{"id":{"repo_id":"whiterose","oai_identifier":"oai:etheses.whiterose.ac.uk:9591"},"canonical_url":"https://search.ndltd.org/etd/whiterose/oai:etheses.whiterose.ac.uk:9591","repository":{"repo_id":"whiterose","name":"White Rose University Consortium","base_url":"https://etheses.whiterose.ac.uk/cgi/oai2"},"display":{"title":"Computational Fluid Dynamic Modeling of In-duct UV Air Sterilisation Systems.","abstract":"In-duct UVC air sterilisation is a technology that can help in the reduction and control of airborne diseases. Nevertheless, improvements in sterilisation performance efficiency are required for the technology to succeed in an increasingly restricted energy society. Computational fluid Dynamics (CFD) was used to systematically improve the performance of in-duct UVC air sterilisation systems. The Discrete Ordinates method (DO) was used to model lamp irradiation, and a user defined function (UDF) to model the injection of microorganisms inside the duct to then calculate the average UV dose of the system, with this it was possible to reproduce test results published by EPA. After the CFD model was validated, operation parameters such as wall reflectivity, lamp location, lamp position, air velocity and airflow patterns were analysed. It was found that accurate information of UVC susceptibility for microorganisms in air was essential for the correct modeling of UVC air sterilisation systems using CFD, and current available data contain considerable variations that needed to be analysed and interpreted in an appropriate manner. It was also found that the DO method was appropriate to model lamp irradiation and could account for reflectivity, and that CFD was robust enough to reproduce lab tests results. Moreover it was found that airflow patterns, and lamp location and position influenced the sterilisation performance of a UVC system. Results include a comprehensive list of microorganisms UVC susceptibilities in air (Chapter 3); a set of CFD models that can be used for validation or calibration for future studies and a confirmation that CFD is capable to model in-duct UVC air sterilisation systems (Chapter 5). Ultimately this research presents a series of conclusions that will help on the design of more efficient in-duct UVC air sterilisation systems.","abstract_html":"In-duct UVC air sterilisation is a technology that can help in the reduction and control of airborne diseases. Nevertheless, improvements in sterilisation performance efficiency are required for the technology to succeed in an increasingly restricted energy society. Computational fluid Dynamics (CFD) was used to systematically improve the performance of in-duct UVC air sterilisation systems. The Discrete Ordinates method (DO) was used to model lamp irradiation, and a user defined function (UDF) to model the injection of microorganisms inside the duct to then calculate the average UV dose of the system, with this it was possible to reproduce test results published by EPA. After the CFD model was validated, operation parameters such as wall reflectivity, lamp location, lamp position, air velocity and airflow patterns were analysed. It was found that accurate information of UVC susceptibility for microorganisms in air was essential for the correct modeling of UVC air sterilisation systems using CFD, and current available data contain considerable variations that needed to be analysed and interpreted in an appropriate manner. It was also found that the DO method was appropriate to model lamp irradiation and could account for reflectivity, and that CFD was robust enough to reproduce lab tests results. Moreover it was found that airflow patterns, and lamp location and position influenced the sterilisation performance of a UVC system. Results include a comprehensive list of microorganisms UVC susceptibilities in air (Chapter 3); a set of CFD models that can be used for validation or calibration for future studies and a confirmation that CFD is capable to model in-duct UVC air sterilisation systems (Chapter 5). Ultimately this research presents a series of conclusions that will help on the design of more efficient in-duct UVC air sterilisation systems.","abstract_has_math":false,"creators":["Cortes Capetillo, Azael Jesus"],"institution":"University of Leeds","degree_name":"Ph.D","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Noakes, Catherine","Sleigh, Andrew"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-01","date_published":"2015-01","updated_at":"2026-11-18T21:31:10Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.660101"],"render_values":[{"text":"uk.bl.ethos.660101","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.whiterose.ac.uk/id/eprint/9591/1/Thesis%20Master%20Document-3-corrections.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.whiterose.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.whiterose.ac.uk%3A9591","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Noakes, Catherine","Sleigh, Andrew"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["Conacyt"]},{"key":"dc:creator","label":"Author","values":["Cortes Capetillo, Azael Jesus"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-01-09"]},{"key":"dc:date.issued","label":"Date","values":["2015-01"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Leeds"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Civil Engineering (Leeds)"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Leeds"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.whiterose.ac.uk/id/eprint/9591/"]},{"key":"dc:relation.references","label":"Dc Relation References","values":["ABDALLAH, A. M., RASHID, M., ADROUB, S. A., ARNOUX, M., ALI, S. & SOOLINGEN, D. V. 2012. Complete Genome Sequence of Mycobacterium phlei Type Strain RIVM601174. Journal of Bacteriology, 194, 12. ALFANO, O. M. & CASSANO, A. E. 2008. Photoreactor Modeling: Applications to Advanced Oxidation Processes. International Journal of Chemical Reactor Engineering, 6, 20. ANSYS, I. 2009. 5.3.6 Discrete Ordinates (DO) Radiation Model Theory [Online]. Available: https://www.sharcnet.ca/Software/Fluent12/html/th/node115.htm. ANSYS, I. 2011. ANSYS FLUENT Theory Guide, ANSYS, Inc. ASHRAE 2003. ASHRAE HVAC Applications handbook, Atlanta, GA. ASHRAE 2007. Chapter 7 Health Care Facilities, ASHRAE. ASHRAE 2008a. 3.3.6 ASHRAE Handbook Chapter 16: Ultraviolet lamp systems. American Society of Heating, Refrigeration and Air Conditioning. ASHRAE 2008b. Air Cleaners for Particulate Contaminants. ASHRAE Handbook - HVAC System and Equipment. ASHRAE 2009a. Chapter 11 Air Contaminants. ASHRAE Applications Handbook, 22. ASHRAE 2009b. Chapter 29 Industrial Gas Cleaning And Air Pollution Control. ASHRAE Applications Handbook, 30. ASHRAE 2011. Chapter 60 Ultraviolet Air and Surface Treatment. BARKER, J., STEVENS, D. & BLOOMFIELD, S. F. 2001. Spread and prevention of some common viral infections in community facilities and domestic homes. Journal of Applied Microbiology, 91, 7-21. BARTL, J. & BARANEK, M. 2004. Emissivity of aluminium and its importance for radiometric measurement. Measurement of Physical Quantities, 43, 3136. BEEBE, J. M. 1959. Stability of disseminated aerosols of Pasteurella tularensis subjected to simulated solar radiations at various humidities. J Bacteriol, 78, 7. BEEBE, J. M. & PIRSCH, G. W. 1958. Response of air-borne species of Pasteurella to artificial radiation simulating sunlight under different conditions of relative humidity. Appl Microbiol, 6, 12. BEGGS, C. B. 2003. The Airborne Transmission of Infection in Hospital Buildings: Fact or Fiction? Indoor and Built Environment, 12, 9. BEGGS, C. B., FLETCHER, L. A., SLEIGH, P. A., KERR, K. G. & NOAKES, C. An experimental method for determining the UV susceptibility of airborne microorganisms using an upper room UV field. Proceedings of the 2nd International Congress on Ultraviolet Technologies, 9-11 th July 2003 Vienna. BEGGS, C. B., KERR, K. G., DONNELLY, J. K., SLEIGH, P. A., MARA, D. D. & CAIRNS, G. 2000. An engineering approach to the control of Mycobacterium tuberculosis and other airborne pathogens: a UK hospital based pilot study. Transactions of the Royal Society of Tropical Medicine and Hygiene, 94, 5. BEGGS, C. B., NOAKES, C. J., SLEIGH, P. A., FLETCHER, L. A. & KERR, K. G. 2005. Methodology for determining the susceptibility of airborne microorganism to irradiation by an upper-room UVGI system. Journal of Aerosol Science, 18. BERNSTEIN, R. S., SORENSON, W. G., GARABRANT, D., REAUX, C. & TREITMAN, R. D. 1983. Exposures to Respirable, Airborne Penicillium from a Contaminated Ventilation System: Clinical, Environmental and Epidemiological Aspects. American Industrial Hygiene Association, 44, 9. BLATCHLEY 1997. Numerical Modelling of UV Intensity: Application to Collimated-Beam Reactors and Continuous-Flow Systems. Wat. Res., 31, 14. BLATT, M. H. 2006. Avanced HVAC Systems for Improving Indoor Environmental Quality and Energy Performance of California K-12 Schools; Applications Guide for Off-the-Shelf Equipment for UVC Use. California Energy Commission. BOLTON, J. R. 2000. Calculation of Ultraviolet Fluence Rate Distribution in an Annular Reactor: Significance of Refraction and Reflection. Wat. Res., 34, 10. BOLTON, J. R. 2001. Ultraviolet Applications Handbook. BOLTON, J. R. & COTTON, C. A. 2001. The ultraviolet Disinfection Handbook, American Waterworks Association. BOLTON PHOTOSCIENCE INC. 2011. UVCalc Software [Online]. Available: https://secure40.securewebsession.com/boltonuv.com/store/soft.php 2011]. BOSHOF, H. I. M., REED, M. B., ILL, C. E. B. & MIZRAHI, V. 2003. DnaE2 Polymerase Contributes to In Vivo Survival and the Emergence of Drug Resistance in Mycobacterium tuberculosis. Cell, 113, 11. BRINKLE, J. T., SELVIN, S., HODGSON, A. T., FISK, W. J., MENDELL, M. J., KOSHLAND, C. P. & DAISEY, J. M. 1998. Development of New Volatile Organic Compound (VOC) Exposure Metrics and their Relationship to \"Sick Building Syndrome\" Symptoms. Indoor air, 8, 13. BROWN, J. W., MANTE, S. & PASSON, T. J. 1996. Sick-building syndrome and building-related illness.(New and Emerging Pathogens, part 6). Medical Laboratory Observer, 11. BSI EN 1822-1:2009 2009. High efficiency air filters (EPA, HEPA and ULPA). Part 1: Classification, performance testing, marking. CAMFIL FARR 2002. ASHRAE Testing for HVAC Air Filtration A Review of Standards 52.1-1992 & 52.2-1999. Technical Services Bulletin. Camfil Farr. CAMFIL FARR. 2011. Energy & Air quality rating [Online]. Available: http://www.camfilfarr.com/Filter-technology/Energy-Savings/Energy--Air-quality-rating/ [Accessed August 2011]. CASARETT, A. 1968. Radiation Biology, Englewood, Prentice-Hall. CASSANO, A. E., MARTIN, C. A., BRANDI, R. J. & ALFANO, O. M. 1995. Photoreactor Analysis and Design: Fundamentals and Applications. Ind. Eng. Chem. Res, 34, 47. CAUL, E. O. 1994. Small round structured viruses: airborne transmission and hospital control. The Lancet, 343, 1240-1242. CDC, C. F. D. C. A. P. 2011. General Information. Escherichia coli (E. coli) [Online]. Available: http://www.cdc.gov/ecoli/general/index.html [Accessed 09 December 2013]. COLLINS, F. M. 1971. Relative Susceptibility of Acid-Fast and Non-Acid-Fast Bacteria to Ultraviolet Light. Applied and Environmental Microbiology, 21, 3. COOLEY, J., WONG, W., JUMPER, C. & STRAUS, D. 1998. Correlation between the prevalence of certain fungi and sick building syndrome. Occupational and Environmental Medicine, 55, 6. CURTISA, L., CALIA, S., CONROYA, L., BAKERA, K., OUA, C.-H., HERSHOWB, R., NORLOCK-CRUZA, F. & SCHEFF, P. 2005. Aspergillus surveillance project at a large tertiary-care hospital. Journal of Hospital Infection, 59, 9. CHANG, D. & YOUNG, C. 2007. Effect of turbulence on Ultraviolet Germicial Irradiation. Journal of Architectural Engineering, 13, 10. CHANG, J., OSSOFF, S., LOBE, D., DORFMAN, M., DUMAIS, C., QUALLS, R. & JOHNSON, J. 1985. UV innactivation of pathogenic and indicator microorganisms. Applied and Environmental Microbiology, 49, 6. CHICK, E. W., HUDNELL, A. B. & SHARP, D. G. 1963. Ultraviolet sensitivity of fungi associated with mycotic keratitis and other mycoses. Sabouviad, 2, 6. DALY, B. B. 1992. Woods Practical Guide to Fan Engineering. DAVID, H. L., JONES, W. D. & NEWMAN, C. M. 1971. Ultraviolet Light Inactivation and Photoreactivation in the Mycobacteria. Infection and Immunity, 4, 2. DEPARTMENT OF HEALTH, D. 2008. Clean, safe care: Reducing infections and saving lives. NHS. DURAN, J. E. 2010. Development of a CFD-Based model for the simulation of immobilized photocatalytic reactors for water treatment. PhD, The University of British Columbia. ENGLAND, P. H. 2014. Pseudomonas aeruginosa [Online]. Available: http://www.hpa.org.uk/Topics/InfectiousDiseases/InfectionsAZ/PseudomonasAeruginosa/ [Accessed 08 March 2014]. EPA 1997. An Office Building Occupant's Guide to Indoor Air Quality. EPA. EPA 2006a. EPA 600/R-06/050. Technology Evaluation Report. Biological Innactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems. Dust Free Bio-Fighter 4Xtreme, model 21. EPA 2006b. EPA 600/R-06/051 Biological Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems Atlantic Ultraviolet Corporation Aerologic Model AD24-4. EPA. EPA 2006c. EPA 600/R-06/055 Biological Innactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems. Lumalier ADPL-60-8. EPA. ESCOMBE, A. R., MOORE, D. A. J., GILMAN, R. H., NAVINCOPA, M., TICONA, E., MITCHELL, B., NOAKES, C., MARTINEZ, C., SHEEN, P., RAMIREZ, R., QUINO, W., GONZALEZ, A., FRIEDLAND, J. S. & EVANS, C. A. 2009. Upper-Room Ultraviolet Light and Negative Air Ionization to Prevent Tuberculosis Transmission. PLoS MEDICINE, 6, 12. FINNEGAN, M. J., PICKERING, C. A. C. & BURGE, P. S. 1984. The sick building syndrome: prevalence studies. British Medical Journal, 289, 3. FISK, W. J., FAULKNER, D., PALONEN, J. & SEPPANEN, O. 2002. Performance and Cost of Particle Air Filtration Technologies. Indoor air, 12, 12. FLETCHER, L. A. 2004. The influence of relative humidity on the UV susceptibility of airborne gram negative bacteria. IUVA News, 6, 7. FLETCHER, L. A., NOAKES, C. J. & BEGGS, C. B. The importance of Bioaerosols in Hospital Infections and the Potential for Control using Germicidal Ultraviolet Irradiation. Proceedings of the 1st seminar on Applied Aerobiology, 2004. FLETCHER, L. A., NOAKES, C. J., BEGGS, C. B., SLEIGH, P. A. & KERR, K. G. 2003. The Ultraviolet Susceptibility of Aerolised Microorganisms and the Role of Photoreactivation. Second international congress of the IUVA. Vienna. FOARDE, K., FRANKE, D., WEBBER, T., HANLEY, J. & OWEN, K. 2006. Biological Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems: Steril-Aire, Inc. Model SE 1 VO with GTS 24 VO Emitter. Technology Report. EPA. FOARDE, K. K. & HANLEY, J. T. 1999. Determine the efficacy of antimicrobial treatments of fibrous air filters. RTI. FRITZE, D. & PUKALL, R. 2001. Reclassification of Bioindicator Strains Bacillus subtilis DSM 675 and Bacillus subtilis DSM 2277 as Bacillus atrophaeus. International Journal of Systematic and Evolutionary Microbiology, 51, 35-37. GILKESON, C. A. & NOAKES, C. J. 2013. Applications of CFD Simulation to Predicting Upper-room UVGI. Photochemistry and Photobiological. GILLIS, H. L. 1973. Photoreactivation and ultraviolet inactivation of Mycobacteria in air. MSc, Georgia Institute of Technology. GOVAN, HUGHES & VANDAMME 1996. Burkholderia cepacia: medical, taxonomic and ecological issues. J. Med. Microbiol, 45, 13. GRANGE, J. M., YATES, M. D. & KANTOR, I. N. D. 1996. Guidelines for speciation within the Mycobacterium tuberculosis complex. Second edition. World Health Organization. GUSTAVSSON, J. 2000. Air Filters and IAQ. Camfil Farr. GUTIERREZ, R. L., BOURGEOUS, K. N., SALVESON, A., MEIR, J. & SLATER, A. 2006. Microwave UV: A new wave of tertiary disinfection. WEFTEC, 12. HARSTAD, J., DECKER, H. M. & WEDUM, A. G. 1954. Use of ultraviolet irradiation in a room air conditioner for removal of bacteria. Am Ind Hyg Assoc J, 2, 4. HEREAUS NOBLELIGHT 2007. Ultraviolet lamps for disinfection and oxidation. HM GOVERNMENT 2011. Carbon Plan. HO, C. K. 2009a. Evaluation of the reflection and refraction in simulations of UV disinfection using the discrete ordinates radiation model. Water Science and Technology, 59, 8. HO, C. K. 2009b. Radiation Dose Modeling in Fluent. WEF Disinfection 2009 Workshop: Modeling UV Disinfection using CFD. University of North Carolina (UNC): Sandia National Laboratories. HO, Y. S., ADROUB, S. A. & ALEISA, F. 2012. Complete Genome Sequence of Mycobacterium fortuitum subsp. fortuitum Type Strain DSM46621. Journal of Bacteriology, 194, 2. HODGSON, A. T., DESTAILLATS, H., HOTCHI, T. & FISK, W. J. 2008. Benefits and technological challenges in the implementation of TiO2-based ultraviolet photocatalytic oxidation (UVPCO) air cleaners. Indoor air 2008. Copenhagen, Denmark. HODGSON, A. T., SULLIVAN, D. P. & FISK, W. J. 2005. Parametric Evaluation of an Innovative Ultra-violet photocatalytic oxidation (UVPCO) air cleaning technology for indoor applications. Lawrence Berkeley National Laboratory. IEA 2010. Energy Performance Certification of Buildings: A policy tool to improve energy efficiency. Paris: International Energy Agency. IMOBERDORF, G. E., TAGHIPOUR, F. & MOHSENI, M. 2008. Radiation field modeling of multi-lamp, homogeneous photoreactors. Journal of Photochemistry and Photobiology A: Chemistry, 198, 10. IRAZOQUI, H. A., CERDA, J. & CASSANO, A. E. 1973. Radiation Profiles in an Empty Annular Photoreactor with a Source of Finite Spatial Dimensions. AIChE Journal, 19, 8. IRAZOQUI, H. A., CERDA, J. & CASSANO, A. E. 1976. The Radiation Field for the Point and Line Source Approximations and the Three-dimensional Source Models: Applications to Photoreactions. The Chemical Engineering Journal, 11, 11. IUVA 2005a. General Guideline for UVGI Air and Surface Disinfection Systems. Ontario, Canada: International Ultraviolet Association. IUVA 2005b. Guideline for the Design and Installation of UVGI In-duct Air Disinfection Systems in New Building Construction. International UV Association. IUVA 2005c. Guideline for the Design and Installation of UVGI In-duct Air Disinfection Systems.: IUVA. IUVA 2005d. Guideline for the Design and Installation of UVGI Unitary Recirculation and Air Disinfection Systems. IUVA. IUVA 2005e. Medium Pressure and Low Pressure wave length spectrum. JENSEN, M. M. 1964. Inactivation of airborne viruses by ultraviolet irradiation. Applied Microbiology, 3. KARLSSON, B. & RIBBING, C. G. 1982. Optical constants and spectral selectivity of stainless steel and its oxides. Journal of Applied Physics, 53, 6340-6346. KE, Q. S., CRAIK, S. A., EL-DIN, M. G. & BOLTON, J. R. 2009. Development of a Protocol for the Determination of the Ultraviolet Sensitivity of Microorganisms Suspended in air. Aerosol Science and Technology, 43, 6. KERR, J. H. & BARRET, T. L. 2010. Atypical Mycobacterial diseases. Military Dermatology Text book. KETHLEY, T. 1979. Feasibility Study of Germicidal UV Lamps for Air Disinfection in Simulated Patient Care Rooms. San Francisco, Ca: American Public Health Association. KIMA, K. Y. & KIM, C. N. 2006a. Airborne microbiological characteristics in public buildings of Korea. Building and Environment, 42, 9. KIMA, K. Y. & KIM, C. N. 2006b. General of airborne bacteria and fungi identified in the public buildings regulated in Korea In: KOREA, G. O. A. B. A. F. I. I. T. P. B. R. I. (ed.). KING, M. F., NOAKES, C. J., SLEIGH, P. A. & CAMARGO-VALERO, M. 2013. Bioaerosol Deposition in Single and Two-bed Hospital Rooms: A Numerical and Experimental Study. Building and Environment, 59, 11. KO, G., FIRST, M. W. & BURGE, H. A. 2000. Influence of relative humidity on particle size and UV sensitivity of serratia marcescens and Mycobacterium bovis BCG aerosols. Tubercle and lung disease, 80, 12. KOLLER, L. R. 1939. Bactericidal Effects of Ultraviolet Radiation Produced by Low Pressure Mercury Vapor Lamps. Journal of Applied Physics, 10, 624-630. KOWALSKI, W. 2009a. Ultraviolet Germicidal Irradiation Handbook, Springer. KOWALSKI, W. 2009b. Ultraviolet Germicidal Irradiation Handbook. 1 ed.: Springer. KOWALSKI, W. J. 2003. Immune building systems technology, New York, Mc Graw Hill. KOWALSKI, W. J. 2009c. Exposure limits for UV irradiation. KOWALSKI, W. J. & BAHNFLETH, W. P. 2000a. Effective UVGI System Design Through Improved Modelling. Transactions - American Society of Heating Refrigerating and Air Conditioning Engineers, 106, 10. KOWALSKI, W. J. & BAHNFLETH, W. P. 2000b. UVGI Design Basics for air and surface disinfection. HPAC engineering, 10. KOWALSKI, W. J., BAHNFLETH, W. P., WITHAM, D. L., SEVERIN, B. F. & WHITTAM, T. S. 2001. Mathematical Modelling of Ultraviolet Germicidal Irradiation for Air Disinfection. Quantitative Microbiology, 2, 22. KUMARI, D. N. P., HAJI, T. C., KEER, V., HAWKEY, P. M., DUNCANSON, V. & FLOWER, E. 1998. Ventilation grilles as a potential source of methicillin-resistant Staphylococcus aureus causing an outbreak in an orthopaedic ward at a district general hospital Journal of Hospital Infection, 39, 7. LAI, K., BURGE, H. A. & FIRST, M. 2004. Size and UV germicidal irradiation susceptibility of Serratia marcescens when aerosolized from different suspending media. Applied and Environmental Microbiology, 70, 8. LAU, J. 2009. Lamp and In-Duct Device Modelling For UVGI Systems Performance Prediction. Doctor of Philosophy, The Pennsylvania State University. LEE, B., BAHNFLETH, W. & AUER, K. Life-Cycle Cost Simulation of In-Duct Ultraviolet Germicidal Irradiation Systems. Proceedings of Building Simulation, 2009 Glasgow, Scotland. LEEDS, U. O. 2010. Fantastic and unique swimming pool [Online]. Leeds. Available: http://sport.leeds.ac.uk/page.asp?section=64&sectionTitle=Swimming+Pool [Accessed 09 August 2011]. LI, C.-S. & KUO, Y.-M. 1992. AIRBORNE CHARACTERIZATION OF FUNGI INDOORS AND OUTDOORS. Aerosol Sci, 23, 4. LIGHTSOURCES. 2009. Products Data Sheets [Online]. Available: http://www.germicidal.com/datasheets.php#ho [Accessed 25 November 2009 2009]. LIU, D. 2004. Numerical simulation of UV Disinfection Reactors: Impact of Fluence Rate Distribution and Turbulence Modelling. PhD, North Carolina State university. LIU, D., WU, C., LINDEN, K. & JOEL, D. 2007. Numerical simulation of UV disinfection reactors: Evaluation of alternative turbulence models. Applied Mathematical Modelling, 31, 16. LUCKIESH, M. 1946. Applications of Germicidal, Erythemal and Infrared Energy. LUCKIESH, M., TAYLOR, A. H., T., K. & ET., L. 1949. Inactivation of molds by germicidal ultraviolet energy. J Franklin Inst, 248, 14. MENDELL, M., FISK, W., KREISS, K., LEVIN, H., ALEXANDER, D., CAIN, W., GIRMAN, J., HINES, C., JENSEN, P., MILTON, D., REXROAT, L. & WALLINGFORD, K. 2002. Improving the Health of Workers in Indoor Environments: Priority Research Needs for a National Occupational Research Agenda. Public Health Matters, 92. MENZIES, D. 1997. SPECIFIC ILLNESSES KNOWN OR SUSPECTED TO BE RELATED TO BUILDINGS. MENZIES, D., PASZTOR, J., RAND, T. & BOURBEAU, J. 1999. Germicidal ultraviolet irradiation in air conditioning systems: effect on office worker health and wellbeing: a pilot study. Occupational and Environmental Medicine, 56, 6. MENZIES, D., POPA, J., HANLEY, J. A., RAND, T. & MILTON, D. K. 2003. Effect of ultraviolet germicidal lights installed in office ventilation systems on workers’ health and wellbeing: double-blind multiple crossover trial. THE LANCET, 362, 7. MILLER, S. C. M., LIPUMA, J. J. & PARKE, J. L. 2002. Culture based and Non-Growth Dependent Detection of the Burkholderia cepacia complex in Soil Environments. Applied and Environmental Microbiology, 68, 9. MILLER, S. L., LINNES, J. & LUONGO, J. 2013. Ultraviolet germicidal irradiation: future directions for air disinfection and building applications. Photochemistry and photobiology, 89, 777-781. MUNAKATA, N. & RUPERT, C. 1975. Effects of DNA-polymerase-defective and recombination-deficient mutations on the ultraviolet sensitivity of Bacillus Subtillis spores. Mutat Res, 27, 13. NAKAMURA, H. 1987. Sterilization efficacy of ultraviolet irradiation on microbial aerosols under dynamic airflow by experimental air conditioning systems. Bull Tokyo Med Dent Univ, 34, 16. NAKAMURA, L. K. 1989. Taxonomic Relationship of Black-Pigmented Bacillus subtilis Strains and a Proposal for Bacillus atrophaeus sp. nov. international journal of systematic Bacteriology, 39, 295-300. NATIONAL AUDIT OFFICE 2004. Improving patient care by reducing the risk of hospital acquired infection: A progress report. Ordered by the House of Commons. NEIDLE, S. 1999. Oxford Handbook of Nucleic Acid Structure, New York, Oxford University Press. NHS. 2008. Smart Solutions For HCAI - Frequently Asked Questions [Online]. 2008. Available: http://www.smartsolutionsforhcai.co.uk/faq.htm 2008]. NICHOLSON, W. L. & GALEANO, B. 2003. UV Resistance of Bacillus anthracis spores Revisited: Validation of Bacillus spores as UV Surrogates for Spores of B. anthracis Sterne. Applied and Environmental Microbiology, 69, 4. NOAKES, C. J., BEGGS, C. B. & SLEIGH, P. A. 2004. Modelling the Performance of Upper Room Ultraviolet Germicidal Irradiation Devices in Ventilated Rooms: Comparison of Analytical and CFD Methods. Indoor and Built Environment, 13, 12. NOAKES, C. J., FLETCHER, L. A., BEGGS, C. B., SLEIGH, P. A. & KERR, K. G. 2003. Development of a numerical model to simulate the biological inactivation of airborne microorganisms in the presence of ultraviolet light. Journal of Aerosol Science, 35, 19. NTC, N. T. C. 2007. Tuberculosis Infection Control: A practical manial for preventing TB. San Francisco: The Francis J. Curry National Tuberculosis Center. PAREEK, V. K. 2004. Light Intensity Distribution in a Phototcatalytics Reactor Using Finite Volume. AIChE Journal, 50, 16. PASTUSZKA, J., PAW, U. K. T., LIS, D. O., WLAZLO, A. & UFIG, K. 1999. Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland. Atmospheric Environment, 34, 10. PECCIA, J. & HERNANDEZ, M. 2001. Photoreactivation in Airborne Mycobacterium parafortuitum. Applied and Environmental Microbiology, 67, 8. PECCIA, J. & HERNANDEZ, M. 2004. UV-Induced Inactivation Rates for Airborne Mycobacterium bovis BCG. Journal of Occupational and Environmental Hygiene, 1, 7. PECCIA, J., WORTH, H. M., MILLER, S. & HERNANDEZ, M. 2001. Effects of relative humidity on the ultraviolet induced inactivation of airborne bacteria. Aerosol Science and Technology, 35, 13. PERAL, J., DOMENECH, X. & OLLIS, D. F. 1997. Heterogeneous Photocatalysis for the purification, decontamination and deodorization of air. J. Chem. Technol. Biotechnol, 23. PEREZ, A. R. & MELLO, K. P. A. A.-D. 2000. SpoIIB Localizes to Active Sites of Septal Biogenesis and Spatially Regulates Septal Thinning during Engulfment in Bacillus subtilis. Journal of Bacteriology, 182, 12. PHILIPS 2005. Effects of air temperature and air velocity on a model TUV36W-PLL. PHILIPS 2007. UV Disinfection - Application Information. In: CATALOGUE, P. (ed.). Philips. PRIVATE HEALTHCARE UK. 2005. MRSA : Statistics in UK and Europe [Online]. Private Healthcare UK. Available: http://www.privatehealth.co.uk/hospitaltreatment/treatment-abroad/mrsa-europe/ [Accessed 12 May 2008 2009]. PURCHAS, D. B. & SUTHERLAND, K. 2002. Handbook of filter media, Elsevier Science. REDLICH, C. A., SPARER, J. & CULLEN, M. R. 1997. Sick-building syndrome. The Lancet, 349, 1013-1016. RENTSCHLER, H. & NAGY, R. 1942. Bactericidal action of ultraviolet radiation on air-borne microorganisms. Journal of Bacteriology, 44, 85-94. RILEY, R., WELLS, W., MILLS, C., NYKA, W. & MCLEAN, R. 1957. Air hygiene in tuberculosis: quantitative studies of infectivity and control in a pilot ward. American review of tuberculosis, 75, 420-431. RILEY, R. L. 1961. AIRBORNE PULMONARY TUBERCULOSIS. Bacteriological Reviews, 25, 243-248. RILEY, R. L. 1974. Airborne Infection. The American Journal of Medicine, 57, 10. RILEY, R. L., KNIGHT, M. & MIDDLEBROOK, G. 1976. Ultraviolet susceptibility of BCG and virulent tubercle bacilli. American Review of Respiratory Disease, 113, 6. ROSTRON, J. 1997. Sick building syndrome : concepts, issues, and practice, London, E & FN Spon. RUTALA, W. A., KATZ, E. B., SHERERTZ, R. J. & JR, F. A. S. 1983. Environmental study of a methicillin-resistant Staphylococcus aureus epidemic in a burn unit. . Journal of Clinical Microbiology, 18, 6. RYAN, K., RAY, C. G., AHMAD, N., DREW, W. L. & PLORDE, J. 2010. Sherris Medical Microbiology, McGraw Hill. RYER, A. 1998. Light Measurement Handbook, Newbury, MA, International Light. SAGRIPANTI, J.-L. & LYTLE, C. D. 2010. Sensitivity to ultraviolet radiation of Lassa, vaccinia, and Ebola viruses dried on surfaces. Arch Virol, 156, 6. SCHAAL, K. P. 1991. Medical and microbiological problems arising from airborne infection in hospitals. Journal of Hospital Infection, 18, 9. SGALARI, G., CAMERA-RODA, G. & SANTARELLI, F. 1998. Discrete Ordinate Method in the Analysis of Radiative Transfer in Photocatalytically Reacting Media. Int. Comm. Heat Mass Transfer, 25, 10. SHARP, G. 1940. The effects of ultraviolet light on bacteria suspended in air. Journal of Bacteriology, 38, 535-547. SHAUGHNESSY, R., LEVETIN, E. & ROGERS, C. 1999. The effects of UV-C on biological contamination of AHUs in a commercial office building: Preliminary results. Indoor Environ, 99, 8. SICHEL, C. 2009. Potential fo advance oxidation processes (AOPs) in disinfection and simultaneous emerging contaminants removal: a review. 5th International Congress on UV technologies. Amsterdam: IUVA. SKOV, P., VALBJØRN, O. & PEDERSEN, B. 1990. Influence of indoor climate on the sick building syndrome in an office environment. The Danish Indoor Climate Study Group. Scand J Work Environ Health, 5, 9. SUMER, B. M. 2013. Lecture Notes on Turbulence. DTU Mekanik, Section for Fluid Mechanics, Coastal & Maritime Engineering Building 403, 2800 Lyngby, Denmark, bms@mek.dtu.dk: Technical University of Denmark. SUTHERLAND, K. 2007a. Chapter 7. Other types of separation equipment. Filters and Filtration Handbook. 5th edition ed.: Elsevier Science. SUTHERLAND, K. 2007b. Filters and Filtration Handbook, Elsevier Science. TANG, J. W., LI, Y., EAMES, I., CHAN, P. K. S. & RIDGWAY, G. L. 2006. Factors involved in the aerosol transmission of infections and control ventilation in healthcare premises. Journal of Hospital Infection, 64, 15. TAYLOR, G. J. S., BANNISTER, G. C. & LEEMING, J. P. 1995. Wound Disinfection With Ultraviolet Radiation. Journal of hospital infection, 30, 9. TEEUW, K. B., VANDENBROUCKE-GRAULS, C. M. & VERHOEF, J. 1994. Airborne gram-negative bacteria and endotoxin in sick building syndrome. A study in Dutch governmental office buildings. Archives of Internal Medicine, 154. TOMPKINS, D. T., LAWNICKI, B. J., ZELTNER, W. A. & ANDERSON, M. A. 2005. Evaluation of Photocatalysis for Gas-Phase Air Cleaning - Part 1: Process, Technical, and Sizing Considerations. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc Transactions, III, 24. TROJAN. 2011. Trojan to Supply Australia's Largest Ultraviolet (UV) Disinfection System [Online]. Available: http://www.trojanuv.com/about/news?id=819 [Accessed 09 August 2011]. TRONVILLE, P. 2006. Global Standard for Filter Testing. ASHRAE Journal, 48, 5. TU, J., YEOH, G. H. & LIU, C. 2007. Computational Fluid Dynamics, Butterworth-Heinemann. UK GOVERNMENT 2008. Climate Change Act 2008. In: GOVERNMENT, U. (ed.). UNIVERSAL, E. 2009. Aeguradoras pagan 5.8 mdp por virus H1N1. El Universal.mx. VANOSDELL, D. & FOARDE, K. 2002. Defining the Effectiveness of UV lamps Installed in Circulating Air Ductwork. Arlington, VA: Air-Conditioning and Refrigeration Technology Institute (ARTI). VERSTEEG, H. K. & MALALASEKERA, W. 2007. An Introduction to Computer Fluid Dynamic: The Finite Volume Method, Harlow, Prentice Hall. W.M. HAYNES, E. 2011. CRC Handbook of Chemistry and Physics, Boca Raton, FL, CRC Press/Taylor and Francis. WALKER, C. & KO, G. 2007. Effect of Ultraviolet Germicidal Irradiation on Viral Aerosols. Environ Sci Technol, 41, 16. WANG, B., MORTAZAVI, R. & HAGHIGHAT, F. 2008. Evaluation of Modelling and Measurement Techniques of Ultraviolet Germicidal Irradiation Effectiveness - Towards the Design of Immune Buildings. Indoor and Built Environment, 18, 12. WARGOCKI, P., WYON, D. P., BAIK, Y. K., CLAUSEN, G. & OLEFANGER, P. 1999. Perceived Air Quality, Sick Building Syndrome (SBS) Symptoms and Productivity in an Office with Two Different Pollution Loads. Indoor air, 9, 20. WARGOCKI, P., WYON, D. P., JANUNSDELL, CLAUSEN, G. & OLEFANGER, P. 2000. The Effects of Outdoor Air Supply Rate in an Office on Perceived Air Quality, Sick Building Syndrome (SBS) Symptoms and Productivity. Indoor air, 10. WEBB, S. J. 1970. Differential, Lethal and Mutagenic Action of 254 nm and 320-400nm Radiation on Semi-Dried Bacteria. Photochemistry and Photobiology, 12, 24. WEINSTEIN, R. A., BRIDGES, C. B., KUEHNERT, M. J. & HALL, C. B. 2003. Transmission of influenza: implications for control in health care settings. Clinical Infectious Diseases, 37, 1094-1101. WHO. 2005. Indoor air pollution and health [Online]. Available: http://www.who.int/mediacentre/factsheets/fs292/en/. WHO 2007. Tuberculosis. World Health Organization. WHO 2009a. Epidemic and Pandemic Alert and Response (EPR) - Influenza A(H1N1) - Update 41. World Health Organization. WHO 2009b. Global Tuberculosis Control 2009. World Health Organization. XU, PECCIA, J., FABIAN, P., MARTYNY, J. W., KEVIN, F., HERNANDEZ, M. & MILLER, S. 2003. Efficacy of ultraviolet germicidal irradiation of upper-room air inactivating airborne bacterial spores and mycobacteria in full-scale studies. Atmospheric Environment, 15. YANG, L., LIU, Z., SHI, J., ZHANG, Y., HU, H. & SHANGGUAN, W. 2007. Degradation of indoor gaseous formaldehyde by hybrid VUV and TiO2/UV processes. Separation and Purification Technology, 54, 8. YOUNG, D. F., MUNSON, B. R., OKIISHI, T. H. & HUEBSCH, W. W. 2010. A Brief Introduction to Fluid Mechanics, Hoboken: Wiley. YU, I. T. S., LI, Y., WONG, T. W., TAM, W., CHAN, A. T., LEE, J. H. W., LEUNG, D. Y. C. & HO, T. 2004. Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus. The NEW ENGLAND JOURNAL of MEDICINE, 350, 9."]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.660101"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.whiterose.ac.uk/id/eprint/9591/1/Thesis%20Master%20Document-3-corrections.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In-duct UVC air sterilisation is a technology that can help in the reduction and control of airborne diseases. Nevertheless, improvements in sterilisation performance efficiency are required for the technology to succeed in an increasingly restricted energy society. Computational fluid Dynamics (CFD) was used to systematically improve the performance of in-duct UVC air sterilisation systems. The Discrete Ordinates method (DO) was used to model lamp irradiation, and a user defined function (UDF) to model the injection of microorganisms inside the duct to then calculate the average UV dose of the system, with this it was possible to reproduce test results published by EPA. After the CFD model was validated, operation parameters such as wall reflectivity, lamp location, lamp position, air velocity and airflow patterns were analysed. It was found that accurate information of UVC susceptibility for microorganisms in air was essential for the correct modeling of UVC air sterilisation systems using CFD, and current available data contain considerable variations that needed to be analysed and interpreted in an appropriate manner. It was also found that the DO method was appropriate to model lamp irradiation and could account for reflectivity, and that CFD was robust enough to reproduce lab tests results. Moreover it was found that airflow patterns, and lamp location and position influenced the sterilisation performance of a UVC system. Results include a comprehensive list of microorganisms UVC susceptibilities in air (Chapter 3); a set of CFD models that can be used for validation or calibration for future studies and a confirmation that CFD is capable to model in-duct UVC air sterilisation systems (Chapter 5). Ultimately this research presents a series of conclusions that will help on the design of more efficient in-duct UVC air sterilisation systems."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Computational Fluid Dynamic Modeling of In-duct UV Air Sterilisation Systems."]}]}],"canonical_facts":{"dc:contributor.advisor":["Noakes, Catherine","Sleigh, Andrew"],"dc:contributor.sponsor":["Conacyt"],"dc:creator":["Cortes Capetillo, Azael Jesus"],"dc:date":["2015-01-09"],"dc:date.issued":["2015-01"],"dc:description.abstract":["In-duct UVC air sterilisation is a technology that can help in the reduction and control of airborne diseases. Nevertheless, improvements in sterilisation performance efficiency are required for the technology to succeed in an increasingly restricted energy society. Computational fluid Dynamics (CFD) was used to systematically improve the performance of in-duct UVC air sterilisation systems. The Discrete Ordinates method (DO) was used to model lamp irradiation, and a user defined function (UDF) to model the injection of microorganisms inside the duct to then calculate the average UV dose of the system, with this it was possible to reproduce test results published by EPA. After the CFD model was validated, operation parameters such as wall reflectivity, lamp location, lamp position, air velocity and airflow patterns were analysed. It was found that accurate information of UVC susceptibility for microorganisms in air was essential for the correct modeling of UVC air sterilisation systems using CFD, and current available data contain considerable variations that needed to be analysed and interpreted in an appropriate manner. It was also found that the DO method was appropriate to model lamp irradiation and could account for reflectivity, and that CFD was robust enough to reproduce lab tests results. Moreover it was found that airflow patterns, and lamp location and position influenced the sterilisation performance of a UVC system. Results include a comprehensive list of microorganisms UVC susceptibilities in air (Chapter 3); a set of CFD models that can be used for validation or calibration for future studies and a confirmation that CFD is capable to model in-duct UVC air sterilisation systems (Chapter 5). Ultimately this research presents a series of conclusions that will help on the design of more efficient in-duct UVC air sterilisation systems."],"dc:format":["text"],"dc:identifier":["uk.bl.ethos.660101"],"dc:identifier.uri":["https://etheses.whiterose.ac.uk/id/eprint/9591/1/Thesis%20Master%20Document-3-corrections.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.commercial":["University of Leeds"],"dc:publisher.department":["School of Civil Engineering (Leeds)"],"dc:publisher.institution":["University of Leeds"],"dc:relation.isreferencedby":["https://etheses.whiterose.ac.uk/id/eprint/9591/"],"dc:relation.references":["ABDALLAH, A. M., RASHID, M., ADROUB, S. A., ARNOUX, M., ALI, S. & SOOLINGEN, D. V. 2012. Complete Genome Sequence of Mycobacterium phlei Type Strain RIVM601174. Journal of Bacteriology, 194, 12. ALFANO, O. M. & CASSANO, A. E. 2008. Photoreactor Modeling: Applications to Advanced Oxidation Processes. International Journal of Chemical Reactor Engineering, 6, 20. ANSYS, I. 2009. 5.3.6 Discrete Ordinates (DO) Radiation Model Theory [Online]. Available: https://www.sharcnet.ca/Software/Fluent12/html/th/node115.htm. ANSYS, I. 2011. ANSYS FLUENT Theory Guide, ANSYS, Inc. ASHRAE 2003. ASHRAE HVAC Applications handbook, Atlanta, GA. ASHRAE 2007. Chapter 7 Health Care Facilities, ASHRAE. ASHRAE 2008a. 3.3.6 ASHRAE Handbook Chapter 16: Ultraviolet lamp systems. American Society of Heating, Refrigeration and Air Conditioning. ASHRAE 2008b. Air Cleaners for Particulate Contaminants. ASHRAE Handbook - HVAC System and Equipment. ASHRAE 2009a. Chapter 11 Air Contaminants. ASHRAE Applications Handbook, 22. ASHRAE 2009b. Chapter 29 Industrial Gas Cleaning And Air Pollution Control. ASHRAE Applications Handbook, 30. ASHRAE 2011. Chapter 60 Ultraviolet Air and Surface Treatment. BARKER, J., STEVENS, D. & BLOOMFIELD, S. F. 2001. Spread and prevention of some common viral infections in community facilities and domestic homes. Journal of Applied Microbiology, 91, 7-21. BARTL, J. & BARANEK, M. 2004. Emissivity of aluminium and its importance for radiometric measurement. Measurement of Physical Quantities, 43, 3136. BEEBE, J. M. 1959. Stability of disseminated aerosols of Pasteurella tularensis subjected to simulated solar radiations at various humidities. J Bacteriol, 78, 7. BEEBE, J. M. & PIRSCH, G. W. 1958. Response of air-borne species of Pasteurella to artificial radiation simulating sunlight under different conditions of relative humidity. Appl Microbiol, 6, 12. BEGGS, C. B. 2003. The Airborne Transmission of Infection in Hospital Buildings: Fact or Fiction? Indoor and Built Environment, 12, 9. BEGGS, C. B., FLETCHER, L. A., SLEIGH, P. A., KERR, K. G. & NOAKES, C. An experimental method for determining the UV susceptibility of airborne microorganisms using an upper room UV field. Proceedings of the 2nd International Congress on Ultraviolet Technologies, 9-11 th July 2003 Vienna. BEGGS, C. B., KERR, K. G., DONNELLY, J. K., SLEIGH, P. A., MARA, D. D. & CAIRNS, G. 2000. An engineering approach to the control of Mycobacterium tuberculosis and other airborne pathogens: a UK hospital based pilot study. Transactions of the Royal Society of Tropical Medicine and Hygiene, 94, 5. BEGGS, C. B., NOAKES, C. J., SLEIGH, P. A., FLETCHER, L. A. & KERR, K. G. 2005. Methodology for determining the susceptibility of airborne microorganism to irradiation by an upper-room UVGI system. Journal of Aerosol Science, 18. BERNSTEIN, R. S., SORENSON, W. G., GARABRANT, D., REAUX, C. & TREITMAN, R. D. 1983. Exposures to Respirable, Airborne Penicillium from a Contaminated Ventilation System: Clinical, Environmental and Epidemiological Aspects. American Industrial Hygiene Association, 44, 9. BLATCHLEY 1997. Numerical Modelling of UV Intensity: Application to Collimated-Beam Reactors and Continuous-Flow Systems. Wat. Res., 31, 14. BLATT, M. H. 2006. Avanced HVAC Systems for Improving Indoor Environmental Quality and Energy Performance of California K-12 Schools; Applications Guide for Off-the-Shelf Equipment for UVC Use. California Energy Commission. BOLTON, J. R. 2000. Calculation of Ultraviolet Fluence Rate Distribution in an Annular Reactor: Significance of Refraction and Reflection. Wat. Res., 34, 10. BOLTON, J. R. 2001. Ultraviolet Applications Handbook. BOLTON, J. R. & COTTON, C. A. 2001. The ultraviolet Disinfection Handbook, American Waterworks Association. BOLTON PHOTOSCIENCE INC. 2011. UVCalc Software [Online]. Available: https://secure40.securewebsession.com/boltonuv.com/store/soft.php 2011]. BOSHOF, H. I. M., REED, M. B., ILL, C. E. B. & MIZRAHI, V. 2003. DnaE2 Polymerase Contributes to In Vivo Survival and the Emergence of Drug Resistance in Mycobacterium tuberculosis. Cell, 113, 11. BRINKLE, J. T., SELVIN, S., HODGSON, A. T., FISK, W. J., MENDELL, M. J., KOSHLAND, C. P. & DAISEY, J. M. 1998. Development of New Volatile Organic Compound (VOC) Exposure Metrics and their Relationship to \"Sick Building Syndrome\" Symptoms. Indoor air, 8, 13. BROWN, J. W., MANTE, S. & PASSON, T. J. 1996. Sick-building syndrome and building-related illness.(New and Emerging Pathogens, part 6). Medical Laboratory Observer, 11. BSI EN 1822-1:2009 2009. High efficiency air filters (EPA, HEPA and ULPA). Part 1: Classification, performance testing, marking. CAMFIL FARR 2002. ASHRAE Testing for HVAC Air Filtration A Review of Standards 52.1-1992 & 52.2-1999. Technical Services Bulletin. Camfil Farr. CAMFIL FARR. 2011. Energy & Air quality rating [Online]. Available: http://www.camfilfarr.com/Filter-technology/Energy-Savings/Energy--Air-quality-rating/ [Accessed August 2011]. CASARETT, A. 1968. Radiation Biology, Englewood, Prentice-Hall. CASSANO, A. E., MARTIN, C. A., BRANDI, R. J. & ALFANO, O. M. 1995. Photoreactor Analysis and Design: Fundamentals and Applications. Ind. Eng. Chem. Res, 34, 47. CAUL, E. O. 1994. Small round structured viruses: airborne transmission and hospital control. The Lancet, 343, 1240-1242. CDC, C. F. D. C. A. P. 2011. General Information. Escherichia coli (E. coli) [Online]. Available: http://www.cdc.gov/ecoli/general/index.html [Accessed 09 December 2013]. COLLINS, F. M. 1971. Relative Susceptibility of Acid-Fast and Non-Acid-Fast Bacteria to Ultraviolet Light. Applied and Environmental Microbiology, 21, 3. COOLEY, J., WONG, W., JUMPER, C. & STRAUS, D. 1998. Correlation between the prevalence of certain fungi and sick building syndrome. Occupational and Environmental Medicine, 55, 6. CURTISA, L., CALIA, S., CONROYA, L., BAKERA, K., OUA, C.-H., HERSHOWB, R., NORLOCK-CRUZA, F. & SCHEFF, P. 2005. Aspergillus surveillance project at a large tertiary-care hospital. Journal of Hospital Infection, 59, 9. CHANG, D. & YOUNG, C. 2007. Effect of turbulence on Ultraviolet Germicial Irradiation. Journal of Architectural Engineering, 13, 10. CHANG, J., OSSOFF, S., LOBE, D., DORFMAN, M., DUMAIS, C., QUALLS, R. & JOHNSON, J. 1985. UV innactivation of pathogenic and indicator microorganisms. Applied and Environmental Microbiology, 49, 6. CHICK, E. W., HUDNELL, A. B. & SHARP, D. G. 1963. Ultraviolet sensitivity of fungi associated with mycotic keratitis and other mycoses. Sabouviad, 2, 6. DALY, B. B. 1992. Woods Practical Guide to Fan Engineering. DAVID, H. L., JONES, W. D. & NEWMAN, C. M. 1971. Ultraviolet Light Inactivation and Photoreactivation in the Mycobacteria. Infection and Immunity, 4, 2. DEPARTMENT OF HEALTH, D. 2008. Clean, safe care: Reducing infections and saving lives. NHS. DURAN, J. E. 2010. Development of a CFD-Based model for the simulation of immobilized photocatalytic reactors for water treatment. PhD, The University of British Columbia. ENGLAND, P. H. 2014. Pseudomonas aeruginosa [Online]. Available: http://www.hpa.org.uk/Topics/InfectiousDiseases/InfectionsAZ/PseudomonasAeruginosa/ [Accessed 08 March 2014]. EPA 1997. An Office Building Occupant's Guide to Indoor Air Quality. EPA. EPA 2006a. EPA 600/R-06/050. Technology Evaluation Report. Biological Innactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems. Dust Free Bio-Fighter 4Xtreme, model 21. EPA 2006b. EPA 600/R-06/051 Biological Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems Atlantic Ultraviolet Corporation Aerologic Model AD24-4. EPA. EPA 2006c. EPA 600/R-06/055 Biological Innactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems. Lumalier ADPL-60-8. EPA. ESCOMBE, A. R., MOORE, D. A. J., GILMAN, R. H., NAVINCOPA, M., TICONA, E., MITCHELL, B., NOAKES, C., MARTINEZ, C., SHEEN, P., RAMIREZ, R., QUINO, W., GONZALEZ, A., FRIEDLAND, J. S. & EVANS, C. A. 2009. Upper-Room Ultraviolet Light and Negative Air Ionization to Prevent Tuberculosis Transmission. PLoS MEDICINE, 6, 12. FINNEGAN, M. J., PICKERING, C. A. C. & BURGE, P. S. 1984. The sick building syndrome: prevalence studies. British Medical Journal, 289, 3. FISK, W. J., FAULKNER, D., PALONEN, J. & SEPPANEN, O. 2002. Performance and Cost of Particle Air Filtration Technologies. Indoor air, 12, 12. FLETCHER, L. A. 2004. The influence of relative humidity on the UV susceptibility of airborne gram negative bacteria. IUVA News, 6, 7. FLETCHER, L. A., NOAKES, C. J. & BEGGS, C. B. The importance of Bioaerosols in Hospital Infections and the Potential for Control using Germicidal Ultraviolet Irradiation. Proceedings of the 1st seminar on Applied Aerobiology, 2004. FLETCHER, L. A., NOAKES, C. J., BEGGS, C. B., SLEIGH, P. A. & KERR, K. G. 2003. The Ultraviolet Susceptibility of Aerolised Microorganisms and the Role of Photoreactivation. Second international congress of the IUVA. Vienna. FOARDE, K., FRANKE, D., WEBBER, T., HANLEY, J. & OWEN, K. 2006. Biological Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems: Steril-Aire, Inc. Model SE 1 VO with GTS 24 VO Emitter. Technology Report. EPA. FOARDE, K. K. & HANLEY, J. T. 1999. Determine the efficacy of antimicrobial treatments of fibrous air filters. RTI. FRITZE, D. & PUKALL, R. 2001. Reclassification of Bioindicator Strains Bacillus subtilis DSM 675 and Bacillus subtilis DSM 2277 as Bacillus atrophaeus. International Journal of Systematic and Evolutionary Microbiology, 51, 35-37. GILKESON, C. A. & NOAKES, C. J. 2013. Applications of CFD Simulation to Predicting Upper-room UVGI. Photochemistry and Photobiological. GILLIS, H. L. 1973. Photoreactivation and ultraviolet inactivation of Mycobacteria in air. MSc, Georgia Institute of Technology. GOVAN, HUGHES & VANDAMME 1996. Burkholderia cepacia: medical, taxonomic and ecological issues. J. Med. Microbiol, 45, 13. GRANGE, J. M., YATES, M. D. & KANTOR, I. N. D. 1996. Guidelines for speciation within the Mycobacterium tuberculosis complex. Second edition. World Health Organization. GUSTAVSSON, J. 2000. Air Filters and IAQ. Camfil Farr. GUTIERREZ, R. L., BOURGEOUS, K. N., SALVESON, A., MEIR, J. & SLATER, A. 2006. Microwave UV: A new wave of tertiary disinfection. WEFTEC, 12. HARSTAD, J., DECKER, H. M. & WEDUM, A. G. 1954. Use of ultraviolet irradiation in a room air conditioner for removal of bacteria. Am Ind Hyg Assoc J, 2, 4. HEREAUS NOBLELIGHT 2007. Ultraviolet lamps for disinfection and oxidation. HM GOVERNMENT 2011. Carbon Plan. HO, C. K. 2009a. Evaluation of the reflection and refraction in simulations of UV disinfection using the discrete ordinates radiation model. Water Science and Technology, 59, 8. HO, C. K. 2009b. Radiation Dose Modeling in Fluent. WEF Disinfection 2009 Workshop: Modeling UV Disinfection using CFD. University of North Carolina (UNC): Sandia National Laboratories. HO, Y. S., ADROUB, S. A. & ALEISA, F. 2012. Complete Genome Sequence of Mycobacterium fortuitum subsp. fortuitum Type Strain DSM46621. Journal of Bacteriology, 194, 2. HODGSON, A. T., DESTAILLATS, H., HOTCHI, T. & FISK, W. J. 2008. Benefits and technological challenges in the implementation of TiO2-based ultraviolet photocatalytic oxidation (UVPCO) air cleaners. Indoor air 2008. Copenhagen, Denmark. HODGSON, A. T., SULLIVAN, D. P. & FISK, W. J. 2005. Parametric Evaluation of an Innovative Ultra-violet photocatalytic oxidation (UVPCO) air cleaning technology for indoor applications. Lawrence Berkeley National Laboratory. IEA 2010. Energy Performance Certification of Buildings: A policy tool to improve energy efficiency. Paris: International Energy Agency. IMOBERDORF, G. E., TAGHIPOUR, F. & MOHSENI, M. 2008. Radiation field modeling of multi-lamp, homogeneous photoreactors. Journal of Photochemistry and Photobiology A: Chemistry, 198, 10. IRAZOQUI, H. A., CERDA, J. & CASSANO, A. E. 1973. Radiation Profiles in an Empty Annular Photoreactor with a Source of Finite Spatial Dimensions. AIChE Journal, 19, 8. IRAZOQUI, H. A., CERDA, J. & CASSANO, A. E. 1976. The Radiation Field for the Point and Line Source Approximations and the Three-dimensional Source Models: Applications to Photoreactions. The Chemical Engineering Journal, 11, 11. IUVA 2005a. General Guideline for UVGI Air and Surface Disinfection Systems. Ontario, Canada: International Ultraviolet Association. IUVA 2005b. Guideline for the Design and Installation of UVGI In-duct Air Disinfection Systems in New Building Construction. International UV Association. IUVA 2005c. Guideline for the Design and Installation of UVGI In-duct Air Disinfection Systems.: IUVA. IUVA 2005d. Guideline for the Design and Installation of UVGI Unitary Recirculation and Air Disinfection Systems. IUVA. IUVA 2005e. Medium Pressure and Low Pressure wave length spectrum. JENSEN, M. M. 1964. Inactivation of airborne viruses by ultraviolet irradiation. Applied Microbiology, 3. KARLSSON, B. & RIBBING, C. G. 1982. Optical constants and spectral selectivity of stainless steel and its oxides. Journal of Applied Physics, 53, 6340-6346. KE, Q. S., CRAIK, S. A., EL-DIN, M. G. & BOLTON, J. R. 2009. Development of a Protocol for the Determination of the Ultraviolet Sensitivity of Microorganisms Suspended in air. Aerosol Science and Technology, 43, 6. KERR, J. H. & BARRET, T. L. 2010. Atypical Mycobacterial diseases. Military Dermatology Text book. KETHLEY, T. 1979. Feasibility Study of Germicidal UV Lamps for Air Disinfection in Simulated Patient Care Rooms. San Francisco, Ca: American Public Health Association. KIMA, K. Y. & KIM, C. N. 2006a. Airborne microbiological characteristics in public buildings of Korea. Building and Environment, 42, 9. KIMA, K. Y. & KIM, C. N. 2006b. General of airborne bacteria and fungi identified in the public buildings regulated in Korea In: KOREA, G. O. A. B. A. F. I. I. T. P. B. R. I. (ed.). KING, M. F., NOAKES, C. J., SLEIGH, P. A. & CAMARGO-VALERO, M. 2013. Bioaerosol Deposition in Single and Two-bed Hospital Rooms: A Numerical and Experimental Study. Building and Environment, 59, 11. KO, G., FIRST, M. W. & BURGE, H. A. 2000. Influence of relative humidity on particle size and UV sensitivity of serratia marcescens and Mycobacterium bovis BCG aerosols. Tubercle and lung disease, 80, 12. KOLLER, L. R. 1939. Bactericidal Effects of Ultraviolet Radiation Produced by Low Pressure Mercury Vapor Lamps. Journal of Applied Physics, 10, 624-630. KOWALSKI, W. 2009a. Ultraviolet Germicidal Irradiation Handbook, Springer. KOWALSKI, W. 2009b. Ultraviolet Germicidal Irradiation Handbook. 1 ed.: Springer. KOWALSKI, W. J. 2003. Immune building systems technology, New York, Mc Graw Hill. KOWALSKI, W. J. 2009c. Exposure limits for UV irradiation. KOWALSKI, W. J. & BAHNFLETH, W. P. 2000a. Effective UVGI System Design Through Improved Modelling. Transactions - American Society of Heating Refrigerating and Air Conditioning Engineers, 106, 10. KOWALSKI, W. J. & BAHNFLETH, W. P. 2000b. UVGI Design Basics for air and surface disinfection. HPAC engineering, 10. KOWALSKI, W. J., BAHNFLETH, W. P., WITHAM, D. L., SEVERIN, B. F. & WHITTAM, T. S. 2001. Mathematical Modelling of Ultraviolet Germicidal Irradiation for Air Disinfection. Quantitative Microbiology, 2, 22. KUMARI, D. N. P., HAJI, T. C., KEER, V., HAWKEY, P. M., DUNCANSON, V. & FLOWER, E. 1998. Ventilation grilles as a potential source of methicillin-resistant Staphylococcus aureus causing an outbreak in an orthopaedic ward at a district general hospital Journal of Hospital Infection, 39, 7. LAI, K., BURGE, H. A. & FIRST, M. 2004. Size and UV germicidal irradiation susceptibility of Serratia marcescens when aerosolized from different suspending media. Applied and Environmental Microbiology, 70, 8. LAU, J. 2009. Lamp and In-Duct Device Modelling For UVGI Systems Performance Prediction. Doctor of Philosophy, The Pennsylvania State University. LEE, B., BAHNFLETH, W. & AUER, K. Life-Cycle Cost Simulation of In-Duct Ultraviolet Germicidal Irradiation Systems. Proceedings of Building Simulation, 2009 Glasgow, Scotland. LEEDS, U. O. 2010. Fantastic and unique swimming pool [Online]. Leeds. Available: http://sport.leeds.ac.uk/page.asp?section=64&sectionTitle=Swimming+Pool [Accessed 09 August 2011]. LI, C.-S. & KUO, Y.-M. 1992. AIRBORNE CHARACTERIZATION OF FUNGI INDOORS AND OUTDOORS. Aerosol Sci, 23, 4. LIGHTSOURCES. 2009. Products Data Sheets [Online]. Available: http://www.germicidal.com/datasheets.php#ho [Accessed 25 November 2009 2009]. LIU, D. 2004. Numerical simulation of UV Disinfection Reactors: Impact of Fluence Rate Distribution and Turbulence Modelling. PhD, North Carolina State university. LIU, D., WU, C., LINDEN, K. & JOEL, D. 2007. Numerical simulation of UV disinfection reactors: Evaluation of alternative turbulence models. Applied Mathematical Modelling, 31, 16. LUCKIESH, M. 1946. Applications of Germicidal, Erythemal and Infrared Energy. LUCKIESH, M., TAYLOR, A. H., T., K. & ET., L. 1949. Inactivation of molds by germicidal ultraviolet energy. J Franklin Inst, 248, 14. MENDELL, M., FISK, W., KREISS, K., LEVIN, H., ALEXANDER, D., CAIN, W., GIRMAN, J., HINES, C., JENSEN, P., MILTON, D., REXROAT, L. & WALLINGFORD, K. 2002. Improving the Health of Workers in Indoor Environments: Priority Research Needs for a National Occupational Research Agenda. Public Health Matters, 92. MENZIES, D. 1997. SPECIFIC ILLNESSES KNOWN OR SUSPECTED TO BE RELATED TO BUILDINGS. MENZIES, D., PASZTOR, J., RAND, T. & BOURBEAU, J. 1999. Germicidal ultraviolet irradiation in air conditioning systems: effect on office worker health and wellbeing: a pilot study. Occupational and Environmental Medicine, 56, 6. MENZIES, D., POPA, J., HANLEY, J. A., RAND, T. & MILTON, D. K. 2003. Effect of ultraviolet germicidal lights installed in office ventilation systems on workers’ health and wellbeing: double-blind multiple crossover trial. THE LANCET, 362, 7. MILLER, S. C. M., LIPUMA, J. J. & PARKE, J. L. 2002. Culture based and Non-Growth Dependent Detection of the Burkholderia cepacia complex in Soil Environments. Applied and Environmental Microbiology, 68, 9. MILLER, S. L., LINNES, J. & LUONGO, J. 2013. Ultraviolet germicidal irradiation: future directions for air disinfection and building applications. Photochemistry and photobiology, 89, 777-781. MUNAKATA, N. & RUPERT, C. 1975. Effects of DNA-polymerase-defective and recombination-deficient mutations on the ultraviolet sensitivity of Bacillus Subtillis spores. Mutat Res, 27, 13. NAKAMURA, H. 1987. Sterilization efficacy of ultraviolet irradiation on microbial aerosols under dynamic airflow by experimental air conditioning systems. Bull Tokyo Med Dent Univ, 34, 16. NAKAMURA, L. K. 1989. Taxonomic Relationship of Black-Pigmented Bacillus subtilis Strains and a Proposal for Bacillus atrophaeus sp. nov. international journal of systematic Bacteriology, 39, 295-300. NATIONAL AUDIT OFFICE 2004. Improving patient care by reducing the risk of hospital acquired infection: A progress report. Ordered by the House of Commons. NEIDLE, S. 1999. Oxford Handbook of Nucleic Acid Structure, New York, Oxford University Press. NHS. 2008. Smart Solutions For HCAI - Frequently Asked Questions [Online]. 2008. Available: http://www.smartsolutionsforhcai.co.uk/faq.htm 2008]. NICHOLSON, W. L. & GALEANO, B. 2003. UV Resistance of Bacillus anthracis spores Revisited: Validation of Bacillus spores as UV Surrogates for Spores of B. anthracis Sterne. Applied and Environmental Microbiology, 69, 4. NOAKES, C. J., BEGGS, C. B. & SLEIGH, P. A. 2004. Modelling the Performance of Upper Room Ultraviolet Germicidal Irradiation Devices in Ventilated Rooms: Comparison of Analytical and CFD Methods. Indoor and Built Environment, 13, 12. NOAKES, C. J., FLETCHER, L. A., BEGGS, C. B., SLEIGH, P. A. & KERR, K. G. 2003. Development of a numerical model to simulate the biological inactivation of airborne microorganisms in the presence of ultraviolet light. Journal of Aerosol Science, 35, 19. NTC, N. T. C. 2007. Tuberculosis Infection Control: A practical manial for preventing TB. San Francisco: The Francis J. Curry National Tuberculosis Center. PAREEK, V. K. 2004. Light Intensity Distribution in a Phototcatalytics Reactor Using Finite Volume. AIChE Journal, 50, 16. PASTUSZKA, J., PAW, U. K. T., LIS, D. O., WLAZLO, A. & UFIG, K. 1999. Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland. Atmospheric Environment, 34, 10. PECCIA, J. & HERNANDEZ, M. 2001. Photoreactivation in Airborne Mycobacterium parafortuitum. Applied and Environmental Microbiology, 67, 8. PECCIA, J. & HERNANDEZ, M. 2004. UV-Induced Inactivation Rates for Airborne Mycobacterium bovis BCG. Journal of Occupational and Environmental Hygiene, 1, 7. PECCIA, J., WORTH, H. M., MILLER, S. & HERNANDEZ, M. 2001. Effects of relative humidity on the ultraviolet induced inactivation of airborne bacteria. Aerosol Science and Technology, 35, 13. PERAL, J., DOMENECH, X. & OLLIS, D. F. 1997. Heterogeneous Photocatalysis for the purification, decontamination and deodorization of air. J. Chem. Technol. Biotechnol, 23. PEREZ, A. R. & MELLO, K. P. A. A.-D. 2000. SpoIIB Localizes to Active Sites of Septal Biogenesis and Spatially Regulates Septal Thinning during Engulfment in Bacillus subtilis. Journal of Bacteriology, 182, 12. PHILIPS 2005. Effects of air temperature and air velocity on a model TUV36W-PLL. PHILIPS 2007. UV Disinfection - Application Information. In: CATALOGUE, P. (ed.). Philips. PRIVATE HEALTHCARE UK. 2005. MRSA : Statistics in UK and Europe [Online]. Private Healthcare UK. Available: http://www.privatehealth.co.uk/hospitaltreatment/treatment-abroad/mrsa-europe/ [Accessed 12 May 2008 2009]. PURCHAS, D. B. & SUTHERLAND, K. 2002. Handbook of filter media, Elsevier Science. REDLICH, C. A., SPARER, J. & CULLEN, M. R. 1997. Sick-building syndrome. The Lancet, 349, 1013-1016. RENTSCHLER, H. & NAGY, R. 1942. Bactericidal action of ultraviolet radiation on air-borne microorganisms. Journal of Bacteriology, 44, 85-94. RILEY, R., WELLS, W., MILLS, C., NYKA, W. & MCLEAN, R. 1957. Air hygiene in tuberculosis: quantitative studies of infectivity and control in a pilot ward. American review of tuberculosis, 75, 420-431. RILEY, R. L. 1961. AIRBORNE PULMONARY TUBERCULOSIS. Bacteriological Reviews, 25, 243-248. RILEY, R. L. 1974. Airborne Infection. The American Journal of Medicine, 57, 10. RILEY, R. L., KNIGHT, M. & MIDDLEBROOK, G. 1976. Ultraviolet susceptibility of BCG and virulent tubercle bacilli. American Review of Respiratory Disease, 113, 6. ROSTRON, J. 1997. Sick building syndrome : concepts, issues, and practice, London, E & FN Spon. RUTALA, W. A., KATZ, E. B., SHERERTZ, R. J. & JR, F. A. S. 1983. Environmental study of a methicillin-resistant Staphylococcus aureus epidemic in a burn unit. . Journal of Clinical Microbiology, 18, 6. RYAN, K., RAY, C. G., AHMAD, N., DREW, W. L. & PLORDE, J. 2010. Sherris Medical Microbiology, McGraw Hill. RYER, A. 1998. Light Measurement Handbook, Newbury, MA, International Light. SAGRIPANTI, J.-L. & LYTLE, C. D. 2010. Sensitivity to ultraviolet radiation of Lassa, vaccinia, and Ebola viruses dried on surfaces. Arch Virol, 156, 6. SCHAAL, K. P. 1991. Medical and microbiological problems arising from airborne infection in hospitals. Journal of Hospital Infection, 18, 9. SGALARI, G., CAMERA-RODA, G. & SANTARELLI, F. 1998. Discrete Ordinate Method in the Analysis of Radiative Transfer in Photocatalytically Reacting Media. Int. Comm. Heat Mass Transfer, 25, 10. SHARP, G. 1940. The effects of ultraviolet light on bacteria suspended in air. Journal of Bacteriology, 38, 535-547. SHAUGHNESSY, R., LEVETIN, E. & ROGERS, C. 1999. The effects of UV-C on biological contamination of AHUs in a commercial office building: Preliminary results. Indoor Environ, 99, 8. SICHEL, C. 2009. Potential fo advance oxidation processes (AOPs) in disinfection and simultaneous emerging contaminants removal: a review. 5th International Congress on UV technologies. Amsterdam: IUVA. SKOV, P., VALBJØRN, O. & PEDERSEN, B. 1990. Influence of indoor climate on the sick building syndrome in an office environment. The Danish Indoor Climate Study Group. Scand J Work Environ Health, 5, 9. SUMER, B. M. 2013. Lecture Notes on Turbulence. DTU Mekanik, Section for Fluid Mechanics, Coastal & Maritime Engineering Building 403, 2800 Lyngby, Denmark, bms@mek.dtu.dk: Technical University of Denmark. SUTHERLAND, K. 2007a. Chapter 7. Other types of separation equipment. Filters and Filtration Handbook. 5th edition ed.: Elsevier Science. SUTHERLAND, K. 2007b. Filters and Filtration Handbook, Elsevier Science. TANG, J. W., LI, Y., EAMES, I., CHAN, P. K. S. & RIDGWAY, G. L. 2006. Factors involved in the aerosol transmission of infections and control ventilation in healthcare premises. Journal of Hospital Infection, 64, 15. TAYLOR, G. J. S., BANNISTER, G. C. & LEEMING, J. P. 1995. Wound Disinfection With Ultraviolet Radiation. Journal of hospital infection, 30, 9. TEEUW, K. B., VANDENBROUCKE-GRAULS, C. M. & VERHOEF, J. 1994. Airborne gram-negative bacteria and endotoxin in sick building syndrome. A study in Dutch governmental office buildings. Archives of Internal Medicine, 154. TOMPKINS, D. T., LAWNICKI, B. J., ZELTNER, W. A. & ANDERSON, M. A. 2005. Evaluation of Photocatalysis for Gas-Phase Air Cleaning - Part 1: Process, Technical, and Sizing Considerations. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc Transactions, III, 24. TROJAN. 2011. Trojan to Supply Australia's Largest Ultraviolet (UV) Disinfection System [Online]. Available: http://www.trojanuv.com/about/news?id=819 [Accessed 09 August 2011]. TRONVILLE, P. 2006. Global Standard for Filter Testing. ASHRAE Journal, 48, 5. TU, J., YEOH, G. H. & LIU, C. 2007. Computational Fluid Dynamics, Butterworth-Heinemann. UK GOVERNMENT 2008. Climate Change Act 2008. In: GOVERNMENT, U. (ed.). UNIVERSAL, E. 2009. Aeguradoras pagan 5.8 mdp por virus H1N1. El Universal.mx. VANOSDELL, D. & FOARDE, K. 2002. Defining the Effectiveness of UV lamps Installed in Circulating Air Ductwork. Arlington, VA: Air-Conditioning and Refrigeration Technology Institute (ARTI). VERSTEEG, H. K. & MALALASEKERA, W. 2007. An Introduction to Computer Fluid Dynamic: The Finite Volume Method, Harlow, Prentice Hall. W.M. HAYNES, E. 2011. CRC Handbook of Chemistry and Physics, Boca Raton, FL, CRC Press/Taylor and Francis. WALKER, C. & KO, G. 2007. Effect of Ultraviolet Germicidal Irradiation on Viral Aerosols. Environ Sci Technol, 41, 16. WANG, B., MORTAZAVI, R. & HAGHIGHAT, F. 2008. Evaluation of Modelling and Measurement Techniques of Ultraviolet Germicidal Irradiation Effectiveness - Towards the Design of Immune Buildings. Indoor and Built Environment, 18, 12. WARGOCKI, P., WYON, D. P., BAIK, Y. K., CLAUSEN, G. & OLEFANGER, P. 1999. Perceived Air Quality, Sick Building Syndrome (SBS) Symptoms and Productivity in an Office with Two Different Pollution Loads. Indoor air, 9, 20. WARGOCKI, P., WYON, D. P., JANUNSDELL, CLAUSEN, G. & OLEFANGER, P. 2000. The Effects of Outdoor Air Supply Rate in an Office on Perceived Air Quality, Sick Building Syndrome (SBS) Symptoms and Productivity. Indoor air, 10. WEBB, S. J. 1970. Differential, Lethal and Mutagenic Action of 254 nm and 320-400nm Radiation on Semi-Dried Bacteria. Photochemistry and Photobiology, 12, 24. WEINSTEIN, R. A., BRIDGES, C. B., KUEHNERT, M. J. & HALL, C. B. 2003. Transmission of influenza: implications for control in health care settings. Clinical Infectious Diseases, 37, 1094-1101. WHO. 2005. Indoor air pollution and health [Online]. Available: http://www.who.int/mediacentre/factsheets/fs292/en/. WHO 2007. Tuberculosis. World Health Organization. WHO 2009a. Epidemic and Pandemic Alert and Response (EPR) - Influenza A(H1N1) - Update 41. World Health Organization. WHO 2009b. Global Tuberculosis Control 2009. World Health Organization. XU, PECCIA, J., FABIAN, P., MARTYNY, J. W., KEVIN, F., HERNANDEZ, M. & MILLER, S. 2003. Efficacy of ultraviolet germicidal irradiation of upper-room air inactivating airborne bacterial spores and mycobacteria in full-scale studies. Atmospheric Environment, 15. YANG, L., LIU, Z., SHI, J., ZHANG, Y., HU, H. & SHANGGUAN, W. 2007. Degradation of indoor gaseous formaldehyde by hybrid VUV and TiO2/UV processes. Separation and Purification Technology, 54, 8. YOUNG, D. F., MUNSON, B. R., OKIISHI, T. H. & HUEBSCH, W. W. 2010. A Brief Introduction to Fluid Mechanics, Hoboken: Wiley. YU, I. T. S., LI, Y., WONG, T. W., TAM, W., CHAN, A. T., LEE, J. H. W., LEUNG, D. Y. C. & HO, T. 2004. Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus. The NEW ENGLAND JOURNAL of MEDICINE, 350, 9."],"dcterms:accessrights":["public"],"dc:title":["Computational Fluid Dynamic Modeling of In-duct UV Air Sterilisation Systems."],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D"]},"updated_at":"2026-11-18T21:31:10Z"}