{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:8569"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:8569","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Tissue manipulation using nano-particles ferrofluids for minimal access surgical applications","abstract":"Nano-scale Iron-Oxide ferrofluids exhibit a special property, ‘superparamagnetism’, that induces an attractive force toward an external magnetic field. The aim of this project is to investigate the use of ferrofluids for tissue retraction during Minimally Access Surgery (MAS). In the in-vivo porcine experiments, 0.3 ml of ferrofluid (200 mg/ml concentration) containing 10 nm particles is injected subserosally into the small bowel, respectively. A 0.6 T magnetic field is created using a combination of 10 mm and 20 mm diameter Neodymium Iron Boron magnets. The vertical retraction distance is measured up to 80 mm and video-recorded. The results demonstrate the capacity of ferrofluid to facilitate the tissue manipulation and analysis of the migration of the particles within the tissue using micro computed tomography (CT). A theoretical model developed to validate the experimental results is also beneficial for predicting retraction force. In conclusion, this feasibility study provides a protocol for systematically using small volumes of ferrofluid, without the need to mechanically grasp the tissue.","abstract_html":"Nano-scale Iron-Oxide ferrofluids exhibit a special property, ‘superparamagnetism’, that induces an attractive force toward an external magnetic field. The aim of this project is to investigate the use of ferrofluids for tissue retraction during Minimally Access Surgery (MAS). In the in-vivo porcine experiments, 0.3 ml of ferrofluid (200 mg/ml concentration) containing 10 nm particles is injected subserosally into the small bowel, respectively. A 0.6 T magnetic field is created using a combination of 10 mm and 20 mm diameter Neodymium Iron Boron magnets. The vertical retraction distance is measured up to 80 mm and video-recorded. The results demonstrate the capacity of ferrofluid to facilitate the tissue manipulation and analysis of the migration of the particles within the tissue using micro computed tomography (CT). A theoretical model developed to validate the experimental results is also beneficial for predicting retraction force. In conclusion, this feasibility study provides a protocol for systematically using small volumes of ferrofluid, without the need to mechanically grasp the tissue.","abstract_has_math":false,"creators":["Lin, Yu-Sheng"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Neville , Anne","Liskiewicz , Tomasz","Roshan, Rupesh"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-09","date_published":"2014-09","updated_at":"2026-11-18T21:30:02Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.644771"],"render_values":[{"text":"uk.bl.ethos.644771","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/8569/1/Yu-Sheng%20Lin_PhD%20Thesis_Final.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A8569","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Neville , Anne","Liskiewicz , Tomasz","Roshan, Rupesh"]},{"key":"dc:creator","label":"Author","values":["Lin, Yu-Sheng"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-09"]},{"key":"dc:date.issued","label":"Date","values":["2014-09"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Faculty of Engineering (Leeds)","School of Mechanical Engineering (Leeds)","Institute of Engineering Thermofluids, Surfaces & Interfaces (iETSI) (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/8569/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["ACHANTA, S. C. 2008. Investigation of Friction from Nano to Macro Force Scale Under Reciprocating Sliding Conditions. Degree of Doctor, Katholieke Universiteit Leuven. AL KHABURI, J. A. J. 2010. Pressure Mapping of Medical Compression Bandages Used for Venous Leg Ulcer Treatment. PhD, University of Leeds. ALASWAD, F. D. 2013. Treatment Options of Laparoscopic Complications. Journal of the American Society of Abdominal Surgeons. AOYAMA, K., TAKENAKA I FAU - SATA, T., SATA T FAU - SHIGEMATSU, A. & SHIGEMATSU, A. 1996. Use of the Fibrescope-Video Camera System for Difficult Tracheal Intubation. British Journal of Anaesthesia, 77, 662-664. AUSTIN, R. C. 2009. Natural orifice translumenal endoscopic surgery (NOTES) - scar free or scary? Ann R Coll Surg Engl., 91, 192-194. AUTUMN, K. & PEATTIE, A. M. 2002. Mechanisms of Adhesion in Geckos. Integrative and Comparative Biology, 42, 1081-1090. BAILEY, L. O., LIPPIATT S FAU - BIANCANELLO, F. S., BIANCANELLO FS FAU - RIDDER, S. D., RIDDER SD FAU - WASHBURN, N. R. & WASHBURN, N. R. 2005. The Quantification of Cellular Viability and Inflammatory Response to Stainless Steel Alloys. Biomaterials, 26, 5296-5302. BALLANTYNE, G. H. 2002. The pitfalls of laparoscopic surgery: challenges for robotics and telerobotic surgery. Surgical Laparoscopy Endoscopy Percutaneous Techniques, 12, 1-5. BANKS, W. H. & MILL, C. C. 1953. Tacky Adhesion - A Preliminary Study. Journal of Colloid and Interface Science, 8, 137-147. BEST, S. L., BERGS, R., GEDEON, M., PARAMO, J., FERNANDEZ, R., CADEDDU, J. A. & SCOTT, D. J. 2011. Maximizing coupling strength of magnetically anchored surgical instruments: how thick can we go? Surgical Endoscopy, 25, 153-159. BEST, S. L. & CADEDDU, J. A. 2010. Use of Magnetic Anchoring and Guidance Systems to Facilitate Single Trocar Laparoscopy. Current Urology Reports, 11, 29-32. BISHOFF, J. T., ALLAF ME FAU - KIRKELS, W., KIRKELS W FAU - MOORE, R. G., MOORE RG FAU - KAVOUSSI, L. R., KAVOUSSI LR FAU - SCHRODER, F. & SCHRODER, F. 1999a. Laparoscopic bowel injury: incidence and clinical presentation. The Journal of Urology, 161, 887-890. BISHOFF, J. T., ALLAF, M. E., KIRKELS, W., MOORE, R. G., KAVOUSSI, L. R. & SCHRODER, F. 1999b. Laparoscopic Bowel Injury: Incidence And Clinical Presentation. The Journal of Urology, 161, 887-890. BOROS, M., RŐTH, E., LÁZÁR, G. & GAÁL, C. 2006. Surgical Techniques Textbook for medical students, University of Szeged. BRETTHAUER, M., HOFF GS FAU - THIIS-EVENSEN, E., THIIS-EVENSEN E FAU - HUPPERTZ-HAUSS, G., HUPPERTZ-HAUSS G FAU - SKOVLUND, E. & SKOVLUND, E. 2003. Air and Carbon Dioxide Volumes Insufflated During Colonoscopy. Gastrointestinal Endoscopy, 58, 203-206. BRETTHAUER, M., LYNGE AB FAU - THIIS-EVENSEN, E., THIIS-EVENSEN E FAU - HOFF, G., HOFF G FAU - FAUSA, O., FAUSA O FAU - AABAKKEN, L. & AABAKKEN, L. 2005. Carbon Dioxide Insufflation in Colonoscopy: Safe and Effective in Sedated Patients. Journal of Endoscopy, 37, 706-709. BRETTHAUER, M., SEIP B FAU - AASEN, S., AASEN S FAU - KORDAL, M., KORDAL M FAU - HOFF, G., HOFF G FAU - AABAKKEN, L. & AABAKKEN, L. 2007. Carbon Dioxide Insufflation for More Comfortable Endoscopic Retrograde Cholangiopancreatography: A Randomized, Controlled, Double-Blind Trial. Journal of Endoscopy, 39, 58-64. BROWN, T. H. & IRVING, M. H. 1995. Introduction to Minimal Access Surgery, BMJ Publishing Group. CADEDDU, J., FERNANDEZ, R., DESAI, M., BERGS, R., TRACY, C., TANG, S.-J., RAO, P., DESAI, M. & SCOTT, D. 2009. Novel magnetically guided intra-abdominal camera to facilitate laparoendoscopic single-site surgery: initial human experience. Surgical Endoscopy, 23, 1894-1899. CANTILLON, P. J., BRENNAN, P. J., TUGWELL, J., O’DONOGHUE, K. & CAHILL, R. A. Electropermanent Magnets for Transabdominal Anchoring. 21st International Congress of the European Association for Endoscopic Surgery (EAES), 2013 Vienna, Austria. CARON, J. P. 2012. Equine Laparoscopy: Equipment and Basic Principles. Michigan State University. CHEMICELLTM. 2010. Ferrofluids [Online]. Available: http://www.chemicell.com/home/index.html [Accessed 27/09 2010]. CHEUNG, E., KARAGOZLER, M. E., SUKHO, P., BYUNGKYU, K. & SITTI, M. A new endoscopic microcapsule robot using beetle inspired microfibrillar adhesives. Advanced Intelligent Mechatronics. Proceedings, 2005 IEEE/ASME International Conference on, 24-28 July 2005 2005. 551-557. CHICEA, D., INDREA, E. & CRETU, C. M. 2012. Assesing Fe3O4 nanoparticle size by DLS, XRD and AFM. JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 14, 460-466. CHOMOUCKA, J., DRBOHLAVOVA J FAU - HUSKA, D., HUSKA D FAU - ADAM, V., ADAM V FAU - KIZEK, R., KIZEK R FAU - HUBALEK, J. & HUBALEK, J. 2010. Magnetic nanoparticles and targeted drug delivering. Pharmacol Research, 62, 144-149. CHURCH, J. & DELANEY, C. 2003. Randomized, Controlled Trial of Carbon Dioxide Insufflation During Colonoscopy. Diseases of the Colon & Rectum, 46, 322-326. COMAROW, A. 2002. Tiny holes, big surgery. Minimal surgery hurts less and scars less--but is it right for you? US News World Report, 133, 48-54. CULMER, P., BARRIE, J., HEWSON, R., LEVESLEY, M., MON-WILLIAMS, M., JAYNE, D. & NEVILLE, A. 2012. Reviewing the technological challenges associated with the development of a laparoscopic palpation device. The International Journal of Medical Robotics and Computer Assisted Surgery, 8, 146-159. CULMER PETER, B. J., HEWSON R, LEVESLEY M, MON-WILLIAMS M, JAYNE D, NEVILLE A. 2012. Reviewing the technological challenges associated with the development of a laparoscopic palpation device. The International Journal of Medical Robotics and Computer Assisted Surgery, 8, 146-159. CUSCHIERI, A. 1999. Technology for Minimal Access Surgery. British Medical Journal, 319, 1-6. CUSCHIERI, A. & BERCI, G. 1990. Laparoscopic Biliary Surgery, Oxford, Blackwell Scientific Piblications. DE, S., ROSEN, J., DAGAN, A., HANNAFORD, B., SWANSON, P. & SINANAN, M. 2007. Assessment of Tissue Damage due to Mechanical Stresses. The International Journal of Robotics Research, 26, 1159-1171. DE, S., ROSEN, J., DAGAN, A., SWANSON, P., SINANAN, M. & HANNAFORD, B. Assessment of Tissue Damage due to Mechanical Stresses. Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on, 20-22 Feb. 2006 2006. 823-828. DE VISSER, H. 2003a. Grasping Safely: Instruments for bowel manipulation investigated. Delft University of Technology. DE VISSER, H. 2003b. Grasping Safety Instruments for Bowel Manipulation Investigated. PhD thesis, Delft University of Technology. DERKS, D., LINDNER, A., CRETON, C. & BONN, D. 2003. Cohesive Failure of Thin Layers of Soft Model Adhesives Under Tension. Journal of Applied Physics, 93, 1557-1566. DEZIEL, D. J., MILLIKAN KW FAU - ECONOMOU, S. G., ECONOMOU SG FAU - DOOLAS, A., DOOLAS A FAU - KO, S. T., KO ST FAU - AIRAN, M. C. & AIRAN, M. C. 1993. Complications of laparoscopic cholecystectomy: a national survey of 4,292 hospitals and an analysis of 77,604 cases. American Journal of Surgery, 165, 9-14. DHUMANE, P. W., DIANA M FAU - LEROY, J., LEROY J FAU - MARESCAUX, J. & MARESCAUX, J. 2011. Minimally Invasive Single-Site Surgery for the Digestive System: A Technological Review. Journal of Minimal Access Surgery, 7, 40-51. DILL, T. 2008. Contraindications to Magnetic Resonance Imaging. Heart, 94, 943-948. DIODATO JR, M. D., PROSAD, S. M., KLINGENSMITH, M. E. & DAMIANO JR, R. J. 2004. Robotics in Surgery. Current Problems in Surgery, 41, 752-810. DOMINGUEZ, G., DURAND, L., ROSA, J. D., DANGUISE, E., AROZAMENA, C. & FERRAINA, P. A. 2009. Retraction and triangulation with neodymium magnetic forceps for single-port laparoscopic cholecystectomy. Surgical Endoscopy, 23, 1660-1666. DRILLER, J. & FREI, E. H. 1987. A Review of Medical Applications of Magnet Attraction and Detection. Journal of Medical Engineering & Technology, 11, 271-277. EISNER, T. & ANESHANSLEY, D. J. 2000. Defense by foot adhesion in a beetle. Proceedings of the National Academy of Sciences, 97, 6568-6573. EMAGNETSUK. 2010. Neodymium Magnets [Online]. Available: http://e-magnetsuk.com/magnets/neodymium_magnets/ [Accessed 20. May. 2010. ESTEY, E. P. 2009. Robotic Prostatectomy: The New Standard of Care or A Marketing Success? Canadian Urological Association Journal, 3, 488-490. FALEX TRIBOLOGY. 2014. Modular Universal Surface Tester [Online]. FALEX TRIBOLOGY. Available: http://www.falexint.com/en/equipment. FEDERLE, W., BARNES WJ FAU - BAUMGARTNER, W., BAUMGARTNER W FAU - DRECHSLER, P., DRECHSLER P FAU - SMITH, J. M. & SMITH, J. M. 2006. Wet but not slippery: Boundary friction in tree frog adhesive toe pads. Journal of the Royal Society of Interface, 3, 689-697. FILIPPOV, A., POPOV, V. L. & GORB, S. N. 2011. Shear induced adhesion: Contact mechanics of biological spatula-like attachment devices. Journal of Theoretical Biology, 276, 126-131. FINE SCIENCE TOOLS GMBH. 2014. Fine Science Tools GmbH [Online]. Available: http://www.finescience.de/. FIRGELLI TECHNOLOGIES INC.® 2011. L12 Linear Actuator. FRANCIS, B. A. & HORN, R. G. 2001. Apparatus-specific analysis of fluid adhesion measurements. Journal of Applied Physics, 89, 4167-4174. GALVAO NETO, M., RAMOS, A. & CAMPOS, J. 2009. Single port laparoscopic access surgery. Techniques in Gastrointestinal Endoscopy, 11, 84-93. GAVARA, N. & CHADWICK, R. S. 2010. Noncontact microrheology at acoustic frequencies using frequency-modulated atomic force microscopy. Nature Methods, 7, 650-654. GAY, C. 2002. Stickiness - Some Fundamentals of Adhesion. Integrative and Comparative Biology, 42, 1123-1126. GEBESHUBER, I. C., STACHELBERGER H FAU - DRACK, M. & DRACK, M. 2005. Diatom bionanotribology--biological surfaces in relative motion: their design, friction, adhesion, lubrication and wear. Journal of Nanoscience and Nanotechnology, 5, 79-87. GEIM, A. K., DUBONOS, S. V., GRIGORIEVA, I. V., NOVOSELOV, K. S., ZHUKOV, A. A. & SHAPOVAL, S. Y. 2003. Microfabricated adhesive mimicking gecko foot-hair. Nature Materials, 2, 461-463. GRANT, F. S. & WEST, G. F. 1965. Interpretation Theory in Applied Geophysics, McGraw-Hill Book Co. GREINER, C., CAMPO, A. & ARZT, E. 2007. Adhesion of bioinspired micropatterned surfaces: effects of pillar radius, aspect ratio, and preload. Langmuir, 7, 3495-3502. GRIEVE, D., BARTON, D., CROLLA, D. & BUCKINGHAM, J. 1998. Design of a lightweight automotive brake disc using finite element and Taguchi techniques. J Automobile Eng, 212, 245-254. GUPTA, V., REDDY, N. P. & BATUR, P. Forces in surgical tools: comparison between laparoscopic and surgical forceps. Engineering in Medicine and Biology Society, 1996. Bridging Disciplines for Biomedicine. Proceedings of the 18th Annual International Conference of the IEEE, 31 Oct-3 Nov 1996 1996. 223-224 vol.1. HASHIZUME, M. & TSUGAWA, K. 2004. Robotic Surgery and Cancer: the Present State, Problems and Future Vision. Japanese Journal of Clinical Oncology, 34, 227-237. HATCH, G. P. & STELTER, R. E. 2001. Magnetic design considerations for devices and particles used for biological high-gradient magnetic separation (HGMS) systems. Journal of Magnetism and Magnetic Materials, 225, 262-276. HE, C., HU, Y., YIN, L., TANG, C. & YIN, C. 2010. Effects of particle size and surface charge on cellular uptake and biodistribution of polymeric nanoparticles. Biomaterials, 31, 3657-3666. HEALTH PROTECTION AGENCY 2008. Static Magnetic Fields - Report of the Independent Advisory Group on Non-ionising Radiation. In: DOCUMENTS OF THE HEALTH PROTECTION AGENCY (ed.) Radiation, Chemical and Environmental Hazards. HEIJNSDIJK, E. 2004. Tissue Manipulation in Laparoscopic Surgery. PhD thesis, Delft University of Technology. HIRST MAGNETIC INSTRUMENTS LTD.®. 2004. Gassmeters [Online]. Cornwall. Available: http://www.hirst-magnetics.com/instruments/gauss.shtml [Accessed 07.Oct 2013]. HOPKINS, H. H. & KAPANY, N. S. 1954. A Flexible Fibrescope, using Static Scanning. Nature, 173, 39-41. HORGAN, S. & VANUNO, D. 2004. Robots in laparoscopic surgery. Journal of Laparoscopic & Advanced Surgical Techniques, 11, 415-419. HUBER, G., MANTZ, H., SPOLENAK, R., MECKE, K., JACOBS, K., GORB, S. N. & ARZT, E. 2005. Evidence for capillarity contributions to gecko adhesion from single spatula nanomechanical measurements. Proceedings of the National Academy of Sciences of the United States of America, 102, 16293-16296. HYUN, J. J., CHUN, H. R., CHUN, H. J., JEEN, Y. T., WON BAECK, C., KYUN YU, S., SIK KIM, Y., SIK LEE, H., HO UM, S., WOO LEE, S., HYUN CHOI, J., DUCK KIM, C., SANG RYU, H. & HAI HYUN, J. 2006. Comparison of the characteristics of submucosal injection solutions used in endoscopic mucosal resection. Scandinavian Journal of Gastroenterology, 41, 488-492. JINDAL, U. C. 2012. Material Science and Metallurgy, Dorling Kindersley. JUNG, Y. S. & PARK, D. I. 2013. Submucosal injection solutions for endoscopic mucosal resection and endoscopic submucosal dissection of gastrointestinal neoplasms. Gastrointestinal Intervention, 2, 73-77. KAISER, M., KRUG, J. & ROSE, G. Interventional MRI: Minimal-invasive Surgery under MR guidance. Microwave Symposium Digest (MTT), 2011 IEEE MTT-S International, 5-10 June 2011 2011. 1-4. KALLOO, A. N., SINGH, V. K., JAGANNATH, S. B., NIIYAMA, H., HILL, S. L., VAUGHN, C. A., MAGEE, C. A. & KANTSEVOY, S. V. 2004. Flexible transgastric peritoneoscopy: a novel approach to diagnostic and therapeutic interventions in the peritoneal cavity. Gastrointestinal Endoscopy, 60, 114-117. KANTSEVOY SV, ADLER DG, CONWAY JD, DIEHL DL, FARRAYE FA, KWON R, MAMULA P, RODRIGUEZ S, SHAH RJ, WONG KEE SONG LM & WM., T. 2008. Endoscopic mucosal resection and endoscopic submucosal dissection. Technology Status Evaluation Report. American Society for Gastrointestinal Endoscopy. KEMNER, A. 1999. Experimental evaluation of traumatic properties of laparoscopic dissecting forceps. Delft, The Netherlands: Man-Machine Systems and Control, Delft University of Technology. KUME, M., MIYAZAWA, H., ABE, F., IWASAKI, W., UCHINAMI, H., SHIBATA, S., SATO, T. & YAMAMOTO, Y. 2008a. A newly designed magnet-retracting forceps for laparoscopic cholecystectomy in a swine model. Minimally Invasive Therapy, 17, 251-254. KUME, M., MIYAZAWA, H., IWASAKI, W., ABE, F., UCHINAMI, H. & YAMAMOTO, Y. 2008b. The Use of Magnetic Anchors in the Bowel Lumen for Laparoscopic Anterior Resection of Rectosigmoid Colon in Pigs: with Video. World Journal of Surgery, 32, 2425-2428. LACOMBE, R. 2006. Adhesion measurement methods: theory and practice, Taylor & Francis Group. LAM, A., KAUFMAN, Y., KHONG, S. Y., LIEW, A., FORD, S. & CONDOUS, G. 2009. Dealing with Complications in Laparoscopy. Best Practice & Research Clinical Obstetrics and Gynaecology, 23, 631-646. LEE, H., LEE, B. P. & MESSERSMITH, P. B. 2007. A reversible wet/dry adhesive inspired by mussels and geckos. Nature, 448, 338-341. LENZ, L., DI SENA, V., NAKAO, F. S., ANDRADE, G. P. D., ROHR, M. R. D. S. & FERRARI JR, A. P. 2010. Comparative results of gastric submucosal injection with hydroxypropyl methylcellulose, carboxymethylcellulose and normal saline solution in a porcine model. Arquivos de Gastroenterologia, 47, 184-187. LEVINE, G. N., GOMES AS FAU - ARAI, A. E., ARAI AE FAU - BLUEMKE, D. A., BLUEMKE DA FAU - FLAMM, S. D., FLAMM SD FAU - KANAL, E., KANAL E FAU - MANNING, W. J., MANNING WJ FAU - MARTIN, E. T., MARTIN ET FAU - SMITH, J. M., SMITH JM FAU - WILKE, N., WILKE N FAU - SHELLOCK, F. S. & SHELLOCK, F. S. 2007. Safety of Magnetic Resonance Imaging in Patients with Cardiovascular Devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation by American Heart Association, 116, 2878-2891. LIANG, Y. A., AUTUMN, K., HSIEH, S. T., ZESCH, W., CHAN, W. P., FEARING, R. S., FULL, R. J. & KENNY, T. W. Adhesion force measurements on single gecko setae. Solid-State Sensor and Actuator Workshop, June 4-8 2000 Hilton Head Island, South Carolina. 33-38. LIAO, S.-B., DOURMASHKIN, P. & BELCHER, J. 2004. Introduction to Electricity and Magnetism. MIT OpenCourseWare. LIEN, H.-H., HUANG, C.-C., TAN, L.-I., WANG, P.-C., LIN, H.-Z. & HUANG, C.-S. 2013. RE: Review of Cholecystotomy. LIN, C.-L., LEE, C.-F. & CHIU, W.-Y. 2005. Preparation and properties of poly(acrylic acid) oligomer stabilized superparamagnetic ferrofluid. Journal of Colloid and Interface Science, 291, 411-420. LIN, J. & VALENTINE, M. T. 2012a. High-force NdFeB-based magnetic tweezers device optimized for microrheology experiments. Review of Scientific Instruments, 83, 053905. LIN, J. & VALENTINE, M. T. 2012b. Ring-shaped NdFeB-based magnetic tweezers enables oscillatory microrheology measurements. Applied Physics Letters, 100, 201902-201902-4. LINDNER, A., DERKS, D. & SHELLEY, M. J. 2005. Stretch flow of thin layers of Newtonian liquids: Fingering patterns and lifting forces. Physics of Fluids, 17, 072107-072119. LIPFERT, J., HAO, X. & DEKKER, N. H. 2009. Quantitative Modeling and Optimization of Magnetic Tweezers. Biophysical journal, 96, 5040-5049. LIQUIDS RESEARCH LTD. 2014. Magnetic Fluid [Online]. Available: http://www.liquidsresearch.com/en-GB/products-46.aspx 2010]. LIRA, S. A. & MIRANDA, J. A. 2009a. Adhesion Properties of Chain-Forming Ferrofluids. Physical Review E, 79. LIRA, S. A. & MIRANDA, J. A. 2009b. Field-Controlled Adhesion in Confined Magnetorheological Fluids. Physical Review E, 80, 046313-(1-8). LOBE, T. E. 2003. Pediatric Laparoscopy, LeBonbeur Children's Medical Center, University of Tennessee, USA. LONG, R. & HUI, C.-Y. 2009. The effect of preload on the pull-off force in indentation tests of microfibre arrays. Proceedings of the Royal Society A: Mathematical, Physical and Engineering Science, 465, 961-981. LORENZ, B., KRICK BA FAU - MULAKALURI, N., MULAKALURI N FAU - SMOLYAKOVA, M., SMOLYAKOVA M FAU - DIELUWEIT, S., DIELUWEIT S FAU - SAWYER, W. G., SAWYER WG FAU - PERSSON, B. N. J. & PERSSON, B. N. 2013. Adhesion: Role of Bulk Viscoelasticity and Surface Roughness. Journal of Physics: Condensed Matter, 25, 225004-225020. MAHLE, S., ILG, P. & LIU, M. 2008. Hydrodynamic theory of polydisperse chain-forming ferrofluids. Physical Review E, 77, 016305. MALVERN®. 2014. Zetasizer Nano [Online]. Available: http://www.malvern.com/en/products/product-range/zetasizer-range/default.aspx 2012]. MCGEE, M. F., ROSEN, M. J., MARKS, J., ONDERS, R. P., CHAK, A., FAULX, S., CHEN, V. K. & PONSKY, J. 2006. A Primer on Natural Orifice Transluminal Endoscopic Surgery: Building a New Paradigm. Surgical Innovation, 13, 86-93. MEEKER, D. 2011. Finite Element Method Magnetics (FEMM) [Online]. Available: http://www.femm.info/wiki/HomePage. MENON, C., MURPHY, M., SITTI, M. & LAN, N. 2007. Space Exploration - Towards Bio-inspired Climbing Robots, Vienna, Austria. MERRIFIELD, B. F., WAGH, M. S. & THOMPSON, C. C. 2006. Peroral transgastric organ resection: a feasibility study in pigs. Gastrointestinal Endoscopy, 63, 693-697. MICROMOD PARTIKELTECHNOLOGIE GMBH. 2014. modular designed particles [Online]. Available: http://www.micromod.de/ 2010]. MINTZ, Y., HORGAN S FAU - CULLEN, J., CULLEN J FAU - STUART, D., STUART D FAU - FALOR, E., FALOR E FAU - TALAMINI, M. A. & TALAMINI, M. A. 2008. NOTES: a review of the technical problems encountered and their solutions. Journal of Laparoscopic & Advanced Surgical Techniques, 18, 583-587. MIRANDA, J. A. & OLIVEIRA, R. M. 2004. Adhesion Phenomena in Ferrofluids. Physical Review E, 70, 036311-(1-10). MORSI, H., YONG, K. L. & JEWELL, A. P. 2004. Evaluation of the Taguchi Methods for the Simultaneous Assessment of the Effects of Multiple Variables in the Tumour Microenvironment. Int Semin Surg Oncol, 20, 1-9. MULLER, O., HAHN, D. & LIU, M. 2006. Non-Newtonian behaviour in ferrofluids and magnetization relaxation. Journal of Physics: Condensed Matter, 18, S2623-S2632. MURPHY, M. P., TSO, W., TANZINI, M. & SITTI, M. Waalbot: An Agile Small-Scale Wall Climbing Robot Utilizing Pressure Sensitive Adhesives. Intelligent Robots and Systems, 2006 IEEE/RSJ International Conference on, 9-15 Oct. 2006 2006. 3411-3416. NAJMALDIN, A. & GUILLOU, P. 1998. A Guide to Laparoscopic Surgery, Leeds. NASE, J., LINDNER, A. & CRETON, C. 2008. Pattern Formation during Deformation of a Confined Viscoelastic Layer: From a Viscous Liquid to a Soft Elastic Solid. Physical Review Letters, 101, 074503. NATIONAL INSTRUMENTS®. 2014. NI USB-6008 12-Bit, 10 kS/s Low-Cost Multifunction DAQ [Online]. Available: http://sine.ni.com/nips/cds/view/p/lang/en/nid/201986 [Accessed 28. Sep. 2010. NEDOSEKIN, D. A., SHASHKOV EV FAU - GALANZHA, E. I., GALANZHA EI FAU - HENNINGS, L., HENNINGS L FAU - ZHAROV, V. P. & ZHAROV, V. P. 2010. Photothermal multispectral image cytometry for quantitative histology of nanoparticles and micrometastasis in intact, stained and selectively burned tissues. Cytometry Part A, 77, 1049-1058. NEUMAN, K. C. & NAGY, A. 2008. Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy. Nature Methods, 5, 491-505. NGUYEN, N. T., ROOT J FAU - ZAINABADI, K., ZAINABADI K FAU - SABIO, A., SABIO A FAU - CHALIFOUX, S., CHALIFOUX S FAU - STEVENS, C. M., STEVENS CM FAU - MAVANDADI, S., MAVANDADI S FAU - LONGORIA, M., LONGORIA M FAU - WILSON, S. E. & WILSON, S. E. 2005. Accelerated growth of bariatric surgery with the introduction of minimally invasive surgery. NOVEL INSTRUMENTS FOR MINIMALLY INVASIVE TECHNIQUES. 2010. Novel Instruments For Minimally Invasive Techniques [Online]. Available: http://www.imdi-nimit.nl/index.php?page=artikel&artikel_id=20. ODENBACH, S. 2004. Recent progress in magnetic fluid research. Journal of Physics: Condensed Matter, 16, R1135. OLYMPUS. 2014. Polypectomy, EMR & ESD [Online]. Available: http://www.olympus-europa.com/. OMEGA®. 2013-2014. Omega [Online]. Available: http://www.omega.com/pptst/LCAE.html 2010]. PAI, R. D., FONG, D. G., BUNDGA, M. E., ODZE, R. D., RATTNER, D. W. & THOMPSON, C. C. 2006. Transcolonic endoscopic cholecystectomy: a NOTES survival study in a porcine model (with video). Gastrointestinal Endoscopy, 64, 428-434. PAMME, N. 2006. Magnetism and microfluidics. Lab on a Chip, 6, 24-38. PAMME, N. & MANZ, A. 2004. On-Chip Free-Flow Magnetophoresis: Continuous Flow Separation of Magnetic Particles and Agglomerates. Analytical Chemistry, 76, 7250-7256. PARK, S., BERGS, R. A., EBERHART, R., BAKER, L., FERNANDEZ, R. & CADEDDU, J. A. 2007. Trocar-less Instrumentation for Laparoscopy Magnetic Positioning of Intra-abdominal Camera and Retractor. Annals of Surgery, 245, 379-384. PEARL, J. P. & PONSKY, J. L. 2007. Natural orifice transluminal endoscopic surgery: Past, present and future. J Min Access Surg 3, 43-46. PETIT, M., LEBOUC, A. K., AVENAS, Y., TAWK, M. & ARTEGA, E. 2011. Calculation and analysis of local magnetic forces in ferrofluids. Przegląd Elektrotechniczny, 87, 115-119. PHILOSOPHE, R. 2003. Avoiding Complications of Laparoscopic Surgery. Sexuality, Reproduction & Menopause, 1, 30-39. PIZZI, A. & MITTAL, K. L. 2003. Handbook of Adhesive Technology, Revised and Expanded, Taylor & Francis. POCIUS, A. V. 2002. Adhesion and Adhesives Technology: An Introduction, Hanser. POIVET, S. & ET AL. 2003. Cavitation-induced force transition in confined viscous liquids under traction. EPL (Europhysics Letters), 62, 244. POIVET, S., NALLET, F., GAY, C., TEISSEIRE, J. & FABRE, P. 2004. Force response of a viscous liquid in a probe-tack geometry: Fingering versus cavitation. The European Physical Journal E: Soft Matter and Biological Physics, 15, 97-116. PUANGMALI, P., ALTHOEFER, K., SENEVIRATNE, L. D., MURPHY, D. & DASGUPTA, P. 2008. State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery. Sensors Journal, IEEE, 8, 371-381. RABENOROSOA, K., CLEVY, C., LUTZ, P., GAUTHIER, M. & ROUGEOT, P. 2009. Measurement of pull-off force for planar contact at the microscale. Micro & Nano Letters, 4. RAMAN, J. D., SCOTT, D. J. & CADEDDU, J. A. 2009. Role of Magnetic Anchors During Laparoendoscopic Single Site Surgery and NOTES. JOURNAL OF ENDOUROLOGY, 23, 781-786. RAMARAJ, R., SUGUMARAN, A., KHAN, H., MATHIALAHAN, T. & GEORGE, P. 2011. Comparison of carbon dioxide (CO2) to air insufflation in colonoscopy. Gut, 60, A200. RENTSCHLER, M., DUMPERT, J., PLATT, S., FARRITOR, S. & OLEYNIKOV, D. 2007. Natural orifice surgery with an endoluminal mobile robot. Surgical Endoscopy, 21, 1212-1215. RENTSCHLER, M. E., DUMPERT, J., PLATT, S. R., OLEYNIKOV, D., FARRITOR, S. M. & IAGNEMMA, K. Mobile in vivo biopsy robot. Robotics and Automation, 2006. ICRA 2006. Proceedings 2006 IEEE International Conference on, 15-19 May 2006 2006. 4155-4160. RODRIGUES, S. P., HOREMAN T FAU - DANKELMAN, J., DANKELMAN J FAU - VAN DEN DOBBELSTEEN, J. J., VAN DEN DOBBELSTEEN JJ FAU - JANSEN, F.-W. & JANSEN, F. W. 2012. Suturing Intraabdominal Organs: When Do We Cause Tissue Damage? Surgical Endoscopy, 26, 1005-1009. ROSHAN, R., JAYNE, D. G., LISKIEWICZ, T., TAYLOR, G. W., GASKELL, P. H., CHEN, L., MONTELLANO-LOPEZ, A., MORINA, A. & NEVILLE, A. 2011. Effect of tribological factors on wet adhesion of a microstructured surface to peritoneal tissue. Acta Biomaterialia, 7, 4007-4017. RYOU, M. & THOMPSON, C. 2009. Magnetic retraction in natural-orifice transluminal endoscopic surgery (NOTES): addressing the problem of traction and countertraction. Endoscopy, 41, 143-148. SANGBAE, K., SPENKO, M., TRUJILLO, S., HEYNEMAN, B., SANTOS, D. & CUTKOSKY, M. R. 2008. Smooth Vertical Surface Climbing With Directional Adhesion. Robotics, IEEE Transactions on, 24, 65-74. SCHLAGER, A., KHALAILEH, A., SHUSSMAN, N., ELAZARY, R., KEIDAR, A., PIKARSKY, A., BEN-SHUSHAN, A., SHIBOLET, O., HORGAN, S., TALAMINI, M., ZAMIR, G., RIVKIND, A. & MINTZ, Y. 2010. Providing more through less: current methods of retraction in SIMIS and NOTES cholecystectomy. Surgical Endoscopy, 24, 1542-1546. SCHLIEMANN, H. & GOODMAN, S. M. 2011. A new study on the structure and function of the adhesive organs of the Old World sucker-footed bat (Myzopoda: Myzopodidae) of Madagascar. Verhandlungen des Naturwissenschaftlichen Vereins in Hamburg, 46, 313-330. SCOTT, D. J., TANG, S.-J., FERNANDEZ, R., BERGS, R., GOOVA, M. T., ZELTSER, I., KEHDY, F. J. & CADEDDU, J. A. 2007. Completely transvaginal NOTES cholecystectomy using magnetically anchored instruments. Surgical Endoscopy, 21, 2308-2316. SHAIKH, S. N. & THOMPSON, C. 2010a. Natural Orifice Translumenal Surgery: Flexible Platform Review. World Journal of Gastrointestinal Surgery, 2, 210-216. SHAIKH, S. N. & THOMPSON, C. C. 2010b. Natural orifice translumenal surgery: Flexible platform review. World Journal of Gastrointestinal Surgery, 2, 210-216. SHANG, J., PAYNE, C. J., CLARK, J., NOONAN, D. P., KWOK, K. W., DARZI, A. & YANG, G. Z. 2012. Design of a Multitasking Robotic Platform with Flexible Arms and Articulated Head for Minimally Invasive Surgery. 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems. SHAO, H., BACHUS, K. N. & STEWART, R. J. 2009. A Water-Borne Adhesive Modeled after the Sandcastle Glue of P. californica. Journal of Macromolecular Bioscience, 9, 464-471. SHAO, H. & STEWART, R. J. 2010. Biomimetic Underwater Adhesives with Environmentally Triggered Setting Mechanisms. Advanced Materials, 22, 729-733. SHINKAI, M. 2002. Functional magnetic particles for medical application. Journal of Bioscience and Bioengineering, 94, 606-613. SHLIOMIS, M. 2003. Ferrohydrodynamics: Retrospective and Issues. In: ODENBACH, S. (ed.) Ferrofluids. Springer Berlin Heidelberg. SILVA, A., SILVA-FREITAS, É., CARVALHO, J., PONTES, T., ARAÚJO-NETO, R., SILVA, K., CARRIÇO, A. & EGITO, E. 2012. Magnetic Particles in Biotechnology: From Drug Targeting to Tissue Engineering. SLOUGH, J. T. & MILLER, K. E. 2001. Small, high frequency probe for internal magnetic field measurements in high temperature plasmas. Review of Scientific Instruments, 72, 417-420. SNEDDON, I. N. 1965. The relation between load and penetration in the axisymmetric boussinesq problem for a punch of arbitrary profile. International Journal of Engineering Science, 3, 47-57. SOETIKNO, R. M., GOTODA, T., NAKANISHI, Y. & SOEHENDRA, N. 2003. Endoscopic mucosal resection. Gastrointestinal Endoscopy, 57, 567-579. SOUZA, G. R., MOLINA, J. R., RAPHAEL, R. M., OZAWA, M. G., STARK, D. J., LEVIN, C. S., BRONK, L. F., ANANTA, J. S., MANDELIN, J., GEORGESCU, M.-M., BANKSON, J. A., GELOVANI, J. G., KILLIAN, T. C., ARAP, W. & PASQUALINI, R. 2010. Three-dimensional tissue culture based on magnetic cell levitation. Nat Nano, 5, 291-296. STARK, A. Y., BADGE, I., WUCINICH, N. A., SULLIVAN, T. W., NIEWIAROWSKI, P. H. & DHINOJWALA, A. 2013. Surface wettability plays a significant role in gecko adhesion underwater. Proceedings of the National Academy of Sciences, 110, 6340-6345. STYLE, R. W., HYLAND, C., BOLTYANSKIY, R., WETTLAUFER, J. S. & DUFRESNE, E. R. 2013. Surface Tension and Contact with Soft Elastic Solids. Nat Commun, 4, 2728. SUMIYAMA, K., GOSTOUT, C. J., RAJAN, E., BAKKEN, T. A., DETERS, J. L., KNIPSCHIELD, M. A., HAWES, R. H., KALLOO, A. N., PASRICHA, P. J., CHUNG, S., KANTSEVOY, S. V. & COTTON, P. B. 2006. Pilot study of the porcine uterine horn as an in vivo appendicitis model for development of endoscopic transgastric appendectomy. Gastrointestinal Endoscopy, 64, 808-812. TAGUCHI, G. 1993. Taguchi on Robust Technology Development: Bringing Quality Engineering Upstream, ASME Press. TAYLOR, G., LISKIEWICZ, T., NEVILLE, A., MORINA, A. & GASKELL, P. H. 2009. Providing Adhesion for a Miniature Mobile Intra-Abdominal Device Based on Biomimetic Principles. 3rd Vienna International Conference NANO-TECHNOLOGY. Vienna. TAYLOR, G. W. & JAYNE, D. G. 2007. Robotic Applications in Abdominal Surgery: Their Limitations and Future Developments. The International Journal of Medical Robotics and Computer Assisted Surgery, 3, 3-9. TAYLOR, G. W., NEVILLE, A., JAYNE, D. G., ROSHAN, R., LISKIEWICZ, T., MORINA, A. & GASKELL, P. H. 2010. Wet adhesion for a miniature mobile intra-abdominal device based on biomimetic principles. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 224, 1473-1485. THE HEALTH AND SOCIAL CARE INFORMATION CENTRE 2012. National Bowel Cancer Audit (NBCA) Annual Report. NBCA. THE HEALTH AND SOCIAL CARE INFORMATION CENTRE 2013. National Bowel Cancer Audit (NBCA) Annual Report. TIETZE, R., JURGONS, R., LYER, S., SCHREIBER, E., WIEKHORST, F., EBERBECK, D., RICHTER, H., STEINHOFF, U., TRAHMS, L. & ALEXIOU, C. 2009. Quantification of drug-loaded magnetic nanoparticles in rabbit liver and tumor after in vivo administration. Journal of Magnetism and Magnetic Materials, 321, 1465-1468. TIETZE, R., RAHN H FAU - LYER, S., LYER S FAU - SCHREIBER, E., SCHREIBER E FAU - MANN, J., MANN J FAU - ODENBACH, S., ODENBACH S FAU - ALEXIOU, C. & ALEXIOU, C. 2011. Visualization of superparamagnetic nanoparticles in vascular tissue using XmuCT and histology. Histochen and Cell Biology, 135, 153-158. TOLEDO, L., GOSSOT D FAU - FRITSCH, S., FRITSCH S FAU - REVILLON, Y., REVILLON Y FAU - REBOULET, C. & REBOULET, C. 1999. Study of Sustained Forces and The Working Space of Endoscopic Surgery Instruments. Annales de Chirurgie, 53, 587-897. TORTORA, G., SALERNO, M., RANZANI, T., TOGNARELLI, S., DARIO, P. & MENCIASSI, A. A modular magnetic platform for natural orifice transluminal endoscopic surgery. Annual International Conference of the IEEE EMBS, 3 - 7 July 2013 2013 Osaka, Japan. 6265-6268. TRAN CAO, H. S., LOPEZ, N., CHANG, D. C. & ET AL. 2014. Improved perioperative outcomes with minimally invasive distal pancreatectomy: Results from a population-based analysis. JAMA Surgery, 149, 237-243. TRIEF & OLK. 2013. Schematic of Laparoscopic Cholecystectomic Surgery [Online]. Available: http://www.laparoscopicsurgeryinfo.com/images/laparoscopic1.jpg 2013]. UEMATSU, D., AKIYAMA, G., MAGISHI, A., NAKAMURA, J. & HOTTA, K. 2010. Single-Access Laparoscopic Left and Right Hemicolectomy Combined With Extracorporeal Magnetic Retraction. Diseases of the Colon & Rectum, 53, 944-948. VAN DER VOORT, M., HEIJNSDIJK, E. A. M. & GOUMA, D. J. 2004. Bowel Injury as a Complication of Laparoscopy. British Journal of Surgery, 91, 1253-1258. VÉKÁS, L. 2008. Ferrofluids and Magnetorheological Fluids. Advances in Science and Technology, 54, 127-136. VIGNAUD, A., MAÎTRE, X., GUILLOT, G., DURAND, E., DE ROCHEFORT, L., ROBERT, P., VIVÈS, V., SANTUS, R. & DARRASSE, L. 2005. Magnetic susceptibility matching at the air–tissue interface in rat lung by using a superparamagnetic intravascular contrast agent: Influence on transverse relaxation time of hyperpolarized helium-3. Magnetic Resonance in Medicine, 54, 28-33. VONCK, D. 2013a. The Feasibility of Vacuum Technique in Minimal Invasive Surgery. PhD Thesis, Delft University of Technology. VONCK, D. 2013b. The feasibility of vacuum technique in minimal invasive surgery: Improving the patient safety through instrument design. Delft University of Technology. VONCK, D., GOOSSENS, R. H. M., EIJK, D. J., HINGH, I. H. J. T. & JAKIMOWICZ, J. J. 2010. Vacuum grasping as a manipulation technique for minimally invasive surgery. Surgical Endoscopy, 24, 2418-2423. VONCK, D., JAKIMOWICZ, J. J., LOPUHAÄ, H. P. & GOOSSENS, R. 2011. Grasping soft tissue by means of vacuum technique. Medical Engineering & Physics. VONCK, D., JAKIMOWICZ, J. J., LOPUHAÄ, H. P. & GOOSSENS, R. H. M. 2012. Grasping soft tissue by means of vacuum technique. Medical Engineering & Physics, 34, 1088-1094. WAGH, M. S., MERRIFIELD, B. F. & THOMPSON, C. C. 2006. Survival studies after endoscopic transgastric oophorectomy and tubectomy in a porcine model. Gastrointestinal Endoscopy, 63, 473-478. WANG, Y., WERTHEIM, D. F., JONES, A. S. & COOMBES, A. G. A. 2010a. Micro-CT in drug delivery. European Journal of Pharmaceutics and Biopharmaceutics, 74, 41-49. WANG, Z., BROWN, A. W., BROWN, S. I., WANG, L., ANDRE, P., FLORENCE, G. J. & CUSCHIERI, A. Intra-luminal injection of ferro-fluid for magnetic bowel retraction in minimal access surgery. Mechatronics and Embedded Systems and Applications (MESA), 2010 IEEE/ASME International Conference on, 15-17 July 2010 2010b. 168-173. WANG, Z., SCHMIDT, A., BROWN, S. I., BROWN, A., MCLEAN, D., FLORENCE, G. J., ANDRE, P. & CUSCHIERI, A. 2012. Design and Evaluation of Permanent Magnet-Based Probe Having Adjustable Magnetic Force for Bowel Retraction in Laparoscopic Surgery. Society of American Gastrointestinal and Endoscopic Surgeons (SAGES). San Diego, The USA. WANG, Z., WANG, L., BROWN, S. I., FRANK, T. G. & CUSCHIERI, A. 2009. Ferromagnetization of Target Tissues by Interstitial Injection of Ferrofluid: Formulation and Evidence of Efficacy for Magnetic Retraction. IEEE Transactions on Biomedical Engineering, 56, 2244-2252. WANG, Z., WANG, L., TANG, B., FRANK, T., BROWN, S. & CUSCHIERI, A. 2008. Retraction by Surface Ferromagnetisation of Target Tissues: Preliminary Studies on Feasibility of Magnetic Retraction for Endoscopic Surgery. Surgical Endoscopy, 22, 1838-1844. WÉBER, G., LANTOS, J., BORSICZKY, B., FERENCZ, A., JANCSÓ, G., FERENCZ, S., HORVÁTH, S., BAHRI, H. H., TAKÁCS, I. & BALATONYI, B. 2008. Basic Surgical Techniques, University of Pécs, Medical School. WESTEBRING-VAN DER PUTTEN, E. P. 2011. A Sense of Touch in Laparoscopy: Using Augmented Haptic Feedback to Improve Grasp Control. PhD Thesis, Delft University of Technology. YAMAUCHI, Y., YAMASHITA, J., MORIKAWA, O., HASHIMOTO, R., MOCHIMARU, M., FUKUI, Y., UNO, H. & YOKOYAMA, K. 2002. Surgical Skill Evaluation by Force Data for Endoscopic Sinus Surgery Training System. In: DOHI, T. & KIKINIS, R. (eds.) Medical Image Computing and Computer-Assisted Intervention — MICCAI 2002. Springer Berlin Heidelberg. ZABER TECHNOLOGIES INC.®. 2014. Zaber Technologies Inc. [Online]. Available: http://www.zaber.com/products/product_detail.php?detail=T-LSR075B#tabs 2013]. ZELTSER, I. S., BERGS, R., FERNANDEZ, R., BAKER, L., EBERHART, R. & CADEDDU, J. A. 2007. Single Trocar Laparoscopic Nephrectomy Using Magnetic Anchoring and Guidance System in the Porcine Model. The Journal of Urology, 178, 288-291. ZELTSER, I. S. & CADEDDU, J. A. 2008. A Novel Magnetic Anchoring and Guidance System to Facilitate Single Trocar Laparoscopic Nephrectomy. Current Urology Reports, 9, 62-64."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.644771"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/8569/1/Yu-Sheng%20Lin_PhD%20Thesis_Final.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Nano-scale Iron-Oxide ferrofluids exhibit a special property, ‘superparamagnetism’, that induces an attractive force toward an external magnetic field. The aim of this project is to investigate the use of ferrofluids for tissue retraction during Minimally Access Surgery (MAS). In the in-vivo porcine experiments, 0.3 ml of ferrofluid (200 mg/ml concentration) containing 10 nm particles is injected subserosally into the small bowel, respectively. A 0.6 T magnetic field is created using a combination of 10 mm and 20 mm diameter Neodymium Iron Boron magnets. The vertical retraction distance is measured up to 80 mm and video-recorded. The results demonstrate the capacity of ferrofluid to facilitate the tissue manipulation and analysis of the migration of the particles within the tissue using micro computed tomography (CT). A theoretical model developed to validate the experimental results is also beneficial for predicting retraction force. In conclusion, this feasibility study provides a protocol for systematically using small volumes of ferrofluid, without the need to mechanically grasp the tissue."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Tissue manipulation using nano-particles ferrofluids for minimal access surgical applications"]}]}],"canonical_facts":{"dc:contributor.advisor":["Neville , Anne","Liskiewicz , Tomasz","Roshan, Rupesh"],"dc:creator":["Lin, Yu-Sheng"],"dc:date":["2014-09"],"dc:date.issued":["2014-09"],"dc:description.abstract":["Nano-scale Iron-Oxide ferrofluids exhibit a special property, ‘superparamagnetism’, that induces an attractive force toward an external magnetic field. The aim of this project is to investigate the use of ferrofluids for tissue retraction during Minimally Access Surgery (MAS). In the in-vivo porcine experiments, 0.3 ml of ferrofluid (200 mg/ml concentration) containing 10 nm particles is injected subserosally into the small bowel, respectively. A 0.6 T magnetic field is created using a combination of 10 mm and 20 mm diameter Neodymium Iron Boron magnets. The vertical retraction distance is measured up to 80 mm and video-recorded. The results demonstrate the capacity of ferrofluid to facilitate the tissue manipulation and analysis of the migration of the particles within the tissue using micro computed tomography (CT). A theoretical model developed to validate the experimental results is also beneficial for predicting retraction force. In conclusion, this feasibility study provides a protocol for systematically using small volumes of ferrofluid, without the need to mechanically grasp the tissue."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.644771"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/8569/1/Yu-Sheng%20Lin_PhD%20Thesis_Final.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Faculty of Engineering (Leeds)","School of Mechanical Engineering (Leeds)","Institute of Engineering Thermofluids, Surfaces & Interfaces (iETSI) (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/8569/"],"dc:relation.references":["ACHANTA, S. C. 2008. Investigation of Friction from Nano to Macro Force Scale Under Reciprocating Sliding Conditions. Degree of Doctor, Katholieke Universiteit Leuven. AL KHABURI, J. A. J. 2010. Pressure Mapping of Medical Compression Bandages Used for Venous Leg Ulcer Treatment. PhD, University of Leeds. ALASWAD, F. D. 2013. Treatment Options of Laparoscopic Complications. Journal of the American Society of Abdominal Surgeons. AOYAMA, K., TAKENAKA I FAU - SATA, T., SATA T FAU - SHIGEMATSU, A. & SHIGEMATSU, A. 1996. Use of the Fibrescope-Video Camera System for Difficult Tracheal Intubation. British Journal of Anaesthesia, 77, 662-664. AUSTIN, R. C. 2009. Natural orifice translumenal endoscopic surgery (NOTES) - scar free or scary? Ann R Coll Surg Engl., 91, 192-194. AUTUMN, K. & PEATTIE, A. M. 2002. Mechanisms of Adhesion in Geckos. Integrative and Comparative Biology, 42, 1081-1090. BAILEY, L. O., LIPPIATT S FAU - BIANCANELLO, F. S., BIANCANELLO FS FAU - RIDDER, S. D., RIDDER SD FAU - WASHBURN, N. R. & WASHBURN, N. R. 2005. The Quantification of Cellular Viability and Inflammatory Response to Stainless Steel Alloys. Biomaterials, 26, 5296-5302. BALLANTYNE, G. H. 2002. The pitfalls of laparoscopic surgery: challenges for robotics and telerobotic surgery. Surgical Laparoscopy Endoscopy Percutaneous Techniques, 12, 1-5. BANKS, W. H. & MILL, C. C. 1953. Tacky Adhesion - A Preliminary Study. Journal of Colloid and Interface Science, 8, 137-147. BEST, S. L., BERGS, R., GEDEON, M., PARAMO, J., FERNANDEZ, R., CADEDDU, J. A. & SCOTT, D. J. 2011. Maximizing coupling strength of magnetically anchored surgical instruments: how thick can we go? Surgical Endoscopy, 25, 153-159. BEST, S. L. & CADEDDU, J. A. 2010. Use of Magnetic Anchoring and Guidance Systems to Facilitate Single Trocar Laparoscopy. Current Urology Reports, 11, 29-32. BISHOFF, J. T., ALLAF ME FAU - KIRKELS, W., KIRKELS W FAU - MOORE, R. G., MOORE RG FAU - KAVOUSSI, L. R., KAVOUSSI LR FAU - SCHRODER, F. & SCHRODER, F. 1999a. Laparoscopic bowel injury: incidence and clinical presentation. The Journal of Urology, 161, 887-890. BISHOFF, J. T., ALLAF, M. E., KIRKELS, W., MOORE, R. G., KAVOUSSI, L. R. & SCHRODER, F. 1999b. Laparoscopic Bowel Injury: Incidence And Clinical Presentation. The Journal of Urology, 161, 887-890. BOROS, M., RŐTH, E., LÁZÁR, G. & GAÁL, C. 2006. Surgical Techniques Textbook for medical students, University of Szeged. BRETTHAUER, M., HOFF GS FAU - THIIS-EVENSEN, E., THIIS-EVENSEN E FAU - HUPPERTZ-HAUSS, G., HUPPERTZ-HAUSS G FAU - SKOVLUND, E. & SKOVLUND, E. 2003. Air and Carbon Dioxide Volumes Insufflated During Colonoscopy. Gastrointestinal Endoscopy, 58, 203-206. BRETTHAUER, M., LYNGE AB FAU - THIIS-EVENSEN, E., THIIS-EVENSEN E FAU - HOFF, G., HOFF G FAU - FAUSA, O., FAUSA O FAU - AABAKKEN, L. & AABAKKEN, L. 2005. Carbon Dioxide Insufflation in Colonoscopy: Safe and Effective in Sedated Patients. Journal of Endoscopy, 37, 706-709. BRETTHAUER, M., SEIP B FAU - AASEN, S., AASEN S FAU - KORDAL, M., KORDAL M FAU - HOFF, G., HOFF G FAU - AABAKKEN, L. & AABAKKEN, L. 2007. Carbon Dioxide Insufflation for More Comfortable Endoscopic Retrograde Cholangiopancreatography: A Randomized, Controlled, Double-Blind Trial. Journal of Endoscopy, 39, 58-64. BROWN, T. H. & IRVING, M. H. 1995. Introduction to Minimal Access Surgery, BMJ Publishing Group. CADEDDU, J., FERNANDEZ, R., DESAI, M., BERGS, R., TRACY, C., TANG, S.-J., RAO, P., DESAI, M. & SCOTT, D. 2009. Novel magnetically guided intra-abdominal camera to facilitate laparoendoscopic single-site surgery: initial human experience. Surgical Endoscopy, 23, 1894-1899. CANTILLON, P. J., BRENNAN, P. J., TUGWELL, J., O’DONOGHUE, K. & CAHILL, R. A. Electropermanent Magnets for Transabdominal Anchoring. 21st International Congress of the European Association for Endoscopic Surgery (EAES), 2013 Vienna, Austria. CARON, J. P. 2012. Equine Laparoscopy: Equipment and Basic Principles. Michigan State University. CHEMICELLTM. 2010. Ferrofluids [Online]. Available: http://www.chemicell.com/home/index.html [Accessed 27/09 2010]. CHEUNG, E., KARAGOZLER, M. E., SUKHO, P., BYUNGKYU, K. & SITTI, M. A new endoscopic microcapsule robot using beetle inspired microfibrillar adhesives. Advanced Intelligent Mechatronics. Proceedings, 2005 IEEE/ASME International Conference on, 24-28 July 2005 2005. 551-557. CHICEA, D., INDREA, E. & CRETU, C. M. 2012. Assesing Fe3O4 nanoparticle size by DLS, XRD and AFM. JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 14, 460-466. CHOMOUCKA, J., DRBOHLAVOVA J FAU - HUSKA, D., HUSKA D FAU - ADAM, V., ADAM V FAU - KIZEK, R., KIZEK R FAU - HUBALEK, J. & HUBALEK, J. 2010. Magnetic nanoparticles and targeted drug delivering. Pharmacol Research, 62, 144-149. CHURCH, J. & DELANEY, C. 2003. Randomized, Controlled Trial of Carbon Dioxide Insufflation During Colonoscopy. Diseases of the Colon & Rectum, 46, 322-326. COMAROW, A. 2002. Tiny holes, big surgery. Minimal surgery hurts less and scars less--but is it right for you? US News World Report, 133, 48-54. CULMER, P., BARRIE, J., HEWSON, R., LEVESLEY, M., MON-WILLIAMS, M., JAYNE, D. & NEVILLE, A. 2012. Reviewing the technological challenges associated with the development of a laparoscopic palpation device. The International Journal of Medical Robotics and Computer Assisted Surgery, 8, 146-159. CULMER PETER, B. J., HEWSON R, LEVESLEY M, MON-WILLIAMS M, JAYNE D, NEVILLE A. 2012. Reviewing the technological challenges associated with the development of a laparoscopic palpation device. The International Journal of Medical Robotics and Computer Assisted Surgery, 8, 146-159. CUSCHIERI, A. 1999. Technology for Minimal Access Surgery. British Medical Journal, 319, 1-6. CUSCHIERI, A. & BERCI, G. 1990. Laparoscopic Biliary Surgery, Oxford, Blackwell Scientific Piblications. DE, S., ROSEN, J., DAGAN, A., HANNAFORD, B., SWANSON, P. & SINANAN, M. 2007. Assessment of Tissue Damage due to Mechanical Stresses. The International Journal of Robotics Research, 26, 1159-1171. DE, S., ROSEN, J., DAGAN, A., SWANSON, P., SINANAN, M. & HANNAFORD, B. Assessment of Tissue Damage due to Mechanical Stresses. Biomedical Robotics and Biomechatronics, 2006. BioRob 2006. The First IEEE/RAS-EMBS International Conference on, 20-22 Feb. 2006 2006. 823-828. DE VISSER, H. 2003a. Grasping Safely: Instruments for bowel manipulation investigated. Delft University of Technology. DE VISSER, H. 2003b. Grasping Safety Instruments for Bowel Manipulation Investigated. PhD thesis, Delft University of Technology. DERKS, D., LINDNER, A., CRETON, C. & BONN, D. 2003. Cohesive Failure of Thin Layers of Soft Model Adhesives Under Tension. Journal of Applied Physics, 93, 1557-1566. DEZIEL, D. J., MILLIKAN KW FAU - ECONOMOU, S. G., ECONOMOU SG FAU - DOOLAS, A., DOOLAS A FAU - KO, S. T., KO ST FAU - AIRAN, M. C. & AIRAN, M. C. 1993. Complications of laparoscopic cholecystectomy: a national survey of 4,292 hospitals and an analysis of 77,604 cases. American Journal of Surgery, 165, 9-14. DHUMANE, P. W., DIANA M FAU - LEROY, J., LEROY J FAU - MARESCAUX, J. & MARESCAUX, J. 2011. Minimally Invasive Single-Site Surgery for the Digestive System: A Technological Review. Journal of Minimal Access Surgery, 7, 40-51. DILL, T. 2008. Contraindications to Magnetic Resonance Imaging. Heart, 94, 943-948. DIODATO JR, M. D., PROSAD, S. M., KLINGENSMITH, M. E. & DAMIANO JR, R. J. 2004. Robotics in Surgery. Current Problems in Surgery, 41, 752-810. DOMINGUEZ, G., DURAND, L., ROSA, J. D., DANGUISE, E., AROZAMENA, C. & FERRAINA, P. A. 2009. Retraction and triangulation with neodymium magnetic forceps for single-port laparoscopic cholecystectomy. Surgical Endoscopy, 23, 1660-1666. DRILLER, J. & FREI, E. H. 1987. A Review of Medical Applications of Magnet Attraction and Detection. Journal of Medical Engineering & Technology, 11, 271-277. EISNER, T. & ANESHANSLEY, D. J. 2000. Defense by foot adhesion in a beetle. Proceedings of the National Academy of Sciences, 97, 6568-6573. EMAGNETSUK. 2010. Neodymium Magnets [Online]. Available: http://e-magnetsuk.com/magnets/neodymium_magnets/ [Accessed 20. May. 2010. ESTEY, E. P. 2009. Robotic Prostatectomy: The New Standard of Care or A Marketing Success? Canadian Urological Association Journal, 3, 488-490. FALEX TRIBOLOGY. 2014. Modular Universal Surface Tester [Online]. FALEX TRIBOLOGY. Available: http://www.falexint.com/en/equipment. FEDERLE, W., BARNES WJ FAU - BAUMGARTNER, W., BAUMGARTNER W FAU - DRECHSLER, P., DRECHSLER P FAU - SMITH, J. M. & SMITH, J. M. 2006. Wet but not slippery: Boundary friction in tree frog adhesive toe pads. Journal of the Royal Society of Interface, 3, 689-697. FILIPPOV, A., POPOV, V. L. & GORB, S. N. 2011. Shear induced adhesion: Contact mechanics of biological spatula-like attachment devices. Journal of Theoretical Biology, 276, 126-131. FINE SCIENCE TOOLS GMBH. 2014. Fine Science Tools GmbH [Online]. Available: http://www.finescience.de/. FIRGELLI TECHNOLOGIES INC.® 2011. L12 Linear Actuator. FRANCIS, B. A. & HORN, R. G. 2001. Apparatus-specific analysis of fluid adhesion measurements. Journal of Applied Physics, 89, 4167-4174. GALVAO NETO, M., RAMOS, A. & CAMPOS, J. 2009. Single port laparoscopic access surgery. Techniques in Gastrointestinal Endoscopy, 11, 84-93. GAVARA, N. & CHADWICK, R. S. 2010. Noncontact microrheology at acoustic frequencies using frequency-modulated atomic force microscopy. Nature Methods, 7, 650-654. GAY, C. 2002. Stickiness - Some Fundamentals of Adhesion. Integrative and Comparative Biology, 42, 1123-1126. GEBESHUBER, I. C., STACHELBERGER H FAU - DRACK, M. & DRACK, M. 2005. Diatom bionanotribology--biological surfaces in relative motion: their design, friction, adhesion, lubrication and wear. Journal of Nanoscience and Nanotechnology, 5, 79-87. GEIM, A. K., DUBONOS, S. V., GRIGORIEVA, I. V., NOVOSELOV, K. S., ZHUKOV, A. A. & SHAPOVAL, S. Y. 2003. Microfabricated adhesive mimicking gecko foot-hair. Nature Materials, 2, 461-463. GRANT, F. S. & WEST, G. F. 1965. Interpretation Theory in Applied Geophysics, McGraw-Hill Book Co. GREINER, C., CAMPO, A. & ARZT, E. 2007. Adhesion of bioinspired micropatterned surfaces: effects of pillar radius, aspect ratio, and preload. Langmuir, 7, 3495-3502. GRIEVE, D., BARTON, D., CROLLA, D. & BUCKINGHAM, J. 1998. Design of a lightweight automotive brake disc using finite element and Taguchi techniques. J Automobile Eng, 212, 245-254. GUPTA, V., REDDY, N. P. & BATUR, P. Forces in surgical tools: comparison between laparoscopic and surgical forceps. Engineering in Medicine and Biology Society, 1996. Bridging Disciplines for Biomedicine. Proceedings of the 18th Annual International Conference of the IEEE, 31 Oct-3 Nov 1996 1996. 223-224 vol.1. HASHIZUME, M. & TSUGAWA, K. 2004. Robotic Surgery and Cancer: the Present State, Problems and Future Vision. Japanese Journal of Clinical Oncology, 34, 227-237. HATCH, G. P. & STELTER, R. E. 2001. Magnetic design considerations for devices and particles used for biological high-gradient magnetic separation (HGMS) systems. Journal of Magnetism and Magnetic Materials, 225, 262-276. HE, C., HU, Y., YIN, L., TANG, C. & YIN, C. 2010. Effects of particle size and surface charge on cellular uptake and biodistribution of polymeric nanoparticles. Biomaterials, 31, 3657-3666. HEALTH PROTECTION AGENCY 2008. Static Magnetic Fields - Report of the Independent Advisory Group on Non-ionising Radiation. In: DOCUMENTS OF THE HEALTH PROTECTION AGENCY (ed.) Radiation, Chemical and Environmental Hazards. HEIJNSDIJK, E. 2004. Tissue Manipulation in Laparoscopic Surgery. PhD thesis, Delft University of Technology. HIRST MAGNETIC INSTRUMENTS LTD.®. 2004. Gassmeters [Online]. Cornwall. Available: http://www.hirst-magnetics.com/instruments/gauss.shtml [Accessed 07.Oct 2013]. HOPKINS, H. H. & KAPANY, N. S. 1954. A Flexible Fibrescope, using Static Scanning. Nature, 173, 39-41. HORGAN, S. & VANUNO, D. 2004. Robots in laparoscopic surgery. Journal of Laparoscopic & Advanced Surgical Techniques, 11, 415-419. HUBER, G., MANTZ, H., SPOLENAK, R., MECKE, K., JACOBS, K., GORB, S. N. & ARZT, E. 2005. Evidence for capillarity contributions to gecko adhesion from single spatula nanomechanical measurements. Proceedings of the National Academy of Sciences of the United States of America, 102, 16293-16296. HYUN, J. J., CHUN, H. R., CHUN, H. J., JEEN, Y. T., WON BAECK, C., KYUN YU, S., SIK KIM, Y., SIK LEE, H., HO UM, S., WOO LEE, S., HYUN CHOI, J., DUCK KIM, C., SANG RYU, H. & HAI HYUN, J. 2006. Comparison of the characteristics of submucosal injection solutions used in endoscopic mucosal resection. Scandinavian Journal of Gastroenterology, 41, 488-492. JINDAL, U. C. 2012. Material Science and Metallurgy, Dorling Kindersley. JUNG, Y. S. & PARK, D. I. 2013. Submucosal injection solutions for endoscopic mucosal resection and endoscopic submucosal dissection of gastrointestinal neoplasms. Gastrointestinal Intervention, 2, 73-77. KAISER, M., KRUG, J. & ROSE, G. Interventional MRI: Minimal-invasive Surgery under MR guidance. Microwave Symposium Digest (MTT), 2011 IEEE MTT-S International, 5-10 June 2011 2011. 1-4. KALLOO, A. N., SINGH, V. K., JAGANNATH, S. B., NIIYAMA, H., HILL, S. L., VAUGHN, C. A., MAGEE, C. A. & KANTSEVOY, S. V. 2004. Flexible transgastric peritoneoscopy: a novel approach to diagnostic and therapeutic interventions in the peritoneal cavity. Gastrointestinal Endoscopy, 60, 114-117. KANTSEVOY SV, ADLER DG, CONWAY JD, DIEHL DL, FARRAYE FA, KWON R, MAMULA P, RODRIGUEZ S, SHAH RJ, WONG KEE SONG LM & WM., T. 2008. Endoscopic mucosal resection and endoscopic submucosal dissection. Technology Status Evaluation Report. American Society for Gastrointestinal Endoscopy. KEMNER, A. 1999. Experimental evaluation of traumatic properties of laparoscopic dissecting forceps. Delft, The Netherlands: Man-Machine Systems and Control, Delft University of Technology. KUME, M., MIYAZAWA, H., ABE, F., IWASAKI, W., UCHINAMI, H., SHIBATA, S., SATO, T. & YAMAMOTO, Y. 2008a. A newly designed magnet-retracting forceps for laparoscopic cholecystectomy in a swine model. Minimally Invasive Therapy, 17, 251-254. KUME, M., MIYAZAWA, H., IWASAKI, W., ABE, F., UCHINAMI, H. & YAMAMOTO, Y. 2008b. The Use of Magnetic Anchors in the Bowel Lumen for Laparoscopic Anterior Resection of Rectosigmoid Colon in Pigs: with Video. World Journal of Surgery, 32, 2425-2428. LACOMBE, R. 2006. Adhesion measurement methods: theory and practice, Taylor & Francis Group. LAM, A., KAUFMAN, Y., KHONG, S. Y., LIEW, A., FORD, S. & CONDOUS, G. 2009. Dealing with Complications in Laparoscopy. Best Practice & Research Clinical Obstetrics and Gynaecology, 23, 631-646. LEE, H., LEE, B. P. & MESSERSMITH, P. B. 2007. A reversible wet/dry adhesive inspired by mussels and geckos. Nature, 448, 338-341. LENZ, L., DI SENA, V., NAKAO, F. S., ANDRADE, G. P. D., ROHR, M. R. D. S. & FERRARI JR, A. P. 2010. Comparative results of gastric submucosal injection with hydroxypropyl methylcellulose, carboxymethylcellulose and normal saline solution in a porcine model. Arquivos de Gastroenterologia, 47, 184-187. LEVINE, G. N., GOMES AS FAU - ARAI, A. E., ARAI AE FAU - BLUEMKE, D. A., BLUEMKE DA FAU - FLAMM, S. D., FLAMM SD FAU - KANAL, E., KANAL E FAU - MANNING, W. J., MANNING WJ FAU - MARTIN, E. T., MARTIN ET FAU - SMITH, J. M., SMITH JM FAU - WILKE, N., WILKE N FAU - SHELLOCK, F. S. & SHELLOCK, F. S. 2007. Safety of Magnetic Resonance Imaging in Patients with Cardiovascular Devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation by American Heart Association, 116, 2878-2891. LIANG, Y. A., AUTUMN, K., HSIEH, S. T., ZESCH, W., CHAN, W. P., FEARING, R. S., FULL, R. J. & KENNY, T. W. Adhesion force measurements on single gecko setae. Solid-State Sensor and Actuator Workshop, June 4-8 2000 Hilton Head Island, South Carolina. 33-38. LIAO, S.-B., DOURMASHKIN, P. & BELCHER, J. 2004. Introduction to Electricity and Magnetism. MIT OpenCourseWare. LIEN, H.-H., HUANG, C.-C., TAN, L.-I., WANG, P.-C., LIN, H.-Z. & HUANG, C.-S. 2013. RE: Review of Cholecystotomy. LIN, C.-L., LEE, C.-F. & CHIU, W.-Y. 2005. Preparation and properties of poly(acrylic acid) oligomer stabilized superparamagnetic ferrofluid. Journal of Colloid and Interface Science, 291, 411-420. LIN, J. & VALENTINE, M. T. 2012a. High-force NdFeB-based magnetic tweezers device optimized for microrheology experiments. Review of Scientific Instruments, 83, 053905. LIN, J. & VALENTINE, M. T. 2012b. Ring-shaped NdFeB-based magnetic tweezers enables oscillatory microrheology measurements. Applied Physics Letters, 100, 201902-201902-4. LINDNER, A., DERKS, D. & SHELLEY, M. J. 2005. Stretch flow of thin layers of Newtonian liquids: Fingering patterns and lifting forces. Physics of Fluids, 17, 072107-072119. LIPFERT, J., HAO, X. & DEKKER, N. H. 2009. Quantitative Modeling and Optimization of Magnetic Tweezers. Biophysical journal, 96, 5040-5049. LIQUIDS RESEARCH LTD. 2014. Magnetic Fluid [Online]. Available: http://www.liquidsresearch.com/en-GB/products-46.aspx 2010]. LIRA, S. A. & MIRANDA, J. A. 2009a. Adhesion Properties of Chain-Forming Ferrofluids. Physical Review E, 79. LIRA, S. A. & MIRANDA, J. A. 2009b. Field-Controlled Adhesion in Confined Magnetorheological Fluids. Physical Review E, 80, 046313-(1-8). LOBE, T. E. 2003. Pediatric Laparoscopy, LeBonbeur Children's Medical Center, University of Tennessee, USA. LONG, R. & HUI, C.-Y. 2009. The effect of preload on the pull-off force in indentation tests of microfibre arrays. Proceedings of the Royal Society A: Mathematical, Physical and Engineering Science, 465, 961-981. LORENZ, B., KRICK BA FAU - MULAKALURI, N., MULAKALURI N FAU - SMOLYAKOVA, M., SMOLYAKOVA M FAU - DIELUWEIT, S., DIELUWEIT S FAU - SAWYER, W. G., SAWYER WG FAU - PERSSON, B. N. J. & PERSSON, B. N. 2013. Adhesion: Role of Bulk Viscoelasticity and Surface Roughness. Journal of Physics: Condensed Matter, 25, 225004-225020. MAHLE, S., ILG, P. & LIU, M. 2008. Hydrodynamic theory of polydisperse chain-forming ferrofluids. Physical Review E, 77, 016305. MALVERN®. 2014. Zetasizer Nano [Online]. Available: http://www.malvern.com/en/products/product-range/zetasizer-range/default.aspx 2012]. MCGEE, M. F., ROSEN, M. J., MARKS, J., ONDERS, R. P., CHAK, A., FAULX, S., CHEN, V. K. & PONSKY, J. 2006. A Primer on Natural Orifice Transluminal Endoscopic Surgery: Building a New Paradigm. Surgical Innovation, 13, 86-93. MEEKER, D. 2011. Finite Element Method Magnetics (FEMM) [Online]. Available: http://www.femm.info/wiki/HomePage. MENON, C., MURPHY, M., SITTI, M. & LAN, N. 2007. Space Exploration - Towards Bio-inspired Climbing Robots, Vienna, Austria. MERRIFIELD, B. F., WAGH, M. S. & THOMPSON, C. C. 2006. Peroral transgastric organ resection: a feasibility study in pigs. Gastrointestinal Endoscopy, 63, 693-697. MICROMOD PARTIKELTECHNOLOGIE GMBH. 2014. modular designed particles [Online]. Available: http://www.micromod.de/ 2010]. MINTZ, Y., HORGAN S FAU - CULLEN, J., CULLEN J FAU - STUART, D., STUART D FAU - FALOR, E., FALOR E FAU - TALAMINI, M. A. & TALAMINI, M. A. 2008. NOTES: a review of the technical problems encountered and their solutions. Journal of Laparoscopic & Advanced Surgical Techniques, 18, 583-587. MIRANDA, J. A. & OLIVEIRA, R. M. 2004. Adhesion Phenomena in Ferrofluids. Physical Review E, 70, 036311-(1-10). MORSI, H., YONG, K. L. & JEWELL, A. P. 2004. Evaluation of the Taguchi Methods for the Simultaneous Assessment of the Effects of Multiple Variables in the Tumour Microenvironment. Int Semin Surg Oncol, 20, 1-9. MULLER, O., HAHN, D. & LIU, M. 2006. Non-Newtonian behaviour in ferrofluids and magnetization relaxation. Journal of Physics: Condensed Matter, 18, S2623-S2632. MURPHY, M. P., TSO, W., TANZINI, M. & SITTI, M. Waalbot: An Agile Small-Scale Wall Climbing Robot Utilizing Pressure Sensitive Adhesives. Intelligent Robots and Systems, 2006 IEEE/RSJ International Conference on, 9-15 Oct. 2006 2006. 3411-3416. NAJMALDIN, A. & GUILLOU, P. 1998. A Guide to Laparoscopic Surgery, Leeds. NASE, J., LINDNER, A. & CRETON, C. 2008. Pattern Formation during Deformation of a Confined Viscoelastic Layer: From a Viscous Liquid to a Soft Elastic Solid. Physical Review Letters, 101, 074503. NATIONAL INSTRUMENTS®. 2014. NI USB-6008 12-Bit, 10 kS/s Low-Cost Multifunction DAQ [Online]. Available: http://sine.ni.com/nips/cds/view/p/lang/en/nid/201986 [Accessed 28. Sep. 2010. NEDOSEKIN, D. A., SHASHKOV EV FAU - GALANZHA, E. I., GALANZHA EI FAU - HENNINGS, L., HENNINGS L FAU - ZHAROV, V. P. & ZHAROV, V. P. 2010. Photothermal multispectral image cytometry for quantitative histology of nanoparticles and micrometastasis in intact, stained and selectively burned tissues. Cytometry Part A, 77, 1049-1058. NEUMAN, K. C. & NAGY, A. 2008. Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy. Nature Methods, 5, 491-505. NGUYEN, N. T., ROOT J FAU - ZAINABADI, K., ZAINABADI K FAU - SABIO, A., SABIO A FAU - CHALIFOUX, S., CHALIFOUX S FAU - STEVENS, C. M., STEVENS CM FAU - MAVANDADI, S., MAVANDADI S FAU - LONGORIA, M., LONGORIA M FAU - WILSON, S. E. & WILSON, S. E. 2005. Accelerated growth of bariatric surgery with the introduction of minimally invasive surgery. NOVEL INSTRUMENTS FOR MINIMALLY INVASIVE TECHNIQUES. 2010. Novel Instruments For Minimally Invasive Techniques [Online]. Available: http://www.imdi-nimit.nl/index.php?page=artikel&artikel_id=20. ODENBACH, S. 2004. Recent progress in magnetic fluid research. Journal of Physics: Condensed Matter, 16, R1135. OLYMPUS. 2014. Polypectomy, EMR & ESD [Online]. Available: http://www.olympus-europa.com/. OMEGA®. 2013-2014. Omega [Online]. Available: http://www.omega.com/pptst/LCAE.html 2010]. PAI, R. D., FONG, D. G., BUNDGA, M. E., ODZE, R. D., RATTNER, D. W. & THOMPSON, C. C. 2006. Transcolonic endoscopic cholecystectomy: a NOTES survival study in a porcine model (with video). Gastrointestinal Endoscopy, 64, 428-434. PAMME, N. 2006. Magnetism and microfluidics. Lab on a Chip, 6, 24-38. PAMME, N. & MANZ, A. 2004. On-Chip Free-Flow Magnetophoresis: Continuous Flow Separation of Magnetic Particles and Agglomerates. Analytical Chemistry, 76, 7250-7256. PARK, S., BERGS, R. A., EBERHART, R., BAKER, L., FERNANDEZ, R. & CADEDDU, J. A. 2007. Trocar-less Instrumentation for Laparoscopy Magnetic Positioning of Intra-abdominal Camera and Retractor. Annals of Surgery, 245, 379-384. PEARL, J. P. & PONSKY, J. L. 2007. Natural orifice transluminal endoscopic surgery: Past, present and future. J Min Access Surg 3, 43-46. PETIT, M., LEBOUC, A. K., AVENAS, Y., TAWK, M. & ARTEGA, E. 2011. Calculation and analysis of local magnetic forces in ferrofluids. Przegląd Elektrotechniczny, 87, 115-119. PHILOSOPHE, R. 2003. Avoiding Complications of Laparoscopic Surgery. Sexuality, Reproduction & Menopause, 1, 30-39. PIZZI, A. & MITTAL, K. L. 2003. Handbook of Adhesive Technology, Revised and Expanded, Taylor & Francis. POCIUS, A. V. 2002. Adhesion and Adhesives Technology: An Introduction, Hanser. POIVET, S. & ET AL. 2003. Cavitation-induced force transition in confined viscous liquids under traction. EPL (Europhysics Letters), 62, 244. POIVET, S., NALLET, F., GAY, C., TEISSEIRE, J. & FABRE, P. 2004. Force response of a viscous liquid in a probe-tack geometry: Fingering versus cavitation. The European Physical Journal E: Soft Matter and Biological Physics, 15, 97-116. PUANGMALI, P., ALTHOEFER, K., SENEVIRATNE, L. D., MURPHY, D. & DASGUPTA, P. 2008. State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery. Sensors Journal, IEEE, 8, 371-381. RABENOROSOA, K., CLEVY, C., LUTZ, P., GAUTHIER, M. & ROUGEOT, P. 2009. Measurement of pull-off force for planar contact at the microscale. Micro & Nano Letters, 4. RAMAN, J. D., SCOTT, D. J. & CADEDDU, J. A. 2009. Role of Magnetic Anchors During Laparoendoscopic Single Site Surgery and NOTES. JOURNAL OF ENDOUROLOGY, 23, 781-786. RAMARAJ, R., SUGUMARAN, A., KHAN, H., MATHIALAHAN, T. & GEORGE, P. 2011. Comparison of carbon dioxide (CO2) to air insufflation in colonoscopy. Gut, 60, A200. RENTSCHLER, M., DUMPERT, J., PLATT, S., FARRITOR, S. & OLEYNIKOV, D. 2007. Natural orifice surgery with an endoluminal mobile robot. Surgical Endoscopy, 21, 1212-1215. RENTSCHLER, M. E., DUMPERT, J., PLATT, S. R., OLEYNIKOV, D., FARRITOR, S. M. & IAGNEMMA, K. Mobile in vivo biopsy robot. Robotics and Automation, 2006. ICRA 2006. Proceedings 2006 IEEE International Conference on, 15-19 May 2006 2006. 4155-4160. RODRIGUES, S. P., HOREMAN T FAU - DANKELMAN, J., DANKELMAN J FAU - VAN DEN DOBBELSTEEN, J. J., VAN DEN DOBBELSTEEN JJ FAU - JANSEN, F.-W. & JANSEN, F. W. 2012. Suturing Intraabdominal Organs: When Do We Cause Tissue Damage? Surgical Endoscopy, 26, 1005-1009. ROSHAN, R., JAYNE, D. G., LISKIEWICZ, T., TAYLOR, G. W., GASKELL, P. H., CHEN, L., MONTELLANO-LOPEZ, A., MORINA, A. & NEVILLE, A. 2011. Effect of tribological factors on wet adhesion of a microstructured surface to peritoneal tissue. Acta Biomaterialia, 7, 4007-4017. RYOU, M. & THOMPSON, C. 2009. Magnetic retraction in natural-orifice transluminal endoscopic surgery (NOTES): addressing the problem of traction and countertraction. Endoscopy, 41, 143-148. SANGBAE, K., SPENKO, M., TRUJILLO, S., HEYNEMAN, B., SANTOS, D. & CUTKOSKY, M. R. 2008. Smooth Vertical Surface Climbing With Directional Adhesion. Robotics, IEEE Transactions on, 24, 65-74. SCHLAGER, A., KHALAILEH, A., SHUSSMAN, N., ELAZARY, R., KEIDAR, A., PIKARSKY, A., BEN-SHUSHAN, A., SHIBOLET, O., HORGAN, S., TALAMINI, M., ZAMIR, G., RIVKIND, A. & MINTZ, Y. 2010. Providing more through less: current methods of retraction in SIMIS and NOTES cholecystectomy. Surgical Endoscopy, 24, 1542-1546. SCHLIEMANN, H. & GOODMAN, S. M. 2011. A new study on the structure and function of the adhesive organs of the Old World sucker-footed bat (Myzopoda: Myzopodidae) of Madagascar. Verhandlungen des Naturwissenschaftlichen Vereins in Hamburg, 46, 313-330. SCOTT, D. J., TANG, S.-J., FERNANDEZ, R., BERGS, R., GOOVA, M. T., ZELTSER, I., KEHDY, F. J. & CADEDDU, J. A. 2007. Completely transvaginal NOTES cholecystectomy using magnetically anchored instruments. Surgical Endoscopy, 21, 2308-2316. SHAIKH, S. N. & THOMPSON, C. 2010a. Natural Orifice Translumenal Surgery: Flexible Platform Review. World Journal of Gastrointestinal Surgery, 2, 210-216. SHAIKH, S. N. & THOMPSON, C. C. 2010b. Natural orifice translumenal surgery: Flexible platform review. World Journal of Gastrointestinal Surgery, 2, 210-216. SHANG, J., PAYNE, C. J., CLARK, J., NOONAN, D. P., KWOK, K. W., DARZI, A. & YANG, G. Z. 2012. Design of a Multitasking Robotic Platform with Flexible Arms and Articulated Head for Minimally Invasive Surgery. 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems. SHAO, H., BACHUS, K. N. & STEWART, R. J. 2009. A Water-Borne Adhesive Modeled after the Sandcastle Glue of P. californica. Journal of Macromolecular Bioscience, 9, 464-471. SHAO, H. & STEWART, R. J. 2010. Biomimetic Underwater Adhesives with Environmentally Triggered Setting Mechanisms. Advanced Materials, 22, 729-733. SHINKAI, M. 2002. Functional magnetic particles for medical application. Journal of Bioscience and Bioengineering, 94, 606-613. SHLIOMIS, M. 2003. Ferrohydrodynamics: Retrospective and Issues. In: ODENBACH, S. (ed.) Ferrofluids. Springer Berlin Heidelberg. SILVA, A., SILVA-FREITAS, É., CARVALHO, J., PONTES, T., ARAÚJO-NETO, R., SILVA, K., CARRIÇO, A. & EGITO, E. 2012. Magnetic Particles in Biotechnology: From Drug Targeting to Tissue Engineering. SLOUGH, J. T. & MILLER, K. E. 2001. Small, high frequency probe for internal magnetic field measurements in high temperature plasmas. Review of Scientific Instruments, 72, 417-420. SNEDDON, I. N. 1965. The relation between load and penetration in the axisymmetric boussinesq problem for a punch of arbitrary profile. International Journal of Engineering Science, 3, 47-57. SOETIKNO, R. M., GOTODA, T., NAKANISHI, Y. & SOEHENDRA, N. 2003. Endoscopic mucosal resection. Gastrointestinal Endoscopy, 57, 567-579. SOUZA, G. R., MOLINA, J. R., RAPHAEL, R. M., OZAWA, M. G., STARK, D. J., LEVIN, C. S., BRONK, L. F., ANANTA, J. S., MANDELIN, J., GEORGESCU, M.-M., BANKSON, J. A., GELOVANI, J. G., KILLIAN, T. C., ARAP, W. & PASQUALINI, R. 2010. Three-dimensional tissue culture based on magnetic cell levitation. Nat Nano, 5, 291-296. STARK, A. Y., BADGE, I., WUCINICH, N. A., SULLIVAN, T. W., NIEWIAROWSKI, P. H. & DHINOJWALA, A. 2013. Surface wettability plays a significant role in gecko adhesion underwater. Proceedings of the National Academy of Sciences, 110, 6340-6345. STYLE, R. W., HYLAND, C., BOLTYANSKIY, R., WETTLAUFER, J. S. & DUFRESNE, E. R. 2013. Surface Tension and Contact with Soft Elastic Solids. Nat Commun, 4, 2728. SUMIYAMA, K., GOSTOUT, C. J., RAJAN, E., BAKKEN, T. A., DETERS, J. L., KNIPSCHIELD, M. A., HAWES, R. H., KALLOO, A. N., PASRICHA, P. J., CHUNG, S., KANTSEVOY, S. V. & COTTON, P. B. 2006. Pilot study of the porcine uterine horn as an in vivo appendicitis model for development of endoscopic transgastric appendectomy. Gastrointestinal Endoscopy, 64, 808-812. TAGUCHI, G. 1993. Taguchi on Robust Technology Development: Bringing Quality Engineering Upstream, ASME Press. TAYLOR, G., LISKIEWICZ, T., NEVILLE, A., MORINA, A. & GASKELL, P. H. 2009. Providing Adhesion for a Miniature Mobile Intra-Abdominal Device Based on Biomimetic Principles. 3rd Vienna International Conference NANO-TECHNOLOGY. Vienna. TAYLOR, G. W. & JAYNE, D. G. 2007. Robotic Applications in Abdominal Surgery: Their Limitations and Future Developments. The International Journal of Medical Robotics and Computer Assisted Surgery, 3, 3-9. TAYLOR, G. W., NEVILLE, A., JAYNE, D. G., ROSHAN, R., LISKIEWICZ, T., MORINA, A. & GASKELL, P. H. 2010. Wet adhesion for a miniature mobile intra-abdominal device based on biomimetic principles. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 224, 1473-1485. THE HEALTH AND SOCIAL CARE INFORMATION CENTRE 2012. National Bowel Cancer Audit (NBCA) Annual Report. NBCA. THE HEALTH AND SOCIAL CARE INFORMATION CENTRE 2013. National Bowel Cancer Audit (NBCA) Annual Report. TIETZE, R., JURGONS, R., LYER, S., SCHREIBER, E., WIEKHORST, F., EBERBECK, D., RICHTER, H., STEINHOFF, U., TRAHMS, L. & ALEXIOU, C. 2009. Quantification of drug-loaded magnetic nanoparticles in rabbit liver and tumor after in vivo administration. Journal of Magnetism and Magnetic Materials, 321, 1465-1468. TIETZE, R., RAHN H FAU - LYER, S., LYER S FAU - SCHREIBER, E., SCHREIBER E FAU - MANN, J., MANN J FAU - ODENBACH, S., ODENBACH S FAU - ALEXIOU, C. & ALEXIOU, C. 2011. Visualization of superparamagnetic nanoparticles in vascular tissue using XmuCT and histology. Histochen and Cell Biology, 135, 153-158. TOLEDO, L., GOSSOT D FAU - FRITSCH, S., FRITSCH S FAU - REVILLON, Y., REVILLON Y FAU - REBOULET, C. & REBOULET, C. 1999. Study of Sustained Forces and The Working Space of Endoscopic Surgery Instruments. Annales de Chirurgie, 53, 587-897. TORTORA, G., SALERNO, M., RANZANI, T., TOGNARELLI, S., DARIO, P. & MENCIASSI, A. A modular magnetic platform for natural orifice transluminal endoscopic surgery. Annual International Conference of the IEEE EMBS, 3 - 7 July 2013 2013 Osaka, Japan. 6265-6268. TRAN CAO, H. S., LOPEZ, N., CHANG, D. C. & ET AL. 2014. Improved perioperative outcomes with minimally invasive distal pancreatectomy: Results from a population-based analysis. JAMA Surgery, 149, 237-243. TRIEF & OLK. 2013. Schematic of Laparoscopic Cholecystectomic Surgery [Online]. Available: http://www.laparoscopicsurgeryinfo.com/images/laparoscopic1.jpg 2013]. UEMATSU, D., AKIYAMA, G., MAGISHI, A., NAKAMURA, J. & HOTTA, K. 2010. Single-Access Laparoscopic Left and Right Hemicolectomy Combined With Extracorporeal Magnetic Retraction. Diseases of the Colon & Rectum, 53, 944-948. VAN DER VOORT, M., HEIJNSDIJK, E. A. M. & GOUMA, D. J. 2004. Bowel Injury as a Complication of Laparoscopy. British Journal of Surgery, 91, 1253-1258. VÉKÁS, L. 2008. Ferrofluids and Magnetorheological Fluids. Advances in Science and Technology, 54, 127-136. VIGNAUD, A., MAÎTRE, X., GUILLOT, G., DURAND, E., DE ROCHEFORT, L., ROBERT, P., VIVÈS, V., SANTUS, R. & DARRASSE, L. 2005. Magnetic susceptibility matching at the air–tissue interface in rat lung by using a superparamagnetic intravascular contrast agent: Influence on transverse relaxation time of hyperpolarized helium-3. Magnetic Resonance in Medicine, 54, 28-33. VONCK, D. 2013a. The Feasibility of Vacuum Technique in Minimal Invasive Surgery. PhD Thesis, Delft University of Technology. VONCK, D. 2013b. The feasibility of vacuum technique in minimal invasive surgery: Improving the patient safety through instrument design. Delft University of Technology. VONCK, D., GOOSSENS, R. H. M., EIJK, D. J., HINGH, I. H. J. T. & JAKIMOWICZ, J. J. 2010. Vacuum grasping as a manipulation technique for minimally invasive surgery. Surgical Endoscopy, 24, 2418-2423. VONCK, D., JAKIMOWICZ, J. J., LOPUHAÄ, H. P. & GOOSSENS, R. 2011. Grasping soft tissue by means of vacuum technique. Medical Engineering & Physics. VONCK, D., JAKIMOWICZ, J. J., LOPUHAÄ, H. P. & GOOSSENS, R. H. M. 2012. Grasping soft tissue by means of vacuum technique. Medical Engineering & Physics, 34, 1088-1094. WAGH, M. S., MERRIFIELD, B. F. & THOMPSON, C. C. 2006. Survival studies after endoscopic transgastric oophorectomy and tubectomy in a porcine model. Gastrointestinal Endoscopy, 63, 473-478. WANG, Y., WERTHEIM, D. F., JONES, A. S. & COOMBES, A. G. A. 2010a. Micro-CT in drug delivery. European Journal of Pharmaceutics and Biopharmaceutics, 74, 41-49. WANG, Z., BROWN, A. W., BROWN, S. I., WANG, L., ANDRE, P., FLORENCE, G. J. & CUSCHIERI, A. Intra-luminal injection of ferro-fluid for magnetic bowel retraction in minimal access surgery. Mechatronics and Embedded Systems and Applications (MESA), 2010 IEEE/ASME International Conference on, 15-17 July 2010 2010b. 168-173. WANG, Z., SCHMIDT, A., BROWN, S. I., BROWN, A., MCLEAN, D., FLORENCE, G. J., ANDRE, P. & CUSCHIERI, A. 2012. Design and Evaluation of Permanent Magnet-Based Probe Having Adjustable Magnetic Force for Bowel Retraction in Laparoscopic Surgery. Society of American Gastrointestinal and Endoscopic Surgeons (SAGES). San Diego, The USA. WANG, Z., WANG, L., BROWN, S. I., FRANK, T. G. & CUSCHIERI, A. 2009. Ferromagnetization of Target Tissues by Interstitial Injection of Ferrofluid: Formulation and Evidence of Efficacy for Magnetic Retraction. IEEE Transactions on Biomedical Engineering, 56, 2244-2252. WANG, Z., WANG, L., TANG, B., FRANK, T., BROWN, S. & CUSCHIERI, A. 2008. Retraction by Surface Ferromagnetisation of Target Tissues: Preliminary Studies on Feasibility of Magnetic Retraction for Endoscopic Surgery. Surgical Endoscopy, 22, 1838-1844. WÉBER, G., LANTOS, J., BORSICZKY, B., FERENCZ, A., JANCSÓ, G., FERENCZ, S., HORVÁTH, S., BAHRI, H. H., TAKÁCS, I. & BALATONYI, B. 2008. Basic Surgical Techniques, University of Pécs, Medical School. WESTEBRING-VAN DER PUTTEN, E. P. 2011. A Sense of Touch in Laparoscopy: Using Augmented Haptic Feedback to Improve Grasp Control. PhD Thesis, Delft University of Technology. YAMAUCHI, Y., YAMASHITA, J., MORIKAWA, O., HASHIMOTO, R., MOCHIMARU, M., FUKUI, Y., UNO, H. & YOKOYAMA, K. 2002. Surgical Skill Evaluation by Force Data for Endoscopic Sinus Surgery Training System. In: DOHI, T. & KIKINIS, R. (eds.) Medical Image Computing and Computer-Assisted Intervention — MICCAI 2002. Springer Berlin Heidelberg. ZABER TECHNOLOGIES INC.®. 2014. Zaber Technologies Inc. [Online]. Available: http://www.zaber.com/products/product_detail.php?detail=T-LSR075B#tabs 2013]. ZELTSER, I. S., BERGS, R., FERNANDEZ, R., BAKER, L., EBERHART, R. & CADEDDU, J. A. 2007. Single Trocar Laparoscopic Nephrectomy Using Magnetic Anchoring and Guidance System in the Porcine Model. The Journal of Urology, 178, 288-291. ZELTSER, I. S. & CADEDDU, J. A. 2008. A Novel Magnetic Anchoring and Guidance System to Facilitate Single Trocar Laparoscopic Nephrectomy. Current Urology Reports, 9, 62-64."],"dcterms:accessrights":["public"],"dc:title":["Tissue manipulation using nano-particles ferrofluids for minimal access surgical applications"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T21:30:02Z"}