{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:4570"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:4570","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Ultrasonic phased array techniques using switched-mode excitation","abstract":"Ultrasound is predominantly an ‘active’ sensing modality, with information obtained by transmission of an acoustic wave, followed by analysis of received signals. Transmission occurs when electrical signals are converted to acoustic signals. This thesis covers the design and application of these electrical signals to an array transducer. As an introduction, the development of a bespoke ultrasound array research platform is discussed. This enabling technology is built around switched-mode excitation: a method of approximating an analogue waveform by selecting between discrete voltage levels. The use of switched-mode methods has led to three major topics of research. Firstly, a transmit beamformer architecture that provides fine control of excitation sequence timing using embedded-phase locked loops is presented. This enables accurate implementation of firing sequences or phasing between transducer elements, thus minimizing time-quantization error, and providing an improved representation of the expected pressure field. An introduction to transmit beamforming is given, the impact of timequantization is discussed, and the transmit beamformer’s performance is demonstrated. Secondly, a method of arbitrary waveform generation using switched-mode excitation is described. The method encodes width-modulated sequences of three or five discrete voltage levels, that, once passed through a transducer, give close approximation to the desired arbitrary waveform. Applications include: power control, pulse shaping, and array apodization. Each application is demonstrated by simulation and experimentation. An extension to the method is shown for ‘chirp’ coded imaging, demonstrating the capability for generation of frequency modulated waveforms. The improvement in image quality when compared with conventional square-wave, ‘pseudo-chirp’ excitation signals is shown. Lastly, the performance of the width-modulated signals is further extended so as to remove unwanted third-harmonic content whilst still maintaining pulse amplitude control.Removal of the third harmonic reduces harmonic distortion, has benefits in applications such as harmonic imaging, and extends the use of switched-mode operation with wide bandwidth transducers.","abstract_html":"Ultrasound is predominantly an ‘active’ sensing modality, with information obtained by transmission of an acoustic wave, followed by analysis of received signals. Transmission occurs when electrical signals are converted to acoustic signals. This thesis covers the design and application of these electrical signals to an array transducer. As an introduction, the development of a bespoke ultrasound array research platform is discussed. This enabling technology is built around switched-mode excitation: a method of approximating an analogue waveform by selecting between discrete voltage levels. The use of switched-mode methods has led to three major topics of research. Firstly, a transmit beamformer architecture that provides fine control of excitation sequence timing using embedded-phase locked loops is presented. This enables accurate implementation of firing sequences or phasing between transducer elements, thus minimizing time-quantization error, and providing an improved representation of the expected pressure field. An introduction to transmit beamforming is given, the impact of timequantization is discussed, and the transmit beamformer’s performance is demonstrated. Secondly, a method of arbitrary waveform generation using switched-mode excitation is described. The method encodes width-modulated sequences of three or five discrete voltage levels, that, once passed through a transducer, give close approximation to the desired arbitrary waveform. Applications include: power control, pulse shaping, and array apodization. Each application is demonstrated by simulation and experimentation. An extension to the method is shown for ‘chirp’ coded imaging, demonstrating the capability for generation of frequency modulated waveforms. The improvement in image quality when compared with conventional square-wave, ‘pseudo-chirp’ excitation signals is shown. Lastly, the performance of the width-modulated signals is further extended so as to remove unwanted third-harmonic content whilst still maintaining pulse amplitude control.Removal of the third harmonic reduces harmonic distortion, has benefits in applications such as harmonic imaging, and extends the use of switched-mode operation with wide bandwidth transducers.","abstract_has_math":false,"creators":["Smith, Peter Raymond"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Freear, S."],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-18T21:24:03Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.581703"],"render_values":[{"text":"uk.bl.ethos.581703","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/4570/1/P.%20R.%20Smith%20Thesis.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A4570","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Freear, S."]},{"key":"dc:creator","label":"Author","values":["Smith, Peter Raymond"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Electronic & Electrical Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/4570/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.581703"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/4570/1/P.%20R.%20Smith%20Thesis.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ultrasound is predominantly an ‘active’ sensing modality, with information obtained by transmission of an acoustic wave, followed by analysis of received signals. Transmission occurs when electrical signals are converted to acoustic signals. This thesis covers the design and application of these electrical signals to an array transducer. As an introduction, the development of a bespoke ultrasound array research platform is discussed. This enabling technology is built around switched-mode excitation: a method of approximating an analogue waveform by selecting between discrete voltage levels. The use of switched-mode methods has led to three major topics of research. Firstly, a transmit beamformer architecture that provides fine control of excitation sequence timing using embedded-phase locked loops is presented. This enables accurate implementation of firing sequences or phasing between transducer elements, thus minimizing time-quantization error, and providing an improved representation of the expected pressure field. An introduction to transmit beamforming is given, the impact of timequantization is discussed, and the transmit beamformer’s performance is demonstrated. Secondly, a method of arbitrary waveform generation using switched-mode excitation is described. The method encodes width-modulated sequences of three or five discrete voltage levels, that, once passed through a transducer, give close approximation to the desired arbitrary waveform. Applications include: power control, pulse shaping, and array apodization. Each application is demonstrated by simulation and experimentation. An extension to the method is shown for ‘chirp’ coded imaging, demonstrating the capability for generation of frequency modulated waveforms. The improvement in image quality when compared with conventional square-wave, ‘pseudo-chirp’ excitation signals is shown. Lastly, the performance of the width-modulated signals is further extended so as to remove unwanted third-harmonic content whilst still maintaining pulse amplitude control.Removal of the third harmonic reduces harmonic distortion, has benefits in applications such as harmonic imaging, and extends the use of switched-mode operation with wide bandwidth transducers."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Ultrasonic phased array techniques using switched-mode excitation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Freear, S."],"dc:creator":["Smith, Peter Raymond"],"dc:date":["2013"],"dc:date.issued":["2013"],"dc:description.abstract":["Ultrasound is predominantly an ‘active’ sensing modality, with information obtained by transmission of an acoustic wave, followed by analysis of received signals. Transmission occurs when electrical signals are converted to acoustic signals. This thesis covers the design and application of these electrical signals to an array transducer. As an introduction, the development of a bespoke ultrasound array research platform is discussed. This enabling technology is built around switched-mode excitation: a method of approximating an analogue waveform by selecting between discrete voltage levels. The use of switched-mode methods has led to three major topics of research. Firstly, a transmit beamformer architecture that provides fine control of excitation sequence timing using embedded-phase locked loops is presented. This enables accurate implementation of firing sequences or phasing between transducer elements, thus minimizing time-quantization error, and providing an improved representation of the expected pressure field. An introduction to transmit beamforming is given, the impact of timequantization is discussed, and the transmit beamformer’s performance is demonstrated. Secondly, a method of arbitrary waveform generation using switched-mode excitation is described. The method encodes width-modulated sequences of three or five discrete voltage levels, that, once passed through a transducer, give close approximation to the desired arbitrary waveform. Applications include: power control, pulse shaping, and array apodization. Each application is demonstrated by simulation and experimentation. An extension to the method is shown for ‘chirp’ coded imaging, demonstrating the capability for generation of frequency modulated waveforms. The improvement in image quality when compared with conventional square-wave, ‘pseudo-chirp’ excitation signals is shown. Lastly, the performance of the width-modulated signals is further extended so as to remove unwanted third-harmonic content whilst still maintaining pulse amplitude control.Removal of the third harmonic reduces harmonic distortion, has benefits in applications such as harmonic imaging, and extends the use of switched-mode operation with wide bandwidth transducers."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.581703"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/4570/1/P.%20R.%20Smith%20Thesis.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["School of Electronic & Electrical Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/4570/"],"dcterms:accessrights":["public"],"dc:title":["Ultrasonic phased array techniques using switched-mode excitation"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T21:24:03Z"}