{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:9311"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:9311","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Optimisation Of Fixation Methods For Vancouver Type B2 And B3 Periprosthetic Femoral Fracture Treatment","abstract":"Periprosthetic femoral fractures (PFF) are a complication associated with total hip arthroplasty patients that can be both traumatic and challenging to treat. With the increasing age of the population and increasing prevalence of hip replacement surgery periprosthetic femoral fractures are expected to occur more frequently in the future. The most common type of PFF is the Vancouver Type B fracture that occurs near the tip of the original prosthesis. These fractures can be complicated further by loosening of the primary femoral stem (Type B2 fractures) and poor bone stock (Type B3 fractures). Clinical failures and unclear optimal treatment recommendations for many fractures suggest that further investigation is required. This study mechanically tested experimental specimens representing the cemented long stem revision treatment of a Type B2 PFF at a range of loading orientations to evaluate their biomechanical response. From these specimens the axial stiffness, medial axial strain, distal lateral axial strain, and relative fracture movement were recorded under semi-physiological loading. These experimental results were also used to validate computational, finite element (FE), models of long stem PFF treatment. The computational models were shown to achieve reasonable agreement with the experimental data, such that they could be used to investigate a wider range of clinical scenarios. The FE models were then used to compare the relative effects of different cement mantle geometries, fracture location, fracture bridging distance, fracture angle, revision femoral stem length and osteoporosis. The specific location and angle of the fracture appeared to have an effect on the bending response of the femur and the optimal treatment. Long stem revision treatment however seemed to be suitable for achieving stability around an unstable fracture and it may be possible to counter-act the increased risk of fixation failure in osteoporotic patients by selecting a longer bridging distance.","abstract_html":"Periprosthetic femoral fractures (PFF) are a complication associated with total hip arthroplasty patients that can be both traumatic and challenging to treat. With the increasing age of the population and increasing prevalence of hip replacement surgery periprosthetic femoral fractures are expected to occur more frequently in the future. The most common type of PFF is the Vancouver Type B fracture that occurs near the tip of the original prosthesis. These fractures can be complicated further by loosening of the primary femoral stem (Type B2 fractures) and poor bone stock (Type B3 fractures). Clinical failures and unclear optimal treatment recommendations for many fractures suggest that further investigation is required. This study mechanically tested experimental specimens representing the cemented long stem revision treatment of a Type B2 PFF at a range of loading orientations to evaluate their biomechanical response. From these specimens the axial stiffness, medial axial strain, distal lateral axial strain, and relative fracture movement were recorded under semi-physiological loading. These experimental results were also used to validate computational, finite element (FE), models of long stem PFF treatment. The computational models were shown to achieve reasonable agreement with the experimental data, such that they could be used to investigate a wider range of clinical scenarios. The FE models were then used to compare the relative effects of different cement mantle geometries, fracture location, fracture bridging distance, fracture angle, revision femoral stem length and osteoporosis. The specific location and angle of the fracture appeared to have an effect on the bending response of the femur and the optimal treatment. Long stem revision treatment however seemed to be suitable for achieving stability around an unstable fracture and it may be possible to counter-act the increased risk of fixation failure in osteoporotic patients by selecting a longer bridging distance.","abstract_has_math":false,"creators":["Etchels, Lee William"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Wilcox, Ruth","Jones, Alison","Tsiridis, Eleftherios","Jin, Zhongmin"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-10","date_published":"2014-10","updated_at":"2026-11-18T21:30:57Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.655253"],"render_values":[{"text":"uk.bl.ethos.655253","href":null,"code":true}]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["Latta Fellowship","WT 088908/Z/09/Z","Collaboration with Leeds Musculoskeletal Biomedical Research Unit","Provided surgical components"],"render_values":[{"text":"Latta Fellowship","href":null,"code":true},{"text":"WT 088908/Z/09/Z","href":null,"code":true},{"text":"Collaboration with Leeds Musculoskeletal Biomedical Research Unit","href":null,"code":true},{"text":"Provided surgical components","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/9311/1/Checked_Corrected_Final_Thesis_LeeEtchels.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A9311","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wilcox, Ruth","Jones, Alison","Tsiridis, Eleftherios","Jin, Zhongmin"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["British Orthopaedic Association","Wellcome Trust and EPSRC","National Institute for Health Research","Stryker UK"]},{"key":"dc:creator","label":"Author","values":["Etchels, Lee William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-10"]},{"key":"dc:date.issued","label":"Date","values":["2014-10"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/9311/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["1. National Joint Registry, 2013. Executive summary: public and patient guide to the NJR's 10th annual report 2013. Hemel Hempstead: NJR. Available at www.njrcentre.org.uk [Accessed May 2014]. 2. Tsiridis, E., Pavlou, G., Venkatesh, R., Bobak, P., Gie, G., 2009. Periprosthetic femoral fractures around hip arthroplasty: Current concepts in their management. Hip International 19 no. 2, 75-86. 3. Nho, S.J., Kymes, S.M., Callaghan, J.J., Felson, D.T., 2013. The burden of hip osteoarthritis in the United States: Epidemiologic and economic considerations. J. Am. Acad. Orthop. Surg. 21, S1-6. 4. Lever, J.P., Zdero, R., Nousiainen, M.T., Waddell, J.P., Schemitsch, E.H., 2010. The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty. Journal of Orthopaedic Surgery and Research 5, 45. 5. Chen, G., Schmutz, B., Wullschleger, M., Pearcy, M.J., Schuetz, M.A., 2009. Computational investigations of mechanical failures of internal plate fixation. Proc. IMechE Vol. 224 Part H: J. Engineering in Medicine, 119-126. 6. Lindahl H, Malchau H, Oden A, et al. Risk factors for failure after treatment of a periprosthetic fracture of the femur. J Bone Joint Surg Br 2006;88:26. 7. Buttaro MA, Farfalli G, Paredes Nunez M, et al. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am 2007;89:1964. 8. Graham SM, Moazen M, Leonidou A, et al. Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 cases. J Orthop Sci 18, 426-436. 9. Schmotzer, H., Tchejeyan, G.H., Dall, D.M., 1996. Surgical management of intra-and postoperative fractures of the femur about the tip of the stem in total hip arthroplasty. J. Arthroplasty 11, 709-717. 10. Zdero, R., Walker, R., Waddell, J.P., Schemitsch, E.H., 2008. Biomechanical evaluation of periprosthetic femoral fracture fixation. J. Bone Joint Surg. Am. 90, 1068-1077. 11. Tsiridis, E., Haddad, F.S., Gie, G.A., 2003. Dall-Miles plates for periprosthetic femoral fractures a critical review of 16 cases. Injury, Int. J. Care Injured 34, 107-110. 12. Sommers, M.B., Fitzpatrick, D.C., Madey, S.M., Zanderschulp, C.V., Bottlang, M., 2007. A surrogate long-bone model with osteoporotic material properties for biomechanical testing of fracture implants. J. Biomech. 40, 3297-3304. 13. Moazen, M., Jones, A.C., Jin, Z., Wilcox, R.K., 2011. Periprosthetic fracture fixation of the femur following total hip arthroplasty: A review of biomechanical testing. Clin. Biomech. 26 (1), 13-22. 14. Cristofolini, L., Viceconti, M., Cappello, A., Toni, A., 1996. Mechanical validation of whole bone composite femur models. J. Biomechanics, Vol. 29, No. 4, 525-535. 15. Cristofolini, L., Viceconti, M., 2000. Mechanical validation of whole bone composite tibia models. J. Biomech. 33, 279-288. 16. Mak, J.H., 2013. Optimisation of locking plate fixation methods for periprosthetic fractures. PhD thesis. University of Leeds. 17. Briant-Evans, T.W., Veeramootoo, D., Tsiridis, T., Hubble, M.J., 2009. Cement-in-cement stem revision for Vancouver type B periprosthetic femoral fractures after total hip arthroplasty. Acta Orthopaedica 80 (5), 548-552. 18. Mak, J.H., Moazen, M., Jones, A.C., Jin, Z., Tsiridis, E., Wilcox, R.K., 2012. J. Bone Joint Surg. Br. 94-B (74). 19. Moazen, M., Mak, J.H., Etchels, L.W., Jin, Z., Wilcox, R.K., Jones, A.C., Tsiridis, E., 2014. Periprosthetic femoral fracture - a biomechanical comparison between Vancouver Type B1 and B2 fixation methods. J. Arthroplasty 29, 495-500. 20. Moazen, M., Mak, J.H., Etchels, L.W., Jin, Z., Wilcox, R.K., Jones, A.C., Tsiridis, E., 2013. The effect of fracture stability on the performance of locking plate fixation in periprosthetic femoral fractures. J. Arthroplasty 28, 1589-1595. 21. Moazen, M., Jones, A.C., Leonidou, A., Jin, Z., Wilcox, R.K., Tsiridis, E., 2012. Rigid versus flexible plate fixation for periprosthetic femoral fracture - computer modelling of a clinical case. Med. Eng. Phys. 34, 1041-1048. 22. Moazen, M., Mak, J.H., Jones, A.C., Jin, Z., Wilcox, R.K., Tsiridis, E., 2013. Evaluation of a new approach for modelling the screw-bone interface in a locking plate fixation:a corroboration study. Proc. IMechE Part H: J. Engineering in Medicine 227(7), 746-756. 23. Moazen, M., Mak, J.H., Etchels, L.W., Jones, A.C., Jin, Z., Wilcox, R.K., Tsiridis, E., 2013. Why do periprosthetic femoral fracture fixations fail - a biomechanical investigation. Bone & Joint Journal Orthopaedic Proceedings Supplement 95 (16), 62. 24. Moazen, M., Jones, A.C., Mak, J., Jin, Z., Wilcox, R.K., Tsiridis, E., 2011. The computational evaluation of a locking plate fixation - locking versus far cortical screws. Proceedings of the ASME 2011 Summer Bioengineering Conference. 25. Cox, B.D., 2006.Measurement of bone cement properties using self-sensing techniques. PhD thesis, University of Leeds. 26. Gie, G.A., Linder, L., Ling, R.S.M., Simon, J-P., Slooff, T.J.J.H., Timperley, A.J., 1993. Impacted cancellous allografts and cement for revision total hip arthroplasty. J. Bone Joint Surg. (Br) 75-B, 14-21. 27. Kusakabe, H., Sakamaki, T., Nihei, K., Oyama, Y., Yanagimoto, S., Ichimiya, M., Kimura, J., Toyama, Y., 2004. Osseointegration of a hydroxyapatite-coated multilayered mesh stem. Biomaterials 25, 2957-2969. 28. Lakstein, D., Kopelovitch, W., Barkay, Z., Bahaa, M., Hendel, D., Eliaz, N., 2009. Enhanced osseiointegration of grit-blasted, NaOH-treated and electrochemically hydroxyapatite-coated Ti-6Al-4V implants in rabbits. Acta Biomaterialia 5, 2258-2269. 29. Kelley, S.S., 1994. Periprosthetic femoral fractures. J. Am. Acad. Orthop. Surg. 2, 164-172. 30. Beals, R.K., Tower, S.S., 1996. Periprosthetic fractures of the femur: An analysis of 93 fractures. Clin. Orthop. Relat. Res. 327, 238-246. 31. Corten, K., Vanrykel, F., Bellemans, J., Reynders Frederix, P., Simon, J.-P., Broos, P.L.O., 2009. An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component. J. Bone Joint Surg. (Br) 91-B (11), 1424-1430. 32. Masri, B.A, Meek, R.M.D, Duncan, C.P., 2004. Periprosthetic fractures evaluation and treatment. Clin. Orthop 420, 80-95. 33. Adolphson, P., Jonsson, U., Kalen, R., 1987. Fractures of the ipsilateral femur after total hip arthroplasty. Arch. Orthop. Trauma Surg. 106, 353-357. 34. Cooke, P.H., Newman, J.H., 1988. Fractures of the femur in relation to cemented hip prostheses. J. Bone Joint Surg. (Br) 70-B, 386-9. 35. Johansson, J.E., McBroom, R., Barrington, T.W., Hunter, G.A., 1981. Fracture of the ipsilateral femur in patients with total hip replacement. J. Bone Joint Surg. (Am) 63 (9), 1435-1442. 36. Kavanagh, B.F.,1992. Femoral fractures associated with total hip arthroplasty. Orthop. Clin. North Am. 23, 249-257. 37. Mallory, T.H., Kraus, T.J., Vaughn, B.K., 1989. Intraoperative femoral fractures associated with cementless total hip arthroplasty. Orthopedics 12, 231-239. 38. Schwartz, J.T., Mayer, J.G., Engh, C.A., 1989. Femoral fracture during non-cemented total hip arthroplasty. J. Bone Joint Surg. (Am) 71 (8), 1135-1142. 39. Stuchin, S.A., 1990. Femoral shaft fracture in porous and press-fit total hip arthroplasty. Orthop. Rev. 19 (2), 153-9. 40. Roffman, M., Mendes, D.G., 1989. Fracture of the femur after total hip arthroplasty. Orthopedics 12 (8), 1067-1070). 41. Duncan, C.P., Masri, B.A., 1995. Fractures of the femur after hip replacement. Instr. Course Lect. 45, 293-304. 42. Kamineni, S., Vindlacheruvu, R., Ware, H.E., 1999. Peri-prosthetic femoral shaft fractures treated with plate and cable fixation. Injury Int. J. Care Injured 30, 261-268. 43. Grammatopoulos, G., Pandit, H., Kambouroglou, G., Deakin, M., Gundle, R., McLardy-Smith, P., Taylor, A., Murray, D., 2011. A unique peri-prosthetic fracture pattern in well fixed femoral stems with polished, tapered, collarless, design of total hip replacement. Injury Int. J. Care Injured 42 (11), 1271-6. 44. O'Shea, K., Kutty, S., Quinlan, J.F., Brady, O.H., Mulcahy, D., 2005. The use of uncemented extensively porous-coated femoral components in the management of Vancouver B2 and B3 periprosthetic femoral fractures. J. Bone Joint Surg. (Br) 87-B (12), 1617-21. 45. Leonidou, A., Moazen, M., Lepetsos, P., Graham, S.M., Macheras, G.A., Tsiridis, E., 2015. The biomechanical effect of bone quality and fracture topography on locking plate fixation in periprosthetic femoral fractures. Injury Int. J. Care Injured 46, 213-217. 46. Yoshida, Y., Osaka, S., Kojima, T., Taniguchi, M., Osaka, E., Tokuhashi, Y., 2012. Revision of tumor prosthesis of the knee joint. Eur. J. Orthop. Surg. Traumatol. 22, 387-394. 47. Cannon, S.R., 1997. Massive prostheses for malignant bone tumours of the limbs. Eu. Instr. Course Lect. 3. 48. Springer, B.D., Berry, D.J., Lewallen, D.G., 2003. Treatment of periprosthetic femoral fractures following total hip arthroplasty with femoral component revision. J. Bone Joint Surg. Am. 85, 2156-2162. 49. Venu, K.M., Koka, R., Garikipati, R., Shenava, Y., Madhu, T.S., 2001. Dall-Miles cable and plate fixation for the treatment of peri-prosthetic femoral fractures - analysis of results in 13 cases. Injury, Int. J. Care Injured 32, 395-400. 50. Tadross, T.S.F., Nanu, A.M., Buchanan, M.J., Checketts, R.G., 2000. Dall-Miles plating for periprosthetic B1 fractures of the femur. J. Arth. 15 (1), 47-51. 51. Lewallen, D.G., Berry, D.J., 1997. Periprosthetic fracture of the femur after total hip arthroplasty. J. Bone Joint Surg. (Am) 79-A (12), 1881-1890. 52. Oh, J.K., Shau, D., Ahn, Y.H., Lee, S.J., Tsutsumi, S., Hwang, J.H., Jung, D.Y., Perren, S.M., Oh, C.W., 2009. Effect of fracture gap on stability of compression plate fixation: a finite element study. J. Orthop. Res. 28 (4), 462-7. 53. Mann, K.A., Ayers, D.C., Damron, T.A., 1997. Effects of stem length on mechanics of the femoral hip component after cemented revision. J. Orthop. Res. 15, 62-68. 54. Pellicci, P.M., Wilson Jr, P.D., Sledge, C.B., Salvati, E.A., Ranawat, C.S., Poss, R., Callaghan, J.J., 1985. Long-term results of revision total hip replacement. A follow up report. J. Bone Joint Surg. (Am) 67 (4), 513-516. 55. Froberg, L., Troelsen, A., Brix, M., 2012. Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis. Acta Orthopaedica 83 (6), 648-652. 56. Otani, T., Whiteside, L.A., White, S.E., 1993b. Effect of femoral component material properties on cementless fixation in total hip arthroplasty. J. Arthrop. 8, 67-74. 57. Tsiridis, E., Narvani, A.A., Haddad, F.S., Timperley, J.A., Gie, G.A., 2004. Impaction femoral allografting and cemented revision for periprosthetic femoral fractures. J Bone Joint Surg. (Br) 96-B, 1124-32. 58. Moreland, J.R., Bernstein, M.L., 1995. Femoral revision hip arthroplasty with uncemented, porous-coated stems. Clin. Orthop. Relat. Res. 319, 141-150. 59. Huiskes, R., Weinans, H., Rietbergen, B.V., 1992. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin. Orthop. Relat. Res. 274, 124-134. 60. Marsland, D., Mears, S.C., 2012. A review of periprosthetic femoral fractures associated with total hip arthroplasty. Geriatr. Orthop. Surg. Rehabil. 2012, 3(3), 107-120. 61. Byrne, D.P., Mulhall, K.J., Baker, J.F., 2010. Anatomy & Biomechanics of the hip. The Open Sports Medicine Journal 4, 51-57. 62. Schuenke, M., Schulte, E., Schumacher, U., 2006. THIEME Atlas of Anatomy. In: Ross L, Lamperti E, Eds. General Anatomy of the Musculoskeletal System. Thieme, New York. 63. Marieb, E.N. Human Anatomy and Physiology. 2004. 64. Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., Duda, G.N., 2001. Hip contact forces and gait patterns from routine activities. J. Biomech. 34, 859-871. 65. Rohrle, H., Scholten, R., Sigolotto, C., Sollbach, W., Kellner, H., 1984. Joint forces in the human pelvis-leg skeleton during walking. J. Biomech. 17 (6), 409-424. 66. Thornton-Trump, A.B., Daher, R., 1975. The prediction of reaction forces from gait data. J. Biomech. 8, 173-178. 67. Paul, J.P., 1974. Techniques of gait analysis. Proc. Roy. Soc. Med. 67, 401-404. 68. Brand, R.A., Pedersen, D.R., Davy, D.T., Kotzar, G.M., Heiple, K.G., Goldberg, V.M., 1994. Comparison of hip force calculations and measurements in the same patient. J. Arthrop. 9 (1), 45-51. 69. Aamodt, A., Lund-Larson, J., Eine, J., Anderson, E., Benum, P., Schnell Husby, O., 1997. In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur. J. Orthop. Res. 15, 927-931. 70. Genda, E., Iwasaki, N., Li, G., MacWilliams, A., Barrance, P.J., Chao, E.Y.S, 2001. Normal hip joint contact pressure distribution in single-leg standing - effect of gender and anatomic parameters. J. Biomech. 34, 895-905. 71. Seireg, A., Arvikar, R.J., 1975. The prediction of muscular load sharing and joint forces in the lower extremities during walking. J. Biomech. 8, 89-102. 72. Paul, J.P., 1967. Forces at the human hip joint. PhD Thesis, University of Glasgow. 73. Crowninshield, R.D., Johnston, R.C., Andrews, J.G., Brand, R.A., 1978. A biomechanical investigation of the human hip. J. Biomech. 11, 75-85. 74. Horak, F.B., Henry, S.M., Shumway-Cook, A., 1997. Postural perturbations: New insights for treatment of balance disorders. Phys. Ther. 77, 517-533. 75. Johnson, F., Leitl, S., Waugh, W., 1980. The distribution of load across the knee, a comparison of static and dynamic measurements. J. Bone Joint Surg (Br) 62-B (3), 346-349. 76. Hagstedt, B., Norman, O., Olsson, T.H., Tjornstrand, B., 1980. Technical accuracy in high tibial osteotomy for gonarthrosis. Acta Orthop. Scand. 51, 963-970. 77. Koshino, T., Tsuchiya, K., 1979. The effect of high tibial osteotomy on osteoarthritis of the knee. Int. Orthop. 3, 37-45. 78. Yang, N.H., Canavan, P.K., Nayeb-Hahemi, H., 2010. The effect of the frontal plane tibiofemoral angle and varus knee moment on the contact stress and strain at the knee cartilage. J. Applied Biomechanics 26, 432-443. 79. Karachalios, T.H., Sarangi, P.P., Newman, J.H., 1994. Severe varus and valgus deformities treated by total knee arthroplasty. J. Bone Joint Surg. (Br) 76-B (6), 938-942. 80. Lotz, J., Gerhart, T.,N., Hayes, W.C., 1991. Mechanical properties of metaphyseal bone in the proximal femur. J. Biomech. 24 (5), 317-329. 81. Carter, D.R., Hayes, W.C., 1976. Fatigue life of compact bone - I Effects of stress, amplitude, temperature and density. J. Biomech. 9, 27-34. 82. Rho, J-Y, Kuhn-Spearing, L., Zioupos, P., 1998. Mechanical properties and the hierarchical structure of bone. Med. Eng. & Phys. 20, 92-102. 83. Shahar, R., Zaslansky, P., Barak, M., Friesem, A.A., Currey, J.D., Weiner, S., 2007. Anisotropic Poisson's ratio and compression modulus of cortical bone determined y speckle interferometry. J. Biomech. 40, 252-264. 84. Reilly, D.T., Burstein, A.H., 1975. The elastic and ultimate properties of compact bone tissue. J. Biomech. 8 (6), 393-396. 85. Morgan, E.F., Bayraktar, H.H., Keaveny, T.M., 2003. Trabecular bone modulus-density relationships depend on anatomic site. J. Biomech. 36, 897-904. 86. Morgan, E.F., Keaveny, T.M., 2001. Dependence of yield strain of human trabecular bone on anatomic site. J. Biomech. 34, 569-577. 87. Bayraktar, H.H., Morgan, E.F., Niebur, G.L., Morris, G.E., Wong, E.K., Keaveny, T.M., 2004. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. J. Biomech. 37, 27-35. 88. Reilly, D.T., Burstein, A.H., Frankel, V.H., 1974. The elastic modulus for bone. J. Biomech. 7, 271-275. 89. Rho, J-Y., Ashman, R.B., Turner, C.H., 1993. Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements. J. Biomech. 26 (2), 111-119. 90. Turner, C.H., Rho, J., Takano, Y., Tsui, T.Y., Pharr, G.M., 1999. The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques. J. Biomech. 32, 437-441. 91. Berteau, J-P., Baron, C., Pithioux, M., Launay, F., Chabrand, P., Lasaygues, P., 2014. In vitro ultrasonic and mechanic characterization of the modulus of elasticity of children cortical bone. Ultrasonics 54, 1270-1276. 92. Abdel-Wahab, A.A., Alam, K., Silberschmidt, V.V., 2011. Analysis of anisotropic viscoelastoplastic properties of cortical bone tissues. J. Mech. Behav. Biomed. Mater. 4, 807-820. 93. Johnson, T.P.M., Socrate, S., Boyce, M.C., 2010. A viscoelastic, viscoplastic model of cortical bone valid at low and high strain rates. Acta Biomaterialia 6, 4073-4080. 94. Brown, S.J., Pollintine, P., Powell, D.E., Davie, M.W.J., Sharp, C.A., 2002. Regional differences in mechanical and material properties of femoral head cancellous bone in health and osteoarthritis. Calcif. Tissue Int. 71, 227-234. 95. Linde, F., Hvid, I., Pongsoipetch, B., 1989. Energy absorptive properties of human trabecular bone specimens during axial compression. J. Orthop. Res. 7, 432-439. 96. Homminga, J., McCreadie, B.R., Ciarelli, T.E., Weinans, H., Goldstein, A., Huiskes, R., 2002. Cancellous bone mechanical properties from normals and patients with hip fractures differ on the structural level, not on the bone hard tissue level. Bone 30 (5), 759-764. 97. Chevalier, Y., Pahr, D., Allmer, H., Charlebois, M., Zysset, P., 2007. Validation of a voxel-based FE method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation. J. Biomech. 40, 3333-3340. 98. Rho, J-Y., Tsui, T.Y., Pharr, G.M., 1997. Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. Biomaterials 18, 1325-1330. 99. Ulrich, D., Hildebrand, T., Van Rietbergen, B., Ruegsegger, P., 1997. The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing. Stud. Health Technol. Inform. 40, 97-112. 100. Zysset, P.K., Guo, X. E., Hoffler, C.E., Moore, K.E., Goldstein, S.A., 1999. Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur. J. Biomech. 32, 1005-1012. 101. Ninomi, M., 2002. Recent materials for biomedical applications. Metallurgical and Materials Transactions A 33A, 477-486. 102. Hermawan, H., Ramdan, D., Djuansjah, J.R.P., 2011. Metals for Biomedical Applications, Biomedical Engineering - From Theory to Applications, Prof. Reza Fazel (Ed.), ISBN: 978-953-307-637-9, InTech, Available from: http://www.intechopen.com/books/biomedical-engineering-from-theory-toapplications/metals-for-biomedical-applications. 103. Uhthoff, H.K., Poitras, P., Backman, D.S., 2005. Internal plate fixation of fractures: Short history and recent developments. J. Orthop. Sci. 11, 118-126. 104. Claes, L.E., Cunningham, J.L., 2009. Monitoring the mechanical properties of healing bone. Clin. Orthop. Relat. Res. 467, 1964-1971. 105. Perren, S.M., 2002. Evolution of the internal fixation of long bone fractures. J. Bone Joint Surg. [Br] 84-B, 1093-1110. 106. Perren, S.M., Cordey, J., Rahn, B.A., Gautier, E., Schneider, E., 1988. Early temporary porosis of bone induced by internal fixation implants. Clin. Orthop. Relat. Res. 232, 139-51. 107. Berhmann, G., Graichen, F., Rohlmann, A., 1993. Hip joint loading during walking and running, measured in two patients. J. Biomech. 26 (8), 969-990. 108. Sawbones, 2014. Biomechanical Test Materials 2014. Available at www.sawbones.com [Accessed January 2015]. 109. Basso, T., Klaksvik, J., Syversen, U., Foss, O.A., 2014. A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures. J. Biomech. 47, 3898-3902. 110. Brock, G.R., Chen, J.T., Ingraffea, A.R., MacLeay, J., Pluhar, G.E., Boskey, A.L., van der Meulen, M.C.H., 2015. The effect of osteoporosis treatments on fatigue properties of cortical bone tissue. Bone Reports 2, 8-13. 111. Birkhold, A.I., Razi, H., Weinkamer, R., Duda, G.N., Checa, S., Willie, B.M., 2015. Monitoring in vivo (re)modeling: A computational approach using 4D microCT data to quantify bone surface movements. Bone 75, 210-221. 112. Lerebours, C., Thomas, C.D.L., Clement, J.G., Buenzli, P.R., Pivonka, P., 2015. The relationship between porosity and specific surface in human cortical bone is subject specific. Bone 72, 109-117. 113. Mann, K.A., Ayers, D.C., Werner, F.W., Nicoletta, R.J., Fortino, M.D., 1997. Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cement. J. Biomech. 30 (4), 339-346. 114. Bohner, M., Gasser, B., Baroud, G., Heini, P., 2003. Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure. Biomaterials 24, 2721-2730. 115. Teo, J.C.M., Si-Hoe, K.M., Keh, J.E.L., Teoh, S.H., 2006. Relationship between CT intensity, micro-architecture and mechanical properties of porcine vertebral cancellous bone. Clin. Biomech. 21, 235-244. 116. Walsh, M.P., Wijdicks, C.A., Parker, J.B., Hapa, O., LaPrade, R.F., 2009. A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction.Am. J. Sports Med. 37 (1), 160-167. 117. Feng, L., Chittenden, M., Schirer, J., Dickinson, M., Jasiuk, I., 2012. Mechanical properties of porcine femoral cortical bone measured by nanoindentation. J. Biomech. 45, 1775-1782. 118. Peric, M., Dumic-Cule, I., Grcevic, D., Matijasic, M., Verbanac, D., Paul, R., Grgurevic, L., Trkulja, V., Bagi, C.M., Vukicevic, S., 2015. The rational use of animal models on the evaluation of novel bone regenerative therapies. Bone 70, 73-86. 119. Proffen, B.L., McElfresh, M., Fleming, B.C., Murray, M.M., 2012. A comparative anatomical study of the human knee and six animal species. The Knee 19, 493-499. 120. Osterhoff, G., Loffler, S., Steinke, H., Feja, C., Josten, C., Hepp, P., 2011. Comparative anatomical measurements of osseous structures in the ovine and human knee. The Knee 18, 98-103. 121. Steinberg, E.L., Blumberg, N., Dekel, S., 2005. The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study. J. Biomech. 38, 63-68. 122. Kukla, C., Gaebler, C., Pichl, R.W., Prokesch, R., Heinze, G., Heinz, T., 2002. Predictive geometric factors in a standardized model of femoral neck fracture. Experimental study of cadaveric human femurs. Injury, Int. J. Care Injured 33, 427-433. 123. Maier, A., Regazzoni, P., 2000. Prevention of malunions in the rotation of complex fractures of the distal femur treated using the Dynamic Condylar Screw (DCS): An anatomical graphic analysis using computed tomography on cadaveric specimens. Injury, Int. J. Care Injured 31, S-B63-S-B69. 124. Kukla, C., Pichl, W., Prokesch, R., Jacyniak, W., Heinze, G., Gatterer, R., Heinz, T., 2001. Femoral neck fracture after removal of the standard gamma interlocking nail: a cadaveric study to determine factors influencing the biomechanical properties of the proximal femur. J. Biomech. 34, 1519-1526. 125. McNamara, B.P., Cristofolini, L., Toni, A., Taylor, D., 1994. Evaluation of experimental and finite element models of synthetic and cadaveric femora for pre-clinical design-analysis. Clin. Mat. 17, 131-140. 126. Pierre, M.A., Zurakowski, D., Nazarian, A., Hauser-Kara, D.A., Snyder, B.D., 2010. Assessment of the bilateral asymmetry of human femurs based on physical, densitometric, and structural rigidity characteristics. J. Biomech. 43, 2228-2236. 127. Sedlacek, R.C., O'Connor, D.O., Lozynsky, A.J., Harris, W.H., 1997. Assessment of the symmetry of bone strains in the proximal femoral medial cortex under load in bilateral pairs of cadaver femurs. J. Arthrop. 12 (6), 689-694. 128. Eberle, S., Gerber, C., von Oldenburg, G., Högel, F., Augat, P., 2010. A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro testing. Proc. IMechE Vol. 224 Part H: J. Engineering in Medicine, 1141-1152. 129. Simoes, J.A., Vaz, M.A., Blatcher, S., Taylor, M., 2000. Influence of head constraint and muscle forces on the strain distribution within the intact femur. Med. Eng. Phys. 22, 453-59. 130. Choi, J.K., Gardner, T.R., Yoon, E., Morrison, T.A., Macaulay, W.B., Geller, J.A., 2010. The effect of fixation technique on the stiffness of comminuted Vancouver B1 periprosthetic femur fractures. J. Arth. 25, 124-128. 131. Talbot, M., Zdero, R., Schemitsch, E.H., 2008. Cyclic loading of periprosthetic fracture fixation constructs. J. Trauma 64, 1308-1312. 132. Zdero, R., Bougherara, H., Dubov, A., Shah, S., Zalzal, P., Mahfud, A., Schemitsch, E.H., 2009. The effect of cortex thickness on intact femur biomechanics: a comparison of finite element analysis with synthetic femurs. Proc. IMechE Vol. 224 Part H: J. Engineering in Medicine, 831-40. 133. Shah, S., Kim, S.Y.R., Dubov, A., Schemitsch, E.H., Bougherara, H., Zdero, R., 2011. The biomechanics of plate fixation of periprosthetic femoral fractures neat the tip of a total hip implant: cables, screws, or both? Proc. IMechE Vol 225 Part H: J. Engineering in Medicine, 845-856. 134. Otani, T., Whiteside, L.A., White, S.E., 1993a. Strain distribution in the proximal femur with flexible composite and metallic femoral components under axial and torsional loads. J. Biomed. Mater. Res. 27, 575-585. 135. Heiner, A.D., 2008. Structural properties of fourth-generation composite femurs and tibias. J. Biomech. 41, 3282-84. 136. Panjabi, M.M., Trumble, T., Hult, J.E., Southwick, W.O., 1985. Effect of femoral stem length on stress raisers associated with revision hip arthroplasty. J. Orthop. Res. 3, 447-455. 137. Ebrahimi, H., Rabinovich, M., Vuleta, V., Zalcman, D., Shah, S., Dubov, A., Roy, K., Siddiqui, F.S., Schemitsch, E.H., Bougherara, H., Zdero, R., 2012. Biomechanical properties of an intact, injured, repaired, and healed femur: An experimental and computational study. Journal of the Mechanical Behavior of Biomedical Materials 16, 121–135. 138. Zdero, R., Shah, S., Mosli, M., Schemitsch, E.H., 2009. The effect of load application rate on the biomechanics of synthetic femurs. Proc. IMechE Vol 224 Part H: J. Engineering in Medicine, 599-605. 139. Stolk, J., Verdonschot, N., Cristofolini, L., Toni, A., Huiskes, R., 2002. Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests. J. Biomech. 35, 499-510. 140. Cordey, J., Borgeaud, M., Frankle, M., Harder, Y., Martinet, O., 1999. Loading model for the human femur taking the tension band effect of the ilio-tibial tract into account. Injury, Int. J. Care Injured 30, S-A26-S-A30. 141. Barker, R., Takahashi, T., Toms, A., Gregson, P., Kuiper, J.H., 2006. Reconstruction of femoral defects in revision hip surgery: risk of fracture and stem migration after impaction bone grafting. J. Bone Joint Surg. Br. 88, 832-836. 142. Wilson, D., Frei, H., Masri, B.A., Oxland, T.R., Duncan, C.P., 2005. A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fractures. Clin. Biomech. 20, 70-76. 143. Chong, A.C.M., Friis, E.A., Ballard, G.P., Czuwala, P.J., Cooke, F.W., 2007. Fatigue performance of composite analogue femur constructs under high activity loading. Annals of Biomedical Engineering 35 (7), 1196-1205. 144. Cristofolini, L., Erani, P., Savigni, P., Grupp, T., Thies, O., Viceconti, M., 2007. Increased long-term failure risk associated with excessively thin cement mantle in cemented hip arthroplasty: A comparative in vitro study. Clin. Biomech. 22, 410-421. 145. Ramos, A., Simões, J.A., 2009. The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses. 146. Sangiorgio, S.N., Longjohn, D.B., Dorr, L.D., Ebramzadeh, E., 2011. The influence of proximal stem geometry and surface finish on the fixation of a double-tapered cemented femoral stem. J. Biomech. 44, 22-27. 147. Ghosh, R., Gupta, S., 2014. Bone remodelling around cementless composite acetabular components: The effects of implant geometry and implant-bone interfacial conditions. J. Mech. Behav. Biomed. Mat. 32, 257-269. 148. Lin, B.A., Thomas, P., Spiezia, F., Loppini, M., Maffulli, N., 2013. Changes in daily physical activity before and after total hip arthroplasty. A pilot study using accelerometry. The Surgeon 11, 87-91. 149. Agnostini, V., Ganio, D., Facchin, K., Cane, L., Carneiro, M., Knaflitz, M., 2014. Gait parameters and muscle activation patterns at 3, 6, and 12 months after total hip arthroplasty. J. Arthrop. 29, 1265-1272. 150. Horstmann, T., Listringhaus, R., Haase, G-B., 2013. Changes in gait patterns and muscle activity following total hip arthroplasty: A six-month follow-up. Clin. Biomech. 28, 762-769. 151. Nishida, I., Maeda, M., Gordon, D., Robertson, E., Shirase, K., 2011. Development of an ergonomic musculoskeletal model to estimate muscle forces during vertical jumping. Procedia Eng. 13, 338-343. 152. Sverdlova, N.S., Witzel, U., 2010. Principles of determination and verification of muscle forces in the human musculoskeletal system: Muscle forces to minimise bending stress. J. Biomech. 43, 387-396. 153. Lloyd, D.G., Besier, T.F., 2003. An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo. J. Biomech. 36, 765-776. 154. Gagnon, D., Arjmand, N., Plamondon, A., Shirazi-Adl, A., Lariviere, C., 2011. An improved multi-joint EMG-assisted optimization approach to estimate joint and muscle forces in a musculoskeletal model of the lumbar spine. J. Biomech. 44, 1521-1529. 155. Augat, P., Penzkofer, R., Nolte, A., Maier, M., Panzer, S., Oldenburg, G., Pueschl, K., Simon, U., Buhren, V., 2008. Interfragmentary movement in diaphyseal tibia fractures fixed with locked intramedullary nails. J. Orhtop. Trauma 22, 30-36. 156. Milgrom, C., Finestone, A., Hamel, A., Mandes, V., Burr, D., Sharkey, N., 2003. A comparison of bone strain measurements at anatomically relevant sites using surface gauges versus strain gauged bone staples. J. Biomech. 37, 947-952. 157. Verhulp, E., van Rietbergen, B., Huiskes, R., 2003. A three-dimensional digital image correlation technique for strain measurements in microstructures. J. Biomech. 37, 1313-1320. 158. Yang, P.F., Sanno, M., Bruggemann, G.P., Rittweger, J., 2012. Evaluation of the performance of a motion capture system for small displacement recording and a discussion for its application potential in bone deformation in vivo measurements. Proc. IMechE Vol 226(11) Part H: J. Engineering in Medicine, 838-847. 159. Troy, K.L., Brown, T.D., Conzemius, M.G., 2009. Contact stress distributions on the femoral head of the emu. J. Biomech. 42, 2495–2500. 160. Senalp, A.Z., Kayabasi, O., Kurtaran, H., 2007. Static, dynamic and fatigue behavior of newly designed stem shapes for hip prosthesis using finite element analysis. Mat. Des. 28, 1577-1583. 161. Kayabasi, O., Ekici, B., 2007. The effects of static, dynamic and fatigue behavior on three-dimensional shape optimization of hip prosthesis by finite element method. Mat. Des. 28, 2269-2277. 162. Jeffers, J.R.T., Browne, M., Lennon, A.B., Prendergast, P.J., 163. Mihalko, W.M., Beaudoin, A.J., Cardea, J.A., Krause, W.R., 1992. Finite-element modelling of femoral shaft fracture fixation techniques post total hip arthroplasty. J. Boimech. 25, 469. 164. Mann, K.A., Bartel, D.L., Wright, T.M., Burstein, A.H., 1995. Coulomb frictional interfaces in modeling cemented total hip replacements: a more realistic model. J. Biomechanics 28, 1067-1078. 165. Spiers, A.D., Heller, M.O., Taylor, W.R., Duda, G.N., Perka, C., 2007. Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implant. Clin. Biomech. 22, 431-439. 166. Cheung, G., Zalzal, P., Bhandari, M., Spelt, J.K., Papini, M., 2004. Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading. Medical Engineering & Physics 26, 93-108. 167. Gefen, A., 2002. Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws. Med. Biol. Eng. Comput. 40, 311-322. 168. Norman, T.L., Thyagarajan, G., Saligrama, V.C., Gruen, T.A., Blaha, J.D., 2001. Stem surface roughness alters creep induced subsidence and 'taper-lock' in a cemented femoral hip prosthesis. J. Biomech. 34, 1325-1333. 169. Chen, D.W., Lin, C.L, Hu, C.C., Wu, J.W., Lee, M.S., 2012. Finite element analysis of different repair methods of Vancouver B1 periprosthetic fractures after total hip arthroplasty. Injury, 1-5. 170. Nuno, N., Groppetti, R., Senin, N., 2006. Static coefficient of friction between stainless steel and PMMA used in cemented hip and knee implants. Clin. Biomech. 21, 956-962. 171. Köbel, R., Bergmann, G., Boenick, U., 1976. Mechanical engineering of the cement-bone bond. In: Engineering in Medicine 347-357. Springer-Verlag, New York. 172. Bean, D.J., Convery, F.R., Woo, S.L.Y., Lieber, R.L., 1987. Regional variation in shear strength of the bone-polymethylmethacrylate interface. J. Arthrop. 2 (4), 293-298. 173. Ryf CR, Arraf J. Postoperative fracture treatment: general considerations. In: Ruedi TP, Buckley RE, Moran CG, editors. AO principal of fracture management. 2nd ed. Davos: AO Publishing; 2007. p. 447. 174. National Instruments, 2014. Measuring Strain with Strain Gages. Available at www.ni.com/white-paper/3642/en [Accessed March 2015] 175. Chong, A.C.M., Miller, F., Buxton, M., Friis, E.A., 2007. Fracture toughness and fatigue crack propagation rate of short fiber reinforced epoxy composites for analogue cortical bone. Journal of Biomechanical Engineering 129, 487-493. 176. Anderson, A.E., Ellis, B.J., Weiss, J.A., 2007. Verification, validation and sensitivity studies in computational biomechanics. Computer Methods in Biomechanics and Biomedical Engineering 10 (3), 171-184. 177. Oberkampf, W.L., Trucano, T.G., Hirsch, C., 2002. Verification, validation, and predictive capability on computational engineering and physics. Foundations for Verification and Validation in the 21st Century Workshop, Johns Hopkins University, 2002. 178. Viceconti, M., Olsen, S., Burton, K., 2005. Extracting clinically relevant data from finite element simulations. Clinical Biomechanics 20, 451-454. 179. Blottner, F.G., 1990. Accurate Navier-Stokes results for the hypersonic flow over a spherical nosetip. J. Spacecraft 27 (2). 180. Boehm, B.W., 1981. Software engineering economics. Prentice Hall, Englewood Cliffs, New Jersey. 181. Jones, A.C., Wilcox, R.K., 2008. Finite element analysis of the spine: Towards a framework of verification, validation and sensitivity analysis. Medical Engineering and Physics 30, 1287-1304. 182. Sargent, R.G., 2011. Verification and validation of simulation models. Proceeding of the 2011 Winter Simulation Conference, 183-198. 183. Henninger, H.B., Reese, S.P., Anderson, A.E., Weiss, J.A., 2010. Validation of computational models in biomechanics. Proc. Inst. Mech. Eng. H 224 (7), 801-812. 184. Desmarais-Trépanier C. femur_sawbone.zip, From the Biomechanics European Laboratory _BEL_, Finite Element Mesh Repository, http://www.tecno.ior.it/VRLAB. 2009. 185. Benham, P.P., Crawford, R.J., Armstrong, C.G., 1996. Mechanics of Engineering Materials. Prentice Hall, Singapore. 186. Kusy, R.P., 1978. Characterization of self-curing acrylic bone cements. Journal of Biomedical Materials Research 12, 271-305. 187. De Wijn, J.R., Slooff, T.J.J.H., Driessens, F.C.M., 1975. Characterization of bone cements. Acta Orthop. Scand. 46. 38-51. 188. Holm, N.J., 1977. The modulus of elasticity and flexural strength of some acrylic bone cements. Acta Orthop. Scand. 48, 436-442. 189. Davies, J.P., O'Conner, D.O., Greer, J.A., Harris, W.H., 1987. Comparison of the mechanical properties of Simplex P, Zimmer Regular, and LVC bone cements. Journal of Biomedical Materials Research 21, 719-730. 190. Dunne, N.J., Orr, J.F., 2001. Influence of mixing techniques on the physical properties of acrylic bone cement. Biomaterials 22, 1819-1826. 191. Dunne, N.J., Orr, J.F., Mushipe, M.T., Eveleigh, R.J., 2003. The relationship between porosity and fatigue characteristics of bone cements. Biomaterials 24, 239-245. 192. Wilkinson, J.M., Eveleigh, R., Hamer, A.J., Milne, A., Miles, A.W., Stockley, I., 2000. Effect of mixing technique on the properties of acrylic bone-cement. The Journal of Arthroplasty 15 (5), 663-667. 193. Gilroy, D., Younge, A.M., Phillips, A.T.M., Wheel, M., Riches, P.E., 2014. Characterisation and Validation of Sawbones Artificial Composite Femur Material. 7th World Congress of Biomechanics. 194. Abaqus, 2012. ABAQUS 6.12 Documentation. Dassault Systèmes, Providence, RI, USA. 195. Zdero, R., Olsen, M., Bougherara, H., Schemitsch, E.H., 2008. Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis. Proc. IMechE Vol. 222 Part H: J. Engineering in Medicine, 1175-1183. 196. Wieding, J., Souffrant, R., Fritsche, A., Mittelmeier, W., Bader, R., 2012. Finite element analysis of osteosynthesis screw fixation in the bone stock: an appropriate method for automatic screw modelling. PLoS ONE 7(3), 1-10. 197. Liu, G.R., Quek, S.S., 2013. The finite element method: a practical course. Elsevier, Oxford. 198. Litchman, H.M., Richman, M.H., Warman, M., Mitchell, J., 1978. Improvement of the mechanical properties of polymethylmethacrylate by graphite fiber reinforcement. Trans. Orthop. Res. Soc., 2, 86. 199. Saha, S., Warman, M.L., 1979. Compressive and shear properties of graphite fiber reinforced bone cement. Orthop. Trans., 3, 169. 200. Saha, S., Warman, M.L., 1979. Improved mechanical properties of graphite fiber reinforced polymethylmethacrylate. Trans. 17th Int. Biomater. Symp. and 5th Ann. Meeting SOC. Biomater., 3, 174. 201. Heller, M.O., Bergmann, G., Deuretzbacher, G., Dürselen, L., Pohl, M., Claes, L., Haas, N.P., Duda, G.N., 2001. Musculo-skeletal loading conditions at the hip during walking and stair climbing. J. Biomech. 34, 883-893. 202. Retpen, J.B., Jensen, J.S., 1993. Risk factors for recurrent aseptic loosening of the femoral component after cemented revision. J. Arthroplasty 8 (5), 471-478. 203. Blain, H., Chavassieux, P., Portero-Muzy, N., Bonnel, F., Canovas, F., Chammas, M., Maury, P., Delmas, P.D., 2008. Cortical and trabecular bone distribution in the femoral neck in osteoporosis and osteoarthritis. Bone 43, 862-868. 204. Karrholm, J., Borssen, B., Lowenhielm, G., Snorrason, F., 1994. Does early micromotion of femoral stem prostheses matter? J. Bone Joint Surg. (Br) 76-B, 912-7. 205. Alfaro-Adrian, J., Gill, H.S., Murray, D.W., 2001. Should total hip arthroplasty femoral components be designed to subside? J. Arthrop. 16 (5), 598-606."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.655253"]},{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["Latta Fellowship","WT 088908/Z/09/Z","Collaboration with Leeds Musculoskeletal Biomedical Research Unit","Provided surgical components"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/9311/1/Checked_Corrected_Final_Thesis_LeeEtchels.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Periprosthetic femoral fractures (PFF) are a complication associated with total hip arthroplasty patients that can be both traumatic and challenging to treat. With the increasing age of the population and increasing prevalence of hip replacement surgery periprosthetic femoral fractures are expected to occur more frequently in the future. The most common type of PFF is the Vancouver Type B fracture that occurs near the tip of the original prosthesis. These fractures can be complicated further by loosening of the primary femoral stem (Type B2 fractures) and poor bone stock (Type B3 fractures). Clinical failures and unclear optimal treatment recommendations for many fractures suggest that further investigation is required. This study mechanically tested experimental specimens representing the cemented long stem revision treatment of a Type B2 PFF at a range of loading orientations to evaluate their biomechanical response. From these specimens the axial stiffness, medial axial strain, distal lateral axial strain, and relative fracture movement were recorded under semi-physiological loading. These experimental results were also used to validate computational, finite element (FE), models of long stem PFF treatment. The computational models were shown to achieve reasonable agreement with the experimental data, such that they could be used to investigate a wider range of clinical scenarios. The FE models were then used to compare the relative effects of different cement mantle geometries, fracture location, fracture bridging distance, fracture angle, revision femoral stem length and osteoporosis. The specific location and angle of the fracture appeared to have an effect on the bending response of the femur and the optimal treatment. Long stem revision treatment however seemed to be suitable for achieving stability around an unstable fracture and it may be possible to counter-act the increased risk of fixation failure in osteoporotic patients by selecting a longer bridging distance."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Optimisation Of Fixation Methods For Vancouver Type B2 And B3 Periprosthetic Femoral Fracture Treatment"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wilcox, Ruth","Jones, Alison","Tsiridis, Eleftherios","Jin, Zhongmin"],"dc:contributor.sponsor":["British Orthopaedic Association","Wellcome Trust and EPSRC","National Institute for Health Research","Stryker UK"],"dc:creator":["Etchels, Lee William"],"dc:date":["2014-10"],"dc:date.issued":["2014-10"],"dc:description.abstract":["Periprosthetic femoral fractures (PFF) are a complication associated with total hip arthroplasty patients that can be both traumatic and challenging to treat. With the increasing age of the population and increasing prevalence of hip replacement surgery periprosthetic femoral fractures are expected to occur more frequently in the future. The most common type of PFF is the Vancouver Type B fracture that occurs near the tip of the original prosthesis. These fractures can be complicated further by loosening of the primary femoral stem (Type B2 fractures) and poor bone stock (Type B3 fractures). Clinical failures and unclear optimal treatment recommendations for many fractures suggest that further investigation is required. This study mechanically tested experimental specimens representing the cemented long stem revision treatment of a Type B2 PFF at a range of loading orientations to evaluate their biomechanical response. From these specimens the axial stiffness, medial axial strain, distal lateral axial strain, and relative fracture movement were recorded under semi-physiological loading. These experimental results were also used to validate computational, finite element (FE), models of long stem PFF treatment. The computational models were shown to achieve reasonable agreement with the experimental data, such that they could be used to investigate a wider range of clinical scenarios. The FE models were then used to compare the relative effects of different cement mantle geometries, fracture location, fracture bridging distance, fracture angle, revision femoral stem length and osteoporosis. The specific location and angle of the fracture appeared to have an effect on the bending response of the femur and the optimal treatment. Long stem revision treatment however seemed to be suitable for achieving stability around an unstable fracture and it may be possible to counter-act the increased risk of fixation failure in osteoporotic patients by selecting a longer bridging distance."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.655253"],"dc:identifier.grantnumber":["Latta Fellowship","WT 088908/Z/09/Z","Collaboration with Leeds Musculoskeletal Biomedical Research Unit","Provided surgical components"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/9311/1/Checked_Corrected_Final_Thesis_LeeEtchels.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["Institute of Medical and Biological Engineering (iMBE)(Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/9311/"],"dc:relation.references":["1. National Joint Registry, 2013. Executive summary: public and patient guide to the NJR's 10th annual report 2013. Hemel Hempstead: NJR. Available at www.njrcentre.org.uk [Accessed May 2014]. 2. Tsiridis, E., Pavlou, G., Venkatesh, R., Bobak, P., Gie, G., 2009. Periprosthetic femoral fractures around hip arthroplasty: Current concepts in their management. Hip International 19 no. 2, 75-86. 3. Nho, S.J., Kymes, S.M., Callaghan, J.J., Felson, D.T., 2013. The burden of hip osteoarthritis in the United States: Epidemiologic and economic considerations. J. Am. Acad. Orthop. Surg. 21, S1-6. 4. Lever, J.P., Zdero, R., Nousiainen, M.T., Waddell, J.P., Schemitsch, E.H., 2010. The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty. Journal of Orthopaedic Surgery and Research 5, 45. 5. Chen, G., Schmutz, B., Wullschleger, M., Pearcy, M.J., Schuetz, M.A., 2009. Computational investigations of mechanical failures of internal plate fixation. Proc. IMechE Vol. 224 Part H: J. Engineering in Medicine, 119-126. 6. Lindahl H, Malchau H, Oden A, et al. Risk factors for failure after treatment of a periprosthetic fracture of the femur. J Bone Joint Surg Br 2006;88:26. 7. Buttaro MA, Farfalli G, Paredes Nunez M, et al. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures. J Bone Joint Surg Am 2007;89:1964. 8. Graham SM, Moazen M, Leonidou A, et al. Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 cases. J Orthop Sci 18, 426-436. 9. Schmotzer, H., Tchejeyan, G.H., Dall, D.M., 1996. Surgical management of intra-and postoperative fractures of the femur about the tip of the stem in total hip arthroplasty. J. Arthroplasty 11, 709-717. 10. Zdero, R., Walker, R., Waddell, J.P., Schemitsch, E.H., 2008. Biomechanical evaluation of periprosthetic femoral fracture fixation. J. Bone Joint Surg. Am. 90, 1068-1077. 11. Tsiridis, E., Haddad, F.S., Gie, G.A., 2003. Dall-Miles plates for periprosthetic femoral fractures a critical review of 16 cases. Injury, Int. J. Care Injured 34, 107-110. 12. Sommers, M.B., Fitzpatrick, D.C., Madey, S.M., Zanderschulp, C.V., Bottlang, M., 2007. A surrogate long-bone model with osteoporotic material properties for biomechanical testing of fracture implants. J. Biomech. 40, 3297-3304. 13. Moazen, M., Jones, A.C., Jin, Z., Wilcox, R.K., 2011. Periprosthetic fracture fixation of the femur following total hip arthroplasty: A review of biomechanical testing. Clin. Biomech. 26 (1), 13-22. 14. Cristofolini, L., Viceconti, M., Cappello, A., Toni, A., 1996. Mechanical validation of whole bone composite femur models. J. Biomechanics, Vol. 29, No. 4, 525-535. 15. Cristofolini, L., Viceconti, M., 2000. Mechanical validation of whole bone composite tibia models. J. Biomech. 33, 279-288. 16. Mak, J.H., 2013. Optimisation of locking plate fixation methods for periprosthetic fractures. PhD thesis. University of Leeds. 17. Briant-Evans, T.W., Veeramootoo, D., Tsiridis, T., Hubble, M.J., 2009. Cement-in-cement stem revision for Vancouver type B periprosthetic femoral fractures after total hip arthroplasty. Acta Orthopaedica 80 (5), 548-552. 18. Mak, J.H., Moazen, M., Jones, A.C., Jin, Z., Tsiridis, E., Wilcox, R.K., 2012. J. Bone Joint Surg. Br. 94-B (74). 19. Moazen, M., Mak, J.H., Etchels, L.W., Jin, Z., Wilcox, R.K., Jones, A.C., Tsiridis, E., 2014. Periprosthetic femoral fracture - a biomechanical comparison between Vancouver Type B1 and B2 fixation methods. J. Arthroplasty 29, 495-500. 20. Moazen, M., Mak, J.H., Etchels, L.W., Jin, Z., Wilcox, R.K., Jones, A.C., Tsiridis, E., 2013. The effect of fracture stability on the performance of locking plate fixation in periprosthetic femoral fractures. J. Arthroplasty 28, 1589-1595. 21. Moazen, M., Jones, A.C., Leonidou, A., Jin, Z., Wilcox, R.K., Tsiridis, E., 2012. Rigid versus flexible plate fixation for periprosthetic femoral fracture - computer modelling of a clinical case. Med. Eng. Phys. 34, 1041-1048. 22. Moazen, M., Mak, J.H., Jones, A.C., Jin, Z., Wilcox, R.K., Tsiridis, E., 2013. Evaluation of a new approach for modelling the screw-bone interface in a locking plate fixation:a corroboration study. Proc. IMechE Part H: J. Engineering in Medicine 227(7), 746-756. 23. Moazen, M., Mak, J.H., Etchels, L.W., Jones, A.C., Jin, Z., Wilcox, R.K., Tsiridis, E., 2013. Why do periprosthetic femoral fracture fixations fail - a biomechanical investigation. Bone & Joint Journal Orthopaedic Proceedings Supplement 95 (16), 62. 24. Moazen, M., Jones, A.C., Mak, J., Jin, Z., Wilcox, R.K., Tsiridis, E., 2011. The computational evaluation of a locking plate fixation - locking versus far cortical screws. Proceedings of the ASME 2011 Summer Bioengineering Conference. 25. Cox, B.D., 2006.Measurement of bone cement properties using self-sensing techniques. PhD thesis, University of Leeds. 26. Gie, G.A., Linder, L., Ling, R.S.M., Simon, J-P., Slooff, T.J.J.H., Timperley, A.J., 1993. Impacted cancellous allografts and cement for revision total hip arthroplasty. J. Bone Joint Surg. (Br) 75-B, 14-21. 27. Kusakabe, H., Sakamaki, T., Nihei, K., Oyama, Y., Yanagimoto, S., Ichimiya, M., Kimura, J., Toyama, Y., 2004. Osseointegration of a hydroxyapatite-coated multilayered mesh stem. Biomaterials 25, 2957-2969. 28. Lakstein, D., Kopelovitch, W., Barkay, Z., Bahaa, M., Hendel, D., Eliaz, N., 2009. Enhanced osseiointegration of grit-blasted, NaOH-treated and electrochemically hydroxyapatite-coated Ti-6Al-4V implants in rabbits. Acta Biomaterialia 5, 2258-2269. 29. Kelley, S.S., 1994. Periprosthetic femoral fractures. J. Am. Acad. Orthop. Surg. 2, 164-172. 30. Beals, R.K., Tower, S.S., 1996. Periprosthetic fractures of the femur: An analysis of 93 fractures. Clin. Orthop. Relat. Res. 327, 238-246. 31. Corten, K., Vanrykel, F., Bellemans, J., Reynders Frederix, P., Simon, J.-P., Broos, P.L.O., 2009. An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component. J. Bone Joint Surg. (Br) 91-B (11), 1424-1430. 32. Masri, B.A, Meek, R.M.D, Duncan, C.P., 2004. Periprosthetic fractures evaluation and treatment. Clin. Orthop 420, 80-95. 33. Adolphson, P., Jonsson, U., Kalen, R., 1987. Fractures of the ipsilateral femur after total hip arthroplasty. Arch. Orthop. Trauma Surg. 106, 353-357. 34. Cooke, P.H., Newman, J.H., 1988. Fractures of the femur in relation to cemented hip prostheses. J. Bone Joint Surg. (Br) 70-B, 386-9. 35. Johansson, J.E., McBroom, R., Barrington, T.W., Hunter, G.A., 1981. Fracture of the ipsilateral femur in patients with total hip replacement. J. Bone Joint Surg. (Am) 63 (9), 1435-1442. 36. Kavanagh, B.F.,1992. Femoral fractures associated with total hip arthroplasty. Orthop. Clin. North Am. 23, 249-257. 37. Mallory, T.H., Kraus, T.J., Vaughn, B.K., 1989. Intraoperative femoral fractures associated with cementless total hip arthroplasty. Orthopedics 12, 231-239. 38. Schwartz, J.T., Mayer, J.G., Engh, C.A., 1989. Femoral fracture during non-cemented total hip arthroplasty. J. Bone Joint Surg. (Am) 71 (8), 1135-1142. 39. Stuchin, S.A., 1990. Femoral shaft fracture in porous and press-fit total hip arthroplasty. Orthop. Rev. 19 (2), 153-9. 40. Roffman, M., Mendes, D.G., 1989. Fracture of the femur after total hip arthroplasty. Orthopedics 12 (8), 1067-1070). 41. Duncan, C.P., Masri, B.A., 1995. Fractures of the femur after hip replacement. Instr. Course Lect. 45, 293-304. 42. Kamineni, S., Vindlacheruvu, R., Ware, H.E., 1999. Peri-prosthetic femoral shaft fractures treated with plate and cable fixation. Injury Int. J. Care Injured 30, 261-268. 43. Grammatopoulos, G., Pandit, H., Kambouroglou, G., Deakin, M., Gundle, R., McLardy-Smith, P., Taylor, A., Murray, D., 2011. A unique peri-prosthetic fracture pattern in well fixed femoral stems with polished, tapered, collarless, design of total hip replacement. Injury Int. J. Care Injured 42 (11), 1271-6. 44. O'Shea, K., Kutty, S., Quinlan, J.F., Brady, O.H., Mulcahy, D., 2005. The use of uncemented extensively porous-coated femoral components in the management of Vancouver B2 and B3 periprosthetic femoral fractures. J. Bone Joint Surg. (Br) 87-B (12), 1617-21. 45. Leonidou, A., Moazen, M., Lepetsos, P., Graham, S.M., Macheras, G.A., Tsiridis, E., 2015. The biomechanical effect of bone quality and fracture topography on locking plate fixation in periprosthetic femoral fractures. Injury Int. J. Care Injured 46, 213-217. 46. Yoshida, Y., Osaka, S., Kojima, T., Taniguchi, M., Osaka, E., Tokuhashi, Y., 2012. Revision of tumor prosthesis of the knee joint. Eur. J. Orthop. Surg. Traumatol. 22, 387-394. 47. Cannon, S.R., 1997. Massive prostheses for malignant bone tumours of the limbs. Eu. Instr. Course Lect. 3. 48. Springer, B.D., Berry, D.J., Lewallen, D.G., 2003. Treatment of periprosthetic femoral fractures following total hip arthroplasty with femoral component revision. J. Bone Joint Surg. Am. 85, 2156-2162. 49. Venu, K.M., Koka, R., Garikipati, R., Shenava, Y., Madhu, T.S., 2001. Dall-Miles cable and plate fixation for the treatment of peri-prosthetic femoral fractures - analysis of results in 13 cases. Injury, Int. J. Care Injured 32, 395-400. 50. Tadross, T.S.F., Nanu, A.M., Buchanan, M.J., Checketts, R.G., 2000. Dall-Miles plating for periprosthetic B1 fractures of the femur. J. Arth. 15 (1), 47-51. 51. Lewallen, D.G., Berry, D.J., 1997. Periprosthetic fracture of the femur after total hip arthroplasty. J. Bone Joint Surg. (Am) 79-A (12), 1881-1890. 52. Oh, J.K., Shau, D., Ahn, Y.H., Lee, S.J., Tsutsumi, S., Hwang, J.H., Jung, D.Y., Perren, S.M., Oh, C.W., 2009. Effect of fracture gap on stability of compression plate fixation: a finite element study. J. Orthop. Res. 28 (4), 462-7. 53. Mann, K.A., Ayers, D.C., Damron, T.A., 1997. Effects of stem length on mechanics of the femoral hip component after cemented revision. J. Orthop. Res. 15, 62-68. 54. Pellicci, P.M., Wilson Jr, P.D., Sledge, C.B., Salvati, E.A., Ranawat, C.S., Poss, R., Callaghan, J.J., 1985. Long-term results of revision total hip replacement. A follow up report. J. Bone Joint Surg. (Am) 67 (4), 513-516. 55. Froberg, L., Troelsen, A., Brix, M., 2012. Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis. Acta Orthopaedica 83 (6), 648-652. 56. Otani, T., Whiteside, L.A., White, S.E., 1993b. Effect of femoral component material properties on cementless fixation in total hip arthroplasty. J. Arthrop. 8, 67-74. 57. Tsiridis, E., Narvani, A.A., Haddad, F.S., Timperley, J.A., Gie, G.A., 2004. Impaction femoral allografting and cemented revision for periprosthetic femoral fractures. J Bone Joint Surg. (Br) 96-B, 1124-32. 58. Moreland, J.R., Bernstein, M.L., 1995. Femoral revision hip arthroplasty with uncemented, porous-coated stems. Clin. Orthop. Relat. Res. 319, 141-150. 59. Huiskes, R., Weinans, H., Rietbergen, B.V., 1992. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin. Orthop. Relat. Res. 274, 124-134. 60. Marsland, D., Mears, S.C., 2012. A review of periprosthetic femoral fractures associated with total hip arthroplasty. Geriatr. Orthop. Surg. Rehabil. 2012, 3(3), 107-120. 61. Byrne, D.P., Mulhall, K.J., Baker, J.F., 2010. Anatomy & Biomechanics of the hip. The Open Sports Medicine Journal 4, 51-57. 62. Schuenke, M., Schulte, E., Schumacher, U., 2006. THIEME Atlas of Anatomy. In: Ross L, Lamperti E, Eds. General Anatomy of the Musculoskeletal System. Thieme, New York. 63. Marieb, E.N. Human Anatomy and Physiology. 2004. 64. Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., Duda, G.N., 2001. Hip contact forces and gait patterns from routine activities. J. Biomech. 34, 859-871. 65. Rohrle, H., Scholten, R., Sigolotto, C., Sollbach, W., Kellner, H., 1984. Joint forces in the human pelvis-leg skeleton during walking. J. Biomech. 17 (6), 409-424. 66. Thornton-Trump, A.B., Daher, R., 1975. The prediction of reaction forces from gait data. J. Biomech. 8, 173-178. 67. Paul, J.P., 1974. Techniques of gait analysis. Proc. Roy. Soc. Med. 67, 401-404. 68. Brand, R.A., Pedersen, D.R., Davy, D.T., Kotzar, G.M., Heiple, K.G., Goldberg, V.M., 1994. Comparison of hip force calculations and measurements in the same patient. J. Arthrop. 9 (1), 45-51. 69. Aamodt, A., Lund-Larson, J., Eine, J., Anderson, E., Benum, P., Schnell Husby, O., 1997. In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur. J. Orthop. Res. 15, 927-931. 70. Genda, E., Iwasaki, N., Li, G., MacWilliams, A., Barrance, P.J., Chao, E.Y.S, 2001. Normal hip joint contact pressure distribution in single-leg standing - effect of gender and anatomic parameters. J. Biomech. 34, 895-905. 71. Seireg, A., Arvikar, R.J., 1975. The prediction of muscular load sharing and joint forces in the lower extremities during walking. J. Biomech. 8, 89-102. 72. Paul, J.P., 1967. Forces at the human hip joint. PhD Thesis, University of Glasgow. 73. Crowninshield, R.D., Johnston, R.C., Andrews, J.G., Brand, R.A., 1978. A biomechanical investigation of the human hip. J. Biomech. 11, 75-85. 74. Horak, F.B., Henry, S.M., Shumway-Cook, A., 1997. Postural perturbations: New insights for treatment of balance disorders. Phys. Ther. 77, 517-533. 75. Johnson, F., Leitl, S., Waugh, W., 1980. The distribution of load across the knee, a comparison of static and dynamic measurements. J. Bone Joint Surg (Br) 62-B (3), 346-349. 76. Hagstedt, B., Norman, O., Olsson, T.H., Tjornstrand, B., 1980. Technical accuracy in high tibial osteotomy for gonarthrosis. Acta Orthop. Scand. 51, 963-970. 77. Koshino, T., Tsuchiya, K., 1979. The effect of high tibial osteotomy on osteoarthritis of the knee. Int. Orthop. 3, 37-45. 78. Yang, N.H., Canavan, P.K., Nayeb-Hahemi, H., 2010. The effect of the frontal plane tibiofemoral angle and varus knee moment on the contact stress and strain at the knee cartilage. J. Applied Biomechanics 26, 432-443. 79. Karachalios, T.H., Sarangi, P.P., Newman, J.H., 1994. Severe varus and valgus deformities treated by total knee arthroplasty. J. Bone Joint Surg. (Br) 76-B (6), 938-942. 80. Lotz, J., Gerhart, T.,N., Hayes, W.C., 1991. Mechanical properties of metaphyseal bone in the proximal femur. J. Biomech. 24 (5), 317-329. 81. Carter, D.R., Hayes, W.C., 1976. Fatigue life of compact bone - I Effects of stress, amplitude, temperature and density. J. Biomech. 9, 27-34. 82. Rho, J-Y, Kuhn-Spearing, L., Zioupos, P., 1998. Mechanical properties and the hierarchical structure of bone. Med. Eng. & Phys. 20, 92-102. 83. Shahar, R., Zaslansky, P., Barak, M., Friesem, A.A., Currey, J.D., Weiner, S., 2007. Anisotropic Poisson's ratio and compression modulus of cortical bone determined y speckle interferometry. J. Biomech. 40, 252-264. 84. Reilly, D.T., Burstein, A.H., 1975. The elastic and ultimate properties of compact bone tissue. J. Biomech. 8 (6), 393-396. 85. Morgan, E.F., Bayraktar, H.H., Keaveny, T.M., 2003. Trabecular bone modulus-density relationships depend on anatomic site. J. Biomech. 36, 897-904. 86. Morgan, E.F., Keaveny, T.M., 2001. Dependence of yield strain of human trabecular bone on anatomic site. J. Biomech. 34, 569-577. 87. Bayraktar, H.H., Morgan, E.F., Niebur, G.L., Morris, G.E., Wong, E.K., Keaveny, T.M., 2004. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. J. Biomech. 37, 27-35. 88. Reilly, D.T., Burstein, A.H., Frankel, V.H., 1974. The elastic modulus for bone. J. Biomech. 7, 271-275. 89. Rho, J-Y., Ashman, R.B., Turner, C.H., 1993. Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements. J. Biomech. 26 (2), 111-119. 90. Turner, C.H., Rho, J., Takano, Y., Tsui, T.Y., Pharr, G.M., 1999. The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques. J. Biomech. 32, 437-441. 91. Berteau, J-P., Baron, C., Pithioux, M., Launay, F., Chabrand, P., Lasaygues, P., 2014. In vitro ultrasonic and mechanic characterization of the modulus of elasticity of children cortical bone. Ultrasonics 54, 1270-1276. 92. Abdel-Wahab, A.A., Alam, K., Silberschmidt, V.V., 2011. Analysis of anisotropic viscoelastoplastic properties of cortical bone tissues. J. Mech. Behav. Biomed. Mater. 4, 807-820. 93. Johnson, T.P.M., Socrate, S., Boyce, M.C., 2010. A viscoelastic, viscoplastic model of cortical bone valid at low and high strain rates. Acta Biomaterialia 6, 4073-4080. 94. Brown, S.J., Pollintine, P., Powell, D.E., Davie, M.W.J., Sharp, C.A., 2002. Regional differences in mechanical and material properties of femoral head cancellous bone in health and osteoarthritis. Calcif. Tissue Int. 71, 227-234. 95. Linde, F., Hvid, I., Pongsoipetch, B., 1989. Energy absorptive properties of human trabecular bone specimens during axial compression. J. Orthop. Res. 7, 432-439. 96. Homminga, J., McCreadie, B.R., Ciarelli, T.E., Weinans, H., Goldstein, A., Huiskes, R., 2002. Cancellous bone mechanical properties from normals and patients with hip fractures differ on the structural level, not on the bone hard tissue level. Bone 30 (5), 759-764. 97. Chevalier, Y., Pahr, D., Allmer, H., Charlebois, M., Zysset, P., 2007. Validation of a voxel-based FE method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation. J. Biomech. 40, 3333-3340. 98. Rho, J-Y., Tsui, T.Y., Pharr, G.M., 1997. Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. Biomaterials 18, 1325-1330. 99. Ulrich, D., Hildebrand, T., Van Rietbergen, B., Ruegsegger, P., 1997. The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing. Stud. Health Technol. Inform. 40, 97-112. 100. Zysset, P.K., Guo, X. E., Hoffler, C.E., Moore, K.E., Goldstein, S.A., 1999. Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur. J. Biomech. 32, 1005-1012. 101. Ninomi, M., 2002. Recent materials for biomedical applications. Metallurgical and Materials Transactions A 33A, 477-486. 102. Hermawan, H., Ramdan, D., Djuansjah, J.R.P., 2011. Metals for Biomedical Applications, Biomedical Engineering - From Theory to Applications, Prof. Reza Fazel (Ed.), ISBN: 978-953-307-637-9, InTech, Available from: http://www.intechopen.com/books/biomedical-engineering-from-theory-toapplications/metals-for-biomedical-applications. 103. Uhthoff, H.K., Poitras, P., Backman, D.S., 2005. Internal plate fixation of fractures: Short history and recent developments. J. Orthop. Sci. 11, 118-126. 104. Claes, L.E., Cunningham, J.L., 2009. Monitoring the mechanical properties of healing bone. Clin. Orthop. Relat. Res. 467, 1964-1971. 105. Perren, S.M., 2002. Evolution of the internal fixation of long bone fractures. J. Bone Joint Surg. [Br] 84-B, 1093-1110. 106. Perren, S.M., Cordey, J., Rahn, B.A., Gautier, E., Schneider, E., 1988. Early temporary porosis of bone induced by internal fixation implants. Clin. Orthop. Relat. Res. 232, 139-51. 107. Berhmann, G., Graichen, F., Rohlmann, A., 1993. Hip joint loading during walking and running, measured in two patients. J. Biomech. 26 (8), 969-990. 108. Sawbones, 2014. Biomechanical Test Materials 2014. Available at www.sawbones.com [Accessed January 2015]. 109. Basso, T., Klaksvik, J., Syversen, U., Foss, O.A., 2014. A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures. J. Biomech. 47, 3898-3902. 110. Brock, G.R., Chen, J.T., Ingraffea, A.R., MacLeay, J., Pluhar, G.E., Boskey, A.L., van der Meulen, M.C.H., 2015. The effect of osteoporosis treatments on fatigue properties of cortical bone tissue. Bone Reports 2, 8-13. 111. Birkhold, A.I., Razi, H., Weinkamer, R., Duda, G.N., Checa, S., Willie, B.M., 2015. Monitoring in vivo (re)modeling: A computational approach using 4D microCT data to quantify bone surface movements. Bone 75, 210-221. 112. Lerebours, C., Thomas, C.D.L., Clement, J.G., Buenzli, P.R., Pivonka, P., 2015. The relationship between porosity and specific surface in human cortical bone is subject specific. Bone 72, 109-117. 113. Mann, K.A., Ayers, D.C., Werner, F.W., Nicoletta, R.J., Fortino, M.D., 1997. Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cement. J. Biomech. 30 (4), 339-346. 114. Bohner, M., Gasser, B., Baroud, G., Heini, P., 2003. Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structure. Biomaterials 24, 2721-2730. 115. Teo, J.C.M., Si-Hoe, K.M., Keh, J.E.L., Teoh, S.H., 2006. Relationship between CT intensity, micro-architecture and mechanical properties of porcine vertebral cancellous bone. Clin. Biomech. 21, 235-244. 116. Walsh, M.P., Wijdicks, C.A., Parker, J.B., Hapa, O., LaPrade, R.F., 2009. A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction.Am. J. Sports Med. 37 (1), 160-167. 117. Feng, L., Chittenden, M., Schirer, J., Dickinson, M., Jasiuk, I., 2012. Mechanical properties of porcine femoral cortical bone measured by nanoindentation. J. Biomech. 45, 1775-1782. 118. Peric, M., Dumic-Cule, I., Grcevic, D., Matijasic, M., Verbanac, D., Paul, R., Grgurevic, L., Trkulja, V., Bagi, C.M., Vukicevic, S., 2015. The rational use of animal models on the evaluation of novel bone regenerative therapies. Bone 70, 73-86. 119. Proffen, B.L., McElfresh, M., Fleming, B.C., Murray, M.M., 2012. A comparative anatomical study of the human knee and six animal species. The Knee 19, 493-499. 120. Osterhoff, G., Loffler, S., Steinke, H., Feja, C., Josten, C., Hepp, P., 2011. Comparative anatomical measurements of osseous structures in the ovine and human knee. The Knee 18, 98-103. 121. Steinberg, E.L., Blumberg, N., Dekel, S., 2005. The fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study. J. Biomech. 38, 63-68. 122. Kukla, C., Gaebler, C., Pichl, R.W., Prokesch, R., Heinze, G., Heinz, T., 2002. Predictive geometric factors in a standardized model of femoral neck fracture. Experimental study of cadaveric human femurs. Injury, Int. J. Care Injured 33, 427-433. 123. Maier, A., Regazzoni, P., 2000. Prevention of malunions in the rotation of complex fractures of the distal femur treated using the Dynamic Condylar Screw (DCS): An anatomical graphic analysis using computed tomography on cadaveric specimens. Injury, Int. J. Care Injured 31, S-B63-S-B69. 124. Kukla, C., Pichl, W., Prokesch, R., Jacyniak, W., Heinze, G., Gatterer, R., Heinz, T., 2001. Femoral neck fracture after removal of the standard gamma interlocking nail: a cadaveric study to determine factors influencing the biomechanical properties of the proximal femur. J. Biomech. 34, 1519-1526. 125. McNamara, B.P., Cristofolini, L., Toni, A., Taylor, D., 1994. Evaluation of experimental and finite element models of synthetic and cadaveric femora for pre-clinical design-analysis. Clin. Mat. 17, 131-140. 126. Pierre, M.A., Zurakowski, D., Nazarian, A., Hauser-Kara, D.A., Snyder, B.D., 2010. Assessment of the bilateral asymmetry of human femurs based on physical, densitometric, and structural rigidity characteristics. J. Biomech. 43, 2228-2236. 127. Sedlacek, R.C., O'Connor, D.O., Lozynsky, A.J., Harris, W.H., 1997. Assessment of the symmetry of bone strains in the proximal femoral medial cortex under load in bilateral pairs of cadaver femurs. J. Arthrop. 12 (6), 689-694. 128. Eberle, S., Gerber, C., von Oldenburg, G., Högel, F., Augat, P., 2010. A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro testing. Proc. IMechE Vol. 224 Part H: J. Engineering in Medicine, 1141-1152. 129. Simoes, J.A., Vaz, M.A., Blatcher, S., Taylor, M., 2000. Influence of head constraint and muscle forces on the strain distribution within the intact femur. Med. Eng. Phys. 22, 453-59. 130. Choi, J.K., Gardner, T.R., Yoon, E., Morrison, T.A., Macaulay, W.B., Geller, J.A., 2010. The effect of fixation technique on the stiffness of comminuted Vancouver B1 periprosthetic femur fractures. J. Arth. 25, 124-128. 131. Talbot, M., Zdero, R., Schemitsch, E.H., 2008. Cyclic loading of periprosthetic fracture fixation constructs. J. Trauma 64, 1308-1312. 132. Zdero, R., Bougherara, H., Dubov, A., Shah, S., Zalzal, P., Mahfud, A., Schemitsch, E.H., 2009. The effect of cortex thickness on intact femur biomechanics: a comparison of finite element analysis with synthetic femurs. Proc. IMechE Vol. 224 Part H: J. Engineering in Medicine, 831-40. 133. Shah, S., Kim, S.Y.R., Dubov, A., Schemitsch, E.H., Bougherara, H., Zdero, R., 2011. The biomechanics of plate fixation of periprosthetic femoral fractures neat the tip of a total hip implant: cables, screws, or both? Proc. IMechE Vol 225 Part H: J. Engineering in Medicine, 845-856. 134. Otani, T., Whiteside, L.A., White, S.E., 1993a. Strain distribution in the proximal femur with flexible composite and metallic femoral components under axial and torsional loads. J. Biomed. Mater. Res. 27, 575-585. 135. Heiner, A.D., 2008. Structural properties of fourth-generation composite femurs and tibias. J. Biomech. 41, 3282-84. 136. Panjabi, M.M., Trumble, T., Hult, J.E., Southwick, W.O., 1985. Effect of femoral stem length on stress raisers associated with revision hip arthroplasty. J. Orthop. Res. 3, 447-455. 137. Ebrahimi, H., Rabinovich, M., Vuleta, V., Zalcman, D., Shah, S., Dubov, A., Roy, K., Siddiqui, F.S., Schemitsch, E.H., Bougherara, H., Zdero, R., 2012. Biomechanical properties of an intact, injured, repaired, and healed femur: An experimental and computational study. Journal of the Mechanical Behavior of Biomedical Materials 16, 121–135. 138. Zdero, R., Shah, S., Mosli, M., Schemitsch, E.H., 2009. The effect of load application rate on the biomechanics of synthetic femurs. Proc. IMechE Vol 224 Part H: J. Engineering in Medicine, 599-605. 139. Stolk, J., Verdonschot, N., Cristofolini, L., Toni, A., Huiskes, R., 2002. Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests. J. Biomech. 35, 499-510. 140. Cordey, J., Borgeaud, M., Frankle, M., Harder, Y., Martinet, O., 1999. Loading model for the human femur taking the tension band effect of the ilio-tibial tract into account. Injury, Int. J. Care Injured 30, S-A26-S-A30. 141. Barker, R., Takahashi, T., Toms, A., Gregson, P., Kuiper, J.H., 2006. Reconstruction of femoral defects in revision hip surgery: risk of fracture and stem migration after impaction bone grafting. J. Bone Joint Surg. Br. 88, 832-836. 142. Wilson, D., Frei, H., Masri, B.A., Oxland, T.R., Duncan, C.P., 2005. A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fractures. Clin. Biomech. 20, 70-76. 143. Chong, A.C.M., Friis, E.A., Ballard, G.P., Czuwala, P.J., Cooke, F.W., 2007. Fatigue performance of composite analogue femur constructs under high activity loading. Annals of Biomedical Engineering 35 (7), 1196-1205. 144. Cristofolini, L., Erani, P., Savigni, P., Grupp, T., Thies, O., Viceconti, M., 2007. Increased long-term failure risk associated with excessively thin cement mantle in cemented hip arthroplasty: A comparative in vitro study. Clin. Biomech. 22, 410-421. 145. Ramos, A., Simões, J.A., 2009. The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses. 146. Sangiorgio, S.N., Longjohn, D.B., Dorr, L.D., Ebramzadeh, E., 2011. The influence of proximal stem geometry and surface finish on the fixation of a double-tapered cemented femoral stem. J. Biomech. 44, 22-27. 147. Ghosh, R., Gupta, S., 2014. Bone remodelling around cementless composite acetabular components: The effects of implant geometry and implant-bone interfacial conditions. J. Mech. Behav. Biomed. Mat. 32, 257-269. 148. Lin, B.A., Thomas, P., Spiezia, F., Loppini, M., Maffulli, N., 2013. Changes in daily physical activity before and after total hip arthroplasty. A pilot study using accelerometry. The Surgeon 11, 87-91. 149. Agnostini, V., Ganio, D., Facchin, K., Cane, L., Carneiro, M., Knaflitz, M., 2014. Gait parameters and muscle activation patterns at 3, 6, and 12 months after total hip arthroplasty. J. Arthrop. 29, 1265-1272. 150. Horstmann, T., Listringhaus, R., Haase, G-B., 2013. Changes in gait patterns and muscle activity following total hip arthroplasty: A six-month follow-up. Clin. Biomech. 28, 762-769. 151. Nishida, I., Maeda, M., Gordon, D., Robertson, E., Shirase, K., 2011. Development of an ergonomic musculoskeletal model to estimate muscle forces during vertical jumping. Procedia Eng. 13, 338-343. 152. Sverdlova, N.S., Witzel, U., 2010. Principles of determination and verification of muscle forces in the human musculoskeletal system: Muscle forces to minimise bending stress. J. Biomech. 43, 387-396. 153. Lloyd, D.G., Besier, T.F., 2003. An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo. J. Biomech. 36, 765-776. 154. Gagnon, D., Arjmand, N., Plamondon, A., Shirazi-Adl, A., Lariviere, C., 2011. An improved multi-joint EMG-assisted optimization approach to estimate joint and muscle forces in a musculoskeletal model of the lumbar spine. J. Biomech. 44, 1521-1529. 155. Augat, P., Penzkofer, R., Nolte, A., Maier, M., Panzer, S., Oldenburg, G., Pueschl, K., Simon, U., Buhren, V., 2008. Interfragmentary movement in diaphyseal tibia fractures fixed with locked intramedullary nails. J. Orhtop. Trauma 22, 30-36. 156. Milgrom, C., Finestone, A., Hamel, A., Mandes, V., Burr, D., Sharkey, N., 2003. A comparison of bone strain measurements at anatomically relevant sites using surface gauges versus strain gauged bone staples. J. Biomech. 37, 947-952. 157. Verhulp, E., van Rietbergen, B., Huiskes, R., 2003. A three-dimensional digital image correlation technique for strain measurements in microstructures. J. Biomech. 37, 1313-1320. 158. Yang, P.F., Sanno, M., Bruggemann, G.P., Rittweger, J., 2012. Evaluation of the performance of a motion capture system for small displacement recording and a discussion for its application potential in bone deformation in vivo measurements. Proc. IMechE Vol 226(11) Part H: J. Engineering in Medicine, 838-847. 159. Troy, K.L., Brown, T.D., Conzemius, M.G., 2009. Contact stress distributions on the femoral head of the emu. J. Biomech. 42, 2495–2500. 160. Senalp, A.Z., Kayabasi, O., Kurtaran, H., 2007. Static, dynamic and fatigue behavior of newly designed stem shapes for hip prosthesis using finite element analysis. Mat. Des. 28, 1577-1583. 161. Kayabasi, O., Ekici, B., 2007. The effects of static, dynamic and fatigue behavior on three-dimensional shape optimization of hip prosthesis by finite element method. Mat. Des. 28, 2269-2277. 162. Jeffers, J.R.T., Browne, M., Lennon, A.B., Prendergast, P.J., 163. Mihalko, W.M., Beaudoin, A.J., Cardea, J.A., Krause, W.R., 1992. Finite-element modelling of femoral shaft fracture fixation techniques post total hip arthroplasty. J. Boimech. 25, 469. 164. Mann, K.A., Bartel, D.L., Wright, T.M., Burstein, A.H., 1995. Coulomb frictional interfaces in modeling cemented total hip replacements: a more realistic model. J. Biomechanics 28, 1067-1078. 165. Spiers, A.D., Heller, M.O., Taylor, W.R., Duda, G.N., Perka, C., 2007. Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implant. Clin. Biomech. 22, 431-439. 166. Cheung, G., Zalzal, P., Bhandari, M., Spelt, J.K., Papini, M., 2004. Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading. Medical Engineering & Physics 26, 93-108. 167. Gefen, A., 2002. Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws. Med. Biol. Eng. Comput. 40, 311-322. 168. Norman, T.L., Thyagarajan, G., Saligrama, V.C., Gruen, T.A., Blaha, J.D., 2001. Stem surface roughness alters creep induced subsidence and 'taper-lock' in a cemented femoral hip prosthesis. J. Biomech. 34, 1325-1333. 169. Chen, D.W., Lin, C.L, Hu, C.C., Wu, J.W., Lee, M.S., 2012. Finite element analysis of different repair methods of Vancouver B1 periprosthetic fractures after total hip arthroplasty. Injury, 1-5. 170. Nuno, N., Groppetti, R., Senin, N., 2006. Static coefficient of friction between stainless steel and PMMA used in cemented hip and knee implants. Clin. Biomech. 21, 956-962. 171. Köbel, R., Bergmann, G., Boenick, U., 1976. Mechanical engineering of the cement-bone bond. In: Engineering in Medicine 347-357. Springer-Verlag, New York. 172. Bean, D.J., Convery, F.R., Woo, S.L.Y., Lieber, R.L., 1987. Regional variation in shear strength of the bone-polymethylmethacrylate interface. J. Arthrop. 2 (4), 293-298. 173. Ryf CR, Arraf J. Postoperative fracture treatment: general considerations. In: Ruedi TP, Buckley RE, Moran CG, editors. AO principal of fracture management. 2nd ed. Davos: AO Publishing; 2007. p. 447. 174. National Instruments, 2014. Measuring Strain with Strain Gages. Available at www.ni.com/white-paper/3642/en [Accessed March 2015] 175. Chong, A.C.M., Miller, F., Buxton, M., Friis, E.A., 2007. Fracture toughness and fatigue crack propagation rate of short fiber reinforced epoxy composites for analogue cortical bone. Journal of Biomechanical Engineering 129, 487-493. 176. Anderson, A.E., Ellis, B.J., Weiss, J.A., 2007. Verification, validation and sensitivity studies in computational biomechanics. Computer Methods in Biomechanics and Biomedical Engineering 10 (3), 171-184. 177. Oberkampf, W.L., Trucano, T.G., Hirsch, C., 2002. Verification, validation, and predictive capability on computational engineering and physics. Foundations for Verification and Validation in the 21st Century Workshop, Johns Hopkins University, 2002. 178. Viceconti, M., Olsen, S., Burton, K., 2005. Extracting clinically relevant data from finite element simulations. Clinical Biomechanics 20, 451-454. 179. Blottner, F.G., 1990. Accurate Navier-Stokes results for the hypersonic flow over a spherical nosetip. J. Spacecraft 27 (2). 180. Boehm, B.W., 1981. Software engineering economics. Prentice Hall, Englewood Cliffs, New Jersey. 181. Jones, A.C., Wilcox, R.K., 2008. Finite element analysis of the spine: Towards a framework of verification, validation and sensitivity analysis. Medical Engineering and Physics 30, 1287-1304. 182. Sargent, R.G., 2011. Verification and validation of simulation models. Proceeding of the 2011 Winter Simulation Conference, 183-198. 183. Henninger, H.B., Reese, S.P., Anderson, A.E., Weiss, J.A., 2010. Validation of computational models in biomechanics. Proc. Inst. Mech. Eng. H 224 (7), 801-812. 184. Desmarais-Trépanier C. femur_sawbone.zip, From the Biomechanics European Laboratory _BEL_, Finite Element Mesh Repository, http://www.tecno.ior.it/VRLAB. 2009. 185. Benham, P.P., Crawford, R.J., Armstrong, C.G., 1996. Mechanics of Engineering Materials. Prentice Hall, Singapore. 186. Kusy, R.P., 1978. Characterization of self-curing acrylic bone cements. Journal of Biomedical Materials Research 12, 271-305. 187. De Wijn, J.R., Slooff, T.J.J.H., Driessens, F.C.M., 1975. Characterization of bone cements. Acta Orthop. Scand. 46. 38-51. 188. Holm, N.J., 1977. The modulus of elasticity and flexural strength of some acrylic bone cements. Acta Orthop. Scand. 48, 436-442. 189. Davies, J.P., O'Conner, D.O., Greer, J.A., Harris, W.H., 1987. Comparison of the mechanical properties of Simplex P, Zimmer Regular, and LVC bone cements. Journal of Biomedical Materials Research 21, 719-730. 190. Dunne, N.J., Orr, J.F., 2001. Influence of mixing techniques on the physical properties of acrylic bone cement. Biomaterials 22, 1819-1826. 191. Dunne, N.J., Orr, J.F., Mushipe, M.T., Eveleigh, R.J., 2003. The relationship between porosity and fatigue characteristics of bone cements. Biomaterials 24, 239-245. 192. Wilkinson, J.M., Eveleigh, R., Hamer, A.J., Milne, A., Miles, A.W., Stockley, I., 2000. Effect of mixing technique on the properties of acrylic bone-cement. The Journal of Arthroplasty 15 (5), 663-667. 193. Gilroy, D., Younge, A.M., Phillips, A.T.M., Wheel, M., Riches, P.E., 2014. Characterisation and Validation of Sawbones Artificial Composite Femur Material. 7th World Congress of Biomechanics. 194. Abaqus, 2012. ABAQUS 6.12 Documentation. Dassault Systèmes, Providence, RI, USA. 195. Zdero, R., Olsen, M., Bougherara, H., Schemitsch, E.H., 2008. Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis. Proc. IMechE Vol. 222 Part H: J. Engineering in Medicine, 1175-1183. 196. Wieding, J., Souffrant, R., Fritsche, A., Mittelmeier, W., Bader, R., 2012. Finite element analysis of osteosynthesis screw fixation in the bone stock: an appropriate method for automatic screw modelling. PLoS ONE 7(3), 1-10. 197. Liu, G.R., Quek, S.S., 2013. The finite element method: a practical course. Elsevier, Oxford. 198. Litchman, H.M., Richman, M.H., Warman, M., Mitchell, J., 1978. Improvement of the mechanical properties of polymethylmethacrylate by graphite fiber reinforcement. Trans. Orthop. Res. Soc., 2, 86. 199. Saha, S., Warman, M.L., 1979. Compressive and shear properties of graphite fiber reinforced bone cement. Orthop. Trans., 3, 169. 200. Saha, S., Warman, M.L., 1979. Improved mechanical properties of graphite fiber reinforced polymethylmethacrylate. Trans. 17th Int. Biomater. Symp. and 5th Ann. Meeting SOC. Biomater., 3, 174. 201. Heller, M.O., Bergmann, G., Deuretzbacher, G., Dürselen, L., Pohl, M., Claes, L., Haas, N.P., Duda, G.N., 2001. Musculo-skeletal loading conditions at the hip during walking and stair climbing. J. Biomech. 34, 883-893. 202. Retpen, J.B., Jensen, J.S., 1993. Risk factors for recurrent aseptic loosening of the femoral component after cemented revision. J. Arthroplasty 8 (5), 471-478. 203. Blain, H., Chavassieux, P., Portero-Muzy, N., Bonnel, F., Canovas, F., Chammas, M., Maury, P., Delmas, P.D., 2008. Cortical and trabecular bone distribution in the femoral neck in osteoporosis and osteoarthritis. Bone 43, 862-868. 204. Karrholm, J., Borssen, B., Lowenhielm, G., Snorrason, F., 1994. Does early micromotion of femoral stem prostheses matter? J. Bone Joint Surg. (Br) 76-B, 912-7. 205. Alfaro-Adrian, J., Gill, H.S., Murray, D.W., 2001. Should total hip arthroplasty femoral components be designed to subside? J. Arthrop. 16 (5), 598-606."],"dcterms:accessrights":["public"],"dc:title":["Optimisation Of Fixation Methods For Vancouver Type B2 And B3 Periprosthetic Femoral Fracture Treatment"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T21:30:57Z"}