in vivo meniscal and tibiofemoral kinematics in ACL-deficient and normal knees’, Journal of Orthopaedic Research, vol. 24, no. 6, pp. 1208–1217, 2006 [Online]. Available: 10.1002/jor.20139. [149] T. Yamamoto et al., ‘MRI-based kinematics of the menisci through full knee range of motion’, J Orthop Surg (Hong Kong), vol. 29, no. 2, p. 23094990211017349, May 2021 [Online]. Available: 10.1177/23094990211017349. [150] V. V. et al., ‘Meniscal movement’, https://doi.org/10.1302/0301-620X.81B1.0810037, vol. 81-B, no. 1, pp. 37–41, Jan. 1999 [Online]. Available: 10.1302/0301-620X.81B1.0810037. [151] M. Freutel et al., ‘Medial meniscal displacement and strain in three dimensions under compressive loads: MR assessment’, Journal of Magnetic Resonance Imaging, vol. 40, no. 5, pp. 1181–1188, 2014 [Online]. Available: 10.1002/jmri.24461. [152] W. O. Thompson et al., ‘Tibial meniscal dynamics using three-dimensional reconstruction of magnetic resonance images’, The American Journal of Sports Medicine, vol. 19, no. 3, pp. 210–216, 1991 [Online]. Available: 10.1177/036354659101900302. [153] S. Jerban et al., ‘Detecting Articular Cartilage and Meniscus Deformation Effects Using Magnetization Transfer Ultrashort Echo Time (MT-UTE) Modeling during Mechanical Load Application: Ex Vivo Feasibility Study’, Cartilage, vol. 13, no. 1_suppl, pp. 665S-673S, Dec. 2021 [Online]. Available: 10.1177/1947603520976771. [154] C. S. Shin et al., ‘In vivo tibiofemoral cartilage-to-cartilage contact area of females with medial osteoarthritis under acute loading using MRI’, Journal of Magnetic Resonance Imaging, vol. 34, no. 6, pp. 1405–1413, 2011 [Online]. Available: 10.1002/jmri.22796. [155] R. B. Souza et al., ‘The effects of acute loading on T1rho and T2 relaxation times of tibiofemoral articular cartilage’, Osteoarthritis and Cartilage, vol. 18, no. 12, pp. 1557–1563, Dec. 2010 [Online]. Available: 10.1016/j.joca.2010.10.001. [156] A. Norouzi et al., ‘Medical image segmentation methods, algorithms, and applications’, IETE Technical Review (Institution of Electronics and Telecommunication Engineers, India), 2014[Online]. Availablehttps://www.tandfonline.com/doi/epdf/10.1080/02564602.2014.906861?needAccess=true. [157] M. V. Wyawahare et al., ‘Image Registration Techniques : An overview’, International Journal of Signal Processing, Image Processing and Pattern Recognition, vol. 2, no. 3, pp. 11–28, 2009. [158] R. Readioff et al., ‘A full-field 3D digital image correlation and modelling technique to characterise anterior cruciate ligament mechanics ex vivo’, Acta Biomaterialia, vol. 113, pp. 417–428, Sep. 2020 [Online]. Available: 10.1016/j.actbio.2020.07.003. [159] D. A. Reiter et al., ‘Noninvasive high resolution mechanical strain maps of the spine intervertebral disc using nonrigid registration of magnetic resonance images’, Journal of Biomechanics, vol. 45, no. 8, pp. 1534–1539, May 2012 [Online]. Available: 10.1016/j.jbiomech.2012.03.005. [160] M. J. Fagan, Finite element analysis : theory and practice. Longman Scientific & Technical, 1992[Online]. Availablehttps://lib.ugent.be/en/catalog/rug01:000288014[Accessed: 14April2020]. [161] R. J. Cooper et al., ‘Finite element models of the tibiofemoral joint: A review of validation approaches and modelling challenges’, Medical Engineering and Physics, vol. 74, pp. 1–12, Dec. 2019 [Online]. Available: 10.1016/j.medengphy.2019.08.002. [162] A. C. Jones and R. K. Wilcox, ‘Finite element analysis of the spine: Towards a framework of verification, validation and sensitivity analysis’, Medical Engineering and Physics, vol. 30, no. 10, pp. 1287–1304, Dec. 2008 [Online]. Available: 10.1016/j.medengphy.2008.09.006. [163] A. Erdemir et al., ‘Deciphering the “Art” in Modeling and Simulation of the Knee Joint: Overall Strategy.’, Journal of biomechanical engineering, vol. 141, no. 7, Jul. 2019[Online]. Availablehttp://www.ncbi.nlm.nih.gov/pubmed/31166589[Accessed: 26November2020]. [164] L. P. Li et al., ‘Reconsideration on the use of elastic models to predict the instantaneous load response of the knee joint’, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 225, no. 9, pp. 888–896, Sep. 2011 [Online]. Available: 10.1177/0954411911412464. [165] K. B. Gu and L. P. Li, ‘A human knee joint model considering fluid pressure and fiber orientation in cartilages and menisci’, Medical Engineering & Physics, vol. 33, no. 4, pp. 497–503, May 2011 [Online]. Available: 10.1016/j.medengphy.2010.12.001. [166] Y. Y. Dhaher et al., ‘The effect of connective tissue material uncertainties on knee joint mechanics under isolated loading conditions’, Journal of Biomechanics, vol. 43, no. 16, pp. 3118–3125, Dec. 2010 [Online]. Available: 10.1016/j.jbiomech.2010.08.005. [167] R. Shirazi et al., ‘Role of cartilage collagen fibrils networks in knee joint biomechanics under compression’, Journal of Biomechanics, vol. 41, no. 16, pp. 3340–3348, Dec. 2008 [Online]. Available: 10.1016/j.jbiomech.2008.09.033. [168] H. Naghibi Beidokhti et al., ‘The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint’, Journal of Biomechanics, vol. 65, pp. 1–11, Dec. 2017 [Online]. Available: 10.1016/J.JBIOMECH.2017.08.030. [169] A. A. Ali et al., ‘Combined measurement and modeling of specimen-specific knee mechanics for healthy and ACL-deficient conditions’, Journal of Biomechanics, vol. 57, pp. 117–124, May 2017 [Online]. Available: 10.1016/j.jbiomech.2017.04.008. [170] L. Li and M. Kazemi, ‘Fluid Pressurization in Cartilages and Menisci in the Normal and Repaired Human Knees’, in Modeling and Simulation in Engineering, 2012[Online]. Availablewww.intechopen.com[Accessed: 31July2021]. [171] M. Kazemi et al., ‘Partial meniscectomy changes fluid pressurization in articular cartilage in human knees’, Journal of Biomechanical Engineering, vol. 134, no. 2, 2012 [Online]. Available: 10.1115/1.4005764 [Accessed: 4 July 2020]. [172] M. E. Mononen et al., ‘Effect of superficial collagen patterns and fibrillation of femoral articular cartilage on knee joint mechanics—A 3D finite element analysis’, Journal of Biomechanics, vol. 45, no. 3, pp. 579–587, Feb. 2012 [Online]. Available: 10.1016/J.JBIOMECH.2011.11.003. [173] H. Guo et al., ‘Reducing uncertainty when using knee-specific finite element models by assessing the effect of input parameters’, Journal of Orthopaedic Research, vol. 35, no. 10, pp. 2233–2242, Oct. 2017 [Online]. Available: 10.1002/JOR.23513. [174] M. E. Mononen et al., ‘Alterations in structure and properties of collagen network of osteoarthritic and repaired cartilage modify knee joint stresses’, vol. 10, no. 3, pp. 357–369. [175] H. N. Beidokhti et al., ‘The peripheral soft tissues should not be ignored in the finite element models of the human knee joint’, Medical and Biological Engineering and Computing, vol. 56, no. 7, pp. 1189–1199, 2018 [Online]. Available: 10.1007/s11517-017-1757-0. [176] M. Freutel et al., ‘Finite element modeling of soft tissues: Material models, tissue interaction and challenges’, Clinical Biomechanics, vol. 29, no. 4, pp. 363–372, Apr. 2014 [Online]. Available: 10.1016/j.clinbiomech.2014.01.006. [177] S. Butenko and P. M. Pardalos, Numerical Methods and Optimization: An Introduction. CRC Press, 2014. [178] J. Nocedal and S. Wright, Numerical Optimization. Springer Science & Business Media, 2006. [179] F. Galbusera et al., ‘Material models and properties in the finite element analysis of knee ligaments: a literature review’, 2014[Online]. Availablewww.frontiersin.org. [180] G. A. Holzapfel, ‘BIOMECH PREPRINT SERIES Biomechanics of Soft Tissue’, 2000[Online]. Availablehttp://www.cis.tu-graz.ac.at/biomech[Accessed: 3January2021]. [181] M. Grediac et al., ‘The Virtual Fields Method for Extracting Constitutive Parameters From Full-Field Measurements: a Review’[Online]. Availablehttps://onlinelibrary.wiley.com/doi/10.1111/j.1475-1305.2006.tb01504.x[Accessed: 11May2023]. [182] E. Markiewicz and B. Langrand, ‘Characterisation and Parameters Identification of Materials Constitutive and Damage Models: From Normalised Direct Approach to Most Advanced Inverse Problem Resolution’, Procedia Engineering, vol. 173, pp. 33–40, 2017 [Online]. Available: 10.1016/j.proeng.2016.12.016. [183] M. Hendriks, Identification of the mechanical behavior of solid materials, vol. 1, no. 1991. 1991 [Online]. Available: 10.6100/IR347994. [184] D. Claire et al., ‘A finite element formulation to identify damage fields: the equilibrium gap method’, International Journal for Numerical Methods in Engineering, vol. 61, no. 2, pp. 189–208, 2004 [Online]. Available: 10.1002/nme.1057. [185] B. Langrand et al., ‘Identification technique of constitutive model parameters for crashworthiness modelling’, Aerospace Science and Technology, vol. 3, no. 4, pp. 215–227, Jun. 1999 [Online]. Available: 10.1016/S1270-9638(99)80044-3. [186] A. Norouzi, Medical Image Segmentation Methods, Algorithms, and Applications. [Online]. Available: https://www.tandfonline.com/doi/epdf/10.1080/02564602.2014.906861?needAccess=true. [Accessed: 12 May 2024]. [187] P. Łuczkiewicz et al., ‘High meniscal slope angle as a risk factor for meniscal allograft extrusion’, Medical Hypotheses, vol. 101, pp. 48–51, Apr. 2017 [Online]. Available: 10.1016/J.MEHY.2017.02.003. [188] T. Liu et al., ‘The MRI-based 3D morphologic changes of knee meniscus under knee weight-bearing and early flexion conditions’, Scientific Reports, vol. 11, no. 1, Dec. 2021[Online]. Availablehttps://www.researchgate.net/publication/356149647_The_MRI-based_3D_morphologic_changes_of_knee_meniscus_under_knee_weight-bearing_and_early_flexion_conditions[Accessed: 11February2022]. [189] H. I. Inaba et al., ‘Influence of the Varus—Valgus Instability on the Contact of the Femoro-Tibial Joint’, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 204, no. 1, pp. 61–64, Mar. 1990 [Online]. Available: 10.1243/PIME_PROC_1990_204_229_02. [190] X. Lai et al., ‘LISA: Reasoning Segmentation via Large Language Model’. arXiv, Aug. 03, 2023[Online]. Availablehttp://arxiv.org/abs/2308.00692[Accessed: 18December2023]. [191] E. Peña et al., ‘Computer simulation of damage on distal femoral articular cartilage after meniscectomies’, Computers in Biology and Medicine, vol. 38, no. 1, pp. 69–81, Jan. 2008 [Online]. Available: 10.1016/j.compbiomed.2007.07.003. [192] T. L. Haut et al., ‘A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial joints’, Journal of Biomechanics, vol. 31, no. 6, pp. 571–577, Jun. 1998 [Online]. Available: 10.1016/S0021-9290(98)00049-9. [193] I. A. Anderson et al., ‘A novel method for measuring medial compartment pressures within the knee joint in-vivo’, Journal of Biomechanics, vol. 36, no. 9, pp. 1391–1395, Sep. 2003 [Online]. Available: 10.1016/S0021-9290(03)00158-1. [194] Part 4: Trends, NHS England Digital. [Online]. Available: https://digital.nhs.uk/data-and-information/publications/statistical/health-survey-for-england/2021/part-4-trends. [Accessed: 21 Feb. 2025]. [195] A. Saltelli et al., ‘Why so many published sensitivity analyses are false: A systematic review of sensitivity analysis practices’, Environmental Modelling & Software, vol. 114, pp. 29–39, Apr. 2019 [Online]. Available: 10.1016/J.ENVSOFT.2019.01.012. [196] A. Erdemir, ‘Open Knee: A Pathway to Community Driven Modeling and Simulation in Joint Biomechanics’, J Med Device, vol. 7, no. 4, p. 0409101, Dec. 2013 [Online]. Available: 10.1115/1.4025767. [197] R. J. Cooper et al., ‘The role of high-resolution cartilage thickness distribution for contact mechanics predictions in the tibiofemoral joint’, Proc Inst Mech Eng H, p. 09544119241307793, Jan. 2025 [Online]. Available: 10.1177/09544119241307793. [198] ABAQUS Analysis User’s Manual (v6.6)-Spring. [Online]. Available: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/usb/default.htm?startat=pt06ch26s01alm35.html. [Accessed: 14 May 2025]. [199] A. Liu et al., ‘Development of a specimen-specific in vitro pre-clinical simulation model of the human cadaveric knee with appropriate soft tissue constraints’, PLOS ONE, vol. 15, no. 10, p. e0238785, Oct. 2020 [Online]. Available: 10.1371/journal.pone.0238785. [200] ABAQUS/CAE User’s Manual (v6.6) - Steps. [Online]. Available: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/usi/default.htm?startat=pt03ch14s03s01.html. [Accessed: 04 Aug. 2023]. [201] K. E. Moglo and A. Shirazi-Adl, ‘Cruciate coupling and screw-home mechanism in passive knee joint during extension-flexion’, Journal of Biomechanics, vol. 38, no. 5, pp. 1075–1083, May 2005 [Online]. Available: 10.1016/j.jbiomech.2004.05.033. [202] T. L. H. Donahue et al., ‘A finite element model of the human knee joint for the study of tibio-femoral contact’, Journal of Biomechanical Engineering, vol. 124, no. 3, pp. 273–280, 2002 [Online]. Available: 10.1115/1.1470171. [203] M. Mengoni, ‘opti4Abq v 2.0.3’. Zenodo, Jun. 09, 2017[Online]. Availablehttps://zenodo.org/records/804934[Accessed: 4September2024]. [204] J. M. Peloquin et al., ‘Advances in Quantification of Meniscus Tensile Mechanics Including Nonlinearity, Yield, and Failure’, J Biomech Eng, vol. 138, no. 2, pp. 0210021–02100213, Feb. 2016 [Online]. Available: 10.1115/1.4032354. [205] Abaqus, (2023, ), Linear and nonlinear penalty contact enforcement method, Abaqus Analysis User’s Guide (6.13). [Online]. Available: http://130.149.89.49:2080/v6.13/books/usb/default.htm?startat=pt09ch38s01aus178.html. [206] P. Zellmann et al., ‘Finite Element Modelling Simulated Meniscus Translocation and Deformation during Locomotion of the Equine Stifle.’, Animals : an open access journal from MDPI, vol. 9, no. 8, Jul. 2019[Online]. Availablehttp://www.ncbi.nlm.nih.gov/pubmed/31370196[Accessed: 4July2020]. [207] D. Shriram et al., ‘Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis’, Scientific Reports 2017 7:1, vol. 7, no. 1, pp. 1–11, Jul. 2017 [Online]. Available: 10.1038/s41598-017-06271-3. [208] E. Peña et al., ‘A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint’, Journal of Biomechanics, vol. 39, no. 9, pp. 1686–1701, Jan. 2006 [Online]. Available: 10.1016/j.jbiomech.2005.04.030. [209] K.-J. Bathe, Finite Element Procedures Second Edition Bathe Finite Element Procedures Klaus-Jürgen Bathe Second Edition. 2006. [210] G. Pahl and W. Beitz, Engineering Design: A Systematic Approach. Springer Science & Business Media, 2013. [211] M. H. Gregory et al., ‘A Review of Translational Animal Models for Knee Osteoarthritis’, Arthritis, vol. 2012, no. 1, p. 764621, 2012 [Online]. Available: 10.1155/2012/764621. [212] R. McN. Alexander, ‘Bipedal animals, and their differences from humans’, Journal of Anatomy, vol. 204, no. 5, pp. 321–330, 2004 [Online]. Available: 10.1111/j.0021-8782.2004.00289.x. [213] J. Yao, ‘Mechanical Characterisation of Acetabular Soft Tissues : Experimental and Computational Study’, no. December, 2020. [214] Y. G. Koh et al., ‘Biomechanical influence of lateral meniscal allograft transplantation on knee joint mechanics during the gait cycle’, Journal of Orthopaedic Surgery and Research, vol. 14, no. 1, Sep. 2019 [Online]. Available: 10.1186/s13018-019-1347-y [Accessed: 4 July 2020]. [215] J. Schwer et al., ‘Degeneration Affects Three-Dimensional Strains in Human Menisci: In situ MRI Acquisition Combined With Image Registration’, Frontiers in Bioengineering and Biotechnology, vol. 8, no. September, pp. 1–12, 2020 [Online]. Available: 10.3389/fbioe.2020.582055. [216] National Institute for Health and Care Research (NIHR), Leeds Biomedical Research Centre. [Online]. Available: https://leedsbrc.nihr.ac.uk/. [Accessed: 14 Feb. 2025]. [217] Costs and payments, Parkside Private Patients Unit. [Online]. Available: https://www.somersetft.nhs.uk/parkside/?page_id=31&preview_id=31. [Accessed: 16 Feb. 2025]. [218] Siemens, ‘Magnetom Vida’, pp. 8–16, 2017. [219] D. Beyer et al., ‘Use of surface coils in magnetic resonance imaging of orbit and knee’, Diagn Imaging Clin Med, vol. 55, no. 1–2, pp. 84–91, 1986. [220] H. Wang et al., ‘An MRI-compatible loading device to assess knee joint cartilage deformation: Effect of preloading and inter-test repeatability’, Journal of Biomechanics, vol. 48, no. 12, pp. 2934–2940, Sep. 2015 [Online]. Available: 10.1016/j.jbiomech.2015.08.006. [221] Search for LeePTM Plastic Composite Springs | Lee Spring. [Online]. Available: https://www.leespring.com/compression-springs-leep. [Accessed: 21 Feb. 2025]. [222] G. A. Day, ‘The Effects of Vertebral Variation on the Mechanical Outcomes of Vertebroplasty’, no. December, 2018[Online]. Availablehttp://etheses.whiterose.ac.uk/23216/. [223] ‘simpleware-cad-datasheet-0322.pdf’. [Online]. Availablehttps://www.synopsys.com/content/dam/synopsys/simpleware/pdfs/simpleware-cad-datasheet-0322.pdf[Accessed: 3November2023]. [224] Z. Mohammadi and M. R. Keyvanpour, ‘Similarity Measures in Medical Image Registration A Review Article’, in 2021 12th International Conference on Information and Knowledge Technology (IKT), 2021, pp. 89–95[Online]. Availablehttps://ieeexplore.ieee.org/document/9685453[Accessed: 3November2023]. [225] Q. R. Razlighi et al., ‘Evaluating similarity measures for brain image registration’, Journal of Visual Communication and Image Representation, vol. 24, no. 7, pp. 977–987, Oct. 2013 [Online]. Available: 10.1016/j.jvcir.2013.06.010. [226] MultiStart - Find multiple local minima - MATLAB - MathWorks United Kingdom. [Online]. Available: https://uk.mathworks.com/help/gads/multistart.html. [Accessed: 13 Sep. 2024]. [227] R. Schaback and H. Wendland, ‘Kernel techniques: From machine learning to meshless methods’, Acta Numerica, vol. 15, pp. 543–639, May 2006 [Online]. Available: 10.1017/S0962492906270016. [228] A. Géron, Hands-on Machine Learning with Scikit-Learn, Keras, and TensorFlow: Concepts, Tools, and Techniques to Build Intelligent Systems. O’Reilly Media, Incorporated, 2019. [229] J. M. Párraga Quiroga et al., ‘Should a native depth-dependent distribution of human meniscus constitutive components be considered in FEA-models of the knee joint?’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 38, pp. 242–250, Oct. 2014 [Online]. Available: 10.1016/j.jmbbm.2014.03.005. [230] F. Flandry and G. Hommel, ‘Normal Anatomy and Biomechanics of the Knee’, Sports Medicine and Arthroscopy Review, vol. 19, no. 2, p. 82, Jun. 2011 [Online]. Available: 10.1097/JSA.0b013e318210c0aa."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["2444470"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/37163/1/SZ_Thesis_2024%20-%20Quantifying%20knee%20meniscus%20tissue%20behaviour.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Damage to knee meniscus tissue has been associated with the onset and progression of musculoskeletal diseases such as osteoarthritis. Through previous computational studies, the meniscus material property parameters have been found to directly affect knee contact mechanics and meniscus kinematics considered as key variables that reflect knee and meniscus health. However, characterising these properties remain challenging. Previous studies have used techniques that compromise tissue integrity, require sectioning of meniscus tissue or make compromising assumptions leading to potential inaccuracies in measurements. The aim of the study was to develop new methods to characterise meniscus mechanical properties. This involved imaging the tissue under load and using inverse finite element analysis with corresponding meniscus kinematic measurements from MRI data. A sensitivity analysis was conducted to establish meniscus radial distance sensitivity to linear transverse isotropic material property parameters. An added feature that distinguishes the current study was the study of both meniscus kinematics and contact mechanics concurrently with changes to meniscus property parameters to understand their relationship. The outcomes suggest a 3T MRI scanner of isotropic resolution ~0.3 mm would sufficiently capture meniscus kinematics and that the Efibre, Eplane and Gplane-fibre material parameters would be sufficient for capturing meniscus response in situ. Meniscus kinematics and contact mechanics were found to be linked in their response. A novel MRI-compatible loading rig was designed, built and calibrated for loading the knee joint in vitro following the finite element sensitivity analysis. The MRI-compatible rig provides for two flexion configurations (i.e., neutral and 45 degrees in flexion) and allows axial rotation, a key component relevant to the screw-home mechanism, to investigate its effect on meniscus loading and response. Meniscus radial distance measurements were obtained for various loading and knee configurations from the MR images for three porcine samples. A novel feature was that the measurements were made with reference to tibial tubercles locations such that the tibia internal-external rotations could be assumed to have no effect on the measures. Knee FE models were built, and the meniscus radial distance measurement technique replicated programmatically for material property identification purposes using the finite element method updating procedure with the particle swarm optimiser. Outcomes from the material property parameter identification study suggested consistency in the Eplane term at 20 MPa for all the three porcine samples considered. The derived Efibre term was in the range 161 MPa to 250 MPa while the Gplane-fibre term occurred in the range 13 MPa to 30 MPa. Normalised root mean squared error (NRMSE) in the range 7% to 11% was measured for the three knee samples used. Outcomes were verified using a brute force parameter identification technique. A validation study performed using meniscus radial distances obtained from a different knee configuration was deemed inconclusive due to modelling difficulties. However, a partial validation based on the medial meniscus radial distances showed NRMSE of ~9 % which was comparable to the optimised ranges. Porcine lateral meniscus kinematics were not sufficiently captured using the developed knee FE model. To conclude novel methods were developed for the non-invasive characterisation of subject-specific meniscus material property parameters using a combination of measurements from medical imaging and computational techniques. The methods developed provides for the characterisation of representative human meniscal tissue material properties and the assessment of meniscus replacement devices laying the foundations for patient stratification studies."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Quantifying knee meniscus tissue behaviour: A combined experimental and computational study"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wilcox, Ruth","Mengoni, Marlène","Wijayathunga, Nagitha","Conaghan, Philip"],"dc:contributor.sponsor":["EPSRC"],"dc:creator":["Zantiba, Sherif Abubakari"],"dc:date":["2024-11"],"dc:date.issued":["2024-11"],"dc:description.abstract":["Damage to knee meniscus tissue has been associated with the onset and progression of musculoskeletal diseases such as osteoarthritis. Through previous computational studies, the meniscus material property parameters have been found to directly affect knee contact mechanics and meniscus kinematics considered as key variables that reflect knee and meniscus health. However, characterising these properties remain challenging. Previous studies have used techniques that compromise tissue integrity, require sectioning of meniscus tissue or make compromising assumptions leading to potential inaccuracies in measurements. The aim of the study was to develop new methods to characterise meniscus mechanical properties. This involved imaging the tissue under load and using inverse finite element analysis with corresponding meniscus kinematic measurements from MRI data. A sensitivity analysis was conducted to establish meniscus radial distance sensitivity to linear transverse isotropic material property parameters. An added feature that distinguishes the current study was the study of both meniscus kinematics and contact mechanics concurrently with changes to meniscus property parameters to understand their relationship. The outcomes suggest a 3T MRI scanner of isotropic resolution ~0.3 mm would sufficiently capture meniscus kinematics and that the Efibre, Eplane and Gplane-fibre material parameters would be sufficient for capturing meniscus response in situ. Meniscus kinematics and contact mechanics were found to be linked in their response. A novel MRI-compatible loading rig was designed, built and calibrated for loading the knee joint in vitro following the finite element sensitivity analysis. The MRI-compatible rig provides for two flexion configurations (i.e., neutral and 45 degrees in flexion) and allows axial rotation, a key component relevant to the screw-home mechanism, to investigate its effect on meniscus loading and response. Meniscus radial distance measurements were obtained for various loading and knee configurations from the MR images for three porcine samples. A novel feature was that the measurements were made with reference to tibial tubercles locations such that the tibia internal-external rotations could be assumed to have no effect on the measures. Knee FE models were built, and the meniscus radial distance measurement technique replicated programmatically for material property identification purposes using the finite element method updating procedure with the particle swarm optimiser. Outcomes from the material property parameter identification study suggested consistency in the Eplane term at 20 MPa for all the three porcine samples considered. The derived Efibre term was in the range 161 MPa to 250 MPa while the Gplane-fibre term occurred in the range 13 MPa to 30 MPa. Normalised root mean squared error (NRMSE) in the range 7% to 11% was measured for the three knee samples used. Outcomes were verified using a brute force parameter identification technique. A validation study performed using meniscus radial distances obtained from a different knee configuration was deemed inconclusive due to modelling difficulties. However, a partial validation based on the medial meniscus radial distances showed NRMSE of ~9 % which was comparable to the optimised ranges. Porcine lateral meniscus kinematics were not sufficiently captured using the developed knee FE model. To conclude novel methods were developed for the non-invasive characterisation of subject-specific meniscus material property parameters using a combination of measurements from medical imaging and computational techniques. The methods developed provides for the characterisation of representative human meniscal tissue material properties and the assessment of meniscus replacement devices laying the foundations for patient stratification studies."],"dc:format":["text"],"dc:identifier.grantnumber":["2444470"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/37163/1/SZ_Thesis_2024%20-%20Quantifying%20knee%20meniscus%20tissue%20behaviour.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Mechanical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/37163/"],"dc:relation.references":["[1] NHS England » Musculoskeletal health. [Online]. Available: https://www.england.nhs.uk/elective-care-transformation/best-practice-solutions/musculoskeletal/. [Accessed: 14 Oct. 2024]. [2] E. Biver et al., ‘Gut microbiota and osteoarthritis management: An expert consensus of the European society for clinical and economic aspects of osteoporosis, osteoarthritis and musculoskeletal diseases (ESCEO)’, Ageing Research Reviews, vol. 55, p. 100946, Nov. 2019 [Online]. Available: 10.1016/j.arr.2019.100946. [3] S. Jerban et al., ‘Magnetic resonance imaging (MRI) studies of knee joint under mechanical loading: Review’, Magnetic Resonance Imaging, vol. 65, no. August 2019, pp. 27–36, 2020 [Online]. Available: 10.1016/j.mri.2019.09.007. [4] V. L. Johnson and D. J. Hunter, ‘The epidemiology of osteoarthritis’, Best Practice and Research: Clinical Rheumatology, vol. 28, no. 1, pp. 5–15, Feb. 2014 [Online]. Available: 10.1016/j.berh.2014.01.004. [5] K. M. Fischenich et al., ‘Chronic changes in the articular cartilage and meniscus following traumatic impact to the lapine knee’, J Biomech, vol. 48, no. 2, pp. 246–253, Jan. 2015 [Online]. Available: 10.1016/j.jbiomech.2014.11.038. [6] S. Fathy and M. El Messiry, ‘Study of the Effect of Cyclic Stress on the Mechanical Properties of Braided Anterior Cruciate Ligament (ACL)’, Journal of Textile Science & Engineering, vol. 06, no. 02, 2016 [Online]. Available: 10.4172/2165-8064.1000252 [Accessed: 22 January 2021]. [7] Z. Trad et al., ‘Finite element models of the knee joint’, in SpringerBriefs in Applied Sciences and Technology, no. 9783319741574, Springer Verlag, 2018, pp. 1–34 [Online]. Available: 10.1007/978-3-319-74158-1_1 [Accessed: 18 November 2020]. [8] L. S. Lohmander et al., ‘The long-term consequence of anterior cruciate ligament and meniscus injuries: Osteoarthritis’, American Journal of Sports Medicine, vol. 35, no. 10, pp. 1756–1769, Oct. 2007 [Online]. Available: 10.1177/0363546507307396. [9] A. J. S. Fox et al., ‘The Basic Science of Human Knee Menisci: Structure, Composition, and Function’, Sports Health, vol. 4, no. 4, pp. 340–351, Jul. 2012 [Online]. Available: 10.1177/1941738111429419. [10] A. J. S. Fox et al., ‘The human meniscus: A review of anatomy, function, injury, and advances in treatment’, Clinical Anatomy, vol. 28, no. 2, pp. 269–287, 2015 [Online]. Available: 10.1002/ca.22456. [11] C. Scotti et al., ‘Meniscus repair and regeneration: review on current methods and research potential’, European Cells and Materials, vol. 26, pp. 150–170, Sep. 2013 [Online]. Available: 10.22203/eCM.v026a11. [12] L. R. Shelton, ‘A closer look at osteoarthritis’, Nurse Practitioner, vol. 38, no. 7, pp. 30–36, Jul. 2013 [Online]. Available: 10.1097/01.NPR.0000431178.49311.42. [13] M. Englund et al., ‘The Role of the Meniscus in Knee Osteoar thritis : a Cause or Consequence?’ [Online]. Available: 10.1016/j.rcl.2009.03.003 [Accessed: 28 July 2021]. [14] T. J. Fairbank, ‘Knee joint changes after meniscectomy.’, The Journal of bone and joint surgery. American volume, vol. 30 B, no. 4, pp. 664–670, 1948 [Online]. Available: 10.1302/0301-620x.30b4.664. [15] A. M. Seitz et al., ‘Osteoarthritis-Related Degeneration Alters the Biomechanical Properties of Human Menisci Before the Articular Cartilage’, Frontiers in Bioengineering and Biotechnology, vol. 9, May 2021 [Online]. Available: 10.3389/FBIOE.2021.659989 [Accessed: 28 July 2021]. [16] C. A. Murphy et al., ‘The Meniscus in Normal and Osteoarthritic Tissues: Facing the Structure Property Challenges and Current Treatment Trends’, Annual Review of Biomedical Engineering, vol. 21, no. 1, pp. 495–521, Jun. 2019 [Online]. Available: 10.1146/annurev-bioeng-060418. [17] K. Messner and J. Gao, ‘The menisci of the knee joint. Anatomical and functional characteristics, and a rationale for clinical treatment’, Journal of Anatomy, vol. 193, no. 2, pp. 161–178, Aug. 1998 [Online]. Available: 10.1046/j.1469-7580.1998.19320161.x. [18] I. D. Hutchinson et al., ‘Restoration of the meniscus: Form and function’, American Journal of Sports Medicine, vol. 42, no. 4, pp. 987–998, Apr. 2014 [Online]. Available: 10.1177/0363546513498503. [19] A. C. T. Vrancken et al., ‘3D geometry analysis of the medial meniscus - A statistical shape modeling approach’, Journal of Anatomy, vol. 225, no. 4, pp. 395–402, 2014 [Online]. Available: 10.1111/joa.12223. [20] J. J. Elsner et al., ‘Mri-based characterization of bone anatomy in the human knee for size matching of a medial meniscal implant’, Journal of Biomechanical Engineering, vol. 132, no. 10, pp. 1–11, 2010 [Online]. Available: 10.1115/1.4002490. [21] P. Łuczkiewicz et al., ‘Influence of meniscus shape in the cross sectional plane on the knee contact mechanics’, Journal of Biomechanics, vol. 48, no. 8, pp. 1356–1363, Jun. 2015 [Online]. Available: 10.1016/J.JBIOMECH.2015.03.002. [22] J. R. Meakin et al., ‘Finite element analysis of the meniscus: The influence of geometry and material properties on its behaviour’, Knee, vol. 10, no. 1, pp. 33–41, Mar. 2003 [Online]. Available: 10.1016/S0968-0160(02)00106-0. [23] Q. Meng et al., ‘The effects of geometric uncertainties on computational modelling of knee biomechanics’, Royal Society Open Science, vol. 4, no. 8, p. 170670, Aug. 2017 [Online]. Available: 10.1098/rsos.170670. [24] J. Yao et al., ‘Effect of meniscus modelling assumptions in a static tibiofemoral finite element model: importance of geometry over material’, Biomech Model Mechanobiol, vol. 23, no. 3, pp. 1055–1065, Jun. 2024 [Online]. Available: 10.1007/s10237-024-01822-w. [25] K. N. Hauch et al., ‘Geometry, time-dependent and failure properties of human meniscal attachments’[Online]. Availablewww.elsevier.com/locate/jbiomech[Accessed: 9June2023]. [26] D. Kohn and B. Moreno, ‘Meniscus insertion anatomy as a basis for meniscus replacement: A morphological cadaveric study’, Arthroscopy: The Journal of Arthroscopic and Related Surgery, vol. 11, no. 1, pp. 96–103, Feb. 1995 [Online]. Available: 10.1016/0749-8063(95)90095-0. [27] E. K. Danso et al., ‘Characterization of site-specific biomechanical properties of human meniscus-Importance of collagen and fluid on mechanical nonlinearities’, Journal of Biomechanics, vol. 48, no. 8, pp. 1499–1507, Jun. 2015 [Online]. Available: 10.1016/j.jbiomech.2015.01.048. [28] E. K. Danso et al., ‘Comparison of nonlinear mechanical properties of bovine articular cartilage and meniscus’, Journal of Biomechanics, vol. 47, no. 1, pp. 200–206, Jan. 2014 [Online]. Available: 10.1016/j.jbiomech.2013.09.015. [29] K. Lechner et al., ‘Is the circumferential tensile modulus within a human medial meniscus affected by the test sample location and cross-sectional area?’, Journal of Orthopaedic Research, vol. 18, no. 6, pp. 945–951, Jan. 2000 [Online]. Available: 10.1002/JOR.1100180614. [30] D. C. Fithian et al., ‘Material Properties and Structure-Function Relationships in the Menisci’, Clinical Orthopaedics and Related Research®, vol. 252, p. 19, Mar. 1990. [31] C. S. Proctor et al., ‘Material properties of the normal medial bovine meniscus’, Journal of Orthopaedic Research, vol. 7, no. 6, pp. 771–782, 1989 [Online]. Available: 10.1002/jor.1100070602. [32] J. M. Peloquin et al., ‘Advances in quantification of meniscus tensile mechanics including nonlinearity, yield, and failure’, Journal of Biomechanical Engineering, vol. 138, no. 2, Feb. 2016 [Online]. Available: 10.1115/1.4032354 [Accessed: 12 March 2023]. [33] M. Tissakht and A. M. Ahmed, ‘Tensile stress-strain characteristics of the human meniscal material’, Journal of Biomechanics, vol. 28, no. 4, pp. 411–422, 1995 [Online]. Available: 10.1016/0021-9290(94)00081-E. [34] M. L. Tanaka et al., ‘Comparison of Biomechanical Properties of Native Menisci and Bacterial Cellulose Implant’, International Journal of Polymeric Materials and Polymeric Biomaterials, vol. 63, no. 17, pp. 891–897, Nov. 2014 [Online]. Available: 10.1080/00914037.2014.886226. [35] T. L. Haut Donahue et al., ‘How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint’, Journal of Biomechanics, vol. 36, no. 1, pp. 19–34, Jan. 2003 [Online]. Available: 10.1016/S0021-9290(02)00305-6. [36] J. Yao et al., ‘Sensitivities of Medial Meniscal Motion and Deformation to Material Properties of Articular Cartilage, Meniscus and Meniscal Attachments Using Design of Experiments Methods’, Journal of Biomechanical Engineering, vol. 128, no. 3, pp. 399–408, Dec. 2005 [Online]. Available: 10.1115/1.2191077. [37] M. Mengoni, ‘Using inverse finite element analysis to identify spinal tissue behaviour in situ’, Methods, vol. 185, pp. 105–109, Jan. 2020 [Online]. Available: 10.1016/j.ymeth.2020.02.004. [38] T. Simkheada et al., ‘Comparison of constitutive models for meniscus and their effect on the knee joint biomechanics during gait’, Computer Methods in Biomechanics and Biomedical Engineering, vol. 0, no. 0, pp. 1–14, 2022 [Online]. Available: 10.1080/10255842.2022.2163587. [39] B. B. Wheatley et al., ‘An optimized transversely isotropic, hyper-poro-viscoelastic finite element model of the meniscus to evaluate mechanical degradation following traumatic loading’, Journal of Biomechanics, vol. 48, no. 8, pp. 1454–1460, Jun. 2015 [Online]. Available: 10.1016/J.JBIOMECH.2015.02.028. [40] B. Seyfi et al., ‘Mechanical modeling and characterization of meniscus tissue using flat punch indentation and inverse finite element method’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 77, pp. 337–346, Jan. 2018 [Online]. Available: 10.1016/J.JMBBM.2017.09.023. [41] M. A. Sweigart et al., ‘Intraspecies and Interspecies Comparison of the Compressive Properties of the Medial Meniscus’, Annals of Biomedical Engineering, vol. 32, no. 11, pp. 1569–1579, Nov. 2004 [Online]. Available: 10.1114/B:ABME.0000049040.70767.5c. [42] M. De Rosa et al., ‘Mechanical properties of meniscal circumferential fibers using an inverse finite element analysis approach’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 126, p. 105073, Feb. 2022 [Online]. Available: 10.1016/j.jmbbm.2022.105073. [43] M. Freutel et al., ‘Material properties of individual menisci and their attachments obtained through inverse FE-analysis’[Online]. Availablehttp://dx.doi.org/10.1016/j.jbiomech.2015.03.014. [44] E. Peña et al., ‘Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics’, Clinical Biomechanics, vol. 20, no. 5, pp. 498–507, 2005 [Online]. Available: 10.1016/j.clinbiomech.2005.01.009. [45] B. B. Avants et al., ‘A reproducible evaluation of ANTs similarity metric performance in brain image registration’, NeuroImage, vol. 54, no. 3, pp. 2033–2044, Feb. 2011 [Online]. Available: 10.1016/j.neuroimage.2010.09.025. [46] R. J. Cooper et al., ‘Three subject-specific human tibiofemoral joint finite element models: complete three-dimensional imaging (CT & MR), experimental validation and modelling dataset.’, [Dataset], 2023[Online]. Availablehttps://archive.researchdata.leeds.ac.uk/1082/[Accessed: 19June2023]. [47] R. Readiof et al., ‘Replicating the mechanical environment of an experimental natural knee simulator in specimen-specific tibiofemoral finite element models for the study of menisci.’, in 17th International Symposium on Computational Methods in Biomechanics and Biomedical Engineering and 5th Conference on Imaging and Visualisation., Germany, 2021. [48] V. Sanchis-Alfonso et al., ‘Evaluation of Patellar Contact Pressure Changes after Static versus Dynamic Medial Patellofemoral Ligament Reconstructions Using a Finite Element Model’, Journal of Clinical Medicine, vol. 8, no. 12, p. 2093, Dec. 2019 [Online]. Available: 10.3390/jcm8122093. [49] K. A. Athanasiou and J. Sanchez-Adams, ‘Synthesis Lectures on Tissue Engineering Engineering the Knee Meniscus’, 2009[Online]. Availablewww.morganclaypool.com[Accessed: 10August2020]. [50] E. S. Grood et al., ‘Ligamentous Medial and Capsular Laxity Restraints in Intact’, The Journal of Bone and Joint Surgery, vol. 63, no. 8, pp. 1257–1269, 1981. [51] S. D. Masouros et al., ‘(i) Biomechanics of the knee joint’, Orthopaedics and Trauma, vol. 24, no. 2, pp. 84–91, Apr. 2010 [Online]. Available: 10.1016/j.mporth.2010.03.005. [52] C. M. Gupte et al., ‘The meniscofemoral ligaments: Secondary restraints to the posterior drawer’, Journal of Bone and Joint Surgery - Series B, vol. 85, no. 5, pp. 765–773, Jul. 2003 [Online]. Available: 10.1302/0301-620x.85b5.13771. [53] S. Knecht et al., ‘A review on the mechanical quality of articular cartilage - Implications for the diagnosis of osteoarthritis’, Clinical Biomechanics, vol. 21, no. 10, pp. 999–1012, Dec. 2006 [Online]. Available: 10.1016/j.clinbiomech.2006.07.001. [54] J. R. Ralphs and M. Benjamin, ‘The joint capsule: structure, composition, ageing and disease*’, 1994. [55] N. Caplan and D. F. Kader, ‘Ligamentous restraints to anterior-posterior drawer in the human knee: A biomechanical study’, in Classic Papers in Orthopaedics, 2014, pp. 141–143[Online]. Availablewww.ejbjs.org[Accessed: 14December2020]. [56] K. Tanifuji et al., ‘Three-dimensional computed tomography confirmed that the meniscal root attachments and meniscofemoral ligaments are morphologically consistent’, Knee Surgery, Sports Traumatology, Arthroscopy, vol. 28, pp. 3450–3456, 2020 [Online]. Available: 10.1007/s00167-020-06095-1. [57] P. S. Walker and J. V. Hajek, ‘The load-bearing area in the knee joint’, Journal of Biomechanics, vol. 5, no. 6, pp. 581–589, Nov. 1972 [Online]. Available: 10.1016/0021-9290(72)90030-9. [58] W. I. Hammer, Functional Soft Tissue Examination and Treatment by Manual Methods: New Perspectives. Jones and Bartlett Publishers, 2005[Online]. Availablehttps://books.google.co.uk/books?id=4b5Dy_clARAC. [59] D. J. Hunter and S. Bierma-Zeinstra, ‘Osteoarthritis’, The Lancet, vol. 393, no. 10182, pp. 1745–1759, Apr. 2019 [Online]. Available: 10.1016/S0140-6736(19)30417-9. [60] E. Rath and J. C. Richmond, ‘The menisci: basic science and advances in treatment’[Online]. Availablehttp://bjsm.bmj.com/[Accessed: 3December2020]. [61] P. S. Walker and M. J. Erkman, ‘The role of the menisci in force transmission across the knee’, CLIN.ORTHOP., vol. No. 109, pp. 184–192, 1975 [Online]. Available: 10.1097/00003086-197506000-00027. [62] B. B. Seedhom and D. J. Hargreaves, ‘Transmission of the load in the knee joint with special reference to the role of the menisci PART II: experimental results, discussion and conclusions Experimental work Specimens and test conditions’, 1979. [63] E. A. Makris et al., ‘The knee meniscus: Structure-function, pathophysiology, current repair techniques, and prospects for regeneration’, Biomaterials, vol. 32, no. 30, pp. 7411–7431, Oct. 2011 [Online]. Available: 10.1016/j.biomaterials.2011.06.037. [64] I. D. McDermott et al., ‘An anatomical study of meniscal allograft sizing’, Knee Surgery, Sports Traumatology, Arthroscopy, vol. 12, no. 2, pp. 130–135, Mar. 2004 [Online]. Available: 10.1007/s00167-003-0366-7. [65] T. Takroni et al., ‘Anatomical study: comparing the human, sheep and pig knee meniscus’, Journal of Experimental Orthopaedics, vol. 3, no. 1, 2016[Online]. Availablehttp://dx.doi.org/10.1186/s40634-016-0071-3. [66] B. L. Proffen et al., ‘A comparative anatomical study of the human knee and six animal species’, Knee, vol. 19, no. 4, pp. 493–499, Aug. 2012 [Online]. Available: 10.1016/j.knee.2011.07.005. [67] E. S. Mameri et al., ‘Review of Meniscus Anatomy and Biomechanics’, Current Reviews in Musculoskeletal Medicine, vol. 15, no. 5, p. 323, Aug. 2022 [Online]. Available: 10.1007/s12178-022-09768-1. [68] D. L. Johnson et al., ‘Insertion-site anatomy of the human menisci: Gross, arthroscopic, and topographical anatomy as a basis for meniscal transplantation’, Arthroscopy: The Journal of Arthroscopic and Related Surgery, vol. 11, no. 4, pp. 386–394, Aug. 1995 [Online]. Available: 10.1016/0749-8063(95)90188-4. [69] D. C. Fithian et al., ‘Material properties and structure-function relationships in the menisci’, Clin Orthop Relat Res, no. 252, pp. 19–31, Mar. 1990. [70] M. A. Sweigart and K. A. Athanasiou, ‘Toward tissue engineering of the knee meniscus’, in Tissue Engineering, 2001, vol. 7, no. 2, pp. 111–129[Online]. Availablehttps://www.liebertpub.com/doi/abs/10.1089/107632701300062697[Accessed: 3December2020]. [71] D. L. Skaggs et al., ‘Radial tie fibers influence the tensile properties of the bovine medial meniscus’, Journal of Orthopaedic Research, vol. 12, no. 2, pp. 176–185, Mar. 1994 [Online]. Available: 10.1002/jor.1100120205. [72] C. M. Gupte et al., ‘Meniscofemoral ligaments revisited’, The Journal of Bone and Joint Surgery. British volume, vol. 84-B, no. 6, pp. 846–851, Aug. 2002 [Online]. Available: 10.1302/0301-620x.84b6.0840846. [73] J. Herwig et al., ‘Chemical changes of human knee joint menisci in various stages of degeneration’, Annals of the Rheumatic Diseases, vol. 43, no. 4, pp. 635–640, Aug. 1984 [Online]. Available: 10.1136/ard.43.4.635. [74] M. Imeni et al., ‘Constitutive modeling of menisci tissue: a critical review of analytical and numerical approaches’, Biomechanics and Modeling in Mechanobiology, vol. 19, no. 6, pp. 1979–1996, Dec. 2020 [Online]. Available: 10.1007/s10237-020-01352-1. [75] N. G. Shrive et al., ‘Load-bearing in the knee joint’, Clinical Orthopaedics and Related Research, vol. NO.131, no. 131, pp. 279–287, Mar. 1978 [Online]. Available: 10.1097/00003086-197803000-00046. [76] J. Melrose et al., ‘The biology of meniscal pathology in osteoarthritis and its contribution to joint disease: beyond simple mechanics’, CONNECTIVE TISSUE RESEARCH, vol. 58, no. 3–4, SI, pp. 282–294, 2017 [Online]. Available: 10.1080/03008207.2017.1284824. [77] M. Benjamin et al., ‘Quantitative differences in the histology of the attachment zones of the meniscal horns in the knee joint of man.’, Journal of anatomy, vol. 177, pp. 127–34, Aug. 1991. [78] T. J. A. Mommersteeg et al., ‘Nonuniform distribution of collagen density in human knee ligaments’, Journal of Orthopaedic Research, vol. 12, no. 2, pp. 238–245, Mar. 1994 [Online]. Available: 10.1002/jor.1100120213. [79] C. M. Disney et al., ‘A review of techniques for visualising soft tissue microstructure deformation and quantifying strain Ex Vivo’, Journal of Microscopy, vol. 272, no. 3, pp. 165–179, Dec. 2018 [Online]. Available: 10.1111/jmi.12701. [80] J. Schwer et al., The biomechanical properties of human menisci: A systematic review - ScienceDirect. [Online]. Available: https://www.sciencedirect.com/science/article/pii/S1742706123007146?fr=RR-2&ref=pdf_download&rr=88c7cb130d7c2213. [Accessed: 31 May 2024]. [81] M. Kazemi et al., ‘Recent advances in computational mechanics of the human knee joint’, Computational and Mathematical Methods in Medicine, vol. 2013, p. 28, 2013 [Online]. Available: 10.1155/2013/718423. [82] E. Donnelly, ‘Methods for assessing bone quality: A review’, in Clinical Orthopaedics and Related Research, 2011, vol. 469, no. 8, pp. 2128–2138[Online]. Availablehttps://www.ncbi.nlm.nih.gov/pubmed/21116752[Accessed: 5December2019]. [83] S. E. Arevalo et al., ‘A methodological framework for nanomechanical characterization of soft biomaterials and polymers’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 134, p. 105384, Oct. 2022 [Online]. Available: 10.1016/j.jmbbm.2022.105384. [84] T. C. Gasser et al., ‘Hyperelastic modelling of arterial layers with distributed collagen fibre orientations’, Journal of the Royal Society Interface, vol. 3, no. 6, pp. 15–35, 2006 [Online]. Available: 10.1098/rsif.2005.0073. [85] G. A. Holzapfel et al., ‘A new constitutive framework for arterial wall mechanics and a comparative study of material models’, Journal of Elasticity, vol. 61, no. 1–3, pp. 1–48, 2000 [Online]. Available: 10.1023/A:1010835316564. [86] M. Mengoni et al., ‘Annulus fibrosus functional extrafibrillar and fibrous mechanical behaviour: Experimental and computational characterisation’, Royal Society Open Science, vol. 4, no. 8, Aug. 2017 [Online]. Available: 10.1098/rsos.170807 [Accessed: 9 October 2020]. [87] K. Navindaran et al., ‘Techniques for characterizing mechanical properties of soft tissues’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 138, p. 105575, Feb. 2023 [Online]. Available: 10.1016/j.jmbbm.2022.105575. [88] P. B. Lewis et al., ‘Multiple freeze-thaw cycled meniscal allograft tissue: A biomechanical, biochemical, and histologic analysis’, J Orthop Res, vol. 26, no. 1, pp. 49–55, Jan. 2008 [Online]. Available: 10.1002/jor.20473. [89] S. Ahmad et al., ‘Cryopreservation versus fresh frozen meniscal allograft: A biomechanical comparative analysis’, J Orthop Surg (Hong Kong), vol. 25, no. 3, p. 2309499017727946, Sep. 2017 [Online]. Available: 10.1177/2309499017727946. [90] A. C. Abraham et al., ‘Hyperelastic properties of human meniscal attachments’, Journal of Biomechanics, vol. 44, no. 3, pp. 413–418, Feb. 2011 [Online]. Available: 10.1016/j.jbiomech.2010.10.001. [91] P. G. Bullough et al., ‘The strength of the menisci of the knee as it relates to their fine structure’, J Bone Joint Surg Br, vol. 52, no. 3, pp. 564–567, Aug. 1970. [92] D. Q. Nesbitt et al., ‘Effect of age on the failure properties of human meniscus: high-speed strain mapping of tissue tears’, Journal of Biomechanics, p. 110126, 2020 [Online]. Available: 10.1016/j.jbiomech.2020.110126. [93] D. Warnecke et al., ‘Degeneration alters the biomechanical properties and structural composition of lateral human menisci’, Osteoarthritis Cartilage, vol. 28, no. 11, pp. 1482–1491, Nov. 2020 [Online]. Available: 10.1016/j.joca.2020.07.004. [94] M. Freutel et al., ‘Mechanical properties and morphological analysis of the transitional zone between meniscal body and ligamentous meniscal attachments’, Journal of Biomechanics, vol. 48, no. 8, pp. 1350–1355, Jun. 2015 [Online]. Available: 10.1016/j.jbiomech.2015.03.003. [95] B. S. Henderson et al., ‘Tensile fatigue strength and endurance limit of human meniscus’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 127, p. 105057, Mar. 2022 [Online]. Available: 10.1016/j.jmbbm.2021.105057. [96] K. M. Fischenich et al., ‘Effects of degeneration on the compressive and tensile properties of human meniscus’, J Biomech, vol. 48, no. 8, pp. 1407–1411, Jun. 2015 [Online]. Available: 10.1016/j.jbiomech.2015.02.042. [97] X. Y. Yin et al., ‘The Perimensical Capsule: Potential Supporting Structure Surrounding Meniscus’, CARTILAGE, vol. 13, no. 1_suppl, pp. 208S-215S, Dec. 2021 [Online]. Available: 10.1177/1947603519892316. [98] J. M. Párraga Quiroga et al., ‘Should a native depth-dependent distribution of human meniscus constitutive components be considered in FEA-models of the knee joint?’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 38, pp. 242–250, Oct. 2014 [Online]. Available: 10.1016/j.jmbbm.2014.03.005. [99] C. Jacquet et al., ‘Preservation Methods Influence the Biomechanical Properties of Human Lateral Menisci: An Ex Vivo Comparative Study of 3 Methods’, Orthopaedic Journal of Sports Medicine, vol. 7, no. 4, p. 2325967119841622, Apr. 2019 [Online]. Available: 10.1177/2325967119841622. [100] S. Yan et al., ‘Tensile biomechanical characteristics of human meniscus’, Emerging Materials Research, vol. 5, pp. 1–6, Jun. 2016 [Online]. Available: 10.1680/jemmr.15.00031. [101] J. D. Finan et al., ‘Non-ideal effects in indentation testing of soft tissues’, Biomech Model Mechanobiol, vol. 13, no. 3, pp. 573–584, Jun. 2014 [Online]. Available: 10.1007/s10237-013-0519-7. [102] A. E. Peters et al., ‘Tissue material properties and computational modelling of the human tibiofemoral joint: A critical review’, PeerJ, vol. 2018, no. 1, 2018[Online]. Availablehttps://pubmed.ncbi.nlm.nih.gov/29379690/[Accessed: 26November2020]. [103] A. M. Seitz et al., ‘Stress-relaxation response of human menisci under confined compression conditions’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 26, pp. 68–80, Oct. 2013 [Online]. Available: 10.1016/j.jmbbm.2013.05.027. [104] T. Long et al., ‘Experiments and hyperelastic modeling of porcine meniscus show heterogeneity at high strains’, Biomech Model Mechanobiol, vol. 21, no. 6, pp. 1641–1658, Dec. 2022 [Online]. Available: 10.1007/s10237-022-01611-3. [105] K. N. Hauch et al., ‘Nanoindentation of the insertional zones of human meniscal attachments into underlying bone’, 2008[Online]. Availablewww.sciencedirect.comjournalhomepage:www.elsevier.com/locate/jmbbm[Accessed: 9June2023]. [106] M. Berni et al., ‘Anisotropy and inhomogeneity of permeability and fibrous network response in the pars intermedia of the human lateral meniscus’, Acta Biomater, vol. 135, pp. 393–402, Nov. 2021 [Online]. Available: 10.1016/j.actbio.2021.08.020. [107] H. N. Chia and M. L. Hull, ‘Compressive moduli of the human medial meniscus in the axial and radial directions at equilibrium and at a physiological strain rate’, J Orthop Res, vol. 26, no. 7, pp. 951–956, Jul. 2008 [Online]. Available: 10.1002/jor.20573. [108] B. W. Leslie et al., ‘Anisotropic response of the human knee joint meniscus to unconfined compression’, Proc Inst Mech Eng H, vol. 214, no. 6, pp. 631–635, 2000 [Online]. Available: 10.1243/0954411001535651. [109] (PDF) Interspecies variation of compressive biomechanical properties of the meniscus, ResearchGate. [Online]. Available: https://www.researchgate.net/publication/15606160_Interspecies_variation_of_compressive_biomechanical_properties_of_the_meniscus. [Accessed: 09 Apr. 2025]. [110] Y. Katsuragawa et al., ‘Changes of human menisci in osteoarthritic knee joints’, Osteoarthritis Cartilage, vol. 18, no. 9, pp. 1133–1143, Sep. 2010 [Online]. Available: 10.1016/j.joca.2010.05.017. [111] A. Morejon et al., ‘Compressive Properties and Hydraulic Permeability of Human Meniscus: Relationships With Tissue Structure and Composition’, Front. Bioeng. Biotechnol., vol. 8, Feb. 2021[Online]. Availablehttps://www.frontiersin.org/journals/bioengineering-and-biotechnology/articles/10.3389/fbioe.2020.622552/full[Accessed: 9April2025]. [112] M. F. Mahmood et al., ‘Proteoglycans exert a significant effect on human meniscal stiffness through ionic effects’, Clinical Biomechanics, vol. 77, p. 105028, Jul. 2020 [Online]. Available: 10.1016/j.clinbiomech.2020.105028. [113] P. Bursac et al., ‘Influence of donor age on the biomechanical and biochemical properties of human meniscal allografts’, American Journal of Sports Medicine, vol. 37, no. 5, pp. 884–889, May 2009 [Online]. Available: 10.1177/0363546508330140. [114] M. Son et al., ‘Regional variation in T1ρ and T2 times in osteoarthritic human menisci: correlation with mechanical properties and matrix composition’, Osteoarthritis Cartilage, vol. 21, no. 6, pp. 796–805, Jun. 2013 [Online]. Available: 10.1016/j.joca.2013.03.002. [115] R. C. Nordberg et al., ‘Enhanced cellular infiltration of human adipose-derived stem cells in allograft menisci using a needle-punch method’, J Orthop Surg Res, vol. 11, no. 1, p. 132, Oct. 2016 [Online]. Available: 10.1186/s13018-016-0467-x. [116] D. Truhn et al., ‘A multi-purpose force-controlled loading device for cartilage and meniscus functionality assessment using advanced MRI techniques’, J Mech Behav Biomed Mater, vol. 101, p. 103428, Jan. 2020 [Online]. Available: 10.1016/j.jmbbm.2019.103428. [117] S. Nebelung et al., ‘Functional MRI Mapping of Human Meniscus Functionality and its Relation to Degeneration’, Sci Rep, vol. 10, no. 1, p. 2499, Feb. 2020 [Online]. Available: 10.1038/s41598-020-59573-4. [118] K. M. Fischenich et al., ‘Dynamic compression of human and ovine meniscal tissue compared with a potential thermoplastic elastomer hydrogel replacement’, J Biomed Mater Res A, vol. 105, no. 10, pp. 2722–2728, Oct. 2017 [Online]. Available: 10.1002/jbm.a.36129. [119] J. T. Moyer et al., ‘NANOINDENTATION OF HUMAN MENISCAL SURFACES’, J Biomech, vol. 45, no. 13, pp. 2230–2235, Aug. 2012 [Online]. Available: 10.1016/j.jbiomech.2012.06.017. [120] J. T. Moyer et al., ‘Indentation properties and glycosaminoglycan content of human menisci in the deep zone’, Acta Biomaterialia, vol. 9, no. 5, pp. 6624–6629, May 2013 [Online]. Available: 10.1016/j.actbio.2012.12.033. [121] A. C. Abraham and T. L. H. Donahue, ‘From meniscus to bone: a quantitative evaluation of structure and function of the human meniscal attachments’, Acta Biomater, vol. 9, no. 5, pp. 6322–6329, May 2013 [Online]. Available: 10.1016/j.actbio.2013.01.031. [122] Deleterious effects of osteoarthritis on the structure and function of the meniscal enthesis - PMC. [Online]. Available: https://pmc.ncbi.nlm.nih.gov/articles/PMC3923977/. [Accessed: 09 Apr. 2025]. [123] J. T. J. Honkanen et al., ‘Contrast enhanced imaging of human meniscus using cone beam CT’, Osteoarthritis Cartilage, vol. 23, no. 8, pp. 1367–1376, Aug. 2015 [Online]. Available: 10.1016/j.joca.2015.03.037. [124] J. Ala-Myllymäki et al., ‘Optical spectroscopic characterization of human meniscus biomechanical properties’, J Biomed Opt, vol. 22, no. 12, pp. 1–10, Dec. 2017 [Online]. Available: 10.1117/1.JBO.22.12.125008. [125] R. J. Cooper et al., ‘Development of robust finite element models of porcine tibiofemoral joints loaded under varied flexion angles and tibial freedoms’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 109, p. 103797, Sep. 2020 [Online]. Available: 10.1016/j.jmbbm.2020.103797. [126] R. Cooper et al., ‘Three subject-specific human tibiofemoral joint finite element models: complete three-dimensional imaging (CT & MR), experimental validation and modelling dataset.’ University of Leeds, 2023[Online]. Availablehttps://archive.researchdata.leeds.ac.uk/1082/[Accessed: 20July2023]. [127] G. Li et al., ‘Variability of a three-dimensional finite element model constructed using magnetic resonance images of a knee for joint contact stress analysis’, Journal of Biomechanical Engineering, vol. 123, no. 4, pp. 341–346, 2001 [Online]. Available: 10.1115/1.1385841. [128] N. Bien et al., ‘Deep-learning-assisted diagnosis for knee magnetic resonance imaging: Development and retrospective validation of MRNet’, PLoS Medicine, vol. 15, no. 11, Nov. 2018 [Online]. Available: 10.1371/journal.pmed.1002699 [Accessed: 10 August 2020]. [129] C. Herberhold et al., ‘An MR-based technique for quantifying the deformation of articular cartilage during mechanical loading in an intact cadaver joint’, Magnetic Resonance in Medicine, 1998 [Online]. Available: 10.1002/mrm.1910390522. [130] M. Freutel et al., ‘Medial meniscal displacement and strain in three dimensions under compressive loads: MR assessment’, Journal of Magnetic Resonance Imaging, vol. 40, no. 5, pp. 1181–1188, 2014 [Online]. Available: 10.1002/jmri.24461. [131] F. Eckstein et al., ‘Accuracy of cartilage volume and thickness measurements with magnetic resonance imaging’, Clinical Orthopaedics and Related Research, 1998 [Online]. Available: 10.1097/00003086-199807000-00017. [132] S. Cotofana et al., ‘In vivo measures of cartilage deformation: Patterns in healthy and osteoarthritic female knees using 3T MR imaging’, European Radiology, vol. 21, no. 6, pp. 1127–1135, Jun. 2011 [Online]. Available: 10.1007/S00330-011-2057-Y/FIGURES/4. [133] M. J. Ciarelli et al., ‘Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography.’, Journal of orthopaedic research : official publication of the Orthopaedic Research Society, vol. 9, no. 5, pp. 674–682, Sep. 1991 [Online]. Available: 10.1002/jor.1100090507. [134] P. Suetens, Fundamentals of Medical Imaging, Second Edition. 2009. [135] (Mar. 28, 2017), ‘T1, T2 and PD weighted imaging - Radiology Cafe’. [Online]. Availablehttps://www.radiologycafe.com/frcr-physics-notes/mr-imaging/t1-t2-and-pd-weighted-imaging/[Accessed: 30March2024]. [136] C. Herberhold et al., ‘In situ measurement of articular cartilage deformation in intact femoropatellar joints under static loading’, Journal of Biomechanics, vol. 32, no. 12, pp. 1287–1295, Dec. 1999 [Online]. Available: 10.1016/S0021-9290(99)00130-X. [137] T. Nishii et al., ‘Change in knee cartilage T2 in response to mechanical loading’, Journal of magnetic resonance imaging : JMRI, vol. 28, no. 1, pp. 175–180, Jul. 2008 [Online]. Available: 10.1002/JMRI.21418. [138] T. Shiomi et al., ‘Loading and knee alignment have significant influence on cartilage MRI T2 in porcine knee joints’, Osteoarthritis and Cartilage, vol. 18, no. 7, pp. 902–908, Jul. 2010 [Online]. Available: 10.1016/j.joca.2010.05.002. [139] P. Schad et al., ‘Magnetic resonance imaging of human knee joint functionality under variable compressive in-situ loading and axis alignment’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 110, no. March, p. 103890, Oct. 2020 [Online]. Available: 10.1016/j.jmbbm.2020.103890. [140] O. Said et al., ‘An MRI-compatible varus–valgus loading device for whole-knee joint functionality assessment based on compartmental compression: a proof-of-concept study’, Magnetic Resonance Materials in Physics, Biology and Medicine, vol. 33, no. 6, pp. 839–854, Dec. 2020 [Online]. Available: 10.1007/s10334-020-00844-6. [141] Y. Song et al., ‘Articular cartilage MR imaging and thickness mapping of a loaded knee joint before and after meniscectomy’, Osteoarthritis and Cartilage, 2006 [Online]. Available: 10.1016/j.joca.2006.01.011. [142] J. Yao et al., ‘Stresses and Strains in the Medial Meniscus of an ACL Deficient Knee under Anterior Loading: A Finite Element Analysis with Image-Based Experimental Validation’, Journal of Biomechanical Engineering, vol. 128, no. 1, pp. 135–141, Sep. 2005 [Online]. Available: 10.1115/1.2132373. [143] R. Patel et al., ‘Loaded versus unloaded magnetic resonance imaging (MRI) of the knee: Effect on meniscus extrusion in healthy volunteers and patients with osteoarthritis’, European Journal of Radiology Open, vol. 3, pp. 100–107, Jan. 2016 [Online]. Available: 10.1016/j.ejro.2016.05.002. [144] C. Stehling et al., ‘Loading of the knee during 3.0 T MRI is associated with significantly increased medial meniscus extrusion in mild and moderate osteoarthritis’, Eur J Radiol, vol. 81, no. 8, pp. 1839–1845, 2012 [Online]. Available: 10.1016/j.ejrad.2011.05.027. [145] F. Svensson et al., ‘Meniscal body extrusion and cartilage coverage in middle-aged and elderly without radiographic knee osteoarthritis’, European Radiology, vol. 29, pp. 1848–1854, 2019 [Online]. Available: 10.1007/s00330-018-5741-3. [146] D. L. W. Lukas Haug and M. R. and A. J. N. Daniel Haddad, Patrick Böhm, ‘Dynamic MRI Assessment of Normal Knee Kinematics’, vol. 4, no. 1, pp. 64–75, 2016 [Online]. Available: 10.21767/2471-8416.100041. [147] B. Potočnik et al., ‘A patient-specific knee joint computer model using MRI data and “in vivo” compressive load fromtheopticalforce measuring system’, Journal of Computing and Information Technology, vol. 16, no. 3, pp. 209–222, 2008 [Online]. Available: 10.2498/cit.1001126. [148] S. J. Shefelbine et al., ‘MRI analysis of in vivo meniscal and tibiofemoral kinematics in ACL-deficient and normal knees’, Journal of Orthopaedic Research, vol. 24, no. 6, pp. 1208–1217, 2006 [Online]. Available: 10.1002/jor.20139. [149] T. Yamamoto et al., ‘MRI-based kinematics of the menisci through full knee range of motion’, J Orthop Surg (Hong Kong), vol. 29, no. 2, p. 23094990211017349, May 2021 [Online]. Available: 10.1177/23094990211017349. [150] V. V. et al., ‘Meniscal movement’, https://doi.org/10.1302/0301-620X.81B1.0810037, vol. 81-B, no. 1, pp. 37–41, Jan. 1999 [Online]. Available: 10.1302/0301-620X.81B1.0810037. [151] M. Freutel et al., ‘Medial meniscal displacement and strain in three dimensions under compressive loads: MR assessment’, Journal of Magnetic Resonance Imaging, vol. 40, no. 5, pp. 1181–1188, 2014 [Online]. Available: 10.1002/jmri.24461. [152] W. O. Thompson et al., ‘Tibial meniscal dynamics using three-dimensional reconstruction of magnetic resonance images’, The American Journal of Sports Medicine, vol. 19, no. 3, pp. 210–216, 1991 [Online]. Available: 10.1177/036354659101900302. [153] S. Jerban et al., ‘Detecting Articular Cartilage and Meniscus Deformation Effects Using Magnetization Transfer Ultrashort Echo Time (MT-UTE) Modeling during Mechanical Load Application: Ex Vivo Feasibility Study’, Cartilage, vol. 13, no. 1_suppl, pp. 665S-673S, Dec. 2021 [Online]. Available: 10.1177/1947603520976771. [154] C. S. Shin et al., ‘In vivo tibiofemoral cartilage-to-cartilage contact area of females with medial osteoarthritis under acute loading using MRI’, Journal of Magnetic Resonance Imaging, vol. 34, no. 6, pp. 1405–1413, 2011 [Online]. Available: 10.1002/jmri.22796. [155] R. B. Souza et al., ‘The effects of acute loading on T1rho and T2 relaxation times of tibiofemoral articular cartilage’, Osteoarthritis and Cartilage, vol. 18, no. 12, pp. 1557–1563, Dec. 2010 [Online]. Available: 10.1016/j.joca.2010.10.001. [156] A. Norouzi et al., ‘Medical image segmentation methods, algorithms, and applications’, IETE Technical Review (Institution of Electronics and Telecommunication Engineers, India), 2014[Online]. Availablehttps://www.tandfonline.com/doi/epdf/10.1080/02564602.2014.906861?needAccess=true. [157] M. V. Wyawahare et al., ‘Image Registration Techniques : An overview’, International Journal of Signal Processing, Image Processing and Pattern Recognition, vol. 2, no. 3, pp. 11–28, 2009. [158] R. Readioff et al., ‘A full-field 3D digital image correlation and modelling technique to characterise anterior cruciate ligament mechanics ex vivo’, Acta Biomaterialia, vol. 113, pp. 417–428, Sep. 2020 [Online]. Available: 10.1016/j.actbio.2020.07.003. [159] D. A. Reiter et al., ‘Noninvasive high resolution mechanical strain maps of the spine intervertebral disc using nonrigid registration of magnetic resonance images’, Journal of Biomechanics, vol. 45, no. 8, pp. 1534–1539, May 2012 [Online]. Available: 10.1016/j.jbiomech.2012.03.005. [160] M. J. Fagan, Finite element analysis : theory and practice. Longman Scientific & Technical, 1992[Online]. Availablehttps://lib.ugent.be/en/catalog/rug01:000288014[Accessed: 14April2020]. [161] R. J. Cooper et al., ‘Finite element models of the tibiofemoral joint: A review of validation approaches and modelling challenges’, Medical Engineering and Physics, vol. 74, pp. 1–12, Dec. 2019 [Online]. Available: 10.1016/j.medengphy.2019.08.002. [162] A. C. Jones and R. K. Wilcox, ‘Finite element analysis of the spine: Towards a framework of verification, validation and sensitivity analysis’, Medical Engineering and Physics, vol. 30, no. 10, pp. 1287–1304, Dec. 2008 [Online]. Available: 10.1016/j.medengphy.2008.09.006. [163] A. Erdemir et al., ‘Deciphering the “Art” in Modeling and Simulation of the Knee Joint: Overall Strategy.’, Journal of biomechanical engineering, vol. 141, no. 7, Jul. 2019[Online]. Availablehttp://www.ncbi.nlm.nih.gov/pubmed/31166589[Accessed: 26November2020]. [164] L. P. Li et al., ‘Reconsideration on the use of elastic models to predict the instantaneous load response of the knee joint’, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 225, no. 9, pp. 888–896, Sep. 2011 [Online]. Available: 10.1177/0954411911412464. [165] K. B. Gu and L. P. Li, ‘A human knee joint model considering fluid pressure and fiber orientation in cartilages and menisci’, Medical Engineering & Physics, vol. 33, no. 4, pp. 497–503, May 2011 [Online]. Available: 10.1016/j.medengphy.2010.12.001. [166] Y. Y. Dhaher et al., ‘The effect of connective tissue material uncertainties on knee joint mechanics under isolated loading conditions’, Journal of Biomechanics, vol. 43, no. 16, pp. 3118–3125, Dec. 2010 [Online]. Available: 10.1016/j.jbiomech.2010.08.005. [167] R. Shirazi et al., ‘Role of cartilage collagen fibrils networks in knee joint biomechanics under compression’, Journal of Biomechanics, vol. 41, no. 16, pp. 3340–3348, Dec. 2008 [Online]. Available: 10.1016/j.jbiomech.2008.09.033. [168] H. Naghibi Beidokhti et al., ‘The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint’, Journal of Biomechanics, vol. 65, pp. 1–11, Dec. 2017 [Online]. Available: 10.1016/J.JBIOMECH.2017.08.030. [169] A. A. Ali et al., ‘Combined measurement and modeling of specimen-specific knee mechanics for healthy and ACL-deficient conditions’, Journal of Biomechanics, vol. 57, pp. 117–124, May 2017 [Online]. Available: 10.1016/j.jbiomech.2017.04.008. [170] L. Li and M. Kazemi, ‘Fluid Pressurization in Cartilages and Menisci in the Normal and Repaired Human Knees’, in Modeling and Simulation in Engineering, 2012[Online]. Availablewww.intechopen.com[Accessed: 31July2021]. [171] M. Kazemi et al., ‘Partial meniscectomy changes fluid pressurization in articular cartilage in human knees’, Journal of Biomechanical Engineering, vol. 134, no. 2, 2012 [Online]. Available: 10.1115/1.4005764 [Accessed: 4 July 2020]. [172] M. E. Mononen et al., ‘Effect of superficial collagen patterns and fibrillation of femoral articular cartilage on knee joint mechanics—A 3D finite element analysis’, Journal of Biomechanics, vol. 45, no. 3, pp. 579–587, Feb. 2012 [Online]. Available: 10.1016/J.JBIOMECH.2011.11.003. [173] H. Guo et al., ‘Reducing uncertainty when using knee-specific finite element models by assessing the effect of input parameters’, Journal of Orthopaedic Research, vol. 35, no. 10, pp. 2233–2242, Oct. 2017 [Online]. Available: 10.1002/JOR.23513. [174] M. E. Mononen et al., ‘Alterations in structure and properties of collagen network of osteoarthritic and repaired cartilage modify knee joint stresses’, vol. 10, no. 3, pp. 357–369. [175] H. N. Beidokhti et al., ‘The peripheral soft tissues should not be ignored in the finite element models of the human knee joint’, Medical and Biological Engineering and Computing, vol. 56, no. 7, pp. 1189–1199, 2018 [Online]. Available: 10.1007/s11517-017-1757-0. [176] M. Freutel et al., ‘Finite element modeling of soft tissues: Material models, tissue interaction and challenges’, Clinical Biomechanics, vol. 29, no. 4, pp. 363–372, Apr. 2014 [Online]. Available: 10.1016/j.clinbiomech.2014.01.006. [177] S. Butenko and P. M. Pardalos, Numerical Methods and Optimization: An Introduction. CRC Press, 2014. [178] J. Nocedal and S. Wright, Numerical Optimization. Springer Science & Business Media, 2006. [179] F. Galbusera et al., ‘Material models and properties in the finite element analysis of knee ligaments: a literature review’, 2014[Online]. Availablewww.frontiersin.org. [180] G. A. Holzapfel, ‘BIOMECH PREPRINT SERIES Biomechanics of Soft Tissue’, 2000[Online]. Availablehttp://www.cis.tu-graz.ac.at/biomech[Accessed: 3January2021]. [181] M. Grediac et al., ‘The Virtual Fields Method for Extracting Constitutive Parameters From Full-Field Measurements: a Review’[Online]. Availablehttps://onlinelibrary.wiley.com/doi/10.1111/j.1475-1305.2006.tb01504.x[Accessed: 11May2023]. [182] E. Markiewicz and B. Langrand, ‘Characterisation and Parameters Identification of Materials Constitutive and Damage Models: From Normalised Direct Approach to Most Advanced Inverse Problem Resolution’, Procedia Engineering, vol. 173, pp. 33–40, 2017 [Online]. Available: 10.1016/j.proeng.2016.12.016. [183] M. Hendriks, Identification of the mechanical behavior of solid materials, vol. 1, no. 1991. 1991 [Online]. Available: 10.6100/IR347994. [184] D. Claire et al., ‘A finite element formulation to identify damage fields: the equilibrium gap method’, International Journal for Numerical Methods in Engineering, vol. 61, no. 2, pp. 189–208, 2004 [Online]. Available: 10.1002/nme.1057. [185] B. Langrand et al., ‘Identification technique of constitutive model parameters for crashworthiness modelling’, Aerospace Science and Technology, vol. 3, no. 4, pp. 215–227, Jun. 1999 [Online]. Available: 10.1016/S1270-9638(99)80044-3. [186] A. Norouzi, Medical Image Segmentation Methods, Algorithms, and Applications. [Online]. Available: https://www.tandfonline.com/doi/epdf/10.1080/02564602.2014.906861?needAccess=true. [Accessed: 12 May 2024]. [187] P. Łuczkiewicz et al., ‘High meniscal slope angle as a risk factor for meniscal allograft extrusion’, Medical Hypotheses, vol. 101, pp. 48–51, Apr. 2017 [Online]. Available: 10.1016/J.MEHY.2017.02.003. [188] T. Liu et al., ‘The MRI-based 3D morphologic changes of knee meniscus under knee weight-bearing and early flexion conditions’, Scientific Reports, vol. 11, no. 1, Dec. 2021[Online]. Availablehttps://www.researchgate.net/publication/356149647_The_MRI-based_3D_morphologic_changes_of_knee_meniscus_under_knee_weight-bearing_and_early_flexion_conditions[Accessed: 11February2022]. [189] H. I. Inaba et al., ‘Influence of the Varus—Valgus Instability on the Contact of the Femoro-Tibial Joint’, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 204, no. 1, pp. 61–64, Mar. 1990 [Online]. Available: 10.1243/PIME_PROC_1990_204_229_02. [190] X. Lai et al., ‘LISA: Reasoning Segmentation via Large Language Model’. arXiv, Aug. 03, 2023[Online]. Availablehttp://arxiv.org/abs/2308.00692[Accessed: 18December2023]. [191] E. Peña et al., ‘Computer simulation of damage on distal femoral articular cartilage after meniscectomies’, Computers in Biology and Medicine, vol. 38, no. 1, pp. 69–81, Jan. 2008 [Online]. Available: 10.1016/j.compbiomed.2007.07.003. [192] T. L. Haut et al., ‘A high-accuracy three-dimensional coordinate digitizing system for reconstructing the geometry of diarthrodial joints’, Journal of Biomechanics, vol. 31, no. 6, pp. 571–577, Jun. 1998 [Online]. Available: 10.1016/S0021-9290(98)00049-9. [193] I. A. Anderson et al., ‘A novel method for measuring medial compartment pressures within the knee joint in-vivo’, Journal of Biomechanics, vol. 36, no. 9, pp. 1391–1395, Sep. 2003 [Online]. Available: 10.1016/S0021-9290(03)00158-1. [194] Part 4: Trends, NHS England Digital. [Online]. Available: https://digital.nhs.uk/data-and-information/publications/statistical/health-survey-for-england/2021/part-4-trends. [Accessed: 21 Feb. 2025]. [195] A. Saltelli et al., ‘Why so many published sensitivity analyses are false: A systematic review of sensitivity analysis practices’, Environmental Modelling & Software, vol. 114, pp. 29–39, Apr. 2019 [Online]. Available: 10.1016/J.ENVSOFT.2019.01.012. [196] A. Erdemir, ‘Open Knee: A Pathway to Community Driven Modeling and Simulation in Joint Biomechanics’, J Med Device, vol. 7, no. 4, p. 0409101, Dec. 2013 [Online]. Available: 10.1115/1.4025767. [197] R. J. Cooper et al., ‘The role of high-resolution cartilage thickness distribution for contact mechanics predictions in the tibiofemoral joint’, Proc Inst Mech Eng H, p. 09544119241307793, Jan. 2025 [Online]. Available: 10.1177/09544119241307793. [198] ABAQUS Analysis User’s Manual (v6.6)-Spring. [Online]. Available: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/usb/default.htm?startat=pt06ch26s01alm35.html. [Accessed: 14 May 2025]. [199] A. Liu et al., ‘Development of a specimen-specific in vitro pre-clinical simulation model of the human cadaveric knee with appropriate soft tissue constraints’, PLOS ONE, vol. 15, no. 10, p. e0238785, Oct. 2020 [Online]. Available: 10.1371/journal.pone.0238785. [200] ABAQUS/CAE User’s Manual (v6.6) - Steps. [Online]. Available: https://classes.engineering.wustl.edu/2009/spring/mase5513/abaqus/docs/v6.6/books/usi/default.htm?startat=pt03ch14s03s01.html. [Accessed: 04 Aug. 2023]. [201] K. E. Moglo and A. Shirazi-Adl, ‘Cruciate coupling and screw-home mechanism in passive knee joint during extension-flexion’, Journal of Biomechanics, vol. 38, no. 5, pp. 1075–1083, May 2005 [Online]. Available: 10.1016/j.jbiomech.2004.05.033. [202] T. L. H. Donahue et al., ‘A finite element model of the human knee joint for the study of tibio-femoral contact’, Journal of Biomechanical Engineering, vol. 124, no. 3, pp. 273–280, 2002 [Online]. Available: 10.1115/1.1470171. [203] M. Mengoni, ‘opti4Abq v 2.0.3’. Zenodo, Jun. 09, 2017[Online]. Availablehttps://zenodo.org/records/804934[Accessed: 4September2024]. [204] J. M. Peloquin et al., ‘Advances in Quantification of Meniscus Tensile Mechanics Including Nonlinearity, Yield, and Failure’, J Biomech Eng, vol. 138, no. 2, pp. 0210021–02100213, Feb. 2016 [Online]. Available: 10.1115/1.4032354. [205] Abaqus, (2023, ), Linear and nonlinear penalty contact enforcement method, Abaqus Analysis User’s Guide (6.13). [Online]. Available: http://130.149.89.49:2080/v6.13/books/usb/default.htm?startat=pt09ch38s01aus178.html. [206] P. Zellmann et al., ‘Finite Element Modelling Simulated Meniscus Translocation and Deformation during Locomotion of the Equine Stifle.’, Animals : an open access journal from MDPI, vol. 9, no. 8, Jul. 2019[Online]. Availablehttp://www.ncbi.nlm.nih.gov/pubmed/31370196[Accessed: 4July2020]. [207] D. Shriram et al., ‘Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis’, Scientific Reports 2017 7:1, vol. 7, no. 1, pp. 1–11, Jul. 2017 [Online]. Available: 10.1038/s41598-017-06271-3. [208] E. Peña et al., ‘A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint’, Journal of Biomechanics, vol. 39, no. 9, pp. 1686–1701, Jan. 2006 [Online]. Available: 10.1016/j.jbiomech.2005.04.030. [209] K.-J. Bathe, Finite Element Procedures Second Edition Bathe Finite Element Procedures Klaus-Jürgen Bathe Second Edition. 2006. [210] G. Pahl and W. Beitz, Engineering Design: A Systematic Approach. Springer Science & Business Media, 2013. [211] M. H. Gregory et al., ‘A Review of Translational Animal Models for Knee Osteoarthritis’, Arthritis, vol. 2012, no. 1, p. 764621, 2012 [Online]. Available: 10.1155/2012/764621. [212] R. McN. Alexander, ‘Bipedal animals, and their differences from humans’, Journal of Anatomy, vol. 204, no. 5, pp. 321–330, 2004 [Online]. Available: 10.1111/j.0021-8782.2004.00289.x. [213] J. Yao, ‘Mechanical Characterisation of Acetabular Soft Tissues : Experimental and Computational Study’, no. December, 2020. [214] Y. G. Koh et al., ‘Biomechanical influence of lateral meniscal allograft transplantation on knee joint mechanics during the gait cycle’, Journal of Orthopaedic Surgery and Research, vol. 14, no. 1, Sep. 2019 [Online]. Available: 10.1186/s13018-019-1347-y [Accessed: 4 July 2020]. [215] J. Schwer et al., ‘Degeneration Affects Three-Dimensional Strains in Human Menisci: In situ MRI Acquisition Combined With Image Registration’, Frontiers in Bioengineering and Biotechnology, vol. 8, no. September, pp. 1–12, 2020 [Online]. Available: 10.3389/fbioe.2020.582055. [216] National Institute for Health and Care Research (NIHR), Leeds Biomedical Research Centre. [Online]. Available: https://leedsbrc.nihr.ac.uk/. [Accessed: 14 Feb. 2025]. [217] Costs and payments, Parkside Private Patients Unit. [Online]. Available: https://www.somersetft.nhs.uk/parkside/?page_id=31&preview_id=31. [Accessed: 16 Feb. 2025]. [218] Siemens, ‘Magnetom Vida’, pp. 8–16, 2017. [219] D. Beyer et al., ‘Use of surface coils in magnetic resonance imaging of orbit and knee’, Diagn Imaging Clin Med, vol. 55, no. 1–2, pp. 84–91, 1986. [220] H. Wang et al., ‘An MRI-compatible loading device to assess knee joint cartilage deformation: Effect of preloading and inter-test repeatability’, Journal of Biomechanics, vol. 48, no. 12, pp. 2934–2940, Sep. 2015 [Online]. Available: 10.1016/j.jbiomech.2015.08.006. [221] Search for LeePTM Plastic Composite Springs | Lee Spring. [Online]. Available: https://www.leespring.com/compression-springs-leep. [Accessed: 21 Feb. 2025]. [222] G. A. Day, ‘The Effects of Vertebral Variation on the Mechanical Outcomes of Vertebroplasty’, no. December, 2018[Online]. Availablehttp://etheses.whiterose.ac.uk/23216/. [223] ‘simpleware-cad-datasheet-0322.pdf’. [Online]. Availablehttps://www.synopsys.com/content/dam/synopsys/simpleware/pdfs/simpleware-cad-datasheet-0322.pdf[Accessed: 3November2023]. [224] Z. Mohammadi and M. R. Keyvanpour, ‘Similarity Measures in Medical Image Registration A Review Article’, in 2021 12th International Conference on Information and Knowledge Technology (IKT), 2021, pp. 89–95[Online]. Availablehttps://ieeexplore.ieee.org/document/9685453[Accessed: 3November2023]. [225] Q. R. Razlighi et al., ‘Evaluating similarity measures for brain image registration’, Journal of Visual Communication and Image Representation, vol. 24, no. 7, pp. 977–987, Oct. 2013 [Online]. Available: 10.1016/j.jvcir.2013.06.010. [226] MultiStart - Find multiple local minima - MATLAB - MathWorks United Kingdom. [Online]. Available: https://uk.mathworks.com/help/gads/multistart.html. [Accessed: 13 Sep. 2024]. [227] R. Schaback and H. Wendland, ‘Kernel techniques: From machine learning to meshless methods’, Acta Numerica, vol. 15, pp. 543–639, May 2006 [Online]. Available: 10.1017/S0962492906270016. [228] A. Géron, Hands-on Machine Learning with Scikit-Learn, Keras, and TensorFlow: Concepts, Tools, and Techniques to Build Intelligent Systems. O’Reilly Media, Incorporated, 2019. [229] J. M. Párraga Quiroga et al., ‘Should a native depth-dependent distribution of human meniscus constitutive components be considered in FEA-models of the knee joint?’, Journal of the Mechanical Behavior of Biomedical Materials, vol. 38, pp. 242–250, Oct. 2014 [Online]. Available: 10.1016/j.jmbbm.2014.03.005. [230] F. Flandry and G. Hommel, ‘Normal Anatomy and Biomechanics of the Knee’, Sports Medicine and Arthroscopy Review, vol. 19, no. 2, p. 82, Jun. 2011 [Online]. Available: 10.1097/JSA.0b013e318210c0aa."],"dcterms:accessrights":["public"],"dc:title":["Quantifying knee meniscus tissue behaviour: A combined experimental and computational study"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000232232813"]},"updated_at":"2026-11-18T23:30:26Z"}