{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:37171"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:37171","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Image Reconstruction for Spinal Cord PET/MRI","abstract":"Despite some neurological conditions also affecting the spinal cord, research using PET/MRI has focused on brain imaging. Spinal cord MRI is common due to its high resolution and soft tissue contrast. PET, however, presents challenges due to its low resolution relative to the spinal cord’s diameter. In PET/MR, spinal cord PET may also be affected by incorrect attenuation correction due to a lack of vertebral bone in MR-derived attenuation maps. The impact of these effects and possible solutions were determined through a series of studies. A literature review established whether currently available physical phantoms were suitable for assessing the performance of PET/MR scanners. It was found that replicating tissue properties for both modalities within the same phantom was challenging, so typically one modality is prioritised. Phantom experiments were performed using a PET performance phantom and an anatomical ‘head and neck’ phantom to assess the performance of the SIGNA PET/MR Scanner. It was found that for features less than 20mm, the size and tracer uptake in these regions was underestimated in PET images. A simulation study is presented exploring the impact of MR-derived attenuation maps and PET detector resolution on measured tracer uptake in the spinal cord. This was compared to patient data. The results indicate that whilst tracer uptake is underestimated when vertebral bone is not accounted for in attenuation maps, partial volume effects due to PET detector resolution have the greatest impact. MR-guided reconstruction of PET data was investigated as a solution to resolving partial volume effects during PET image reconstruction, using MR images simultaneously acquired with PET data. Images reconstructed with MR-guided algorithms showed an increase in measured tracer uptake in the spinal cord compared to existing reconstruction algorithms. This suggests that MR-guided reconstruction of PET data can contribute to resolving partial volume effects.","abstract_html":"Despite some neurological conditions also affecting the spinal cord, research using PET/MRI has focused on brain imaging. Spinal cord MRI is common due to its high resolution and soft tissue contrast. PET, however, presents challenges due to its low resolution relative to the spinal cord’s diameter. In PET/MR, spinal cord PET may also be affected by incorrect attenuation correction due to a lack of vertebral bone in MR-derived attenuation maps. The impact of these effects and possible solutions were determined through a series of studies. A literature review established whether currently available physical phantoms were suitable for assessing the performance of PET/MR scanners. It was found that replicating tissue properties for both modalities within the same phantom was challenging, so typically one modality is prioritised. Phantom experiments were performed using a PET performance phantom and an anatomical ‘head and neck’ phantom to assess the performance of the SIGNA PET/MR Scanner. It was found that for features less than 20mm, the size and tracer uptake in these regions was underestimated in PET images. A simulation study is presented exploring the impact of MR-derived attenuation maps and PET detector resolution on measured tracer uptake in the spinal cord. This was compared to patient data. The results indicate that whilst tracer uptake is underestimated when vertebral bone is not accounted for in attenuation maps, partial volume effects due to PET detector resolution have the greatest impact. MR-guided reconstruction of PET data was investigated as a solution to resolving partial volume effects during PET image reconstruction, using MR images simultaneously acquired with PET data. Images reconstructed with MR-guided algorithms showed an increase in measured tracer uptake in the spinal cord compared to existing reconstruction algorithms. This suggests that MR-guided reconstruction of PET data can contribute to resolving partial volume effects.","abstract_has_math":false,"creators":["Lennie, Eve"],"institution":"University of Sheffield","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Sourbron, Steven","Tsoumpas, Charalampos","Hoggard, Nigel"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-06","date_published":"2025-06","updated_at":"2026-11-18T23:30:26Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["MR/R015902/1"],"render_values":[{"text":"MR/R015902/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000217711111"],"render_values":[{"text":"0000-0002-1771-1111","href":"https://orcid.org/0000-0002-1771-1111","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/37171/1/EveLennie_200184249_Thesis.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A37171","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sourbron, Steven","Tsoumpas, Charalampos","Hoggard, Nigel"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Medical Research Council"]},{"key":"dc:creator","label":"Author","values":["Lennie, Eve"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000217711111"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-06"]},{"key":"dc:date.issued","label":"Date","values":["2025-06"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Faculty of Health (Sheffield)","Medicine (Sheffield)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Sheffield"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/37171/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["MR/R015902/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/37171/1/EveLennie_200184249_Thesis.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Despite some neurological conditions also affecting the spinal cord, research using PET/MRI has focused on brain imaging. Spinal cord MRI is common due to its high resolution and soft tissue contrast. PET, however, presents challenges due to its low resolution relative to the spinal cord’s diameter. In PET/MR, spinal cord PET may also be affected by incorrect attenuation correction due to a lack of vertebral bone in MR-derived attenuation maps. The impact of these effects and possible solutions were determined through a series of studies. A literature review established whether currently available physical phantoms were suitable for assessing the performance of PET/MR scanners. It was found that replicating tissue properties for both modalities within the same phantom was challenging, so typically one modality is prioritised. Phantom experiments were performed using a PET performance phantom and an anatomical ‘head and neck’ phantom to assess the performance of the SIGNA PET/MR Scanner. It was found that for features less than 20mm, the size and tracer uptake in these regions was underestimated in PET images. A simulation study is presented exploring the impact of MR-derived attenuation maps and PET detector resolution on measured tracer uptake in the spinal cord. This was compared to patient data. The results indicate that whilst tracer uptake is underestimated when vertebral bone is not accounted for in attenuation maps, partial volume effects due to PET detector resolution have the greatest impact. MR-guided reconstruction of PET data was investigated as a solution to resolving partial volume effects during PET image reconstruction, using MR images simultaneously acquired with PET data. Images reconstructed with MR-guided algorithms showed an increase in measured tracer uptake in the spinal cord compared to existing reconstruction algorithms. This suggests that MR-guided reconstruction of PET data can contribute to resolving partial volume effects."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Image Reconstruction for Spinal Cord PET/MRI"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sourbron, Steven","Tsoumpas, Charalampos","Hoggard, Nigel"],"dc:contributor.sponsor":["Medical Research Council"],"dc:creator":["Lennie, Eve"],"dc:date":["2025-06"],"dc:date.issued":["2025-06"],"dc:description.abstract":["Despite some neurological conditions also affecting the spinal cord, research using PET/MRI has focused on brain imaging. Spinal cord MRI is common due to its high resolution and soft tissue contrast. PET, however, presents challenges due to its low resolution relative to the spinal cord’s diameter. In PET/MR, spinal cord PET may also be affected by incorrect attenuation correction due to a lack of vertebral bone in MR-derived attenuation maps. The impact of these effects and possible solutions were determined through a series of studies. A literature review established whether currently available physical phantoms were suitable for assessing the performance of PET/MR scanners. It was found that replicating tissue properties for both modalities within the same phantom was challenging, so typically one modality is prioritised. Phantom experiments were performed using a PET performance phantom and an anatomical ‘head and neck’ phantom to assess the performance of the SIGNA PET/MR Scanner. It was found that for features less than 20mm, the size and tracer uptake in these regions was underestimated in PET images. A simulation study is presented exploring the impact of MR-derived attenuation maps and PET detector resolution on measured tracer uptake in the spinal cord. This was compared to patient data. The results indicate that whilst tracer uptake is underestimated when vertebral bone is not accounted for in attenuation maps, partial volume effects due to PET detector resolution have the greatest impact. MR-guided reconstruction of PET data was investigated as a solution to resolving partial volume effects during PET image reconstruction, using MR images simultaneously acquired with PET data. Images reconstructed with MR-guided algorithms showed an increase in measured tracer uptake in the spinal cord compared to existing reconstruction algorithms. This suggests that MR-guided reconstruction of PET data can contribute to resolving partial volume effects."],"dc:format":["text"],"dc:identifier.grantnumber":["MR/R015902/1"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/37171/1/EveLennie_200184249_Thesis.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["Faculty of Health (Sheffield)","Medicine (Sheffield)"],"dc:publisher.institution":["University of Sheffield"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/37171/"],"dcterms:accessrights":["public"],"dc:title":["Image Reconstruction for Spinal Cord PET/MRI"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000217711111"]},"updated_at":"2026-11-18T23:30:26Z"}