{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:39353"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:39353","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"AI-integrated treatment planning and real-time guidance for ultrasound-guided high intensity focused ultrasound (USgHIFU)","abstract":"High Intensity Focused Ultrasound (HIFU) is a non-invasive, non-ionising therapeutic technology that uses acoustic energy to ablate tumours at depth in the body. Compared with traditional surgery, it has the potential to reduce recovery time, minimise side-effects, and improve patient safety. However, challenges in treatment planning and imaging guidance have limited its widespread adoption. This thesis presents an AI-integrated, ultrasound-guided HIFU system to address these challenges, combining real-time multi-organ segmentation with collaborative robotics (co-robotics) for patient-specific planning and guidance. These advances are demonstrated in the context of benign symptomatic thyroid nodules; however, the core methods and results developed could be broadly applied to a variety of treatment planning and ultrasound imaging tasks. Initial work with lung ultrasound phantoms established lightweight Deep Learning (DL) models for live B-mode segmentation (mDSC = 0.74, 33 FPS), showing promise for future diagnostic systems. These methods were then extended to enable a co-robotic 3D ultrasound system, which achieved state-of-the-art geometric reconstruction accuracy on a purpose-designed quality assurance phantom (DSC-3D = 0.94 +- 0.01, HD95 = 1.17 +- 0.12 mm), approaching the spatial resolution limits imposed by ultrasound imaging. In thyroid ultrasound, the co-robotic 3D ultrasound system allowed live multi-organ reconstruction and thyroid volumetry which closely matched the CT ground-truth (37.7 +- 1.3 mL vs. 37.9 +- 1.8 mL). This outperformed the current clinical standard ultrasound technique, with implications for radioiodine dosimetry and future semi-automated HIFU planning. Finally, to support clinical translation, a new UK ultrasound dataset was curated, enabled by a novel data extraction tool which extracted key diagnostic information from free-text radiology reports (micro-average sensitivity, specificity, and F1-score of 0.97, 0.96, and 0.94). Overall, this work represents progress towards addressing key barriers to wider HIFU adoption, including long treatment times, complex manual planning, and inter-operator dependence. Addressing these will be key to HIFU’s role in improving patient outcomes in the future.","abstract_html":"High Intensity Focused Ultrasound (HIFU) is a non-invasive, non-ionising therapeutic technology that uses acoustic energy to ablate tumours at depth in the body. Compared with traditional surgery, it has the potential to reduce recovery time, minimise side-effects, and improve patient safety. However, challenges in treatment planning and imaging guidance have limited its widespread adoption. This thesis presents an AI-integrated, ultrasound-guided HIFU system to address these challenges, combining real-time multi-organ segmentation with collaborative robotics (co-robotics) for patient-specific planning and guidance. These advances are demonstrated in the context of benign symptomatic thyroid nodules; however, the core methods and results developed could be broadly applied to a variety of treatment planning and ultrasound imaging tasks. Initial work with lung ultrasound phantoms established lightweight Deep Learning (DL) models for live B-mode segmentation (mDSC = 0.74, 33 FPS), showing promise for future diagnostic systems. These methods were then extended to enable a co-robotic 3D ultrasound system, which achieved state-of-the-art geometric reconstruction accuracy on a purpose-designed quality assurance phantom (DSC-3D = 0.94 +- 0.01, HD95 = 1.17 +- 0.12 mm), approaching the spatial resolution limits imposed by ultrasound imaging. In thyroid ultrasound, the co-robotic 3D ultrasound system allowed live multi-organ reconstruction and thyroid volumetry which closely matched the CT ground-truth (37.7 +- 1.3 mL vs. 37.9 +- 1.8 mL). This outperformed the current clinical standard ultrasound technique, with implications for radioiodine dosimetry and future semi-automated HIFU planning. Finally, to support clinical translation, a new UK ultrasound dataset was curated, enabled by a novel data extraction tool which extracted key diagnostic information from free-text radiology reports (micro-average sensitivity, specificity, and F1-score of 0.97, 0.96, and 0.94). Overall, this work represents progress towards addressing key barriers to wider HIFU adoption, including long treatment times, complex manual planning, and inter-operator dependence. Addressing these will be key to HIFU’s role in improving patient outcomes in the future.","abstract_has_math":false,"creators":["Howell, Lewis James"],"institution":"University of Leeds","degree_name":"Integrated Ph.D and Master","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["McLaughlan, James","Chandler, James","Wah, Tze Min"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-08","date_published":"2026-08","updated_at":"2026-11-18T23:33:14Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/S024336/1","EP/V04799X/1."],"render_values":[{"text":"EP/S024336/1","href":null,"code":true},{"text":"EP/V04799X/1.","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000348074087"],"render_values":[{"text":"0000-0003-4807-4087","href":"https://orcid.org/0000-0003-4807-4087","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/39353/1/Howell_LJ_ComputerScience_PhD_2026.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A39353","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["McLaughlan, James","Chandler, James","Wah, Tze Min"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Engineering and Physical Sciences Research Council (EPSRC)"]},{"key":"dc:creator","label":"Author","values":["Howell, Lewis James"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000348074087"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-08"]},{"key":"dc:date.issued","label":"Date","values":["2026-08"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Computing (Leeds)","School of Electronic & Electrical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/39353/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Integrated Ph.D and Master"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/S024336/1","EP/V04799X/1."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/39353/1/Howell_LJ_ComputerScience_PhD_2026.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["High Intensity Focused Ultrasound (HIFU) is a non-invasive, non-ionising therapeutic technology that uses acoustic energy to ablate tumours at depth in the body. Compared with traditional surgery, it has the potential to reduce recovery time, minimise side-effects, and improve patient safety. However, challenges in treatment planning and imaging guidance have limited its widespread adoption. This thesis presents an AI-integrated, ultrasound-guided HIFU system to address these challenges, combining real-time multi-organ segmentation with collaborative robotics (co-robotics) for patient-specific planning and guidance. These advances are demonstrated in the context of benign symptomatic thyroid nodules; however, the core methods and results developed could be broadly applied to a variety of treatment planning and ultrasound imaging tasks. Initial work with lung ultrasound phantoms established lightweight Deep Learning (DL) models for live B-mode segmentation (mDSC = 0.74, 33 FPS), showing promise for future diagnostic systems. These methods were then extended to enable a co-robotic 3D ultrasound system, which achieved state-of-the-art geometric reconstruction accuracy on a purpose-designed quality assurance phantom (DSC-3D = 0.94 +- 0.01, HD95 = 1.17 +- 0.12 mm), approaching the spatial resolution limits imposed by ultrasound imaging. In thyroid ultrasound, the co-robotic 3D ultrasound system allowed live multi-organ reconstruction and thyroid volumetry which closely matched the CT ground-truth (37.7 +- 1.3 mL vs. 37.9 +- 1.8 mL). This outperformed the current clinical standard ultrasound technique, with implications for radioiodine dosimetry and future semi-automated HIFU planning. Finally, to support clinical translation, a new UK ultrasound dataset was curated, enabled by a novel data extraction tool which extracted key diagnostic information from free-text radiology reports (micro-average sensitivity, specificity, and F1-score of 0.97, 0.96, and 0.94). Overall, this work represents progress towards addressing key barriers to wider HIFU adoption, including long treatment times, complex manual planning, and inter-operator dependence. Addressing these will be key to HIFU’s role in improving patient outcomes in the future."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["AI-integrated treatment planning and real-time guidance for ultrasound-guided high intensity focused ultrasound (USgHIFU)"]}]}],"canonical_facts":{"dc:contributor.advisor":["McLaughlan, James","Chandler, James","Wah, Tze Min"],"dc:contributor.sponsor":["Engineering and Physical Sciences Research Council (EPSRC)"],"dc:creator":["Howell, Lewis James"],"dc:date":["2026-08"],"dc:date.issued":["2026-08"],"dc:description.abstract":["High Intensity Focused Ultrasound (HIFU) is a non-invasive, non-ionising therapeutic technology that uses acoustic energy to ablate tumours at depth in the body. Compared with traditional surgery, it has the potential to reduce recovery time, minimise side-effects, and improve patient safety. However, challenges in treatment planning and imaging guidance have limited its widespread adoption. This thesis presents an AI-integrated, ultrasound-guided HIFU system to address these challenges, combining real-time multi-organ segmentation with collaborative robotics (co-robotics) for patient-specific planning and guidance. These advances are demonstrated in the context of benign symptomatic thyroid nodules; however, the core methods and results developed could be broadly applied to a variety of treatment planning and ultrasound imaging tasks. Initial work with lung ultrasound phantoms established lightweight Deep Learning (DL) models for live B-mode segmentation (mDSC = 0.74, 33 FPS), showing promise for future diagnostic systems. These methods were then extended to enable a co-robotic 3D ultrasound system, which achieved state-of-the-art geometric reconstruction accuracy on a purpose-designed quality assurance phantom (DSC-3D = 0.94 +- 0.01, HD95 = 1.17 +- 0.12 mm), approaching the spatial resolution limits imposed by ultrasound imaging. In thyroid ultrasound, the co-robotic 3D ultrasound system allowed live multi-organ reconstruction and thyroid volumetry which closely matched the CT ground-truth (37.7 +- 1.3 mL vs. 37.9 +- 1.8 mL). This outperformed the current clinical standard ultrasound technique, with implications for radioiodine dosimetry and future semi-automated HIFU planning. Finally, to support clinical translation, a new UK ultrasound dataset was curated, enabled by a novel data extraction tool which extracted key diagnostic information from free-text radiology reports (micro-average sensitivity, specificity, and F1-score of 0.97, 0.96, and 0.94). Overall, this work represents progress towards addressing key barriers to wider HIFU adoption, including long treatment times, complex manual planning, and inter-operator dependence. Addressing these will be key to HIFU’s role in improving patient outcomes in the future."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/S024336/1","EP/V04799X/1."],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/39353/1/Howell_LJ_ComputerScience_PhD_2026.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Computing (Leeds)","School of Electronic & Electrical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/39353/"],"dcterms:accessrights":["public"],"dc:title":["AI-integrated treatment planning and real-time guidance for ultrasound-guided high intensity focused ultrasound (USgHIFU)"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Integrated Ph.D and Master"],"person:identifier.orcid":["0000000348074087"]},"updated_at":"2026-11-18T23:33:14Z"}