{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:39341"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:39341","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Can a Biomimetic Ankle Joint with Proprioception Provide Feedback On Its Operating Environment?","abstract":"In current prosthetic devices permitting rotation, one-degree-of-freedom pin-joint-based ankle joints are primarily used, while two-degree-of-freedom devices remain in research; however, it has been shown that they improve the balance of the user compared to one degree of freedom. These research-based devices also predominantly make use of pin joints, which are inherently less kinematically accurate than rolling contact joints of the human anatomy. A two-degree-of-freedom rolling contact joint is multiplanar, and, therefore, rigid links to constrain the joint cannot be used, as this could only operate in one plane. Using soft multiplanar links analogous to ligaments would not only constrain the joint but also allow for characterisation of the joints by measuring the displacement of the links, which can be used to estimate joint angle for traditional control. A simplified version of the tibiotalar and subtalar joints of the ankle was made, forming a joint complex capable of motion in the coronal and sagittal planes. Silicone links were produced with a silicone-based infrared waveguide embedded to provide proprioception of the joint. The anterior talofibular, calcaneofibular, tibiocalcaneal, and superficial tibiotalar ligaments of the ankle were manufactured as deformable waveguides and tested at 10+% strain to verify linearity. The R2 value of all the ligaments when compared with a linear regression model was above 0.996 between the operating range of 0-6% strain. Then the joint complex as a whole was manipulated in the sagittal and coronal planes, providing evidence that there were unique behaviours in the ligament stretch demonstrated in each discrete plantar position, dorsiflexion, plantarflexion, inversion, and eversion. This could then be used in a control scheme for the joint to identify the planar position of the joint, which could then be used to drive and sense two planes of a prosthetic foot. This would ultimately improve balance and stability by permitting the foot to adapt to the floor in both planes with anatomical-like compliance, while allowing for the prediction of the geometry for a control scheme with active control for balance and stability.","abstract_html":"In current prosthetic devices permitting rotation, one-degree-of-freedom pin-joint-based ankle joints are primarily used, while two-degree-of-freedom devices remain in research; however, it has been shown that they improve the balance of the user compared to one degree of freedom. These research-based devices also predominantly make use of pin joints, which are inherently less kinematically accurate than rolling contact joints of the human anatomy. A two-degree-of-freedom rolling contact joint is multiplanar, and, therefore, rigid links to constrain the joint cannot be used, as this could only operate in one plane. Using soft multiplanar links analogous to ligaments would not only constrain the joint but also allow for characterisation of the joints by measuring the displacement of the links, which can be used to estimate joint angle for traditional control. A simplified version of the tibiotalar and subtalar joints of the ankle was made, forming a joint complex capable of motion in the coronal and sagittal planes. Silicone links were produced with a silicone-based infrared waveguide embedded to provide proprioception of the joint. The anterior talofibular, calcaneofibular, tibiocalcaneal, and superficial tibiotalar ligaments of the ankle were manufactured as deformable waveguides and tested at 10+% strain to verify linearity. The R2 value of all the ligaments when compared with a linear regression model was above 0.996 between the operating range of 0-6% strain. Then the joint complex as a whole was manipulated in the sagittal and coronal planes, providing evidence that there were unique behaviours in the ligament stretch demonstrated in each discrete plantar position, dorsiflexion, plantarflexion, inversion, and eversion. This could then be used in a control scheme for the joint to identify the planar position of the joint, which could then be used to drive and sense two planes of a prosthetic foot. This would ultimately improve balance and stability by permitting the foot to adapt to the floor in both planes with anatomical-like compliance, while allowing for the prediction of the geometry for a control scheme with active control for balance and stability.","abstract_has_math":false,"creators":["Clark, James Derek"],"institution":"University of York","degree_name":"M.Sc by research","degree_level":"masters","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Peter, Ellison","Babar, Jamil"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-12","date_published":"2025-12","updated_at":"2026-11-18T23:33:14Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["000900077423647X"],"render_values":[{"text":"0009-0007-7423-647X","href":"https://orcid.org/0009-0007-7423-647X","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/39341/13/JDC_Thesis_2.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A39341","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Peter, Ellison","Babar, Jamil"]},{"key":"dc:creator","label":"Author","values":["Clark, James Derek"]},{"key":"person:identifier.orcid","label":"ORCID","values":["000900077423647X"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-12"]},{"key":"dc:date.issued","label":"Date","values":["2025-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Physics, Engineering and Technology (York)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of York"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/39341/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["[1] S. Akhmejanov, N. Zhetenbayev, A. Sultan, A. Zhauyt, Y. Nurgizat, K. Ozhikenov, A.-A. Ayazbay, and A. Uzbekbayev. Design and analysis of an autonomous active ankle–foot prosthesis with 2-DoF. 25(16):4881. Publisher: Multidisciplinary Digital Publishing Institute. [2] O. Arfaie, B. Baysal, B. Ugurlu, and R. Unal. Ankatron: Design, development, and functional evaluation of 2-DoF robotic transtibial prosthesis. 14:24231–24247. [3] R. D. Bellman, M. A. Holgate, and T. G. Sugar. SPARKy 3: Design of an active robotic ankle prosthesis with two actuated degrees of freedom using regenerative kinetics. In 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics, pages 511–516. IEEE. [4] A. P. Boss and B. Hintermann. Anatomical study of the medial ankle ligament complex. 23(6):547–553. Publisher: SAGE Publications Inc. [5] C. L. Brockett and G. J. Chapman. Biomechanics of the ankle. 30(3):232–238. [6] K. J. Campbell, M. P. Michalski, K. J. Wilson, M. T. Goldsmith, C. A. Wijdicks, R. F. LaPrade, and T. O. Clanton. The ligament anatomy of the deltoid complex of the ankle: a qualitative and quantitative anatomical study. 96(8):e62. [7] Dominic Leake. Robotic knee event detection when preforming sit to STand motion. [8] E. M. Ficanha, M. Rastgaar, and K. R. Kaufman. Control of a 2-DOF powered ankle-foot mechanism. In 2015 IEEE International Conference on Robotics and Automation (ICRA), pages 6439–6444. ISSN: 1050-4729. [9] M. C. M. Fischer. Database of segmentations and surface models of bones of the entire lower body created from cadaver CT scans. 10(1):763. Publisher: Nature Publishing Group. 75 [10] A. J. Goldberg. Viscoelastic properties of silicone, polysulfide, and polyether im- pression materials. 53(5):1033–1039. [11] C. K. Harnett, H. Zhao, and R. F. Shepherd. Stretchable opti- cal fibers: Threads for strain-sensitive textiles. 2(9):1700087. eprint: https://advanced.onlinelibrary.wiley.com/doi/pdf/10.1002/admt.201700087. [12] J. Hertel. Functional anatomy, pathomechanics, and pathophysiology of lateral ankle instability. 37(4):364–375. [13] H. Hobara, Y. Kobayashi, T. Nakamura, N. Yamasaki, K. Nakazawa, M. Akai, and T. Ogata. Lower extremity joint kinematics of stair ascent in transfemoral amputees. 35(4):467. [14] D. P. Iliadis, D. N. Bourlos, D. S. Mastrokalos, E. Chronopoulos, and G. C. Babis. LARS artificial ligament versus ABC purely polyester ligament for anterior cruciate ligament reconstruction. 4(6):2325967116653359. Publisher: SAGE Publications Inc. [15] S.-O. Inc. Material safety data sheet SILC-PIG SERIES. [16] A. Isaacs-Itua and I. Sedki. Management of lower limb amputations. 79(4):205–210. Publisher: Mark Allen Group. [17] James D Clark. Event detection for powered limb prothesis. [18] L. Jami. Golgi tendon organs in mammalian skeletal muscle: functional properties and central actions. 72(3):623–666. Publisher: American Physiological Society. [19] B. Jamil and H. Rodrigue. Low-powered and resilient IR-based pigmented soft optoelectronic sensors. 14(33):38144–38152. Publisher: American Chemical Society. [20] W.-S. Jang, D.-Y. Kim, Y.-S. Choi, and Y.-J. Kim. Self-contained 2-DOF ankle-foot prosthesis with low-inertia extremity for agile walking on uneven terrain. 6(4):8134– 8141. Conference Name: IEEE Robotics and Automation Letters. 76 [21] J. Jin, K. Wang, L. Ren, Z. Qian, W. Liang, X. Xu, S. Zhao, X. Lu, D. Zhao, X. Wang, and L. Ren. Design of a flexible bionic ankle prosthesis based on subject- specific modeling of the human musculoskeletal system. 20(3):1008–1020. [22] T. Jotoku, M. Kinoshita, R. Okuda, and M. Abe. Anatomy of ligamentous structures in the tarsal sinus and canal. 27(7):533–538. Publisher: SAGE Publications Inc. [23] M. Kistler. VSDFullBody: The virtual skeleton database full body CT collection. [24] T. Lenzi, M. Cempini, L. J. Hargrove, and T. A. Kuiken. Actively variable transmis- sion for robotic knee prostheses. In 2017 IEEE International Conference on Robotics and Automation (ICRA), pages 6665–6671. [25] B. Li, G. Xu, Z. Teng, D. Luo, J. Pei, R. Chen, and S. Zhang. Intelligent ankle–foot prosthesis based on human structure and motion bionics. 21(1):119. [26] Z. Liao, M. Hossain, X. Yao, R. Navaratne, and G. Chagnon. A comprehensive thermo-viscoelastic experimental investigation of ecoflex polymer. 86:106478. [27] K. Matsui, M. Takao, Y. Tochigi, S. Ozeki, and M. Glazebrook. Anatomy of anterior talofibular ligament and calcaneofibular ligament for min- imally invasive surgery: a systematic review. 25(6):1795. eprint: https://onlinelibrary.wiley.com/doi/pdf/10.1007/s00167-016-4194-y. [28] F. Migliorini, A. Pintore, G. Vecchio, F. Oliva, F. Hildebrand, and N. Maffulli. Liga- ment advanced reinforcement system (LARS) synthetic graft for PCL reconstruction: systematic review and meta-analysis. 143(1):57–68. [29] C. E. Milner and R. W. Soames. Anatomy of the collateral ligaments of the human ankle joint. 19(11):757–760. [30] T. Nau and A. Teuschl. Ligament tissue engineering: The anterior cruciate ligament. In Organ Tissue Engineering, pages 1–18. Springer, Cham. 77 [31] M. Nordin. Basic Biomechanics of the Musculoskeletal System. Lippincott Williams & Wilkins. Google-Books-ID: P7Y6YgEACAAJ. [32] C. Piazza, C. D. Santina, G. Grioli, A. Bicchi, and M. G. Catalano. Analytical model and experimental testing of the SoftFoot: An adaptive robot foot for walking over obstacles and irregular terrains. 40:3290–3305. Conference Name: IEEE Transactions on Robotics. [33] R. M. Pierce, M. Zhu, K. J. Hunt, C. M. Orr, M. S. Myerson, and S. Li. Evaluation of articular morphology and congruency using a combination of 3 dimensional CT based bone segmentation and joint surface mapping. 7(4):2473011421S00879. [34] S. Rein, E. Hagert, U. Hanisch, S. Lwowski, A. Fieguth, and H. Zwipp. Immunohis- tochemical analysis of sensory nerve endings in ankle ligaments: A cadaver study. 197(1):64–76. [35] P. Renstrom, M. Wertz, S. Incavo, M. Pope, H. C. Ostgaard, S. Arms, and L. Haugh. Strain in the lateral ligaments of the ankle. 9(2):59–63. [36] F. Rositani, P. L. Antonucci, M. Minutoli, N. Giordano, and A. Villari. Infrared analysis of carbon blacks. 25(3):325–332. [37] F. Russell. A complete robotic knee as a tool for a better understanding of joint dynamics. Accepted: 2021-02-12T09:53:38Z Publisher: Imperial College London. [38] F. Russell, L. Gao, P. Ellison, and R. Vaidyanathan. Challenges in using compliant ligaments for position estimation within robotic joints. In 2017 International Con- ference on Rehabilitation Robotics (ICORR), pages 1471–1476. ISSN: 1945-7901. [39] F. Russell, R. Vaidyanathan, and P. Ellison. A kinematic model for the design of a bicondylar mechanical knee. In 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob), pages 750–755. IEEE. 78 [40] F. Russell, Y. Zhu, W. Hey, R. Vaidyanathan, and P. Ellison. A biomimicking design for mechanical knee joints. 13(5):056012. [41] J. Shintake, T. Nagai, and K. Ogishima. Sensitivity improvement of highly stretch- able capacitive strain sensors by hierarchical auxetic structures. 6:127. [42] Smooth-On, Inc. Mold star™ 15, 16, and 30 technical bulletin. Technical data sheet, Smooth-On, Inc., 2025. [43] Thomas Charles de ville McMullan. Assessing bio-inspired prosthetic knee for gait detection via motion capture. [44] C. To, T. L. Hellebrekers, and Y.-L. Park. Highly stretchable optical sensors for pressure, strain, and curvature measurement. In 2015 IEEE/RSJ International Con- ference on Intelligent Robots and Systems (IROS), pages 5898–5903. IEEE. [45] M. Tran, L. Gabert, M. Cempini, and T. Lenzi. A lightweight, efficient fully powered knee prosthesis with actively variable transmission. 4(2):1186–1193. [46] M. Tran, L. Gabert, S. Hood, and T. Lenzi. A lightweight robotic leg prosthesis replicating the biomechanics of the knee, ankle, and toe joint. 7(72):eabo3996. [47] H. T. T. Vu, D. Dong, H.-L. Cao, T. Verstraten, D. Lefeber, B. Vanderborght, and J. Geeroms. A review of gait phase detection algorithms for lower limb prostheses. 20(14):3972. Number: 14 Publisher: Multidisciplinary Digital Publishing Institute. [48] F. Wang, M. Wang, Q. He, X. Wang, P. Sun, Y. Ji, Y. Niu, F. Li, and J. Wei. Black tantalic oxide submicro-particles coating on PEEK fibers woven into fabrics as artificial ligaments with photothermal antibacterial effect and osteogenic activity for promoting ligament-bone healing. 133:195–208. [49] M. W. Whittle. Clinical gait analysis: A review. 15(3):369–387. 79 [50] H. Xiu, Y. Han, X. Wang, Y. Zhang, W. Liang, G. Wei, L. Ren, and L. Ren. Design, development, and clinical validation of a two degrees of freedom compliant ankle-foot prosthesis based on a 4-4r parallel mechanism. 172:104818. [51] S. Yun, J. Jeong, S. Mun, and K.-U. Kyung. A highly stretchable optical strain sen- sor monitoring dynamically large strain for deformation-controllable soft actuator. 30(10):105020. Publisher: IOP Publishing. [52] M. N. ´Alvarez, C. Rodr´ıguez-S´anchez, E. Huertas-Hoyas, G. Garc´ıa-Villamil-Neira, M. T. Espinoza-Cerda, L. P´erez-Delgado, E. Reina-Robles, I. B. Martin, A. J. del Ama, L. Ruiz-Ruiz, and A. R. Jim´enez-Ruiz. Predictors of fall risk in older adults using the g-STRIDE inertial sensor: an observational multicenter case–control study. 23(1):737."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["masters"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["M.Sc by research"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/39341/13/JDC_Thesis_2.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In current prosthetic devices permitting rotation, one-degree-of-freedom pin-joint-based ankle joints are primarily used, while two-degree-of-freedom devices remain in research; however, it has been shown that they improve the balance of the user compared to one degree of freedom. These research-based devices also predominantly make use of pin joints, which are inherently less kinematically accurate than rolling contact joints of the human anatomy. A two-degree-of-freedom rolling contact joint is multiplanar, and, therefore, rigid links to constrain the joint cannot be used, as this could only operate in one plane. Using soft multiplanar links analogous to ligaments would not only constrain the joint but also allow for characterisation of the joints by measuring the displacement of the links, which can be used to estimate joint angle for traditional control. A simplified version of the tibiotalar and subtalar joints of the ankle was made, forming a joint complex capable of motion in the coronal and sagittal planes. Silicone links were produced with a silicone-based infrared waveguide embedded to provide proprioception of the joint. The anterior talofibular, calcaneofibular, tibiocalcaneal, and superficial tibiotalar ligaments of the ankle were manufactured as deformable waveguides and tested at 10+% strain to verify linearity. The R2 value of all the ligaments when compared with a linear regression model was above 0.996 between the operating range of 0-6% strain. Then the joint complex as a whole was manipulated in the sagittal and coronal planes, providing evidence that there were unique behaviours in the ligament stretch demonstrated in each discrete plantar position, dorsiflexion, plantarflexion, inversion, and eversion. This could then be used in a control scheme for the joint to identify the planar position of the joint, which could then be used to drive and sense two planes of a prosthetic foot. This would ultimately improve balance and stability by permitting the foot to adapt to the floor in both planes with anatomical-like compliance, while allowing for the prediction of the geometry for a control scheme with active control for balance and stability."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Can a Biomimetic Ankle Joint with Proprioception Provide Feedback On Its Operating Environment?"]}]}],"canonical_facts":{"dc:contributor.advisor":["Peter, Ellison","Babar, Jamil"],"dc:creator":["Clark, James Derek"],"dc:date":["2025-12"],"dc:date.issued":["2025-12"],"dc:description.abstract":["In current prosthetic devices permitting rotation, one-degree-of-freedom pin-joint-based ankle joints are primarily used, while two-degree-of-freedom devices remain in research; however, it has been shown that they improve the balance of the user compared to one degree of freedom. These research-based devices also predominantly make use of pin joints, which are inherently less kinematically accurate than rolling contact joints of the human anatomy. A two-degree-of-freedom rolling contact joint is multiplanar, and, therefore, rigid links to constrain the joint cannot be used, as this could only operate in one plane. Using soft multiplanar links analogous to ligaments would not only constrain the joint but also allow for characterisation of the joints by measuring the displacement of the links, which can be used to estimate joint angle for traditional control. A simplified version of the tibiotalar and subtalar joints of the ankle was made, forming a joint complex capable of motion in the coronal and sagittal planes. Silicone links were produced with a silicone-based infrared waveguide embedded to provide proprioception of the joint. The anterior talofibular, calcaneofibular, tibiocalcaneal, and superficial tibiotalar ligaments of the ankle were manufactured as deformable waveguides and tested at 10+% strain to verify linearity. The R2 value of all the ligaments when compared with a linear regression model was above 0.996 between the operating range of 0-6% strain. Then the joint complex as a whole was manipulated in the sagittal and coronal planes, providing evidence that there were unique behaviours in the ligament stretch demonstrated in each discrete plantar position, dorsiflexion, plantarflexion, inversion, and eversion. This could then be used in a control scheme for the joint to identify the planar position of the joint, which could then be used to drive and sense two planes of a prosthetic foot. This would ultimately improve balance and stability by permitting the foot to adapt to the floor in both planes with anatomical-like compliance, while allowing for the prediction of the geometry for a control scheme with active control for balance and stability."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/39341/13/JDC_Thesis_2.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Physics, Engineering and Technology (York)"],"dc:publisher.institution":["University of York"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/39341/"],"dc:relation.references":["[1] S. Akhmejanov, N. Zhetenbayev, A. Sultan, A. Zhauyt, Y. Nurgizat, K. Ozhikenov, A.-A. Ayazbay, and A. Uzbekbayev. Design and analysis of an autonomous active ankle–foot prosthesis with 2-DoF. 25(16):4881. Publisher: Multidisciplinary Digital Publishing Institute. [2] O. Arfaie, B. Baysal, B. Ugurlu, and R. Unal. Ankatron: Design, development, and functional evaluation of 2-DoF robotic transtibial prosthesis. 14:24231–24247. [3] R. D. Bellman, M. A. Holgate, and T. G. Sugar. SPARKy 3: Design of an active robotic ankle prosthesis with two actuated degrees of freedom using regenerative kinetics. In 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics, pages 511–516. IEEE. [4] A. P. Boss and B. Hintermann. Anatomical study of the medial ankle ligament complex. 23(6):547–553. Publisher: SAGE Publications Inc. [5] C. L. Brockett and G. J. Chapman. Biomechanics of the ankle. 30(3):232–238. [6] K. J. Campbell, M. P. Michalski, K. J. Wilson, M. T. Goldsmith, C. A. Wijdicks, R. F. LaPrade, and T. O. Clanton. The ligament anatomy of the deltoid complex of the ankle: a qualitative and quantitative anatomical study. 96(8):e62. [7] Dominic Leake. Robotic knee event detection when preforming sit to STand motion. [8] E. M. Ficanha, M. Rastgaar, and K. R. Kaufman. Control of a 2-DOF powered ankle-foot mechanism. In 2015 IEEE International Conference on Robotics and Automation (ICRA), pages 6439–6444. ISSN: 1050-4729. [9] M. C. M. Fischer. Database of segmentations and surface models of bones of the entire lower body created from cadaver CT scans. 10(1):763. Publisher: Nature Publishing Group. 75 [10] A. J. Goldberg. Viscoelastic properties of silicone, polysulfide, and polyether im- pression materials. 53(5):1033–1039. [11] C. K. Harnett, H. Zhao, and R. F. Shepherd. Stretchable opti- cal fibers: Threads for strain-sensitive textiles. 2(9):1700087. eprint: https://advanced.onlinelibrary.wiley.com/doi/pdf/10.1002/admt.201700087. [12] J. Hertel. Functional anatomy, pathomechanics, and pathophysiology of lateral ankle instability. 37(4):364–375. [13] H. Hobara, Y. Kobayashi, T. Nakamura, N. Yamasaki, K. Nakazawa, M. Akai, and T. Ogata. Lower extremity joint kinematics of stair ascent in transfemoral amputees. 35(4):467. [14] D. P. Iliadis, D. N. Bourlos, D. S. Mastrokalos, E. Chronopoulos, and G. C. Babis. LARS artificial ligament versus ABC purely polyester ligament for anterior cruciate ligament reconstruction. 4(6):2325967116653359. Publisher: SAGE Publications Inc. [15] S.-O. Inc. Material safety data sheet SILC-PIG SERIES. [16] A. Isaacs-Itua and I. Sedki. Management of lower limb amputations. 79(4):205–210. Publisher: Mark Allen Group. [17] James D Clark. Event detection for powered limb prothesis. [18] L. Jami. Golgi tendon organs in mammalian skeletal muscle: functional properties and central actions. 72(3):623–666. Publisher: American Physiological Society. [19] B. Jamil and H. Rodrigue. Low-powered and resilient IR-based pigmented soft optoelectronic sensors. 14(33):38144–38152. Publisher: American Chemical Society. [20] W.-S. Jang, D.-Y. Kim, Y.-S. Choi, and Y.-J. Kim. Self-contained 2-DOF ankle-foot prosthesis with low-inertia extremity for agile walking on uneven terrain. 6(4):8134– 8141. Conference Name: IEEE Robotics and Automation Letters. 76 [21] J. Jin, K. Wang, L. Ren, Z. Qian, W. Liang, X. Xu, S. Zhao, X. Lu, D. Zhao, X. Wang, and L. Ren. Design of a flexible bionic ankle prosthesis based on subject- specific modeling of the human musculoskeletal system. 20(3):1008–1020. [22] T. Jotoku, M. Kinoshita, R. Okuda, and M. Abe. Anatomy of ligamentous structures in the tarsal sinus and canal. 27(7):533–538. Publisher: SAGE Publications Inc. [23] M. Kistler. VSDFullBody: The virtual skeleton database full body CT collection. [24] T. Lenzi, M. Cempini, L. J. Hargrove, and T. A. Kuiken. Actively variable transmis- sion for robotic knee prostheses. In 2017 IEEE International Conference on Robotics and Automation (ICRA), pages 6665–6671. [25] B. Li, G. Xu, Z. Teng, D. Luo, J. Pei, R. Chen, and S. Zhang. Intelligent ankle–foot prosthesis based on human structure and motion bionics. 21(1):119. [26] Z. Liao, M. Hossain, X. Yao, R. Navaratne, and G. Chagnon. A comprehensive thermo-viscoelastic experimental investigation of ecoflex polymer. 86:106478. [27] K. Matsui, M. Takao, Y. Tochigi, S. Ozeki, and M. Glazebrook. Anatomy of anterior talofibular ligament and calcaneofibular ligament for min- imally invasive surgery: a systematic review. 25(6):1795. eprint: https://onlinelibrary.wiley.com/doi/pdf/10.1007/s00167-016-4194-y. [28] F. Migliorini, A. Pintore, G. Vecchio, F. Oliva, F. Hildebrand, and N. Maffulli. Liga- ment advanced reinforcement system (LARS) synthetic graft for PCL reconstruction: systematic review and meta-analysis. 143(1):57–68. [29] C. E. Milner and R. W. Soames. Anatomy of the collateral ligaments of the human ankle joint. 19(11):757–760. [30] T. Nau and A. Teuschl. Ligament tissue engineering: The anterior cruciate ligament. In Organ Tissue Engineering, pages 1–18. Springer, Cham. 77 [31] M. Nordin. Basic Biomechanics of the Musculoskeletal System. Lippincott Williams & Wilkins. Google-Books-ID: P7Y6YgEACAAJ. [32] C. Piazza, C. D. Santina, G. Grioli, A. Bicchi, and M. G. Catalano. Analytical model and experimental testing of the SoftFoot: An adaptive robot foot for walking over obstacles and irregular terrains. 40:3290–3305. Conference Name: IEEE Transactions on Robotics. [33] R. M. Pierce, M. Zhu, K. J. Hunt, C. M. Orr, M. S. Myerson, and S. Li. Evaluation of articular morphology and congruency using a combination of 3 dimensional CT based bone segmentation and joint surface mapping. 7(4):2473011421S00879. [34] S. Rein, E. Hagert, U. Hanisch, S. Lwowski, A. Fieguth, and H. Zwipp. Immunohis- tochemical analysis of sensory nerve endings in ankle ligaments: A cadaver study. 197(1):64–76. [35] P. Renstrom, M. Wertz, S. Incavo, M. Pope, H. C. Ostgaard, S. Arms, and L. Haugh. Strain in the lateral ligaments of the ankle. 9(2):59–63. [36] F. Rositani, P. L. Antonucci, M. Minutoli, N. Giordano, and A. Villari. Infrared analysis of carbon blacks. 25(3):325–332. [37] F. Russell. A complete robotic knee as a tool for a better understanding of joint dynamics. Accepted: 2021-02-12T09:53:38Z Publisher: Imperial College London. [38] F. Russell, L. Gao, P. Ellison, and R. Vaidyanathan. Challenges in using compliant ligaments for position estimation within robotic joints. In 2017 International Con- ference on Rehabilitation Robotics (ICORR), pages 1471–1476. ISSN: 1945-7901. [39] F. Russell, R. Vaidyanathan, and P. Ellison. A kinematic model for the design of a bicondylar mechanical knee. In 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob), pages 750–755. IEEE. 78 [40] F. Russell, Y. Zhu, W. Hey, R. Vaidyanathan, and P. Ellison. A biomimicking design for mechanical knee joints. 13(5):056012. [41] J. Shintake, T. Nagai, and K. Ogishima. Sensitivity improvement of highly stretch- able capacitive strain sensors by hierarchical auxetic structures. 6:127. [42] Smooth-On, Inc. Mold star™ 15, 16, and 30 technical bulletin. Technical data sheet, Smooth-On, Inc., 2025. [43] Thomas Charles de ville McMullan. Assessing bio-inspired prosthetic knee for gait detection via motion capture. [44] C. To, T. L. Hellebrekers, and Y.-L. Park. Highly stretchable optical sensors for pressure, strain, and curvature measurement. In 2015 IEEE/RSJ International Con- ference on Intelligent Robots and Systems (IROS), pages 5898–5903. IEEE. [45] M. Tran, L. Gabert, M. Cempini, and T. Lenzi. A lightweight, efficient fully powered knee prosthesis with actively variable transmission. 4(2):1186–1193. [46] M. Tran, L. Gabert, S. Hood, and T. Lenzi. A lightweight robotic leg prosthesis replicating the biomechanics of the knee, ankle, and toe joint. 7(72):eabo3996. [47] H. T. T. Vu, D. Dong, H.-L. Cao, T. Verstraten, D. Lefeber, B. Vanderborght, and J. Geeroms. A review of gait phase detection algorithms for lower limb prostheses. 20(14):3972. Number: 14 Publisher: Multidisciplinary Digital Publishing Institute. [48] F. Wang, M. Wang, Q. He, X. Wang, P. Sun, Y. Ji, Y. Niu, F. Li, and J. Wei. Black tantalic oxide submicro-particles coating on PEEK fibers woven into fabrics as artificial ligaments with photothermal antibacterial effect and osteogenic activity for promoting ligament-bone healing. 133:195–208. [49] M. W. Whittle. Clinical gait analysis: A review. 15(3):369–387. 79 [50] H. Xiu, Y. Han, X. Wang, Y. Zhang, W. Liang, G. Wei, L. Ren, and L. Ren. Design, development, and clinical validation of a two degrees of freedom compliant ankle-foot prosthesis based on a 4-4r parallel mechanism. 172:104818. [51] S. Yun, J. Jeong, S. Mun, and K.-U. Kyung. A highly stretchable optical strain sen- sor monitoring dynamically large strain for deformation-controllable soft actuator. 30(10):105020. Publisher: IOP Publishing. [52] M. N. ´Alvarez, C. Rodr´ıguez-S´anchez, E. Huertas-Hoyas, G. Garc´ıa-Villamil-Neira, M. T. Espinoza-Cerda, L. P´erez-Delgado, E. Reina-Robles, I. B. Martin, A. J. del Ama, L. Ruiz-Ruiz, and A. R. Jim´enez-Ruiz. Predictors of fall risk in older adults using the g-STRIDE inertial sensor: an observational multicenter case–control study. 23(1):737."],"dcterms:accessrights":["public"],"dc:title":["Can a Biomimetic Ankle Joint with Proprioception Provide Feedback On Its Operating Environment?"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["masters"],"dc:type.qualificationname":["M.Sc by research"],"person:identifier.orcid":["000900077423647X"]},"updated_at":"2026-11-18T23:33:14Z"}