{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:37300"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:37300","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Enhancing Magnetic Endoscope Manoeuvrability Using Tip-Growing and Developable Roller Mechanisms for Deep Navigation and Virtual Biopsies","abstract":"Early detection of gastrointestinal (GI) cancers significantly improves survival outcomes; however, current diagnostic pathways are limited by manual procedures that are time consuming, uncomfortable, and resource-intensive. In many health systems, especially those constrained by staff shortages or infrastructure, routine endoscopic screening remains inaccessible or inefficient. Colonoscopy, the gold standard for detecting colorectal cancer, is associated with discomfort, sedation requirements, and steep operator learning curves. The global push toward automation and patient-centric technologies has fueled interest in robotic solutions that can enhance the reach, dexterity, and diagnostic capability of endoscopic tools. This thesis is motivated by the clinical imperative to make GI cancer detection faster, safer, and more scalable using intelligent magnetically actuated robotic platforms. Chapter 2 introduces an oloid-shaped, magnetically actuated endoscope that restores rotational dexterity and achieves stable contact with the GI wall during 74% of rolling motion in vivo. Building on this, Chapter 3 integrates closed-loop magnetic control and high resolution micro-ultrasound imaging, enabling autonomous three-dimensional subsurface lesion detection and mapping, validated in benchtop and porcine in vivo models. Chapter 4 presents a tip-growing, magnetically steered \"vine robot\" endoscope with a minimum bending radius of 3.85 cm and stable, shear-free navigation, along with promising initial results for magnetic retraction to support deeper GI tract navigation. My work is situated at the intersection of magnetic actuation, soft robotics, and minimally invasive diagnostic techniques.","abstract_html":"Early detection of gastrointestinal (GI) cancers significantly improves survival outcomes; however, current diagnostic pathways are limited by manual procedures that are time consuming, uncomfortable, and resource-intensive. In many health systems, especially those constrained by staff shortages or infrastructure, routine endoscopic screening remains inaccessible or inefficient. Colonoscopy, the gold standard for detecting colorectal cancer, is associated with discomfort, sedation requirements, and steep operator learning curves. The global push toward automation and patient-centric technologies has fueled interest in robotic solutions that can enhance the reach, dexterity, and diagnostic capability of endoscopic tools. This thesis is motivated by the clinical imperative to make GI cancer detection faster, safer, and more scalable using intelligent magnetically actuated robotic platforms. Chapter 2 introduces an oloid-shaped, magnetically actuated endoscope that restores rotational dexterity and achieves stable contact with the GI wall during 74% of rolling motion in vivo. Building on this, Chapter 3 integrates closed-loop magnetic control and high resolution micro-ultrasound imaging, enabling autonomous three-dimensional subsurface lesion detection and mapping, validated in benchtop and porcine in vivo models. Chapter 4 presents a tip-growing, magnetically steered &quot;vine robot&quot; endoscope with a minimum bending radius of 3.85 cm and stable, shear-free navigation, along with promising initial results for magnetic retraction to support deeper GI tract navigation. My work is situated at the intersection of magnetic actuation, soft robotics, and minimally invasive diagnostic techniques.","abstract_has_math":false,"creators":["Greenidge, Nikita Jasmine"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Valdastri, Pietro","Chandler, James"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-06","date_published":"2025-06","updated_at":"2026-11-18T23:30:26Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/Y037235/1","EP/V047914/1","818045","952118","NIHR203331"],"render_values":[{"text":"EP/Y037235/1","href":null,"code":true},{"text":"EP/V047914/1","href":null,"code":true},{"text":"818045","href":null,"code":true},{"text":"952118","href":null,"code":true},{"text":"NIHR203331","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000304135503"],"render_values":[{"text":"0000-0003-0413-5503","href":"https://orcid.org/0000-0003-0413-5503","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/37300/1/PhDThesis_NJG_v4.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A37300","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Valdastri, Pietro","Chandler, James"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Engineering and Physical Sciences Research Council (EPSRC)","European Research Council (ERC)","European Commission (EC)","National Institute for Health and Care Research (NIHR)"]},{"key":"dc:creator","label":"Author","values":["Greenidge, Nikita Jasmine"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000304135503"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-06"]},{"key":"dc:date.issued","label":"Date","values":["2025-06"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Electronic & Electrical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/37300/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["Abbott, Jake J., Eric Diller, and Andrew J. Petruska (2020). “Magnetic Meth- ods in Robotics”. In: Annual Review of Control, Robotics, and Autonomous Systems 3.1. doi: 10/gj3ts6. url: https://doi.org/10.1146/annurev- control-081219-082713. Alagi, Hosam et al. (Apr. 2016). “A versatile and modular capacitive tactile proximity sensor”. In: 2016 IEEE Haptics Symposium (HAPTICS). doi: 10.1109/HAPTICS.2016.7463192. Anderson, Joseph C. et al. (Apr. 2007). “Colonoscopy in Women: Is It Still More Difficult Than Colonoscopy in Men and Is a Low BMI Still a Challenge?” English. In: Gastrointestinal Endoscopy 65.5. issn: 0016-5107, 1097-6779. doi: 10.1016/j.gie.2007.03.940. url: https://www.giejournal.org/ article/S0016-5107(07)01431-9/fulltext#relatedArticles. Andersson, Karin L. et al. (Mar. 2022). “Gender Differences in Colonoscopy: Im- plications for Clinical Practice and Female Gastroenterologists”. eng. In: Di- gestive Diseases and Sciences 67.3. issn: 1573-2568. doi: 10.1007/s10620- 021-07079-y. Barducci, Lavinia et al. (Sept. 2020). “Fundamentals of the gut for capsule engineers”. en. In: Progress in Biomedical Engineering 2.4. issn: 2516-1091. doi: 10/gk94hm. url: https://doi.org/10.1088/2516-1091/abab4c. Berthet-Rayne, Pierre et al. (July 2021). “MAMMOBOT: A Miniature Steerable Soft Growing Robot for Early Breast Cancer Detection”. In: IEEE Robotics and Automation Letters 6.3. issn: 2377-3766. doi: 10 . 1109 / LRA . 2021 . 3068676. url: https://ieeexplore.ieee.org/document/9387605. Bhatt, Asmeen, Prithvi Patil, and Nirav C. Thosani (July 2024). “Endoscopy ergonomics: a survey-based study exploring gender differences”. English. In: Gastrointestinal Endoscopy 100.1. issn: 0016-5107, 1097-6779. doi: 10. 1016/j.gie.2024.01.003. url: https://www.giejournal.org/article/ S0016-5107(24)00006-3/fulltext. Bianchi, Federico et al. (2022). “Hybrid 6-DoF Magnetic Localization for Robotic Capsule Endoscopes Compatible With High-Grade Magnetic Field Navigation”. In: IEEE Access 10. issn: 2169-3536. doi: 10.1109/ACCESS. 2021.3136796. url: https://ieeexplore.ieee.org/document/9656131/. Blumenschein, Laura H., Allison M. Okamura, and Elliot W. Hawkes (2017). “Modeling of Bioinspired Apical Extension in a Soft Robot”. en. In: Biomimetic and Biohybrid Systems. Ed. by Michael Mangan et al. Cham: Springer International Publishing. isbn: 978-3-319-63537-8. doi: 10.1007/ 978-3-319-63537-8_45. Bouakaz, Ayache and Jean Michel Escoffre (Mar. 2024). “From concept to early clinical trials: 30 years of microbubble-based ultrasound-mediated drug deliv- ery research”. en. In: Advanced Drug Delivery Reviews 206. issn: 0169409X. doi: 10 . 1016 / j . addr . 2024 . 115199. url: https : / / linkinghub . elsevier.com/retrieve/pii/S0169409X24000218. Bray, Freddie et al. (2024). “Global cancer statistics 2022: GLOBOCAN esti- mates of incidence and mortality worldwide for 36 cancers in 185 countries”. en. In: CA: A Cancer Journal for Clinicians 74.3. issn: 1542-4863. doi: 10.3322/caac.21834. url: https://onlinelibrary.wiley.com/doi/ abs/10.3322/caac.21834. Choi, Seongwook et al. (Mar. 2025). “Advancements in photoacoustic detection techniques for biomedical imaging”. en. In: npj Acoustics 1.1. Publisher: Nature Publishing Group. issn: 3005-141X. doi: 10 . 1038 / s44384 - 025 - 00005-w. url: https://www.nature.com/articles/s44384-025-00005-w (visited on 07/26/2025). Ciuti, Gastone et al. (May 2020). “Frontiers of Robotic Colonoscopy: A Compre- hensive Review of Robotic Colonoscopes and Technologies”. en. In: Journal of Clinical Medicine 9.6. issn: 2077-0383. doi: 10 / gm258h. url: https : //www.mdpi.com/2077-0383/9/6/1648. Coad, Margaret M. et al. (Apr. 2020a). “Retraction of Soft Growing Robots Without Buckling”. In: IEEE Robotics and Automation Letters 5.2. issn: 2377-3766. doi: 10.1109/LRA.2020.2970629. url: https://ieeexplore. ieee.org/document/8977330. Coad, Margaret M. et al. (Sept. 2020b). “Vine Robots”. In: IEEE Robotics & Automation Magazine 27.3. issn: 1558-223X. doi: 10 . 1109 / MRA . 2019 . 2947538. url: https://ieeexplore.ieee.org/document/8917931. Cosentino, Felice et al. (Aug. 2009). “Functional evaluation of the endotics sys- tem, a new disposable self-propelled robotic colonoscope: in vitro tests and clinical trial”. eng. In: The International Journal of Artificial Organs 32.8. issn: 0391-3988. doi: 10/gnnpq6. Cox, Benjamin F. et al. (May 2017). “Ultrasound capsule endoscopy: sounding out the future”. en. In: Annals of Translational Medicine 5.9. issn: 2305- 5847, 2305-5839. doi: 10 / gnj47g. url: https : / / atm . amegroups . com / article/view/14711. Cummins, Gerard et al. (July 2019). “Gastrointestinal diagnosis using non-white light imaging capsule endoscopy”. en. In: Nature Reviews Gastroenterology & Hepatology 16.7. issn: 1759-5053. doi: 10/gnj458. url: https://www. nature.com/articles/s41575-019-0140-z. Diller, Eric et al. (Jan. 2016). “Six-degree-of-freedom magnetic actuation for wireless microrobotics”. In: The International Journal of Robotics Research 35.1-3. issn: 0278-3649. doi: 10/f7642k. url: https://doi.org/10.1177/ 0278364915583539. Dirnbock, Hans and Hellmuth Stachel (Jan. 1997). “The Development of the Oloid”. In: Journal for Geometry and Graphics 1. Dreyfus, R. et al. (Feb. 2024). “Dexterous helical magnetic robot for improved endovascular access”. en. In: Science Robotics 9.87. issn: 2470-9476. doi: 10.1126/scirobotics.adh0298. url: https://www.science.org/doi/ 10.1126/scirobotics.adh0298. Erin, Onder et al. (Oct. 2024). “Strong magnetic actuation system with en- hanced field articulation through stacks of individually addressed coils”. en. In: Scientific Reports 14.1. issn: 2045-2322. doi: 10.1038/s41598- 024- 72615-5. url: https://www.nature.com/articles/s41598-024-72615- 5. ExactVu™ Micro-Ultrasound System - Exact Imaging. (N.d.). url: https:// www.exactimaging.com/exactvu-micro-ultrasound-system. Gall, T. M. H. et al. (Jan. 2014). “Mini-probe ultrasonography for the staging of colon cancer: a systematic review and meta-analysis”. eng. In: Colorectal Disease: The Official Journal of the Association of Coloproctology of Great Britain and Ireland 16.1. issn: 1463-1318. doi: 10.1111/codi.12445. Gervasoni, Simone et al. (Feb. 2022). “Magnetically Assisted Robotic Fetal Surgery for the Treatment of Spina Bifida”. In: IEEE Transactions on Med- ical Robotics and Bionics 4.1. issn: 2576-3202. doi: 10.1109/TMRB.2022. 3146351. url: https://ieeexplore.ieee.org/document/9702265. Giltinan, Joshua and Metin Sitti (Apr. 2019). “Simultaneous Six-Degree-of- Freedom Control of a Single-Body Magnetic Microrobot”. In: IEEE Robotics and Automation Letters 4.2. issn: 2377-3766. doi: 10 . 1109 / LRA . 2019 . 2891080. Gluck, Nathan et al. (May 2016). “A novel self-propelled disposable colonoscope is effective for colonoscopy in humans (with video)”. eng. In: Gastrointestinal Endoscopy 83.5. issn: 1097-6779. doi: 10/f8nzpt. Gora, Michalina J. et al. (Apr. 2017). “Endoscopic optical coherence tomogra- phy: technologies and clinical applications [Invited]”. In: Biomedical Optics Express 8.5. issn: 2156-7085. doi: 10.1364/BOE.8.002405. url: https: //www.ncbi.nlm.nih.gov/pmc/articles/PMC5480489/. Greenidge, Nikita J. et al. (Mar. 2025). “Harnessing the oloid shape in magnet- ically driven robots to enable high-resolution ultrasound imaging”. In: Sci- ence Robotics 10.100. doi: 10.1126/scirobotics.adq4198. url: https: //www.science.org/doi/10.1126/scirobotics.adq4198. Greer, Joseph D. et al. (May 2017). “Series pneumatic artificial muscles (sPAMs) and application to a soft continuum robot”. In: 2017 IEEE International Conference on Robotics and Automation (ICRA). doi: 10.1109/ICRA.2017. 7989648. url: https://ieeexplore.ieee.org/document/7989648. — (Feb. 2019). “A Soft, Steerable Continuum Robot That Grows via Tip Ex- tension”. en. In: Soft Robotics 6.1. issn: 2169-5172, 2169-5180. doi: 10 . 1089 / soro . 2018 . 0034. url: https : / / www . liebertpub . com / doi / 10 . 1089/soro.2018.0034. Haggerty, David A., Nicholas D. Naclerio, and Elliot W. Hawkes (July 2021). “Hybrid Vine Robot With Internal Steering-Reeling Mechanism Enhances System-Level Capabilities”. In: IEEE Robotics and Automation Letters 6.3. issn: 2377-3766. doi: 10 . 1109 / LRA . 2021 . 3072858. url: https : / / ieeexplore.ieee.org/document/9403886. Hawkes, Elliot W. et al. (July 2017). “A soft robot that navigates its en- vironment through growth”. In: Science Robotics 2.8. doi: 10 . 1126 / scirobotics.aan3028. url: https://www.science.org/doi/10.1126/ scirobotics.aan3028. Hazewinkel, Yark and Evelien Dekker (Oct. 2011). “Colonoscopy: basic princi- ples and novel techniques”. en. In: Nature Reviews Gastroenterology & Hep- atology 8.10. issn: 1759-5053. doi: 10 . 1038 / nrgastro . 2011 . 141. url: https://www.nature.com/articles/nrgastro.2011.141. Heap, William E. et al. (Sept. 2021). “Soft Retraction Device and Internal Camera Mount for Everting Vine Robots”. In: 2021 IEEE/RSJ Interna- tional Conference on Intelligent Robots and Systems (IROS). doi: 10 . 1109/IROS51168.2021.9636697. url: https://ieeexplore.ieee.org/ document/9636697. Hernot, Sophie and Alexander L. Klibanov (June 2008). “Microbubbles in ultrasound-triggered drug and gene delivery”. In: Advanced Drug Delivery Reviews. Ultrasound in Drug and Gene Delivery 60.10. issn: 0169-409X. doi: 10.1016/j.addr.2008.03.005. url: https://www.sciencedirect.com/ science/article/pii/S0169409X08000811. Hiroshi, Ira (2011). The Development of the Two-Circle-Roller in a Numerical Way. url: http://ilabo.bufsiz.jp/Development/2c-english.pdf. Hirschowitz, Basil I. (Apr. 2003). “Historical perspectives on technology in GI endoscopy”. In: Techniques in Gastrointestinal Endoscopy. Emerging Tech- nologies 5.2. issn: 1096-2883. doi: 10 . 1053 / tgie . 2003 . 1. url: https : //www.sciencedirect.com/science/article/pii/S1096288303800025. Huo, Yingxin et al. (2025). “Design, Control, and Clinical Applications of Mag- netic Actuation Systems: Challenges and Opportunities”. en. In: Advanced Intelligent Systems 7.3. issn: 2640-4567. doi: 10.1002/aisy.202400403. url: https : / / onlinelibrary . wiley . com / doi / abs / 10 . 1002 / aisy . 202400403. Iddan, Gavriel et al. (May 2000). “Wireless capsule endoscopy”. en. In: Nature 405.6785. issn: 1476-4687. doi: 10.1038/35013140. url: https://www. nature.com/articles/35013140. Jeon, Seungmun (May 2017). “A sphericon-shaped magnetic millirobot rolling on a surface actuated by an external wobbling magnetic field”. In: AIP Ad- vances 7. doi: 10/f99j7x. Jeong, Sang-Goo et al. (Oct. 2020). “A Tip Mount for Transporting Sen- sors and Tools using Soft Growing Robots”. In: 2020 IEEE/RSJ Inter- national Conference on Intelligent Robots and Systems (IROS). doi: 10 . 1109/IROS45743.2020.9340950. url: https://ieeexplore.ieee.org/ document/9340950. Kenters, N. et al. (Dec. 2018). “Worldwide practices on flexible endoscope re- processing”. en. In: Antimicrobial Resistance and Infection Control 7. doi: 10.1186/s13756- 018- 0446- 6. url: https://pmc.ncbi.nlm.nih.gov/ articles/PMC6296091/. Kim, Ji-hun et al. (July 2021). “Origami-inspired New Material Feeding Mech- anism for Soft Growing Robots to Keep the Camera Stay at the Tip by Securing its Path”. In: IEEE Robotics and Automation Letters 6.3. issn: 2377-3766. doi: 10.1109/LRA.2021.3068936. url: https://ieeexplore. ieee.org/document/9387161. Kim, Nam Gyun et al. (Sept. 2024a). “External Steering of Vine Robots via Magnetic Actuation”. In: Soft Robotics. issn: 2169-5172. doi: 10 . 1089 / soro.2023.0182. url: https://www.liebertpub.com/doi/abs/10.1089/ soro.2023.0182. Kim, Nam Gyun et al. (Feb. 2024b). “Self-Retractable Soft Growing Robots for Reliable and Fast Retraction While Preserving Their Inherent Advan- tages”. In: IEEE Robotics and Automation Letters 9.2. issn: 2377-3766. doi: 10 . 1109 / LRA . 2023 . 3341697. url: https : / / ieeexplore . ieee . org / document/10354368. Kim, Seung Han and Hoon Jai Chun (Oct. 2021). “Capsule Endoscopy: Pitfalls and Approaches to Overcome”. en. In: Diagnostics 11.10. issn: 2075-4418. doi: 10.3390/diagnostics11101765. url: https://www.mdpi.com/2075- 4418/11/10/1765. Kim, Yoonho et al. (Aug. 2019). “Ferromagnetic soft continuum robots”. In: Science Robotics 4.33. doi: 10.1126/scirobotics.aax7329. url: https: //www.science.org/doi/10.1126/scirobotics.aax7329. Kuleshov, Alexander S et al. (2011). “On the motion of the Oloid toy”. en. In: XXXIX International Summer School–Conference APM 2011. Kummer, Michael P. et al. (Dec. 2010). “OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation”. In: IEEE Transactions on Robotics 26.6. issn: 1941-0468. doi: 10 . 1109 / TRO . 2010 . 2073030. url: https : //ieeexplore.ieee.org/document/5595508. Larsen, Sara, Anthony Kalloo, and Susan Hutfless (Feb. 2020). “The hidden cost of colonoscopy including cost of reprocessing and infection rate: the implications for disposable colonoscopes”. en. In: Gut 69.2. issn: 0017-5749, 1468-3288. doi: 10/gm79vr. url: https://gut.bmj.com/content/69/2/ 197. Lay, Holly S. et al. (Apr. 2018). “Design and Simulation of a Ring-Shaped Lin- ear Array for Microultrasound Capsule Endoscopy”. In: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 65.4. issn: 1525-8955. doi: 10/gnj47b. Lee, Dong-Geol, Nam Gyun Kim, and Jee-Hwan Ryu (Oct. 2023). “High- Curvature Consecutive Tip Steering of a Soft Growing Robot for Improved Target Reachability”. In: 2023 IEEE/RSJ International Conference on In- telligent Robots and Systems (IROS). doi: 10 . 1109 / IROS55552 . 2023 . 10341407. url: https://ieeexplore.ieee.org/document/10341407. Lena, Chiara et al. (2024). “ENHANCED MONOCULAR DEPTH ESTIMA- TION FROM MOTION IN COLONOSCOPY”. en. In: Gastrointestinal En- doscopy. url: https://www.giejournal.org/article/S0016- 5107(24) 00901-5/fulltext. Li, Mingyuan et al. (May 2021). “VINE Catheter for Endovascular Surgery”. In: IEEE Transactions on Medical Robotics and Bionics 3.2. issn: 2576-3202. doi: 10.1109/TMRB.2021.3069984. url: https://ieeexplore.ieee.org/ document/9392018. Li, Yan et al. (Apr. 2019). “Multimodal endoscopy for colorectal cancer detection by optical coherence tomography and near-infrared fluorescence imaging”. In: Biomedical Optics Express 10.5. issn: 2156-7085. doi: 10.1364/BOE. 10 . 002419. url: https : / / www . ncbi . nlm . nih . gov / pmc / articles / PMC6524571/. Luong, Jamie et al. (Apr. 2019). “Eversion and Retraction of a Soft Robot Towards the Exploration of Coral Reefs”. In: 2019 2nd IEEE International Conference on Soft Robotics (RoboSoft). doi: 10 . 1109 / ROBOSOFT . 2019 . 8722730. url: https://ieeexplore.ieee.org/document/8722730. Mahoney, A. and J. J. Abbott (2014). “Generating Rotating Magnetic Fields With a Single Permanent Magnet for Propulsion of Untethered Magnetic Devices in a Lumen”. In: IEEE Transactions on Robotics. doi: 10/ghfgp6. Mahoney, Arthur W. and Jake J. Abbott (Jan. 2016). “Five-degree-of-freedom manipulation of an untethered magnetic device in fluid using a single per- manent magnet with application in stomach capsule endoscopy”. en. In: The International Journal of Robotics Research 35.1-3. issn: 0278-3649. doi: 10 . 1177 / 0278364914558006. url: https : / / doi . org / 10 . 1177 / 0278364914558006. Manfredi, Luigi et al. (July 2019). “A Soft Pneumatic Inchworm Double bal- loon (SPID) for colonoscopy”. en. In: Scientific Reports 9.1. issn: 2045-2322. doi: 10.1038/s41598- 019- 47320- 3. url: https://www.nature.com/ articles/s41598-019-47320-3. Martin, James W. et al. (Oct. 2020). “Enabling the future of colonoscopy with intelligent and autonomous magnetic manipulation”. en. In: Nature Machine Intelligence 2.10. issn: 2522-5839. doi: 10 / gm79tx. url: https : / / www . nature.com/articles/s42256-020-00231-9. Martin, James W. et al. (Aug. 2022). “Robotic Autonomy for Magnetic Endo- scope Biopsy”. In: IEEE Transactions on Medical Robotics and Bionics 4.3. issn: 2576-3202. doi: 10.1109/TMRB.2022.3187028. Mattille, Michelle et al. (2024). “Autonomous Magnetic Navigation in Endo- scopic Image Mosaics”. en. In: Advanced Science 11.19. issn: 2198-3844. doi: 10.1002/advs.202400980. url: https://onlinelibrary.wiley. com/doi/abs/10.1002/advs.202400980. Maur, Pascal Auf der et al. (Apr. 2021). “RoBoa: Construction and Evaluation of a Steerable Vine Robot for Search and Rescue Applications”. In: 2021 IEEE 4th International Conference on Soft Robotics (RoboSoft). doi: 10. 1109/RoboSoft51838.2021.9479192. url: https://ieeexplore.ieee. org/document/9479192. Mesot, Alexandre et al. (Aug. 2024). “Teleoperated Magnetic Endoscopy: A Case Study and Perspective”. en. In: Advanced Intelligent Systems. issn: 2640-4567, 2640-4567. doi: 10 . 1002 / aisy . 202400522. url: https : / / onlinelibrary.wiley.com/doi/10.1002/aisy.202400522. Mishima, Daisuke, Takeshi Aoki, and Shigeo Hirose (2006). “Development of Pneumatically Controlled Expandable Arm for Search in the Environment with Tight Access”. en. In: Field and Service Robotics: Recent Advances in Reserch and Applications. Ed. by Shin’ichi Yuta et al. Berlin, Heidelberg: Springer. isbn: 978-3-540-32854-4. doi: 10.1007/10991459_49. url: https: //doi.org/10.1007/10991459_49. Miyasaka, Muneaki and Peter Berkelman (Apr. 2014). “Magnetic levitation with unlimited omnidirectional rotation range”. In: Mechatronics 24. doi: 10 . 1016/j.mechatronics.2014.02.001. Moldovan, Alexandru C. et al. (Sept. 2023). “Power Consumption Consid- erations for Ultrasound Capsule Endoscopy”. In: 2023 IEEE Interna- tional Ultrasonics Symposium (IUS). Montreal, QC, Canada: IEEE. isbn: 9798350346459. doi: 10 . 1109 / IUS51837 . 2023 . 10306773. url: https : //ieeexplore.ieee.org/document/10306773/. Naclerio, Nicholas D. and Elliot W. Hawkes (Apr. 2020). “Simple, Low- Hysteresis, Foldable, Fabric Pneumatic Artificial Muscle”. In: IEEE Robotics and Automation Letters 5.2. issn: 2377-3766. doi: 10 . 1109 / LRA . 2020 . 2976309. url: https://ieeexplore.ieee.org/document/9013028. Naclerio, Nicholas D. et al. (June 2021). “Controlling subterranean forces en- ables a fast, steerable, burrowing soft robot”. In: Science Robotics 6.55. doi: 10.1126/scirobotics.abe2922. url: https://www.science.org/doi/ 10.1126/scirobotics.abe2922. Norton, Joseph C. et al. (June 2019). “Intelligent magnetic manipulation for gastrointestinal ultrasound”. In: Science Robotics 4.31. doi: 10 / gjpgdc. url: https://www.science.org/doi/10.1126/scirobotics.aav7725. Nouda, Sadaharu, Kazuhiro Ota, and Kazuhide Higuchi (2018). “Retrograde colon capsule endoscopy with the self-propelling capsule endoscope: The first human trial (with videos)”. en. In: Digestive Endoscopy 30.1. issn: 1443- 1661. doi: 10.1111/den.12969. url: https://onlinelibrary.wiley. com/doi/abs/10.1111/den.12969. Obstein, Keith et al. (June 2024). “The Magnetic Flexible Endoscope: Phase 1 First-In-Human Trial”. In: Gastrointestinal Endoscopy. 2024 DDW Abstract Issue 99.6, Supplement. issn: 0016-5107. doi: 10.1016/j.gie.2024.04. 2659. url: https://www.sciencedirect.com/science/article/pii/ S0016510724029183. Ofstead, Cori L. et al. (Feb. 2017). “Longitudinal assessment of reprocessing effectiveness for colonoscopes and gastroscopes: Results of visual inspections, biochemical markers, and microbial cultures”. eng. In: American Journal of Infection Control 45.2. issn: 1527-3296. doi: 10/f9x4sr. Petruska, Andrew and Jake Abbott (Feb. 2013). “Optimal Permanent-Magnet Geometries for Dipole Field Approximation”. In: Magnetics, IEEE Transac- tions on 49. doi: 10.1109/TMAG.2012.2205014. Petruska, Andrew J. (Oct. 2020). “Open-Loop Orientation Control Using Dy- namic Magnetic Fields”. en. In: IEEE Robotics and Automation Letters 5.4. issn: 2377-3766, 2377-3774. doi: 10.1109/LRA.2020.3009070. url: https: //ieeexplore.ieee.org/document/9140356/. Pittiglio, G. et al. (2022). “Collaborative magnetic manipulation via two roboti- cally actuated permanent magnets”. en. In: IEEE Transactions on Robotics. Published online. Pittiglio, Giovanni et al. (Apr. 2019). “Magnetic Levitation for Soft-Tethered Capsule Colonoscopy Actuated With a Single Permanent Magnet: A Dy- namic Control Approach”. In: IEEE Robotics and Automation Letters 4.2. issn: 2377-3766. doi: 10.1109/LRA.2019.2894907. Pittiglio, Giovanni et al. (July 2023). “Personalized magnetic tentacles for tar- geted photothermal cancer therapy in peripheral lungs”. en. In: Communica- tions Engineering 2.1. issn: 2731-3395. doi: 10.1038/s44172-023-00098-9. url: https://www.nature.com/articles/s44172-023-00098-9. Qiu, Yongqiang et al. (Mar. 2020). “Ultrasound Capsule Endoscopy With a Mechanically Scanning Micro-ultrasound: A Porcine Study”. English. In: Ultrasound in Medicine and Biology 46.3. issn: 0301-5629, 1879-291X. doi: 10.1016/j.ultrasmedbio.2019.12.003. url: https://www.umbjournal. org/article/S0301-5629(19)31623-0/fulltext. Reese, G. et al. (2008). Using terahertz pulsed imaging (TPI) to identify colonic pathology. English. IEEE. isbn: 978-1-4244-2119-0. doi: 10.1109/ICIMW. 2008 . 4665690. url: https : / / www . infona . pl / /resource / bwmeta1 . element.ieee-art-000004665690. Rey, Johannes Wilhelm, Ralf Kiesslich, and Arthur Hoffman (Aug. 2014). “New aspects of modern endoscopy”. In: World Journal of Gastrointestinal En- doscopy 6.8. issn: 1948-5190. doi: 10.4253/wjge.v6.i8.334. url: https: //www.ncbi.nlm.nih.gov/pmc/articles/PMC4133412/. Sato, Koichiro, Sumio Fujinuma, and Yoshihiro Sakai (2006). “Evaluation of the Looping Formation and Pain During Insertion into the Cecum in Colonoscopy”. en. In: Digestive Endoscopy 18.3. issn: 1443-1661. doi: 10. 1111/j.0915-5635.2006.00601.x. url: https://onlinelibrary.wiley. com/doi/abs/10.1111/j.0915-5635.2006.00601.x. Saunders, Brian P. et al. (Feb. 1996). “Why is colonoscopy more difficult in women?” English. In: Gastrointestinal Endoscopy 43.2. issn: 0016-5107, 1097-6779. doi: 10.1016/S0016- 5107(06)80113- 6. url: https://www. giejournal.org/article/S0016-5107(06)80113-6/fulltext. Seifert, Hans et al. (Aug. 2021). “Controversies in EUS: Do we need miniprobes?” In: Endoscopic Ultrasound 10.4. issn: 2303-9027. doi: 10 . 4103 / EUS - D - 20 - 00252. url: https : / / www . ncbi . nlm . nih . gov / pmc / articles/PMC8411553/. Shamsudhin, Naveen et al. (2017). “Magnetically guided capsule endoscopy”. en. In: Medical Physics 44.8. issn: 2473-4209. doi: 10/gmt4p2. url: https: //onlinelibrary.wiley.com/doi/abs/10.1002/mp.12299. Shekleton, Florence E. and Michael Okocha (2025). “UK Screening and Surveil- lance For Bowel Cancers”. eng. In: StatPearls. Treasure Island (FL): Stat- Pearls Publishing. url: http : / / www . ncbi . nlm . nih . gov / books / NBK599509/. Shergill, Amandeep K., Kenneth R. McQuaid, and David Rempel (July 2009). “Ergonomics and GI endoscopy”. en. In: Gastrointestinal Endoscopy 70.1. issn: 00165107. doi: 10 . 1016 / j . gie . 2008 . 12 . 235. url: https : / / linkinghub.elsevier.com/retrieve/pii/S0016510708032203. Simon, Karen (July 2016). “Colorectal cancer development and advances in screening”. In: Clinical Interventions in Aging 11. issn: 1176-9092. doi: 10 / gm78hd. url: https : / / www . ncbi . nlm . nih . gov / pmc / articles / PMC4958365/. Sliker, Levin J. and Gastone Ciuti (Nov. 2014). “Flexible and capsule endoscopy for screening, diagnosis and treatment”. eng. In: Expert Review of Medical Devices 11.6. issn: 1745-2422. doi: 10.1586/17434440.2014.941809. Sobolev, Yaroslav I. et al. (Aug. 2023). “Solid-body trajectoids shaped to roll along desired pathways”. en. In: Nature 620.7973. issn: 1476-4687. doi: 10. 1038/s41586-023-06306-y. url: https://www.nature.com/articles/ s41586-023-06306-y. Song, Li et al. (Oct. 2023). “Motion Control of Capsule Robot Based on Adap- tive Magnetic Levitation Using Electromagnetic Coil”. In: IEEE Transac- tions on Automation Science and Engineering 20.4. issn: 1558-3783. doi: 10 . 1109 / TASE . 2022 . 3201966. url: https : / / ieeexplore . ieee . org / document/9901490/?arnumber=9901490. Spada, Cristiano et al. (May 2024). “AI-assisted capsule endoscopy reading in suspected small bowel bleeding: a multicentre prospective study”. English. In: The Lancet Digital Health 6.5. issn: 2589-7500. doi: 10.1016/S2589- 7500(24)00048-7. url: https://www.thelancet.com/journals/landig/ article/PIIS2589-7500(24)00048-7/fulltext. Spier, Bret J. et al. (Feb. 2010). “Colonoscopy training in gastroenterology fellowships: determining competence”. eng. In: Gastrointestinal Endoscopy 71.2. issn: 1097-6779. doi: 10/d43r8s. Szabo, Thomas L. (Jan. 2004). “10 - Imaging Systems And Applications”. en. In: Diagnostic Ultrasound Imaging. Ed. by Thomas L. Szabo. Biomedical Engineering. Burlington: Academic Press. isbn: 978-0-12-680145-3. doi: 10. 1016/B978- 012680145- 3/50011- 6. url: https://www.sciencedirect. com/science/article/pii/B9780126801453500116. Taddese, Addisu Z et al. (July 2018). “Enhanced real-time pose estimation for closed-loop robotic manipulation of magnetically actuated capsule en- doscopes”. en. In: The International Journal of Robotics Research 37.8. issn: 0278-3649. doi: 10 / gd5k9x. url: https : / / doi . org / 10 . 1177 / 0278364918779132. Thornley, Colton R., Lan N. Pham, and Jake J. Abbott (July 2019). “Reconsid- ering Six-Degree-of-Freedom Magnetic Actuation Across Scales”. In: IEEE Robotics and Automation Letters 4.3. issn: 2377-3766. doi: 10.1109/LRA. 2019.2902742. Valdastri, Pietro, Massimiliano Simi, and Robert J. Webster (2012). “Advanced Technologies for Gastrointestinal Endoscopy”. In: Annual Review of Biomed- ical Engineering 14.1. doi: 10 . 1146 / annurev - bioeng - 071811 - 150006. url: https://doi.org/10.1146/annurev-bioeng-071811-150006. Van Wifferen, Francine et al. (June 2022). “Prioritisation of colonoscopy services in colorectal cancer screening programmes to minimise impact of COVID- 19 pandemic on predicted cancer burden: A comparative modelling study”. en. In: Journal of Medical Screening 29.2. issn: 0969-1413, 1475-5793. doi: 10 . 1177 / 09691413211056777. url: https : / / journals . sagepub . com / doi/10.1177/09691413211056777. Vassallo, Reid et al. (June 2023). “Robotically controlled three-dimensional micro-ultrasound for prostate biopsy guidance”. en. In: International Jour- nal of Computer Assisted Radiology and Surgery 18.6. issn: 1861-6429. doi: 10.1007/s11548-023-02869-3. url: https://doi.org/10.1007/s11548- 023-02869-3. Vucelic, Boris et al. (Mar. 2006). “The aer-o-scope: proof of concept of a pneu- matic, skill-independent, self-propelling, self-navigating colonoscope”. eng. In: Gastroenterology 130.3. 00137 ZSCC: 0000137. issn: 0016-5085. doi: 10/bvvctq. Wang, Heng et al. (Nov. 2023). “Three-degrees-of-freedom orientation manipu- lation of small untethered robots with a single anisotropic soft magnet”. en. In: Nature Communications 14.1. issn: 2041-1723. doi: 10.1038/s41467- 023- 42783- 5. url: https://www.nature.com/articles/s41467- 023- 42783-5. Wang, Pu et al. (Oct. 2020). “Lower Adenoma Miss Rate of Computer-Aided Detection-Assisted Colonoscopy vs Routine White-Light Colonoscopy in a Prospective Tandem Study”. English. In: Gastroenterology 159.4. issn: 0016- 5085, 1528-0012. doi: 10 . 1053 / j . gastro . 2020 . 06 . 023. url: https : //www.gastrojournal.org/article/S0016-5085(20)34820-4/fulltext. Wang, Xingying et al. (Sept. 2017). “Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy”. eng. In: IEEE transactions on medical imaging 36.9. issn: 1558- 254X. doi: 10/gmxdk5. Wilson, Ana and Brian P. Saunders (Sept. 2015). “Position change during colonoscopy: the oldest and best trick in the book”. English. In: Gastroin- testinal Endoscopy 82.3. issn: 0016-5107, 1097-6779. doi: 10.1016/j.gie. 2015 . 03 . 1987. url: https : / / www . giejournal . org / article / S0016 - 5107(15)02313-5/fulltext. Wintzer-Wehekind, L´eonard et al. (Mar. 2025). “Prospective assessment of learning curve and impact of intensive versus progressive training in colonoscopy competence among French residents”. In: BMC Medical Edu- cation 25.1. issn: 1472-6920. doi: 10.1186/s12909- 025- 06924- 2. url: https://doi.org/10.1186/s12909-025-06924-2. Xu, Changyu, Zilin Yang, and Guo Zhan Lum (May 2021). “Small-Scale Mag- netic Actuators with Optimal Six Degrees-of-Freedom”. In: Advanced Mate- rials 33.23. doi: 10.1002/adma.202100170. Yeung, Chung-Kwong, Jo LK Cheung, and Biji Sreedhar (2019). “Emerging next-generation robotic colonoscopy systems towards painless colonoscopy”. en. In: Journal of Digestive Diseases 20.4. issn: 1751-2980. doi: 10/gm78tw. Yoo, Su Woong et al. (Jan. 2018). “Endoscopic non-ablative fractional laser therapy in an orthotopic colon tumour model”. en. In: Scientific Reports 8.1. issn: 2045-2322. doi: 10.1038/s41598- 018- 19792- 2. url: https: //www.nature.com/articles/s41598-018-19792-2. Yue Xi and Pengfei Xu (2021). “Global colorectal cancer burden in 2020 and projections to 2040”. In: Translational Oncology. doi: 10.1016/j.tranon. 2021.101174. Yung, Diana E et al. (Oct. 2017). “Musculoskeletal injuries in gastrointestinal endoscopists: a systematic review”. In: Expert Review of Gastroenterology & Hepatology 11.10. issn: 1747-4124. doi: 10 / gm6dsj. url: https : / / doi . org/10.1080/17474124.2017.1356225"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/Y037235/1","EP/V047914/1","818045","952118","NIHR203331"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/37300/1/PhDThesis_NJG_v4.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Early detection of gastrointestinal (GI) cancers significantly improves survival outcomes; however, current diagnostic pathways are limited by manual procedures that are time consuming, uncomfortable, and resource-intensive. In many health systems, especially those constrained by staff shortages or infrastructure, routine endoscopic screening remains inaccessible or inefficient. Colonoscopy, the gold standard for detecting colorectal cancer, is associated with discomfort, sedation requirements, and steep operator learning curves. The global push toward automation and patient-centric technologies has fueled interest in robotic solutions that can enhance the reach, dexterity, and diagnostic capability of endoscopic tools. This thesis is motivated by the clinical imperative to make GI cancer detection faster, safer, and more scalable using intelligent magnetically actuated robotic platforms. Chapter 2 introduces an oloid-shaped, magnetically actuated endoscope that restores rotational dexterity and achieves stable contact with the GI wall during 74% of rolling motion in vivo. Building on this, Chapter 3 integrates closed-loop magnetic control and high resolution micro-ultrasound imaging, enabling autonomous three-dimensional subsurface lesion detection and mapping, validated in benchtop and porcine in vivo models. Chapter 4 presents a tip-growing, magnetically steered \"vine robot\" endoscope with a minimum bending radius of 3.85 cm and stable, shear-free navigation, along with promising initial results for magnetic retraction to support deeper GI tract navigation. My work is situated at the intersection of magnetic actuation, soft robotics, and minimally invasive diagnostic techniques."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Enhancing Magnetic Endoscope Manoeuvrability Using Tip-Growing and Developable Roller Mechanisms for Deep Navigation and Virtual Biopsies"]}]}],"canonical_facts":{"dc:contributor.advisor":["Valdastri, Pietro","Chandler, James"],"dc:contributor.sponsor":["Engineering and Physical Sciences Research Council (EPSRC)","European Research Council (ERC)","European Commission (EC)","National Institute for Health and Care Research (NIHR)"],"dc:creator":["Greenidge, Nikita Jasmine"],"dc:date":["2025-06"],"dc:date.issued":["2025-06"],"dc:description.abstract":["Early detection of gastrointestinal (GI) cancers significantly improves survival outcomes; however, current diagnostic pathways are limited by manual procedures that are time consuming, uncomfortable, and resource-intensive. In many health systems, especially those constrained by staff shortages or infrastructure, routine endoscopic screening remains inaccessible or inefficient. Colonoscopy, the gold standard for detecting colorectal cancer, is associated with discomfort, sedation requirements, and steep operator learning curves. The global push toward automation and patient-centric technologies has fueled interest in robotic solutions that can enhance the reach, dexterity, and diagnostic capability of endoscopic tools. This thesis is motivated by the clinical imperative to make GI cancer detection faster, safer, and more scalable using intelligent magnetically actuated robotic platforms. Chapter 2 introduces an oloid-shaped, magnetically actuated endoscope that restores rotational dexterity and achieves stable contact with the GI wall during 74% of rolling motion in vivo. Building on this, Chapter 3 integrates closed-loop magnetic control and high resolution micro-ultrasound imaging, enabling autonomous three-dimensional subsurface lesion detection and mapping, validated in benchtop and porcine in vivo models. Chapter 4 presents a tip-growing, magnetically steered \"vine robot\" endoscope with a minimum bending radius of 3.85 cm and stable, shear-free navigation, along with promising initial results for magnetic retraction to support deeper GI tract navigation. My work is situated at the intersection of magnetic actuation, soft robotics, and minimally invasive diagnostic techniques."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/Y037235/1","EP/V047914/1","818045","952118","NIHR203331"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/37300/1/PhDThesis_NJG_v4.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Electronic & Electrical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/37300/"],"dc:relation.references":["Abbott, Jake J., Eric Diller, and Andrew J. Petruska (2020). “Magnetic Meth- ods in Robotics”. In: Annual Review of Control, Robotics, and Autonomous Systems 3.1. doi: 10/gj3ts6. url: https://doi.org/10.1146/annurev- control-081219-082713. Alagi, Hosam et al. (Apr. 2016). “A versatile and modular capacitive tactile proximity sensor”. In: 2016 IEEE Haptics Symposium (HAPTICS). doi: 10.1109/HAPTICS.2016.7463192. Anderson, Joseph C. et al. (Apr. 2007). “Colonoscopy in Women: Is It Still More Difficult Than Colonoscopy in Men and Is a Low BMI Still a Challenge?” English. In: Gastrointestinal Endoscopy 65.5. issn: 0016-5107, 1097-6779. doi: 10.1016/j.gie.2007.03.940. url: https://www.giejournal.org/ article/S0016-5107(07)01431-9/fulltext#relatedArticles. Andersson, Karin L. et al. (Mar. 2022). “Gender Differences in Colonoscopy: Im- plications for Clinical Practice and Female Gastroenterologists”. eng. In: Di- gestive Diseases and Sciences 67.3. issn: 1573-2568. doi: 10.1007/s10620- 021-07079-y. Barducci, Lavinia et al. (Sept. 2020). “Fundamentals of the gut for capsule engineers”. en. In: Progress in Biomedical Engineering 2.4. issn: 2516-1091. doi: 10/gk94hm. url: https://doi.org/10.1088/2516-1091/abab4c. Berthet-Rayne, Pierre et al. (July 2021). “MAMMOBOT: A Miniature Steerable Soft Growing Robot for Early Breast Cancer Detection”. In: IEEE Robotics and Automation Letters 6.3. issn: 2377-3766. doi: 10 . 1109 / LRA . 2021 . 3068676. url: https://ieeexplore.ieee.org/document/9387605. Bhatt, Asmeen, Prithvi Patil, and Nirav C. Thosani (July 2024). “Endoscopy ergonomics: a survey-based study exploring gender differences”. English. In: Gastrointestinal Endoscopy 100.1. issn: 0016-5107, 1097-6779. doi: 10. 1016/j.gie.2024.01.003. url: https://www.giejournal.org/article/ S0016-5107(24)00006-3/fulltext. Bianchi, Federico et al. (2022). “Hybrid 6-DoF Magnetic Localization for Robotic Capsule Endoscopes Compatible With High-Grade Magnetic Field Navigation”. In: IEEE Access 10. issn: 2169-3536. doi: 10.1109/ACCESS. 2021.3136796. url: https://ieeexplore.ieee.org/document/9656131/. Blumenschein, Laura H., Allison M. Okamura, and Elliot W. Hawkes (2017). “Modeling of Bioinspired Apical Extension in a Soft Robot”. en. In: Biomimetic and Biohybrid Systems. Ed. by Michael Mangan et al. Cham: Springer International Publishing. isbn: 978-3-319-63537-8. doi: 10.1007/ 978-3-319-63537-8_45. Bouakaz, Ayache and Jean Michel Escoffre (Mar. 2024). “From concept to early clinical trials: 30 years of microbubble-based ultrasound-mediated drug deliv- ery research”. en. In: Advanced Drug Delivery Reviews 206. issn: 0169409X. doi: 10 . 1016 / j . addr . 2024 . 115199. url: https : / / linkinghub . elsevier.com/retrieve/pii/S0169409X24000218. Bray, Freddie et al. (2024). “Global cancer statistics 2022: GLOBOCAN esti- mates of incidence and mortality worldwide for 36 cancers in 185 countries”. en. In: CA: A Cancer Journal for Clinicians 74.3. issn: 1542-4863. doi: 10.3322/caac.21834. url: https://onlinelibrary.wiley.com/doi/ abs/10.3322/caac.21834. Choi, Seongwook et al. (Mar. 2025). “Advancements in photoacoustic detection techniques for biomedical imaging”. en. In: npj Acoustics 1.1. Publisher: Nature Publishing Group. issn: 3005-141X. doi: 10 . 1038 / s44384 - 025 - 00005-w. url: https://www.nature.com/articles/s44384-025-00005-w (visited on 07/26/2025). Ciuti, Gastone et al. (May 2020). “Frontiers of Robotic Colonoscopy: A Compre- hensive Review of Robotic Colonoscopes and Technologies”. en. In: Journal of Clinical Medicine 9.6. issn: 2077-0383. doi: 10 / gm258h. url: https : //www.mdpi.com/2077-0383/9/6/1648. Coad, Margaret M. et al. (Apr. 2020a). “Retraction of Soft Growing Robots Without Buckling”. In: IEEE Robotics and Automation Letters 5.2. issn: 2377-3766. doi: 10.1109/LRA.2020.2970629. url: https://ieeexplore. ieee.org/document/8977330. Coad, Margaret M. et al. (Sept. 2020b). “Vine Robots”. In: IEEE Robotics & Automation Magazine 27.3. issn: 1558-223X. doi: 10 . 1109 / MRA . 2019 . 2947538. url: https://ieeexplore.ieee.org/document/8917931. Cosentino, Felice et al. (Aug. 2009). “Functional evaluation of the endotics sys- tem, a new disposable self-propelled robotic colonoscope: in vitro tests and clinical trial”. eng. In: The International Journal of Artificial Organs 32.8. issn: 0391-3988. doi: 10/gnnpq6. Cox, Benjamin F. et al. (May 2017). “Ultrasound capsule endoscopy: sounding out the future”. en. In: Annals of Translational Medicine 5.9. issn: 2305- 5847, 2305-5839. doi: 10 / gnj47g. url: https : / / atm . amegroups . com / article/view/14711. Cummins, Gerard et al. (July 2019). “Gastrointestinal diagnosis using non-white light imaging capsule endoscopy”. en. In: Nature Reviews Gastroenterology & Hepatology 16.7. issn: 1759-5053. doi: 10/gnj458. url: https://www. nature.com/articles/s41575-019-0140-z. Diller, Eric et al. (Jan. 2016). “Six-degree-of-freedom magnetic actuation for wireless microrobotics”. In: The International Journal of Robotics Research 35.1-3. issn: 0278-3649. doi: 10/f7642k. url: https://doi.org/10.1177/ 0278364915583539. Dirnbock, Hans and Hellmuth Stachel (Jan. 1997). “The Development of the Oloid”. In: Journal for Geometry and Graphics 1. Dreyfus, R. et al. (Feb. 2024). “Dexterous helical magnetic robot for improved endovascular access”. en. In: Science Robotics 9.87. issn: 2470-9476. doi: 10.1126/scirobotics.adh0298. url: https://www.science.org/doi/ 10.1126/scirobotics.adh0298. Erin, Onder et al. (Oct. 2024). “Strong magnetic actuation system with en- hanced field articulation through stacks of individually addressed coils”. en. In: Scientific Reports 14.1. issn: 2045-2322. doi: 10.1038/s41598- 024- 72615-5. url: https://www.nature.com/articles/s41598-024-72615- 5. ExactVu™ Micro-Ultrasound System - Exact Imaging. (N.d.). url: https:// www.exactimaging.com/exactvu-micro-ultrasound-system. Gall, T. M. H. et al. (Jan. 2014). “Mini-probe ultrasonography for the staging of colon cancer: a systematic review and meta-analysis”. eng. In: Colorectal Disease: The Official Journal of the Association of Coloproctology of Great Britain and Ireland 16.1. issn: 1463-1318. doi: 10.1111/codi.12445. Gervasoni, Simone et al. (Feb. 2022). “Magnetically Assisted Robotic Fetal Surgery for the Treatment of Spina Bifida”. In: IEEE Transactions on Med- ical Robotics and Bionics 4.1. issn: 2576-3202. doi: 10.1109/TMRB.2022. 3146351. url: https://ieeexplore.ieee.org/document/9702265. Giltinan, Joshua and Metin Sitti (Apr. 2019). “Simultaneous Six-Degree-of- Freedom Control of a Single-Body Magnetic Microrobot”. In: IEEE Robotics and Automation Letters 4.2. issn: 2377-3766. doi: 10 . 1109 / LRA . 2019 . 2891080. Gluck, Nathan et al. (May 2016). “A novel self-propelled disposable colonoscope is effective for colonoscopy in humans (with video)”. eng. In: Gastrointestinal Endoscopy 83.5. issn: 1097-6779. doi: 10/f8nzpt. Gora, Michalina J. et al. (Apr. 2017). “Endoscopic optical coherence tomogra- phy: technologies and clinical applications [Invited]”. In: Biomedical Optics Express 8.5. issn: 2156-7085. doi: 10.1364/BOE.8.002405. url: https: //www.ncbi.nlm.nih.gov/pmc/articles/PMC5480489/. Greenidge, Nikita J. et al. (Mar. 2025). “Harnessing the oloid shape in magnet- ically driven robots to enable high-resolution ultrasound imaging”. In: Sci- ence Robotics 10.100. doi: 10.1126/scirobotics.adq4198. url: https: //www.science.org/doi/10.1126/scirobotics.adq4198. Greer, Joseph D. et al. (May 2017). “Series pneumatic artificial muscles (sPAMs) and application to a soft continuum robot”. In: 2017 IEEE International Conference on Robotics and Automation (ICRA). doi: 10.1109/ICRA.2017. 7989648. url: https://ieeexplore.ieee.org/document/7989648. — (Feb. 2019). “A Soft, Steerable Continuum Robot That Grows via Tip Ex- tension”. en. In: Soft Robotics 6.1. issn: 2169-5172, 2169-5180. doi: 10 . 1089 / soro . 2018 . 0034. url: https : / / www . liebertpub . com / doi / 10 . 1089/soro.2018.0034. Haggerty, David A., Nicholas D. Naclerio, and Elliot W. Hawkes (July 2021). “Hybrid Vine Robot With Internal Steering-Reeling Mechanism Enhances System-Level Capabilities”. In: IEEE Robotics and Automation Letters 6.3. issn: 2377-3766. doi: 10 . 1109 / LRA . 2021 . 3072858. url: https : / / ieeexplore.ieee.org/document/9403886. Hawkes, Elliot W. et al. (July 2017). “A soft robot that navigates its en- vironment through growth”. In: Science Robotics 2.8. doi: 10 . 1126 / scirobotics.aan3028. url: https://www.science.org/doi/10.1126/ scirobotics.aan3028. Hazewinkel, Yark and Evelien Dekker (Oct. 2011). “Colonoscopy: basic princi- ples and novel techniques”. en. In: Nature Reviews Gastroenterology & Hep- atology 8.10. issn: 1759-5053. doi: 10 . 1038 / nrgastro . 2011 . 141. url: https://www.nature.com/articles/nrgastro.2011.141. Heap, William E. et al. (Sept. 2021). “Soft Retraction Device and Internal Camera Mount for Everting Vine Robots”. In: 2021 IEEE/RSJ Interna- tional Conference on Intelligent Robots and Systems (IROS). doi: 10 . 1109/IROS51168.2021.9636697. url: https://ieeexplore.ieee.org/ document/9636697. Hernot, Sophie and Alexander L. Klibanov (June 2008). “Microbubbles in ultrasound-triggered drug and gene delivery”. In: Advanced Drug Delivery Reviews. Ultrasound in Drug and Gene Delivery 60.10. issn: 0169-409X. doi: 10.1016/j.addr.2008.03.005. url: https://www.sciencedirect.com/ science/article/pii/S0169409X08000811. Hiroshi, Ira (2011). The Development of the Two-Circle-Roller in a Numerical Way. url: http://ilabo.bufsiz.jp/Development/2c-english.pdf. Hirschowitz, Basil I. (Apr. 2003). “Historical perspectives on technology in GI endoscopy”. In: Techniques in Gastrointestinal Endoscopy. Emerging Tech- nologies 5.2. issn: 1096-2883. doi: 10 . 1053 / tgie . 2003 . 1. url: https : //www.sciencedirect.com/science/article/pii/S1096288303800025. Huo, Yingxin et al. (2025). “Design, Control, and Clinical Applications of Mag- netic Actuation Systems: Challenges and Opportunities”. en. In: Advanced Intelligent Systems 7.3. issn: 2640-4567. doi: 10.1002/aisy.202400403. url: https : / / onlinelibrary . wiley . com / doi / abs / 10 . 1002 / aisy . 202400403. Iddan, Gavriel et al. (May 2000). “Wireless capsule endoscopy”. en. In: Nature 405.6785. issn: 1476-4687. doi: 10.1038/35013140. url: https://www. nature.com/articles/35013140. Jeon, Seungmun (May 2017). “A sphericon-shaped magnetic millirobot rolling on a surface actuated by an external wobbling magnetic field”. In: AIP Ad- vances 7. doi: 10/f99j7x. Jeong, Sang-Goo et al. (Oct. 2020). “A Tip Mount for Transporting Sen- sors and Tools using Soft Growing Robots”. In: 2020 IEEE/RSJ Inter- national Conference on Intelligent Robots and Systems (IROS). doi: 10 . 1109/IROS45743.2020.9340950. url: https://ieeexplore.ieee.org/ document/9340950. Kenters, N. et al. (Dec. 2018). “Worldwide practices on flexible endoscope re- processing”. en. In: Antimicrobial Resistance and Infection Control 7. doi: 10.1186/s13756- 018- 0446- 6. url: https://pmc.ncbi.nlm.nih.gov/ articles/PMC6296091/. Kim, Ji-hun et al. (July 2021). “Origami-inspired New Material Feeding Mech- anism for Soft Growing Robots to Keep the Camera Stay at the Tip by Securing its Path”. In: IEEE Robotics and Automation Letters 6.3. issn: 2377-3766. doi: 10.1109/LRA.2021.3068936. url: https://ieeexplore. ieee.org/document/9387161. Kim, Nam Gyun et al. (Sept. 2024a). “External Steering of Vine Robots via Magnetic Actuation”. In: Soft Robotics. issn: 2169-5172. doi: 10 . 1089 / soro.2023.0182. url: https://www.liebertpub.com/doi/abs/10.1089/ soro.2023.0182. Kim, Nam Gyun et al. (Feb. 2024b). “Self-Retractable Soft Growing Robots for Reliable and Fast Retraction While Preserving Their Inherent Advan- tages”. In: IEEE Robotics and Automation Letters 9.2. issn: 2377-3766. doi: 10 . 1109 / LRA . 2023 . 3341697. url: https : / / ieeexplore . ieee . org / document/10354368. Kim, Seung Han and Hoon Jai Chun (Oct. 2021). “Capsule Endoscopy: Pitfalls and Approaches to Overcome”. en. In: Diagnostics 11.10. issn: 2075-4418. doi: 10.3390/diagnostics11101765. url: https://www.mdpi.com/2075- 4418/11/10/1765. Kim, Yoonho et al. (Aug. 2019). “Ferromagnetic soft continuum robots”. In: Science Robotics 4.33. doi: 10.1126/scirobotics.aax7329. url: https: //www.science.org/doi/10.1126/scirobotics.aax7329. Kuleshov, Alexander S et al. (2011). “On the motion of the Oloid toy”. en. In: XXXIX International Summer School–Conference APM 2011. Kummer, Michael P. et al. (Dec. 2010). “OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation”. In: IEEE Transactions on Robotics 26.6. issn: 1941-0468. doi: 10 . 1109 / TRO . 2010 . 2073030. url: https : //ieeexplore.ieee.org/document/5595508. Larsen, Sara, Anthony Kalloo, and Susan Hutfless (Feb. 2020). “The hidden cost of colonoscopy including cost of reprocessing and infection rate: the implications for disposable colonoscopes”. en. In: Gut 69.2. issn: 0017-5749, 1468-3288. doi: 10/gm79vr. url: https://gut.bmj.com/content/69/2/ 197. Lay, Holly S. et al. (Apr. 2018). “Design and Simulation of a Ring-Shaped Lin- ear Array for Microultrasound Capsule Endoscopy”. In: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 65.4. issn: 1525-8955. doi: 10/gnj47b. Lee, Dong-Geol, Nam Gyun Kim, and Jee-Hwan Ryu (Oct. 2023). “High- Curvature Consecutive Tip Steering of a Soft Growing Robot for Improved Target Reachability”. In: 2023 IEEE/RSJ International Conference on In- telligent Robots and Systems (IROS). doi: 10 . 1109 / IROS55552 . 2023 . 10341407. url: https://ieeexplore.ieee.org/document/10341407. Lena, Chiara et al. (2024). “ENHANCED MONOCULAR DEPTH ESTIMA- TION FROM MOTION IN COLONOSCOPY”. en. In: Gastrointestinal En- doscopy. url: https://www.giejournal.org/article/S0016- 5107(24) 00901-5/fulltext. Li, Mingyuan et al. (May 2021). “VINE Catheter for Endovascular Surgery”. In: IEEE Transactions on Medical Robotics and Bionics 3.2. issn: 2576-3202. doi: 10.1109/TMRB.2021.3069984. url: https://ieeexplore.ieee.org/ document/9392018. Li, Yan et al. (Apr. 2019). “Multimodal endoscopy for colorectal cancer detection by optical coherence tomography and near-infrared fluorescence imaging”. In: Biomedical Optics Express 10.5. issn: 2156-7085. doi: 10.1364/BOE. 10 . 002419. url: https : / / www . ncbi . nlm . nih . gov / pmc / articles / PMC6524571/. Luong, Jamie et al. (Apr. 2019). “Eversion and Retraction of a Soft Robot Towards the Exploration of Coral Reefs”. In: 2019 2nd IEEE International Conference on Soft Robotics (RoboSoft). doi: 10 . 1109 / ROBOSOFT . 2019 . 8722730. url: https://ieeexplore.ieee.org/document/8722730. Mahoney, A. and J. J. Abbott (2014). “Generating Rotating Magnetic Fields With a Single Permanent Magnet for Propulsion of Untethered Magnetic Devices in a Lumen”. In: IEEE Transactions on Robotics. doi: 10/ghfgp6. Mahoney, Arthur W. and Jake J. Abbott (Jan. 2016). “Five-degree-of-freedom manipulation of an untethered magnetic device in fluid using a single per- manent magnet with application in stomach capsule endoscopy”. en. In: The International Journal of Robotics Research 35.1-3. issn: 0278-3649. doi: 10 . 1177 / 0278364914558006. url: https : / / doi . org / 10 . 1177 / 0278364914558006. Manfredi, Luigi et al. (July 2019). “A Soft Pneumatic Inchworm Double bal- loon (SPID) for colonoscopy”. en. In: Scientific Reports 9.1. issn: 2045-2322. doi: 10.1038/s41598- 019- 47320- 3. url: https://www.nature.com/ articles/s41598-019-47320-3. Martin, James W. et al. (Oct. 2020). “Enabling the future of colonoscopy with intelligent and autonomous magnetic manipulation”. en. In: Nature Machine Intelligence 2.10. issn: 2522-5839. doi: 10 / gm79tx. url: https : / / www . nature.com/articles/s42256-020-00231-9. Martin, James W. et al. (Aug. 2022). “Robotic Autonomy for Magnetic Endo- scope Biopsy”. In: IEEE Transactions on Medical Robotics and Bionics 4.3. issn: 2576-3202. doi: 10.1109/TMRB.2022.3187028. Mattille, Michelle et al. (2024). “Autonomous Magnetic Navigation in Endo- scopic Image Mosaics”. en. In: Advanced Science 11.19. issn: 2198-3844. doi: 10.1002/advs.202400980. url: https://onlinelibrary.wiley. com/doi/abs/10.1002/advs.202400980. Maur, Pascal Auf der et al. (Apr. 2021). “RoBoa: Construction and Evaluation of a Steerable Vine Robot for Search and Rescue Applications”. In: 2021 IEEE 4th International Conference on Soft Robotics (RoboSoft). doi: 10. 1109/RoboSoft51838.2021.9479192. url: https://ieeexplore.ieee. org/document/9479192. Mesot, Alexandre et al. (Aug. 2024). “Teleoperated Magnetic Endoscopy: A Case Study and Perspective”. en. In: Advanced Intelligent Systems. issn: 2640-4567, 2640-4567. doi: 10 . 1002 / aisy . 202400522. url: https : / / onlinelibrary.wiley.com/doi/10.1002/aisy.202400522. Mishima, Daisuke, Takeshi Aoki, and Shigeo Hirose (2006). “Development of Pneumatically Controlled Expandable Arm for Search in the Environment with Tight Access”. en. In: Field and Service Robotics: Recent Advances in Reserch and Applications. Ed. by Shin’ichi Yuta et al. Berlin, Heidelberg: Springer. isbn: 978-3-540-32854-4. doi: 10.1007/10991459_49. url: https: //doi.org/10.1007/10991459_49. Miyasaka, Muneaki and Peter Berkelman (Apr. 2014). “Magnetic levitation with unlimited omnidirectional rotation range”. In: Mechatronics 24. doi: 10 . 1016/j.mechatronics.2014.02.001. Moldovan, Alexandru C. et al. (Sept. 2023). “Power Consumption Consid- erations for Ultrasound Capsule Endoscopy”. In: 2023 IEEE Interna- tional Ultrasonics Symposium (IUS). Montreal, QC, Canada: IEEE. isbn: 9798350346459. doi: 10 . 1109 / IUS51837 . 2023 . 10306773. url: https : //ieeexplore.ieee.org/document/10306773/. Naclerio, Nicholas D. and Elliot W. Hawkes (Apr. 2020). “Simple, Low- Hysteresis, Foldable, Fabric Pneumatic Artificial Muscle”. In: IEEE Robotics and Automation Letters 5.2. issn: 2377-3766. doi: 10 . 1109 / LRA . 2020 . 2976309. url: https://ieeexplore.ieee.org/document/9013028. Naclerio, Nicholas D. et al. (June 2021). “Controlling subterranean forces en- ables a fast, steerable, burrowing soft robot”. In: Science Robotics 6.55. doi: 10.1126/scirobotics.abe2922. url: https://www.science.org/doi/ 10.1126/scirobotics.abe2922. Norton, Joseph C. et al. (June 2019). “Intelligent magnetic manipulation for gastrointestinal ultrasound”. In: Science Robotics 4.31. doi: 10 / gjpgdc. url: https://www.science.org/doi/10.1126/scirobotics.aav7725. Nouda, Sadaharu, Kazuhiro Ota, and Kazuhide Higuchi (2018). “Retrograde colon capsule endoscopy with the self-propelling capsule endoscope: The first human trial (with videos)”. en. In: Digestive Endoscopy 30.1. issn: 1443- 1661. doi: 10.1111/den.12969. url: https://onlinelibrary.wiley. com/doi/abs/10.1111/den.12969. Obstein, Keith et al. (June 2024). “The Magnetic Flexible Endoscope: Phase 1 First-In-Human Trial”. In: Gastrointestinal Endoscopy. 2024 DDW Abstract Issue 99.6, Supplement. issn: 0016-5107. doi: 10.1016/j.gie.2024.04. 2659. url: https://www.sciencedirect.com/science/article/pii/ S0016510724029183. Ofstead, Cori L. et al. (Feb. 2017). “Longitudinal assessment of reprocessing effectiveness for colonoscopes and gastroscopes: Results of visual inspections, biochemical markers, and microbial cultures”. eng. In: American Journal of Infection Control 45.2. issn: 1527-3296. doi: 10/f9x4sr. Petruska, Andrew and Jake Abbott (Feb. 2013). “Optimal Permanent-Magnet Geometries for Dipole Field Approximation”. In: Magnetics, IEEE Transac- tions on 49. doi: 10.1109/TMAG.2012.2205014. Petruska, Andrew J. (Oct. 2020). “Open-Loop Orientation Control Using Dy- namic Magnetic Fields”. en. In: IEEE Robotics and Automation Letters 5.4. issn: 2377-3766, 2377-3774. doi: 10.1109/LRA.2020.3009070. url: https: //ieeexplore.ieee.org/document/9140356/. Pittiglio, G. et al. (2022). “Collaborative magnetic manipulation via two roboti- cally actuated permanent magnets”. en. In: IEEE Transactions on Robotics. Published online. Pittiglio, Giovanni et al. (Apr. 2019). “Magnetic Levitation for Soft-Tethered Capsule Colonoscopy Actuated With a Single Permanent Magnet: A Dy- namic Control Approach”. In: IEEE Robotics and Automation Letters 4.2. issn: 2377-3766. doi: 10.1109/LRA.2019.2894907. Pittiglio, Giovanni et al. (July 2023). “Personalized magnetic tentacles for tar- geted photothermal cancer therapy in peripheral lungs”. en. In: Communica- tions Engineering 2.1. issn: 2731-3395. doi: 10.1038/s44172-023-00098-9. url: https://www.nature.com/articles/s44172-023-00098-9. Qiu, Yongqiang et al. (Mar. 2020). “Ultrasound Capsule Endoscopy With a Mechanically Scanning Micro-ultrasound: A Porcine Study”. English. In: Ultrasound in Medicine and Biology 46.3. issn: 0301-5629, 1879-291X. doi: 10.1016/j.ultrasmedbio.2019.12.003. url: https://www.umbjournal. org/article/S0301-5629(19)31623-0/fulltext. Reese, G. et al. (2008). Using terahertz pulsed imaging (TPI) to identify colonic pathology. English. IEEE. isbn: 978-1-4244-2119-0. doi: 10.1109/ICIMW. 2008 . 4665690. url: https : / / www . infona . pl / /resource / bwmeta1 . element.ieee-art-000004665690. Rey, Johannes Wilhelm, Ralf Kiesslich, and Arthur Hoffman (Aug. 2014). “New aspects of modern endoscopy”. In: World Journal of Gastrointestinal En- doscopy 6.8. issn: 1948-5190. doi: 10.4253/wjge.v6.i8.334. url: https: //www.ncbi.nlm.nih.gov/pmc/articles/PMC4133412/. Sato, Koichiro, Sumio Fujinuma, and Yoshihiro Sakai (2006). “Evaluation of the Looping Formation and Pain During Insertion into the Cecum in Colonoscopy”. en. In: Digestive Endoscopy 18.3. issn: 1443-1661. doi: 10. 1111/j.0915-5635.2006.00601.x. url: https://onlinelibrary.wiley. com/doi/abs/10.1111/j.0915-5635.2006.00601.x. Saunders, Brian P. et al. (Feb. 1996). “Why is colonoscopy more difficult in women?” English. In: Gastrointestinal Endoscopy 43.2. issn: 0016-5107, 1097-6779. doi: 10.1016/S0016- 5107(06)80113- 6. url: https://www. giejournal.org/article/S0016-5107(06)80113-6/fulltext. Seifert, Hans et al. (Aug. 2021). “Controversies in EUS: Do we need miniprobes?” In: Endoscopic Ultrasound 10.4. issn: 2303-9027. doi: 10 . 4103 / EUS - D - 20 - 00252. url: https : / / www . ncbi . nlm . nih . gov / pmc / articles/PMC8411553/. Shamsudhin, Naveen et al. (2017). “Magnetically guided capsule endoscopy”. en. In: Medical Physics 44.8. issn: 2473-4209. doi: 10/gmt4p2. url: https: //onlinelibrary.wiley.com/doi/abs/10.1002/mp.12299. Shekleton, Florence E. and Michael Okocha (2025). “UK Screening and Surveil- lance For Bowel Cancers”. eng. In: StatPearls. Treasure Island (FL): Stat- Pearls Publishing. url: http : / / www . ncbi . nlm . nih . gov / books / NBK599509/. Shergill, Amandeep K., Kenneth R. McQuaid, and David Rempel (July 2009). “Ergonomics and GI endoscopy”. en. In: Gastrointestinal Endoscopy 70.1. issn: 00165107. doi: 10 . 1016 / j . gie . 2008 . 12 . 235. url: https : / / linkinghub.elsevier.com/retrieve/pii/S0016510708032203. Simon, Karen (July 2016). “Colorectal cancer development and advances in screening”. In: Clinical Interventions in Aging 11. issn: 1176-9092. doi: 10 / gm78hd. url: https : / / www . ncbi . nlm . nih . gov / pmc / articles / PMC4958365/. Sliker, Levin J. and Gastone Ciuti (Nov. 2014). “Flexible and capsule endoscopy for screening, diagnosis and treatment”. eng. In: Expert Review of Medical Devices 11.6. issn: 1745-2422. doi: 10.1586/17434440.2014.941809. Sobolev, Yaroslav I. et al. (Aug. 2023). “Solid-body trajectoids shaped to roll along desired pathways”. en. In: Nature 620.7973. issn: 1476-4687. doi: 10. 1038/s41586-023-06306-y. url: https://www.nature.com/articles/ s41586-023-06306-y. Song, Li et al. (Oct. 2023). “Motion Control of Capsule Robot Based on Adap- tive Magnetic Levitation Using Electromagnetic Coil”. In: IEEE Transac- tions on Automation Science and Engineering 20.4. issn: 1558-3783. doi: 10 . 1109 / TASE . 2022 . 3201966. url: https : / / ieeexplore . ieee . org / document/9901490/?arnumber=9901490. Spada, Cristiano et al. (May 2024). “AI-assisted capsule endoscopy reading in suspected small bowel bleeding: a multicentre prospective study”. English. In: The Lancet Digital Health 6.5. issn: 2589-7500. doi: 10.1016/S2589- 7500(24)00048-7. url: https://www.thelancet.com/journals/landig/ article/PIIS2589-7500(24)00048-7/fulltext. Spier, Bret J. et al. (Feb. 2010). “Colonoscopy training in gastroenterology fellowships: determining competence”. eng. In: Gastrointestinal Endoscopy 71.2. issn: 1097-6779. doi: 10/d43r8s. Szabo, Thomas L. (Jan. 2004). “10 - Imaging Systems And Applications”. en. In: Diagnostic Ultrasound Imaging. Ed. by Thomas L. Szabo. Biomedical Engineering. Burlington: Academic Press. isbn: 978-0-12-680145-3. doi: 10. 1016/B978- 012680145- 3/50011- 6. url: https://www.sciencedirect. com/science/article/pii/B9780126801453500116. Taddese, Addisu Z et al. (July 2018). “Enhanced real-time pose estimation for closed-loop robotic manipulation of magnetically actuated capsule en- doscopes”. en. In: The International Journal of Robotics Research 37.8. issn: 0278-3649. doi: 10 / gd5k9x. url: https : / / doi . org / 10 . 1177 / 0278364918779132. Thornley, Colton R., Lan N. Pham, and Jake J. Abbott (July 2019). “Reconsid- ering Six-Degree-of-Freedom Magnetic Actuation Across Scales”. In: IEEE Robotics and Automation Letters 4.3. issn: 2377-3766. doi: 10.1109/LRA. 2019.2902742. Valdastri, Pietro, Massimiliano Simi, and Robert J. Webster (2012). “Advanced Technologies for Gastrointestinal Endoscopy”. In: Annual Review of Biomed- ical Engineering 14.1. doi: 10 . 1146 / annurev - bioeng - 071811 - 150006. url: https://doi.org/10.1146/annurev-bioeng-071811-150006. Van Wifferen, Francine et al. (June 2022). “Prioritisation of colonoscopy services in colorectal cancer screening programmes to minimise impact of COVID- 19 pandemic on predicted cancer burden: A comparative modelling study”. en. In: Journal of Medical Screening 29.2. issn: 0969-1413, 1475-5793. doi: 10 . 1177 / 09691413211056777. url: https : / / journals . sagepub . com / doi/10.1177/09691413211056777. Vassallo, Reid et al. (June 2023). “Robotically controlled three-dimensional micro-ultrasound for prostate biopsy guidance”. en. In: International Jour- nal of Computer Assisted Radiology and Surgery 18.6. issn: 1861-6429. doi: 10.1007/s11548-023-02869-3. url: https://doi.org/10.1007/s11548- 023-02869-3. Vucelic, Boris et al. (Mar. 2006). “The aer-o-scope: proof of concept of a pneu- matic, skill-independent, self-propelling, self-navigating colonoscope”. eng. In: Gastroenterology 130.3. 00137 ZSCC: 0000137. issn: 0016-5085. doi: 10/bvvctq. Wang, Heng et al. (Nov. 2023). “Three-degrees-of-freedom orientation manipu- lation of small untethered robots with a single anisotropic soft magnet”. en. In: Nature Communications 14.1. issn: 2041-1723. doi: 10.1038/s41467- 023- 42783- 5. url: https://www.nature.com/articles/s41467- 023- 42783-5. Wang, Pu et al. (Oct. 2020). “Lower Adenoma Miss Rate of Computer-Aided Detection-Assisted Colonoscopy vs Routine White-Light Colonoscopy in a Prospective Tandem Study”. English. In: Gastroenterology 159.4. issn: 0016- 5085, 1528-0012. doi: 10 . 1053 / j . gastro . 2020 . 06 . 023. url: https : //www.gastrojournal.org/article/S0016-5085(20)34820-4/fulltext. Wang, Xingying et al. (Sept. 2017). “Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy”. eng. In: IEEE transactions on medical imaging 36.9. issn: 1558- 254X. doi: 10/gmxdk5. Wilson, Ana and Brian P. Saunders (Sept. 2015). “Position change during colonoscopy: the oldest and best trick in the book”. English. In: Gastroin- testinal Endoscopy 82.3. issn: 0016-5107, 1097-6779. doi: 10.1016/j.gie. 2015 . 03 . 1987. url: https : / / www . giejournal . org / article / S0016 - 5107(15)02313-5/fulltext. Wintzer-Wehekind, L´eonard et al. (Mar. 2025). “Prospective assessment of learning curve and impact of intensive versus progressive training in colonoscopy competence among French residents”. In: BMC Medical Edu- cation 25.1. issn: 1472-6920. doi: 10.1186/s12909- 025- 06924- 2. url: https://doi.org/10.1186/s12909-025-06924-2. Xu, Changyu, Zilin Yang, and Guo Zhan Lum (May 2021). “Small-Scale Mag- netic Actuators with Optimal Six Degrees-of-Freedom”. In: Advanced Mate- rials 33.23. doi: 10.1002/adma.202100170. Yeung, Chung-Kwong, Jo LK Cheung, and Biji Sreedhar (2019). “Emerging next-generation robotic colonoscopy systems towards painless colonoscopy”. en. In: Journal of Digestive Diseases 20.4. issn: 1751-2980. doi: 10/gm78tw. Yoo, Su Woong et al. (Jan. 2018). “Endoscopic non-ablative fractional laser therapy in an orthotopic colon tumour model”. en. In: Scientific Reports 8.1. issn: 2045-2322. doi: 10.1038/s41598- 018- 19792- 2. url: https: //www.nature.com/articles/s41598-018-19792-2. Yue Xi and Pengfei Xu (2021). “Global colorectal cancer burden in 2020 and projections to 2040”. In: Translational Oncology. doi: 10.1016/j.tranon. 2021.101174. Yung, Diana E et al. (Oct. 2017). “Musculoskeletal injuries in gastrointestinal endoscopists: a systematic review”. In: Expert Review of Gastroenterology & Hepatology 11.10. issn: 1747-4124. doi: 10 / gm6dsj. url: https : / / doi . org/10.1080/17474124.2017.1356225"],"dcterms:accessrights":["public"],"dc:title":["Enhancing Magnetic Endoscope Manoeuvrability Using Tip-Growing and Developable Roller Mechanisms for Deep Navigation and Virtual Biopsies"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"],"person:identifier.orcid":["0000000304135503"]},"updated_at":"2026-11-18T23:30:26Z"}